14706 lines
608 KiB
Plaintext
14706 lines
608 KiB
Plaintext
|
-- THIS MIB CREATED TO REDUCE DUPLICATION BETWEEN HP LASERJET MIBS
|
||
|
|
||
|
HP-LASERJET-COMMON-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
OBJECT-TYPE FROM RFC1155-SMI
|
||
|
enterprises FROM RFC1155-SMI;
|
||
|
|
||
|
hp OBJECT IDENTIFIER ::= { enterprises 11 }
|
||
|
nm OBJECT IDENTIFIER ::= { hp 2 }
|
||
|
hpsystem OBJECT IDENTIFIER ::= { nm 3 }
|
||
|
net-peripheral OBJECT IDENTIFIER ::= { hpsystem 9 }
|
||
|
netdm OBJECT IDENTIFIER ::= { net-peripheral 4 }
|
||
|
dm OBJECT IDENTIFIER ::= { netdm 2}
|
||
|
|
||
|
DisplayString ::= OCTET STRING
|
||
|
|
||
|
device OBJECT IDENTIFIER ::= { dm 1 }
|
||
|
channel OBJECT IDENTIFIER ::= { device 6 }
|
||
|
channelTable OBJECT IDENTIFIER ::= { channel 3 }
|
||
|
channelEntry OBJECT IDENTIFIER ::= { channelTable 1 }
|
||
|
system OBJECT IDENTIFIER ::= { device 1 }
|
||
|
settings-system OBJECT IDENTIFIER ::= { system 1 }
|
||
|
status-system OBJECT IDENTIFIER ::= { system 2 }
|
||
|
display OBJECT IDENTIFIER ::= { status-system 20 }
|
||
|
display-status OBJECT IDENTIFIER ::= { display 1 }
|
||
|
status-message OBJECT IDENTIFIER ::= { display 2 }
|
||
|
status-message1 OBJECT IDENTIFIER ::= { status-message 1 }
|
||
|
background-message OBJECT IDENTIFIER ::= { status-system 37 }
|
||
|
background-message1 OBJECT IDENTIFIER ::= { background-message 1 }
|
||
|
background-message2 OBJECT IDENTIFIER ::= { background-message 2 }
|
||
|
id OBJECT IDENTIFIER ::= { system 3 }
|
||
|
interface OBJECT IDENTIFIER ::= { system 4 }
|
||
|
at OBJECT IDENTIFIER ::= { interface 2 }
|
||
|
at1 OBJECT IDENTIFIER ::= { at 1 }
|
||
|
simm OBJECT IDENTIFIER ::= { interface 1 }
|
||
|
simm1 OBJECT IDENTIFIER ::= { simm 1 }
|
||
|
simm2 OBJECT IDENTIFIER ::= { simm 2 }
|
||
|
simm3 OBJECT IDENTIFIER ::= { simm 3 }
|
||
|
simm4 OBJECT IDENTIFIER ::= { simm 4 }
|
||
|
simm5 OBJECT IDENTIFIER ::= { simm 5 }
|
||
|
simm6 OBJECT IDENTIFIER ::= { simm 6 }
|
||
|
simm7 OBJECT IDENTIFIER ::= { simm 7 }
|
||
|
simm8 OBJECT IDENTIFIER ::= { simm 8 }
|
||
|
test OBJECT IDENTIFIER ::= { system 5 }
|
||
|
job OBJECT IDENTIFIER ::= { system 6 }
|
||
|
settings-job OBJECT IDENTIFIER ::= { job 1 }
|
||
|
errorlog OBJECT IDENTIFIER ::= { system 11 }
|
||
|
error1 OBJECT IDENTIFIER ::= { errorlog 1 }
|
||
|
error2 OBJECT IDENTIFIER ::= { errorlog 2 }
|
||
|
error3 OBJECT IDENTIFIER ::= { errorlog 3 }
|
||
|
error4 OBJECT IDENTIFIER ::= { errorlog 4 }
|
||
|
error5 OBJECT IDENTIFIER ::= { errorlog 5 }
|
||
|
error6 OBJECT IDENTIFIER ::= { errorlog 6 }
|
||
|
error7 OBJECT IDENTIFIER ::= { errorlog 7 }
|
||
|
error8 OBJECT IDENTIFIER ::= { errorlog 8 }
|
||
|
error9 OBJECT IDENTIFIER ::= { errorlog 9 }
|
||
|
error10 OBJECT IDENTIFIER ::= { errorlog 10 }
|
||
|
error11 OBJECT IDENTIFIER ::= { errorlog 11 }
|
||
|
error12 OBJECT IDENTIFIER ::= { errorlog 12 }
|
||
|
error13 OBJECT IDENTIFIER ::= { errorlog 13 }
|
||
|
error14 OBJECT IDENTIFIER ::= { errorlog 14 }
|
||
|
error15 OBJECT IDENTIFIER ::= { errorlog 15 }
|
||
|
error16 OBJECT IDENTIFIER ::= { errorlog 16 }
|
||
|
error17 OBJECT IDENTIFIER ::= { errorlog 17 }
|
||
|
error18 OBJECT IDENTIFIER ::= { errorlog 18 }
|
||
|
error19 OBJECT IDENTIFIER ::= { errorlog 19 }
|
||
|
error20 OBJECT IDENTIFIER ::= { errorlog 20 }
|
||
|
error21 OBJECT IDENTIFIER ::= { errorlog 21 }
|
||
|
error22 OBJECT IDENTIFIER ::= { errorlog 22 }
|
||
|
error23 OBJECT IDENTIFIER ::= { errorlog 23 }
|
||
|
error24 OBJECT IDENTIFIER ::= { errorlog 24 }
|
||
|
error25 OBJECT IDENTIFIER ::= { errorlog 25 }
|
||
|
error26 OBJECT IDENTIFIER ::= { errorlog 26 }
|
||
|
error27 OBJECT IDENTIFIER ::= { errorlog 27 }
|
||
|
error28 OBJECT IDENTIFIER ::= { errorlog 28 }
|
||
|
error29 OBJECT IDENTIFIER ::= { errorlog 29 }
|
||
|
error30 OBJECT IDENTIFIER ::= { errorlog 30 }
|
||
|
error31 OBJECT IDENTIFIER ::= { errorlog 31 }
|
||
|
error32 OBJECT IDENTIFIER ::= { errorlog 32 }
|
||
|
error33 OBJECT IDENTIFIER ::= { errorlog 33 }
|
||
|
error34 OBJECT IDENTIFIER ::= { errorlog 34 }
|
||
|
error35 OBJECT IDENTIFIER ::= { errorlog 35 }
|
||
|
error36 OBJECT IDENTIFIER ::= { errorlog 36 }
|
||
|
error37 OBJECT IDENTIFIER ::= { errorlog 37 }
|
||
|
error38 OBJECT IDENTIFIER ::= { errorlog 38 }
|
||
|
error39 OBJECT IDENTIFIER ::= { errorlog 39 }
|
||
|
error40 OBJECT IDENTIFIER ::= { errorlog 40 }
|
||
|
error41 OBJECT IDENTIFIER ::= { errorlog 41 }
|
||
|
error42 OBJECT IDENTIFIER ::= { errorlog 42 }
|
||
|
error43 OBJECT IDENTIFIER ::= { errorlog 43 }
|
||
|
error44 OBJECT IDENTIFIER ::= { errorlog 44 }
|
||
|
error45 OBJECT IDENTIFIER ::= { errorlog 45 }
|
||
|
error46 OBJECT IDENTIFIER ::= { errorlog 46 }
|
||
|
error47 OBJECT IDENTIFIER ::= { errorlog 47 }
|
||
|
error48 OBJECT IDENTIFIER ::= { errorlog 48 }
|
||
|
error49 OBJECT IDENTIFIER ::= { errorlog 49 }
|
||
|
error50 OBJECT IDENTIFIER ::= { errorlog 50 }
|
||
|
source-subsystem OBJECT IDENTIFIER ::= { device 2 }
|
||
|
io OBJECT IDENTIFIER ::= { source-subsystem 1 }
|
||
|
settings-io OBJECT IDENTIFIER ::= { io 1 }
|
||
|
status-io OBJECT IDENTIFIER ::= { io 2 }
|
||
|
ports OBJECT IDENTIFIER ::= { io 3 }
|
||
|
port1 OBJECT IDENTIFIER ::= { ports 1 }
|
||
|
parallel OBJECT IDENTIFIER ::= { port1 1 }
|
||
|
processing-subsystem OBJECT IDENTIFIER ::= { device 3 }
|
||
|
pdl OBJECT IDENTIFIER ::= { processing-subsystem 3 }
|
||
|
pdl-esc-p OBJECT IDENTIFIER ::= { pdl 5 }
|
||
|
settings-pdl OBJECT IDENTIFIER ::= { pdl 1 }
|
||
|
pdl-pcl OBJECT IDENTIFIER ::= { pdl 3 }
|
||
|
pdl-postscript OBJECT IDENTIFIER ::= { pdl 4 }
|
||
|
pjl OBJECT IDENTIFIER ::= { processing-subsystem 5 }
|
||
|
destination-subsystem OBJECT IDENTIFIER ::= { device 4 }
|
||
|
print-engine OBJECT IDENTIFIER ::= { destination-subsystem 1 }
|
||
|
settings-prt-eng OBJECT IDENTIFIER ::= { print-engine 1 }
|
||
|
status-prt-eng OBJECT IDENTIFIER ::= { print-engine 2 }
|
||
|
intray OBJECT IDENTIFIER ::= { print-engine 3 }
|
||
|
settings-intray OBJECT IDENTIFIER ::= { intray 1 }
|
||
|
status-intray OBJECT IDENTIFIER ::= { intray 2 }
|
||
|
marking-agent OBJECT IDENTIFIER ::= { print-engine 5 }
|
||
|
settings-marking-agent OBJECT IDENTIFIER ::= { marking-agent 1 }
|
||
|
imaging OBJECT IDENTIFIER ::= { print-engine 6 }
|
||
|
hrm OBJECT IDENTIFIER ::= { dm 3 }
|
||
|
hrStorage OBJECT IDENTIFIER ::= { hrm 2 }
|
||
|
hrStorageTable OBJECT IDENTIFIER ::= { hrStorage 3 }
|
||
|
hrStorageEntry OBJECT IDENTIFIER ::= { hrStorageTable 1 }
|
||
|
hrDevice OBJECT IDENTIFIER ::= { hrm 3 }
|
||
|
hrDeviceTable OBJECT IDENTIFIER ::= { hrDevice 2 }
|
||
|
hrDeviceEntry OBJECT IDENTIFIER ::= { hrDeviceTable 1 }
|
||
|
hrPrinterTable OBJECT IDENTIFIER ::= { hrDevice 5 }
|
||
|
hrPrinterEntry OBJECT IDENTIFIER ::= { hrPrinterTable 1 }
|
||
|
printmib OBJECT IDENTIFIER ::= { dm 2 }
|
||
|
prtGeneral OBJECT IDENTIFIER ::= { printmib 5 }
|
||
|
prtGeneralTable OBJECT IDENTIFIER ::= { prtGeneral 1 }
|
||
|
prtGeneralEntry OBJECT IDENTIFIER ::= { prtGeneralTable 1 }
|
||
|
prtLocalization OBJECT IDENTIFIER ::= { printmib 7 }
|
||
|
prtLocalizationTable OBJECT IDENTIFIER ::= { prtLocalization 1 }
|
||
|
prtLocalizationEntry OBJECT IDENTIFIER ::= { prtLocalizationTable 1 }
|
||
|
prtStorageRefTable OBJECT IDENTIFIER ::= { prtGeneral 2 }
|
||
|
prtStorageRefEntry OBJECT IDENTIFIER ::= { prtStorageRefTable 1 }
|
||
|
prtDeviceRefTable OBJECT IDENTIFIER ::= { prtGeneral 3 }
|
||
|
prtDeviceRefEntry OBJECT IDENTIFIER ::= { prtDeviceRefTable 1 }
|
||
|
prtMarker OBJECT IDENTIFIER ::= { printmib 10 }
|
||
|
prtMarkerTable OBJECT IDENTIFIER ::= { prtMarker 2 }
|
||
|
prtMarkerEntry OBJECT IDENTIFIER ::= { prtMarkerTable 1 }
|
||
|
prtMarkerColorant OBJECT IDENTIFIER ::= { printmib 12 }
|
||
|
prtMarkerColorantTable OBJECT IDENTIFIER ::= { prtMarkerColorant 1 }
|
||
|
prtMarkerColorantEntry OBJECT IDENTIFIER ::= { prtMarkerColorantTable 1 }
|
||
|
prtConsoleDisplayBuffer OBJECT IDENTIFIER ::= { printmib 16 }
|
||
|
prtConsoleDisplayBufferTable OBJECT IDENTIFIER ::= { prtConsoleDisplayBuffer 5 }
|
||
|
prtConsoleDisplayBufferEntry OBJECT IDENTIFIER ::= { prtConsoleDisplayBufferTable 1 }
|
||
|
prtConsoleLights OBJECT IDENTIFIER ::= { printmib 17 }
|
||
|
prtConsoleLightTable OBJECT IDENTIFIER ::= { prtConsoleLights 6 }
|
||
|
prtConsoleLightEntry OBJECT IDENTIFIER ::= { prtConsoleLightTable 1 }
|
||
|
prtAlert OBJECT IDENTIFIER ::= { printmib 18 }
|
||
|
prtAlertTable OBJECT IDENTIFIER ::= { prtAlert 1 }
|
||
|
prtAlertEntry OBJECT IDENTIFIER ::= { prtAlertTable 1 }
|
||
|
phd OBJECT IDENTIFIER ::= { interface 5 }
|
||
|
phd2 OBJECT IDENTIFIER ::= { phd 2 }
|
||
|
phd3 OBJECT IDENTIFIER ::= { phd 3 }
|
||
|
phd4 OBJECT IDENTIFIER ::= { phd 4 }
|
||
|
phd5 OBJECT IDENTIFIER ::= { phd 5 }
|
||
|
phd6 OBJECT IDENTIFIER ::= { phd 6 }
|
||
|
intrays OBJECT IDENTIFIER ::= { intray 3 }
|
||
|
intray1 OBJECT IDENTIFIER ::= { intrays 1 }
|
||
|
outbin OBJECT IDENTIFIER ::= { print-engine 4 }
|
||
|
settings-outbin OBJECT IDENTIFIER ::= { outbin 1 }
|
||
|
outbins OBJECT IDENTIFIER ::= { outbin 3 }
|
||
|
outbin1 OBJECT IDENTIFIER ::= { outbins 1 }
|
||
|
outbin2 OBJECT IDENTIFIER ::= { outbins 2 }
|
||
|
outbin3 OBJECT IDENTIFIER ::= { outbins 3 }
|
||
|
outbin4 OBJECT IDENTIFIER ::= { outbins 4 }
|
||
|
outbin5 OBJECT IDENTIFIER ::= { outbins 5 }
|
||
|
outbin6 OBJECT IDENTIFIER ::= { outbins 6 }
|
||
|
outbin7 OBJECT IDENTIFIER ::= { outbins 7 }
|
||
|
outbin8 OBJECT IDENTIFIER ::= { outbins 8 }
|
||
|
outbin9 OBJECT IDENTIFIER ::= { outbins 9 }
|
||
|
outbin10 OBJECT IDENTIFIER ::= { outbins 10 }
|
||
|
outbin11 OBJECT IDENTIFIER ::= { outbins 11 }
|
||
|
ph OBJECT IDENTIFIER ::= { print-engine 7 }
|
||
|
ph-devices OBJECT IDENTIFIER ::= { ph 3 }
|
||
|
ph2 OBJECT IDENTIFIER ::= { ph-devices 2 }
|
||
|
ph3 OBJECT IDENTIFIER ::= { ph-devices 3 }
|
||
|
ph4 OBJECT IDENTIFIER ::= { ph-devices 4 }
|
||
|
ph5 OBJECT IDENTIFIER ::= { ph-devices 5 }
|
||
|
ph6 OBJECT IDENTIFIER ::= { ph-devices 6 }
|
||
|
print-media OBJECT IDENTIFIER ::= { print-engine 8 }
|
||
|
settings-print-media OBJECT IDENTIFIER ::= { print-media 1 }
|
||
|
media-info OBJECT IDENTIFIER ::= { print-media 3 }
|
||
|
media1 OBJECT IDENTIFIER ::= { media-info 1 }
|
||
|
media2 OBJECT IDENTIFIER ::= { media-info 2 }
|
||
|
media3 OBJECT IDENTIFIER ::= { media-info 3 }
|
||
|
media4 OBJECT IDENTIFIER ::= { media-info 4 }
|
||
|
media5 OBJECT IDENTIFIER ::= { media-info 5 }
|
||
|
media6 OBJECT IDENTIFIER ::= { media-info 6 }
|
||
|
media7 OBJECT IDENTIFIER ::= { media-info 7 }
|
||
|
media8 OBJECT IDENTIFIER ::= { media-info 8 }
|
||
|
media9 OBJECT IDENTIFIER ::= { media-info 9 }
|
||
|
media10 OBJECT IDENTIFIER ::= { media-info 10 }
|
||
|
media11 OBJECT IDENTIFIER ::= { media-info 11 }
|
||
|
media12 OBJECT IDENTIFIER ::= { media-info 12 }
|
||
|
media13 OBJECT IDENTIFIER ::= { media-info 13 }
|
||
|
media14 OBJECT IDENTIFIER ::= { media-info 14 }
|
||
|
media15 OBJECT IDENTIFIER ::= { media-info 15 }
|
||
|
media16 OBJECT IDENTIFIER ::= { media-info 16 }
|
||
|
media17 OBJECT IDENTIFIER ::= { media-info 17 }
|
||
|
prtCover OBJECT IDENTIFIER ::= { printmib 6 }
|
||
|
prtCoverTable OBJECT IDENTIFIER ::= { prtCover 1 }
|
||
|
prtCoverEntry OBJECT IDENTIFIER ::= { prtCoverTable 1 }
|
||
|
prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 }
|
||
|
prtMarkerSuppliesTable OBJECT IDENTIFIER ::= { prtMarkerSupplies 1 }
|
||
|
prtMarkerSuppliesEntry OBJECT IDENTIFIER ::= { prtMarkerSuppliesTable 1 }
|
||
|
prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 }
|
||
|
prtMediaPathTable OBJECT IDENTIFIER ::= { prtMediaPath 4 }
|
||
|
prtMediaPathEntry OBJECT IDENTIFIER ::= { prtMediaPathTable 1 }
|
||
|
file-system OBJECT IDENTIFIER ::= { system 10 }
|
||
|
settings-file-system OBJECT IDENTIFIER ::= { file-system 1 }
|
||
|
status-file-system OBJECT IDENTIFIER ::= { file-system 2 }
|
||
|
file-systems OBJECT IDENTIFIER ::= { file-system 3 }
|
||
|
file-system1 OBJECT IDENTIFIER ::= { file-systems 1 }
|
||
|
file-system2 OBJECT IDENTIFIER ::= { file-systems 2 }
|
||
|
file-system3 OBJECT IDENTIFIER ::= { file-systems 3 }
|
||
|
file-system4 OBJECT IDENTIFIER ::= { file-systems 4 }
|
||
|
resource-manager OBJECT IDENTIFIER ::= { system 12 }
|
||
|
mass-storage-resources OBJECT IDENTIFIER ::= { resource-manager 3 }
|
||
|
hrDiskStorageTable OBJECT IDENTIFIER ::= { hrDevice 6 }
|
||
|
hrDiskStorageEntry OBJECT IDENTIFIER ::= { hrDiskStorageTable 1 }
|
||
|
hrPartitionTable OBJECT IDENTIFIER ::= { hrDevice 7 }
|
||
|
hrPartitionEntry OBJECT IDENTIFIER ::= { hrPartitionTable 1 }
|
||
|
hrFSTable OBJECT IDENTIFIER ::= { hrDevice 8 }
|
||
|
hrFSEntry OBJECT IDENTIFIER ::= { hrFSTable 1 }
|
||
|
mio OBJECT IDENTIFIER ::= { interface 3 }
|
||
|
mio1 OBJECT IDENTIFIER ::= { mio 1 }
|
||
|
mio2 OBJECT IDENTIFIER ::= { mio 2 }
|
||
|
mio3 OBJECT IDENTIFIER ::= { mio 3 }
|
||
|
active-print-jobs OBJECT IDENTIFIER ::= { job 2 }
|
||
|
job-being-parsed OBJECT IDENTIFIER ::= { active-print-jobs 1 }
|
||
|
job-info OBJECT IDENTIFIER ::= { job 5 }
|
||
|
job-info-attribute OBJECT IDENTIFIER ::= { job-info 23 }
|
||
|
status-pdl OBJECT IDENTIFIER ::= { pdl 2 }
|
||
|
jetsend-proc-sub OBJECT IDENTIFIER ::= { processing-subsystem 8 }
|
||
|
settings-jetsend OBJECT IDENTIFIER ::= { jetsend-proc-sub 1 }
|
||
|
jetsend-contact OBJECT IDENTIFIER ::= { jetsend-proc-sub 3 }
|
||
|
settings-jetsend-contact OBJECT IDENTIFIER ::= { jetsend-contact 1 }
|
||
|
held-job OBJECT IDENTIFIER ::= { job 7 }
|
||
|
held-job-info OBJECT IDENTIFIER ::= { held-job 1 }
|
||
|
held-job-control OBJECT IDENTIFIER ::= { held-job 2 }
|
||
|
accounting OBJECT IDENTIFIER ::= { system 16 }
|
||
|
printer-accounting OBJECT IDENTIFIER ::= { accounting 1 }
|
||
|
scanner-accounting OBJECT IDENTIFIER ::= { accounting 2 }
|
||
|
scanned-media-usage OBJECT IDENTIFIER ::= { scanner-accounting 1 }
|
||
|
scanner OBJECT IDENTIFIER ::= { source-subsystem 2 }
|
||
|
settings-scanner OBJECT IDENTIFIER ::= { scanner 1 }
|
||
|
remote-procedure-call OBJECT IDENTIFIER ::= { system 13 }
|
||
|
settings-rpc OBJECT IDENTIFIER ::= { remote-procedure-call 1 }
|
||
|
status-rpc OBJECT IDENTIFIER ::= { remote-procedure-call 2 }
|
||
|
rpc-services OBJECT IDENTIFIER ::= { remote-procedure-call 3 }
|
||
|
mount OBJECT IDENTIFIER ::= { rpc-services 1 }
|
||
|
settings-mount OBJECT IDENTIFIER ::= { mount 1 }
|
||
|
nfs-server OBJECT IDENTIFIER ::= { rpc-services 2 }
|
||
|
settings-nfs-server OBJECT IDENTIFIER ::= { nfs-server 1 }
|
||
|
status-nfs-server OBJECT IDENTIFIER ::= { nfs-server 2 }
|
||
|
rpc-bind OBJECT IDENTIFIER ::= { rpc-services 3 }
|
||
|
settings-rpc-bind OBJECT IDENTIFIER ::= { rpc-bind 1 }
|
||
|
status-rpc-bind OBJECT IDENTIFIER ::= { rpc-bind 2 }
|
||
|
xport-interface OBJECT IDENTIFIER ::= { system 14 }
|
||
|
status-xip OBJECT IDENTIFIER ::= { xport-interface 2 }
|
||
|
prtInterpreter OBJECT IDENTIFIER ::= { printmib 15 }
|
||
|
prtInterpreterTable OBJECT IDENTIFIER ::= { prtInterpreter 1 }
|
||
|
prtInterpreterEntry OBJECT IDENTIFIER ::= { prtInterpreterTable 1 }
|
||
|
simm1-bank OBJECT IDENTIFIER ::= { simm1 6 }
|
||
|
simm1-bank1 OBJECT IDENTIFIER ::= { simm1-bank 1 }
|
||
|
simm1-bank2 OBJECT IDENTIFIER ::= { simm1-bank 2 }
|
||
|
simm2-bank OBJECT IDENTIFIER ::= { simm2 6 }
|
||
|
simm2-bank1 OBJECT IDENTIFIER ::= { simm2-bank 1 }
|
||
|
simm2-bank2 OBJECT IDENTIFIER ::= { simm2-bank 2 }
|
||
|
simm3-bank OBJECT IDENTIFIER ::= { simm3 6 }
|
||
|
simm3-bank1 OBJECT IDENTIFIER ::= { simm3-bank 1 }
|
||
|
simm3-bank2 OBJECT IDENTIFIER ::= { simm3-bank 2 }
|
||
|
mass-storage-block-driver OBJECT IDENTIFIER ::= { system 15 }
|
||
|
settings-mass-storage-bd OBJECT IDENTIFIER ::= { mass-storage-block-driver 1 }
|
||
|
status-mass-storage-bd OBJECT IDENTIFIER ::= { mass-storage-block-driver 2 }
|
||
|
mass-storage-block-drivers OBJECT IDENTIFIER ::= { mass-storage-block-driver 3 }
|
||
|
mass-storage-bd2 OBJECT IDENTIFIER ::= { mass-storage-block-drivers 2 }
|
||
|
settings-msbd2 OBJECT IDENTIFIER ::= { mass-storage-bd2 1 }
|
||
|
spooler OBJECT IDENTIFIER ::= { source-subsystem 4 }
|
||
|
settings-spooler OBJECT IDENTIFIER ::= { spooler 1 }
|
||
|
media-modes OBJECT IDENTIFIER ::= { print-media 4 }
|
||
|
media-mode-details OBJECT IDENTIFIER ::= { print-media 6 }
|
||
|
media-mode1 OBJECT IDENTIFIER ::= { media-mode-details 1 }
|
||
|
media-mode2 OBJECT IDENTIFIER ::= { media-mode-details 2 }
|
||
|
media-mode3 OBJECT IDENTIFIER ::= { media-mode-details 3 }
|
||
|
media-mode4 OBJECT IDENTIFIER ::= { media-mode-details 4 }
|
||
|
media-mode5 OBJECT IDENTIFIER ::= { media-mode-details 5 }
|
||
|
phd1 OBJECT IDENTIFIER ::= { phd 1 }
|
||
|
intray2 OBJECT IDENTIFIER ::= { intrays 2 }
|
||
|
intray3 OBJECT IDENTIFIER ::= { intrays 3 }
|
||
|
intray4 OBJECT IDENTIFIER ::= { intrays 4 }
|
||
|
intray5 OBJECT IDENTIFIER ::= { intrays 5 }
|
||
|
intray6 OBJECT IDENTIFIER ::= { intrays 6 }
|
||
|
intray7 OBJECT IDENTIFIER ::= { intrays 7 }
|
||
|
media-size OBJECT IDENTIFIER ::= { print-media 5 }
|
||
|
prtInput OBJECT IDENTIFIER ::= { printmib 8 }
|
||
|
prtInputTable OBJECT IDENTIFIER ::= { prtInput 2 }
|
||
|
prtInputEntry OBJECT IDENTIFIER ::= { prtInputTable 1 }
|
||
|
prtOutput OBJECT IDENTIFIER ::= { printmib 9 }
|
||
|
prtOutputTable OBJECT IDENTIFIER ::= { prtOutput 2 }
|
||
|
prtOutputEntry OBJECT IDENTIFIER ::= { prtOutputTable 1 }
|
||
|
tables OBJECT IDENTIFIER ::= { device 7 }
|
||
|
channel-table OBJECT IDENTIFIER ::= { tables 2 }
|
||
|
channel-entry OBJECT IDENTIFIER ::= { channel-table 1 }
|
||
|
prtChannel OBJECT IDENTIFIER ::= { printmib 14 }
|
||
|
prtChannelTable OBJECT IDENTIFIER ::= { prtChannel 1 }
|
||
|
prtChannelEntry OBJECT IDENTIFIER ::= { prtChannelTable 1 }
|
||
|
printed-media-usage OBJECT IDENTIFIER ::= { printer-accounting 1 }
|
||
|
|
||
|
localization-language OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEnglish(1),
|
||
|
eFrench(2),
|
||
|
eGerman(3),
|
||
|
eSpanish(4),
|
||
|
eItalian(5),
|
||
|
eSwedish(6),
|
||
|
eDanish(7),
|
||
|
eNorwegian(8),
|
||
|
eDutch(9),
|
||
|
eFinnish(10),
|
||
|
eJapanese(11),
|
||
|
ePortuguese(12),
|
||
|
ePolish(13),
|
||
|
eTurkish(14)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Localization language used by the device for device
|
||
|
generated PML strings, control panel messages, and text
|
||
|
contained in any of the printer generated printed pages.
|
||
|
The order is the same order that is defined in MIO.
|
||
|
Since the MIO values start at zero, one has been added
|
||
|
to each value."
|
||
|
::= { status-system 1 }
|
||
|
|
||
|
not-ready-printer OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Indicates if any of the sub-systems in the printer are
|
||
|
not ready. A sub-system is not ready if the sub-system
|
||
|
is unable to perform its function until some sort of
|
||
|
intervention occurs. If there are no items in the NOT-
|
||
|
READY-PRINTER collection (i.e. no bits are set), then
|
||
|
all printer sub- systems are ready. Each sub-system has
|
||
|
a sub-system specific not ready object. If a sub-system
|
||
|
specific not ready object contains any items, then the
|
||
|
associated item will be in the NOT-READY collection."
|
||
|
::= { status-system 2 }
|
||
|
|
||
|
|
||
|
not-ready-controller OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if the hardware controller sub-system in the
|
||
|
device is not ready. If there are no items in the
|
||
|
collection (i.e. no bits are set), then the hardware
|
||
|
controller sub-system is ready. If there is an item
|
||
|
present, then the item indicates what is causing the
|
||
|
hardware controller sub-system to be not ready. If the
|
||
|
cControllerFailure item is in the collection, then a
|
||
|
hardware error was detected on the main controller PC
|
||
|
board, sometimes called the formatter or the logic
|
||
|
broad. Example controller hardware errors include DRAM
|
||
|
controller failure, clock failure, memory parity error,
|
||
|
and ROM CRC error. The cFirmwareFailure item is in the
|
||
|
collection if a firmware/software error was detected.
|
||
|
Device specific detailed error information can be
|
||
|
retrieved from the error log objects, if the device
|
||
|
supports those objects. The POS will list which device
|
||
|
failures cause each item to be included in the
|
||
|
collection.
|
||
|
Additional information:
|
||
|
A controller failure occurrence will set the
|
||
|
cControllerFailure bit (bit 1). The controller
|
||
|
failures are: 62.X Service, 63 Service, 65 Service,
|
||
|
67 Service, 68 Service, and 68 Error.
|
||
|
A SIMM failure occurrence will set the cSIMMFailure
|
||
|
bit (bit 2). The SIMM failures are 61.X Service,
|
||
|
53-XY-ZZ Error, and 72 Service.
|
||
|
A DISK failure occurrence will set the cATFailure
|
||
|
bit (bit 3). The DISK failure is FS DISK FAILURE."
|
||
|
::= { status-system 3 }
|
||
|
|
||
|
|
||
|
not-idle OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if any of the sub-systems in the device are
|
||
|
not idle. The I/O source sub-system is considered not
|
||
|
idle if there is unprocessed PDL data in the device.
|
||
|
The PDL processing sub-system is considered not idle if
|
||
|
the device is processing a print job. The print engine
|
||
|
destination sub-system is considered not idle if media
|
||
|
is moving (i.e. the device is printing). [other text
|
||
|
here describing what causes the other sub-systems to be
|
||
|
considered not idle]."
|
||
|
::= { status-system 4 }
|
||
|
|
||
|
on-off-line OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOnline(1),
|
||
|
eOffline(2),
|
||
|
eOfflineAtEndOfJob(3)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"To bring the PDL processing sub-system on or off line.
|
||
|
If the device is a printer, then the printer does not
|
||
|
process print job data when the printer is off line.
|
||
|
PML communication persists.
|
||
|
Additional information:
|
||
|
When the printer is in the Offline state,
|
||
|
printing will stop as soon as possible (no more sheets
|
||
|
of media are pulled from input trays). The I/O
|
||
|
is taken offline also.
|
||
|
|
||
|
Setting to eOnline has the following affect:
|
||
|
Printer will immediately go to or remain in the Online
|
||
|
state; <noError> status is returned.
|
||
|
If the printer's current state
|
||
|
is Offline with a pending error condition that
|
||
|
prevents the printer from going to the Online
|
||
|
state, the printer will remain in the Offline state;
|
||
|
<genErr> status is returned
|
||
|
|
||
|
Setting to eOffline has the following affect:
|
||
|
Printer will immediately go to or remain in the
|
||
|
Offline state; <noError> status is returned.
|
||
|
If pages are being printed, those pages will complete
|
||
|
with the printer in the Offline state.
|
||
|
|
||
|
Setting to eOfflineAtEndOfJob has the following
|
||
|
affect:
|
||
|
If not in a job or already in the Offline state, the
|
||
|
printer will immediately go to or remain in the
|
||
|
Offline state; <noError> status is returned.
|
||
|
If in a job and the current state is Online, the
|
||
|
printer will remain in the Online state, with the
|
||
|
value of this object as eOfflineAtEndOfJob, until the
|
||
|
end of the job; <noError> status is returned. At the end of
|
||
|
the job, the printer goes to the Offline state and the
|
||
|
value of this object becomes eOffline.
|
||
|
Setting this object to eOffline or eOnline before the
|
||
|
end of the job causes the action for that value to be
|
||
|
taken immediately."
|
||
|
::= { status-system 5 }
|
||
|
|
||
|
|
||
|
continue OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eInitiateAction(1)
|
||
|
}
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A device can support a class of errors called
|
||
|
continuable errors. When a continuable error is
|
||
|
encountered, the device requires a continue event to
|
||
|
occur before the device will continue operation. One
|
||
|
continue event is setting the CONTINUE object to
|
||
|
eInitiateAction. Devices can support other continue
|
||
|
events, like auto-continue. A continue event causes the
|
||
|
continuable error to be acknowledged, thus allowing the
|
||
|
device to continue. Each device needs to list the
|
||
|
continuable errors. If the device doesn't currently
|
||
|
have an unacknowledged continuable error, the response
|
||
|
will contain <genErr>.
|
||
|
Additional information:
|
||
|
See the CLEARABLE-WARNING and AUTO-CONTINUE objects for the
|
||
|
errors that this object will clear."
|
||
|
::= { status-system 6 }
|
||
|
|
||
|
user-nvram-reset OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eTrue(1)
|
||
|
}
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Setting to eTrue causes all user NVRAM settings to
|
||
|
factory default settings. May also perform POWER-ON-
|
||
|
RESET functionality thus loosing print job data. The
|
||
|
POS will list which objects are effected by a user NVRAM
|
||
|
reset. Some items are NVRAM settings, but not user
|
||
|
controllable, so this action may not cause all of NVRAM
|
||
|
to be reset. Some examples of NVRAM settings that may
|
||
|
not be affected are page count, internally used pen
|
||
|
information, line configuration information, etc.
|
||
|
Additional information:
|
||
|
Setting to eTrue returns the NVRAM items listed
|
||
|
below to their factory default values. Performs
|
||
|
the same function as the 'MENU RESET' function
|
||
|
supported by the control panel except when printer
|
||
|
is in Offline state, setting this OID to eTrue will
|
||
|
not take the printer to the Online state.
|
||
|
DEFAULT-COPIES
|
||
|
DEFAULT-MEDIA-SIZE
|
||
|
DEFAULT-ORIENTATION
|
||
|
DEFAULT-LINES-PER-PAGE
|
||
|
DEFAULT-MANUAL-FEED
|
||
|
DEFAULT-RET
|
||
|
DEFAULT-PRINT-QUALITY
|
||
|
PCL-DEFAULT-FONT-SOURCE
|
||
|
PCL-DEFAULT-FONT-NUMBER
|
||
|
PCL-DEFAULT-FONT-HEIGHT
|
||
|
PCL-DEFAULT-FONT-WIDTH
|
||
|
PCL-DEFAULT-SYMBOL-SET
|
||
|
DEFAULT-VERTICAL-BLACK-RESOLUTION
|
||
|
DEFAULT-HORIZONTAL-BLACK-RESOLUTION
|
||
|
DEFAULT-PDL
|
||
|
CONTEXT-SENSITIVE-PDL-SELECTION
|
||
|
ENERGY-STAR
|
||
|
IO-TIMEOUT
|
||
|
DEFAULT-PAGE-PROTECT
|
||
|
POSTSCRIPT-JAM-RECOVERY (PostScript installed)
|
||
|
POSTSCRIPT-PRINT-ERRORS (PostScript installed)"
|
||
|
::= { status-system 12 }
|
||
|
|
||
|
total-ram-size OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Identifies total amount of RAM, in bytes, available to
|
||
|
the controller for general computing."
|
||
|
::= { status-system 21 }
|
||
|
|
||
|
status-printer OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Indicates if any of the sub-systems in the device in a
|
||
|
warning condition. A warning condition exists if the
|
||
|
sub-system is useable, but not at its highest state of
|
||
|
functionality."
|
||
|
::= { status-system 22 }
|
||
|
|
||
|
status-controller OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if the hardware controller sub-system in a
|
||
|
warning condition."
|
||
|
::= { status-system 23 }
|
||
|
|
||
|
auto-continue OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOff(1),
|
||
|
eOn(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if the device will automatically continue
|
||
|
after encountering a continuable error. If AUTO-
|
||
|
CONTINUE is set to eOn, the device will automatically
|
||
|
generate continue event to acknowledge continuable
|
||
|
errors. If AUTO-CONTINUE is set to eOff, then some
|
||
|
other continue event will have to acknowledge the
|
||
|
continuable error.
|
||
|
Additional information:
|
||
|
If this is set to eOn the device displays an
|
||
|
error message and goes offline for ten seconds. After ten seconds the
|
||
|
printer automatically returns to the online state.
|
||
|
|
||
|
If this is set to eOff then the device displays an error message and
|
||
|
goes offline. It remains offline until the operator presses the GO key or
|
||
|
until the CONTINUE object is set.
|
||
|
|
||
|
If the printer is not idle, the new value may not take effect
|
||
|
until a job boundary is reached. If a get is done on this object before
|
||
|
the job boundary is reached, the value last set will be returned."
|
||
|
::= { status-system 7 }
|
||
|
|
||
|
display-column-size OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates the number of characters displayable on each
|
||
|
row of the printer's display."
|
||
|
::= { display-status 1 }
|
||
|
|
||
|
|
||
|
display-number-of-rows OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates the number of rows displayable on the
|
||
|
printer's display."
|
||
|
::= { display-status 2 }
|
||
|
|
||
|
|
||
|
status-msg-line1-part1 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"First part of the first line of the printer's status
|
||
|
message.
|
||
|
Additional information:
|
||
|
In the Offline state, device only returns
|
||
|
00 OFFLINE and not the actual content of control panel
|
||
|
display."
|
||
|
::= { status-message1 1 }
|
||
|
|
||
|
|
||
|
background-status-msg-line1-part1 OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..16))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The string displayed on the device's front panel in
|
||
|
place of the printer's built-in background status
|
||
|
string. An example built-in background status string is
|
||
|
'00 READY'.
|
||
|
Additional information:
|
||
|
The display size for the LaserJet 4050 Series printers is 2 X 16.
|
||
|
The value of this object and the current value of
|
||
|
BACKGROUND-STATUS-MSG-LINE2-PART1 are displayed
|
||
|
together on the 2-line display, but they must
|
||
|
be set independently. If line 2 has been set, and the
|
||
|
next message to be displayed only requires line 1,
|
||
|
BACKGROUND-STATUS-MSG-LINE2-PART1 must be set to the
|
||
|
null string to clear it.
|
||
|
This object allows a message to be displayed when
|
||
|
it is the highest priority message. Setting this
|
||
|
object does not guarantee the message will be
|
||
|
displayed; and reading it returns the value last
|
||
|
written, not the currently displayed message (use
|
||
|
prtConsoleDisplayBufferText to read the
|
||
|
display).
|
||
|
The priority assigned for displaying this message
|
||
|
is one lower than the READY message. In other words,
|
||
|
the only message that can be replaced by these
|
||
|
objects is the READY message.
|
||
|
To clear the message, write a null string to both
|
||
|
this object and BACKGROUND-STATUS-MSG-LINE2-PART1."
|
||
|
::= { background-message1 1 }
|
||
|
|
||
|
|
||
|
background-status-msg-line2-part1 OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..16))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The string displayed on the device's front panel in
|
||
|
place of the printer's built-in background status
|
||
|
string. An example built-in background status string is
|
||
|
'00 READY'.
|
||
|
Additional information:
|
||
|
See BACKGROUND-STATUS-MSG-LINE1-PART1"
|
||
|
::= { background-message2 1 }
|
||
|
|
||
|
error-log-clear OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eClearErrorLog(1)
|
||
|
}
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Setting this object clears all the entries in the error
|
||
|
log sub-tree.
|
||
|
Additional information:
|
||
|
Setting this object removes all errors that have been
|
||
|
stored in the printer's non-volatile memory."
|
||
|
::= { status-system 38 }
|
||
|
|
||
|
|
||
|
localization-languages-supported OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The list of languages supported by the device. The
|
||
|
languages are primarily, but not limited to, two
|
||
|
character codes from ISO 639, each separated by a comma
|
||
|
character.
|
||
|
Additional information:
|
||
|
This string will always be in the Roman-8 character
|
||
|
set. See prtLocalizationLanguage for details about each language value."
|
||
|
::= { status-system 52 }
|
||
|
|
||
|
|
||
|
localization-countries-supported OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The list of countries supported by the device. The
|
||
|
countries are primarily, but not limited to, two
|
||
|
character codes from ISO 3166, each separated by a comma
|
||
|
character.
|
||
|
Additional information:
|
||
|
This string will always be in the Roman-8 character
|
||
|
set. See prtLocalizationCountry for details about each country value."
|
||
|
::= { status-system 53 }
|
||
|
|
||
|
|
||
|
control-panel-button-press OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eGoButton(1),
|
||
|
eMenuPlusButton(2),
|
||
|
eMenuMinusButton(3),
|
||
|
eItemPlusButton(4),
|
||
|
eItemMinusButton(5),
|
||
|
eValuePlusButton(6),
|
||
|
eValueMinusButton(7),
|
||
|
eSelectButton(8),
|
||
|
eCancelJobButton(9)
|
||
|
}
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Writing this object simulates pressing a button on the
|
||
|
control panel."
|
||
|
::= { status-system 60 }
|
||
|
|
||
|
|
||
|
model-number OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Identifies the device model number as listed in the HP
|
||
|
corporate price list (e.g. C2121A for DeskJet 500C).
|
||
|
The string is as specific as possible. Products should
|
||
|
note in POS if the model number on the CPL changes but
|
||
|
the device reports the previous model number. If the
|
||
|
model number changes based on the installed options, the
|
||
|
POS should indicate if only the base model number is
|
||
|
returned, or if the device senses the installed options
|
||
|
and returns the correct model number. If possible,
|
||
|
encode the model number in a symbol set (like Roman-8)
|
||
|
that matches the ASCII character set and limit the
|
||
|
characters used to ASCII characters.
|
||
|
Additional information:
|
||
|
The value of this object does not change based on
|
||
|
the installed options. The default of this object is the
|
||
|
same on all LaserJet 4050 Series printers."
|
||
|
::= { id 1 }
|
||
|
|
||
|
|
||
|
serial-number OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..10))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Identifies the serial number for the device. If the
|
||
|
SERIAL-NUMBER object is set by the user, then setting
|
||
|
the object does not need to be protected. If the
|
||
|
SERIAL-NUMBER object is set at the factory, then the
|
||
|
SERVICE-PASSWORD object must be set correctly before the
|
||
|
SERIAL-NUMBER object is writable. If this is a writable
|
||
|
object, the POS should indicate the maximum supported
|
||
|
string length. If possible, encode the serial number in
|
||
|
a symbol set (like Roman-8) that matches the ASCII
|
||
|
character set and limit the characters used to ASCII
|
||
|
characters.
|
||
|
Additional information:
|
||
|
This value IS AFFECTED BY NVRAM resets, it is set to the
|
||
|
default value of XXXXXXXXXX, when a NVRAM init is done."
|
||
|
::= { id 3 }
|
||
|
|
||
|
|
||
|
fw-rom-datecode OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Identifies the base system firmware date code. The date
|
||
|
code will be encoded in the yyyymmdd format. There may
|
||
|
be several versions of the base system firmware. The
|
||
|
date code associated with the version of the base system
|
||
|
firmware that is being used is reported. There may be
|
||
|
other date code objects for other specific modules such
|
||
|
as fonts, localization modules, etc.; these other
|
||
|
datecode objects are device specific."
|
||
|
::= { id 5 }
|
||
|
|
||
|
|
||
|
device-location OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"User defined device location. The POS should indicate
|
||
|
the maximum supported string length. If the user
|
||
|
entered string is too long, the device will store as
|
||
|
much as possible and will return the <noError>.
|
||
|
|
||
|
Additional information:
|
||
|
The maximum supported string length is 16
|
||
|
characters. If the user entered string is too long,
|
||
|
the device will store the first 16 characters and will
|
||
|
return the <noError> status."
|
||
|
::= { id 11 }
|
||
|
|
||
|
|
||
|
asset-number OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"User defined asset number. The POS should indicate the
|
||
|
maximum supported string length. If the user entered
|
||
|
string is too long, the device will store as much as
|
||
|
possible and will return the <noError>.
|
||
|
|
||
|
Additional information:
|
||
|
The maximum supported string length is 8
|
||
|
characters. If the user entered string is too long,
|
||
|
the device will store the first 8 characters and will
|
||
|
return the <noError> status."
|
||
|
::= { id 12 }
|
||
|
|
||
|
system-contact OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"User defined string containing the name of the person or
|
||
|
group that is responsible for the device. The POS
|
||
|
should indicate the maximum supported string length. If
|
||
|
the user entered string is too long, the device will
|
||
|
store as much as possible and will return the
|
||
|
<noError>.
|
||
|
Additional information:
|
||
|
User defined system contact. The maximum
|
||
|
supported string length is 16 characters. If the user
|
||
|
entered string is too long, the device will store as
|
||
|
much as possible and will return the
|
||
|
<noError> status."
|
||
|
::= { id 13 }
|
||
|
|
||
|
at1-model-number OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Identifies the AT model number. If the disk was
|
||
|
manufactured by HP, then the model number is the one
|
||
|
listed in the HP corporate price list. If possible,
|
||
|
encode the model number in a symbol set (like Roman-8)
|
||
|
that matches the ASCII character set and limit the
|
||
|
characters used to ASCII characters.
|
||
|
Additional information:
|
||
|
The model number is obtained from the disk
|
||
|
using the IDE (Intelligent Drive Electronics)
|
||
|
Identify command. This objects is only supported
|
||
|
if a disk is installed. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no disk installed.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to perform a Set, EnableTrap, or
|
||
|
DisableTrap on this OID with no disk installed."
|
||
|
::= { at1 1 }
|
||
|
|
||
|
|
||
|
at1-model-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns product information identifying the AT storage
|
||
|
device. Example: C3014A
|
||
|
Additional information:
|
||
|
The product information is obtained from the
|
||
|
disk using the IDE (Intelligent Drive Electronics)
|
||
|
Identify command. This objects is only supported
|
||
|
if a disk is installed. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no disk installed.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to perform a Set, EnableTrap, or
|
||
|
DisableTrap on this OID with no disk installed."
|
||
|
::= { at1 2 }
|
||
|
|
||
|
|
||
|
at1-manufacturing-info OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns information describing the manufacture of this
|
||
|
particular AT. May include serial number and firmware
|
||
|
revision.
|
||
|
Additional information:
|
||
|
Returns the model number, serial number, and
|
||
|
firmware revision of the installed disk. This
|
||
|
information is obtained from the disk using the
|
||
|
IDE (Intelligent Drive Electronics) Identify
|
||
|
command. Example: HP C3014A JP932412W9 K2A4A059.
|
||
|
This objects is only supported if a disk is installed.
|
||
|
Returns <noSuchName> status if
|
||
|
attempting to perform a Get on this OID with no disk
|
||
|
installed.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to perform a Set, EnableTrap, or
|
||
|
DisableTrap on this OID with no disk installed."
|
||
|
::= { at1 3 }
|
||
|
|
||
|
|
||
|
at1-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eDiskDrive(8)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
this particular AT interface. See SIMM1-TYPE for an
|
||
|
explanation of the enumerations.
|
||
|
Additional information:
|
||
|
eEmpty means the device did not detect any AT.
|
||
|
eDiskDrive means the AT contains a disk drive."
|
||
|
::= { at1 4 }
|
||
|
|
||
|
|
||
|
at1-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of the installed
|
||
|
option. See SIMM1-CAPACITY for an explanation of the
|
||
|
meaning of the value of this object.
|
||
|
Additional information:
|
||
|
This object contains the size, in bytes, of
|
||
|
the installed disk option. This objects is only
|
||
|
supported if a disk is installed.
|
||
|
Returns <noSuchName> status if
|
||
|
attempting to perform a Get on this OID with no disk
|
||
|
installed.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to perform a Set, EnableTrap, or
|
||
|
DisableTrap on this OID with no disk installed."
|
||
|
::= { at1 5 }
|
||
|
|
||
|
|
||
|
simm1-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eUnSupported(3),
|
||
|
eReadOnlyMemory(4),
|
||
|
eVolatileRandomAccessMemory(5),
|
||
|
eFlashMemory(7),
|
||
|
eRamRom(9)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
SIMM slot 1.
|
||
|
eEmpty means the device did not detect any option
|
||
|
installed in the interface slot.
|
||
|
eUnknown means the device doesn't recognize the
|
||
|
installed option.
|
||
|
eUnSupported means the device recognizes the installed
|
||
|
option, but does not support the option.
|
||
|
eReadOnlyMemory means the installed option contains
|
||
|
ROM Ics.
|
||
|
eVolatileRandomAccessMemory means the installed option
|
||
|
contains RAM ICs that loose data when the power is
|
||
|
turned off.
|
||
|
eNonVolatileRandomAccessMemory means that the
|
||
|
installed option contains RAM ICs that do not loose data
|
||
|
when the power is turned off.
|
||
|
eFlashMemory means that the installed option contains
|
||
|
a type of non-volatile RAM that needs to be erased
|
||
|
before it can be written.
|
||
|
eDiskDrive means the installed option contains a disk
|
||
|
drive. eRamRom means the installed option contains both
|
||
|
volatile random access memory and read only memory.
|
||
|
eInputPHD means the installed option is an input paper
|
||
|
handling device.
|
||
|
eOutputPHD means the installed option is an output
|
||
|
paper handling device.
|
||
|
eIOCard means the installed option is an I/O card.
|
||
|
Additional information:
|
||
|
This object is used for describing DIMMs instead
|
||
|
of SIMMs on LaserJet 4050 Series. eRamRom is used to denote LaserJet 4050 Series's combo simm."
|
||
|
::= { simm1 4 }
|
||
|
|
||
|
|
||
|
simm1-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of the SIMM
|
||
|
installed in SIMM slot 1. The capacity is dependent on
|
||
|
the type of option, as indicated by the SIMM1-TYPE
|
||
|
object. This object has no meaning if the installed
|
||
|
option type is eUnknown or eReadOnlyMemory. This object
|
||
|
contains the size, in bytes, if the installed option
|
||
|
type is eVolatileRandomAccessMemory,
|
||
|
eNonVolatileRandomAccessMemory, eFlashMemory, or
|
||
|
eDiskDrive. If the type of the installed option is
|
||
|
eRamRom, this object contains the size, in bytes, of the
|
||
|
random access memory. If the type of the installed
|
||
|
option is eInputPHD, the capacity indicates the number
|
||
|
of input trays supported by the installed option. If
|
||
|
the type of the installed option is eOutputPHD, the
|
||
|
capacity indicates the number of output bins supported
|
||
|
by the installed option. If the type of the installed
|
||
|
option is eIOCard, the capacity indicates the number of
|
||
|
logical I/O ports supported by the I/O card.
|
||
|
Additional information:
|
||
|
Returns an indication of the capacity of the
|
||
|
installed option in bytes. This object is not
|
||
|
supported unless the SIMM1-TYPE type is
|
||
|
eVolatileRandomAccessMemory, eRamRom, or eFlashMemory.
|
||
|
For eRamRom only the size of the Ram portion of the SIMM
|
||
|
is returned."
|
||
|
::= { simm1 5 }
|
||
|
|
||
|
|
||
|
simm2-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eUnSupported(3),
|
||
|
eReadOnlyMemory(4),
|
||
|
eVolatileRandomAccessMemory(5),
|
||
|
eFlashMemory(7),
|
||
|
eRamRom(9)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
SIMM slot 2. See SIMM1-TYPE for a description.
|
||
|
Additional information:
|
||
|
This object is used for describing DIMMs instead
|
||
|
of SIMMs on LaserJet 4050 Series. eRamRom is used to denote LaserJet 4050 Series's combo simm."
|
||
|
::= { simm2 4 }
|
||
|
|
||
|
|
||
|
simm2-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of the SIMM
|
||
|
installed in SIMM slot 2. See SIMM1-CAPACITY for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
This object is used for describing DIMMs instead
|
||
|
of SIMMs on LaserJet 4050 Series. Returns an indication of the capacity of the
|
||
|
installed option in bytes. This object is not
|
||
|
supported unless the SIMM2-TYPE type is
|
||
|
eVolatileRandomAccessMemory, eRamRom, or eFlashMemory.
|
||
|
For eRamRom only the size of the Ram portion of the
|
||
|
SIMM is returned."
|
||
|
::= { simm2 5 }
|
||
|
|
||
|
|
||
|
simm3-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eUnSupported(3),
|
||
|
eReadOnlyMemory(4),
|
||
|
eVolatileRandomAccessMemory(5),
|
||
|
eFlashMemory(7),
|
||
|
eRamRom(9)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
SIMM slot 3. See SIMM1-TYPE for a description."
|
||
|
::= { simm3 4 }
|
||
|
|
||
|
|
||
|
simm3-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of the SIMM
|
||
|
installed in SIMM slot 3. See SIMM1-CAPACITY for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
This object is used for describing DIMMs instead
|
||
|
of SIMMs on LaserJet 4050 Series. Returns an indication of the capacity of the
|
||
|
installed option in bytes. This object is not
|
||
|
supported unless the SIMM3-TYPE type is
|
||
|
eVolatileRandomAccessMemory, eRamRom, or eFlashMemory.
|
||
|
For eRamRom only the size of the Ram portion of the
|
||
|
simm is returned."
|
||
|
::= { simm3 5 }
|
||
|
|
||
|
simm4-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eUnSupported(3),
|
||
|
eReadOnlyMemory(4),
|
||
|
eVolatileRandomAccessMemory(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
SIMM slot 4. See SIMM1-TYPE for a description."
|
||
|
::= { simm4 4 }
|
||
|
|
||
|
|
||
|
simm4-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of the SIMM
|
||
|
installed in SIMM slot 4. See SIMM1-CAPACITY for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
Returns an indication of the capacity of the
|
||
|
installed option in bytes. This object is not
|
||
|
supported unless the SIMM4-TYPE type is
|
||
|
eVolatileRandomAccessMemory."
|
||
|
::= { simm4 5 }
|
||
|
|
||
|
simm5-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eUnSupported(3),
|
||
|
eReadOnlyMemory(4),
|
||
|
eVolatileRandomAccessMemory(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
SIMM slot 5. See SIMM1-TYPE for a description."
|
||
|
::= { simm5 4 }
|
||
|
|
||
|
|
||
|
simm5-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of the SIMM
|
||
|
installed in SIMM slot 5. See SIMM1-CAPACITY for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
Returns an indication of the capacity of the
|
||
|
installed option in bytes. This object is not
|
||
|
supported unless the SIMM5-TYPE type is
|
||
|
eVolatileRandomAccessMemory."
|
||
|
::= { simm5 5 }
|
||
|
|
||
|
|
||
|
simm6-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eUnSupported(3),
|
||
|
eReadOnlyMemory(4),
|
||
|
eVolatileRandomAccessMemory(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
SIMM slot 6. See SIMM1-TYPE for a description."
|
||
|
::= { simm6 4 }
|
||
|
|
||
|
|
||
|
simm6-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of the SIMM
|
||
|
installed in SIMM slot 6. See SIMM1-CAPACITY for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
Returns an indication of the capacity of the
|
||
|
installed option in bytes. This object is not
|
||
|
supported unless the SIMM6-TYPE type is
|
||
|
eVolatileRandomAccessMemory."
|
||
|
::= { simm6 5 }
|
||
|
|
||
|
|
||
|
simm7-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eUnSupported(3),
|
||
|
eReadOnlyMemory(4),
|
||
|
eVolatileRandomAccessMemory(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
SIMM slot 7. See SIMM1-TYPE for a description."
|
||
|
::= { simm7 4 }
|
||
|
|
||
|
|
||
|
simm7-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of the SIMM
|
||
|
installed in SIMM slot 7. See SIMM1-CAPACITY for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
Returns an indication of the capacity of the
|
||
|
installed option in bytes. This object is not
|
||
|
supported unless the SIMM7-TYPE type is
|
||
|
eVolatileRandomAccessMemory."
|
||
|
::= { simm7 5 }
|
||
|
|
||
|
|
||
|
simm8-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eUnSupported(3),
|
||
|
eReadOnlyMemory(4),
|
||
|
eVolatileRandomAccessMemory(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
SIMM slot 8. See SIMM1-TYPE for a description."
|
||
|
::= { simm8 4 }
|
||
|
|
||
|
|
||
|
simm8-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of the SIMM
|
||
|
installed in SIMM slot 8. See SIMM1-CAPACITY for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
Returns an indication of the capacity of the
|
||
|
installed option in bytes. This object is not
|
||
|
supported unless the SIMM8-TYPE type is
|
||
|
eVolatileRandomAccessMemory."
|
||
|
::= { simm8 5 }
|
||
|
|
||
|
self-test OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eNotInASelfTest(1),
|
||
|
eNonDestructiveSelfTest(4)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Writing this object allows a device self test to be
|
||
|
started. Reading this object provides an indication
|
||
|
what self-test is currently executing, if any. Actual
|
||
|
self-test operation is device specific. A self test may
|
||
|
not be allowed at any arbitrary time. If the device
|
||
|
supports the requested self test, but can not start the
|
||
|
execution of the self test when requested, the device
|
||
|
will respond with <genErr>. If
|
||
|
a non-destructive self test is being started, the device
|
||
|
will generate a response before the self test is
|
||
|
completed.
|
||
|
RECOMMENDATION: If the device is ready (i.e. the NOT-
|
||
|
READY-PRINTER object does not contain any items, except
|
||
|
maybe being off-line) and is idle (i.e. the NOT-IDLE
|
||
|
object does not contain any items), this request should
|
||
|
always succeed. This provides a mechanism for driver
|
||
|
writers to always determine if the action will succeed
|
||
|
or not.
|
||
|
Additional information:
|
||
|
The eNonDestructiveSelfTest performs limited
|
||
|
testing on the printer and its attached paper handling
|
||
|
devices. After the self-test is complete a
|
||
|
configuration page is printed. The recommended
|
||
|
way to cause a configuration page to be printed is to
|
||
|
use the PRINT-INTERNAL-PAGE object.
|
||
|
|
||
|
Setting this object to eNonDestructiveSelfTest results in a status of <noError>
|
||
|
and a value of eNonDestructiveSelfTest being returned.
|
||
|
If the printer is not idle (whether printing an external job or printing
|
||
|
an internal page), this action will be delayed until the next job boundary.
|
||
|
|
||
|
See the PRINT-INTERNAL-PAGE object for more details."
|
||
|
::= { test 1 }
|
||
|
|
||
|
|
||
|
print-internal-page OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eNotPrintingAnInternalPage(1),
|
||
|
ePrintingAnUnknownInternalPage(2),
|
||
|
eDeviceDemoPage1ConfigurationPage(3),
|
||
|
eDeviceDemoPage5ErrorLog(7),
|
||
|
eDeviceDemoPage6FileSystemDirectoryListing(8),
|
||
|
eDeviceDemoPage7MenuMap(9),
|
||
|
eDeviceUsagePage(10),
|
||
|
ePCLFontList1(350),
|
||
|
ePSFontList(450)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Writing this object to a value other than
|
||
|
eNotPrintingAnInternalPage causes the device to attempt
|
||
|
to print an internally generated page. Reading this
|
||
|
object provides an indication what internally generated
|
||
|
page is currently being printed, if any. The actual
|
||
|
page is device specific. Some devices may support
|
||
|
continuously printing an internally generated page.
|
||
|
Setting this object to eNotPrintingAnInternalPage
|
||
|
terminates continuously printing internally generated
|
||
|
pages. An internally generated page may not be allowed
|
||
|
to be printed at any arbitrary time; under what
|
||
|
conditions it will succeed or fail is device specific.
|
||
|
If the device supports the requested page, but can not
|
||
|
start printing the page when requested, the device will
|
||
|
respond with <genErr>.
|
||
|
RECOMMENDATION: If the device is ready (i.e. the NOT-
|
||
|
READY-PRINTER object does not contain any items, except
|
||
|
maybe being off-line) and is idle (i.e. the NOT-IDLE
|
||
|
object does not contain any items), this request should
|
||
|
always succeed. This provides a mechanism for driver
|
||
|
writers to always determine if the action will succeed
|
||
|
or not.
|
||
|
Additional information:
|
||
|
Previous products used
|
||
|
ePCLDemoPage1ConfigurationPage(300) for the
|
||
|
Configuration or Self Test page. This product uses
|
||
|
eDeviceDemoPage1ConfigurationPage(3).
|
||
|
|
||
|
LaserJet 4050 Series does not support continuously printing a demo page.
|
||
|
|
||
|
When this object is set to a valid value, the status returned is <noError>
|
||
|
and the value returned is ePrintingAnUnknownInternalPage. If the printer
|
||
|
is idle, the page will be printed immediately. If the printer is
|
||
|
currently printing another job, the internal page requested will not print
|
||
|
until that job is finished.
|
||
|
|
||
|
Setting this object to a valid value causes the
|
||
|
desired page to be formatted and put in the printer's
|
||
|
print queue. While the page is being formatted a get on this object will
|
||
|
return the value ePrintingAnUnknownInternalPage. Once the page (or pages)
|
||
|
is finished being formatted, this object returns a value of
|
||
|
eNotPrintingAnInternalPage, even though the page may not have finished
|
||
|
being printed.
|
||
|
|
||
|
Setting this object multiple times will queue up the requests, but only
|
||
|
a limited number will be queued. Once the queue is full, additional
|
||
|
requests will be ignored."
|
||
|
::= { test 2 }
|
||
|
|
||
|
|
||
|
clearable-warning OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOn(2),
|
||
|
eJob(3)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or controls how the device will track clearable
|
||
|
warnings. A clearable warning indicates a transient
|
||
|
event in the device. The device will continue after the
|
||
|
transient event occurs. If CLEARABLE-WARNING is eOff,
|
||
|
the device does not track clearable warnings. If
|
||
|
CLEARABLE-WARNING is eOn, all clearable warnings will be
|
||
|
tracked until cleared (acknowledged). If CLEARABLE-
|
||
|
WARNING is eJob, a clearable warning generated due to an
|
||
|
event that occurs because of the print job being
|
||
|
processed will be automatically cleared when the device
|
||
|
has finished processing the job. Example clearable
|
||
|
warning events include the device altering resolution or
|
||
|
page protection due to memory constraints. The POS will
|
||
|
document what transient events are treated as clearable
|
||
|
warnings.
|
||
|
Additional information:
|
||
|
If set to eOn, the warning is displayed until the GO key
|
||
|
is pressed or the CONTINUE object is set.
|
||
|
|
||
|
If set to eJob, the warning is displayed until the end of the job in which
|
||
|
it was generated."
|
||
|
::= { settings-job 1 }
|
||
|
|
||
|
|
||
|
cancel-job OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..32767)
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Cancels the print job whose ID matches the value written
|
||
|
to the CANCEL-JOB object. The host first learns the job
|
||
|
ID using the CURRENT-JOB-PARSING-ID command. If the
|
||
|
printer has completely processed the job, the printer
|
||
|
responds with <badValue>. If the
|
||
|
value of the CURRENT-JOB-PARSING-ID is smaller than the
|
||
|
value written to the CANCEL-JOB object, then the printer
|
||
|
responds with <badValue>. When
|
||
|
read, returns the value of the last job ID what was
|
||
|
canceled, or -1 to indicate no job has been canceled.
|
||
|
Additional information:
|
||
|
If the value written matches the ID of a job that is
|
||
|
currently being canceled (for any reason),
|
||
|
the printer responds with <noError>.
|
||
|
LaserJet 4050 Series uses job ID's in the range of 0..32767.
|
||
|
Because the ID number can wrap to zero,
|
||
|
CURRENT-JOB-PARSING-ID may be smaller than the value
|
||
|
written to this object; when this occurs, no error
|
||
|
will result as long as the ID is for a currently
|
||
|
processing job. This object is write only, so the
|
||
|
comment in the general description stating the
|
||
|
job ID or -1 will be returned on a read does not
|
||
|
apply."
|
||
|
::= { settings-job 2 }
|
||
|
|
||
|
|
||
|
error1-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error 1
|
||
|
occurred. Example time stamps include the actual time
|
||
|
the error occurred (in seconds since Jan. 1, 1970), and
|
||
|
the total engine page count. The device POS documents
|
||
|
the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
This item contains the engine
|
||
|
page count when the error occurred.
|
||
|
|
||
|
If there is currently no error entry for this object, a '0' will be returned.
|
||
|
Note that '0' may also be returned when there is a valid error, but a current
|
||
|
page count was unavailable. If ERROR1-CODE object also returns '0', then
|
||
|
an error has not yet been logged for this object.
|
||
|
|
||
|
See ERROR1-CODE for an explanation of the order used for storing errors."
|
||
|
::= { error1 1 }
|
||
|
|
||
|
|
||
|
error1-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
Returns a device specific error code.
|
||
|
If the error code returned is '0', then the printer has not yet logged an
|
||
|
error for this object.
|
||
|
When the maximum number of errors is reached (30 on LaserJet 4050 Series printers), and
|
||
|
a new error occurs, the error in ERROR1-CODE will be replaced by the
|
||
|
one in ERROR2-CODE, and so on until the last error object will be given
|
||
|
the value of the new error.
|
||
|
|
||
|
The error number is returned in the upper 16 bits.
|
||
|
If it is 68, 69, 79, or 80, then the sub code is returned in the lower
|
||
|
16 bits (eg. 68 001C, where the subcode is already a hexadecimal value).
|
||
|
If the error number is any other number, then the 1st sub code (XX)
|
||
|
will be in bits 15-8 and the 2nd sub code (YY) will be in bits 7-0 (eg.
|
||
|
55.04.02) where XX=04 and YY=02).
|
||
|
|
||
|
Example: If the error is 68 001A, then the value returned will be 4456474.
|
||
|
To break it down: 4456474 = 0x0044001A
|
||
|
The upper 16 bits: 0x0044 = 68
|
||
|
The lower 16 bits: 0x001A = 001A
|
||
|
Which is the error: 68 001A
|
||
|
|
||
|
Example: If the error is 55.04.241, then the error code will be 3605745.
|
||
|
To break it down: 3605745 = 0x003704F1
|
||
|
The upper 16 bits: 0x0037 = 55
|
||
|
The upper byte of the lower 16 bits: 0x04 = 04
|
||
|
The lower byte of the lower 16 bits: 0xF1 = 241
|
||
|
Which is the error: 55.04.241"
|
||
|
::= { error1 2 }
|
||
|
|
||
|
|
||
|
error2-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error 2
|
||
|
occurred. Example time stamps include the actual time
|
||
|
the error occurred (in seconds since Jan. 1, 1970), and
|
||
|
the total engine page count. The device POS documents
|
||
|
the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error2 1 }
|
||
|
|
||
|
|
||
|
error2-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error2 2 }
|
||
|
|
||
|
|
||
|
error3-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error 3
|
||
|
occurred. Example time stamps include the actual time
|
||
|
the error occurred (in seconds since Jan. 1, 1970), and
|
||
|
the total engine page count. The device POS documents
|
||
|
the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error3 1 }
|
||
|
|
||
|
|
||
|
error3-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error3 2 }
|
||
|
|
||
|
|
||
|
error4-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error 4
|
||
|
occurred. Example time stamps include the actual time
|
||
|
the error occurred (in seconds since Jan. 1, 1970), and
|
||
|
the total engine page count. The device POS documents
|
||
|
the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error4 1 }
|
||
|
|
||
|
|
||
|
error4-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error4 2 }
|
||
|
|
||
|
|
||
|
error5-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error 5
|
||
|
occurred. Example time stamps include the actual time
|
||
|
the error occurred (in seconds since Jan. 1, 1970), and
|
||
|
the total engine page count. The device POS documents
|
||
|
the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error5 1 }
|
||
|
|
||
|
|
||
|
error5-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error5 2 }
|
||
|
|
||
|
|
||
|
error6-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error 6
|
||
|
occurred. Example time stamps include the actual time
|
||
|
the error occurred (in seconds since Jan. 1, 1970), and
|
||
|
the total engine page count. The device POS documents
|
||
|
the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error6 1 }
|
||
|
|
||
|
|
||
|
error6-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error6 2 }
|
||
|
|
||
|
|
||
|
error7-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error 7
|
||
|
occurred. Example time stamps include the actual time
|
||
|
the error occurred (in seconds since Jan. 1, 1970), and
|
||
|
the total engine page count. The device POS documents
|
||
|
the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error7 1 }
|
||
|
|
||
|
|
||
|
error7-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error7 2 }
|
||
|
|
||
|
|
||
|
error8-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error 8
|
||
|
occurred. Example time stamps include the actual time
|
||
|
the error occurred (in seconds since Jan. 1, 1970), and
|
||
|
the total engine page count. The device POS documents
|
||
|
the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error8 1 }
|
||
|
|
||
|
|
||
|
error8-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error8 2 }
|
||
|
|
||
|
|
||
|
error9-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error 9
|
||
|
occurred. Example time stamps include the actual time
|
||
|
the error occurred (in seconds since Jan. 1, 1970), and
|
||
|
the total engine page count. The device POS documents
|
||
|
the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error9 1 }
|
||
|
|
||
|
|
||
|
error9-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error9 2 }
|
||
|
|
||
|
|
||
|
error10-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
10 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error10 1 }
|
||
|
|
||
|
|
||
|
error10-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error10 2 }
|
||
|
|
||
|
|
||
|
error11-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
11 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error11 1 }
|
||
|
|
||
|
|
||
|
error11-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error11 2 }
|
||
|
|
||
|
|
||
|
error12-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
12 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error12 1 }
|
||
|
|
||
|
|
||
|
error12-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error12 2 }
|
||
|
|
||
|
|
||
|
error13-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
13 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error13 1 }
|
||
|
|
||
|
|
||
|
error13-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error13 2 }
|
||
|
|
||
|
|
||
|
error14-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
14 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error14 1 }
|
||
|
|
||
|
|
||
|
error14-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error14 2 }
|
||
|
|
||
|
|
||
|
error15-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
15 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error15 1 }
|
||
|
|
||
|
|
||
|
error15-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error15 2 }
|
||
|
|
||
|
|
||
|
error16-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
16 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error16 1 }
|
||
|
|
||
|
|
||
|
error16-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error16 2 }
|
||
|
|
||
|
|
||
|
error17-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
17 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error17 1 }
|
||
|
|
||
|
|
||
|
error17-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error17 2 }
|
||
|
|
||
|
|
||
|
error18-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
18 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error18 1 }
|
||
|
|
||
|
|
||
|
error18-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error18 2 }
|
||
|
|
||
|
|
||
|
error19-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
19 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error19 1 }
|
||
|
|
||
|
|
||
|
error19-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error19 2 }
|
||
|
|
||
|
|
||
|
error20-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
20 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error20 1 }
|
||
|
|
||
|
|
||
|
error20-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error20 2 }
|
||
|
|
||
|
|
||
|
error21-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
21 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error21 1 }
|
||
|
|
||
|
|
||
|
error21-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error21 2 }
|
||
|
|
||
|
|
||
|
error22-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
22 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error22 1 }
|
||
|
|
||
|
|
||
|
error22-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error22 2 }
|
||
|
|
||
|
|
||
|
error23-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
23 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error23 1 }
|
||
|
|
||
|
|
||
|
error23-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error23 2 }
|
||
|
|
||
|
|
||
|
error24-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
24 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error24 1 }
|
||
|
|
||
|
|
||
|
error24-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error24 2 }
|
||
|
|
||
|
|
||
|
error25-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
25 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error25 1 }
|
||
|
|
||
|
|
||
|
error25-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error25 2 }
|
||
|
|
||
|
|
||
|
error26-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
26 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error26 1 }
|
||
|
|
||
|
|
||
|
error26-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error26 2 }
|
||
|
|
||
|
|
||
|
error27-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
27 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error27 1 }
|
||
|
|
||
|
|
||
|
error27-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error27 2 }
|
||
|
|
||
|
|
||
|
error28-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
28 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error28 1 }
|
||
|
|
||
|
|
||
|
error28-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error28 2 }
|
||
|
|
||
|
|
||
|
error29-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
29 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error29 1 }
|
||
|
|
||
|
|
||
|
error29-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error29 2 }
|
||
|
|
||
|
|
||
|
error30-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
30 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error30 1 }
|
||
|
|
||
|
|
||
|
error30-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error30 2 }
|
||
|
|
||
|
error31-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains some sort of time stamp indicating when error
|
||
|
31 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error31 1 }
|
||
|
|
||
|
|
||
|
error31-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error31 2 }
|
||
|
|
||
|
error32-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
32 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error32 1 }
|
||
|
|
||
|
|
||
|
error32-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error32 2 }
|
||
|
|
||
|
|
||
|
error33-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
33 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error33 1 }
|
||
|
|
||
|
|
||
|
error33-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error33 2 }
|
||
|
|
||
|
|
||
|
error34-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
34 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error34 1 }
|
||
|
|
||
|
|
||
|
error34-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error34 2 }
|
||
|
|
||
|
|
||
|
error35-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
35 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error35 1 }
|
||
|
|
||
|
|
||
|
error35-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error35 2 }
|
||
|
|
||
|
|
||
|
error36-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
36 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error36 1 }
|
||
|
|
||
|
|
||
|
error36-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error36 2 }
|
||
|
|
||
|
|
||
|
error37-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
37 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error37 1 }
|
||
|
|
||
|
|
||
|
error37-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error37 2 }
|
||
|
|
||
|
|
||
|
error38-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
38 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error38 1 }
|
||
|
|
||
|
|
||
|
error38-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error38 2 }
|
||
|
|
||
|
|
||
|
error39-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
39 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error39 1 }
|
||
|
|
||
|
|
||
|
error39-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error39 2 }
|
||
|
|
||
|
|
||
|
error40-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
40 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error40 1 }
|
||
|
|
||
|
|
||
|
error40-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error40 2 }
|
||
|
|
||
|
|
||
|
error41-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
41 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error41 1 }
|
||
|
|
||
|
|
||
|
error41-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error41 2 }
|
||
|
|
||
|
|
||
|
error42-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
42 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error42 1 }
|
||
|
|
||
|
|
||
|
error42-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error42 2 }
|
||
|
|
||
|
|
||
|
error43-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
43 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error43 1 }
|
||
|
|
||
|
|
||
|
error43-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error43 2 }
|
||
|
|
||
|
|
||
|
error44-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
44 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error44 1 }
|
||
|
|
||
|
|
||
|
error44-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error44 2 }
|
||
|
|
||
|
|
||
|
error45-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
45 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error45 1 }
|
||
|
|
||
|
|
||
|
error45-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error45 2 }
|
||
|
|
||
|
|
||
|
error46-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
46 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error46 1 }
|
||
|
|
||
|
|
||
|
error46-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error46 2 }
|
||
|
|
||
|
|
||
|
error47-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
47 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error47 1 }
|
||
|
|
||
|
|
||
|
error47-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error47 2 }
|
||
|
|
||
|
|
||
|
error48-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
48 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error48 1 }
|
||
|
|
||
|
|
||
|
error48-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error48 2 }
|
||
|
|
||
|
|
||
|
error49-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
49 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error49 1 }
|
||
|
|
||
|
|
||
|
error49-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error49 2 }
|
||
|
|
||
|
|
||
|
error50-time-stamp OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a time stamp indicating when error
|
||
|
50 occurred. Example time stamps include the actual
|
||
|
time the error occurred (in seconds since Jan. 1, 1970),
|
||
|
and the total engine page count. The device POS
|
||
|
documents the meaning of the time stamp.
|
||
|
Additional information:
|
||
|
See ERROR1-TIME-STAMP."
|
||
|
::= { error50 1 }
|
||
|
|
||
|
|
||
|
error50-code OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains a device specific error code. Each device POS
|
||
|
should list what errors are logged to the error log and
|
||
|
the meaning of each supported error code value.
|
||
|
Additional information:
|
||
|
See ERROR1-CODE."
|
||
|
::= { error50 2 }
|
||
|
|
||
|
io-timeout OBJECT-TYPE
|
||
|
SYNTAX INTEGER(5..300)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The amount of time, in seconds, to wait for more print
|
||
|
job data to be received before an I/O timeout occurs.
|
||
|
The I/O channel being timed is the I/O channel that
|
||
|
received the data associated with the current print job.
|
||
|
If an I/O timeout occurs, the PDL processing sub-system
|
||
|
assumes all the data associated with the current print
|
||
|
job has been received, and processes the end of job in
|
||
|
an PDL specific manner. The POS specifies the supported
|
||
|
values.
|
||
|
Additional information:
|
||
|
If an I/O timeout occurs,the PDL processing
|
||
|
sub-system will consider it an end of job condition only
|
||
|
if there is data from another I/O subsystem waiting to be
|
||
|
processed.
|
||
|
The supported values are 5 to 300 seconds.
|
||
|
Setting to a value outside the supported range returns
|
||
|
<noError> status and the
|
||
|
value will be snapped to the nearest supported
|
||
|
value."
|
||
|
::= { settings-io 1 }
|
||
|
|
||
|
|
||
|
io-switch OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eYes(1)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if the device will switch between I/O channels
|
||
|
when a job boundary is encountered and print job data is
|
||
|
available on another I/O channel."
|
||
|
::= { settings-io 2 }
|
||
|
|
||
|
|
||
|
io-buffering OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOff(1),
|
||
|
eOn(2),
|
||
|
eAuto(3)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or controls the manner in which the device
|
||
|
performs I/O data buffering. I/O data buffering allows
|
||
|
additional print job data to be buffered by the I/O sub-
|
||
|
system in an effort to allow the computer sending the
|
||
|
data to perform other tasks and to keep the PDL
|
||
|
processing sub-system busy. eOff, I/O buffering is
|
||
|
disabled. When eOn, I/O buffering is enabled and the
|
||
|
IO-BUFFER-SIZE object controls the amount of memory set
|
||
|
aside for I/O buffer. When eAuto, I/O buffering is
|
||
|
enabled and the I/O buffer size is determined
|
||
|
automatically by the device and the IO-BUFFER-SIZE
|
||
|
object is not used.
|
||
|
Additional information:
|
||
|
In a PCL-only printer, all values may be set at any time.
|
||
|
|
||
|
When there is less than 4M of memory installed, setting this object to eOn
|
||
|
or eAuto will cause <badValue> to be returned.
|
||
|
At exactly 4M of memory, eOn is not a valid setting. At more than 4M
|
||
|
of memory any setting is valid, subject to the conditions listed in the
|
||
|
interactions below."
|
||
|
::= { settings-io 5 }
|
||
|
|
||
|
|
||
|
io-buffer-size OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or configures the amount of memory, in bytes,
|
||
|
dedicated to I/O print job data buffering. Attempting
|
||
|
to set to an unsupported value causes the device to use
|
||
|
the closest supported value. Each device POS should
|
||
|
document the list of supported values.
|
||
|
Additional information:
|
||
|
In LaserJet 4050 Series the minimum supported value is 10K bytes
|
||
|
(10240).
|
||
|
The maximum supported value is dependent on total memory installed
|
||
|
and the amount of memory currently being used by other memory
|
||
|
consumers. Use the MAXIMUM-IO-BUFFERING-MEMORY object to determine
|
||
|
this value.
|
||
|
|
||
|
The following rules determine legal values for this object:
|
||
|
1) Sizes less than 10K bytes will snap to 10K bytes.
|
||
|
2) Sizes between 10K and 100K bytes will be rounded to the nearest 10K.
|
||
|
3) Sizes between 100K bytes and the maximum value allowed will round to
|
||
|
the nearest 100K bytes.
|
||
|
|
||
|
If the value had to be snapped or rounded, <noError>
|
||
|
will be returned along with the actual value that was written.
|
||
|
|
||
|
Attempting to set this object when IO-BUFFERING is eOff will cause a status
|
||
|
of <genErr> to be returned. When IO-BUFFERING is
|
||
|
eOff, reading this object will return a value of zero."
|
||
|
::= { settings-io 6 }
|
||
|
|
||
|
|
||
|
maximum-io-buffering-memory OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object's name is misleading. Returns the maximum
|
||
|
amount of additional memory, in bytes, that can be
|
||
|
dedicated to buffering print job data."
|
||
|
::= { settings-io 7 }
|
||
|
|
||
|
not-ready-source-io OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if the I/O sub-system in the device is not
|
||
|
ready. If there are no items in the collection (i.e. no
|
||
|
bits are set), then the I/O sub-system is ready. If
|
||
|
there is an item present, then the item indicates what
|
||
|
is causing the I/O sub-system to be not ready. If the
|
||
|
I/O sub-system is not ready due to a soft error, the
|
||
|
soft error is considered to be an auto-continuable
|
||
|
error, thus it can be acknowledged by setting the
|
||
|
CONTINUE object to eTrue."
|
||
|
::= { status-io 1 }
|
||
|
|
||
|
|
||
|
status-source-io OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if the I/O sub-system in a warning condition."
|
||
|
::= { status-io 2 }
|
||
|
|
||
|
parallel-speed OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eSlow(1),
|
||
|
eFast(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the maximum parallel I/O port speed.
|
||
|
An eSlow setting causes a 10 us busy pulse per received
|
||
|
byte of data. An eFast setting causes a 1.5 us busy
|
||
|
pulse per received byte of data. In rare cases, setting
|
||
|
this value to eFast can cause the parallel port to no
|
||
|
longer transfer data reliably."
|
||
|
::= { parallel 4 }
|
||
|
|
||
|
|
||
|
parallel-bidirectionality OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUnidirectional(1),
|
||
|
eBidirectional(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes whether the parallel I/O port
|
||
|
supports bidirectional communication."
|
||
|
::= { parallel 5 }
|
||
|
|
||
|
|
||
|
port1-parallel-speed OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eSlow(1),
|
||
|
eFast(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the maximum parallel I/O port speed,
|
||
|
for port 1. This object is only supported if this port
|
||
|
is a parallel port. An eSlow setting causes a 10 us
|
||
|
busy pulse per received byte of data. An eFast setting
|
||
|
causes a 1.5 us busy pulse per received byte of data.
|
||
|
In rare cases, setting this value to eFast can cause the
|
||
|
parallel port to no longer transfer data reliably."
|
||
|
::= { port1 4 }
|
||
|
|
||
|
|
||
|
port1-parallel-bidirectionality OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUnidirectional(1),
|
||
|
eBidirectional(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes whether the parallel I/O port
|
||
|
supports bidirectional communication for port 1. This
|
||
|
object is only supported if this port is a parallel
|
||
|
port.
|
||
|
Additional information:
|
||
|
A get on this object returns the current mode
|
||
|
for the parallel port. Setting this object specifies whether or not
|
||
|
bidirectional communications will be allowed."
|
||
|
::= { port1 5 }
|
||
|
|
||
|
default-orientation OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePortrait(1),
|
||
|
eLandscape(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the default orientation. The list of
|
||
|
supported values should be documented in the device
|
||
|
POS."
|
||
|
::= { settings-pdl 2 }
|
||
|
|
||
|
|
||
|
default-copies OBJECT-TYPE
|
||
|
SYNTAX INTEGER(1..999)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes default copies. Default copies is
|
||
|
the default values used by the PDL to control the number
|
||
|
of copies of each page in the print job that are
|
||
|
printed. The print job can override this value. The
|
||
|
list of supported values should be documented in the
|
||
|
device POS.
|
||
|
Additional information:
|
||
|
The supported values are 1 through 999.
|
||
|
Setting to an unsupported value causes the printer to substitute in a snap
|
||
|
value and to return <noError> status.
|
||
|
The snaps are as follows:
|
||
|
<1 snaps to 1
|
||
|
>999 snaps to 999"
|
||
|
::= { settings-pdl 4 }
|
||
|
|
||
|
|
||
|
form-feed OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eInitiateAction(1)
|
||
|
}
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Instructs the PDL processing sub-system to finishing
|
||
|
processing the current page of the current job. Form
|
||
|
feed is also known as close page or eject page. If the
|
||
|
PDL processing sub-system is in a FORM-FEED-NEEDED
|
||
|
state, this causes the device to flush or finish
|
||
|
processing the current page of the current job. If the
|
||
|
device is not in the FORM-FEED-NEEDED state, an
|
||
|
<genErr> will occur."
|
||
|
::= { settings-pdl 5 }
|
||
|
|
||
|
|
||
|
resource-saving OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOff(1),
|
||
|
eOn(2),
|
||
|
eAuto(3)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes PDL resource saving. Resource saving
|
||
|
stores a PDL's permanent soft resources, like fonts,
|
||
|
even when another PDL is active. Resource saving is
|
||
|
also called environment saving. When eOff, resource
|
||
|
saving is disabled. When ON, resource saving is enabled
|
||
|
and memory is set aside for each PDL based on that PDL's
|
||
|
resource saving memory size object, to store that PDL's
|
||
|
permanent soft resources. When eAuto, resource saving
|
||
|
is enabled and memory space for each installed PDL is
|
||
|
determined automatically. The device POS should
|
||
|
document what values are legal when only one PDL is
|
||
|
installed.
|
||
|
Additional information:
|
||
|
When PCL (including PCL/XL) is the only PDL
|
||
|
installed in LaserJet 4050 Series, eOn is not a legal value. Attempting to set this object to
|
||
|
eOn with a PCL-only printer will result in a status of
|
||
|
<badValue> being returned.
|
||
|
|
||
|
When Postscript is installed and less than 8 Megabytes of RAM are present,
|
||
|
resource saving is not available. The only valid value for this object
|
||
|
is eOff. Attempting to set this object to eOn or eAuto will cause
|
||
|
<badValue> to be returned.
|
||
|
|
||
|
When Postscript and 8 Megabytes or more of RAM are installed, all values
|
||
|
are valid, provided I/O Buffering, Mopying, or Ram Disk have not consumed
|
||
|
the needed memory.
|
||
|
|
||
|
This object is only supported if Postscript is resident in the printer."
|
||
|
::= { settings-pdl 6 }
|
||
|
|
||
|
|
||
|
maximum-resource-saving-memory OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object's name is misleading. This object returns
|
||
|
the maximum amount of additional memory, in bytes, that
|
||
|
can be dedicated to holding PDL permanent soft
|
||
|
resources.
|
||
|
Additional information:
|
||
|
NOTE: The values listed below have not been verified
|
||
|
on LaserJet 4050 Series. The following numbers assume that IO-BUFFERING=eOff;
|
||
|
if IO-BUFFERING<>eOff, the following numbers will be reduced by the value of
|
||
|
IO-BUFFER-SIZE.
|
||
|
|
||
|
Memory for resource saving is allocated in increments of 102400 bytes.
|
||
|
Therefore, for each 1M (1048576 bytes) of memory added to the printer, 102400
|
||
|
bytes are made available to resource saving (and I/O buffering) and 24576
|
||
|
bytes are retained until an additional 102400 byte block can be made
|
||
|
available. The value reported by this object is always rounded down to the
|
||
|
nearest multiple of 102400.
|
||
|
|
||
|
For a PCL-only printer, the value of this object is zero (all resource saving
|
||
|
memory is dedicated to PCL).
|
||
|
|
||
|
If PostScript is installed without a duplex unit, the value of this object is
|
||
|
as follows:
|
||
|
Zero if <7M memory is installed.
|
||
|
1048576 if 7M memory is installed and RESOURCE-SAVING=eOff.
|
||
|
1048576 if 7M memory is installed and RESOURCE-SAVING=eOn (note that this
|
||
|
value will be reduced by the amount of memory allocated to
|
||
|
PCL-RESOURCE-SAVING-MEMORY-SIZE and POSTSCRIPT-RESOURCE-SAVING-MEMORY-SIZE).
|
||
|
819200 if 7M memory is installed and RESOURCE-SAVING=eAuto.
|
||
|
When RESOURCE-SAVING=eAuto, 819200 bytes of each 1M over 7M memory installed
|
||
|
are allocated to PCL and PostScript (409600 each) with the remaining bytes
|
||
|
added to this object.
|
||
|
When RESOURCE-SAVING=eOn or eOff, all bytes over 13M memory installed are
|
||
|
added to this object.
|
||
|
|
||
|
If PostScript is installed with a duplex unit, the value of this object is as
|
||
|
follows:
|
||
|
Zero if <13M memory is installed.
|
||
|
1048576 if 13M memory is installed and RESOURCE-SAVING=eOff.
|
||
|
1048576 if 13M memory is installed and RESOURCE-SAVING=eOn (note that this
|
||
|
value will be reduced by the amount of memory allocated to
|
||
|
PCL-RESOURCE-SAVING-MEMORY-SIZE and POSTSCRIPT-RESOURCE-SAVING-MEMORY-SIZE).
|
||
|
1048576 if 13M memory is installed and RESOURCE-SAVING=eAuto.
|
||
|
When RESOURCE-SAVING=eAuto, 810200 bytes of each 1M over 13M memory installed
|
||
|
are allocated to PCL and PostScript (409600 each) with the remaining bytes
|
||
|
added to this object.
|
||
|
When RESOURCE-SAVING=eOn or eOff, all bytes over 13M memory installed are
|
||
|
added to this object.
|
||
|
|
||
|
The above listed values returned by this object will be reduced by the amount
|
||
|
of memory added to PCL-RESOURCE-SAVING-MEMORY-SIZE and
|
||
|
POSTSCRIPT-RESOURCE-SAVING-MEMORY-SIZE when RESOURCE-SAVING=eOn."
|
||
|
::= { settings-pdl 7 }
|
||
|
|
||
|
|
||
|
default-vertical-black-resolution OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the value of the default vertical
|
||
|
black resolution. The units are dots per inch.
|
||
|
Additional information:
|
||
|
In LaserJet 4050 Series changing this OID also causes
|
||
|
DEFAULT- HORIZONTAL-BLACK RESOLUTION to change.
|
||
|
DEFAULT- HORIZONTAL-BLACK-RESOLUTION and
|
||
|
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
|
||
|
same. The supported values are 300 and 600
|
||
|
for LaserJet 8100 Series and LaserJet 8000 Series, and 300, 600, and 1200 for LaserJet 5000 Series
|
||
|
and LaserJet 4000 Series.
|
||
|
Setting to an unsupported value causes the printer
|
||
|
to substitute in a snap value and
|
||
|
to return <noError> status.
|
||
|
The snap values are as follow:
|
||
|
LaserJet 5000 Series and LaserJet 4000 Series:
|
||
|
n < 450 snaps to 300
|
||
|
450 >= n < 900 snaps to 600
|
||
|
n >= 900 snaps to 1200
|
||
|
LaserJet 8100 Series and LaserJet 8000 Series:
|
||
|
n < 450 snaps to 300
|
||
|
n >= 450 snaps to 600 "
|
||
|
::= { settings-pdl 8 }
|
||
|
|
||
|
|
||
|
default-horizontal-black-resolution OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the value of the default horizontal
|
||
|
black resolution. The units are dots per inch.
|
||
|
Additional information:
|
||
|
In LaserJet 4050 Series changing this object also causes
|
||
|
DEFAULT-VERTICAL-BLACK RESOLUTION to change.
|
||
|
DEFAULT-HORIZONTAL-BLACK-RESOLUTION and
|
||
|
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
|
||
|
same. The supported values are 300 and 600
|
||
|
for LaserJet 8100 Series and LaserJet 8000 Series, and 300, 600, and 1200 for LaserJet 5000 Series
|
||
|
and LaserJet 4000 Series.
|
||
|
Setting to an unsupported value causes the printer
|
||
|
to substitute in a snap value and to
|
||
|
return <noError> status.
|
||
|
The snap values are as follow:
|
||
|
LaserJet 5000 Series and LaserJet 4000 Series:
|
||
|
n < 450 snaps to 300
|
||
|
450 >= n < 900 snaps to 600
|
||
|
n >= 900 snaps to 1200
|
||
|
LaserJet 8100 Series and LaserJet 8000 Series:
|
||
|
n < 450 snaps to 300
|
||
|
n >= 450 snaps to 600 "
|
||
|
::= { settings-pdl 9 }
|
||
|
|
||
|
|
||
|
default-page-protect OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOn(2),
|
||
|
eAuto(3)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the default page protection behavior.
|
||
|
If eOff, the device does not reserve memory for holding
|
||
|
the entire raster form of a processed page. If eOn,
|
||
|
then memory is reserved. If eAuto, the device
|
||
|
determines the amount of memory to reserve.
|
||
|
Additional information:
|
||
|
Setting to eOn causes MET to be more conservative, but
|
||
|
it will not allocate memory to hold an entire
|
||
|
rasterized page."
|
||
|
::= { settings-pdl 10 }
|
||
|
|
||
|
|
||
|
default-lines-per-page OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the default number of lines per page.
|
||
|
The POS indicates the supported values. An unsupported
|
||
|
value causes the printer to use the closest supported
|
||
|
value, causing the printer to return the
|
||
|
<noError>.
|
||
|
Additional information:
|
||
|
The supported values in LaserJet 4050 Series are 5 to 128.
|
||
|
Setting to an unsupported value causes the
|
||
|
the printer to substitute in a snap value and to return
|
||
|
<noError>
|
||
|
status.
|
||
|
The snap values are as follow:
|
||
|
<5 snaps to 5
|
||
|
>128 snaps to 128"
|
||
|
::= { settings-pdl 11 }
|
||
|
|
||
|
|
||
|
default-vmi OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the default vertical motion index.
|
||
|
The unit of measure for VMI is centipoints per line.
|
||
|
The POS indicates the supported values. An unsupported
|
||
|
value causes the printer to use the closest supported
|
||
|
value, causing the printer to return
|
||
|
<noError>."
|
||
|
::= { settings-pdl 12 }
|
||
|
|
||
|
default-media-size OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUSExecutive(1),
|
||
|
eUSLetter(2),
|
||
|
eUSLegal(3),
|
||
|
eROC16K(17),
|
||
|
eJISExecutive(18),
|
||
|
eISOandJISA5(25),
|
||
|
eISOandJISA4(26),
|
||
|
eMonarch(80),
|
||
|
eCommercial10(81),
|
||
|
eInternationalDL(90),
|
||
|
eInternationalC5(91),
|
||
|
eInternationalB5(100),
|
||
|
eCustom(101)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This indicates the default media size. A write of an
|
||
|
unsupported value causes an <badValue>.
|
||
|
Complete list of supported media sizes along
|
||
|
with their dimensions are listed in the ''Media Size
|
||
|
Table'' near the end of this document."
|
||
|
::= { settings-pdl 13 }
|
||
|
|
||
|
|
||
|
cold-reset-media-size OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUSLetter(2),
|
||
|
eISOandJISA4(26)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the media size that is used as the
|
||
|
DEFAULT-MEDIA-SIZE when a cold reset occurs."
|
||
|
::= { settings-pdl 19 }
|
||
|
|
||
|
default-media-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the media name that is used until the
|
||
|
media name is changed by a print job command.
|
||
|
Additional information:
|
||
|
This string must be one of the MEDIAn-NAME
|
||
|
objects. The value of this object is saved across
|
||
|
a power cycle."
|
||
|
::= { settings-pdl 22 }
|
||
|
|
||
|
reprint OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOff(1),
|
||
|
eOn(2),
|
||
|
eAuto(3)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the reprint (jam recovery) setting.
|
||
|
If eOn, then the device will reprint pages jammed pages.
|
||
|
If eOff, the device will not attempt to reprint jammed
|
||
|
pages. If eAuto, a device dependent algorithm (which
|
||
|
should be documented in the POS) will be used to
|
||
|
determine if the page gets reprinted. This object
|
||
|
controls all PDLs, unless a specific PDL supports its
|
||
|
own reprint control mechanism. To date, only PostScript
|
||
|
has a PDL reprint control mechanism.
|
||
|
Additional information:
|
||
|
Setting this object when the printer is not
|
||
|
idle, may cause a status of <noError> to be returned, but
|
||
|
the new value will not take effect until a job boundary
|
||
|
is reached. If a get is done on object before the job
|
||
|
boundary is reached, the value last set will be
|
||
|
returned.
|
||
|
|
||
|
When the value is set to eOff, pages will not be stored
|
||
|
in the printer, and in the event of a paper jam, will
|
||
|
have to be reprinted. When the value is set to eOn,
|
||
|
pages will be stored until delivery, therefore, in the
|
||
|
event of a paper jam, the page will be reprinted.
|
||
|
|
||
|
When the value is set to eAuto, the printer will behave
|
||
|
as though it is eOff when there is less than seven
|
||
|
megabytes of memory installed in the printer. When
|
||
|
additional memory is installed, to total at least seven
|
||
|
megabytes of RAM, the setting of eAuto will behave as
|
||
|
though it was set to eOn."
|
||
|
::= { settings-pdl 36 }
|
||
|
|
||
|
wide-a4 OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOff(1),
|
||
|
eOn(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the wide A4 logical page size
|
||
|
setting. If eOn, then the margins/printable area of A4
|
||
|
paper will be changed to allow 80 10-pitch characters to
|
||
|
be printed on a single line. If eOff then the industry
|
||
|
standard A4 logical page size is used."
|
||
|
::= { settings-pdl 37 }
|
||
|
|
||
|
dark-courier OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOff(1),
|
||
|
eOn(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the dark Courier setting. If eOn,
|
||
|
then the Courier font used will approximate the same
|
||
|
darkness as the LaserJet III printer. If eOff, then the
|
||
|
Courier font used will approximate the same darkness as
|
||
|
the LaserJet 4 printer."
|
||
|
::= { settings-pdl 38 }
|
||
|
|
||
|
default-bits-per-pixel OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Controls the number of levels used (per pixel) when
|
||
|
printing grayscale or color images."
|
||
|
::= { settings-pdl 39 }
|
||
|
|
||
|
pcl-datecode OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This indicates the PCL firmware date code in yyyymmdd
|
||
|
format."
|
||
|
::= { pdl-pcl 1 }
|
||
|
|
||
|
pcl-resource-saving-memory-size OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the amount of resource saving memory
|
||
|
set aside to hold permanent soft PCL resources.
|
||
|
Additional information:
|
||
|
The value returned by this object is the amount of
|
||
|
Resource Saving memory currently dedicated to PCL.
|
||
|
|
||
|
For a PCL-only printer, the value of this object is zero. All memory is
|
||
|
dedicated to PCL, but it is not shown as such.
|
||
|
|
||
|
If Postscript is installed, the default value of this object is as follows:
|
||
|
0 if RESOURCE-SAVING = eOff.
|
||
|
0 if less than 8 Megabytes of RAM is in the printer.
|
||
|
400K bytes if RAM >= 8 Megabytes and RESOURCE-SAVING = eOn.
|
||
|
400K bytes if RAM = 8 Megabytes and RESOURCE-SAVING = eAuto, plus 100K bytes
|
||
|
for each Megabyte of RAM over 8 Megabytes.
|
||
|
|
||
|
If RESOURCE-SAVING=eOn, this object can be used to set the amount of Resource
|
||
|
Saving memory currently dedicated to PCL. The range of values supported by
|
||
|
this object are:
|
||
|
0 bytes (which disables resource saving for PCL)
|
||
|
400K bytes through (400K bytes + MAXIMUM-RESOURCE-SAVING-MEMORY) in
|
||
|
increments of 100K bytes.
|
||
|
If a value is received that is greater than 0 and less than 400K bytes,
|
||
|
it will be snapped to 400K bytes and a status of
|
||
|
<noError> returned.
|
||
|
If an unsupported value greater than 400K bytes is received,
|
||
|
it will be snapped down to the nearest 100K value
|
||
|
and a status of <noError> returned.
|
||
|
|
||
|
Attempting to set this object when RESOURCE-SAVING is eAuto or eOff will
|
||
|
cause a status of <genErr> to be returned."
|
||
|
::= { pdl-pcl 2 }
|
||
|
|
||
|
pcl-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains the name of the PDL. For PCL, the name is
|
||
|
`PCL'."
|
||
|
::= { pdl-pcl 3 }
|
||
|
|
||
|
pcl-version OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains the PDL version."
|
||
|
::= { pdl-pcl 4 }
|
||
|
|
||
|
|
||
|
pcl-total-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Total number of PCL pages printed by the device.
|
||
|
Additional information:
|
||
|
In LaserJet 4050 Series the PCL page count is kept in
|
||
|
NVRAM, and the NVRAM value is updated at least every
|
||
|
10 pages. NOTE: The value returned by this object will
|
||
|
be incremented every page but if power is lost between
|
||
|
NVRAM updates, up to 9 pages of the page count may be
|
||
|
lost. The page count counter will be reset to zero
|
||
|
after 16,777,215 (2^24-1) pages.
|
||
|
The page count is incremented when a sheet of media is pulled from an input
|
||
|
tray. A duplex printed sheet will cause this counter to be incremented by
|
||
|
two."
|
||
|
::= { pdl-pcl 5 }
|
||
|
|
||
|
pcl-default-symbol-set OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eISO60DanishNorwegian(4),
|
||
|
eISO15Italian(9),
|
||
|
eISO88591Latin1ECMA94(14),
|
||
|
eISO11SwedishforNames(19),
|
||
|
eISO6ASCII(21),
|
||
|
eISO4UnitedKingdom(37),
|
||
|
eISO69French(38),
|
||
|
eISO21German(39),
|
||
|
eLegal(53),
|
||
|
eISO88592Latin2ECMA94(78),
|
||
|
eISO17Spanish(83),
|
||
|
ePSMath(173),
|
||
|
eISO88599Latin5ECMA128(174),
|
||
|
eWindows31Latin5(180),
|
||
|
eMicrosoftPublishing(202),
|
||
|
eVenturaMath(205),
|
||
|
eDeskTop(234),
|
||
|
eMath8(269),
|
||
|
eRoman8(277),
|
||
|
eWindows31Latin2(293),
|
||
|
ePC8Turkish(308),
|
||
|
eWindows30Latin1(309),
|
||
|
ePSText(330),
|
||
|
ePC8CodePage437(341),
|
||
|
ePC8DNDanishNorwegian(373),
|
||
|
ePC850Multilingual(405),
|
||
|
eVenturaInternational(426),
|
||
|
eVenturaUS(458),
|
||
|
ePiFont(501),
|
||
|
ePC852Latin2(565),
|
||
|
eWindows31J(619),
|
||
|
eWindows31Latin1(629)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the default PCL symbol set. The
|
||
|
enumeration values match the values supported by the PCL
|
||
|
Symbol Set Code escape sequence, <ESC>*c#R. The binary
|
||
|
representation of the enumerated value is also matches
|
||
|
the PML <SymbolSetValue>.
|
||
|
Additional information:
|
||
|
The eWindows31J enumeration is only supported
|
||
|
if a Japanese font SIMM is installed."
|
||
|
::= { pdl-pcl 11 }
|
||
|
|
||
|
|
||
|
pcl-default-font-height OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the default PCL height. Height is an
|
||
|
approximate measure of the body of the type in
|
||
|
centipoints. A centipoint is 1/7200 inch. Height
|
||
|
applies only to proportional fonts. Point size, in
|
||
|
points, can be converted to font height, in centipoints,
|
||
|
by multiplying the point size by 100. The POS indicates
|
||
|
the supported values. An unsupported value causes the
|
||
|
printer to use the closest supported value, causing the
|
||
|
printer to return <noError>.
|
||
|
''Closest'' means the smallest absolute difference.
|
||
|
Additional information:
|
||
|
Supported values range from 400 to 99975, in
|
||
|
increments of 25 units.
|
||
|
Setting to an unsupported value causes the
|
||
|
printer to substitute in a snap value and to
|
||
|
return <noError> status.
|
||
|
The snap values are as follow:
|
||
|
<=400 snaps to 400
|
||
|
>=99975 snaps to 99975
|
||
|
Unsupported values in the range 400 to 99975 snap
|
||
|
DOWN to the previous supported value
|
||
|
(i.e 25293 snaps to 25275 or 75038 snaps to 75025)."
|
||
|
::= { pdl-pcl 13 }
|
||
|
|
||
|
|
||
|
pcl-default-font-source OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eInternal(1),
|
||
|
ePermanentSoft(2),
|
||
|
eRomSimm1(10),
|
||
|
eRomSimm2(11),
|
||
|
eRomSimm3(12),
|
||
|
eRomSimm4(13)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the value of the default font source
|
||
|
variable in NVRAM."
|
||
|
::= { pdl-pcl 14 }
|
||
|
|
||
|
|
||
|
pcl-default-font-number OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..255)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the value of the default font number
|
||
|
variable in NVRAM. Writing an unsupported value causes
|
||
|
the printer to generate an
|
||
|
<badValue>.
|
||
|
Additional information:
|
||
|
Valid numbers or 0 - 255, but only font numbers that are
|
||
|
included in the PCL FONT LIST are selectable."
|
||
|
::= { pdl-pcl 15 }
|
||
|
|
||
|
|
||
|
pcl-default-font-width OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the default PCL font width. Width is
|
||
|
expressed as the width of a character in centipoints. A
|
||
|
centipoint is 1/7200 inch. Width applies only to fixed
|
||
|
space fonts. Pitch, in character per inch, can be
|
||
|
converted to font width, in centipoints, by dividing
|
||
|
7200 by the pitch. The POS indicates the supported
|
||
|
values. An unsupported value causes the printer to use
|
||
|
the closest supported value, causing the printer to
|
||
|
return <noError>. ''Closest''
|
||
|
means the smallest absolute difference.
|
||
|
Additional information:
|
||
|
Setting to an unsupported value causes the
|
||
|
printer to substitue in a snap value (listed below)
|
||
|
and return <noError> status.
|
||
|
The snap values for pitch are as follow:
|
||
|
<=44 snaps to 44
|
||
|
>=9999 snaps to 9999"
|
||
|
::= { pdl-pcl 16 }
|
||
|
|
||
|
postscript-datecode OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This indicates the PostScript firmware datecode in
|
||
|
yyyymmdd format.
|
||
|
Additional information:
|
||
|
This object is only supported if PostScript
|
||
|
option is installed.
|
||
|
Returns <noSuchName> status if
|
||
|
attempting to perform a Get on this OID with no
|
||
|
PostScript option installed.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to perform a Set, EnableTrap, or
|
||
|
DisableTrap on this OID with no PostScript option
|
||
|
installed."
|
||
|
::= { pdl-postscript 1 }
|
||
|
|
||
|
|
||
|
postscript-resource-saving-memory-size OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the amount of resource saving memory
|
||
|
set aside to hold permanent soft PostScript resources.
|
||
|
Additional information:
|
||
|
The value returned by this object is the amount of
|
||
|
Resource Saving memory currently dedicated to Postscript.
|
||
|
|
||
|
If Postscript is installed, the default value of this object is as follows:
|
||
|
0 if RESOURCE-SAVING = eOff.
|
||
|
0 if less than 8 Megabytes of RAM is in the printer.
|
||
|
400K bytes if RAM >= 8 Megabytes and RESOURCE-SAVING = eOn.
|
||
|
400K bytes if RAM = 8 Megabytes and RESOURCE-SAVING = eAuto, plus 100K bytes
|
||
|
for each Megabyte of RAM over 8 Megabytes.
|
||
|
|
||
|
If RESOURCE-SAVING=eOn, this object can be used to set the amount of Resource
|
||
|
Saving memory currently dedicated to PCL. The range of values supported by
|
||
|
this object are:
|
||
|
0 bytes (which disables resource saving for Postscript)
|
||
|
400K bytes through (400K bytes + MAXIMUM-RESOURCE-SAVING-MEMORY) in
|
||
|
increments of 100K bytes.
|
||
|
If a value is received that is greater than 0 and less than 400K bytes,
|
||
|
it will be snapped to 400K bytes and a status of
|
||
|
<noError> returned.
|
||
|
If an unsupported value greater than 400K bytes is received,
|
||
|
it will be snapped down to the nearest 100K value
|
||
|
and a status of <noError> returned.
|
||
|
|
||
|
Attempting to set this object when RESOURCE-SAVING is eAuto or eOff will
|
||
|
cause a status of <genErr> to be returned."
|
||
|
::= { pdl-postscript 2 }
|
||
|
|
||
|
postscript-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains the name of the PDL. For PostScript, the name
|
||
|
is `PostScript'.
|
||
|
Additional information:
|
||
|
This object is only supported if PostScript
|
||
|
option is installed.
|
||
|
Returns <noSuchName> status if
|
||
|
attempting to perform a Get on this OID with no
|
||
|
PostScript option installed.
|
||
|
Returns an <noSuchName>
|
||
|
status if attempting to perform a Set, EnableTrap, or
|
||
|
DisableTrap on this OID with no PostScript option
|
||
|
installed."
|
||
|
::= { pdl-postscript 3 }
|
||
|
|
||
|
postscript-version OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains the PDL version.
|
||
|
Additional information:
|
||
|
This object is only supported if PostScript
|
||
|
option is installed.
|
||
|
Returns <noSuchName> status if
|
||
|
attempting to perform a Get on this OID with no
|
||
|
PostScript option installed.
|
||
|
Returns an <noSuchName>
|
||
|
status if attempting to perform a Set, EnableTrap, or
|
||
|
DisableTrap on this OID with no PostScript option
|
||
|
installed."
|
||
|
::= { pdl-postscript 4 }
|
||
|
|
||
|
postscript-total-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Total number of PostScript pages printed by the device.
|
||
|
Additional information:
|
||
|
This object is only supported if the PostScript
|
||
|
option is installed.
|
||
|
In LaserJet 4050 Series the count is kept in NVRAM, and the
|
||
|
NVRAM value is updated at least every 10
|
||
|
sheets. NOTE: The value returned by this object will
|
||
|
be incremented every sheet but if power is lost between
|
||
|
NVRAM updates up to 9 sheets of the count may be
|
||
|
lost. The counter will be reset to zero
|
||
|
after 16,777,215 (2^24-1) pages. "
|
||
|
::= { pdl-postscript 5 }
|
||
|
|
||
|
|
||
|
postscript-print-errors OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOff(1),
|
||
|
eOn(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the value of the print PostScript
|
||
|
errors setting. If eOn, PostScript prints an error page
|
||
|
showing the error encountered and the stack at the time
|
||
|
of the error.
|
||
|
Additional information:
|
||
|
This object is only supported if the PostScript
|
||
|
option is installed."
|
||
|
::= { pdl-postscript 11 }
|
||
|
|
||
|
postscript-jam-recovery OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOff(1),
|
||
|
eOn(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the PostScript jam recovery setting.
|
||
|
If eOn, then the device will reprint PostScript pages,
|
||
|
if those pages jam.
|
||
|
Additional information:
|
||
|
This object is only supported if PostScript
|
||
|
option is installed."
|
||
|
::= { pdl-postscript 12 }
|
||
|
|
||
|
esc-p-datecode OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This indicates the ESC-P PDL datecode. The datecode
|
||
|
format is yyyymmdd.
|
||
|
Additional information:
|
||
|
This object is only supported if ESC-P option is
|
||
|
installed.
|
||
|
Returns an <noSuchName> status if
|
||
|
attempting to perform a Get on this OID with no ESC-P
|
||
|
option installed.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to perform a Set, EnableTrap, or
|
||
|
DisableTrap on this OID with no ESC-P option
|
||
|
installed."
|
||
|
::= { pdl-esc-p 1 }
|
||
|
|
||
|
|
||
|
esc-p-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains the name of the PDL. For ESC-P, the name is
|
||
|
`ESC-P'.
|
||
|
Additional information:
|
||
|
This object is only supported if ESC-P option is
|
||
|
installed.
|
||
|
Returns an <noSuchName> status if
|
||
|
attempting to perform a Get on this OID with no ESC-P
|
||
|
option installed.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to perform a Set, EnableTrap, or
|
||
|
DisableTrap on this OID with no ESC-P option
|
||
|
installed."
|
||
|
::= { pdl-esc-p 3 }
|
||
|
|
||
|
|
||
|
esc-p-version OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains the PDL version.
|
||
|
Additional information:
|
||
|
This object is only supported if ESC-P option is
|
||
|
installed.
|
||
|
Returns an <noSuchName> status if
|
||
|
attempting to perform a Get on this OID with no ESC-P
|
||
|
option installed.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to perform a Set, EnableTrap, or
|
||
|
DisableTrap on this OID with no ESC-P option
|
||
|
installed."
|
||
|
::= { pdl-esc-p 4 }
|
||
|
|
||
|
|
||
|
pjl-password OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns PJL password, if the password is not set (zero).
|
||
|
If the password is set, then attempting to retrieve the
|
||
|
password causes an <genErr> to occur
|
||
|
and will return the <NullValue>."
|
||
|
::= { pjl 1 }
|
||
|
|
||
|
not-ready-destination-print-engine OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if the print engine sub-system in the device
|
||
|
is not ready. If there are no items in the collection
|
||
|
(i.e. no bits are set), then the print engine sub-
|
||
|
system is ready. If there is an item present, then the
|
||
|
item indicates what is causing the print engine sub-
|
||
|
system to be not ready. cDoorOpen is in the collection
|
||
|
if one or more access panels are open. If the device
|
||
|
contains more than one access panel, then NOT-READY-
|
||
|
PRINT-ENGINE-DOOR indicates which access panel(s) are
|
||
|
open. cInternalMediaJam is in the collection if one or
|
||
|
more pieces of media are jammed inside the device. If
|
||
|
the media is jammed at an input tray, cTrayMediaJam is
|
||
|
in the collection, and if the device has more than one
|
||
|
input tray, then NOT-READY-MEDIA-JAM-AT-TRAY indicates
|
||
|
which tray has a media jam. If the media is jammed at
|
||
|
an output bin, cBinMediaJam is in the collection, and if
|
||
|
the device has more than one output bin, then NOT-READY-
|
||
|
MEDIA-JAM-AT-BIN indicates which bin has a media jam.
|
||
|
cRequestedMediaUnavailable is in the collection if the
|
||
|
current print job requires media that is not available.
|
||
|
cTrayEmpty is in the collection if the current print job
|
||
|
requires media from an input tray that is empty. If the
|
||
|
device has more than one input tray, then NOT-READY-
|
||
|
TRAY-EMPTY indicates which tray is empty.
|
||
|
cOutputBinFull is in the collection if an output bin is
|
||
|
full. If the device has more than one output bin, then
|
||
|
NOT-READY-BIN-FULL indicates which bin is full.
|
||
|
cManualFeedMedia is in the collection if the device is
|
||
|
waiting for media to manually be fed.
|
||
|
cMarkingAgentMissing is in the collection if a marking
|
||
|
agent (toner cartridge, ink pen, etc.) is missing. If
|
||
|
the device has more than one marking agent, then NOT-
|
||
|
READY-MARKING-AGENT-MISSING indicates which marking
|
||
|
agent is missing. cMarkingAgentOut is in the collection
|
||
|
if the device is not ready due to one or more marking
|
||
|
agents being low or out. If the device has more than
|
||
|
one marking agent, then NOT-READY-MARKING-AGENT-LOW-OR-
|
||
|
OUT indicates which marking agent is low or out.
|
||
|
cIncorrectMarkingAgent is in the collection if the
|
||
|
device detects that an incorrect marking agent is
|
||
|
installed. If the device has more than one marking
|
||
|
agent, then NOT-READY-INCORRECT-MARKING-AGENT indicates
|
||
|
which marking agent location is loaded with the wrong
|
||
|
type of marking agent. cTrayMissing is in the
|
||
|
collection if the device is not ready because one or
|
||
|
more trays are not installed. If the device has more
|
||
|
than one input tray, then NOT-READY-TRAY-MISSING
|
||
|
indicates which tray is missing. cDeviceSpecific is in
|
||
|
the collection if one or more items are in either NOT-
|
||
|
READY-LASER-PRINT-ENGINE or NOT-READY-DESTINATION-
|
||
|
INKJET-PRINT-ENGINE-NOT-READY. cMediaPickMisfeed is in
|
||
|
the collection if the print engine detects the tray is
|
||
|
not empty, but can not pick up a sheet of media from
|
||
|
that tray. cMarkingAgentFailure indicates there is a
|
||
|
failure with a marking agent and it may need to be
|
||
|
replaced. If the device supports more than one marking
|
||
|
agent, then the NOT-READY-MARKING-AGENT-FAILURE object
|
||
|
indicates all the marking agents that have failed. The
|
||
|
POS will indicate the marking agent failure recovery
|
||
|
process, if any."
|
||
|
::= { status-prt-eng 1 }
|
||
|
|
||
|
|
||
|
not-ready-laser-print-engine OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if the laser print engine sub-system in the
|
||
|
device is not ready. If there are no items in the
|
||
|
collection (i.e. no bits are set), then the laser print
|
||
|
engine sub-system is ready. If there is an item
|
||
|
present, then the item indicates what is causing the
|
||
|
laser print engine sub-system to be not ready."
|
||
|
::= { status-prt-eng 3 }
|
||
|
|
||
|
print-density OBJECT-TYPE
|
||
|
SYNTAX INTEGER(1..5)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the print density setting. Print
|
||
|
density is the instantaneous amount of marking agent
|
||
|
applied to the paper while printing. A value of zero
|
||
|
has the lowest print density, yielding a lighter page.
|
||
|
A value of 10 has the highest print density, yielding a
|
||
|
darker page. Each POS should document what values in
|
||
|
the 0 to 10 range are supported.
|
||
|
Additional information:
|
||
|
When this value is written, the page pipeline
|
||
|
will be flushed (all pages being printed are completed, no
|
||
|
new ones are started), the new density setting is set and
|
||
|
printing resumes. The acutal change in print density may be
|
||
|
gradual over several pages.
|
||
|
The supported values are 1 through 5. Setting to an
|
||
|
unsupported value causes the printer to substitue in a
|
||
|
a snap value and to return <noError>
|
||
|
status. The snap values are as follows:
|
||
|
<1 snaps to 1
|
||
|
>5 snaps to 5."
|
||
|
::= { settings-prt-eng 5 }
|
||
|
|
||
|
total-color-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..4294967296)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Total number of color pages printed by the device.
|
||
|
Additional information:
|
||
|
Any page with one or more color pixels is counted as
|
||
|
a color page. Pages that only contain black marks are not
|
||
|
counted by this object.
|
||
|
The counter will roll over to zero after 4,294,967,296 pages.
|
||
|
Each side of a duplexed sheet of media will be counted
|
||
|
independently based on the criteria listed above."
|
||
|
::= { status-prt-eng 7 }
|
||
|
|
||
|
default-manual-feed OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOff(1),
|
||
|
eOn(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the default manual feed value used by
|
||
|
the PDLs."
|
||
|
::= { settings-intray 4 }
|
||
|
|
||
|
mp-tray OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eCassette(2),
|
||
|
eFirst(3)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the value of the multi-purpose (MP)
|
||
|
tray configuration variable. The MP tray can be
|
||
|
configured to operate as an additional input tray
|
||
|
(eCassette), a manual feed slot (eManual), or in a
|
||
|
manner compatible with the LaserJet III manual feed slot
|
||
|
(eFirst). If configured for eFirst, if media is present
|
||
|
in the MP tray, that media is used (assuming the size
|
||
|
matches and the print job didn't specify another tray)
|
||
|
until the MP tray is empty.
|
||
|
Additional information:
|
||
|
The MP tray can be configured for use either as a paper
|
||
|
cassette or as a priority manual feed tray. When the tray is configured as a manual feed tray, unsolicited status messages are not generated when there is no
|
||
|
paper in the tray. LaserJet 4050 Series will pull media from TRAY 1 only if there is
|
||
|
a sheet present and it matches the needed size and type."
|
||
|
::= { settings-intray 5 }
|
||
|
|
||
|
tray-lock OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the list of locked input trays. The
|
||
|
printer only pulls media from a locked input tray when
|
||
|
the input tray is specifically requested by the print
|
||
|
job.
|
||
|
Additional information:
|
||
|
The HP LaserJet 2100 Series will pull paper from a
|
||
|
locked tray if that tray is specifically requested or if
|
||
|
the user presses the Go button on a paper mount override
|
||
|
and there is no paper available in an unlocked tray.
|
||
|
|
||
|
There must always be at least one unlocked tray. When
|
||
|
no optional lower cassette is installed and one tray is
|
||
|
locked, an attempt to lock the other tray will result in
|
||
|
the first tray unlocking. When the optional cassette is
|
||
|
installed and two trays are locked, an attempt to lock
|
||
|
the third will fail with a return status of
|
||
|
<badValue> and a return value
|
||
|
containing the collection of previously locked trays."
|
||
|
::= { settings-intray 6 }
|
||
|
|
||
|
not-ready-tray-missing OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates which trays are not currently installed that
|
||
|
is caused the device to be not ready."
|
||
|
::= { status-intray 1 }
|
||
|
|
||
|
|
||
|
not-ready-tray-empty OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates which trays contain no media causing the
|
||
|
device to be not ready. Some devices may treat tray
|
||
|
missing as a tray empty condition."
|
||
|
::= { status-intray 2 }
|
||
|
|
||
|
|
||
|
status-tray-missing OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates which trays are not currently installed that
|
||
|
is caused the device to be in a warning condition."
|
||
|
::= { status-intray 3 }
|
||
|
|
||
|
|
||
|
status-tray-empty OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates which trays contain no media causing the
|
||
|
device to be in a warning condition. Some devices may
|
||
|
treat tray missing as a tray empty condition."
|
||
|
::= { status-intray 4 }
|
||
|
|
||
|
low-marking-agent-processing OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eStop(1),
|
||
|
eCont(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes how the device processes a low
|
||
|
marking agent event. If eCont, then the device
|
||
|
continues to print. If eStop, then the device stops
|
||
|
until a continue event occurs."
|
||
|
::= { settings-marking-agent 3 }
|
||
|
|
||
|
|
||
|
default-ret OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOff(1),
|
||
|
eLight(2),
|
||
|
eMedium(3),
|
||
|
eDark(4)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the Resolution Enhancement Technology
|
||
|
setting. Devices that only support eOff and on should
|
||
|
map all other values to on and always return the same
|
||
|
non-eOff value to indicate on. The list of supported
|
||
|
values should be documented in the device POS.
|
||
|
Additional information:
|
||
|
Setting this object may cause a status of <noError> to be
|
||
|
returned, but the new value will not take effect until a job
|
||
|
boundary is reached. If a get is done on object before the job
|
||
|
boundary is reached, the value last set will be returned.
|
||
|
The value of this object is saved over a powercycle."
|
||
|
::= { imaging 5 }
|
||
|
|
||
|
|
||
|
default-print-quality OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..100)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the default print quality. A value of
|
||
|
zero has the lowest print quality. A value of 100 has
|
||
|
the highest print quality. Each POS should document
|
||
|
what values in the 0 to 100 range are supported.
|
||
|
Additional information:
|
||
|
In LaserJet 4050 Series, the supported values are 0 and
|
||
|
100. A value of zero has the lowest print
|
||
|
quality(ECONOMODE=ON), thus minimizes the amount of
|
||
|
toner used to print a page. A value of 100 has the
|
||
|
highest print quality (ECONOMODE=OFF), thus uses more
|
||
|
toner to print a page. Setting to an unsupported value
|
||
|
outside of the 0 to 100 range causes the printer to
|
||
|
return <badValue> status.
|
||
|
Setting to an unsupported value inside of the 0 to
|
||
|
100 range causes the printer to substitute in a snap
|
||
|
value (listed below) and to return
|
||
|
<noError> status.
|
||
|
The snap values are as follow:
|
||
|
0 to 50 snap to 0
|
||
|
51 to 100 snap to 100"
|
||
|
::= { imaging 7 }
|
||
|
|
||
|
|
||
|
hrstorageindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER(1..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A unique value for each logical storage area
|
||
|
contained by the host.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information (mass storage) :
|
||
|
Constant. The index is assigned by the
|
||
|
person controlling the printer object definition.
|
||
|
The value of the hrFileSystemStorageIndex and the
|
||
|
index of the prtStorageRefIndex use the value of
|
||
|
this object's index. The value of the object
|
||
|
matches the value of the object's index. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a get on this OID with no mass storage device
|
||
|
installed. This first volume installed will be number 2,
|
||
|
followed by the second. IDE will always be 2. If ram disk
|
||
|
and flash disk are installed then Flash disk will be 2 followed
|
||
|
by ram disk. The Storage types are:
|
||
|
IDE (EIO DISK), Flash Disk, Ram Disk"
|
||
|
::= { hrStorageEntry 1 }
|
||
|
|
||
|
|
||
|
hrstoragetype OBJECT-TYPE
|
||
|
SYNTAX OBJECT IDENTIFIER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The type of storage represented by this entry.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information (mass storage):
|
||
|
Constant. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device
|
||
|
installed.
|
||
|
HRMhrStorageFixedDisk is 1.3.6.1.2.1.25.2.1.4"
|
||
|
::= { hrStorageEntry 2 }
|
||
|
|
||
|
|
||
|
hrstoragedescr OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A description of the type and instance of the
|
||
|
storage described by this entry.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information (printer) :
|
||
|
This object is not localized.
|
||
|
Additional information (mass storage) :
|
||
|
This string indicates the location of the installed
|
||
|
mass storage device. The supported values are:
|
||
|
'Flash disk in DIMM slot 1'
|
||
|
'Flash disk in DIMM slot 2'
|
||
|
'Flash disk in DIMM slot 3'
|
||
|
'Disk in EIO 1'
|
||
|
'Disk in EIO 2'
|
||
|
'Disk in EIO 3'
|
||
|
'Static RAM disk using system memory'
|
||
|
Applications determine the location of the installed mass storage
|
||
|
device by getting this object. This string is not
|
||
|
localized. Returns <noSuchName>
|
||
|
status if attempting to perform a Get on this OID
|
||
|
with no mass storage device installed."
|
||
|
::= { hrStorageEntry 3 }
|
||
|
|
||
|
|
||
|
hrstorageallocationunits OBJECT-TYPE
|
||
|
SYNTAX INTEGER(1..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The size, in bytes, of the data objects allocated
|
||
|
from this pool. If this entry is monitoring
|
||
|
sectors, blocks, buffers, or packets, for example,
|
||
|
this number will commonly be greater than one.
|
||
|
Otherwise this number will typically be one.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information (printer) :
|
||
|
Unit is one byte.
|
||
|
Additional information (mass storage) :
|
||
|
Returns the value 1024 if the file system is
|
||
|
not initialized. Returns <noSuchName>
|
||
|
status if attempting to perform a Get on this OID
|
||
|
with no mass storage device installed."
|
||
|
::= { hrStorageEntry 4 }
|
||
|
|
||
|
|
||
|
hrstorageused OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The amount of the storage represented by this
|
||
|
entry that is allocated, in units of
|
||
|
hrStorageAllocationUnits.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
This object returns the amount of memory in use
|
||
|
by the printer at the current time. This object should not be
|
||
|
used when creating a print
|
||
|
job for the device because the amount of memory in use will
|
||
|
likely be different when the printer processes the print job.
|
||
|
Additional information (mass storage) :
|
||
|
Applications can determine the amount of used
|
||
|
space on the installed mass storage device by getting the
|
||
|
hrStorageAllocationUnits object and this object. The amount
|
||
|
of used space is these two returned values multiplied
|
||
|
together. Returns the value 0 if the file system
|
||
|
is not initialized. Returns <noSuchName>
|
||
|
status if attempting to perform a Get on this OID
|
||
|
with no mass storage device installed."
|
||
|
::= { hrStorageEntry 6 }
|
||
|
|
||
|
|
||
|
hrstorageallocationfailures OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The number of requests for storage represented by
|
||
|
this entry that could not be honored due to not
|
||
|
enough storage. It should be noted that as this
|
||
|
object has a SYNTAX of Counter, that it does not
|
||
|
have a defined initial value. However, it is
|
||
|
recommended that this object be initialized to
|
||
|
zero.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information (printer):
|
||
|
This object is set to zero at power on and when any
|
||
|
reset is done via prtGeneralReset.
|
||
|
This object is incremented whenever the printer is
|
||
|
short on memory (codewise: when PersMemoryCycle is
|
||
|
called with a parameter of 2).
|
||
|
Additional information (mass storage):
|
||
|
Total number of writes that failed
|
||
|
since power on) due to the mass storage device
|
||
|
being full. Returns the value 0 when the file
|
||
|
system has not been initialized. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device
|
||
|
installed."
|
||
|
::= { hrStorageEntry 7 }
|
||
|
|
||
|
|
||
|
hrdeviceindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER(1..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A unique value for each device contained by the
|
||
|
host. The value for each device must remain
|
||
|
constant at least from one re-initialization of the
|
||
|
agent to the next re-initialization.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information (printer):
|
||
|
The entry in the Device Table which
|
||
|
describes the printer.
|
||
|
Additional information (mass storage):
|
||
|
Constant. The index is assigned by the
|
||
|
person controlling the printer object definition.
|
||
|
All device/mass storage/file system/partition
|
||
|
tables in Host Resources MIB and the Printer MIB that
|
||
|
relate to the mass storage device use the same index value.
|
||
|
The value of the index of the following objects is
|
||
|
this object's value:
|
||
|
prtDeviceRefIndex
|
||
|
hrDiskStorageIndex
|
||
|
hrPartitionIndex
|
||
|
hrFSIndex
|
||
|
The value of the object matches the value of the
|
||
|
object's index. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device
|
||
|
installed."
|
||
|
|
||
|
::= { hrDeviceEntry 1 }
|
||
|
|
||
|
|
||
|
hrdevicetype OBJECT-TYPE
|
||
|
SYNTAX OBJECT IDENTIFIER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An indication of the type of device.
|
||
|
If this value is `hrDeviceProcessor { hrDeviceTypes
|
||
|
3 }' then an entry exists in the hrProcessorTable
|
||
|
which corresponds to this device.
|
||
|
If this value is `hrDeviceNetwork { hrDeviceTypes 4
|
||
|
}', then an entry exists in the hrNetworkTable
|
||
|
which corresponds to this device.
|
||
|
If this value is `hrDevicePrinter { hrDeviceTypes 5
|
||
|
}', then an entry exists in the hrPrinterTable
|
||
|
which corresponds to this device.
|
||
|
If this value is `hrDeviceDiskStorage {
|
||
|
hrDeviceTypes 6 }', then an entry exists in the
|
||
|
hrDiskStorageTable which corresponds to this
|
||
|
device.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information (mass storage):
|
||
|
Constant. Applications should determine if
|
||
|
a mass storage device is installed by getting this object.
|
||
|
If the response is something other than HRMhrDeviceDiskStorage,
|
||
|
the application knows this row in the hrDeviceTable does not
|
||
|
refer to a mass storage object. Due to restrictions placed on
|
||
|
this object by the Host Resources Disk Table, the value of this
|
||
|
object must be HRMhrDeviceDiskStorge. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device
|
||
|
installed. HRMhrDeviceDiskStorage is 1.3.6.1.2.1.25.3.1.6"
|
||
|
::= { hrDeviceEntry 2 }
|
||
|
|
||
|
|
||
|
hrdevicestatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eHrunning(2),
|
||
|
eHwarning(3),
|
||
|
eHdown(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current operational state of the device
|
||
|
described by this row of the table. A value
|
||
|
unknown(1) indicates that the current state of the
|
||
|
device is unknown. running(2) indicates that the
|
||
|
device is up and running and that no unusual error
|
||
|
conditions are known. The warning(3) state
|
||
|
indicates that agent has been informed of an
|
||
|
unusual error condition by the operational software
|
||
|
(e.g., a disk device driver) but that the device is
|
||
|
still 'operational'. An example would be high
|
||
|
number of soft errors on a disk. A value of
|
||
|
testing(4), indicates that the device is not
|
||
|
available for use because it is in the testing
|
||
|
state. The state of down(5) is used only when the
|
||
|
agent has been informed that the device is not
|
||
|
available for any use.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information (printer) :
|
||
|
The printer's condition is mapped as follows (printer):
|
||
|
|
||
|
eHrunning -- Printer ready to print or is printing. May be in power save
|
||
|
mode.
|
||
|
|
||
|
eHwarning -- A condition exists that needs attention but it is
|
||
|
not currently preventing printing. A non-critical alert is active.
|
||
|
|
||
|
eHdown -- Printer is not printing because it is offline or a critical
|
||
|
alert is active. Human interaction is needed to bring the printer to
|
||
|
a ready state.
|
||
|
Additional information (mass storage) :
|
||
|
Returns mass storage device status information.
|
||
|
running -- mass storage device functional. May be in power save
|
||
|
mode.
|
||
|
warning -- The mass storage device failed a self-test but completed
|
||
|
the power-on initialization sequence. The mass storage device
|
||
|
is readable even when the mass storage device fails the power-up
|
||
|
self-test in order to give the customer a chance to
|
||
|
retrieve any data that can be made available.
|
||
|
testing -- Mass storage device is executing a test.
|
||
|
down -- Mass storage device is non-functional. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device
|
||
|
installed."
|
||
|
::= { hrDeviceEntry 5 }
|
||
|
|
||
|
|
||
|
hrprinterstatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eHother(1),
|
||
|
eHidle(3),
|
||
|
eHprinting(4),
|
||
|
eHwarmup(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current status of this printer device. When
|
||
|
in the idle(1), printing(2), or warmup(3) state,
|
||
|
the corresponding hrDeviceStatus should be
|
||
|
running(2) or warning(3). When in the unknown
|
||
|
state, the corresponding hrDeviceStatus should be
|
||
|
unknown(1).
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
The printer's condition is mapped as follows:
|
||
|
|
||
|
eHother -- The printer is offline or a critical alert is active.
|
||
|
|
||
|
eHidle -- The printer is not doing any of the items listed below
|
||
|
for eHprinting status.
|
||
|
|
||
|
eHprinting -- A job is currently being processed or printed or a PJL job
|
||
|
is being processed.
|
||
|
|
||
|
eHwarmup -- If hrDeviceStatus is eHdown, then the printer is currently
|
||
|
offline but is resolving the condition that caused it be offline.
|
||
|
If hrDeviceStatus is eHrunning, then the printer was in power save mode
|
||
|
and is now ready ready to print."
|
||
|
::= { hrPrinterEntry 1 }
|
||
|
|
||
|
|
||
|
hrprinterdetectederrorstate OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object represents any error conditions
|
||
|
detected by the printer. The error conditions are
|
||
|
encoded as bits in an octet string, with the
|
||
|
following definitions:
|
||
|
Condition Bit # hrDeviceStatus
|
||
|
lowPaper 0 warning(3)
|
||
|
noPaper 1 down(5)
|
||
|
lowToner 2 warning(3)
|
||
|
noToner 3 down(5)
|
||
|
doorOpen 4 down(5)
|
||
|
jammed 5 down(5)
|
||
|
offline 6 down(5)
|
||
|
serviceRequested 7 warning(3)
|
||
|
If multiple conditions are currently detected and
|
||
|
the hrDeviceStatus would not otherwise be
|
||
|
unknown(1) or testing(4), the hrDeviceStatus shall
|
||
|
correspond to the worst state of those indicated,
|
||
|
where down(5) is worse than warning(3) which is
|
||
|
worse than running(2).
|
||
|
Bits are numbered starting with the most
|
||
|
significant bit of the first byte being bit 0, the
|
||
|
least significant bit of the first byte being bit
|
||
|
7, the most significant bit of the second byte
|
||
|
being bit 8, and so on. A one bit encodes that
|
||
|
the condition was detected, while a zero bit
|
||
|
encodes that the condition was not detected.
|
||
|
This object is useful for alerting an operator to
|
||
|
specific warning or error conditions that may
|
||
|
occur, especially those requiring human
|
||
|
intervention.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4050 Series reports error conditions as follows:
|
||
|
|
||
|
lowPaper -- A tray is empty, but the media to be loaded is not
|
||
|
currently needed.
|
||
|
hrDeviceStatus = eHwarning;
|
||
|
hrPrinterStatus = eHidle or eHprinting;
|
||
|
A non-critical alert is active.
|
||
|
|
||
|
noPaper -- A tray is empty and must be filled for printing to continue.
|
||
|
hrDeviceStatus = eHdown;
|
||
|
hrPrinterStatus = eHother;
|
||
|
A critical alert is active.
|
||
|
|
||
|
lowToner -- Toner is almost gone. The quality of printed pages will begin
|
||
|
to deteriorate until the toner is completely gone.
|
||
|
hrDeviceStatus = eHwarning;
|
||
|
hrPrinterStatus = eHidle or eHprinting;
|
||
|
A non-critical alert is active.
|
||
|
|
||
|
noToner -- LaserJet 4050 Series printers do not report this condition.
|
||
|
|
||
|
coverOpen -- A printer cover or door is open.
|
||
|
hrDeviceStatus = eHdown;
|
||
|
hrPrinterStatus = eHother;
|
||
|
A critical alert is active.
|
||
|
|
||
|
jammed -- Paper is jammed and the printer will be unable to continue
|
||
|
printing until the jam is cleared.
|
||
|
hrDeviceStatus = eHdown;
|
||
|
hrPrinterStatus = eHother;
|
||
|
A critical alert is active.
|
||
|
|
||
|
offline -- Printer is offline and will not accept new print jobs until
|
||
|
it is online again.
|
||
|
hrDeviceStatus = eHdown;
|
||
|
hrPrinterStatus = eHother;
|
||
|
A critical alert is active.
|
||
|
|
||
|
serviceRequested -- Any status or error condition not listed
|
||
|
above. If the condition prevents printing, the 'offline'
|
||
|
bit is also set and the hrDeviceStatus and hrPrinterStatus listed for
|
||
|
offline above are returned.
|
||
|
hrDeviceStatus = eHwarning;
|
||
|
hrPrinterStatus = eHidle or eHprinting;
|
||
|
A non-critical alert is active."
|
||
|
::= { hrPrinterEntry 2 }
|
||
|
|
||
|
|
||
|
prtgeneralconfigchanges OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..2147483648)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Counts configuration changes that change the capabilities of
|
||
|
a printer, such as the addition/deletion of input/output bins,
|
||
|
the addition/deletion of interpreters, or changes in media
|
||
|
size. Such changes will often affect the capability of the
|
||
|
printer to service certain types of print jobs.
|
||
|
Management applications may cache infrequently changed
|
||
|
configuration information about sub-units on the printer.
|
||
|
This object should be incremented whenever the agent wishes
|
||
|
such applications to invalidate that cache and re-download
|
||
|
all of this configuration information, thereby signaling a
|
||
|
change in the printer's configuration.
|
||
|
|
||
|
For example, if an input tray that contained paper of
|
||
|
different dimensions was added, this counter would be
|
||
|
incremented.
|
||
|
As an additional example, this counter would not be
|
||
|
incremented when an input tray is removed or the level of an
|
||
|
input device changes.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
This is a 32 bit counter (unsigned). When it reaches
|
||
|
its maximum value, it will roll to zero."
|
||
|
::= { prtGeneralEntry 1 }
|
||
|
|
||
|
|
||
|
prtgeneralcurrentlocalization OBJECT-TYPE
|
||
|
SYNTAX INTEGER(1..17)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of the prtLocalizationIndex corresponding to the
|
||
|
current language, country, and character set to be used for
|
||
|
localized string values that are identified as being dependent
|
||
|
on the value of this object. Note that this object does not
|
||
|
apply to localized strings in the prtConsole group or to any
|
||
|
object that is not explicitly identified as being localized
|
||
|
according to prtGeneralCurrentLocalization.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The value of this object is saved in NVRAM."
|
||
|
::= { prtGeneralEntry 2 }
|
||
|
|
||
|
|
||
|
prtgeneralreset OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePnotResetting(3),
|
||
|
ePpowerCycleReset(4),
|
||
|
ePresetToNVRAM(5),
|
||
|
ePresetToFactoryDefaults(6)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Setting this value to `powerCycleReset', `resetToNVRAM', or
|
||
|
`resetToFactoryDefaults' will result in the resetting of the
|
||
|
printer. When read, this object will always have the value
|
||
|
`notResetting(3)', and a SET of the value `notResetting' shall
|
||
|
have no effect on the printer. Some of the defined values are
|
||
|
optional. However, every implementation must support at least
|
||
|
the values `notResetting' and 'resetToNVRAM'.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML USER-NVRAM-RESET and POWER-ON-RESET.
|
||
|
|
||
|
The, the following sequence of events occur when this object is set to
|
||
|
ePpowerCycleReset, ePresetToNVRAM, or ePresetToFactoryDefaults:
|
||
|
1. Wait until a job boundary.
|
||
|
2. The paper path is flushed.
|
||
|
3. The printer is reset per the request. The printer will respond to PML
|
||
|
requests up to this point in time.
|
||
|
|
||
|
All settings will make the printer go thru its power-on initialization
|
||
|
routines and I/O cards are reset.
|
||
|
|
||
|
When this object is set to ePpowerCycleReset or ePresetToNVRAM, the printer
|
||
|
performs its power on initialization routines. I/O cards are reset, although
|
||
|
NVRAM on the cards is not changed, and all I/O buffers are flushed. This is
|
||
|
equivalent to turning the printer off and then on again.
|
||
|
|
||
|
Setting this object to ePresetToFactoryDefaults causes the same action as
|
||
|
ePpowerCycleReset exept that it also changes all configurable settings back
|
||
|
to their factory defaults. It is equivalent to doing a Cold Reset from the
|
||
|
control panel while turning on the printer."
|
||
|
::= { prtGeneralEntry 3 }
|
||
|
|
||
|
|
||
|
prtgeneralcurrentoperator OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..32))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The name of the person who is responsible for operating
|
||
|
this printer. It is suggested that this string include
|
||
|
information that would enable other humans to reach the operator,
|
||
|
such as a phone number. As a convention to facilitate automatic
|
||
|
notification of the operator by the agent or the network
|
||
|
management station, the phone number, fax number or email address
|
||
|
should be placed on a separate line starting with ASCII LF (hex
|
||
|
0x0A) and the ASCII text string (without the quotes): 'phone: ',
|
||
|
'fax: ', and 'email: ', respectively. Phone numbers may contain
|
||
|
digits, whitespace and parentheses, which shall be ignored. Phone
|
||
|
numbers may also include ASCII comma characters(hex 2C) that are
|
||
|
used to indicate a two-second pause during the dialing sequence.
|
||
|
If either the phone, fax, or email information is not available,
|
||
|
then a line should not be included for this information.
|
||
|
NOTE: For interoperability purposes, it is advisable to use email
|
||
|
addresses formatted according to RFC 822 requirements.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML SYSTEM-CONTACT.
|
||
|
The maximum supported string length is 32 characters.
|
||
|
Length of 32 was chosen so a phone number could be
|
||
|
included with the name.
|
||
|
If the user entered string is too long, the device
|
||
|
will store as much as possible and will return the
|
||
|
<noError> status."
|
||
|
::= { prtGeneralEntry 4 }
|
||
|
|
||
|
|
||
|
prtgeneralserviceperson OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..32))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The name of the person responsible for servicing this
|
||
|
printer. It is suggested that this string include information
|
||
|
that would enable other humans to reach the service person, such
|
||
|
as a phone number. As a convention to facilitate automatic
|
||
|
notification of the service person by the agent or a network
|
||
|
management station, the phone number, fax number or email address
|
||
|
should be placed on a separate line starting with ASCII LF (hex
|
||
|
0x0A) and the ASCII text string (without the quotes): 'phone: ',
|
||
|
'fax: ', and 'email: ', respectively. Phone numbers may contain
|
||
|
digits, whitespace and parentheses, which shall be ignored. Phone
|
||
|
numbers can also include one or more ASCII comma characters(hex
|
||
|
2C) to indicate a two-second pause during the dialing sequence.
|
||
|
If either the phone,fax, or email information is not available,
|
||
|
then a line should not included for this information.
|
||
|
NOTE: For interoperability purposes, it is advisable to use email
|
||
|
addresses formatted according to RFC 822 requirements.
|
||
|
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML SYSTEM-CONTACT.
|
||
|
The maximum supported string length is 32 characters.
|
||
|
Length of 32 was chosen so a phone number could be
|
||
|
included with the name.
|
||
|
If the user entered string is too long, the device
|
||
|
will store as much as possible and will return the
|
||
|
<noError> status."
|
||
|
::= { prtGeneralEntry 5 }
|
||
|
|
||
|
|
||
|
prtconsolelocalization OBJECT-TYPE
|
||
|
SYNTAX INTEGER(1..17)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of the prtLocalizationIndex corresponding to
|
||
|
the language, country, and character set to be used for the
|
||
|
console. This localization applies both to the actual display
|
||
|
on the console as well as the encoding of these console
|
||
|
objects in management operations.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The value of this object is saved in NVRAM.
|
||
|
If a localized string is currently being displayed on the control panel by the
|
||
|
device, changing this object will cause the displayed string to be changed
|
||
|
to its new value. If this object is changed while the printer is processing
|
||
|
a page that contains localized strings, the results are undefined."
|
||
|
::= { prtGeneralEntry 10 }
|
||
|
|
||
|
|
||
|
prtconsolenumberofdisplaylines OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of lines on the printer's physical
|
||
|
display. This value is 0 if there are no lines on the
|
||
|
physical display or if there is no physical display
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The printer has two physical lines on the display,
|
||
|
however, in many cases up to four seperate lines
|
||
|
of text may be displayed by alternating pairs of
|
||
|
lines every three seconds. Thus the display really
|
||
|
has four logical lines for displaying messages.
|
||
|
This object will return the number of logical
|
||
|
display lines supported by the printer."
|
||
|
::= { prtGeneralEntry 11 }
|
||
|
|
||
|
|
||
|
prtconsolenumberofdisplaychars OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of characters per line displayed on the physical
|
||
|
display. This value is 0 if there are no lines on the
|
||
|
physical display or if there is no physical display
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtGeneralEntry 12 }
|
||
|
|
||
|
|
||
|
prtconsoledisable OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePoperatorConsoleEnabled(3),
|
||
|
ePoperatorConsoleDisabled(4),
|
||
|
ePoperatorConsoleEnabledLevel1(5),
|
||
|
ePoperatorConsoleEnabledLevel2(6)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"If the object prtConsoleDisable has value
|
||
|
'operatorConsoleDisabled' then input is not accepted from the
|
||
|
operator console. If the object prtConsoleDisable has the value
|
||
|
'operatorConsoleEnabled' then input is accepted from the
|
||
|
operator console. If the object prtConsoleDisable has the value
|
||
|
'operatorConsoleEnabledLevel1','operatorConsoleEnabledLevel2' or
|
||
|
'operatorConsoleEnabledLevel3' then limited input is accepted
|
||
|
from the operator console; the limitations are product specific,
|
||
|
however, the limitations are generally less restrictive for
|
||
|
operatorConsoleEnabledLevel1 than for
|
||
|
operatorConsoleEnabledLeve2, which is less restrictive than
|
||
|
operatorConsoleEnabledLevel3.
|
||
|
The value of the prtConsoleDisable object is a type-2
|
||
|
enumeration.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
If the object prtConsoleDisable has value
|
||
|
'ePoperatorConsoleDisabled' then manual input is not
|
||
|
accepted from the operator console. If the object prtConsoleDisable has the
|
||
|
value 'ePoperatorConsoleEnabled' then manual input is accepted from the
|
||
|
operator console.
|
||
|
The following menus are locked with these corresponding
|
||
|
values:
|
||
|
ePoperatorConsoleEnabled (no locking)
|
||
|
ePoperatorConsoleEnabledLevel1 (minimal locking)
|
||
|
RESETS MENU
|
||
|
CONFIGURATION MENU
|
||
|
I/O MENU
|
||
|
ePoperatorConsoleEnabledLevel2 (moderate locking)
|
||
|
PRINT QUALITY MENU
|
||
|
PAPER HANDLING MENU
|
||
|
menus in level 1
|
||
|
ePoperatorConsoleDisabled (maximum locking)
|
||
|
PRINTING MENU
|
||
|
INFORMATION MENU
|
||
|
Job Cancel
|
||
|
menus in levels 1 and 2"
|
||
|
::= { prtGeneralEntry 13 }
|
||
|
|
||
|
|
||
|
prtgeneralstartuppage OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePnotPresent(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Used to enable or disable printing a startup page. If
|
||
|
enabled, a startup page will be printed shortly after
|
||
|
power-up, when the device is ready. Typical startup
|
||
|
pages include test patterns and/or printer configuration
|
||
|
information.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtGeneralEntry 14 }
|
||
|
|
||
|
|
||
|
prtgeneralbannerpage OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePnotPresent(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Used to enable or disable printing banner pages at the
|
||
|
beginning of jobs. This is a master switch which applies
|
||
|
to all jobs, regardless of interpreter.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtGeneralEntry 15 }
|
||
|
|
||
|
|
||
|
prtgeneralprintername OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..32))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"An administrator-specified name for this printer.
|
||
|
Depending upon implementation of this printer, the value of this
|
||
|
object may or may not be same as the value for the MIB-II
|
||
|
'SysName' object.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The maximum supported string length is 32 characters.
|
||
|
Length of 32 was chosen so a phone number could be
|
||
|
included with the name.
|
||
|
If the user-entered string is too long, the device
|
||
|
will store as much as possible and will return the
|
||
|
<noError> status.
|
||
|
The value of this object is saved over a power cycle."
|
||
|
::= { prtGeneralEntry 16 }
|
||
|
|
||
|
|
||
|
prtgeneralserialnumber OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..10))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A recorded serial number for this device that indexes some type
|
||
|
device catalog or inventory. This value is usually set by the
|
||
|
device manufacturer but the MIB supports the option of
|
||
|
writeability for this object for site-specific administration of
|
||
|
device inventory or tracking.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtGeneralEntry 17 }
|
||
|
|
||
|
|
||
|
prtalertcriticalevents OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A running counter of the number of critical alert events
|
||
|
that have been recorded in the alert table. The value of this
|
||
|
object is RESET in the event of a power cycle operation (i.e.,
|
||
|
the value is not persistent.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
This object is set to zero every time the printer is
|
||
|
turned on."
|
||
|
::= { prtGeneralEntry 18 }
|
||
|
|
||
|
|
||
|
prtalertallevents OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A running counter of the total number of alert event entries
|
||
|
(critical and non-critical) that have been recorded in the
|
||
|
alert table
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
This object is set to zero every time the printer is
|
||
|
turned on. (It is not persistent through a power-cycle.)"
|
||
|
::= { prtGeneralEntry 19 }
|
||
|
|
||
|
|
||
|
prtlocalizationlanguage OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..2))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A two character language code from ISO 639. Examples
|
||
|
en, gb, ca, fr, de.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The languages supported by LaserJet 4050 Series are English, French,
|
||
|
German, Italian, Spanish, Swedish, Danish, Norwegian, Dutch, Finnish,
|
||
|
Portuguese, Turkish, Polish, Japanese, Russian, Czech, and Hungarian."
|
||
|
::= { prtLocalizationEntry 2 }
|
||
|
|
||
|
|
||
|
prtlocalizationcountry OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..2))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A two character country code from ISO 3166, a blank string
|
||
|
(two space characters) shall indicate that the country is
|
||
|
not defined. Examples: US, FR, DE, ...
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The languages supported by LaserJet 4050 Series (and corresponding
|
||
|
country) are English (US, United States), French (FR, France),
|
||
|
German (DE, Germany), Italian (IT, Italy), Spanish (ES, Spain),
|
||
|
Swedish (SE, Sweden), Danish (DK, Denmark), Norwegian (NO, Norway),
|
||
|
Dutch (NL, Netherlands), Finnish (FI, Finland), Portuguese (PT, Portugal),
|
||
|
Turkish (TR, Turkey), Polish (PL, Poland), Japanese (JP, Japan),
|
||
|
Russian, (RU, Russia), Czech (CS, Czechoslovakia),
|
||
|
Hungarian (HU, Hungary)"
|
||
|
::= { prtLocalizationEntry 3 }
|
||
|
|
||
|
|
||
|
prtlocalizationcharacterset OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePcsHPRoman8(2004),
|
||
|
ePcsISOLatin2(5),
|
||
|
ePcsISOLatin5(12),
|
||
|
ePcsWindows31J(2024),
|
||
|
ePcsISOLatinCyrillic(8)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The coded character set used for this localization.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtLocalizationEntry 4 }
|
||
|
|
||
|
|
||
|
prtstoragerefindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER(1..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of the hrDeviceIndex of the printer device that this
|
||
|
storageEntry is associated with.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information (mass storage):
|
||
|
Constant. The index value indicates
|
||
|
the hrStorageTable index for this storage device.
|
||
|
The value indicates the hrDeviceTable index for the
|
||
|
printer which uses this storage device. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no storage device
|
||
|
is installed."
|
||
|
::= { prtStorageRefEntry 2 }
|
||
|
|
||
|
|
||
|
prtdevicerefindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER(1..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of the hrDeviceIndex of the printer device that this
|
||
|
deviceEntry is associated with.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information (mass storage) :
|
||
|
Constant. The index indicates the
|
||
|
hrDeviceIndex for this mass storage device. The value indicates
|
||
|
the hrDeviceIndex for the printer which uses this
|
||
|
mass storage device. Returns <noSuchName> status
|
||
|
if attempting to perform a Get on this OID with no
|
||
|
mass storage device installed."
|
||
|
|
||
|
::= { prtDeviceRefEntry 2 }
|
||
|
|
||
|
|
||
|
prtmarkeraddressabilityfeeddir OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum number of addressable marking positions in the feed
|
||
|
direction per 10000 units of measure specified by
|
||
|
prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or
|
||
|
'infinite' while a value of (-2) implies 'unknown'.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
This object indicates the value of the resolution
|
||
|
(dots per inch) setting for the printer. LaserJet 5000 Series
|
||
|
and LaserJet 4000 Series support 300, 600 and 1200 dots per inch. LaserJet 8100 Series
|
||
|
and LaserJet 8000 Series supports 300 or 600 dots per inch. 600 dots per inch is
|
||
|
the default."
|
||
|
::= { prtMarkerEntry 9 }
|
||
|
|
||
|
|
||
|
prtmarkeraddressabilityxfeeddir OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum number of addressable marking positions in the cross
|
||
|
feed direction in 10000 units of measure specified by
|
||
|
prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or
|
||
|
'infinite' while a value of (-2) implies 'unknown'.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
This object indicates the value of the resolution
|
||
|
(dots per inch) setting for the printer. LaserJet 5000 Series
|
||
|
and LaserJet 4000 Series support 300, 600 and 1200 dots per inch. LaserJet 8100 Series
|
||
|
and LaserJet 8000 Series supports 300 or 600 dots per inch. 600 dots per inch is
|
||
|
the default."
|
||
|
::= { prtMarkerEntry 10 }
|
||
|
|
||
|
|
||
|
prtconsoledisplaybuffertext OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The content of a line in the logical display buffer of
|
||
|
the operator's console of the printer. When a write
|
||
|
operation occurs, normally a critical message, to one of
|
||
|
the LineText strings, the agent should make that line
|
||
|
displayable if a physical display is present. Writing
|
||
|
a zero length string clears the line. It is an
|
||
|
implementation-specific matter as to whether the agent allows
|
||
|
a line to be overwritten before it has been cleared.
|
||
|
Printer generated strings shall be in the localization
|
||
|
specified by prtConsoleLocalization. Management Application
|
||
|
generated strings should be localized by the Management
|
||
|
Application.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML STATUS-MSG-LINE1-PART1 and
|
||
|
STATUS-MSG-LINE2-PART1 (read functionality).
|
||
|
The proprietary objects BACKGROUND-STATUS-MSG-LINE1-PART1
|
||
|
and BACKGROUND-STATUS-MSG-LINE2-PART1 should be used to
|
||
|
write messages to the control panel display.
|
||
|
|
||
|
prtConsoleDisplayBufferText.1.[1..6] maps to logical lines
|
||
|
1-6 of the display.
|
||
|
|
||
|
Most of the time the display will show a single one or two line
|
||
|
message. This message can be retrieved by reading
|
||
|
prtConsoleDisplayBufferText.1.1 and
|
||
|
prtConsoleDisplayBufferText.1.2. In this case
|
||
|
prtConsoleDisplayBufferText.1.[3..6] will be NULL.
|
||
|
|
||
|
If prtConsoleDisplayBufferText.1.3 or
|
||
|
prtConsoleDisplayBufferText.1.4 is not NULL, the display will
|
||
|
be alternating.
|
||
|
|
||
|
If prtConsoleDisplayBufferText.1.[5..6] are NULL, the display
|
||
|
will alternate prtConsoleDisplayBufferText.1.[1..2] with
|
||
|
prtConsoleDisplayBufferText.1.[3..4].
|
||
|
|
||
|
If prtConsoleDisplayBufferText.1.5 or
|
||
|
prtConsoleDisplayBufferText.1.6 is not NULL, the display will
|
||
|
show prtConsoleDisplayBufferText.1.[1..2] then
|
||
|
prtConsoleDisplayBufferText.1.[3..4] then
|
||
|
prtConsoleDisplayBufferText.1.[5..6].
|
||
|
|
||
|
The display will alternate between line pairs at three second
|
||
|
intervals. "
|
||
|
::= { prtConsoleDisplayBufferEntry 2 }
|
||
|
|
||
|
|
||
|
prtconsoleontime OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object, in conjunction with prtConsoleOffTime, defines
|
||
|
the current status of the light. If both prtConsoleOnTime and
|
||
|
prtConsoleOffTime are non-zero, the lamp is blinking and the
|
||
|
values presented define the on time and off time, respectively,
|
||
|
in milliseconds. If prtConsoleOnTime is zero and
|
||
|
prtConsoleOffTime is non-zero, the lamp is off. If
|
||
|
prtConsoleOffTime is zero and prtConsoleOnTime is non-zero,
|
||
|
the lamp is on. If both values are zero the status of the
|
||
|
lamp is undefined.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
There are three control panel LED's: Ready (1),
|
||
|
Data (2), and Attention (3). When an LED blinks, it is typically on for
|
||
|
one half second and off for one half second. The value used for this object
|
||
|
is 500 when the LED is on or blinking, otherwise it is zero."
|
||
|
::= { prtConsoleLightEntry 2 }
|
||
|
|
||
|
|
||
|
prtconsoleofftime OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object, in conjunction with prtConsoleOnTime, defines
|
||
|
the current status of the light. If both prtConsoleOnTime and
|
||
|
prtConsoleOffTime are non-zero, the lamp is blinking and the
|
||
|
values presented define the on time and off time, respectively,
|
||
|
in milliseconds. If prtConsoleOnTime is zero and
|
||
|
prtConsoleOffTime is non-zero, the lamp is off. If
|
||
|
prtConsoleOffTime is zero and prtConsoleOnTime is non-zero,
|
||
|
the lamp is on. If both values are zero the status of the
|
||
|
lamp is undefined.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
There are three control panel LED's: Ready (1),
|
||
|
Data (2), and Attention (3). When an LED blinks, it is typically on for
|
||
|
one half second and off for one half second. The value used for this object
|
||
|
is 500 when the LED is off or blinking, otherwise it is zero."
|
||
|
::= { prtConsoleLightEntry 3 }
|
||
|
|
||
|
|
||
|
prtconsoledescription OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The vendor description or label of this light in the
|
||
|
localization specified by prtConsoleLocalization.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtConsoleLightEntry 5 }
|
||
|
|
||
|
|
||
|
prtalertseveritylevel OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePcriticalBinaryChangeEvent(3),
|
||
|
ePwarningUnaryChangeEvent(4),
|
||
|
ePwarningBinaryChangeEvent(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The level of severity of this alert table entry. The printer
|
||
|
determines the severity level assigned to each entry into the
|
||
|
table.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtAlertEntry 2 }
|
||
|
|
||
|
|
||
|
prtalerttraininglevel OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePuntrained(3),
|
||
|
ePtrained(4),
|
||
|
ePfieldService(5),
|
||
|
ePmanagement(6),
|
||
|
ePnoInterventionRequired(7)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"See textual convention PrtAlertTrainingLevelTC
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The value of this object depends on the alert.
|
||
|
Some examples:
|
||
|
ePfieldService: Marker failure.
|
||
|
ePtrained: Toner low.
|
||
|
ePuntrained: Paper low/out.
|
||
|
ePmanagement: Configuration change."
|
||
|
::= { prtAlertEntry 3 }
|
||
|
|
||
|
|
||
|
prtalertgroup OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePgeneralPrinter(5),
|
||
|
ePcover(6),
|
||
|
ePinput(8),
|
||
|
ePoutput(9),
|
||
|
ePmarker(10),
|
||
|
ePmarkerSupplies(11),
|
||
|
ePchannel(14)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The type of sub-unit within the printer model that this alert
|
||
|
is related. Input, output, and markers are examples of
|
||
|
printer model groups, i.e., examples of types of sub-units.
|
||
|
Wherever possible, these enumerations match the
|
||
|
sub-identifier that identifies the relevant table in the
|
||
|
printmib.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtAlertEntry 4 }
|
||
|
|
||
|
|
||
|
prtalertgroupindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"An index of the row within the principle table in the
|
||
|
group identified by prtAlertGroup that represents the
|
||
|
sub-unit of the printer that caused this alert. The
|
||
|
combination of the prtAlertGroup and the prtAlertGroupIndex defines
|
||
|
exactly which printer sub-unit caused the alert.; for
|
||
|
example, Input #3, Output #2, and Marker #1.
|
||
|
Every object in this MIB is indexed with hrDeviceIndex and
|
||
|
optionally, another index variable. If this other index
|
||
|
variable is present in the table that generated the alert, it
|
||
|
will be used as the value for this object. Otherwise, this
|
||
|
value shall be -1.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtAlertEntry 5 }
|
||
|
|
||
|
|
||
|
prtalertlocation OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The sub-unit location that is defined by the printer
|
||
|
manufacturer to further refine the location of this alert
|
||
|
within the designated sub-unit. The location is used in
|
||
|
conjunction with the Group and GroupIndex values; for
|
||
|
example, there is an alert in Input #2 at location number 7.
|
||
|
The value (-2) indicates unknown
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtAlertEntry 6 }
|
||
|
|
||
|
|
||
|
prtalertcode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePcoverOpened(3),
|
||
|
ePjam(8),
|
||
|
ePsubunitMissing(9),
|
||
|
ePsubunitAlmostEmpty(12),
|
||
|
ePsubunitEmpty(13),
|
||
|
ePsubunitAlmostFull(14),
|
||
|
ePsubunitFull(15),
|
||
|
ePsubunitOffline(22),
|
||
|
ePsubunitPowerSaver(23),
|
||
|
ePsubunitMotorFailure(33),
|
||
|
ePsubunitMemoryExhausted(34),
|
||
|
ePmarkerFuserUnderTemperature(1001),
|
||
|
ePmarkerFuserOverTemperature(1002),
|
||
|
ePmarkerTonerEmpty(1101),
|
||
|
ePmarkerTonerAlmostEmpty(1104)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"See associated textual convention PrtAlertCodeTC
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtAlertEntry 7 }
|
||
|
|
||
|
|
||
|
prtalertdescription OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A description of this alert entry in the localization
|
||
|
specified by prtGeneralCurrentLocalization. The description is
|
||
|
provided by the printer to further elaborate on the enumerated
|
||
|
alert or provide information in the case where the code is
|
||
|
classified as `other' or `unknown'. The printer is required
|
||
|
to return a description string but the string may be a null
|
||
|
string.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtAlertEntry 8 }
|
||
|
|
||
|
|
||
|
prtalerttime OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of sysUpTime at the time that this alert was
|
||
|
generated.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtAlertEntry 9 }
|
||
|
|
||
|
|
||
|
status-controller2 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if the hardware controller sub-system in a
|
||
|
warning condition."
|
||
|
::= { status-system 23 }
|
||
|
|
||
|
job-input-auto-continue-timeout OBJECT-TYPE
|
||
|
SYNTAX INTEGER(-1..3600)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of seconds the device waits after a job
|
||
|
related continuable error occurs before automatically
|
||
|
continuing. An example job related continuable error is
|
||
|
the job requesting a media size that is not available.
|
||
|
After the timeout expires, the device will continue
|
||
|
processing the job as if a continue event occurred, such
|
||
|
as the front panel continue key being pressed. If the
|
||
|
value is -1, the device does not automatically continue
|
||
|
after a job related continuable error occurs. If the
|
||
|
value is 0, the device immediately continues. If the
|
||
|
value is greater than 0, the value represents the
|
||
|
timeout value in seconds.
|
||
|
Additional information:
|
||
|
This object is used only for media requests
|
||
|
(size and/or name). LaserJet 4050 Series supports any value in
|
||
|
the range of -1 to 3600. Setting to a value outside
|
||
|
of that range causes the printer to substitute a
|
||
|
value (listed below) and to return
|
||
|
<noError> status. The
|
||
|
values are as follow: <-1 snaps to -1
|
||
|
>3600 snaps to 3600 (60 minutes) The action that
|
||
|
occurs when this timeout expires is explained by
|
||
|
JOB-INPUT-AUTO-CONTINUE-MODE. It is not the same as
|
||
|
the CONTINUE object being set to eInitiateAction or
|
||
|
the Select key being pressed on the control panel.
|
||
|
See the CONTINUE object description for
|
||
|
information on the actions that occur for those
|
||
|
conditions.
|
||
|
The data for this object is stored in NVRAM."
|
||
|
::= { status-system 35 }
|
||
|
|
||
|
|
||
|
job-input-auto-continue-mode OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the device behavior when the desired
|
||
|
media is not currently available.
|
||
|
cCancelJob - The device cancels the job. The device
|
||
|
POS should explain what happens if this item is not the
|
||
|
only item in the collection.
|
||
|
cAutoMediaSizeOverride - The device is allowed to
|
||
|
substitute a different size media.
|
||
|
cAutoMediaNameOverride - The device is allowed to
|
||
|
substitute a different media name.
|
||
|
Additional information:
|
||
|
If cCancelJob is set, the current print job will
|
||
|
be canceled regardless of other item settings. At
|
||
|
least one bit of the collection must be set; setting
|
||
|
this object to zero will cause a status of
|
||
|
<badValue> to be returned.
|
||
|
This object applies to all media requests, including
|
||
|
Manual Feed Requests. This object describes the
|
||
|
action that is performed when the
|
||
|
JOB-INPUT-AUTO-CONTINUE-TIMEOUT expires. The action
|
||
|
performed by the CONTINUE object being set to
|
||
|
eInitiateAction or the GO key being pressed on the
|
||
|
control panel may cause different actions. See the
|
||
|
CONTINUE object description for information on the
|
||
|
actions that occur for those conditions.
|
||
|
The data for this object is stored in NVRAM."
|
||
|
::= { status-system 36 }
|
||
|
|
||
|
|
||
|
job-output-auto-continue-timeout OBJECT-TYPE
|
||
|
SYNTAX INTEGER(-1..3600)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the time that the printer will wait
|
||
|
after an output bin becomes full and the printer is
|
||
|
trying to deliver a sheet of media to that output bin.
|
||
|
When the timeout expires, the job is processed according
|
||
|
to the OUTBINn-OVERRIDE-MODE. A value of -1 indicates
|
||
|
that the printer will wait for a continue event. A non-
|
||
|
negative value is the number of seconds to wait.
|
||
|
Additional information:
|
||
|
A value of zero means to continue immediately.
|
||
|
The value of this object is stored in NVRAM, so
|
||
|
it is maintained across a power cycle.
|
||
|
The data for this object is stored in NVRAM."
|
||
|
::= { status-system 40 }
|
||
|
|
||
|
|
||
|
phd2-model OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns product information identifying PHD device 2.
|
||
|
Additional information:
|
||
|
If at least one (1) external paper handling device
|
||
|
is attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns product information about the
|
||
|
first paper handling device in the device chain."
|
||
|
::= { phd2 1 }
|
||
|
|
||
|
|
||
|
phd2-manufacturing-info OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns information describing the manufacture of PHD 2.
|
||
|
May include serial number and firmware revision.
|
||
|
Additional information:
|
||
|
If at least one (1) external paper handling device
|
||
|
is attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns the name of the manufacturer of
|
||
|
the first paper handling device."
|
||
|
::= { phd2 2 }
|
||
|
|
||
|
|
||
|
phd2-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUnknown(2),
|
||
|
eInputPHD(10),
|
||
|
eOutputPHD(11),
|
||
|
eBindingPHD(13)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
PHD interface 2. See SIMM1-TYPE for an explanation of
|
||
|
the enumerations.
|
||
|
Additional information:
|
||
|
If at least one (1) external paper handling device
|
||
|
is attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns whether the device is an input
|
||
|
device, an output device, or an unknown device which may
|
||
|
be developed in the future."
|
||
|
::= { phd2 3 }
|
||
|
|
||
|
|
||
|
phd2-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of the installed
|
||
|
option. See SIMM1-CAPACITY for an explanation of the
|
||
|
meaning of the value of this object.
|
||
|
Additional information:
|
||
|
If at least one (1) external paper handling device
|
||
|
(EPHD) is attached to the printer, then this object
|
||
|
will exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns the number of input trays or
|
||
|
output bins, depending the the device type (see
|
||
|
PHD2-TYPE) for the first EPHD in the device chain."
|
||
|
::= { phd2 4 }
|
||
|
|
||
|
|
||
|
phd3-model OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns product information identifying PHD device 3.
|
||
|
Additional information:
|
||
|
If at least two (2) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns product information about the
|
||
|
second paper handling device in the device chain."
|
||
|
::= { phd3 1 }
|
||
|
|
||
|
|
||
|
phd3-manufacturing-info OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns information describing the manufacture of PHD 3.
|
||
|
May include serial number and firmware revision.
|
||
|
Additional information:
|
||
|
If at least two (2) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns the name of the manufacturer of
|
||
|
the second paper handling device."
|
||
|
::= { phd3 2 }
|
||
|
|
||
|
|
||
|
phd3-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUnknown(2),
|
||
|
eInputPHD(10),
|
||
|
eOutputPHD(11),
|
||
|
eBindingPHD(13)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
PHD interface 3. See SIMM1-TYPE for an explanation of
|
||
|
the enumerations.
|
||
|
Additional information:
|
||
|
If at least two (2) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns whether the second device is an
|
||
|
input device, an output device, or an unknown object which may
|
||
|
be developed in the future."
|
||
|
::= { phd3 3 }
|
||
|
|
||
|
|
||
|
phd3-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of the installed
|
||
|
option. See SIMM1-CAPACITY for an explanation of the
|
||
|
meaning of the value of this object.
|
||
|
Additional information:
|
||
|
If at least two (2) external paper handling devices
|
||
|
(EPHD) are attached to the printer, then this object
|
||
|
will exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns the number of input trays or
|
||
|
output bins, depending the the device type (see
|
||
|
PHD3-TYPE) for the second EPHD in the device chain."
|
||
|
::= { phd3 4 }
|
||
|
|
||
|
|
||
|
phd4-model OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns product information identifying PHD device 4.
|
||
|
Additional information:
|
||
|
If at least three (3) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns product information about the
|
||
|
third paper handling device in the device chain."
|
||
|
::= { phd4 1 }
|
||
|
|
||
|
|
||
|
phd4-manufacturing-info OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns information describing the manufacture of PHD 4.
|
||
|
May include serial number and firmware revision.
|
||
|
Additional information:
|
||
|
If at least three (3) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns the name of the manufacturer of
|
||
|
the third paper handling device."
|
||
|
::= { phd4 2 }
|
||
|
|
||
|
|
||
|
phd4-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUnknown(2),
|
||
|
eInputPHD(10),
|
||
|
eOutputPHD(11),
|
||
|
eBindingPHD(13)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
PHD interface 4. See SIMM1-TYPE for an explanation of
|
||
|
the enumerations.
|
||
|
Additional information:
|
||
|
If at least three (3) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns whether the third device is an
|
||
|
input device, an output device, or an unknown device which may
|
||
|
be developed in the future."
|
||
|
::= { phd4 3 }
|
||
|
|
||
|
|
||
|
phd4-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of the installed
|
||
|
option. See SIMM1-CAPACITY for an explanation of the
|
||
|
meaning of the value of this object.
|
||
|
Additional information:
|
||
|
If at least three (3) external paper handling devices
|
||
|
(EPHD) are attached to the printer, then this object
|
||
|
will exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns the number of input trays or
|
||
|
output bins, depending the the device type (see
|
||
|
PHD4-TYPE) for the third EPHD in the device chain."
|
||
|
::= { phd4 4 }
|
||
|
|
||
|
|
||
|
phd5-model OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns product information identifying PHD device 3.
|
||
|
Additional information:
|
||
|
If at least four (4) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns product information about the
|
||
|
fourth paper handling device in the device chain."
|
||
|
::= { phd5 1 }
|
||
|
|
||
|
|
||
|
phd5-manufacturing-info OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns information describing the manufacture of PHD 5.
|
||
|
May include serial number and firmware revision.
|
||
|
Additional information:
|
||
|
If at least four (4) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns the name of the manufacturer of
|
||
|
the fourth paper handling device."
|
||
|
::= { phd5 2 }
|
||
|
|
||
|
|
||
|
phd5-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUnknown(2),
|
||
|
eInputPHD(10),
|
||
|
eOutputPHD(11),
|
||
|
eBindingPHD(13)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
PHD interface 5. See SIMM1-TYPE for an explanation of
|
||
|
the enumerations.
|
||
|
Additional information:
|
||
|
If at least four (4) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns whether the fourth device is an
|
||
|
input device, an output device, or an unknown device which may
|
||
|
be developed in the future."
|
||
|
::= { phd5 3 }
|
||
|
|
||
|
|
||
|
phd5-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of the installed
|
||
|
option. See SIMM1-CAPACITY for an explanation of the
|
||
|
meaning of the value of this object.
|
||
|
Additional information:
|
||
|
If at least four (4) external paper handling devices
|
||
|
(EPHD) are attached to the printer, then this object
|
||
|
will exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns the number of input trays or
|
||
|
output bins, depending the the device type (see
|
||
|
PHD5-TYPE) for the fourth EPHD in the device chain."
|
||
|
::= { phd5 4 }
|
||
|
|
||
|
|
||
|
phd6-model OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns product information identifying PHD device 6.
|
||
|
Additional information:
|
||
|
If at least five (5) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns product information about the
|
||
|
fifth paper handling device in the device chain."
|
||
|
::= { phd6 1 }
|
||
|
|
||
|
|
||
|
phd6-manufacturing-info OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns information describing the manufacture of PHD 6.
|
||
|
May include serial number and firmware revision.
|
||
|
Additional information:
|
||
|
If at least five (5) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns the name of the manufacturer of
|
||
|
the fifth paper handling device."
|
||
|
::= { phd6 2 }
|
||
|
|
||
|
|
||
|
phd6-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUnknown(2),
|
||
|
eInputPHD(10),
|
||
|
eOutputPHD(11),
|
||
|
eBindingPHD(13)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
PHD interface 6. See SIMM1-TYPE for an explanation of
|
||
|
the enumerations.
|
||
|
Additional information:
|
||
|
If at least five (5) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns whether the fifth device is an
|
||
|
input device, an output device, or an unknown device which may
|
||
|
be developed in the future."
|
||
|
::= { phd6 3 }
|
||
|
|
||
|
|
||
|
phd6-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of the installed
|
||
|
option. See SIMM1-CAPACITY for an explanation of the
|
||
|
meaning of the value of this object.
|
||
|
Additional information:
|
||
|
If at least five (5) external paper handling devices
|
||
|
(EPHD) are attached to the printer, then this object
|
||
|
will exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns the number of input trays or
|
||
|
output bins, depending the the device type (see
|
||
|
PHD6-TYPE) for the fifth EPHD in the device chain."
|
||
|
::= { phd6 4 }
|
||
|
|
||
|
|
||
|
override-media-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Sets a string identifying the media name that is to be
|
||
|
used in place of the currently requested media. The
|
||
|
substitution will continue until another media is
|
||
|
selected. If set to a named media that is not currently
|
||
|
available the requested media is not overridden.
|
||
|
Additional information:
|
||
|
When a request is received to print on a size and
|
||
|
type of media that is not currently available, this
|
||
|
object contains the desired media name as set by the
|
||
|
print job. This object should be set to a media name
|
||
|
that is currently available in the printer. If a
|
||
|
paper mount request is not pending, attempting to get
|
||
|
or set this object will cause
|
||
|
<noSuchName> to be returned.
|
||
|
Setting this object to a string other than one of the
|
||
|
MEDIAn-NAME objects (MEDIA-NAMES-AVAILABLE is applied)
|
||
|
will cause a status of <badValue>
|
||
|
to be returned."
|
||
|
::= { settings-prt-eng 2 }
|
||
|
|
||
|
total-engine-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Total number of pages printed by the device. POS
|
||
|
indicates if the total engine page count is kept in
|
||
|
NVRAM, and the maximum supported value before the page
|
||
|
count rolls over to zero.
|
||
|
Additional information:
|
||
|
In LaserJet 4V the total engine page count is kept in
|
||
|
NVRAM however the NVRAM value is only updated every 10
|
||
|
pages. NOTE: The value returned by this OID will be
|
||
|
incremented every page but if power is lost between
|
||
|
NVRAM updates up to 9 pages of the page count may be
|
||
|
lost. The page count counter will be reset to zero
|
||
|
after 16,777,215 (2^24-1) pages."
|
||
|
::= { status-prt-eng 5 }
|
||
|
|
||
|
status-destination-print-engine OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if part of the print engine sub-system is not
|
||
|
functional, but the non-functional component(s) are not
|
||
|
currently required to print."
|
||
|
::= { status-prt-eng 8 }
|
||
|
|
||
|
duplex-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Total number of sheets of media that have been duplex
|
||
|
printed. A sheet is counted if it travels through the
|
||
|
duplex page path, regardless of whether or not marks are
|
||
|
made on the page. The POS will indicate if the value is
|
||
|
kept in NVRAM.
|
||
|
Additional information:
|
||
|
In LaserJet 4050 Series the count is kept in
|
||
|
NVRAM however the NVRAM value is only updated every 10
|
||
|
sheets. NOTE: The value returned by this object will be
|
||
|
incremented every sheet but if power is lost between
|
||
|
NVRAM updates up to 9 sheets of the count may be
|
||
|
lost. The counter will be reset to zero
|
||
|
after 16,777,215 (2^24-1) pages. "
|
||
|
::= { status-prt-eng 22 }
|
||
|
|
||
|
print-engine-revision OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..16))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Print engine revision string.
|
||
|
Additional information:
|
||
|
The symbol set for this string is Roman-8. Converts
|
||
|
engine revision number to a string and returns it."
|
||
|
::= { status-prt-eng 26 }
|
||
|
|
||
|
|
||
|
custom-paper-dim-unit OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eTenThousandthsOfInches(3),
|
||
|
eMicrometers(4)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The units of measure used to specify the width and
|
||
|
height of the printer's custom paper. The unit of
|
||
|
measure of eTenThousandthsOfInches is 0.0001 inches.
|
||
|
Additional information:
|
||
|
The only valid values for this object are
|
||
|
eTenThousandthsOfInches (3), and
|
||
|
eMicrometers (4).
|
||
|
The data for this object is stored in NVRAM."
|
||
|
::= { settings-intray 7 }
|
||
|
|
||
|
|
||
|
tray1-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this input tray.
|
||
|
Additional information:
|
||
|
The internal trays belong to device 0, which is the
|
||
|
base engine. The envelope feeder (if supported) is
|
||
|
considered to be device 1 and the external input devices
|
||
|
can number between 2 and 6 depending on individual
|
||
|
user configurations."
|
||
|
::= { intray1 12 }
|
||
|
|
||
|
tray1-fuser-temperature OBJECT-TYPE
|
||
|
SYNTAX INTEGER(-1..1)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The fuser temperature to be used when printing media
|
||
|
from Tray 1. The value zero is the default temperature.
|
||
|
Values less than zero are progressively lower and values
|
||
|
greater than zero are progressively higher. The range
|
||
|
of values supported is device specific.
|
||
|
Additional information:
|
||
|
HP LaserJet 2100 Series supports 3 fuser temperatures.
|
||
|
Zero (0) is the default temperature, one(1) is a higher
|
||
|
temperature (for use on media like cardstock), negative
|
||
|
one (-1) is a lower temperature (for use on media like
|
||
|
transparencies).
|
||
|
|
||
|
Setting to an unsupported value causes the printer to
|
||
|
snap to the nearest supported value and to return
|
||
|
<noError> status along with
|
||
|
the actual value that was written.
|
||
|
|
||
|
The snap values are as follows:
|
||
|
<=-1 snaps to -1
|
||
|
>=1 snaps to 1"
|
||
|
::= { intray1 13 }
|
||
|
|
||
|
overflow-bin OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the bin that will be used for additional
|
||
|
sheets of media when the current bin is full and
|
||
|
printing is allowed to continue.
|
||
|
Additional information:
|
||
|
The data for this object is stored in NVRAM."
|
||
|
::= { settings-outbin 4 }
|
||
|
|
||
|
|
||
|
outbin1-override-mode OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the device behavior when this output bin
|
||
|
condition causes printing to stop.
|
||
|
cCancelJob - The device cancels the job.
|
||
|
cOutbinFullOverride - The device sends subsequent
|
||
|
media to the overflow bin.
|
||
|
cOutbinAttentionOverride - The device ignores the
|
||
|
attention condition and continues printing.
|
||
|
cBinderAttentionOverride - The device ignores the
|
||
|
binder attention condition and continues printing.
|
||
|
Additional information:
|
||
|
If cCancelJob is set, the current print job will
|
||
|
be cancelled regardless of other item settings.
|
||
|
If cOutbinFullOverride is set and this bin is the
|
||
|
designated overflow bin (OVERFLOW-BIN = 1), then the
|
||
|
bit is ignored. This object describes the action
|
||
|
that is performed when the
|
||
|
JOB-OUTPUT-AUTO-CONTINUE-TIMEOUT expires. If no bits
|
||
|
are set, no override action is taken (the printer
|
||
|
will continue to wait).
|
||
|
The action performed by the CONTINUE object being set
|
||
|
to eInitiateAction or the GO key being pressed on the
|
||
|
control panel may cause different actions. See the
|
||
|
CONTINUE object
|
||
|
description for information on the actions that occur
|
||
|
for those conditions."
|
||
|
::= { outbin1 9 }
|
||
|
|
||
|
outbin1-maximum-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Maximum capacity of the output bin, in sheets of 20
|
||
|
pound paper."
|
||
|
::= { outbin1 1 }
|
||
|
|
||
|
outbin2-override-mode OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the device behavior when this output bin
|
||
|
condition causes printing to stop.
|
||
|
cCancelJob - The device cancels the job.
|
||
|
cOutbinFullOverride - The device sends subsequent
|
||
|
media to the overflow bin.
|
||
|
cOutbinAttentionOverride - The device ignores the
|
||
|
attention condition and continues printing.
|
||
|
cBinderAttentionOverride - The device ignores the
|
||
|
binder attention condition and continues printing.
|
||
|
Additional information:
|
||
|
See OUTBIN1-OVERRIDE-MODE."
|
||
|
::= { outbin2 9 }
|
||
|
|
||
|
phd2-device-specific-command OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object is used to send device-specific data to the
|
||
|
paper handling device. The meaning of the device-
|
||
|
specific command is dependent on the paper handling
|
||
|
device and must be specified in the POS.
|
||
|
If the paper handling device does not accept the
|
||
|
command, then an <badValue> will
|
||
|
be returned. If the device accepts the command, it may
|
||
|
still be processing the command after the response has
|
||
|
been returned. Depending on the device, the application
|
||
|
may need to query PHDx-DEVICE-MEMORY to see when the
|
||
|
command has completed.
|
||
|
Additional information:
|
||
|
If at least one (1) external paper handling device
|
||
|
is attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
will be returned.
|
||
|
Since the data formats can vary from device to
|
||
|
device, this information must be documented for
|
||
|
each device by the manufacturer of the device.
|
||
|
If the device does not support this command, then
|
||
|
an <badValue> error message
|
||
|
will be returned.
|
||
|
Since it will usually take longer to send this
|
||
|
command to the device than PML allows for <Set>
|
||
|
operations, this object will have a return value
|
||
|
that does not necessarily match the value currently
|
||
|
received by the first device."
|
||
|
::= { ph2 2 }
|
||
|
|
||
|
|
||
|
phd2-device-memory OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object is used to read the current values stored in
|
||
|
shared memory available from the paper handling device.
|
||
|
Additional information:
|
||
|
If at least one (1) external paper handling device
|
||
|
is attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns the current memory stored in
|
||
|
the printer's NVRAM (non-volatile RAM) for the
|
||
|
first paper handling device. Currently, the
|
||
|
printer allocates 16 bytes for each device."
|
||
|
::= { ph2 4 }
|
||
|
|
||
|
|
||
|
phd3-device-specific-command OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object is used to send device-specific data to the
|
||
|
paper handling device. The meaning of the device-
|
||
|
specific command is dependent on the paper handling
|
||
|
device and must be specified in the POS.
|
||
|
If the paper handling device does not accept the
|
||
|
command, then an <badValue> will
|
||
|
be returned. If the device accepts the command, it may
|
||
|
still be processing the command after the response has
|
||
|
been returned. Depending on the device, the application
|
||
|
may need to query PHDx-DEVICE-MEMORY to see when the
|
||
|
command has completed.
|
||
|
Additional information:
|
||
|
If at least two (2) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
will be returned.
|
||
|
Since the data formats can vary from device to
|
||
|
device, this information must be documented for
|
||
|
each device by the manufacturer of the device.
|
||
|
If the device does not support this command, then
|
||
|
an <badValue> error message
|
||
|
will be returned.
|
||
|
Since it will usually take longer to send this
|
||
|
command to the device than PML allows for <Set>
|
||
|
operations, this object will have a return value
|
||
|
that does not necessarily match the value currently
|
||
|
received by the second device."
|
||
|
::= { ph3 2 }
|
||
|
|
||
|
|
||
|
phd3-device-memory OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object is used to read the current values stored in
|
||
|
shared memory available from the paper handling device.
|
||
|
Additional information:
|
||
|
If at least two (2) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns the current memory stored in
|
||
|
the printer's NVRAM (non-volatile RAM) for the
|
||
|
second paper handling device. Currently, the
|
||
|
printer allocates 16 bytes for each device."
|
||
|
::= { ph3 4 }
|
||
|
|
||
|
|
||
|
phd4-device-specific-command OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object is used to send device-specific data to the
|
||
|
paper handling device. The meaning of the device-
|
||
|
specific command is dependent on the paper handling
|
||
|
device and must be specified in the POS.
|
||
|
If the paper handling device does not accept the
|
||
|
command, then an <badValue> will
|
||
|
be returned. If the device accepts the command, it may
|
||
|
still be processing the command after the response has
|
||
|
been returned. Depending on the device, the application
|
||
|
may need to query PHDx-DEVICE-MEMORY to see when the
|
||
|
command has completed.
|
||
|
Additional information:
|
||
|
If at least three (3) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
will be returned.
|
||
|
Since the data formats can vary from device to
|
||
|
device, this information must be documented for
|
||
|
each device by the manufacturer of the device.
|
||
|
If the device does not support this command, then
|
||
|
an <badValue> error message
|
||
|
will be returned.
|
||
|
Since it will usually take longer to send this
|
||
|
command to the device than PML allows for <Set>
|
||
|
operations, this object will have a return value
|
||
|
that does not necessarily match the value currently
|
||
|
received by the third device."
|
||
|
::= { ph4 2 }
|
||
|
|
||
|
|
||
|
phd4-device-memory OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object is used to read the current values stored in
|
||
|
shared memory available from the paper handling device.
|
||
|
Additional information:
|
||
|
If at least three (3) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns the current memory stored in
|
||
|
the printer's NVRAM (non-volatile RAM) for the
|
||
|
second paper handling device. Currently, the
|
||
|
printer allocates 16 bytes for each device."
|
||
|
::= { ph4 4 }
|
||
|
|
||
|
|
||
|
phd5-device-specific-command OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object is used to send device-specific data to the
|
||
|
paper handling device. The meaning of the device-
|
||
|
specific command is dependent on the paper handling
|
||
|
device and must be specified in the POS.
|
||
|
If the paper handling device does not accept the
|
||
|
command, then an <badValue> will
|
||
|
be returned. If the device accepts the command, it may
|
||
|
still be processing the command after the response has
|
||
|
been returned. Depending on the device, the application
|
||
|
may need to query PHDx-DEVICE-MEMORY to see when the
|
||
|
command has completed.
|
||
|
Additional information:
|
||
|
If at least four (4) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
will be returned.
|
||
|
Since the data formats can vary from device to
|
||
|
device, this information must be documented for
|
||
|
each device by the manufacturer of the device.
|
||
|
If the device does not support this command, then
|
||
|
an <badValue> error message
|
||
|
will be returned.
|
||
|
Since it will usually take longer to send this
|
||
|
command to the device than PML allows for <Set>
|
||
|
operations, this object will have a return value
|
||
|
that does not necessarily match the value currently
|
||
|
received by the fourth device."
|
||
|
::= { ph5 2 }
|
||
|
|
||
|
|
||
|
phd5-device-memory OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object is used to read the current values stored in
|
||
|
shared memory available from the paper handling device.
|
||
|
Additional information:
|
||
|
If at least four (4) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns the current memory stored in
|
||
|
the printer's NVRAM (non-volatile RAM) for the
|
||
|
second paper handling device. Currently, the
|
||
|
printer allocates 16 bytes for each device."
|
||
|
::= { ph5 4 }
|
||
|
|
||
|
|
||
|
phd6-device-specific-command OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object is used to send device-specific data to the
|
||
|
paper handling device. The meaning of the device-
|
||
|
specific command is dependent on the paper handling
|
||
|
device and must be specified in the POS.
|
||
|
If the paper handling device does not accept the
|
||
|
command, then an <badValue> will
|
||
|
be returned. If the device accepts the command, it may
|
||
|
still be processing the command after the response has
|
||
|
been returned. Depending on the device, the application
|
||
|
may need to query PHDx-DEVICE-MEMORY to see when the
|
||
|
command has completed.
|
||
|
Additional information:
|
||
|
If at least five (5) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
will be returned.
|
||
|
Since the data formats can vary from device to
|
||
|
device, this information must be documented for
|
||
|
each device by the manufacturer of the device.
|
||
|
If the device does not support this command, then
|
||
|
an <badValue> error message
|
||
|
will be returned.
|
||
|
Since it will usually take longer to send this
|
||
|
command to the device than PML allows for <Set>
|
||
|
operations, this object will have a return value
|
||
|
that does not necessarily match the value currently
|
||
|
received by the fifth device."
|
||
|
::= { ph6 2 }
|
||
|
|
||
|
|
||
|
phd6-device-memory OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object is used to read the current values stored in
|
||
|
shared memory available from the paper handling device.
|
||
|
Additional information:
|
||
|
If at least five (5) external paper handling devices
|
||
|
are attached to the printer, then this object will
|
||
|
exist, otherwise <noSuchName>
|
||
|
should be returned.
|
||
|
This object returns the current memory stored in
|
||
|
the printer's NVRAM (non-volatile RAM) for the
|
||
|
second paper handling device. Currently, the
|
||
|
printer allocates 16 bytes for each device."
|
||
|
::= { ph6 4 }
|
||
|
|
||
|
|
||
|
north-edge-offset OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the number of 300 dpi dots by which the
|
||
|
image is shifted. Shift is relative to the leading edge
|
||
|
of the medium as the medium flows through the marking
|
||
|
engine with the side to be imaged facing the observer.
|
||
|
The leading edge is the North edge and the other edges
|
||
|
are defined by the normal compass layout of directions
|
||
|
with the compass facing the observer. The adjustment is
|
||
|
for all pages printed. A positive value moves the
|
||
|
image away from the leading edge of the medium. A
|
||
|
negative value moves the image closer to the leading
|
||
|
edge of the medium. The value 0 will return the image to
|
||
|
its factory default position.
|
||
|
Additional information:
|
||
|
The value of this object is stored in NVRAM."
|
||
|
::= { settings-print-media 2 }
|
||
|
|
||
|
|
||
|
media1-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 1 name.
|
||
|
Additional information:
|
||
|
The symbol set for this string is Roman-8."
|
||
|
::= { media1 1 }
|
||
|
|
||
|
|
||
|
media1-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 1. The
|
||
|
length restriction is required to allow the media name
|
||
|
to be displayed on the device's control panel. The
|
||
|
device POS must state the maximum number of characters
|
||
|
allowed. If the device also has a limitation on what
|
||
|
characters in a character set can be used (e.g. only
|
||
|
uppercase characters allowed), the POS should also state
|
||
|
character restrictions.
|
||
|
Additional information:
|
||
|
The maximum supported string length is 9 characters. If
|
||
|
the user entered string is too long, the device will store
|
||
|
the first 9 characters and will return the
|
||
|
<noError> status.
|
||
|
The characters must be in the range 20H to 7FH except 5C
|
||
|
cannot be used. The default symbol set is Roman-8 for
|
||
|
English; additional legal symbol sets are ISOLatin5,
|
||
|
ISOLatin2 and Windows31J. Setting this object with characters
|
||
|
outside of the range or of an illegal symbol set will cause an
|
||
|
error status of <badValue> to be returned."
|
||
|
::= { media1 2 }
|
||
|
|
||
|
|
||
|
media1-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 1 that have been printed. The
|
||
|
device POS should state whether this value is lost
|
||
|
across a power cycle or kept in NVRAM.
|
||
|
Additional information:
|
||
|
For LaserJet 4050 Series this page count is saved in NVRAM after every 10
|
||
|
pages. The maximum value is 4,294,967,295 which will never be reached in
|
||
|
normal operation.
|
||
|
The page count is incremented when a sheet of media is pulled from an input
|
||
|
tray. A duplex printed sheet will cause this counter to be incremented by
|
||
|
one.
|
||
|
The data for this object is stored in NVRAM."
|
||
|
::= { media1 3 }
|
||
|
|
||
|
|
||
|
media1-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
The engine processing characteristics that are to
|
||
|
be applied to this media type. Currently, 'engine
|
||
|
processing characteristics' denotes changes to
|
||
|
fusing temperature and/or transfer roller voltage.
|
||
|
The data for this object is stored in NVRAM."
|
||
|
::= { media1 4 }
|
||
|
|
||
|
|
||
|
media2-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 2 name.
|
||
|
Additional information:
|
||
|
See MEDIA1-NAME."
|
||
|
::= { media2 1 }
|
||
|
|
||
|
|
||
|
media2-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 2. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-SHORT-NAME."
|
||
|
::= { media2 2 }
|
||
|
|
||
|
|
||
|
media2-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 2 that have been printed. See
|
||
|
MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-PAGE-COUNT."
|
||
|
::= { media2 3 }
|
||
|
|
||
|
|
||
|
media2-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media2 4 }
|
||
|
|
||
|
|
||
|
media3-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 3 name.
|
||
|
Additional information:
|
||
|
See MEDIA1-NAME."
|
||
|
::= { media3 1 }
|
||
|
|
||
|
|
||
|
media3-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 3. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-SHORT-NAME."
|
||
|
::= { media3 2 }
|
||
|
|
||
|
|
||
|
media3-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 3 that have been printed. See
|
||
|
MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-PAGE-COUNT."
|
||
|
::= { media3 3 }
|
||
|
|
||
|
|
||
|
media3-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media3 4 }
|
||
|
|
||
|
|
||
|
media4-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 4 name.
|
||
|
Additional information:
|
||
|
See MEDIA1-NAME."
|
||
|
::= { media4 1 }
|
||
|
|
||
|
|
||
|
media4-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 4. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-SHORT-NAME."
|
||
|
::= { media4 2 }
|
||
|
|
||
|
|
||
|
media4-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 4 that have been printed. See
|
||
|
MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-PAGE-COUNT."
|
||
|
::= { media4 3 }
|
||
|
|
||
|
|
||
|
media5-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 5 name.
|
||
|
Additional information:
|
||
|
See MEDIA1-NAME."
|
||
|
::= { media5 1 }
|
||
|
|
||
|
|
||
|
media5-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 5. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-SHORT-NAME."
|
||
|
::= { media5 2 }
|
||
|
|
||
|
|
||
|
media5-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 5 that have been printed. See
|
||
|
MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-PAGE-COUNT."
|
||
|
::= { media5 3 }
|
||
|
|
||
|
|
||
|
media5-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media5 4 }
|
||
|
|
||
|
|
||
|
media6-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 6 name.
|
||
|
Additional information:
|
||
|
See MEDIA1-NAME."
|
||
|
::= { media6 1 }
|
||
|
|
||
|
|
||
|
media6-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 6. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-SHORT-NAME."
|
||
|
::= { media6 2 }
|
||
|
|
||
|
|
||
|
media6-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 6 that have been printed. See
|
||
|
MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-PAGE-COUNT."
|
||
|
::= { media6 3 }
|
||
|
|
||
|
|
||
|
media7-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 7 name.
|
||
|
Additional information:
|
||
|
See MEDIA1-NAME."
|
||
|
::= { media7 1 }
|
||
|
|
||
|
|
||
|
media7-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 7. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-SHORT-NAME."
|
||
|
::= { media7 2 }
|
||
|
|
||
|
|
||
|
media7-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 7 that have been printed. See
|
||
|
MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-PAGE-COUNT."
|
||
|
::= { media7 3 }
|
||
|
|
||
|
|
||
|
media7-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media7 4 }
|
||
|
|
||
|
|
||
|
media8-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 8 name.
|
||
|
Additional information:
|
||
|
See MEDIA1-NAME."
|
||
|
::= { media8 1 }
|
||
|
|
||
|
|
||
|
media8-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 8. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-SHORT-NAME."
|
||
|
::= { media8 2 }
|
||
|
|
||
|
|
||
|
media8-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 8 that have been printed. See
|
||
|
MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-PAGE-COUNT."
|
||
|
::= { media8 3 }
|
||
|
|
||
|
|
||
|
media8-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media8 4 }
|
||
|
|
||
|
|
||
|
media9-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 9 name.
|
||
|
Additional information:
|
||
|
See MEDIA1-NAME."
|
||
|
::= { media9 1 }
|
||
|
|
||
|
|
||
|
media9-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 9. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-SHORT-NAME."
|
||
|
::= { media9 2 }
|
||
|
|
||
|
|
||
|
media9-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 9 that have been printed. See
|
||
|
MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-PAGE-COUNT."
|
||
|
::= { media9 3 }
|
||
|
|
||
|
|
||
|
media9-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media9 4 }
|
||
|
|
||
|
|
||
|
media10-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 10 name.
|
||
|
Additional information:
|
||
|
See MEDIA1-NAME."
|
||
|
::= { media10 1 }
|
||
|
|
||
|
|
||
|
media10-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 10. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-SHORT-NAME."
|
||
|
::= { media10 2 }
|
||
|
|
||
|
|
||
|
media10-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 10 that have been printed.
|
||
|
See MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-PAGE-COUNT."
|
||
|
::= { media10 3 }
|
||
|
|
||
|
|
||
|
media11-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 11 name.
|
||
|
Additional information:
|
||
|
See MEDIA1-NAME."
|
||
|
::= { media11 1 }
|
||
|
|
||
|
|
||
|
media11-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 11. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-SHORT-NAME."
|
||
|
::= { media11 2 }
|
||
|
|
||
|
|
||
|
media11-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 11 that have been printed.
|
||
|
See MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-PAGE-COUNT."
|
||
|
::= { media11 3 }
|
||
|
|
||
|
media12-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 12 name.
|
||
|
Additional information:
|
||
|
See MEDIA1-NAME."
|
||
|
::= { media12 1 }
|
||
|
|
||
|
|
||
|
media12-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 12. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-SHORT-NAME."
|
||
|
::= { media12 2 }
|
||
|
|
||
|
|
||
|
media12-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 12 that have been printed.
|
||
|
See MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-PAGE-COUNT."
|
||
|
::= { media12 3 }
|
||
|
|
||
|
|
||
|
media12-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media12 4 }
|
||
|
|
||
|
|
||
|
media13-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 13 name.
|
||
|
Additional information:
|
||
|
The maximum supported string length is 24
|
||
|
bytes. If the user entered string is too long,
|
||
|
the device will store the first 24 bytes and
|
||
|
return the <noError> status.
|
||
|
See CAUTION statement under Product Specific Use."
|
||
|
::= { media13 1 }
|
||
|
|
||
|
|
||
|
media13-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 13. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
The maximum supported string length is 9 characters. If
|
||
|
the user entered string is too long, the device will store
|
||
|
the first 9 characters and will return the
|
||
|
<noError> status.
|
||
|
The characters must be in the range 20H to 7FH except 5C
|
||
|
cannot be used. The default symbol set is Roman-8 for
|
||
|
English; additional legal symbol sets are ISOLatin5,
|
||
|
ISOLatin2 and Windows31J. Setting this object with characters
|
||
|
outside of the range or of an illegal symbol set will cause an
|
||
|
error status of <badValue> to be returned."
|
||
|
::= { media13 2 }
|
||
|
|
||
|
|
||
|
media13-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 13 that have been printed.
|
||
|
See MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA1-PAGE-COUNT."
|
||
|
::= { media13 3 }
|
||
|
|
||
|
|
||
|
media13-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media13 4 }
|
||
|
|
||
|
|
||
|
media14-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 14 name.
|
||
|
Additional information:
|
||
|
See MEDIA13-NAME."
|
||
|
::= { media14 1 }
|
||
|
|
||
|
|
||
|
media14-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 14. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
See MEDIA13-SHORT-NAME."
|
||
|
::= { media14 2 }
|
||
|
|
||
|
|
||
|
media14-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 14 that have been printed.
|
||
|
See MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA13-PAGE-COUNT."
|
||
|
::= { media14 3 }
|
||
|
|
||
|
|
||
|
media14-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media14 4 }
|
||
|
|
||
|
|
||
|
media15-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 15 name.
|
||
|
Additional information:
|
||
|
See MEDIA13-NAME."
|
||
|
::= { media15 1 }
|
||
|
|
||
|
|
||
|
media15-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 15. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
See MEDIA13-SHORT-NAME."
|
||
|
::= { media15 2 }
|
||
|
|
||
|
|
||
|
media15-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 15 that have been printed.
|
||
|
See MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA13-PAGE-COUNT."
|
||
|
::= { media15 3 }
|
||
|
|
||
|
|
||
|
media15-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media15 4 }
|
||
|
|
||
|
|
||
|
media16-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 16 name.
|
||
|
Additional information:
|
||
|
See MEDIA13-NAME."
|
||
|
::= { media16 1 }
|
||
|
|
||
|
|
||
|
media16-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 16. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
See MEDIA13-SHORT-NAME."
|
||
|
::= { media16 2 }
|
||
|
|
||
|
|
||
|
media16-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 16 that have been printed.
|
||
|
See MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA13-PAGE-COUNT."
|
||
|
::= { media16 3 }
|
||
|
|
||
|
|
||
|
media16-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media16 4 }
|
||
|
|
||
|
|
||
|
media17-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..24))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Media 17 name.
|
||
|
Additional information:
|
||
|
See MEDIA13-NAME."
|
||
|
::= { media17 1 }
|
||
|
|
||
|
|
||
|
media17-short-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..9))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Length restricted version of the media name 17. See
|
||
|
MEDIA1-SHORT-NAME for details.
|
||
|
Additional information:
|
||
|
See MEDIA13-SHORT-NAME."
|
||
|
::= { media17 2 }
|
||
|
|
||
|
|
||
|
media17-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of sheets of media 17 that have been printed.
|
||
|
See MEDIA1-PAGE-COUNT for details.
|
||
|
Additional information:
|
||
|
See MEDIA13-PAGE-COUNT."
|
||
|
::= { media17 3 }
|
||
|
|
||
|
|
||
|
media17-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media17 4 }
|
||
|
|
||
|
|
||
|
prtinputdefaultindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of prtInputIndex corresponding to the default input
|
||
|
sub-unit: that is, this object selects the default source of
|
||
|
input media.
|
||
|
This value shall be -1 if there is no default input subunit specified
|
||
|
for the printer as a whole. In this case, the actual default
|
||
|
input subunit may be specified by means outside the scope of this
|
||
|
MIB, such as by each interpreter in a printer with multiple
|
||
|
interpreters.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The default input tray is determined by the printer
|
||
|
based on DEFAULT-MEDIA-SIZE and DEFAULT-MEDIA-NAME, and whether or
|
||
|
not optional trays are installed.
|
||
|
If Tray 1 is set in FIRST mode then the size of paper loaded in
|
||
|
Tray 1 is assumed to be the requested size. In this case, the printer will
|
||
|
pick from Tray 1 without regard to the requested size unless the
|
||
|
print job's paper size, paper type and tray designations exactly
|
||
|
match the configuration of another tray; in that case, the requested
|
||
|
tray will be picked."
|
||
|
::= { prtGeneralEntry 6 }
|
||
|
|
||
|
|
||
|
prtmarkerdefaultindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER(1..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of prtMarkerIndex corresponding to the
|
||
|
default marker sub-unit; that is, this object selects the
|
||
|
default marker.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4050 Series only has one marker subunit."
|
||
|
::= { prtGeneralEntry 8 }
|
||
|
|
||
|
|
||
|
prtmediapathdefaultindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER(1..3)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of prtMediaPathIndex corresponding to
|
||
|
the default media path; that is, the selection of the
|
||
|
default media path.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
If the duplex unit is not installed, the only valid
|
||
|
value for this object is 1; with duplex unit installed,
|
||
|
1-3 values are valid. 1 is simplex, 2 is
|
||
|
LongEdgeBindingDuplex, and 3 is ShortEdgeBindingDuplex.
|
||
|
If the printer is not idle, the new value of this object
|
||
|
may not take effect until a job boundary is reached.
|
||
|
If a get is done on this object before the job boundary
|
||
|
is reached, the value last set will be returned."
|
||
|
::= { prtGeneralEntry 9 }
|
||
|
|
||
|
|
||
|
prtcoverdescription OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The manufacturer provided cover sub-mechanism name in the
|
||
|
localization specified by prtGeneralCurrentLocalization.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtCoverEntry 2 }
|
||
|
|
||
|
|
||
|
prtcoverstatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePdoorOpen(3),
|
||
|
ePdoorClosed(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The status of this cover sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML NOT-READY-DOOR-OPEN."
|
||
|
::= { prtCoverEntry 3 }
|
||
|
|
||
|
|
||
|
prtmarkermarktech OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePelectrophotographicLaser(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The type of marking technology used for this marking sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
ePelectrophotographicLaser is the only value that applies
|
||
|
for the LaserJet 4050 Series products, and this is the value that will
|
||
|
always be returned for this object."
|
||
|
::= { prtMarkerEntry 2 }
|
||
|
|
||
|
|
||
|
prtmarkercounterunit OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePimpressions(7)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The unit that will be used by the printer when reporting
|
||
|
counter values for this marking sub-unit. The
|
||
|
time units of measure are provided for a device like a
|
||
|
strip recorder that does not or cannot track the physical
|
||
|
dimensions of the media and does not use characters,
|
||
|
lines or sheets.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Since LaserJet 4050 Series keeps track of pages printed, the
|
||
|
counter unit will be defined as ePimpressions which would be
|
||
|
like saying pages printed."
|
||
|
::= { prtMarkerEntry 3 }
|
||
|
|
||
|
|
||
|
prtmarkerlifecount OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The count of the number of units of measure counted during
|
||
|
the life of printer using units of measure as specified by
|
||
|
prtMarkerCounterUnit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML TOTAL-ENGINE-PAGE-COUNT.
|
||
|
The total engine page count is kept in NVRAM however
|
||
|
the NVRAM value is only updated every 10 impressions.
|
||
|
NOTE: The value returned by this OID will be incremented
|
||
|
every page but if power is lost between NVRAM updates,
|
||
|
up to 9 impressions of the page count may be lost. The
|
||
|
counter will be reset to zero after 999999 pages.
|
||
|
The page count is incremented when a sheet of media is
|
||
|
pulled from an input tray. A duplex printed sheet will
|
||
|
cause this counter to be incremented by two."
|
||
|
::= { prtMarkerEntry 4 }
|
||
|
|
||
|
|
||
|
prtmarkerpoweroncount OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The count of the number of units of measure counted since the
|
||
|
equipment was most recently powered on using units of measure as
|
||
|
specified by prtMarkerCounterUnit.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtMarkerEntry 5 }
|
||
|
|
||
|
|
||
|
prtmarkerprocesscolorants OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of process colors supported by this marker. A
|
||
|
process color of 1 implies monochrome. The value of this
|
||
|
object and prtMarkerSpotColorants cannot both be 0. The value of
|
||
|
prtMarkerProcessColorants must be 0 or greater.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtMarkerEntry 6 }
|
||
|
|
||
|
|
||
|
prtmarkerspotcolorants OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of spot colors supported by this marker. The
|
||
|
value of this object and prtMarkerProcessColorants cannot
|
||
|
both be 0. Must be 0 or greater.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtMarkerEntry 7 }
|
||
|
|
||
|
|
||
|
prtmarkeraddressabilityunit OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePtenThousandthsOfInches(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The unit of measure of distances, as applied to the marker's
|
||
|
resolution.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
This will always be ePtenThousandthsOfInches, no matter
|
||
|
what COLD-RESET-MEDIA-SIZE is because we are talking about
|
||
|
resolution and toner addressability, which is always dpi."
|
||
|
::= { prtMarkerEntry 8 }
|
||
|
|
||
|
|
||
|
prtmarkernorthmargin OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The margin, in units identified by prtMarkerAddressabilityUnit,
|
||
|
from the leading edge of the medium as the medium flows
|
||
|
through the marking engine with the side to be imaged
|
||
|
facing the observer. The leading edge is the North edge
|
||
|
and the other edges are defined by the normal compass
|
||
|
layout of directions with the compass facing the
|
||
|
observer. Printing within the area bounded by all four
|
||
|
margins is guaranteed for all interpreters. The value
|
||
|
(-2) means unknown.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtMarkerEntry 11 }
|
||
|
|
||
|
|
||
|
prtmarkersouthmargin OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The margin from the South edge (see prtMarkerNorthMargin)
|
||
|
of the medium in units identified by
|
||
|
prtMarkerAddressabilityUnit. Printing within the area bounded by
|
||
|
all four margins is guaranteed for all interpreters.
|
||
|
The value (-2) means unknown.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtMarkerEntry 12 }
|
||
|
|
||
|
|
||
|
prtmarkerwestmargin OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The margin from the West edge (see prtMarkerNorthMargin) of the
|
||
|
medium in units identified by prtMarkerAddressabilityUnit.
|
||
|
Printing within the area bounded by all four margins is
|
||
|
guaranteed for all interpreters. The value (-2) means
|
||
|
unknown.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtMarkerEntry 13 }
|
||
|
|
||
|
|
||
|
prtmarkereastmargin OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The margin from the East edge (see prtMarkerNorthMargin) of the
|
||
|
medium in units identified by prtMarkerAddressabilityUnit.
|
||
|
Printing within the area bounded by all four margins is
|
||
|
guaranteed for all interpreters. The value (-2) means
|
||
|
unknown.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtMarkerEntry 14 }
|
||
|
|
||
|
|
||
|
prtmarkerstatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The current status of this marker sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML NOT-READY-DESTINATION-PRINT-ENGINE and
|
||
|
STATUS-DESTINATION-PRINT-ENGINE.
|
||
|
51 = No toner cart.
|
||
|
49 = Low toner and toner low = stop in config menu
|
||
|
14 = Low toner and toner low = continue in config menu
|
||
|
and paper is moving.
|
||
|
08 = Low toner and toner low = continue in config menu
|
||
|
and no paper is moving.
|
||
|
00 = OK.
|
||
|
The default value assumes no malfunctions."
|
||
|
::= { prtMarkerEntry 15 }
|
||
|
|
||
|
|
||
|
prtmarkersuppliesmarkerindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of prtMarkerIndex corresponding to the
|
||
|
marking sub-unit with which this marker supply
|
||
|
sub-unit is associated.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4050 Series has just one marker supply, the toner
|
||
|
cartridge, so this value is always 1."
|
||
|
::= { prtMarkerSuppliesEntry 2 }
|
||
|
|
||
|
|
||
|
prtmarkersuppliescolorantindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of prtMarkerColorantIndex
|
||
|
corresponding to the colorant with which this
|
||
|
marker supply sub-unit is associated. This value
|
||
|
shall be 0 if there is no colorant table.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtMarkerSuppliesEntry 3 }
|
||
|
|
||
|
|
||
|
prtmarkersuppliesclass OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePsupplyThatIsConsumed(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates whether this supply entity represents a supply
|
||
|
that is consumed or a receptacle that is filled.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
ePsupplyThatIsConsumed is the only value that applies
|
||
|
for the LaserJet 4050 Series products, and this is the value that will
|
||
|
always be returned for this object."
|
||
|
::= { prtMarkerSuppliesEntry 4 }
|
||
|
|
||
|
|
||
|
prtmarkersuppliestype OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePtoner(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The type of this supply.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
ePtoner is the only value that applies for the LaserJet 4050 Series
|
||
|
products, and this is the value that will always be
|
||
|
returned for this object."
|
||
|
::= { prtMarkerSuppliesEntry 5 }
|
||
|
|
||
|
|
||
|
prtmarkersuppliessupplyunit OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePtenthsOfGrams(13)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Unit of measure of this marker supply container/receptacle.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
ePtenthsOfGrams will always be returned for this object."
|
||
|
::= { prtMarkerSuppliesEntry 7 }
|
||
|
|
||
|
|
||
|
prtmarkercolorantmarkerindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of prtMarkerIndex corresponding to the
|
||
|
marker sub-unit with which this colorant entry is
|
||
|
associated.
|
||
|
Additional information:
|
||
|
LaserJet 4500 only has one marker. Therefore, the
|
||
|
value of these objects is always 1."
|
||
|
::= { prtMarkerColorantEntry 2 }
|
||
|
|
||
|
|
||
|
prtmarkercolorantrole OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePprocess(3),
|
||
|
ePspot(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The role played by this colorant.
|
||
|
Additional information:
|
||
|
All LaserJet 4500 colorants are process colorants."
|
||
|
::= { prtMarkerColorantEntry 3 }
|
||
|
|
||
|
|
||
|
prtmarkercolorantvalue OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The name of the color of this
|
||
|
colorant using standardized string names from ISO 10175 (DPA)
|
||
|
and ISO 10180 (SPDL) which are:
|
||
|
other
|
||
|
unknown
|
||
|
white
|
||
|
red
|
||
|
green
|
||
|
blue
|
||
|
cyan
|
||
|
magenta
|
||
|
yellow
|
||
|
black
|
||
|
Implementors may add additional string values. The naming
|
||
|
conventions in ISO 9070 are recommended in order to avoid
|
||
|
potential name clashes"
|
||
|
::= { prtMarkerColorantEntry 4 }
|
||
|
|
||
|
|
||
|
prtmarkercoloranttonality OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The distinct levels of tonality realizable by a marking
|
||
|
sub-unit when using this colorant. This value does not
|
||
|
include the number of levels of tonal difference that an
|
||
|
interpreter can obtain by techniques such as half toning.
|
||
|
This value must be at least 2.
|
||
|
Additional information:
|
||
|
LaserJet 4500 supports eight bits per pixel."
|
||
|
::= { prtMarkerColorantEntry 5 }
|
||
|
|
||
|
|
||
|
|
||
|
prtmediapathmaxspeedprintunit OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePimpressionsPerHour(7)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The unit of measure used in specifying the speed of all media
|
||
|
paths in the printer.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
ePimpressionsPerHour is the value that will
|
||
|
always be returned for this object. (Print Speed is
|
||
|
measured in pages-per-minute (impressions per minute),
|
||
|
so ePimpressionsPerHour is a natural extension)."
|
||
|
::= { prtMediaPathEntry 2 }
|
||
|
|
||
|
|
||
|
prtmediapathmediasizeunit OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePtenThousandthsOfInches(3),
|
||
|
ePmicrometers(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The units of measure of media size for use in calculating and
|
||
|
relaying dimensional values for all media paths in the printer.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtMediaPathEntry 3 }
|
||
|
|
||
|
|
||
|
prtmediapathtype OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePlongEdgeBindingDuplex(3),
|
||
|
ePshortEdgeBindingDuplex(4),
|
||
|
ePsimplex(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The type of the media path for this media path.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML DUPLEX-INSTALLED."
|
||
|
::= { prtMediaPathEntry 9 }
|
||
|
|
||
|
|
||
|
prtmediapathdescription OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The manufacturer-provided description of this media path in
|
||
|
the localization specified by prtGeneralCurrentLocalization.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtMediaPathEntry 10 }
|
||
|
|
||
|
|
||
|
prtmediapathstatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The current status of this media path.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The default values assume the printer is idle."
|
||
|
::= { prtMediaPathEntry 11 }
|
||
|
|
||
|
|
||
|
collated-originals-support OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates that the printer can create multiple, collated
|
||
|
'originals' of a job and shows the level of support for
|
||
|
this capability.
|
||
|
cCollatedOriginals - The printer can create multiple
|
||
|
collated originals, or 'mopies'. This is the base
|
||
|
functionality required by the other collection items.
|
||
|
cProofAndHold - The printer saves a copy of the job
|
||
|
while printing the first mopy. Later, this held job can
|
||
|
be released and the rest of the mopies will print.
|
||
|
cSecurityPrint - The printer spools the job and holds
|
||
|
the job until the user releases the job by entering a
|
||
|
password at the printer's control panel.
|
||
|
cAutoHighlight - The printer prints the job a number
|
||
|
of times with a mail distribution list prepended to each
|
||
|
job. A different mailing address is highlighted on each
|
||
|
mopy.
|
||
|
cCollatedAtSpeed - The printer can create multiple
|
||
|
collated copies where all copies after the original are
|
||
|
printed at engine speed.
|
||
|
Additional information:
|
||
|
Indicates that the printer can create multiple, collated
|
||
|
originals of a job and shows the level of support for this
|
||
|
capability.
|
||
|
cCollatedOriginals - The printer can create multiple collated
|
||
|
originals, or mopies.
|
||
|
|
||
|
This is the base functionality required by the other
|
||
|
collection items. None of them are supported by Jonah.
|
||
|
Without disk, this object will not exist. This will be set at
|
||
|
boot-up initialization. If the disk fails, in any way, then
|
||
|
the disk error functionality will handle the situation.
|
||
|
|
||
|
The value of this object will be:
|
||
|
!cCollatedOriginals - Only FLASH installed
|
||
|
cCollatedOriginals - IDE is installed combined
|
||
|
with/without FLASH
|
||
|
cCollatedOriginals - RAMDISK is On combined with/without FLASH"
|
||
|
::= { status-system 42 }
|
||
|
|
||
|
|
||
|
file-system-memory OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The amount of memory, in bytes, used by the file system
|
||
|
to buffer file data.
|
||
|
Additional information:
|
||
|
Reports the amount of memory, in bytes,
|
||
|
reserved for use by the file system. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to access this object and there is no storage device
|
||
|
is installed. The values remain constant across reboots.
|
||
|
Possible Values:
|
||
|
FILE-SYSTEM-MAX-OPEN-FILES 32 512
|
||
|
EIO DISK 69916 198556
|
||
|
EIO DISK + 1 2MB Flash 88940 217580
|
||
|
1 2MB Flash 33052 161692"
|
||
|
::= { settings-file-system 1 }
|
||
|
|
||
|
|
||
|
file-system-test-return-code OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This test object that will not be supported in any
|
||
|
released product. Setting this object allows the next
|
||
|
file system call return code to be specified or to
|
||
|
simulate uninitialized or unistalled volumes. The POS
|
||
|
will specify the binary format.
|
||
|
Additional information:
|
||
|
A three byte binary value. The first
|
||
|
byte indicates what function is being effected by
|
||
|
this set.
|
||
|
value | function
|
||
|
------+------------------
|
||
|
1 | PersFSCtl
|
||
|
2 | PersFSDirClose
|
||
|
3 | PersFSDirCreate
|
||
|
4 | PersFSDirDelete
|
||
|
5 | PersFSDirOpen
|
||
|
6 | PersFSDirRead
|
||
|
7 | PersFSDirReadStd
|
||
|
8 | PersFSDirRewind
|
||
|
9 | PersFSDirSeek
|
||
|
10 | PersFSDirTell
|
||
|
11 | PersFSFileClose
|
||
|
12 | PersFSFileDelete
|
||
|
13 | PersFSFileMove
|
||
|
14 | PersFSFileOpen
|
||
|
15 | PersFSFileRead
|
||
|
16 | PersFSFileSeek
|
||
|
17 | PersFSFileStatus
|
||
|
18 | PersFSFileWrite
|
||
|
19 | PersFSFlush
|
||
|
20 | PersFSVolChk
|
||
|
21 | PersFSVolFix
|
||
|
22 | PersFSVolInit
|
||
|
23 | PersFSVolStatus
|
||
|
The return value of the function being effected will
|
||
|
return the value -1 to indicate an error occurred.
|
||
|
The second byte is the
|
||
|
value returned by the next call to PersFSErrNo()
|
||
|
(after the call being effected is called). Refer to
|
||
|
the 'Copernicus Personality Interface Volume 2 Disk
|
||
|
File System' documentation for a list of values
|
||
|
returned by PersFSErrNo(). The third byte indicates
|
||
|
which call to the specified file system routine will
|
||
|
fail. A value of one means the first call will fail.
|
||
|
A value of two means the second call will fail, and
|
||
|
so on. Writing this object causes any previous write to
|
||
|
this object to be invalidated.
|
||
|
Note: The error triggering
|
||
|
mechanism is actually implemented at the message
|
||
|
interface to the file system rather than at the PersFSxxx()
|
||
|
function call interface. This is easier to do, and
|
||
|
it is better for NFS because NFS uses the message
|
||
|
interface rather than the PersFSxxx() functions.
|
||
|
Fortunately there is a one-to-one mapping between
|
||
|
messages and PersFSxxx() functions so everything
|
||
|
works out nicely.
|
||
|
The printer will uninitialize the mass storage device if
|
||
|
the first byte is one of the values listed below.
|
||
|
value | meaning
|
||
|
------+------------------
|
||
|
101 | Effects the printer state
|
||
|
102 | Effects the data on the device
|
||
|
The Moby printer supports 3 volumes zero, so the
|
||
|
second byte must be 0 - 2. The third byte has no meaning
|
||
|
and must be zero."
|
||
|
::= { settings-file-system 3 }
|
||
|
|
||
|
|
||
|
file-system-statistic-read-open OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of times the file system has received
|
||
|
requests to open a file for reading. Opening a file for
|
||
|
both reading and writing will cause this value to
|
||
|
change. The POS should state if a power cycle causes
|
||
|
the counter is be reset to zero.
|
||
|
Additional information:
|
||
|
Reset to the factory default value after
|
||
|
a power cycle.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed. This value is
|
||
|
increamented when a file is opened."
|
||
|
::= { status-file-system 1 }
|
||
|
|
||
|
|
||
|
file-system-statistic-write-open OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of times the file system has received
|
||
|
requests to open a file for writing. Opening a file for
|
||
|
both reading and writing will cause this value to
|
||
|
change. The POS should state if a power cycle causes
|
||
|
the counter is be reset to zero.
|
||
|
Additional information:
|
||
|
Reset to the factory default value after
|
||
|
a power cycle.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed. This value is
|
||
|
increamented when a file is opened."
|
||
|
::= { status-file-system 2 }
|
||
|
|
||
|
|
||
|
file-system-statistic-successful OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A counter indicating the number of file system requests
|
||
|
that completed successfully. The POS should state if a
|
||
|
power cycle causes the counter is be reset to zero.
|
||
|
Additional information:
|
||
|
Reset to the factory default value after
|
||
|
a power cycle.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { status-file-system 3 }
|
||
|
|
||
|
|
||
|
file-system-statistic-unsuccessful OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A counter indicating the number of file system requests
|
||
|
that completed unsuccessfully. The POS should state if
|
||
|
a power cycle causes the counter is be reset to zero.
|
||
|
Additional information:
|
||
|
Reset to the factory default value after
|
||
|
a power cycle.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { status-file-system 4 }
|
||
|
|
||
|
|
||
|
file-system-statistic-current-memory-usage OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A value indicating the number of bytes of RAM currently
|
||
|
used by the file system firmware.
|
||
|
Additional information:
|
||
|
Reset to the factory default value after
|
||
|
a power cycle.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed. This will veri
|
||
|
depending on the number and size of Mass Storage
|
||
|
devices installed."
|
||
|
::= { status-file-system 5 }
|
||
|
|
||
|
|
||
|
file-system-statistic-max-memory-usage OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A value indicating the maximum number of bytes of RAM
|
||
|
used by the file system firmware. The POS should state
|
||
|
if the value is reset to zero after a power cycle.
|
||
|
Additional information:
|
||
|
Reset to the factory default value after
|
||
|
a power cycle.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { status-file-system 6 }
|
||
|
|
||
|
file-system1-initialized OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eFalse(1),
|
||
|
eTrue(2)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns eTrue if a file system has been written to the
|
||
|
mass storage device(s) which will hold file data
|
||
|
contained in this file system. Returns eFalse
|
||
|
otherwise. Each POS needs to specify the relationship
|
||
|
between file systems and the physical storage devices
|
||
|
that can hold the data contained in those file systems.
|
||
|
Additional information:
|
||
|
This objects is only supported if a disk is
|
||
|
installed.
|
||
|
Returns <noSuchName> status if
|
||
|
attempting to perform a Get on this OID with no disk
|
||
|
installed.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to perform a Set, EnableTrap, or
|
||
|
DisableTrap on this OID with no disk installed."
|
||
|
::= { file-system1 1 }
|
||
|
|
||
|
|
||
|
file-system1-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the total size, in bytes, of the mass storage
|
||
|
space configured to hold the file data (and file system
|
||
|
information) assoicated with files stored in this file
|
||
|
system. This refers to hardware capacity, independent
|
||
|
of any space consumed by the file system overhead or
|
||
|
user files.
|
||
|
Additional information:
|
||
|
This objects is only supported if a disk is
|
||
|
installed.
|
||
|
Returns <noSuchName> status if
|
||
|
attempting to perform a Get on this OID with no disk
|
||
|
installed.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to perform a Set, EnableTrap, or
|
||
|
DisableTrap on this OID with no disk installed."
|
||
|
::= { file-system1 2 }
|
||
|
|
||
|
|
||
|
file-system1-free-space OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the total amount, in bytes, of unused storage
|
||
|
space currently available to this file system.
|
||
|
Additional information:
|
||
|
This objects is only supported if a disk is
|
||
|
installed.
|
||
|
Returns <noSuchName> status if
|
||
|
attempting to perform a Get on this OID with no disk
|
||
|
installed.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to perform a Set, EnableTrap, or
|
||
|
DisableTrap on this OID with no disk installed."
|
||
|
::= { file-system1 3 }
|
||
|
|
||
|
|
||
|
file-system1-write-protect OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eDisabled(1),
|
||
|
eEnabled(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Supports write-protecting the file system. Setting
|
||
|
FILE-SYSTEM-WRITE-PROTECT to eEnabled blocks any
|
||
|
modification of the contents of the file system.
|
||
|
Setting FILE-SYSTEM-WRITE-PROTECT to eDisabled allows
|
||
|
modification of the contents of the file system.
|
||
|
Additional information:
|
||
|
This objects is only supported if a disk is
|
||
|
installed.
|
||
|
Returns <noSuchName> status if
|
||
|
attempting to perform a Get, or Set on this OID
|
||
|
with no disk installed.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to perform an EnableTrap, or
|
||
|
DisableTrap on this OID with no disk installed."
|
||
|
::= { file-system1 4 }
|
||
|
|
||
|
|
||
|
file-system2-initialize-volume OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eInitializing(2)
|
||
|
}
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Setting this object to eInitializing causes file system
|
||
|
2 to be initialized. Reading this object indicates if
|
||
|
the file system is currently being initialized.
|
||
|
Additional information:
|
||
|
The hrDeviceIndex value for the mass storage
|
||
|
device is the same value that is used to index into the
|
||
|
FILE-SYSTEM sub-tree. Since this product supports
|
||
|
up to 3 mass storage device, and since the hrDeviceIndex
|
||
|
for the mass storage devices will start at 2 if the mass
|
||
|
storage device is installed, the FILE-SYSTEM2-INITIALIZE-VOLUME
|
||
|
object will be the object that allows the mass storage device to be
|
||
|
initialized that is the 1st device."
|
||
|
::= { file-system2 6 }
|
||
|
|
||
|
|
||
|
file-system3-initialize-volume OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eInitializing(2)
|
||
|
}
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Setting this object to eInitializing causes file system
|
||
|
3 to be initialized. Reading this object indicates if
|
||
|
the file system is currently being initialized.
|
||
|
Additional information:
|
||
|
The hrDeviceIndex value for the mass storage
|
||
|
device is the same value that is used to index into the
|
||
|
FILE-SYSTEM sub-tree. Since this product supports
|
||
|
up to 3 mass storage device, and since the hrDeviceIndex
|
||
|
for the mass storage devices will start at 2 if the mass
|
||
|
storage device is installed, the FILE-SYSTEM3-INITIALIZE-VOLUME
|
||
|
object will be the object that allows the mass storage device to be
|
||
|
initialized that is the 2nd device."
|
||
|
::= { file-system3 6 }
|
||
|
|
||
|
|
||
|
file-system4-initialize-volume OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eInitializing(2)
|
||
|
}
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Setting this object to eInitializing causes file system
|
||
|
4 to be initialized. Reading this object indicates if
|
||
|
the file system is currently being initialized.
|
||
|
Additional information:
|
||
|
The hrDeviceIndex value for the mass storage
|
||
|
device is the same value that is used to index into the
|
||
|
FILE-SYSTEM sub-tree. Since this product supports
|
||
|
up to 3 mass storage devices, and since the hrDeviceIndex
|
||
|
for the mass storage devices will start at 2 if the mass
|
||
|
storage device is installed, the FILE-SYSTEM4-INITIALIZE-VOLUME
|
||
|
object will be the object that allows the mass storage device to be
|
||
|
initialized that is the 3rd device."
|
||
|
::= { file-system4 6 }
|
||
|
|
||
|
|
||
|
mass-storage-resource-change-counter OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A counter which changes when a mass storage based
|
||
|
resource has been added or deleted.
|
||
|
Additional information:
|
||
|
The value of this counter changes
|
||
|
each time the MASS-STORAGE-RESOURCE-CHANGED object
|
||
|
is set to eTrue. The value also changes when the
|
||
|
mass storage device is initialized. However, the value does not
|
||
|
change when a mass storage device is removed and a different
|
||
|
mass storage device is installed. Initializing all volumes sets
|
||
|
this object back to the factory default value. A reboot sets
|
||
|
this object back to the factory devalut value.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { mass-storage-resources 1 }
|
||
|
|
||
|
|
||
|
mass-storage-resource-changed OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eTrue(2)
|
||
|
}
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Setting to eTrue causes MASS-STORAGE-RESOURCE-CHANGE-
|
||
|
COUNTER to be incremented.
|
||
|
Additional information:
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { mass-storage-resources 2 }
|
||
|
|
||
|
|
||
|
hrstoragesize OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The size of the storage represented by this entry,
|
||
|
in units of hrStorageAllocationUnits.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information (printer):
|
||
|
Total formatter RAM.
|
||
|
Additional information (mass storage):
|
||
|
Applications can determine the size of the
|
||
|
installed mass storage device by getting the
|
||
|
hrStorageAllocationUnits object and this object. The size
|
||
|
of the mass storage device is these two returned values multiplied
|
||
|
together. Returns <noSuchName>
|
||
|
status if attempting to perform a Get on this OID
|
||
|
with no mass storage device installed."
|
||
|
::= { hrStorageEntry 5 }
|
||
|
|
||
|
|
||
|
hrdevicedescr OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..64))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A textual description of this device, including
|
||
|
the device's manufacturer and revision, and
|
||
|
optionally, its serial number.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information (printer) :
|
||
|
The serial number is not returned with this object.
|
||
|
This object is not localized.
|
||
|
Additional information (mass storage) :
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to perform a Get on this OID
|
||
|
with no mass storage device installed."
|
||
|
::= { hrDeviceEntry 3 }
|
||
|
|
||
|
|
||
|
hrdeviceid OBJECT-TYPE
|
||
|
SYNTAX OBJECT IDENTIFIER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The product ID for this device.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information (printer) :
|
||
|
The complete OID reported by this object is:
|
||
|
.1.3.6.1.4.1.11.2.3.9.1.2.12
|
||
|
Additional information (mass storage) :
|
||
|
Constant. Since we don't know all the
|
||
|
possible registered OIDs for each mass storage device model that
|
||
|
could be installed in this printer, this object
|
||
|
always returns the unknown product ID. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device
|
||
|
installed."
|
||
|
::= { hrDeviceEntry 4 }
|
||
|
|
||
|
|
||
|
hrdeviceerrors OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The number of errors detected on this device. It
|
||
|
should be noted that as this object has a SYNTAX
|
||
|
of Counter, that it does not have a defined
|
||
|
initial value. However, it is recommended that
|
||
|
this object be initialized to zero.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information (mass storage):
|
||
|
Total number of read and write errors
|
||
|
that have occurred since the printer was turned on.
|
||
|
Returns <noSuchName> status if
|
||
|
attempting to perform a Get on this OID with no mass storage device
|
||
|
installed. Returns 0 if the mass storage device is
|
||
|
uninitialized."
|
||
|
::= { hrDeviceEntry 6 }
|
||
|
|
||
|
|
||
|
hrdiskstorageaccess OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eHreadWrite(1),
|
||
|
eHreadOnly(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An indication if this long-term storage device is
|
||
|
readable and writable or only readable. This
|
||
|
should reflect the media type, any write-protect
|
||
|
mechanism, and any device configuration that
|
||
|
affects the entire device.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
This object can be set to write protect
|
||
|
the mass storage device, even though the host resources MIB
|
||
|
documents the object as read-only. Applications wanting to
|
||
|
know if the mass storage device is writable should get this
|
||
|
object. Applications wanting to change the read/write access
|
||
|
of the mass storage device should set this object.
|
||
|
If this object is set to write-protect while a file is being
|
||
|
written to the mass storage device, the write-protect takes effect
|
||
|
immediately and the new file doesn't appear in the file system.
|
||
|
Returns <noSuchName> status if attempting to
|
||
|
perform a Get on this OID with no mass storage device installed."
|
||
|
::= { hrDiskStorageEntry 1 }
|
||
|
|
||
|
|
||
|
hrdiskstoragemedia OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eHother(1),
|
||
|
eHhardDisk(3),
|
||
|
eHramDisk(8)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An indication of the type of media used in this
|
||
|
long-term storage device.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
Constant. Applications can determine if the
|
||
|
installed mass storage device is a disk or is flash by
|
||
|
getting this value.
|
||
|
Possible Values:
|
||
|
EIO DISK returns eHhardDisk
|
||
|
Ram Disk returns eHramDisk
|
||
|
Flash Disk returns eHother
|
||
|
Returns <noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device
|
||
|
installed."
|
||
|
::= { hrDiskStorageEntry 2 }
|
||
|
|
||
|
|
||
|
hrdiskstorageremoveble OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eHfalse(2)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Denotes whether or not the disk media may be
|
||
|
removed from the drive.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
Constant. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device
|
||
|
installed."
|
||
|
::= { hrDiskStorageEntry 3 }
|
||
|
|
||
|
|
||
|
hrdiskstoragecapacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The total size for this long-term storage device.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
The capacity is in Kbytes. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device
|
||
|
installed."
|
||
|
::= { hrDiskStorageEntry 4 }
|
||
|
|
||
|
|
||
|
hrpartitionindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER(1..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A unique value for each partition on this long-
|
||
|
term storage device. The value for each long-term
|
||
|
storage device must remain constant at least from
|
||
|
one re-initialization of the agent to the next re-
|
||
|
initialization.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
Constant. The first and second index
|
||
|
indicates the hrDeviceIndex for this mass storage device.
|
||
|
The value of this object is the same as
|
||
|
the second index. The printer only supports one
|
||
|
partition per mass storage device. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device
|
||
|
installed."
|
||
|
::= { hrPartitionEntry 1 }
|
||
|
|
||
|
|
||
|
hrpartitionlabel OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..11))
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A textual description of this partition.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
The MS-DOS volume label. The volume
|
||
|
label is writable. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device installed.
|
||
|
This object is settable and returns the empty
|
||
|
string if the mass storage device has not been initialized. NOTE
|
||
|
the RamDisk will lose this value after a PowerCycle."
|
||
|
::= { hrPartitionEntry 2 }
|
||
|
|
||
|
|
||
|
hrpartitionid OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A descriptor which uniquely represents this
|
||
|
partition to the responsible operating system. On
|
||
|
some systems, this might take on a binary
|
||
|
representation.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
Constant. The value returned is the
|
||
|
ASCII string version of the hrDeviceIndex for
|
||
|
this mass storage device. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device
|
||
|
installed."
|
||
|
::= { hrPartitionEntry 3 }
|
||
|
|
||
|
|
||
|
hrpartitionsize OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The size of this partition.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
The capacity is in Kbytes. Returns the
|
||
|
same value as hrDiskStorageCapacity. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device
|
||
|
installed."
|
||
|
::= { hrPartitionEntry 4 }
|
||
|
|
||
|
|
||
|
hrpartitionfsindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The index of the file system mounted on this
|
||
|
partition. If no file system is mounted on this
|
||
|
partition, then this value shall be zero. Note
|
||
|
that multiple partitions may point to one file
|
||
|
system, denoting that that file system resides on
|
||
|
those partitions. Multiple file systems may not
|
||
|
reside on one partition.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
Indicates if the mass storage device has been
|
||
|
initialized. Applications determine if the storage device
|
||
|
has been initialized by getting this object. Returns zero
|
||
|
if the mass storage device is not
|
||
|
initialized, otherwise the value matches the
|
||
|
hrDeviceIndex value for this mass storage device.
|
||
|
The value indicates the
|
||
|
hrFileSystemTable index for the file system stored
|
||
|
on this partition. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device
|
||
|
installed."
|
||
|
::= { hrPartitionEntry 5 }
|
||
|
|
||
|
|
||
|
hrfsindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER(1..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A unique value for each file system local to this
|
||
|
host. The value for each file system must remain
|
||
|
constant at least from one re-initialization of
|
||
|
the agent to the next re-initialization.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
Constant. The index is assigned by the
|
||
|
person controlling the printer object definition.
|
||
|
Returns <noSuchName> status if
|
||
|
attempting to perform a Get on this OID with no mass storage device
|
||
|
installed or if the file system has not been
|
||
|
initialized."
|
||
|
::= { hrFSEntry 1 }
|
||
|
|
||
|
|
||
|
hrfsmountpoint OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The path name of the root of this file system.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
Constant. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device installed
|
||
|
or if the file system has not been initialized."
|
||
|
::= { hrFSEntry 2 }
|
||
|
|
||
|
|
||
|
hrfsremotemountpoint OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A description of the name and/or address of the
|
||
|
server that this file system is mounted from.
|
||
|
This may also include parameters such as the mount
|
||
|
point on the remote file system. If this is not a
|
||
|
remote file system, this string should have a
|
||
|
length of zero.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
Constant. This printer does not support
|
||
|
remote file system mounting. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device installed
|
||
|
or if the file system has not been initialized."
|
||
|
::= { hrFSEntry 3 }
|
||
|
|
||
|
|
||
|
hrfstype OBJECT-TYPE
|
||
|
SYNTAX OBJECT IDENTIFIER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object identifies the type of
|
||
|
this file system.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
Constant. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device installed
|
||
|
or if the file system has not been initialized."
|
||
|
::= { hrFSEntry 4 }
|
||
|
|
||
|
|
||
|
hrfsaccess OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eHreadWrite(1),
|
||
|
eHreadOnly(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An indication if this file system is logically
|
||
|
configured by the operating system to be readable
|
||
|
and writable or only readable. This does not
|
||
|
represent any local access-control policy, except
|
||
|
one that is applied to the file system as a whole.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
Returns the same value as
|
||
|
hrDiskStorageAccess. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device installed
|
||
|
or if the file system has not been initialized."
|
||
|
::= { hrFSEntry 5 }
|
||
|
|
||
|
|
||
|
hrfsbootable OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eHfalse(2)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A flag indicating whether this file system is
|
||
|
bootable.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
Constant. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device installed
|
||
|
or if the file system has not been initialized."
|
||
|
::= { hrFSEntry 6 }
|
||
|
|
||
|
|
||
|
hrfsstorageindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The index of the hrStorageEntry that represents
|
||
|
information about this file system. If there is
|
||
|
no such information available, then this value
|
||
|
shall be zero. The relevant storage entry will be
|
||
|
useful in tracking the percent usage of this file
|
||
|
system and diagnosing errors that may occur when
|
||
|
it runs out of space.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
Constant. The value indicates the
|
||
|
hrStorageTable index for this mass storage device. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to perform a Get on this OID with no mass storage device installed
|
||
|
or if the file system has not been initialized."
|
||
|
::= { hrFSEntry 7 }
|
||
|
|
||
|
|
||
|
hrfslastfullbackupdate OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The last date at which this complete file system
|
||
|
was copied to another storage device for backup.
|
||
|
This information is useful for ensuring that
|
||
|
backups are being performed regularly.
|
||
|
If this information is not known, then this
|
||
|
variable shall have the value corresponding to
|
||
|
January 1, year 0000, 00:00:00.0, which is encoded
|
||
|
as (hex)'00 00 01 01 00 00 00 00'.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
Constant.
|
||
|
The default value is the value defined
|
||
|
to represent an unknown time of January 1, year 0000,
|
||
|
00:00:00.0. Returns <noSuchName>
|
||
|
status if attempting to perform a Get on this OID
|
||
|
with no mass storage device installed or if the file system has not
|
||
|
been initialized."
|
||
|
::= { hrFSEntry 8 }
|
||
|
|
||
|
|
||
|
hrfslastpartialbackupdate OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The last date at which a portion of this file
|
||
|
system was copied to another storage device for
|
||
|
backup. This information is useful for ensuring
|
||
|
that backups are being performed regularly.
|
||
|
If this information is not known, then this
|
||
|
variable shall have the value corresponding to
|
||
|
January 1, year 0000, 00:00:00.0, which is encoded
|
||
|
as (hex)'00 00 01 01 00 00 00 00'.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
Constant.
|
||
|
The default value is the value defined
|
||
|
to represent an unknown time of January 1, year 0000,
|
||
|
00:00:00.0. Returns <noSuchName>
|
||
|
status if attempting to perform a Get on this OID
|
||
|
with no mass storage device installed or if the file system has not
|
||
|
been initialized."
|
||
|
::= { hrFSEntry 9 }
|
||
|
|
||
|
|
||
|
|
||
|
mio1-model-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns product information identifying the I/O card.
|
||
|
Example: XXXX"
|
||
|
::= { mio1 2 }
|
||
|
|
||
|
|
||
|
mio1-manufacturing-info OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns information describing the manufacture of the
|
||
|
I/O card installed in MIO/EIO slot 1. May include
|
||
|
serial number and firmware revision.
|
||
|
Additional information:
|
||
|
The format of the string returned is determined by
|
||
|
the manufacturer of the EIO device. There is no standard for content of the
|
||
|
string."
|
||
|
::= { mio1 3 }
|
||
|
|
||
|
|
||
|
mio1-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eDiskDrive(8),
|
||
|
eIOCard(12)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
MIO/EIO slot 1. See SIMM1-TYPE for an explanation of
|
||
|
the enumerations."
|
||
|
::= { mio1 4 }
|
||
|
|
||
|
|
||
|
mio2-model-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns product information identifying the I/O card.
|
||
|
Example: XXXX"
|
||
|
::= { mio2 2 }
|
||
|
|
||
|
|
||
|
mio2-manufacturing-info OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns information describing the manufacture of the
|
||
|
I/O card installed in MIO/EIO slot 2. May include
|
||
|
serial number and firmware revision.
|
||
|
Additional information:
|
||
|
The format of the string returned is determined by
|
||
|
the manufacturer of the EIO device. There is no standard for content of the
|
||
|
string."
|
||
|
::= { mio2 3 }
|
||
|
|
||
|
|
||
|
mio2-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eDiskDrive(8),
|
||
|
eIOCard(12)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
MIO/EIO slot 2. See SIMM1-TYPE for an explanation of
|
||
|
the enumerations."
|
||
|
::= { mio2 4 }
|
||
|
|
||
|
mio3-model-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns product information identifying the I/O card.
|
||
|
Example: XXXX"
|
||
|
::= { mio3 2 }
|
||
|
|
||
|
|
||
|
mio3-manufacturing-info OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns information describing the manufacture of the
|
||
|
I/O card installed in MIO/EIO interface 3. May include
|
||
|
serial number and firmware revision.
|
||
|
Additional information:
|
||
|
The format of the string returned is determined by
|
||
|
the manufacturer of the EIO device. There is no standard for content of the
|
||
|
string."
|
||
|
::= { mio3 3 }
|
||
|
|
||
|
|
||
|
mio3-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eDiskDrive(8),
|
||
|
eIOCard(12)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
MIO/EIO interface 3. See SIMM1-TYPE for an explanation
|
||
|
of the enumerations."
|
||
|
::= { mio3 4 }
|
||
|
|
||
|
job-info-change-id OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(16))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the current value of an object in the job-info
|
||
|
sub-tree whose value has changed. Define the object
|
||
|
identifier for the object whose value has changed as
|
||
|
job-info.required-field.optional-field.job-id. job-info
|
||
|
represents the OID prefix of all objects in the job-info
|
||
|
sub-tree. Required-field represents the OID field value
|
||
|
that follows the job-info prefix. Since some objects in
|
||
|
the job-info sub-tree have two OID fields between the
|
||
|
job-info prefix and the job-id, the optional-field
|
||
|
represents the OID field between the required-field and
|
||
|
the job-id field, if present. Using this definition,
|
||
|
the format for the JOB-INFO-CHANGE-ID binary value can
|
||
|
be described as follows:
|
||
|
Bytes 0-3 : required-field
|
||
|
Bytes 4-7 : optional-field, or all zeros if there
|
||
|
is no optional field
|
||
|
Bytes 8-11: Job ID.
|
||
|
Bytes 12-n : The value of the object job-info.
|
||
|
required-field.optional-field.job-id.
|
||
|
All multi-byte values stored in Motorola (big-endian)
|
||
|
format, where the most significant byte occurs first.
|
||
|
Additional information:
|
||
|
LaserJet 4050 Series will use this object to report
|
||
|
changes to the job-info-pages-printed and job-info-state
|
||
|
objects. The required-field (bytes 0 through 3) will
|
||
|
designate whether the change to be reported involves the
|
||
|
pages printed (13) or job state (15). The optional-field
|
||
|
(bytes 4 through 7) will always be zeroes. The value-field
|
||
|
(bytes 12 through 15) will contain the new value for pages
|
||
|
printed or job state cast to a 32-bit integer."
|
||
|
::= { settings-job 3 }
|
||
|
|
||
|
|
||
|
hold-job-timeout OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The time, in minutes, that the printer will wait before
|
||
|
automatically deleting a held job. This allows the
|
||
|
printer to automatically clean up jobs that have been
|
||
|
forgotten (held but never released).
|
||
|
Additional information:
|
||
|
This only applies to temporary held jobs, i.e., HOLD=ON or
|
||
|
PROOF. This is a global timer that only affects the jobs
|
||
|
that are sent after it is set.
|
||
|
A value of 0 means never delete the jobs.
|
||
|
Setting it to an unsupported value causes
|
||
|
the printer to substitute a value (listed
|
||
|
below) and to return <noError>
|
||
|
status.
|
||
|
LaserJet 4050 Series supports values of 0, 60, 240, 1440, and 10080
|
||
|
The values are as follows:
|
||
|
<=0 snap to 0 (disabled)
|
||
|
>=1 and <=150 snap to 60 (60 minutes)
|
||
|
>=151 and <=840 snap to 240 (4 hours)
|
||
|
>=841 and <=2880 snap to 1440 (1 day)
|
||
|
>=2881 snap to 10080 (1 week)"
|
||
|
::= { settings-job 10 }
|
||
|
|
||
|
|
||
|
current-job-parsing-id OBJECT-TYPE
|
||
|
SYNTAX INTEGER(-1..32767)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains the printer assigned job identification for the
|
||
|
job currently being processed by the processing PDL sub-
|
||
|
system. The job ID is a monotonically increasing
|
||
|
number. The job ID may be reset to zero at power-up and
|
||
|
may roll over to zero after reaching some maximum
|
||
|
value.
|
||
|
Additional information:
|
||
|
A value of -1 is returned when the printer
|
||
|
is not parsing a job.
|
||
|
|
||
|
When data for a new job is detected, this object is
|
||
|
updated (the job may or may not turn out to be a Null
|
||
|
Job); however, the trap does not occur until the printer
|
||
|
determines that it is not a Null Job. (A job is considered
|
||
|
to be a 'null job' if it has no name or job attribute,
|
||
|
causes no pages to be printed, and consumes MIN-JOB-SIZE
|
||
|
(9) or fewer bytes.) A trapped value will differ from
|
||
|
the previous value by one or more.
|
||
|
|
||
|
Some job-info- objects are created when the first data
|
||
|
bytes are received. If the printer determines that the
|
||
|
job is a Null Job, the job-info- objects related to the
|
||
|
Null Job are deleted. LaserJet 4050 Series retains the job-info-
|
||
|
objects for the MAX-JOBS-IN-LIST (12) most recent jobs
|
||
|
that are not Null Jobs.
|
||
|
|
||
|
The first job received after power-up will have job ID 1,
|
||
|
and the job ID will increment to 32767 before rolling
|
||
|
to zero. To distinguish whether a power cycle or a
|
||
|
rollover causes a reduction in the job ID value, the
|
||
|
object prtGeneralConfigChanges can be watched and if it
|
||
|
increments at the same time as the drop is observed in
|
||
|
the value of CURRENT-JOB-PARSING-ID, then a power cycle
|
||
|
is the most likely cause."
|
||
|
::= { job-being-parsed 1 }
|
||
|
|
||
|
|
||
|
job-info-name1 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains the first part of this print job's name. The
|
||
|
last OID field for this dynamic object contains the job
|
||
|
ID.
|
||
|
Additional information:
|
||
|
The job name is the string specified by the
|
||
|
NAME= parameter of the @PJL JOB command which allows a
|
||
|
maximum of 80 characters. The first 40 characters are
|
||
|
in this object and the second 40 are in job-info-name2.
|
||
|
The symbol set is Roman-8.
|
||
|
|
||
|
When jobs are nested, the value assigned to this object
|
||
|
is the name provided by the most recent @PJL JOB NAME=
|
||
|
command. If no name is provided, a null string is
|
||
|
returned."
|
||
|
::= { job-info 1 }
|
||
|
|
||
|
|
||
|
job-info-name2 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Contains the second part of this print job's name. The
|
||
|
last OID field for this dynamic object contains the job
|
||
|
ID.
|
||
|
Additional information:
|
||
|
See job-info-name1."
|
||
|
::= { job-info 2 }
|
||
|
|
||
|
|
||
|
job-info-stage OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates what printer sub-systems are currently
|
||
|
processing this print job. The last OID field for this
|
||
|
dynamic object contains the job ID.
|
||
|
cSourceSubsystem - some of the job is in the printer
|
||
|
I/O subsystem.
|
||
|
cProcessingSubsystem - some of the job is in the
|
||
|
printer imaging processing subsystem.
|
||
|
cDestinationSubsystem - some of the job is being
|
||
|
printed.
|
||
|
Additional information:
|
||
|
For LaserJet 4050 Series, cSourceSubsystem and
|
||
|
cProcessingSubsystem will always be set and cleared
|
||
|
together. They are set when the beginning of the
|
||
|
job is detected, and they are cleared when the end
|
||
|
of the job is parsed.
|
||
|
|
||
|
A non-printing job will never set
|
||
|
cDestinationSubsystem.
|
||
|
|
||
|
When a page is ready to be printed (the intermediate has
|
||
|
been built and the page is `closed' by the personality),
|
||
|
cDestinationSubsystem will be set even if a page of a
|
||
|
previous job is currently being printed.
|
||
|
cDestinationSubsystem remains set until the last page of
|
||
|
the job has finished printing.
|
||
|
|
||
|
If a page requires extensive processing and allows all
|
||
|
the previous pages of a job to complete printing,
|
||
|
cDestinationSubsystem will remain set until the last
|
||
|
page of the job has finished printing."
|
||
|
::= { job-info 10 }
|
||
|
|
||
|
|
||
|
job-info-io-source OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates which I/O source, the print job was received
|
||
|
over. The value maps to port numbering scheme supported
|
||
|
in the DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree."
|
||
|
::= { job-info 11 }
|
||
|
|
||
|
|
||
|
job-info-pages-processed OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates the number of pages processed by the
|
||
|
processing subsystem. If neither the cSourceSubsystem
|
||
|
or the cProcessingSubsystem items are in the associated
|
||
|
JOB-INFO-STAGE object, then this object contains the
|
||
|
total number of pages processed for this job. The last
|
||
|
OID field for this dynamic object contains the job ID.
|
||
|
Additional information:
|
||
|
This object is incremented by one when a
|
||
|
page is processed (`closed' by the personality), regardless
|
||
|
of the number of pages that are printed as a result of the
|
||
|
single page processed. In other words, it does not matter
|
||
|
how many identical copies of a page are printed or no pages
|
||
|
may be printed if operating in silent run mode, this count
|
||
|
is incremented exactly once.
|
||
|
|
||
|
A page is considered processed when all of the input
|
||
|
data has been processed for a page (that is, when the
|
||
|
intermediate has been produced, and the personality has
|
||
|
`closed' the page. At this time, the image of the page is
|
||
|
not necessarily completely formed.)"
|
||
|
::= { job-info 12 }
|
||
|
|
||
|
|
||
|
job-info-pages-printed OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates the number of pages printed by the destination
|
||
|
subsystem. If non of the cSourceSubsystem,
|
||
|
cProcessingSubsystem or cDestinationSubsystem items are
|
||
|
in the associated JOB-INFO-STAGE object, then this
|
||
|
object contains the total number of pages printed for
|
||
|
this job. This value may increase by two each time for
|
||
|
duplex jobs. The last OID field for this dynamic object
|
||
|
contains the job ID.
|
||
|
Additional information:
|
||
|
If multiple copies of a page are printed,
|
||
|
each copy is counted individually."
|
||
|
::= { job-info 13 }
|
||
|
|
||
|
|
||
|
job-info-size OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates the number of bytes of data processed by the
|
||
|
processing subsystem. If neither of the
|
||
|
cSourceSubsystem or cProcessingSubsystem items are in
|
||
|
the associated JOB-INFO-STAGE object, then this object
|
||
|
contains the size of this job, in bytes. The last OID
|
||
|
field for this dynamic object contains the job ID.
|
||
|
Additional information:
|
||
|
This count may be incremented by values
|
||
|
other than one as blocks of data are processed; blocks
|
||
|
of data (which may be as large as 2K bytes) will be
|
||
|
processed in a varying amount of time.
|
||
|
|
||
|
During the processing of a job and even when a job completes,
|
||
|
an exact count of the number of I/O bytes processed by the
|
||
|
job is not necessarily to be expected."
|
||
|
::= { job-info 14 }
|
||
|
|
||
|
|
||
|
job-info-state OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eAborted(3),
|
||
|
eWaitingForResources(4),
|
||
|
ePrinted(5),
|
||
|
eTerminating(7),
|
||
|
eCancelled(10),
|
||
|
eProcessing(11)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates the state of the job. The last OID field for
|
||
|
this dynamic object contains the job ID.
|
||
|
eAborted - the print job was aborted.
|
||
|
eWaitingForResources - the print job requires
|
||
|
resources that are not currently available. Example
|
||
|
resources that can cause the job to wait include the
|
||
|
print engine or PDL processor being unavailable. The
|
||
|
print engine could be unavailable due to paper out,
|
||
|
paper jam, staple out, stapler jam, marking agent low,
|
||
|
output bin full, etc. The PDL processor could be
|
||
|
unavailable due to an off-line condition. Each printer
|
||
|
specific object specification should state which
|
||
|
conditions cause a job to be waiting for resources and
|
||
|
also state which objects can be retrieved by an
|
||
|
application to determine the exact cause of a resource
|
||
|
being unavailable.
|
||
|
ePrinted - the job has printed. The related JOB-INFO-
|
||
|
OUTCOME object indicates if any problems were
|
||
|
encountered while the job was processed.
|
||
|
eRetained - the job can be reprinted.
|
||
|
eTerminating - the job was aborted or cancelled and is
|
||
|
currently is terminating.
|
||
|
eInterrupted - the job has been interrupted. The job
|
||
|
can be continued.
|
||
|
ePaused - the job has been paused. The job can be
|
||
|
continuted.
|
||
|
eCancelled - the job has been cancelled.
|
||
|
eProcessing - the job is currently being printed
|
||
|
normally."
|
||
|
::= { job-info 15 }
|
||
|
|
||
|
|
||
|
job-info-outcome OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOk(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if any warning or error conditions were
|
||
|
encountered while processing the assoicated job. The
|
||
|
last OID field for this dynamic object contains the job
|
||
|
ID.
|
||
|
Additional information:
|
||
|
In LaserJet 4050 Series, warnings and errors are not recorded
|
||
|
in this object. Although no meaningful information can be
|
||
|
obtained from this object, it is kept around for the
|
||
|
compatibility needs of existing software."
|
||
|
::= { job-info 19 }
|
||
|
|
||
|
|
||
|
job-info-attr-1 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. Attribute objects are saved
|
||
|
sequentially, starting with 1, after the start of a job.
|
||
|
If more attributes are set than there are objects to
|
||
|
store them, the excess JOBATTR values are ignored. If
|
||
|
the corresponding SET JOBATTR= command has not been
|
||
|
received when a get is done for this object, a status of
|
||
|
<noSuchName> will be returned."
|
||
|
::= { job-info-attribute 1 }
|
||
|
|
||
|
|
||
|
job-info-attr-2 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 2 }
|
||
|
|
||
|
|
||
|
job-info-attr-3 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 3 }
|
||
|
|
||
|
|
||
|
job-info-attr-4 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 4 }
|
||
|
|
||
|
|
||
|
job-info-attr-5 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 5 }
|
||
|
|
||
|
|
||
|
job-info-attr-6 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 6 }
|
||
|
|
||
|
|
||
|
job-info-attr-7 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 7 }
|
||
|
|
||
|
|
||
|
job-info-attr-8 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 8 }
|
||
|
|
||
|
|
||
|
job-info-attr-9 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 9 }
|
||
|
|
||
|
|
||
|
job-info-attr-10 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 10 }
|
||
|
|
||
|
|
||
|
job-info-attr-11 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 11 }
|
||
|
|
||
|
|
||
|
job-info-attr-12 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 12 }
|
||
|
|
||
|
|
||
|
job-info-attr-13 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 13 }
|
||
|
|
||
|
|
||
|
job-info-attr-14 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 14 }
|
||
|
|
||
|
|
||
|
job-info-attr-15 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 15 }
|
||
|
|
||
|
|
||
|
job-info-attr-16 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 16 }
|
||
|
|
||
|
job-info-attr-17 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 17 }
|
||
|
|
||
|
|
||
|
job-info-attr-18 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 18 }
|
||
|
|
||
|
|
||
|
job-info-attr-19 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 19 }
|
||
|
|
||
|
|
||
|
job-info-attr-20 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 20 }
|
||
|
|
||
|
|
||
|
job-info-attr-21 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 21 }
|
||
|
|
||
|
|
||
|
job-info-attr-22 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 22 }
|
||
|
|
||
|
|
||
|
job-info-attr-23 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 23 }
|
||
|
|
||
|
|
||
|
job-info-attr-24 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 24 }
|
||
|
|
||
|
|
||
|
job-info-attr-25 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 25 }
|
||
|
|
||
|
|
||
|
job-info-attr-26 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 26 }
|
||
|
|
||
|
|
||
|
job-info-attr-27 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 27 }
|
||
|
|
||
|
|
||
|
job-info-attr-28 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 28 }
|
||
|
|
||
|
|
||
|
job-info-attr-29 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 29 }
|
||
|
|
||
|
|
||
|
job-info-attr-30 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 30 }
|
||
|
|
||
|
|
||
|
job-info-attr-31 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 31 }
|
||
|
|
||
|
|
||
|
job-info-attr-32 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..80))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the value that was set in PJL via the SET
|
||
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
||
|
::= { job-info-attribute 32 }
|
||
|
|
||
|
|
||
|
job-info-requested-originals OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of requested collated copies. The value was
|
||
|
supplied with the job via PJL QTY variable, the
|
||
|
PostScript Collate and NumCopies entries in the page
|
||
|
device dictionary, or via some other mechansim."
|
||
|
::= { job-info 24 }
|
||
|
|
||
|
|
||
|
job-info-page-count-current-original OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The page number being printed within the current copy of
|
||
|
a collated multi-copy job. This value changes when the
|
||
|
job-info-pages-printed changes. The job-info-pages-
|
||
|
printed indicates the total number of pages printed in
|
||
|
the job, while this object indicates the number of pages
|
||
|
printed for this copy of a collated multi-copy job.
|
||
|
Additional information:
|
||
|
The number of pages in the current copy of a collated
|
||
|
multi-copy job which have been completely printed and
|
||
|
safely delivered to the output bin."
|
||
|
::= { job-info 25 }
|
||
|
|
||
|
|
||
|
job-info-pages-in-original OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of pages in a single copy of a collated multi-
|
||
|
copy job."
|
||
|
::= { job-info 26 }
|
||
|
|
||
|
|
||
|
job-info-printed-originals OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of collated copies completely printed and
|
||
|
delivered to the output bin at time of query."
|
||
|
::= { job-info 27 }
|
||
|
|
||
|
not-ready-processing-pdl OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if the PDL sub-system in the device is not
|
||
|
ready. If there are no items in the collection (i.e. no
|
||
|
bits are set), then the PDL sub-system is ready. If
|
||
|
there is an item present, then the item indicates what
|
||
|
is causing the PDL sub-system to be not ready. cOffLine
|
||
|
indicates the PDL processing sub-system is off line.
|
||
|
cPrintDataMemoryOverflow indicates the print job was
|
||
|
sufficiently complex to use up all memory available for
|
||
|
processing print job data. cSoftResourceMemoryOverflow
|
||
|
indicates the print job contained soft resources (fonts,
|
||
|
macros, etc.) that over flowed the available memory."
|
||
|
::= { status-pdl 1 }
|
||
|
|
||
|
form-feed-needed OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eFalse(1),
|
||
|
eTrue(2)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if the PDL processing sub-system has made
|
||
|
marks on the current page and the source subsystem has
|
||
|
been idle for a device specific amount of time.
|
||
|
Additional information:
|
||
|
LaserJet 4050 Series will set this object to eTrue when it
|
||
|
has made marks on the current page, the IO-TIMEOUT has
|
||
|
expired while PCL was running in `backward-compatibility
|
||
|
mode' (which is caused by jobs consisting purely of PCL
|
||
|
data with no prepended PJL commands), and no data is pending
|
||
|
on another I/O. Once it is set to eTrue, more data on the
|
||
|
same I/O will cause this object to be set to eFalse, until
|
||
|
the above conditions are met again."
|
||
|
::= { status-pdl 2 }
|
||
|
|
||
|
|
||
|
jetsend-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOff(1),
|
||
|
eOn(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Enables or disables the JetSend processing sub-system.
|
||
|
Additional information:
|
||
|
Enables or disables the JetSend processing subsystem.
|
||
|
The valid values are eOff and eOn. (Specifying an invalid mode
|
||
|
causes an <badValue> error to be returned.).
|
||
|
This object will be enabled in IR devices even if is does not
|
||
|
detect an EIO card."
|
||
|
::= { settings-jetsend 1 }
|
||
|
|
||
|
|
||
|
jetsend-contact-password OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(16))
|
||
|
ACCESS write-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A C structure containing the following fields:
|
||
|
typedef struct {
|
||
|
ubyte old-password[8];
|
||
|
ubyte new-password[8];/
|
||
|
} jetsend-change-contact-password-t;
|
||
|
where ubyte is an unsigned byte (0-255).
|
||
|
Additional information:
|
||
|
Controls access to the JetSend processing subsystem.
|
||
|
Password absence/presence determines whether the device will allow
|
||
|
a session to be established. The following C data structure
|
||
|
contains the relevant fields (described in subsequent paragraphs):
|
||
|
|
||
|
typedef struct {
|
||
|
unsigned char old-password[8];
|
||
|
unsigned char new-password[8];
|
||
|
}
|
||
|
|
||
|
Whenever the password is disabled (i.e., is zero-filled for its
|
||
|
entire length), the device is indicating its willingness to allow
|
||
|
session establishment. Whenever the password is enabled (i.e., has
|
||
|
one or more non-zero-filled values), the device is controlling
|
||
|
session establishment -- all in-progress JetSend sessions must
|
||
|
supply a matching password or the device will reject the in-progress
|
||
|
session.
|
||
|
|
||
|
To disable the password, specify the matching password via the
|
||
|
'old-password' field and zero-fill the 'new-password' field.
|
||
|
To enable the password for the first time, zero-fill the
|
||
|
'old-password' field and specify the new password via the
|
||
|
'new-password' field (the new password should not be
|
||
|
zero-filled; otherwise, the password will remain disabled).
|
||
|
To enable or change the password thereafter, specify the
|
||
|
matching password via the 'old-password' field and specify
|
||
|
the new password via the 'new-password' field (the new
|
||
|
desired password should not be zero-filled; otherwise,
|
||
|
the password will be disabled). To determine if the password
|
||
|
is enabled, zero-fill both the 'old-password' and 'new-password'
|
||
|
fields. If an error occurs, the password is enabled; otherwise,
|
||
|
the password is disabled.
|
||
|
|
||
|
(Specifying either an 'old-password' or 'new-password'
|
||
|
fields greater than eight (8) bytes causes the error
|
||
|
<badValue> to be returned.)
|
||
|
|
||
|
This object will be enabled in IR devices even if is does not
|
||
|
detect an EIO card."
|
||
|
::= { settings-jetsend-contact 1 }
|
||
|
|
||
|
|
||
|
jetsend-contact-ip-address-security OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(16))
|
||
|
ACCESS write-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A C structure containing the following fields:
|
||
|
typedef struct {
|
||
|
ubyte reserved[3];
|
||
|
ubyte command; /* command: 0 to 1 */
|
||
|
ubyte password[8];
|
||
|
ubyte IPAddress[4];
|
||
|
} jetsend-contact-ip-address-security-t;
|
||
|
where ubyte is an unsigned byte (0-255). The defined
|
||
|
values defined for command are:
|
||
|
|
||
|
When command is 0:
|
||
|
IPAddress is 0: device is locked, no one can contact
|
||
|
it
|
||
|
IPAddress is > 0: only that address is allowed to
|
||
|
contact the device
|
||
|
|
||
|
When command is 1:
|
||
|
IPAddress is 0: any device can contact it
|
||
|
IPAddress is > 0: any device matching this mask can
|
||
|
contact it. If the result of logically anding the mask
|
||
|
value supplied in the IPAddress field with the sending
|
||
|
device's IP address matches the result of logically
|
||
|
anding the mask value supplied in the IPAddress field
|
||
|
with this device's IP address, then JetSend will allow
|
||
|
the session to be established.
|
||
|
Additional information:
|
||
|
Controls the device or class of device(s) which may
|
||
|
communicate with the JetSend processing subsystem. The following C
|
||
|
data structure contains the relevant fields (described in subsequent
|
||
|
paragraphs):
|
||
|
|
||
|
typedef struct {
|
||
|
unsigned char reserved[3];
|
||
|
unsigned char command;
|
||
|
unsigned char password[8];
|
||
|
unsigned char IPAddress[4];
|
||
|
}
|
||
|
|
||
|
The 'reserved' field is not used and should remain zero-filled.
|
||
|
The 'command' field interpretation differs based on its value:
|
||
|
|
||
|
0 = Accept session(s) only from the specific device whose
|
||
|
IP address matches the specified IP address; all other
|
||
|
session request(s) from non-matching device(s) are rejected.
|
||
|
1 = Accept session(s) only from the specific device(s) whose
|
||
|
IP address(es) conform to the mask specified in the 'IPAddress'
|
||
|
field; all other session request(s) from device(s) with
|
||
|
non-matching submask(s) are rejected. (If the result of
|
||
|
logically AND'ing the mask value supplied in the 'IPAddress'
|
||
|
field with the sending device's IP address matches the result
|
||
|
of logically AND'ing the mask value supplied in the 'IPAddress'
|
||
|
field with this device's IP address, then JetSend will allow
|
||
|
session establishment.
|
||
|
|
||
|
Password absence/presence determines whether the device will allow
|
||
|
the caller to alter the IP address security. If the password is
|
||
|
disabled, the caller may set the 'command' and 'IPAddress' fields
|
||
|
directly. If the password is enabled, the caller may (re-)set the
|
||
|
'command' and 'IPAddress' fields only after specifying the matching
|
||
|
'password' field. (Refer to the aforementioned 'JETSEND-CONTACT-PASSWORD'
|
||
|
object ID.)
|
||
|
|
||
|
(Specifying either an invalid 'command' field value or a 'password'
|
||
|
field greater than eight (8) bytes or an 'IPAddress' field greater
|
||
|
than four (4) bytes causes the error <badValue>
|
||
|
to be returned.)
|
||
|
|
||
|
This object will be enabled in IR devices even if is does not
|
||
|
detect an EIO card."
|
||
|
::= { settings-jetsend-contact 2 }
|
||
|
|
||
|
|
||
|
host-application-available-memory OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the amount of memory, in bytes, that the device
|
||
|
has available for job-related processing or resources.
|
||
|
Also known as driver work space (DWS) memory."
|
||
|
::= { status-system 59 }
|
||
|
|
||
|
|
||
|
held-job-user-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..40))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"User name that is obtained by the driver through some
|
||
|
internal method or from user input.
|
||
|
Additional information:
|
||
|
The following is a general description for all the JOB-MANAGEMENT
|
||
|
objects described below. These object describe the attributes of the
|
||
|
dynamic list containing all the stored jobs on the disk available for
|
||
|
printing or deleting via the job-management feature. The jobs on this
|
||
|
list are not deleted from the disk unless explicitly specified by the
|
||
|
user. A print job may be specified for retention by PJL commands in the
|
||
|
data stream.
|
||
|
|
||
|
Following is a list of the PJL commands (i.e. these comments describe
|
||
|
the PJL implementation and in some cases do not reflect the PML
|
||
|
implementation.):
|
||
|
|
||
|
@PJL SET HOLD=OFF|ON|PROOF|STORE|PRINT
|
||
|
|
||
|
GENERAL DESCRIPTION:
|
||
|
|
||
|
This variable specifies the retention classification of the job. The
|
||
|
values indicate whether the job is printed immediately and/or stored.
|
||
|
|
||
|
OFF: The job is printed but not retained on disk after printing. This
|
||
|
is the default value.
|
||
|
|
||
|
ON: This setting may be thought of as free proof-and-hold. The
|
||
|
requested number of copies will be printed and the job will be
|
||
|
temporarily stored on disk. The job will then be available for printing
|
||
|
additional copies through the control panel and through PML. There will
|
||
|
be a limit to the number of these temporary jobs that may be stored, and
|
||
|
when the limit is exceeded the oldest job will be removed from the disk.
|
||
|
|
||
|
PROOF: One copy of the job is printed and remaining copies are stored
|
||
|
on disk. The job is then available to select for printing via the
|
||
|
control panel menus or PML. The job will be deleted from the disk when
|
||
|
the disk space is needed for another proof and hold job but only after
|
||
|
the additional copies have been printed. It will also be deleted when
|
||
|
the user sends down another proof and hold job with the same job name,
|
||
|
or the user explicitly deletes the job.
|
||
|
|
||
|
STORE: The job is not printed immediately but is retained on disk. The
|
||
|
job is available to select for printing via the control panel
|
||
|
|
||
|
DEFAULT VALUE: OFF
|
||
|
|
||
|
The value will be stored in RAM only, not in NVRAM.
|
||
|
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
|
||
|
The variable will appear in the PJL INFO VARIABLES list.
|
||
|
|
||
|
@PJL SET USERNAME=<80 bytes>
|
||
|
|
||
|
GENERAL DESCRIPTION:
|
||
|
|
||
|
Eighty-character user name that is obtained by the driver through some
|
||
|
internal method or from user input. If the job stream does not contain
|
||
|
a USERNAME the default value will be NO USER NAME. The driver is
|
||
|
responsible for determining the size of the printers control panel and
|
||
|
sending a string of appropriate length.
|
||
|
|
||
|
DEFAULT VALUE: NO USER NAME
|
||
|
|
||
|
The value will be stored in RAM only, not in NVRAM.
|
||
|
The legal PJL commands are SET and, INQUIRE. DEFAULT is not allowed.
|
||
|
The variable will appear in the PJL INFO VARIABLES list.
|
||
|
|
||
|
@PJL SET JOBNAME=<80 bytes>
|
||
|
|
||
|
GENERAL DESCRIPTION:
|
||
|
|
||
|
Eighty-character job name that may be generated by the driver or
|
||
|
obtained from user input. This value may be used in conjunction with
|
||
|
the USERNAME to select a job from the front panel. If the job stream
|
||
|
does not contain a JOBNAME, the printer will assume no job name; each
|
||
|
subsequent job that is sent down by the same user would replace the
|
||
|
users last job on disk. The driver is responsible for determining the
|
||
|
size of the printers control panel and sending a string of appropriate
|
||
|
length.
|
||
|
|
||
|
NOTE: The limit of 80 bytes is a PJL limit. The limit for PML will
|
||
|
be 40 bytes.
|
||
|
|
||
|
DEFAULT VALUE: NULL STRING
|
||
|
|
||
|
The value will be stored in RAM only, not in NVRAM.
|
||
|
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
|
||
|
The variable will appear in the PJL INFO VARIABLES list.
|
||
|
|
||
|
@PJL SET HOLDTYPE=PUBLIC|PRIVATE
|
||
|
|
||
|
GENERAL DESCRIPTION:
|
||
|
|
||
|
This variable specifies the privacy level of the job.
|
||
|
|
||
|
PUBLIC: The job does not require a PIN in order to be released for
|
||
|
printing. This is the default value.
|
||
|
|
||
|
PRIVATE: The job requires a PIN in order to be released for printing.
|
||
|
The PIN is specified by the HOLDKEY variable. If the
|
||
|
|
||
|
HOLDTYPE is set to PRIVATE, a HOLDKEY value must be specified. If no
|
||
|
HOLDKEY is specified, the job will be considered PUBLIC.
|
||
|
|
||
|
DEFAULT VALUE: PUBLIC
|
||
|
|
||
|
The value will be stored in RAM only, not in NVRAM.
|
||
|
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
|
||
|
The variable will appear in the PJL INFO VARIABLES list.
|
||
|
|
||
|
@PJL SET HOLDKEY=4 digits, 0000...9999
|
||
|
|
||
|
GENERAL DESCRIPTION:
|
||
|
|
||
|
A 4-digit string, each digit 0-9, that is specified in the job stream
|
||
|
and then required to be entered in order to release the job for
|
||
|
printing. If a HOLDTYPE is PRIVATE, a HOLDKEY value must be specified.
|
||
|
If no HOLDKEY value is specified, a job will be considered PUBLIC.
|
||
|
|
||
|
DEFAULT VALUE: NULL STRING
|
||
|
|
||
|
The value will be stored in RAM only, not in NVRAM.
|
||
|
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
|
||
|
The variable will appear in the PJL INFO VARIABLES list.
|
||
|
|
||
|
|
||
|
The format for the OID is as follows:
|
||
|
|
||
|
3.4.1.6.x.y
|
||
|
<-----> | |
|
||
|
| | \
|
||
|
/ | job-id in the system
|
||
|
/ \
|
||
|
PML-JOB-MGNT-ROOT-OID \
|
||
|
job attribute 1..6
|
||
|
|
||
|
x values are 1..6:
|
||
|
|
||
|
1) user-name: user name that is obtained by the driver through some
|
||
|
internal method or from user input.
|
||
|
|
||
|
2) job-name: job name may be generated by the driver or obtained from
|
||
|
user input.
|
||
|
|
||
|
3) hold: indicates the retention classification of the job. The values
|
||
|
indicate whether the job is printed immediately and/or stored. There
|
||
|
are 4 options:
|
||
|
OFF: The job is printed but not retained on the disk.
|
||
|
ON: The job is printed and stored temporarily on the disk.
|
||
|
STORE: The job is not printed but stored on the disk.
|
||
|
PROOF: One copy of the job is printed and the remaining copies are
|
||
|
stored on the disk.
|
||
|
|
||
|
4) holdtype: The variable specifies the security level of the job.
|
||
|
PUBLIC: The job does not require a PIN in order to release the job for
|
||
|
printing.
|
||
|
PRIVATE: The job requires a PIN in order to be released for printing.
|
||
|
|
||
|
5) quantity: number of copies to print. Valid values are 0..999.
|
||
|
|
||
|
6) pin: A 4 digit string, each digit is 0-9, that is specified in the
|
||
|
job stream and then required to be entered in order to release the job
|
||
|
for printing.
|
||
|
|
||
|
y : an unsigned 15 bit number which uniquely identifies the job. The job
|
||
|
id for the job remains the same for the job until it is deleted from the
|
||
|
held jobs list.
|
||
|
|
||
|
|
||
|
For example, the OID below is asking for the user name of the
|
||
|
job whose id is 3. The application would issue:
|
||
|
|
||
|
OID
|
||
|
get 3.4.1.6.1.3
|
||
|
|
||
|
For example, the <getnext> OID values sequence is as follows:
|
||
|
|
||
|
OID returned OID
|
||
|
getnext 3.4.1.6 3.4.1.6.1.1
|
||
|
getnext 3.4.1.6.1.1 3.4.1.6.1.2
|
||
|
getnext 3.4.1.6.2.1 3.4.1.6.2.2
|
||
|
...
|
||
|
getnext 3.4.1.6.1.6 3.4.1.6.1.7
|
||
|
getnext 3.4.1.6.2.1 3.4.1.6.2.2
|
||
|
getnext 3.4.1.6.5.2828 3.4.1.6.6.1
|
||
|
|
||
|
NOTE: for example above, job id 2828 is the last job in the list of
|
||
|
held jobs.
|
||
|
...
|
||
|
|
||
|
Also supported is <getnext> on the job attributes:
|
||
|
OID returned OID
|
||
|
getnext 3.4.1.6.1 3.4.1.6.1.1
|
||
|
getnext 3.4.1.6.6 3.4.1.6.6.1"
|
||
|
::= { held-job-info 1 }
|
||
|
|
||
|
|
||
|
held-job-job-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..40))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The job name may be generated by the driver or obtained
|
||
|
from user input."
|
||
|
::= { held-job-info 2 }
|
||
|
|
||
|
|
||
|
held-job-retention OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eHoldOff(1),
|
||
|
eHoldOn(2),
|
||
|
eHoldStore(3),
|
||
|
eHoldProof(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates the retention classification of the job. The
|
||
|
values indicate whether the job is printed immediately
|
||
|
and/or stored. There are 4 options:
|
||
|
OFF: The job is printed but not retained on the disk.
|
||
|
ON: The job is printed and stored temporarily on the disk.
|
||
|
PROOF: One copy of the job is printed and the remaining copies are stored on the disk.
|
||
|
STORE: The job is not printed but stored on the disk."
|
||
|
::= { held-job-info 3 }
|
||
|
|
||
|
|
||
|
held-job-security OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eHoldTypePublic(1),
|
||
|
eHoldTypePrivate(2)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The variable specifies the security level of the job.
|
||
|
PUBLIC: The job does not require a PIN in order to release the job for printing.
|
||
|
PRIVATE: The job requires a PIN in order to be released for printing."
|
||
|
::= { held-job-info 4 }
|
||
|
|
||
|
|
||
|
held-job-quantity OBJECT-TYPE
|
||
|
SYNTAX INTEGER(1..999)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Number of copies to print."
|
||
|
::= { held-job-info 5 }
|
||
|
|
||
|
|
||
|
held-job-pin OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..4))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A string that is specified in the job stream and then
|
||
|
required to be entered in order to release the job for
|
||
|
printing. PIN stands for Personal Identification
|
||
|
Number.
|
||
|
Additional information:
|
||
|
Must be a 4 digit string, each digit must be 0..9 or a null string
|
||
|
if there is no pin."
|
||
|
::= { held-job-info 6 }
|
||
|
|
||
|
|
||
|
held-job-print OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(8))
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Instructs the printer to schedule the specified held job
|
||
|
for printing with the specified number of copies. The
|
||
|
job-id is used to identify which job to print. A held
|
||
|
job can also be printed from the control panel.
|
||
|
Additional information:
|
||
|
Bytes 0-3 is the job id of the job to print.
|
||
|
Bytes 4-7 is the number of copies to print."
|
||
|
::= { held-job-control 1 }
|
||
|
|
||
|
|
||
|
held-job-delete OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..32768)
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Instructs the printer to delete the specified held job
|
||
|
from the list. The job-id is used to identify which job
|
||
|
to delete. A held job can also be deleted from the
|
||
|
control panel.
|
||
|
Additional information:
|
||
|
"
|
||
|
::= { held-job-control 2 }
|
||
|
|
||
|
|
||
|
held-job-set-queue-size OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..50)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Sets the maximum number of jobs which can be stored in
|
||
|
the held job list.
|
||
|
Additional information:
|
||
|
Sets the size of the temporary job lists queue."
|
||
|
::= { held-job-control 3 }
|
||
|
|
||
|
|
||
|
held-job-enable OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eDisabled(1),
|
||
|
eEnabled(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Enables or disables Job Retention (Job Hold). The valid
|
||
|
values are eDisabled and eEnabled. (Specifying an
|
||
|
invalid mode causes an <badValue>
|
||
|
error to be returned.) When eDisabled is specified all
|
||
|
Job Retention (Hold, Proof, Store, PIN Printing) is
|
||
|
disabled. When eEnabled is specified, the Job Retention
|
||
|
characteristics of a given job are defined by the PJL
|
||
|
variable SET HOLD.
|
||
|
Additional information:
|
||
|
When disabled, currently held jobs are not removed,
|
||
|
but must be explicitly removed through the Control Panel
|
||
|
or the PML object HELD-JOB-DELETE."
|
||
|
::= { held-job-control 4 }
|
||
|
|
||
|
|
||
|
usage-printer-total-charge OBJECT-TYPE
|
||
|
SYNTAX REAL
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Total printer charge for all paper sizes printed."
|
||
|
::= { printer-accounting 2 }
|
||
|
|
||
|
|
||
|
usage-average-toner-coverage OBJECT-TYPE
|
||
|
SYNTAX REAL
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Reports the average toner area coverage of all pages
|
||
|
printed over the life of the device. Counts pixels on
|
||
|
each page, divides pixel count by pixels possible on a
|
||
|
page to give the percentage of coverage, and keeps a
|
||
|
rolling average percent weighted by area printed."
|
||
|
::= { printer-accounting 3 }
|
||
|
|
||
|
|
||
|
usage-staple-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..930576247)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Total number of staples used."
|
||
|
::= { printer-accounting 4 }
|
||
|
|
||
|
|
||
|
usage-instructions-line1 OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..40))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The first line of usage instructions for the device
|
||
|
user.Appears on Line 1 of the usage page."
|
||
|
::= { printer-accounting 5 }
|
||
|
|
||
|
|
||
|
usage-instructions-line2 OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..40))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The second line of usage instructions for the device
|
||
|
user.Appears on Line 1 of the usage page."
|
||
|
::= { printer-accounting 6 }
|
||
|
|
||
|
|
||
|
usage-instructions-line3 OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..40))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The third line of usage instructions for the device
|
||
|
user.Appears on Line 1 of the usage page."
|
||
|
::= { printer-accounting 7 }
|
||
|
|
||
|
|
||
|
usage-instructions-line4 OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..40))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The fourth line of usage instructions for the device
|
||
|
user.Appears on Line 1 of the usage page."
|
||
|
::= { printer-accounting 8 }
|
||
|
|
||
|
|
||
|
scanned-media-simplex-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..930576247)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Total number of simplex pages scanned, for this media
|
||
|
size.
|
||
|
Additional information:
|
||
|
The 5 usage (simplex/duplex count, simplex/duplex click
|
||
|
charge and paper size total) objects described here and
|
||
|
below detail the usage for the scanner for each paper
|
||
|
size defined in the PCL Implementor's Guide and in the
|
||
|
Media Size Table in the hpmib.txt. The OID binding is
|
||
|
based on the click attribute and paper size.
|
||
|
For example:
|
||
|
|
||
|
The format for the OID is as follows:
|
||
|
|
||
|
3.4.1.5.x.y
|
||
|
<-----> | |
|
||
|
| | \
|
||
|
/ | paper size
|
||
|
/ \
|
||
|
PRINTER-CLICK-TOTALS ROOT \
|
||
|
OID click attribute 1..5
|
||
|
|
||
|
x values are 1..5:
|
||
|
|
||
|
1) simplex count
|
||
|
2) simplex click charge
|
||
|
3) duplex count
|
||
|
4) duplex click charge
|
||
|
5) printer or scanner paper size total (i.e. depends if the
|
||
|
root OID is referrring to the printer or scanner).
|
||
|
|
||
|
y : paper size as defined in the Media Size Table in the
|
||
|
hpmib.txt
|
||
|
|
||
|
The click charge objects are of data type real and have a single
|
||
|
digit of precision. Setting these objects to more than a single
|
||
|
digit of precision will cause truncation at a single digit, for
|
||
|
example, if click charge is set to 15.475 and later retrieved with
|
||
|
a get, the value will be 15.400 for this object."
|
||
|
::= { scanned-media-usage 1 }
|
||
|
|
||
|
|
||
|
scanned-media-simplex-charge OBJECT-TYPE
|
||
|
SYNTAX REAL
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Charge for each simplex page printed in this media
|
||
|
size."
|
||
|
::= { scanned-media-usage 2 }
|
||
|
|
||
|
|
||
|
scanned-media-duplex-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..930576247)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Total number of duplex pages scanned, for this media
|
||
|
size."
|
||
|
::= { scanned-media-usage 3 }
|
||
|
|
||
|
|
||
|
scanned-media-duplex-charge OBJECT-TYPE
|
||
|
SYNTAX REAL
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Charge for each duplex page scanned, for this media
|
||
|
size."
|
||
|
::= { scanned-media-usage 4 }
|
||
|
|
||
|
|
||
|
scanned-media-total-charge OBJECT-TYPE
|
||
|
SYNTAX REAL
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The total charge for pages scanned, for this media
|
||
|
size."
|
||
|
::= { scanned-media-usage 5 }
|
||
|
|
||
|
|
||
|
usage-scanner-total-charge OBJECT-TYPE
|
||
|
SYNTAX REAL
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Total scanner charge or cost for all paper sizes
|
||
|
scanned."
|
||
|
::= { scanner-accounting 2 }
|
||
|
|
||
|
|
||
|
scanner-accessory-serial-number OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Identifies the serial number for the scanner accessory.
|
||
|
If this is a writable object, the POS should indicate
|
||
|
the maximum supported string length. This string should
|
||
|
only use characters from the US-ASCII code set.
|
||
|
Additional information:
|
||
|
The serial number is 5 digit decimal number."
|
||
|
::= { settings-scanner 18 }
|
||
|
|
||
|
|
||
|
scanner-accessory-model-number OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..32))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Model number of the scanner accessory. This string
|
||
|
should only use characters from the US-ASCII code set.
|
||
|
Additional information:
|
||
|
Model number for the Fujitsu scanner."
|
||
|
::= { settings-scanner 19 }
|
||
|
|
||
|
|
||
|
scanner-accessory-adf-sheet-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Total number of sheets that have been fed through the
|
||
|
Automatic Document Feed (ADF) accessory.
|
||
|
Additional information:
|
||
|
The Automatic Document Feed (ADF) count is
|
||
|
incremented each time a sheet feeds through the
|
||
|
ADF."
|
||
|
::= { settings-scanner 20 }
|
||
|
|
||
|
|
||
|
scanner-accessory-flatbed-scan-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Total number of scans performed by a flatbed scanner
|
||
|
accessory.
|
||
|
Additional information:
|
||
|
The count is only incremented when a sheet is
|
||
|
scanned on the FLATBED."
|
||
|
::= { settings-scanner 21 }
|
||
|
|
||
|
|
||
|
scanner-accessory-cleaning-interval OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Recommended cleaning interval in units of sheets
|
||
|
scanned.
|
||
|
Additional information:
|
||
|
Recommended cleaning interval is in units of sheets
|
||
|
scanned."
|
||
|
::= { settings-scanner 22 }
|
||
|
|
||
|
|
||
|
scanner-accessory-cleaning-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of sheets scanned since the last cleaning was
|
||
|
performed.
|
||
|
Additional information:
|
||
|
The number of sheets that have gone through the
|
||
|
ADF since the last cleaning was performed."
|
||
|
::= { settings-scanner 23 }
|
||
|
|
||
|
|
||
|
scanner-accessory-maintenance-interval OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Recommended maintenance interval in units of sheets
|
||
|
scanned.
|
||
|
Additional information:
|
||
|
Recommended maintenance interval is in units of sheets
|
||
|
scanned."
|
||
|
::= { settings-scanner 24 }
|
||
|
|
||
|
|
||
|
scanner-accessory-maintenance-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of sheets scanned since the last maintenance
|
||
|
was performed.
|
||
|
Additional information:
|
||
|
The number of sheets that have gone through the
|
||
|
ADF since the last maintenance was performed."
|
||
|
::= { settings-scanner 25 }
|
||
|
|
||
|
|
||
|
scanner-accessory-rom-revision OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..32))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"ROM revision of the scanner accessory firmware.
|
||
|
Additional information:
|
||
|
ROM revision of the Fujitsu scanner is
|
||
|
downloaded from the scanner after the attached
|
||
|
scanner establishes communications to the
|
||
|
printer."
|
||
|
::= { settings-scanner 26 }
|
||
|
|
||
|
|
||
|
scanner-accessory-copy-processor-boot-revision OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..32))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Boot ROM revision of scanner copy processor firmware.
|
||
|
Boot code to initialize the copy processor, establish
|
||
|
communications with the scanner, and load the runtime
|
||
|
code.
|
||
|
Additional information:
|
||
|
Boot ROM revision of the Pixel Magic - Copy
|
||
|
Processor firmware is downloaded from the scanner
|
||
|
after the attached scanner establishes
|
||
|
communications to the printer."
|
||
|
::= { settings-scanner 27 }
|
||
|
|
||
|
|
||
|
scanner-accessory-copy-processor-runtime-revision OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..32))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Revision of the runtime firmware for the scanner copy
|
||
|
processor. Runtime code which retrieves scanned data
|
||
|
from the scanner and sends it to other devices such as a
|
||
|
printer or PC host.
|
||
|
Additional information:
|
||
|
Revision of Pixel Magic - Copy Processor
|
||
|
firmware shipped on the disk which is download
|
||
|
into RAM for execution."
|
||
|
::= { settings-scanner 28 }
|
||
|
|
||
|
|
||
|
scanner-accessory-service-agent-revision OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..32))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Revision of scanner service agent firmware. Service
|
||
|
agent which accepts scanned data and processes scanner
|
||
|
copy processor requests, resident in a device such as a
|
||
|
printer or PC host.
|
||
|
Additional information:
|
||
|
Revision of the Scanner Service Agent firmware
|
||
|
shipped on the disk as a Service Provider entity
|
||
|
to retrieve scanned data from the scanner."
|
||
|
::= { settings-scanner 29 }
|
||
|
|
||
|
|
||
|
scanner-accessory-control-panel-user-interface-revision OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..32))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Revision of the control panel user interface firmware.
|
||
|
Additional information:
|
||
|
Revision of the copy processor user interface
|
||
|
firmware shipped on the disk."
|
||
|
::= { settings-scanner 30 }
|
||
|
|
||
|
|
||
|
scanner-accessory-nvram OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..40))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the contents of the NVRAM (Non-Volatile RAM)
|
||
|
located in the scanner accessory.
|
||
|
Additional information:
|
||
|
Read bytes 0..39 of the NVRAM in the
|
||
|
scanner. The Fujitsu Controller board has a
|
||
|
total of 128 bytes of NVRAM."
|
||
|
::= { settings-scanner 33 }
|
||
|
|
||
|
|
||
|
scanner-accessory-nvram2 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..40))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the second part of the contents of the NVRAM
|
||
|
(Non-Volatile RAM) located in the scanner accessory.
|
||
|
Additional information:
|
||
|
Read bytes 40..79 of the NVRAM in the
|
||
|
scanner. The Fujitsu Controller board has a
|
||
|
total of 128 bytes of NVRAM."
|
||
|
::= { settings-scanner 34 }
|
||
|
|
||
|
|
||
|
scanner-accessory-nvram3 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..40))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the third part of the contents of the NVRAM
|
||
|
(Non-Volatile RAM) located in the scanner accessory.
|
||
|
Additional information:
|
||
|
Read bytes 80..119 of the NVRAM in the
|
||
|
scanner. The Fujitsu Controller board has a
|
||
|
total of 128 bytes of NVRAM."
|
||
|
::= { settings-scanner 35 }
|
||
|
|
||
|
|
||
|
scanner-accessory-nvram4 OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1..8))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the fourth part of the contents of the NVRAM
|
||
|
(Non-Volatile RAM) located in the scanner accessory.
|
||
|
Additional information:
|
||
|
Read bytes 120..127 of the NVRAM in the
|
||
|
scanner. The Fujitsu Controller board has a
|
||
|
total of 128 bytes of NVRAM."
|
||
|
::= { settings-scanner 36 }
|
||
|
|
||
|
|
||
|
rpc-test-return-code OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This test object that will not be supported in any
|
||
|
released product. Setting this object allows the next
|
||
|
RPC call return code to be specified. The POS will
|
||
|
specify the binary format.
|
||
|
Additional information:
|
||
|
The format of the binary data is a one
|
||
|
of three formats. The first format is no binary
|
||
|
data, which indicates the next RPC reply should not
|
||
|
be modified. The other two formats are described in
|
||
|
RFC 1057 and encoded using XDR (i.e. the value is
|
||
|
the data used to instead of the actual RPC reply).
|
||
|
The second format is when reply-stat is MSG-ACCEPTED
|
||
|
and accept-stat is something other than SUCCESS.
|
||
|
The third format is when reply-stat is MSG-DENIED.
|
||
|
Notice that all RPC replies that do not contain any
|
||
|
'results' are supported."
|
||
|
::= { settings-rpc 1 }
|
||
|
|
||
|
|
||
|
rpc-bind-protocol-address OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Array of Berkeley sockets style protocol addresses used
|
||
|
to bind RPC to a communications protocol family.
|
||
|
Setting an instance of this array object to a zero
|
||
|
length binary value disables the transport protocol
|
||
|
indicated by that instance. All multi-bytes fields are
|
||
|
in network (or big-endian) order. Bytes 1 and 2
|
||
|
indicate the transport protocol. Some of the transport
|
||
|
protocol mapping information can be found in RFC 1010
|
||
|
Assigned Numbers. A list of interesting transport
|
||
|
protocol number mappings include:
|
||
|
Protocol | Number
|
||
|
---------+-------
|
||
|
UDP/IP | 17
|
||
|
IPX | 1000
|
||
|
MLC | 4660
|
||
|
Bytes 3 and 4 indicate the address family. The address
|
||
|
family uses the same mapping as the BSD sockets address
|
||
|
family. A list of interesting address family mappings
|
||
|
include:
|
||
|
Address Family | Number
|
||
|
---------------+-------
|
||
|
Internet | 2
|
||
|
NetWare | 6
|
||
|
MLC | 22136
|
||
|
The format the fifth and following bytes is dependent on
|
||
|
the address family. For the Internet address family,
|
||
|
bytes 5 and 6 contain the port number, bytes 7 through
|
||
|
10 contain the IP address, and the following eight bytes
|
||
|
are unused. For NetWare, bytes 5 through 8 are the
|
||
|
network number, bytes 9 through 14 are the node number,
|
||
|
and bytes 15 and 16 are the socket number.
|
||
|
Additional information:
|
||
|
The length of the binary value is zero
|
||
|
if the instance of an object in the rpc-bind-protocol-address
|
||
|
array is not in use. An unfortunate side effect of the
|
||
|
implementation is initializing the mass storage device sets this object
|
||
|
back to the factory default value.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { settings-rpc 2 }
|
||
|
|
||
|
|
||
|
rpc-statistic-successful OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A counter indicating the number of RPC requests that
|
||
|
completed successfully (reply-data stat is SUCCESS).
|
||
|
The POS should state if a power cycle causes the counter
|
||
|
is be reset to zero.
|
||
|
Additional information:
|
||
|
Reset to the factory default value after
|
||
|
a power cycle.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { status-rpc 1 }
|
||
|
|
||
|
|
||
|
rpc-statistic-unsuccessful OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A counter indicating the number of RPC requests that
|
||
|
completed unsuccessfully (reply-data stat is not
|
||
|
SUCCESS). The POS should state if a power cycle causes
|
||
|
the counter is be reset to zero.
|
||
|
Additional information:
|
||
|
Reset to the factory default value after
|
||
|
a power cycle.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { status-rpc 2 }
|
||
|
|
||
|
|
||
|
rpc-bound-protocol-address OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"An array of Berkeley sockets style protocol addresses
|
||
|
that the NFS service has been bound to successful. The
|
||
|
format is that same as the array of RPC-BIND-PROTOCOL-
|
||
|
ADDRESS of objects.
|
||
|
Additional information:
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { status-rpc 3 }
|
||
|
|
||
|
mount-test-return-code OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This test object that will not be supported in any
|
||
|
released product. Setting this object allows the next
|
||
|
mount call return code to be specified. The POS will
|
||
|
specify the binary format.
|
||
|
Additional information:
|
||
|
A one byte binary value. The
|
||
|
byte indicates what procedure is being effected by
|
||
|
this set.
|
||
|
value | function
|
||
|
------+------------------
|
||
|
1 | Mount will return an fhstatus of 0.
|
||
|
2 | Dump will return an empty table."
|
||
|
::= { settings-mount 1 }
|
||
|
|
||
|
nfs-server-memory OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The amount of memory, in bytes, used by the Network File
|
||
|
System server to buffer file data.
|
||
|
Additional information:
|
||
|
Reports the amount of memory, in bytes,
|
||
|
reserved for use by the NFS server. An unfortunate
|
||
|
side effect of the implementation is initializing
|
||
|
the mass storage device sets this object back to the factory
|
||
|
default value. Also includes the memory used by
|
||
|
other firmware components in addition to the NFS
|
||
|
server. Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { settings-nfs-server 1 }
|
||
|
|
||
|
|
||
|
nfs-server-read-size OBJECT-TYPE
|
||
|
SYNTAX INTEGER(256..1500)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum amount of data transferred in one NFS server
|
||
|
read data call.
|
||
|
Additional information:
|
||
|
An unfortunate side effect of the
|
||
|
implementation is initializing the mass storage device
|
||
|
sets this object back to the factory default value.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed. Rebooting causes
|
||
|
this value to reset to factory default.
|
||
|
value < 256 snaps to 256
|
||
|
value > 1500 snaps to 1500"
|
||
|
::= { settings-nfs-server 2 }
|
||
|
|
||
|
|
||
|
nfs-server-write-size OBJECT-TYPE
|
||
|
SYNTAX INTEGER(256..1500)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum amount of data transferred in one NFS server
|
||
|
write data call.
|
||
|
Additional information:
|
||
|
An unfortunate side effect of the
|
||
|
implementation is initializing the mass storage device sets this object
|
||
|
back to the factory default value.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { settings-nfs-server 3 }
|
||
|
|
||
|
|
||
|
nfs-server-test-return-code OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This test object that will not be supported in any
|
||
|
released product. Setting this object allows the next
|
||
|
NFS call return code to be specified. The POS will
|
||
|
specify the binary format.
|
||
|
Additional information:
|
||
|
A three byte binary value. The first
|
||
|
byte indicates what procedure is being effected by
|
||
|
this set.
|
||
|
value | function
|
||
|
------+------------------
|
||
|
1 | GetAttr
|
||
|
2 | SetAttr
|
||
|
3 | reserved
|
||
|
4 | Lookup
|
||
|
5 | reserved
|
||
|
6 | Read
|
||
|
7 | reserved
|
||
|
8 | Write
|
||
|
9 | Create
|
||
|
10 | Remove
|
||
|
11 | Rename
|
||
|
12 | reserved
|
||
|
13 | reserved
|
||
|
14 | MkDir
|
||
|
15 | RmDir
|
||
|
16 | ReadDir
|
||
|
17 | StatFS
|
||
|
The second byte is the stat value returned by the next
|
||
|
call to procedure specified by the value of the
|
||
|
first byte. The second byte can not be zero. Refer
|
||
|
to RFC 1094 for a list of stat values. The third byte
|
||
|
indicates
|
||
|
which call to the specified file system routine will
|
||
|
fail. A value of one means the first call will fail.
|
||
|
A value of two means the second call will fail, and
|
||
|
so on. Writing this object causes any previous write to
|
||
|
this object to be invalidated."
|
||
|
::= { settings-nfs-server 4 }
|
||
|
|
||
|
|
||
|
nfs-server-statistic-successful OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A counter indicating the number of NFS requests that
|
||
|
completed without error. The POS should state if a
|
||
|
power cycle causes the counter is be reset to zero.
|
||
|
Additional information:
|
||
|
Reset to the factory default value after
|
||
|
a power cycle.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { status-nfs-server 1 }
|
||
|
|
||
|
|
||
|
nfs-server-statistic-unsuccessful OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A counter indicating the number of NFS requests that
|
||
|
completed with an NFS status other than NFS-OK (0). The
|
||
|
POS should state if a power cycle causes the counter is
|
||
|
be reset to zero.
|
||
|
Additional information:
|
||
|
Reset to the factory default value after
|
||
|
a power cycle.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { status-nfs-server 2 }
|
||
|
|
||
|
|
||
|
nfs-server-statistic-current-memory-usage OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A value indicating the number of bytes of RAM currently
|
||
|
used by the NFS firmware.
|
||
|
Additional information:
|
||
|
Reset to the factory default value after
|
||
|
a power cycle.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { status-nfs-server 4 }
|
||
|
|
||
|
|
||
|
nfs-server-statistic-max-memory-usage OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A value indicating the maximum number of bytes of RAM
|
||
|
used by the NFS firmware. The POS should state if the
|
||
|
value is reset to zero after a power cycle.
|
||
|
Additional information:
|
||
|
Reset to the factory default value after
|
||
|
a power cycle.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { status-nfs-server 5 }
|
||
|
|
||
|
|
||
|
rpc-bind-test-return-code OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This test object that will not be supported in any
|
||
|
released product. Setting this object allows the next
|
||
|
RPC bind call return code to be specified. The POS will
|
||
|
specify the binary format.
|
||
|
Additional information:
|
||
|
A one byte value.
|
||
|
value | meaning
|
||
|
------+------------------
|
||
|
1 | Next GetPort or GetAddr will receive port 0
|
||
|
| (indicating the service is not supported).
|
||
|
2 | Next Dump will receive an empty table."
|
||
|
::= { settings-rpc-bind 1 }
|
||
|
|
||
|
|
||
|
rpc-bind-statistic-successful OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A counter indicating the number of RPC bind (RPC program
|
||
|
number 100000, version 2) requests that completed
|
||
|
successfully. The POS should state if a power cycle
|
||
|
causes the counter is be reset to zero.
|
||
|
Additional information:
|
||
|
Reset to the factory default value after
|
||
|
a power cycle.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { status-rpc-bind 1 }
|
||
|
|
||
|
|
||
|
rpc-bind-statistic-unsuccessful OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A counter indicating the number of RPC bind (RPC program
|
||
|
number 100000, version 2) requests that completed
|
||
|
unsuccessfully. The POS should state if a power cycle
|
||
|
causes the counter is be reset to zero.
|
||
|
Additional information:
|
||
|
Reset to the factory default value after
|
||
|
a power cycle.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { status-rpc-bind 2 }
|
||
|
|
||
|
|
||
|
xip-statistic-processed OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A counter indicating the number of XIP requests that
|
||
|
were processed. The POS should state if a power cycle
|
||
|
causes the counter is be reset to zero.
|
||
|
Additional information:
|
||
|
The number of XIP datagrams that have
|
||
|
been received by the XIP service. Reset to the
|
||
|
factory default value after a power cycle. Returns
|
||
|
<noSuchName> status if attempting
|
||
|
to access this object and there is no storage device
|
||
|
is installed."
|
||
|
::= { status-xip 1 }
|
||
|
|
||
|
|
||
|
xip-statistic-data-in-dropped OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A counter indicating the number of XIP data in datagrams
|
||
|
that were dropped (typically due to the printer being
|
||
|
flooded with XIP requests ). The POS should state if a
|
||
|
power cycle causes the counter is be reset to zero.
|
||
|
Additional information:
|
||
|
Reset to the factory default value after
|
||
|
a power cycle.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed."
|
||
|
::= { status-xip 2 }
|
||
|
|
||
|
|
||
|
prtinterpreterlangfamily OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePlangPCL(3),
|
||
|
ePlangPJL(5),
|
||
|
ePlangPS(6),
|
||
|
ePlangAutomatic(37),
|
||
|
ePlangPCLXL(47)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The family name of a Page Description Language (PDL) or
|
||
|
control language which this interpreter in the printer can
|
||
|
interpret or emulate.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
ePlangAutomatic refers to the `super-language'
|
||
|
made available by implicit language switching."
|
||
|
::= { prtInterpreterEntry 2 }
|
||
|
|
||
|
|
||
|
prtinterpreterlanglevel OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..31))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The level of the language which this interpreter is
|
||
|
interpreting or emulating. This might contain a value like
|
||
|
'5e' for an interpreter which is emulating level 5e of the PCL
|
||
|
language. It might contain '2' for an interpreter which is
|
||
|
emulating level 2 of the PostScript language. Similarly it
|
||
|
might contain '2' for an interpreter which is emulating level
|
||
|
2 of the HPGL language.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML PCL-VERSION."
|
||
|
::= { prtInterpreterEntry 3 }
|
||
|
|
||
|
|
||
|
prtinterpreterlangversion OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..31))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The date code or version of the language which this interpreter
|
||
|
is interpreting or emulating.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML FW-ROM-DATECODE, PJL-DATECODE,
|
||
|
PCL-DATECODE and PS-DATECODE
|
||
|
|
||
|
These values are derived from the dateCode field of the personality
|
||
|
entities. (ePlangAutomatic uses the PJL dateCode.)"
|
||
|
::= { prtInterpreterEntry 4 }
|
||
|
|
||
|
|
||
|
prtinterpreterdescription OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A string to identify this interpreter in the localization
|
||
|
specified by prtGeneralCurrentLocalization as opposed to the
|
||
|
language which is being interpreted. It is anticipated that
|
||
|
this string will allow manufacturers to unambiguously identify
|
||
|
their interpreters.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
These values are obtained from the persName fields
|
||
|
of the personality entities (except for the hard-coded value
|
||
|
of 'Automatic Language Switching'.)
|
||
|
|
||
|
These strings are not localized."
|
||
|
::= { prtInterpreterEntry 5 }
|
||
|
|
||
|
|
||
|
prtinterpreterversion OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..31))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The date code, version number, or other product specific
|
||
|
information tied to this interpreter. This value is
|
||
|
associated with the interpreter, rather than with the version
|
||
|
of the language which is being interpreted or emulated.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Same as prtInterpreterLangVersion."
|
||
|
::= { prtInterpreterEntry 6 }
|
||
|
|
||
|
|
||
|
prtinterpreterdefaultorientation OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePportrait(3),
|
||
|
ePlandscape(4)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The current orientation default for this interpreter. This
|
||
|
value may be overridden for a particular job (e.g., by a
|
||
|
command in the input data stream).
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The value of the system's DEFAULT-ORIENTATION is
|
||
|
set or retrieved without regard to interpreters. Setting this
|
||
|
object for one interpreter will change it for all installed
|
||
|
interpreters.
|
||
|
|
||
|
The valid values are ePportrait and ePlandscape. Attempting
|
||
|
to set the orientation to a different value will cause
|
||
|
<badValue> to be returned."
|
||
|
::= { prtInterpreterEntry 7 }
|
||
|
|
||
|
|
||
|
prtinterpreterfeedaddressability OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum interpreter addressability in the feed
|
||
|
direction in 10000 prtMarkerAddressabilityUnits (see
|
||
|
prtMarkerAddressabilityFeedDir ) for this interpreter.
|
||
|
The value (-1) means other and specifically indicates
|
||
|
that the sub-unit places no restrictions on this parameter.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtInterpreterEntry 8 }
|
||
|
|
||
|
|
||
|
prtinterpreterxfeedaddressability OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum interpreter addressability in the cross feed
|
||
|
direction in 10000 prtMarkerAddressabilityUnits (see
|
||
|
prtMarkerAddressabilityXFeedDir) for this interpreter.
|
||
|
The value (-1) means other and specifically indicates
|
||
|
that the sub-unit places no restrictions on this
|
||
|
parameter.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtInterpreterEntry 9 }
|
||
|
|
||
|
|
||
|
prtinterpreterdefaultcharsetin OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePcsASCII(3),
|
||
|
ePcsISOLatin1(4),
|
||
|
ePcsISOLatin2(5),
|
||
|
ePcsISOLatin5(12),
|
||
|
ePcsISOLatin6(13),
|
||
|
ePcsISO4UnitedKingdom(20),
|
||
|
ePcsISO11SwedishforNames(21),
|
||
|
ePcsISO15Italian(22),
|
||
|
ePcsISO17Spanish(23),
|
||
|
ePcsISO21German(24),
|
||
|
ePcsISO60DanishNorwegian(25),
|
||
|
ePcsISO69French(26),
|
||
|
ePcsUnicodeIBM2039(1004),
|
||
|
ePcsWindows30Latin1(2000),
|
||
|
ePcsWindows31Latin1(2001),
|
||
|
ePcsWindows31Latin2(2002),
|
||
|
ePcsWindows31Latin5(2003),
|
||
|
ePcsHPRoman8(2004),
|
||
|
ePcsAdobeStandardEncoding(2005),
|
||
|
ePcsPC850Multilingual(2009),
|
||
|
ePcsPCp852(2010),
|
||
|
ePcsPC8CodePage437(2011),
|
||
|
ePcsPC8DNDanishNorwegian(2012),
|
||
|
ePcsHPPC8Turkish(2014),
|
||
|
ePcsHPLegal(2017),
|
||
|
ePcsHPDeskTop(2021),
|
||
|
ePcsMacintosh(2027),
|
||
|
ePcsPC775Baltic(2087),
|
||
|
ePcsWindows1257Baltic(2257)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The default coded character set for input octets
|
||
|
encountered outside a context in which the Page
|
||
|
Description Language established the interpretation
|
||
|
of the octets. (Input octets are presented to the
|
||
|
interpreter through a path defined in the channel group.)
|
||
|
This value shall be (2) if there is no default.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The object corresponding to PCL has read-write access;
|
||
|
For all other interpreters, the object is read-only.
|
||
|
|
||
|
The above list corresponds to the following symbol sets as they
|
||
|
appear on the Control Panel:
|
||
|
|
||
|
ePcsASCII( 3) - ISO-6
|
||
|
ePcsISOLatin1( 4) - ISO L1
|
||
|
ePcsISOLatin2( 5) - IS L2
|
||
|
ePcsISOLatin5( 12) - ISO L5
|
||
|
ePcsISOLatin6( 13) - ISO L6
|
||
|
ePcsISO4UnitedKingdom( 20) - ISO-4
|
||
|
ePcsISO11SwedishforNames( 21) - ISO-11
|
||
|
ePcsISO15Italian( 22) - ISO-15
|
||
|
ePcsISO17Spanish( 23) - ISO-17
|
||
|
ePcsISO21German( 24) - ISO-21
|
||
|
ePcsISO60DanishNorwegian( 25) - ISO-60
|
||
|
ePcsISO69French( 26) - ISO-69
|
||
|
ePcsUnicodeIBM2039(1004) - PC-1004
|
||
|
ePcsWindows30Latin1( 2000) - WIN 3.0
|
||
|
ePcsWindows31Latin1( 2001) - WIN L1
|
||
|
ePcsWindows31Latin2( 2002) - WIN L2
|
||
|
ePcsWindows31Latin5( 2003) - WIN L5
|
||
|
ePcsHPRoman8( 2004) - ROMAN-8
|
||
|
ePcsAdobeStandardEncoding( 2005) - PS TEXT
|
||
|
ePcsPC850Multilingual( 2009) - PC-850
|
||
|
ePcsPCp852( 2010) - PC-852
|
||
|
ePcsPC8CodePage437( 2011) - PC-8
|
||
|
ePcsPC8DNDanishNorwegian( 2012) - PC-8DN
|
||
|
ePcsHPPC8Turkish( 2014) - PC-8 TK
|
||
|
ePcsHPLegal( 2017) - LEGAL
|
||
|
ePcsHPDeskTop( 2021) - DESKTOP
|
||
|
ePcsMacintosh(2027) - MC TEXT
|
||
|
ePcsPC775Baltic( 2087) - PC-775
|
||
|
ePcsWindows1257Baltic( 2257) - WINBALT"
|
||
|
::= { prtInterpreterEntry 10 }
|
||
|
|
||
|
|
||
|
prtinterpreterdefaultcharsetout OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePcsNoDefault(2),
|
||
|
ePcsASCII(3),
|
||
|
ePcsHPRoman8(2004),
|
||
|
ePcsAdobeStandardEncoding(2005)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The default character set for data coming from this interpreter
|
||
|
through the printer's output channel (i.e. the 'backchannel').
|
||
|
This value shall be (2) if there is no default.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtInterpreterEntry 11 }
|
||
|
|
||
|
|
||
|
prtinterpretertwoway OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePyes(3),
|
||
|
ePno(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates whether or not this interpreter returns information
|
||
|
back to the host.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtInterpreterEntry 12 }
|
||
|
|
||
|
|
||
|
energy-star OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the Energy Star sleep value. If the
|
||
|
value is greater than zero, then the device will go into
|
||
|
energy saving sleep mode after the print engine has been
|
||
|
idle for the number of seconds specified by this object.
|
||
|
A value of zero means Energy Star is disabled and the
|
||
|
device will not go to sleep based on print engine idle
|
||
|
time. The value must be non-negative.
|
||
|
Additional information:
|
||
|
Returns or changes the Energy Star sleep value.
|
||
|
The device will go into energy saving sleep
|
||
|
mode after the print engine has been idle for
|
||
|
the number of seconds specified by this
|
||
|
object.
|
||
|
|
||
|
LaserJet 4050 Series supports values of 0, 900, 1800,
|
||
|
3600, 7200, and 10800. A value of 0 means
|
||
|
never go to sleep based on print engine idle
|
||
|
time. Setting to an unsupported value causes
|
||
|
the printer to substitute a value (listed
|
||
|
below) and to return <noError>
|
||
|
status.
|
||
|
The values are as follow:
|
||
|
<=0 snap to 0
|
||
|
>=1 and <=1349 snap to 900 (15 minutes)
|
||
|
>=1350 and <=2699 snap to 1800 (30 minutes)
|
||
|
>=2700 and <=5399 snap to 3600 (1 hour)
|
||
|
>=5400 and <=8999 snap to 7200 (2 hours)
|
||
|
>=9000 snap to 10800 (3 hours)"
|
||
|
::= { settings-system 1 }
|
||
|
|
||
|
sleep-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eFalse(1),
|
||
|
eTrue(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns eTrue if the device is in energy saving sleep
|
||
|
mode, otherwise returns eFalse. Setting SLEEP-MODE to
|
||
|
eFalse causes the device to wake up, if it is in sleep
|
||
|
mode. Setting SLEEP-MODE to eTrue causes the device to
|
||
|
go into sleep mode.
|
||
|
Additional information:
|
||
|
This object returns eTrue if the device is in
|
||
|
energy saving sleep mode, otherwise it returns eFalse.
|
||
|
Setting this object to eTrue while the printer
|
||
|
is awake will not change the printer's current state
|
||
|
and will return <genErr>
|
||
|
status. NOTE: This object should behave this way
|
||
|
when the printer does not have an instant-on fuser.
|
||
|
Setting this object to eTrue while printer is already
|
||
|
in Sleep Mode will not change the printer's
|
||
|
current state and will return <noError> status.
|
||
|
Setting this object to eFalse while printer is already
|
||
|
awake will not change the printer's current state and
|
||
|
will return <noError> status.
|
||
|
Setting this object to eFalse while the printer is
|
||
|
asleep causes the device to wake up. "
|
||
|
::= { settings-system 2 }
|
||
|
|
||
|
control-panel-lock OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eDisabled(1),
|
||
|
eEnabled(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Device control panel lock. A value of eDisabled means
|
||
|
the control panel is unlocked and the device's
|
||
|
configuration can be modified from the control panel. A
|
||
|
value of eEnabled means the control panel is locked,
|
||
|
thus the device's configuration cannot be modified from
|
||
|
the control panel."
|
||
|
::= { settings-system 8 }
|
||
|
|
||
|
run-location OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..9)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or changes the location from which code
|
||
|
executes. The object allows the user to pick a memory
|
||
|
bank to run code from which is different than the
|
||
|
default running code bank. A value of 0 means the code
|
||
|
executes from the default code bank, which should be
|
||
|
documented in the device POS. The list of supported
|
||
|
values should be documented in the device POS. Setting
|
||
|
to an unsupported value causes the device to return
|
||
|
<badValue>.
|
||
|
Additional information:
|
||
|
Returns or changes the location from which code
|
||
|
should be run. The object allows the user to pick a ram bank
|
||
|
to run code from which is potentially faster than the onboard
|
||
|
ROM. LaserJet 8100 Series and LaserJet 8000 Series support values of 0,4-9. A value of 0
|
||
|
means run code from default ROM device. Values other than 0
|
||
|
indicate a valid RAM bank of size >= 8MBs. Setting to an
|
||
|
unsupported value causes the printer to leave the run location
|
||
|
set to its previous value."
|
||
|
::= { settings-system 21 }
|
||
|
|
||
|
model-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(1..32))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Identifies the device model name (e.g. ''DeskJet
|
||
|
1200C''). The string is as specific as possible.
|
||
|
Capitalization and spacing should match family naming
|
||
|
conventions. Products should note in POS if the model
|
||
|
name on the HP corporate price list changes but the
|
||
|
device reports the previous device name. If the model
|
||
|
name changes based on the installed options, the POS
|
||
|
should indicate if only the base model name is returned,
|
||
|
or if the device senses the installed options and
|
||
|
returns the correct model name. If possible, encode the
|
||
|
model name in a symbol set (like Roman-8) that matches
|
||
|
the ASCII character set and limit the characters used to
|
||
|
ASCII characters.
|
||
|
Additional information:
|
||
|
Since the value of this object is frequently used in
|
||
|
displaying a list of printers, it is kept relatively short in
|
||
|
case systems have limited width for their display area. The
|
||
|
model name does not change based on sensing of installed options."
|
||
|
::= { id 2 }
|
||
|
|
||
|
|
||
|
device-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..32))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"User defined device name. The POS should indicate the
|
||
|
maximum supported string length. If the user entered
|
||
|
string is too long, the device will store as much as
|
||
|
possible and will return the <noError>.
|
||
|
|
||
|
Additional information:
|
||
|
The maximum supported string length is 32
|
||
|
characters. If the user entered string is too long,
|
||
|
the device will store the first 32 characters and will
|
||
|
return the <noError> status."
|
||
|
::= { id 10 }
|
||
|
|
||
|
|
||
|
simm1-bank1-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eUnSupported(3),
|
||
|
eReadOnlyMemory(4),
|
||
|
eFlashMemory(7),
|
||
|
eSDRandomAccessMemory(14),
|
||
|
eSRandomAccessMemory(15),
|
||
|
eFPMRandomAccessMemory(16),
|
||
|
eEDORandomAccessMemory(17)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
Bank 1 of SIMM slot 1. See SIMM1-TYPE for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
This object is used for describing the type
|
||
|
of DIMM banks. Each physical DIMM slot has up to 2 banks."
|
||
|
::= { simm1-bank1 1 }
|
||
|
|
||
|
|
||
|
simm1-bank1-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of Bank 1 of the
|
||
|
SIMM installed in SIMM slot 1. See SIMM1-CAPACITY for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
Returns an indication of the capacity of the
|
||
|
installed bank option in bytes. This object is not
|
||
|
supported unless the SIMM1-BANK1-TYPE type is
|
||
|
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
|
||
|
eSDRandomAccessMemory, eSRandomAccessMemory,
|
||
|
or eFPMRandomAccessMemory."
|
||
|
::= { simm1-bank1 2 }
|
||
|
|
||
|
|
||
|
simm1-bank2-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eUnSupported(3),
|
||
|
eReadOnlyMemory(4),
|
||
|
eFlashMemory(7),
|
||
|
eSDRandomAccessMemory(14),
|
||
|
eSRandomAccessMemory(15),
|
||
|
eFPMRandomAccessMemory(16),
|
||
|
eEDORandomAccessMemory(17)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
Bank 2 of SIMM slot 1. See SIMM1-TYPE for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
This object is used for describing the type
|
||
|
of DIMM banks. Each physical DIMM slot has up to 2 banks."
|
||
|
::= { simm1-bank2 1 }
|
||
|
|
||
|
|
||
|
simm1-bank2-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of Bank 2 of the
|
||
|
SIMM installed in SIMM slot 1. See SIMM1-CAPACITY for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
Returns an indication of the capacity of the
|
||
|
installed bank option in bytes. This object is not
|
||
|
supported unless the SIMM1-BANK2-TYPE type is
|
||
|
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
|
||
|
eSDRandomAccessMemory, eSRandomAccessMemory,
|
||
|
or eFPMRandomAccessMemory."
|
||
|
::= { simm1-bank2 2 }
|
||
|
|
||
|
|
||
|
simm2-bank1-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eUnSupported(3),
|
||
|
eReadOnlyMemory(4),
|
||
|
eFlashMemory(7),
|
||
|
eSDRandomAccessMemory(14),
|
||
|
eSRandomAccessMemory(15),
|
||
|
eFPMRandomAccessMemory(16),
|
||
|
eEDORandomAccessMemory(17)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
Bank 1 of SIMM slot 2. See SIMM1-TYPE for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
This object is used for describing the type
|
||
|
of DIMM banks. Each physical DIMM slot has up to 2 banks."
|
||
|
::= { simm2-bank1 1 }
|
||
|
|
||
|
|
||
|
simm2-bank1-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of Bank 1 of the
|
||
|
SIMM installed in SIMM slot 2. See SIMM1-CAPACITY for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
Returns an indication of the capacity of the
|
||
|
installed bank option in bytes. This object is not
|
||
|
supported unless the SIMM2-BANK1-TYPE type is
|
||
|
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
|
||
|
eSDRandomAccessMemory, eSRandomAccessMemory,
|
||
|
or eFPMRandomAccessMemory."
|
||
|
::= { simm2-bank1 2 }
|
||
|
|
||
|
|
||
|
simm2-bank2-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eUnSupported(3),
|
||
|
eReadOnlyMemory(4),
|
||
|
eFlashMemory(7),
|
||
|
eSDRandomAccessMemory(14),
|
||
|
eSRandomAccessMemory(15),
|
||
|
eFPMRandomAccessMemory(16),
|
||
|
eEDORandomAccessMemory(17)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
Bank 2 of SIMM slot 2. See SIMM1-TYPE for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
This object is used for describing the type
|
||
|
of DIMM banks. Each physical DIMM slot has up to 2 banks."
|
||
|
::= { simm2-bank2 1 }
|
||
|
|
||
|
|
||
|
simm2-bank2-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of Bank 2 of the
|
||
|
SIMM installed in SIMM slot 2. See SIMM1-CAPACITY for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
Returns an indication of the capacity of the
|
||
|
installed bank option in bytes. This object is not
|
||
|
supported unless the SIMM2-BANK2-TYPE type is
|
||
|
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
|
||
|
eSDRandomAccessMemory, eSRandomAccessMemory,
|
||
|
or eFPMRandomAccessMemory."
|
||
|
::= { simm2-bank2 2 }
|
||
|
|
||
|
|
||
|
simm3-bank1-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eUnSupported(3),
|
||
|
eReadOnlyMemory(4),
|
||
|
eFlashMemory(7),
|
||
|
eSDRandomAccessMemory(14),
|
||
|
eSRandomAccessMemory(15),
|
||
|
eFPMRandomAccessMemory(16),
|
||
|
eEDORandomAccessMemory(17)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
Bank 1 of SIMM slot 3. See SIMM1-TYPE for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
This object is used for describing the type
|
||
|
of DIMM banks. Each physical DIMM slot has up to 2 banks."
|
||
|
::= { simm3-bank1 1 }
|
||
|
|
||
|
|
||
|
simm3-bank1-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of Bank 1 of the
|
||
|
SIMM installed in SIMM slot 3. See SIMM1-CAPACITY for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
Returns an indication of the capacity of the
|
||
|
installed bank option in bytes. This object is not
|
||
|
supported unless the SIMM3-BANK1-TYPE type is
|
||
|
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
|
||
|
eSDRandomAccessMemory, eSRandomAccessMemory,
|
||
|
or eFPMRandomAccessMemory."
|
||
|
::= { simm3-bank1 2 }
|
||
|
|
||
|
|
||
|
simm3-bank2-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eUnknown(2),
|
||
|
eUnSupported(3),
|
||
|
eReadOnlyMemory(4),
|
||
|
eFlashMemory(7),
|
||
|
eSDRandomAccessMemory(14),
|
||
|
eSRandomAccessMemory(15),
|
||
|
eFPMRandomAccessMemory(16),
|
||
|
eEDORandomAccessMemory(17)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed in
|
||
|
Bank 2 of SIMM slot 3. See SIMM1-TYPE for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
This object is used for describing the type
|
||
|
of DIMM banks. Each physical DIMM slot has up to 2 banks."
|
||
|
::= { simm3-bank2 1 }
|
||
|
|
||
|
|
||
|
simm3-bank2-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of Bank 2 of the
|
||
|
SIMM installed in SIMM slot 3. See SIMM1-CAPACITY for a
|
||
|
description.
|
||
|
Additional information:
|
||
|
Returns an indication of the capacity of the
|
||
|
installed bank option in bytes. This object is not
|
||
|
supported unless the SIMM3-BANK2-TYPE type is
|
||
|
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
|
||
|
eSDRandomAccessMemory, eSRandomAccessMemory,
|
||
|
or eFPMRandomAccessMemory."
|
||
|
::= { simm3-bank2 2 }
|
||
|
|
||
|
|
||
|
ram-disk-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOff(1),
|
||
|
eOn(2),
|
||
|
eAuto(3)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or controls RAM disk support. eOFF turns off
|
||
|
the RAM disk functionality. eOn turns on the RAM disk
|
||
|
functionality and creates a RAM disk whose size is
|
||
|
controlled by the RAM-DISK-SIZE object. eAuto turns on
|
||
|
the RAM disk functionality and creates a RAM disk size
|
||
|
determined by the printer based on installed options and
|
||
|
other memory related settings.
|
||
|
Additional information:
|
||
|
Returns or controls RAM disk support. eOFF turns off
|
||
|
the RAM disk functionality. eOn turns on the RAM disk
|
||
|
functionality and creates a RAM disk whose size is
|
||
|
controlled by the RAM-DISK-SIZE object. eAuto turns on
|
||
|
the RAM disk functionality and creates a RAM disk size
|
||
|
determined by the printer based on the amount of installed
|
||
|
memory. The automatic size will be 25 percent of all memory
|
||
|
above 4MB."
|
||
|
::= { settings-mass-storage-bd 1 }
|
||
|
|
||
|
|
||
|
ram-disk-size OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or controls the size of the RAM disk. The
|
||
|
device POS specifies the minimum memory requirements.
|
||
|
The object MAXIMUM-RAM-DISK-MEMORY specifies the maximum
|
||
|
memory available for the RAM disk.
|
||
|
Additional information:
|
||
|
Returns or controls the size of the RAM disk. The values
|
||
|
that can be set depend on the current setting of the
|
||
|
RAM-DISK-MODE object, and the amount of memory available
|
||
|
above 4MB. Use the MAXIMUM-RAM-DISK-MEMORY object to
|
||
|
determine the amount of additional memory available
|
||
|
for the RAM disk."
|
||
|
::= { settings-mass-storage-bd 2 }
|
||
|
|
||
|
|
||
|
maximum-ram-disk-memory OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object's name is misleading. This object does not
|
||
|
return the maximum configurable RAM disk size. Instead,
|
||
|
it returns the maximum amount of memory, in bytes, that
|
||
|
can used to increase the size of the RAM disk.
|
||
|
Additional information:
|
||
|
This object returns the maximum amount of additional
|
||
|
memory that is available for increasing the size of the RAM
|
||
|
disk."
|
||
|
::= { status-mass-storage-bd 1 }
|
||
|
|
||
|
disk-storage-block-driver2-test-return-code OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This test object will not be supported in any released
|
||
|
product. Setting this object allows the next call to
|
||
|
the mass storage block driver 2 to return the specified
|
||
|
code. The POS will specify the binary format.
|
||
|
Additional information:
|
||
|
The hrDeviceIndex value for the mass storage
|
||
|
device is the same value that is used to index into the
|
||
|
DISK-STORAGE-BLOCK-DRIVERS sub-tree. Since this product
|
||
|
only supports one mass storage device, the hrDeviceIndex
|
||
|
for the mass storage device will be 2 if the mass storage device is
|
||
|
installed. The value is a two byte value. The value
|
||
|
of the first byte indicates the return code, as described
|
||
|
in the following table:
|
||
|
value | meaning
|
||
|
------+------------------
|
||
|
1 | After the next power cycle, indicate the
|
||
|
| mass storage device is not installed. Only affects the
|
||
|
| printer state after the next power cycle.
|
||
|
2 | After the next power cycle, indicate the
|
||
|
| mass storage device is not initialized. Changes the
|
||
|
| contents of the mass storage device so the mass storage device becomes
|
||
|
| uninitialized.
|
||
|
3 | After the next power cycle, indicate the
|
||
|
| mass storage device is defective. Only affects the
|
||
|
| printer state after the next power cycle.
|
||
|
4 | Cause the specified call to the read block
|
||
|
| routine to indicate read failure.
|
||
|
5 | Cause the specified call to the write block
|
||
|
| routine to indicate write failure.
|
||
|
6 | After the next power cycle, indicate the
|
||
|
| mass storage device failed the power-on self-test, but
|
||
|
| completed the initialization sequence
|
||
|
| successfully. Only affects the
|
||
|
| printer state after the next power cycle.
|
||
|
7 | Cause the driver to behave, after the next power
|
||
|
| cycle, as if the mass storage device had the serial number
|
||
|
| 'SN00000000'. This is a one-shot effect and the
|
||
|
| driver reverts to normal behavior if the printer
|
||
|
| is power cycled a second time.
|
||
|
The second byte indicates on which call to the specified
|
||
|
block driver the failure will start to occur.
|
||
|
If the value of the first bytes is four or five, then the
|
||
|
value of the second byte in indicates which call to the
|
||
|
specified block driver routine will fail. A value of one
|
||
|
means the first call will fail. A value of two means the
|
||
|
second call will fail, and so on. If the value of the
|
||
|
first byte is one, two, three, six, or seven, then the
|
||
|
value of the second byte is ignored. Writing this object
|
||
|
causes any previous write to this object to be invalidated."
|
||
|
::= { settings-msbd2 1 }
|
||
|
|
||
|
mopy-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eOff(1),
|
||
|
eStandard(4),
|
||
|
eEnhanced(5)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Controls or reports how mopies are generated. eOff
|
||
|
turns off the mopy feature. eAuto allows the device to
|
||
|
determine the best method for generating mopies based on
|
||
|
the device configuration. eStandard spools the I/O data
|
||
|
and replays the I/O data multiple times to generate the
|
||
|
mopies. eEnhanced spools the rasterized page images and
|
||
|
replays the rasterized data to generate the mopies.
|
||
|
Typically, the rasterized data will be larger and will
|
||
|
allow all but the first mopy to print at speed. If the
|
||
|
job being mopied is not extremely complex, then the
|
||
|
first mopy will print at speed also."
|
||
|
::= { settings-spooler 1 }
|
||
|
|
||
|
|
||
|
engine-media-modes-supported1 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The list of engine media modes supported by the device.
|
||
|
The modes are each separated by a comma character. An
|
||
|
example string would be: 'Normal,Rough,Low,Vellum'."
|
||
|
::= { media-modes 1 }
|
||
|
|
||
|
|
||
|
hrmemorysize OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The amount of physical main memory contained by
|
||
|
the host.
|
||
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
|
Additional information:
|
||
|
The unit of measure for this object is 1024 bytes.
|
||
|
The default value assumes the base printer with no
|
||
|
additional memory."
|
||
|
::= { hrStorage 2 }
|
||
|
|
||
|
|
||
|
prtconsolecolor OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePunknown(2),
|
||
|
ePwhite(3),
|
||
|
ePred(4),
|
||
|
ePgreen(5),
|
||
|
ePblue(6),
|
||
|
ePcyan(7),
|
||
|
ePmagenta(8),
|
||
|
ePyellow(9),
|
||
|
ePorange(10)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The color of this light.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtConsoleLightEntry 4 }
|
||
|
|
||
|
|
||
|
phd1-model OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns product information identifying the PHD device.
|
||
|
Example: XXXX"
|
||
|
::= { phd1 1 }
|
||
|
|
||
|
|
||
|
phd1-manufacturing-info OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns information describing the manufacture of this
|
||
|
particular PHD. May include serial number and firmware
|
||
|
revision."
|
||
|
::= { phd1 2 }
|
||
|
|
||
|
|
||
|
phd1-type OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eEmpty(1),
|
||
|
eInputPHD(10)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the type of option installed as
|
||
|
PHD 1. See SIMM1-TYPE for an explanation of the
|
||
|
enumerations.
|
||
|
Additional information:
|
||
|
Returns an indication of whether or not the
|
||
|
envelope feeder is installed on the printer. A value of eEmpty means that
|
||
|
the envelope feeder is not installed."
|
||
|
::= { phd1 3 }
|
||
|
|
||
|
|
||
|
phd1-capacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns an indication of the capacity of the installed
|
||
|
option. See SIMM1-CAPACITY for an explanation of the
|
||
|
meaning of the value of this object.
|
||
|
Additional information:
|
||
|
The LaserJet 4000 Series envelope feeder has a single tray."
|
||
|
::= { phd1 4 }
|
||
|
|
||
|
|
||
|
override-media-size OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUSExecutive(1),
|
||
|
eUSLetter(2),
|
||
|
eUSLegal(3),
|
||
|
eISOandJISA5(25),
|
||
|
eISOandJISA4(26),
|
||
|
eJISB5(45),
|
||
|
eMonarch(80),
|
||
|
eCommercial10(81),
|
||
|
eInternationalDL(90),
|
||
|
eInternationalC5(91),
|
||
|
eInternationalB5(100),
|
||
|
eCustom(101)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Sets the media size that is to be used in place of the
|
||
|
currently requested media size.
|
||
|
Additional information:
|
||
|
When a request is received to print on a size and
|
||
|
type of media that is not currently available, this object contains the
|
||
|
desired size as set by the print job. This object should be set to a media
|
||
|
size that is currently available to the printer.
|
||
|
If a paper mount request is not pending, attempting to get or set this object
|
||
|
will cause <noSuchName> to be returned."
|
||
|
::= { settings-prt-eng 3 }
|
||
|
|
||
|
|
||
|
custom-paper-feed-dim OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Sets the printer's custom paper dimension in the feed
|
||
|
direction (direction parallel to the direction of paper
|
||
|
feeding). The value for this object is specified in
|
||
|
micrometers or tenthousandths of an inch, depending upon
|
||
|
the value of CUSTOM-PAPER-DIM-UNIT. The valid range is
|
||
|
engine-dependent and should be documented in the POS for
|
||
|
each product.
|
||
|
Additional information:
|
||
|
The valid range for LaserJet 4000 Series is 50000 to 140000 if
|
||
|
CUSTOM-PAPER-DIM-UNIT is eTenThousandthsOfInches or
|
||
|
127000 to 355600 if CUSTOM-PAPER-DIM-UNIT is ePmicrometers.
|
||
|
Attempts to set this object outside the valid range will result
|
||
|
in a return value of <badValue>."
|
||
|
::= { settings-intray 8 }
|
||
|
|
||
|
|
||
|
custom-paper-xfeed-dim OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Sets the printer's custom paper dimension in the cross-
|
||
|
feed direction (direction ninety degrees relative to the
|
||
|
direction of paper feeding). The value for this object
|
||
|
is specified in micrometers or tenthousandths of an
|
||
|
inch, depending upon the value of CUSTOM-PAPER-DIM-UNIT.
|
||
|
The valid range is engine-dependent and should be
|
||
|
documented in the POS for each product.
|
||
|
Additional information:
|
||
|
The valid range for LaserJet 4000 Series is 30000 to 85000 if
|
||
|
CUSTOM-PAPER-DIM-UNIT is eTenThousandthsOfInches or
|
||
|
76200 to 215900 if CUSTOM-PAPER-DIM-UNIT is ePmicrometers.
|
||
|
Attempts to set this object outside the valid range will result
|
||
|
in a return value of <badValue>."
|
||
|
::= { settings-intray 9 }
|
||
|
|
||
|
tray1-media-size-loaded OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUSExecutive(1),
|
||
|
eUSLetter(2),
|
||
|
eUSLegal(3),
|
||
|
eLedger(11),
|
||
|
eISOandJISA4(26),
|
||
|
eISOandJISA3(27),
|
||
|
eJISB5(45),
|
||
|
eJISB4(46),
|
||
|
eJapanesePostcardSingle(71),
|
||
|
eJapanesePostcardDouble(72),
|
||
|
eMonarch(80),
|
||
|
eCommercial10(81),
|
||
|
eInternationalDL(90),
|
||
|
eInternationalC5(91),
|
||
|
eInternationalB5(100),
|
||
|
eCustom(101)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the media size that is currently loaded in tray
|
||
|
#1. This object can be set to indicate the media size
|
||
|
currently loaded, if the printer supports input trays
|
||
|
that can not sense the media size. Complete list of
|
||
|
supported media sizes along with their dimensions are
|
||
|
listed in the ``Media Size Table'' near the end of this
|
||
|
document."
|
||
|
::= { intray1 1 }
|
||
|
|
||
|
|
||
|
tray1-media-available OBJECT-TYPE
|
||
|
SYNTAX INTEGER(-1..100)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns a number that indicates how full the input tray
|
||
|
is. If the device can only detect empty / not empty the
|
||
|
device returns -1 for not empty and 0 for empty. If the
|
||
|
device can determine how full the tray is, the device
|
||
|
returns a percentage full from 0% to 100%
|
||
|
Additional information:
|
||
|
LaserJet 4V can only detect empty/not empty tray.
|
||
|
It returns -1 for not empty and 0 for empty."
|
||
|
::= { intray1 2 }
|
||
|
|
||
|
|
||
|
tray1-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the device specific name for tray 1."
|
||
|
::= { intray1 3 }
|
||
|
|
||
|
|
||
|
tray2-media-size-loaded OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUSExecutive(1),
|
||
|
eUSLetter(2),
|
||
|
eUSLegal(3),
|
||
|
eLedger(11),
|
||
|
eISOandJISA4(26),
|
||
|
eISOandJISA3(27),
|
||
|
eJISB5(45),
|
||
|
eJISB4(46),
|
||
|
eCustom(101),
|
||
|
eUnknownMediaSize(32767)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the media size that is currently configured in
|
||
|
tray #2. Complete list of supported media sizes along
|
||
|
with their dimensions are listed in the ''Media Size
|
||
|
Table'' near the end of this document.
|
||
|
Additional information:
|
||
|
If the tray drawer is open, a get on this object
|
||
|
will cause a status of
|
||
|
<genErr> to be
|
||
|
returned. If the tray is empty, the size that the
|
||
|
tray is configured for will be returned. If Tray 2
|
||
|
is a 500-sheet standard tray, eJISB5 and eUSExecutive
|
||
|
are not valid values."
|
||
|
::= { intray2 1 }
|
||
|
|
||
|
tray2-media-available OBJECT-TYPE
|
||
|
SYNTAX INTEGER(-1..100)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns a number that indicates how full the input tray
|
||
|
is. If the device can only detect empty / not empty the
|
||
|
device returns -1 for not empty and 0 for empty. If the
|
||
|
device can determine how full the tray is, the device
|
||
|
returns a percentage full from 0% to 100%
|
||
|
Additional information:
|
||
|
LaserJet 4V can only detect empty/not empty tray.
|
||
|
It returns -1 for not empty and 0 for empty."
|
||
|
::= { intray2 2 }
|
||
|
|
||
|
|
||
|
tray2-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the device specific name for tray 2."
|
||
|
::= { intray2 3 }
|
||
|
|
||
|
tray2-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this input tray."
|
||
|
::= { intray2 12 }
|
||
|
|
||
|
tray2-fuser-temperature OBJECT-TYPE
|
||
|
SYNTAX INTEGER(-1..1)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The fuser temperature to be used when printing media
|
||
|
from Tray 2. The value zero is the default temperature.
|
||
|
Values less than zero are progressively lower and values
|
||
|
greater than zero are progressively higher. The range
|
||
|
of values supported is device specific.
|
||
|
Additional information:
|
||
|
See TRAY1-FUSER-TEMPERATURE."
|
||
|
::= { intray2 13 }
|
||
|
|
||
|
|
||
|
tray3-media-size-loaded OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUSExecutive(1),
|
||
|
eUSLetter(2),
|
||
|
eUSLegal(3),
|
||
|
eLedger(11),
|
||
|
eISOandJISA4(26),
|
||
|
eISOandJISA3(27),
|
||
|
eJISB5(45),
|
||
|
eJISB4(46),
|
||
|
eCustom(101),
|
||
|
eUnknownMediaSize(32767)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the media size that is currently configured in
|
||
|
tray #3. Complete list of supported media sizes along
|
||
|
with their dimensions are listed in the ''Media Size
|
||
|
Table'' near the end of this document.
|
||
|
Additional information:
|
||
|
If the tray drawer is open, a get on this object
|
||
|
will cause a status of
|
||
|
<genErr> to be
|
||
|
returned. If the tray is empty, the size that the
|
||
|
tray is configured for will be returned."
|
||
|
::= { intray3 1 }
|
||
|
|
||
|
tray3-media-available OBJECT-TYPE
|
||
|
SYNTAX INTEGER(-1..100)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns a number that indicates how full the input tray
|
||
|
is. If the device can only detect empty / not empty the
|
||
|
device returns -1 for not empty and 0 for empty. If the
|
||
|
device can determine how full the tray is, the device
|
||
|
returns a percentage full from 0% to 100%
|
||
|
Additional information:
|
||
|
LaserJet 4V can only detect empty/not empty tray.
|
||
|
It returns -1 for not empty and 0 for empty.
|
||
|
This object is only supported if a LC is installed.
|
||
|
Returns <noSuchName> status
|
||
|
if attempting to perform a Get on this OID with
|
||
|
no LC installed.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to perform a Set, EnableTrap, or
|
||
|
DisableTrap on this OID with no LC installed."
|
||
|
::= { intray3 2 }
|
||
|
|
||
|
|
||
|
tray3-name OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the device specific name for tray 3.
|
||
|
Additional information:
|
||
|
This object is only supported if a LC is
|
||
|
installed.
|
||
|
Returns <noSuchName> status if
|
||
|
attempting to perform a Get on this OID with no LC
|
||
|
installed.
|
||
|
Returns <noSuchName>
|
||
|
status if attempting to perform a Set, EnableTrap, or
|
||
|
DisableTrap on this OID with no LC installed."
|
||
|
::= { intray3 3 }
|
||
|
|
||
|
tray3-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this input tray."
|
||
|
::= { intray3 12 }
|
||
|
|
||
|
tray3-fuser-temperature OBJECT-TYPE
|
||
|
SYNTAX INTEGER(-1..1)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The fuser temperature to be used when printing media
|
||
|
from Tray 3. The value zero is the default temperature.
|
||
|
Values less than zero are progressively lower and values
|
||
|
greater than zero are progressively higher. The range
|
||
|
of values supported is device specific.
|
||
|
Additional information:
|
||
|
See TRAY1-FUSER-TEMPERATURE."
|
||
|
::= { intray3 13 }
|
||
|
|
||
|
tray4-media-size-loaded OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUSLetter(2),
|
||
|
eUSLegal(3),
|
||
|
eLedger(11),
|
||
|
eISOandJISA3(27),
|
||
|
eISOandJISA4(26),
|
||
|
eJISB4(46)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the media size that is currently configured in
|
||
|
tray #4. Complete list of supported media sizes along
|
||
|
with their dimensions are listed in the ''Media Size
|
||
|
Table'' near the end of this document.
|
||
|
Additional information:
|
||
|
The Media Size Table does not exist in this document.
|
||
|
Attempting to access this object when the tray is not installed
|
||
|
will result in an ErrorUnknownObjectIdentifier response from
|
||
|
the printer."
|
||
|
::= { intray4 1 }
|
||
|
|
||
|
tray4-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this input tray."
|
||
|
::= { intray4 12 }
|
||
|
|
||
|
|
||
|
tray5-media-size-loaded OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUSExecutive(1),
|
||
|
eUSLetter(2),
|
||
|
eUSLegal(3),
|
||
|
eJISB5(45),
|
||
|
eISOandJISA4(26),
|
||
|
eCustom(101),
|
||
|
eUnknownMediaSize(32767)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the media size that is currently configured in
|
||
|
tray #5. Complete list of supported media sizes along
|
||
|
with their dimensions are listed in the ''Media Size
|
||
|
Table'' near the end of this document.
|
||
|
Additional information:
|
||
|
If the tray drawer is open, a get on this object
|
||
|
will cause a status of
|
||
|
<genErr> to be
|
||
|
returned. If the tray is empty, the size that the
|
||
|
tray is configured for will be returned."
|
||
|
::= { intray5 1 }
|
||
|
|
||
|
|
||
|
tray5-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this input tray."
|
||
|
::= { intray5 12 }
|
||
|
|
||
|
tray6-media-size-loaded OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUSLetter(2),
|
||
|
eUSLegal(3),
|
||
|
eISOandJISA4(26),
|
||
|
eJISB4(46)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the media size that is currently configured in
|
||
|
tray #5. Complete list of supported media sizes along
|
||
|
with their dimensions are listed in the ''Media Size
|
||
|
Table'' near the end of this document.
|
||
|
Additional information:
|
||
|
If the tray drawer is open, a get on this object
|
||
|
will cause a status of
|
||
|
<genErr> to be
|
||
|
returned. If the tray is empty, the size that the
|
||
|
tray is configured for will be returned"
|
||
|
::= { intray6 1 }
|
||
|
|
||
|
|
||
|
tray6-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this input tray.
|
||
|
Additional information:
|
||
|
The internal trays belong to device 0 (base engine), the
|
||
|
envelope feeder is considered to be device 1
|
||
|
and the external input devices can number
|
||
|
between 2 and 6 depending on individual user
|
||
|
configurations."
|
||
|
::= { intray6 12 }
|
||
|
|
||
|
|
||
|
tray7-media-size-loaded OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eUSLetter(2),
|
||
|
eUSLegal(3),
|
||
|
eLedger(11),
|
||
|
eISOandJISA4(26),
|
||
|
eISOandJISA3(27),
|
||
|
eJISB4(46)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns the media size that is currently configured in
|
||
|
tray #5. Complete list of supported media sizes along
|
||
|
with their dimensions are listed in the ''Media Size
|
||
|
Table'' near the end of this document.
|
||
|
Additional information:
|
||
|
If the tray drawer is open, a get on this object
|
||
|
will cause a status of
|
||
|
<genErr> to be
|
||
|
returned. If the tray is empty, the size that the
|
||
|
tray is configured for will be returned"
|
||
|
::= { intray7 1 }
|
||
|
|
||
|
|
||
|
tray7-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this input tray.
|
||
|
Additional information:
|
||
|
The internal trays belong to device 0 (base engine), the
|
||
|
envelope feeder is considered to be device 1
|
||
|
and the external input devices can number
|
||
|
between 2 and 6 depending on individual user
|
||
|
configurations.
|
||
|
NOTE: only TRAY6 and TRAY7 are listed here
|
||
|
because HP does not make a device with more than
|
||
|
two trays, but the Specification requires
|
||
|
support of up to 10 external trays. Therefore the
|
||
|
objects for TRAY8-PHD ... TRAY15-PHD will exist if
|
||
|
that many trays exist."
|
||
|
::= { intray7 12 }
|
||
|
|
||
|
|
||
|
|
||
|
outbin3-override-mode OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the device behavior when this output bin
|
||
|
condition causes printing to stop.
|
||
|
cCancelJob - The device cancels the job.
|
||
|
cOutbinFullOverride - The device sends subsequent
|
||
|
media to the overflow bin.
|
||
|
cOutbinAttentionOverride - The device ignores the
|
||
|
attention condition and continues printing.
|
||
|
cBinderAttentionOverride - The device ignores the
|
||
|
binder attention condition and continues printing.
|
||
|
Additional information:
|
||
|
If cCancelJob is set, the current print job will
|
||
|
be cancelled regardless of other item settings.
|
||
|
This object describes the action that is performed
|
||
|
when the JOB-OUTPUT-AUTO-CONTINUE-TIMEOUT expires.
|
||
|
The action performed by the CONTINUE object being set
|
||
|
to eInitiateAction or the GO key being pressed on the
|
||
|
control panel may cause different actions. See the
|
||
|
CONTINUE object
|
||
|
description for information on the actions that
|
||
|
occur for those conditions.
|
||
|
NOTE: Because HP is marketing a device with a max of
|
||
|
16 bins the OUTBIN-OVERRIDE-MODE objects are 3-18 but
|
||
|
the external device specification requires support of
|
||
|
up to 315 output bins. Therefore if these bins exist
|
||
|
above 16, then the coresponding objects will also exist
|
||
|
OUTBIN19-OVERRIDE-MODE through OUTBIN317-OVERRIDE-MODE
|
||
|
The data for this object is stored in NVRAM."
|
||
|
::= { outbin3 9 }
|
||
|
|
||
|
|
||
|
outbin3-maximum-binding OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum number of sheets of 20 pound paper that can
|
||
|
be bound by the binding device that serves this output
|
||
|
bin. If a job exceeds this number and the job has
|
||
|
requested binding, cBindingError will be set in NOT-
|
||
|
READY-DESTINATION-PRINT-ENGINE.
|
||
|
Additional information:
|
||
|
This is a read only object that returns the number of
|
||
|
20# pages that this bin can bind(i.e. staple). This
|
||
|
number is used by the host applications to prevent
|
||
|
jobs that exceed this amount from being sent to this
|
||
|
bin. If this bin does not have a finishing function
|
||
|
like stapling where this object is necessary the
|
||
|
object will return <badValue>.
|
||
|
NOTE: Because HP is marketing a device with a max of
|
||
|
16 bins the OUTBIN-MAXIMUM-BINDING objects are 3-18 but
|
||
|
the external device specification requires support of
|
||
|
up to 315 output bins. Therefore if these bins exist
|
||
|
above 16, then the coresponding objects will also exist
|
||
|
OUTBIN19-MAXIMUM-BINDING ... OUTBIN317-MAXIMUM-BINDING"
|
||
|
::= { outbin3 10 }
|
||
|
|
||
|
|
||
|
outbin3-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this output bin.
|
||
|
Additional information:
|
||
|
This object will return the the device number that
|
||
|
contains this output bin. The envelope feed is
|
||
|
considered PHD1 thus this object will return
|
||
|
2-6 depending on where in the device chain the bin
|
||
|
exists.
|
||
|
NOTE: Because HP is marketing a device with a max of
|
||
|
16 bins the OUTBIN-OVERRIDE-MODE objects are 3-18 but
|
||
|
the external device specification requires support of
|
||
|
up to 315 output bins. Therefore if these bins exist
|
||
|
above 16, then the coresponding objects will also exist
|
||
|
OUTBIN19-PHD through OUTBIN317-PHD"
|
||
|
::= { outbin3 11 }
|
||
|
|
||
|
|
||
|
outbin3-error-info OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..65535))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A device specific description of the last error
|
||
|
encountered for output bin 3. Each POS should document
|
||
|
the meaning of all supported error information.
|
||
|
Additional information:
|
||
|
This is a description of the current error state of a
|
||
|
finishing device. (ie stapler). If the bin does not
|
||
|
support any finishing capabilities then the object
|
||
|
will return <badValue>.
|
||
|
The possible return values are as follows:
|
||
|
Byte1, Byte2, and Byte3 should be 0x00. as they are
|
||
|
reserved for future use.
|
||
|
Byte4 is a bit field that can be interpreted as
|
||
|
follows:
|
||
|
bit 0 -- unused
|
||
|
bit 1 -- eBinderOut Out of staples
|
||
|
bit 2 -- eBinderLimit Too many pages to finish
|
||
|
bit 3 -- eBinderJam Staple jammed in stapler
|
||
|
bit 4 -- eBinderAlign Pages aren't aligned correctly
|
||
|
to finish.
|
||
|
bit 5 -- unused
|
||
|
bit 6 -- unused
|
||
|
bit 7 -- unused
|
||
|
|
||
|
NOTE: Because HP is marketing a device with a max of
|
||
|
16 bins the OUTBIN-MAXIMUM-BINDING objects are 3-18 but
|
||
|
the external device specification requires support of
|
||
|
up to 315 output bins. Therefore if these bins exist
|
||
|
above 16, then the coresponding objects will also exist
|
||
|
OUTBIN19-MAXIMUM-BINDING ... OUTBIN317-MAXIMUM-BINDING"
|
||
|
::= { outbin3 12 }
|
||
|
|
||
|
outbin4-override-mode OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the device behavior when this output bin
|
||
|
condition causes printing to stop.
|
||
|
cCancelJob - The device cancels the job.
|
||
|
cOutbinFullOverride - The device sends subsequent
|
||
|
media to the overflow bin.
|
||
|
cOutbinAttentionOverride - The device ignores the
|
||
|
attention condition and continues printing.
|
||
|
cBinderAttentionOverride - The device ignores the
|
||
|
binder attention condition and continues printing.
|
||
|
Additional information:
|
||
|
See OUTBIN3-OVERRIDE-MODE."
|
||
|
::= { outbin4 9 }
|
||
|
|
||
|
|
||
|
outbin4-maximum-binding OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum number of sheets of 20 pound paper that can
|
||
|
be bound by the binding device that serves this output
|
||
|
bin. If a job exceeds this number and the job has
|
||
|
requested binding, cBindingError will be set in NOT-
|
||
|
READY-DESTINATION-PRINT-ENGINE.
|
||
|
Additional information:
|
||
|
See OUTBIN3-MAXIMUM-BINDING."
|
||
|
::= { outbin4 10 }
|
||
|
|
||
|
|
||
|
outbin4-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this output bin.
|
||
|
Additional information:
|
||
|
See OUTBIN3-PHD."
|
||
|
::= { outbin4 11 }
|
||
|
|
||
|
outbin5-override-mode OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the device behavior when this output bin
|
||
|
condition causes printing to stop.
|
||
|
cCancelJob - The device cancels the job.
|
||
|
cOutbinFullOverride - The device sends subsequent
|
||
|
media to the overflow bin.
|
||
|
cOutbinAttentionOverride - The device ignores the
|
||
|
attention condition and continues printing.
|
||
|
cBinderAttentionOverride - The device ignores the
|
||
|
binder attention condition and continues printing.
|
||
|
Additional information:
|
||
|
See OUTBIN3-OVERRIDE-MODE."
|
||
|
::= { outbin5 9 }
|
||
|
|
||
|
|
||
|
outbin5-maximum-binding OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum number of sheets of 20 pound paper that can
|
||
|
be bound by the binding device that serves this output
|
||
|
bin. If a job exceeds this number and the job has
|
||
|
requested binding, cBindingError will be set in NOT-
|
||
|
READY-DESTINATION-PRINT-ENGINE.
|
||
|
Additional information:
|
||
|
See OUTBIN3-MAXIMUM-BINDING."
|
||
|
::= { outbin5 10 }
|
||
|
|
||
|
|
||
|
outbin5-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this output bin.
|
||
|
Additional information:
|
||
|
See OUTBIN3-PHD."
|
||
|
::= { outbin5 11 }
|
||
|
|
||
|
|
||
|
outbin6-override-mode OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the device behavior when this output bin
|
||
|
condition causes printing to stop.
|
||
|
cCancelJob - The device cancels the job.
|
||
|
cOutbinFullOverride - The device sends subsequent
|
||
|
media to the overflow bin.
|
||
|
cOutbinAttentionOverride - The device ignores the
|
||
|
attention condition and continues printing.
|
||
|
cBinderAttentionOverride - The device ignores the
|
||
|
binder attention condition and continues printing.
|
||
|
Additional information:
|
||
|
See OUTBIN3-OVERRIDE-MODE."
|
||
|
::= { outbin6 9 }
|
||
|
|
||
|
|
||
|
outbin6-maximum-binding OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum number of sheets of 20 pound paper that can
|
||
|
be bound by the binding device that serves this output
|
||
|
bin. If a job exceeds this number and the job has
|
||
|
requested binding, cBindingError will be set in NOT-
|
||
|
READY-DESTINATION-PRINT-ENGINE.
|
||
|
Additional information:
|
||
|
See OUTBIN3-MAXIMUM-BINDING."
|
||
|
::= { outbin6 10 }
|
||
|
|
||
|
|
||
|
outbin6-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this output bin.
|
||
|
Additional information:
|
||
|
See OUTBIN3-PHD."
|
||
|
::= { outbin6 11 }
|
||
|
|
||
|
|
||
|
outbin7-override-mode OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the device behavior when this output bin
|
||
|
condition causes printing to stop.
|
||
|
cCancelJob - The device cancels the job.
|
||
|
cOutbinFullOverride - The device sends subsequent
|
||
|
media to the overflow bin.
|
||
|
cOutbinAttentionOverride - The device ignores the
|
||
|
attention condition and continues printing.
|
||
|
cBinderAttentionOverride - The device ignores the
|
||
|
binder attention condition and continues printing.
|
||
|
Additional information:
|
||
|
See OUTBIN3-OVERRIDE-MODE."
|
||
|
::= { outbin7 9 }
|
||
|
|
||
|
|
||
|
outbin7-maximum-binding OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum number of sheets of 20 pound paper that can
|
||
|
be bound by the binding device that serves this output
|
||
|
bin. If a job exceeds this number and the job has
|
||
|
requested binding, cBindingError will be set in NOT-
|
||
|
READY-DESTINATION-PRINT-ENGINE.
|
||
|
Additional information:
|
||
|
See OUTBIN3-MAXIMUM-BINDING."
|
||
|
::= { outbin7 10 }
|
||
|
|
||
|
|
||
|
outbin7-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this output bin.
|
||
|
Additional information:
|
||
|
See OUTBIN3-PHD."
|
||
|
::= { outbin7 11 }
|
||
|
|
||
|
|
||
|
outbin8-override-mode OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the device behavior when this output bin
|
||
|
condition causes printing to stop.
|
||
|
cCancelJob - The device cancels the job.
|
||
|
cOutbinFullOverride - The device sends subsequent
|
||
|
media to the overflow bin.
|
||
|
cOutbinAttentionOverride - The device ignores the
|
||
|
attention condition and continues printing.
|
||
|
cBinderAttentionOverride - The device ignores the
|
||
|
binder attention condition and continues printing.
|
||
|
Additional information:
|
||
|
See OUTBIN3-OVERRIDE-MODE."
|
||
|
::= { outbin8 9 }
|
||
|
|
||
|
|
||
|
outbin8-maximum-binding OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum number of sheets of 20 pound paper that can
|
||
|
be bound by the binding device that serves this output
|
||
|
bin. If a job exceeds this number and the job has
|
||
|
requested binding, cBindingError will be set in NOT-
|
||
|
READY-DESTINATION-PRINT-ENGINE.
|
||
|
Additional information:
|
||
|
See OUTBIN3-MAXIMUM-BINDING."
|
||
|
::= { outbin8 10 }
|
||
|
|
||
|
|
||
|
outbin8-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this output bin.
|
||
|
Additional information:
|
||
|
See OUTBIN3-PHD."
|
||
|
::= { outbin8 11 }
|
||
|
|
||
|
|
||
|
outbin9-override-mode OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the device behavior when this output bin
|
||
|
condition causes printing to stop.
|
||
|
cCancelJob - The device cancels the job.
|
||
|
cOutbinFullOverride - The device sends subsequent
|
||
|
media to the overflow bin.
|
||
|
cOutbinAttentionOverride - The device ignores the
|
||
|
attention condition and continues printing.
|
||
|
cBinderAttentionOverride - The device ignores the
|
||
|
binder attention condition and continues printing.
|
||
|
Additional information:
|
||
|
See OUTBIN3-OVERRIDE-MODE."
|
||
|
::= { outbin9 9 }
|
||
|
|
||
|
|
||
|
outbin9-maximum-binding OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum number of sheets of 20 pound paper that can
|
||
|
be bound by the binding device that serves this output
|
||
|
bin. If a job exceeds this number and the job has
|
||
|
requested binding, cBindingError will be set in NOT-
|
||
|
READY-DESTINATION-PRINT-ENGINE.
|
||
|
Additional information:
|
||
|
See OUTBIN3-MAXIMUM-BINDING."
|
||
|
::= { outbin9 10 }
|
||
|
|
||
|
|
||
|
outbin9-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this output bin.
|
||
|
Additional information:
|
||
|
See OUTBIN3-PHD."
|
||
|
::= { outbin9 11 }
|
||
|
|
||
|
outbin9-error-info OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..65535))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A device specific description of the last error
|
||
|
encountered for output bin 9. Each POS should document
|
||
|
the meaning of all supported error information.
|
||
|
Additional information:
|
||
|
This is a description of the current error state of a
|
||
|
finishing device. (ie stapler). If the bin does not
|
||
|
support any finishing capabilities then the object
|
||
|
will return <badValue>.
|
||
|
The possible return values are as follows:
|
||
|
Byte1, Byte2, and Byte3 should be 0x00. as they are
|
||
|
reserved for future use.
|
||
|
Byte4 is a bit field that can be interpreted as
|
||
|
follows:
|
||
|
bit 0 -- unused
|
||
|
bit 1 -- eBinderOut Out of staples
|
||
|
bit 2 -- eBinderLimit Too many pages to finish
|
||
|
bit 3 -- eBinderJam Staple jammed in stapler
|
||
|
bit 4 -- eBinderAlign Pages aren't aligned correctly
|
||
|
to finish.
|
||
|
bit 5 -- unused
|
||
|
bit 6 -- unused
|
||
|
bit 7 -- unused
|
||
|
|
||
|
OUTBIN3 is the topmost bin on the output device. This bin
|
||
|
replaces the left output bin on the base printer. OUTBIN4
|
||
|
through OUTBIN8 are the additional 5 regular bins supplied
|
||
|
by the MBM5S device. OUTBIN9 is the stapler unit and is
|
||
|
the lowest bin in the device.
|
||
|
NOTE: Because HP is marketing a device with a max of
|
||
|
7 bins (MBM5S) the OUTBINn-ERROR-INFO objects are
|
||
|
3-9 but the external device specification requires
|
||
|
support of up to 315 output bins. Therefore if these
|
||
|
bins exist above 7, then the coresponding objects will
|
||
|
also exist OUTBIN10-ERROR-INFO through OUTBIN317-ERROR-INFO."
|
||
|
::= { outbin9 12 }
|
||
|
|
||
|
outbin10-override-mode OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the device behavior when this output bin
|
||
|
condition causes printing to stop.
|
||
|
cCancelJob - The device cancels the job.
|
||
|
cOutbinFullOverride - The device sends subsequent
|
||
|
media to the overflow bin.
|
||
|
cOutbinAttentionOverride - The device ignores the
|
||
|
attention condition and continues printing.
|
||
|
cBinderAttentionOverride - The device ignores the
|
||
|
binder attention condition and continues printing.
|
||
|
Additional information:
|
||
|
See OUTBIN3-OVERRIDE-MODE."
|
||
|
::= { outbin10 9 }
|
||
|
|
||
|
|
||
|
outbin10-maximum-binding OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum number of sheets of 20 pound paper that can
|
||
|
be bound by the binding device that serves this output
|
||
|
bin. If a job exceeds this number and the job has
|
||
|
requested binding, cBindingError will be set in NOT-
|
||
|
READY-DESTINATION-PRINT-ENGINE.
|
||
|
Additional information:
|
||
|
See OUTBIN3-MAXIMUM-BINDING."
|
||
|
::= { outbin10 10 }
|
||
|
|
||
|
|
||
|
outbin10-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this output bin.
|
||
|
Additional information:
|
||
|
See OUTBIN3-PHD."
|
||
|
::= { outbin10 11 }
|
||
|
|
||
|
|
||
|
outbin11-override-mode OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the device behavior when this output bin
|
||
|
condition causes printing to stop.
|
||
|
cCancelJob - The device cancels the job.
|
||
|
cOutbinFullOverride - The device sends subsequent
|
||
|
media to the overflow bin.
|
||
|
cOutbinAttentionOverride - The device ignores the
|
||
|
attention condition and continues printing.
|
||
|
cBinderAttentionOverride - The device ignores the
|
||
|
binder attention condition and continues printing.
|
||
|
Additional information:
|
||
|
See OUTBIN3-OVERRIDE-MODE."
|
||
|
::= { outbin11 9 }
|
||
|
|
||
|
|
||
|
outbin11-maximum-binding OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum number of sheets of 20 pound paper that can
|
||
|
be bound by the binding device that serves this output
|
||
|
bin. If a job exceeds this number and the job has
|
||
|
requested binding, cBindingError will be set in NOT-
|
||
|
READY-DESTINATION-PRINT-ENGINE.
|
||
|
Additional information:
|
||
|
See OUTBIN3-MAXIMUM-BINDING."
|
||
|
::= { outbin11 10 }
|
||
|
|
||
|
|
||
|
outbin11-phd OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Provides the number of the Paper Handling Device that
|
||
|
contains this output bin.
|
||
|
Additional information:
|
||
|
See OUTBIN3-PHD."
|
||
|
::= { outbin11 11 }
|
||
|
|
||
|
|
||
|
media-names-available OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of this object controls which of the MEDIAx-
|
||
|
NAME objects are supported. If a bit is set to zero,
|
||
|
then attempting to get or set the corresponding MEDIAx-
|
||
|
NAME objects will return
|
||
|
<noSuchName>.
|
||
|
Additional information:
|
||
|
Setting a bit to one will cause the corresponding
|
||
|
MEDIAn- objects to be available (attempting to access
|
||
|
an unavailable object will return <noSuchName>).
|
||
|
MEDIA1- objects are always present in LaserJet 4000 Series, as this is the default
|
||
|
media. If this object is set to a value that does not include
|
||
|
cMediaName1Available, that bit will be set and a status of
|
||
|
<noError> will be returned.
|
||
|
cMediaName12Available cannot be changed on LaserJet 4000 Series, as MediaName12
|
||
|
is not a supported Media Name for that product. Attempts to set
|
||
|
cMediaName12Available will cause <badValue>
|
||
|
to be returned."
|
||
|
::= { settings-print-media 1 }
|
||
|
|
||
|
|
||
|
media4-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media4 4 }
|
||
|
|
||
|
|
||
|
media6-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media6 4 }
|
||
|
|
||
|
|
||
|
media10-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media10 4 }
|
||
|
|
||
|
|
||
|
media11-engine-media-mode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The engine processing characteristics that are to be
|
||
|
applied to this media. The processing characteristics
|
||
|
are device specific.
|
||
|
Additional information:
|
||
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
|
::= { media11 4 }
|
||
|
|
||
|
engine-media-mode1-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of sheets printed using this media mode. The
|
||
|
device POS should state whether this value is lost
|
||
|
across a power cycle or is kept in permanent storage.
|
||
|
Additional information:
|
||
|
The value of this object is persistent across a power cycle.
|
||
|
Engine media mode 1 is normal fusing.
|
||
|
Engine media mode 2 is transparency fusing.
|
||
|
Engine media mode 3 is glossy fusing.
|
||
|
Enigne media mode 4 is heavy media fusing.
|
||
|
Engine media mode 5 is envelope fusing."
|
||
|
::= { media-mode1 2 }
|
||
|
|
||
|
|
||
|
engine-media-mode2-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of sheets printed using this media mode. The
|
||
|
device POS should state whether this value is lost
|
||
|
across a power cycle or is kept in permanent storage.
|
||
|
Additional information:
|
||
|
The value of this object is persistent across a power cycle.
|
||
|
Engine media mode 1 is normal fusing.
|
||
|
Engine media mode 2 is transparency fusing.
|
||
|
Engine media mode 3 is glossy fusing.
|
||
|
Enigne media mode 4 is heavy media fusing.
|
||
|
Engine media mode 5 is envelope fusing."
|
||
|
::= { media-mode2 2 }
|
||
|
|
||
|
|
||
|
engine-media-mode3-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of sheets printed using this media mode. The
|
||
|
device POS should state whether this value is lost
|
||
|
across a power cycle or is kept in permanent storage.
|
||
|
Additional information:
|
||
|
The value of this object is persistent across a power cycle.
|
||
|
Engine media mode 1 is normal fusing.
|
||
|
Engine media mode 2 is transparency fusing.
|
||
|
Engine media mode 3 is glossy fusing.
|
||
|
Enigne media mode 4 is heavy media fusing.
|
||
|
Engine media mode 5 is envelope fusing."
|
||
|
::= { media-mode3 2 }
|
||
|
|
||
|
|
||
|
engine-media-mode4-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of sheets printed using this media mode. The
|
||
|
device POS should state whether this value is lost
|
||
|
across a power cycle or is kept in permanent storage.
|
||
|
Additional information:
|
||
|
The value of this object is persistent across a power cycle.
|
||
|
Engine media mode 1 is normal fusing.
|
||
|
Engine media mode 2 is transparency fusing.
|
||
|
Engine media mode 3 is glossy fusing.
|
||
|
Enigne media mode 4 is heavy media fusing.
|
||
|
Engine media mode 5 is envelope fusing."
|
||
|
::= { media-mode4 2 }
|
||
|
|
||
|
|
||
|
engine-media-mode5-page-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of sheets printed using this media mode. The
|
||
|
device POS should state whether this value is lost
|
||
|
across a power cycle or is kept in permanent storage.
|
||
|
Additional information:
|
||
|
The value of this object is persistent across a power cycle.
|
||
|
Engine media mode 1 is normal fusing.
|
||
|
Engine media mode 2 is transparency fusing.
|
||
|
Engine media mode 3 is glossy fusing.
|
||
|
Enigne media mode 4 is heavy media fusing.
|
||
|
Engine media mode 5 is envelope fusing."
|
||
|
::= { media-mode5 2 }
|
||
|
|
||
|
media-size-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of impressions printed on sheets of this
|
||
|
media size. The device POS should state whether this
|
||
|
value is lost across a power cycle or is kept in
|
||
|
permanent storage.
|
||
|
Additional information:
|
||
|
The value of this object is persistent across a power cycle.
|
||
|
|
||
|
The index for these objects, the last number of the OID, uniquely identifies the paper size. This value
|
||
|
corresponds to the page sizes listed below. These values are also documented in the PCL Implementor's Guide
|
||
|
and the PML Master MIB.
|
||
|
|
||
|
1 US-Executive
|
||
|
2 US-Letter
|
||
|
3 US-Legal
|
||
|
25 ISO and JIS A5
|
||
|
26 ISO and JIS A4
|
||
|
45 JIS B5
|
||
|
80 LaserJet 4500
|
||
|
81 Commercal-10
|
||
|
90 International DL
|
||
|
91 International C5
|
||
|
100 International B5
|
||
|
101 Custom"
|
||
|
::= { media-size 1 }
|
||
|
|
||
|
media-size-west-edge-first-side-offset OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the number of 300 dpi dots by which the
|
||
|
image is shifted relative to the west edge of the medium
|
||
|
(see NORTH-EDGE-OFFSET). The adjustment is for the
|
||
|
first printed side of the medium only. A positive value
|
||
|
moves the image away from the west edge of the medium.
|
||
|
A negative value moves the image closer to the west edge
|
||
|
of the medium. The value 0 will return the image to its
|
||
|
factory default position.
|
||
|
Additional information:
|
||
|
Returns or sets the number of 300 dpi dots by which the
|
||
|
image is shifted relative to the west edge of the medium
|
||
|
(see NORTH-EDGE-OFFSET). The adjustment is for the
|
||
|
first printed side of the medium only. A positive value
|
||
|
moves the image away from the west edge of the medium.
|
||
|
A negative value moves the image closer to the west edge
|
||
|
of the medium. The value 0 will return the image to its
|
||
|
factory default position. The values in the sub array index
|
||
|
are from the media size table in the hpmib.
|
||
|
The data for this object is stored in NVRAM."
|
||
|
::= { media-size 2 }
|
||
|
|
||
|
|
||
|
media-size-west-edge-second-side-offset OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Returns or sets the number of 300 dpi dots by which the
|
||
|
image is shifted relative to the west edge of the medium
|
||
|
(see NORTH-EDGE-OFFSET). The adjustment is for the
|
||
|
second printed side of the medium only. A positive
|
||
|
value moves the image away from the west edge of the
|
||
|
medium. A negative value moves the image closer to the
|
||
|
west edge of the medium. The value 0 will return the
|
||
|
image to its factory default position.
|
||
|
Additional information:
|
||
|
Returns or sets the number of 300 dpi dots by which the
|
||
|
image is shifted relative to the west edge of the medium
|
||
|
(see NORTH-EDGE-OFFSET). The adjustment is for the
|
||
|
second printed side of the medium only. A positive value
|
||
|
moves the image away from the west edge of the medium.
|
||
|
A negative value moves the image closer to the west edge
|
||
|
of the medium. The value 0 will return the image to its
|
||
|
factory default position. The values in the sub array index
|
||
|
are from the media size table in the hpmib.
|
||
|
The data for this object is stored in NVRAM."
|
||
|
::= { media-size 3 }
|
||
|
|
||
|
|
||
|
prtoutputdefaultindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of prtOutputIndex corresponding to the default
|
||
|
output sub-unit; that is, this object selects the default
|
||
|
output destination.
|
||
|
This value shall be -1 if there is no default output subunit specified
|
||
|
for the printer as a whole. In this case, the actual default
|
||
|
output subunit may be specified by means outside the scope of this
|
||
|
MIB, such as by each interpreter in a printer with multiple
|
||
|
interpreters.
|
||
|
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4050 Series (LaserJet 4050) has two output bins in the
|
||
|
base product: a face-up bin on the back of the engine and a
|
||
|
face-down bin on the top of the engine. These bins are not
|
||
|
firmware-selectable; instead, paper is diverted to the face-down
|
||
|
bin only if the face-up bin is physically closed. Therefore,
|
||
|
these bins are considered together as the 'standard' bin. However,
|
||
|
if an HCO is attached to the engine, users will be able to select
|
||
|
between an HCO bin and the 'standard' bin, which may be either the
|
||
|
face-up or face-down bin, depending upon whether the face-up bin
|
||
|
is open. With external output bins attached, the value of this
|
||
|
object will be settable from the control panel and by the PJL
|
||
|
OUTBIN variable."
|
||
|
::= { prtGeneralEntry 7 }
|
||
|
|
||
|
|
||
|
prtinputtype OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePunknown(2),
|
||
|
ePsheetFeedAutoRemovableTray(3),
|
||
|
ePsheetFeedAutoNonRemovableTray(4),
|
||
|
ePsheetFeedManual(5),
|
||
|
ePcontinuousRoll(6),
|
||
|
ePcontinuousFanFold(7)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The type of technology (discriminated primarily according to
|
||
|
feeder mechanism type) employed by the input sub-unit. Note,
|
||
|
the Optional Input Class provides for a descriptor field to
|
||
|
further qualify the other choice.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Tray 1 is the multi-purpose tray and is always present.
|
||
|
It supports both sheets and envelopes. Its type is
|
||
|
ePsheetFeedAutoNonRemovableTray.
|
||
|
Tray 2 is a removable tray that comes standard
|
||
|
with the printer, although it is usually not removed
|
||
|
from the printer. It is of type
|
||
|
ePsheetFeedAutoRemovableTray.
|
||
|
Tray 3 is either a 250-sheet standard tray in the
|
||
|
2x250 base engine configuration or a 500-sheet optional tray
|
||
|
in the 1x500 base engine configuration. (The optional
|
||
|
tray is only recognized if it's installed before the
|
||
|
printer is powered on.) It is of type
|
||
|
ePsheetFeedAutoRemovableTray.
|
||
|
The 4th tray in this array is the envelope feeder. It
|
||
|
can be detected even when it is installed while the
|
||
|
printer is powered on.
|
||
|
Tray 5 is a 500-sheet optional tray that cannot be
|
||
|
installed while the printer is powered on. It is of type
|
||
|
ePsheetFeedAutoRemovableTray."
|
||
|
::= { prtInputEntry 2 }
|
||
|
|
||
|
|
||
|
prtinputdimunit OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePtenThousandthsOfInches(3),
|
||
|
ePmicrometers(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The unit of measurement for use calculating and relaying
|
||
|
dimensional values for this input sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Following is a table of paper sizes and dimensions
|
||
|
for each paper size supported by LaserJet 4000 Series:
|
||
|
|
||
|
Size Inches (ten-thousandths) Millimeters
|
||
|
--------------- ------------------------ -----------
|
||
|
eUSExecutive 72500 x 105000 184150 x 266700
|
||
|
eUSLetter 85000 x 110000 215900 x 279400
|
||
|
eUSLegal 85000 x 140000 215900 x 355600
|
||
|
eISOandJISA5 58286 x 82677 148000 x 210000
|
||
|
eISOandJISA4 82677 x 116929 210000 x 297000
|
||
|
eJISB5 71654 x 101181 182000 x 257000
|
||
|
eMonarch 38750 x 75000 98425 x 190500
|
||
|
eCommercial10 41250 x 95000 104775 x 241300
|
||
|
eInternationalDL 43307 x 86614 110000 x 220000
|
||
|
eInternationalC5 63780 x 90157 162000 x 229000
|
||
|
eInternationalB5 69291 x 98425 176000 x 250000
|
||
|
eCustom 85000 x 140000 (max) 215900 x 355600 (max) "
|
||
|
::= { prtInputEntry 3 }
|
||
|
|
||
|
|
||
|
prtinputmediadimfeeddirdeclared OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object provides the value of the declared dimension, in
|
||
|
the feed direction, of the media that is (or, if empty, was or
|
||
|
will be) in this input sub-unit. The feed direction is the
|
||
|
direction in which the media is fed on this sub-unit. This
|
||
|
dimension is measured in input sub-unit dimensional units
|
||
|
(prtInputDimUnit). If this input sub-unit can reliably sense
|
||
|
this value, the value is sensed by the printer and may not be
|
||
|
changed by management requests. Otherwise, the value may be
|
||
|
changed. The value (-1) means other and specifically means
|
||
|
that this sub-unit places no restriction on this parameter.
|
||
|
The value (-2) indicates unknown.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
For trays 2, 3, and 5 (which can reliably sense this
|
||
|
value) these objects behave exactly the same as prtInputMediaDimFeedDirChosen.
|
||
|
Attempting to set the objects for tray 2, 3, or 5 will cause
|
||
|
<noSuchName> to be returned.
|
||
|
The default values assume the trays are configured for letter size paper (or COM10,
|
||
|
in the case of the envelope feeder). For tray 1, the value is the dimension for
|
||
|
the media size currently declared. For the envelope feeder (tray 4), the value is
|
||
|
the dimension for the media size currently declared.
|
||
|
Valid values are 0 to 268435455. If a value within 0.2 inches of a standard
|
||
|
size (e.g. 85001) is chosen when setting these objects, the standard size will
|
||
|
be set for the specified tray if the value of prtInputMediaDimXFeedDirDeclared
|
||
|
is also set to within 0.2 inches of the same standard size. If the value is not
|
||
|
within 0.2 inches, Custom will be chosen as the size if it is supported by the
|
||
|
specified tray, otherwise the first available standard size for the tray will
|
||
|
be selected."
|
||
|
::= { prtInputEntry 4 }
|
||
|
|
||
|
|
||
|
prtinputmediadimxfeeddirdeclared OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object provides the value of the declared dimension, in
|
||
|
the cross feed direction, of the media that is (or, if empty,
|
||
|
was or will be) in this input sub-unit. The cross feed
|
||
|
direction is ninety degrees relative to the feed direction
|
||
|
associated with this sub-unit. This dimension is measured in
|
||
|
input sub-unit dimensional units (prtInputDimUnit). If this
|
||
|
input sub-unit can reliably sense this value, the value is
|
||
|
sensed by the printer and may not be changed by management
|
||
|
requests. Otherwise, the value may be changed. The value (-1)
|
||
|
means other and specifically means that this sub-unit places
|
||
|
no restriction on this parameter. The value (-2) indicates
|
||
|
unknown.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
For trays 2, 3, and 5 (which can reliably sense this
|
||
|
value) these objects behave exactly the same as prtInputMediaDimXFeedDirChosen.
|
||
|
Attempting to set these objects for tray 2, 3, and 5 will cause
|
||
|
<noSuchName> to be returned.
|
||
|
The default values assume the trays are configured for letter size paper (or COM10,
|
||
|
in the case of the envelope feeder). For tray 1 the value is the dimension for the
|
||
|
media size currently declared.
|
||
|
Valid values are 0 to 268435455. If a value within 0.2 inches of a standard
|
||
|
size (e.g. 85001) is chosen when setting these objects, the standard size will
|
||
|
be set for the specified tray if the value of prtInputMediaDimFeedDirDeclared
|
||
|
is also set to within 0.2 inches of the same standard size. If the value is not
|
||
|
within 0.2 inches, Custom will be chosen as the size if it is supported by the
|
||
|
specified tray, otherwise the first available standard size for the tray will
|
||
|
be selected."
|
||
|
::= { prtInputEntry 5 }
|
||
|
|
||
|
|
||
|
prtinputmediadimfeeddirchosen OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The printer will act as if media of the chosen dimension (in
|
||
|
the feed direction) is present in this input source. Note
|
||
|
that this value will be used even if the input tray is empty.
|
||
|
Feed dimension measurements are taken relative to the feed
|
||
|
direction associated with that sub-unit and are in input sub-unit
|
||
|
dimensional units (MediaUnit). If the printer supports the
|
||
|
declared dimension, the granted dimension is the same as
|
||
|
the declared dimension. If not, the granted dimension is
|
||
|
set to the closest dimension that the printer supports
|
||
|
when the declared dimension is set. The value (-1) means
|
||
|
other and specifically indicates that this sub-unit
|
||
|
places no restriction on this parameter. The value (-2)
|
||
|
indicates unknown.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The objects for trays 2, 3, and 5 reflect the
|
||
|
configuration of the corresponding trays. When the tray is removed, a value
|
||
|
of -2 is returned. The default values assume the trays are configured for
|
||
|
letter size paper (or COM10, in the case of the envelope feeder). For tray 1
|
||
|
and the envelope feeder, the object returns the value of the media size for
|
||
|
which the tray is currently configured because those trays cannot sense what
|
||
|
size media they contain."
|
||
|
::= { prtInputEntry 6 }
|
||
|
|
||
|
|
||
|
prtinputmediadimxfeeddirchosen OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The printer will act as if media of the chosen dimension (in
|
||
|
the cross feed direction) is present in this input source.
|
||
|
Note that this value will be used even if the input tray is
|
||
|
empty. The cross feed direction is ninety degrees relative
|
||
|
to the feed direction associated with this sub-unit. This
|
||
|
dimension is measured in input sub-unit dimensional units
|
||
|
(MediaUnit). If the printer supports the declared
|
||
|
dimension, the granted dimension is the same as the
|
||
|
declared dimension. If not, the granted dimension is set
|
||
|
to the closest dimension that the printer supports when
|
||
|
the declared dimension is set. The value (-1) means other
|
||
|
and specifically indicates that this sub-unit places no
|
||
|
restriction on this parameter. The value (-2) indicates
|
||
|
unknown.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The objects for trays 2, 3, and 5 reflect the
|
||
|
configuration of the corresponding trays. When the tray is removed, a value
|
||
|
of -2 is returned. The default values assume the trays are configured for
|
||
|
letter size paper (or COM10, in the case of the envelope feeder). The objects
|
||
|
for tray 1 and the envelope feeder return the value of the media size for which
|
||
|
the tray is currently configured because those trays cannot sense what size media
|
||
|
they contain."
|
||
|
::= { prtInputEntry 7 }
|
||
|
|
||
|
|
||
|
prtinputcapacityunit OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePtenThousandthsOfInches(3),
|
||
|
ePmicrometers(4),
|
||
|
ePsheets(8),
|
||
|
ePfeet(16),
|
||
|
ePmeters(17)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The unit of measurement for use in calculating and relaying
|
||
|
capacity values for this input sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
A sheet is a single piece of 20 pound paper. For tray
|
||
|
4, the envelope feeder, a sheet is one envelope"
|
||
|
::= { prtInputEntry 8 }
|
||
|
|
||
|
|
||
|
prtinputmaxcapacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum capacity of the input sub-unit in input
|
||
|
sub-unit capacity units (PrtCapacityUnitTC). There is no
|
||
|
convention associated with the media itself so this value
|
||
|
reflects claimed capacity. If this input sub-unit can
|
||
|
reliably sense this value, the value is sensed by the
|
||
|
printer and may not be changed by management requests;
|
||
|
otherwise, the value may be written (by a Remote
|
||
|
Control Panel or a Management Application).
|
||
|
The value (-1) means other and specifically
|
||
|
indicates that the sub-unit places no restrictions
|
||
|
on this parameter. The value (-2) means unknown.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML TRAYn-MAXIMUM-CAPACITY. This is
|
||
|
specified assuming 20 pound paper for the paper trays."
|
||
|
::= { prtInputEntry 9 }
|
||
|
|
||
|
|
||
|
prtinputcurrentlevel OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The current capacity of the input sub-unit in input
|
||
|
sub-unit capacity units (PrtCapacityUnitTC). If this input
|
||
|
sub-unit can reliably sense this value, the value is
|
||
|
sensed by the printer and may not be changed by
|
||
|
management requests; otherwise, the value may
|
||
|
be written (by a Remote Contol Panel or a
|
||
|
Management Application). The value (-1) means other and
|
||
|
specifically indicates that the sub-unit places no
|
||
|
restrictions on this parameter. The value (-2) means unknown.
|
||
|
The value (-3) means that the printer knows that at least one
|
||
|
unit remains.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4000 Series can only detect empty/not empty for its
|
||
|
trays. It returns -3 for not empty and 0 for empty.
|
||
|
If a tray is removed, a value of -2 (unknown) will
|
||
|
be returned."
|
||
|
::= { prtInputEntry 10 }
|
||
|
|
||
|
|
||
|
prtinputstatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The current status of this input sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML STATUS-TRAY-MISSING and
|
||
|
STATUS-TRAY-EMPTY.
|
||
|
Values returned by the firmware are detailed in the
|
||
|
following table. 'Value Or'd Due To Condition' indicates
|
||
|
that the specified value will be logically or'd into the
|
||
|
value for this object when the specified Condition occurs.
|
||
|
Condition Value Or'd Due To Condition
|
||
|
----------------------- ------------------------
|
||
|
Tray Lifter Error 3
|
||
|
Tray not installed or
|
||
|
not inserted or not
|
||
|
occupied 1
|
||
|
Tray is current source tray
|
||
|
and paper is moving 6
|
||
|
Tray involved in paper mount 16 + 32
|
||
|
Value 3 or 1 is Or'd in 8
|
||
|
Tray is lifting 64 "
|
||
|
::= { prtInputEntry 11 }
|
||
|
|
||
|
|
||
|
prtinputmedianame OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A description of the media contained in this input sub-unit;
|
||
|
This description is intended for display to a human operator.
|
||
|
This description is not processed by the printer. It is used
|
||
|
to provide information not expressible in terms of the other
|
||
|
media attributes (e.g. prtInputMediaDimFeedDirChosen,
|
||
|
prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
|
||
|
prtInputMediaType). An example would be `legal tender bond
|
||
|
paper'.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML TRAYn-MEDIA-NAME.
|
||
|
If set to a string other than one contained by a MEDIAn-NAME
|
||
|
object, a status of <badValue> is returned.
|
||
|
If set to a string that is unsupported for the specified tray
|
||
|
object, a status of <badValue> is returned.
|
||
|
After Build5.0 (LaserJet 8100 Series) Cassette trays will not support
|
||
|
Transparency nor Label media types.
|
||
|
The value of this object is saved across a power cycle."
|
||
|
::= { prtInputEntry 12 }
|
||
|
|
||
|
|
||
|
prtinputname OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The name assigned to this input sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML TRAYn-NAME."
|
||
|
::= { prtInputEntry 13 }
|
||
|
|
||
|
|
||
|
prtinputvendorname OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The vendor name of this input sub-unit.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtInputEntry 14 }
|
||
|
|
||
|
|
||
|
prtinputmodel OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The model name of this input sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4000 Series does not specify a model name for Tray1 or Tray2,
|
||
|
nor for Tray 3 in the 2x250 tray configuration. However, if Tray 3
|
||
|
is installed in the 1x500 configuration, 'Optional Cassette C4124A' will
|
||
|
be returned. Tray 3, 4, and 5 objects do not exist unless those trays
|
||
|
are installed."
|
||
|
::= { prtInputEntry 15 }
|
||
|
|
||
|
|
||
|
prtinputversion OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The version of this input sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4000 Series does not specify a version number
|
||
|
for the input trays."
|
||
|
::= { prtInputEntry 16 }
|
||
|
|
||
|
|
||
|
prtinputserialnumber OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The serial number assigned to this input sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4000 Series does not specify a serial number for the
|
||
|
input trays."
|
||
|
::= { prtInputEntry 17 }
|
||
|
|
||
|
|
||
|
prtinputdescription OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A free-form text description of this input
|
||
|
sub-unit in the localization specified by
|
||
|
prtGeneralCurrentLocalization.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtInputEntry 18 }
|
||
|
|
||
|
|
||
|
prtinputsecurity OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePon(3),
|
||
|
ePoff(4),
|
||
|
ePnotPresent(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if this input sub-unit has some security
|
||
|
associated with it.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
No security mechanism provided."
|
||
|
::= { prtInputEntry 19 }
|
||
|
|
||
|
|
||
|
prtinputmedialoadtimeout OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"When the printer is not able to print due to a subunit
|
||
|
being empty or the requested media must be manually loaded, the
|
||
|
printer will wait for the duration (in seconds) specified by this
|
||
|
object. Upon expiration of the timeout, the printer will take the
|
||
|
action specified by prtInputNextIndex.
|
||
|
The event which causes the printer to enter the waiting state is
|
||
|
product specific. If the printer is not waiting for manually fed
|
||
|
media, it may switch from an empty subunit to a different subunit
|
||
|
without waiting for the timeout to expire.
|
||
|
A value of (-1) implies 'other' or 'infinite' which translates to
|
||
|
'wait forever'. The action which causes printing to continue is
|
||
|
product specific. A value of (-2) implies 'unknown'.
|
||
|
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
This object simply reflects the value of the
|
||
|
JOB-INPUT-AUTO-CONTINUE-TIMEOUT object. See the description of that object
|
||
|
for additional information."
|
||
|
::= { prtInputEntry 24 }
|
||
|
|
||
|
|
||
|
prtinputnextindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of prtInputIndex corresponding to the input
|
||
|
subunit which will be used when this input subunit is emptied and
|
||
|
the timeout specified by prtInputMediaLoadTimeout expires. A
|
||
|
value of zero(0) indicates that auto input switching will not
|
||
|
occur when this input subunit is emptied. If the timeout
|
||
|
specified by prtInputLoadMediaTimeout expires and this value is
|
||
|
zero(0), the job will be aborted. A value of (-1) means other.
|
||
|
The value (-2) means 'unknown' and specifically indicates that an
|
||
|
implementation specific method will determine the next input
|
||
|
subunit to use at the time this subunit is emptied and the
|
||
|
timeout expires. The value(-3) means input switching is not
|
||
|
supported for this subunit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
This object reflects the state of JOB-INPUT-AUTO-CONTINUE-MODE
|
||
|
and JOB-INPUT-AUTO-CONTINUE-TIMEOUT. If
|
||
|
JOB-INPUT-AUTO-CONTINUE-TIMEOUT is set to -1 or
|
||
|
JOB-INPUT-AUTO-CONTINUE-MODE is set up to cancel the job,
|
||
|
this object will return 0. If JOB-INPUT-AUTO-CONTINUE-TIMEOUT
|
||
|
is >= 0 and JOB-INPUT-AUTO-CONTINUE-MODE is not set up to
|
||
|
cancel the job, this object will return -2, meaning that
|
||
|
a product-specific tray switching action will occur."
|
||
|
::= { prtInputEntry 26 }
|
||
|
|
||
|
|
||
|
prtoutputtype OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePunknown(2),
|
||
|
ePremovableBin(3),
|
||
|
ePunRemovableBin(4),
|
||
|
ePcontinuousRollDevice(5),
|
||
|
ePmailBox(6),
|
||
|
ePcontinousFanFold(7)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The type of technology supported by this output sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4000 Series has two built-in output bins: a face-down
|
||
|
bin located at the top of the printer and a face-up bin located
|
||
|
at the rear of the printer. However, neither of these bins is
|
||
|
firmware-selectable, so both bins are considered together as the
|
||
|
'standard' bin. LaserJet 4000 Series supports HCO devices as well as a
|
||
|
stacker/stapler, but these devices are currently T.B.D."
|
||
|
::= { prtOutputEntry 2 }
|
||
|
|
||
|
|
||
|
prtoutputcapacityunit OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePtenThousandthsOfInches(3),
|
||
|
ePmicrometers(4),
|
||
|
ePsheets(8),
|
||
|
ePfeet(16),
|
||
|
ePmeters(17)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The unit of measurement for use in calculating and relaying
|
||
|
capacity values for this output sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
A sheet is a single piece of 20 pound paper."
|
||
|
::= { prtOutputEntry 3 }
|
||
|
|
||
|
|
||
|
prtoutputmaxcapacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum capacity of this output sub-unit in output
|
||
|
sub-unit capacity units (PrtCapacityUnitTC). There is no
|
||
|
convention associated with the media itself so this value
|
||
|
essentially reflects claimed capacity. If this output
|
||
|
sub-unit can reliably sense this value, the value is
|
||
|
sensed by the printer and may not be changed by management
|
||
|
requests; otherwise, the value may be written
|
||
|
(by a Remote Control Panel or a Management Application).
|
||
|
The value (-1) means other and specifically indicates
|
||
|
that the sub-unit places no restrictions on this parameter.
|
||
|
The value (-2) means unknown.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML OUTBINn-MAXIMUM-CAPACITY.
|
||
|
LaserJet 4000 Series cannot sense the amount of paper in its standard output
|
||
|
bin; however, the face-up bin can hold 50 sheets of 20lb. paper,
|
||
|
and the face-down bin can hold 250 sheets. External output devices
|
||
|
are currently T.B.D."
|
||
|
::= { prtOutputEntry 4 }
|
||
|
|
||
|
|
||
|
prtoutputremainingcapacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The remaining capacity of the possible output sub-unit
|
||
|
capacity in output sub-unit capacity units (PrtCapacityUnitTC)
|
||
|
of this output sub-unit. If this output sub-unit can
|
||
|
reliably sense this value, the value is sensed by the
|
||
|
printer and may not be modified by management requests;
|
||
|
otherwise, the value may be written (by
|
||
|
a Remote Control Panel or a Management
|
||
|
Application). The value (-1) means other and
|
||
|
specifically indicates that the sub-unit places no
|
||
|
restrictions on this parameter. The value (-2) means
|
||
|
unknown. The value (-3) means that the printer knows that
|
||
|
there remains capacity for at least one unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML NOT-READY-OUTBIN-FULL and
|
||
|
STATUS-OUTBIN-FULL.
|
||
|
LaserJet 4000 Series is capable of determining when the face-down
|
||
|
bin goes full, but not the level of that bin. LaserJet 4000 Series
|
||
|
is not capable of determining whether the face-up bin
|
||
|
is full. RemainingCapacity capabilities of the
|
||
|
stapler/stacker, as well as unplanned HCO devices,
|
||
|
are currently T.B.D.
|
||
|
LaserJet 4000 Series will report a value of 0 when the face-down
|
||
|
bin is full and -3 when the face down bin is not full."
|
||
|
::= { prtOutputEntry 5 }
|
||
|
|
||
|
|
||
|
prtoutputstatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The current status of this output sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML NOT-READY-OUTBIN-MISSING and
|
||
|
STATUS-OUTBIN-MISING.
|
||
|
The default values assume all bins are empty.
|
||
|
See SubUnitStatus in RFC1759 Printer MIB for details on values reported by
|
||
|
this object. LaserJet 4000 Series will not include values Available and Standby (2),
|
||
|
Available and Active (4), Unknown (5) or Transitioning to Intended State
|
||
|
(64).
|
||
|
Values returned by the firmware are detailed in the
|
||
|
following table. 'Value Or'd Due To Condition' indicates
|
||
|
that the specified value will be logically or'd into the
|
||
|
value for this object when the specified Condition occurs.
|
||
|
Condition Value Or'd Due To Condition
|
||
|
----------------------- ------------------------
|
||
|
Binder Error 3
|
||
|
Bin full, binder empty,
|
||
|
bind limit reached, binder
|
||
|
align error, bin attention
|
||
|
error, or bin attention
|
||
|
warning 1
|
||
|
Bin is current bin and
|
||
|
paper is moving 6
|
||
|
Bin is the bin responsible
|
||
|
for Bin Full error message
|
||
|
being displayed 16 + 32
|
||
|
Value 1 or 3 is Or'd in 8 "
|
||
|
::= { prtOutputEntry 6 }
|
||
|
|
||
|
|
||
|
prtoutputname OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..15))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The name assigned to this output sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML OUTBINn-NAME.
|
||
|
The characters must be in the range 20H to 7FH except
|
||
|
5C cannot be used. When this string is displayed on
|
||
|
the control panel the Roman-8 symbol set is used."
|
||
|
::= { prtOutputEntry 7 }
|
||
|
|
||
|
|
||
|
prtoutputvendorname OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The vendor name of this output sub-unit.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtOutputEntry 8 }
|
||
|
|
||
|
|
||
|
prtoutputmodel OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The name assigned to this output sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4000 Series does not support a model number for its
|
||
|
built-in output bins. This object may change in the
|
||
|
future when external output devices are added."
|
||
|
::= { prtOutputEntry 9 }
|
||
|
|
||
|
|
||
|
prtoutputversion OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The version of this output sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Returns device-specific information about the configuration
|
||
|
of the output bin. May include information about the type of
|
||
|
processing that can be done to media sent to this bin;
|
||
|
processing includes but is not limited to binding, punching,
|
||
|
folding and sealing. Format of this object is specified by
|
||
|
the output device documentation."
|
||
|
::= { prtOutputEntry 10 }
|
||
|
|
||
|
|
||
|
prtoutputserialnumber OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The serial number assigned to this output sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4000 Series does not support a serial number for output
|
||
|
devices."
|
||
|
::= { prtOutputEntry 11 }
|
||
|
|
||
|
|
||
|
prtoutputdescription OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
" A free-form text description of this output sub-unit in the
|
||
|
localization specified by prtGeneralCurrentLocalization.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtOutputEntry 12 }
|
||
|
|
||
|
|
||
|
prtoutputsecurity OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePon(3),
|
||
|
ePoff(4),
|
||
|
ePnotPresent(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates if this output sub-unit has some security associated
|
||
|
with it and if that security is enabled or not.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
No security mechanism provided."
|
||
|
::= { prtOutputEntry 13 }
|
||
|
|
||
|
|
||
|
prtoutputdimunit OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePtenThousandthsOfInches(3),
|
||
|
ePmicrometers(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The unit of measurement for use in calculating and relaying
|
||
|
dimensional values for this output sub-unit.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
See the description for prtInputDimUnit for a table
|
||
|
of supported paper sizes and their dimensions for LaserJet 4000 Series."
|
||
|
::= { prtOutputEntry 14 }
|
||
|
|
||
|
|
||
|
prtoutputmaxdimfeeddir OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum dimensions supported by this output sub-unit
|
||
|
for measurements taken parallel relative to the feed
|
||
|
direction associated with that sub-unit in output
|
||
|
sub-unit dimensional units (MediaUnit). If this output
|
||
|
sub-unit can reliably sense this value, the value is
|
||
|
sensed by the printer and may not be changed with
|
||
|
management protocol operations.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4000 Series has two output bins in the base product:
|
||
|
a face-up bin on the back of the engine and a face-down bin on
|
||
|
the top of the engine. These bins are not firmware-selectable;
|
||
|
instead, paper is diverted to the face-down bin only if the face-up
|
||
|
bin is physically closed. Therefore, these bins are considered
|
||
|
together as the 'standard' bin.
|
||
|
The value returned by this object depends on the value
|
||
|
of prtOutputDimUnit. It is 140000 if prtOutputDimUnit is
|
||
|
ePtenThousandthsOfInches or 355600 if prtOutputDimUnit is ePmicrometers."
|
||
|
::= { prtOutputEntry 15 }
|
||
|
|
||
|
|
||
|
prtoutputmaxdimxfeeddir OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum dimensions supported by this output sub-unit
|
||
|
for measurements taken ninety degrees relative to the
|
||
|
feed direction associated with that sub-unit in output
|
||
|
sub-unit dimensional units (MediaUnit). If this output
|
||
|
sub-unit can reliably sense this value, the value is
|
||
|
sensed by the printer and may not be changed with
|
||
|
management protocol operations.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4000 Series has two output bins in the base product:
|
||
|
a face-up bin on the back of the engine and a face-down bin on
|
||
|
the top of the engine. These bins are not firmware-selectable;
|
||
|
instead, paper is diverted to the face-down bin only if the face-up
|
||
|
bin is physically closed. Therefore, these bins are considered
|
||
|
together as the 'standard' bin.
|
||
|
The value returned by this object depends on the value
|
||
|
of prtOutputDimUnit. It is 85000 if prtOutputDimUnit is
|
||
|
ePtenThousandthsOfInches and 215900 if prtOutputDimUnit
|
||
|
is ePmicrometers."
|
||
|
::= { prtOutputEntry 16 }
|
||
|
|
||
|
|
||
|
prtoutputmindimfeeddir OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The minimum dimensions supported by this output sub-unit
|
||
|
for measurements taken parallel relative to the feed
|
||
|
direction associated with that sub-unit in output
|
||
|
sub-unit dimensional units (DimUnit). If this output
|
||
|
sub-unit can reliably sense this value, the value is
|
||
|
sensed by the printer and may not be changed with
|
||
|
management protocol operations.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4000 Series has two output bins in the base product:
|
||
|
a face-up bin on the back of the engine and a face-down bin on
|
||
|
the top of the engine. These bins are not firmware-selectable;
|
||
|
instead, paper is diverted to the face-down bin only if the face-up
|
||
|
bin is physically closed. Therefore, these bins are considered
|
||
|
together as the 'standard' bin.
|
||
|
The value returned by this object depends on the value
|
||
|
of prtOutputDimUnit. It is 50000 if prtOutputDimUnit is
|
||
|
ePtenThousandthsOfInches or 127000 if prtOutputDimUnit is
|
||
|
ePmicrometers."
|
||
|
::= { prtOutputEntry 17 }
|
||
|
|
||
|
|
||
|
prtoutputmindimxfeeddir OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The minimum dimensions supported by this output sub-unit
|
||
|
for measurements taken ninety degrees relative to the
|
||
|
feed direction associated with that sub-unit in output
|
||
|
sub-unit dimensional units (DimUnit). If this output
|
||
|
sub-unit can reliably sense this value, the value is
|
||
|
sensed by the printer and may not be changed with
|
||
|
management protocol operations.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4000 Series has two output bins in the base product:
|
||
|
a face-up bin on the back of the engine and a face-down bin on
|
||
|
the top of the engine. These bins are not firmware-selectable;
|
||
|
instead, paper is diverted to the face-down bin only if the face-up
|
||
|
bin is physically closed. Therefore, these bins are considered
|
||
|
together as the 'standard' bin.
|
||
|
The value returned by this object depends on the value
|
||
|
of prtOutputDimUnit. It is 30000 if prtOutputDimUnit is
|
||
|
ePtenThousandthsOfInches or 76200 if prtOutputDimUnit is ePmicrometers."
|
||
|
::= { prtOutputEntry 18 }
|
||
|
|
||
|
|
||
|
prtoutputstackingorder OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePunknown(2),
|
||
|
ePfirstToLast(3),
|
||
|
ePlastToFirst(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The current state of the stacking order for the
|
||
|
associated output sub-unit. `FirstToLast' means
|
||
|
that as pages are output the front of the next page is
|
||
|
placed against the back of the previous page.
|
||
|
`LasttoFirst' means that as pages are output the back
|
||
|
of the next page is placed against the front of the
|
||
|
previous page.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML OUTBINn-STACK-ORDER."
|
||
|
::= { prtOutputEntry 19 }
|
||
|
|
||
|
|
||
|
prtoutputpagedeliveryorientation OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePfaceUp(3),
|
||
|
ePfaceDown(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The reading surface that will be `up' when pages are
|
||
|
delivered to the associated output sub-unit. Values are
|
||
|
faceUp and faceDown. (Note: interpretation of these
|
||
|
values is in general context-dependent based on locale;
|
||
|
presentation of these values to an end-user should be
|
||
|
normalized to the expectations of the user).
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtOutputEntry 20 }
|
||
|
|
||
|
|
||
|
prtoutputbursting OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePon(3),
|
||
|
ePoff(4),
|
||
|
ePnotPresent(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object indicates that the outputting sub-unit
|
||
|
supports bursting, and if so, whether the feature is enabled.
|
||
|
Bursting is the process by which continuous media is separated
|
||
|
into individual sheets, typically by bursting along pre-formed
|
||
|
perforations.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtOutputEntry 21 }
|
||
|
|
||
|
|
||
|
prtoutputdecollating OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePon(3),
|
||
|
ePoff(4),
|
||
|
ePnotPresent(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object indicates that the output supports
|
||
|
supports decollating, and if so, whether the feature
|
||
|
is enabled. Decollating is the process by which the
|
||
|
individual parts within a multi-part form are separated
|
||
|
and sorted into separate stacks for each part.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtOutputEntry 22 }
|
||
|
|
||
|
|
||
|
prtoutputpagecollated OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePon(3),
|
||
|
ePoff(4),
|
||
|
ePnotPresent(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object indicates that the output sub-unit
|
||
|
supports page collation, and if so, whether the feature is
|
||
|
enabled. See glossary for definition of how this document defines
|
||
|
collation.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtOutputEntry 23 }
|
||
|
|
||
|
|
||
|
prtoutputoffsetstacking OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePon(3),
|
||
|
ePoff(4),
|
||
|
ePnotPresent(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This object indicates that the output supports
|
||
|
supports offset stacking, and if so, whether the feature is
|
||
|
enabled. See glossary for how Offset Stacking is defined by this
|
||
|
document.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtOutputEntry 24 }
|
||
|
|
||
|
|
||
|
prtmarkersuppliesdescription OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The description of this supply container/receptacle in the
|
||
|
localization specified by prtGeneralCurrentLocalization.
|
||
|
Refer to Standard Printer MIB for more details."
|
||
|
::= { prtMarkerSuppliesEntry 6 }
|
||
|
|
||
|
|
||
|
prtmarkersuppliesmaxcapacity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum capacity of this supply container/receptacle
|
||
|
expressed in prtMarkerSuppliesSupplyUnit. If this supply
|
||
|
container/receptacle can reliably sense this value, the
|
||
|
value is reported by the printer and is read-only;
|
||
|
otherwise, the value may be written (by a Remote Control
|
||
|
Panel or a Management Application). The value (-1) means
|
||
|
other and specifically indicates that the sub-unit places
|
||
|
no restrictions on this parameter. The value (-2) means
|
||
|
unknown.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4050 Series - LaserJet 4050 Series now has the same toner-mesuring feature
|
||
|
as LaserJet 8100 Series which utilizes the GRIN ASICS's ability to detect the
|
||
|
number of pixels placed on a page. The default value units are
|
||
|
in 10ths of a gram. A 27X toner cartridge holds 460 grams of
|
||
|
toner. Note :a 27A cartidge holds 303 g but we are using the
|
||
|
27X value."
|
||
|
::= { prtMarkerSuppliesEntry 8 }
|
||
|
|
||
|
|
||
|
prtmarkersupplieslevel OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The current level if this supply is a container; the
|
||
|
remaining space if this supply is a receptacle. If this
|
||
|
supply container/receptacle can reliably sense this
|
||
|
value, the value is reported by the printer and is
|
||
|
read-only; otherwise, the value may be written (by a
|
||
|
Remote Control Panel or a Management Application). The
|
||
|
value (-1) means other and specifically indicates that
|
||
|
the sub-unit places no restrictions on this parameter.
|
||
|
The value (-2) means unknown. A value of (-3) means that the
|
||
|
printer knows that there is some supply/remaining space,
|
||
|
respectively.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
LaserJet 4050 Series will have a new toner-measuring feature that
|
||
|
utilizes the GRIN ASIC's ability to detect the amount of pixels
|
||
|
that have been placed on a single page. This Pixel-Counting
|
||
|
Gas Gauge should be able to calculate toner levels within 10%.
|
||
|
Because textual printing and graphics printing utilize different
|
||
|
pixel usage, accuracy for the counting algorithms have been
|
||
|
biased toward textual printing. Heavy graphics printing will
|
||
|
cause the cartridge to appear to be emptier than it really is.
|
||
|
Over time however, statistical averaging values that are kept in
|
||
|
NVRAM will help make the gauge more accurate according to
|
||
|
individual customer usage models. The new values will vary
|
||
|
between 0 and 4600 depending on how much toner has been
|
||
|
calculated to have been used."
|
||
|
::= { prtMarkerSuppliesEntry 9 }
|
||
|
|
||
|
|
||
|
prtmediapathmaxspeed OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum printing speed of this media path expressed in
|
||
|
prtMediaPathMaxSpeedUnit's. A value of (-1) implies
|
||
|
'other'.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML PRINT-ENGINE-PERFORMANCE.
|
||
|
The page size for this performance is 8.5x11. The
|
||
|
duplex speed is based on 6 ppm."
|
||
|
::= { prtMediaPathEntry 4 }
|
||
|
|
||
|
|
||
|
prtmediapathmaxmediafeeddir OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum physical media size in the feed direction of this
|
||
|
media path expressed in units of measure specified by
|
||
|
PrtMediaPathMediaSizeUnit. A value of (-1) implies 'unlimited',
|
||
|
a value of (-2) implies 'unknown'.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The value returned by this object depends on the value
|
||
|
of prtMediaPathMediaSizeUnit. It is 140000 if prtMediaPathMediaSizeUnit is
|
||
|
ePtenThousandthsOfInches or 355600 if prtMediaPathMediaSizeUnit is ePmicrometers."
|
||
|
::= { prtMediaPathEntry 5 }
|
||
|
|
||
|
|
||
|
prtmediapathmaxmediaxfeeddir OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The maximum physical media size across the feed direction of
|
||
|
this media path expressed in units of measure specified by
|
||
|
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The value returned by this object depends on the value
|
||
|
of prtMediaPathMediaSizeUnit. It is 85000 if prtMediaPathMediaSizeUnit is
|
||
|
ePtenThousandthsOfInches and 215900 if prtMediaPathMediaSizeUnit is ePmicrometers."
|
||
|
::= { prtMediaPathEntry 6 }
|
||
|
|
||
|
|
||
|
prtmediapathminmediafeeddir OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The minimum physical media size in the feed direction of this
|
||
|
media path expressed in units of measure specified by
|
||
|
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The value returned by this object depends on the value
|
||
|
of prtMediaPathMediaSizeUnit. It is 50000 if prtMediaPathMediaSizeUnit is
|
||
|
ePtenThousandthsOfInches or 127000 if prtMediaPathMediaSizeUnit is ePmicrometers."
|
||
|
::= { prtMediaPathEntry 7 }
|
||
|
|
||
|
|
||
|
prtmediapathminmediaxfeeddir OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The minimum physical media size across the feed direction of
|
||
|
this media path expressed in units of measure specified by
|
||
|
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
The value returned by this object depends on the value
|
||
|
of prtMediaPathMediaSizeUnit. It is 30000 if prtMediaPathMediaSizeUnit is
|
||
|
ePtenThousandthsOfInches or 76200 if prtMediaPathMediaSizeUnit is ePmicrometers."
|
||
|
::= { prtMediaPathEntry 8 }
|
||
|
|
||
|
|
||
|
file-system-max-open-files OBJECT-TYPE
|
||
|
SYNTAX INTEGER(32..512)
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of open files allowed at one time. Opening a
|
||
|
file when the maximum number of files are currently open
|
||
|
will fail.
|
||
|
Additional information:
|
||
|
Indicates the number of open files a
|
||
|
personality (e.g. PCL or PostScript) is guaranteed to be
|
||
|
able to open before the file system runs out of file handles.
|
||
|
After writing this object, the printer
|
||
|
must be rebooted (powercycled) before the change takes effect.
|
||
|
This object supports any value between 32 - 512 inclusive.
|
||
|
If a value Less then 32 then it snaps to 32 if greater then
|
||
|
512 it snaps to 512.
|
||
|
The factory default value is dependent on the amount of
|
||
|
installed RAM. The default value of 32 is when
|
||
|
Memory <= 4MB, 128 is if the memory is > 4MB.
|
||
|
Performing a cold reset sets this object
|
||
|
back to the factory default value. Returns
|
||
|
<noSuchName>
|
||
|
status if attempting to access this object and there
|
||
|
is no storage device is installed.
|
||
|
Default for LaserJet 4000 Series/LaserJet 5000 Series is 32
|
||
|
Default for LaserJet 8000 Series/LaserJet 8100 Series/LaserJet 4050 Series is 128"
|
||
|
::= { settings-file-system 2 }
|
||
|
|
||
|
channelnumberofchannels OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"An indication of how many print data channels the I/O
|
||
|
card supports.
|
||
|
Additional information:
|
||
|
This object is used by the IIO card to tell the
|
||
|
peripheral firmware how many logical channels will be used by
|
||
|
the card. This object can only be set once per physical
|
||
|
channel. If an attempt is made to set it a subsequent time
|
||
|
it is ignored and an return code of
|
||
|
<genErr>. is returned.
|
||
|
If new firmware is dynamically downloaded to the I/O
|
||
|
card, and if that firmware uses more logical channels, it is
|
||
|
necessary to reset the printer."
|
||
|
::= { channel 1 }
|
||
|
|
||
|
|
||
|
channelprinteralert OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Identifies the values of prtAlertIndex,
|
||
|
prtAlertSeverityLevel, prtAlertGroup,
|
||
|
prtAlertGroupIndex, prtAlertLocation, and prtAlertCode
|
||
|
for the latest critical evnet in the prtAlertTable. The
|
||
|
binary string is defined as following:
|
||
|
------------------------------------------------------
|
||
|
Field | Filed | Description
|
||
|
Offset | Length |
|
||
|
------------------------------------------------------
|
||
|
0 | 4 | the value of prtAlertIndex
|
||
|
4 | 4 | the value of prtAlertSeverityLevel
|
||
|
8 | 4 | the value of prtAlertGroup
|
||
|
12 | 4 | the value of prtAlertGroupIndex
|
||
|
16 | 4 | the value of prtAlertLocation
|
||
|
20 | 4 | the value of prtAlertCode
|
||
|
------------------------------------------------------
|
||
|
Each field is in Big Endian style.
|
||
|
Additional information:
|
||
|
This object is used to pass alert information
|
||
|
from the peripheral to the IIO card. The standard printer
|
||
|
MIB contains the following description:
|
||
|
|
||
|
printerAlert TRAP-TYPE
|
||
|
ENTERPRISE printerV1Alert
|
||
|
VARIABLES { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup,
|
||
|
prtAlertGroupIndex, prtAlertLocation, prtAlertCode }
|
||
|
DESCRIPTION
|
||
|
'This trap is sent whenever a critical event is added to the
|
||
|
prtAlertTable.'
|
||
|
|
||
|
In order to provide this information in the trap packet, the
|
||
|
IIO card enables traps on channelPrinterAlert. When a
|
||
|
critical alert is generated the peripheral fills the
|
||
|
appropriate value into this object and sends it to the card.
|
||
|
This object is a structure which contains 24 bytes of data.
|
||
|
The structure is:
|
||
|
|
||
|
struct structAlertInfo {
|
||
|
sint32 prtAlertIndex;
|
||
|
sint32 prtAlertSeverityLevel;
|
||
|
sint32 prtAlertGroup;
|
||
|
sint32 prtAlertGroupIndex;
|
||
|
sint32 prtAlertLocation;
|
||
|
sint32 prtAlertCode;
|
||
|
} thisAlertData;"
|
||
|
::= { channel 2 }
|
||
|
|
||
|
|
||
|
channeltype OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eChOther(1),
|
||
|
eChAppleTalkPAP(7),
|
||
|
eChLPDServer(8),
|
||
|
eChNetwareRPrinter(9),
|
||
|
eChNetwarePServer(10),
|
||
|
eChPort9100(11),
|
||
|
eChDLCLLCPort(15),
|
||
|
eChBidirPortTCP(38)
|
||
|
}
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Identifies the type of MIO print data channel.
|
||
|
Additional information:
|
||
|
After telling the peripheral how many logical
|
||
|
channels will be used, the IIO card tells the printer the
|
||
|
type of each of the channels. The type information is passed
|
||
|
using the channelType object. Values are then saved by the
|
||
|
peripheral and reported when users request the value of
|
||
|
prtChannelType."
|
||
|
::= { channelEntry 2 }
|
||
|
|
||
|
|
||
|
channelprotocolversion OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The version of the protocol used on this MIO print data
|
||
|
channel.
|
||
|
Additional information:
|
||
|
After telling the peripheral how many logical
|
||
|
channels will be used, the IIO card tells the printer the
|
||
|
protocol version of each of the channels. The protocol
|
||
|
version information is passed using the
|
||
|
channelProtocolVersion object. Values are then saved by the
|
||
|
peripheral and reported when users request the value of
|
||
|
prtChannelProtocolVersion."
|
||
|
::= { channelEntry 3 }
|
||
|
|
||
|
|
||
|
channelstate OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eChOther(1),
|
||
|
eChPrintDataAccecped(3),
|
||
|
eChNoDataAccepted(4)
|
||
|
}
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The state of this print data channel. The value
|
||
|
determines whether control information and print data is
|
||
|
allowed through this channel or not.
|
||
|
Additional information:
|
||
|
After telling the peripheral how many logical
|
||
|
channels will be used, the IIO card tells the printer the
|
||
|
state of each of the channels. The state can change from
|
||
|
time to time. The state information is passed using the
|
||
|
channelState object. Values are saved by the peripheral and
|
||
|
reported when users request the value of prtChannelState."
|
||
|
::= { channelEntry 4 }
|
||
|
|
||
|
|
||
|
channelifindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of ifIndex which corresponds to this channel.
|
||
|
Additional information:
|
||
|
After telling the peripheral how many logical
|
||
|
channels will be used, the IIO card tells the printer the
|
||
|
value of the IfIndex for each channel. The IfIndex is used
|
||
|
as part of MIB-II. The values are saved by the peripheral
|
||
|
and reported when users request the value of
|
||
|
prtChannelIfIndex."
|
||
|
::= { channelEntry 5 }
|
||
|
|
||
|
|
||
|
channelstatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Sub-unit status is reported in the entries of the
|
||
|
principle table in the Group that represents the sub-
|
||
|
unit. For sub-units that report a status, there is a
|
||
|
status column in the table and the value of this column
|
||
|
is always an integer formed in the following way.
|
||
|
The SubUnitStatus is an integer that is the sum of 5
|
||
|
distinct values, Availability, Non-Critical, Critical,
|
||
|
On-line, and Transitioning. These values are:
|
||
|
Availability value
|
||
|
Available and Idle 0 000'b
|
||
|
Available and Standby 2 010'b
|
||
|
Available and Active 4 100'b
|
||
|
Available and Busy 6 110'b
|
||
|
Unavailable and OnRequest 1 001'b
|
||
|
Unavailable because Broken 3 011'b
|
||
|
Unknown 5 101'b
|
||
|
Non-Critical
|
||
|
No Non-Critical Alerts 0
|
||
|
Non-Critical Alerts 8
|
||
|
Critical
|
||
|
No Critical Alerts 0
|
||
|
Critical Alerts 16
|
||
|
On-Line
|
||
|
Intended state is On-Line 0
|
||
|
Intended state is Off-Line 32
|
||
|
Transitioning
|
||
|
At intended state 0
|
||
|
Transitioning to intended state 64
|
||
|
Additional information:
|
||
|
After telling the peripheral how many logical
|
||
|
channels will be used, the IIO card tells the printer the
|
||
|
status of each of the channels. The status can change from
|
||
|
time to time. The status information is passed using the
|
||
|
channelStatus object. Values are saved by the peripheral and
|
||
|
reported when users request the value of prtChannelStatus."
|
||
|
::= { channelEntry 6 }
|
||
|
|
||
|
|
||
|
channelinformation OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS write-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Auxiliary information to allow a printing application to
|
||
|
use the channel for data submission to the printer. An
|
||
|
application capable of using a specific PrtChannelType
|
||
|
should be able to use the combined information from the
|
||
|
prtChannelInformation and other channel and interface
|
||
|
group objects to 'bootstrap' its use of the channel.
|
||
|
prtChannelInformation is not intended to provide a
|
||
|
general channel description, nor to provide information
|
||
|
that is available once the channel is in use. The
|
||
|
encoding and interpretation of the prtChannelInformation
|
||
|
object is specific to channel type. The description of
|
||
|
each PrtChannelType enum value for which
|
||
|
prtChannelInformation is defined specifies the
|
||
|
appropriate encoding and interpretation, including
|
||
|
interaction with other objects. For channel types that
|
||
|
do not specify a prtChannelInformation value, its value
|
||
|
shall be null (0 length). When a new PrtChannelType
|
||
|
enumeration value is registered, its accompanying
|
||
|
description must specify the encoding and interpretation
|
||
|
of the prtChannelInformation value for the channel type.
|
||
|
prtChannelInformation semantics for an existing
|
||
|
PrtChannelType may be added or amended in the same
|
||
|
manner as described in section 2.4.1 for type 2
|
||
|
enumeration values. The prtChannelInformation specifies
|
||
|
values for a collection of channel attributes,
|
||
|
represented as text according to the following rules:
|
||
|
1. The prtChannelInformation is coded in the NVT ASCII
|
||
|
character set. It is not affected by localization.
|
||
|
2. The prtChannelInformation is a list of entries
|
||
|
representing the attribute values. Each entry consists
|
||
|
of the following items, in order:
|
||
|
a. a keyword, composed of alphabetic characters (A-
|
||
|
Z, a-z), that identifies a channel attribute,
|
||
|
b. an Equals Sign (=) to delimit the keyword,
|
||
|
c. a data value, consisting of NVT ASCII graphics
|
||
|
characters (codes 32-126),
|
||
|
d. a Line Feed character (code 10) to delimit the
|
||
|
data value.
|
||
|
No other characters shall be present. Keywords are
|
||
|
case-sensitive. Conventionally, keywords are
|
||
|
capitalized (including each word of a multi-word
|
||
|
keyword), and, since they occupy space in the
|
||
|
prtChannelInformation, they are kept short.
|
||
|
3. If a channel attribute has multiple values, it is
|
||
|
represented by multiple entries with the same keyword,
|
||
|
each specifying one value. Otherwise, there shall be at
|
||
|
most one entry for each attribute.
|
||
|
4. By default, entries may appear in any order. If
|
||
|
there are ordering constraints for particular entries,
|
||
|
these must be specified in their definitions.
|
||
|
5. The prtChannelInformation value may represent
|
||
|
information that is not normally coded in textual form,
|
||
|
or that is coded in a character set other than NVT
|
||
|
ASCII. In these cases, whatever symbolic representation
|
||
|
is conventionally used for the information should be
|
||
|
used for encoding the prtChannelInformation. (For
|
||
|
instance, a binary port value might be represented as a
|
||
|
decimal number, Unicode would be represented in UTF-8
|
||
|
format.)
|
||
|
6. For each PrtChannelType for which
|
||
|
prtChannelInformation entries are defined, the
|
||
|
descriptive text associated with the PrtChannelType
|
||
|
enumeration value shall specify the following
|
||
|
information for each entry:
|
||
|
Title: Brief description phrase, e.g.: 'Port
|
||
|
name,'Service Name,'
|
||
|
Keyword: The keyword value, eg: 'Port,' 'Service'
|
||
|
Syntax: The encoding of the entry value, if it
|
||
|
cannot be directly represented by NVT ASCII,
|
||
|
Status: 'Mandatory,' 'Optional,' or 'Conditionally
|
||
|
Mandatory,'
|
||
|
Multiplicity: 'Single' or 'Multiple,' to indicate
|
||
|
whether the entry may be present multiple times,
|
||
|
Description: Description of the use of the entry,
|
||
|
other information required to complete the definition
|
||
|
(e.g.: ordering contstraints, interactions between
|
||
|
entries).
|
||
|
Applications that interpret prtChannelInformation should
|
||
|
ignore unrecognized entries, so they are not affected if
|
||
|
new entry types are added.
|
||
|
Additional information:
|
||
|
After telling the peripheral how many logical
|
||
|
channels will be used, the IIO card tells the printer the
|
||
|
value of the information value of each of the channels. The
|
||
|
information is auxiliary information used in conjunction with
|
||
|
the channel Type."
|
||
|
::= { channelEntry 7 }
|
||
|
|
||
|
|
||
|
channel-bytes-sent OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The low order 31 bits of the number of bytes sent from
|
||
|
the printer to the host on this logical channel."
|
||
|
::= { channel-entry 2 }
|
||
|
|
||
|
|
||
|
channel-bytes-received OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The low order 31 bits of the number of bytes received by
|
||
|
the printer from the host on this logical channel."
|
||
|
::= { channel-entry 3 }
|
||
|
|
||
|
|
||
|
channel-io-errors OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The low order 31 bits of the number of I/O errors which
|
||
|
have occured on this logical channel."
|
||
|
::= { channel-entry 4 }
|
||
|
|
||
|
|
||
|
channel-jobs-received OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The low order 31 bits of the number of print jobs which
|
||
|
have been received on this logical channel."
|
||
|
::= { channel-entry 5 }
|
||
|
|
||
|
|
||
|
channel-mio OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The number of the MIO card associated with this logical
|
||
|
channel. If this logical channel is not associated with
|
||
|
an MIO card a zero is returned. The value returned for
|
||
|
each logical channel is the MIO card's physical slot
|
||
|
number. The list of supported values should be
|
||
|
documented in the device POS.
|
||
|
Additional information:
|
||
|
The value returned will be zero for channels 1..3.
|
||
|
If an MIOA card is installed, channels 4..10 will
|
||
|
return a value of one or two.
|
||
|
If an MIOB card is installed, channels 11..17 will
|
||
|
return a value of one or two but not the
|
||
|
same as channels 4..10.
|
||
|
When two IIO cards are installed, the value
|
||
|
returned by any channel 4..17 may change after the
|
||
|
printer is power cycled."
|
||
|
::= { channel-entry 6 }
|
||
|
|
||
|
|
||
|
prtchanneltype OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePchSerialPort(3),
|
||
|
ePchIEEE1284Port(5),
|
||
|
ePchAppleTalkPAP(7),
|
||
|
ePchNetwareRPrinter(9),
|
||
|
ePchNetwarePServer(10),
|
||
|
ePchBidirPortTCP(38),
|
||
|
ePchDLCLLCPort(15)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The type of this print data channel. This
|
||
|
object provides the linkage to ChannelType-specific
|
||
|
groups that may (conceptually) extend the prtChannelTable
|
||
|
with additional details about that channel.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
This object, in conjunction with prtChannelProtocolVersion,
|
||
|
replaces the PML object PORTn-DESCRIPTION.
|
||
|
IIO based channels provide their own values."
|
||
|
::= { prtChannelEntry 2 }
|
||
|
|
||
|
|
||
|
prtchannelprotocolversion OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The version of the protocol used on this
|
||
|
channel. The format used for version numbering depends
|
||
|
on prtChannelType.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
This object, in conjunction with prtChannelType,
|
||
|
replaces the PML object PORTn-DESCRIPTION.
|
||
|
IIO-based channels provide their own values.
|
||
|
The channel 1 value includes (separated by semi colons)
|
||
|
different aspectsof the spec: electrical: logical; and
|
||
|
physical connector."
|
||
|
::= { prtChannelEntry 3 }
|
||
|
|
||
|
|
||
|
prtchannelcurrentjobcntllangindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of prtInterpreterIndex corresponding to the
|
||
|
Control Language Interpreter for this channel. This
|
||
|
interpreter defines the syntax used for control
|
||
|
functions, such as querying or changing environment
|
||
|
variables and identifying job boundaries (e.g. PJL,
|
||
|
PostScript, NPAP). Must be 1 or greater.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
This object points to the PJL language. It is
|
||
|
read-only because PJL is the printer's only job
|
||
|
control language."
|
||
|
::= { prtChannelEntry 4 }
|
||
|
|
||
|
|
||
|
prtchanneldefaultpagedesclangindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of prtInterpreterIndex corresponding to the
|
||
|
Page Description Language Interpreter for this channel.
|
||
|
This interpreter defines the default Page Description
|
||
|
Language interpreter to be used for the print data unless
|
||
|
the Control Language is used to select a specific
|
||
|
interpreter (e.g., PCL, PostScript Language,
|
||
|
auto-sense). Must be 1 or greater.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
Replaces PML DEFAULT-PDL. The default points to the
|
||
|
automatic language switcher. If this object is changed
|
||
|
for one channel, all channels will be changed."
|
||
|
::= { prtChannelEntry 5 }
|
||
|
|
||
|
|
||
|
prtchannelstate OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ePother(1),
|
||
|
ePprintDataAccepted(3),
|
||
|
ePnoDataAccepted(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The state of this print data channel. The value determines
|
||
|
whether control information and print data is allowed through
|
||
|
this channel or not.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
IIO-based channels provide their own values for this
|
||
|
object. The base-printer's ports always report a value of
|
||
|
ePprintDataAccepted.
|
||
|
If the printer is offline, that is detected by reading the
|
||
|
Host Resources General Printer Status objects, not by reading
|
||
|
this object."
|
||
|
::= { prtChannelEntry 6 }
|
||
|
|
||
|
|
||
|
prtchannelifindex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The value of ifIndex (in the ifTable; see the interface
|
||
|
section of MIB-2/RFC 1213) which corresponds to this channel.
|
||
|
When more than one row of the ifTable is relevant, this is
|
||
|
the index of the row representing the topmost layer in the
|
||
|
interface hierarchy. A value of zero indicates that no
|
||
|
interface is associated with this channel.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
IIO-based channels provide their own values for this
|
||
|
object."
|
||
|
::= { prtChannelEntry 7 }
|
||
|
|
||
|
|
||
|
prtchannelstatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The current status of the channel.
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
IIO-based channels provide their own values for this
|
||
|
object."
|
||
|
::= { prtChannelEntry 8 }
|
||
|
|
||
|
|
||
|
prtchannelinformation OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Auxiliary information to allow a printing application to use
|
||
|
the channel for data submission to the printer. An application
|
||
|
capable of using a specific PrtChannelType should be able to use
|
||
|
the combined information from the prtChannelInformation and
|
||
|
other channel and interface group objects to 'bootstrap' its use
|
||
|
of the channel. prtChannelInformation is not intended to
|
||
|
provide a general channel description, nor to provide
|
||
|
information that is available once the channel is in use.
|
||
|
The encoding and interpretation of the prtChannelInformation
|
||
|
object is specific to channel type. The description of each
|
||
|
PrtChannelType enum value for which prtChannelInformation is
|
||
|
defined specifies the appropriate encoding and interpretation,
|
||
|
including interaction with other objects. For channel types
|
||
|
that do not specify a prtChannelInformation value, its value
|
||
|
shall be null (0 length).
|
||
|
When a new PrtChannelType enumeration value is registered, its
|
||
|
accompanying description must specify the encoding and
|
||
|
interpretation of the prtChannelInformation value for the
|
||
|
channel type. prtChannelInformation semantics for an existing
|
||
|
PrtChannelType may be added or amended in the same manner as
|
||
|
described in section 2.4.1 for type 2 enumeration values.
|
||
|
The prtChannelInformation specifies values for a collection of
|
||
|
channel attributes, represented as text according to the
|
||
|
following rules:
|
||
|
1. The prtChannelInformation is coded in the NVT ASCII
|
||
|
character set. It is not affected by localization.
|
||
|
2. The prtChannelInformation is a list of entries representing
|
||
|
the attribute values. Each entry consists of the following
|
||
|
items, in order:
|
||
|
a. a keyword, composed of alphabetic characters (A-Z,
|
||
|
a-z), that identifies a channel attribute,
|
||
|
b. an Equals Sign (=) to delimit the keyword,
|
||
|
c. a data value, consisting of NVT ASCII graphics
|
||
|
characters (codes 32-126),
|
||
|
d. a Line Feed character (code 10) to delimit the data
|
||
|
value.
|
||
|
No other characters shall be present.
|
||
|
Keywords are case-sensitive. Conventionally, keywords are
|
||
|
capitalized (including each word of a multi-word keyword),
|
||
|
and, since they occupy space in the prtChannelInformation,
|
||
|
they are kept short.
|
||
|
3. If a channel attribute has multiple values, it is
|
||
|
represented by multiple entries with the same keyword, each
|
||
|
specifying one value. Otherwise, there shall be at most
|
||
|
one entry for each attribute.
|
||
|
4. By default, entries may appear in any order. If there are
|
||
|
ordering constraints for particular entries, these must be
|
||
|
specified in their definitions.
|
||
|
5. The prtChannelInformation value may represent information
|
||
|
that is not normally coded in textual form, or that is coded
|
||
|
in a character set other than NVT ASCII. In these cases,
|
||
|
whatever symbolic representation is conventionally used for
|
||
|
the information should be used for encoding the
|
||
|
prtChannelInformation. (For instance, a binary port value
|
||
|
might be represented as a decimal number, Unicode would
|
||
|
be represented in UTF-8 format.)
|
||
|
6. For each PrtChannelType for which prtChannelInformation
|
||
|
entries are defined, the descriptive text associated with the
|
||
|
PrtChannelType enumeration value shall specify the following
|
||
|
information for each entry:
|
||
|
Title: Brief description phrase, e.g.: 'Port name',
|
||
|
'Service Name',
|
||
|
Keyword: The keyword value, eg: 'Port', 'Service'
|
||
|
Syntax: The encoding of the entry value, if it
|
||
|
cannot be directly represented by NVT ASCII,
|
||
|
Status: 'Mandatory', 'Optional', or 'Conditionally
|
||
|
Mandatory',
|
||
|
Multiplicity: 'Single' or 'Multiple', to indicate whether
|
||
|
the entry may be present multiple times,
|
||
|
Description: Description of the use of the entry, other
|
||
|
information required to complete the
|
||
|
definition (e.g.: ordering contstraints,
|
||
|
interactions between entries).
|
||
|
Applications that interpret prtChannelInformation should ignore
|
||
|
unrecognized entries, so they are not affected if new entry
|
||
|
types are added.
|
||
|
|
||
|
Refer to Standard Printer MIB for more details.
|
||
|
Additional information:
|
||
|
IIO-based channels provide their own values for this
|
||
|
object."
|
||
|
::= { prtChannelEntry 9 }
|
||
|
|
||
|
|
||
|
job-info-outbins-used OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates which output bins this job has delivered
|
||
|
printed pages to. The last OID field for this dynamic
|
||
|
object contains the job ID.
|
||
|
Additional information:
|
||
|
The bins designated by this collection include
|
||
|
the printer's own output bins as well as the `logical output
|
||
|
bins' associated with any attached external paper handling
|
||
|
devices. (The mapping of the physical output bins of an
|
||
|
external paper handling device to its `logical output bins'
|
||
|
depends on the usage mode of the device. For instance, in
|
||
|
`mailbox mode', there is one-to-one correspondence of
|
||
|
`logical output bins' to physical bins, whereas in `stacker
|
||
|
mode', one `logical output bin' may map to several physical
|
||
|
bins.)
|
||
|
|
||
|
Although LaserJet 5000 Series and LaserJet 4000 Series both come with two output
|
||
|
bins -- a face-down bin on the top of the device and a
|
||
|
face-up bin at the back of the device -- firmware will not
|
||
|
provide a means of selecting between the two, nor will it
|
||
|
report which of the two gets used. For this reason, bit 0
|
||
|
(cOutbin1) of this collection is being used to designate
|
||
|
both of these bins together."
|
||
|
::= { job-info 20 }
|
||
|
|
||
|
|
||
|
job-info-physical-outbins-used OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Indicates which physical output bins this job has
|
||
|
delivered printed pages to. The last OID field for this
|
||
|
dynamic object contains the job ID.
|
||
|
Additional information:
|
||
|
The output bins designated by the bits of
|
||
|
this collection include the standard output bin(s) plus the
|
||
|
physical bins of attached external paper handling devices.
|
||
|
The configuration (if any) of external paper handling devices
|
||
|
will determine the mapping of individual bits in this
|
||
|
collection to the physical bins of the devices.
|
||
|
For LaserJet 4050 Series (LaserJet 4050), the cOutbin1 is used for Face Down
|
||
|
bin, cOutbin2 is used for Face Up bin, and 3-15 are used for
|
||
|
the 13 optional output bins (12 plus an extension to the Face
|
||
|
Up bin) for backwards compatibility with LaserJet 8000 Series/LaserJet 8100 Series and
|
||
|
forwards compatibility with future printers. However, since LaserJet 4050 Series
|
||
|
cannot distinguish output going to the Face Up or Face Down
|
||
|
bin in the firmware because the diverter can only be moved
|
||
|
manually, bit 0 (cOutbin1) is being used to designate
|
||
|
both of these bits together. If an external paper handling
|
||
|
output device is connected, then bit 2 (cOutbin3) will
|
||
|
represent the device's first output bin (and so on)."
|
||
|
::= { job-info 22 }
|
||
|
|
||
|
printed-media-simplex-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..930576247)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Total number of simplex pages printed in this media
|
||
|
size.
|
||
|
Additional information:
|
||
|
The 5 usage (simplex/duplex count, simplex/duplex click
|
||
|
charge and paper size total) objects described here and
|
||
|
below detail the usage for the printer for each paper
|
||
|
size defined in the PCL Implementor's Guide and in the
|
||
|
Media Size Table in the hpmib.txt. The OID binding is
|
||
|
based on the click attribute and paper size.
|
||
|
For example:
|
||
|
|
||
|
The format for the OID is as follows:
|
||
|
|
||
|
3.4.1.5.x.y
|
||
|
<-----> | |
|
||
|
| | \
|
||
|
/ | paper size
|
||
|
/ \
|
||
|
PRINTER-CLICK-TOTALS ROOT \
|
||
|
OID click attribute 1..5
|
||
|
|
||
|
x values are 1..5:
|
||
|
|
||
|
1) simplex count
|
||
|
2) simplex click charge
|
||
|
3) duplex count
|
||
|
4) duplex click charge
|
||
|
5) printer or scanner paper size total (i.e. depends if the
|
||
|
root OID is referrring to the printer or scanner).
|
||
|
|
||
|
y : paper size as defined in the Media Size Table in the
|
||
|
hpmib.txt "
|
||
|
::= { printed-media-usage 1 }
|
||
|
|
||
|
|
||
|
printed-media-simplex-charge OBJECT-TYPE
|
||
|
SYNTAX REAL
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Charge for each simplex page printed in this media
|
||
|
size."
|
||
|
::= { printed-media-usage 2 }
|
||
|
|
||
|
|
||
|
printed-media-duplex-count OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..930576247)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Total number of duplex pages printed in this media
|
||
|
size."
|
||
|
::= { printed-media-usage 3 }
|
||
|
|
||
|
|
||
|
printed-media-duplex-charge OBJECT-TYPE
|
||
|
SYNTAX REAL
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Charge for each duplex page printed in this media size.
|
||
|
Additional information:
|
||
|
The click charges for duplex printed media."
|
||
|
::= { printed-media-usage 4 }
|
||
|
|
||
|
|
||
|
printed-media-total-charge OBJECT-TYPE
|
||
|
SYNTAX REAL
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The total charge for pages printed in this media size."
|
||
|
::= { printed-media-usage 5 }
|
||
|
|
||
|
|
||
|