-- CISCO-STACKWISE-MIB.my: Cisco StackWise MIB
|
||
|
--
|
||
|
-- Description of managed objects for the StackWise technology.
|
||
|
--
|
||
|
-- October 2005, Gunnar Lovblom
|
||
|
--
|
||
|
-- Copyright (c) 2005, 2008-2011 by Cisco Systems Inc.
|
||
|
-- All rights reserved.
|
||
|
-- ******************************************************************
|
||
|
|
||
|
CISCO-STACKWISE-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
Unsigned32,
|
||
|
MODULE-IDENTITY,
|
||
|
NOTIFICATION-TYPE,
|
||
|
OBJECT-TYPE
|
||
|
FROM SNMPv2-SMI
|
||
|
NOTIFICATION-GROUP,
|
||
|
MODULE-COMPLIANCE,
|
||
|
OBJECT-GROUP
|
||
|
FROM SNMPv2-CONF
|
||
|
entPhysicalIndex
|
||
|
FROM ENTITY-MIB
|
||
|
ifIndex
|
||
|
FROM IF-MIB
|
||
|
TruthValue,
|
||
|
MacAddress,
|
||
|
TEXTUAL-CONVENTION
|
||
|
FROM SNMPv2-TC
|
||
|
SnmpAdminString
|
||
|
FROM SNMP-FRAMEWORK-MIB
|
||
|
EntPhysicalIndexOrZero
|
||
|
FROM CISCO-TC
|
||
|
ciscoMgmt
|
||
|
FROM CISCO-SMI;
|
||
|
|
||
|
|
||
|
ciscoStackWiseMIB MODULE-IDENTITY
|
||
|
LAST-UPDATED "201112120000Z"
|
||
|
ORGANIZATION "Cisco Systems, Inc."
|
||
|
CONTACT-INFO
|
||
|
"Cisco Systems
|
||
|
Customer Service
|
||
|
|
||
|
Postal: 170 W Tasman Drive
|
||
|
San Jose, CA 95134
|
||
|
|
||
|
Tel: +1 800 553-NETS
|
||
|
|
||
|
E-mail: cs-dsbu@cisco.com"
|
||
|
DESCRIPTION
|
||
|
"This MIB module contain a collection of managed objects
|
||
|
that apply to network devices supporting the Cisco
|
||
|
StackWise(TM) technology.
|
||
|
|
||
|
The StackWise technology provides a method for collectively
|
||
|
utilizing a stack of switches to create a single switching
|
||
|
unit.
|
||
|
|
||
|
The data stack is used for switching data packets and, in
|
||
|
power stack, switches are connected by special stack power
|
||
|
cables to share power. Moreover, stackwise is the concept
|
||
|
for combining multiple systems to give an impression of a
|
||
|
single system so that is why both power stack and data stack
|
||
|
are supported by single MIB.
|
||
|
|
||
|
Terminology:
|
||
|
Stack - A collection of switches connected by the
|
||
|
Cisco StackWise technology.
|
||
|
|
||
|
Master - The switch that is managing the stack.
|
||
|
|
||
|
Member - A switch in the stack that is
|
||
|
NOT the stack master.
|
||
|
|
||
|
Ring - Components that makes up the connections
|
||
|
between the switches in order to create a
|
||
|
stack.
|
||
|
|
||
|
Stackport - A special physical connector used by the ring.
|
||
|
It is possible for a switch have more than
|
||
|
one stackport.
|
||
|
|
||
|
SDM - Switch Database Management.
|
||
|
|
||
|
Stack Power - A collection of switches connected by special
|
||
|
stack power cables to share the power of
|
||
|
inter-connected power supplies across all switches
|
||
|
requiring power. Stack Power is managed by a
|
||
|
single data stack.
|
||
|
|
||
|
Jack-Jack - It is a device that provides the Power Shelf
|
||
|
capabilities required for Stack Power on
|
||
|
the high-end.
|
||
|
|
||
|
POE - Power Over Ethernet
|
||
|
|
||
|
FEP - Front End Power Supply
|
||
|
|
||
|
SOC - Sustained Overload Condition
|
||
|
|
||
|
GLS - Graceful Load Shedding
|
||
|
|
||
|
ILS - Immediate Load Shedding
|
||
|
|
||
|
SRLS - System Ring Load Shedding
|
||
|
|
||
|
SSLS - System Star Load Shedding"
|
||
|
REVISION "201112120000Z"
|
||
|
DESCRIPTION
|
||
|
"Modified 'cswSwitchRole' object."
|
||
|
REVISION "201002010000Z"
|
||
|
DESCRIPTION
|
||
|
"Added cswStackPowerStatusGroup, cswStackPowerSwitchStatusGroup,
|
||
|
cswStackPowerPortStatusGroup, cswStatusGroupRev1 and
|
||
|
cswStackPowerNotificationGroup.
|
||
|
Deprecated cswStackWiseMIBCompliance compliance statement.
|
||
|
Added cswStackWiseMIBComplianceRev1 compliance statement.
|
||
|
Deprecated cswStatusGroup because we deprecated
|
||
|
cswEnableStackNotifications"
|
||
|
REVISION "200806100000Z"
|
||
|
DESCRIPTION
|
||
|
"Modified 'cswSwitchState' object."
|
||
|
REVISION "200510120000Z"
|
||
|
DESCRIPTION
|
||
|
"Initial version of this MIB module."
|
||
|
::= { ciscoMgmt 500 }
|
||
|
|
||
|
|
||
|
|
||
|
CswPowerStackMode ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This textual convention is used to describe the mode of the
|
||
|
power stack. Since the power stack could only run in either
|
||
|
power sharing or redundant mode so this TC will also have only
|
||
|
following valid values,
|
||
|
powerSharing(1) :When a power stack is running in power
|
||
|
sharing mode then all the power supplies
|
||
|
in the power stack contributes towards
|
||
|
the global power budget of the stack.
|
||
|
|
||
|
redundant(2) :If the user wants the power stack to run
|
||
|
in redundant mode then we will take the
|
||
|
capacity of the largest power supply in
|
||
|
the power stack out of power stack global
|
||
|
power budget pool.
|
||
|
|
||
|
powerSharingStrict(3):This mode is same as power sharing mode
|
||
|
but, in this mode, the available power
|
||
|
will always be more than the used power.
|
||
|
|
||
|
redundantStrict(4) :This mode is same as redundant mode but,
|
||
|
in this mode, the available power will
|
||
|
always be more than the used power."
|
||
|
SYNTAX INTEGER {
|
||
|
powerSharing(1),
|
||
|
redundant(2),
|
||
|
powerSharingStrict(3),
|
||
|
redundantStrict(4)
|
||
|
}
|
||
|
|
||
|
CswPowerStackType ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This textual conventions is used to describe the type of the
|
||
|
power stack. Since the power stack could only be configured in
|
||
|
a ring or star topology so this TC will have only following
|
||
|
valid values,
|
||
|
ring(1): The power stack has been formed by connecting
|
||
|
the switches in ring topology.
|
||
|
star(2): The power stack has been formed by connecting
|
||
|
the switches in star topology."
|
||
|
SYNTAX INTEGER {
|
||
|
ring(1),
|
||
|
star(2)
|
||
|
}
|
||
|
ciscoStackWiseMIBNotifs OBJECT IDENTIFIER
|
||
|
::= { ciscoStackWiseMIB 0 }
|
||
|
|
||
|
ciscoStackWiseMIBObjects OBJECT IDENTIFIER
|
||
|
::= { ciscoStackWiseMIB 1 }
|
||
|
|
||
|
ciscoStackWiseMIBConform OBJECT IDENTIFIER
|
||
|
::= { ciscoStackWiseMIB 2 }
|
||
|
|
||
|
cswGlobals OBJECT IDENTIFIER
|
||
|
::= { ciscoStackWiseMIBObjects 1 }
|
||
|
|
||
|
cswStackInfo OBJECT IDENTIFIER
|
||
|
::= { ciscoStackWiseMIBObjects 2 }
|
||
|
|
||
|
cswStackPowerInfo OBJECT IDENTIFIER
|
||
|
::= { ciscoStackWiseMIBObjects 3 }
|
||
|
|
||
|
|
||
|
-- Textual Conventions
|
||
|
|
||
|
CswSwitchNumber ::= TEXTUAL-CONVENTION
|
||
|
DISPLAY-HINT "d"
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value, greater than zero, for each switch in a group
|
||
|
of stackable switches."
|
||
|
SYNTAX Unsigned32 (1..4294967295)
|
||
|
|
||
|
CswSwitchNumberOrZero ::= TEXTUAL-CONVENTION
|
||
|
DISPLAY-HINT "d"
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value, greater than or equal to zero, for each switch
|
||
|
in a group of stackable switches.
|
||
|
|
||
|
A value of zero means that the switch number can not be
|
||
|
determined. The value of zero is not unique."
|
||
|
SYNTAX Unsigned32 (0..4294967295)
|
||
|
|
||
|
CswSwitchPriority ::= TEXTUAL-CONVENTION
|
||
|
DISPLAY-HINT "d"
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A value, greater than or equal to zero, that defines the
|
||
|
priority of a switch in a group of stackable switches. The
|
||
|
higher the value, the higher the priority."
|
||
|
SYNTAX Unsigned32 (0..4294967295)
|
||
|
|
||
|
-- Global objects pertinent to all switches
|
||
|
|
||
|
cswMaxSwitchNum OBJECT-TYPE
|
||
|
SYNTAX CswSwitchNumber
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum number of switches that can be configured on
|
||
|
this stack. This is also the maximum value that can be
|
||
|
set by the cswSwitchNumNextReload object."
|
||
|
::= { cswGlobals 1 }
|
||
|
|
||
|
cswMaxSwitchConfigPriority OBJECT-TYPE
|
||
|
SYNTAX CswSwitchPriority
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum configurable priority for a switch in this stack.
|
||
|
Highest value equals highest priority. This is the highest
|
||
|
value that can be set by the cswSwitchSwPriority object."
|
||
|
::= { cswGlobals 2 }
|
||
|
|
||
|
cswRingRedundant OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A value of 'true' is returned when the stackports are
|
||
|
connected in such a way that it forms a redundant ring."
|
||
|
::= { cswGlobals 3 }
|
||
|
|
||
|
cswStackPowerInfoTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CswStackPowerInfoEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This table holds the information about all the power stacks in
|
||
|
a single data stack."
|
||
|
::= { cswStackPowerInfo 1 }
|
||
|
|
||
|
cswStackPowerInfoEntry OBJECT-TYPE
|
||
|
SYNTAX CswStackPowerInfoEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An entry in the cswStackPowerInfoTable for each of the power
|
||
|
stacks in a single data stack. This entry contains information
|
||
|
regarding the power stack."
|
||
|
INDEX { cswStackPowerStackNumber }
|
||
|
::= { cswStackPowerInfoTable 1 }
|
||
|
|
||
|
CswStackPowerInfoEntry ::= SEQUENCE {
|
||
|
cswStackPowerStackNumber Unsigned32,
|
||
|
cswStackPowerMode CswPowerStackMode,
|
||
|
cswStackPowerMasterMacAddress MacAddress,
|
||
|
cswStackPowerMasterSwitchNum Unsigned32,
|
||
|
cswStackPowerNumMembers Unsigned32,
|
||
|
cswStackPowerType CswPowerStackType,
|
||
|
cswStackPowerName SnmpAdminString
|
||
|
}
|
||
|
|
||
|
cswStackPowerStackNumber OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value, greater than zero, to identify a power stack."
|
||
|
::= { cswStackPowerInfoEntry 1 }
|
||
|
|
||
|
cswStackPowerMode OBJECT-TYPE
|
||
|
SYNTAX CswPowerStackMode
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object specifies the information about the mode of the
|
||
|
power stack.
|
||
|
Power-sharing mode: All of the input power can be used for
|
||
|
loads, and the total available power appears as one huge power
|
||
|
supply. The power budget includes all power from all supplies.
|
||
|
No power is set aside for power supply failures, so if a power
|
||
|
supply fails, load shedding (shutting down of powered devices or
|
||
|
switches) might occur. This is the default.
|
||
|
Redundant mode: The largest power supply is removed from the
|
||
|
power pool to be used as backup power in case one of the other
|
||
|
power supplies fails. The available power budget is the total
|
||
|
power minus the largest power supply. This reduces the available
|
||
|
power in the pool for switches and powered devices to draw from,
|
||
|
but in case of a failure or an extreme power load, there is less
|
||
|
chance of having to shut down switches or powered devices. This
|
||
|
is the recommended operating mode if your system has enough
|
||
|
power.
|
||
|
In addition, you can configure each mode to run a strict power
|
||
|
budget or a non-strict (loose) power budget. If the mode is
|
||
|
strict, the stack power needs cannot exceed the available power.
|
||
|
When the power budgeted to devices reaches the maximum available
|
||
|
PoE power, power is denied to the next device seeking power. In
|
||
|
this mode the stack never goes into an over-budgeted power mode.
|
||
|
When the mode is non-strict, budgeted power is allowed to exceed
|
||
|
available power. This is normally not a problem because most
|
||
|
devices do not run at full power and the chances of all powered
|
||
|
devices in the stack requiring maximum power at the same time is
|
||
|
small."
|
||
|
::= { cswStackPowerInfoEntry 2 }
|
||
|
|
||
|
cswStackPowerMasterMacAddress OBJECT-TYPE
|
||
|
SYNTAX MacAddress
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the Mac address of the power stack
|
||
|
master."
|
||
|
::= { cswStackPowerInfoEntry 3 }
|
||
|
|
||
|
cswStackPowerMasterSwitchNum OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the switch number of the power stack
|
||
|
master.
|
||
|
The value of this object would be zero if the power stack
|
||
|
master is not part of this data stack."
|
||
|
::= { cswStackPowerInfoEntry 4 }
|
||
|
|
||
|
cswStackPowerNumMembers OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the number of members in the power
|
||
|
stack."
|
||
|
::= { cswStackPowerInfoEntry 5 }
|
||
|
|
||
|
cswStackPowerType OBJECT-TYPE
|
||
|
SYNTAX CswPowerStackType
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the topology of the power stack, that is,
|
||
|
whether the switch is running in RING or STAR topology."
|
||
|
::= { cswStackPowerInfoEntry 6 }
|
||
|
|
||
|
cswStackPowerName OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object specifies a unique name of this power stack. A
|
||
|
zero-length string indicates no name is assigned."
|
||
|
::= { cswStackPowerInfoEntry 7 }
|
||
|
|
||
|
|
||
|
|
||
|
cswStackPowerPortInfoTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CswStackPowerPortInfoEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This table contains information about the stack power ports.
|
||
|
There exists an entry in this table for each physical stack
|
||
|
power port."
|
||
|
::= { cswStackPowerInfo 2 }
|
||
|
|
||
|
cswStackPowerPortInfoEntry OBJECT-TYPE
|
||
|
SYNTAX CswStackPowerPortInfoEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A conceptual row in the cswStackPowerPortInfoTable. This entry
|
||
|
contains information about a power stack port."
|
||
|
INDEX {
|
||
|
entPhysicalIndex,
|
||
|
cswStackPowerPortIndex
|
||
|
}
|
||
|
::= { cswStackPowerPortInfoTable 1 }
|
||
|
|
||
|
CswStackPowerPortInfoEntry ::= SEQUENCE {
|
||
|
cswStackPowerPortIndex Unsigned32,
|
||
|
cswStackPowerPortOperStatus INTEGER,
|
||
|
cswStackPowerPortNeighborMacAddress MacAddress,
|
||
|
cswStackPowerPortNeighborSwitchNum CswSwitchNumberOrZero,
|
||
|
cswStackPowerPortLinkStatus INTEGER,
|
||
|
cswStackPowerPortOverCurrentThreshold Unsigned32,
|
||
|
cswStackPowerPortName SnmpAdminString
|
||
|
}
|
||
|
|
||
|
cswStackPowerPortIndex OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value, greater than zero, for each stack power port."
|
||
|
::= { cswStackPowerPortInfoEntry 1 }
|
||
|
|
||
|
cswStackPowerPortOperStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
enabled(1),
|
||
|
disabled(2)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object is used to either set or unset the operational
|
||
|
status of the stack port. This object will have following valid
|
||
|
values,
|
||
|
|
||
|
enabled(1) : The port is enabled
|
||
|
disabled(2) : The port is forced down"
|
||
|
::= { cswStackPowerPortInfoEntry 2 }
|
||
|
|
||
|
cswStackPowerPortNeighborMacAddress OBJECT-TYPE
|
||
|
SYNTAX MacAddress
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This objects indicates the port neighbor's Mac Address."
|
||
|
::= { cswStackPowerPortInfoEntry 3 }
|
||
|
|
||
|
cswStackPowerPortNeighborSwitchNum OBJECT-TYPE
|
||
|
SYNTAX CswSwitchNumberOrZero
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This objects indicates the port neighbor's switch number. If
|
||
|
either there is no switch connected or the neighbor is not
|
||
|
Jack-Jack then the value of this object is going to be 0."
|
||
|
::= { cswStackPowerPortInfoEntry 4 }
|
||
|
|
||
|
cswStackPowerPortLinkStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
up(1),
|
||
|
down(2)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object is used to describe the link status of the stack
|
||
|
port. This object will have following valid
|
||
|
values,
|
||
|
|
||
|
up(1) : The port is connected and operational
|
||
|
down(2): The port is either forced down or not connected"
|
||
|
::= { cswStackPowerPortInfoEntry 5 }
|
||
|
|
||
|
cswStackPowerPortOverCurrentThreshold OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
UNITS "Amperes"
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object is used to retrieve the over current threshold. The
|
||
|
stack power cables are limited to carry current up to the limit
|
||
|
retrieved by this object. The stack power cables would not be
|
||
|
able to function properly if either the input or output current
|
||
|
goes beyond the threshold retrieved by this object."
|
||
|
::= { cswStackPowerPortInfoEntry 6 }
|
||
|
|
||
|
cswStackPowerPortName OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object specifies a unique name of the stack power port as
|
||
|
shown on the face plate of the system. A zero-length string
|
||
|
indicates no name is assigned."
|
||
|
::= { cswStackPowerPortInfoEntry 7 }
|
||
|
|
||
|
|
||
|
|
||
|
cswEnableStackNotifications OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"This object indicates whether the system generates the
|
||
|
notifications defined in this MIB or not. A value of
|
||
|
'false' will prevent the notifications from being sent."
|
||
|
::= { cswGlobals 4 }
|
||
|
|
||
|
cswEnableIndividualStackNotifications OBJECT-TYPE
|
||
|
SYNTAX BITS {
|
||
|
stackPortChange(0),
|
||
|
stackNewMaster(1),
|
||
|
stackMismatch(2),
|
||
|
stackRingRedundant(3),
|
||
|
stackNewMember(4),
|
||
|
stackMemberRemoved(5),
|
||
|
stackPowerLinkStatusChanged(6),
|
||
|
stackPowerPortOperStatusChanged(7),
|
||
|
stackPowerVersionMismatch(8),
|
||
|
stackPowerInvalidTopology(9),
|
||
|
stackPowerBudgetWarning(10),
|
||
|
stackPowerInvalidInputCurrent(11),
|
||
|
stackPowerInvalidOutputCurrent(12),
|
||
|
stackPowerUnderBudget(13),
|
||
|
stackPowerUnbalancedPowerSupplies(14),
|
||
|
stackPowerInsufficientPower(15),
|
||
|
stackPowerPriorityConflict(16),
|
||
|
stackPowerUnderVoltage(17),
|
||
|
stackPowerGLS(18),
|
||
|
stackPowerILS(19),
|
||
|
stackPowerSRLS(20),
|
||
|
stackPowerSSLS(21),
|
||
|
stackMemberToBeReloadedForUpgrade(22)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object is used to enable/disable individual notifications
|
||
|
defined in this MIB module. Turning on a particular bit would
|
||
|
enable the corresponding trap and, similarly, turning off a
|
||
|
particular bit would disable the corresponding trap. The
|
||
|
following notifications are controlled by this object:
|
||
|
|
||
|
stackPortChange(0): enables/disables cswStackPortChange
|
||
|
notification.
|
||
|
|
||
|
stackNewMaster(1): enables/disables cswStackNewMember
|
||
|
notification.
|
||
|
|
||
|
stackMismatch(2): enables/disables cswStackMismatch
|
||
|
notification.
|
||
|
|
||
|
stackRingRedundant(3): enables/disables cswStackRingRedundant
|
||
|
notification.
|
||
|
|
||
|
stackNewMember(4): enables/disables cswStackNewMember
|
||
|
notification.
|
||
|
|
||
|
stackMemberRemoved(5): enables/disables cswStackMemberRemoved
|
||
|
notification.
|
||
|
|
||
|
stackPowerLinkStatusChanged(6): enables/disables
|
||
|
cswStackPowerPortLinkStatusChanged notification.
|
||
|
|
||
|
stackPowerPortOperStatusChanged(7): enables/disables
|
||
|
cswStackPowerPortOperStatusChanged notification.
|
||
|
|
||
|
stackPowerVersionMismatch(8): enables/disables
|
||
|
cswStackPowerVersionMismatch notification.
|
||
|
|
||
|
stackPowerInvalidTopology(9): enables/disables
|
||
|
cswStackPowerInvalidTopology notification
|
||
|
|
||
|
stackPowerBudgetWarning(10): enables/disables
|
||
|
cswStackPowerBudgetWarning notification.
|
||
|
|
||
|
stackPowerInvalidInputCurrent(11): enables/disables
|
||
|
cswStackPowerInvalidInputCurrent notification.
|
||
|
|
||
|
stackPowerInvalidOutputCurrent(12): enables/disables
|
||
|
cswStackPowerInvalidOutputCurrent notification.
|
||
|
|
||
|
stackPowerUnderBudget(13): enables/disables
|
||
|
cswStackPowerUnderBudget notification.
|
||
|
|
||
|
stackPowerUnbalancedPowerSupplies(14): enables/disables
|
||
|
cswStackPowerUnbalancedPowerSupplies notification.
|
||
|
|
||
|
stackPowerInsufficientPower(15): enables/disables
|
||
|
cswStackPowerInsufficientPower notification.
|
||
|
|
||
|
stackPowerPriorityConflict(16): enables/disables
|
||
|
cswStackPowerPriorityConflict notification.
|
||
|
|
||
|
stackPowerUnderVoltage(17): enables/disables
|
||
|
cswStackPowerUnderVoltage notification.
|
||
|
|
||
|
stackPowerGLS(18): enables/disables cswStackPowerGLS
|
||
|
notification.
|
||
|
|
||
|
stackPowerILS(19): enables/disabled cswStackPowerILS
|
||
|
notification.
|
||
|
|
||
|
stackPowerSRLS(20): enables/disables cswStackPowerSRLS
|
||
|
notification.
|
||
|
|
||
|
stackPowerSSLS(21): enables/disables cswStackPowerSSLS
|
||
|
notification.
|
||
|
stackMemberToBeReloadedForUpgrade(22): enables/disables
|
||
|
cswStackMemberToBeReloadedForUpgrade notification."
|
||
|
::= { cswGlobals 5 }
|
||
|
-- Switch Information Table
|
||
|
|
||
|
cswSwitchInfoTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CswSwitchInfoEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This table contains information specific to switches in a
|
||
|
stack. Every switch with an entry in the entPhysicalTable
|
||
|
(ENTITY-MIB) whose entPhysicalClass is 'chassis' will have
|
||
|
an entry in this table."
|
||
|
::= { cswStackInfo 1 }
|
||
|
|
||
|
cswSwitchInfoEntry OBJECT-TYPE
|
||
|
SYNTAX CswSwitchInfoEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A conceptual row in the cswSwitchInfoTable describing
|
||
|
a switch information."
|
||
|
INDEX { entPhysicalIndex }
|
||
|
::= { cswSwitchInfoTable 1 }
|
||
|
|
||
|
CswSwitchInfoEntry ::= SEQUENCE {
|
||
|
cswSwitchNumCurrent CswSwitchNumber,
|
||
|
cswSwitchNumNextReload CswSwitchNumberOrZero,
|
||
|
cswSwitchRole INTEGER,
|
||
|
cswSwitchSwPriority CswSwitchPriority,
|
||
|
cswSwitchHwPriority CswSwitchPriority,
|
||
|
cswSwitchState INTEGER,
|
||
|
cswSwitchMacAddress MacAddress,
|
||
|
cswSwitchSoftwareImage SnmpAdminString,
|
||
|
cswSwitchPowerBudget Unsigned32,
|
||
|
cswSwitchPowerCommited Unsigned32,
|
||
|
cswSwitchSystemPowerPriority Unsigned32,
|
||
|
cswSwitchPoeDevicesLowPriority Unsigned32,
|
||
|
cswSwitchPoeDevicesHighPriority Unsigned32
|
||
|
}
|
||
|
|
||
|
cswSwitchNumCurrent OBJECT-TYPE
|
||
|
SYNTAX CswSwitchNumber
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object contains the current switch identification number.
|
||
|
This number should match any logical labeling on the switch.
|
||
|
For example, a switch whose interfaces are labeled
|
||
|
'interface #3' this value should be 3."
|
||
|
::= { cswSwitchInfoEntry 1 }
|
||
|
|
||
|
cswSwitchNumNextReload OBJECT-TYPE
|
||
|
SYNTAX CswSwitchNumberOrZero
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object contains the cswSwitchNumCurrent to be
|
||
|
used at next reload. The maximum value for this object is
|
||
|
defined by the cswMaxSwitchNum object.
|
||
|
|
||
|
Note: This object will contain 0 and cannot be set if the
|
||
|
cswSwitchState value is other than 'ready'."
|
||
|
::= { cswSwitchInfoEntry 2 }
|
||
|
|
||
|
cswSwitchRole OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
master(1),
|
||
|
member(2),
|
||
|
notMember(3),
|
||
|
standby(4)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object describes the function of the switch:
|
||
|
|
||
|
master - stack master.
|
||
|
|
||
|
member - active member of the stack.
|
||
|
|
||
|
notMember - none-active stack member, see
|
||
|
cswSwitchState for status.
|
||
|
|
||
|
standby - stack standby switch."
|
||
|
::= { cswSwitchInfoEntry 3 }
|
||
|
|
||
|
cswSwitchSwPriority OBJECT-TYPE
|
||
|
SYNTAX CswSwitchPriority
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A number containing the priority of a switch. The switch with
|
||
|
the highest priority will become the master. The maximum value
|
||
|
for this object is defined by the cswMaxSwitchConfigPriority
|
||
|
object.
|
||
|
|
||
|
If after a reload the value of cswMaxSwitchConfigPriority
|
||
|
changes to a smaller value, and the value of cswSwitchSwPriority
|
||
|
has been previously set to a value greater or equal to the
|
||
|
new cswMaxSwitchConfigPriority, then the SNMP agent must set
|
||
|
cswSwitchSwPriority to the new cswMaxSwitchConfigPriority.
|
||
|
|
||
|
Note: This object will contain the value of 0 if the
|
||
|
cswSwitchState value is other than 'ready'."
|
||
|
::= { cswSwitchInfoEntry 4 }
|
||
|
|
||
|
cswSwitchHwPriority OBJECT-TYPE
|
||
|
SYNTAX CswSwitchPriority
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object contains the hardware priority of a switch. If
|
||
|
two or more entries in this table have the same
|
||
|
cswSwitchSwPriority value during the master election time,
|
||
|
the switch with the highest cswSwitchHwPriority will become
|
||
|
the master.
|
||
|
|
||
|
Note: This object will contain the value of 0 if the
|
||
|
cswSwitchState value is other than 'ready'."
|
||
|
::= { cswSwitchInfoEntry 5 }
|
||
|
|
||
|
cswSwitchState OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
waiting(1),
|
||
|
progressing(2),
|
||
|
added(3),
|
||
|
ready(4),
|
||
|
sdmMismatch(5),
|
||
|
verMismatch(6),
|
||
|
featureMismatch(7),
|
||
|
newMasterInit(8),
|
||
|
provisioned(9),
|
||
|
invalid(10),
|
||
|
removed(11)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The current state of a switch:
|
||
|
|
||
|
waiting - Waiting for a limited time on other
|
||
|
switches in the stack to come online.
|
||
|
|
||
|
progressing - Master election or mismatch checks in
|
||
|
progress.
|
||
|
|
||
|
added - The switch is added to the stack.
|
||
|
|
||
|
ready - The switch is operational.
|
||
|
|
||
|
sdmMismatch - The SDM template configured on the master
|
||
|
is not supported by the new member.
|
||
|
|
||
|
verMismatch - The operating system version running on the
|
||
|
master is different from the operating
|
||
|
system version running on this member.
|
||
|
|
||
|
featureMismatch - Some of the features configured on the
|
||
|
master are not supported on this member.
|
||
|
|
||
|
newMasterInit - Waiting for the new master to finish
|
||
|
initialization after master switchover
|
||
|
(Master Re-Init).
|
||
|
|
||
|
provisioned - The switch is not an active member of the
|
||
|
stack.
|
||
|
|
||
|
invalid - The switch's state machine is in an
|
||
|
invalid state.
|
||
|
|
||
|
removed - The switch is removed from the stack."
|
||
|
::= { cswSwitchInfoEntry 6 }
|
||
|
|
||
|
cswSwitchMacAddress OBJECT-TYPE
|
||
|
SYNTAX MacAddress
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The MAC address of the switch.
|
||
|
|
||
|
Note: This object will contain the value of 0000:0000:0000
|
||
|
if the cswSwitchState value is other than 'ready'."
|
||
|
::= { cswSwitchInfoEntry 7 }
|
||
|
|
||
|
cswSwitchSoftwareImage OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The software image type running on the switch.
|
||
|
|
||
|
Note: This object will contain an empty string if the
|
||
|
cswSwitchState value is other than 'ready'."
|
||
|
::= { cswSwitchInfoEntry 8 }
|
||
|
|
||
|
cswSwitchPowerBudget OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
UNITS "Watts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the power budget of the switch."
|
||
|
::= { cswSwitchInfoEntry 9 }
|
||
|
|
||
|
cswSwitchPowerCommited OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
UNITS "Watts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the power committed to the POE devices
|
||
|
connected to the switch."
|
||
|
::= { cswSwitchInfoEntry 10 }
|
||
|
|
||
|
cswSwitchSystemPowerPriority OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This specifies the system's power priority. In case of
|
||
|
a power failure then the system with the highest system
|
||
|
priority will be brought down last."
|
||
|
::= { cswSwitchInfoEntry 11 }
|
||
|
|
||
|
cswSwitchPoeDevicesLowPriority OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object specifies the priority of the system's low
|
||
|
priority POE devices."
|
||
|
::= { cswSwitchInfoEntry 12 }
|
||
|
|
||
|
cswSwitchPoeDevicesHighPriority OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object specifies the priority of the system's high
|
||
|
priority POE devices. In order to avoid losing the high
|
||
|
priority POE devices before the low priority POE devices,
|
||
|
this object's value must be greater than value of
|
||
|
cswSwitchPoeDevicesLowPriority."
|
||
|
::= { cswSwitchInfoEntry 13 }
|
||
|
|
||
|
|
||
|
-- StackPort Information Table
|
||
|
|
||
|
cswStackPortInfoTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CswStackPortInfoEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This table contains stackport specific information. There
|
||
|
exists an entry in this table for every physical stack
|
||
|
port that have an entry in the ifTable (IF-MIB)."
|
||
|
::= { cswStackInfo 2 }
|
||
|
|
||
|
cswStackPortInfoEntry OBJECT-TYPE
|
||
|
SYNTAX CswStackPortInfoEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A conceptual row in the cswStackPortInfoTable. An entry
|
||
|
contains information about a stackport."
|
||
|
INDEX { ifIndex }
|
||
|
::= { cswStackPortInfoTable 1 }
|
||
|
|
||
|
CswStackPortInfoEntry ::= SEQUENCE {
|
||
|
cswStackPortOperStatus INTEGER,
|
||
|
cswStackPortNeighbor EntPhysicalIndexOrZero
|
||
|
}
|
||
|
|
||
|
cswStackPortOperStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
up(1),
|
||
|
down(2),
|
||
|
forcedDown(3)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The state of the stackport.
|
||
|
|
||
|
up - Connected and operational.
|
||
|
|
||
|
down - Not connected to a neighboring switch or
|
||
|
administrative down.
|
||
|
|
||
|
forcedDown - Shut down by stack manager due to mismatch or
|
||
|
stackport errors."
|
||
|
::= { cswStackPortInfoEntry 1 }
|
||
|
|
||
|
cswStackPortNeighbor OBJECT-TYPE
|
||
|
SYNTAX EntPhysicalIndexOrZero
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object contains the value of the entPhysicalIndex of the
|
||
|
switch's chassis to which this stackport is connected to. If
|
||
|
the stackport is not connected, the value 0 is returned."
|
||
|
::= { cswStackPortInfoEntry 2 }
|
||
|
|
||
|
|
||
|
-- Notifications
|
||
|
|
||
|
cswMIBNotifications OBJECT IDENTIFIER
|
||
|
::= { ciscoStackWiseMIBNotifs 0 }
|
||
|
|
||
|
|
||
|
cswStackPortChange NOTIFICATION-TYPE
|
||
|
OBJECTS {
|
||
|
ifIndex,
|
||
|
cswStackPortOperStatus,
|
||
|
cswSwitchNumCurrent
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the state
|
||
|
of a stack port has changed."
|
||
|
::= { cswMIBNotifications 1 }
|
||
|
|
||
|
cswStackNewMaster NOTIFICATION-TYPE
|
||
|
OBJECTS { cswSwitchNumCurrent }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when a new master has been
|
||
|
elected. The notification will contain the cswSwitchNumCurrent
|
||
|
object to indicate the new master ID."
|
||
|
::= { cswMIBNotifications 2 }
|
||
|
|
||
|
cswStackMismatch NOTIFICATION-TYPE
|
||
|
OBJECTS {
|
||
|
cswSwitchState,
|
||
|
cswSwitchNumCurrent
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when a new member attempt
|
||
|
to join the stack but was denied due to a mismatch. The
|
||
|
cswSwitchState object will indicate the type of mismatch."
|
||
|
::= { cswMIBNotifications 3 }
|
||
|
|
||
|
cswStackRingRedundant NOTIFICATION-TYPE
|
||
|
OBJECTS { cswRingRedundant }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the redundancy of the
|
||
|
ring has changed."
|
||
|
::= { cswMIBNotifications 4 }
|
||
|
|
||
|
cswStackNewMember NOTIFICATION-TYPE
|
||
|
OBJECTS { cswSwitchNumCurrent }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when a new member joins the
|
||
|
stack."
|
||
|
::= { cswMIBNotifications 5 }
|
||
|
|
||
|
cswStackMemberRemoved NOTIFICATION-TYPE
|
||
|
OBJECTS { cswSwitchNumCurrent }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when a member is removed
|
||
|
from the stack."
|
||
|
::= { cswMIBNotifications 6 }
|
||
|
|
||
|
cswStackPowerPortLinkStatusChanged NOTIFICATION-TYPE
|
||
|
OBJECTS {
|
||
|
cswStackPowerPortLinkStatus,
|
||
|
cswSwitchNumCurrent,
|
||
|
cswStackPowerPortName
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the link status of a stack
|
||
|
power port is changed from up to down or down to up. This
|
||
|
notification is for informational purposes only and no action
|
||
|
is required. cswStackPowerPortLinkStatus indicates link status
|
||
|
of the stack power ports. cswSwitchNumCurrent indicates the
|
||
|
switch number of the system. cswStackPowerPortName specifies a
|
||
|
unique name of the stack power port as shown on the face plate
|
||
|
of the system."
|
||
|
::= { cswMIBNotifications 7 }
|
||
|
|
||
|
cswStackPowerPortOperStatusChanged NOTIFICATION-TYPE
|
||
|
OBJECTS {
|
||
|
cswSwitchNumCurrent,
|
||
|
cswStackPowerPortOperStatus,
|
||
|
cswStackPowerPortName
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the operational status of a
|
||
|
stack power port is changed from enabled to disabled or from
|
||
|
disabled to enabled. This notification is for informational
|
||
|
purposes only and no action is required. cswSwitchNumCurrent
|
||
|
indicates the switch number of the system.
|
||
|
cswStackPowerPortOperStatus indicates operational status
|
||
|
of the stack power ports. cswStackPowerPortName specifies
|
||
|
a unique name of the stack power port as shown on the face
|
||
|
plate of the system."
|
||
|
::= { cswMIBNotifications 8 }
|
||
|
|
||
|
cswStackPowerVersionMismatch NOTIFICATION-TYPE
|
||
|
OBJECTS { cswSwitchNumCurrent }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the major version of the
|
||
|
stack power protocol is different from the other members of the
|
||
|
power stack. Upon receiving this notification, the user should
|
||
|
make sure that he/she is using the same software version on all
|
||
|
the members of the same power stack. cswSwitchNumCurrent
|
||
|
indicates the switch number of the system seeing the power
|
||
|
stack version mismatch."
|
||
|
::= { cswMIBNotifications 9 }
|
||
|
|
||
|
cswStackPowerInvalidTopology NOTIFICATION-TYPE
|
||
|
OBJECTS { cswSwitchNumCurrent }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when an invalid stack power
|
||
|
topology is discovered by a switch. cswSwitchNumCurrent
|
||
|
indicates the switch number of the system where the invalid
|
||
|
topology is discovered."
|
||
|
::= { cswMIBNotifications 10 }
|
||
|
|
||
|
cscwStackPowerBudgetWarrning NOTIFICATION-TYPE
|
||
|
OBJECTS { cswSwitchNumCurrent }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the switch power budget is
|
||
|
more than 1000W above its power supplies rated power output.
|
||
|
cswSwitchNumCurrent indicates the switch number of the system
|
||
|
where the invalid power budget has been detected."
|
||
|
::= { cswMIBNotifications 11 }
|
||
|
|
||
|
cswStackPowerInvalidInputCurrent NOTIFICATION-TYPE
|
||
|
OBJECTS {
|
||
|
cswSwitchNumCurrent,
|
||
|
cswStackPowerPortOverCurrentThreshold,
|
||
|
cswStackPowerPortName
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the input current in the
|
||
|
stack power cable is over the limit of the threshold retrieved
|
||
|
by the agent through cswStackPowerPortOverCurrentThreshold
|
||
|
object. Upon receiving this notification, the user should add a
|
||
|
power supply to the system whose switch number is generated
|
||
|
with this notification. cswSwitchNumCurrent
|
||
|
indicates the switch number of the system.
|
||
|
cswStackPowerPortOverCurrentThreshold indicates the over current
|
||
|
threshold of power stack cables. cswStackPowerPortName specifies
|
||
|
a unique name of the stack power port as shown on the face
|
||
|
plate of the system."
|
||
|
::= { cswMIBNotifications 12 }
|
||
|
|
||
|
cswStackPowerInvalidOutputCurrent NOTIFICATION-TYPE
|
||
|
OBJECTS {
|
||
|
cswSwitchNumCurrent,
|
||
|
cswStackPowerPortOverCurrentThreshold,
|
||
|
cswStackPowerPortName
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the output current in the
|
||
|
stack power cable is over the limit of the threshold retrieved
|
||
|
by the agent through cswStackPowerPortOverCurrentThreshold
|
||
|
object. Upon receiving this notification, the user should
|
||
|
remove a power supply from the system whose switch number is
|
||
|
generated with this notification. cswSwitchNumCurrent
|
||
|
indicates the switch number of the system.
|
||
|
cswStackPowerPortOverCurrentThreshold indicates the over current
|
||
|
threshold of power stack cables. cswStackPowerPortName specifies
|
||
|
a unique name of the stack power port as shown on the face
|
||
|
plate of the system."
|
||
|
::= { cswMIBNotifications 13 }
|
||
|
|
||
|
cswStackPowerUnderBudget NOTIFICATION-TYPE
|
||
|
OBJECTS { cswSwitchNumCurrent }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the switch's budget is less
|
||
|
than maximum possible switch power consumption.
|
||
|
cswSwitchNumCurrent indicates the switch number of the system
|
||
|
that is running with the power budget less than the power
|
||
|
consumption."
|
||
|
::= { cswMIBNotifications 14 }
|
||
|
|
||
|
cswStackPowerUnbalancedPowerSupplies NOTIFICATION-TYPE
|
||
|
OBJECTS { cswStackPowerName }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the switch has no power
|
||
|
supply but another switch in the same stack has more than one
|
||
|
power supplies. cswStackPowerName specifies a unique name of the
|
||
|
power stack where the unbalanced power supplies are detected."
|
||
|
::= { cswMIBNotifications 15 }
|
||
|
|
||
|
cswStackPowerInsufficientPower NOTIFICATION-TYPE
|
||
|
OBJECTS { cswStackPowerName }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the switch's power stack
|
||
|
does not have enough power to bring up all the switches in the
|
||
|
power stack. cswStackPowerName specifies a unique name of the
|
||
|
power stack where insufficient power condition is detected."
|
||
|
::= { cswMIBNotifications 16 }
|
||
|
|
||
|
cswStackPowerPriorityConflict NOTIFICATION-TYPE
|
||
|
OBJECTS { cswStackPowerName }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the switch's power
|
||
|
priorities are conflicting with power priorities of another
|
||
|
switch in the same power stack. cswStackPowerPortName specifies
|
||
|
the unique name of the power stack where the conflicting power
|
||
|
priorities are detected."
|
||
|
::= { cswMIBNotifications 17 }
|
||
|
|
||
|
cswStackPowerUnderVoltage NOTIFICATION-TYPE
|
||
|
OBJECTS { cswSwitchNumCurrent }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the switch had an under
|
||
|
voltage condition on last boot up. cswSwitchNumCurrent
|
||
|
indicates the switch number of the system that was forced
|
||
|
down with the under voltage condition."
|
||
|
::= { cswMIBNotifications 18 }
|
||
|
|
||
|
cswStackPowerGLS NOTIFICATION-TYPE
|
||
|
OBJECTS { cswSwitchNumCurrent }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the switch had to shed
|
||
|
loads based on a sustained over load (SOC) condition.
|
||
|
cswSwitchNumCurrent indicates the switch number of the system
|
||
|
that goes through graceful load shedding."
|
||
|
::= { cswMIBNotifications 19 }
|
||
|
|
||
|
cswStackPowerILS NOTIFICATION-TYPE
|
||
|
OBJECTS { cswSwitchNumCurrent }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the switch had to shed
|
||
|
loads based on power supply fail condition. cswSwitchNumCurrent
|
||
|
indicates the switch number of the system that goes through
|
||
|
immediate load shedding."
|
||
|
::= { cswMIBNotifications 20 }
|
||
|
|
||
|
cswStackPowerSRLS NOTIFICATION-TYPE
|
||
|
OBJECTS { cswSwitchNumCurrent }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the switch had to shed
|
||
|
loads based on loss of a system in ring topology.
|
||
|
cswSwitchNumCurrent indicates the switch number of the system
|
||
|
that detects the loss of system in ring topology."
|
||
|
::= { cswMIBNotifications 21 }
|
||
|
|
||
|
cswStackPowerSSLS NOTIFICATION-TYPE
|
||
|
OBJECTS { cswSwitchNumCurrent }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when the switch had to shed
|
||
|
loads based on loss of a system in star topology.
|
||
|
cswSwitchNumCurrent indicates the switch number of the system
|
||
|
that detects the loss of system in star topology."
|
||
|
::= { cswMIBNotifications 22 }
|
||
|
|
||
|
cswStackMemberToBeReloadedForUpgrade NOTIFICATION-TYPE
|
||
|
OBJECTS { cswSwitchNumCurrent }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This notification is generated when a member is to be reloaded
|
||
|
for upgrade."
|
||
|
::= { cswMIBNotifications 23 }
|
||
|
-- Conformance and Compliance statements
|
||
|
|
||
|
cswStackWiseMIBCompliances OBJECT IDENTIFIER
|
||
|
::= { ciscoStackWiseMIBConform 1 }
|
||
|
|
||
|
cswStackWiseMIBGroups OBJECT IDENTIFIER
|
||
|
::= { ciscoStackWiseMIBConform 2 }
|
||
|
|
||
|
|
||
|
cswStackWiseMIBCompliance MODULE-COMPLIANCE
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The compliance statement for entities that implement the
|
||
|
CISCO-STACKWISE-MIB."
|
||
|
MODULE -- this module
|
||
|
MANDATORY-GROUPS {
|
||
|
cswStatusGroup,
|
||
|
cswNotificationGroup
|
||
|
}
|
||
|
|
||
|
OBJECT cswSwitchSwPriority
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required."
|
||
|
|
||
|
OBJECT cswSwitchNumNextReload
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required."
|
||
|
::= { cswStackWiseMIBCompliances 1 }
|
||
|
|
||
|
cswStackWiseMIBComplianceRev1 MODULE-COMPLIANCE
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The compliance statements for entities described in
|
||
|
CISCO-STACKWISE-MIB. Stack Power entities are added in this
|
||
|
revision."
|
||
|
MODULE -- this module
|
||
|
MANDATORY-GROUPS {
|
||
|
cswNotificationGroup,
|
||
|
cswStatusGroupRev1,
|
||
|
cswStackPowerEnableNotificationGroup
|
||
|
}
|
||
|
|
||
|
GROUP cswStackPowerStatusGroup
|
||
|
DESCRIPTION
|
||
|
"This group is only mandatory for systems which support stack
|
||
|
power."
|
||
|
|
||
|
GROUP cswStackPowerSwitchStatusGroup
|
||
|
DESCRIPTION
|
||
|
"This group is only mandatory for systems which support stack
|
||
|
power."
|
||
|
|
||
|
GROUP cswStackPowerPortStatusGroup
|
||
|
DESCRIPTION
|
||
|
"This group is only mandatory for systems which support stack
|
||
|
power."
|
||
|
|
||
|
GROUP cswStackPowerNotificationGroup
|
||
|
DESCRIPTION
|
||
|
"This group is only mandatory for systems which support stack
|
||
|
power."
|
||
|
::= { cswStackWiseMIBCompliances 2 }
|
||
|
|
||
|
cswStackWiseMIBComplianceRev2 MODULE-COMPLIANCE
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The compliance statements for entities described in
|
||
|
CISCO-STACKWISE-MIB. Stack Power entities are added in this
|
||
|
revision."
|
||
|
MODULE -- this module
|
||
|
MANDATORY-GROUPS {
|
||
|
cswNotificationGroup,
|
||
|
cswNotificationGroupSup1,
|
||
|
cswStatusGroupRev1,
|
||
|
cswStackPowerEnableNotificationGroup
|
||
|
}
|
||
|
|
||
|
GROUP cswStackPowerStatusGroup
|
||
|
DESCRIPTION
|
||
|
"This group is only mandatory for systems which support stack
|
||
|
power."
|
||
|
|
||
|
GROUP cswStackPowerSwitchStatusGroup
|
||
|
DESCRIPTION
|
||
|
"This group is only mandatory for systems which support stack
|
||
|
power."
|
||
|
|
||
|
GROUP cswStackPowerPortStatusGroup
|
||
|
DESCRIPTION
|
||
|
"This group is only mandatory for systems which support stack
|
||
|
power."
|
||
|
|
||
|
GROUP cswStackPowerNotificationGroup
|
||
|
DESCRIPTION
|
||
|
"This group is only mandatory for systems which support stack
|
||
|
power."
|
||
|
::= { cswStackWiseMIBCompliances 3 }
|
||
|
|
||
|
-- units of conformance
|
||
|
|
||
|
cswStatusGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
cswMaxSwitchNum,
|
||
|
cswMaxSwitchConfigPriority,
|
||
|
cswRingRedundant,
|
||
|
cswEnableStackNotifications,
|
||
|
cswSwitchNumCurrent,
|
||
|
cswSwitchNumNextReload,
|
||
|
cswSwitchRole,
|
||
|
cswSwitchSwPriority,
|
||
|
cswSwitchHwPriority,
|
||
|
cswSwitchState,
|
||
|
cswSwitchMacAddress,
|
||
|
cswSwitchSoftwareImage,
|
||
|
cswStackPortOperStatus,
|
||
|
cswStackPortNeighbor,
|
||
|
cswStackPowerType
|
||
|
}
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"A collection of objects that are used for control and
|
||
|
status."
|
||
|
::= { cswStackWiseMIBGroups 1 }
|
||
|
|
||
|
cswNotificationGroup NOTIFICATION-GROUP
|
||
|
NOTIFICATIONS {
|
||
|
cswStackPortChange,
|
||
|
cswStackNewMaster,
|
||
|
cswStackMismatch,
|
||
|
cswStackRingRedundant,
|
||
|
cswStackNewMember,
|
||
|
cswStackMemberRemoved
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A collection of notifications that are required."
|
||
|
::= { cswStackWiseMIBGroups 2 }
|
||
|
|
||
|
cswStatusGroupRev1 OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
cswMaxSwitchNum,
|
||
|
cswMaxSwitchConfigPriority,
|
||
|
cswRingRedundant,
|
||
|
cswSwitchNumCurrent,
|
||
|
cswSwitchNumNextReload,
|
||
|
cswSwitchRole,
|
||
|
cswSwitchSwPriority,
|
||
|
cswSwitchHwPriority,
|
||
|
cswSwitchState,
|
||
|
cswSwitchMacAddress,
|
||
|
cswSwitchSoftwareImage
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A collection of objects that are used for control and
|
||
|
status."
|
||
|
::= { cswStackWiseMIBGroups 3 }
|
||
|
|
||
|
cswStackPowerStatusGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
cswStackPowerMode,
|
||
|
cswStackPowerMasterMacAddress,
|
||
|
cswStackPowerMasterSwitchNum,
|
||
|
cswStackPowerNumMembers,
|
||
|
cswStackPowerType,
|
||
|
cswStackPowerName
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A collection of stack power objects that are used for control
|
||
|
and status of power stack."
|
||
|
::= { cswStackWiseMIBGroups 4 }
|
||
|
|
||
|
cswStackPowerSwitchStatusGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
cswSwitchPowerBudget,
|
||
|
cswSwitchPowerCommited,
|
||
|
cswSwitchSystemPowerPriority,
|
||
|
cswSwitchPoeDevicesLowPriority,
|
||
|
cswSwitchPoeDevicesHighPriority
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A collection of stack power objects that are used to track the
|
||
|
stack power parameters of a switch."
|
||
|
::= { cswStackWiseMIBGroups 5 }
|
||
|
|
||
|
cswStackPowerPortStatusGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
cswStackPowerPortOperStatus,
|
||
|
cswStackPowerPortNeighborMacAddress,
|
||
|
cswStackPowerPortNeighborSwitchNum,
|
||
|
cswStackPowerPortLinkStatus,
|
||
|
cswStackPowerPortOverCurrentThreshold,
|
||
|
cswStackPowerPortName
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A collection of objects that are used for control and status of
|
||
|
stack power ports."
|
||
|
::= { cswStackWiseMIBGroups 6 }
|
||
|
|
||
|
cswStackPowerNotificationGroup NOTIFICATION-GROUP
|
||
|
NOTIFICATIONS {
|
||
|
cswStackPowerPortLinkStatusChanged,
|
||
|
cswStackPowerPortOperStatusChanged,
|
||
|
cswStackPowerVersionMismatch,
|
||
|
cswStackPowerInvalidTopology,
|
||
|
cscwStackPowerBudgetWarrning,
|
||
|
cswStackPowerInvalidInputCurrent,
|
||
|
cswStackPowerInvalidOutputCurrent,
|
||
|
cswStackPowerUnderBudget,
|
||
|
cswStackPowerUnbalancedPowerSupplies,
|
||
|
cswStackPowerInsufficientPower,
|
||
|
cswStackPowerPriorityConflict,
|
||
|
cswStackPowerUnderVoltage,
|
||
|
cswStackPowerGLS,
|
||
|
cswStackPowerILS,
|
||
|
cswStackPowerSRLS,
|
||
|
cswStackPowerSSLS
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A collection of notifications that are triggered whenever there
|
||
|
is either a change in stack power object or an error is
|
||
|
encountered."
|
||
|
::= { cswStackWiseMIBGroups 7 }
|
||
|
|
||
|
cswStackPowerEnableNotificationGroup OBJECT-GROUP
|
||
|
OBJECTS { cswEnableIndividualStackNotifications }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This group contains the notification enable objects for this
|
||
|
MIB."
|
||
|
::= { cswStackWiseMIBGroups 8 }
|
||
|
|
||
|
cswNotificationGroupSup1 NOTIFICATION-GROUP
|
||
|
NOTIFICATIONS { cswStackMemberToBeReloadedForUpgrade }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Additional notification required for data stack."
|
||
|
::= { cswStackWiseMIBGroups 9 }
|
||
|
|
||
|