AXIS-VIDEO-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
axis, products
|
||
|
FROM AXIS-ROOT-MIB
|
||
|
MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
|
||
|
FROM SNMPv2-CONF -- RFC 2580
|
||
|
Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
|
||
|
Unsigned32
|
||
|
FROM SNMPv2-SMI -- RFC 2578
|
||
|
SnmpAdminString
|
||
|
FROM SNMP-FRAMEWORK-MIB; -- RFC 3411
|
||
|
|
||
|
video MODULE-IDENTITY
|
||
|
LAST-UPDATED "201609231218Z"
|
||
|
ORGANIZATION
|
||
|
"Axis Communications AB"
|
||
|
CONTACT-INFO
|
||
|
"Postal: Axis Communications AB
|
||
|
Emdalavagen 14
|
||
|
SE-223 69 Lund
|
||
|
Sweden
|
||
|
Phone: +46 (0)46 272 18 00
|
||
|
Fax: +46 (0)46 13 61 30
|
||
|
E-Mail: info@axis.com
|
||
|
Web: www.axis.com"
|
||
|
DESCRIPTION
|
||
|
"Axis Video MIB. Includes HW resources, such as power
|
||
|
supplies, and traps for notifying management stations when
|
||
|
something fails."
|
||
|
REVISION "201609231218Z"
|
||
|
DESCRIPTION
|
||
|
"Updates in the compliance statement. Video products do not support all
|
||
|
objects in general."
|
||
|
REVISION "201212121202Z"
|
||
|
DESCRIPTION
|
||
|
"Initial version."
|
||
|
::= { axis 4 }
|
||
|
|
||
|
-- Object identifiers: all video products return the videoBased OID
|
||
|
--- Note: video cannot be used, since it is used above.
|
||
|
videoBased OBJECT IDENTIFIER
|
||
|
::= { products 1 }
|
||
|
|
||
|
videoObjects OBJECT IDENTIFIER
|
||
|
::= { video 1 }
|
||
|
|
||
|
-- Power supplies
|
||
|
powerSupplyTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PowerSupplyEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Table containing information about all the power supplies
|
||
|
present in the device."
|
||
|
::= { videoObjects 1 }
|
||
|
|
||
|
powerSupplyEntry OBJECT-TYPE
|
||
|
SYNTAX PowerSupplyEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A power supply entry containing information about
|
||
|
a specific power supply."
|
||
|
INDEX { powerSupplyType, powerSupplyId }
|
||
|
::= { powerSupplyTable 1 }
|
||
|
|
||
|
PowerSupplyEntry ::= SEQUENCE {
|
||
|
powerSupplyType INTEGER,
|
||
|
powerSupplyId Unsigned32,
|
||
|
powerSupplyStatus INTEGER
|
||
|
}
|
||
|
|
||
|
powerSupplyType OBJECT-TYPE
|
||
|
SYNTAX INTEGER { common(1), internal(2), external(3) }
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Indicates whether the power supply is mounted externally,
|
||
|
e.g. in a rack, or internally."
|
||
|
::= { powerSupplyEntry 1 }
|
||
|
|
||
|
powerSupplyId OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (1..128)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Used to identify a power supply. The powerSupplyId is unique
|
||
|
within the type, i.e. there can not be two external power
|
||
|
supplies with the same powerSupplyId. There can, however, be one
|
||
|
external and one internal that have the same powerSupplyId."
|
||
|
::= { powerSupplyEntry 2 }
|
||
|
|
||
|
powerSupplyStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { ok(1), failure(2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The status of a power supply."
|
||
|
::= { powerSupplyEntry 3 }
|
||
|
|
||
|
--- Fans
|
||
|
fanTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF FanEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Table containing information about all the fans in the product."
|
||
|
::= { videoObjects 2 }
|
||
|
|
||
|
fanEntry OBJECT-TYPE
|
||
|
SYNTAX FanEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A fan entry contains information about a specific fan."
|
||
|
INDEX { fanType, fanId }
|
||
|
::= { fanTable 1 }
|
||
|
|
||
|
FanEntry ::= SEQUENCE {
|
||
|
fanType INTEGER,
|
||
|
fanId Unsigned32,
|
||
|
fanStatus INTEGER
|
||
|
}
|
||
|
|
||
|
fanType OBJECT-TYPE
|
||
|
SYNTAX INTEGER { common(1), housing(2), rack(3), cpu(4) }
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The type of the fan, i.e. where the fan is mounted."
|
||
|
::= { fanEntry 1 }
|
||
|
|
||
|
fanId OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (1..128)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Used, together with fanType, to identify a fan. The fanId is
|
||
|
unique within the type, i.e. there can not be two fans with the
|
||
|
same fanType and the same fanId."
|
||
|
::= { fanEntry 2 }
|
||
|
|
||
|
fanStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { ok(1), failure(2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The status of a fan."
|
||
|
::= { fanEntry 3 }
|
||
|
|
||
|
--- Temperature Sensors
|
||
|
tempSensorTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF TempSensorEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Table containing information about all the temperature
|
||
|
sensors in the product."
|
||
|
::= { videoObjects 3 }
|
||
|
|
||
|
tempSensorEntry OBJECT-TYPE
|
||
|
SYNTAX TempSensorEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A temperature sensor entry contains information about a
|
||
|
specific temperature sensor."
|
||
|
INDEX { tempSensorType, tempSensorId }
|
||
|
::= { tempSensorTable 1 }
|
||
|
|
||
|
TempSensorEntry ::= SEQUENCE {
|
||
|
tempSensorType INTEGER,
|
||
|
tempSensorId Unsigned32,
|
||
|
tempSensorStatus INTEGER,
|
||
|
tempSensorValue Integer32
|
||
|
}
|
||
|
|
||
|
tempSensorType OBJECT-TYPE
|
||
|
SYNTAX INTEGER { common(1), housing(2), rack(3), cpu(4) }
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The type of the temperature sensor, i.e. where it is mounted."
|
||
|
::= { tempSensorEntry 1 }
|
||
|
|
||
|
tempSensorId OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (1..128)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Used, together with tempSensorType, to identify a temperature
|
||
|
sensor. The tempSensorId is unique within the type, i.e. there
|
||
|
can not be two sensors with the same tempSensorType and the same
|
||
|
tempSensorId."
|
||
|
::= { tempSensorEntry 2 }
|
||
|
|
||
|
tempSensorStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { ok(1), failure(2), outOfBoundary(3) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The status of the temperature sensor."
|
||
|
::= { tempSensorEntry 3 }
|
||
|
|
||
|
tempSensorValue OBJECT-TYPE
|
||
|
SYNTAX Integer32 (-176..150)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The temperature measured by a specific temperature sensor.
|
||
|
The temperature is given in degrees Celsius."
|
||
|
::= { tempSensorEntry 4 }
|
||
|
|
||
|
--- Physical video channels
|
||
|
videoChannelTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF VideoChannelEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A list of video channel information, one entry for each
|
||
|
physical video channel."
|
||
|
::= { videoObjects 4 }
|
||
|
|
||
|
videoChannelEntry OBJECT-TYPE
|
||
|
SYNTAX VideoChannelEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A video channel entry contains information about a specific
|
||
|
physical video channel."
|
||
|
INDEX { videoChannelId }
|
||
|
::= { videoChannelTable 1 }
|
||
|
|
||
|
VideoChannelEntry ::= SEQUENCE {
|
||
|
videoChannelId Unsigned32,
|
||
|
videoSignalStatus INTEGER
|
||
|
}
|
||
|
|
||
|
videoChannelId OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (1..8192)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Used to identify a physical video channel."
|
||
|
::= { videoChannelEntry 1 }
|
||
|
|
||
|
videoSignalStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { signalOk(1), noSignal(2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The status of the video signal for a channel."
|
||
|
::= { videoChannelEntry 2 }
|
||
|
|
||
|
--- Physical audio channels
|
||
|
audioChannelTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF AudioChannelEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A list of audio signal information, one entry for each
|
||
|
physical audio channel."
|
||
|
::= { videoObjects 5 }
|
||
|
|
||
|
audioChannelEntry OBJECT-TYPE
|
||
|
SYNTAX AudioChannelEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An audio signal entry contains information about a specific
|
||
|
physical audio signal."
|
||
|
INDEX { audioChannelId }
|
||
|
::= { audioChannelTable 1 }
|
||
|
|
||
|
AudioChannelEntry ::= SEQUENCE {
|
||
|
audioChannelId Unsigned32,
|
||
|
audioSignalStatus INTEGER
|
||
|
}
|
||
|
|
||
|
audioChannelId OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (1..8192)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Used to identify a physical audio channel."
|
||
|
::= { audioChannelEntry 1 }
|
||
|
|
||
|
audioSignalStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { signalOk(1), noSignal(2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The status of the audio signal for a channel."
|
||
|
::= { audioChannelEntry 2 }
|
||
|
|
||
|
--- Open Casing Detector
|
||
|
casingTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CasingEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A list of casing status, one entry for each casing."
|
||
|
::= { videoObjects 6 }
|
||
|
|
||
|
casingEntry OBJECT-TYPE
|
||
|
SYNTAX CasingEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A casing entry contains information about a specific casing."
|
||
|
INDEX { casingId }
|
||
|
::= { casingTable 1 }
|
||
|
|
||
|
CasingEntry ::= SEQUENCE {
|
||
|
casingId Unsigned32,
|
||
|
casingName SnmpAdminString,
|
||
|
casingStatus INTEGER
|
||
|
}
|
||
|
|
||
|
casingId OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (1..32)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Used to identify a casing."
|
||
|
::= { casingEntry 1 }
|
||
|
|
||
|
casingName OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString (SIZE(0..32))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Used to identify a casing. If the original string is longer than the
|
||
|
specified length then the middle of the string will be replaced by '..'
|
||
|
in such a way that the length of the string becomes 32 characters
|
||
|
anyway."
|
||
|
::= { casingEntry 2 }
|
||
|
|
||
|
casingStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { closed(1), open(2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The status of the casing."
|
||
|
::= { casingEntry 3 }
|
||
|
|
||
|
--- { videoObjects 7 }, reserved for PTZ
|
||
|
|
||
|
--- Storage
|
||
|
storageTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF StorageEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A list of storage media properties, one entry for each storage media."
|
||
|
::= { videoObjects 8 }
|
||
|
|
||
|
storageEntry OBJECT-TYPE
|
||
|
SYNTAX StorageEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A storage media contains information about a specific medium."
|
||
|
INDEX { storageId }
|
||
|
::= { storageTable 1 }
|
||
|
|
||
|
StorageEntry ::= SEQUENCE {
|
||
|
storageId Unsigned32,
|
||
|
storageName SnmpAdminString,
|
||
|
storageDisruptionDetected INTEGER
|
||
|
}
|
||
|
|
||
|
storageId OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (1..128)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Used to identify a storage."
|
||
|
::= { storageEntry 1 }
|
||
|
|
||
|
storageName OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString (SIZE(0..32))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Used to identify a storage medium. If the original string is longer
|
||
|
than the specified length then the middle of the string will be
|
||
|
replaced by '..' in such a way that the length of the string becomes 32
|
||
|
characters anyway."
|
||
|
::= { storageEntry 2 }
|
||
|
|
||
|
storageDisruptionDetected OBJECT-TYPE
|
||
|
SYNTAX INTEGER { no(1), yes(2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The status of the storage medium."
|
||
|
::= { storageEntry 3 }
|
||
|
|
||
|
--- { videoObjects 9 }, reserved for tampering
|
||
|
|
||
|
-- Objects used in Private Enterprise Traps
|
||
|
videoNotifications OBJECT IDENTIFIER
|
||
|
::= { video 2 }
|
||
|
|
||
|
videoNotificationPrefix OBJECT IDENTIFIER
|
||
|
::= { videoNotifications 0 }
|
||
|
|
||
|
alarmID OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indentifies a certain alarm event in a unique way.
|
||
|
This means that there cannot be any alarm event that has the same ID
|
||
|
during a finite period of time."
|
||
|
::= { videoNotifications 1 }
|
||
|
|
||
|
alarmName OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A string that identifies which kind of alarm this is. During a certain
|
||
|
time it is possible that alarms with the same name occur."
|
||
|
::= { videoNotifications 2 }
|
||
|
|
||
|
alarmText OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Detailed description of the alarm."
|
||
|
::= { videoNotifications 3 }
|
||
|
|
||
|
videoConformance OBJECT IDENTIFIER
|
||
|
::= { video 3 }
|
||
|
|
||
|
videoGroups OBJECT IDENTIFIER
|
||
|
::= { videoConformance 1 }
|
||
|
|
||
|
videoCompliances OBJECT IDENTIFIER
|
||
|
::= { videoConformance 2 }
|
||
|
|
||
|
alarmNew NOTIFICATION-TYPE
|
||
|
OBJECTS { alarmID, alarmName, alarmText }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is sent when a new Alarm is
|
||
|
generated that has a corresponding cleared state."
|
||
|
::= { videoNotificationPrefix 1 }
|
||
|
|
||
|
alarmCleared NOTIFICATION-TYPE
|
||
|
OBJECTS { alarmID, alarmName, alarmText }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when an alarm is
|
||
|
cleared that was previous sent as a new Alarm."
|
||
|
::= { videoNotificationPrefix 2 }
|
||
|
|
||
|
alarmSingle NOTIFICATION-TYPE
|
||
|
OBJECTS { alarmID, alarmName, alarmText }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is sent when a new Alarm is
|
||
|
generated that has no corresponding cleared state."
|
||
|
::= { videoNotificationPrefix 3 }
|
||
|
|
||
|
-- Groups
|
||
|
videoObjectGroup OBJECT-GROUP
|
||
|
OBJECTS { powerSupplyStatus, fanStatus, tempSensorStatus,
|
||
|
tempSensorValue, videoSignalStatus, audioSignalStatus,
|
||
|
casingName, casingStatus, storageDisruptionDetected,
|
||
|
storageName, alarmID, alarmName, alarmText }
|
||
|
STATUS obsolete
|
||
|
DESCRIPTION
|
||
|
"A collection of video objects."
|
||
|
::= { videoGroups 1 }
|
||
|
|
||
|
videoNotificationGroup NOTIFICATION-GROUP
|
||
|
NOTIFICATIONS { alarmNew, alarmCleared, alarmSingle }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A collection of video notifications."
|
||
|
::= { videoGroups 2 }
|
||
|
|
||
|
tempSensorGroup OBJECT-GROUP
|
||
|
OBJECTS { tempSensorStatus, tempSensorValue }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Objects related to Axis temperature sensors."
|
||
|
::= { videoGroups 3 }
|
||
|
|
||
|
casingGroup OBJECT-GROUP
|
||
|
OBJECTS { casingName, casingStatus }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Objects related to Axis casing."
|
||
|
::= { videoGroups 4 }
|
||
|
|
||
|
storageGroup OBJECT-GROUP
|
||
|
OBJECTS { storageDisruptionDetected, storageName }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Objects related to Axis storage."
|
||
|
::= { videoGroups 5 }
|
||
|
|
||
|
-- Compliance Statements
|
||
|
videoComplianceRev2 MODULE-COMPLIANCE
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The compliance statement for Axis video entities."
|
||
|
|
||
|
MODULE -- this module
|
||
|
|
||
|
MANDATORY-GROUPS { videoNotificationGroup }
|
||
|
|
||
|
GROUP powerSupplyStatus
|
||
|
DESCRIPTION
|
||
|
"This group is mandatory for all AXIS video products that have
|
||
|
redundant power supply for backup, for which it is possible to
|
||
|
check whether it is still working."
|
||
|
|
||
|
GROUP fanStatus
|
||
|
DESCRIPTION
|
||
|
"This group is mandatory for all AXIS video products that have
|
||
|
fans, for which the state can be obtained."
|
||
|
|
||
|
GROUP tempSensorGroup
|
||
|
DESCRIPTION
|
||
|
"This group is mandatory for all AXIS video products that have
|
||
|
temperature sensors, for which a state can be obtained."
|
||
|
|
||
|
GROUP videoSignalStatus
|
||
|
DESCRIPTION
|
||
|
"This group is mandatory for all AXIS video products that have
|
||
|
video cameras connected for which it is possible to check the
|
||
|
connection state. Typically this is an encoder product."
|
||
|
|
||
|
GROUP audioSignalStatus
|
||
|
DESCRIPTION
|
||
|
"This group is mandatory for all AXIS video products to which a
|
||
|
a microphone can be connected, for which the state can be
|
||
|
detected."
|
||
|
|
||
|
GROUP casingGroup
|
||
|
DESCRIPTION
|
||
|
"This group is mandatory for all AXIS video products that have
|
||
|
a casing box, for which it is possible to check the status."
|
||
|
|
||
|
GROUP storageGroup
|
||
|
DESCRIPTION
|
||
|
"This group is mandatory for all AXIS video products that have a
|
||
|
storage device connected and for which it is possible to check the
|
||
|
state."
|
||
|
|
||
|
::= { videoCompliances 2 }
|
||
|
|
||
|
videoCompliance MODULE-COMPLIANCE
|
||
|
STATUS obsolete
|
||
|
DESCRIPTION
|
||
|
"The compliance statement in a previous version of this MIB for Axis
|
||
|
video entities."
|
||
|
|
||
|
MODULE -- this module
|
||
|
|
||
|
MANDATORY-GROUPS { videoObjectGroup }
|
||
|
|
||
|
GROUP videoNotificationGroup
|
||
|
DESCRIPTION
|
||
|
"This group doesn't need to be supported."
|
||
|
|
||
|
::= { videoCompliances 1 }
|
||
|
|
||
|
END -- end of module AXIS-VIDEO-MIB.
|