From ef504e62c5310b5dade197b3f1be11587d43c182 Mon Sep 17 00:00:00 2001 From: Ingo Wetzel Date: Thu, 13 Dec 2018 09:54:34 +0100 Subject: [PATCH] =?UTF-8?q?Erg=C3=A4nzungen=20MIBs?= MIME-Version: 1.0 Content-Type: text/plain; charset=UTF-8 Content-Transfer-Encoding: 8bit --- MIBs/CISCO-SMI.my | 566 + MIBs/CISCO-TC.my | 2669 ++ MIBs/CISCO-VTP-MIB.my | 6521 ++++ MIBs/anx_mib_121.txt | 4445 +++ MIBs/aruba-wlan.my | 5938 ++++ MIBs/dell-wlan.my | 143 + MIBs/netbotz300.txt | 8803 +++++ MIBs/powernet412_mib.txt | 70998 +++++++++++++++++++++++++++++++++++++ 8 files changed, 100083 insertions(+) create mode 100644 MIBs/CISCO-SMI.my create mode 100644 MIBs/CISCO-TC.my create mode 100644 MIBs/CISCO-VTP-MIB.my create mode 100644 MIBs/anx_mib_121.txt create mode 100644 MIBs/aruba-wlan.my create mode 100644 MIBs/dell-wlan.my create mode 100644 MIBs/netbotz300.txt create mode 100644 MIBs/powernet412_mib.txt diff --git a/MIBs/CISCO-SMI.my b/MIBs/CISCO-SMI.my new file mode 100644 index 0000000..3c5de65 --- /dev/null +++ b/MIBs/CISCO-SMI.my @@ -0,0 +1,566 @@ +-- ***************************************************************** +-- CISCO-SMI.my: Cisco Enterprise Structure of Management Information +-- +-- April 1994, Jeffrey T. Johnson +-- +-- Copyright (c) 1994-1997, 2001, 2009, 2012, 2016 by cisco Systems Inc. +-- All rights reserved. +-- +-- **************************************************************** + +CISCO-SMI DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, + OBJECT-IDENTITY, + enterprises + FROM SNMPv2-SMI; + + +cisco MODULE-IDENTITY + LAST-UPDATED "201601150000Z" + ORGANIZATION "Cisco Systems, Inc." + CONTACT-INFO + "Cisco Systems + Customer Service + + Postal: 170 West Tasman Drive + San Jose, CA 95134 + USA + + Tel: +1 800 553-NETS + + E-mail: cs-snmp@cisco.com" + DESCRIPTION + "The Structure of Management Information for the + Cisco enterprise." + REVISION "201601150000Z" + DESCRIPTION + "Added ciscoLDAP under cisco" + REVISION "201208290000Z" + DESCRIPTION + "Added ciscoSMB under otherEnterprises" + REVISION "200902030000Z" + DESCRIPTION + "Added ciscoSB under otherEnterprises" + REVISION "200203210000Z" + DESCRIPTION + "Added ciscoPKI for PKI policy and extension OIDs" + REVISION "200105220000Z" + DESCRIPTION + "Added transport protocol domains." + REVISION "200011012246Z" + DESCRIPTION + "Added ciscoDomains to define new transports. Also added + ciscoCpeCIB, which will contain managed objects that + contribute to the CPE Configuration Information Base (CIB)." + REVISION "200001110000Z" + DESCRIPTION + "Added ciscoPolicy, ciscoPolicyAuto, ciscoPIB, and + ciscoPibToMib." + REVISION "9704090000Z" + DESCRIPTION + "Added ciscoPartnerProducts to generate sysObjectID + for partner platforms" + REVISION "9505160000Z" + DESCRIPTION + "New oid assignments for Cisco REPEATER MIB and others." + REVISION "9404262000Z" + DESCRIPTION + "Initial version of this MIB module." + ::= { enterprises 9 } + + + +-- assigned by IANA + +ciscoProducts OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoProducts is the root OBJECT IDENTIFIER from + which sysObjectID values are assigned. Actual + values are defined in CISCO-PRODUCTS-MIB." + ::= { cisco 1 } + + +local OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Subtree beneath which pre-10.2 MIBS were built." + ::= { cisco 2 } + + +temporary OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Subtree beneath which pre-10.2 experiments were + placed." + ::= { cisco 3 } + + +pakmon OBJECT-IDENTITY + STATUS current + DESCRIPTION + "reserved for pakmon" + ::= { cisco 4 } + + +workgroup OBJECT-IDENTITY + STATUS current + DESCRIPTION + "subtree reserved for use by the Workgroup Business Unit" + ::= { cisco 5 } + + +otherEnterprises OBJECT-IDENTITY + STATUS current + DESCRIPTION + "otherEnterprises provides a root object identifier + from which mibs produced by other companies may be + placed. mibs produced by other enterprises are + typicially implemented with the object identifiers + as defined in the mib, but if the mib is deemed to + be uncontrolled, we may reroot the mib at this + subtree in order to have a controlled version." + ::= { cisco 6 } + + +ciscoSB OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoSB provides root Object Identifier for Management + Information Base for products of Cisco Small Business. + This includes products rebranded from linksys aquisition. + MIB numbers under this root are managed and controlled + by ciscosb_mib@cisco.com." + ::= { otherEnterprises 1 } + + +ciscoSMB OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoSMB provides root Object Identifier for Management + Information Base for products of Cisco built for Small and + Medium Business market.The MIB numbers under this root are + managed and controlled by ciscosmb_mib@cisco.com" + ::= { otherEnterprises 2 } + + +ciscoAgentCapability OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoAgentCapability provides a root object identifier + from which AGENT-CAPABILITIES values may be assigned." + ::= { cisco 7 } + + +ciscoConfig OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoConfig is the main subtree for configuration mibs." + ::= { cisco 8 } + + +ciscoMgmt OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoMgmt is the main subtree for new mib development." + ::= { cisco 9 } + + +ciscoExperiment OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoExperiment provides a root object identifier + from which experimental mibs may be temporarily + based. mibs are typicially based here if they + fall in one of two categories + 1) are IETF work-in-process mibs which have not + been assigned a permanent object identifier by + the IANA. + 2) are cisco work-in-process which has not been + assigned a permanent object identifier by the + cisco assigned number authority, typicially because + the mib is not ready for deployment. + + NOTE WELL: support for mibs in the ciscoExperiment + subtree will be deleted when a permanent object + identifier assignment is made." + ::= { cisco 10 } + + +ciscoAdmin OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoAdmin is reserved for administratively assigned + OBJECT IDENTIFIERS, i.e. those not associated with MIB + objects" + ::= { cisco 11 } + + +ciscoModules OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoModules provides a root object identifier + from which MODULE-IDENTITY values may be assigned." + ::= { cisco 12 } + + +lightstream OBJECT-IDENTITY + STATUS current + DESCRIPTION + "subtree reserved for use by Lightstream" + ::= { cisco 13 } + + +ciscoworks OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoworks provides a root object identifier beneath + which mibs applicable to the CiscoWorks family of network + management products are defined." + ::= { cisco 14 } + + +newport OBJECT-IDENTITY + STATUS current + DESCRIPTION + "subtree reserved for use by the former Newport Systems + Solutions, now a portion of the Access Business Unit." + ::= { cisco 15 } + + +ciscoPartnerProducts OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoPartnerProducts is the root OBJECT IDENTIFIER from + which partner sysObjectID values may be assigned. Such + sysObjectID values are composed of the ciscoPartnerProducts + prefix, followed by a single identifier that is unique for + each partner, followed by the value of sysObjectID of the + Cisco product from which partner product is derived. Note + that the chassisPartner MIB object defines the value of the + identifier assigned to each partner." + ::= { cisco 16 } + + +ciscoPolicy OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoPolicy is the root of the Cisco-assigned OID + subtree for use with Policy Management." + ::= { cisco 17 } + + +-- Note that 1.3.6.1.4.1.9.17.1 is currently unassigned + +ciscoPIB OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoPIB is the root of the Cisco-assigned OID + subtree for assignment to PIB (Policy Information + Base) modules." + ::= { ciscoPolicy 2 } + + +ciscoPolicyAuto OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoPolicyAuto is the root of the Cisco-assigned + OID subtree for OIDs which are automatically assigned + for use in Policy Management." + ::= { cisco 18 } + + +-- Note that 1.3.6.1.4.1.9.18.1 is currently unassigned + +ciscoPibToMib OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoPibToMib is the root of the Cisco-assigned + OID subtree for MIBs which are algorithmically + generated/translated from Cisco PIBs with OIDs + assigned under the ciscoPIB subtree. + These generated MIBs allow management + entities (other the current Policy Server) to + read the downloaded policy. By convention, for PIB + 'ciscoPIB.x', the generated MIB shall have the + name 'ciscoPibToMib.x'." + ::= { ciscoPolicyAuto 2 } + + +ciscoDomains OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoDomains provides a root object identifier from which + different transport mapping values may be assigned." + ::= { cisco 19 } + + +ciscoCIB OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoCIB is the root of the Cisco-assigned OID subtree for + assignment to MIB modules describing managed objects that + part of the CPE automatic configuration framework." + ::= { cisco 20 } + + +ciscoCibMmiGroup OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoCibMmiGroup is the root of the Cisco-assigned OID + subtree for assignment to MIB modules describing managed + objects supporting the Modem Management Interface (MMI), + the interface that facilitates CPE automatic configuration." + ::= { ciscoCIB 1 } + + +ciscoCibProvGroup OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoCibStoreGroup is the root of the Cisco-assigned OID + subtree for assignment to MIB modules describing managed + objects contributing to the Configuration Information Base + (CIB)." + ::= { ciscoCIB 2 } + + +ciscoPKI OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoPKI is the root of cisco-assigned OID subtree for PKI + Certificate Policies and Certificate Extensions." + ::= { cisco 21 } + + +ciscoLDAP OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoLDAP is the root of the Cisco-assigned OID + subtree for assignment to LDAP (Lightweight Directory + Access Protocol) modules." + ::= { cisco 22 } + + +-- ciscoAdmin assignments follow + +ciscoProxy OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoProxy OBJECT IDENTIFIERS are used to uniquely name + party mib records created to proxy for SNMPv1." + ::= { ciscoAdmin 1 } + +ciscoPartyProxy OBJECT IDENTIFIER + ::= { ciscoProxy 1 } + +ciscoContextProxy OBJECT IDENTIFIER + ::= { ciscoProxy 2 } + + +-- Administrative assignments for repeaters + +ciscoRptrGroupObjectID OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ciscoRptrGroupObjectID OBJECT IDENTIFIERS are used to + uniquely identify groups of repeater ports for use by the + SNMP-REPEATER-MIB (RFC 1516) rptrGroupObjectID object." + ::= { ciscoAdmin 2 } + + +ciscoUnknownRptrGroup OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The identity of an unknown repeater port group." + ::= { ciscoRptrGroupObjectID 1 } + + +cisco2505RptrGroup OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The authoritative identity of the Cisco 2505 repeater + port group." + ::= { ciscoRptrGroupObjectID 2 } + + +cisco2507RptrGroup OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The authoritative identity of the Cisco 2507 repeater + port group." + ::= { ciscoRptrGroupObjectID 3 } + + +cisco2516RptrGroup OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The authoritative identity of the Cisco 2516 repeater + port group." + ::= { ciscoRptrGroupObjectID 4 } + + +ciscoWsx5020RptrGroup OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The authoritative identity of the wsx5020 repeater + port group." + ::= { ciscoRptrGroupObjectID 5 } + + +-- Administrative assignments for chip sets + +ciscoChipSets OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Numerous media-specific MIBS have an object, defined as + an OBJECT IDENTIFIER, which is the identity of the chipset + realizing the interface. Cisco-specific chipsets have their + OBJECT IDENTIFIERS assigned under this subtree." + ::= { ciscoAdmin 3 } + + +ciscoChipSetSaint1 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The identity of the Rev 1 SAINT ethernet chipset + manufactured for cisco by LSI Logic." + ::= { ciscoChipSets 1 } + + +ciscoChipSetSaint2 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The identity of the Rev 2 SAINT ethernet chipset + manufactured for cisco by LSI Logic." + ::= { ciscoChipSets 2 } + + +ciscoChipSetSaint3 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The identity of the Rev 3 SAINT ethernet chipset + manufactured for cisco by Plessey." + ::= { ciscoChipSets 3 } + + +ciscoChipSetSaint4 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The identity of the Rev 4 SAINT ethernet chipset + manufactured for cisco by Mitsubishi." + ::= { ciscoChipSets 4 } + +-- Transport protocol domains +-- +-- The textual conventions for these domains are defined in CISCO-TM. + +ciscoTDomains OBJECT IDENTIFIER + ::= { ciscoDomains 99999 } + + +ciscoTDomainUdpIpv4 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The UDP over IPv4 transport domain. The corresponding + transport address is of type CiscoTAddressIPv4." + ::= { ciscoTDomains 1 } + + +ciscoTDomainUdpIpv6 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The UDP over IPv6 transport domain. The corresponding + transport address is of type CiscoTAddressIPv6 for global IPv6 + addresses and CiscoTAddressIPv6s for scoped IPv6 addresses." + ::= { ciscoTDomains 2 } + + +ciscoTDomainTcpIpv4 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The TCP over IPv4 transport domain. The corresponding + transport address is of type CiscoTAddressIPv4." + ::= { ciscoTDomains 3 } + + +ciscoTDomainTcpIpv6 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The TCP over IPv6 transport domain. The corresponding + transport address is of type CiscoTAddressIPv6 for global IPv6 + addresses and CiscoTAddressIPv6s for scoped IPv6 addresses." + ::= { ciscoTDomains 4 } + + +ciscoTDomainLocal OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Posix Local IPC transport domain. The corresponding + transport address is of type CiscoTAddressLocal. The Posix + Local IPC transport domain incorporates the well known UNIX + domain sockets." + ::= { ciscoTDomains 5 } + + +ciscoTDomainClns OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The CLNS transport domain. The corresponding transport + address is of type CiscoTAddressOSI." + ::= { ciscoTDomains 6 } + + +ciscoTDomainCons OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The CONS transport domain. The corresponding transport + address is of type CiscoTAddressOSI." + ::= { ciscoTDomains 7 } + + +ciscoTDomainDdp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The DDP transport domain. The corresponding transport + address is of type CiscoTAddressNBP." + ::= { ciscoTDomains 8 } + + +ciscoTDomainIpx OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The IPX transport domain. The corresponding transport + address is of type CiscoTAddressIPX." + ::= { ciscoTDomains 9 } + + +ciscoTDomainSctpIpv4 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The SCTP over IPv4 transport domain. The corresponding + transport address is of type CiscoTAddressIPv4." + REFERENCE + "RFC 2960 - Stream Control Transmission Protocol. R. Stewart, + Q. Xie, K. Morneault, C. Sharp, H. Schwarzbauer, T. Taylor, + I. Rytina, M. Kalla, L. Zhang, V. Paxson. October 2000." + ::= { ciscoTDomains 10 } + + +ciscoTDomainSctpIpv6 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The SCTP over IPv6 transport domain. The corresponding + transport address is of type CiscoTAddressIPv6 for global IPv6 + addresses and CiscoTAddressIPv6s for scoped IPv6 addresses." + REFERENCE + "RFC 2960 - Stream Control Transmission Protocol. R. Stewart, + Q. Xie, K. Morneault, C. Sharp, H. Schwarzbauer, T. Taylor, + I. Rytina, M. Kalla, L. Zhang, V. Paxson. October 2000." + ::= { ciscoTDomains 11 } + + +END + + diff --git a/MIBs/CISCO-TC.my b/MIBs/CISCO-TC.my new file mode 100644 index 0000000..610abd3 --- /dev/null +++ b/MIBs/CISCO-TC.my @@ -0,0 +1,2669 @@ +-- ***************************************************************** +-- CISCO-TC.my: Cisco MIB Textual Conventions +-- +-- May 1994, Jeffrey T. Johnson +-- +-- Copyright (c) 1994-2015 and by Cisco Systems Inc. +-- All rights reserved. +-- +-- *************************************************************** + +CISCO-TC DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, + Gauge32, + Integer32, + Unsigned32, + Counter64 + FROM SNMPv2-SMI + TEXTUAL-CONVENTION + FROM SNMPv2-TC + ciscoModules + FROM CISCO-SMI; + + +ciscoTextualConventions MODULE-IDENTITY + LAST-UPDATED "201506090000Z" + ORGANIZATION "Cisco Systems, Inc." + CONTACT-INFO + "Cisco Systems + Customer Service + + Postal: 170 W Tasman Drive + San Jose, CA 95134 + USA + + Tel: +1 800 553-NETS + + E-mail: cs-snmp@cisco.com" + DESCRIPTION + "This module defines textual conventions used throughout + cisco enterprise mibs." + REVISION "201506090000Z" + DESCRIPTION + "Added the following enumerations for IfOperStatusReason: + physicalPortHotStandBy, + wimaxModemUnattached, + wpanModemUnattached, + rbhModulo, + fpcMinLinkNotMet, + misCabling, + rcvSrpOnNonFcoeFex, + acessPortOnBd, + lacpMisConfig, + fortyGMemberPort, + goldLoopBackTest, + edpError, + vpcCompCheckFailed, + aclQosNoResource, + vpcShutdown, + notPcMember, + systemIntfShut, + speedGroupConfigMisMatch, + dot1qMisConfig, + mdMisMatch, + vpcPeerLinkShut, + notAvailable" + REVISION "201407230000Z" + DESCRIPTION + "-Added the textual-convention CiscoAbsZeroBasedCounter64." + REVISION "201208060000Z" + DESCRIPTION + "-Added the following enums for IfOperStatusReason: + ficonNoPortSwapLogicalPort, + ficonInvalidPortNum, + remotePortInL2vpnDown, + suspendedDueToNoLacpPdus, + fcotValidationFailedAtDriver, + unsupportedTransceiverMd5DigestNotSame, + unsupportedTransceiver, + adminStateConfigChange, + vlanAllowedList, + vlanAllowedListOverride, + vlanAllowedListAdd, + vlanAllowedRemove, + vlanCfgStateChange, + vlanCfgDelete, + pppPeerNotResponding, + pppAuthFailed, + xcvrAuthFailed, + badFramesRcvdFromLink" + REVISION "201202010000Z" + DESCRIPTION + "Added CiscoVlanIndex TC." + REVISION "201111110000Z" + DESCRIPTION + "Added CiscoEntityIndexList TC." + REVISION "201106170000Z" + DESCRIPTION + "-Added the following enums for FcIfOperStatusReason: + fcRedirectIsolation, + portActLicenseNotAvailable, + sdmIsolation, + fcidAllocationFailed, + unavailableNPVUpstreamPort, + unavailableNPVPrefUpstreamPort, + sfpReadError, + stickyDownOnLinkFailure, + tooManyLinkFlapsErr, + unidirectionalUDLD, + txRxLoopUDLD, + neighborMismatchUDLD, + authzPending, + hotStdbyInBundle, + incompleteConfig, + incompleteTunnelCfg, + hwProgrammingFailed, + tunnelDstUnreachable, + suspendByMtu, + sfpInvalid, + sfpAbsent, + portCapabilitiesUnknown, + channelErrDisabled, + vrfMismatch, + vrfForwardReferencing, + dupTunnelConfigDetected, + primaryVLANDown, + vrfUnusable, + errDisableHandShkFailure, + errDisabledBPDUGuard, + dot1xSecViolationErrDisabled, + emptyEchoUDLD, + vfTaggingCapErr, + portDisabled, + tunnelModeNotConfigured, + tunnelSrcNotConfigured, + tunnelDstNotConfigured, + tunnelUnableToResolveSrcIP + tunnelUnableToResolveDstIP, + tunnelVrfDown, + sifAdminDown, + phyIntfDown, + ifSifLimitExceeded, + sifHoldDown, + noFcoe, + dcxCompatMismatch, + isolateBundleLimitExceeded, + sifNotBound, + errDisabledLacpMiscfg, + satFabricIfDown, + invalidSatFabricIf, + noRemoteChassis, + vicEnableNotReceived, + vicDisableReceived, + vlanVsanMappingNotEnabled, + stpNotFwdingInFcoeMappedVlan, + moduleOffline, + udldAggModeLinkFailure, + stpInconsVpcPeerDisabled, + setPortStateFailed, + suspendedByVpc, + vpcCfgInProgress, + vpcPeerLinkDown, + vpcNoRspFromPeer, + protoPortSuspend, + tunnelSrcDown, + cdpInfoUnavailable, + fexSfpInvalid, + errDisabledIpConflict, + fcotClkRateMismatch, + portGuardTrustSecViolation, + sdpTimeout, + satIncompatTopo, + waitForFlogi, + satNotConfigured, + npivNotEnabledInUpstream, + vsanMismatchWithUpstreamSwPort, + portGuardBitErrRate, + portGuardSigLoss, + portGuardSyncLoss, + portGuardLinkReset, + portGuardCreditLoss, + bitErrorRate, + signalLoss, + syncLoss, + linkReset, + creditLoss, + ipQosMgrPolicyAppFailure, + pauseRateLimitErrDisabled, + lstGrpUplinkDown, + stickyDnLinkFailure, + routerMacFailure, + dcxMultipleMsapIds, + dcxHundredPdusRcvdNoAck, + enmSatIncompatibleUplink, + enmLoopDetected, + nonStickyExternallyDisabled, + subGroupIdNotAssigned, + vemUnlicensed, + profileNotFound, + nonExistentVlan, + vlanInvalidType, + vlanDown, + vpcPeerUpgrade, + ipQosDcbxpCompatFailure, + nonCiscoHbaVfTag, + domainIdConfigMismatch, + sfpSpeedMismatch, + xcvrInitializing, + xcvrAbsent, + xcvrInvalid, + vfcBindingInvalid, + vlanNotFcoeEnabled, + pvlanNativeVlanErr, + ethL2VlanDown, + ethIntfInvalidBinding, + pmonFailure, + l3NotReady, + speedMismatch, + flowControlMismatch, + vdcMode, + suspendedDueToMinLinks, + enmPinFailLinkDown, + inactiveM1PortFpathActiveVlan, + parentPortDown, + moduleRemoved, + corePortMct, + nonCorePortMct, + ficonInorderNotActive, + invalidEncapsulation, + modemLineDeasserted, + ipSecHndshkInProgress, + sfpEthCompliantErr, + cellularModemUnattached, + outOfGlblRxBuffers, + sfpFcCompliantErr, + ethIntfNotLicensed, + domainIdsInvalid, + fabricNameInvalid." + REVISION "201002240000Z" + DESCRIPTION + "Added CiscoURLStringOrEmpty textual convention." + REVISION "200906180000Z" + DESCRIPTION + "Added the new textual convention CiscoVrfName" + REVISION "200903100000Z" + DESCRIPTION + "Added the new textual convention CiscoInterfaceIndexList" + REVISION "200902260000Z" + DESCRIPTION + "Added the new textual convention Cisco2KVlanList" + REVISION "200804020000Z" + DESCRIPTION + "Added the new textual convention CiscoBridgeDomain." + REVISION "200702150000Z" + DESCRIPTION + "Added following textual conventions: + CiscoVlanList, + CiscoCosList, + CiscoPbbServiceIdentifier" + REVISION "200607060000Z" + DESCRIPTION + "Added the following enums to IfOperStatusReason: + - elpFailureAllZeroPeerWWNRcvd, + - preferredPathIsolation." + REVISION "200604130000Z" + DESCRIPTION + "Added enumeration to IfOperStatusReason from 113-131 + ('dpvmVsanSuspended' to 'domainOther')." + REVISION "200506240000Z" + DESCRIPTION + "Added CvE164Address textual convention." + REVISION "200506160000Z" + DESCRIPTION + "Added following textual conventions: + CiscoURLString + CiscoHTTPResponseStatusCode + EntLogicalIndexOrZero." + REVISION "200410110000Z" + DESCRIPTION + "Added IfOperStatusReason textual convention." + REVISION "200406080000Z" + DESCRIPTION + "Added CiscoPortListRange textual convention." + REVISION "200404140000Z" + DESCRIPTION + "Added CiscoPortList textual convention. + Removed Unsigned32 textual convention." + REVISION "200212180000Z" + DESCRIPTION + "Changed MilliSeconds TC to CiscoMilliSeconds as it was + overlapping with the one in a standard MIB." + REVISION "200212121600Z" + DESCRIPTION + "Added the 'http' enumeration to CiscoNetworkProtocol." + REVISION "200212020000Z" + DESCRIPTION + "Added Unsigned64 textual convention." + REVISION "200209220000Z" + DESCRIPTION + "Added ListIndex, ListIndexOrZero, TimeIntervalSec, + TimeintervalMin, MicroSeconds and MicroSeconds TC from + Andiamo's TC MIB ." + REVISION "200209170000Z" + DESCRIPTION + "Added ConfigIterator & BulkConfigResult textual + convention for bulk provisioning. + Added CountryCodeITU textual convention for ITU-T defined + country codes for non-standard facilities." + REVISION "200204160000Z" + DESCRIPTION + "Added PerfHighIntervalCount TEXTUAL-CONVENTION." + REVISION "200107070000Z" + DESCRIPTION + "Added enumerations to CiscoNetworkProtocol" + REVISION "200101180000Z" + DESCRIPTION + "Added CiscoAlarmSeverity textual convention. + Changed SAPType display hint to d. Changed + INTEGER to Integer32 in CiscoPort and + CiscoIpProtocol TCs. Changed SnmpAdminString + to OCTET STRING in CiscoLocationSpecifier. + Removed IMPORTs for ciscoProducts and + SnmpAdminString." + REVISION "200011210000Z" + DESCRIPTION + "Added CiscoLocationClass, CiscoLocationSpecifier + CiscoInetAddressMask, CiscoAbsZeroBasedCounter32, + CiscoSnapShotAbsCounter32 textual conventions." + REVISION "9810280000Z" + DESCRIPTION + "Added CiscoRowOperStatus, EntPhysicalIndexOrZero, + Port and IpProtocol textual conventions." + REVISION "9703130000Z" + DESCRIPTION + "Added SAPType, CountryCode textual convention." + REVISION "9608140000Z" + DESCRIPTION + "Added InterfaceIndexOrZero textual convention." + REVISION "9607080000Z" + DESCRIPTION + "Added new CiscoNetworkProtocol enumerations." + REVISION "9602220000Z" + DESCRIPTION + "Added Unsigned32 textual conventions." + REVISION "9506070000Z" + DESCRIPTION + "Miscellaneous updates/corrections, including making + CiscoNetworkProtocol enumerations contiguous." + ::= { ciscoModules 1 } + + + +Layer2Cos ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An integer that is in the range of the layer 2 CoS values. It + corresponds to the IEEE 802.1P CoS value which defines eight + (2^3) user priority levels. + Note: the IEEE 802.1P has been merged into IEEE 802.1D." + + REFERENCE + "IEEE 802.1D, 2004 Edition, Annex G User priorities and traffic + classes." + SYNTAX Integer32 (0..7) + +CiscoNetworkProtocol ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Represents the different types of network layer protocols." + SYNTAX INTEGER { + ip(1), + decnet(2), + pup(3), + chaos(4), + xns(5), + x121(6), + appletalk(7), + clns(8), + lat(9), + vines(10), + cons(11), + apollo(12), + stun(13), + novell(14), + qllc(15), + snapshot(16), + atmIlmi(17), + bstun(18), + x25pvc(19), + ipv6(20), + cdm(21), + nbf(22), + bpxIgx(23), + clnsPfx(24), + http(25), + unknown(65535) + } + +CiscoNetworkAddress ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Represents a network layer address. The length and format of + the address is protocol dependent as follows: + ip 4 octets + decnet 2 octets + pup obsolete + chaos 2 octets + xns 10 octets + first 4 octets are the net number + last 6 octets are the host number + x121 + appletalk 3 octets + first 2 octets are the net number + last octet is the host number + clns + lat + vines 6 octets + first 4 octets are the net number + last 2 octets are the host number + cons + apollo 10 octets + first 4 octets are the net number + last 6 octets are the host number + stun 8 octets + novell 10 octets + first 4 octets are the net number + last 6 octets are the host number + qllc 6 octets + bstun 1 octet - bi-sync serial tunnel + snapshot 1 octet + atmIlmi 4 octets + x25 pvc 2 octets (12 bits) + ipv6 16 octets + cdm + nbf + bgpIgx + clnsPfx upto 20 octets + http upto 70 octets + first 4 octets are the IPv4 host + address + next 2 octets are the TCP port + number + remaining(1 upto 64) octets are + the URI" + SYNTAX OCTET STRING + +Unsigned64 ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An unsigned 64 bit integer. We use SYNTAX Counter64 for the + encoding rules." + SYNTAX Counter64 + +InterfaceIndexOrZero ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Either the value 0, or the ifIndex value of an + interface in the ifTable." + SYNTAX Integer32 (0..2147483647) + +SAPType ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Service Access Point - is a term that denotes the means + by which a user entity in layer n+1 accesses a service + of a provider entity in layer n." + SYNTAX Integer32 (0..254) + +CountryCode ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Represents a case-insensitive 2-letter country code taken + from ISO-3166. Unrecognized countries are represented as + empty string." + SYNTAX OCTET STRING (SIZE (0 | 2)) + +CountryCodeITU ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This textual convention represents a country or area code for + non-standard facilities in telematic services." + + REFERENCE "ITU-T T.35 - Section 3.1 Country Code" + SYNTAX Unsigned32 (0..255) + +EntPhysicalIndexOrZero ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This textual convention is an extension of entPhysicalIndex. + If non-zero, the object is an entPhysicalIndex. If zero, no + appropriate entPhysicalIndex exists. Any additional semantics + are object specific." + SYNTAX Integer32 (0..2147483647) + +CiscoRowOperStatus ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Represents the operational status of an table entry. + This textual convention allows explicitly representing + the states of rows dependent on rows in other tables. + + active(1) - + Indicates this entry's RowStatus is active + and the RowStatus for each dependency is active. + + activeDependencies(2) - + Indicates that the RowStatus for each dependency + is active, but the entry's RowStatus is not active. + + inactiveDependency(3) - + Indicates that the RowStatus for at least one + dependency is not active. + + missingDependency(4) - + Indicates that at least one dependency does + not exist in it's table." + SYNTAX INTEGER { + active(1), + activeDependencies(2), + inactiveDependency(3), + missingDependency(4) + } + +CiscoPort ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The TCP or UDP port number range." + + REFERENCE + "Transmission Control Protocol. J. Postel. RFC793, + User Datagram Protocol. J. Postel. RFC768" + SYNTAX Integer32 (0..65535) + +CiscoIpProtocol ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "IP protocol number range." + + REFERENCE "Internet Protocol. J. Postel. RFC791" + SYNTAX Integer32 (0..255) + +CiscoLocationClass ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An enumerated value which provides an indication of + the general location type of a particular physical and/or + logical interface. + chassis - a system framework for mounting one or more + shelves/slots/cards. + shelf - a cabinet that holds one or more slots. + slot - card or subSlot holder. + subSlot - daughter-card holder. + port - a physical port (e.g., a DS1 or DS3 physical port). + subPort - a logical port on a physical port (e.g., a DS1 + subPort on a DS3 physical port). + channel - a logical interface (e.g., a DS0 channel, signaling + channel, ATM port, other virtual interfaces). + subChannel - a sub-channel on a logical interface." + SYNTAX INTEGER { + chassis(1), + shelf(2), + slot(3), + subSlot(4), + port(5), + subPort(6), + channel(7), + subChannel(8) + } + +CiscoLocationSpecifier ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Use this TC to define objects that indicate the + physical entity and/or logical interface location + of a managed entity on a managed device. In SNMP, a + standard mechanism for indicating the physical location + of entities is via the ENTITY-MIB. However, that approach + is not satisfactory in some cases because: + + 1. The entity requiring a location-based naming may be + associated with an entity which can not be represented + as a physical entity in the ENTITY-MIB, + 2. NMS applications may desire a more direct + name/representation of a physical entity than is + available via the ENTITY-MIB, e.g., a physical entity + which is named via a hierarchy of levels in the ENTITY-MIB. + + The value of an object defined using this TC is an ASCII + string consisting of zero or more elements separated by + commas. Each element is of the form = . + + An example of this syntax is 'slot=5,port=3'. + + The syntax of the string is formally specified using + ABNF notation (with one exception, noted below), as + follows: + + location-specifier = elem *(',' elem) + ; subject to + ; size restriction specified in the SYNTAX + ; clause below + + elem = loctype '=' number + + number = %x00-FFFFFFFF / %d0-4294967295 + + loctype = 1*32VCHAR + + It is recommended that loctype use one of the enumerated + labels defined for CiscoLocationClass. + + (NOTE: To conform to ABNF notation as defined in RFC2234, + substitute the single-quote symbol with a double-quote + symbol in the above rules.) + + A zero length of CiscoLocationSpecifier is object-specific + and must be defined as part of the description of any object + which uses this syntax." + + REFERENCE + "RFC2234, Augmented BNF for syntax specifications: ABNF" + SYNTAX OCTET STRING (SIZE (0..255)) + +CiscoInetAddressMask ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Denotes a generic Internet subnet address mask. + The Internet subnet address mask is represented as the + number of contiguous 1-bit from MSB (most significant bit) + of the Internet subnet address mask. + A CiscoInetAddressMask value is always interpreted within + the context of an InetAddressType value. The + InetAddressType only object or InetAddressType with + InetAddress objects which define the context must be + registered immediately before the object which uses the + CiscoInetAddressMask textual convention. In other words, + the object identifiers for the InetAddressType object and + the CiscoInetAddressMask object MUST have the same length + and the last sub-identifier of the InetAddressType object + MUST be 1 less than the last sub-identifier of the + CiscoInetAddressMask object and MUST be 2 less than the + last sub-identifier of the CiscoInetAddressMask object if + an InetAddress object is defined between InetAddressType + and CiscoInetAddressMask objects. + The maximum value of the CiscoInetAddressMask TC is 32 for + the value 'ipv4(1)' in InetAddressType object and 128 for + the value 'ipv6(2)' in InetAddressType object. + The value zero is object-specific and must therefore be + defined as part of the description of any object which + uses this syntax. Examples of the usage of zero might + include situations where Internet subnet mask was unknown, + or when none subnet masks need to be referenced." + + REFERENCE + "RFC2851, Textual Conventions for Internet Network Addresses." + SYNTAX Unsigned32 (0..128) + +CiscoAbsZeroBasedCounter32 ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This TC describes an object which counts events with the + following semantics: objects of this type will be set to + zero(0) on creation and will thereafter count appropriate + events, it locks at the maximum value of 4,294,967,295 if + the counter overflows. + This TC may be used only in situations where wrapping is + not possible or extremely unlikely situation." + SYNTAX Gauge32 + +CiscoSnapShotAbsCounter32 ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This TC describes an object which stores a snap-shot value + with the following semantics: objects of this type will + take a snap-shot value from their associated + CiscoAbsZeroBasedCounter32 type objects on creation." + SYNTAX Unsigned32 + +CiscoAlarmSeverity ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Represents the perceived alarm severity associated + with a service or safety affecting condition and/or + event. These are based on ITU severities, except + that info(7) is added. + + cleared(1) - + Indicates a previous alarm condition has been + cleared. It is not required (unless specifically + stated elsewhere on a case by case basis) that an + alarm condition that has been cleared will produce + a notification or other event containing an + alarm severity with this value. + + indeterminate(2) - + Indicates that the severity level cannot be + determined. + + critical(3) - + Indicates that a service or safety affecting + condition has occurred and an immediate + corrective action is required. + + major(4) - + Indicates that a service affecting condition has + occurred and an urgent corrective action is + required. + + minor(5) - + Indicates the existence of a non-service affecting + condition and that corrective action should be + taken in order to prevent a more serious (for + example, service or safety affecting) condition. + + warning(6) - + Indicates the detection of a potential or impending + service or safety affecting condition, before any + significant effects have been felt. + + info(7) - + Indicates an alarm condition that does not + meet any other severity definition. This can + include important, but non-urgent, notices or + informational events." + + REFERENCE "ITU-X.733" + SYNTAX INTEGER { + cleared(1), + indeterminate(2), + critical(3), + major(4), + minor(5), + warning(6), + info(7) + } + +PerfHighIntervalCount ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "A 64 bit counter associated with a + performance measurement in a previous + 15 minute measurement interval. In the + case where the agent has no valid data + available for a particular interval the + corresponding object instance is not + available and upon a retrieval request + a corresponding error message shall be + returned to indicate that this instance + does not exist (for example, a noSuchName + error for SNMPv1 and a noSuchInstance for + SNMPv2 GET operation). + In a system supporting + a history of n intervals with + IntervalCount(1) and IntervalCount(n) the + most and least recent intervals + respectively, the following applies at + the end of a 15 minute interval: + - discard the value of IntervalCount(n) + - the value of IntervalCount(i) becomes that + of IntervalCount(i-1) for n >= i > 1 + - the value of IntervalCount(1) becomes that + of CurrentCount + - the TotalCount, if supported, is adjusted. + + This definition is based on CounterBasedGauge64 TEXTUAL + CONVENTION defined in RFC2856. The PerfHighIntervalCount + type represents a non-negative + integer, which may increase or decrease, but shall never + exceed a maximum value, nor fall below a minimum value. The + maximum value can not be greater than 2^64-1 + (18446744073709551615 decimal), and the minimum value can + not be smaller than 0. The value of a PerfHighIntervalCount, + has its maximum value whenever the information being modeled + is greater than or equal to its maximum value, and has its + minimum value whenever the information being modeled is + smaller than or equal to its minimum value. If the + information being modeled subsequently decreases below + (increases above) the maximum (minimum) value, the + PerfHighIntervalCount also decreases (increases). + + Note that this TC is not strictly supported in SMIv2, + because the 'always increasing' and 'counter wrap' semantics + associated with the Counter64 base type are not preserved. + It is possible that management applications which rely + solely upon the (Counter64) ASN.1 tag to determine object + semantics will mistakenly operate upon objects of this type + as they would for Counter64 objects. + + This textual convention represents a limited and short-term + solution, and may be deprecated as a long term solution is + defined and deployed to replace it." + + REFERENCE + "RFC 2856(HCNUM-TC MIB). + RFC 2493(PerfHist-TC-MIB)." + SYNTAX Counter64 + +ConfigIterator ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This object type is a control object type which applies to + writable objects in the same SNMP PDU related to the + same table containing those objects. It controls an + operation which repeatedly applies the specified + configuration data to more than one rows in a table. + The operation starts from the row specified by the index + of the instance and repeats for the number of rows as + the value of the object. + + ConfigIterator object needs to be accompanied by one set of + writable objects which are of the same instance to apply to. + + For example, a SNMP PDU contains + { objectA.10 = 1, + objectB.10 = 'E1', + objectC.10 = 44, + objectRepetition.10 = 100 } + + The SYNTAX of objectRepetition is ConfigIterator. + This will apply value 1 to objectA, value 'E1' to objectB, + value 44 to objectC in the table starting from row 10 + repeatedly for 100 rows. + + The iteration is based on the number of rows, not based on + the value of the index. For sparse tables, the index 10, + 20, 30, 110, and 120 counts for 5 rows, the operation will + go beyond index 100 in the previous SNMP PDU example. + + The iteration will stop prematurely when it comes to the + following situations: + (1) When the number of the rows in the table is less than + the designated row indicated by the ConfigIterator + object. + (2) When it encounters the first error in any row, the + operation won't continue to next row. + + The operation of ConfigIterator object applies only to + the writable objects having the same index as the + ConfigIterator object in one SNMP PDU. + + For example, a SNMP PDU contains + { objectD.5 = 38, + objectE.6 = 'T1', + objectF.5 = 'false', + objectIterator.5 = 10 } + + The SYNTAX of objectIterator is ConfigIterator. + This will apply value 38 to objectD, value 'false' to + objectF in the table starting from row 5 repeatedly + for 10 rows. Since the object objectE.6 has different + index (6) from the index of objectIterator, the + repetition won't be applied to it. However the value + of objectE in the row 6 will be set to 'T1' according + to regular SNMP SET orperation. + + If there is row overlapping of the iteration in a SNMP PDU, + it will be operated as they are in two different SNMP PDUs. + + For example, a SNMP PDU contains + { objectD.5 = 38, + objectD.6 = 40, + objectE.6 = 'T1', + objectF.5 = 'false', + objectIterator.5 = 10 + objectIterator.6 = 10 } + + This will apply value 38 to objectD, value 'false' to + objectF starting from row 5 repeatedly for 10 rows, and + apply value 40 to objectD, value 'T1' to objectE starting + from row 6 repeatedly for 10 rows. The final value of + objectD.6 can be 38 or 40, it depends on the SNMP stack of + the system starts SNMP SET for the row 5 before the row 6 + or the other way around. + + The object defined as ConfigIterator will be set to value 1 + after the iteration operation is kick-off regardless the + system has completed the operation to the designated rows + or not. Therefore retrieving the value of this object + is meaningless. It acts as the one time operation for + bulk configuration. + + The object defined as ConfigIterator has no meaning by itself, + it has to be combined with one or more than one writable + objects from the same table and within the same SNMP PDU + for the repetition operation. + + For example, a SNMP PDU contains + { objectG.2 = 49, + objectH.2 = 'AE'h + objectIterator.4 = 20 } + + The SYNTAX of objectIterator is ConfigIterator. Since + there are no objects having the same index as the index + of objectIterator in the PDU, the result of this SNMP + operation will set value 49 to objectG and value 0xAE + to objectH of the row 2 only as regular SNMP SET operation. + + The index of the instance indicates the starting row for the + iteration. + The order of the iteration depends, for instance, on: + (1) physical hardware position, or + (2) logical index. + + It depends on the characters of the table which contains + the ConfigIterator object. + + Iteration can be done through some or all the components + of the index for a table. The description of the iterator + object in that table should describe which part of the + index the iteration is applied to. + + The operation for this object type is based on the best + effort. When the agent receives a SNMP PDU containing this + data type, the return status of the SNMP request reflects + only the result of the SET operation has applied to the + starting row. It may return a SNMP response with SUCCESS + status regardless the number of rows for the data actually + been deployed later on. Therefore it is possible the data + might not be completely deployed to the number of rows + designated by the ConfigIterator and the operation stops + prematurely due to an error it first encounters after + n rows (n < the value of ConfigIterator object). + + Usually the error report mechanism for this type of operation + is accomplished by combining this type of object with the + other two objects in the same table: + + (1) An OwnerString object + (2) An object indicates the result of the operation. + + When issuing this bulk configuration request, the SNMP + manager should provide its identifier in (1) object. + After issuing the request, it should check the value of (1) + object if it is the same with it own name. + If they are the same, then the value of the object presents + in (2) is the result from the previous operation from this + manager. Otherwise, another SNMP manager might issue + the bulk configuration to the same table before the previous + bulk operation has been completed. These two objects will + represent the last bulk operation in the table." + SYNTAX Unsigned32 (1..4294967295) + +BulkConfigResult ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This textual convention defines the format of the + displayable textual result from the bulk configuration + operation specified as ConfigIterator type. + + The format should be: + 'COMPLETION= error occured>/, + ERROR=/: + ' + + For example: + 'COMPLETION=22/100,ERROR=38/44:Invalid Ds1 line coding + for the line type'" + SYNTAX OCTET STRING (SIZE (0..255)) + +ListIndex ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "A unique value greater than zero, for each of the + list that is defined. The object using this + convention should give all the object specific + details including the list type." + SYNTAX Integer32 (1..2147483647) + +ListIndexOrZero ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This textual convention is an extension of the + ListIndex. In addition to the ListIndex range, + this also includes 0 in its range of values. + This value could be object specific and + should be given the description of that object. + In most cases, a value 0 means that the it does + not represent any lists." + SYNTAX Integer32 (0..2147483647) + +TimeIntervalSec ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "A period of time, measured in units of 1 second." + SYNTAX Unsigned32 + +TimeIntervalMin ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "A period of time, measured in units of 1 minute." + SYNTAX Unsigned32 + +CiscoMilliSeconds ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Represents time unit value in milliseconds." + SYNTAX Unsigned32 + +MicroSeconds ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Represents time unit value in microseconds." + SYNTAX Unsigned32 + +CiscoPortList ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Each octet within this value specifies a set of eight + ports. The object defined by this textual convention + can specify a port range of 2k ports in its description. + Example: 1 - 2048, 2049 - 4096, etc. The first octet + represents the first 8 ports of the range of ports + specified by the object, the second octet represents + the next 8 ports, etc. When a port range is not + specified, a default port range of '1 - 2048' is assumed. + + Within each octet, the most significant bit represents + the lowest numbered port, and the least significant bit + represents the highest numbered port. Thus, each port + of the bridge is represented by a single bit within the + value of this object. If that bit has a value of '1' + then that port is included in the set of ports; the port + is not included if its bit has a value of '0'. + + Note that if the length of this string is less than + 256 octets, any 'missing' octets are assumed to contain + the value zero. An NMS may omit any zero-valued octets + from the end of this string in order to reduce SetPDU size, + and the agent may also omit zero-valued trailing octets, + to reduce the size of GetResponse PDUs." + SYNTAX OCTET STRING (SIZE (0..256)) + +CiscoPortListRange ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Indicates the port range. + + oneto2K(1) indicates that the port number range is + from 1 to 2048. + + twoKto4K(2) indicates that the port number range is + from 2049 to 4096. + + fourKto6K(3) indicates that the port number range is + from 4097 to 6144. + + sixKto8K(4) indicates that the port number range is + from 6145 to 8192. + + eightKto10K(5) indicates that the port number range is + from 8193 to 10240. + + tenKto12K(6) indicates that the port number range is + from 10241 to 12288. + + twelveKto14K(7) indicates that the port number range is + from 12289 to 14336. + + fourteenKto16K(8) indicates that the port number range is + from 14337 to 16384. + + When an object is defined with this textual convention, + it must be accompanied by an object of CiscoPortList + syntax." + SYNTAX INTEGER { + oneto2k(1), + twoKto4K(2), + fourKto6K(3), + sixKto8K(4), + eightKto10K(5), + tenKto12K(6), + twelveKto14K(7), + fourteenKto16K(8) + } + +IfOperStatusReason ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The cause of current operational state of the + interface. + + GLOSSARY: + + BB - Buffer-to-Buffer. + + BB_Credit - Buffer-to-Buffer credit, a link level flow + control mechanism. + + B_Port - A Fibre Channel, Bridging port. + + BPDU - Bridge Protocol Data Unit. + + CDP - Cisco Discovery Protocol. + + Class F - A connectionless service with notification on + non-delivery between E_Ports, used for control, + coordination, and configuration of the Fabric. + + Class N - Refers to any class of service (different types + of frame delivery services) other than Class F. + + E_D_TOV - Error Detect Timeout Value. + + EDP - Error Disabled Policy. + + ENM - Egress Non-Multicast. + + ELP - Exchange Link Parameter. + + E-mode - A fibre channel port providing E_Port + functionality. + + E_Port - A Fabric Expansion Port. + + EPP - Exchange Peer Parameters. + + ESC - Exchange Switch Capabilities. + + Fabric - The set of physically connected fibre channel + switches. + + FEX - Fabric EXtender. + + FC-FS - Fibre Channel Framing and Signaling. + + FCIP - Fibre Channel over IP protocol. + + FCID - Fibre Channel Domain ID. + + FCOE - Fibre Channel Over Ethernet. + + FCOT - Fibre channel optical transmitter. + + FC-PH - The Fibre Channel Physical and Signaling + standard. + + FCSP - Fibre Channel Security Protocol. + + Fibre Channel - The primary protocol for building SANs. + + FICON - An I\O protocol used between IBM (and compatible) + mainframes and storage. + + FLOGI - Fabric Login, used by a node port to establish a + session with the fabric. + + FPC - Fabric Port Channel. + + GBIC - Gigabit Interface Converter; a removable + transceiver module permitting Fibre Channel and + Gigabit Ethernet physical-layer transport. + + Interconnect_Ports - Switch Ports that assume either the + E_Port or B_Port mode are generally referred to + as Interconnect_Ports. + + LACP - Link Access Control Protocol. + + LIP - Loop Initialization Primitive sequence. + + LR - Link Reset, the FC-PH defined primitive sequence + used to initiate a link reset. + + MTU - Maximun transmission unit. + + NOS - Not Operational Sequence, the FC-PH defined + primitive sequence to indicate that the + transmitting port has detected a link failure (or) + offline condition. + + VIC - Virtual Interface Card. + + VPC - Virtual Port Channel. + + NPIV - N Port Identifier Virtualization. + + NPV - NPort Virtualizer. + + Nx_Port - A Fiber Channel Node Port. + + OLS - Offline Sequence, the FC-PH defined primitive + sequence to indicate that the port is entering + into offline state. + + OHMS - Online Health Management System. + + PMON - Port Monitor. + + QoS - Quality of Service. + + R_A_TOV - Resource Allocation Timeout Value. + + RBH - Resource Bundle Hash. + + RCF - Reconfigure Fabric. + + Rxbbcredit - Receive BB credit value configured for + a FC interface. + + SAN - Storage Area Network; a network linking computing + devices to disk or tape arrays and other devices + over Fibre Channel. + + SIF - Service Information Field. + + SDM - Security Device Manager. + + SDP - Secure Device Provisioning. + + SFP - Small Formfactor Pluggable. + + SRP - Spatial Reuse Protocol. + + TE_Port - Trunking E_Port. + + TOV - Time out value. + + UDLD - Uni Directional Link Detection. + + VDC - Virtual Device Context. + + VEM - Virtual Ethernet Module. + + VFC - Virtual Fibre Channel. + + VRF - VPN Routing and Forwarding. + + VSAN - Virtual Storage Area Network. + + WiMAX - Worldwide Interoperability for Microwave Access. + + WPAN - Wireless Personal Area Network. + + WWN - World Wide Name. + + xE_Port - A Fiber channel port that can assume either + E_Port or TE_Port mode. + + The enumerated values which provides the cause of the current + operational state of the interface are, + + 'other(1)' - reasons other than defined here. + + 'none(2)' - no failure. + + 'hwFailure(3)' - hardware failure. + + 'loopbackDiagFailure(4)' - loopback diagnostics failure. + + 'errorDisabled(5)' - the port is not operational due to + some error conditions that require administrative + attention. + + 'swFailure(6)' - software failure. + + 'linkFailure(7)' - physical link failure. + + 'offline(8)' - physical link is in offline state as + defined in the FC-FS standards. + + 'nonParticipating(9)' - during loop initialization, the + port is not allowed to participate in loop operations. + + 'initializing(10)' - port is being initialized. + + 'vsanInactive(11)'- port VSAN is inactive. The port becomes + operational again when the port VSAN is active. + + 'adminDown(12)' - ifAdminStatus is 'down'. + + 'channelAdminDown(13)' - this port is a member of a port + channel and that port channel's ifAdminStatus is + 'down'. + + 'channelOperSuspended(14)' - this port is a member of a + port channel and its operational parameters are + incompatible with the port channel parameters. + + 'channelConfigurationInProgress(15)' - this port is + undergoing a port channel configuration. + + 'rcfInProgress(16)' - an isolated xE_port is transmitting + an reconfigure fabric, requesting a disruptive + reconfiguration in an attempt to build a single, + non-isolated fabric. Only the Interconnect_Ports can + become isolated. + + 'elpFailureIsolation(17)' - during a port initialization + the prospective Interconnect_Ports find incompatible + link parameters. + + 'escFailureIsolation(18) - during a port initialization the + prospective Interconnect_Ports are unable to proceed + with initialization as a result of ESC. + + 'domainOverlapIsolation(19)' - there is a overlap in + domains while attempting to connect two existing + fabrics. + + 'domainAddrAssignFailureIsolation(20)' - the elected + principal switch is not capable of performing domain + address manager functions so no Nx_port traffic can be + forwarded across switches, hence all Interconnect_Ports + in the switch are isolated. + + 'domainOtherSideEportIsolation(21)' - the peer E_port is + isolated. + + 'domainInvalidRcfReceived(22)' - invalid RCF received. + + 'domainManagerDisabled(23) - domain manager is disabled. + + 'zoneMergeFailureIsolation(24)' - the two Interconnect_Ports + cannot merge zoning configuration after having exchanged + merging request for zoning. + + 'vsanMismatchIsolation(25)' - this VSAN is not configured + on both sides of a trunk port. + + 'parentDown(26)' - the physical port to which this interface + is bound is down. + + 'srcPortNotBound(27)'- no source port is specified for this + interface. + + 'interfaceRemoved(28)' - interface is being removed. + + 'fcotNotPresent(29)' - FCOT (GBIC) not present. + + 'fcotVendorNotSupported(30)' - FCOT (GBIC) vendor is not + supported. + + 'incompatibleAdminMode(31)' - port administrative mode is + incompatible with port capabilities. + + 'incompatibleAdminSpeed(32)' - port speed is incompatible + with port capabilities. + + 'suspendedByMode(33)' - port that belongs to a port channel + is suspended due to incompatible operational mode. + + 'suspendedBySpeed(34)' - port that belongs to a port channel + is suspended due to incompatible operational speed. + + 'suspendedByWwn(35)' - port that belongs to a port channel + is suspended due to incompatible remote switch WWN. + + 'domainMaxReTxFailure(36)' - domain manager failure after + maximum retries. + + 'eppFailure(37)' - trunk negotiation protocol failure after + maximum retries. + + 'portVsanMismatchIsolation(38)' - an attempt is made to + connect two switches using non-trunking ports having + different port VSANs. + + 'loopbackIsolation(39)' - port is connected to another port + in the same switch. + + 'upgradeInProgress(40)' - linecard upgrade in progress. + + 'incompatibleAdminRxBbCredit(41)' - receive BB credit is + incompatible. + + 'incompatibleAdminRxBufferSize(42)' - receive buffer size + is incompatible. + + 'portChannelMembersDown(43)' - no operational members. + + 'zoneRemoteNoRespIsolation(44)' - isolation due to remote + zone server not responding. + + 'firstPortUpAsEport(45)' - in a over subscribed line card, + when the first port in a group is up in E-mode, other + ports in that group cannot be brought up. + + 'firstPortNotUp(46)' - in a over subscribed line card, + first port cannot be brought up in E-mode when the + other ports in the group are up. + + 'peerFcipPortClosedConnection(47)' - port went down because + peer FCIP port closed TCP connection. + + 'peerFcipPortResetConnection(48)' - port went down because + the TCP connection was reset by the peer FCIP port. + + 'fcipPortMaxReTx(49)' - FCIP port went down due to maximum + TCP re-transmissions reached the configured limit. + + 'fcipPortKeepAliveTimerExpire(50)' - FCIP port went down + due to TCP keep alive timer expired. + + 'fcipPortPersistTimerExpire(51)' - FCIP port went down due + to TCP persist timer expired. + + 'fcipPortSrcLinkDown(52)' - FCIP port went down due to + Ethernet link down. + + 'fcipPortSrcAdminDown(53)' - FCIP port went down because + the source Ethernet link was administratively shutdown. + + 'fcipPortAdminCfgChange(54)' - FCIP port went down due to + configuration change. + + 'fcipSrcPortRemoved(55)' - FCIP port went down due to source + port removal. + + 'fcipSrcModuleNotOnline(56)' - FCIP port went down due to + source module not online. + + 'invalidConfig(57)' - this port has a misconfiguration with + respect to port channels. + + 'portBindFailure(58)' - port got isolated due to port bind + failure. + + 'portFabricBindFailure(59)' - port got isolated due to + fabric bind failure. + + 'noCommonVsanIsolation(60)' - trunk is isolated because + there are no common VSANs with peer. + + 'ficonVsanDown (61)' - FICON VSAN down. + + 'invalidAttachment (62)' - invalid attachment. + + 'portBlocked (63)' - port blocked due to FICON. + + 'incomAdminRxBbCreditPerBuf (64)' - disabled due to + incompatible administrative port rxbbcredit, + performance buffers. + + 'tooManyInvalidFlogis (65)' - suspended due to too many + invalid FLOGIs. + + 'deniedDueToPortBinding (66)' - suspended due to port + binding. + + 'elpFailureRevMismatch (67)' - isolated for ELP failure due + to revision mismatch. + + 'elpFailureClassFParamErr (68)' - isolated for ELP failure + due to Class F parameter error. + + 'elpFailureClassNParamErr (69)' - isolated for ELP failure + due to Class N parameter error. + + 'elpFailureUnknownFlowCtlCode (70)' - isolated for ELP + failure due to invalid flow control code. + + 'elpFailureInvalidFlowCtlParam (71)' - isolated for ELP + failure due to invalid flow control parameter. + + 'elpFailureInvalidPortName(72)' - isolated for ELP failure + due to invalid port name. + + 'elpFailureInvalidSwitchName (73)' - isolated for ELP + failure due to invalid switch name. + + 'elpFailureRatovEdtovMismatch (74)' - isolated for ELP + failure due to R_A_TOV or E_D_TOV mismatch. + + 'elpFailureLoopbackDetected (75)' - isolated for ELP + failure due to loopback detected. + + 'elpFailureInvalidTxBbCredit (76)' - isolated for ELP + failure due to invalid transmit BB credit. + + 'elpFailureInvalidPayloadSize (77)' - isolated for ELP + failure due to invalid payload size. + + 'bundleMisCfg (78)' - misconfiguration in port channel + membership detected. + + 'bitErrRuntimeThreshExceeded (79)' - bit error rate too + high. It has exceeded the run time threshold. + + 'linkFailLinkReset (80)' - link failure due to link reset. + + 'linkFailPortInitFail (81)' - link failure due to port + initialization failure. + + 'linkFailPortUnusable (82)' - link failure due to port + unusable. + + 'linkFailLossOfSignal (83)' - link failure due to loss of + signal. + + 'linkFailLossOfSync (84)' - link failure due to loss of + sync. + + 'linkFailNosRcvd (85)' - link failure due to non-operational + sequences received. + + 'linkFailOLSRcvd (86)' - link failure due to offline + sequences received. + + 'linkFailDebounceTimeout (87)' - link failure due to + re-negotiation failed. + + 'linkFailLrRcvd (88)' - link failure when link reset(LR) + operation fails due to non-empty receive queue. + + 'linkFailCreditLoss (89)' - link failure due to excessive + credit loss indications. + + 'linkFailRxQOverflow (90)' - link failure due to receive + queue overflow. + + 'linkFailTooManyInterrupts (91)' - link failure due to + excessive port interrupts. + + 'linkFailLipRcvdBb (92)' - link failure when loop + initialization(LIP) operation fails due to non empty + receive queue. + + 'linkFailBbCreditLoss (93)' - link failure when link + reset(LR) operation fails due to queue not empty. + + 'linkFailOpenPrimSignalTimeout (94)' - link failure due to + open primitive signal timeout while receive queue + not empty. + + 'linkFailOpenPrimSignalReturned (95)' - link failure due to + open primitive signal returned while receive queue + not empty. + + 'linkFailLipF8Rcvd (96)' - link failure due to F8 LIP + received. + + 'linkFailLineCardPortShutdown (97)' - link failure due to + port shutdown. + + 'fcspAuthenFailure (98)' - fibre channel security protocol + authorization fail. + + 'fcotChecksumError (99)' - FCOT SPROM checksum error. + + 'ohmsExtLoopbackTest (100)' - link suspended due to external + loopback diagnostics failure. + + 'invalidFabricBindExchange (101)' - invalid fabric binding + exchange. + + 'tovMismatch (102)' - link isolation due to TOV mismatch. + + 'ficonNotEnabled (103)' - FICON not enabled. + + 'ficonNoPortNumber (104)' - no FICON port number. + + 'ficonBeingEnabled (105)' - FICON is being enabled. + + 'ePortProhibited (106)' - port down because FICON prohibit + mask in place for E/TE port. + + 'portGracefulShutdown (107)' - port has been shutdown + gracefully. + + 'trunkNotFullyActive (108)' - some of the VSANs which are + common with the peer are not up. + + 'fabricBindingSwitchWwnNotFound (109)' - peer switch WWN not + found in fabric binding active database. + + 'fabricBindingDomainInvalid (110)' - peer domain ID is + invalid in fabric binding active database. + + 'fabricBindingDbMismatch (111)' - fabric binding active + database mismatch with peer. + + 'fabricBindingNoRspFromPeer (112)' - fabric binding no + response from peer. + + 'dpvmVsanSuspended (113)' - dpvm vsan is suspended. + + 'dpvmVsanNotFound (114)' - dpvm vsan not found. + + 'trackedPortDown (115)' - port down because tracked + port is down. + + 'ecSuspendedOnLoop (116)' - port suspended because extended + BB credits are configured on loop port. + + 'isolateBundleMisCfg (117)' - port isolated due to bundle + mis-configuration. + + 'noPeerBundleSupport (118)' - peer port does not support + bundle. + + 'portBringupIsolation (119)' - trunk port isolated during + bringup time. + + 'domainNotAllowedIsolated (120)' - port isolated due to + domain not allowed. + + 'virtualIvrDomainOverlapIsolation (121)' - port isolated + due to virtual IVR domain overlap. + + 'outOfService (122)' - port is in out of service state. + + 'portAuthFailed (123)' - port has encountered an 802.1x + authentication failure. + + 'bundleStandby (124)' - port cannot be brought up in + a bundle, since the bundle has max members. + + 'portConnectorTypeErr (125)' - Error in the port connector + type (SFP). + + 'errorDisabledReInitLmtReached (126)' - the port is not + operational after trying to initialize the port multiple + times due to some erorrs. + + 'ficonDupPortNum (127)' - the ficon vsan has a duplicate + port number. + + 'localRcf (128)' - fcdomain applied a locally disruptive + reconfiguration (the local domain became invalid; no + RCF frames have been sent outside the local switch). + + 'twoSwitchesWithSameWWN (129)' - merge attempt between + VSANs containing the same WWN. If the user attempts to + merge two different VSANs and both have at least one + switch with the same WWN then the link in between the + VSANs is isolated. + + 'invalidOtherSidePrincEFPReqRecd (130)' - EFP request frame + indicating a principal switch other than the locally + known one. + + 'domainOther (131)' - other domain manager reasons not + defined here. + + 'elpFailureAllZeroPeerWWNRcvd (132)' - isolated for ELP + failure due to peer WWN is received with all zeros. + + 'preferredPathIsolation (133)' - port isolated due to + preferred path not able to program the routes. + + 'fcRedirectIsolation (134)' - port isolated due to + FC Redirect not being able to program routes. + + 'portActLicenseNotAvailable (135)' - port not brought up + due to lack of port activation licenses. + + 'sdmIsolation (136)' - port isolated due to SDM + (Security Device Manager) not being + able to program routes. + + 'fcidAllocationFailed (137)' - port down due to failure + in FCID (Fibre Channel Domain ID) allocation. + + 'externallyDisabled (138)' - port externally disabled. + + 'unavailableNPVUpstreamPort (139)' - NPV + (NPort Virtualizer) upstream port not available. + + 'unavailableNPVPrefUpstreamPort (140)' - NPV + (NPort Virtualizer) preferred + upstream port not available. + + 'sfpReadError (141)' - the port is not operational due to + SFP (Small Formfactor Pluggable) read error. + + 'stickyDownOnLinkFailure (142)' - the port is + not operational due to link failure + in the sticky down mode. + + 'tooManyLinkFlapsErr (143)' - too many link flaps + on the port in a short interval. + + 'unidirectionalUDLD (144)' - unidirectional UDLD + (Uni Directional Link Detection) detected. + + 'txRxLoopUDLD (145)' - UDLD (Uni Directional + Link Detection) Tx Rx loop. + + 'neighborMismatchUDLD (146)' - UDLD + (Uni Directional Link Detection) neighbor mismatch. + + 'authzPending (147)' - authorization pending. + + 'hotStdbyInBundle (148)' - hot standby in bundle. + + 'incompleteConfig (149)' - all parameters on the port + have not been configured. + + 'incompleteTunnelCfg (150)' - incomplete tunnel config. + + 'hwProgrammingFailed (151)' - hardware programming failed. + + 'tunnelDstUnreachable (152)' - no route to + tunnel destination address. + + 'suspendByMtu (153)' - MTU allocation failed. + + 'sfpInvalid (154)' - SFP (Small Formfactor Pluggable) + is not Cisco certified. + + 'sfpAbsent (155)' - SFP (Small Formfactor + Pluggable) is absent. + + 'portCapabilitiesUnknown (156)' - the capabilities of the + port are unknown. + + 'channelErrDisabled (157)' - the port-channel to which + the port belongs is in error disabled state. + + 'vrfMismatch (158)' - Mismatch in source and transport VRF + (VPN Routing and Forwarding). + + 'vrfForwardReferencing (159)' - Forward referencing + transport VRF (VPN Routing and Forwarding). + + 'dupTunnelConfigDetected (160)' - two tunnel interfaces + with same configuration is not allowed. + + 'primaryVLANDown (161)' - primary VLAN is in down state. + + 'vrfUnusable (162)' - VRF (VPN Routing and Forwarding) + is unusable. + + 'errDisableHandShkFailure (163)' - port is not operational + due to an internal handshake failure. + + 'errDisabledBPDUGuard (164)' - BPDUGuard + (Bridge Protocol Data Unit) triggered + error disable on the port. + + 'dot1xSecViolationErrDisabled (165)' - error disabled + due to dot1x security violation. + + 'emptyEchoUDLD (166)' - UDLD (Uni Directional + Link Detection) empty echo. + + 'vfTaggingCapErr (167)' - VF Tagging capability + mismatch error. + + 'portDisabled (168)' - Port disabled. + + 'tunnelModeNotConfigured (169)' - Tunnel Mode is not + configured. + + 'tunnelSrcNotConfigured (170)' - Tunnel Source is not + configured. + + 'tunnelDstNotConfigured (171)' - Tunnel Destination + is not configured. + + 'tunnelUnableToResolveSrcIP (172)' - Unable to resolve + tunnel source IP address. + + 'tunnelUnableToResolveDstIP (173)' - Unable to resolve + tunnel destination IP address. + + 'tunnelVrfDown (174)' - Tunnel VRF down. + + 'sifAdminDown (175)' - SIF (Service Information Field) + is admin down. + + 'phyIntfDown (176)' - Physical interface is down. + + 'ifSifLimitExceeded (177)' - Interface SIF + (Service Information Field)limit is exceeded. + + 'sifHoldDown (178)' - SIF (Service Information Field) + hold down. + + 'noFcoe (179)' - No FCOE (Fibre Channel Over Ethernet) + configuration. + + 'dcxCompatMismatch (180)' - DCX Compatibility Mismatch. + + 'isolateBundleLimitExceeded (181)' - Isolation due to + bundle limit exceeded. + + 'sifNotBound (182)' - SIF (ervice Information Field) + is not bound. + + 'errDisabledLacpMiscfg (183)' - Error Disabled due to + LACP (Link Access Control Protocol) misconfig. + + 'satFabricIfDown (184)' - Satellite fabric interface down. + + 'invalidSatFabricIf (185)' - Invalid satellite fabric + interface. + + 'noRemoteChassis (186)' - No remote chassis. + + 'vicEnableNotReceived (187)' - VIC enable not received. + + 'vicDisableReceived (188)' - VIC disable received. + + 'vlanVsanMappingNotEnabled (189)' - VLAN VSAN mapping not + enabled. + + 'stpNotFwdingInFcoeMappedVlan (190)' - STP not forwarding + in FCOE Mapped Vlan. + + 'moduleOffline (191)' - Module Offline. + + 'udldAggModeLinkFailure (192)' - UDLD (Uni Directional Link + Detection) aggresive mode link failure. + + 'stpInconsVpcPeerDisabled (193)' - STP inconsistent + VPC (Virtual Port Channel) peer disabled. + + 'setPortStateFailed (194)' - Set port state failed. + + 'suspendedByVpc (195)' - Suspended by VPC + (Virtual Port Channel). + + 'vpcCfgInProgress (196)' - VPC (Virtual Port Channel) + configuration in progress. + + 'vpcPeerLinkDown (197)' - VPC (Virtual Port Channel) + peer link down. + + 'vpcNoRspFromPeer (198)' - VPC (Virtual Port Channel) + no response from peer. + + 'protoPortSuspend (199)' - Proto port suspend. + + 'tunnelSrcDown (200)' - Tunnel source down. + + 'cdpInfoUnavailable (201)' - CDP + (Cisco Discovery Protocol) information unavailable. + + 'fexSfpInvalid (202)' - FEX (Fabric Extender) + SFP (Small Formfactor Pluggable) invalid. + + 'errDisabledIpConflict (203)' - Error Disabled due to IP + conflict. + + 'fcotClkRateMismatch (204)' - FCOT CLK rate mismatch. + + 'portGuardTrustSecViolation (205)' - Error disabled due + to port guard (Cisco Trusted Security Violation). + + 'sdpTimeout (206)' - SDP (Secure Device Provisioning) + timeout. + + 'satIncompatTopo (207)' - Satellite incompatible topology. + + 'waitForFlogi (208)' - Wait for FLOGI. + + 'satNotConfigured (209)' - Satellite not configured. + + 'npivNotEnabledInUpstream (210)' - NPIV (N Port Identifier + Virtualization) not enabled in upstream. + + 'vsanMismatchWithUpstreamSwPort (211)' - VSAN + mismatch with upstream switch port. + + 'portGuardBitErrRate (212)' - Error disabled due to port + guard (Bit Error Rate). + + 'portGuardSigLoss (213)' - Error disabled due to + port guard (Signal Loss). + + 'portGuardSyncLoss (214)' - Error disabled due to port + guard (Sync Loss). + + 'portGuardLinkReset (215)' - Error disabled due to port + guard (Link Reset). + + 'portGuardCreditLoss (216)' - Error disabled due to port + guard (Credit Loss). + + 'ipQosMgrPolicyAppFailure (217)' - IP QOS Manager policy + application failure. + + 'pauseRateLimitErrDisabled (218)' - Port error disabled due + to pause rate limit condition. + + 'lstGrpUplinkDown (219)' - EthPM LSTGRP downstream link + down due to upstream link down. + + 'stickyDnLinkFailure (220)' - Port kept in error disabled + state due to Link Failure. + + 'routerMacFailure (221)' - Router MAC failure. + + 'dcxMultipleMsapIds (222)' - Port error disabled due to + multiple MSAP IDs (DCX). + + 'dcxHundredPdusRcvdNoAck (223)' - Hundred PDUs received + without ACK (DCX). + + 'enmSatIncompatibleUplink (224)' - Satellite Incompatible + Uplink. + + 'enmLoopDetected (225)' - Loop Detected (ENM). + + 'nonStickyExternallyDisabled (226)' - Disabled by VPD + Manager with shut/no shut allowed. + + 'nonStickyExternallyDisabled (227)' - Sub-group ID + not assigned. + + 'vemUnlicensed (228)' - VEM Unlicensed. + + 'profileNotFound (229)' - Profile not found. + + 'nonExistentVlan (230)' - VLAN does not exist. + + 'vlanInvalidType (231)' - Invalid VLAN type. + + 'vlanDown (232)' - VLAN down. + + 'vpcPeerUpgrade (233)' - VPC Peer Upgrade. + + 'ipQosDcbxpCompatFailure (234)' - IPQOS DCBXP compatibility + failure. + + 'nonCiscoHbaVfTag (235)' - Error Disabled due to Non-Cisco + HBA VF Tag. + + 'domainIdConfigMismatch (236)' - Domain ID config mismatch. + + 'sfpSpeedMismatch (237)' - SFP (Small Formfactor Pluggable) + speed mismatch. + 'xcvrInitializing (238)' - Transceiver initializing. + + 'xcvrAbsent (239)' - Transceiver absent. + + 'xcvrInvalid (240)' - Transceiver invalid. + + 'vfcBindingInvalid (241)' - Invalid VFC Binding. + + 'vlanNotFcoeEnabled (242)' - VLAN down due to FCOE + disabled. + + 'pvlanNativeVlanErr (243)' - Private VLAN + Native VLAN error. + + 'ethL2VlanDown (244)' - Ethernet L2 VLAN down. + + 'ethIntfInvalidBinding (245)' - Invalid Binding + to Ethernet Interface. + + 'pmonFailure (246)' - PMON Failure. + + 'l3NotReady (247)' - L3 not ready. + + 'speedMismatch (248)' - Speed Mismatch. + + 'flowControlMismatch (249)' - Flow Control Mismatch. + + 'vdcMode (250)' - VDC mode + + 'suspendedDueToMinLinks (251)' - Suspended due + to Min Links. + + 'enmPinFailLinkDown (252)' - ENM Pin Fail Link Down. + + 'inactiveM1PortFpathActiveVlan (253)' - Inactive M1 Port + F Path Active VLAN. + + 'parentPortDown (254)' - Parent Port Down. + + 'moduleRemoved (255)' - Module Removed. + + 'corePortMct (256)' - Core Port MCT. + + 'nonCorePortMct (257)' - Non Core port MCT. + + 'ficonInorderNotActive (258)'- FICON Inorder Not Active. + + 'invalidEncapsulation (259)' - Invalid Encapsulation. + + 'modemLineDeasserted (260)' - Modem line Deasserted. + + 'ipSecHndshkInProgress (261)' - IP Sec Handshake in + progress. + + 'sfpEthCompliantErr (262)' - Sfp Ethernet compliant error. + + 'cellularModemUnattached (263)' - Cellular Modem + unattached. + + 'outOfGlblRxBuffers (264)' - Out of Global Rx Buffers. + + 'sfpFcCompliantErr (265)' - Sfp Fc compliant Error. + + 'ethIntfNotLicensed (266)' - Ethernet Interface Not + Licensed. + + 'domainIdsInvalid (267)' - Domain IDs Invalid. + + 'fabricNameInvalid (268)' - Fabric Name Invalid. + + 'ficonNoPortSwapLogicalPort (269)' - Ficon No Port Swap Logical Port. + + 'ficonInvalidPortNum (270)' - Ficon Invalid Port Number. + + 'remotePortInL2vpnDown (271)' - Remote Port in L2VPN Down. + + 'suspendedDueToNoLacpPdus (272)' - Suspended due to no LACP PDUs. + + 'fcotValidationFailedAtDriver (273)' - Fcot validation failed at driver. + + 'unsupportedTransceiverMd5DigestNotSame (274)' - Unsupported transceiver MD5 digest not Same. + + 'unsupportedTransceiver (275)' - Unsupport transceiver. + + 'adminStateConfigChange (276)' - Admin state config change. + + 'vlanAllowedList (277)' - Allowed Vlan list configured on the port. + + 'vlanAllowedListOverride (278)' - Allowed Vlan list changed on the port. + + 'vlanAllowedListAdd (279)' - Vlan has been added to the allowed Vlan list on the port. + + 'vlanAllowedListRemove (280)' - Vlan has been removed from the allowed Vlan list on the port. + + 'vlanCfgStateChange (281)' - Port affected due to Vlan state change. + + 'vlanCfgDelete (282)' - Port affected due to Vlan delete. + + 'pppPeerNotResponding (283)' - ppp peer not responding. + + 'pppAuthFailed (284)' - ppp authentication failed. + + 'xcvrAuthFailed (285)' - Transceiver authentication failed. + + 'badFramesRcvdFromLink (286)' - Excessive bad frames received from link. + + 'physicalPortHotStandBy (287)' + - Physical Port in Hot-StandBy State. + + 'wimaxModemUnattached (288)' + - Modem Disconnected from WiMAX network. + + 'wpanModemUnattached (289)' + - Modem Disconnected from WPAN network. + + 'rbhModulo (290)' + - Down due to RBH modulo load-balance feature toggle. + + 'fpcMinLinkNotMet (291)' + - Suspended as the FPC min-link requirement has not + been met. + + 'misCabling (292)' + - Miscabling detected. + + 'rcvSrpOnNonFcoeFex (293)' + - Down due to received SRP for a non-FCOE capable FEX + + 'acessPortOnBd (294)' + - Inactive due to access port is configured with a + Bridge-Domain ID. + + 'lacpMisConfig (295)' + - LACP port suspended due to misconfiguration. + + 'fortyGMemberPort (300)' + - Port is a member of a 40G interface. + + 'goldLoopBackTest (301)' + - Suspended due to Loopback diagnostics. + + 'edpError (302)' + - Down due to EDP enforcement. + + 'vpcCompCheckFailed (303)' + - VPC down because compatibility check failed. + + 'aclQosNoResource (304)' + - Not enough free entries in TCAM bank for QoS. + + 'vpcShutdown (305)' + - VPC shutdown. + + 'notPcMember (306)' + - Port is not a member of a port channel. + + 'systemIntfShut (307)' + - System interface shutdown. + + 'speedGroupConfigMisMatch (308)' + - Speed-Group config does not match type of transceiver. + + 'dot1qMisConfig (310)' + - Dot1q-tunnel misconfiguration. + + 'mdMisMatch (311)' + - Mobility Domain Config Mismatch. + + 'vpcPeerLinkShut (312)' + - Suspended because VPC peer link had been shut down. + + 'notAvailable (313)' + - Port Operation Status is currently not available. + " + SYNTAX INTEGER { + other(1), + none(2), + hwFailure(3), + loopbackDiagFailure(4), + errorDisabled(5), + swFailure(6), + linkFailure(7), + offline(8), + nonParticipating(9), + initializing(10), + vsanInactive(11), + adminDown(12), + channelAdminDown(13), + channelOperSuspended(14), + channelConfigurationInProgress(15), + rcfInProgress(16), + elpFailureIsolation(17), + escFailureIsolation(18), + domainOverlapIsolation(19), + domainAddrAssignFailureIsolation(20), + domainOtherSideEportIsolation(21), + domainInvalidRcfReceived(22), + domainManagerDisabled(23), + zoneMergeFailureIsolation(24), + vsanMismatchIsolation(25), + parentDown(26), + srcPortNotBound(27), + interfaceRemoved(28), + fcotNotPresent(29), + fcotVendorNotSupported(30), + incompatibleAdminMode(31), + incompatibleAdminSpeed(32), + suspendedByMode(33), + suspendedBySpeed(34), + suspendedByWWN(35), + domainMaxReTxFailure(36), + eppFailure(37), + portVsanMismatchIsolation(38), + loopbackIsolation(39), + upgradeInProgress(40), + incompatibleAdminRxBbCredit(41), + incompatibleAdminRxBufferSize(42), + portChannelMembersDown(43), + zoneRemoteNoRespIsolation(44), + firstPortUpAsEport(45), + firstPortNotUp(46), + peerFCIPPortClosedConnection(47), + peerFCIPPortResetConnection(48), + fcipPortMaxReTx(49), + fcipPortKeepAliveTimerExpire(50), + fcipPortPersistTimerExpire(51), + fcipPortSrcLinkDown(52), + fcipPortSrcAdminDown(53), + fcipPortAdminCfgChange(54), + fcipSrcPortRemoved(55), + fcipSrcModuleNotOnline(56), + invalidConfig(57), + portBindFailure(58), + portFabricBindFailure(59), + noCommonVsanIsolation(60), + ficonVsanDown(61), + invalidAttachment(62), + portBlocked(63), + incomAdminRxBbCreditPerBuf(64), + tooManyInvalidFlogis(65), + deniedDueToPortBinding(66), + elpFailureRevMismatch(67), + elpFailureClassFParamErr(68), + elpFailureClassNParamErr(69), + elpFailureUnknownFlowCtlCode(70), + elpFailureInvalidFlowCtlParam(71), + elpFailureInvalidPortName(72), + elpFailureInvalidSwitchName(73), + elpFailureRatovEdtovMismatch(74), + elpFailureLoopbackDetected(75), + elpFailureInvalidTxBbCredit(76), + elpFailureInvalidPayloadSize(77), + bundleMisCfg(78), + bitErrRuntimeThreshExceeded(79), + linkFailLinkReset(80), + linkFailPortInitFail(81), + linkFailPortUnusable(82), + linkFailLossOfSignal(83), + linkFailLossOfSync(84), + linkFailNosRcvd(85), + linkFailOLSRcvd(86), + linkFailDebounceTimeout(87), + linkFailLrRcvd(88), + linkFailCreditLoss(89), + linkFailRxQOverflow(90), + linkFailTooManyInterrupts(91), + linkFailLipRcvdBb(92), + linkFailBbCreditLoss(93), + linkFailOpenPrimSignalTimeout(94), + linkFailOpenPrimSignalReturned(95), + linkFailLipF8Rcvd(96), + linkFailLineCardPortShutdown(97), + fcspAuthenfailure(98), + fcotChecksumError(99), + ohmsExtLoopbackTest(100), + invalidFabricBindExchange(101), + tovMismatch(102), + ficonNotEnabled(103), + ficonNoPortNumber(104), + ficonBeingEnabled(105), + ePortProhibited(106), + portGracefulShutdown(107), + trunkNotFullyActive(108), + fabricBindingSwitchWwnNotFound(109), + fabricBindingDomainInvalid(110), + fabricBindingDbMismatch(111), + fabricBindingNoRspFromPeer(112), + dpvmVsanSuspended(113), + dpvmVsanNotFound(114), + trackedPortDown(115), + ecSuspendedOnLoop(116), + isolateBundleMisCfg(117), + noPeerBundleSupport(118), + portBringupIsolation(119), + domainNotAllowedIsolated(120), + virtualIvrDomainOverlapIsolation(121), + outOfService(122), + portAuthFailed(123), + bundleStandby(124), + portConnectorTypeErr(125), + errorDisabledReInitLmtReached(126), + ficonDupPortNum(127), + localRcf(128), + twoSwitchesWithSameWWN(129), + invalidOtherSidePrincEFPReqRecd(130), + domainOther(131), + elpFailureAllZeroPeerWWNRcvd(132), + preferredPathIsolation(133), + fcRedirectIsolation(134), + portActLicenseNotAvailable(135), + sdmIsolation(136), + fcidAllocationFailed(137), + externallyDisabled(138), + unavailableNPVUpstreamPort(139), + unavailableNPVPrefUpstreamPort(140), + sfpReadError(141), + stickyDownOnLinkFailure(142), + tooManyLinkFlapsErr(143), + unidirectionalUDLD(144), + txRxLoopUDLD(145), + neighborMismatchUDLD(146), + authzPending(147), + hotStdbyInBundle(148), + incompleteConfig(149), + incompleteTunnelCfg(150), + hwProgrammingFailed(151), + tunnelDstUnreachable(152), + suspendByMtu(153), + sfpInvalid(154), + sfpAbsent(155), + portCapabilitiesUnknown(156), + channelErrDisabled(157), + vrfMismatch(158), + vrfForwardReferencing(159), + dupTunnelConfigDetected(160), + primaryVLANDown(161), + vrfUnusable(162), + errDisableHandShkFailure(163), + errDisabledBPDUGuard(164), + dot1xSecViolationErrDisabled(165), + emptyEchoUDLD(166), + vfTaggingCapErr(167), + portDisabled(168), + tunnelModeNotConfigured(169), + tunnelSrcNotConfigured(170), + tunnelDstNotConfigured(171), + tunnelUnableToResolveSrcIP(172), + tunnelUnableToResolveDstIP(173), + tunnelVrfDown(174), + sifAdminDown(175), + phyIntfDown(176), + ifSifLimitExceeded(177), + sifHoldDown(178), + noFcoe(179), + dcxCompatMismatch(180), + isolateBundleLimitExceeded(181), + sifNotBound(182), + errDisabledLacpMiscfg(183), + satFabricIfDown(184), + invalidSatFabricIf(185), + noRemoteChassis(186), + vicEnableNotReceived(187), + vicDisableReceived(188), + vlanVsanMappingNotEnabled(189), + stpNotFwdingInFcoeMappedVlan(190), + moduleOffline(191), + udldAggModeLinkFailure(192), + stpInconsVpcPeerDisabled(193), + setPortStateFailed(194), + suspendedByVpc(195), + vpcCfgInProgress(196), + vpcPeerLinkDown(197), + vpcNoRspFromPeer(198), + protoPortSuspend(199), + tunnelSrcDown(200), + cdpInfoUnavailable(201), + fexSfpInvalid(202), + errDisabledIpConflict(203), + fcotClkRateMismatch(204), + portGuardTrustSecViolation(205), + sdpTimeout(206), + satIncompatTopo(207), + waitForFlogi(208), + satNotConfigured(209), + npivNotEnabledInUpstream(210), + vsanMismatchWithUpstreamSwPort(211), + portGuardBitErrRate(212), + portGuardSigLoss(213), + portGuardSyncLoss(214), + portGuardLinkReset(215), + portGuardCreditLoss(216), + ipQosMgrPolicyAppFailure(217), + pauseRateLimitErrDisabled(218), + lstGrpUplinkDown(219), + stickyDnLinkFailure(220), + routerMacFailure(221), + dcxMultipleMsapIds(222), + dcxHundredPdusRcvdNoAck(223), + enmSatIncompatibleUplink(224), + enmLoopDetected(225), + nonStickyExternallyDisabled(226), + subGroupIdNotAssigned(227), + vemUnlicensed(228), + profileNotFound(229), + nonExistentVlan(230), + vlanInvalidType(231), + vlanDown(232), + vpcPeerUpgrade(233), + ipQosDcbxpCompatFailure(234), + nonCiscoHbaVfTag(235), + domainIdConfigMismatch(236), + sfpSpeedMismatch(237), + xcvrInitializing(238), + xcvrAbsent(239), + xcvrInvalid(240), + vfcBindingInvalid(241), + vlanNotFcoeEnabled(242), + pvlanNativeVlanErr(243), + ethL2VlanDown(244), + ethIntfInvalidBinding(245), + pmonFailure(246), + l3NotReady(247), + speedMismatch(248), + flowControlMismatch(249), + vdcMode(250), + suspendedDueToMinLinks(251), + enmPinFailLinkDown(252), + inactiveM1PortFpathActiveVlan(253), + parentPortDown(254), + moduleRemoved(255), + corePortMct(256), + nonCorePortMct(257), + ficonInorderNotActive(258), + invalidEncapsulation(259), + modemLineDeasserted(260), + ipSecHndshkInProgress(261), + sfpEthCompliantErr(262), + cellularModemUnattached(263), + outOfGlblRxBuffers(264), + sfpFcCompliantErr(265), + ethIntfNotLicensed(266), + domainIdsInvalid(267), + fabricNameInvalid(268), + ficonNoPortSwapLogicalPort(269), + ficonInvalidPortNum(270), + remotePortInL2vpnDown(271), + suspendedDueToNoLacpPdus(272), + fcotValidationFailedAtDriver(273), + unsupportedTransceiverMd5DigestNotSame(274), + unsupportedTransceiver(275), + adminStateConfigChange(276), + vlanAllowedList(277), + vlanAllowedListOverride(278), + vlanAllowedListAdd(279), + vlanAllowedRemove(280), + vlanCfgStateChange(281), + vlanCfgDelete(282), + pppPeerNotResponding(283), + pppAuthFailed(284), + xcvrAuthFailed(285), + badFramesRcvdFromLink(286), + physicalPortHotStandBy(287), + wimaxModemUnattached(288), + wpanModemUnattached(289), + rbhModulo(290), + fpcMinLinkNotMet(291), + misCabling(292), + rcvSrpOnNonFcoeFex(293), + acessPortOnBd(294), + lacpMisConfig(295), + fortyGMemberPort(300), + goldLoopBackTest(301), + edpError(302), + vpcCompCheckFailed(303), + aclQosNoResource(304), + vpcShutdown(305), + notPcMember(306), + systemIntfShut(307), + speedGroupConfigMisMatch(308), + dot1qMisConfig(310), + mdMisMatch(311), + vpcPeerLinkShut(312), + notAvailable(313) + } + +EntLogicalIndexOrZero ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This textual convention is an extension of entLogicalIndex. + If non-zero, the semantic is same as entLogicalIndex object. + If zero, no appropriate entLogicalIndex exists. Any additional + semantics must be defined as part of the description of any + object which uses this syntax." + SYNTAX Integer32 (0..2147483647) + +CiscoURLString ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This textual convention defines the URL string. + The Universal Resource Locator(URL). The URL strings + are compact string representation for a resource + available via internet. This is the address location + of the page to load. The string should represent a + fully qualifying string with the format + 'protocol:/server/page'. In general the string should + point to any value that can be saved/loaded. + Any limitation for the URL must be defined as part of + the description of any object which uses this syntax." + + REFERENCE "Uniform Resource Locators. RFC 1738." + SYNTAX OCTET STRING (SIZE (1..255)) + +CiscoURLStringOrEmpty ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This textual convention is an extension of CiscoURLString. + This extension permits the additional value of empty (zero + length) string. The description of any object which uses this + syntax must specifically describe the meaning of empty string + value." + + REFERENCE "Uniform Resource Locators. RFC 1738." + SYNTAX OCTET STRING (SIZE (0..255)) + +CiscoHTTPResponseStatusCode ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This corresponds to the HTTP Status code. + The Status-Code element in HTTP response is + a 3-digit integer result code of the attempt + to understand and satisfy the HTTP request + The Status-Code is intended for use by automata. + + The first digit of the Status-Code defines the class of + response. The last two digits do not have any + categorization role. There are 5 values for the first digit: + + - 1xx: Informational - Request received, continuing process + + - 2xx: Success - The action was successfully received, + understood, and accepted + + - 3xx: Redirection - Further action must be taken in order + to complete the request + + - 4xx: Client Error - The request contains bad syntax + or cannot be fulfilled + + - 5xx: Server Error - The server failed to fulfill an + apparently valid request." + + REFERENCE + "RFC 2616 Section 6.1.1 Status Code and Reason Phrase." + SYNTAX Unsigned32 (100..599) + +CvE164Address ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "A UTF-8 string limited to the character set defined for + E.164, '0123456789*#,'. + Note that represents the double quote which + cannot be contained in a SMI description clause. + OR + An IA5String limited to the character set '0123456789*#,.'" + + REFERENCE + "ITU-T E.164, Q.931 chapter 4.5.10 + ITU-H H.225.0 Annex H" + SYNTAX OCTET STRING (SIZE (1..128)) + +CiscoVlanList ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Each octet within this value specifies a set of eight + VLANs. The object defined by this textual convention + can specify a VLAN range of 1k VLANs in its description. + Example: 0 - 1023, 1024 - 2047, etc. The first octet + represents the first 8 VLANs of the range of VLANs + specified by the object, the second octet represents + the next 8 VLANs, etc. When a VLAN range is not + specified, a default VLAN range of '0 - 1023' is assumed. + + Within each octet, the most significant bit represents + the lowest numbered VLAN, and the least significant bit + represents the highest numbered VLAN. Thus, each VLAN + of the device is represented by a single bit within the + value of this object. If that bit has a value of '1' + then that VLAN is included in the set of VLANs; the VLAN + is not included if its bit has a value of '0'. + + Note that if the length of this string is less than + 128 octets, any 'missing' octets are assumed to contain + the value zero. An NMS may omit any zero-valued octets + from the end of this string in order to reduce SetPDU size, + and the agent may also omit zero-valued trailing octets, + to reduce the size of GetResponse PDUs." + SYNTAX OCTET STRING (SIZE (0..128)) + +CiscoCosList ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Each bit represents a CoS value (0 through 7)." + SYNTAX BITS { + cos0(0), + cos1(1), + cos2(2), + cos3(3), + cos4(4), + cos5(5), + cos6(6), + cos7(7) + } + +CiscoPbbServiceIdentifier ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An integer-value which identifies the service instance of + the Provider Backbone Bridge frame." + + REFERENCE "IEEE P802.1ah/D3.3 chapter 9.8, December 2006" + SYNTAX Unsigned32 (1..16777216) + +CiscoBridgeDomain ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An object with this syntax contains a bridge domain number + which is used to distinguish between multiple bridge domains. A + bridge domain represents a set of (logical) Ethernet segments + which are interconnected by 802.1D bridges. 802.1Q allows for a + maximum of 4095 VLANs within a bridge domain. Some devices can + be connected to multiple bridge domains, e.g., routers with + some of their interfaces in one bridge domain and other + interfaces in other bridge domain. In such devices, the + combination of bridge-domain-number and VLAN-id can be used to + uniquely identify any VLAN across all interfaces." + SYNTAX Unsigned32 (1..65535) + +Cisco2KVlanList ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Each octet within this value specifies a set of eight VLANs. + The object defined by this textual convention can specify a VLAN + range of 2k VLANs in its description. Example: 0 - 2047, 2048 - + 4095, etc. The first octet represents the first 8 VLANs of the + range of VLANs specified by the object, the second octet + represents the next 8 VLANs, etc. + + Within each octet, the most significant bit represents the + lowest numbered VLAN, and the least significant bit represents + the highest numbered VLAN. Thus, each VLAN of the device is + represented by a single bit within the value of this object. If + that bit has a value of '1' then that VLAN is included in the + set of VLANs; the VLAN is not included if its bit has a value of + '0'. + + Note that if the length of this string is less than 256 octets, + any 'missing' octets are assumed to contain the value zero. An + NMS may omit any zero-valued octets from the end of this string + in order to reduce SetPDU size, and the agent may also omit + zero-valued trailing octets, to reduce the size of GetResponse + PDUs." + SYNTAX OCTET STRING (SIZE (0..256)) + +CiscoInterfaceIndexList ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This textual convention contains a list of ifIndex values. + + Each ifIndex value is represented by four octets. + Every set of four octets represents a value of an instance + of ifIndex object, defined in IF-MIB, corresponding to a + particular interface. + + For example, the first octet to the fourth octet represent a + value of the instance of ifIndex object for the first + interface in the list. The fifth octet to the eighth octet + represent a value of the instance of ifIndex object for + the second interface in the list. + + Up to 64 interfaces can be represented by this textual + convention." + SYNTAX OCTET STRING (SIZE (0..256)) + +CiscoVrfName ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The name of the Virtual Private Network Routing and + Forwarding (VRF) domain. + + Semantics of a zero length CiscoVrfName are object-specific + and must be defined as part of the description of any object + which uses this syntax." + SYNTAX OCTET STRING (SIZE (0..32)) + +CiscoEntityIndexList ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This text convention contains a list of entPhysicalIndex + values. + + Each entPhysicalIndex value is represented by four + octets. Every set of four octets represents a value of an + instance of entPhysicalIndex object, defined in ENTITY-MIB, + corresponding to a particular physical entity. + + For example, the first octet to the fourth octet + represents a value of the instance of entPhysicalIndex object + for the first physical entity in the list. The fifth octet to + the eighth octet represents a value of the instance of + entPhysicalIndex object for the second physical entity in the + list. + + Up to 64 physical entities can be represented by this + textual convention." + SYNTAX OCTET STRING (SIZE (0..256)) + +CiscoVlanIndex ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The VLAN-id of a VLAN on ISL or 802.1q trunks. + + + For a new object which needs the vlan-id of a VLAN as + its SYNTAX, it is suggested to import VlanIndex or VlanId + from Q-BRIDGE-MIB instead of importing this TC. + + + For a existing MIB which have the import of VlanIndex + from CISCO-VTP-MIB, it is suggested to import this TC." + SYNTAX Integer32 (0..4095) + +CiscoAbsZeroBasedCounter64 ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This TC describes an object which counts events with + the following semantics: objects of this type will be + set to zero(0) on creation and will thereafter count + appropriate events, it locks at the maximum value of + 2^64-1 (18446744073709551615 decimal) if the counter + overflows. This TC may be used only in situations where + wrapping is not possible or extremely unlikely situation." + SYNTAX Counter64 + +END + diff --git a/MIBs/CISCO-VTP-MIB.my b/MIBs/CISCO-VTP-MIB.my new file mode 100644 index 0000000..7f6f266 --- /dev/null +++ b/MIBs/CISCO-VTP-MIB.my @@ -0,0 +1,6521 @@ +-- ***************************************************************** +-- Cisco VTP MIB +-- +-- February, 1997 Chris Young +-- April, 2003 Wen Xu +-- July, 2003 Wen Xu +-- August, 2003 Wen Xu +-- November, 2003 Wen Xu +-- February, 2004 Wen Xu +-- +-- Copyright (c) 1996-2013 by Cisco Systems Inc. +-- All rights reserved. +-- ***************************************************************** +-- + +CISCO-VTP-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, + OBJECT-TYPE, + NOTIFICATION-TYPE, + Counter32, + IpAddress, + Gauge32, + Integer32, + Unsigned32 + FROM SNMPv2-SMI + MODULE-COMPLIANCE, + OBJECT-GROUP, + NOTIFICATION-GROUP + FROM SNMPv2-CONF + TEXTUAL-CONVENTION, + RowStatus, + DisplayString, + DateAndTime, + TruthValue, + TestAndIncr, + TimeStamp + FROM SNMPv2-TC + InterfaceIndex, + ifIndex, + InterfaceIndexOrZero + FROM IF-MIB + InetAddress, + InetAddressType + FROM INET-ADDRESS-MIB + OwnerString + FROM RMON-MIB + SnmpAdminString + FROM SNMP-FRAMEWORK-MIB + Cisco2KVlanList + FROM CISCO-TC + ciscoMgmt + FROM CISCO-SMI; + + +ciscoVtpMIB MODULE-IDENTITY + LAST-UPDATED "201310140000Z" + ORGANIZATION "Cisco Systems, Inc." + CONTACT-INFO + "Cisco Systems + Customer Service + + Postal: 170 W Tasman Drive + San Jose, CA 95134 + USA + + Tel: +1 800 553-NETS + + E-mail: cs-wbu@cisco.com, + cs-lan-switch-snmp@cisco.com" + DESCRIPTION + "The MIB module for entities implementing the VTP + protocol and Vlan management." + REVISION "201310140000Z" + DESCRIPTION + "Added following OBJECT-GROUP + - vtpSourceInterfaceGroup + - vtpConfigFileGroup + - vtpVlanLocalShutdownGroup + - vtpLocalUpdaterGroup + - vtpDeviceIdGroup + Added new compliance + - vtpMIBCompliance16." + REVISION "201005120000Z" + DESCRIPTION + "Added vlanTrunkPortActiveVlansGroup. + Updated the description of vtpServerDisabled." + REVISION "200912030000Z" + DESCRIPTION + "Added vtpTrunkPruningGroup3 and + vtpConfigNotificationsGroup8. Modified the + description of vtpNotificationsEnabled and + managementDomainPruningState." + REVISION "200803070000Z" + DESCRIPTION + "Added vlanStatsGroup. Deprecated + vtpConfigNotificationsGroup5 and replaced + it with vtpConfigNotificationsGroup6 and + vtpConfigNotificationsGroup7." + REVISION "200710040000Z" + DESCRIPTION + "Correct the descriptions of the object + vtpConfigDigestErrors and the tables vtpVlanTable + and vtpInternalVlanTable." + REVISION "200602170000Z" + DESCRIPTION + "Removed the OwnerString TEXTUAL-CONVENTION and + imported the same from RMON-MIB." + REVISION "200402110000Z" + DESCRIPTION + "Added 'dynamicGvrp(4)' for the TC VlanTypeExt." + REVISION "200311210000Z" + DESCRIPTION + "Add vtpInternalVlanGrp to configure internal + VLANs' allocation policy and show the owner + application names." + REVISION "200308080000Z" + DESCRIPTION + "Split vtpConfigNotificationsGroup into two groups: + vtpConfigNotificationsGroupRev1 and + vtpConfigNotificationsGroup5. Write a new compliance + statement to list vtpConfigNotificationsGroupRev1 in + instead of vtpConfigNotificationsGroup in the + MANDATORY-GROUPS." + REVISION "200307110000Z" + DESCRIPTION + "Modify the description of the TC VlanIndex." + REVISION "200304160000Z" + DESCRIPTION + "Add support for VTP version 3 features. + -- Add enumerators and modify the 'DESCRIPTION' of 6 + existing objects: + vtpVersion, managementDomainLocalMode, + managementDomainConfigRevNumber, + managementDomainLastUpdater, + managementDomainLastChange, + managementDomainVersionInUse. + -- Add 3 new groups: vtpAuthGroup, + vtpDiscoverGroup, vtpDatabaseGroup." + REVISION "200204100000Z" + DESCRIPTION + "-- Add 4 new notifications/traps vtpLocalModeChanged, + vtpVersionInUseChanged, vtpVlanCreated and + vtpVlanDeleted. + -- Add 2 new objects vtpVlanCreatedNotifEnabled and + vtpVlanDeletedNotifEnabled to control the + generation of vtpVlanCreated and vtpVlanDeleted. + -- Use vtpNotificationsEnabled to control the + generation of vtpLocalModeChanged and + vtpVersionInUseChanged by grouping them in a + new group vtpConfigNotificationsGroup2. + -- Deprecate the object vlanTrunkPortsDot1qTag and + its related group." + REVISION "200202280000Z" + DESCRIPTION + "Deprecate the object, vlanTrunkPortDot1qTunnel." + REVISION "200108030000Z" + DESCRIPTION + "Add a new off(4) mode to managementDomainLocalMode." + REVISION "200102260000Z" + DESCRIPTION + "Deprecate read-only object vtpVlanEditTypeExt and + add a new read-create object vtpVlanEditTypeExt2. + Enable Notification groups." + REVISION "200102120000Z" + DESCRIPTION + "Added Remote SPAN (RSPAN) VLAN feature, VLAN + management features without supporting VTP protocol + and a new object to handle one-VLAN-editing." + REVISION "200009190000Z" + DESCRIPTION + "Added the mapping from VLAN ID to its corresponding + ifIndex" + REVISION "200004100000Z" + DESCRIPTION + "Added 4k VLAN editing and Dot1qTunnel support" + REVISION "200001060000Z" + DESCRIPTION + "Added 4k VLAN support" + REVISION "9902251130Z" + DESCRIPTION + "Added import of NOTIFICATION-GROUP" + REVISION "9901051130Z" + DESCRIPTION + "Added support for encapsulation type notApplicable" + REVISION "9805191130Z" + DESCRIPTION + "Added support for encapsulation type negotiation" + REVISION "9708081138Z" + DESCRIPTION + "Added Backup CRF object" + REVISION "9705091130Z" + DESCRIPTION + "Added ARE and STE hop counts." + REVISION "9702241115Z" + DESCRIPTION + "Added support for turning on VTP for Trunk cards." + REVISION "9701271730Z" + DESCRIPTION + "Added support for version 2 features." + REVISION "9609161230Z" + DESCRIPTION + "Updated the Token-Ring support." + REVISION "9607171230Z" + DESCRIPTION + "Updated to include objects in support of VTP pruning." + REVISION "9601181820Z" + DESCRIPTION + "Initial version of this MIB module." + ::= { ciscoMgmt 46 } + + +vtpMIBObjects OBJECT IDENTIFIER + ::= { ciscoVtpMIB 1 } + + +-- Textual Conventions + +VlanIndex ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The VLAN-id of a VLAN on ISL or 802.1q trunks. + + Modification of default parameters is allowed. + Implementations are allowed to restrict + the range of VLANs. + + For entities support up to 1024 VLANS. + VLANs above 1000 are reserved for default VLANs and + future use. Modification of default parameters is + allowed. Creation or deletion of VLANs above 1000 is not + allowed. + + For a new object which needs the vlan-id of a VLAN as + its SYNTAX, it is suggested to import VlanIndex from + Q-BRIDGE-MIB instead of importing this TC here in + CISCO-VTP-MIB." + SYNTAX Integer32 (0..4095) + +ManagementDomainIndex ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An arbitrary integer-value to uniquely identify a + management domain on the local system." + SYNTAX Integer32 (1..255) + +VlanType ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The type of a VLAN. + + Note that the 'ethernet' type, is used for any ethernet or + 802.3 VLAN, including an ATM Ethernet ELAN; and the + 'tokenRing' ('trCrf') type is used for each VLAN + representing a single logical 802.5 ring including an ATM + Token-Ring ELAN. + + The 'trCrf' type is used for token ring VLANs made up of + (at most) one transparently bridged LAN segment. + + The 'trBrf' type is used for VLANs which represent the + scope of many 'trCrf' VLANs all connected together via + source route bridging. The token ring 'trBrf' can be said + to represent the bridged broadcast domain." + SYNTAX INTEGER { + ethernet(1), + fddi(2), + tokenRing(3), -- also known as trCrf + fddiNet(4), + trNet(5), -- also known as trBrf + deprecated(6) + } + +VlanTypeExt ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The additional type information of VLAN. + vtpmanageable(0) An user defined VLAN which is + manageable through VTP protocol. + The value of this bit cannot be + changed. + internal(1) An internal VLAN created by the device. + Internal VLANs cannot be created or + deleted. The value of this bit cannot + be changed. + reserved(2) A VLAN reserved by the device. + Reserved VLANs cannot be created or + deleted. The value of this bit cannot + be changed. + rspan(3) A VLAN created to exclusively carry + the traffic for a Remote Switched + Port Analyzer (RSPAN). This bit can + only be set or cleared during the + VLAN creation. Once the VLAN is + created, the value of this bit cannot + be modified. + dynamicGvrp(4) A VLAN dynamically created by GVRP + (GARP VLAN Registration Protocol) + propagation. The value of this bit + cannot be changed." + + REFERENCE "RFC2674." + SYNTAX BITS { + vtpmanageable(0), + internal(1), + reserved(2), + rspan(3), + dynamicGvrp(4) + } +-- VTP status + +vtpStatus OBJECT IDENTIFIER + ::= { vtpMIBObjects 1 } + + +vtpVersion OBJECT-TYPE + SYNTAX INTEGER { + one(1), + two(2), + none(3), + three(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The version of VTP in use on the local system. A device + will report its version capability and not any particular + version in use on the device. If the device does not support + vtp, the version is none(3)." + ::= { vtpStatus 1 } + +vtpMaxVlanStorage OBJECT-TYPE + SYNTAX Integer32 (-1..1023) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An estimate of the maximum number of VLANs about which the + local system can recover complete VTP information after a + reboot. If the number of defined VLANs is greater than this + value, then the system can not act as a VTP Server. For a + device which has no means to calculate the estimated number, + this value is -1." + ::= { vtpStatus 2 } + +vtpNotificationsEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "An indication of whether the notifications/traps defined by + the vtpConfigNotificationsGroup, vtpConfigNotificationsGroup2, + and vtpConfigNotificationsGroup8 are enabled." + ::= { vtpStatus 3 } + +vtpVlanCreatedNotifEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "An indication of whether the notification should + be generated when a VLAN is created. + + If the value of this object is 'true' then the + vtpVlanCreated notification will be generated. + + If the value of this object is 'false' then the + vtpVlanCreated notification will not be generated." + ::= { vtpStatus 4 } + +vtpVlanDeletedNotifEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "An indication of whether the notification should + be generated when a VLAN is deleted. + + If the value of this object is 'true' then the + vtpVlanDeleted notification will be generated. + + If the value of this object is 'false' then the + vtpVlanDeleted notification will not be generated." + ::= { vtpStatus 5 } +-- VTP Management Domains + +vlanManagementDomains OBJECT IDENTIFIER + ::= { vtpMIBObjects 2 } + + +managementDomainTable OBJECT-TYPE + SYNTAX SEQUENCE OF ManagementDomainEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table containing information on the management domains + in which the local system is participating. Devices which + support only one management domain will support just one row + in this table, and will not let it be deleted nor let other + rows be created. Devices which support multiple management + domains will allow rows to be created and deleted, but will + not allow the last row to be deleted. If the device does + not support VTP, the table is read-only." + ::= { vlanManagementDomains 1 } + +managementDomainEntry OBJECT-TYPE + SYNTAX ManagementDomainEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information about the status of one management domain." + INDEX { managementDomainIndex } + ::= { managementDomainTable 1 } + +ManagementDomainEntry ::= SEQUENCE { + managementDomainIndex ManagementDomainIndex, + managementDomainName DisplayString, + managementDomainLocalMode INTEGER, + managementDomainConfigRevNumber Gauge32, + managementDomainLastUpdater IpAddress, + managementDomainLastChange DateAndTime, + managementDomainRowStatus RowStatus, + managementDomainTftpServer IpAddress, + managementDomainTftpPathname DisplayString, + managementDomainPruningState INTEGER, + managementDomainVersionInUse INTEGER, + managementDomainPruningStateOper INTEGER, + managementDomainAdminSrcIf SnmpAdminString, + managementDomainSourceOnlyMode TruthValue, + managementDomainOperSrcIf SnmpAdminString, + managementDomainConfigFile SnmpAdminString, + managementDomainLocalUpdaterType InetAddressType, + managementDomainLocalUpdater InetAddress, + managementDomainDeviceID SnmpAdminString +} + +managementDomainIndex OBJECT-TYPE + SYNTAX ManagementDomainIndex + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An arbitrary value to uniquely identify the management + domain on the local system." + ::= { managementDomainEntry 1 } + +managementDomainName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..32)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The management name of a domain in which the local system + is participating. The zero-length name corresponds to the + 'no management-domain' state which is the initial value at + installation-time if not configured otherwise. Note that + the zero-length name does not correspond to an operational + management domain, and a device does not send VTP + advertisements while in the 'no management-domain' state. A + device leaves the 'no management-domain' state when it + obtains a management-domain name, either through + configuration or through inheriting the management-domain + name from a received VTP advertisement. + + When the value of an existing instance of this object is + modified by network management, the local system should re- + initialize its VLAN information (for the given management + domain) as if it had just been configured with a management + domain name at installation time." + ::= { managementDomainEntry 2 } + +managementDomainLocalMode OBJECT-TYPE + SYNTAX INTEGER { + client(1), + server(2), + transparent(3), + off(4) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The local VTP mode in this management domain when + managementDomainVersionInUse is version1(1) or + version2(2). + + If managementDomainVersionInUse is version3(4), this + object has the same value with vtpDatabaseLocalMode + of VLAN database type. + + - 'client' indicates that the local system is acting + as a VTP client. + + - 'server' indicates that the local system is acting + as a VTP server. + + - 'transparent' indicates that the local system does + not generate or listen to VTP messages, but forwards + messages. This mode can also be set by the device + itself when the amount of VLAN information is too + large for it to hold in DRAM. + + - 'off' indicates that the local system does not + generate, listen to or forward any VTP messages." + ::= { managementDomainEntry 3 } + +managementDomainConfigRevNumber OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Configuration Revision Number as known by + the local device for this management domain when + managementDomainVersionInUse is version1(1) or + version2(2). + + If managementDomainVersionInUse is version3(4), this + object has the same value with vtpDatabaseRevisionNumber + of VLAN database type. + + This value is updated (if necessary) whenever a VTP + advertisement is received or generated. When in the + 'no management-domain' state, this value is 0." + ::= { managementDomainEntry 4 } + +managementDomainLastUpdater OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The IP-address (or one of them) of the VTP Server which + last updated the Configuration Revision Number, as indicated + in the most recently received VTP advertisement for this + management domain, when managementDomainVersionInUse is + version1(1) or version2(2). + + If managementDomainVersionInUse is version3(4), this object + has the value of 0.0.0.0. + + Before an advertisement has been received, this value is + 0.0.0.0." + ::= { managementDomainEntry 5 } + +managementDomainLastChange OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time at which the Configuration Revision Number was + (last) increased to its current value, as indicated in the + most recently received VTP advertisement for this management + domain when managementDomainVersionInUse is not version3(4) + or in the most recently received VTP VLAN database + advertisement for this management domain when + managementDomainVersionInUse is version3(4). + + The value 0x0000010100000000 indicates that the device which + last increased the Configuration Revision Number had no idea + of the date/time, or that no advertisement has been + received." + ::= { managementDomainEntry 6 } + +managementDomainRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of this conceptual row." + ::= { managementDomainEntry 7 } + +managementDomainTftpServer OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The IP address of a TFTP Server in/from which VTP VLAN + information for this management domain is to be + stored/retrieved. If the information is being locally + stored in NVRAM, this object should take the value 0.0.0.0." + ::= { managementDomainEntry 8 } + +managementDomainTftpPathname OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The complete pathname of the file at the TFTP Server + identified by the value of managementDomainTftpServer + in/from which VTP VLAN information for this management + domain is to be stored/retrieved. If the value of + corresponding instance of managementDomainTftpServer is + 0.0.0.0, the value of this object is ignored." + ::= { managementDomainEntry 9 } + +managementDomainPruningState OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "An indication of whether VTP pruning is enabled or disabled + in this managament domain. + + This object can only be modified, either when the + corresponding instance value of managementDomainVersionInUse + is 'version1' or 'version2' and the corresponding instance + value of managementDomainLocalMode is 'server', or when the + corresponding instance value of managementDomainVersionInUse + is 'version3' and the corresponding instance value of + managementDomainLocalMode is 'server' or 'client'." + ::= { managementDomainEntry 10 } + +managementDomainVersionInUse OBJECT-TYPE + SYNTAX INTEGER { + version1(1), + version2(2), + none(3), + version3(4) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The current version of the VTP that is in use by the + designated management domain. + + This object can be set to none(3) only when + vtpVersion is none(3)." + ::= { managementDomainEntry 11 } + +managementDomainPruningStateOper OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates whether VTP pruning is operationally enabled or + disabled in this managament domain." + ::= { managementDomainEntry 12 } + +managementDomainAdminSrcIf OBJECT-TYPE + SYNTAX SnmpAdminString + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The object specifies the interface to be used as the + preferred source interface for the VTP IP updater address. + + A zero length value indicates that a source interface is not + specified." + ::= { managementDomainEntry 13 } + +managementDomainSourceOnlyMode OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The object specifies whether to use only the IP address of + managementDomainAdminSrcIf as the VTP IP updater address. + + 'true' indicates to only use the IP address of + managementDomainAdminSrcIf as the VTP IP + updater address. + + 'false' indicates to use the IP address of + managementDomainAdminSrcIf as the VTP IP + updater address if managementDomainAdminSrcIf + is configured with an IP address. Otherwise, the + first available IP address of the system will + be used." + DEFVAL { false } + ::= { managementDomainEntry 14 } + +managementDomainOperSrcIf OBJECT-TYPE + SYNTAX SnmpAdminString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object indicates the interface used as the + preferred source interface for the VTP IP updater address. + + A zero length string indicates that a source interface is not + available." + ::= { managementDomainEntry 15 } + +managementDomainConfigFile OBJECT-TYPE + SYNTAX SnmpAdminString + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The object specifies the file name where VTP configuration + is stored in the format of or :[]. + + can be (but not limited to): flash, bootflash, + slot0, slot1, disk0." + ::= { managementDomainEntry 16 } + +managementDomainLocalUpdaterType OBJECT-TYPE + SYNTAX InetAddressType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object indicates the type of the Internet address + of the preferred source interface for the VTP IP updater. + + The value of this object is 'unknown' if + managementDomainVersionInUse is 'version3' or + managementDomainLocalMode is not 'server'." + ::= { managementDomainEntry 17 } + +managementDomainLocalUpdater OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object indicates the Internet address of the + preferred source interface for the VTP IP updater." + ::= { managementDomainEntry 18 } + +managementDomainDeviceID OBJECT-TYPE + SYNTAX SnmpAdminString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object indicates a value that uniquely identifies + this device within a VTP Domain. + + The value of this object is zero length string if + managementDomainVersionInUse is not 'version3'." + ::= { managementDomainEntry 19 } + + +-- VLAN information + +vlanInfo OBJECT IDENTIFIER + ::= { vtpMIBObjects 3 } + +-- Global information on current VLANs +-- +-- This information is maintained by VTP Clients and VTP Servers + +vtpVlanTable OBJECT-TYPE + SYNTAX SEQUENCE OF VtpVlanEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains information on the VLANs which + currently exist." + ::= { vlanInfo 1 } + +vtpVlanEntry OBJECT-TYPE + SYNTAX VtpVlanEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information about one current VLAN. The + managementDomainIndex value in the INDEX clause indicates + which management domain the VLAN is in." + INDEX { + managementDomainIndex, + vtpVlanIndex + } + ::= { vtpVlanTable 1 } + +VtpVlanEntry ::= SEQUENCE { + vtpVlanIndex VlanIndex, + vtpVlanState INTEGER, + vtpVlanType VlanType, + vtpVlanName DisplayString, + vtpVlanMtu Integer32, + vtpVlanDot10Said OCTET STRING, + vtpVlanRingNumber Integer32, + vtpVlanBridgeNumber Integer32, + vtpVlanStpType INTEGER, + vtpVlanParentVlan VlanIndex, + vtpVlanTranslationalVlan1 VlanIndex, + vtpVlanTranslationalVlan2 VlanIndex, + vtpVlanBridgeType INTEGER, + vtpVlanAreHopCount Integer32, + vtpVlanSteHopCount Integer32, + vtpVlanIsCRFBackup TruthValue, + vtpVlanTypeExt VlanTypeExt, + vtpVlanIfIndex InterfaceIndexOrZero +} + +vtpVlanIndex OBJECT-TYPE + SYNTAX VlanIndex + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The VLAN-id of this VLAN on ISL or 802.1q trunks." + ::= { vtpVlanEntry 1 } + +vtpVlanState OBJECT-TYPE + SYNTAX INTEGER { + operational(1), + suspended(2), + mtuTooBigForDevice(3), + mtuTooBigForTrunk(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The state of this VLAN. + + The state 'mtuTooBigForDevice' indicates that this device + cannot participate in this VLAN because the VLAN's MTU is + larger than the device can support. + + The state 'mtuTooBigForTrunk' indicates that while this + VLAN's MTU is supported by this device, it is too large for + one or more of the device's trunk ports." + ::= { vtpVlanEntry 2 } + +vtpVlanType OBJECT-TYPE + SYNTAX VlanType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of this VLAN." + ::= { vtpVlanEntry 3 } + +vtpVlanName OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of this VLAN. This name is used as the ELAN-name + for an ATM LAN-Emulation segment of this VLAN." + ::= { vtpVlanEntry 4 } + +vtpVlanMtu OBJECT-TYPE + SYNTAX Integer32 (1500..18190) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The MTU size on this VLAN, defined as the size of largest + MAC-layer (information field portion of the) data frame + which can be transmitted on the VLAN." + ::= { vtpVlanEntry 5 } + +vtpVlanDot10Said OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (4)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of the 802.10 SAID field for this VLAN." + ::= { vtpVlanEntry 6 } + +vtpVlanRingNumber OBJECT-TYPE + SYNTAX Integer32 (0..4095) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The ring number of this VLAN. This object is only + instantiated when the value of the corresponding instance of + vtpVlanType has a value of 'fddi' or 'tokenRing' and Source + Routing is in use on this VLAN." + ::= { vtpVlanEntry 7 } + +vtpVlanBridgeNumber OBJECT-TYPE + SYNTAX Integer32 (0..15) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The bridge number of the VTP-capable switches for this + VLAN. This object is only instantiated for VLANs that are + involved with emulating token ring segments." + ::= { vtpVlanEntry 8 } + +vtpVlanStpType OBJECT-TYPE + SYNTAX INTEGER { + ieee(1), + ibm(2), + hybrid(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of the Spanning Tree Protocol (STP) running on + this VLAN. This object is only instanciated when the + value of the corresponding instance of vtpVlanType has a + value of 'fddiNet' or 'trNet'. + + The value returned by this object depends upon the value + of the corresponding instance of vtpVlanEditStpType. + + - 'ieee' indicates IEEE STP is running exclusively. + + - 'ibm' indicates IBM STP is running exclusively. + + - 'hybrid' indicates a STP that allows a combination of + IEEE and IBM is running. + + The 'hybrid' STP type results from tokenRing/fddi VLANs + that are children of this trNet/fddiNet parent VLAN being + configured in a combination of SRT and SRB + vtpVlanBridgeTypes while the instance of + vtpVlanEditStpType that corresponds to this object is set + to 'auto'." + ::= { vtpVlanEntry 9 } + +vtpVlanParentVlan OBJECT-TYPE + SYNTAX VlanIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The parent VLAN for this VLAN. This object is only + instantiated when the value of the corresponding instance of + vtpVlanType has a value of 'fddi' or 'tokenRing' and Source + Routing is in use on this VLAN. The parent VLAN must have + a vtpVlanType value of fddiNet(4) or trNet(5), + respectively." + ::= { vtpVlanEntry 10 } + +vtpVlanTranslationalVlan1 OBJECT-TYPE + SYNTAX VlanIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A VLAN to which this VLAN is being translational-bridged. + If this value and the corresponding instance of + vtpVlanTranslationalVlan2 are both zero, then this VLAN is + not being translational-bridged." + ::= { vtpVlanEntry 11 } + +vtpVlanTranslationalVlan2 OBJECT-TYPE + SYNTAX VlanIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Another VLAN, i.e., other than that indicated by + vtpVlanTranslationalVlan1, to which this VLAN is being + translational-bridged. If this value and the corresponding + instance of vtpVlanTranslationalVlan1 are both zero, then + this VLAN is not being translational-bridged." + ::= { vtpVlanEntry 12 } + +vtpVlanBridgeType OBJECT-TYPE + SYNTAX INTEGER { + srt(1), + srb(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of the Source Route bridging mode in use on this + VLAN. This object is only instantiated when the value of + the corresponding instance of vtpVlanType has a value of + fddi(2) or tokenRing(3) and Source Routing is in use on + this VLAN." + ::= { vtpVlanEntry 13 } + +vtpVlanAreHopCount OBJECT-TYPE + SYNTAX Integer32 (1..13) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum number of bridge hops allowed in + All Routes Explorer frames on this VLAN. This + object is only instantiated when the value of the + corresponding instance of vtpVlanType has a value of fddi(2) + or tokenRing(3) and Source Routing is in use on this VLAN." + ::= { vtpVlanEntry 14 } + +vtpVlanSteHopCount OBJECT-TYPE + SYNTAX Integer32 (1..13) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum number of bridge hops allowed in + Spanning Tree Explorer frames on this VLAN. This + object is only instantiated when the value of the + corresponding instance of vtpVlanType has a value of fddi(2) + or tokenRing(3) and Source Routing is in use on this VLAN." + ::= { vtpVlanEntry 15 } + +vtpVlanIsCRFBackup OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "True if this VLAN is of type trCrf and also is acting as + a backup trCrf for the ISL distributed BRF" + ::= { vtpVlanEntry 16 } + +vtpVlanTypeExt OBJECT-TYPE + SYNTAX VlanTypeExt + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The additional type information of this VLAN." + ::= { vtpVlanEntry 17 } + +vtpVlanIfIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of the ifIndex corresponding to this VLAN ID. + If the VLAN ID does not have its corresponding interface, + this object has the value of zero." + ::= { vtpVlanEntry 18 } + + +internalVlanInfo OBJECT IDENTIFIER + ::= { vlanInfo 2 } + + +vtpInternalVlanAllocPolicy OBJECT-TYPE + SYNTAX INTEGER { + ascending(1), + descending(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The internal VLAN allocation policy. + + 'ascending' - internal VLANs are allocated + starting from a lowwer VLAN ID and + upwards. + 'descending' - internal VLANs are allocated + starting from a higher VLAN ID and + downwards." + ::= { internalVlanInfo 1 } + +vtpInternalVlanTable OBJECT-TYPE + SYNTAX SEQUENCE OF VtpInternalVlanEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A vtpInternalVlanTable entry contains + information on an existing internal + VLAN. It is internally created by the + device for a specific application program + and hence owned by the application. + It cannot be modified or deleted by (local + or network) management." + ::= { internalVlanInfo 2 } + +vtpInternalVlanEntry OBJECT-TYPE + SYNTAX VtpInternalVlanEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information about one current internal + VLAN." + INDEX { + managementDomainIndex, + vtpVlanIndex + } + ::= { vtpInternalVlanTable 1 } + +VtpInternalVlanEntry ::= SEQUENCE { + vtpInternalVlanOwner SnmpAdminString +} + +vtpInternalVlanOwner OBJECT-TYPE + SYNTAX SnmpAdminString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The program name of the internal VLAN's + owner application. This internal VLAN + is allocated by the device specifically + for this application and no one else + could create, modify or delete this + VLAN." + ::= { vtpInternalVlanEntry 1 } + + +-- Modification of Global VLAN Information +-- +-- To change the global information on current VLANs, including +-- creating, modifying or deleting them, +-- . the current VLAN information is copied to the "Edit buffer", +-- . the information in the Edit buffer is modified as appropriate, +-- . an 'apply' is invoked to attempt to instanciate the modified +-- contents of the Edit Buffer as the new global VLAN information. +-- +-- Only one manager can edit the Edit Buffer at a time. So, a +-- request to copy the current VLAN information into the Edit Buffer +-- must fail if the Edit Buffer is already in use (i.e., is not empty). +-- Thus, concurrent attempts by multiple managers to gain use of the +-- Edit Buffer are resolved according to whichever of them succeeds +-- in performing a successful copy. An OwnerString object provides +-- information on which manager currently has access. +-- +-- Ownership of the Edit Buffer terminates when a NMS explicitly +-- releases it, or when a deadman-timer expires. The deadman-timer +-- has a fixed expiry interval of 5 minutes. The deadman-timer is +-- automatically started on a successful copy operation. The +-- restartTimer operation allows an NMS to restart the deadman-timer +-- if it wishes to retain ownership of the Edit Buffer for longer +-- than 5 minutes. The deadman-timer ceases when the apply operation +-- is invoked, and is restarted when the apply operation terminates. +-- Restarting the deadman-timer after termination of the apply +-- operation allows the results of the apply operation to be retained +-- until the requesting manager has retrieved them, but for only a +-- limited amount of time. +-- +-- When managementDomainVersionInUse is version1(1) or version2(2), +-- the local device with managementDomainLocalMode as server(2) +-- could change the global VLAN configuration by editing the VLAN +-- information in the edit buffer and then apply it. However, +-- when managementDomainVersionInUse is in version3(4), there +-- are two different VTP servers, the primary server and the +-- secondary server. The global VLAN configuration could only +-- be changed by a primary server for VLAN database. The +-- secondary server may still do the 'copy' operation and edit +-- the VLAN information in the edit buffer. But in order to make +-- a possibly successful 'apply' operation, the local device must +-- be a VLAN database primary server. Otherwise, the 'apply' will +-- fail and vtpVlanApplyStatus will be set to the error status +-- 'notPrimaryServer'. + +vlanEdit OBJECT IDENTIFIER + ::= { vtpMIBObjects 4 } + + +vtpEditControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF VtpEditControlEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides the means to control the editing of the + VLANs for a particular management domain. Each and every + entry in this table augments its corresponding entry in the + managementDomainTable; thus, an entry in this table is + created/deleted only as a by-product of creating/deleting an + entry in the managementDomainTable." + ::= { vlanEdit 1 } + +vtpEditControlEntry OBJECT-TYPE + SYNTAX VtpEditControlEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Control information for editing the VLANs in one management + domain." + AUGMENTS { managementDomainEntry } + ::= { vtpEditControlTable 1 } + +VtpEditControlEntry ::= SEQUENCE { + vtpVlanEditOperation INTEGER, + vtpVlanApplyStatus INTEGER, + vtpVlanEditBufferOwner OwnerString, + vtpVlanEditConfigRevNumber Gauge32, + vtpVlanEditModifiedVlan VlanIndex +} + +vtpVlanEditOperation OBJECT-TYPE + SYNTAX INTEGER { + none(1), + copy(2), + apply(3), + release(4), + restartTimer(5) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object always has the value 'none' when read. When + written, each value causes the appropriate action: + + 'copy' - causes the creation of rows in the + vtpVlanEditTable exactly corresponding to the current global + VLAN information for this management domain. If the Edit + Buffer (for this management domain) is not currently empty, + a copy operation fails. A successful copy operation starts + the deadman-timer. + + 'apply' - first performs a consistent check on the the + modified information contained in the Edit Buffer, and if + consistent, then tries to instanciate the modified + information as the new global VLAN information. Note that + an empty Edit Buffer (for the management domain) would + always result in an inconsistency since the default VLANs + are required to be present. + + 'release' - flushes the Edit Buffer (for this management + domain), clears the Owner information, and aborts the + deadman-timer. A release is generated automatically if the + deadman-timer ever expires. + + 'restartTimer' - restarts the deadman-timer. + + 'none' - no operation is performed." + ::= { vtpEditControlEntry 1 } + +vtpVlanApplyStatus OBJECT-TYPE + SYNTAX INTEGER { + inProgress(1), + succeeded(2), + configNumberError(3), + inconsistentEdit(4), + tooBig(5), + localNVStoreFail(6), + remoteNVStoreFail(7), + editBufferEmpty(8), + someOtherError(9), + notPrimaryServer(10) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current status of an 'apply' operation to instanciate + the Edit Buffer as the new global VLAN information (for this + management domain). If no apply is currently active, the + status represented is that of the most recently completed + apply. The possible values are: + + inProgress - 'apply' operation in progress; + + succeeded - the 'apply' was successful (this value is + also used when no apply has been invoked since the + last time the local system restarted); + + configNumberError - the apply failed because the value of + vtpVlanEditConfigRevNumber was less or equal to + the value of current value of + managementDomainConfigRevNumber; + + inconsistentEdit - the apply failed because the modified + information was not self-consistent; + + tooBig - the apply failed because the modified + information was too large to fit in this VTP + Server's non-volatile storage location; + + localNVStoreFail - the apply failed in trying to store + the new information in a local non-volatile + storage location; + + remoteNVStoreFail - the apply failed in trying to store + the new information in a remote non-volatile + storage location; + + editBufferEmpty - the apply failed because the Edit + Buffer was empty (for this management domain). + + someOtherError - the apply failed for some other reason + (e.g., insufficient memory). + + notPrimaryServer - the apply failed because the local + device is not a VTP primary server for VLAN + database type when managementDomainVersionInUse + is version3(4)." + ::= { vtpEditControlEntry 2 } + +vtpVlanEditBufferOwner OBJECT-TYPE + SYNTAX OwnerString + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The management station which is currently using the Edit + Buffer for this management domain. When the Edit Buffer for + a management domain is not currently in use, the value of + this object is the zero-length string. Note that it is also + the zero-length string if a manager fails to set this object + when invoking a copy operation." + ::= { vtpEditControlEntry 3 } + +vtpVlanEditConfigRevNumber OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The Configuration Revision Number to be used for the next + apply operation. This value is initialized (by the agent) + on a copy operation to be one greater than the value of + managementDomainConfigRevNumber. On an apply, if the + number is less or equal to the value of + managementDomainConfigRevNumber, then the apply fails. + The value can be modified (increased) by network management + before an apply to ensure that an apply does not fail for + this reason. + + This object is used to allow management control over whether + a configuration revision received via a VTP advertisement + after a copy operation but before the succeeding apply + operation is lost by being overwritten by the (local) edit + operation. By default, the apply operation will fail in + this situation. By increasing this object's value after the + copy but before the apply, management can control whether + the apply is to succeed (with the update via VTP + advertisement being lost)." + ::= { vtpEditControlEntry 4 } + +vtpVlanEditModifiedVlan OBJECT-TYPE + SYNTAX VlanIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The VLAN-id of the modified VLAN in the Edit Buffer. + If the object has the value of zero, any VLAN can + be edited. If the value of the object is not zero, + only this VLAN can be edited. + + The object's value is reset to zero after a successful + 'apply' operation or a 'release' operation. + + This object is only supported for devices which allow + only one VLAN editing for each 'apply' operation. For + devices which allow multiple VLAN editing for each + 'apply' operation, this object is not supported." + ::= { vtpEditControlEntry 5 } + + + +vtpVlanEditTable OBJECT-TYPE + SYNTAX SEQUENCE OF VtpVlanEditEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table which contains the information in the Edit + Buffers, one Edit Buffer per management domain. The + information for a particular management domain is + initialized, by a 'copy' operation, to be the current global + VLAN information for that management domain. After + initialization, editing can be performed to add VLANs, + delete VLANs, or modify their global parameters. The + information as modified through editing is local to this + Edit Buffer. An apply operation using the + vtpVlanEditOperation object is necessary to instanciate the + modified information as the new global VLAN information for + that management domain. + + To use the Edit Buffer, a manager acts as follows: + + 1. ensures the Edit Buffer for a management domain is empty, + i.e., there are no rows in this table for this management + domain. + + 2. issues a SNMP set operation which sets + vtpVlanEditOperation to 'copy', and vtpVlanEditBufferOwner + to its own identifier (e.g., its own IP address). + + 3. if this set operation is successful, proceeds to edit the + information in the vtpVlanEditTable. + + 4. if and when the edited information is to be instantiated, + issues a SNMP set operation which sets vtpVlanEditOperation + to 'apply'. + + 5. issues retrieval requests to obtain the value of + vtpVlanApplyStatus, until the result of the apply is + determined. + + 6. releases the Edit Buffer by issuing a SNMP set operation + which sets vtpVlanEditOperation to 'release'. + + Note that the information contained in this table is not + saved across agent reboots." + ::= { vlanEdit 2 } + +vtpVlanEditEntry OBJECT-TYPE + SYNTAX VtpVlanEditEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information about one VLAN in the Edit Buffer for a + particular management domain." + INDEX { + managementDomainIndex, + vtpVlanEditIndex + } + ::= { vtpVlanEditTable 1 } + +VtpVlanEditEntry ::= SEQUENCE { + vtpVlanEditIndex VlanIndex, + vtpVlanEditState INTEGER, + vtpVlanEditType VlanType, + vtpVlanEditName DisplayString, + vtpVlanEditMtu Integer32, + vtpVlanEditDot10Said OCTET STRING, + vtpVlanEditRingNumber Integer32, + vtpVlanEditBridgeNumber Integer32, + vtpVlanEditStpType INTEGER, + vtpVlanEditParentVlan VlanIndex, + vtpVlanEditRowStatus RowStatus, + vtpVlanEditTranslationalVlan1 VlanIndex, + vtpVlanEditTranslationalVlan2 VlanIndex, + vtpVlanEditBridgeType INTEGER, + vtpVlanEditAreHopCount Integer32, + vtpVlanEditSteHopCount Integer32, + vtpVlanEditIsCRFBackup TruthValue, + vtpVlanEditTypeExt VlanTypeExt, + vtpVlanEditTypeExt2 VlanTypeExt +} + +vtpVlanEditIndex OBJECT-TYPE + SYNTAX VlanIndex + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The VLAN-id which this VLAN would have on ISL or + 802.1q trunks." + ::= { vtpVlanEditEntry 1 } + +vtpVlanEditState OBJECT-TYPE + SYNTAX INTEGER { + operational(1), + suspended(2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The state which this VLAN would have." + DEFVAL { operational } + ::= { vtpVlanEditEntry 2 } + +vtpVlanEditType OBJECT-TYPE + SYNTAX VlanType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The type which this VLAN would have. + An implementation may restrict access to this object." + DEFVAL { ethernet } + ::= { vtpVlanEditEntry 3 } + +vtpVlanEditName OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..32)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The name which this VLAN would have. This name would be + used as the ELAN-name for an ATM LAN-Emulation segment of + this VLAN. + + An implementation may restrict access to this object." + ::= { vtpVlanEditEntry 4 } + +vtpVlanEditMtu OBJECT-TYPE + SYNTAX Integer32 (1500..18190) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The MTU size which this VLAN would have, defined as the + size of largest MAC-layer (information field portion of the) + data frame which can be transmitted on the VLAN. + + An implementation may restrict access to this object." + DEFVAL { 1500 } + ::= { vtpVlanEditEntry 5 } + +vtpVlanEditDot10Said OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (4)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The value of the 802.10 SAID field which would be used for + this VLAN. + + An implementation may restrict access to this object." + ::= { vtpVlanEditEntry 6 } + +vtpVlanEditRingNumber OBJECT-TYPE + SYNTAX Integer32 (0..4095) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The ring number which would be used for this VLAN. This + object is only instantiated when the value of the + corresponding instance of vtpVlanEditType has a value of + 'fddi' or 'tokenRing' and Source Routing is in use on + this VLAN." + ::= { vtpVlanEditEntry 7 } + +vtpVlanEditBridgeNumber OBJECT-TYPE + SYNTAX Integer32 (0..15) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The bridge number of the VTP-capable switches which would + be used for this VLAN. This object is only instantiated + when the value of the corresponding instance of + vtpVlanEditType has a value of fddiNet(4) or trNet(5)." + ::= { vtpVlanEditEntry 8 } + +vtpVlanEditStpType OBJECT-TYPE + SYNTAX INTEGER { + ieee(1), + ibm(2), + auto(3) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The type of the Spanning Tree Protocol which would be + running on this VLAN. This object is only instantiated + when the value of the corresponding instance of + vtpVlanEditType has a value of fddiNet(4) or trNet(5). + + If 'ieee' is selected, the STP that runs will be IEEE. + + If 'ibm' is selected, the STP that runs will be IBM. + + If 'auto' is selected, the STP that runs will be + dependant on the values of vtpVlanEditBridgeType for all + children tokenRing/fddi type VLANs. This will result in + a 'hybrid' STP (see vtpVlanStpType)." + ::= { vtpVlanEditEntry 9 } + +vtpVlanEditParentVlan OBJECT-TYPE + SYNTAX VlanIndex + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The VLAN index of the VLAN which would be the parent for + this VLAN. This object is only instantiated when the value + of the corresponding instance of vtpVlanEditType has a value + of 'fddi' or 'tokenRing' and Source Routing is in use on + this VLAN. The parent VLAN must have a vtpVlanEditType + value of fddiNet(4) or trNet(5), respectively." + ::= { vtpVlanEditEntry 10 } + +vtpVlanEditRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of this row. Any and all columnar objects in an + existing row can be modified irrespective of the status of + the row. + + A row is not qualified for activation until instances of at + least its vtpVlanEditType, vtpVlanEditName and + vtpVlanEditDot10Said columns have appropriate values. + + The management station should endeavor to make all rows + consistent in the table before 'apply'ing the buffer. An + inconsistent entry in the table will cause the entire + buffer to be rejected with the vtpVlanApplyStatus object + set to the appropriate error value." + ::= { vtpVlanEditEntry 11 } + +vtpVlanEditTranslationalVlan1 OBJECT-TYPE + SYNTAX VlanIndex + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A VLAN to which this VLAN would be translational-bridged. + If this value and the corresponding instance of + vtpVlanTranslationalVlan2 are both zero, then this VLAN + would not be translational-bridged. + + An implementation may restrict access to this object." + DEFVAL { 0 } + ::= { vtpVlanEditEntry 12 } + +vtpVlanEditTranslationalVlan2 OBJECT-TYPE + SYNTAX VlanIndex + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Another VLAN, i.e., other than that indicated by + vtpVlanEditTranslationalVlan1, to which this VLAN would be + translational-bridged. If this value and the corresponding + instance of vtpVlanTranslationalVlan1 are both zero, then + this VLAN would not be translational-bridged. + + An implementation may restrict access to this object." + DEFVAL { 0 } + ::= { vtpVlanEditEntry 13 } + +vtpVlanEditBridgeType OBJECT-TYPE + SYNTAX INTEGER { + srt(1), + srb(2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The type of Source Route bridging mode which would be in + use on this VLAN. This object is only instantiated when + the value of the corresponding instance of vtpVlanEditType + has a value of fddi(2) or tokenRing(3) and Source Routing + is in use on this VLAN." + ::= { vtpVlanEditEntry 14 } + +vtpVlanEditAreHopCount OBJECT-TYPE + SYNTAX Integer32 (1..13) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The maximum number of bridge hops allowed in + All Routes Explorer frames on this VLAN. This + object is only instantiated when the value of the + corresponding instance of vtpVlanType has a value of fddi(2) + or tokenRing(3) and Source Routing is in use on this VLAN." + ::= { vtpVlanEditEntry 15 } + +vtpVlanEditSteHopCount OBJECT-TYPE + SYNTAX Integer32 (1..13) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The maximum number of bridge hops allowed in + Spanning Tree Explorer frames on this VLAN. This + object is only instantiated when the value of the + corresponding instance of vtpVlanType has a value of fddi(2) + or tokenRing(3) and Source Routing is in use on this VLAN." + ::= { vtpVlanEditEntry 16 } + +vtpVlanEditIsCRFBackup OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "True if this VLAN is of type trCrf and also is acting as + a backup trCrf for the ISL distributed BRF. This object is + only instantiated when the value of the corresponding + instance of vtpVlanEditType has a value of tokenRing(3)." + ::= { vtpVlanEditEntry 17 } + +vtpVlanEditTypeExt OBJECT-TYPE + SYNTAX VlanTypeExt + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The additional type information of this VLAN. + vtpVlanEditTypeExt object is superseded by vtpVlanEditTypeExt2." + ::= { vtpVlanEditEntry 18 } + +vtpVlanEditTypeExt2 OBJECT-TYPE + SYNTAX VlanTypeExt + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The additional type information of this VLAN. + The VlanTypeExt TC specifies which bits may + be written by a management application. + The agent should provide a default value." + ::= { vtpVlanEditEntry 19 } + + + +vtpVlanLocalShutdownTable OBJECT-TYPE + SYNTAX SEQUENCE OF VtpVlanLocalShutdownEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Ths table contains the VLAN local shutdown + information within management domain." + ::= { vlanEdit 3 } + +vtpVlanLocalShutdownEntry OBJECT-TYPE + SYNTAX VtpVlanLocalShutdownEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing VLAN local shutdown information for a + particular VLAN in the management domain. + + An entry is created if a VLAN which supports local shutdown + has been created. + + An entry is deleted if a VLAN which supports local shutdown + has been removed." + INDEX { + managementDomainIndex, + vtpVlanIndex + } + ::= { vtpVlanLocalShutdownTable 1 } + +VtpVlanLocalShutdownEntry ::= SEQUENCE { + vtpVlanLocalShutdown INTEGER +} + +vtpVlanLocalShutdown OBJECT-TYPE + SYNTAX INTEGER { + up(1), + down(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The object specifies the VLAN local shutdown state." + ::= { vtpVlanLocalShutdownEntry 1 } + + +-- VTP Statistics + +vtpStats OBJECT IDENTIFIER + ::= { vtpMIBObjects 5 } + + +vtpStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF VtpStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of VTP statistics." + ::= { vtpStats 1 } + +vtpStatsEntry OBJECT-TYPE + SYNTAX VtpStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "VTP statistics for one management domain." + AUGMENTS { managementDomainEntry } + ::= { vtpStatsTable 1 } + +VtpStatsEntry ::= SEQUENCE { + vtpInSummaryAdverts Counter32, + vtpInSubsetAdverts Counter32, + vtpInAdvertRequests Counter32, + vtpOutSummaryAdverts Counter32, + vtpOutSubsetAdverts Counter32, + vtpOutAdvertRequests Counter32, + vtpConfigRevNumberErrors Counter32, + vtpConfigDigestErrors Counter32 +} + +vtpInSummaryAdverts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of VTP Summary Adverts received for this + management domain." + ::= { vtpStatsEntry 1 } + +vtpInSubsetAdverts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of VTP Subset Adverts received for this + management domain." + ::= { vtpStatsEntry 2 } + +vtpInAdvertRequests OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of VTP Advert Requests received for this + management domain." + ::= { vtpStatsEntry 3 } + +vtpOutSummaryAdverts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of VTP Summary Adverts sent for this + management domain." + ::= { vtpStatsEntry 4 } + +vtpOutSubsetAdverts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of VTP Subset Adverts sent for this + management domain." + ::= { vtpStatsEntry 5 } + +vtpOutAdvertRequests OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of VTP Advert Requests sent for this + management domain." + ::= { vtpStatsEntry 6 } + +vtpConfigRevNumberErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of occurrences of configuration revision number + errors for this management domain. A configuration revision + number error occurs when a device receives a VTP + advertisement for which: + + - the advertisement's Configuration Revision Number is the + same as the current locally-held value, and + + - the advertisement's digest value is different from the + current locally-held value." + ::= { vtpStatsEntry 7 } + +vtpConfigDigestErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of occurrences of configuration digest errors + for this management domain. A configuration digest error + occurs when a device receives a VTP advertisement for which: + + - the advertisement's Configuration Revision Number is + greater than the current locally-held value, and + + - the advertisement's digest value computed by the + receiving device does not match the checksum in the + summary advertisement that was received earlier. This + can happen, for example, if there is a mismatch in VTP + passwords between the VTP devices." + ::= { vtpStatsEntry 8 } + + +-- Trunk Ports + +vlanTrunkPorts OBJECT IDENTIFIER + ::= { vtpMIBObjects 6 } + + +vlanTrunkPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF VlanTrunkPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table containing information on the local system's VLAN + trunk ports." + ::= { vlanTrunkPorts 1 } + +vlanTrunkPortEntry OBJECT-TYPE + SYNTAX VlanTrunkPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information about one trunk port." + INDEX { vlanTrunkPortIfIndex } + ::= { vlanTrunkPortTable 1 } + +VlanTrunkPortEntry ::= SEQUENCE { + vlanTrunkPortIfIndex InterfaceIndex, + vlanTrunkPortManagementDomain ManagementDomainIndex, + vlanTrunkPortEncapsulationType INTEGER, + vlanTrunkPortVlansEnabled OCTET STRING, + vlanTrunkPortNativeVlan VlanIndex, + vlanTrunkPortRowStatus RowStatus, + vlanTrunkPortInJoins Counter32, + vlanTrunkPortOutJoins Counter32, + vlanTrunkPortOldAdverts Counter32, + vlanTrunkPortVlansPruningEligible OCTET STRING, + vlanTrunkPortVlansXmitJoined OCTET STRING, + vlanTrunkPortVlansRcvJoined OCTET STRING, + vlanTrunkPortDynamicState INTEGER, + vlanTrunkPortDynamicStatus INTEGER, + vlanTrunkPortVtpEnabled TruthValue, + vlanTrunkPortEncapsulationOperType INTEGER, + vlanTrunkPortVlansEnabled2k OCTET STRING, + vlanTrunkPortVlansEnabled3k OCTET STRING, + vlanTrunkPortVlansEnabled4k OCTET STRING, + vtpVlansPruningEligible2k OCTET STRING, + vtpVlansPruningEligible3k OCTET STRING, + vtpVlansPruningEligible4k OCTET STRING, + vlanTrunkPortVlansXmitJoined2k OCTET STRING, + vlanTrunkPortVlansXmitJoined3k OCTET STRING, + vlanTrunkPortVlansXmitJoined4k OCTET STRING, + vlanTrunkPortVlansRcvJoined2k OCTET STRING, + vlanTrunkPortVlansRcvJoined3k OCTET STRING, + vlanTrunkPortVlansRcvJoined4k OCTET STRING, + vlanTrunkPortDot1qTunnel INTEGER, + vlanTrunkPortVlansActiveFirst2k Cisco2KVlanList, + vlanTrunkPortVlansActiveSecond2k Cisco2KVlanList +} + +vlanTrunkPortIfIndex OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The value of ifIndex for the interface corresponding to + this trunk port." + ::= { vlanTrunkPortEntry 1 } + +vlanTrunkPortManagementDomain OBJECT-TYPE + SYNTAX ManagementDomainIndex + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The value of managementDomainIndex for the management + domain on this trunk port. Devices which support only one + management domain will support this object read-only." + ::= { vlanTrunkPortEntry 2 } + +vlanTrunkPortEncapsulationType OBJECT-TYPE + SYNTAX INTEGER { + isl(1), + dot10(2), + lane(3), + dot1Q(4), + negotiate(5) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The type of VLAN encapsulation desired to be used on this + trunk port. It is either a particular type, or 'negotiate' + meaning whatever type results from the negotiation. + negotiate(5) is not allowed if the port does not support + negotiation or if its vlanTrunkPortDynamicState is set to + on(1) or onNoNegotiate(5). Whether writing to this object + in order to modify the encapsulation is supported is both + device and interface specific." + ::= { vlanTrunkPortEntry 3 } + +vlanTrunkPortVlansEnabled OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (128)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN in the + management domain on this trunk port. The first octet + corresponds to VLANs with VlanIndex values of 0 through 7; + the second octet to VLANs 8 through 15; etc. The most + significant bit of each octet corresponds to the lowest + value VlanIndex in that octet. If the bit corresponding to + a VLAN is set to '1', then the local system is enabled for + sending and receiving frames on that VLAN; if the bit is set + to '0', then the system is disabled from sending and + receiving frames on that VLAN. + + To avoid conflicts between overlapping partial updates by + multiple managers, i.e., updates which modify only a portion + of an instance of this object (e.g., enable/disable a single + VLAN on the trunk port), any SNMP Set operation accessing an + instance of this object should also write the value of + vlanTrunkPortSetSerialNo." + ::= { vlanTrunkPortEntry 4 } + +vlanTrunkPortNativeVlan OBJECT-TYPE + SYNTAX VlanIndex + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The VlanIndex of the VLAN which is represented by native + frames on this trunk port. For trunk ports not supporting + the sending and receiving of native frames, this value + should be set to zero." + ::= { vlanTrunkPortEntry 5 } + +vlanTrunkPortRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of this row. In some circumstances, the + creation of a row in this table is needed to enable the + appropriate trunking/tagging protocol on the port, to enable + the use of VTP on the port, and to assign the port to the + appropriate management domain. In other circumstances, rows + in this table will be created as a by-product of other + operations." + ::= { vlanTrunkPortEntry 6 } + +vlanTrunkPortInJoins OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of VTP Join messages received on this trunk + port." + ::= { vlanTrunkPortEntry 7 } + +vlanTrunkPortOutJoins OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of VTP Join messages sent on this trunk port." + ::= { vlanTrunkPortEntry 8 } + +vlanTrunkPortOldAdverts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of VTP Advertisement messages which indicated + the sender does not support VLAN-pruning received on this + trunk port." + ::= { vlanTrunkPortEntry 9 } + +vlanTrunkPortVlansPruningEligible OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (128)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN in the + management domain on this trunk port. The first octet + corresponds to VLANs with VlanIndex values of 0 through 7; + the second octet to VLANs 8 through 15; etc. The most + significant bit of each octet corresponds to the lowest + value VlanIndex in that octet. + + If the bit corresponding to a VLAN is set to '1', then the + local system is permitted to prune that VLAN on this trunk + port; if the bit is set to '0', then the system must not + prune that VLAN on this trunk port. + + To avoid conflicts between overlapping partial updates by + multiple managers, i.e., updates which modify only a portion + of an instance of this object (e.g., enable/disable a single + VLAN on the trunk port), any SNMP Set operation accessing an + instance of this object should also write the value of + vlanTrunkPortSetSerialNo." + ::= { vlanTrunkPortEntry 10 } + +vlanTrunkPortVlansXmitJoined OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (128)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN in the + management domain on this trunk port. The first octet + corresponds to VLANs with VlanIndex values of 0 through 7; + the second octet to VLANs 8 through 15; etc. The most + significant bit of each octet corresponds to the lowest + value VlanIndex in that octet. + + If the bit corresponding to a VLAN is set to '1', then this + VLAN is presently being forwarded on this trunk port, i.e., + it is not pruned; if the bit is set to '0', then this VLAN + is presently not being forwarded on this trunk port, either + because it is pruned or for some other reason." + ::= { vlanTrunkPortEntry 11 } + +vlanTrunkPortVlansRcvJoined OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (128)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN in the + management domain on this trunk port. The first octet + corresponds to VLANs with VlanIndex values of 0 through 7; + the second octet to VLANs 8 through 15; etc. The most + significant bit of each octet corresponds to the lowest + value VlanIndex in that octet. + + If the bit corresponding to a VLAN is set to '1', then the + local switch is currently sending joins for this VLAN on + this trunk port, i.e., it is asking to receive frames for + this VLAN; if the bit is set to '0', then the local switch + is not currently sending joins for this VLAN on this trunk + port." + ::= { vlanTrunkPortEntry 12 } + +vlanTrunkPortDynamicState OBJECT-TYPE + SYNTAX INTEGER { + on(1), + off(2), + desirable(3), + auto(4), + onNoNegotiate(5) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "For devices that allows dynamic determination of whether + a link between two switches should be a trunk or not, this + object allows the operator to mandate the behavior of that + dynamic mechanism. + + on(1) dictates that the interface will always be a + trunk. This is the value for static entries (those that + show no dynamic behavior). If the negotiation is supported + on this port, negotiation will take place with the far end + to attempt to bring the far end into trunking state. + + off(2) allows an operator to specify that the specified + interface is never to be trunk, regardless of any dynamic + mechanisms to the contrary. This value is useful for + overriding the default behavior of some switches. If the + negotiation is supported on this port, negotiation will take + place with the far end to attempt on the link to bring the + far end into non-trunking state. + + desirable(3) is used to indicate that it is desirable for + the interface to become a trunk. The device will initiate + any negotiation necessary to become a trunk but will not + become a trunk unless it receives confirmation from the far + end on the link. + + auto(4) is used to indicate that the interface is capable + and willing to become a trunk but will not initiate + trunking negotiations. The far end on the link are + required to either start negotiations or start sending + encapsulated packets, on which event the specified + interface will become a trunk. + + onNoNegotiate(5) is used to indicate that the interface is + permanently set to be a trunk, and no negotiation takes + place with the far end on the link to ensure consistent + operation. This is similar to on(1) except no negotiation + takes place with the far end. + + If the port does not support negotiation or its + vlanTrunkPortEncapsulationType is set to negotiate(5), + onNoNegotiate(5) is not allowed. + + Devices that do no support dynamic determination (for just + a particular interface, encapsulation or for the whole + device) need only support the 'on', and 'off' values." + ::= { vlanTrunkPortEntry 13 } + +vlanTrunkPortDynamicStatus OBJECT-TYPE + SYNTAX INTEGER { + trunking(1), + notTrunking(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates whether the specified interface is either + acting as a trunk or not. This is a result of the + vlanTrunkPortDynamicState and the ifOperStatus of the + trunk port itself." + ::= { vlanTrunkPortEntry 14 } + +vlanTrunkPortVtpEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Some trunk interface modules allow VTP to be + enabled/disabled seperately from that of the central + device. In such a case this object provides management a + way to remotely enable VTP on that module. If a module + does not support a seperate VTP enabled state then this + object shall always return 'true' and will accept no other + value during a SET operation." + ::= { vlanTrunkPortEntry 15 } + +vlanTrunkPortEncapsulationOperType OBJECT-TYPE + SYNTAX INTEGER { + isl(1), + dot10(2), + lane(3), + dot1Q(4), + negotiating(5), + notApplicable(6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of VLAN encapsulation in use on this trunk port. + For intefaces with vlanTrunkPortDynamicStatus of + notTrunking(2) the vlanTrunkPortEncapsulationOperType shall + be notApplicable(6)." + ::= { vlanTrunkPortEntry 16 } + +vlanTrunkPortVlansEnabled2k OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..128)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN for VLANS + with VlanIndex values of 1024 through 2047 in the management + domain on this trunk port. The first octet corresponds to + VLANs with VlanIndex values of 1024 through 1031; the second + octet to VLANs 1032 through 1039; etc. The most significant + bit of each octet corresponds to the lowest value VlanIndex + in that octet. If the bit corresponding to a VLAN is set to + '1', then the local system is enabled for sending and + receiving frames on that VLAN; if the bit is set to '0', + then the system is disabled from sending and receiving + frames on that VLAN. The default value is zero length + string. + + To avoid conflicts between overlapping partial updates by + multiple managers, i.e., updates which modify only a portion + of an instance of this object (e.g., enable/disable a single + VLAN on the trunk port), any SNMP Set operation accessing an + instance of this object should also write the value of + vlanTrunkPortSetSerialNo." + ::= { vlanTrunkPortEntry 17 } + +vlanTrunkPortVlansEnabled3k OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..128)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN for VLANS + with VlanIndex values of 2048 through 3071 in the management + domain on this trunk port. The first octet corresponds to + VLANs with VlanIndex values of 2048 through 2055; the second + octet to VLANs 2056 through 2063; etc. The most significant + bit of each octet corresponds to the lowest value VlanIndex + in that octet. If the bit corresponding to a VLAN is set to + '1', then the local system is enabled for sending and + receiving frames on that VLAN; if the bit is set to '0', + then the system is disabled from sending and receiving + frames on that VLAN. The default value is zero length + string. + + To avoid conflicts between overlapping partial updates by + multiple managers, i.e., updates which modify only a portion + of an instance of this object (e.g., enable/disable a single + VLAN on the trunk port), any SNMP Set operation accessing an + instance of this object should also write the value of + vlanTrunkPortSetSerialNo." + ::= { vlanTrunkPortEntry 18 } + +vlanTrunkPortVlansEnabled4k OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..128)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN for VLANS + with VlanIndex values of 3072 through 4095 in the management + domain on this trunk port. The first octet corresponds to + VLANs with VlanIndex values of 3072 through 3079; the second + octet to VLANs 3080 through 3087; etc. The most significant + bit of each octet corresponds to the lowest value VlanIndex + in that octet. If the bit corresponding to a VLAN is set to + '1', then the local system is enabled for sending and + receiving frames on that VLAN; if the bit is set to '0', + then the system is disabled from sending and receiving + frames on that VLAN. The default value is zero length + string. + + To avoid conflicts between overlapping partial updates by + multiple managers, i.e., updates which modify only a portion + of an instance of this object (e.g., enable/disable a single + VLAN on the trunk port), any SNMP Set operation accessing an + instance of this object should also write the value of + vlanTrunkPortSetSerialNo." + ::= { vlanTrunkPortEntry 19 } + +vtpVlansPruningEligible2k OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..128)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN for VLANS + with VlanIndex values of 1024 through 2047 in the management + domain on this trunk port. The first octet corresponds to + VLANs with VlanIndex values of 1024 through 1031; the second + octet to VLANs 1032 through 1039; etc. The most significant + bit of each octet corresponds to the lowest value VlanIndex + in that octet. + + If the bit corresponding to a VLAN is set to '1', then the + local system is permitted to prune that VLAN on this trunk + port; if the bit is set to '0', then the system must not + prune that VLAN on this trunk port. + The default value is zero length string. + + To avoid conflicts between overlapping partial updates by + multiple managers, i.e., updates which modify only a portion + of an instance of this object (e.g., enable/disable a single + VLAN on the trunk port), any SNMP Set operation accessing an + instance of this object should also write the value of + vlanTrunkPortSetSerialNo." + ::= { vlanTrunkPortEntry 20 } + +vtpVlansPruningEligible3k OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..128)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN for VLANS + with VlanIndex values of 2048 through 3071 in the management + domain on this trunk port. The first octet corresponds to + VLANs with VlanIndex values of 2048 through 2055; the second + octet to VLANs 2056 through 2063; etc. The most significant + bit of each octet corresponds to the lowest value VlanIndex + in that octet. + + If the bit corresponding to a VLAN is set to '1', then the + local system is permitted to prune that VLAN on this trunk + port; if the bit is set to '0', then the system must not + prune that VLAN on this trunk port. + The default value is zero length string. + + To avoid conflicts between overlapping partial updates by + multiple managers, i.e., updates which modify only a portion + of an instance of this object (e.g., enable/disable a single + VLAN on the trunk port), any SNMP Set operation accessing an + instance of this object should also write the value of + vlanTrunkPortSetSerialNo." + ::= { vlanTrunkPortEntry 21 } + +vtpVlansPruningEligible4k OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..128)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN for VLANS + with VlanIndex values of 3072 through 4095 in the management + domain on this trunk port. The first octet corresponds to + VLANs with VlanIndex values of 3072 through 3079; the second + octet to VLANs 3080 through 3087; etc. The most significant + bit of each octet corresponds to the lowest value VlanIndex + in that octet. + + If the bit corresponding to a VLAN is set to '1', then the + local system is permitted to prune that VLAN on this trunk + port; if the bit is set to '0', then the system must not + prune that VLAN on this trunk port. + The default value is zero length string. + + To avoid conflicts between overlapping partial updates by + multiple managers, i.e., updates which modify only a portion + of an instance of this object (e.g., enable/disable a single + VLAN on the trunk port), any SNMP Set operation accessing an + instance of this object should also write the value of + vlanTrunkPortSetSerialNo." + ::= { vlanTrunkPortEntry 22 } + +vlanTrunkPortVlansXmitJoined2k OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..128)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN for VLANS + with VlanIndex values of 1024 through 2047 in the management + domain on this trunk port. The first octet corresponds to + VLANs with VlanIndex values of 1024 through 1031; the second + octet to VLANs 1032 through 1039; etc. The most significant + bit of each octet corresponds to the lowest value VlanIndex + in that octet. + + If the bit corresponding to a VLAN is set to '1', then this + VLAN is presently being forwarded on this trunk port, i.e., + it is not pruned; if the bit is set to '0', then this VLAN + is presently not being forwarded on this trunk port, either + because it is pruned or for some other reason." + ::= { vlanTrunkPortEntry 23 } + +vlanTrunkPortVlansXmitJoined3k OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..128)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN for VLANS + with VlanIndex values of 2048 through 3071 in the management + domain on this trunk port. The first octet corresponds to + VLANs with VlanIndex values of 2048 through 2055; the second + octet to VLANs 2056 through 2063; etc. The most significant + bit of each octet corresponds to the lowest value VlanIndex + in that octet. + + If the bit corresponding to a VLAN is set to '1', then this + VLAN is presently being forwarded on this trunk port, i.e., + it is not pruned; if the bit is set to '0', then this VLAN + is presently not being forwarded on this trunk port, either + because it is pruned or for some other reason." + ::= { vlanTrunkPortEntry 24 } + +vlanTrunkPortVlansXmitJoined4k OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..128)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN for VLANS + with VlanIndex values of 3072 through 4095 in the management + domain on this trunk port. The first octet corresponds to + VLANs with VlanIndex values of 3072 through 3079; the second + octet to VLANs 3080 through 3087; etc. The most significant + bit of each octet corresponds to the lowest value VlanIndex + in that octet. + + If the bit corresponding to a VLAN is set to '1', then this + VLAN is presently being forwarded on this trunk port, i.e., + it is not pruned; if the bit is set to '0', then this VLAN + is presently not being forwarded on this trunk port, either + because it is pruned or for some other reason." + ::= { vlanTrunkPortEntry 25 } + +vlanTrunkPortVlansRcvJoined2k OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..128)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN for VLANS + with VlanIndex values of 1024 through 2047 in the management + domain on this trunk port. The first octet corresponds to + VLANs with VlanIndex values of 1024 through 1031; the second + octet to VLANs 1032 through 1039; etc. The most significant + bit of each octet corresponds to the lowest value VlanIndex + in that octet. + + If the bit corresponding to a VLAN is set to '1', then the + local switch is currently sending joins for this VLAN on + this trunk port, i.e., it is asking to receive frames for + this VLAN; if the bit is set to '0', then the local switch + is not currently sending joins for this VLAN on this trunk + port." + ::= { vlanTrunkPortEntry 26 } + +vlanTrunkPortVlansRcvJoined3k OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..128)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN for VLANS + with VlanIndex values of 2048 through 3071 in the management + domain on this trunk port. The first octet corresponds to + VLANs with VlanIndex values of 2048 through 2055; the second + octet to VLANs 2056 through 2063; etc. The most significant + bit of each octet corresponds to the lowest value VlanIndex + in that octet. + + If the bit corresponding to a VLAN is set to '1', then the + local switch is currently sending joins for this VLAN on + this trunk port, i.e., it is asking to receive frames for + this VLAN; if the bit is set to '0', then the local switch + is not currently sending joins for this VLAN on this trunk + port." + ::= { vlanTrunkPortEntry 27 } + +vlanTrunkPortVlansRcvJoined4k OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..128)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN for VLANS + with VlanIndex values of 3072 through 4095 in the management + domain on this trunk port. The first octet corresponds to + VLANs with VlanIndex values of 3072 through 3079; the second + octet to VLANs 3080 through 3087; etc. The most significant + bit of each octet corresponds to the lowest value VlanIndex + in that octet. + + If the bit corresponding to a VLAN is set to '1', then the + local switch is currently sending joins for this VLAN on + this trunk port, i.e., it is asking to receive frames for + this VLAN; if the bit is set to '0', then the local switch + is not currently sending joins for this VLAN on this trunk + port." + ::= { vlanTrunkPortEntry 28 } + +vlanTrunkPortDot1qTunnel OBJECT-TYPE + SYNTAX INTEGER { + trunk(1), + access(2), + disabled(3) + } + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "Indicates dot1qtunnel mode of the port. + + If the portDot1qTunnel is set to 'trunk' mode, the port's + vlanTrunkPortDynamicState will be changed to 'onNoNegotiate' + and the vlanTrunkPortEncapsulationType will be set to + 'dot1Q'. These values cannot be changed unless dot1q tunnel + is disabled on this port. + + If the portDot1qTunnel mode is set to 'access' mode, the + port's vlanTrunkPortDynamicState will be set to 'off'.And + the value of vlanTrunkPortDynamicState cannot be changed + unless dot1q tunnel is disabled on this port. 1Q packets + received on this access port will remain. + + Setting the port to dot1q tunnel 'disabled' mode causes the + dot1q tunnel feature to be disabled on this port. This + object can't be set to 'trunk' or 'access' mode, when + vlanTrunkPortsDot1qTag object is set to 'false'. + + This object has been deprecated and is replaced by the + object 'cltcDot1qTunnelMode' in the + CISCO-L2-TUNNEL-CONFIG-MIB" + DEFVAL { disabled } + ::= { vlanTrunkPortEntry 29 } + +vlanTrunkPortVlansActiveFirst2k OBJECT-TYPE + SYNTAX Cisco2KVlanList + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN + with VlanIndex values of 0 through 2047. + + If the bit corresponding to a VLAN is set to 1, + it indicates that vlan is allowed and active in + management domain. + + If the bit corresponding to a VLAN is set to 0, + it indicates that vlan is not allowed or not active + in management domain." + ::= { vlanTrunkPortEntry 30 } + +vlanTrunkPortVlansActiveSecond2k OBJECT-TYPE + SYNTAX Cisco2KVlanList + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A string of octets containing one bit per VLAN + with VlanIndex values of 2048 through 4095. + + If the bit corresponding to a VLAN is set to 1, + it indicates that vlan is allowed and active in + management domain. + + If the bit corresponding to a VLAN is set to 0, + it indicates that vlan is not allowed or not active + in management domain." + ::= { vlanTrunkPortEntry 31 } + + + +vlanTrunkPortSetSerialNo OBJECT-TYPE + SYNTAX TestAndIncr + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "An advisory lock used to allow several cooperating SNMPv2 + managers to coordinate their use of the SNMPv2 set operation + acting upon any instance of vlanTrunkPortVlansEnabled." + ::= { vlanTrunkPorts 2 } + +vlanTrunkPortsDot1qTag OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "An indication of whether the tagging on all VLANs including + native VLAN for all 802.1q trunks is enabled. + + If this object has a value of true(1) then all VLANs + including native VLAN are tagged. If the value is false(2) + then all VLANs excluding native VLAN are tagged. + + This object has been deprecated and is replaced by the + object 'cltcDot1qAllTaggedEnabled' in the + CISCO-L2-TUNNEL-CONFIG-MIB" + DEFVAL { false } + ::= { vlanTrunkPorts 3 } +vtpDiscover OBJECT IDENTIFIER + ::= { vtpMIBObjects 7 } + + +vtpDiscoverTable OBJECT-TYPE + SYNTAX SEQUENCE OF VtpDiscoverEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains information related to the discovery + of the VTP members in the designated management + domain. This table is not instantiated when + managementDomainVersionInUse is version1(1), version2(3) + or none(3)." + ::= { vtpDiscover 1 } + +vtpDiscoverEntry OBJECT-TYPE + SYNTAX VtpDiscoverEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information related to the discovery of the + VTP members in one management domain." + INDEX { managementDomainIndex } + ::= { vtpDiscoverTable 1 } + +VtpDiscoverEntry ::= SEQUENCE { + vtpDiscoverAction INTEGER, + vtpDiscoverStatus INTEGER, + vtpLastDiscoverTime TimeStamp +} + +vtpDiscoverAction OBJECT-TYPE + SYNTAX INTEGER { + discover(1), + noOperation(2), + purgeResult(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "When this object is set to discover(1), all the + entries in vtpDiscoverResultTable for the + corresponding management domain will be removed + and the local device will begin to discover all + VTP members in the management domain. Upon the + successful completion of discovery, the discovered + result will be stored in the vtpDiscoverResultTable. + + If vtpDiscoverStatus is inProgress(1), setting + vtpDiscoverAction to discover(1) will fail. + + When this object is set to purgeResult(3), + all the entries of vtpDiscoverResultTable for + the corresponding management domain will be + removed from vtpDiscoverResultTable. + + When this object is set to noOperation(2), no + action will be taken. When read, this object + always returns noOperation(2)." + ::= { vtpDiscoverEntry 1 } + +vtpDiscoverStatus OBJECT-TYPE + SYNTAX INTEGER { + inProgress(1), + succeeded(2), + resourceUnavailable(3), + someOtherError(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current status of VTP discovery. + + inProgress - a discovery is in progress; + + succeeded - the discovery was completed successfully + (this value is also used when + no discover has been invoked since the + last time the local system restarted); + + resourceUnavailable - the discovery failed because + the required allocation of a resource is + presently unavailable. + + someOtherError - 'the discovery failed due to a + reason no listed." + ::= { vtpDiscoverEntry 2 } + +vtpLastDiscoverTime OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime at which the last discovery + was completed. + + A value of zero indicates that no discovery has been + invoked since last time the local system restarted." + ::= { vtpDiscoverEntry 3 } + + + +vtpDiscoverResultTable OBJECT-TYPE + SYNTAX SEQUENCE OF VtpDiscoverResultEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table containing information of discovered VTP members + in the management domain in which the local system is + participating. This table is not instantiated when + managementDomainVersionInUse is version1(1), version2(2) or + none(3)." + ::= { vtpDiscover 2 } + +vtpDiscoverResultEntry OBJECT-TYPE + SYNTAX VtpDiscoverResultEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A conceptual row is created for each VTP member which + is found through successful discovery." + INDEX { + managementDomainIndex, + vtpDiscoverResultIndex + } + ::= { vtpDiscoverResultTable 1 } + +VtpDiscoverResultEntry ::= SEQUENCE { + vtpDiscoverResultIndex Unsigned32, + vtpDiscoverResultDatabaseName SnmpAdminString, + vtpDiscoverResultConflicting TruthValue, + vtpDiscoverResultDeviceId SnmpAdminString, + vtpDiscoverResultPrimaryServer SnmpAdminString, + vtpDiscoverResultRevNumber Gauge32, + vtpDiscoverResultSystemName SnmpAdminString +} + +vtpDiscoverResultIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A value assigned by the system which identifies + a VTP member and the associated database in the + management domain." + ::= { vtpDiscoverResultEntry 1 } + +vtpDiscoverResultDatabaseName OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The database name associated with the + discovered VTP member." + ::= { vtpDiscoverResultEntry 2 } + +vtpDiscoverResultConflicting OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates whether this VTP member contains + conflicting information. + + true(1) indicates that this member has conflicting + information of the database type in the management domain. + + false(2) indicates that there is no conflicting information + of the database type in the management domain." + ::= { vtpDiscoverResultEntry 3 } + +vtpDiscoverResultDeviceId OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique identifier of the device for this VTP member." + ::= { vtpDiscoverResultEntry 4 } + +vtpDiscoverResultPrimaryServer OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique identifier of the primary server for this VTP + member and the associated database type. + + There are two different VTP servers, the primary server + and the secondary server. When a local device is + configured as a server for a certain database type, + it becomes secondary server by default. + Primary server is an operational role under which a + server can initiate or change the VTP configuration of the + database type. + + If this VTP member itself is the primary server, the + value of this object is the same as the value of + vtpDiscoverResultDeviceId of the instance." + ::= { vtpDiscoverResultEntry 5 } + +vtpDiscoverResultRevNumber OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current configuration revision number as known by the + VTP member. When the database type is unknown for + the VTP member, this value is 0." + ::= { vtpDiscoverResultEntry 6 } + +vtpDiscoverResultSystemName OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "sysName of the VTP member." + ::= { vtpDiscoverResultEntry 7 } + + +vtpDatabase OBJECT IDENTIFIER + ::= { vtpMIBObjects 8 } + + +vtpDatabaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF VtpDatabaseEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains information of the VTP + databases. It is not instantiated when + managementDomainVersionInUse is version1(1), + version2(3) or none(3)." + ::= { vtpDatabase 1 } + +vtpDatabaseEntry OBJECT-TYPE + SYNTAX VtpDatabaseEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information about the status of the VTP database + in the domain. Each VTP database type known to the + local device type has an entry in this table. + An entry is also created for unknown database which is + notified through VTP advertisements from other VTP + servers." + INDEX { + managementDomainIndex, + vtpDatabaseIndex + } + ::= { vtpDatabaseTable 1 } + +VtpDatabaseEntry ::= SEQUENCE { + vtpDatabaseIndex Unsigned32, + vtpDatabaseName SnmpAdminString, + vtpDatabaseLocalMode INTEGER, + vtpDatabaseRevNumber Gauge32, + vtpDatabasePrimaryServer TruthValue, + vtpDatabasePrimaryServerId SnmpAdminString, + vtpDatabaseTakeOverPrimary TruthValue, + vtpDatabaseTakeOverPassword SnmpAdminString +} + +vtpDatabaseIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A value assigned by the system which uniquely identifies + a VTP database in the local system." + ::= { vtpDatabaseEntry 1 } + +vtpDatabaseName OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the database." + ::= { vtpDatabaseEntry 2 } + +vtpDatabaseLocalMode OBJECT-TYPE + SYNTAX INTEGER { + client(1), + server(2), + transparent(3), + off(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The local VTP mode for a particular database type + in this administrative domain. + + - 'client' indicates that the local system is acting + as a VTP client of the database type. + + - 'server' indicates that the local system is acting + as a VTP server of the database type. + + - 'transparent' indicates that the local system does + not generate or listen to VTP messages of this + database type, but forwards + messages. This mode can also be set by the device + itself when the size of database is too large for it + to hold in DRAM. + + - 'off' indicates that the local system does not + generate, listen to or forward any VTP messages + of this database type. + + The default mode is 'client' for the database type + known to the local device and 'transparent' for the + unknown database type." + ::= { vtpDatabaseEntry 3 } + +vtpDatabaseRevNumber OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current configuration revision number as known by the + local device for this VTP 3 database type in the management + domain. This value is updated (if necessary) whenever a + VTP advertisement for the database type is received + or generated. When the database type is unknown to the + local device or no VTP advertisement for the database + type is received or generated, its value is 0." + ::= { vtpDatabaseEntry 4 } + +vtpDatabasePrimaryServer OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "There are two kinds of VTP version 3 servers for a certain + database type - the primary server and the secondary server. + When a local device is configured as a server for a certain + database type, it becomes secondary server by default. + Primary server is an operational role under which a + server can initiate or change the VTP configuration of the + database type. + + A true(1) value indicates that the local device is the + primary server of the database type in the management + domain. A false(2) value indicates that the local device + is not the primary server, or the database type is unknown + to the local device." + ::= { vtpDatabaseEntry 5 } + +vtpDatabasePrimaryServerId OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique identifier of the primary server in the + management domain for the database type. + + If no primary server is discovered for the database + type, the object has a value of zero length string." + ::= { vtpDatabaseEntry 6 } + +vtpDatabaseTakeOverPrimary OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "There are two kinds of VTP version 3 servers for a certain + database type - the primary server and the secondary server. + When a local device is configured as a server for a certain + database type, it becomes secondary server by default. + Primary server is an operational role under which a + server can initiate or change the VTP configuration of the + database type. + + Setting this object to a true(1) value will advertise the + configuration of this database type to the whole domain. + + In order to successfully setting this object to true(1), + the value of vtpDatabaseLocalMode must be server(2). Besides + that, when the VTP password is hidden from the configuration + file, the password (vtpDatabaseTakeOverPassword) which + matches the secret key (vtpAuthSecretKey) must be provided + in the same data packet. + + When read, the object always returns false(2)." + ::= { vtpDatabaseEntry 7 } + +vtpDatabaseTakeOverPassword OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..64)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "When read, this object always returns the value of a + zero-length octet string. + + In the case that the VTP password is hidden from the + configuration and the local device intends + to take over the whole domain, this object must be + set to the matching password with the secret key + (vtpAuthSecretKey) in the same data packet as which + the vtpDatabaseTakeOverPrimary is in. In all the + other situations, setting a valid value to this object + has no impact on the system." + ::= { vtpDatabaseEntry 8 } + + +vtpAuthentication OBJECT IDENTIFIER + ::= { vtpMIBObjects 9 } + + +vtpAuthenticationTable OBJECT-TYPE + SYNTAX SEQUENCE OF VtpAuthEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table contains the authentication information of VTP + in which the local system participates. + + The security mechanism of VTP relies on a secret key + that is used to alter the MD5 digest of the packets + transmitted on the wire. The secret value is + created from a password that may be saved in plain text + in the configuration or hidden from the configuration. + + The device creating or modifying the VTP configuration + signs it using the MD5 digest generated from the secret + key before advertising it. Other devices in the domain + receive this configuration use the same secret key + to accept it if correctly signed or drop it otherwise. + + The user has the option to hide the password from the + configuration. Once the password is hidden, the secret + key generated from the password is shown in the + configuration instead, and there is no other way to + show the password in plain text again but clearing + it or resetting it. + + In an un-trusted area, the password on a device can + be configured without being unveiled. After that, + it has to be provided again by setting the same + value to vtpDatabaseTakeOverPassword if the user + wants to take over the whole VTP management domain + of the database type. + + When managementDomainVersionInUse is version3(4), the + authentication mechanism is common to all VTP + database type." + ::= { vtpAuthentication 1 } + +vtpAuthEntry OBJECT-TYPE + SYNTAX VtpAuthEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information about the status of the VTP + authentication information in one domain." + INDEX { managementDomainIndex } + ::= { vtpAuthenticationTable 1 } + +VtpAuthEntry ::= SEQUENCE { + vtpAuthPassword SnmpAdminString, + vtpAuthPasswordType INTEGER, + vtpAuthSecretKey OCTET STRING +} + +vtpAuthPassword OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..64)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "By default, this object has a value of a zero-length + character string and is considered to be not + configured. + + The device uses the password to generate the + secret key. It can be stored in the configuration in + plain text or hidden from the configuration. If a VTP + server intends to modify the database's configuration + in the domain but the password was hidden from the + configuration, the same password + (vtpDatabaseTakeOverPassword) as the hidden one + has to be provided. + + When this object is set alone, vtpAuthPasswordType is + set to plaintext(1) automatically by the system. + Setting this object to a zero length character string + resets the password to its default value and the + password is considered as not configured. + + This object is not allowed to be set at the same time + when vtpAuthSecretKey is set. + + When the vtpAuthPasswordType is hidden(2), this object + will return a zero-length character string when read." + ::= { vtpAuthEntry 1 } + +vtpAuthPasswordType OBJECT-TYPE + SYNTAX INTEGER { + plaintext(1), + hidden(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "By default this object has the value as plaintext(1) + and the VTP password is stored in the configuration + file in plain text. + + Setting this object to hidden(2) will hide the + password from the configuration. + + Once this object is set to hidden(2), it cannot + be set to plaintext(1) alone. However, it may + be set to plaintext(1) at the same time the + password is set." + ::= { vtpAuthEntry 2 } + +vtpAuthSecretKey OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0 | 16)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The device creating or modifying the VTP configuration + signs it using the MD5 digest generated from the secret + key before advertising it. Other devices in the domain + receiving this configuration use the same secret key + to accept it if it was correctly signed or drop it + otherwise. + + By default, the object has the value as a zero-length + string and this value is read only. It is set + to this value automatically when the password + (vtpAuthPassword) is set to a zero-length octet string. + + The secret key can be either generated using + the password or configured by the user. Once + the secret key is configured by the user, it is + stored as a hexadecimal string in the device's + configuration and the password is considered to be + the secret key's matching password and hidden + from the configuration automatically. + + This object is not allowed to be set at the same + time when vtpAuthPassword is set. + + The secret key is overwritten by a newly generated + secret key when the password is re-configured." + ::= { vtpAuthEntry 3 } + + +vlanStatistics OBJECT IDENTIFIER + ::= { vtpMIBObjects 10 } + + +vlanStatsVlans OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the number of the existing + manageable VLANs with VLAN indices from 1 to + 1024 in the system." + ::= { vlanStatistics 1 } + +vlanStatsExtendedVlans OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the number of the + existing manageable VLANs with VLAN indices + greater than 1024 in the system." + ::= { vlanStatistics 2 } + +vlanStatsInternalVlans OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the number of the + internal VLANs existing in the system." + ::= { vlanStatistics 3 } + +vlanStatsFreeVlans OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the number of the + free or unused VLANs in the system." + ::= { vlanStatistics 4 } +-- VTP notifications + +vtpNotifications OBJECT IDENTIFIER + ::= { ciscoVtpMIB 2 } + +vtpNotificationsPrefix OBJECT IDENTIFIER + ::= { vtpNotifications 0 } + +vtpNotificationsObjects OBJECT IDENTIFIER + ::= { vtpNotifications 1 } + + +vtpConfigRevNumberError NOTIFICATION-TYPE + OBJECTS { managementDomainConfigRevNumber } + STATUS current + DESCRIPTION + "A configuration revision number error notification + signifies that a device has incremented its + vtpConfigRevNumberErrors counter. + + Generation of this notification is suppressed if the + vtpNotificationsEnabled has the value 'false'. + + The device must throttle the generation of consecutive + vtpConfigRevNumberError notifications so that there is at + least a five-second gap between notification of this type. + When notification are throttled, they are dropped, not + queued for sending at a future time. (Note that + 'generating' a notification means sending to all configured + recipients.)" + ::= { vtpNotificationsPrefix 1 } + +vtpConfigDigestError NOTIFICATION-TYPE + OBJECTS { managementDomainConfigRevNumber } + STATUS current + DESCRIPTION + "A configuration digest error notification signifies that a + device has incremented its vtpConfigDigestErrors counter. + + Generation of this notification is suppressed if the + vtpNotificationsEnabled has the value 'false'. + + The device must throttle the generation of consecutive + vtpConfigDigestError notifications so that there is at least + a five-second gap between notification of this type. When + notification are throttled, they are dropped, not queued for + sending at a future time. (Note that 'generating' a + notification means sending to all configured recipients.)" + ::= { vtpNotificationsPrefix 2 } + +vtpServerDisabled NOTIFICATION-TYPE + OBJECTS { + managementDomainConfigRevNumber, + vtpMaxVlanStorage + } + STATUS current + DESCRIPTION + "A VTP Server disabled notification is generated when the + local system is no longer able to function as a VTP Server + because the number of defined VLANs is greater than + vtpMaxVlanStorage or the local system is not able to + recover complete VTP information after a reboot. + + Generation of this notification is suppressed if the + vtpNotificationsEnabled has the value 'false'." + ::= { vtpNotificationsPrefix 3 } + +vtpMtuTooBig NOTIFICATION-TYPE + OBJECTS { + vlanTrunkPortManagementDomain, + vtpVlanState + } + STATUS current + DESCRIPTION + "A VTP MTU tooBig notification is generated when a VLAN's + MTU size is larger than can be supported either: + + - by one or more of its trunk ports: + the included vtpVlanState has the value + 'mtuTooBigForTrunk' and the included + vlanTrunkPortManagementDomain is for the first (or only) + trunk port, + or + + - by the device itself: + vtpVlanState has the value 'mtuTooBigForDevice' and any + instance of vlanTrunkPortManagementDomain is included. + + Devices which have no trunk ports do not send vtpMtuTooBig + notifications. + + Generation of this notification is suppressed if the + vtpNotificationsEnabled has the value 'false'." + ::= { vtpNotificationsPrefix 4 } + +vtpVersionOneDeviceDetected NOTIFICATION-TYPE + OBJECTS { vlanTrunkPortManagementDomain } + STATUS current + DESCRIPTION + "A VTP version one device detected notification is + generated by a device when: + + a) a management domain has been put into version 2 mode + (as accessed by managementDomainVersionInUse). + b) 15 minutes has passed since a). + c) a version 1 PDU is detected on a trunk on the device + that is in that management domain which has a lower + revision number than the current configuration." + ::= { vtpNotificationsPrefix 6 } + +vlanTrunkPortDynamicStatusChange NOTIFICATION-TYPE + OBJECTS { vlanTrunkPortDynamicStatus } + STATUS current + DESCRIPTION + "A vlanTrunkPortDynamicStatusChange notification is + generated by a device when the value of + vlanTrunkPortDynamicStatus object has been changed." + ::= { vtpNotificationsPrefix 7 } + +vtpLocalModeChanged NOTIFICATION-TYPE + OBJECTS { managementDomainLocalMode } + STATUS current + DESCRIPTION + "A vtpLocalModeChanged notification is generated + by a device when the value of the object + managementDomainLocalMode is changed." + ::= { vtpNotificationsPrefix 8 } + +vtpVersionInUseChanged NOTIFICATION-TYPE + OBJECTS { managementDomainVersionInUse } + STATUS current + DESCRIPTION + "A vtpVersionInUseChanged notification is + generated by a device when the value of the + object managementDomainVersionInUse is + changed." + ::= { vtpNotificationsPrefix 9 } + +vtpVlanCreated NOTIFICATION-TYPE + OBJECTS { vtpVlanName } + STATUS current + DESCRIPTION + "A vtpVlanCreated notification is generated by a + device when a VLAN is created." + ::= { vtpNotificationsPrefix 10 } + +vtpVlanDeleted NOTIFICATION-TYPE + OBJECTS { vtpVlanName } + STATUS current + DESCRIPTION + "A vtpVlanDeleted notification is generated by a + device when a VLAN is deleted." + ::= { vtpNotificationsPrefix 11 } + +vtpVlanRingNumberConflict NOTIFICATION-TYPE + OBJECTS { + vtpVlanRingNumber, + ifIndex, + vtpVlanPortLocalSegment + } + STATUS current + DESCRIPTION + "A VTP ring number configuration conflict notification is + generated if, and only at the time when, a device learns of + a conflict between: + + a) the ring number (vtpVlanPortLocalSegment) being used on a + token ring segment attached to the port identified by + ifIndex, and + + b) the VTP-obtained ring number (vtpVlanRingNumber) for the + VLAN identified by vtpVlanIndex. + + When such a conflict occurs, the bridge port is put into an + administrative down position until the conflict is resolved + through local/network management intervention. + + This notification is only applicable to VLANs of type + 'tokenRing'." + ::= { vtpNotificationsPrefix 12 } + +vtpPruningStateOperChange NOTIFICATION-TYPE + OBJECTS { managementDomainPruningStateOper } + STATUS current + DESCRIPTION + "A vtpPruningStateOperChange notification is generated + by the device when the instance value of + managementDomainPruningStateOper is changed." + ::= { vtpNotificationsPrefix 13 } + +vtpVlanPortLocalSegment OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The ring (segment) number in use on a 802.5 ring. For + bridges supporting RFC 1525, this value is the same as given + by dot1dSrPortLocalSegment for the bridge port attached to + that ring. When tokenRing VLANs are in use, each 'trNet' + VLAN can/does have a different instance of + dot1dSrPortLocalSegment for each physical port. Note that + access to the particuler instance of dot1dSrPortLocalSegment + requires knowledge of how the agent supports the multiple + 'contexts' required to implement RFC 1525 for multiple + VLANs; also note that the assignment of ifIndex values may + be different in different 'contexts'." + ::= { vtpNotificationsObjects 1 } +-- Conformance Information + +vtpMIBConformance OBJECT IDENTIFIER + ::= { ciscoVtpMIB 3 } + +vtpMIBCompliances OBJECT IDENTIFIER + ::= { vtpMIBConformance 1 } + +vtpMIBGroups OBJECT IDENTIFIER + ::= { vtpMIBConformance 2 } + + +-- compliance statements + +vtpMIBCompliance MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpStatsGroup, + vtpTrunkPortGroup + } + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + OBJECT managementDomainRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { vtpMIBCompliances 1 } + +vtpMIBCompliance2 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpStatsGroup, + vtpTrunkPortGroup + } + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + GROUP vtp4kVlanGroup + DESCRIPTION + "This group must be implemented by the VTP Servers + which support the range of VlanIndex between 1024 + and 4095." + + OBJECT managementDomainRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { vtpMIBCompliances 2 } + +vtpMIBCompliance3 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpStatsGroup, + vtpTrunkPortGroup + } + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + GROUP vtp4kVlanGroup + DESCRIPTION + "This group must be implemented by the VTP Servers + which support the range of VlanIndex between 1024 + and 4095." + + GROUP vtpDot1qTunnelGroup + DESCRIPTION + "This group is mandatory for all the ports which + implement dot1qtunnel feature." + + OBJECT managementDomainRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortDot1qTunnel + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only for interface which doesn't + support dot1q tunnel feature." + ::= { vtpMIBCompliances 3 } + +vtpMIBCompliance4 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpStatsGroup, + vtpTrunkPortGroup + } + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + GROUP vtp4kVlanGroup + DESCRIPTION + "This group must be implemented by the VTP Servers + which support the range of VlanIndex between 1024 + and 4095." + + GROUP vtpDot1qTunnelGroup + DESCRIPTION + "This group is mandatory for all the ports which + implement dot1qtunnel feature." + + GROUP vtpVlanIfIndexGroup + DESCRIPTION + "This group is an optional group containing + objects providing information about the mapping + of VLAN ID to its corresponding IfIndex." + + OBJECT managementDomainRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortDot1qTunnel + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only for interface which doesn't + support dot1q tunnel feature." + ::= { vtpMIBCompliances 4 } + +vtpMIBCompliance5 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpStatsGroup, + vtpTrunkPortGroup, + vtpVersion2BasicGroup + } + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + GROUP vtp4kVlanGroup + DESCRIPTION + "This group must be implemented by the VTP Servers + which support the range of VlanIndex between 1024 + and 4095." + + GROUP vtpDot1qTunnelGroup + DESCRIPTION + "This group is mandatory for all the ports which + implement dot1qtunnel feature." + + GROUP vtpVlanIfIndexGroup + DESCRIPTION + "This group is an optional group containing + objects providing information about the mapping + of VLAN ID to its corresponding IfIndex." + + GROUP vtpVlanInfoEditGroup2 + DESCRIPTION + "This group is mandatory for devices which only support + one VLAN editing for each 'apply' operation." + + OBJECT managementDomainRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT managementDomainName + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainLocalMode + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainTftpServer + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainTftpPathname + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainVersionInUse + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortDot1qTunnel + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only for interface which doesn't + support dot1q tunnel feature." + ::= { vtpMIBCompliances 5 } + +vtpMIBCompliance6 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpConfigNotificationsGroup, + vtpStatsGroup, + vtpTrunkPortGroup, + vtpVersion2BasicGroup, + vtpNotificationObjectsGroup + } + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + GROUP vtp4kVlanGroupRev1 + DESCRIPTION + "This group must be implemented by the VTP Servers + which support the range of VlanIndex between 1024 + and 4095." + + GROUP vtpDot1qTunnelGroup + DESCRIPTION + "This group is mandatory for all the ports which + implement dot1qtunnel feature." + + GROUP vtpVlanIfIndexGroup + DESCRIPTION + "This group is an optional group containing + objects providing information about the mapping + of VLAN ID to its corresponding IfIndex." + + GROUP vtpVlanInfoEditGroup2 + DESCRIPTION + "This group is mandatory for devices which only support + one VLAN editing for each 'apply' operation." + + OBJECT managementDomainRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT managementDomainName + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainLocalMode + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainTftpServer + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainTftpPathname + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainVersionInUse + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditTypeExt2 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortDot1qTunnel + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only for interface which doesn't + support dot1q tunnel feature." + ::= { vtpMIBCompliances 6 } + +vtpMIBCompliance7 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpConfigNotificationsGroup, + vtpStatsGroup, + vtpTrunkPortGroup, + vtpVersion2BasicGroup, + vtpNotificationObjectsGroup + } + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + GROUP vtp4kVlanGroupRev1 + DESCRIPTION + "This group must be implemented by the VTP Servers + which support the range of VlanIndex between 1024 + and 4095." + + GROUP vtpDot1qTunnelGroup + DESCRIPTION + "This group is mandatory for all the ports which + implement dot1qtunnel feature." + + GROUP vtpVlanIfIndexGroup + DESCRIPTION + "This group is an optional group containing + objects providing information about the mapping + of VLAN ID to its corresponding IfIndex." + + GROUP vtpVlanInfoEditGroup2 + DESCRIPTION + "This group is mandatory for devices which only support + one VLAN editing for each 'apply' operation." + + OBJECT managementDomainRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT managementDomainName + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainLocalMode + SYNTAX INTEGER { + client(1), + server(2), + transparent(3) + } + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3). Write access for transparent(3) + is not required." + + OBJECT managementDomainTftpServer + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainTftpPathname + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainVersionInUse + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditTypeExt2 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortDot1qTunnel + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only for interface which doesn't + support dot1q tunnel feature." + ::= { vtpMIBCompliances 7 } + +vtpMIBCompliance8 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpConfigNotificationsGroup, + vtpStatsGroup, + vtpTrunkPortGroup, + vtpVersion2BasicGroup, + vtpNotificationObjectsGroup + } + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + GROUP vtp4kVlanGroupRev1 + DESCRIPTION + "This group must be implemented by the VTP Servers + which support the range of VlanIndex between 1024 + and 4095." + + GROUP vtpDot1qTunnelGroup2 + DESCRIPTION + "This group is mandatory for all the ports which + implement dot1qtunnel feature." + + GROUP vtpVlanIfIndexGroup + DESCRIPTION + "This group is an optional group containing + objects providing information about the mapping + of VLAN ID to its corresponding IfIndex." + + GROUP vtpVlanInfoEditGroup2 + DESCRIPTION + "This group is mandatory for devices which only support + one VLAN editing for each 'apply' operation." + + OBJECT managementDomainRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT managementDomainName + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainLocalMode + SYNTAX INTEGER { + client(1), + server(2), + transparent(3) + } + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3). Write access for transparent(3) + is not required." + + OBJECT managementDomainTftpServer + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainTftpPathname + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainVersionInUse + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditTypeExt2 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { vtpMIBCompliances 8 } + +vtpMIBCompliance9 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpConfigNotificationsGroup, + vtpStatsGroup, + vtpTrunkPortGroup, + vtpVersion2BasicGroup, + vtpNotificationObjectsGroup + } + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + GROUP vtp4kVlanGroupRev1 + DESCRIPTION + "This group must be implemented by the VTP Servers + which support the range of VlanIndex between 1024 + and 4095." + + GROUP vtpVlanIfIndexGroup + DESCRIPTION + "This group is an optional group containing + objects providing information about the mapping + of VLAN ID to its corresponding IfIndex." + + GROUP vtpVlanInfoEditGroup2 + DESCRIPTION + "This group is mandatory for devices which only support + one VLAN editing for each 'apply' operation." + + GROUP vtpVlanNotifEnabledGroup + DESCRIPTION + "This group is mandatory for devices which support the + notifications/traps in vtpConfigNotificationsGroup3." + + OBJECT managementDomainRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT managementDomainName + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainLocalMode + SYNTAX INTEGER { + client(1), + server(2), + transparent(3) + } + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3). Write access for transparent(3) + is not required." + + OBJECT managementDomainTftpServer + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainTftpPathname + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainVersionInUse + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditTypeExt2 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { vtpMIBCompliances 9 } + +vtpMIBCompliance10 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpConfigNotificationsGroup, + vtpStatsGroup, + vtpTrunkPortGroup, + vtpVersion2BasicGroup, + vtpNotificationObjectsGroup + } + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + GROUP vtp4kVlanGroupRev1 + DESCRIPTION + "This group must be implemented by the VTP Servers + which support the range of VlanIndex between 1024 + and 4095." + + GROUP vtpVlanIfIndexGroup + DESCRIPTION + "This group is an optional group containing + objects providing information about the mapping + of VLAN ID to its corresponding IfIndex." + + GROUP vtpVlanInfoEditGroup2 + DESCRIPTION + "This group is mandatory for devices which only support + one VLAN editing for each 'apply' operation." + + GROUP vtpVlanNotifEnabledGroup + DESCRIPTION + "This group is mandatory for devices which support the + notifications/traps in vtpConfigNotificationsGroup3." + + GROUP vtpDiscoverGroup + DESCRIPTION + "This group is mandatory for devices which support the + VTP discovery." + + GROUP vtpDatabaseGroup + DESCRIPTION + "This group is mandatory for devices which support the + VTP distribution of different database types." + + GROUP vtpAuthGroup + DESCRIPTION + "This group is mandatory for devices which support + asymmetric keys authentication mechanism for VTP." + + OBJECT managementDomainRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT managementDomainName + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainLocalMode + SYNTAX INTEGER { + client(1), + server(2), + transparent(3) + } + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainTftpServer + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainTftpPathname + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainVersionInUse + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditTypeExt2 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { vtpMIBCompliances 10 } + +vtpMIBCompliance11 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpConfigNotificationsGroupRev1, + vtpStatsGroup, + vtpTrunkPortGroup, + vtpVersion2BasicGroup, + vtpNotificationObjectsGroup + } + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + GROUP vtp4kVlanGroupRev1 + DESCRIPTION + "This group must be implemented by the VTP Servers + which support the range of VlanIndex between 1024 + and 4095." + + GROUP vtpVlanIfIndexGroup + DESCRIPTION + "This group is an optional group containing + objects providing information about the mapping + of VLAN ID to its corresponding IfIndex." + + GROUP vtpVlanInfoEditGroup2 + DESCRIPTION + "This group is mandatory for devices which only support + one VLAN editing for each 'apply' operation." + + GROUP vtpVlanNotifEnabledGroup + DESCRIPTION + "This group is mandatory for devices which support the + notifications/traps in vtpConfigNotificationsGroup3." + + GROUP vtpDiscoverGroup + DESCRIPTION + "This group is mandatory for devices which support the + VTP discovery." + + GROUP vtpDatabaseGroup + DESCRIPTION + "This group is mandatory for devices which support the + VTP distribution of different database types." + + GROUP vtpAuthGroup + DESCRIPTION + "This group is mandatory for devices which support + asymmetric keys authentication mechanism for VTP." + + OBJECT managementDomainRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT managementDomainName + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainLocalMode + SYNTAX INTEGER { + client(1), + server(2), + transparent(3) + } + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainTftpServer + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainTftpPathname + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainVersionInUse + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditTypeExt2 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { vtpMIBCompliances 11 } + +vtpMIBCompliance12 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpConfigNotificationsGroupRev1, + vtpStatsGroup, + vtpTrunkPortGroup, + vtpVersion2BasicGroup, + vtpNotificationObjectsGroup + } + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + GROUP vtp4kVlanGroupRev1 + DESCRIPTION + "This group must be implemented by the VTP Servers + which support the range of VlanIndex between 1024 + and 4095." + + GROUP vtpVlanIfIndexGroup + DESCRIPTION + "This group is an optional group containing + objects providing information about the mapping + of VLAN ID to its corresponding IfIndex." + + GROUP vtpVlanInfoEditGroup2 + DESCRIPTION + "This group is mandatory for devices which only support + one VLAN editing for each 'apply' operation." + + GROUP vtpVlanNotifEnabledGroup + DESCRIPTION + "This group is mandatory for devices which support the + notifications/traps in vtpConfigNotificationsGroup3." + + GROUP vtpDiscoverGroup + DESCRIPTION + "This group is mandatory for devices which support the + VTP discovery." + + GROUP vtpDatabaseGroup + DESCRIPTION + "This group is mandatory for devices which support the + VTP distribution of different database types." + + GROUP vtpAuthGroup + DESCRIPTION + "This group is mandatory for devices which support + asymmetric keys authentication mechanism for VTP." + + GROUP vtpInternalVlanGrp + DESCRIPTION + "Implementation of this group is optional." + + OBJECT managementDomainRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT managementDomainName + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainLocalMode + SYNTAX INTEGER { + client(1), + server(2), + transparent(3) + } + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainTftpServer + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainTftpPathname + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainVersionInUse + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditTypeExt2 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { vtpMIBCompliances 12 } + +vtpMIBCompliance13 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpConfigNotificationsGroupRev1, + vtpStatsGroup, + vtpTrunkPortGroup, + vtpVersion2BasicGroup, + vtpNotificationObjectsGroup + } + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + GROUP vtp4kVlanGroupRev1 + DESCRIPTION + "This group must be implemented by the VTP Servers + which support the range of VlanIndex between 1024 + and 4095." + + GROUP vtpVlanIfIndexGroup + DESCRIPTION + "This group is an optional group containing + objects providing information about the mapping + of VLAN ID to its corresponding IfIndex." + + GROUP vtpVlanInfoEditGroup2 + DESCRIPTION + "This group is mandatory for devices which only support + one VLAN editing for each 'apply' operation." + + GROUP vtpVlanNotifEnabledGroup + DESCRIPTION + "This group is mandatory for devices which support the + notifications/traps in vtpConfigNotificationsGroup3." + + GROUP vtpDiscoverGroup + DESCRIPTION + "This group is mandatory for devices which support the + VTP discovery." + + GROUP vtpDatabaseGroup + DESCRIPTION + "This group is mandatory for devices which support the + VTP distribution of different database types." + + GROUP vtpAuthGroup + DESCRIPTION + "This group is mandatory for devices which support + asymmetric keys authentication mechanism for VTP." + + GROUP vtpInternalVlanGrp + DESCRIPTION + "Implementation of this group is optional." + + GROUP vlanStatsGroup + DESCRIPTION + "This group is mandatory for agents capable of + providing VLAN statistics information." + + GROUP vtpConfigNotificationsGroup6 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpConfigNotificationsGroup7 + DESCRIPTION + "Implementation of this group is optional." + + OBJECT managementDomainRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT vlanTrunkPortRowStatus + SYNTAX INTEGER { + active(1) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and only one + of the six enumerated values for the + RowStatus textual convention need be + supported, specifically: active(1)." + + OBJECT managementDomainName + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainLocalMode + SYNTAX INTEGER { + client(1), + server(2), + transparent(3) + } + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainTftpServer + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainTftpPathname + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT managementDomainVersionInUse + MIN-ACCESS read-only + DESCRIPTION + "This object is read-only if vtpVersion + is none(3)." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditTypeExt2 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { vtpMIBCompliances 13 } + +vtpMIBCompliance14 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpConfigNotificationsGroupRev1, + vtpStatsGroup, + vtpTrunkPortGroup, + vtpVersion2BasicGroup, + vtpNotificationObjectsGroup + } + + GROUP vtpTrunkPruningGroup + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpTrunkPruningGroup2 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpTrunkPortGroup2 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + GROUP vtpTrunkPortGroup3 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtp4kVlanGroupRev1 + DESCRIPTION + "This group must be implemented by the VTP Servers + which support the range of VlanIndex between 1024 + and 4095." + + GROUP vtpVlanIfIndexGroup + DESCRIPTION + "This group is an optional group containing + objects providing information about the mapping + of VLAN ID to its corresponding IfIndex." + + GROUP vtpVlanInfoEditGroup2 + DESCRIPTION + "This group is mandatory for devices which only support + one VLAN editing for each 'apply' operation." + + GROUP vtpVlanNotifEnabledGroup + DESCRIPTION + "This group is mandatory for devices which support the + notifications/traps in vtpConfigNotificationsGroup3." + + GROUP vtpConfigNotificationsGroup2 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpConfigNotificationsGroup3 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpConfigNotificationsGroup4 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpDiscoverGroup + DESCRIPTION + "This group is mandatory for devices which support the + VTP discovery." + + GROUP vtpDatabaseGroup + DESCRIPTION + "This group is mandatory for devices which support the + VTP distribution of different database types." + + GROUP vtpAuthGroup + DESCRIPTION + "This group is mandatory for devices which support + asymmetric keys authentication mechanism for VTP." + + GROUP vtpInternalVlanGrp + DESCRIPTION + "Implementation of this group is optional." + + GROUP vlanStatsGroup + DESCRIPTION + "This group is mandatory for agents capable of + providing VLAN statistics information." + + GROUP vtpConfigNotificationsGroup6 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpConfigNotificationsGroup7 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpTrunkPruningGroup3 + DESCRIPTION + "This group is mandatory for devices which + support operational VTP pruning state." + + GROUP vtpConfigNotificationsGroup8 + DESCRIPTION + "This group is mandatory for devices which + support the notification generation on operational + VTP pruning state change." + + OBJECT vtpNotificationsEnabled + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanCreatedNotifEnabled + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanDeletedNotifEnabled + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainName + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainLocalMode + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainRowStatus + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainTftpServer + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainTftpPathname + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainPruningState + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainVersionInUse + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpInternalVlanAllocPolicy + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditOperation + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditBufferOwner + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditConfigRevNumber + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditState + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditName + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditMtu + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditDot10Said + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditRingNumber + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditBridgeNumber + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditStpType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditParentVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditRowStatus + SYNTAX INTEGER { + active(1) + } + WRITE-SYNTAX INTEGER { + createAndGo(4), + destroy(6) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. + + Support for createAndWait and notInService is not required." + + OBJECT vtpVlanEditTranslationalVlan1 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditTranslationalVlan2 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditBridgeType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditAreHopCount + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditSteHopCount + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditIsCRFBackup + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditTypeExt2 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVlansEnabled + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortRowStatus + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVlansPruningEligible + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortDynamicState + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVtpEnabled + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVlansEnabled2k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVlansEnabled3k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVlansEnabled4k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlansPruningEligible2k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlansPruningEligible3k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlansPruningEligible4k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortSetSerialNo + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpDiscoverAction + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpDatabaseLocalMode + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpDatabaseTakeOverPrimary + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpDatabaseTakeOverPassword + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpAuthPassword + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpAuthPasswordType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpAuthSecretKey + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { vtpMIBCompliances 14 } + +vtpMIBCompliance15 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpConfigNotificationsGroupRev1, + vtpStatsGroup, + vtpTrunkPortGroup, + vtpVersion2BasicGroup, + vtpNotificationObjectsGroup + } + + GROUP vtpTrunkPruningGroup + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpTrunkPruningGroup2 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpTrunkPortGroup2 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + GROUP vtpTrunkPortGroup3 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtp4kVlanGroupRev1 + DESCRIPTION + "This group must be implemented by the VTP Servers + which support the range of VlanIndex between 1024 + and 4095." + + GROUP vtpVlanIfIndexGroup + DESCRIPTION + "This group is an optional group containing + objects providing information about the mapping + of VLAN ID to its corresponding IfIndex." + + GROUP vtpVlanInfoEditGroup2 + DESCRIPTION + "This group is mandatory for devices which only support + one VLAN editing for each 'apply' operation." + + GROUP vtpVlanNotifEnabledGroup + DESCRIPTION + "This group is mandatory for devices which support the + notifications/traps in vtpConfigNotificationsGroup3." + + GROUP vtpConfigNotificationsGroup2 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpConfigNotificationsGroup3 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpConfigNotificationsGroup4 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpDiscoverGroup + DESCRIPTION + "This group is mandatory for devices which support the + VTP discovery." + + GROUP vtpDatabaseGroup + DESCRIPTION + "This group is mandatory for devices which support the + VTP distribution of different database types." + + GROUP vtpAuthGroup + DESCRIPTION + "This group is mandatory for devices which support + asymmetric keys authentication mechanism for VTP." + + GROUP vtpInternalVlanGrp + DESCRIPTION + "Implementation of this group is optional." + + GROUP vlanStatsGroup + DESCRIPTION + "This group is mandatory for agents capable of + providing VLAN statistics information." + + GROUP vtpConfigNotificationsGroup6 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpConfigNotificationsGroup7 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpTrunkPruningGroup3 + DESCRIPTION + "This group is mandatory for devices which + support operational VTP pruning state." + + GROUP vtpConfigNotificationsGroup8 + DESCRIPTION + "This group is mandatory for devices which + support the notification generation on operational + VTP pruning state change." + + GROUP vlanTrunkPortActiveVlansGroup + DESCRIPTION + "This group is mandatory for devices capable of + providing active vlans information for trunk + capable ports." + + OBJECT vtpNotificationsEnabled + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanCreatedNotifEnabled + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanDeletedNotifEnabled + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainName + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainLocalMode + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainRowStatus + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainTftpServer + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainTftpPathname + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainPruningState + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainVersionInUse + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpInternalVlanAllocPolicy + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditOperation + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditBufferOwner + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditConfigRevNumber + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditState + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditName + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditMtu + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditDot10Said + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditRingNumber + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditBridgeNumber + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditStpType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditParentVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditRowStatus + SYNTAX INTEGER { + active(1) + } + WRITE-SYNTAX INTEGER { + createAndGo(4), + destroy(6) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. + + Support for createAndWait and notInService is not required." + + OBJECT vtpVlanEditTranslationalVlan1 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditTranslationalVlan2 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditBridgeType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditAreHopCount + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditSteHopCount + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditIsCRFBackup + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditTypeExt2 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVlansEnabled + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortRowStatus + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVlansPruningEligible + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortDynamicState + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVtpEnabled + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVlansEnabled2k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVlansEnabled3k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVlansEnabled4k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlansPruningEligible2k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlansPruningEligible3k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlansPruningEligible4k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortSetSerialNo + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpDiscoverAction + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpDatabaseLocalMode + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpDatabaseTakeOverPrimary + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpDatabaseTakeOverPassword + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpAuthPassword + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpAuthPasswordType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpAuthSecretKey + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { vtpMIBCompliances 15 } + +vtpMIBCompliance16 MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for VTP implementations." + MODULE -- this module + MANDATORY-GROUPS { + vtpBasicGroup, + vtpVlanInfoGroup, + vtpConfigNotificationsGroupRev1, + vtpStatsGroup, + vtpTrunkPortGroup, + vtpVersion2BasicGroup, + vtpNotificationObjectsGroup + } + + GROUP vtpTrunkPruningGroup + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpTrunkPruningGroup2 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpTrunkPortGroup2 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpVlanInfoEditGroup + DESCRIPTION + "This group must be implemented by VTP Servers. + VTP Clients need not implement these objects, and + must not allow VLANs to be created, modified, or + destroyed using these objects." + + GROUP vtpTrunkPortGroup3 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtp4kVlanGroupRev1 + DESCRIPTION + "This group must be implemented by the VTP Servers + which support the range of VlanIndex between 1024 + and 4095." + + GROUP vtpVlanIfIndexGroup + DESCRIPTION + "This group is an optional group containing + objects providing information about the mapping + of VLAN ID to its corresponding IfIndex." + + GROUP vtpVlanInfoEditGroup2 + DESCRIPTION + "This group is mandatory for devices which only support + one VLAN editing for each 'apply' operation." + + GROUP vtpVlanNotifEnabledGroup + DESCRIPTION + "This group is mandatory for devices which support the + notifications/traps in vtpConfigNotificationsGroup3." + + GROUP vtpConfigNotificationsGroup2 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpConfigNotificationsGroup3 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpConfigNotificationsGroup4 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpDiscoverGroup + DESCRIPTION + "This group is mandatory for devices which support the + VTP discovery." + + GROUP vtpDatabaseGroup + DESCRIPTION + "This group is mandatory for devices which support the + VTP distribution of different database types." + + GROUP vtpAuthGroup + DESCRIPTION + "This group is mandatory for devices which support + asymmetric keys authentication mechanism for VTP." + + GROUP vtpInternalVlanGrp + DESCRIPTION + "Implementation of this group is optional." + + GROUP vlanStatsGroup + DESCRIPTION + "This group is mandatory for agents capable of + providing VLAN statistics information." + + GROUP vtpConfigNotificationsGroup6 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpConfigNotificationsGroup7 + DESCRIPTION + "Implementation of this group is optional." + + GROUP vtpTrunkPruningGroup3 + DESCRIPTION + "This group is mandatory for devices which + support operational VTP pruning state." + + GROUP vtpConfigNotificationsGroup8 + DESCRIPTION + "This group is mandatory for devices which + support the notification generation on operational + VTP pruning state change." + + GROUP vlanTrunkPortActiveVlansGroup + DESCRIPTION + "This group is mandatory for devices capable of + providing active VLANs information for trunk + capable ports." + + GROUP vtpSourceInterfaceGroup + DESCRIPTION + "This group is mandatory for devices which support the + VTP IP updater address preferred source interface." + + GROUP vtpConfigFileGroup + DESCRIPTION + "This group is mandatory for devices which support the + location of VTP configuration file." + + GROUP vtpVlanLocalShutdownGroup + DESCRIPTION + "This group is mandatory for devices which support the + vlan local shutdown feature." + + GROUP vtpLocalUpdaterGroup + DESCRIPTION + "This group is mandatory for devices which support the + local updater IP address feature." + + GROUP vtpDeviceIdGroup + DESCRIPTION + "This group is mandatory for devices which support the + device identifier used by VTP domain." + + OBJECT vtpNotificationsEnabled + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanCreatedNotifEnabled + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanDeletedNotifEnabled + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainName + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainLocalMode + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainRowStatus + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainTftpServer + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainTftpPathname + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainPruningState + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainVersionInUse + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpInternalVlanAllocPolicy + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditOperation + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditBufferOwner + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditConfigRevNumber + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditState + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditName + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditMtu + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditDot10Said + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditRingNumber + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditBridgeNumber + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditStpType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditParentVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditRowStatus + SYNTAX INTEGER { + active(1) + } + WRITE-SYNTAX INTEGER { + createAndGo(4), + destroy(6) + } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. + + Support for createAndWait and notInService is not required." + + OBJECT vtpVlanEditTranslationalVlan1 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditTranslationalVlan2 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditBridgeType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditAreHopCount + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditSteHopCount + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditIsCRFBackup + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanEditTypeExt2 + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortManagementDomain + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortEncapsulationType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVlansEnabled + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortNativeVlan + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortRowStatus + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVlansPruningEligible + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortDynamicState + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVtpEnabled + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVlansEnabled2k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVlansEnabled3k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortVlansEnabled4k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlansPruningEligible2k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlansPruningEligible3k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlansPruningEligible4k + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vlanTrunkPortSetSerialNo + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpDiscoverAction + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpDatabaseLocalMode + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpDatabaseTakeOverPrimary + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpDatabaseTakeOverPassword + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpAuthPassword + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpAuthPasswordType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpAuthSecretKey + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainAdminSrcIf + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT managementDomainConfigFile + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT vtpVlanLocalShutdown + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { vtpMIBCompliances 16 } + +-- units of conformance + +vtpBasicGroup OBJECT-GROUP + OBJECTS { + vtpVersion, + vtpMaxVlanStorage, + vtpNotificationsEnabled, + managementDomainName, + managementDomainLocalMode, + managementDomainConfigRevNumber, + managementDomainLastUpdater, + managementDomainLastChange, + managementDomainTftpServer, + managementDomainTftpPathname, + managementDomainRowStatus + } + STATUS current + DESCRIPTION + "A collection of objects providing basic status and control + of a VTP implementation." + ::= { vtpMIBGroups 1 } + +vtpVlanInfoGroup OBJECT-GROUP + OBJECTS { + vtpVlanState, + vtpVlanType, + vtpVlanName, + vtpVlanMtu, + vtpVlanDot10Said, + vtpVlanRingNumber, + vtpVlanBridgeNumber, + vtpVlanStpType, + vtpVlanParentVlan, + vtpVlanTranslationalVlan1, + vtpVlanTranslationalVlan2, + vtpVlanBridgeType, + vtpVlanAreHopCount, + vtpVlanSteHopCount, + vtpVlanIsCRFBackup + } + STATUS current + DESCRIPTION + "A collection of objects for monitoring VLAN information." + ::= { vtpMIBGroups 13 } + +vtpVlanInfoEditGroup OBJECT-GROUP + OBJECTS { + vtpVlanEditOperation, + vtpVlanApplyStatus, + vtpVlanEditBufferOwner, + vtpVlanEditConfigRevNumber, + vtpVlanEditState, + vtpVlanEditType, + vtpVlanEditName, + vtpVlanEditMtu, + vtpVlanEditDot10Said, + vtpVlanEditRingNumber, + vtpVlanEditBridgeNumber, + vtpVlanEditStpType, + vtpVlanEditParentVlan, + vtpVlanEditRowStatus, + vtpVlanEditTranslationalVlan1, + vtpVlanEditTranslationalVlan2, + vtpVlanEditBridgeType, + vtpVlanEditAreHopCount, + vtpVlanEditSteHopCount, + vtpVlanEditIsCRFBackup + } + STATUS current + DESCRIPTION + "A collection of objects for editing VLAN information in VTP + Servers." + ::= { vtpMIBGroups 14 } + +vtpStatsGroup OBJECT-GROUP + OBJECTS { + vtpInSummaryAdverts, + vtpInSubsetAdverts, + vtpInAdvertRequests, + vtpOutSummaryAdverts, + vtpOutSubsetAdverts, + vtpOutAdvertRequests, + vtpConfigRevNumberErrors, + vtpConfigDigestErrors + } + STATUS current + DESCRIPTION + "A collection of objects providing VTP statistics." + ::= { vtpMIBGroups 4 } + +vtpTrunkPortGroup OBJECT-GROUP + OBJECTS { + vlanTrunkPortManagementDomain, + vlanTrunkPortEncapsulationType, + vlanTrunkPortVlansEnabled, + vlanTrunkPortNativeVlan, + vlanTrunkPortRowStatus, + vlanTrunkPortSetSerialNo + } + STATUS current + DESCRIPTION + "A collection of objects providing information on trunk + ports." + ::= { vtpMIBGroups 5 } + +vtpTrunkPortGroup2 OBJECT-GROUP + OBJECTS { + vlanTrunkPortDynamicState, + vlanTrunkPortDynamicStatus, + vlanTrunkPortVtpEnabled + } + STATUS current + DESCRIPTION + "Additional functionality added to the + vlanTrunkPortTable." + ::= { vtpMIBGroups 11 } + +vtpTrunkPortGroup3 OBJECT-GROUP + OBJECTS { vlanTrunkPortEncapsulationOperType } + STATUS current + DESCRIPTION + "Additional functionality added to the + vlanTrunkPortTable." + ::= { vtpMIBGroups 15 } + +vtpTrunkPruningGroup OBJECT-GROUP + OBJECTS { + vlanTrunkPortInJoins, + vlanTrunkPortOutJoins, + vlanTrunkPortOldAdverts, + vlanTrunkPortVlansPruningEligible, + vlanTrunkPortVlansXmitJoined, + vlanTrunkPortVlansRcvJoined + } + STATUS current + DESCRIPTION + "A collection of objects providing information on VLAN + pruning." + ::= { vtpMIBGroups 7 } + +vtpTrunkPruningGroup2 OBJECT-GROUP + OBJECTS { managementDomainPruningState } + STATUS current + DESCRIPTION + "A collection of object providing information on whether + VLAN pruning is enabled." + ::= { vtpMIBGroups 10 } + +vtpVersion2BasicGroup OBJECT-GROUP + OBJECTS { managementDomainVersionInUse } + STATUS current + DESCRIPTION + "The object required to indicate the version of VTP in + use by a management domain." + ::= { vtpMIBGroups 12 } + +vtpConfigNotificationsGroup NOTIFICATION-GROUP + NOTIFICATIONS { + vtpConfigDigestError, + vtpConfigRevNumberError, + vtpServerDisabled, + vtpMtuTooBig, + vtpVersionOneDeviceDetected, + vlanTrunkPortDynamicStatusChange + } + STATUS deprecated + DESCRIPTION + "The notifications which a VTP implementation is + required to implement. + vtpConfigNotificationsGroup object is superseded by vtpConfigNotificationsGroupRev1, vtpConfigNotificationsGroup5." + ::= { vtpMIBGroups 6 } + +vtp4kVlanGroup OBJECT-GROUP + OBJECTS { + vtpVlanTypeExt, + vtpVlanEditTypeExt, + vlanTrunkPortVlansEnabled2k, + vlanTrunkPortVlansEnabled3k, + vlanTrunkPortVlansEnabled4k, + vtpVlansPruningEligible2k, + vtpVlansPruningEligible3k, + vtpVlansPruningEligible4k, + vlanTrunkPortVlansXmitJoined2k, + vlanTrunkPortVlansXmitJoined3k, + vlanTrunkPortVlansXmitJoined4k, + vlanTrunkPortVlansRcvJoined2k, + vlanTrunkPortVlansRcvJoined3k, + vlanTrunkPortVlansRcvJoined4k + } + STATUS deprecated + DESCRIPTION + "A collection of objects providing information + for VLANS with VlanIndex from 1024 to 4095. + vtp4kVlanGroup object is superseded by vtp4kVlanGroupRev1." + ::= { vtpMIBGroups 16 } + +vtpDot1qTunnelGroup OBJECT-GROUP + OBJECTS { + vlanTrunkPortsDot1qTag, + vlanTrunkPortDot1qTunnel + } + STATUS deprecated + DESCRIPTION + "A collection of objects providing information + for dot1qtunnel feature. + vtpDot1qTunnelGroup object is superseded by vtpDot1qTunnelGroup2." + ::= { vtpMIBGroups 17 } + +vtpVlanIfIndexGroup OBJECT-GROUP + OBJECTS { vtpVlanIfIndex } + STATUS current + DESCRIPTION + "A collection of objects providing information + for mapping of VLAN ID to its corresponding + ifIndex." + ::= { vtpMIBGroups 18 } + +vtpVlanInfoEditGroup2 OBJECT-GROUP + OBJECTS { vtpVlanEditModifiedVlan } + STATUS current + DESCRIPTION + "A collection of objects for editing VLAN information when + only one VLAN is allowed to be edited for each 'apply' + operation." + ::= { vtpMIBGroups 19 } + +vtp4kVlanGroupRev1 OBJECT-GROUP + OBJECTS { + vtpVlanTypeExt, + vtpVlanEditTypeExt2, + vlanTrunkPortVlansEnabled2k, + vlanTrunkPortVlansEnabled3k, + vlanTrunkPortVlansEnabled4k, + vtpVlansPruningEligible2k, + vtpVlansPruningEligible3k, + vtpVlansPruningEligible4k, + vlanTrunkPortVlansXmitJoined2k, + vlanTrunkPortVlansXmitJoined3k, + vlanTrunkPortVlansXmitJoined4k, + vlanTrunkPortVlansRcvJoined2k, + vlanTrunkPortVlansRcvJoined3k, + vlanTrunkPortVlansRcvJoined4k + } + STATUS current + DESCRIPTION + "A collection of objects providing information + for VLANS with VlanIndex from 1024 to 4095." + ::= { vtpMIBGroups 20 } + +vtpNotificationObjectsGroup OBJECT-GROUP + OBJECTS { vtpVlanPortLocalSegment } + STATUS current + DESCRIPTION + "A collection of objects included in VTP notifications." + ::= { vtpMIBGroups 21 } + +vtpDot1qTunnelGroup2 OBJECT-GROUP + OBJECTS { vlanTrunkPortsDot1qTag } + STATUS deprecated + DESCRIPTION + "A collection of objects providing information + for dot1qtunnel feature." + ::= { vtpMIBGroups 22 } + +vtpConfigNotificationsGroup2 NOTIFICATION-GROUP + NOTIFICATIONS { + vtpLocalModeChanged, + vtpVersionInUseChanged + } + STATUS current + DESCRIPTION + "The notifications which a VTP implementation is + required to implement." + ::= { vtpMIBGroups 23 } + +vtpVlanNotifEnabledGroup OBJECT-GROUP + OBJECTS { + vtpVlanCreatedNotifEnabled, + vtpVlanDeletedNotifEnabled + } + STATUS current + DESCRIPTION + "A collection of objects to indicate whether a + certain group of notifications are enabled." + ::= { vtpMIBGroups 24 } + +vtpConfigNotificationsGroup3 NOTIFICATION-GROUP + NOTIFICATIONS { + vtpVlanCreated, + vtpVlanDeleted + } + STATUS current + DESCRIPTION + "The notifications implemented by a device which + supports these features." + ::= { vtpMIBGroups 25 } + +vtpConfigNotificationsGroup4 NOTIFICATION-GROUP + NOTIFICATIONS { vtpVlanRingNumberConflict } + STATUS current + DESCRIPTION + "The notifications implemented by a device which + supports these features." + ::= { vtpMIBGroups 26 } + +vtpDiscoverGroup OBJECT-GROUP + OBJECTS { + vtpDiscoverAction, + vtpDiscoverStatus, + vtpLastDiscoverTime, + vtpDiscoverResultIndex, + vtpDiscoverResultDatabaseName, + vtpDiscoverResultConflicting, + vtpDiscoverResultDeviceId, + vtpDiscoverResultPrimaryServer, + vtpDiscoverResultRevNumber, + vtpDiscoverResultSystemName + } + STATUS current + DESCRIPTION + "A collection of objects providing information of + VTP discovery." + ::= { vtpMIBGroups 27 } + +vtpDatabaseGroup OBJECT-GROUP + OBJECTS { + vtpDatabaseName, + vtpDatabaseLocalMode, + vtpDatabaseRevNumber, + vtpDatabasePrimaryServer, + vtpDatabasePrimaryServerId, + vtpDatabaseTakeOverPrimary, + vtpDatabaseTakeOverPassword + } + STATUS current + DESCRIPTION + "A collection of objects providing information of + VTP databases." + ::= { vtpMIBGroups 28 } + +vtpAuthGroup OBJECT-GROUP + OBJECTS { + vtpAuthPassword, + vtpAuthPasswordType, + vtpAuthSecretKey + } + STATUS current + DESCRIPTION + "A collection of objects providing information of + VTP authentication mechanism." + ::= { vtpMIBGroups 29 } + +vtpConfigNotificationsGroupRev1 NOTIFICATION-GROUP + NOTIFICATIONS { + vtpConfigDigestError, + vtpConfigRevNumberError, + vtpVersionOneDeviceDetected, + vlanTrunkPortDynamicStatusChange + } + STATUS current + DESCRIPTION + "The notifications which a VTP implementation is + required to implement." + ::= { vtpMIBGroups 30 } + +vtpConfigNotificationsGroup5 NOTIFICATION-GROUP + NOTIFICATIONS { + vtpServerDisabled, + vtpMtuTooBig + } + STATUS deprecated + DESCRIPTION + "The additional notifications that may be + related to a VTP implementation. + vtpConfigNotificationsGroup5 object is superseded by vtpConfigNotificationsGroup6, vtpConfigNotificationsGroup7." + ::= { vtpMIBGroups 31 } + +vtpInternalVlanGrp OBJECT-GROUP + OBJECTS { + vtpInternalVlanAllocPolicy, + vtpInternalVlanOwner + } + STATUS current + DESCRIPTION + "A collection of objects providing information of + internal VLANs." + ::= { vtpMIBGroups 32 } + +vlanStatsGroup OBJECT-GROUP + OBJECTS { + vlanStatsVlans, + vlanStatsExtendedVlans, + vlanStatsInternalVlans, + vlanStatsFreeVlans + } + STATUS current + DESCRIPTION + "A collection of objects providing VLAN statistics + information in the system." + ::= { vtpMIBGroups 33 } + +vtpConfigNotificationsGroup6 NOTIFICATION-GROUP + NOTIFICATIONS { vtpServerDisabled } + STATUS current + DESCRIPTION + "The additional notifications that may be + related to a VTP implementation." + ::= { vtpMIBGroups 34 } + +vtpConfigNotificationsGroup7 NOTIFICATION-GROUP + NOTIFICATIONS { vtpMtuTooBig } + STATUS current + DESCRIPTION + "The additional notifications that may be + related to a VTP implementation." + ::= { vtpMIBGroups 35 } + +vtpTrunkPruningGroup3 OBJECT-GROUP + OBJECTS { managementDomainPruningStateOper } + STATUS current + DESCRIPTION + "A collection of objects providing information on + operational VTP pruning state in a manamgement domain." + ::= { vtpMIBGroups 36 } + +vtpConfigNotificationsGroup8 NOTIFICATION-GROUP + NOTIFICATIONS { vtpPruningStateOperChange } + STATUS current + DESCRIPTION + "The additional notifications for operational + VTP pruning state change in a management domain." + ::= { vtpMIBGroups 37 } + +vlanTrunkPortActiveVlansGroup OBJECT-GROUP + OBJECTS { + vlanTrunkPortVlansActiveFirst2k, + vlanTrunkPortVlansActiveSecond2k + } + STATUS current + DESCRIPTION + "A collection of objects providing active vlan + information for a trunking port in a management + domain." + ::= { vtpMIBGroups 38 } + +vtpSourceInterfaceGroup OBJECT-GROUP + OBJECTS { + managementDomainAdminSrcIf, + managementDomainSourceOnlyMode, + managementDomainOperSrcIf + } + STATUS current + DESCRIPTION + "A collection of object providing the preferred source + interface for the VTP IP updater address." + ::= { vtpMIBGroups 39 } + +vtpConfigFileGroup OBJECT-GROUP + OBJECTS { managementDomainConfigFile } + STATUS current + DESCRIPTION + "A collection of object providing the location of VTP + configuration file." + ::= { vtpMIBGroups 40 } + +vtpVlanLocalShutdownGroup OBJECT-GROUP + OBJECTS { vtpVlanLocalShutdown } + STATUS current + DESCRIPTION + "A collection of object providing the VLAN local shutdown + state." + ::= { vtpMIBGroups 41 } + +vtpLocalUpdaterGroup OBJECT-GROUP + OBJECTS { + managementDomainLocalUpdaterType, + managementDomainLocalUpdater + } + STATUS current + DESCRIPTION + "A collection of object providing the local updater IP address." + ::= { vtpMIBGroups 42 } + +vtpDeviceIdGroup OBJECT-GROUP + OBJECTS { managementDomainDeviceID } + STATUS current + DESCRIPTION + "A collection of object providing the device id." + ::= { vtpMIBGroups 43 } + +END + + + + + + + + + diff --git a/MIBs/anx_mib_121.txt b/MIBs/anx_mib_121.txt new file mode 100644 index 0000000..7536537 --- /dev/null +++ b/MIBs/anx_mib_121.txt @@ -0,0 +1,4445 @@ +Webio-ANx-MIB DEFINITIONS ::= BEGIN +---------------------------------------------------------------- +-- Revison: 1.20 +---------------------------------------------------------------- +-- 23.03.2006 #57601, WebThermometer +-- Alarmtrigger: Rate of Change, Delay Time +---------------------------------------------------------------- +-- Revison: 1.20 +---------------------------------------------------------------- +-- 02.06.2005 #57601/3/4, WebThermometer +-- Trap NMS annotations +---------------------------------------------------------------- +-- Revison: 1.19 +---------------------------------------------------------------- +-- 18.04.2005 HTTP-Port einstellbar +-- +---------------------------------------------------------------- +-- Revison: 1.18 +---------------------------------------------------------------- +-- 14.07.2004 Trennung nach Produktfamilien +-- +---------------------------------------------------------------- +-- Revison: 1.17 +---------------------------------------------------------------- +-- 28.06.2004 #57630/1/2, Webio Digital +-- Neu: Puls Mode +---------------------------------------------------------------- +-- Revison: 1.16 +---------------------------------------------------------------- +-- 16.04.2004 neu: #57632, Webio Digital EA24x24 +-- +-- #57630/1, Webio Digital EA12x12 +-- Neu: +-- wtWebioEA12x12InputCounterClear +---------------------------------------------------------------- +-- Revison: 1.15 +---------------------------------------------------------------- +-- 27.02.2004 #57630/1, Webio Digital EA12x12 +-- Neu: +-- Länge erweitert auf 32 Bit: +-- wtWebioEA12x12InputValue +-- wtWebioEA12x12OutputValue +-- wtWebioEA12x12LoadControlView +-- wtWebioEA12x12LCShutDownView +-- wtWebioEA12x12SetOutput +-- wtWebioEA12x12AlarmInputTrigger +-- wtWebioEA12x12AlarmOutputTrigger +-- wtWebioEA12x12PortOutputSafetyState +---------------------------------------------------------------- +-- Revison: 1.14 +---------------------------------------------------------------- +-- 16.02.2004 #57630/1, Webio Digital EA12x12 +-- Neu: +-- Texte: Location, Contact +-- SNMP: ColdStart, WarmStart, ComunityString Read/RW +-- Alarm: ColdStart / WarmStart trigger +-- +-- #57601, 1xWebThermometer +-- #57603, 2xWebThermometer +-- #57604, 8xWebThermometer +-- Neu: +-- Alarm Hysterese +-- Alarm Clear Traps und Mails +---------------------------------------------------------------- +-- Revison: 1.13 +---------------------------------------------------------------- +-- 05.02.2004 #57601, 1xWebThermometer +-- #57603, 2xWebThermometer +-- #57604, 8xWebThermometer +-- Neu: +-- Texte: Location, Contact +-- SNMP: ColdStart, WarmStart, ComunityString Read/RW +-- Alarm: ColdStart / WarmStart trigger +---------------------------------------------------------------- +-- Revison: 1.12 +---------------------------------------------------------------- +-- 05.11.2003 #57601, 1xWebThermometer +-- #57603, 2xWebThermometer +-- #57604, 8xWebThermometer +-- Neu: +-- Mail Option: CSV attachment +-- Offsetkalibrierung +-- Alarm: Tcp Client mode +---------------------------------------------------------------- +-- Revison: 1.11 +---------------------------------------------------------------- +-- 28.10.2003 #57630/1, Webio Digital EA12x12 +-- Neue Feature: +-- Alarm : TCP Client mode +-- INPUTS: Pulsfilter +---------------------------------------------------------------- +-- Revison: 1.10 +---------------------------------------------------------------- +-- 04.07.2003 #57630, Webio Digital EA12x12 +-- Neuer Menübaum, neue Binärmodi +-- +---------------------------------------------------------------- +-- Revison: 1.09 +---------------------------------------------------------------- +-- 24.03.2003 Trap Enterprise (Type 1, 2) korrigiert +-- +---------------------------------------------------------------- +-- Revison: 1.08 +---------------------------------------------------------------- +-- 04.03.2003 Abgleich der Sprachversionen DE/US +-- +---------------------------------------------------------------- +-- Revison: 1.07 +---------------------------------------------------------------- +-- 25.02.2003 Korrektur US: wtWebioEA12x12LoadControl +---------------------------------------------------------------- +-- Revison: 1.06 +---------------------------------------------------------------- +-- 24.02.2003 Neu: +-- #57630, Webio EA12x12, LoadControl Group +-- Korrektur: Trap variable Namen +---------------------------------------------------------------- +-- Revison: 1.05 +---------------------------------------------------------------- +-- 21.01.2003 Neu: +-- #57630, Webio EA12x12 +---------------------------------------------------------------- +-- Revison: 1.04 +---------------------------------------------------------------- +-- 02.01.2003 Neu: +-- #57601, 1xWebThermometer +-- #57603, 2xWebThermometer, 8 Alarme +---------------------------------------------------------------- +-- Revison: 1.03 +---------------------------------------------------------------- +-- 21.11.2002 Neu: +-- #57604, 2xWebThermometer, BOOTP, StartupSite +-- #57603, 8xWebThermometer, BOOTP, StartupSite +---------------------------------------------------------------- +-- Revison: 1.02 +---------------------------------------------------------------- +-- 26.07.2002 Neu: +-- #57604, 2xWebThermometer +-- #57603, 8xWebThermometer +-- + + IMPORTS + + OBJECT-TYPE FROM RFC-1212 + TRAP-TYPE FROM RFC-1215 + DisplayString, PhysAddress FROM RFC1213-MIB + enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI; + + +-- IpAddress ::= +-- [APPLICATION 0] +-- IMPLICIT OCTET STRING (SIZE (4)) +-- Counter ::= +-- [APPLICATION 1] +-- IMPLICIT INTEGER (0..4294967295) +-- Gauge ::= +-- [APPLICATION 2] +-- IMPLICIT INTEGER (0..4294967295) +-- TimeTicks ::= +-- [APPLICATION 3] +-- IMPLICIT INTEGER (0..4294967295) + + +-- DisplayString ::= OCTET STRING +-- PhysAddress ::= OCTET STRING + +-- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } +-- privat OBJECT IDENTIFIER ::= { internet 4 } +-- enterprises OBJECT IDENTIFIER ::= { privat 1 } + + + +-- Wiesemann & Theis Com-Server MIB + + wut OBJECT IDENTIFIER ::= { enterprises 5040 } + wtComServer OBJECT IDENTIFIER ::= { wut 1 } + wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 } + + +-- wtWebio Tree + + wtWebioAn8 OBJECT IDENTIFIER ::= { wtWebio 1 } + wtWebioAn2 OBJECT IDENTIFIER ::= { wtWebio 2 } + wtWebioAn1 OBJECT IDENTIFIER ::= { wtWebio 3 } + +-- wtWebioAn8 Tree + + wtWebioAn8Temp OBJECT IDENTIFIER ::= { wtWebioAn8 1 } + wtWebioAn8SessCntrl OBJECT IDENTIFIER ::= { wtWebioAn8 2 } + wtWebioAn8Config OBJECT IDENTIFIER ::= { wtWebioAn8 3 } + +-- wtWebioAn8Config Tree + + wtWebioAn8Device OBJECT IDENTIFIER ::= { wtWebioAn8Config 1 } + wtWebioAn8Ports OBJECT IDENTIFIER ::= { wtWebioAn8Config 2 } + wtWebioAn8Manufact OBJECT IDENTIFIER ::= { wtWebioAn8Config 3 } + + +-- wtWebioAn8Device Tree + + wtWebioAn8Network OBJECT IDENTIFIER ::= { wtWebioAn8Device 1 } + wtWebioAn8Text OBJECT IDENTIFIER ::= { wtWebioAn8Device 2 } + wtWebioAn8TimeDate OBJECT IDENTIFIER ::= { wtWebioAn8Device 3 } + wtWebioAn8MailAdmin OBJECT IDENTIFIER ::= { wtWebioAn8Device 4 } + wtWebioAn8Alarm OBJECT IDENTIFIER ::= { wtWebioAn8Device 5 } + wtWebioAn8Datalogger OBJECT IDENTIFIER ::= { wtWebioAn8Device 6 } + wtWebioAn8Protocol OBJECT IDENTIFIER ::= { wtWebioAn8Device 7 } + wtWebioAn8Enable OBJECT IDENTIFIER ::= { wtWebioAn8Device 8 } + wtWebioAn8Startup OBJECT IDENTIFIER ::= { wtWebioAn8Device 9 } + +-- wtWebioAn8TimeDate Tree + + wtWebioAn8TimeZone OBJECT IDENTIFIER ::= { wtWebioAn8TimeDate 1 } + wtWebioAn8TimeServer OBJECT IDENTIFIER ::= { wtWebioAn8TimeDate 2 } + wtWebioAn8DeviceClock OBJECT IDENTIFIER ::= { wtWebioAn8TimeDate 3 } + +-- wtWebioAn8Protocol Group + wtWebioAn8PrtclUDP OBJECT IDENTIFIER ::= { wtWebioAn8Protocol 1 } + wtWebioAn8PrtclSNMP OBJECT IDENTIFIER ::= { wtWebioAn8Protocol 2 } + wtWebioAn8PrtclHTTP OBJECT IDENTIFIER ::= { wtWebioAn8Protocol 3 } + +-- wtWebioAn2 Tree + + wtWebioAn2Temp OBJECT IDENTIFIER ::= { wtWebioAn2 1 } + wtWebioAn2SessCntrl OBJECT IDENTIFIER ::= { wtWebioAn2 2 } + wtWebioAn2Config OBJECT IDENTIFIER ::= { wtWebioAn2 3 } + +-- wtWebioAn2Config Tree + + wtWebioAn2Device OBJECT IDENTIFIER ::= { wtWebioAn2Config 1 } + wtWebioAn2Ports OBJECT IDENTIFIER ::= { wtWebioAn2Config 2 } + wtWebioAn2Manufact OBJECT IDENTIFIER ::= { wtWebioAn2Config 3 } + + +-- wtWebioAn2Device Tree + + wtWebioAn2Network OBJECT IDENTIFIER ::= { wtWebioAn2Device 1 } + wtWebioAn2Text OBJECT IDENTIFIER ::= { wtWebioAn2Device 2 } + wtWebioAn2TimeDate OBJECT IDENTIFIER ::= { wtWebioAn2Device 3 } + wtWebioAn2MailAdmin OBJECT IDENTIFIER ::= { wtWebioAn2Device 4 } + wtWebioAn2Alarm OBJECT IDENTIFIER ::= { wtWebioAn2Device 5 } + wtWebioAn2Datalogger OBJECT IDENTIFIER ::= { wtWebioAn2Device 6 } + wtWebioAn2Protocol OBJECT IDENTIFIER ::= { wtWebioAn2Device 7 } + wtWebioAn2Enable OBJECT IDENTIFIER ::= { wtWebioAn2Device 8 } + wtWebioAn2Startup OBJECT IDENTIFIER ::= { wtWebioAn2Device 9 } + +-- wtWebioAn2TimeDate Tree + + wtWebioAn2TimeZone OBJECT IDENTIFIER ::= { wtWebioAn2TimeDate 1 } + wtWebioAn2TimeServer OBJECT IDENTIFIER ::= { wtWebioAn2TimeDate 2 } + wtWebioAn2DeviceClock OBJECT IDENTIFIER ::= { wtWebioAn2TimeDate 3 } + +-- wtWebioAn2Protocol Group + wtWebioAn2PrtclUDP OBJECT IDENTIFIER ::= { wtWebioAn2Protocol 1 } + wtWebioAn2PrtclSNMP OBJECT IDENTIFIER ::= { wtWebioAn2Protocol 2 } + wtWebioAn2PrtclHTTP OBJECT IDENTIFIER ::= { wtWebioAn2Protocol 3 } + +-- wtWebioAn1 Tree + + wtWebioAn1Temp OBJECT IDENTIFIER ::= { wtWebioAn1 1 } + wtWebioAn1SessCntrl OBJECT IDENTIFIER ::= { wtWebioAn1 2 } + wtWebioAn1Config OBJECT IDENTIFIER ::= { wtWebioAn1 3 } + +-- wtWebioAn1Config Tree + + wtWebioAn1Device OBJECT IDENTIFIER ::= { wtWebioAn1Config 1 } + wtWebioAn1Ports OBJECT IDENTIFIER ::= { wtWebioAn1Config 2 } + wtWebioAn1Manufact OBJECT IDENTIFIER ::= { wtWebioAn1Config 3 } + +-- wtWebioAn1Device Tree + + wtWebioAn1Network OBJECT IDENTIFIER ::= { wtWebioAn1Device 1 } + wtWebioAn1Text OBJECT IDENTIFIER ::= { wtWebioAn1Device 2 } + wtWebioAn1TimeDate OBJECT IDENTIFIER ::= { wtWebioAn1Device 3 } + wtWebioAn1MailAdmin OBJECT IDENTIFIER ::= { wtWebioAn1Device 4 } + wtWebioAn1Alarm OBJECT IDENTIFIER ::= { wtWebioAn1Device 5 } + wtWebioAn1Datalogger OBJECT IDENTIFIER ::= { wtWebioAn1Device 6 } + wtWebioAn1Protocol OBJECT IDENTIFIER ::= { wtWebioAn1Device 7 } + wtWebioAn1Enable OBJECT IDENTIFIER ::= { wtWebioAn1Device 8 } + wtWebioAn1Startup OBJECT IDENTIFIER ::= { wtWebioAn1Device 9 } + +-- wtWebioAn1TimeDate Tree + + wtWebioAn1TimeZone OBJECT IDENTIFIER ::= { wtWebioAn1TimeDate 1 } + wtWebioAn1TimeServer OBJECT IDENTIFIER ::= { wtWebioAn1TimeDate 2 } + wtWebioAn1DeviceClock OBJECT IDENTIFIER ::= { wtWebioAn1TimeDate 3 } + +-- wtWebioAn1Protocol Group + wtWebioAn1PrtclUDP OBJECT IDENTIFIER ::= { wtWebioAn1Protocol 1 } + wtWebioAn1PrtclSNMP OBJECT IDENTIFIER ::= { wtWebioAn1Protocol 2 } + wtWebioAn1PrtclHTTP OBJECT IDENTIFIER ::= { wtWebioAn1Protocol 3 } + +-------------------------------------------------------------------------------- +-------------------------------------------------------------------------------- +-------------------------------------------------------------------------------- +-- Webio Bereich +-- Alle Anfragen werden vom ComServer Modul an die Webio Plattform weitergeleitet +-------------------------------------------------------------------------------- +-------------------------------------------------------------------------------- +-------------------------------------------------------------------------------- + +-- wtWebioAn8Temp Group +------------------------ + +wtWebioAn8Sensors OBJECT-TYPE + SYNTAX INTEGER (1..8) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Anzahl der Temperatursensoren" + ::= { wtWebioAn8Temp 1 } + +-- Interface Table + +wtWebioAn8SensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn8SensorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Sensoren." + ::= { wtWebioAn8Temp 2 } + +wtWebioAn8SensorEntry OBJECT-TYPE + SYNTAX WtWebioAn8SensorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Nummern der Temperatursensoren." + INDEX { wtWebioAn8SensorNo } + ::= { wtWebioAn8SensorTable 1 } + +WtWebioAn8SensorEntry ::= SEQUENCE { + wtWebioAn8SensorNo INTEGER (1..8) +} + +wtWebioAn8SensorNo OBJECT-TYPE + SYNTAX INTEGER (1..8) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Nummer des Temperatursensors." + ::= { wtWebioAn8SensorEntry 1 } + + +-- wtWebioAn8TempValue Table + +wtWebioAn8TempValueTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn8TempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste Temperaturwerte korrespondiernd zu den Kanalnummern." + ::= { wtWebioAn8Temp 3 } + +wtWebioAn8TempValueEntry OBJECT-TYPE + SYNTAX WtWebioAn8TempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Temperaturen der Sensoren." + INDEX { wtWebioAn8SensorNo } + ::= { wtWebioAn8TempValueTable 1 } + +WtWebioAn8TempValueEntry ::= SEQUENCE{ + wtWebioAn8TempValue OCTET STRING (SIZE (5)) +} + +wtWebioAn8TempValue OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (5)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Temperaturwert des Sensors, ASCII, 5 Zeichen lang." + ::= { wtWebioAn8TempValueEntry 1 } + +-- wtWebioAn8BinaryTempValue Table + +wtWebioAn8BinaryTempValueTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn8BinaryTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste binärer Temperaturwerte korrespondiernd zu den Kanalnummern." + ::= { wtWebioAn8Temp 4 } + +wtWebioAn8BinaryTempValueEntry OBJECT-TYPE + SYNTAX WtWebioAn8BinaryTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Binäre Temperaturen der Sensoren." + INDEX { wtWebioAn8SensorNo } + ::= { wtWebioAn8BinaryTempValueTable 1 } + +WtWebioAn8BinaryTempValueEntry ::= SEQUENCE{ + wtWebioAn8BinaryTempValue INTEGER +} + +wtWebioAn8BinaryTempValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Binärer Temperaturwert des Sensors in 1/10 Grad Celcius, + vorzeichenbehaftete Zahl, der Wert 0x7FFF zeigt einen + ungültigen Messwert an." + ::= { wtWebioAn8BinaryTempValueEntry 1 } + +-- wtWebioAn8SessCntrl Group +-------------------------------- + +wtWebioAn8SessCntrlPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Durch Eintrag diese Passworts wird eine Session eröffnet, die durch Schreiben einer 1 + in wtWebioAn8SessCntrlLogout beendet wird. Gelesen liefert diese Variable einen String der + Länge Null." + ::= { wtWebioAn8SessCntrl 1 } + +wtWebioAn8SessCntrlConfigMode OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn8SessCntrl-NoSession(0), + wtWebioAn8SessCntrl-Session(1) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Wenn sich das Gerät im SNMP-Konfigurationsmodus befindet, wird der Wert + 1 zurückgeliefert, ansonsten 0. Ist der ausgelesene Wert 0 + obwohl das Passwort geschrieben wurde, befindet sich das Gerät bereits + im Configmodus und die Variablen können nur gelesen werden." + ::= { wtWebioAn8SessCntrl 2 } + +wtWebioAn8SessCntrlLogout OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Wenn sich das Gerät im Konfigurationsmodus befindet und die Session wurde + von diesem SNMP Manager eröffnet, kann durch Schreiben einer 1 in diese + Variable die Session beendet werden und alle Parameter werden gespeichert. + Durch Schreiben einer 2 werden alle Eingaben wieder verworfen. + Gelesen liefert diese Variable den Wert 0." + ::= { wtWebioAn8SessCntrl 3 } + +wtWebioAn8SessCntrlAdminPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieses Passwort schützt den Zugang der Variablen mit Administratorrechten. Es kann nur vom + Administrator verändert werden. Wurde kein Passwort vergeben so ist public das gültige Passwort. + Gelesen liefert diese Variable einen Null-Pointer." + ::= { wtWebioAn8SessCntrl 4 } + +wtWebioAn8SessCntrlConfigPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieses Passwort schützt den Zugang der Variablen mit Configuratorrechten. Es kann vom + Administrator und vom Configurator verändert werden. Wurde kein Passwort vergeben so ist + public das gültige Passwort.Gelesen liefert diese Variable einen Null-Pointer." + ::= { wtWebioAn8SessCntrl 5 } + + +-- wtWebioAn8Network Group +------------------------ + +wtWebioAn8IpAddress OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des Webio's" + ::= { wtWebioAn8Network 1 } + +wtWebioAn8SubnetMask OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Subnetmask des Webio's" + ::= { wtWebioAn8Network 2 } + +wtWebioAn8Gateway OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Gateway des Webio's" + ::= { wtWebioAn8Network 3 } + +wtWebioAn8DnsServer1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des 1. DNS Servers in ASCII" + ::= { wtWebioAn8Network 4 } + +wtWebioAn8DnsServer2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des 2. DNS Servers in ASCII" + ::= { wtWebioAn8Network 5 } + +wtWebioAn8AddConfig OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Zusatzkonfiguration (1=EIN): + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: BOOTP disable + " + ::= { wtWebioAn8Network 6 } + +-- wtWebioAn8Text Group +------------------------ + +wtWebioAn8DeviceName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name des Webio's, der userdefinierbar ist." + ::= { wtWebioAn8Text 1 } + +wtWebioAn8DeviceText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Beschreibung des Webio's, die userdefinierbar ist." + ::= { wtWebioAn8Text 2 } + +wtWebioAn8DeviceLocation OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Aufstellort des Webio's, die userdefinierbar ist." + ::= { wtWebioAn8Text 3 } + +wtWebioAn8DeviceContact OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Kontactadresse im Servicefall des Webio's, die userdefinierbar ist." + ::= { wtWebioAn8Text 4 } + +-- wtWebioAn8TimeZone Group +---------------------------- + +wtWebioAn8TzName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name der Zeitzone (Winterzeit)." + ::= { wtWebioAn8TimeZone 1 } + +wtWebioAn8TzOffsetHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Stunden der Zeitzone (Winterzeit) in Bezug auf UTC." + ::= { wtWebioAn8TimeZone 2 } + +wtWebioAn8TzOffsetMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Minuten der Zeitzone (Winterzeit) in Bezug auf UTC." + ::= { wtWebioAn8TimeZone 3 } + +wtWebioAn8StTzName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name der Zeitzone (Sommerzeit)." + ::= { wtWebioAn8TimeZone 4 } + +wtWebioAn8StTzOffsetHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Stunden der Zeitzone (Sommerzeit) in Bezug auf UTC." + ::= { wtWebioAn8TimeZone 5 } + +wtWebioAn8StTzOffsetMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Minuten der Zeitzone (Sommerzeit) in Bezug auf UTC." + ::= { wtWebioAn8TimeZone 6 } + +wtWebioAn8StTzStartMonth OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn8StartMonth-January(1), + wtWebioAn8StartMonth-February(2), + wtWebioAn8StartMonth-March(3), + wtWebioAn8StartMonth-April(4), + wtWebioAn8StartMonth-May(5), + wtWebioAn8StartMonth-June(6), + wtWebioAn8StartMonth-July(7), + wtWebioAn8StartMonth-August(8), + wtWebioAn8StartMonth-September(9), + wtWebioAn8StartMonth-October(10), + wtWebioAn8StartMonth-November(11), + wtWebioAn8StartMonth-December(12) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Monat, in dem von Winterzeit auf Sommerzeit umgestellt wird." + ::= { wtWebioAn8TimeZone 7 } + +wtWebioAn8StTzStartMode OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn8StartMode-first(1), + wtWebioAn8StartMode-second(2), + wtWebioAn8StartMode-third(3), + wtWebioAn8StartMode-fourth(4), + wtWebioAn8StartMode-last(5) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Modus des Wochentages, bei dem von Winterzeit auf Sommerzeit umgestellt wird." + ::= { wtWebioAn8TimeZone 8 } + +wtWebioAn8StTzStartWday OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn8StartWday-Sunday(1), + wtWebioAn8StartWday-Monday(2), + wtWebioAn8StartWday-Tuesday(3), + wtWebioAn8StartWday-Thursday(4), + wtWebioAn8StartWday-Wednesday(5), + wtWebioAn8StartWday-Friday(6), + wtWebioAn8StartWday-Saturday(7) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Wochentag, bei dem von Winterzeit auf Sommerzeit umgestellt wird" + ::= { wtWebioAn8TimeZone 9 } + +wtWebioAn8StTzStartHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Stunde, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebioAn8TimeZone 10 } + +wtWebioAn8StTzStartMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minute, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebioAn8TimeZone 11 } + +wtWebioAn8StTzStopMonth OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn8StopMonth-January(1), + wtWebioAn8StopMonth-February(2), + wtWebioAn8StopMonth-March(3), + wtWebioAn8StopMonth-April(4), + wtWebioAn8StopMonth-May(5), + wtWebioAn8StopMonth-June(6), + wtWebioAn8StopMonth-July(7), + wtWebioAn8StopMonth-August(8), + wtWebioAn8StopMonth-September(9), + wtWebioAn8StopMonth-October(10), + wtWebioAn8StopMonth-November(11), + wtWebioAn8StopMonth-December(12) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Monat, bei dem von Sommerzeit auf Winterzeit umgestellt wird." + ::= { wtWebioAn8TimeZone 12 } + +wtWebioAn8StTzStopMode OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn8StopMode-first(1), + wtWebioAn8StopMode-second(2), + wtWebioAn8StopMode-third(3), + wtWebioAn8StopMode-fourth(4), + wtWebioAn8StopMode-last(5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Modus des Wochentages, bei dem von Sommerzeit auf Winterzeit umgestellt wird." + ::= { wtWebioAn8TimeZone 13 } + +wtWebioAn8StTzStopWday OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn8StopWday-Sunday(1), + wtWebioAn8StopWday-Monday(2), + wtWebioAn8StopWday-Tuesday(3), + wtWebioAn8StopWday-Thursday(4), + wtWebioAn8StopWday-Wednesday(5), + wtWebioAn8StopWday-Friday(6), + wtWebioAn8StopWday-Saturday(7) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Wochentage, bei dem von Sommerzeit auf Winterzeit umgestellt wird." + ::= { wtWebioAn8TimeZone 14 } + +wtWebioAn8StTzStopHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Stunde, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebioAn8TimeZone 15 } + +wtWebioAn8StTzStopMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minute, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebioAn8TimeZone 16 } + +-- wtWebioAn8TimeServer Group +---------------------------- + +wtWebioAn8TimeServer1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse oder Name des 1. Time Servers in ASCII" + ::= { wtWebioAn8TimeServer 1 } + +wtWebioAn8TimeServer2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse oder Name des 2. Time Servers in ASCII" + ::= { wtWebioAn8TimeServer 2 } + +-- wtWebioAn8DeviceClock Group +---------------------------- + +wtWebioAn8ClockHrs OBJECT-TYPE + SYNTAX INTEGER (0..23) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Uhrzeit Stunde, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebioAn8DeviceClock 1 } + +wtWebioAn8ClockMin OBJECT-TYPE + SYNTAX INTEGER (0..59) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Uhrzeit Minute, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebioAn8DeviceClock 2 } + +wtWebioAn8ClockDay OBJECT-TYPE + SYNTAX INTEGER (1..31) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Datum: Tag des Monats, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebioAn8DeviceClock 3 } + +wtWebioAn8ClockMonth OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn8ClockMonth-January(1), + wtWebioAn8ClockMonth-February(2), + wtWebioAn8ClockMonth-March(3), + wtWebioAn8ClockMonth-April(4), + wtWebioAn8ClockMonth-May(5), + wtWebioAn8ClockMonth-June(6), + wtWebioAn8ClockMonth-July(7), + wtWebioAn8ClockMonth-August(8), + wtWebioAn8ClockMonth-September(9), + wtWebioAn8ClockMonth-October(10), + wtWebioAn8ClockMonth-November(11), + wtWebioAn8ClockMonth-December(12) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Datum: Monat, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebioAn8DeviceClock 4 } + +wtWebioAn8ClockYear OBJECT-TYPE + SYNTAX INTEGER (0..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Datum: Jahr, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebioAn8DeviceClock 5 } + +-- wtWebioAn8MailAdmin Group +-------------------------------- + +wtWebioAn8MailAdName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Gerätename für die Mail-Administration." + ::= { wtWebioAn8MailAdmin 1 } + +wtWebioAn8MailReply OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reply-Adresse für den Mailserver." + ::= { wtWebioAn8MailAdmin 2 } + +wtWebioAn8MailServer OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name oder Ip-Adresse des Mailservers." + ::= { wtWebioAn8MailAdmin 3 } + + +-- wtWebioAn8Alarm Group +---------------------------- + +wtWebioAn8AlarmCount OBJECT-TYPE + SYNTAX INTEGER (1..8) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Anzahl der unabhängigen Alarme." + ::= { wtWebioAn8Alarm 1 } + +-- Alarm Interface Table + +wtWebioAn8AlarmIfTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn8AlarmIfEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Alarmindizes." + ::= { wtWebioAn8Alarm 2 } + +wtWebioAn8AlarmIfEntry OBJECT-TYPE + SYNTAX WtWebioAn8AlarmIfEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Nummern der Alarme." + INDEX { wtWebioAn8AlarmNo } + ::= { wtWebioAn8AlarmIfTable 1 } + +WtWebioAn8AlarmIfEntry ::= SEQUENCE { + wtWebioAn8AlarmNo INTEGER (1..8) +} + +wtWebioAn8AlarmNo OBJECT-TYPE + SYNTAX INTEGER (1..8) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Nummer des Alarms." + ::= { wtWebioAn8AlarmIfEntry 1 } + +-- Alarm Table + +wtWebioAn8AlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn8AlarmEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Einstellungen abhängig von der Alarmnummer." + ::= { wtWebioAn8Alarm 3 } + +wtWebioAn8AlarmEntry OBJECT-TYPE + SYNTAX WtWebioAn8AlarmEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Alarm-Parameter der einzelnen Alarme." + INDEX { wtWebioAn8AlarmNo } + ::= { wtWebioAn8AlarmTable 1 } + +WtWebioAn8AlarmEntry ::= SEQUENCE { + wtWebioAn8AlarmTrigger OCTET STRING, + wtWebioAn8AlarmMin OCTET STRING, + wtWebioAn8AlarmMax OCTET STRING, + wtWebioAn8AlarmInterval OCTET STRING, + wtWebioAn8AlarmEnable OCTET STRING, + wtWebioAn8AlarmEMailAddr OCTET STRING, + wtWebioAn8AlarmMailSubject OCTET STRING, + wtWebioAn8AlarmMailText OCTET STRING, + wtWebioAn8AlarmManagerIP OCTET STRING, + wtWebioAn8AlarmTrapText OCTET STRING, + wtWebioAn8AlarmMailOptions OCTET STRING, + wtWebioAn8AlarmTcpIpAddr OCTET STRING, + wtWebioAn8AlarmTcpPort INTEGER, + wtWebioAn8AlarmTcpText OCTET STRING, + wtWebioAn8AlarmHysteresis OCTET STRING, + wtWebioAn8AlarmClearMailSubject OCTET STRING, + wtWebioAn8AlarmClearMailText OCTET STRING, + wtWebioAn8AlarmClearTrapText OCTET STRING, + wtWebioAn8AlarmClearTcpText OCTET STRING +} + +wtWebioAn8AlarmTrigger OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: + Bit 0: Timer + Bit 1: ColdStart + Bit 2: WarmStart + Octet 4: + Bit 0: Sensor 1 + Bit 1: Sensor 2 + Bit 2: Sensor 3 + Bit 3: Sensor 4 + Bit 4: Sensor 5 + Bit 5: Sensor 6 + Bit 6: Sensor 7 + Bit 7: Sensor 8" + ::= { wtWebioAn8AlarmEntry 1 } + +wtWebioAn8AlarmMin OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum Temperatur in Grad mit maximal 2 Nachkommastellen." + ::= { wtWebioAn8AlarmEntry 2 } + +wtWebioAn8AlarmMax OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum Temperatur in Grad mit maximal 2 Nachkommastellen." + ::= { wtWebioAn8AlarmEntry 3 } + +wtWebioAn8AlarmInterval OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sendeintervall von Alarmmeldungen." + ::= { wtWebioAn8AlarmEntry 4 } + +wtWebioAn8AlarmEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Alarmfreischaltung: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: Mail Enable + Bit 1: SNMP Trap enable + Bit 2: TCP Client enable" + ::= { wtWebioAn8AlarmEntry 5 } + +wtWebioAn8AlarmEMailAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "E-Mail Adresse, an die die Alarmmail gesendet werden soll." + ::= { wtWebioAn8AlarmEntry 6 } + +wtWebioAn8AlarmMailSubject OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Betreffzeile der Alarmmail." + ::= { wtWebioAn8AlarmEntry 7 } + +wtWebioAn8AlarmMailText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Text der Alarmmail: liefert die aktuelle Temperatur; n = 1..8. + liefert die aktuelle Zeit." + ::= { wtWebioAn8AlarmEntry 8 } + +wtWebioAn8AlarmManagerIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name oder IP-Adresse des SNMP-Managers, der den Trap entgegen nimmt." + ::= { wtWebioAn8AlarmEntry 9 } + +wtWebioAn8AlarmTrapText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im Trapbody gesendet." + ::= { wtWebioAn8AlarmEntry 10 } + +wtWebioAn8AlarmMailOptions OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Optionen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0 : Attach Thermo.csv Enable + Bit 1-7: ungenutzt" + ::= { wtWebioAn8AlarmEntry 11 } + +wtWebioAn8AlarmTcpIpAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des Gerätes, dass eine TCP-Nachricht empfangen soll." + ::= { wtWebioAn8AlarmEntry 12 } + +wtWebioAn8AlarmTcpPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Portnummer des Gerätes, dass eine TCP-Nachricht empfangen soll." + ::= { wtWebioAn8AlarmEntry 13 } + +wtWebioAn8AlarmTcpText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im TCP Trapbody gesendet." + ::= { wtWebioAn8AlarmEntry 14 } + +wtWebioAn8AlarmHysteresis OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bei Überschreiten der Temperatur Min+Hyst. und Unterschreiten der Temperatur Max-Hyst. + wird der Alarm gelöscht: pos. Temperaturdifferenz in Grad mit maximal 2 Nachkommastellen." + ::= { wtWebioAn8AlarmEntry 15 } + +wtWebioAn8AlarmClearMailSubject OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Betreffzeile der Alarm Clear Mail." + ::= { wtWebioAn8AlarmEntry 16 } + +wtWebioAn8AlarmClearMailText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Text der Alarm Clear Mail: liefert die aktuelle Temperatur; n = 1..8. + liefert die aktuelle Zeit." + ::= { wtWebioAn8AlarmEntry 17 } + +wtWebioAn8AlarmClearTrapText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im Trapbody gesendet." + ::= { wtWebioAn8AlarmEntry 18 } + +wtWebioAn8AlarmClearTcpText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im TCP Trapbody gesendet." + ::= { wtWebioAn8AlarmEntry 19 } + + +-- wtWebioAn8Datalogger Group +-------------------------------- + +wtWebioAn8LoggerTimebase OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn8Datalogger-1Min(1), + wtWebioAn8Datalogger-5Min(2), + wtWebioAn8Datalogger-15Min(3), + wtWebioAn8Datalogger-60Min(4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Zeitbasis des Dataloggers" + ::= { wtWebioAn8Datalogger 1 } + +wtWebioAn8LoggerSensorSel OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: Sensor 1 + Bit 1: Sensor 2 + Bit 2: Sensor 3 + Bit 3: Sensor 4 + Bit 4: Sensor 5 + Bit 5: Sensor 6 + Bit 6: Sensor 7 + Bit 7: Sensor 8" + ::= { wtWebioAn8Datalogger 2 } + +-- wtWebioAn8Protocol Group +---------------------------- + +wtWebioAn8PrtclUdpPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Udp Port, an den die Udp-Anfragen GET Single gesendet werden können" + ::= { wtWebioAn8PrtclUDP 1 } + +wtWebioAn8PrtclSnmpCommunityStringRead OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Community string read only" + ::= { wtWebioAn8PrtclSNMP 1 } + +wtWebioAn8PrtclSnmpCommunityStringReadWrite OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Community string read / write" + ::= { wtWebioAn8PrtclSNMP 2 } + +wtWebioAn8SystemTrapManagerIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name oder IP-Adresse des SNMP-Managers, der den System Trap entgegen nimmt." + ::= { wtWebioAn8PrtclSNMP 3 } + +wtWebioAn8SystemTrapEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: ColdStart + Bit 1: WarmStart + Bit 2-7: ungenutzt" + ::= { wtWebioAn8PrtclSNMP 4 } + +wtWebioAn8PrtclHttpPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "HTTP Port, an den die HTTP-Anfragen GET Single gesendet werden können" + ::= { wtWebioAn8PrtclHTTP 1 } + + +-- wtWebioAn8Enable Group +---------------------------- + +wtWebioAn8Enables OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: Update enable + Bit 1: Mail enable + Bit 2: Snmp enable + Bit 3: UDP enable + Bit 4: Get Singel Header enable + Bit 5: Apply Timezone + Bit 6: Apply Summertime + Bit 7: Apply TimeServer" + ::= { wtWebioAn8Enable 1 } + +-- wtWebioAn8Startup Group +---------------------------- + +wtWebioAn8StartupSite OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Startseite: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 1: Index.htm + Bit 2: Home.htm + Bit 3: User.htm + Es darf jeweils nur eine Seite ausgewählt sein." + ::= { wtWebioAn8Startup 1 } + +-- wtWebioAn8Ports Group +---------------------------- + +-- Table + +wtWebioAn8PortTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn8PortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Einstellungen abhängig von der Sensornummer." + ::= { wtWebioAn8Ports 1 } + +wtWebioAn8PortEntry OBJECT-TYPE + SYNTAX WtWebioAn8PortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Sensor-Parameter der einzelnen Sensoren." + INDEX { wtWebioAn8SensorNo } + ::= { wtWebioAn8PortTable 1 } + +WtWebioAn8PortEntry ::= SEQUENCE { + wtWebioAn8PortName OCTET STRING, + wtWebioAn8PortText OCTET STRING, + wtWebioAn8PortOffset1 OCTET STRING, + wtWebioAn8PortTemperature1 OCTET STRING, + wtWebioAn8PortOffset2 OCTET STRING, + wtWebioAn8PortTemperature2 OCTET STRING, + wtWebioAn8PortComment OCTET STRING +} + +wtWebioAn8PortName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name des Sensors." + ::= { wtWebioAn8PortEntry 1 } + +wtWebioAn8PortText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Beschreibung des Sensors." + ::= { wtWebioAn8PortEntry 2 } + +wtWebioAn8PortOffset1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 1." + ::= { wtWebioAn8PortEntry 3 } + +wtWebioAn8PortTemperature1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Referenztemperatur 1 in Grad mit max. 2 Nachkommastellen." + ::= { wtWebioAn8PortEntry 4 } + +wtWebioAn8PortOffset2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 2." + ::= { wtWebioAn8PortEntry 5 } + +wtWebioAn8PortTemperature2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Referenztemperatur 2 in Grad mit max. 2 Nachkommastellen." + ::= { wtWebioAn8PortEntry 6 } + +wtWebioAn8PortComment OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Angaben zu Datum, Referenzgerät, Operator." + ::= { wtWebioAn8PortEntry 7 } + +-- wtWebioAn8Manufact Group +---------------------------- + +wtWebioAn8MfName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Hersteller Firmenname" + ::= { wtWebioAn8Manufact 1 } + +wtWebioAn8MfAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Adresse des Herstellers." + ::= { wtWebioAn8Manufact 2 } + +wtWebioAn8MfHotline OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Hotline des Herstellers." + ::= { wtWebioAn8Manufact 3 } + +wtWebioAn8MfInternet OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Internet-Adresse des Herstellers." + ::= { wtWebioAn8Manufact 4 } + +wtWebioAn8MfDeviceTyp OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Gerätebezeichnung (Typ) des Herstellers." + ::= { wtWebioAn8Manufact 5 } + +wtWebioAn8MfOrderNo OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bestellnummer des Gerätes des Herstellers." + ::= { wtWebioAn8Manufact 6 } + + + +-- TRAP DEFINITIONS + +-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen + +wtWebioAn8Alert1 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 1" + --#SUMMARY "Alarm 1: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 11 + +wtWebioAn8Alert2 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 2" + --#SUMMARY "Alarm 2: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 12 + +wtWebioAn8Alert3 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 3" + --#SUMMARY "Alarm 3: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 13 + +wtWebioAn8Alert4 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 4" + --#SUMMARY "Alarm 4: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 14 + +wtWebioAn8Alert5 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 5" + --#SUMMARY "Alarm 5: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 15 + +wtWebioAn8Alert6 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 6" + --#SUMMARY "Alarm 6: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 16 + +wtWebioAn8Alert7 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 7" + --#SUMMARY "Alarm 7: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 17 + +wtWebioAn8Alert8 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 8" + --#SUMMARY "Alarm 8: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 18 + +wtWebioAn8Alert9 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 1" + --#SUMMARY "Alarm 1: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 71 + +wtWebioAn8Alert10 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 2" + --#SUMMARY "Alarm 2: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 72 + +wtWebioAn8Alert11 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 3" + --#SUMMARY "Alarm 3: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 73 + +wtWebioAn8Alert12 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 4" + --#SUMMARY "Alarm 4: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 74 + +wtWebioAn8Alert13 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 5" + --#SUMMARY "Alarm 5: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 75 + +wtWebioAn8Alert14 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 6" + --#SUMMARY "Alarm 6: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 76 + +wtWebioAn8Alert15 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 7" + --#SUMMARY "Alarm 7: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 77 + +wtWebioAn8Alert16 TRAP-TYPE + ENTERPRISE wtWebioAn8 + VARIABLES { wtWebioAn8AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 8" + --#SUMMARY "Alarm 8: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 78 + +-------------------------------------------------------------------------------- +-------------------------------------------------------------------------------- +-------------------------------------------------------------------------------- + +-- wtWebioAn2Temp Group +------------------------ + +wtWebioAn2Sensors OBJECT-TYPE + SYNTAX INTEGER (1..2) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Anzahl der Temperatursensoren" + ::= { wtWebioAn2Temp 1 } + +-- Interface Table + +wtWebioAn2SensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn2SensorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Sensoren." + ::= { wtWebioAn2Temp 2 } + +wtWebioAn2SensorEntry OBJECT-TYPE + SYNTAX WtWebioAn2SensorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Nummern der Temperatursensoren." + INDEX { wtWebioAn2SensorNo } + ::= { wtWebioAn2SensorTable 1 } + +WtWebioAn2SensorEntry ::= SEQUENCE { + wtWebioAn2SensorNo INTEGER (1..2) +} + +wtWebioAn2SensorNo OBJECT-TYPE + SYNTAX INTEGER (1..2) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Nummer des Temperatursensors." + ::= { wtWebioAn2SensorEntry 1 } + + +-- wtWebioAn2TempValue Table + +wtWebioAn2TempValueTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn2TempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste Temperaturwerte korrespondiernd zu den Kanalnummern." + ::= { wtWebioAn2Temp 3 } + +wtWebioAn2TempValueEntry OBJECT-TYPE + SYNTAX WtWebioAn2TempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Temperaturen der Sensoren." + INDEX { wtWebioAn2SensorNo } + ::= { wtWebioAn2TempValueTable 1 } + +WtWebioAn2TempValueEntry ::= SEQUENCE{ + wtWebioAn2TempValue OCTET STRING (SIZE (5)) +} + +wtWebioAn2TempValue OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (5)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Temperaturwert des Sensors, ASCII, 5 Zeichen lang." + ::= { wtWebioAn2TempValueEntry 1 } + +-- wtWebioAn2BinaryTempValue Table + +wtWebioAn2BinaryTempValueTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn2BinaryTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste binärer Temperaturwerte korrespondiernd zu den Kanalnummern." + ::= { wtWebioAn2Temp 4 } + +wtWebioAn2BinaryTempValueEntry OBJECT-TYPE + SYNTAX WtWebioAn2BinaryTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Binäre Temperaturen der Sensoren." + INDEX { wtWebioAn2SensorNo } + ::= { wtWebioAn2BinaryTempValueTable 1 } + +WtWebioAn2BinaryTempValueEntry ::= SEQUENCE{ + wtWebioAn2BinaryTempValue INTEGER +} + +wtWebioAn2BinaryTempValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Binärer Temperaturwert des Sensors in 1/10 Grad Celcius, + vorzeichenbehaftete Zahl, der Wert 0x7FFF zeigt einen + ungültigen Messwert an." + ::= { wtWebioAn2BinaryTempValueEntry 1 } + +-- wtWebioAn2SessCntrl Group +---------------------------- + +wtWebioAn2SessCntrlPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Durch Eintrag diese Passworts wird eine Session eröffnet, die durch Schreiben einer 1 + in wtWebioAn2SessCntrlLogout beendet wird. Gelesen liefert diese Variable einen String der + Länge Null." + ::= { wtWebioAn2SessCntrl 1 } + +wtWebioAn2SessCntrlConfigMode OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn2SessCntrl-NoSession(0), + wtWebioAn2SessCntrl-Session(1) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Wenn sich das Gerät im SNMP-Konfigurationsmodus befindet, wird der Wert + 1 zurückgeliefert, ansonsten 0. Ist der ausgelesene Wert 0 + obwohl das Passwort geschrieben wurde, befindet sich das Gerät bereits + im Configmodus und die Variablen können nur gelesen werden." + ::= { wtWebioAn2SessCntrl 2 } + +wtWebioAn2SessCntrlLogout OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Wenn sich das Gerät im Konfigurationsmodus befindet und die Session wurde + von diesem SNMP Manager eröffnet, kann durch Schreiben einer 1 in diese + Variable die Session beendet werden und alle Parameter werden gespeichert. + Durch Schreiben einer 2 werden alle Eingaben wieder verworfen. + Gelesen liefert diese Variable den Wert 0." + ::= { wtWebioAn2SessCntrl 3 } + +wtWebioAn2SessCntrlAdminPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieses Passwort schützt den Zugang der Variablen mit Administratorrechten. Es kann nur vom + Administrator verändert werden. Wurde kein Passwort vergeben so ist public das gültige Passwort. + Gelesen liefert diese Variable einen Null-Pointer." + ::= { wtWebioAn2SessCntrl 4 } + +wtWebioAn2SessCntrlConfigPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieses Passwort schützt den Zugang der Variablen mit Configuratorrechten. Es kann vom + Administrator und vom Configurator verändert werden. Wurde kein Passwort vergeben so ist + public das gültige Passwort.Gelesen liefert diese Variable einen Null-Pointer." + ::= { wtWebioAn2SessCntrl 5 } + + +-- wtWebioAn2Network Group +------------------------ + +wtWebioAn2IpAddress OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des Webio's" + ::= { wtWebioAn2Network 1 } + +wtWebioAn2SubnetMask OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Subnetmask des Webio's" + ::= { wtWebioAn2Network 2 } + +wtWebioAn2Gateway OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Gateway des Webio's" + ::= { wtWebioAn2Network 3 } + +wtWebioAn2DnsServer1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des 1. DNS Servers in ASCII" + ::= { wtWebioAn2Network 4 } + +wtWebioAn2DnsServer2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des 2. DNS Servers in ASCII" + ::= { wtWebioAn2Network 5 } + +wtWebioAn2AddConfig OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Zusatzkonfiguration (1=EIN): + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: BOOTP disable + " + ::= { wtWebioAn2Network 6 } + +-- wtWebioAn2Text Group +------------------------ + +wtWebioAn2DeviceName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name des Webio's, der userdefinierbar ist." + ::= { wtWebioAn2Text 1 } + +wtWebioAn2DeviceText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Beschreibung des Webio's, die userdefinierbar ist." + ::= { wtWebioAn2Text 2 } + +wtWebioAn2DeviceLocation OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Aufstellort des Webio's, die userdefinierbar ist." + ::= { wtWebioAn2Text 3 } + +wtWebioAn2DeviceContact OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Kontactadresse im Servicefall des Webio's, die userdefinierbar ist." + ::= { wtWebioAn2Text 4 } + +-- wtWebioAn2TimeZone Group +---------------------------- + +wtWebioAn2TzName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name der Zeitzone (Winterzeit)." + ::= { wtWebioAn2TimeZone 1 } + +wtWebioAn2TzOffsetHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Stunden der Zeitzone (Winterzeit) in Bezug auf UTC." + ::= { wtWebioAn2TimeZone 2 } + +wtWebioAn2TzOffsetMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Minuten der Zeitzone (Winterzeit) in Bezug auf UTC." + ::= { wtWebioAn2TimeZone 3 } + +wtWebioAn2StTzName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name der Zeitzone (Sommerzeit)." + ::= { wtWebioAn2TimeZone 4 } + +wtWebioAn2StTzOffsetHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Stunden der Zeitzone (Sommerzeit) in Bezug auf UTC." + ::= { wtWebioAn2TimeZone 5 } + +wtWebioAn2StTzOffsetMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Minuten der Zeitzone (Sommerzeit) in Bezug auf UTC." + ::= { wtWebioAn2TimeZone 6 } + +wtWebioAn2StTzStartMonth OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn2StartMonth-January(1), + wtWebioAn2StartMonth-February(2), + wtWebioAn2StartMonth-March(3), + wtWebioAn2StartMonth-April(4), + wtWebioAn2StartMonth-May(5), + wtWebioAn2StartMonth-June(6), + wtWebioAn2StartMonth-July(7), + wtWebioAn2StartMonth-August(8), + wtWebioAn2StartMonth-September(9), + wtWebioAn2StartMonth-October(10), + wtWebioAn2StartMonth-November(11), + wtWebioAn2StartMonth-December(12) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Monat, in dem von Winterzeit auf Sommerzeit umgestellt wird." + ::= { wtWebioAn2TimeZone 7 } + +wtWebioAn2StTzStartMode OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn2StartMode-first(1), + wtWebioAn2StartMode-second(2), + wtWebioAn2StartMode-third(3), + wtWebioAn2StartMode-fourth(4), + wtWebioAn2StartMode-last(5) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Modus des Wochentages, bei dem von Winterzeit auf Sommerzeit umgestellt wird." + ::= { wtWebioAn2TimeZone 8 } + +wtWebioAn2StTzStartWday OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn2StartWday-Sunday(1), + wtWebioAn2StartWday-Monday(2), + wtWebioAn2StartWday-Tuesday(3), + wtWebioAn2StartWday-Thursday(4), + wtWebioAn2StartWday-Wednesday(5), + wtWebioAn2StartWday-Friday(6), + wtWebioAn2StartWday-Saturday(7) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Wochentag, bei dem von Winterzeit auf Sommerzeit umgestellt wird" + ::= { wtWebioAn2TimeZone 9 } + +wtWebioAn2StTzStartHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Stunde, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebioAn2TimeZone 10 } + +wtWebioAn2StTzStartMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minute, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebioAn2TimeZone 11 } + +wtWebioAn2StTzStopMonth OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn2StopMonth-January(1), + wtWebioAn2StopMonth-February(2), + wtWebioAn2StopMonth-March(3), + wtWebioAn2StopMonth-April(4), + wtWebioAn2StopMonth-May(5), + wtWebioAn2StopMonth-June(6), + wtWebioAn2StopMonth-July(7), + wtWebioAn2StopMonth-August(8), + wtWebioAn2StopMonth-September(9), + wtWebioAn2StopMonth-October(10), + wtWebioAn2StopMonth-November(11), + wtWebioAn2StopMonth-December(12) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Monat, bei dem von Sommerzeit auf Winterzeit umgestellt wird." + ::= { wtWebioAn2TimeZone 12 } + +wtWebioAn2StTzStopMode OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn2StopMode-first(1), + wtWebioAn2StopMode-second(2), + wtWebioAn2StopMode-third(3), + wtWebioAn2StopMode-fourth(4), + wtWebioAn2StopMode-last(5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Modus des Wochentages, bei dem von Sommerzeit auf Winterzeit umgestellt wird." + ::= { wtWebioAn2TimeZone 13 } + +wtWebioAn2StTzStopWday OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn2StopWday-Sunday(1), + wtWebioAn2StopWday-Monday(2), + wtWebioAn2StopWday-Tuesday(3), + wtWebioAn2StopWday-Thursday(4), + wtWebioAn2StopWday-Wednesday(5), + wtWebioAn2StopWday-Friday(6), + wtWebioAn2StopWday-Saturday(7) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Wochentage, bei dem von Sommerzeit auf Winterzeit umgestellt wird." + ::= { wtWebioAn2TimeZone 14 } + +wtWebioAn2StTzStopHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Stunde, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebioAn2TimeZone 15 } + +wtWebioAn2StTzStopMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minute, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebioAn2TimeZone 16 } + +-- wtWebioAn2TimeServer Group +---------------------------- + +wtWebioAn2TimeServer1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse oder Name des 1. Time Servers in ASCII" + ::= { wtWebioAn2TimeServer 1 } + +wtWebioAn2TimeServer2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse oder Name des 2. Time Servers in ASCII" + ::= { wtWebioAn2TimeServer 2 } + +-- wtWebioAn2DeviceClock Group +---------------------------- + +wtWebioAn2ClockHrs OBJECT-TYPE + SYNTAX INTEGER (0..23) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Uhrzeit Stunde, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebioAn2DeviceClock 1 } + +wtWebioAn2ClockMin OBJECT-TYPE + SYNTAX INTEGER (0..59) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Uhrzeit Minute, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebioAn2DeviceClock 2 } + +wtWebioAn2ClockDay OBJECT-TYPE + SYNTAX INTEGER (1..31) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Datum: Tag des Monats, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebioAn2DeviceClock 3 } + +wtWebioAn2ClockMonth OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn2ClockMonth-January(1), + wtWebioAn2ClockMonth-February(2), + wtWebioAn2ClockMonth-March(3), + wtWebioAn2ClockMonth-April(4), + wtWebioAn2ClockMonth-May(5), + wtWebioAn2ClockMonth-June(6), + wtWebioAn2ClockMonth-July(7), + wtWebioAn2ClockMonth-August(8), + wtWebioAn2ClockMonth-September(9), + wtWebioAn2ClockMonth-October(10), + wtWebioAn2ClockMonth-November(11), + wtWebioAn2ClockMonth-December(12) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Datum: Monat, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebioAn2DeviceClock 4 } + +wtWebioAn2ClockYear OBJECT-TYPE + SYNTAX INTEGER (0..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Datum: Jahr, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebioAn2DeviceClock 5 } + +-- wtWebioAn2MailAdmin Group +---------------------------- + +wtWebioAn2MailAdName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Gerätename für die Mail-Administration." + ::= { wtWebioAn2MailAdmin 1 } + +wtWebioAn2MailReply OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reply-Adresse für den Mailserver." + ::= { wtWebioAn2MailAdmin 2 } + +wtWebioAn2MailServer OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name oder Ip-Adresse des Mailservers." + ::= { wtWebioAn2MailAdmin 3 } + + +-- wtWebioAn2Alarm Group +---------------------------- + +wtWebioAn2AlarmCount OBJECT-TYPE + SYNTAX INTEGER (1..8) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Anzahl der unabhängigen Alarme." + ::= { wtWebioAn2Alarm 1 } + +-- Alarm Interface Table + +wtWebioAn2AlarmIfTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn2AlarmIfEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Alarmindizes." + ::= { wtWebioAn2Alarm 2 } + +wtWebioAn2AlarmIfEntry OBJECT-TYPE + SYNTAX WtWebioAn2AlarmIfEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Nummern der Alarme." + INDEX { wtWebioAn2AlarmNo } + ::= { wtWebioAn2AlarmIfTable 1 } + +WtWebioAn2AlarmIfEntry ::= SEQUENCE { + wtWebioAn2AlarmNo INTEGER (1..8) +} + +wtWebioAn2AlarmNo OBJECT-TYPE + SYNTAX INTEGER (1..8) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Nummer des Alarms." + ::= { wtWebioAn2AlarmIfEntry 1 } + +-- Alarm Table + +wtWebioAn2AlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn2AlarmEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Einstellungen abhängig von der Alarmnummer." + ::= { wtWebioAn2Alarm 3 } + +wtWebioAn2AlarmEntry OBJECT-TYPE + SYNTAX WtWebioAn2AlarmEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Alarm-Parameter der einzelnen Alarme." + INDEX { wtWebioAn2AlarmNo } + ::= { wtWebioAn2AlarmTable 1 } + +WtWebioAn2AlarmEntry ::= SEQUENCE { + wtWebioAn2AlarmTrigger OCTET STRING, + wtWebioAn2AlarmMin OCTET STRING, + wtWebioAn2AlarmMax OCTET STRING, + wtWebioAn2AlarmInterval OCTET STRING, + wtWebioAn2AlarmEnable OCTET STRING, + wtWebioAn2AlarmEMailAddr OCTET STRING, + wtWebioAn2AlarmMailSubject OCTET STRING, + wtWebioAn2AlarmMailText OCTET STRING, + wtWebioAn2AlarmManagerIP OCTET STRING, + wtWebioAn2AlarmTrapText OCTET STRING, + wtWebioAn2AlarmMailOptions OCTET STRING, + wtWebioAn2AlarmTcpIpAddr OCTET STRING, + wtWebioAn2AlarmTcpPort INTEGER, + wtWebioAn2AlarmTcpText OCTET STRING, + wtWebioAn2AlarmHysteresis OCTET STRING, + wtWebioAn2AlarmClearMailSubject OCTET STRING, + wtWebioAn2AlarmClearMailText OCTET STRING, + wtWebioAn2AlarmClearTrapText OCTET STRING, + wtWebioAn2AlarmClearTcpText OCTET STRING +} + +wtWebioAn2AlarmTrigger OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: Sensor 1 + Bit 1: Sensor 2 + Bit 2: Timer + Bit 3: ColdStart + Bit 4: WarmStart" + ::= { wtWebioAn2AlarmEntry 1 } + +wtWebioAn2AlarmMin OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum Temperatur in Grad mit maximal 2 Nachkommastellen." + ::= { wtWebioAn2AlarmEntry 2 } + +wtWebioAn2AlarmMax OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum Temperatur in Grad mit maximal 2 Nachkommastellen." + ::= { wtWebioAn2AlarmEntry 3 } + +wtWebioAn2AlarmInterval OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sendeintervall von Alarmmeldungen." + ::= { wtWebioAn2AlarmEntry 4 } + +wtWebioAn2AlarmEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Alarmfreischaltung: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: Mail Enable + Bit 1: SNMP Trap enable + Bit 2: TCP Client enable" + ::= { wtWebioAn2AlarmEntry 5 } + +wtWebioAn2AlarmEMailAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "E-Mail Adresse, an die die Alarmmail gesendet werden soll." + ::= { wtWebioAn2AlarmEntry 6 } + +wtWebioAn2AlarmMailSubject OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Betreffzeile der Alarmmail." + ::= { wtWebioAn2AlarmEntry 7 } + +wtWebioAn2AlarmMailText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Text der Alarmmail: liefert die aktuelle Temperatur; n = 1..2. + liefert die aktuelle Zeit." + ::= { wtWebioAn2AlarmEntry 8 } + +wtWebioAn2AlarmManagerIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name oder IP-Adresse des SNMP-Managers, der den Trap entgegen nimmt." + ::= { wtWebioAn2AlarmEntry 9 } + +wtWebioAn2AlarmTrapText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im Trapbody gesendet." + ::= { wtWebioAn2AlarmEntry 10 } + +wtWebioAn2AlarmMailOptions OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Optionen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0 : Attach Thermo.csv Enable + Bit 1-7: ungenutzt" + ::= { wtWebioAn2AlarmEntry 11 } + +wtWebioAn2AlarmTcpIpAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des Gerätes, dass eine TCP-Nachricht empfangen soll." + ::= { wtWebioAn2AlarmEntry 12 } + +wtWebioAn2AlarmTcpPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Portnummer des Gerätes, dass eine TCP-Nachricht empfangen soll." + ::= { wtWebioAn2AlarmEntry 13 } + +wtWebioAn2AlarmTcpText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im TCP Trapbody gesendet." + ::= { wtWebioAn2AlarmEntry 14 } + +wtWebioAn2AlarmHysteresis OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bei Überschreiten der Temperatur Min+Hyst. und Unterschreiten der Temperatur Max-Hyst. + wird der Alarm gelöscht: pos. Temperaturdifferenz in Grad mit maximal 2 Nachkommastellen." + ::= { wtWebioAn2AlarmEntry 15 } + +wtWebioAn2AlarmClearMailSubject OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Betreffzeile der Alarm Clear Mail." + ::= { wtWebioAn2AlarmEntry 16 } + +wtWebioAn2AlarmClearMailText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Text der Alarm Clear Mail: liefert die aktuelle Temperatur; n = 1..8. + liefert die aktuelle Zeit." + ::= { wtWebioAn2AlarmEntry 17 } + +wtWebioAn2AlarmClearTrapText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im Trapbody gesendet." + ::= { wtWebioAn2AlarmEntry 18 } + +wtWebioAn2AlarmClearTcpText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im TCP Trapbody gesendet." + ::= { wtWebioAn2AlarmEntry 19 } + +-- wtWebioAn2Datalogger Group +-------------------------------- + +wtWebioAn2LoggerTimebase OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn2Datalogger-1Min(1), + wtWebioAn2Datalogger-5Min(2), + wtWebioAn2Datalogger-15Min(3), + wtWebioAn2Datalogger-60Min(4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Zeitbasis des Dataloggers" + ::= { wtWebioAn2Datalogger 1 } + +wtWebioAn2LoggerSensorSel OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: Sensor 1 + Bit 1: Sensor 2" + ::= { wtWebioAn2Datalogger 2 } + +-- wtWebioAn2Protocol Group +---------------------------- + +wtWebioAn2PrtclUdpPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Udp Port, an den die Udp-Anfragen GET Single gesendet werden können" + ::= { wtWebioAn2PrtclUDP 1 } + + +wtWebioAn2PrtclSnmpCommunityStringRead OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Community string read only" + ::= { wtWebioAn2PrtclSNMP 1 } + +wtWebioAn2PrtclSnmpCommunityStringReadWrite OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Community string read / write" + ::= { wtWebioAn2PrtclSNMP 2 } + +wtWebioAn2SystemTrapManagerIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name oder IP-Adresse des SNMP-Managers, der den System Trap entgegen nimmt." + ::= { wtWebioAn2PrtclSNMP 3 } + +wtWebioAn2SystemTrapEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: ColdStart + Bit 1: WarmStart + Bit 2-7: ungenutzt" + ::= { wtWebioAn2PrtclSNMP 4 } + +wtWebioAn2PrtclHttpPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "HTTP Port, an den die HTTP-Anfragen GET Single gesendet werden können" + ::= { wtWebioAn2PrtclHTTP 1 } + + +-- wtWebioAn2Enable Group +---------------------------- + +wtWebioAn2Enables OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: Update enable + Bit 1: Mail enable + Bit 2: Snmp enable + Bit 3: UDP enable + Bit 4: Get Single Header enable + Bit 5: Apply Timezone + Bit 6: Apply Summertime + Bit 7: Apply TimeServer" + ::= { wtWebioAn2Enable 1 } + +-- wtWebioAn2Startup Group +---------------------------- + +wtWebioAn2StartupSite OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Startseite: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 1: Index.htm + Bit 2: Home.htm + Bit 3: User.htm + Es darf jeweils nur eine Seite ausgewählt sein." + ::= { wtWebioAn2Startup 1 } + +-- wtWebioAn2Ports Group +---------------------------- + +-- Table + +wtWebioAn2PortTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn2PortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Einstellungen abhängig von der Sensornummer." + ::= { wtWebioAn2Ports 1 } + +wtWebioAn2PortEntry OBJECT-TYPE + SYNTAX WtWebioAn2PortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Sensor-Parameter der einzelnen Sensoren." + INDEX { wtWebioAn2SensorNo } + ::= { wtWebioAn2PortTable 1 } + +WtWebioAn2PortEntry ::= SEQUENCE { + wtWebioAn2PortName OCTET STRING, + wtWebioAn2PortText OCTET STRING, + wtWebioAn2PortOffset1 OCTET STRING, + wtWebioAn2PortTemperature1 OCTET STRING, + wtWebioAn2PortOffset2 OCTET STRING, + wtWebioAn2PortTemperature2 OCTET STRING, + wtWebioAn2PortComment OCTET STRING +} + +wtWebioAn2PortName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name des Sensors." + ::= { wtWebioAn2PortEntry 1 } + +wtWebioAn2PortText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Beschreibung des Sensors." + ::= { wtWebioAn2PortEntry 2 } + +wtWebioAn2PortOffset1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 1." + ::= { wtWebioAn2PortEntry 3 } + +wtWebioAn2PortTemperature1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Referenztemperatur 1 in Grad mit max. 2 Nachkommastellen." + ::= { wtWebioAn2PortEntry 4 } + +wtWebioAn2PortOffset2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 2." + ::= { wtWebioAn2PortEntry 5 } + +wtWebioAn2PortTemperature2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Referenztemperatur 2 in Grad mit max. 2 Nachkommastellen." + ::= { wtWebioAn2PortEntry 6 } + +wtWebioAn2PortComment OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Angaben zu Datum, Referenzgerät, Operator." + ::= { wtWebioAn2PortEntry 7 } + + +-- wtWebioAn2Manufact Group +---------------------------- + +wtWebioAn2MfName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Hersteller Firmenname" + ::= { wtWebioAn2Manufact 1 } + +wtWebioAn2MfAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Adresse des Herstellers." + ::= { wtWebioAn2Manufact 2 } + +wtWebioAn2MfHotline OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Hotline des Herstellers." + ::= { wtWebioAn2Manufact 3 } + +wtWebioAn2MfInternet OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Internet-Adresse des Herstellers." + ::= { wtWebioAn2Manufact 4 } + +wtWebioAn2MfDeviceTyp OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Gerätebezeichnung (Typ) des Herstellers." + ::= { wtWebioAn2Manufact 5 } + +wtWebioAn2MfOrderNo OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bestellnummer des Gerätes des Herstellers." + ::= { wtWebioAn2Manufact 6 } + +-- TRAP DEFINITIONS + +-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen + +wtWebioAn2Alert1 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 1" + --#SUMMARY "Alarm 1: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 21 + +wtWebioAn2Alert2 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 2" + --#SUMMARY "Alarm 2: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 22 + +wtWebioAn2Alert3 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 3" + --#SUMMARY "Alarm 3: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 23 + +wtWebioAn2Alert4 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 4" + --#SUMMARY "Alarm 4: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 24 + +wtWebioAn2Alert5 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 5" + --#SUMMARY "Alarm 5: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 25 + +wtWebioAn2Alert6 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 6" + --#SUMMARY "Alarm 6: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 26 + +wtWebioAn2Alert7 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 7" + --#SUMMARY "Alarm 7: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 27 + +wtWebioAn2Alert8 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 8" + --#SUMMARY "Alarm 8: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 28 + +wtWebioAn2Alert9 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 1" + --#SUMMARY "Alarm 1: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 81 + +wtWebioAn2Alert10 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 2" + --#SUMMARY "Alarm 2: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 82 + +wtWebioAn2Alert11 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 3" + --#SUMMARY "Alarm 3: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 83 + +wtWebioAn2Alert12 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 4" + --#SUMMARY "Alarm 4: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 84 + +wtWebioAn2Alert13 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 5" + --#SUMMARY "Alarm 5 %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 85 + +wtWebioAn2Alert14 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 6" + --#SUMMARY "Alarm 6: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 86 + +wtWebioAn2Alert15 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 7" + --#SUMMARY "Alarm 7: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 87 + +wtWebioAn2Alert16 TRAP-TYPE + ENTERPRISE wtWebioAn2 + VARIABLES { wtWebioAn2AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 8" + --#SUMMARY "Alarm 8: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 88 + +-------------------------------------------------------------------------------- +-------------------------------------------------------------------------------- +-------------------------------------------------------------------------------- + +-- wtWebioAn1Temp Group +------------------------ + +wtWebioAn1Sensors OBJECT-TYPE + SYNTAX INTEGER (1..8) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Anzahl der Temperatursensoren" + ::= { wtWebioAn1Temp 1 } + +-- Interface Table + +wtWebioAn1SensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn1SensorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Sensoren." + ::= { wtWebioAn1Temp 2 } + +wtWebioAn1SensorEntry OBJECT-TYPE + SYNTAX WtWebioAn1SensorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Nummern der Temperatursensoren." + INDEX { wtWebioAn1SensorNo } + ::= { wtWebioAn1SensorTable 1 } + +WtWebioAn1SensorEntry ::= SEQUENCE { + wtWebioAn1SensorNo INTEGER (1) +} + +wtWebioAn1SensorNo OBJECT-TYPE + SYNTAX INTEGER (1) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Nummer des Temperatursensors." + ::= { wtWebioAn1SensorEntry 1 } + + +-- wtWebioAn1TempValue Table + +wtWebioAn1TempValueTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn1TempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste Temperaturwerte korrespondiernd zu den Kanalnummern." + ::= { wtWebioAn1Temp 3 } + +wtWebioAn1TempValueEntry OBJECT-TYPE + SYNTAX WtWebioAn1TempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Temperaturen der Sensoren." + INDEX { wtWebioAn1SensorNo } + ::= { wtWebioAn1TempValueTable 1 } + +WtWebioAn1TempValueEntry ::= SEQUENCE{ + wtWebioAn1TempValue OCTET STRING (SIZE (5)) +} + +wtWebioAn1TempValue OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (5)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Temperaturwert des Sensors, ASCII, 5 Zeichen lang." + ::= { wtWebioAn1TempValueEntry 1 } + +-- wtWebioAn1BinaryTempValue Table + +wtWebioAn1BinaryTempValueTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn1BinaryTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste binärer Temperaturwerte korrespondiernd zu den Kanalnummern." + ::= { wtWebioAn1Temp 4 } + +wtWebioAn1BinaryTempValueEntry OBJECT-TYPE + SYNTAX WtWebioAn1BinaryTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Binäre Temperaturen der Sensoren." + INDEX { wtWebioAn1SensorNo } + ::= { wtWebioAn1BinaryTempValueTable 1 } + +WtWebioAn1BinaryTempValueEntry ::= SEQUENCE{ + wtWebioAn1BinaryTempValue INTEGER +} + +wtWebioAn1BinaryTempValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Binärer Temperaturwert des Sensors in 1/10 Grad Celcius, + vorzeichenbehaftete Zahl, der Wert 0x7FFF zeigt einen + ungültigen Messwert an." + ::= { wtWebioAn1BinaryTempValueEntry 1 } + +-- wtWebioAn1DeltaTempValue Table + +wtWebioAn1DeltaTempValueTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn1DeltaTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste Delta-Temperaturwerte korrespondiernd zu den Kanalnummern." + ::= { wtWebioAn1Temp 5 } + +wtWebioAn1DeltaTempValueEntry OBJECT-TYPE + SYNTAX WtWebioAn1DeltaTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Temperaturen der Sensoren." + INDEX { wtWebioAn1SensorNo } + ::= { wtWebioAn1DeltaTempValueTable 1 } + +WtWebioAn1DeltaTempValueEntry ::= SEQUENCE{ + wtWebioAn1DeltaTempValue OCTET STRING (SIZE (5)) +} + +wtWebioAn1DeltaTempValue OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (5)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Delta-Temperaturwert des Sensors, ASCII, 5 Zeichen lang." + ::= { wtWebioAn1DeltaTempValueEntry 1 } + +-- wtWebioAn1BinaryTempValue Table + +wtWebioAn1BinaryDeltaTempValueTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn1BinaryTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste binärer Temperaturwerte korrespondiernd zu den Kanalnummern." + ::= { wtWebioAn1Temp 6 } + +wtWebioAn1BinaryDeltaTempValueEntry OBJECT-TYPE + SYNTAX WtWebioAn1BinaryDeltaTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Binäre Temperaturen der Sensoren." + INDEX { wtWebioAn1SensorNo } + ::= { wtWebioAn1BinaryDeltaTempValueTable 1 } + +WtWebioAn1BinaryDeltaTempValueEntry ::= SEQUENCE{ + wtWebioAn1BinaryDeltaTempValue INTEGER +} + +wtWebioAn1BinaryDeltaTempValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Binärer Delta-Temperaturwert des Sensors in 1/10 Grad Celcius, + vorzeichenbehaftete Zahl, der Wert 0x7FFF zeigt einen + ungültigen Messwert an." + ::= { wtWebioAn1BinaryDeltaTempValueEntry 1 } + +-- wtWebioAn1SessCntrl Group +-------------------------------- + +wtWebioAn1SessCntrlPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Durch Eintrag diese Passworts wird eine Session eröffnet, die durch Schreiben einer 1 + in wtWebioAn1SessCntrlLogout beendet wird. Gelesen liefert diese Variable einen String der + Länge Null." + ::= { wtWebioAn1SessCntrl 1 } + +wtWebioAn1SessCntrlConfigMode OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn1SessCntrl-NoSession(0), + wtWebioAn1SessCntrl-Session(1) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Wenn sich das Gerät im SNMP-Konfigurationsmodus befindet, wird der Wert + 1 zurückgeliefert, ansonsten 0. Ist der ausgelesene Wert 0 + obwohl das Passwort geschrieben wurde, befindet sich das Gerät bereits + im Configmodus und die Variablen können nur gelesen werden." + ::= { wtWebioAn1SessCntrl 2 } + +wtWebioAn1SessCntrlLogout OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Wenn sich das Gerät im Konfigurationsmodus befindet und die Session wurde + von diesem SNMP Manager eröffnet, kann durch Schreiben einer 1 in diese + Variable die Session beendet werden und alle Parameter werden gespeichert. + Durch Schreiben einer 2 werden alle Eingaben wieder verworfen. + Gelesen liefert diese Variable den Wert 0." + ::= { wtWebioAn1SessCntrl 3 } + +wtWebioAn1SessCntrlAdminPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieses Passwort schützt den Zugang der Variablen mit Administratorrechten. Es kann nur vom + Administrator verändert werden. Wurde kein Passwort vergeben so ist public das gültige Passwort. + Gelesen liefert diese Variable einen Null-Pointer." + ::= { wtWebioAn1SessCntrl 4 } + +wtWebioAn1SessCntrlConfigPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieses Passwort schützt den Zugang der Variablen mit Configuratorrechten. Es kann vom + Administrator und vom Configurator verändert werden. Wurde kein Passwort vergeben so ist + public das gültige Passwort.Gelesen liefert diese Variable einen Null-Pointer." + ::= { wtWebioAn1SessCntrl 5 } + + +-- wtWebioAn1Network Group +------------------------ + +wtWebioAn1IpAddress OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des Webio's" + ::= { wtWebioAn1Network 1 } + +wtWebioAn1SubnetMask OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Subnetmask des Webio's" + ::= { wtWebioAn1Network 2 } + +wtWebioAn1Gateway OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Gateway des Webio's" + ::= { wtWebioAn1Network 3 } + +wtWebioAn1DnsServer1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des 1. DNS Servers in ASCII" + ::= { wtWebioAn1Network 4 } + +wtWebioAn1DnsServer2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des 2. DNS Servers in ASCII" + ::= { wtWebioAn1Network 5 } + +wtWebioAn1AddConfig OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Zusatzkonfiguration (1=EIN): + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: BOOTP disable + " + ::= { wtWebioAn1Network 6 } + +-- wtWebioAn1Text Group +------------------------ + +wtWebioAn1DeviceName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name des Webio's, der userdefinierbar ist." + ::= { wtWebioAn1Text 1 } + +wtWebioAn1DeviceText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Beschreibung des Webio's, die userdefinierbar ist." + ::= { wtWebioAn1Text 2 } + +wtWebioAn1DeviceLocation OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Aufstellort des Webio's, die userdefinierbar ist." + ::= { wtWebioAn1Text 3 } + +wtWebioAn1DeviceContact OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Kontactadresse im Servicefall des Webio's, die userdefinierbar ist." + ::= { wtWebioAn1Text 4 } + +-- wtWebioAn1TimeZone Group +---------------------------- + +wtWebioAn1TzName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name der Zeitzone (Winterzeit)." + ::= { wtWebioAn1TimeZone 1 } + +wtWebioAn1TzOffsetHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Stunden der Zeitzone (Winterzeit) in Bezug auf UTC." + ::= { wtWebioAn1TimeZone 2 } + +wtWebioAn1TzOffsetMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Minuten der Zeitzone (Winterzeit) in Bezug auf UTC." + ::= { wtWebioAn1TimeZone 3 } + +wtWebioAn1StTzName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name der Zeitzone (Sommerzeit)." + ::= { wtWebioAn1TimeZone 4 } + +wtWebioAn1StTzOffsetHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Stunden der Zeitzone (Sommerzeit) in Bezug auf UTC." + ::= { wtWebioAn1TimeZone 5 } + +wtWebioAn1StTzOffsetMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Minuten der Zeitzone (Sommerzeit) in Bezug auf UTC." + ::= { wtWebioAn1TimeZone 6 } + +wtWebioAn1StTzStartMonth OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn1StartMonth-January(1), + wtWebioAn1StartMonth-February(2), + wtWebioAn1StartMonth-March(3), + wtWebioAn1StartMonth-April(4), + wtWebioAn1StartMonth-May(5), + wtWebioAn1StartMonth-June(6), + wtWebioAn1StartMonth-July(7), + wtWebioAn1StartMonth-August(8), + wtWebioAn1StartMonth-September(9), + wtWebioAn1StartMonth-October(10), + wtWebioAn1StartMonth-November(11), + wtWebioAn1StartMonth-December(12) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Monat, in dem von Winterzeit auf Sommerzeit umgestellt wird." + ::= { wtWebioAn1TimeZone 7 } + +wtWebioAn1StTzStartMode OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn1StartMode-first(1), + wtWebioAn1StartMode-second(2), + wtWebioAn1StartMode-third(3), + wtWebioAn1StartMode-fourth(4), + wtWebioAn1StartMode-last(5) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Modus des Wochentages, bei dem von Winterzeit auf Sommerzeit umgestellt wird." + ::= { wtWebioAn1TimeZone 8 } + +wtWebioAn1StTzStartWday OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn1StartWday-Sunday(1), + wtWebioAn1StartWday-Monday(2), + wtWebioAn1StartWday-Tuesday(3), + wtWebioAn1StartWday-Thursday(4), + wtWebioAn1StartWday-Wednesday(5), + wtWebioAn1StartWday-Friday(6), + wtWebioAn1StartWday-Saturday(7) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Wochentag, bei dem von Winterzeit auf Sommerzeit umgestellt wird" + ::= { wtWebioAn1TimeZone 9 } + +wtWebioAn1StTzStartHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Stunde, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebioAn1TimeZone 10 } + +wtWebioAn1StTzStartMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minute, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebioAn1TimeZone 11 } + +wtWebioAn1StTzStopMonth OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn1StopMonth-January(1), + wtWebioAn1StopMonth-February(2), + wtWebioAn1StopMonth-March(3), + wtWebioAn1StopMonth-April(4), + wtWebioAn1StopMonth-May(5), + wtWebioAn1StopMonth-June(6), + wtWebioAn1StopMonth-July(7), + wtWebioAn1StopMonth-August(8), + wtWebioAn1StopMonth-September(9), + wtWebioAn1StopMonth-October(10), + wtWebioAn1StopMonth-November(11), + wtWebioAn1StopMonth-December(12) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Monat, bei dem von Sommerzeit auf Winterzeit umgestellt wird." + ::= { wtWebioAn1TimeZone 12 } + +wtWebioAn1StTzStopMode OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn1StopMode-first(1), + wtWebioAn1StopMode-second(2), + wtWebioAn1StopMode-third(3), + wtWebioAn1StopMode-fourth(4), + wtWebioAn1StopMode-last(5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Modus des Wochentages, bei dem von Sommerzeit auf Winterzeit umgestellt wird." + ::= { wtWebioAn1TimeZone 13 } + +wtWebioAn1StTzStopWday OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn1StopWday-Sunday(1), + wtWebioAn1StopWday-Monday(2), + wtWebioAn1StopWday-Tuesday(3), + wtWebioAn1StopWday-Thursday(4), + wtWebioAn1StopWday-Wednesday(5), + wtWebioAn1StopWday-Friday(6), + wtWebioAn1StopWday-Saturday(7) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Wochentage, bei dem von Sommerzeit auf Winterzeit umgestellt wird." + ::= { wtWebioAn1TimeZone 14 } + +wtWebioAn1StTzStopHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Stunde, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebioAn1TimeZone 15 } + +wtWebioAn1StTzStopMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minute, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebioAn1TimeZone 16 } + +-- wtWebioAn1TimeServer Group +---------------------------- + +wtWebioAn1TimeServer1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse oder Name des 1. Time Servers in ASCII" + ::= { wtWebioAn1TimeServer 1 } + +wtWebioAn1TimeServer2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse oder Name des 2. Time Servers in ASCII" + ::= { wtWebioAn1TimeServer 2 } + +-- wtWebioAn1DeviceClock Group +---------------------------- + +wtWebioAn1ClockHrs OBJECT-TYPE + SYNTAX INTEGER (0..23) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Uhrzeit Stunde, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebioAn1DeviceClock 1 } + +wtWebioAn1ClockMin OBJECT-TYPE + SYNTAX INTEGER (0..59) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Uhrzeit Minute, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebioAn1DeviceClock 2 } + +wtWebioAn1ClockDay OBJECT-TYPE + SYNTAX INTEGER (1..31) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Datum: Tag des Monats, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebioAn1DeviceClock 3 } + +wtWebioAn1ClockMonth OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn1ClockMonth-January(1), + wtWebioAn1ClockMonth-February(2), + wtWebioAn1ClockMonth-March(3), + wtWebioAn1ClockMonth-April(4), + wtWebioAn1ClockMonth-May(5), + wtWebioAn1ClockMonth-June(6), + wtWebioAn1ClockMonth-July(7), + wtWebioAn1ClockMonth-August(8), + wtWebioAn1ClockMonth-September(9), + wtWebioAn1ClockMonth-October(10), + wtWebioAn1ClockMonth-November(11), + wtWebioAn1ClockMonth-December(12) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Datum: Monat, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebioAn1DeviceClock 4 } + +wtWebioAn1ClockYear OBJECT-TYPE + SYNTAX INTEGER (0..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Datum: Jahr, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebioAn1DeviceClock 5 } + +-- wtWebioAn1MailAdmin Group +-------------------------------- + +wtWebioAn1MailAdName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Gerätename für die Mail-Administration." + ::= { wtWebioAn1MailAdmin 1 } + +wtWebioAn1MailReply OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reply-Adresse für den Mailserver." + ::= { wtWebioAn1MailAdmin 2 } + +wtWebioAn1MailServer OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name oder Ip-Adresse des Mailservers." + ::= { wtWebioAn1MailAdmin 3 } + + +-- wtWebioAn1Alarm Group +---------------------------- + +wtWebioAn1AlarmCount OBJECT-TYPE + SYNTAX INTEGER (1..8) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Anzahl der unabhängigen Alarme." + ::= { wtWebioAn1Alarm 1 } + +-- Alarm Interface Table + +wtWebioAn1AlarmIfTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn1AlarmIfEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Alarmindizes." + ::= { wtWebioAn1Alarm 2 } + +wtWebioAn1AlarmIfEntry OBJECT-TYPE + SYNTAX WtWebioAn1AlarmIfEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Nummern der Alarme." + INDEX { wtWebioAn1AlarmNo } + ::= { wtWebioAn1AlarmIfTable 1 } + +WtWebioAn1AlarmIfEntry ::= SEQUENCE { + wtWebioAn1AlarmNo INTEGER (1..8) +} + +wtWebioAn1AlarmNo OBJECT-TYPE + SYNTAX INTEGER (1..8) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Nummer des Alarms." + ::= { wtWebioAn1AlarmIfEntry 1 } + +-- Alarm Table + +wtWebioAn1AlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn1AlarmEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Einstellungen abhängig von der Alarmnummer." + ::= { wtWebioAn1Alarm 3 } + +wtWebioAn1AlarmEntry OBJECT-TYPE + SYNTAX WtWebioAn1AlarmEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Alarm-Parameter der einzelnen Alarme." + INDEX { wtWebioAn1AlarmNo } + ::= { wtWebioAn1AlarmTable 1 } + +WtWebioAn1AlarmEntry ::= SEQUENCE { + wtWebioAn1AlarmTrigger OCTET STRING, + wtWebioAn1AlarmMin OCTET STRING, + wtWebioAn1AlarmMax OCTET STRING, + wtWebioAn1AlarmInterval OCTET STRING, + wtWebioAn1AlarmEnable OCTET STRING, + wtWebioAn1AlarmEMailAddr OCTET STRING, + wtWebioAn1AlarmMailSubject OCTET STRING, + wtWebioAn1AlarmMailText OCTET STRING, + wtWebioAn1AlarmManagerIP OCTET STRING, + wtWebioAn1AlarmTrapText OCTET STRING, + wtWebioAn1AlarmMailOptions OCTET STRING, + wtWebioAn1AlarmTcpIpAddr OCTET STRING, + wtWebioAn1AlarmTcpPort INTEGER, + wtWebioAn1AlarmTcpText OCTET STRING, + wtWebioAn1AlarmHysteresis OCTET STRING, + wtWebioAn1AlarmClearMailSubject OCTET STRING, + wtWebioAn1AlarmClearMailText OCTET STRING, + wtWebioAn1AlarmClearTrapText OCTET STRING, + wtWebioAn1AlarmClearTcpText OCTET STRING, + wtWebioAn1AlarmDeltaTemp OCTET STRING, + wtWebioAn1AlarmDelayTime OCTET STRING + +} + +wtWebioAn1AlarmTrigger OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: Sensor 1 + Bit 1: Timer + Bit 2: ColdStart + Bit 3: WarmStart" + ::= { wtWebioAn1AlarmEntry 1 } + +wtWebioAn1AlarmMin OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum Temperatur in Grad mit maximal 2 Nachkommastellen." + ::= { wtWebioAn1AlarmEntry 2 } + +wtWebioAn1AlarmMax OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum Temperatur in Grad mit maximal 2 Nachkommastellen." + ::= { wtWebioAn1AlarmEntry 3 } + +wtWebioAn1AlarmInterval OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sendeintervall von Alarmmeldungen." + ::= { wtWebioAn1AlarmEntry 4 } + +wtWebioAn1AlarmEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Alarmfreischaltung: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: Mail Enable + Bit 1: SNMP Trap enable + Bit 2: TCP Client enable" + ::= { wtWebioAn1AlarmEntry 5 } + +wtWebioAn1AlarmEMailAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "E-Mail Adresse, an die die Alarmmail gesendet werden soll." + ::= { wtWebioAn1AlarmEntry 6 } + +wtWebioAn1AlarmMailSubject OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Betreffzeile der Alarmmail." + ::= { wtWebioAn1AlarmEntry 7 } + +wtWebioAn1AlarmMailText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Text der Alarmmail: liefert die aktuelle Temperatur. + liefert die aktuelle Zeit." + ::= { wtWebioAn1AlarmEntry 8 } + +wtWebioAn1AlarmManagerIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name oder IP-Adresse des SNMP-Managers, der den Trap entgegen nimmt." + ::= { wtWebioAn1AlarmEntry 9 } + +wtWebioAn1AlarmTrapText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im Trapbody gesendet." + ::= { wtWebioAn1AlarmEntry 10 } + +wtWebioAn1AlarmMailOptions OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Optionen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0 : Attach Thermo.csv Enable + Bit 1-7: ungenutzt" + ::= { wtWebioAn1AlarmEntry 11 } + +wtWebioAn1AlarmTcpIpAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des Gerätes, dass eine TCP-Nachricht empfangen soll." + ::= { wtWebioAn1AlarmEntry 12 } + +wtWebioAn1AlarmTcpPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Portnummer des Gerätes, dass eine TCP-Nachricht empfangen soll." + ::= { wtWebioAn1AlarmEntry 13 } + +wtWebioAn1AlarmTcpText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im TCP Trapbody gesendet." + ::= { wtWebioAn1AlarmEntry 14 } + +wtWebioAn1AlarmHysteresis OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bei Überschreiten der Temperatur Min+Hyst. und Unterschreiten der Temperatur Max-Hyst. + wird der Alarm gelöscht: pos. Temperaturdifferenz in Grad mit maximal 2 Nachkommastellen." + ::= { wtWebioAn1AlarmEntry 15 } + +wtWebioAn1AlarmClearMailSubject OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Betreffzeile der Alarm Clear Mail." + ::= { wtWebioAn1AlarmEntry 16 } + +wtWebioAn1AlarmClearMailText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Text der Alarm Clear Mail: liefert die aktuelle Temperatur; n = 1..8. + liefert die aktuelle Zeit." + ::= { wtWebioAn1AlarmEntry 17 } + +wtWebioAn1AlarmClearTrapText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im Trapbody gesendet." + ::= { wtWebioAn1AlarmEntry 18 } + +wtWebioAn1AlarmClearTcpText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im TCP Trapbody gesendet." + ::= { wtWebioAn1AlarmEntry 19 } + +wtWebioAn1AlarmDeltaTemp OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximale Temperaturänderung in Grad/min mit maximal 2 Nachkommastellen. + Es wird ein Mittelwert einer Periode von 5 Minuten verglichen." + ::= { wtWebioAn1AlarmEntry 20 } + +wtWebioAn1AlarmDelayTime OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Der Alarm wird erst ausgelöst, wenn für die Dauer dieser Zeit + die Alarmbedingungen erfüllt sind (Zeit in Minuten)." + ::= { wtWebioAn1AlarmEntry 21 } + +-- wtWebioAn1Datalogger Group +-------------------------------- + +wtWebioAn1LoggerTimebase OBJECT-TYPE + SYNTAX INTEGER { + wtWebioAn1Datalogger-1Min(1), + wtWebioAn1Datalogger-5Min(2), + wtWebioAn1Datalogger-15Min(3), + wtWebioAn1Datalogger-60Min(4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Zeitbasis des Dataloggers" + ::= { wtWebioAn1Datalogger 1 } + +wtWebioAn1LoggerSensorSel OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: Sensor 1" + ::= { wtWebioAn1Datalogger 2 } + +-- wtWebioAn1Protocol Group +---------------------------- + +wtWebioAn1PrtclUdpPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Udp Port, an den die Udp-Anfragen GET Single gesendet werden können" + ::= { wtWebioAn1PrtclUDP 1 } + +wtWebioAn1PrtclSnmpCommunityStringRead OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Community string read only" + ::= { wtWebioAn1PrtclSNMP 1 } + +wtWebioAn1PrtclSnmpCommunityStringReadWrite OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Community string read / write" + ::= { wtWebioAn1PrtclSNMP 2 } + +wtWebioAn1SystemTrapManagerIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name oder IP-Adresse des SNMP-Managers, der den System Trap entgegen nimmt." + ::= { wtWebioAn1PrtclSNMP 3 } + +wtWebioAn1SystemTrapEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: ColdStart + Bit 1: WarmStart + Bit 2-7: ungenutzt" + ::= { wtWebioAn1PrtclSNMP 4 } + +wtWebioAn1PrtclHttpPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "HTTP Port, an den die HTTP-Anfragen GET Single gesendet werden können" + ::= { wtWebioAn1PrtclHTTP 1 } + + +-- wtWebioAn1Enable Group +---------------------------- + +wtWebioAn1Enables OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: Update enable + Bit 1: Mail enable + Bit 2: Snmp enable + Bit 3: UDP enable + Bit 4: Get Singel Header enable + Bit 5: Apply Timezone + Bit 6: Apply Summertime + Bit 7: Apply TimeServer" + ::= { wtWebioAn1Enable 1 } + +-- wtWebioAn1Startup Group +---------------------------- + +wtWebioAn1StartupSite OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Startseite: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 1: Index.htm + Bit 2: Home.htm + Bit 3: User.htm + Es darf jeweils nur eine Seite ausgewählt sein." + ::= { wtWebioAn1Startup 1 } + +-- wtWebioAn1Ports Group +---------------------------- + +-- Table + +wtWebioAn1PortTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebioAn1PortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Einstellungen abhängig von der Sensornummer." + ::= { wtWebioAn1Ports 1 } + +wtWebioAn1PortEntry OBJECT-TYPE + SYNTAX WtWebioAn1PortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Sensor-Parameter der einzelnen Sensoren." + INDEX { wtWebioAn1SensorNo } + ::= { wtWebioAn1PortTable 1 } + +WtWebioAn1PortEntry ::= SEQUENCE { + wtWebioAn1PortName OCTET STRING, + wtWebioAn1PortText OCTET STRING, + wtWebioAn1PortOffset1 OCTET STRING, + wtWebioAn1PortTemperature1 OCTET STRING, + wtWebioAn1PortOffset2 OCTET STRING, + wtWebioAn1PortTemperature2 OCTET STRING, + wtWebioAn1PortComment OCTET STRING +} + +wtWebioAn1PortName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name des Sensors." + ::= { wtWebioAn1PortEntry 1 } + +wtWebioAn1PortText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Beschreibung des Sensors." + ::= { wtWebioAn1PortEntry 2 } + +wtWebioAn1PortOffset1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 1." + ::= { wtWebioAn1PortEntry 3 } + +wtWebioAn1PortTemperature1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Referenztemperatur 1 in Grad mit max. 2 Nachkommastellen." + ::= { wtWebioAn1PortEntry 4 } + +wtWebioAn1PortOffset2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 2." + ::= { wtWebioAn1PortEntry 5 } + +wtWebioAn1PortTemperature2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Referenztemperatur 2 in Grad mit max. 2 Nachkommastellen." + ::= { wtWebioAn1PortEntry 6 } + +wtWebioAn1PortComment OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Angaben zu Datum, Referenzgerät, Operator." + ::= { wtWebioAn1PortEntry 7 } + +-- wtWebioAn1Manufact Group +---------------------------- + +wtWebioAn1MfName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Hersteller Firmenname" + ::= { wtWebioAn1Manufact 1 } + +wtWebioAn1MfAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Adresse des Herstellers." + ::= { wtWebioAn1Manufact 2 } + +wtWebioAn1MfHotline OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Hotline des Herstellers." + ::= { wtWebioAn1Manufact 3 } + +wtWebioAn1MfInternet OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Internet-Adresse des Herstellers." + ::= { wtWebioAn1Manufact 4 } + +wtWebioAn1MfDeviceTyp OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Gerätebezeichnung (Typ) des Herstellers." + ::= { wtWebioAn1Manufact 5 } + +wtWebioAn1MfOrderNo OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bestellnummer des Gerätes des Herstellers." + ::= { wtWebioAn1Manufact 6 } + + + +-- TRAP DEFINITIONS + +-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen + +wtWebioAn1Alert1 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 1" + --#SUMMARY "Alarm 1: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 31 + +wtWebioAn1Alert2 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 2" + --#SUMMARY "Alarm 2: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 32 + +wtWebioAn1Alert3 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 3" + --#SUMMARY "Alarm 3: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 33 + +wtWebioAn1Alert4 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 4" + --#SUMMARY "Alarm 4: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 34 + +wtWebioAn1Alert5 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 5" + --#SUMMARY "Alarm 5: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 35 + +wtWebioAn1Alert6 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 6" + --#SUMMARY "Alarm 6: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 36 + +wtWebioAn1Alert7 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 7" + --#SUMMARY "Alarm 7: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 37 + +wtWebioAn1Alert8 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Alarm 8" + --#SUMMARY "Alarm 8: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 38 + +wtWebioAn1Alert9 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 1" + --#SUMMARY "Alarm 1: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 91 + +wtWebioAn1Alert10 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 2" + --#SUMMARY "Alarm 2: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 92 + +wtWebioAn1Alert11 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 3" + --#SUMMARY "Alarm 3: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 93 + +wtWebioAn1Alert12 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 4" + --#SUMMARY "Alarm 4: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 94 + +wtWebioAn1Alert13 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 5" + --#SUMMARY "Alarm 5: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 95 + +wtWebioAn1Alert14 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 6" + --#SUMMARY "Alarm 6: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 96 + +wtWebioAn1Alert15 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 7" + --#SUMMARY "Alarm 7: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 97 + +wtWebioAn1Alert16 TRAP-TYPE + ENTERPRISE wtWebioAn1 + VARIABLES { wtWebioAn1AlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "WebThermometer Release Alarm 8" + --#SUMMARY "Alarm 8: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 98 + + +END diff --git a/MIBs/aruba-wlan.my b/MIBs/aruba-wlan.my new file mode 100644 index 0000000..7efff06 --- /dev/null +++ b/MIBs/aruba-wlan.my @@ -0,0 +1,5938 @@ +-- ArubaOS 6.4.2.3-4.1.1.2_48114 +-- vim:set ts=4 sw=4: +WLSX-WLAN-MIB DEFINITIONS ::= BEGIN + + IMPORTS + TEXTUAL-CONVENTION FROM SNMPv2-TC + + MODULE-IDENTITY, + OBJECT-TYPE, + snmpModules, + Integer32, + Unsigned32, + Counter32, + IpAddress, + NOTIFICATION-TYPE + FROM SNMPv2-SMI + + TDomain, + DisplayString, + PhysAddress, + TAddress, + TimeInterval, + RowStatus, + StorageType, + TestAndIncr, + MacAddress, + TruthValue + FROM SNMPv2-TC + + ifIndex + FROM RFC1213-MIB + + ArubaEnableValue, + ArubaFrameType, + ArubaActiveState, + ArubaRogueApType, + ArubaAuthenticationMethods, + ArubaEncryptionMethods, + ArubaPhyType, + ArubaVoipProtocolType, + ArubaVlanValidRange, + ArubaAccessPointMode, + ArubaAPStatus, + ArubaEnet1Mode, + ArubaUnprovisionedStatus, + ArubaMonitorMode, + ArubaAntennaSetting, + ArubaMeshRole, + ArubaHTMode, + ArubaHTExtChannel + FROM ARUBA-TC + + OBJECT-GROUP + FROM SNMPv2-CONF + wlsxEnterpriseMibModules + FROM ARUBA-MIB; + + wlsxWlanMIB MODULE-IDENTITY + LAST-UPDATED "1001261806Z" + ORGANIZATION "Aruba Wireless Networks" + CONTACT-INFO + "Postal: 1322 Crossman Avenue + Sunnyvale, CA 94089 + E-mail: dl-support@arubanetworks.com + Phone: +1 408 227 4500" + DESCRIPTION + "This MIB module defines MIB objects which provide + information about the Wireless Management System (WMS) in the + Aruba Controller." + REVISION "1001261806Z" + DESCRIPTION + "The initial revision." + ::= { wlsxEnterpriseMibModules 5 } + + wlsxWlanConfigGroup OBJECT IDENTIFIER ::= { wlsxWlanMIB 1 } + wlsxWlanStateGroup OBJECT IDENTIFIER ::= { wlsxWlanMIB 2 } + wlsxWlanStatsGroup OBJECT IDENTIFIER ::= { wlsxWlanMIB 3 } + wlsxRAPTraps OBJECT IDENTIFIER ::= { wlsxWlanMIB 100 } + +-- wlsxWlanAccessPointInfoGroup contains a Local Access Point Information Table. +-- which lists all the APs connected to the controller, a Global AP Info Table +-- which lists all the APs in the Aruba Domain. The Global table is valid only +-- on the Master controller. The Group also contains two scalar objects which +-- indicate the total number of APs and the total number of Clients connected. + + wlsxWlanAccessPointInfoGroup OBJECT IDENTIFIER ::= { wlsxWlanStateGroup 1 } + wlsxWlanStationInfoGroup OBJECT IDENTIFIER ::= { wlsxWlanStateGroup 2 } + wlsxWlanAssociationInfoGroup OBJECT IDENTIFIER ::= { wlsxWlanStateGroup 3 } + wlsxWlanAccessPointStatsGroup OBJECT IDENTIFIER ::= { wlsxWlanStatsGroup 1 } + wlsxWlanStationStatsGroup OBJECT IDENTIFIER ::= { wlsxWlanStatsGroup 2 } + wlsxWlanSwitchStatsGroup OBJECT IDENTIFIER ::= { wlsxWlanStatsGroup 3 } + wlsxSSIDConfigGroup OBJECT IDENTIFIER ::= { wlsxWlanConfigGroup 1 } + wlsxAPConfigGroup OBJECT IDENTIFIER ::= { wlsxWlanConfigGroup 2 } + + wlsxWlanTotalNumAccessPoints OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Total Number of Access Points connected to the controller. + " + ::= { wlsxWlanAccessPointInfoGroup 1 } + + wlsxWlanTotalNumStationsAssociated OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Total Number of Stations Associated to the controller. + " + ::= { wlsxWlanAccessPointInfoGroup 2 } + +-- AP Group Table + wlsxWlanAPGroupTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanAPGroupEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This Table lists all the Access Points Groups configured in the + Aruba controller. + " + ::= { wlsxWlanAccessPointInfoGroup 3 } + + wlsxWlanAPGroupEntry OBJECT-TYPE + SYNTAX WlanAPGroupEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "AP Group Entry" + INDEX {wlanAPGroup} + ::= { wlsxWlanAPGroupTable 1 } + + WlanAPGroupEntry ::= + SEQUENCE { + wlanAPGroup DisplayString, + wlanAPNumAps Integer32 + } + + wlanAPGroup OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + The name of an AP group + " + ::= { wlsxWlanAPGroupEntry 1 } + + wlanAPNumAps OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of APs in the AP Group + " + ::= { wlsxWlanAPGroupEntry 2 } + + + -- AP Table + + wlsxWlanAPTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanAPEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This table lists all the Access Points connected to the + controller. + " + ::= { wlsxWlanAccessPointInfoGroup 4 } + + wlsxWlanAPEntry OBJECT-TYPE + SYNTAX WlanAPEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Access Point Entry" + INDEX {wlanAPMacAddress} + ::= { wlsxWlanAPTable 1 } + + WlanAPEntry ::= + SEQUENCE { + wlanAPMacAddress MacAddress, + wlanAPIpAddress IpAddress, + wlanAPName DisplayString, + wlanAPGroupName DisplayString, + wlanAPModel OBJECT IDENTIFIER, + wlanAPSerialNumber DisplayString, + wlanAPdot11aAntennaGain Integer32, + wlanAPdot11gAntennaGain Integer32, + wlanAPNumRadios Integer32, + wlanAPEnet1Mode ArubaEnet1Mode, + wlanAPIpsecMode ArubaEnableValue, + wlanAPUpTime TimeTicks, + wlanAPModelName DisplayString, + wlanAPLocation DisplayString, + wlanAPBuilding Integer32, + wlanAPFloor Integer32, + wlanAPLoc Integer32, + wlanAPExternalAntenna ArubaAntennaSetting, + wlanAPStatus ArubaAPStatus, + wlanAPNumBootstraps Integer32, + wlanAPNumReboots Integer32, + wlanAPUnprovisioned ArubaUnprovisionedStatus, + wlanAPMonitorMode ArubaMonitorMode, + wlanAPFQLNBuilding DisplayString, + wlanAPFQLNFloor DisplayString, + wlanAPFQLN DisplayString, + wlanAPFQLNCampus DisplayString, + wlanAPLongitude DisplayString, + wlanAPLatitude DisplayString, + wlanAPAltitude DisplayString, + wlanAPMeshRole ArubaMeshRole, + wlanAPSysLocation DisplayString, + wlanAPHwVersion DisplayString, + wlanAPSwVersion DisplayString, + wlanAPNumWarmReboots Integer32, + wlanAPOuterIpAddress IpAddress, + wlanAPRemoteLanIpAddress IpAddress, + wlanAPActiveUplink INTEGER, + wlanAPSwitchIpAddress IpAddress, + wlanAPStandbyIpAddress IpAddress, + wlanAPConnectedAsStandby INTEGER + } + + wlanAPMacAddress OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + Ethernet MAC Address of the Access Point + " + ::= { wlsxWlanAPEntry 1 } + + wlanAPIpAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + IP Address of the Access Point + " + ::= { wlsxWlanAPEntry 2 } + + wlanAPName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + Host name of the Access Point. + " + ::= { wlsxWlanAPEntry 3 } + + wlanAPGroupName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + Group Name of the Access Point. + " + ::= { wlsxWlanAPEntry 4 } + + wlanAPModel OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Sys OID of the Access Point. + " + ::= { wlsxWlanAPEntry 5 } + + wlanAPSerialNumber OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Serial Number of the Access Point. + " + ::= { wlsxWlanAPEntry 6 } + + wlanAPdot11aAntennaGain OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Configured antenna gain for 'A' Radio. + " + ::= { wlsxWlanAPEntry 7 } + + wlanAPdot11gAntennaGain OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Configured antenna gain for 'G' Radio. + " + ::= { wlsxWlanAPEntry 8 } + + wlanAPNumRadios OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Number of Radios in the Access Point. + " + ::= { wlsxWlanAPEntry 9 } + + wlanAPEnet1Mode OBJECT-TYPE + SYNTAX ArubaEnet1Mode + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Enet1 Mode of the Access Point. + " + ::= { wlsxWlanAPEntry 10 } + + wlanAPIpsecMode OBJECT-TYPE + SYNTAX ArubaEnableValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + IPSEC Mode of the Access Point. + " + ::= { wlsxWlanAPEntry 11 } + + wlanAPUpTime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Time (in hundredths of seconds) since the last time the Access + Point bootstrapped with the controller. + " + ::= { wlsxWlanAPEntry 12 } + + wlanAPModelName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Model name of the Access Point. + " + ::= { wlsxWlanAPEntry 13 } + + wlanAPLocation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Location of the Access Point. + " + ::= { wlsxWlanAPEntry 14 } + + wlanAPBuilding OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + AP Building Number. + " + ::= { wlsxWlanAPEntry 15 } + + wlanAPFloor OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + AP Floor Number. + " + ::= { wlsxWlanAPEntry 16 } + + wlanAPLoc OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + AP Location. + " + ::= { wlsxWlanAPEntry 17 } + + wlanAPExternalAntenna OBJECT-TYPE + SYNTAX ArubaAntennaSetting + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + AP Antenna Status. + " + ::= { wlsxWlanAPEntry 18 } + + wlanAPStatus OBJECT-TYPE + SYNTAX ArubaAPStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + AP Status. + " + ::= { wlsxWlanAPEntry 19 } + + wlanAPNumBootstraps OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Number of times the AP has bootstrapped with the controller. + " + ::= { wlsxWlanAPEntry 20 } + + wlanAPNumReboots OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Number of times the AP has rebooted. + " + ::= { wlsxWlanAPEntry 21 } + + wlanAPUnprovisioned OBJECT-TYPE + SYNTAX ArubaUnprovisionedStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Indicates whether the AP is unprovisioned due to lack of + antenna gain or location code settings. + " + ::= { wlsxWlanAPEntry 22 } + + wlanAPMonitorMode OBJECT-TYPE + SYNTAX ArubaMonitorMode + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Indicates whether any radio on this AP is acting as an + air monitor. + " + ::= { wlsxWlanAPEntry 23 } + + wlanAPFQLNBuilding OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The building component of the AP's FQLN. + " + ::= { wlsxWlanAPEntry 24 } + + wlanAPFQLNFloor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The floor component of the AP's FQLN. + " + ::= { wlsxWlanAPEntry 25 } + + wlanAPFQLN OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + The AP's Fully Qualified Location Name (FQLN). + " + ::= { wlsxWlanAPEntry 26 } + + wlanAPFQLNCampus OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The campus component of the AP's FQLN. + " + ::= { wlsxWlanAPEntry 27 } + + wlanAPLongitude OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + Longitude of the AP. Signed floating-point value. + " + ::= { wlsxWlanAPEntry 28 } + + wlanAPLatitude OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + Latitude of the AP. Signed floating-point value. + " + ::= { wlsxWlanAPEntry 29 } + + wlanAPAltitude OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + Altitude of the AP. Signed floating-point value. + " + ::= { wlsxWlanAPEntry 30 } + + wlanAPMeshRole OBJECT-TYPE + SYNTAX ArubaMeshRole + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + AP Mesh role + " + ::= { wlsxWlanAPEntry 31 } + + wlanAPSysLocation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + AP sysLocation + " + ::= { wlsxWlanAPEntry 32 } + + wlanAPHwVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Hardware version of the AP. + " + ::= { wlsxWlanAPEntry 33 } + + wlanAPSwVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Software version of the AP. + " + ::= { wlsxWlanAPEntry 34 } + + wlanAPNumWarmReboots OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Number of times the AP has warm-rebooted. + " + ::= { wlsxWlanAPEntry 35 } + + wlanAPOuterIpAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Outer IP Address of the Access Point. + " + ::= { wlsxWlanAPEntry 36 } + + wlanAPRemoteLanIpAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + LAN IP Address of the Remote Access Point. + " + ::= { wlsxWlanAPEntry 37 } + + wlanAPActiveUplink OBJECT-TYPE + SYNTAX INTEGER { + ethernet(1), + usb(2), + pppoe(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Uplink of the RAP(Ethernet or USB). + " + ::= { wlsxWlanAPEntry 38 } + + wlanAPSwitchIpAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Access points' Serving Controller's IP Address. + " + ::= { wlsxWlanAPEntry 39 } + + wlanAPStandbyIpAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Access points' Standby Controller's IP Address. + " + ::= { wlsxWlanAPEntry 40 } + + wlanAPConnectedAsStandby OBJECT-TYPE + SYNTAX INTEGER { + active(0), + standby(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Access point connected as active/standby. + " + ::= { wlsxWlanAPEntry 41 } + + +-- Radio table is indexed by the Mac Address of the AP and the type of the +-- radio. + + wlsxWlanRadioTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanRadioEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This table lists all the radios known to the + controller. + " + ::= { wlsxWlanAccessPointInfoGroup 5 } + + wlsxWlanRadioEntry OBJECT-TYPE + SYNTAX WlanRadioEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "AP Radio Entry" + INDEX {wlanAPMacAddress, wlanAPRadioNumber} + ::= { wlsxWlanRadioTable 1 } + + WlanRadioEntry ::= + SEQUENCE { + wlanAPRadioNumber Integer32, + wlanAPRadioType ArubaPhyType, + wlanAPRadioChannel Integer32, + wlanAPRadioTransmitPower Integer32, + wlanAPRadioMode ArubaAccessPointMode, + wlanAPRadioUtilization Integer32, + wlanAPRadioNumAssociatedClients Integer32, + wlanAPRadioNumMonitoredClients Integer32, + wlanAPRadioNumActiveBSSIDs Integer32, + wlanAPRadioNumMonitoredBSSIDs Integer32, + wlanAPRadioBearing DisplayString, + wlanAPRadioTiltAngle DisplayString, + wlanAPRadioHTMode ArubaHTMode, + wlanAPRadioHTExtChannel ArubaHTExtChannel, + wlanAPRadioHTChannel DisplayString, + wlanAPRadioAPName DisplayString + } + + wlanAPRadioNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + The radio number + " + ::= { wlsxWlanRadioEntry 1 } + + wlanAPRadioType OBJECT-TYPE + SYNTAX ArubaPhyType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + Type of the Radio + " + ::= { wlsxWlanRadioEntry 2 } + + wlanAPRadioChannel OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The channel the radio is currently operating on. + " + ::= { wlsxWlanRadioEntry 3 } + + wlanAPRadioTransmitPower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The current power level of the radio. + " + ::= { wlsxWlanRadioEntry 4 } + + wlanAPRadioMode OBJECT-TYPE + SYNTAX ArubaAccessPointMode + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The Mode in which the radio is operating. + " + ::= { wlsxWlanRadioEntry 5 } + + wlanAPRadioUtilization OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The Utilization of the radio as a percentage of the total capacity. + " + ::= { wlsxWlanRadioEntry 6 } + + + wlanAPRadioNumAssociatedClients OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of Clients associated to this radio. + " + ::= { wlsxWlanRadioEntry 7 } + + + wlanAPRadioNumMonitoredClients OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of Clients this Radio is monitoring. + " + ::= { wlsxWlanRadioEntry 8 } + + + wlanAPRadioNumActiveBSSIDs OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of active BSSIDs on this Radio. + " + ::= { wlsxWlanRadioEntry 9 } + + + wlanAPRadioNumMonitoredBSSIDs OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of AP BSSIDs this radio is monitoring. + " + ::= { wlsxWlanRadioEntry 10 } + + wlanAPRadioBearing OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + Antenna Bearing in degrees from True North. + Unsigned floating-point value. Range: 0-360. + " + ::= { wlsxWlanRadioEntry 11 } + + wlanAPRadioTiltAngle OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + Tilt angle of antenna in degrees. -ve for downtilt, + +ve for uptilt. Signed floating-point value. Range: -90 to +90. + " + ::= { wlsxWlanRadioEntry 12 } + + wlanAPRadioHTMode OBJECT-TYPE + SYNTAX ArubaHTMode + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The HT mode of the radio, if any. + " + ::= { wlsxWlanRadioEntry 13 } + + wlanAPRadioHTExtChannel OBJECT-TYPE + SYNTAX ArubaHTExtChannel + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Indicates the offset of the 40MHz extension channel, if any. + " + ::= { wlsxWlanRadioEntry 14 } + + wlanAPRadioHTChannel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + A display string indicating the current channel. If wlanAPRadioHTExtChannel + is set to 'above' or 'below', then the channel number will be appended + with '+' or '-' respectively. + " + ::= { wlsxWlanRadioEntry 15 } + + wlanAPRadioAPName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name of the AP the radio belongs to" + ::= { wlsxWlanRadioEntry 16 } + +-- Local Access Point Table. + + wlsxWlanAPBssidTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanAPBssidEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This table lists all the BSSIDs active on this controller. + " + ::= { wlsxWlanAccessPointInfoGroup 7 } + + wlsxWlanAPBssidEntry OBJECT-TYPE + SYNTAX WlanAPBssidEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "BSSID Entry" + INDEX {wlanAPMacAddress, wlanAPRadioNumber, wlanAPBSSID} + ::= { wlsxWlanAPBssidTable 1 } + + WlanAPBssidEntry ::= + SEQUENCE { + wlanAPBSSID MacAddress, + wlanAPESSID DisplayString, + wlanAPBssidSlot Unsigned32, + wlanAPBssidPort Unsigned32, + wlanAPBssidPhyType ArubaPhyType, + wlanAPBssidRogueType ArubaRogueApType, + wlanAPBssidMode INTEGER, + wlanAPBssidChannel INTEGER, + wlanAPBssidUpTime TimeTicks, + wlanAPBssidInactiveTime TimeTicks, + wlanAPBssidLoadBalancing TruthValue, + wlanAPBssidNumAssociatedStations Unsigned32, + wlanAPBssidAPMacAddress MacAddress, + wlanAPBssidPhyNumber Integer32, + wlanAPBssidHTMode ArubaHTMode, + wlanAPBssidHTExtChannel ArubaHTExtChannel, + wlanAPBssidHTChannel DisplayString, + wlanAPBssidSnr Integer32 + } + + wlanAPBSSID OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + The MAC address of the Access Point. + " + ::= { wlsxWlanAPBssidEntry 1 } + + wlanAPESSID OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + ESSID this BSSID is advertising. + " + ::= { wlsxWlanAPBssidEntry 2 } + + wlanAPBssidSlot OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Slot to which the Access Point is connected. + " + ::= { wlsxWlanAPBssidEntry 3 } + + wlanAPBssidPort OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Port to which the Access Point is connected. + " + ::= { wlsxWlanAPBssidEntry 4 } + + wlanAPBssidPhyType OBJECT-TYPE + SYNTAX ArubaPhyType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Physical Layer Protocol support of the AP. + " + ::= { wlsxWlanAPBssidEntry 5 } + + wlanAPBssidRogueType OBJECT-TYPE + SYNTAX ArubaRogueApType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The type of the Rogue. + " + ::= { wlsxWlanAPBssidEntry 6 } + + wlanAPBssidMode OBJECT-TYPE + SYNTAX INTEGER{ + ap(1), + am(2), + mpp(3), + mp(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Indicates whether the Access point is an Air Monitor or regular AP + or Mesh Portal or Mesh Point. + " + ::= { wlsxWlanAPBssidEntry 7 } + + wlanAPBssidChannel OBJECT-TYPE + SYNTAX INTEGER(1..165) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The current operating channel. + " + ::= { wlsxWlanAPBssidEntry 8 } + + wlanAPBssidUpTime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Time (in hundredths of seconds) since the tunnel was created + between the access point and controller + " + ::= { wlsxWlanAPBssidEntry 9 } + + wlanAPBssidInactiveTime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Time (in hundredths of seconds) since any activity took place on + the BSSID. + " + ::= { wlsxWlanAPBssidEntry 10 } + + wlanAPBssidLoadBalancing OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Indicates whether load balancing is enabled or not. + " + ::= { wlsxWlanAPBssidEntry 11 } + + wlanAPBssidNumAssociatedStations OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Indicates the number of stations associated to this BSSID. + " + ::= { wlsxWlanAPBssidEntry 12 } + + + wlanAPBssidAPMacAddress OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Indicates the Access Point to which this BSSID belongs. + " + ::= { wlsxWlanAPBssidEntry 13 } + + wlanAPBssidPhyNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Indicates the radio number to which this BSSID belongs. + " + ::= { wlsxWlanAPBssidEntry 14 } + + wlanAPBssidHTMode OBJECT-TYPE + SYNTAX ArubaHTMode + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Indicates the HT mode of this BSSID, if any. + " + ::= { wlsxWlanAPBssidEntry 15 } + + wlanAPBssidHTExtChannel OBJECT-TYPE + SYNTAX ArubaHTExtChannel + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Indicates the offset of the 40MHz extension channel, if any. + " + ::= { wlsxWlanAPBssidEntry 16 } + + wlanAPBssidHTChannel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + A display string indicating the current channel. If wlanAPBssidHTExtChannel + is set to 'above' or 'below', then the channel number will be appended + with '+' or '-' respectively. + " + ::= { wlsxWlanAPBssidEntry 17 } + + wlanAPBssidSnr OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Indicates the Signal Noise Ratio of this BSSID. + " + ::= { wlsxWlanAPBssidEntry 18 } + +-- ESSID Table + + wlsxWlanESSIDTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanESSIDEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This Table lists all the ESSIDs advertised by this controller. + " + ::= { wlsxWlanAccessPointInfoGroup 8 } + + wlsxWlanESSIDEntry OBJECT-TYPE + SYNTAX WlanESSIDEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "ESSID Entry" + INDEX {wlanESSID} + ::= { wlsxWlanESSIDTable 1 } + + WlanESSIDEntry ::= + SEQUENCE { + wlanESSID DisplayString, + wlanESSIDNumStations Unsigned32, + wlanESSIDNumAccessPointsUp Unsigned32, + wlanESSIDNumAccessPointsDown Unsigned32, + wlanESSIDEncryptionType ArubaEncryptionMethods + } + + wlanESSID OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..64)) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + The ESSID being advertised. + " + ::= { wlsxWlanESSIDEntry 1 } + + wlanESSIDNumStations OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of stations connected to this ESSID. + " + ::= { wlsxWlanESSIDEntry 2 } + + wlanESSIDNumAccessPointsUp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of APs currently advertising this ESSID. + " + ::= { wlsxWlanESSIDEntry 3 } + + wlanESSIDNumAccessPointsDown OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of APs configured to advertise this ESSID that + are not currently operational. + " + ::= { wlsxWlanESSIDEntry 4 } + + wlanESSIDEncryptionType OBJECT-TYPE + SYNTAX ArubaEncryptionMethods + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The encryption methods supported on this ESSID. + " + ::= { wlsxWlanESSIDEntry 5 } + +-- ESSID Vlan Pool Table + + wlsxWlanESSIDVlanPoolTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanESSIDVlanPoolEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This Table lists all the VLANs associated with this ESSID. + " + ::= { wlsxWlanAccessPointInfoGroup 9 } + + wlsxWlanESSIDVlanPoolEntry OBJECT-TYPE + SYNTAX WlanESSIDVlanPoolEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "ESSID Vlan Pool Entry" + INDEX {wlanESSID, wlanESSIDVlanId} + ::= { wlsxWlanESSIDVlanPoolTable 1 } + + WlanESSIDVlanPoolEntry ::= + SEQUENCE { + wlanESSIDVlanId Unsigned32, + wlanESSIDVlanPoolStatus RowStatus + } + + wlanESSIDVlanId OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + VLAN which is part of the VLAN pool for this ESSID. + " + ::= { wlsxWlanESSIDVlanPoolEntry 1 } + + wlanESSIDVlanPoolStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + " + Row status object used to indicate the status of the row. + " + ::= { wlsxWlanESSIDVlanPoolEntry 2 } + +--Station Info Group contains the State information for the stations. + +--Station Table contains all the station associated with an AP. + + wlsxWlanStationTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanStationEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This Table lists all the wireless stations associated with the + Access points connected to this controller. + " + + ::= { wlsxWlanStationInfoGroup 1} + + wlsxWlanStationEntry OBJECT-TYPE + SYNTAX WlanStationEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Station Entry" + INDEX {wlanStaPhyAddress} + ::= { wlsxWlanStationTable 1 } + + WlanStationEntry ::= + SEQUENCE { + wlanStaPhyAddress MacAddress, + wlanStaApBssid MacAddress, + wlanStaPhyType ArubaPhyType, + wlanStaIsAuthenticated TruthValue, + wlanStaIsAssociated TruthValue, + wlanStaChannel INTEGER, + wlanStaVlanId ArubaVlanValidRange, + wlanStaVOIPState TruthValue, + wlanStaVOIPProtocol ArubaVoipProtocolType, + wlanStaTransmitRate Unsigned32, + wlanStaAssociationID Unsigned32, + wlanStaAccessPointESSID DisplayString, + wlanStaPhyNumber Integer32, + wlanStaRSSI Integer32, + wlanStaUpTime TimeTicks, + wlanStaHTMode ArubaHTMode, + wlanStaTransmitRateCode Unsigned32 + } + + wlanStaPhyAddress OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + The Physical Address of the Station. + " + ::= { wlsxWlanStationEntry 1 } + + wlanStaApBssid OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + The Access point to which this station last associated to. + " + ::= { wlsxWlanStationEntry 2 } + + wlanStaPhyType OBJECT-TYPE + SYNTAX ArubaPhyType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Type of the Station. + " + ::= { wlsxWlanStationEntry 3 } + + wlanStaIsAuthenticated OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Indicates whether the station is authenticated. + " + ::= { wlsxWlanStationEntry 4 } + + wlanStaIsAssociated OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Indicates whether the station is associated. + " + ::= { wlsxWlanStationEntry 5 } + + wlanStaChannel OBJECT-TYPE + SYNTAX INTEGER(1..165) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Channel on which the station is associated. + " + ::= { wlsxWlanStationEntry 6 } + + wlanStaVlanId OBJECT-TYPE + SYNTAX ArubaVlanValidRange + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + VLAN in which the station is present. + " + ::= { wlsxWlanStationEntry 7 } + + wlanStaVOIPState OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The State of VoIP for this station. + " + ::= { wlsxWlanStationEntry 8 } + + wlanStaVOIPProtocol OBJECT-TYPE + SYNTAX ArubaVoipProtocolType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + If VoIP is enabled, the type of the protocol supported. + " + ::= { wlsxWlanStationEntry 9 } + + wlanStaTransmitRate OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Transmit rate with which the Station is associated with this system. + " + ::= { wlsxWlanStationEntry 10 } + + wlanStaAssociationID OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + AID with which the Station is associated with this system. + " + ::= { wlsxWlanStationEntry 11 } + + wlanStaAccessPointESSID OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + ESSID of the Access point + " + ::= { wlsxWlanStationEntry 12 } + + wlanStaPhyNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Radio PHY number to which the station is associated + " + ::= { wlsxWlanStationEntry 13 } + + wlanStaRSSI OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Signal to Noise ratio for the station. + " + ::= { wlsxWlanStationEntry 14 } + + + wlanStaUpTime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Time since the station associated to the current BSSID. + " + ::= { wlsxWlanStationEntry 15 } + + wlanStaHTMode OBJECT-TYPE + SYNTAX ArubaHTMode + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The HT status of the station. + " + ::= { wlsxWlanStationEntry 16 } + + wlanStaTransmitRateCode OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Transmit rate code with which the Station is associated with this system, unit is mbps. + " + ::= { wlsxWlanStationEntry 17 } + +--Station Association Failure Table contains all the Stations that failed to +--associate an ap. + + wlsxWlanStaAssociationFailureTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanStaAssociationFailureEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This Table lists all the stations and the BSSID's to which they + failed to associate. Once a station successfully associates, + association failure entries are not reported for that station. + " + + ::= { wlsxWlanStationInfoGroup 2} + + wlsxWlanStaAssociationFailureEntry OBJECT-TYPE + SYNTAX WlanStaAssociationFailureEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Station Association Failure Entry" + INDEX {wlanStaPhyAddress, wlanAPBSSID} + ::= { wlsxWlanStaAssociationFailureTable 1 } + + WlanStaAssociationFailureEntry ::= + SEQUENCE { + wlanStaAssocFailureApName DisplayString, + wlanStaAssocFailureApEssid DisplayString, + wlanStaAssocFailurePhyNum Integer32, + wlanStaAssocFailurePhyType ArubaPhyType, + wlanStaAssocFailureElapsedTime TimeTicks, + wlanStaAssocFailureReason DisplayString + } + + wlanStaAssocFailureApName OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Name of the Access Point to which this station tried to associate. + " + ::= { wlsxWlanStaAssociationFailureEntry 1 } + + wlanStaAssocFailureApEssid OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + ESSID to which the station association failed. + " + ::= { wlsxWlanStaAssociationFailureEntry 2 } + + wlanStaAssocFailurePhyNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Radio PHY number to which the station tried to associate. + " + ::= { wlsxWlanStaAssociationFailureEntry 3 } + + wlanStaAssocFailurePhyType OBJECT-TYPE + SYNTAX ArubaPhyType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Radio PHY Type of the Station. + " + ::= { wlsxWlanStaAssociationFailureEntry 4 } + + wlanStaAssocFailureElapsedTime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Elapsed time in timeticks after the station's failure to associate. + " + ::= { wlsxWlanStaAssociationFailureEntry 5 } + + wlanStaAssocFailureReason OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..80)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + Reason for the Station association failure + " + ::= { wlsxWlanStaAssociationFailureEntry 6 } + +-- Stats group contains tables for station statistics, BSSID statistics and +-- AP statistics. + + wlsxWlanAPStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanAPStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This Table lists the statistics of all the Access Points connected + to the controller. + " + ::= { wlsxWlanAccessPointStatsGroup 1 } + + wlsxWlanAPStatsEntry OBJECT-TYPE + SYNTAX WlanAPStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Access Point Stats entry" + INDEX {wlanAPMacAddress, wlanAPRadioNumber, wlanAPBSSID} + ::= { wlsxWlanAPStatsTable 1 } + + WlanAPStatsEntry ::= + SEQUENCE { + wlanAPCurrentChannel Unsigned32, + wlanAPNumClients Integer32, + wlanAPTxPkts Counter32, + wlanAPTxBytes Counter32, + wlanAPRxPkts Counter32, + wlanAPRxBytes Counter32, + wlanAPTxDeauthentications Counter32, + wlanAPRxDeauthentications Counter32, + wlanAPChannelThroughput Integer32, + wlanAPFrameRetryRate Integer32, + wlanAPFrameLowSpeedRate Integer32, + wlanAPFrameNonUnicastRate Integer32, + wlanAPFrameFragmentationRate Integer32, + wlanAPFrameBandwidthRate Integer32, + wlanAPFrameRetryErrorRate Integer32, + wlanAPChannelErrorRate Integer32, + wlanAPFrameReceiveErrorRate Integer32, + wlanAPRxDataPkts Counter32, + wlanAPRxDataBytes Counter32, + wlanAPTxDataPkts Counter32, + wlanAPTxDataBytes Counter32, + wlanAPRxDataPkts64 Counter64, + wlanAPRxDataBytes64 Counter64, + wlanAPTxDataPkts64 Counter64, + wlanAPTxDataBytes64 Counter64, + wlanAPWiredRxErrorPkts Counter32, + wlanAPRxErrorPkts Counter32 + } + + wlanAPCurrentChannel OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The channel the AP is currently using. + " + ::= { wlsxWlanAPStatsEntry 1 } + + wlanAPNumClients OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of clients associated to this BSSID. + " + ::= { wlsxWlanAPStatsEntry 2 } + + wlanAPTxPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of packets transmitted on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 3 } + + wlanAPTxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of bytes transmitted on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 4 } + + wlanAPRxPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of packets received on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 5 } + + wlanAPRxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of bytes received on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 6 } + + wlanAPTxDeauthentications OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of deauthentications transmitted on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 7 } + + wlanAPRxDeauthentications OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of deauthentications received on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 8 } + + wlanAPChannelThroughput OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The throughput achieved on this channel. + " + ::= { wlsxWlanAPStatsEntry 9 } + + wlanAPFrameRetryRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of retry + packets as a percentage of the total packets + transmitted and received by this BSSID. + " + ::= { wlsxWlanAPStatsEntry 10 } + + wlanAPFrameLowSpeedRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of low data rate (<= 18Mbps for A/G bands and <=2Mbps + for B band) packets as a percentage of the total packets + transmitted and received by this BSSID + " + ::= { wlsxWlanAPStatsEntry 11 } + + wlanAPFrameNonUnicastRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of broadcast and multicast + packets as a percentage of the total packets + transmitted on this BSSIDchannel. + " + ::= { wlsxWlanAPStatsEntry 12 } + + wlanAPFrameFragmentationRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of fragments + as a percentage of the total packets + transmitted by this BSSID. + " + ::= { wlsxWlanAPStatsEntry 13 } + + wlanAPFrameBandwidthRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The bandwidth of this BSSID in Kbps. + " + ::= { wlsxWlanAPStatsEntry 14 } + + wlanAPFrameRetryErrorRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of error packets + as a percentage of the total packets + received on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 15 } + + wlanAPChannelErrorRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of error packets + as a percentage of the total packets received + on the current channel. + " + ::= { wlsxWlanAPStatsEntry 16 } + + wlanAPFrameReceiveErrorRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of error packets + as a percentage of the total packets + received on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 17 } + + wlanAPRxDataPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + " + The number of packets received on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 18 } + + wlanAPRxDataBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + " + The number of bytes received on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 19 } + + wlanAPTxDataPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + " + The number of packets transmitted on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 20 } + + wlanAPTxDataBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + " + The number of bytes transmitted on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 21 } + + wlanAPRxDataPkts64 OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of packets received on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 22 } + + wlanAPRxDataBytes64 OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of bytes received on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 23 } + + wlanAPTxDataPkts64 OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of packets transmitted on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 24 } + + wlanAPTxDataBytes64 OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of bytes transmitted on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 25 } + + wlanAPWiredRxErrorPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of error packets received from the controller on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 26 } + + wlanAPRxErrorPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of error packets received from stations on this BSSID. + " + ::= { wlsxWlanAPStatsEntry 27 } + +-- This table breaks down the AP statistics observed into different +-- rate categories. + + wlsxWlanAPRateStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlsxWlanAPRateStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This table contains all the AP Packet and Byte Counts + but represented in terms of rate categories. + " + + ::= { wlsxWlanAccessPointStatsGroup 2 } + + wlsxWlanAPRateStatsEntry OBJECT-TYPE + SYNTAX WlsxWlanAPRateStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Data rate based packet and byte count entry for an AP" + INDEX {wlanAPMacAddress, wlanAPRadioNumber, wlanAPBSSID} + ::= { wlsxWlanAPRateStatsTable 1 } + + WlsxWlanAPRateStatsEntry ::= + SEQUENCE { + wlanAPStatsTotPktsAt1Mbps Counter32, + wlanAPStatsTotBytesAt1Mbps Counter32, + wlanAPStatsTotPktsAt2Mbps Counter32, + wlanAPStatsTotBytesAt2Mbps Counter32, + wlanAPStatsTotPktsAt5Mbps Counter32, + wlanAPStatsTotBytesAt5Mbps Counter32, + wlanAPStatsTotPktsAt11Mbps Counter32, + wlanAPStatsTotBytesAt11Mbps Counter32, + wlanAPStatsTotPktsAt6Mbps Counter32, + wlanAPStatsTotBytesAt6Mbps Counter32, + wlanAPStatsTotPktsAt12Mbps Counter32, + wlanAPStatsTotBytesAt12Mbps Counter32, + wlanAPStatsTotPktsAt18Mbps Counter32, + wlanAPStatsTotBytesAt18Mbps Counter32, + wlanAPStatsTotPktsAt24Mbps Counter32, + wlanAPStatsTotBytesAt24Mbps Counter32, + wlanAPStatsTotPktsAt36Mbps Counter32, + wlanAPStatsTotBytesAt36Mbps Counter32, + wlanAPStatsTotPktsAt48Mbps Counter32, + wlanAPStatsTotBytesAt48Mbps Counter32, + wlanAPStatsTotPktsAt54Mbps Counter32, + wlanAPStatsTotBytesAt54Mbps Counter32, + wlanAPStatsTotPktsAt9Mbps Counter32, + wlanAPStatsTotBytesAt9Mbps Counter32 +-- wlanAPStatsTotPktsAtHT6dot5Mbps Counter32, +-- wlanAPStatsTotBytesAtHT6dot5Mbps Counter32, +-- wlanAPStatsTotPktsAtHT13Mbps Counter32, +-- wlanAPStatsTotBytesAtHT13Mbps Counter32, +-- wlanAPStatsTotPktsAtHT13dot5Mbps Counter32, +-- wlanAPStatsTotBytesAtHT13dot5Mbps Counter32, +-- wlanAPStatsTotPktsAtHT15Mbps Counter32, +-- wlanAPStatsTotBytesAtHT15Mbps Counter32, +-- wlanAPStatsTotPktsAtHT19dot5Mbps Counter32, +-- wlanAPStatsTotBytesAtHT19dot5Mbps Counter32, +-- wlanAPStatsTotPktsAtHT26Mbps Counter32, +-- wlanAPStatsTotBytesAtHT26Mbps Counter32, +-- wlanAPStatsTotPktsAtHT27Mbps Counter32, +-- wlanAPStatsTotBytesAtHT27Mbps Counter32, +-- wlanAPStatsTotPktsAtHT30Mbps Counter32, +-- wlanAPStatsTotBytesAtHT30Mbps Counter32, +-- wlanAPStatsTotPktsAtHT39Mbps Counter32, +-- wlanAPStatsTotBytesAtHT39Mbps Counter32, +-- wlanAPStatsTotPktsAtHT40dot5Mbps Counter32, +-- wlanAPStatsTotBytesAtHT40dot5Mbps Counter32, +-- wlanAPStatsTotPktsAtHT45Mbps Counter32, +-- wlanAPStatsTotBytesAtHT45Mbps Counter32, +-- wlanAPStatsTotPktsAtHT52Mbps Counter32, +-- wlanAPStatsTotBytesAtHT52Mbps Counter32, +-- wlanAPStatsTotPktsAtHT54Mbps Counter32, +-- wlanAPStatsTotBytesAtHT54Mbps Counter32, +-- wlanAPStatsTotPktsAtHT58dot5Mbps Counter32, +-- wlanAPStatsTotBytesAtHT58dot5Mbps Counter32, +-- wlanAPStatsTotPktsAtHT60Mbps Counter32, +-- wlanAPStatsTotBytesAtHT60Mbps Counter32, +-- wlanAPStatsTotPktsAtHT65Mbps Counter32, +-- wlanAPStatsTotBytesAtHT65Mbps Counter32, +-- wlanAPStatsTotPktsAtHT78Mbps Counter32, +-- wlanAPStatsTotBytesAtHT78Mbps Counter32, +-- wlanAPStatsTotPktsAtHT81Mbps Counter32, +-- wlanAPStatsTotBytesAtHT81Mbps Counter32, +-- wlanAPStatsTotPktsAtHT90Mbps Counter32, +-- wlanAPStatsTotBytesAtHT90Mbps Counter32, +-- wlanAPStatsTotPktsAtHT104Mbps Counter32, +-- wlanAPStatsTotBytesAtHT104Mbps Counter32, +-- wlanAPStatsTotPktsAtHT108Mbps Counter32, +-- wlanAPStatsTotBytesAtHT108Mbps Counter32, +-- wlanAPStatsTotPktsAtHT117Mbps Counter32, +-- wlanAPStatsTotBytesAtHT117Mbps Counter32, +-- wlanAPStatsTotPktsAtHT120Mbps Counter32, +-- wlanAPStatsTotBytesAtHT120Mbps Counter32, +-- wlanAPStatsTotPktsAtHT121dot5Mbps Counter32, +-- wlanAPStatsTotBytesAtHT121dot5Mbps Counter32, +-- wlanAPStatsTotPktsAtHT130Mbps Counter32, +-- wlanAPStatsTotBytesAtHT130Mbps Counter32, +-- wlanAPStatsTotPktsAtHT135Mbps Counter32, +-- wlanAPStatsTotBytesAtHT135Mbps Counter32, +-- wlanAPStatsTotPktsAtHT150Mbps Counter32, +-- wlanAPStatsTotBytesAtHT150Mbps Counter32, +-- wlanAPStatsTotPktsAtHT162Mbps Counter32, +-- wlanAPStatsTotBytesAtHT162Mbps Counter32, +-- wlanAPStatsTotPktsAtHT180Mbps Counter32, +-- wlanAPStatsTotBytesAtHT180Mbps Counter32, +-- wlanAPStatsTotPktsAtHT216Mbps Counter32, +-- wlanAPStatsTotBytesAtHT216Mbps Counter32, +-- wlanAPStatsTotPktsAtHT240Mbps Counter32, +-- wlanAPStatsTotBytesAtHT240Mbps Counter32, +-- wlanAPStatsTotPktsAtHT243Mbps Counter32, +-- wlanAPStatsTotBytesAtHT243Mbps Counter32, +-- wlanAPStatsTotPktsAtHT270Mbps Counter32, +-- wlanAPStatsTotBytesAtHT270Mbps Counter32, +-- wlanAPStatsTotPktsAtHT300Mbps Counter32, +-- wlanAPStatsTotBytesAtHT300Mbps Counter32 + } + + wlanAPStatsTotPktsAt1Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets observed + on this BSSID at 1Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 1 } + + wlanAPStatsTotBytesAt1Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Bytes observed + on this BSSID at 1Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 2 } + + wlanAPStatsTotPktsAt2Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets observed + on this BSSID at 2Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 3 } + + wlanAPStatsTotBytesAt2Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Bytes observed + on this BSSID at 2Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 4 } + + wlanAPStatsTotPktsAt5Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets observed + on this BSSID at 5Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 5 } + + wlanAPStatsTotBytesAt5Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Bytes observed + on this BSSID at 5Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 6 } + + wlanAPStatsTotPktsAt11Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets observed + on this BSSID at 11Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 7 } + + wlanAPStatsTotBytesAt11Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Bytes observed + on this BSSID at 11Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 8 } + + wlanAPStatsTotPktsAt6Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets observed + on this BSSID at 6Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 9 } + + wlanAPStatsTotBytesAt6Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Bytes observed + on this BSSID at 6Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 10 } + + wlanAPStatsTotPktsAt12Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets observed + on this BSSID at 12Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 11 } + + wlanAPStatsTotBytesAt12Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Bytes observed + on this BSSID at 12Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 12 } + + wlanAPStatsTotPktsAt18Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets observed + on this BSSID at 18Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 13 } + + wlanAPStatsTotBytesAt18Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Bytes observed + on this BSSID at 18Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 14 } + + wlanAPStatsTotPktsAt24Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets observed + on this BSSID at 24Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 15 } + + wlanAPStatsTotBytesAt24Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Bytes observed + on this BSSID at 24Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 16 } + + wlanAPStatsTotPktsAt36Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets observed + on this BSSID at 36Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 17 } + + wlanAPStatsTotBytesAt36Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Bytes observed + on this BSSID at 36Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 18 } + + wlanAPStatsTotPktsAt48Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets observed + on this BSSID at 48Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 19 } + + wlanAPStatsTotBytesAt48Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Bytes observed + on this BSSID at 48Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 20 } + + wlanAPStatsTotPktsAt54Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets observed + on this BSSID at 54Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 21 } + + wlanAPStatsTotBytesAt54Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Bytes observed + on this BSSID at 54Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 22 } + + wlanAPStatsTotPktsAt9Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets observed + on this BSSID at 9Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 23 } + + wlanAPStatsTotBytesAt9Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Bytes observed + on this BSSID at 9Mbps rate. + " + ::= { wlsxWlanAPRateStatsEntry 24 } + +-- wlanAPStatsTotPktsAtHT6dot5Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 6.5 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 25 } +-- +-- wlanAPStatsTotBytesAtHT6dot5Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 6.5 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 26 } +-- +-- wlanAPStatsTotPktsAtHT13Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 13.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 27 } +-- +-- wlanAPStatsTotBytesAtHT13Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 13.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 28 } +-- +-- wlanAPStatsTotPktsAtHT13dot5Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 13.5 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 29 } +-- +-- wlanAPStatsTotBytesAtHT13dot5Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 13.5 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 30 } +-- +-- wlanAPStatsTotPktsAtHT15Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 15.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 31 } +-- +-- wlanAPStatsTotBytesAtHT15Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 15.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 32 } +-- +-- wlanAPStatsTotPktsAtHT19dot5Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 19.5 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 33 } +-- +-- wlanAPStatsTotBytesAtHT19dot5Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 19.5 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 34 } +-- +-- wlanAPStatsTotPktsAtHT26Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 26.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 35 } +-- +-- wlanAPStatsTotBytesAtHT26Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 26.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 36 } +-- +-- wlanAPStatsTotPktsAtHT27Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 27.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 37 } +-- +-- wlanAPStatsTotBytesAtHT27Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 27.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 38 } +-- +-- wlanAPStatsTotPktsAtHT30Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 30.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 39 } +-- +-- wlanAPStatsTotBytesAtHT30Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 30.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 40 } +-- +-- wlanAPStatsTotPktsAtHT39Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 39.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 41 } +-- +-- wlanAPStatsTotBytesAtHT39Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 39.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 42 } +-- +-- wlanAPStatsTotPktsAtHT40dot5Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 40.5 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 43 } +-- +-- wlanAPStatsTotBytesAtHT40dot5Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 40.5 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 44 } +-- +-- wlanAPStatsTotPktsAtHT45Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 45.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 45 } +-- +-- wlanAPStatsTotBytesAtHT45Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 45.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 46 } +-- +-- wlanAPStatsTotPktsAtHT52Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 52.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 47 } +-- +-- wlanAPStatsTotBytesAtHT52Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 52.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 48 } +-- +-- wlanAPStatsTotPktsAtHT54Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 54.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 49 } +-- +-- wlanAPStatsTotBytesAtHT54Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 54.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 50 } +-- +-- wlanAPStatsTotPktsAtHT58dot5Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 58.5 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 51 } +-- +-- wlanAPStatsTotBytesAtHT58dot5Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 58.5 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 52 } +-- +-- wlanAPStatsTotPktsAtHT60Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 60.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 53 } +-- +-- wlanAPStatsTotBytesAtHT60Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 60.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 54 } +-- +-- wlanAPStatsTotPktsAtHT65Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 65.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 55 } +-- +-- wlanAPStatsTotBytesAtHT65Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 65.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 56 } +-- +-- wlanAPStatsTotPktsAtHT78Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 78.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 57 } +-- +-- wlanAPStatsTotBytesAtHT78Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 78.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 58 } +-- +-- wlanAPStatsTotPktsAtHT81Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 81.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 59 } +-- +-- wlanAPStatsTotBytesAtHT81Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 81.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 60 } +-- +-- wlanAPStatsTotPktsAtHT90Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 90.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 61 } +-- +-- wlanAPStatsTotBytesAtHT90Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 90.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 62 } +-- +-- wlanAPStatsTotPktsAtHT104Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 104.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 63 } +-- +-- wlanAPStatsTotBytesAtHT104Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 104.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 64 } +-- +-- wlanAPStatsTotPktsAtHT108Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 108.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 65 } +-- +-- wlanAPStatsTotBytesAtHT108Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 108.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 66 } +-- +-- wlanAPStatsTotPktsAtHT117Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 117.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 67 } +-- +-- wlanAPStatsTotBytesAtHT117Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 117.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 68 } +-- +-- wlanAPStatsTotPktsAtHT120Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 120.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 69 } +-- +-- wlanAPStatsTotBytesAtHT120Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 120.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 70 } +-- +-- wlanAPStatsTotPktsAtHT121dot5Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 121.5 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 71 } +-- +-- wlanAPStatsTotBytesAtHT121dot5Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 121.5 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 72 } +-- +-- wlanAPStatsTotPktsAtHT130Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 130.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 73 } +-- +-- wlanAPStatsTotBytesAtHT130Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 130.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 74 } +-- +-- wlanAPStatsTotPktsAtHT135Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 135.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 75 } +-- +-- wlanAPStatsTotBytesAtHT135Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 135.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 76 } +-- +-- wlanAPStatsTotPktsAtHT150Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 150.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 77 } +-- +-- wlanAPStatsTotBytesAtHT150Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 150.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 78 } +-- +-- wlanAPStatsTotPktsAtHT162Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 162.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 79 } +-- +-- wlanAPStatsTotBytesAtHT162Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 162.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 80 } +-- +-- wlanAPStatsTotPktsAtHT180Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 180.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 81 } +-- +-- wlanAPStatsTotBytesAtHT180Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 180.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 82 } +-- +-- wlanAPStatsTotPktsAtHT216Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 216.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 83 } +-- +-- wlanAPStatsTotBytesAtHT216Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 216.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 84 } +-- +-- wlanAPStatsTotPktsAtHT240Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 240.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 85 } +-- +-- wlanAPStatsTotBytesAtHT240Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 240.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 86 } +-- +-- wlanAPStatsTotPktsAtHT243Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 243.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 87 } +-- +-- wlanAPStatsTotBytesAtHT243Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 243.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 88 } +-- +-- wlanAPStatsTotPktsAtHT270Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 270.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 89 } +-- +-- wlanAPStatsTotBytesAtHT270Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 270.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 90 } +-- +-- wlanAPStatsTotPktsAtHT300Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of packets observed +-- on this BSSID at the HT 300.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 91 } +-- +-- wlanAPStatsTotBytesAtHT300Mbps OBJECT-TYPE +-- SYNTAX Counter32 +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- " +-- This attribute indicates the total number of bytes observed +-- on this BSSID at the HT 300.0 rate. +-- " +-- ::= { wlsxWlanAPRateStatsEntry 92 } + +-- This table breaks down the BSSID statistics observed based on the +-- Destination Address Types. + + wlsxWlanAPDATypeStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlsxWlanAPDATypeStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This table contains all the per BSSID Packet and Byte Counts + but broken down in terms of Destination Address Type. + " + ::= { wlsxWlanAccessPointStatsGroup 3 } + + wlsxWlanAPDATypeStatsEntry OBJECT-TYPE + SYNTAX WlsxWlanAPDATypeStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Destination Address based packet and byte count entry for an AP" + INDEX {wlanAPMacAddress, wlanAPRadioNumber, wlanAPBSSID} + ::= { wlsxWlanAPDATypeStatsTable 1 } + + WlsxWlanAPDATypeStatsEntry ::= + SEQUENCE { + wlanAPStatsTotDABroadcastPkts Counter32 , + wlanAPStatsTotDABroadcastBytes Counter32 , + wlanAPStatsTotDAMulticastPkts Counter32 , + wlanAPStatsTotDAMulticastBytes Counter32 , + wlanAPStatsTotDAUnicastPkts Counter32 , + wlanAPStatsTotDAUnicastBytes Counter32 + + } + + wlanAPStatsTotDABroadcastPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Broadcast packets + observed on this BSSID. + " + ::= { wlsxWlanAPDATypeStatsEntry 1 } + + wlanAPStatsTotDABroadcastBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Broadcast Bytes + observed on this BSSID. + " + ::= { wlsxWlanAPDATypeStatsEntry 2 } + + wlanAPStatsTotDAMulticastPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Multicast packets + observed on this BSSID. + " + ::= { wlsxWlanAPDATypeStatsEntry 3 } + + wlanAPStatsTotDAMulticastBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Multicast Bytes + observed on this BSSID. + " + ::= { wlsxWlanAPDATypeStatsEntry 4 } + + wlanAPStatsTotDAUnicastPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Unicast packets + observed on this BSSID. + " + ::= { wlsxWlanAPDATypeStatsEntry 5 } + + wlanAPStatsTotDAUnicastBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Unicast Bytes + observed on this BSSID. + " + ::= { wlsxWlanAPDATypeStatsEntry 6 } + +-- This table breaks down the BSSID statistics observed based on the +-- the Type of the Packet. + + wlsxWlanAPFrameTypeStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlsxWlanAPFrameTypeStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This table contains all the per BSSID Packet and Byte Counts + but broken down into different Frame Types. + " + ::= { wlsxWlanAccessPointStatsGroup 4 } + + wlsxWlanAPFrameTypeStatsEntry OBJECT-TYPE + SYNTAX WlsxWlanAPFrameTypeStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Frame Type based packet and byte count entry for an AP" + INDEX {wlanAPMacAddress, wlanAPRadioNumber, wlanAPBSSID} + ::= { wlsxWlanAPFrameTypeStatsTable 1 } + + WlsxWlanAPFrameTypeStatsEntry ::= + SEQUENCE { + wlanAPStatsTotMgmtPkts Counter32 , + wlanAPStatsTotMgmtBytes Counter32 , + wlanAPStatsTotCtrlPkts Counter32 , + wlanAPStatsTotCtrlBytes Counter32 , + wlanAPStatsTotDataPkts Counter32 , + wlanAPStatsTotDataBytes Counter32 + + } + + wlanAPStatsTotMgmtPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Management packets + observed on this BSSID. + " + ::= { wlsxWlanAPFrameTypeStatsEntry 1 } + + wlanAPStatsTotMgmtBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Management Bytes + observed on this BSSID. + " + ::= { wlsxWlanAPFrameTypeStatsEntry 2 } + + wlanAPStatsTotCtrlPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Control packets + observed on this BSSID. + " + ::= { wlsxWlanAPFrameTypeStatsEntry 3 } + + wlanAPStatsTotCtrlBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Control Bytes + observed on this BSSID. + " + ::= { wlsxWlanAPFrameTypeStatsEntry 4 } + + wlanAPStatsTotDataPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Data packets + observed on this BSSID. + " + ::= { wlsxWlanAPFrameTypeStatsEntry 5 } + + wlanAPStatsTotDataBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of Data Bytes + observed on this BSSID. + " + ::= { wlsxWlanAPFrameTypeStatsEntry 6 } + +-- This table breaks down the BSSID statistics observed into packet size +-- buckets. + + wlsxWlanAPPktSizeStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlsxWlanAPPktSizeStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This table contains all the per BSSID Packet Count + but broken down into different Packet Sizes. + " + ::= { wlsxWlanAccessPointStatsGroup 5 } + + wlsxWlanAPPktSizeStatsEntry OBJECT-TYPE + SYNTAX WlsxWlanAPPktSizeStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Packet Size based packet count entry for a BSSID" + INDEX {wlanAPMacAddress, wlanAPRadioNumber, wlanAPBSSID} + ::= { wlsxWlanAPPktSizeStatsTable 1 } + + WlsxWlanAPPktSizeStatsEntry ::= + SEQUENCE { + wlanAPStatsPkts63Bytes Counter32 , + wlanAPStatsPkts64To127 Counter32 , + wlanAPStatsPkts128To255 Counter32 , + wlanAPStatsPkts256To511 Counter32 , + wlanAPStatsPkts512To1023 Counter32 , + wlanAPStatsPkts1024To1518 Counter32 + + } + + wlanAPStatsPkts63Bytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets that were + less than 64 bytes long. + " + ::= { wlsxWlanAPPktSizeStatsEntry 1 } + + wlanAPStatsPkts64To127 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets that were + between 64 and 127 bytes long. + " + ::= { wlsxWlanAPPktSizeStatsEntry 2 } + + wlanAPStatsPkts128To255 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets that were + between 128 and 255 bytes long. + " + ::= { wlsxWlanAPPktSizeStatsEntry 3 } + + wlanAPStatsPkts256To511 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets that were + between 256 and 511 bytes long. + " + ::= { wlsxWlanAPPktSizeStatsEntry 4 } + + wlanAPStatsPkts512To1023 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets that were + between 512 and 1023 bytes long. + " + ::= { wlsxWlanAPPktSizeStatsEntry 5 } + + wlanAPStatsPkts1024To1518 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total number of packets that were + between 1024 and 1518 bytes long. + " + ::= { wlsxWlanAPPktSizeStatsEntry 6 } + + +-- AP Chan Stats table + + wlsxWlanAPChStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanAPChStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This Table lists the Channel statistics of all the Access Points + connected to the controller. + " + ::= { wlsxWlanAccessPointStatsGroup 6 } + + wlsxWlanAPChStatsEntry OBJECT-TYPE + SYNTAX WlanAPChStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Access Point Channel Stats entry" + INDEX {wlanAPMacAddress, wlanAPRadioNumber} + ::= { wlsxWlanAPChStatsTable 1 } + + WlanAPChStatsEntry ::= + SEQUENCE { + wlanAPChannelNumber INTEGER, + wlanAPChNumStations Integer32, + wlanAPChTotPkts Counter32, + wlanAPChTotBytes Counter32, + wlanAPChTotRetryPkts Counter32, + wlanAPChTotFragmentedPkts Counter32, + wlanAPChTotPhyErrPkts Counter32, + wlanAPChTotMacErrPkts Counter32, + wlanAPChNoise Integer32, + wlanAPChCoverageIndex Integer32, + wlanAPChInterferenceIndex Integer32, + wlanAPChFrameRetryRate Integer32, + wlanAPChFrameLowSpeedRate Integer32, + wlanAPChFrameNonUnicastRate Integer32, + wlanAPChFrameFragmentationRate Integer32, + wlanAPChFrameBandwidthRate Integer32, + wlanAPChFrameRetryErrorRate Integer32, + wlanAPChBusyRate Integer32, + wlanAPChNumAPs Integer32, + wlanAPChFrameReceiveErrorRate Integer32, + wlanAPChTransmittedFragmentCount Counter32, + wlanAPChMulticastTransmittedFrameCount Counter32, + wlanAPChFailedCount Counter32, + wlanAPChRetryCount Counter32, + wlanAPChMultipleRetryCount Counter32, + wlanAPChFrameDuplicateCount Counter32, + wlanAPChRTSSuccessCount Counter32, + wlanAPChRTSFailureCount Counter32, + wlanAPChACKFailureCount Counter32, + wlanAPChReceivedFragmentCount Counter32, + wlanAPChMulticastReceivedFrameCount Counter32, + wlanAPChFCSErrorCount Counter32, + wlanAPChTransmittedFrameCount Counter32, + wlanAPChWEPUndecryptableCount Counter32, + wlanAPChRxUtilization INTEGER, + wlanAPChTxUtilization INTEGER, + wlanAPChUtilization INTEGER + } + + wlanAPChannelNumber OBJECT-TYPE + SYNTAX INTEGER(1..165) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The channel the AP is currently using. + " + ::= { wlsxWlanAPChStatsEntry 1 } + + wlanAPChNumStations OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of stations using this + channel. + " + ::= { wlsxWlanAPChStatsEntry 2 } + + wlanAPChTotPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total packets observed on this + channel. + " + ::= { wlsxWlanAPChStatsEntry 3 } + + wlanAPChTotBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total Bytes observed on this + channel. + " + ::= { wlsxWlanAPChStatsEntry 4 } + + wlanAPChTotRetryPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total Retry Packets observed on this + channel. + " + ::= { wlsxWlanAPChStatsEntry 5 } + + wlanAPChTotFragmentedPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total Fragmented Packets observed on + this channel. + " + ::= { wlsxWlanAPChStatsEntry 6 } + + wlanAPChTotPhyErrPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total Physical Error Packets observed + on this channel. + " + ::= { wlsxWlanAPChStatsEntry 7 } + + wlanAPChTotMacErrPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total Mac errors packets observed on + this channel. + " + ::= { wlsxWlanAPChStatsEntry 8 } + + wlanAPChNoise OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the noise observed on + this channel. + " + ::= { wlsxWlanAPChStatsEntry 9 } + + wlanAPChCoverageIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the coverage provided by the AP on + this channel. + " + ::= { wlsxWlanAPChStatsEntry 10 } + + wlanAPChInterferenceIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the interference + observed on this channel. + " + ::= { wlsxWlanAPChStatsEntry 11 } + + wlanAPChFrameRetryRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of retry + packets as a percentage of the total packets + transmitted and received on this channel. + " + ::= { wlsxWlanAPChStatsEntry 12 } + + wlanAPChFrameLowSpeedRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of low data rate (<= 18Mbps for A/G bands and <=2Mbps + for B band) packets as a percentage of the total packets + transmitted and received on this channel + " + ::= { wlsxWlanAPChStatsEntry 13 } + + wlanAPChFrameNonUnicastRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of broadcast and multicast + packets as a percentage of the total packets + transmitted on this channel. + " + ::= { wlsxWlanAPChStatsEntry 14 } + + wlanAPChFrameFragmentationRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of fragments + as a percentage of the total packets + transmitted on this channel + " + ::= { wlsxWlanAPChStatsEntry 15 } + + wlanAPChFrameBandwidthRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The bandwidth of this channel in Kbps. + " + ::= { wlsxWlanAPChStatsEntry 16 } + + wlanAPChFrameRetryErrorRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + " + The number of error packets + as a percentage of the total packets + received on this channel. + " + ::= { wlsxWlanAPChStatsEntry 17 } + + wlanAPChBusyRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the busy + this channel is. + " + ::= { wlsxWlanAPChStatsEntry 18 } + + wlanAPChNumAPs OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Access Points + observed on this channel. + " + ::= { wlsxWlanAPChStatsEntry 19 } + + wlanAPChFrameReceiveErrorRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of error packets + as a percentage of the total packets + received on this channel. + " + ::= { wlsxWlanAPChStatsEntry 20 } + + wlanAPChTransmittedFragmentCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This counter shall be incremented for an acknowledged MPDU + with an individual address in the address 1 field or an MPDU + with a multicast address in the address 1 field of type Data + or Management. + " + ::= { wlsxWlanAPChStatsEntry 21 } + + wlanAPChMulticastTransmittedFrameCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This counter shall increment only when the multicast bit + is set in the destination MAC address of a successfully + transmitted MSDU. When operating as a STA in an ESS, where + these frames are directed to the AP, this implies having + received an acknowledgment to all associated MPDUs. + " + ::= { wlsxWlanAPChStatsEntry 22 } + + wlanAPChFailedCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This counter shall increment when an MSDU is not transmitted + successfully due to the number of transmit attempts exceeding + either the dot11ShortRetryLimit or dot11LongRetryLimit. + " + ::= { wlsxWlanAPChStatsEntry 23 } + + wlanAPChRetryCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This counter shall increment when an MSDU is successfully + transmitted after one or more retransmissions. + " + ::= { wlsxWlanAPChStatsEntry 24 } + + wlanAPChMultipleRetryCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This counter shall increment when an MSDU is successfully + transmitted after more than one retransmission. + " + ::= { wlsxWlanAPChStatsEntry 25 } + + wlanAPChFrameDuplicateCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This counter shall increment when a frame is received + that the Sequence Control field indicates is a + duplicate. + " + ::= { wlsxWlanAPChStatsEntry 26 } + + wlanAPChRTSSuccessCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This counter shall increment when a CTS is received in + response to an RTS. + " + ::= { wlsxWlanAPChStatsEntry 27 } + + wlanAPChRTSFailureCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This counter shall increment when a CTS is not received in + response to an RTS. + " + ::= { wlsxWlanAPChStatsEntry 28 } + + wlanAPChACKFailureCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This counter shall increment when an ACK is not received + when expected. + " + ::= { wlsxWlanAPChStatsEntry 29 } + + wlanAPChReceivedFragmentCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This counter shall be incremented for each successfully + received MPDU of type Data or Management. + " + ::= { wlsxWlanAPChStatsEntry 30 } + + wlanAPChMulticastReceivedFrameCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This counter shall increment when a MSDU is received + with the multicast bit set in the destination + MAC address. + " + ::= { wlsxWlanAPChStatsEntry 31 } + + wlanAPChFCSErrorCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This counter shall increment when an FCS error is + detected in a received MPDU. + " + ::= { wlsxWlanAPChStatsEntry 32 } + + wlanAPChTransmittedFrameCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This counter shall increment for each successfully transmitted + MSDU. + " + ::= { wlsxWlanAPChStatsEntry 33 } + + wlanAPChWEPUndecryptableCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This counter shall increment when a frame is received with the + Protected Frame subfield of the Frame Control field set to one and + the WEPOn value for the key mapped to the transmitter's MAC address + indicates that the frame should not have been encrypted or that frame + is discarded due to the receiving STA not implementing the privacy + option. + " + ::= { wlsxWlanAPChStatsEntry 34 } + + wlanAPChRxUtilization OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This is the percentage of time spent by the radio + in receiving packets. + " + ::= { wlsxWlanAPChStatsEntry 35 } + + wlanAPChTxUtilization OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This is the percentage of time spent by the radio + in transmitting packets. + " + ::= { wlsxWlanAPChStatsEntry 36 } + + wlanAPChUtilization OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This is the percentage of time the channel is busy. + " + ::= { wlsxWlanAPChStatsEntry 37 } + +-- AP Wired Stats table + + wlsxWlanAPWiredStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanAPWiredStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This Table lists the Wired statistics of all the Access Points + connected to the controller. + " + ::= { wlsxWlanAccessPointStatsGroup 7 } + + wlsxWlanAPWiredStatsEntry OBJECT-TYPE + SYNTAX WlanAPWiredStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Access Point Wired Stats entry" + INDEX {wlanAPMacAddress} + ::= { wlsxWlanAPWiredStatsTable 1 } + + WlanAPWiredStatsEntry ::= + SEQUENCE { + wlanAPWiredRxPkts Counter32, + wlanAPWiredRxDroppedPkts Counter32, + wlanAPWiredRxBytes Counter32, + wlanAPWiredTxBytes Counter32, + wlanAPWiredRxRate Gauge32, + wlanAPWiredTxRate Gauge32 + } + + wlanAPWiredRxPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total packets received from the + AP wired side. + " + ::= { wlsxWlanAPWiredStatsEntry 1 } + + wlanAPWiredRxDroppedPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total dropped packets received + from the AP wired side. + " + ::= { wlsxWlanAPWiredStatsEntry 2 } + + wlanAPWiredRxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total bytes of correct packets + received from the AP wired side. + " + ::= { wlsxWlanAPWiredStatsEntry 3 } + + wlanAPWiredTxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total bytes transmitted from + the AP wired side. + " + ::= { wlsxWlanAPWiredStatsEntry 4 } + + wlanAPWiredRxRate OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the data rate (kbyte/s) + received from AP wired side in sampling interval. + " + ::= { wlsxWlanAPWiredStatsEntry 5 } + + wlanAPWiredTxRate OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the data rate (kbyte/s) + transmitted from AP wired side in sampling interval. + " + ::= { wlsxWlanAPWiredStatsEntry 6 } + +-- AP ESSID Stats table + + wlsxWlanAPESSIDStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanAPESSIDStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This Table lists the ESSID statistics of all the Access Points + connected to the controller. + " + ::= { wlsxWlanAccessPointStatsGroup 8 } + + wlsxWlanAPESSIDStatsEntry OBJECT-TYPE + SYNTAX WlanAPESSIDStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Access Point ESSID Stats entry" + INDEX {wlanAPMacAddress, wlanESSID} + ::= { wlsxWlanAPESSIDStatsTable 1 } + + WlanAPESSIDStatsEntry ::= + SEQUENCE { + wlanAPESSIDWirelessRxBytes Counter32, + wlanAPESSIDWirelessTxBytes Counter32, + wlanAPESSIDWiredRxBytes Counter32, + wlanAPESSIDWiredTxBytes Counter32 + } + + wlanAPESSIDWirelessRxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total bytes of correct packets + received from the AP ESSID wireless side. + " + ::= { wlsxWlanAPESSIDStatsEntry 1 } + + wlanAPESSIDWirelessTxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total bytes transmitted + from the AP ESSID wireless side. + " + ::= { wlsxWlanAPESSIDStatsEntry 2 } + + wlanAPESSIDWiredRxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total bytes of correct packets + received from the AP ESSID wired side. + " + ::= { wlsxWlanAPESSIDStatsEntry 3 } + + wlanAPESSIDWiredTxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total bytes transmitted from + the AP ESSID wired side. + " + ::= { wlsxWlanAPESSIDStatsEntry 4 } + +-- AP Radio Stats table + + wlsxWlanAPRadioStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanAPRadioStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This Table lists the Radio statistics of all the Access Points + connected to the controller. + " + ::= { wlsxWlanAccessPointStatsGroup 9 } + + wlsxWlanAPRadioStatsEntry OBJECT-TYPE + SYNTAX WlanAPRadioStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Access Point Radio Stats entry" + INDEX {wlanAPMacAddress, wlanAPRadioNumber} + ::= { wlsxWlanAPRadioStatsTable 1 } + + WlanAPRadioStatsEntry ::= + SEQUENCE { + wlanAPRadioRxPkts Counter32, + wlanAPRadioRxBytes Counter32, + wlanAPRadioTxPkts Counter32, + wlanAPRadioTxBytes Counter32, + wlanAPRadioTxDroppedPkts Counter32, + wlanAPRadioTxErrorPkts Counter32, + wlanAPRadioRxRate Gauge32, + wlanAPRadioTxRate Gauge32, + wlanApRadioAssocReqCount Counter32, + wlanApRadioAssocReqSuccCount Counter32, + wlanApRadioReAssocReqCount Counter32, + wlanApRadioReAssocReqSuccCount Counter32, + wlanAPRadioStationDuration Integer32, + wlanAPRadioAssocSuccPercent Gauge32, + wlanAPRadioTxDataBytes Counter32 + } + + wlanAPRadioRxPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total packets transmitted + from the AP radio wireless side. + " + ::= { wlsxWlanAPRadioStatsEntry 1 } + + wlanAPRadioRxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total correct bytes + received from the AP radio wireless side. + " + ::= { wlsxWlanAPRadioStatsEntry 2 } + + wlanAPRadioTxPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total packets + transmitted from the AP radio wireless side. + " + ::= { wlsxWlanAPRadioStatsEntry 3 } + + wlanAPRadioTxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total bytes + transmitted from the AP radio wireless side. + " + ::= { wlsxWlanAPRadioStatsEntry 4 } + + wlanAPRadioTxDroppedPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the dropped packets transmitted + from the AP radio wireless side. + " + ::= { wlsxWlanAPRadioStatsEntry 5 } + + wlanAPRadioTxErrorPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the error packets + transmitted from the AP radio wireless side. + " + ::= { wlsxWlanAPRadioStatsEntry 6 } + + wlanAPRadioRxRate OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the data rate (kbyte/s) + received from AP radio wireless side in sampling interval. + " + ::= { wlsxWlanAPRadioStatsEntry 7 } + + wlanAPRadioTxRate OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the data rate (kbyte/s) + transmitted from AP radio wireless side in sampling interval. + " + ::= { wlsxWlanAPRadioStatsEntry 8 } + + wlanApRadioAssocReqCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This attribute indicates the times of associate request on this + radio." + ::= { wlsxWlanAPRadioStatsEntry 9 } + + wlanApRadioAssocReqSuccCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This attribute indicates the times of successful associate request + on this radio." + ::= { wlsxWlanAPRadioStatsEntry 10 } + + wlanApRadioReAssocReqCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This attribute indicates the times of re-associate request on this + radio." + ::= { wlsxWlanAPRadioStatsEntry 11 } + + wlanApRadioReAssocReqSuccCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This attribute indicates the times of successful re-associate + request on this radio. + " + ::= { wlsxWlanAPRadioStatsEntry 12 } + + wlanAPRadioStationDuration OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total occupied duration, which is + the total duration of user connecting. + " + ::= { wlsxWlanAPRadioStatsEntry 13 } + + wlanAPRadioAssocSuccPercent OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The Association Success Percent. + " + ::= { wlsxWlanAPRadioStatsEntry 14 } + + wlanAPRadioTxDataBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total data bytes + transmitted from the AP radio wireless side. + " + ::= { wlsxWlanAPRadioStatsEntry 15 } + +-- wlsxWlanStationStatsGroup contains all the statistics observed by different +-- Air Monitors attached to this controller. +-- Station Statistics are observed by the Air Monitor for that +-- specific Station. + +-- Station Statistics are grouped into Generic, +-- Rate, Destination Address and Frame Type Stats. + +-- Station Statistics Group contains all the statistics related to +-- a Station. + +-- wlsxWlanStationStatsTable will contain all the aggregate statistics collected +-- for a Station + + wlsxWlanStationStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanStationStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This Table lists statistics of all the wireless stations + associated with an AP connected to this controller. + " + ::= { wlsxWlanStationStatsGroup 1} + + wlsxWlanStationStatsEntry OBJECT-TYPE + SYNTAX WlanStationStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Station Stats Entry" + INDEX {wlanStaPhyAddress} + ::= { wlsxWlanStationStatsTable 1 } + + WlanStationStatsEntry ::= + SEQUENCE { + wlanStaChannelNum Unsigned32, + wlanStaTxPkts Counter32, + wlanStaTxBytes Counter32, + wlanStaRxPkts Counter32, + wlanStaRxBytes Counter32, + wlanStaTxBCastPkts Counter32, + wlanStaRxBCastBytes Counter32, + wlanStaTxMCastPkts Counter32, + wlanStaRxMCastBytes Counter32, + wlanStaDataPkts Counter32, + wlanStaCtrlPkts Counter32, + wlanStaNumAssocRequests Counter32, + wlanStaNumAuthRequests Counter32, + wlanStaTxDeauthentications Counter32, + wlanStaRxDeauthentications Counter32, + wlanStaFrameRetryRate Integer32, + wlanStaFrameLowSpeedRate Integer32, + wlanStaFrameNonUnicastRate Integer32, + wlanStaFrameFragmentationRate Integer32, + wlanStaFrameBandwidthRate Integer32, + wlanStaFrameRetryErrorRate Integer32, + wlanStaFrameReceiveErrorRate Integer32, + wlanStaTxBCastBytes Counter32, + wlanStaTxMCastBytes Counter32, + wlanStaTxBytes64 Counter64, + wlanStaRxBytes64 Counter64 + } + + wlanStaChannelNum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The channel the station is currently using. + " + ::= { wlsxWlanStationStatsEntry 1 } + + wlanStaTxPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of packets transmitted by this station. + " + ::= { wlsxWlanStationStatsEntry 2 } + + wlanStaTxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of bytes transmitted by this station. + " + ::= { wlsxWlanStationStatsEntry 3 } + + wlanStaRxPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of packets received by this station. + " + ::= { wlsxWlanStationStatsEntry 4 } + + wlanStaRxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of bytes received by this station. + " + ::= { wlsxWlanStationStatsEntry 5 } + + wlanStaTxBCastPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of broadcast packets transmitted by this station. + " + ::= { wlsxWlanStationStatsEntry 6 } + + wlanStaRxBCastBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + " + The number of broadcast bytes transmitted by this station. + " + ::= { wlsxWlanStationStatsEntry 7 } + + wlanStaTxMCastPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of multicast packets transmitted by this station. + " + ::= { wlsxWlanStationStatsEntry 8 } + + wlanStaRxMCastBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + " + The number of multicast bytes transmitted by this station. + " + ::= { wlsxWlanStationStatsEntry 9 } + + wlanStaDataPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The total number of Data packets transmitted by this station. + " + ::= { wlsxWlanStationStatsEntry 10 } + + wlanStaCtrlPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The total number of Control packets transmitted by this station. + " + ::= { wlsxWlanStationStatsEntry 11 } + + wlanStaNumAssocRequests OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of Association requests transmitted by this station. + " + ::= { wlsxWlanStationStatsEntry 12 } + + wlanStaNumAuthRequests OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of Authentication requests transmitted by this station. + " + ::= { wlsxWlanStationStatsEntry 13 } + + wlanStaTxDeauthentications OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of Deauthentication frames transmitted by this station. + " + ::= { wlsxWlanStationStatsEntry 14 } + + wlanStaRxDeauthentications OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of Deauthentication frames received by this station. + " + ::= { wlsxWlanStationStatsEntry 15 } + + wlanStaFrameRetryRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of retry + packets as a percentage of the total packets + transmitted and received by this station. + " + ::= { wlsxWlanStationStatsEntry 16 } + + wlanStaFrameLowSpeedRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of low data rate (<= 18Mbps for A/G bands and <=2Mbps + for B band) packets as a percentage of the total packets + transmitted and received by this station. + " + ::= { wlsxWlanStationStatsEntry 17 } + + wlanStaFrameNonUnicastRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of broadcast and multicast + packets as a percentage of the total packets + transmitted by this station. + " + ::= { wlsxWlanStationStatsEntry 18 } + + wlanStaFrameFragmentationRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of fragments + as a percentage of the total packets + transmitted by this station. + " + ::= { wlsxWlanStationStatsEntry 19 } + + wlanStaFrameBandwidthRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The bandwidth of this station in Kbps. + " + ::= { wlsxWlanStationStatsEntry 20 } + + wlanStaFrameRetryErrorRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + " + The number of error packets + as a percentage of the total packets + received by this station. + " + ::= { wlsxWlanStationStatsEntry 21 } + + wlanStaFrameReceiveErrorRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of error packets + as a percentage of the total packets + received by this station. + " + ::= { wlsxWlanStationStatsEntry 22 } + + wlanStaTxBCastBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of broadcast bytes transmitted by this station. + " + ::= { wlsxWlanStationStatsEntry 23 } + + wlanStaTxMCastBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of multicast bytes transmitted by this station. + " + ::= { wlsxWlanStationStatsEntry 24 } + + wlanStaTxBytes64 OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of bytes transmitted by this station, 64-bit value + " + ::= { wlsxWlanStationStatsEntry 25 } + + wlanStaRxBytes64 OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The number of bytes received by this station, 64-bit value + " + ::= { wlsxWlanStationStatsEntry 26 } + + +-- This table breaks down the Station statistics into different +-- rate categories. + + wlsxWlanStaRateStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlsxWlanStaRateStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This table contains all the Packet and Byte Counts for a station + represented in terms of rate categories. + " + ::= { wlsxWlanStationStatsGroup 2} + + wlsxWlanStaRateStatsEntry OBJECT-TYPE + SYNTAX WlsxWlanStaRateStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Data rate based packet and byte count entry for a station" + INDEX {wlanStaPhyAddress} + ::= { wlsxWlanStaRateStatsTable 1 } + + WlsxWlanStaRateStatsEntry ::= + SEQUENCE { + wlanStaTxPktsAt1Mbps Counter32, + wlanStaTxBytesAt1Mbps Counter32, + wlanStaTxPktsAt2Mbps Counter32, + wlanStaTxBytesAt2Mbps Counter32, + wlanStaTxPktsAt5Mbps Counter32, + wlanStaTxBytesAt5Mbps Counter32, + wlanStaTxPktsAt11Mbps Counter32, + wlanStaTxBytesAt11Mbps Counter32, + wlanStaTxPktsAt6Mbps Counter32, + wlanStaTxBytesAt6Mbps Counter32, + wlanStaTxPktsAt12Mbps Counter32, + wlanStaTxBytesAt12Mbps Counter32, + wlanStaTxPktsAt18Mbps Counter32, + wlanStaTxBytesAt18Mbps Counter32, + wlanStaTxPktsAt24Mbps Counter32, + wlanStaTxBytesAt24Mbps Counter32, + wlanStaTxPktsAt36Mbps Counter32, + wlanStaTxBytesAt36Mbps Counter32, + wlanStaTxPktsAt48Mbps Counter32, + wlanStaTxBytesAt48Mbps Counter32, + wlanStaTxPktsAt54Mbps Counter32, + wlanStaTxBytesAt54Mbps Counter32, + wlanStaRxPktsAt1Mbps Counter32, + wlanStaRxBytesAt1Mbps Counter32, + wlanStaRxPktsAt2Mbps Counter32, + wlanStaRxBytesAt2Mbps Counter32, + wlanStaRxPktsAt5Mbps Counter32, + wlanStaRxBytesAt5Mbps Counter32, + wlanStaRxPktsAt11Mbps Counter32, + wlanStaRxBytesAt11Mbps Counter32, + wlanStaRxPktsAt6Mbps Counter32, + wlanStaRxBytesAt6Mbps Counter32, + wlanStaRxPktsAt12Mbps Counter32, + wlanStaRxBytesAt12Mbps Counter32, + wlanStaRxPktsAt18Mbps Counter32, + wlanStaRxBytesAt18Mbps Counter32, + wlanStaRxPktsAt24Mbps Counter32, + wlanStaRxBytesAt24Mbps Counter32, + wlanStaRxPktsAt36Mbps Counter32, + wlanStaRxBytesAt36Mbps Counter32, + wlanStaRxPktsAt48Mbps Counter32, + wlanStaRxBytesAt48Mbps Counter32, + wlanStaRxPktsAt54Mbps Counter32, + wlanStaRxBytesAt54Mbps Counter32, + wlanStaTxPktsAt9Mbps Counter32, + wlanStaTxBytesAt9Mbps Counter32, + wlanStaRxPktsAt9Mbps Counter32, + wlanStaRxBytesAt9Mbps Counter32 + } + + wlanStaTxPktsAt1Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Transmitted by the + station at 1Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 1 } + + wlanStaTxBytesAt1Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Transmitted by the + station at 1Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 2 } + + wlanStaTxPktsAt2Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Transmitted by the + station at 2Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 3 } + + wlanStaTxBytesAt2Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Transmitted by the + station at 2Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 4 } + + wlanStaTxPktsAt5Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Transmitted by the + station at 5Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 5 } + + wlanStaTxBytesAt5Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Transmitted by the + station at 5Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 6 } + + wlanStaTxPktsAt11Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Transmitted by the + station at 11Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 7 } + + wlanStaTxBytesAt11Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Transmitted by the + station at 11Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 8 } + + wlanStaTxPktsAt6Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Transmitted by the + station at 6Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 9 } + + wlanStaTxBytesAt6Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Transmitted by the + station at 6Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 10 } + + wlanStaTxPktsAt12Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Transmitted by the + station at 12Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 11 } + + wlanStaTxBytesAt12Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Transmitted by the + station at 12Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 12 } + + wlanStaTxPktsAt18Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Transmitted by the + station at 18Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 13 } + + wlanStaTxBytesAt18Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Transmitted by the + station at 18Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 14 } + + wlanStaTxPktsAt24Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Transmitted by the + station at 24Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 15 } + + wlanStaTxBytesAt24Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Transmitted by the + station at 24Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 16 } + + wlanStaTxPktsAt36Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Transmitted by the + station at 36Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 17 } + + wlanStaTxBytesAt36Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Transmitted by the + station at 36Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 18 } + + wlanStaTxPktsAt48Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Transmitted by the + station at 48Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 19 } + + wlanStaTxBytesAt48Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Transmitted by the + station at 48Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 20 } + + wlanStaTxPktsAt54Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Transmitted by the + station at 54Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 21 } + + wlanStaTxBytesAt54Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Transmitted by the + station at 54Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 22 } + + wlanStaRxPktsAt1Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Received by the + station at 1Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 23 } + + wlanStaRxBytesAt1Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Received by the + station at 1Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 24 } + + wlanStaRxPktsAt2Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Received by the + station at 2Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 25 } + + wlanStaRxBytesAt2Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Received by the + station at 2Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 26 } + + wlanStaRxPktsAt5Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Received by the + station at 5Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 27 } + + wlanStaRxBytesAt5Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Received by the + station at 5Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 28 } + + wlanStaRxPktsAt11Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Received by the + station at 11Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 29 } + + wlanStaRxBytesAt11Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Received by the + station at 11Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 30 } + + wlanStaRxPktsAt6Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Received by the + station at 6Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 31 } + + wlanStaRxBytesAt6Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Received by the + station at 6Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 32 } + + wlanStaRxPktsAt12Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Received by the + station at 12Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 33 } + + wlanStaRxBytesAt12Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Received by the + station at 12Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 34 } + + wlanStaRxPktsAt18Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Received by the + station at 18Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 35 } + + wlanStaRxBytesAt18Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Received by the + station at 18Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 36 } + + wlanStaRxPktsAt24Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Received by the + station at 24Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 37 } + + wlanStaRxBytesAt24Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Received by the + station at 24Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 38 } + + wlanStaRxPktsAt36Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Received by the + station at 36Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 39 } + + wlanStaRxBytesAt36Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Received by the + station at 36Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 40 } + + wlanStaRxPktsAt48Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Received by the + station at 48Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 41 } + + wlanStaRxBytesAt48Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Received by the + station at 48Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 42 } + + wlanStaRxPktsAt54Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Received by the + station at 54Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 43 } + + wlanStaRxBytesAt54Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Received by the + station at 54Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 44 } + + wlanStaTxPktsAt9Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Transmitted by the + station at 9Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 45 } + + wlanStaTxBytesAt9Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Transmitted by the + station at 9Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 46 } + + + wlanStaRxPktsAt9Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Packets Received by the + station at 9Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 47 } + + wlanStaRxBytesAt9Mbps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Octets Received by the + station at 9Mbps rate. + " + ::= { wlsxWlanStaRateStatsEntry 48 } + +-- This table breaks down the Station statistics based on the +-- Destination Address Types. + + wlsxWlanStaDATypeStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlsxWlanStaDATypeStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This table contains all the Packet and Byte Counts for a station but + but broken down in terms of Destination Address Type. + " + ::= { wlsxWlanStationStatsGroup 3} + + wlsxWlanStaDATypeStatsEntry OBJECT-TYPE + SYNTAX WlsxWlanStaDATypeStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + Destination Address based packet and byte count entry for a + station + " + INDEX {wlanStaPhyAddress} + ::= { wlsxWlanStaDATypeStatsTable 1 } + + WlsxWlanStaDATypeStatsEntry ::= + SEQUENCE { + wlanStaTxDABroadcastPkts Counter32 , + wlanStaTxDABroadcastBytes Counter32 , + wlanStaTxDAMulticastPkts Counter32 , + wlanStaTxDAMulticastBytes Counter32 , + wlanStaTxDAUnicastPkts Counter32 , + wlanStaTxDAUnicastBytes Counter32 + + } + + wlanStaTxDABroadcastPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Broadcast packets + transmitted by this Station. + " + ::= { wlsxWlanStaDATypeStatsEntry 1 } + + wlanStaTxDABroadcastBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Broadcast Bytes + transmitted by this Station. + " + ::= { wlsxWlanStaDATypeStatsEntry 2 } + + wlanStaTxDAMulticastPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Multicast packets + transmitted by this station. + " + ::= { wlsxWlanStaDATypeStatsEntry 3 } + + wlanStaTxDAMulticastBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of Multicast Bytes + transmitted by this station. + " + ::= { wlsxWlanStaDATypeStatsEntry 4 } + + wlanStaTxDAUnicastPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total of Unicast packets + transmitted by this station. + " + ::= { wlsxWlanStaDATypeStatsEntry 5 } + + wlanStaTxDAUnicastBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the total of Unicast Bytes + transmitted by this station. + " + ::= { wlsxWlanStaDATypeStatsEntry 6 } + +-- This table breaks down the Station statistics based on the +-- the Type of the Packet. + + wlsxWlanStaFrameTypeStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlsxWlanStaFrameTypeStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This table contains all the Packet and Byte Counts for stations + but broken down into different Frame Types. + " + ::= { wlsxWlanStationStatsGroup 4} + + wlsxWlanStaFrameTypeStatsEntry OBJECT-TYPE + SYNTAX WlsxWlanStaFrameTypeStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Frame Type based packet and byte count entry for a station" + INDEX {wlanStaPhyAddress} + ::= { wlsxWlanStaFrameTypeStatsTable 1 } + + WlsxWlanStaFrameTypeStatsEntry ::= + SEQUENCE { + wlanStaTxMgmtPkts Counter32 , + wlanStaTxMgmtBytes Counter32 , + wlanStaTxCtrlPkts Counter32 , + wlanStaTxCtrlBytes Counter32 , + wlanStaTxDataPkts Counter32 , + wlanStaTxDataBytes Counter32 , + wlanStaRxMgmtPkts Counter32 , + wlanStaRxMgmtBytes Counter32 , + wlanStaRxCtrlPkts Counter32 , + wlanStaRxCtrlBytes Counter32 , + wlanStaRxDataPkts Counter32 , + wlanStaRxDataBytes Counter32 + + } + + wlanStaTxMgmtPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the Transmitted Management packets + from a station. + " + ::= { wlsxWlanStaFrameTypeStatsEntry 1 } + + wlanStaTxMgmtBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the Transmitted Management Bytes + from a station + " + ::= { wlsxWlanStaFrameTypeStatsEntry 2 } + + wlanStaTxCtrlPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the Transmitted Control packets + from a station + " + ::= { wlsxWlanStaFrameTypeStatsEntry 3 } + + wlanStaTxCtrlBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the Transmitted Control Bytes + from a station + " + ::= { wlsxWlanStaFrameTypeStatsEntry 4 } + + wlanStaTxDataPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the Transmitted Data packets + from a station + " + ::= { wlsxWlanStaFrameTypeStatsEntry 5 } + + wlanStaTxDataBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the Transmitted Data Bytes + observed on this channel. + " + ::= { wlsxWlanStaFrameTypeStatsEntry 6 } + + wlanStaRxMgmtPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of received Management packets + at a station. + " + ::= { wlsxWlanStaFrameTypeStatsEntry 7 } + + wlanStaRxMgmtBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of received Management Bytes + at a station. + " + ::= { wlsxWlanStaFrameTypeStatsEntry 8 } + + wlanStaRxCtrlPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of received Control packets + at a station. + " + ::= { wlsxWlanStaFrameTypeStatsEntry 9 } + + wlanStaRxCtrlBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of received Control Bytes + at a station. + " + ::= { wlsxWlanStaFrameTypeStatsEntry 10 } + + wlanStaRxDataPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of received Data packets + at a station. + " + ::= { wlsxWlanStaFrameTypeStatsEntry 11 } + + wlanStaRxDataBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of received Data Bytes + at a station. + " + ::= { wlsxWlanStaFrameTypeStatsEntry 12 } + + +-- This table breaks down the Station statistics received or transmitted by a +-- station into packet size buckets. + + wlsxWlanStaPktSizeStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlsxWlanStaPktSizeStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This table contains all the Packet and Byte Counts for stations + but broken down into different Packet Sizes. + " + ::= { wlsxWlanStationStatsGroup 5} + + wlsxWlanStaPktSizeStatsEntry OBJECT-TYPE + SYNTAX WlsxWlanStaPktSizeStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Packet Size based packet count entry for a station" + INDEX {wlanStaPhyAddress} + ::= { wlsxWlanStaPktSizeStatsTable 1 } + + WlsxWlanStaPktSizeStatsEntry ::= + SEQUENCE { + wlanStaTxPkts63Bytes Counter32 , + wlanStaTxPkts64To127 Counter32 , + wlanStaTxPkts128To255 Counter32 , + wlanStaTxPkts256To511 Counter32 , + wlanStaTxPkts512To1023 Counter32 , + wlanStaTxPkts1024To1518 Counter32 , + wlanStaRxPkts63Bytes Counter32 , + wlanStaRxPkts64To127 Counter32 , + wlanStaRxPkts128To255 Counter32 , + wlanStaRxPkts256To511 Counter32 , + wlanStaRxPkts512To1023 Counter32 , + wlanStaRxPkts1024To1518 Counter32 + + } + + wlanStaTxPkts63Bytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of packets transmitted by the + station that were less than 64 bytes long. + " + ::= { wlsxWlanStaPktSizeStatsEntry 1 } + + wlanStaTxPkts64To127 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of packets transmitted by the + station that were between 64 and 127 bytes long. + " + ::= { wlsxWlanStaPktSizeStatsEntry 2 } + + wlanStaTxPkts128To255 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of packets transmitted by the + station that were between 128 and 255 bytes long. + " + ::= { wlsxWlanStaPktSizeStatsEntry 3 } + + wlanStaTxPkts256To511 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of packets transmitted by the + station that were between 256 and 511 bytes long. + " + ::= { wlsxWlanStaPktSizeStatsEntry 4 } + + wlanStaTxPkts512To1023 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of packets transmitted by the + station that were between 512 and 1023 bytes long. + " + ::= { wlsxWlanStaPktSizeStatsEntry 5 } + + wlanStaTxPkts1024To1518 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of packets transmitted by the + station that were between 1024 and 1518 bytes long. + " + ::= { wlsxWlanStaPktSizeStatsEntry 6 } + + wlanStaRxPkts63Bytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of packets Received by the + station that were less than 64 bytes long. + " + ::= { wlsxWlanStaPktSizeStatsEntry 7 } + + wlanStaRxPkts64To127 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of packets Received by the + station that were between 64 and 127 bytes long. + " + ::= { wlsxWlanStaPktSizeStatsEntry 8 } + + wlanStaRxPkts128To255 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of packets Received by the + station that were between 128 and 255 bytes long. + " + ::= { wlsxWlanStaPktSizeStatsEntry 9 } + + wlanStaRxPkts256To511 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of packets Received by the + station that were between 256 and 511 bytes long. + " + ::= { wlsxWlanStaPktSizeStatsEntry 10 } + + wlanStaRxPkts512To1023 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of packets Received by the + station that were between 512 and 1023 bytes long. + " + ::= { wlsxWlanStaPktSizeStatsEntry 11 } + + wlanStaRxPkts1024To1518 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the number of packets Received by the + station that were between 1024 and 1518 bytes long. + " + ::= { wlsxWlanStaPktSizeStatsEntry 12 } + +-- wlsxWlanSwitchStatsGroup contains all statistics related to +-- the whole network controlled by the controller. + +-- wlsxWlanESSIDStatsTable contains all statistics collected +-- for an ESSID on the switch + + wlsxWlanESSIDStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanESSIDStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This Table lists statistics of the ESSID + controlled by this controller. + " + ::= { wlsxWlanSwitchStatsGroup 1} + + wlsxWlanESSIDStatsEntry OBJECT-TYPE + SYNTAX WlanESSIDStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "ESSID Stats Entry" + INDEX {wlanESSID} + ::= { wlsxWlanESSIDStatsTable 1 } + + WlanESSIDStatsEntry ::= + SEQUENCE { + wlanESSIDRxPkts Counter32, + wlanESSIDRxDroppedPkts Counter32, + wlanESSIDRxRetryPkts Counter32, + wlanESSIDTxPkts Counter32, + wlanESSIDTxDroppedPkts Counter32, + wlanESSIDTxRetryPkts Counter32, + wlanESSIDTxErrorPkts Counter32, + wlanESSIDRxRate Gauge32, + wlanESSIDTxRate Gauge32, + wlanESSIDWiredRxPkts Counter32, + wlanESSIDWiredRxBytes Counter32, + wlanESSIDWiredTxBytes Counter32 + } + + wlanESSIDRxPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The total number of packets on the ESSID uplink channel + of wireless side. + " + ::= { wlsxWlanESSIDStatsEntry 1 } + + wlanESSIDRxDroppedPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The total number of dropped packets on the ESSID uplink + channel of wireless side. + " + ::= { wlsxWlanESSIDStatsEntry 2 } + + wlanESSIDRxRetryPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The total number of re-transmission packets on the ESSID + uplink channel of wireless side. + " + ::= { wlsxWlanESSIDStatsEntry 3 } + + wlanESSIDTxPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The total number of packets on the ESSID downlink channel + of wireless side. + " + ::= { wlsxWlanESSIDStatsEntry 4 } + + wlanESSIDTxDroppedPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The total number of dropped packets on the ESSID downlink + channel of wireless side. + " + ::= { wlsxWlanESSIDStatsEntry 5 } + + wlanESSIDTxRetryPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The total number of re-transmission packets on the ESSID + downlink channel of wireless side. + " + ::= { wlsxWlanESSIDStatsEntry 6 } + + wlanESSIDTxErrorPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The total number of error packets on the ESSID downlink + channel of wireless side. + " + ::= { wlsxWlanESSIDStatsEntry 7 } + + wlanESSIDRxRate OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The data rate received from the ESSID in sampling interval, + unit is kbyte/s. + " + ::= { wlsxWlanESSIDStatsEntry 8 } + + wlanESSIDTxRate OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The data rate transmitted from the ESSID in sampling interval, + unit is kbyte/s. + " + ::= { wlsxWlanESSIDStatsEntry 9 } + + wlanESSIDWiredRxPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The total number of packets on the ESSID uplink + channel of wired side. + " + ::= { wlsxWlanESSIDStatsEntry 10 } + + wlanESSIDWiredRxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The total number of bytes on the ESSID uplink + channel of wireless side. + " + ::= { wlsxWlanESSIDStatsEntry 11 } + + wlanESSIDWiredTxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The total number of bytes on the ESSID downlink + channel of wireless side. + " + ::= { wlsxWlanESSIDStatsEntry 12 } + +-- wlsxWlanEthStatsTable will contain all the statistics collected +-- for all ethernet ports + + wlsxWlanEthStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanEthStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This Table lists statistics of all ethernet ports + of this controller. + " + ::= { wlsxWlanSwitchStatsGroup 2} + + wlsxWlanEthStatsEntry OBJECT-TYPE + SYNTAX WlanEthStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Ethernet Port Stats Entry" + INDEX {ifIndex} + ::= { wlsxWlanEthStatsTable 1 } + + WlanEthStatsEntry ::= + SEQUENCE { + wlanEthRxRate Gauge32, + wlanEthTxRate Gauge32 + } + + wlanEthRxRate OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The data rate received from the ethernet port in sampling interval, + unit is kbyte/s. + " + ::= { wlsxWlanEthStatsEntry 1 } + + wlanEthTxRate OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The data rate transmitted from the ethernet port in sampling interval, + unit is kbyte/s. + " + ::= { wlsxWlanEthStatsEntry 2 } + +-- wlsxSSIDConfigGroup contains all configuration related to +-- the SSID controlled by the controller. + +-- wlsxSSIDConfigTable contains the global configuration of the SSID + + wlsxSSIDConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanSSIDConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This Table lists the configuration of the SSID. + Note: Currently, this table doesn't return any data. + " + ::= { wlsxSSIDConfigGroup 1} + + wlsxSSIDConfigEntry OBJECT-TYPE + SYNTAX WlanSSIDConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "AP Configuration Entry" + INDEX {wlanAPMacAddress, wlanAPRadioNumber, wlanESSID, wlanESSIDIndex} + ::= { wlsxSSIDConfigTable 1 } + + WlanSSIDConfigEntry ::= + SEQUENCE { + wlanESSIDIndex Integer32, + wlanSSIDConfigHideSSID TruthValue, + wlanSSIDConfigNumStaAllowed Unsigned32, + wlanSSIDConfigWmmBeDscp Unsigned32, + wlanSSIDConfigWmmBkDscp Unsigned32, + wlanSSIDConfigWmmViDscp Unsigned32, + wlanSSIDConfigWmmVoDscp Unsigned32 + } + + wlanESSIDIndex OBJECT-TYPE + SYNTAX Integer32(1..16) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This attribute indicates the index of ESSID. We support up to 16 ESSIDs. + " + ::= { wlsxSSIDConfigEntry 1 } + + wlanSSIDConfigHideSSID OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates if SSID is hidden or not. + " + ::= { wlsxSSIDConfigEntry 2 } + + wlanSSIDConfigNumStaAllowed OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the maximum number of stations that are allowed to access into the network. + " + ::= { wlsxSSIDConfigEntry 3 } + + wlanSSIDConfigWmmBeDscp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the QoS priority of best-effort service. + " + ::= { wlsxSSIDConfigEntry 4 } + + wlanSSIDConfigWmmBkDscp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the QoS priority of background service. + " + ::= { wlsxSSIDConfigEntry 5 } + + wlanSSIDConfigWmmViDscp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the QoS priority of video service. + " + ::= { wlsxSSIDConfigEntry 6 } + + wlanSSIDConfigWmmVoDscp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + This attribute indicates the QoS priority of voice service. + " + ::= { wlsxSSIDConfigEntry 7 } + +-- wlsxAPConfigGroup contains all configuration related to +-- the APs controlled by the controller. + +-- wlsxAPConfigTable contains the global configuration of the AP + + wlsxAPConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF WlanAPConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " + This Table lists the configuration of the Access Point. + " + ::= { wlsxAPConfigGroup 1} + + wlsxAPConfigEntry OBJECT-TYPE + SYNTAX WlanAPConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "AP Configuration Entry" + INDEX {wlanAPMacAddress} + ::= { wlsxAPConfigTable 1 } + + WlanAPConfigEntry ::= + SEQUENCE { + wlanAPConfigNetmask IpAddress, + wlanAPConfigGateway IpAddress + } + + wlanAPConfigNetmask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The netmask of AP IP Address. + " + ::= { wlsxAPConfigEntry 1 } + + wlanAPConfigGateway OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + The gateway of the AP. + " + ::= { wlsxAPConfigEntry 2 } + + --Trap Definition + wlsxRAPActiveUplink NOTIFICATION-TYPE + OBJECTS {wlanAPActiveUplink, wlanAPMacAddress} + STATUS current + DESCRIPTION + "A trap which indicates the RAP Active Uplink" + ::= { wlsxRAPTraps 1 } +END diff --git a/MIBs/dell-wlan.my b/MIBs/dell-wlan.my new file mode 100644 index 0000000..afcd5e4 --- /dev/null +++ b/MIBs/dell-wlan.my @@ -0,0 +1,143 @@ +-- ArubaOS 6.4.3.7_53990 +DELL-WLAN-MIB DEFINITIONS ::= BEGIN + + IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, + OBJECT-IDENTITY, + enterprises, + snmpModules FROM SNMPv2-SMI + TEXTUAL-CONVENTION FROM SNMPv2-TC + MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF; + + +-- The top node + +dell OBJECT IDENTIFIER ::= { enterprises 674 } +powerConnect OBJECT IDENTIFIER ::= { dell 10895 } + +-- Dell W-650 product, this object is the SYSOID +w-650 OBJECT IDENTIFIER ::= { powerConnect 5001 } +-- Dell W-651 product, this object is the SYSOID +w-651 OBJECT IDENTIFIER ::= { powerConnect 5002 } +-- Dell W-3200 product, this object is the SYSOID +w-3200 OBJECT IDENTIFIER ::= { powerConnect 5003 } +-- Dell W-3400 product, this object is the SYSOID +w-3400 OBJECT IDENTIFIER ::= { powerConnect 5004 } +-- Dell W-3600 product, this object is the SYSOID +w-3600 OBJECT IDENTIFIER ::= { powerConnect 5005 } +-- Dell W-AP92 product, this object is the SYSOID +w-AP92 OBJECT IDENTIFIER ::= { powerConnect 5006 } +-- Dell W-AP93 product, this object is the SYSOID +w-AP93 OBJECT IDENTIFIER ::= { powerConnect 5007 } +-- Dell W-AP105 product, this object is the SYSOID +w-AP105 OBJECT IDENTIFIER ::= { powerConnect 5008 } +-- Dell W-AP124 product, this object is the SYSOID +w-AP124 OBJECT IDENTIFIER ::= { powerConnect 5009 } +-- Dell W-AP125 product, this object is the SYSOID +w-AP125 OBJECT IDENTIFIER ::= { powerConnect 5010 } +-- Dell W-RAP5 product, this object is the SYSOID +w-RAP5 OBJECT IDENTIFIER ::= { powerConnect 5011 } +-- Dell W-RAP5WN product, this object is the SYSOID +w-RAP5WN OBJECT IDENTIFIER ::= { powerConnect 5012 } +-- Dell W-RAP2 product, this object is the SYSOID +w-RAP2 OBJECT IDENTIFIER ::= { powerConnect 5013 } +-- Dell W-620 product, this object is the SYSOID +w-620 OBJECT IDENTIFIER ::= { powerConnect 5014 } + +-- Dell W-6000M3 product, this object is the SYSOID +w-6000M3 OBJECT IDENTIFIER ::= { powerConnect 5015 } + +-- Dell W-7210 product, this object is the SYSOID +w-7210 OBJECT IDENTIFIER ::= { powerConnect 5027 } +-- Dell W-7220 product, this object is the SYSOID +w-7220 OBJECT IDENTIFIER ::= { powerConnect 5028 } +-- Dell W-7240 product, this object is the SYSOID +w-7240 OBJECT IDENTIFIER ::= { powerConnect 5029 } + +-- Dell W-7005 product, this object is the SYSOID +w-7005 OBJECT IDENTIFIER ::= { powerConnect 5043 } +-- Dell W-7010 product, this object is the SYSOID +w-7010 OBJECT IDENTIFIER ::= { powerConnect 5044 } +-- Dell W-7030 product, this object is the SYSOID +w-7030 OBJECT IDENTIFIER ::= { powerConnect 5049 } + +-- Dell W-7205 product, this object is the SYSOID +w-7205 OBJECT IDENTIFIER ::= { powerConnect 5050 } +-- Dell W-7024 product, this object is the SYSOID +w-7024 OBJECT IDENTIFIER ::= { powerConnect 5051 } + +-- Dell W-AP68 product, this object is the SYSOID +w-AP68 OBJECT IDENTIFIER ::= { powerConnect 5016 } +-- Dell W-AP68P product, this object is the SYSOID +w-AP68P OBJECT IDENTIFIER ::= { powerConnect 5017 } + +-- Dell W-AP175P product, this object is the SYSOID +w-AP175P OBJECT IDENTIFIER ::= { powerConnect 5018 } +-- Dell W-AP175AC product, this object is the SYSOID +w-AP175AC OBJECT IDENTIFIER ::= { powerConnect 5019 } +-- Dell W-AP175DC product, this object is the SYSOID +w-AP175DC OBJECT IDENTIFIER ::= { powerConnect 5020 } + +-- Dell W-AP134 product, this object is the SYSOID +w-AP134 OBJECT IDENTIFIER ::= { powerConnect 5021 } +-- Dell W-AP135 product, this object is the SYSOID +w-AP135 OBJECT IDENTIFIER ::= { powerConnect 5022 } + +-- Dell W-AP93H product, this object is the SYSOID +w-AP93H OBJECT IDENTIFIER ::= { powerConnect 5023 } +-- Dell W-AP104 product, this object is the SYSOID +w-AP104 OBJECT IDENTIFIER ::= { powerConnect 5024 } + +-- Dell W-RAP3WN product, this object is the SYSOID +w-IAP3WN OBJECT IDENTIFIER ::= { powerConnect 5025 } +-- Dell W-RAP3WNP product, this object is the SYSOID +w-IAP3WNP OBJECT IDENTIFIER ::= { powerConnect 5026 } + +-- Dell W-IAP108 product, this object is the SYSOID +w-IAP108 OBJECT IDENTIFIER ::= { powerConnect 5031 } +-- Dell W-IAP109 product, this object is the SYSOID +w-IAP109 OBJECT IDENTIFIER ::= { powerConnect 5032 } + + +-- Dell W-AP224 product, this object is the SYSOID +w-AP224 OBJECT IDENTIFIER ::= { powerConnect 5033 } +-- Dell W-AP225 product, this object is the SYSOID +w-AP225 OBJECT IDENTIFIER ::= { powerConnect 5034 } + + +-- Dell W-IAP155 product, this object is the SYSOID +w-IAP155 OBJECT IDENTIFIER ::= { powerConnect 5035 } +-- Dell W-IAP155P product, this object is the SYSOID +w-IAP155P OBJECT IDENTIFIER ::= { powerConnect 5036 } +-- Dell W-AP114 product, this object is the SYSOID +w-AP114 OBJECT IDENTIFIER ::= { powerConnect 5037 } +-- Dell W-AP115 product, this object is the SYSOID +w-AP115 OBJECT IDENTIFIER ::= { powerConnect 5038 } + +-- Dell W-AP274 product, this object is the SYSOID +w-AP274 OBJECT IDENTIFIER ::= { powerConnect 5039 } +-- Dell W-AP275 product, this object is the SYSOID +w-AP275 OBJECT IDENTIFIER ::= { powerConnect 5040 } +-- Dell W-AP277 product, this object is the SYSOID +w-AP277 OBJECT IDENTIFIER ::= { powerConnect 5052 } +-- Dell W-AP228 product, this object is the SYSOID +w-AP228 OBJECT IDENTIFIER ::= { powerConnect 5054 } + +-- Dell W-AP103 product, this object is the SYSOID +w-AP103 OBJECT IDENTIFIER ::= { powerConnect 5045 } +-- Dell W-AP103H product, this object is the SYSOID +w-AP103H OBJECT IDENTIFIER ::= { powerConnect 5046 } + +-- Dell W-AP204 product, this object is the SYSOID +w-AP204 OBJECT IDENTIFIER ::= { powerConnect 5047 } +-- Dell W-AP205 product, this object is the SYSOID +w-AP205 OBJECT IDENTIFIER ::= { powerConnect 5048 } +-- Dell W-AP205H product, this object is the SYSOID +w-AP205H OBJECT IDENTIFIER ::= { powerConnect 5055 } + +-- Dell W-AP214 product, this object is the SYSOID +w-AP214 OBJECT IDENTIFIER ::= { powerConnect 5041 } +-- Dell W-AP215 product, this object is the SYSOID +w-AP215 OBJECT IDENTIFIER ::= { powerConnect 5042 } + +END diff --git a/MIBs/netbotz300.txt b/MIBs/netbotz300.txt new file mode 100644 index 0000000..bd9af6a --- /dev/null +++ b/MIBs/netbotz300.txt @@ -0,0 +1,8803 @@ +-- +-- NETBOTZ-MIB module definition +-- + +NETBOTZ300-MIB DEFINITIONS ::= BEGIN + IMPORTS + MODULE-IDENTITY, OBJECT-TYPE,NOTIFICATION-TYPE, enterprises, Counter32,Integer32 FROM SNMPv2-SMI + TEXTUAL-CONVENTION, DisplayString, DateAndTime FROM SNMPv2-TC; + +netBotz-APC MODULE-IDENTITY + LAST-UPDATED "200801210000Z" + ORGANIZATION "Scheider Electric / APC" + CONTACT-INFO + "Postal: Scheider Electric / APC + 132 Fairgrounds Road + West Kingston, RI 02892 + US + + Tel: +1 401 789 5735 + + E-mail: " + DESCRIPTION + "NetBotz-APC BotzWare MIB" + REVISION "200805010000Z" -- 01 May 2008" + DESCRIPTION "for Netbotz Version 3.0" + ::= { enterprises 5528 100 1 } + +netBotz-APC OBJECT IDENTIFIER ::= { enterprises 5528 } +netBotz OBJECT IDENTIFIER ::= { netBotz-APC 100 } +netBotzTraps OBJECT IDENTIFIER ::= { netBotz 10 } +netBotzTrapParms OBJECT IDENTIFIER ::= { netBotz 11 } +netBotzProducts OBJECT IDENTIFIER ::= { netBotz 20 } + +netBotzGenericTraps OBJECT IDENTIFIER ::= { netBotzTraps 1 } +netBotzSensorTraps OBJECT IDENTIFIER ::= { netBotzTraps 2 } +netBotzPodTraps OBJECT IDENTIFIER ::= { netBotzTraps 3 } +netBotzPortTraps OBJECT IDENTIFIER ::= { netBotzTraps 4 } + +netBotzTempSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 1 } +netBotzHumiditySensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 2 } +netBotzDewPointSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 3 } +netBotzAirFlowSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 4 } +netBotzAudioSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 5 } +netBotzAmpDetectSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 6 } +netBotzDryContactSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 7 } +netBotzCameraMotionSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 8 } +netBotzDoorSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 9 } +netBotzMicPlugSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 10 } +netBotzSpeakerPlugSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 11 } +netBotzTVSignalSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 12 } +netBotzGPSPositionSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 13 } +netBotzGPSMovementSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 14 } +netBotzGPSStatusSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 15 } +netBotzWirelessStatusSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 22 } +netBotzPacketDropSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 23 } +netBotzSNMPCrawlerSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 24 } +netBotzPlugModuleStatusSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 25 } +netBotzOutputControlSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 26 } +netBotzMultiRAESensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 27 } +netBotzMultiRAESensorStatusTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 28 } +netBotzMultiRAEDeviceStatusTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 29 } +netBotzLinkStatusSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 30 } +netBotzLoopVoltageSensorTraps OBJECT IDENTIFIER ::= { netBotzSensorTraps 31 } + +netBotzBasePodTraps OBJECT IDENTIFIER ::= { netBotzPodTraps 1 } +netBotzSensorPodTraps OBJECT IDENTIFIER ::= { netBotzPodTraps 2 } +netBotzCameraPodTraps OBJECT IDENTIFIER ::= { netBotzPodTraps 3 } +netBotzCCTVPodTraps OBJECT IDENTIFIER ::= { netBotzPodTraps 4 } +netBotz4to20mAPodTraps OBJECT IDENTIFIER ::= { netBotzPodTraps 5 } + +netBotzBotz OBJECT IDENTIFIER ::= { netBotzProducts 10 } + +netBotzWallBotz500 OBJECT IDENTIFIER ::= { netBotzBotz 2000 } +netBotz420Wall OBJECT IDENTIFIER ::= { netBotzBotz 2001 } +raeSystemsAreaConnect500 OBJECT IDENTIFIER ::= { netBotzBotz 2002 } +netBotz420Rack OBJECT IDENTIFIER ::= { netBotzBotz 2003 } +netBotz320Wall OBJECT IDENTIFIER ::= { netBotzBotz 2004 } +netBotz320Rack OBJECT IDENTIFIER ::= { netBotzBotz 2005 } +netBotz420ERack OBJECT IDENTIFIER ::= { netBotzBotz 2006 } +netBotz320ERack OBJECT IDENTIFIER ::= { netBotzBotz 2007 } +netBotz220Camera OBJECT IDENTIFIER ::= { netBotzBotz 2008 } +apprion500 OBJECT IDENTIFIER ::= { netBotzBotz 2009 } +avocent500 OBJECT IDENTIFIER ::= { netBotzBotz 2010 } +netBotz320EWall OBJECT IDENTIFIER ::= { netBotzBotz 2011 } +netBotz420EWall OBJECT IDENTIFIER ::= { netBotzBotz 2012 } +netBotz550Rack OBJECT IDENTIFIER ::= { netBotzBotz 2013 } +netBotz450Rack OBJECT IDENTIFIER ::= { netBotzBotz 2014 } +netBotz455Wall OBJECT IDENTIFIER ::= { netBotzBotz 2015 } +netBotz355Wall OBJECT IDENTIFIER ::= { netBotzBotz 2016 } + +-- MODULE-COMPLIANCE, OBJECT-GROUP, +-- NOTIFICATION-GROUP FROM SNMPv2-CONF; + + +OperStatus ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The operational status of the device entity." + SYNTAX INTEGER { disconnected(0), error(1), normal(2) } + +ErrorStatus ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The error status of the device entity. If there are no error conditions + reported for the entity, the status is normal. Otherwise, the status is + reported as the severity value of the highest severity error condition + that is not resolved for the entity." + SYNTAX INTEGER { normal(0), info(1), warning(2), error(3), critical(4), failure(5) } + +BoolValue ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "A boolean value." + SYNTAX INTEGER { no(0), yes(1), null(2) } + +--BoolValue ::= TEXTUAL-CONVENTION +-- STATUS current +-- DESCRIPTION +-- "A boolean value." +-- SYNTAX INTEGER { no(0), yes(1), null(2) } + +netBotzEnclosures OBJECT IDENTIFIER ::= { netBotz 2 } +netBotzPorts OBJECT IDENTIFIER ::= { netBotz 3 } +netBotzSensors OBJECT IDENTIFIER ::= { netBotz 4 } +netBotzErrors OBJECT IDENTIFIER ::= { netBotz 5 } + +netBotzNumericSensors OBJECT IDENTIFIER ::= { netBotzSensors 1 } +netBotzStateSensors OBJECT IDENTIFIER ::= { netBotzSensors 2 } + +-- +-- Top-level error status - worst active alert severity +-- +netBotzErrorStatus OBJECT-TYPE + SYNTAX ErrorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The error status of the appliance. If there are no error conditions + reported for the appliance, the status is normal. Otherwise, the status is + reported as the severity value of the highest severity error condition + that is not resolved for the appliance." + ::= { netBotz 100 } + +-- +-- Enclosures +-- + +enclosureTable OBJECT-TYPE + SYNTAX SEQUENCE OF EnclosureEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of enclosures (base enclosure and pods)." + ::= { netBotzEnclosures 1 } + +enclosureEntry OBJECT-TYPE + SYNTAX EnclosureEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Enclosure entry." + INDEX { enclosureIndex } + ::= { enclosureTable 1 } + +EnclosureEntry ::= SEQUENCE { + enclosureId DisplayString, + enclosureStatus OperStatus, + enclosureErrorStatus ErrorStatus, + enclosureLabel DisplayString, + enclosureParentEncId DisplayString, + enclosureDockedToEncId DisplayString, + enclosureIndex Counter32 +} + +enclosureId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the physical enclosure." + ::= { enclosureEntry 1 } + +enclosureStatus OBJECT-TYPE + SYNTAX OperStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational status of the enclosure." + ::= { enclosureEntry 2 } + +enclosureErrorStatus OBJECT-TYPE + SYNTAX ErrorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The error status of the enclosure. If there are no error conditions + reported for the enclosure, the status is normal. Otherwise, the status is + reported as the severity value of the highest severity error condition + that is not resolved for the enclosure." + ::= { enclosureEntry 3 } + +enclosureLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique label assigned to the enclosure (or pod)." + ::= { enclosureEntry 4 } + +enclosureParentEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the parent enclosure this enclosure is attached to." + ::= { enclosureEntry 5 } + +enclosureDockedToEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the enclosure this enclosure is hard-docked with, + i.e. as when sensor and camera pods are docked with the base + system unit." + ::= { enclosureEntry 6 } + +enclosureIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the physical enclosure." + ::= { enclosureEntry 7 } + +-- +-- Ports +-- + +dinPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF DINPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of DIN port entries." + ::= { netBotzPorts 1 } + +dinPortEntry OBJECT-TYPE + SYNTAX DINPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "DIN port entry." + INDEX { dinPortIndex } + ::= { dinPortTable 1 } + +DINPortEntry ::= SEQUENCE { + dinPortId DisplayString, + dinPortStatus OperStatus, + dinPortLabel DisplayString, + dinPortEncId DisplayString, + dinPortSensorIdSuffix DisplayString, + dinPortSupportsAverage BoolValue, + dinPortSupportsRMS BoolValue, + dinPortSupportsDryContact BoolValue, + dinPortIndex Counter32 +} + +dinPortId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique id of the port." + ::= { dinPortEntry 1 } + +dinPortStatus OBJECT-TYPE + SYNTAX OperStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational status of the port." + ::= { dinPortEntry 2 } + +dinPortLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique label assigned to the port." + ::= { dinPortEntry 3 } + +dinPortEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the physical enclosure containing the port." + ::= { dinPortEntry 4 } + +dinPortSensorIdSuffix OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The ID suffix added to a sensor plugged into the port. + The ID suffix is combined with the sensor class ID when + generating a local unique id for the DIN sensor." + ::= { dinPortEntry 5 } + +dinPortSupportsAverage OBJECT-TYPE + SYNTAX BoolValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Whether the port supports returning the average voltage + reading of the sensor. This is used to determine which + classes of sensors are supported by the port." + ::= { dinPortEntry 6 } + +dinPortSupportsRMS OBJECT-TYPE + SYNTAX BoolValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Whether the port supports returning the AC RMS voltage + reading of the sensor. This is used to determine which + classes of sensors are supported by the port." + ::= { dinPortEntry 7 } + +dinPortSupportsDryContact OBJECT-TYPE + SYNTAX BoolValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Whether the port supports generating the 'open' and + 'closed' state of a dry contact sensor. This information + is used to determine which classes of sensors are supported + by the port." + ::= { dinPortEntry 8 } + +dinPortIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the port." + ::= { dinPortEntry 9 } + +otherPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF OtherPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of other port entries." + ::= { netBotzPorts 10 } + +otherPortEntry OBJECT-TYPE + SYNTAX OtherPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Other port entry." + INDEX { otherPortIndex } + ::= { otherPortTable 1 } + +OtherPortEntry ::= SEQUENCE { + otherPortId DisplayString, + otherPortStatus OperStatus, + otherPortLabel DisplayString, + otherPortEncId DisplayString, + otherPortIndex Counter32 +} + +otherPortId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique id of the port." + ::= { otherPortEntry 1 } + +otherPortStatus OBJECT-TYPE + SYNTAX OperStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational status of the port." + ::= { otherPortEntry 2 } + +otherPortLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique label assigned to the port." + ::= { otherPortEntry 3 } + +otherPortEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the physical enclosure containing the port." + ::= { otherPortEntry 4 } + +otherPortIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the port." + ::= { otherPortEntry 5 } + +-- Numeric Sensors Group +-- This group defines sensors for which the concepts of "less than" +-- and "greater than" are meaningful. + +tempSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF TempSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of temperature sensor entries." + ::= { netBotzNumericSensors 1 } + +tempSensorEntry OBJECT-TYPE + SYNTAX TempSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A temperature sensor entry." + INDEX { tempSensorIndex } + ::= { tempSensorTable 1 } + +TempSensorEntry ::= SEQUENCE { + tempSensorId DisplayString, + tempSensorValue Integer32, + tempSensorErrorStatus ErrorStatus, + tempSensorLabel DisplayString, + tempSensorEncId DisplayString, + tempSensorPortId DisplayString, + tempSensorValueStr DisplayString, + tempSensorValueInt Integer32, + tempSensorValueIntF Integer32, + tempSensorIndex Counter32 +} + +tempSensorId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique id of the sensor." + ::= { tempSensorEntry 1 } + +tempSensorValue OBJECT-TYPE + SYNTAX Integer32 (-500..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The temperature measured by the sensor in tenths of a degree Celsius." + ::= { tempSensorEntry 2 } + +tempSensorErrorStatus OBJECT-TYPE + SYNTAX ErrorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The error status of the sensor. If there are no error conditions + reported for the sensor, the status is normal. Otherwise, the status is + reported as the severity value of the highest severity error condition + that is not resolved for the sensor." + ::= { tempSensorEntry 3 } + +tempSensorLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique label assigned to the sensor." + ::= { tempSensorEntry 4 } + +tempSensorEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the physical enclosure containing the sensor." + ::= { tempSensorEntry 5 } + +tempSensorPortId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the port the sensor is plugged into (or empty string + if it is not plugged into a port)." + ::= { tempSensorEntry 6 } + +tempSensorValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The temperature reading, in degrees celsius, shown as a string (or empty string + if it is not plugged into a port)." + ::= { tempSensorEntry 7 } + +tempSensorValueInt OBJECT-TYPE + SYNTAX Integer32 (-50..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The temperature measured by the sensor in degree Celsius." + ::= { tempSensorEntry 8 } + +tempSensorValueIntF OBJECT-TYPE + SYNTAX Integer32 (-50..212) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The temperature measured by the sensor in degree Farenheit." + ::= { tempSensorEntry 9 } + +tempSensorIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the sensor." + ::= { tempSensorEntry 10 } + +humiSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF HumiSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of humidity sensor entries." + ::= { netBotzNumericSensors 2 } + +humiSensorEntry OBJECT-TYPE + SYNTAX HumiSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A humidity sensor entry." + INDEX { humiSensorIndex } + ::= { humiSensorTable 1 } + +HumiSensorEntry ::= SEQUENCE { + humiSensorId DisplayString, + humiSensorValue Integer32, + humiSensorErrorStatus ErrorStatus, + humiSensorLabel DisplayString, + humiSensorEncId DisplayString, + humiSensorPortId DisplayString, + humiSensorValueStr DisplayString, + humiSensorValueInt Integer32, + humiSensorIndex Counter32 +} + +humiSensorId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique id of the sensor." + ::= { humiSensorEntry 1 } + +humiSensorValue OBJECT-TYPE + SYNTAX Integer32 (0..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The relative humidity measured by the sensor in tenths of a percent." + ::= { humiSensorEntry 2 } + +humiSensorErrorStatus OBJECT-TYPE + SYNTAX ErrorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The error status of the sensor. If there are no error conditions + reported for the sensor, the status is normal. Otherwise, the status is + reported as the severity value of the highest severity error condition + that is not resolved for the sensor." + ::= { humiSensorEntry 3 } + +humiSensorLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique label assigned to the sensor." + ::= { humiSensorEntry 4 } + +humiSensorEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the physical enclosure containing the sensor." + ::= { humiSensorEntry 5 } + +humiSensorPortId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the port the sensor is plugged into (or empty string + if it is not plugged into a port)." + ::= { humiSensorEntry 6 } + +humiSensorValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The humidity reading, in percent, shown as a string (or empty string + if it is not plugged into a port)." + ::= { humiSensorEntry 7 } + +humiSensorValueInt OBJECT-TYPE + SYNTAX Integer32 (0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The relative humidity measured by the sensor in percent." + ::= { humiSensorEntry 8 } + +humiSensorIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the sensor." + ::= { humiSensorEntry 9 } + +dewPointSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF DewPointSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of dew point sensor entries." + ::= { netBotzNumericSensors 3 } + +dewPointSensorEntry OBJECT-TYPE + SYNTAX DewPointSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A dew point sensor entry." + INDEX { dewPointSensorIndex } + ::= { dewPointSensorTable 1 } + +DewPointSensorEntry ::= SEQUENCE { + dewPointSensorId DisplayString, + dewPointSensorValue Integer32, + dewPointSensorErrorStatus ErrorStatus, + dewPointSensorLabel DisplayString, + dewPointSensorEncId DisplayString, + dewPointSensorPortId DisplayString, + dewPointSensorValueStr DisplayString, + dewPointSensorValueInt Integer32, + dewPointSensorIndex Counter32 +} + +dewPointSensorId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique id of the sensor." + ::= { dewPointSensorEntry 1 } + +dewPointSensorValue OBJECT-TYPE + SYNTAX Integer32 (-500..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The dew point value measured by the sensor in tenths of a degree Celsius." + ::= { dewPointSensorEntry 2 } + +dewPointSensorErrorStatus OBJECT-TYPE + SYNTAX ErrorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational status of the sensor. If there are no error conditions + reported for the sensor, the status is normal. Otherwise, the status is + reported as the severity value of the highest severity error condition + that is not resolved for the sensor." + ::= { dewPointSensorEntry 3 } + +dewPointSensorLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique label assigned to the sensor." + ::= { dewPointSensorEntry 4 } + +dewPointSensorEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the physical enclosure containing the sensor." + ::= { dewPointSensorEntry 5 } + +dewPointSensorPortId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the port the sensor is plugged into (or empty string + if it is not plugged into a port)." + ::= { dewPointSensorEntry 6 } + +dewPointSensorValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The dew point reading, in degrees celsius, shown as a string (or empty string + if it is not plugged into a port)." + ::= { dewPointSensorEntry 7 } + +dewPointSensorValueInt OBJECT-TYPE + SYNTAX Integer32 (-50..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The dew point value measured by the sensor in degrees Celsius." + ::= { dewPointSensorEntry 8 } + +dewPointSensorIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the sensor." + ::= { dewPointSensorEntry 9 } + +audioSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF AudioSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of audio sensor entries." + ::= { netBotzNumericSensors 4 } + +audioSensorEntry OBJECT-TYPE + SYNTAX AudioSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An audio sensor entry." + INDEX { audioSensorIndex } + ::= { audioSensorTable 1 } + +AudioSensorEntry ::= SEQUENCE { + audioSensorId DisplayString, + audioSensorValue Integer32, + audioSensorErrorStatus ErrorStatus, + audioSensorLabel DisplayString, + audioSensorEncId DisplayString, + audioSensorPortId DisplayString, + audioSensorValueStr DisplayString, + audioSensorValueInt Integer32, + audioSensorIndex Counter32 +} + +audioSensorId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique id of the sensor." + ::= { audioSensorEntry 1 } + +audioSensorValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The (unitless) audio level measured by the sensor." + ::= { audioSensorEntry 2 } + +audioSensorErrorStatus OBJECT-TYPE + SYNTAX ErrorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The error status of the sensor. If there are no error conditions + reported for the sensor, the status is normal. Otherwise, the status is + reported as the severity value of the highest severity error condition + that is not resolved for the sensor." + ::= { audioSensorEntry 3 } + +audioSensorLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique label assigned to the sensor." + ::= { audioSensorEntry 4 } + +audioSensorEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the physical enclosure containing the sensor." + ::= { audioSensorEntry 5 } + +audioSensorPortId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the port the sensor is plugged into (or empty string + if it is not plugged into a port)." + ::= { audioSensorEntry 6 } + +audioSensorValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The audio reading shown as a string (or empty string + if it is not plugged into a port)." + ::= { audioSensorEntry 7 } + +audioSensorValueInt OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The (unitless) audio level measured by the sensor (1/10 of audioSensorValue)." + ::= { audioSensorEntry 8 } + +audioSensorIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the sensor." + ::= { audioSensorEntry 9 } + +airFlowSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFlowSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of airflow sensor entries." + ::= { netBotzNumericSensors 5 } + +airFlowSensorEntry OBJECT-TYPE + SYNTAX AirFlowSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An air flow sensor entry." + INDEX { airFlowSensorIndex } + ::= { airFlowSensorTable 1 } + +AirFlowSensorEntry ::= SEQUENCE { + airFlowSensorId DisplayString, + airFlowSensorValue Integer32, + airFlowSensorErrorStatus ErrorStatus, + airFlowSensorLabel DisplayString, + airFlowSensorEncId DisplayString, + airFlowSensorPortId DisplayString, + airFlowSensorValueStr DisplayString, + airFlowSensorValueInt Integer32, + airFlowSensorIndex Counter32 +} + +airFlowSensorId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique id of the sensor." + ::= { airFlowSensorEntry 1 } + +airFlowSensorValue OBJECT-TYPE + SYNTAX Integer32 (0..10000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The air flow measured by the sensor in tenths of a meter per minute." + ::= { airFlowSensorEntry 2 } + +airFlowSensorErrorStatus OBJECT-TYPE + SYNTAX ErrorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The error status of the sensor. If there are no error conditions + reported for the sensor, the status is normal. Otherwise, the status is + reported as the severity value of the highest severity error condition + that is not resolved for the sensor." + ::= { airFlowSensorEntry 3 } + +airFlowSensorLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique label assigned to the sensor." + ::= { airFlowSensorEntry 4 } + +airFlowSensorEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the physical enclosure containing the sensor." + ::= { airFlowSensorEntry 5 } + +airFlowSensorPortId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the port the sensor is plugged into (or empty string + if it is not plugged into a port)." + ::= { airFlowSensorEntry 6 } + +airFlowSensorValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The airflow reading, in meters per minute, shown as a string (or empty string + if it is not plugged into a port)." + ::= { airFlowSensorEntry 7 } + +airFlowSensorValueInt OBJECT-TYPE + SYNTAX Integer32 (0..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The air flow measured by the sensor in meters per minute." + ::= { airFlowSensorEntry 8 } + +airFlowSensorIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the sensor." + ::= { airFlowSensorEntry 9 } + +ampDetectSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF AmpDetectSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of amp detect sensor entries." + ::= { netBotzNumericSensors 6 } + +ampDetectSensorEntry OBJECT-TYPE + SYNTAX AmpDetectSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An ampere sensor entry." + INDEX { ampDetectSensorIndex } + ::= { ampDetectSensorTable 1 } + +AmpDetectSensorEntry ::= SEQUENCE { + ampDetectSensorId DisplayString, + ampDetectSensorValue Integer32, + ampDetectSensorErrorStatus ErrorStatus, + ampDetectSensorLabel DisplayString, + ampDetectSensorEncId DisplayString, + ampDetectSensorPortId DisplayString, + ampDetectSensorValueStr DisplayString, + ampDetectSensorValueInt Integer32, + ampDetectSensorIndex Counter32 +} + +ampDetectSensorId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique id of the sensor." + ::= { ampDetectSensorEntry 1 } + +ampDetectSensorValue OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value measured by the sensor in tenths of an ampere." + ::= { ampDetectSensorEntry 2 } + +ampDetectSensorErrorStatus OBJECT-TYPE + SYNTAX ErrorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational status of the sensor. If there are no error conditions + reported for the sensor, the status is normal. Otherwise, the status is + reported as the severity value of the highest severity error condition + that is not resolved for the sensor." + ::= { ampDetectSensorEntry 3 } + +ampDetectSensorLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique label assigned to the sensor." + ::= { ampDetectSensorEntry 4 } + +ampDetectSensorEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the physical enclosure containing the sensor." + ::= { ampDetectSensorEntry 5 } + +ampDetectSensorPortId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the port the sensor is plugged into (or empty string + if it is not plugged into a port)." + ::= { ampDetectSensorEntry 6 } + +ampDetectSensorValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The amp detect reading, in amperes, shown as a string (or empty string + if it is not plugged into a port)." + ::= { ampDetectSensorEntry 7 } + +ampDetectSensorValueInt OBJECT-TYPE + SYNTAX Integer32 (0..6554) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value measured by the sensor in amperes." + ::= { ampDetectSensorEntry 8 } + +ampDetectSensorIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the sensor." + ::= { ampDetectSensorEntry 9 } + +otherNumericSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF OtherNumericSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of other numeric sensor entries." + ::= { netBotzNumericSensors 10 } + +otherNumericSensorEntry OBJECT-TYPE + SYNTAX OtherNumericSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Other numeric sensor entry." + INDEX { otherNumericSensorIndex } + ::= { otherNumericSensorTable 1 } + +OtherNumericSensorEntry ::= SEQUENCE { + otherNumericSensorId DisplayString, + otherNumericSensorValue Integer32, + otherNumericSensorErrorStatus ErrorStatus, + otherNumericSensorLabel DisplayString, + otherNumericSensorEncId DisplayString, + otherNumericSensorPortId DisplayString, + otherNumericSensorValueStr DisplayString, + otherNumericSensorValueInt Integer32, + otherNumericSensorUnits DisplayString, + otherNumericSensorValueIntX1000 Integer32, + otherNumericSensorValueIntX1000000 Integer32, + otherNumericSensorIndex Counter32 +} + +otherNumericSensorId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique id of the sensor." + ::= { otherNumericSensorEntry 1 } + +otherNumericSensorValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value measured by the sensor in tenths of the unit of measure." + ::= { otherNumericSensorEntry 2 } + +otherNumericSensorErrorStatus OBJECT-TYPE + SYNTAX ErrorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational status of the sensor. If there are no error conditions + reported for the sensor, the status is normal. Otherwise, the status is + reported as the severity value of the highest severity error condition + that is not resolved for the sensor." + ::= { otherNumericSensorEntry 3 } + +otherNumericSensorLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique label assigned to the sensor." + ::= { otherNumericSensorEntry 4 } + +otherNumericSensorEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the physical enclosure containing the sensor." + ::= { otherNumericSensorEntry 5 } + +otherNumericSensorPortId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the port the sensor is plugged into (or empty string + if it is not plugged into a port)." + ::= { otherNumericSensorEntry 6 } + +otherNumericSensorValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading shown as a string (or empty string + if it is not plugged into a port)." + ::= { otherNumericSensorEntry 7 } + +otherNumericSensorValueInt OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value measured by the sensor in the unit of measure (1/10 of otherNumericSensorValue)" + ::= { otherNumericSensorEntry 8 } + +otherNumericSensorUnits OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit of measure for the sensor value." + ::= { otherNumericSensorEntry 9 } + +otherNumericSensorValueIntX1000 OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value measured by the sensor in thousandths of the unit of measure (100 times otherNumericSensorValue)" + ::= { otherNumericSensorEntry 10 } + +otherNumericSensorValueIntX1000000 OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value measured by the sensor in millionths of the unit of measure (100000 times otherNumericSensorValue)" + ::= { otherNumericSensorEntry 11 } + +otherNumericSensorIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the sensor." + ::= { otherNumericSensorEntry 12 } + +-- State Sensors Group +-- This group defines sensors having an integer value which is +-- a defined state id or index. + +dryContactSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF DryContactSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of dry contact sensor entries." + ::= { netBotzStateSensors 1 } + +dryContactSensorEntry OBJECT-TYPE + SYNTAX DryContactSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Dry contact sensor entry." + INDEX { dryContactSensorIndex } + ::= { dryContactSensorTable 1 } + +DryContactSensorEntry ::= SEQUENCE { + dryContactSensorId DisplayString, + dryContactSensorValue INTEGER, + dryContactSensorErrorStatus ErrorStatus, + dryContactSensorLabel DisplayString, + dryContactSensorEncId DisplayString, + dryContactSensorPortId DisplayString, + dryContactSensorValueStr DisplayString, + dryContactSensorIndex Counter32 +} + +dryContactSensorId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique id of the sensor." + ::= { dryContactSensorEntry 1 } + +dryContactSensorValue OBJECT-TYPE + SYNTAX INTEGER { null(-1), open(0), closed(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Whether the dry sensor contact is open or closed." + ::= { dryContactSensorEntry 2 } + +dryContactSensorErrorStatus OBJECT-TYPE + SYNTAX ErrorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational status of the sensor. If there are no error conditions + reported for the sensor, the status is normal. Otherwise, the status is + reported as the severity value of the highest severity error condition + that is not resolved for the sensor." + ::= { dryContactSensorEntry 3 } + +dryContactSensorLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique label assigned to the sensor." + ::= { dryContactSensorEntry 4 } + +dryContactSensorEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the physical enclosure containing the sensor." + ::= { dryContactSensorEntry 5 } + +dryContactSensorPortId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the port the sensor is plugged into (or empty string + if it is not plugged into a port)." + ::= { dryContactSensorEntry 6 } + +dryContactSensorValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The enum value label for the state reported by the sensor." + ::= { dryContactSensorEntry 7 } + +dryContactSensorIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the sensor." + ::= { dryContactSensorEntry 8 } + +doorSwitchSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF DoorSwitchSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of door switch sensor entries." + ::= { netBotzStateSensors 2 } + +doorSwitchSensorEntry OBJECT-TYPE + SYNTAX DoorSwitchSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Door switch sensor entry." + INDEX { doorSwitchSensorIndex } + ::= { doorSwitchSensorTable 1 } + +DoorSwitchSensorEntry ::= SEQUENCE { + doorSwitchSensorId DisplayString, + doorSwitchSensorValue INTEGER, + doorSwitchSensorErrorStatus ErrorStatus, + doorSwitchSensorLabel DisplayString, + doorSwitchSensorEncId DisplayString, + doorSwitchSensorPortId DisplayString, + doorSwitchSensorValueStr DisplayString, + doorSwitchSensorIndex Counter32 +} + +doorSwitchSensorId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique id of the sensor." + ::= { doorSwitchSensorEntry 1 } + +doorSwitchSensorValue OBJECT-TYPE + SYNTAX INTEGER { null(-1), open(0), closed(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Whether the door is open or closed." + ::= { doorSwitchSensorEntry 2 } + +doorSwitchSensorErrorStatus OBJECT-TYPE + SYNTAX ErrorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational status of the sensor. If there are no error conditions + reported for the sensor, the status is normal. Otherwise, the status is + reported as the severity value of the highest severity error condition + that is not resolved for the sensor." + ::= { doorSwitchSensorEntry 3 } + +doorSwitchSensorLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique label assigned to the sensor." + ::= { doorSwitchSensorEntry 4 } + +doorSwitchSensorEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the physical enclosure containing the sensor." + ::= { doorSwitchSensorEntry 5 } + +doorSwitchSensorPortId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the port the sensor is plugged into (or empty string + if it is not plugged into a port)." + ::= { doorSwitchSensorEntry 6 } + +doorSwitchSensorValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The enum value label for the state reported by the sensor." + ::= { doorSwitchSensorEntry 7 } + +doorSwitchSensorIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the sensor." + ::= { doorSwitchSensorEntry 8 } + +cameraMotionSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF CameraMotionSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of camera motion sensor entries." + ::= { netBotzStateSensors 3 } + +cameraMotionSensorEntry OBJECT-TYPE + SYNTAX CameraMotionSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Camera motion sensor entry." + INDEX { cameraMotionSensorIndex } + ::= { cameraMotionSensorTable 1 } + +CameraMotionSensorEntry ::= SEQUENCE { + cameraMotionSensorId DisplayString, + cameraMotionSensorValue INTEGER, + cameraMotionSensorErrorStatus ErrorStatus, + cameraMotionSensorLabel DisplayString, + cameraMotionSensorEncId DisplayString, + cameraMotionSensorPortId DisplayString, + cameraMotionSensorValueStr DisplayString, + cameraMotionSensorIndex Counter32 +} + +cameraMotionSensorId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique id of the sensor." + ::= { cameraMotionSensorEntry 1 } + +cameraMotionSensorValue OBJECT-TYPE + SYNTAX INTEGER { null(-1), noMotion(0), motionDetected(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Whether motion is detected by the camera sensor." + ::= { cameraMotionSensorEntry 2 } + +cameraMotionSensorErrorStatus OBJECT-TYPE + SYNTAX ErrorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational status of the sensor. If there are no error conditions + reported for the sensor, the status is normal. Otherwise, the status is + reported as the severity value of the highest severity error condition + that is not resolved for the sensor." + ::= { cameraMotionSensorEntry 3 } + +cameraMotionSensorLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique label assigned to the sensor." + ::= { cameraMotionSensorEntry 4 } + +cameraMotionSensorEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the physical enclosure containing the sensor." + ::= { cameraMotionSensorEntry 5 } + +cameraMotionSensorPortId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the port the sensor is plugged into (or empty string + if it is not plugged into a port)." + ::= { cameraMotionSensorEntry 6 } + +cameraMotionSensorValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The enum value label for the state reported by the sensor." + ::= { cameraMotionSensorEntry 7 } + +cameraMotionSensorIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the sensor." + ::= { cameraMotionSensorEntry 8 } + +otherStateSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF OtherStateSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of other state sensor entries." + ::= { netBotzStateSensors 10 } + +otherStateSensorEntry OBJECT-TYPE + SYNTAX OtherStateSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Other state sensor entry." + INDEX { otherStateSensorIndex } + ::= { otherStateSensorTable 1 } + +OtherStateSensorEntry ::= SEQUENCE { + otherStateSensorId DisplayString, + otherStateSensorValue INTEGER, + otherStateSensorErrorStatus ErrorStatus, + otherStateSensorLabel DisplayString, + otherStateSensorEncId DisplayString, + otherStateSensorPortId DisplayString, + otherStateSensorValueStr DisplayString, + otherStateSensorIndex Counter32 +} + +otherStateSensorId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique id of the sensor." + ::= { otherStateSensorEntry 1 } + +otherStateSensorValue OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "State value reported by the sensor." + ::= { otherStateSensorEntry 2 } + +otherStateSensorErrorStatus OBJECT-TYPE + SYNTAX ErrorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational status of the sensor. If there are no error conditions + reported for the sensor, the status is normal. Otherwise, the status is + reported as the severity value of the highest severity error condition + that is not resolved for the sensor." + ::= { otherStateSensorEntry 3 } + +otherStateSensorLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique label assigned to the sensor." + ::= { otherStateSensorEntry 4 } + +otherStateSensorEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the physical enclosure containing the sensor." + ::= { otherStateSensorEntry 5 } + +otherStateSensorPortId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of port the sensor is plugged into (or empty string + if it is not plugged into a port)." + ::= { otherStateSensorEntry 6 } + +otherStateSensorValueStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The enum value label for the state reported by the sensor." + ::= { otherStateSensorEntry 7 } + +otherStateSensorIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the sensor." + ::= { otherStateSensorEntry 8 } + +-- Error Conditions Group +-- + +errorCondTable OBJECT-TYPE + SYNTAX SEQUENCE OF ErrorCondEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of active and resolved error conditions." + ::= { netBotzErrors 1 } + +errorCondEntry OBJECT-TYPE + SYNTAX ErrorCondEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Error condition entry." + INDEX { errorCondIndex } + ::= { errorCondTable 1 } + +ErrorCondEntry ::= SEQUENCE { + errorCondId DisplayString, + errorCondSeverity ErrorStatus, + errorCondTypeId DisplayString, + errorCondStartTime DateAndTime, + errorCondStartTimeStr DisplayString, + errorCondResolved BoolValue, + errorCondResolvedTime DateAndTime, + errorCondResolvedTimeStr DisplayString, + errorCondEncId DisplayString, + errorCondPortId DisplayString, + errorCondSensorId DisplayString, + errorCondIndex Counter32 +} + +errorCondId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unique id of the error condition." + ::= { errorCondEntry 1 } + +errorCondSeverity OBJECT-TYPE + SYNTAX ErrorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The relative severity of the error condition." + ::= { errorCondEntry 2 } + +errorCondTypeId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The error type id reported for the error condition." + ::= { errorCondEntry 3 } + +errorCondStartTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The start time of the error condition, in msec since 1/1/1970." + ::= { errorCondEntry 4 } + +errorCondStartTimeStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The start time of the error condition, as ISO date-time formatted string (UTC)." + ::= { errorCondEntry 5 } + +errorCondResolved OBJECT-TYPE + SYNTAX BoolValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Whether the error condition was resolved." + ::= { errorCondEntry 6 } + +errorCondResolvedTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time the error condition was resolved (if it was resolved), in msec since 1/1/1970." + ::= { errorCondEntry 7 } + +errorCondResolvedTimeStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time the error condition was resolved (if it was resolved), as ISO date-time formatted string (UTC)." + ::= { errorCondEntry 8 } + +errorCondEncId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the physical enclosure associated with the error." + ::= { errorCondEntry 9 } + +errorCondPortId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the port associated with the error (or empty string + if the error is not associated with a port)." + ::= { errorCondEntry 10 } + +errorCondSensorId OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The id of the sensor associated with the error (or empty string + if the error is not associated with a sensor.)" + ::= { errorCondEntry 11 } + +errorCondIndex OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the error condition." + ::= { errorCondEntry 12 } + + +-- Alert specific definitions +-- + +netBotzTrapErrorID OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Unique ID of error condition that produced the trap" + ::= { netBotzTrapParms 1 } + +netBotzTrapErrorType OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Symbolic ID of error type" + ::= { netBotzTrapParms 2 } + + +netBotzTrapErrorTypeLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Label for error type" + ::= { netBotzTrapParms 3 } + + +netBotzTrapSensorID OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ID of sensor associated with error condition that produced the trap" + ::= { netBotzTrapParms 4 } + +netBotzTrapSensorLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Label of sensor associated with error condition that produced the trap" + ::= { netBotzTrapParms 5 } + +netBotzTrapPodID OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ID of pod associated with error condition that produced the trap" + ::= { netBotzTrapParms 6 } + +netBotzTrapPodLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Label of pod associated with error condition that produced the trap" + ::= { netBotzTrapParms 7 } + +netBotzTrapPortID OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ID of port associated with error condition that produced the trap" + ::= { netBotzTrapParms 8 } + +netBotzTrapPortLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Label of port associated with error condition that produced the trap" + ::= { netBotzTrapParms 9 } + +netBotzTrapStartTime OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Start time (in UTC seconds) for error that produced the trap" + ::= { netBotzTrapParms 10 } + +netBotzTrapNotifyTime OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Notification time (in UTC seconds) for error that produced the trap" + ::= { netBotzTrapParms 11 } + +netBotzTrapResolveTime OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Resolve time (in UTC seconds) for error that produced the trap" + ::= { netBotzTrapParms 12 } + +netBotzTrapSeverity OBJECT-TYPE + SYNTAX INTEGER { + information(0), + warning(1), + error(2), + critical(3), + failure(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Severity of error that produced the trap" + ::= { netBotzTrapParms 13 } + +netBotzTrapSensorValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "String presentation of value of sensor" + ::= { netBotzTrapParms 14 } + +netBotzTrapSensorValueInt OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Whole integer representation of value of sensor (without decimal portion)" + ::= { netBotzTrapParms 15 } + +netBotzTrapSensorValueFraction OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Fractional portion of value of sensor (multiplied by 1000000)" + ::= { netBotzTrapParms 16 } + + +netBotzTempTooHigh NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION "Temperature sensor value too high." + ::= { netBotzTempSensorTraps 0 2 } + +netBotzTempTooHighRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION "Temperature sensor value is no longer too high." + ::= { netBotzTempSensorTraps 0 102 } + +netBotzTempTooLow NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION "Temperature sensor value too low." + ::= { netBotzTempSensorTraps 0 3 } + +netBotzTempTooLowRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION "Temperature sensor value is no longer too low." + ::= { netBotzTempSensorTraps 0 103 } + +netBotzTempTooHighTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Temperature sensor value too high for too long." + ::= { netBotzTempSensorTraps 0 4 } + +netBotzTempTooHighTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Temperature sensor value is no longer too high for too long." + ::= { netBotzTempSensorTraps 0 104 } + +netBotzTempTooLowTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Temperature sensor value too low for too long." + ::= { netBotzTempSensorTraps 0 5 } + +netBotzTempTooLowForTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Temperature sensor value is no longer too low for too long." + ::= { netBotzTempSensorTraps 0 105 } + +netBotzTempUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Temperature sensor unplugged." + ::= { netBotzTempSensorTraps 0 6 } + +netBotzTempReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Temperature sensor no longer unplugged." + ::= { netBotzTempSensorTraps 0 106 } + +netBotzTempIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Temperature sensor value increasing too quickly." + ::= { netBotzTempSensorTraps 0 8 } + +netBotzTempNotIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Temperature sensor value no longer increasing too quickly." + ::= { netBotzTempSensorTraps 0 108 } + +netBotzTempDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Temperature sensor value decreasing too quickly." + ::= { netBotzTempSensorTraps 0 9 } + +netBotzTempNotDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Temperature sensor value no longer decreasing too quickly." + ::= { netBotzTempSensorTraps 0 109 } + +netBotzTempError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Temperature sensor error." + ::= { netBotzTempSensorTraps 0 1 } + +netBotzTempErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Temperature sensor error resolved." + ::= { netBotzTempSensorTraps 0 101 } + +netBotzHumidityTooHigh NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor value too high." + ::= { netBotzHumiditySensorTraps 0 2 } + +netBotzHumidityTooHighRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor value is no longer too high." + ::= { netBotzHumiditySensorTraps 0 102 } + +netBotzHumidityTooLow NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor value too low." + ::= { netBotzHumiditySensorTraps 0 3 } + +netBotzHumidityTooLowRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor value is no longer too low." + ::= { netBotzHumiditySensorTraps 0 103 } + +netBotzHumidityTooHighTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor value too high for too long." + ::= { netBotzHumiditySensorTraps 0 4 } + +netBotzHumidityTooHighTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor value is no longer too high for too long." + ::= { netBotzHumiditySensorTraps 0 104 } + +netBotzHumidityTooLowTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor value too low for too long." + ::= { netBotzHumiditySensorTraps 0 5 } + +netBotzHumidityTooLowForTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor value is no longer too low for too long." + ::= { netBotzHumiditySensorTraps 0 105 } + +netBotzHumidityUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor unplugged." + ::= { netBotzHumiditySensorTraps 0 6 } + +netBotzHumidityReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor no longer unplugged." + ::= { netBotzHumiditySensorTraps 0 106 } + +netBotzHumidityIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor value increasing too quickly." + ::= { netBotzHumiditySensorTraps 0 8 } + +netBotzHumidityNotIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor value no longer increasing too quickly." + ::= { netBotzHumiditySensorTraps 0 108 } + +netBotzHumidityDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor value decreasing too quickly." + ::= { netBotzHumiditySensorTraps 0 9 } + +netBotzHumidityNotDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor value no longer decreasing too quickly." + ::= { netBotzHumiditySensorTraps 0 109 } + +netBotzHumidityError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor error." + ::= { netBotzHumiditySensorTraps 0 1 } + +netBotzHumidityErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Humidity sensor error resolved." + ::= { netBotzHumiditySensorTraps 0 101 } + +netBotzDewPointTooHigh NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor value too high." + ::= { netBotzDewPointSensorTraps 0 2 } + +netBotzDewPointTooHighRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor value is no longer too high." + ::= { netBotzDewPointSensorTraps 0 102 } + +netBotzDewPointTooLow NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor value too low." + ::= { netBotzDewPointSensorTraps 0 3 } + +netBotzDewPointTooLowRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor value is no longer too low." + ::= { netBotzDewPointSensorTraps 0 103 } + +netBotzDewPointTooHighTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor value too high for too long." + ::= { netBotzDewPointSensorTraps 0 4 } + +netBotzDewPointTooHighTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor value is no longer too high for too long." + ::= { netBotzDewPointSensorTraps 0 104 } + +netBotzDewPointTooLowTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor value too low for too long." + ::= { netBotzDewPointSensorTraps 0 5 } + +netBotzDewPointTooLowForTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor value is no longer too low for too long." + ::= { netBotzDewPointSensorTraps 0 105 } + +netBotzDewPointUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor unplugged." + ::= { netBotzDewPointSensorTraps 0 6 } + +netBotzDewPointReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor no longer unplugged." + ::= { netBotzDewPointSensorTraps 0 106 } + +netBotzDewPointIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor value increasing too quickly." + ::= { netBotzDewPointSensorTraps 0 8 } + +netBotzDewPointNotIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor value no longer increasing too quickly." + ::= { netBotzDewPointSensorTraps 0 108 } + +netBotzDewPointDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor value decreasing too quickly." + ::= { netBotzDewPointSensorTraps 0 9 } + +netBotzDewPointNotDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor value no longer decreasing too quickly." + ::= { netBotzDewPointSensorTraps 0 109 } + +netBotzDewPointError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor error." + ::= { netBotzDewPointSensorTraps 0 1 } + +netBotzDewPointErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "DewPoint sensor error resolved." + ::= { netBotzDewPointSensorTraps 0 101 } + +netBotzAirFlowTooHigh NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor value too high." + ::= { netBotzAirFlowSensorTraps 0 2 } + +netBotzAirFlowTooHighRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor value is no longer too high." + ::= { netBotzAirFlowSensorTraps 0 102 } + +netBotzAirFlowTooLow NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor value too low." + ::= { netBotzAirFlowSensorTraps 0 3 } + +netBotzAirFlowTooLowRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor value is no longer too low." + ::= { netBotzAirFlowSensorTraps 0 103 } + +netBotzAirFlowTooHighTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor value too high for too long." + ::= { netBotzAirFlowSensorTraps 0 4 } + +netBotzAirFlowTooHighTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor value is no longer too high for too long." + ::= { netBotzAirFlowSensorTraps 0 104 } + +netBotzAirFlowTooLowTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor value too low for too long." + ::= { netBotzAirFlowSensorTraps 0 5 } + +netBotzAirFlowTooLowForTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor value is no longer too low for too long." + ::= { netBotzAirFlowSensorTraps 0 105 } + +netBotzAirFlowUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor unplugged." + ::= { netBotzAirFlowSensorTraps 0 6 } + +netBotzAirFlowReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor no longer unplugged." + ::= { netBotzAirFlowSensorTraps 0 106 } + +netBotzAirFlowIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor value increasing too quickly." + ::= { netBotzAirFlowSensorTraps 0 8 } + +netBotzAirFlowNotIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor value no longer increasing too quickly." + ::= { netBotzAirFlowSensorTraps 0 108 } + +netBotzAirFlowDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor value decreasing too quickly." + ::= { netBotzAirFlowSensorTraps 0 9 } + +netBotzAirFlowNotDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor value no longer decreasing too quickly." + ::= { netBotzAirFlowSensorTraps 0 109 } + +netBotzAirFlowError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor error." + ::= { netBotzAirFlowSensorTraps 0 1 } + +netBotzAirFlowErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "AirFlow sensor error resolved." + ::= { netBotzAirFlowSensorTraps 0 101 } + +netBotzAudioTooHigh NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor value too high." + ::= { netBotzAudioSensorTraps 0 2 } + +netBotzAudioTooHighRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor value is no longer too high." + ::= { netBotzAudioSensorTraps 0 102 } + +netBotzAudioTooLow NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor value too low." + ::= { netBotzAudioSensorTraps 0 3 } + +netBotzAudioTooLowRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor value is no longer too low." + ::= { netBotzAudioSensorTraps 0 103 } + +netBotzAudioTooHighTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor value too high for too long." + ::= { netBotzAudioSensorTraps 0 4 } + +netBotzAudioTooHighTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor value is no longer too high for too long." + ::= { netBotzAudioSensorTraps 0 104 } + +netBotzAudioTooLowTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor value too low for too long." + ::= { netBotzAudioSensorTraps 0 5 } + +netBotzAudioTooLowForTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor value is no longer too low for too long." + ::= { netBotzAudioSensorTraps 0 105 } + +netBotzAudioUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor unplugged." + ::= { netBotzAudioSensorTraps 0 6 } + +netBotzAudioReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor no longer unplugged." + ::= { netBotzAudioSensorTraps 0 106 } + +netBotzAudioIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor value increasing too quickly." + ::= { netBotzAudioSensorTraps 0 8 } + +netBotzAudioNotIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor value no longer increasing too quickly." + ::= { netBotzAudioSensorTraps 0 108 } + +netBotzAudioDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor value decreasing too quickly." + ::= { netBotzAudioSensorTraps 0 9 } + +netBotzAudioNotDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor value no longer decreasing too quickly." + ::= { netBotzAudioSensorTraps 0 109 } + +netBotzAudioError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor error." + ::= { netBotzAudioSensorTraps 0 1 } + +netBotzAudioErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Audio sensor error resolved." + ::= { netBotzAudioSensorTraps 0 101 } + +netBotzAmpDetectTooHigh NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor value too high." + ::= { netBotzAmpDetectSensorTraps 0 2 } + +netBotzAmpDetectTooHighRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor value is no longer too high." + ::= { netBotzAmpDetectSensorTraps 0 102 } + +netBotzAmpDetectTooLow NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor value too low." + ::= { netBotzAmpDetectSensorTraps 0 3 } + +netBotzAmpDetectTooLowRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor value is no longer too low." + ::= { netBotzAmpDetectSensorTraps 0 103 } + +netBotzAmpDetectTooHighTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor value too high for too long." + ::= { netBotzAmpDetectSensorTraps 0 4 } + +netBotzAmpDetectTooHighTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor value is no longer too high for too long." + ::= { netBotzAmpDetectSensorTraps 0 104 } + +netBotzAmpDetectTooLowTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor value too low for too long." + ::= { netBotzAmpDetectSensorTraps 0 5 } + +netBotzAmpDetectTooLowForTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor value is no longer too low for too long." + ::= { netBotzAmpDetectSensorTraps 0 105 } + +netBotzAmpDetectUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor unplugged." + ::= { netBotzAmpDetectSensorTraps 0 6 } + +netBotzAmpDetectReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor no longer unplugged." + ::= { netBotzAmpDetectSensorTraps 0 106 } + +netBotzAmpDetectIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor value increasing too quickly." + ::= { netBotzAmpDetectSensorTraps 0 8 } + +netBotzAmpDetectNotIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor value no longer increasing too quickly." + ::= { netBotzAmpDetectSensorTraps 0 108 } + +netBotzAmpDetectDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor value decreasing too quickly." + ::= { netBotzAmpDetectSensorTraps 0 9 } + +netBotzAmpDetectNotDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor value no longer decreasing too quickly." + ::= { netBotzAmpDetectSensorTraps 0 109 } + +netBotzAmpDetectError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor error." + ::= { netBotzAmpDetectSensorTraps 0 1 } + +netBotzAmpDetectErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Amp Detectsensor error resolved." + ::= { netBotzAmpDetectSensorTraps 0 101 } + +netBotzDryContactUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Dry Contact sensor unplugged." + ::= { netBotzDryContactSensorTraps 0 6 } + +netBotzDryContactReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Dry Contact sensor no longer unplugged." + ::= { netBotzDryContactSensorTraps 0 106 } + +netBotzDryContactError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Dry Contact sensor error." + ::= { netBotzDryContactSensorTraps 0 1 } + +netBotzDryContactErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Dry Contact sensor error resolved." + ::= { netBotzDryContactSensorTraps 0 101 } + +netBotzDryContactValueError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Dry Contact sensor value error." + ::= { netBotzDryContactSensorTraps 0 10 } + +netBotzDryContactValueErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Dry Contact sensor value error resolved." + ::= { netBotzDryContactSensorTraps 0 110 } + +netBotzCameraMotionSensorUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Camera Motion Sensor sensor unplugged." + ::= { netBotzCameraMotionSensorTraps 0 6 } + +netBotzCameraMotionSensorReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Camera Motion Sensor sensor no longer unplugged." + ::= { netBotzCameraMotionSensorTraps 0 106 } + +netBotzCameraMotionSensorError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Camera Motion Sensor sensor error." + ::= { netBotzCameraMotionSensorTraps 0 1 } + +netBotzCameraMotionSensorErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Camera Motion Sensor sensor error resolved." + ::= { netBotzCameraMotionSensorTraps 0 101 } + +netBotzCameraMotionSensorValueError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Camera Motion Sensor sensor value error." + ::= { netBotzCameraMotionSensorTraps 0 10 } + +netBotzCameraMotionSensorValueErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Camera Motion Sensor sensor value error resolved." + ::= { netBotzCameraMotionSensorTraps 0 110 } + +netBotzDoorSensorUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Door Sensor sensor unplugged." + ::= { netBotzDoorSensorTraps 0 6 } + +netBotzDoorSensorReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Door Sensor sensor no longer unplugged." + ::= { netBotzDoorSensorTraps 0 106 } + +netBotzDoorSensorError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Door Sensor sensor error." + ::= { netBotzDoorSensorTraps 0 1 } + +netBotzDoorSensorErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Door Sensor sensor error resolved." + ::= { netBotzDoorSensorTraps 0 101 } + +netBotzDoorSensorValueError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Door Sensor sensor value error." + ::= { netBotzDoorSensorTraps 0 10 } + +netBotzDoorSensorValueErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Door Sensor sensor value error resolved." + ::= { netBotzDoorSensorTraps 0 110 } + +netBotzMicPlugSensorUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MicPlug Sensor sensor unplugged." + ::= { netBotzMicPlugSensorTraps 0 6 } + +netBotzMicPlugSensorReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MicPlug Sensor sensor no longer unplugged." + ::= { netBotzMicPlugSensorTraps 0 106 } + +netBotzMicPlugSensorError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MicPlug Sensor sensor error." + ::= { netBotzMicPlugSensorTraps 0 1 } + +netBotzMicPlugSensorErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MicPlug Sensor sensor error resolved." + ::= { netBotzMicPlugSensorTraps 0 101 } + +netBotzMicPlugSensorValueError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MicPlug Sensor sensor value error." + ::= { netBotzMicPlugSensorTraps 0 10 } + +netBotzMicPlugSensorValueErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MicPlug Sensor sensor value error resolved." + ::= { netBotzMicPlugSensorTraps 0 110 } + +netBotzSpeakerPlugSensorUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SpeakerPlug Sensor sensor unplugged." + ::= { netBotzSpeakerPlugSensorTraps 0 6 } + +netBotzSpeakerPlugSensorReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SpeakerPlug Sensor sensor no longer unplugged." + ::= { netBotzSpeakerPlugSensorTraps 0 106 } + +netBotzSpeakerPlugSensorError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SpeakerPlug Sensor sensor error." + ::= { netBotzSpeakerPlugSensorTraps 0 1 } + +netBotzSpeakerPlugSensorErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SpeakerPlug Sensor sensor error resolved." + ::= { netBotzSpeakerPlugSensorTraps 0 101 } + +netBotzSpeakerPlugSensorValueError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SpeakerPlug Sensor sensor value error." + ::= { netBotzSpeakerPlugSensorTraps 0 10 } + +netBotzSpeakerPlugSensorValueErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SpeakerPlug Sensor sensor value error resolved." + ::= { netBotzSpeakerPlugSensorTraps 0 110 } + + +netBotzTVSignalSensorUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "TVSignal Sensor sensor unplugged." + ::= { netBotzTVSignalSensorTraps 0 6 } + +netBotzTVSignalSensorReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "TVSignal Sensor sensor no longer unplugged." + ::= { netBotzTVSignalSensorTraps 0 106 } + +netBotzTVSignalSensorError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "TVSignal Sensor sensor error." + ::= { netBotzTVSignalSensorTraps 0 1 } + +netBotzTVSignalSensorErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "TVSignal Sensor sensor error resolved." + ::= { netBotzTVSignalSensorTraps 0 101 } + +netBotzTVSignalSensorValueError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "TVSignal Sensor sensor value error." + ::= { netBotzTVSignalSensorTraps 0 10 } + +netBotzTVSignalSensorValueErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "TVSignal Sensor sensor value error resolved." + ::= { netBotzTVSignalSensorTraps 0 110 } + +netBotzPodUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Pod unplugged." + ::= { netBotzPodTraps 0 7 } + +netBotzPodReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Pod no longer unplugged." + ::= { netBotzPodTraps 0 107 } + +netBotzSensorPodUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Sensor Pod unplugged." + ::= { netBotzSensorPodTraps 0 7 } + +netBotzSensorPodReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Sensor Pod no longer unplugged." + ::= { netBotzSensorPodTraps 0 107 } + +netBotzCameraPodUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Camera Pod unplugged." + ::= { netBotzCameraPodTraps 0 7 } + +netBotzCameraPodReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Camera Pod no longer unplugged." + ::= { netBotzCameraPodTraps 0 107 } + +netBotzCCTVPodUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "CCTV Pod unplugged." + ::= { netBotzCCTVPodTraps 0 7 } + +netBotzCCTVPodReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "CCTV Pod no longer unplugged." + ::= { netBotzCCTVPodTraps 0 107 } + +netBotz4to20mAPodUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "4-20mA Pod unplugged." + ::= { netBotz4to20mAPodTraps 0 7 } + +netBotz4to20mAPodReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "4-20mA Pod no longer unplugged." + ::= { netBotz4to20mAPodTraps 0 107 } + +netBotzLogonError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Multiple failed logon attempts." + ::= { netBotzPodTraps 0 11 } + +netBotzLogonErrorResolved NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Failed logon attempts stopped, or logon succeeded." + ::= { netBotzPodTraps 0 111 } + +netBotzDriveNotFoundError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Configured add-on drive not found or has malfunctioned." + ::= { netBotzPodTraps 0 12 } + +netBotzDriveNotFoundErrorResolved NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Missing add-on drive has bee found." + ::= { netBotzPodTraps 0 112 } + +netBotzRmtLinkError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Configured remote link has failed." + ::= { netBotzPodTraps 0 13 } + +netBotzRmtLinkErrorResolved NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Configured remote link has returned to normal." + ::= { netBotzPodTraps 0 113 } + +netBotzGPSPositionTooHigh NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position sensor value too high." + ::= { netBotzGPSPositionSensorTraps 0 2 } + +netBotzGPSPositionTooHighRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position sensor value is no longer too high." + ::= { netBotzGPSPositionSensorTraps 0 102 } + +netBotzGPSPositionTooLow NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position sensor value too low." + ::= { netBotzGPSPositionSensorTraps 0 3 } + +netBotzGPSPositionTooLowRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position sensor value is no longer too low." + ::= { netBotzGPSPositionSensorTraps 0 103 } + +netBotzGPSPositionTooHighTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position sensor value too high for too long." + ::= { netBotzGPSPositionSensorTraps 0 4 } + +netBotzGPSPositionTooHighTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position sensor value is no longer too high for too long." + ::= { netBotzGPSPositionSensorTraps 0 104 } + +netBotzGPSPositionTooLowTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position ensor value too low for too long." + ::= { netBotzGPSPositionSensorTraps 0 5 } + +netBotzGPSPositionTooLowForTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position sensor value is no longer too low for too long." + ::= { netBotzGPSPositionSensorTraps 0 105 } + +netBotzGPSPositionUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position sensor unplugged." + ::= { netBotzGPSPositionSensorTraps 0 6 } + +netBotzGPSPositionReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position sensor no longer unplugged." + ::= { netBotzGPSPositionSensorTraps 0 106 } + +netBotzGPSPositionIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position sensor value increasing too quickly." + ::= { netBotzGPSPositionSensorTraps 0 8 } + +netBotzGPSPositionNotIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position sensor value no longer increasing too quickly." + ::= { netBotzGPSPositionSensorTraps 0 108 } + +netBotzGPSPositionDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position sensor value decreasing too quickly." + ::= { netBotzGPSPositionSensorTraps 0 9 } + +netBotzGPSPositionNotDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position sensor value no longer decreasing too quickly." + ::= { netBotzGPSPositionSensorTraps 0 109 } + +netBotzGPSPositionError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position sensor error." + ::= { netBotzGPSPositionSensorTraps 0 1 } + +netBotzGPSPositionErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Position sensor error resolved." + ::= { netBotzGPSPositionSensorTraps 0 101 } + +netBotzGPSMovementTooHigh NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement sensor value too high." + ::= { netBotzGPSMovementSensorTraps 0 2 } + +netBotzGPSMovementTooHighRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement sensor value is no longer too high." + ::= { netBotzGPSMovementSensorTraps 0 102 } + +netBotzGPSMovementTooLow NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement sensor value too low." + ::= { netBotzGPSMovementSensorTraps 0 3 } + +netBotzGPSMovementTooLowRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement sensor value is no longer too low." + ::= { netBotzGPSMovementSensorTraps 0 103 } + +netBotzGPSMovementTooHighTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement sensor value too high for too long." + ::= { netBotzGPSMovementSensorTraps 0 4 } + +netBotzGPSMovementTooHighTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement sensor value is no longer too high for too long." + ::= { netBotzGPSMovementSensorTraps 0 104 } + +netBotzGPSMovementTooLowTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement ensor value too low for too long." + ::= { netBotzGPSMovementSensorTraps 0 5 } + +netBotzGPSMovementTooLowForTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement sensor value is no longer too low for too long." + ::= { netBotzGPSMovementSensorTraps 0 105 } + +netBotzGPSMovementUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement sensor unplugged." + ::= { netBotzGPSMovementSensorTraps 0 6 } + +netBotzGPSMovementReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement sensor no longer unplugged." + ::= { netBotzGPSMovementSensorTraps 0 106 } + +netBotzGPSMovementIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement sensor value increasing too quickly." + ::= { netBotzGPSMovementSensorTraps 0 8 } + +netBotzGPSMovementNotIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement sensor value no longer increasing too quickly." + ::= { netBotzGPSMovementSensorTraps 0 108 } + +netBotzGPSMovementDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement sensor value decreasing too quickly." + ::= { netBotzGPSMovementSensorTraps 0 9 } + +netBotzGPSMovementNotDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement sensor value no longer decreasing too quickly." + ::= { netBotzGPSMovementSensorTraps 0 109 } + +netBotzGPSMovementError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement sensor error." + ::= { netBotzGPSMovementSensorTraps 0 1 } + +netBotzGPSMovementErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Movement sensor error resolved." + ::= { netBotzGPSMovementSensorTraps 0 101 } + +netBotzPacketDropTooHigh NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop sensor value too high." + ::= { netBotzPacketDropSensorTraps 0 2 } + +netBotzPacketDropTooHighRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop sensor value is no longer too high." + ::= { netBotzPacketDropSensorTraps 0 102 } + +netBotzPacketDropTooLow NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop sensor value too low." + ::= { netBotzPacketDropSensorTraps 0 3 } + +netBotzPacketDropTooLowRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop sensor value is no longer too low." + ::= { netBotzPacketDropSensorTraps 0 103 } + +netBotzPacketDropTooHighTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop sensor value too high for too long." + ::= { netBotzPacketDropSensorTraps 0 4 } + +netBotzPacketDropTooHighTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop sensor value is no longer too high for too long." + ::= { netBotzPacketDropSensorTraps 0 104 } + +netBotzPacketDropTooLowTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop ensor value too low for too long." + ::= { netBotzPacketDropSensorTraps 0 5 } + +netBotzPacketDropTooLowForTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop sensor value is no longer too low for too long." + ::= { netBotzPacketDropSensorTraps 0 105 } + +netBotzPacketDropUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop sensor unplugged." + ::= { netBotzPacketDropSensorTraps 0 6 } + +netBotzPacketDropReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop sensor no longer unplugged." + ::= { netBotzPacketDropSensorTraps 0 106 } + +netBotzPacketDropIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop sensor value increasing too quickly." + ::= { netBotzPacketDropSensorTraps 0 8 } + +netBotzPacketDropNotIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop sensor value no longer increasing too quickly." + ::= { netBotzPacketDropSensorTraps 0 108 } + +netBotzPacketDropDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop sensor value decreasing too quickly." + ::= { netBotzPacketDropSensorTraps 0 9 } + +netBotzPacketDropNotDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop sensor value no longer decreasing too quickly." + ::= { netBotzPacketDropSensorTraps 0 109 } + +netBotzPacketDropError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop sensor error." + ::= { netBotzPacketDropSensorTraps 0 1 } + +netBotzPacketDropErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Packet Drop sensor error resolved." + ::= { netBotzPacketDropSensorTraps 0 101 } + +netBotzSNMPCrawlerTooHigh NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler sensor value too high." + ::= { netBotzSNMPCrawlerSensorTraps 0 2 } + +netBotzSNMPCrawlerTooHighRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler sensor value is no longer too high." + ::= { netBotzSNMPCrawlerSensorTraps 0 102 } + +netBotzSNMPCrawlerTooLow NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler sensor value too low." + ::= { netBotzSNMPCrawlerSensorTraps 0 3 } + +netBotzSNMPCrawlerTooLowRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler sensor value is no longer too low." + ::= { netBotzSNMPCrawlerSensorTraps 0 103 } + +netBotzSNMPCrawlerTooHighTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler sensor value too high for too long." + ::= { netBotzSNMPCrawlerSensorTraps 0 4 } + +netBotzSNMPCrawlerTooHighTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler sensor value is no longer too high for too long." + ::= { netBotzSNMPCrawlerSensorTraps 0 104 } + +netBotzSNMPCrawlerTooLowTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler ensor value too low for too long." + ::= { netBotzSNMPCrawlerSensorTraps 0 5 } + +netBotzSNMPCrawlerTooLowForTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler sensor value is no longer too low for too long." + ::= { netBotzSNMPCrawlerSensorTraps 0 105 } + +netBotzSNMPCrawlerUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler sensor unplugged." + ::= { netBotzSNMPCrawlerSensorTraps 0 6 } + +netBotzSNMPCrawlerReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler sensor no longer unplugged." + ::= { netBotzSNMPCrawlerSensorTraps 0 106 } + +netBotzSNMPCrawlerIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler sensor value increasing too quickly." + ::= { netBotzSNMPCrawlerSensorTraps 0 8 } + +netBotzSNMPCrawlerNotIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler sensor value no longer increasing too quickly." + ::= { netBotzSNMPCrawlerSensorTraps 0 108 } + +netBotzSNMPCrawlerDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler sensor value decreasing too quickly." + ::= { netBotzSNMPCrawlerSensorTraps 0 9 } + +netBotzSNMPCrawlerNotDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler sensor value no longer decreasing too quickly." + ::= { netBotzSNMPCrawlerSensorTraps 0 109 } + +netBotzSNMPCrawlerError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler sensor error." + ::= { netBotzSNMPCrawlerSensorTraps 0 1 } + +netBotzSNMPCrawlerErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler sensor error resolved." + ::= { netBotzSNMPCrawlerSensorTraps 0 101 } + +netBotzSNMPCrawlerSensorValueError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler Sensor sensor value error." + ::= { netBotzSNMPCrawlerSensorTraps 0 10 } + +netBotzSNMPCrawlerSensorValueErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "SNMP Crawler Sensor sensor value error resolved." + ::= { netBotzSNMPCrawlerSensorTraps 0 110 } + +netBotzGPSStatusSensorUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Status Sensor sensor unplugged." + ::= { netBotzGPSStatusSensorTraps 0 6 } + +netBotzGPSStatusSensorReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Status Sensor sensor no longer unplugged." + ::= { netBotzGPSStatusSensorTraps 0 106 } + +netBotzGPSStatusSensorError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Status Sensor sensor error." + ::= { netBotzGPSStatusSensorTraps 0 1 } + +netBotzGPSStatusSensorErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Status Sensor sensor error resolved." + ::= { netBotzGPSStatusSensorTraps 0 101 } + +netBotzGPSStatusSensorValueError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Status Sensor sensor value error." + ::= { netBotzGPSStatusSensorTraps 0 10 } + +netBotzGPSStatusSensorValueErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "GPS Status Sensor sensor value error resolved." + ::= { netBotzGPSStatusSensorTraps 0 110 } + +netBotzWirelessStatusSensorUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Wireless Status Sensor sensor unplugged." + ::= { netBotzWirelessStatusSensorTraps 0 6 } + +netBotzWirelessStatusSensorReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Wireless Status Sensor sensor no longer unplugged." + ::= { netBotzWirelessStatusSensorTraps 0 106 } + +netBotzWirelessStatusSensorError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Wireless Status Sensor sensor error." + ::= { netBotzWirelessStatusSensorTraps 0 1 } + +netBotzWirelessStatusSensorErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Wireless Status Sensor sensor error resolved." + ::= { netBotzWirelessStatusSensorTraps 0 101 } + +netBotzWirelessStatusSensorValueError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Wireless Status Sensor sensor value error." + ::= { netBotzWirelessStatusSensorTraps 0 10 } + +netBotzWirelessStatusSensorValueErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Wireless Status Sensor sensor value error resolved." + ::= { netBotzWirelessStatusSensorTraps 0 110 } + +netBotzPlugModuleStatusSensorUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Power Control plug module unplugged." + ::= { netBotzPlugModuleStatusSensorTraps 0 6 } + +netBotzPlugModuleStatusSensorReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Power Control plug module no longer unplugged." + ::= { netBotzPlugModuleStatusSensorTraps 0 106 } + +netBotzPlugModuleStatusSensorError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Power Control plug module error." + ::= { netBotzPlugModuleStatusSensorTraps 0 1 } + +netBotzPlugModuleStatusSensorErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Power Control plug module error resolved." + ::= { netBotzPlugModuleStatusSensorTraps 0 101 } + +netBotzPlugModuleStatusSensorValueError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Power Control plug module value error." + ::= { netBotzPlugModuleStatusSensorTraps 0 10 } + +netBotzPlugModuleStatusSensorValueErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Power Control plug module value error resolved." + ::= { netBotzPlugModuleStatusSensorTraps 0 110 } + +netBotzOutputControlSensorUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Output Control Sensor unplugged." + ::= { netBotzOutputControlSensorTraps 0 6 } + +netBotzOutputControlSensorReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Output Control Sensor no longer unplugged." + ::= { netBotzOutputControlSensorTraps 0 106 } + +netBotzOutputControlSensorError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Output Control Sensor error." + ::= { netBotzOutputControlSensorTraps 0 1 } + +netBotzOutputControlSensorErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Output Control Sensor error resolved." + ::= { netBotzOutputControlSensorTraps 0 101 } + +netBotzOutputControlSensorValueError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Output Control Sensor value error." + ::= { netBotzOutputControlSensorTraps 0 10 } + +netBotzOutputControlSensorValueErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Output Control Sensor value error resolved." + ::= { netBotzOutputControlSensorTraps 0 110 } + + +netBotzMultiRAESensorTooHigh NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE sensor value too high." + ::= { netBotzMultiRAESensorTraps 0 2 } + +netBotzMultiRAESensorTooHighRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE sensor value is no longer too high." + ::= { netBotzMultiRAESensorTraps 0 102 } + +netBotzMultiRAESensorTooLow NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE sensor value too low." + ::= { netBotzMultiRAESensorTraps 0 3 } + +netBotzMultiRAESensorTooLowRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE sensor value is no longer too low." + ::= { netBotzMultiRAESensorTraps 0 103 } + +netBotzMultiRAESensorTooHighTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE sensor value too high for too long." + ::= { netBotzMultiRAESensorTraps 0 4 } + +netBotzMultiRAESensorTooHighTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE sensor value is no longer too high for too long." + ::= { netBotzMultiRAESensorTraps 0 104 } + +netBotzMultiRAESensorTooLowTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE ensor value too low for too long." + ::= { netBotzMultiRAESensorTraps 0 5 } + +netBotzMultiRAESensorTooLowForTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE sensor value is no longer too low for too long." + ::= { netBotzMultiRAESensorTraps 0 105 } + +netBotzMultiRAESensorUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE sensor unplugged." + ::= { netBotzMultiRAESensorTraps 0 6 } + +netBotzMultiRAESensorReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE sensor no longer unplugged." + ::= { netBotzMultiRAESensorTraps 0 106 } + +netBotzMultiRAESensorIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE sensor value increasing too quickly." + ::= { netBotzMultiRAESensorTraps 0 8 } + +netBotzMultiRAESensorNotIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE sensor value no longer increasing too quickly." + ::= { netBotzMultiRAESensorTraps 0 108 } + +netBotzMultiRAESensorDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE sensor value decreasing too quickly." + ::= { netBotzMultiRAESensorTraps 0 9 } + +netBotzMultiRAESensorNotDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE sensor value no longer decreasing too quickly." + ::= { netBotzMultiRAESensorTraps 0 109 } + +netBotzMultiRAESensorError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE sensor error." + ::= { netBotzMultiRAESensorTraps 0 1 } + +netBotzMultiRAESensorErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE sensor error resolved." + ::= { netBotzMultiRAESensorTraps 0 101 } + +netBotzMultiRAESensorSensorValueError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE Sensor sensor value error." + ::= { netBotzMultiRAESensorTraps 0 10 } + +netBotzMultiRAESensorSensorValueErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE Sensor sensor value error resolved." + ::= { netBotzMultiRAESensorTraps 0 110 } + + +netBotzMultiRAESensorStatusUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE Sensor Status unplugged." + ::= { netBotzMultiRAESensorStatusTraps 0 6 } + +netBotzMultiRAESensorStatusReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE Sensor Status no longer unplugged." + ::= { netBotzMultiRAESensorStatusTraps 0 106 } + +netBotzMultiRAESensorStatusError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE Sensor Status error." + ::= { netBotzMultiRAESensorStatusTraps 0 1 } + +netBotzMultiRAESensorStatusErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE Sensor Status error resolved." + ::= { netBotzMultiRAESensorStatusTraps 0 101 } + +netBotzMultiRAESensorStatusValueError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE Sensor Status value error." + ::= { netBotzMultiRAESensorStatusTraps 0 10 } + +netBotzMultiRAESensorStatusValueErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE Sensor Status value error resolved." + ::= { netBotzMultiRAESensorStatusTraps 0 110 } + + +netBotzMultiRAEDeviceStatusUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE Device Status unplugged." + ::= { netBotzMultiRAEDeviceStatusTraps 0 6 } + +netBotzMultiRAEDeviceStatusReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE Device Status no longer unplugged." + ::= { netBotzMultiRAEDeviceStatusTraps 0 106 } + +netBotzMultiRAEDeviceStatusError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE Device Status error." + ::= { netBotzMultiRAEDeviceStatusTraps 0 1 } + +netBotzMultiRAEDeviceStatusErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE Device Status error resolved." + ::= { netBotzMultiRAEDeviceStatusTraps 0 101 } + +netBotzMultiRAEDeviceStatusValueError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE Device Status value error." + ::= { netBotzMultiRAEDeviceStatusTraps 0 10 } + +netBotzMultiRAEDeviceStatusValueErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "MultiRAE Device Status value error resolved." + ::= { netBotzMultiRAEDeviceStatusTraps 0 110 } + +netBotzLinkStatusSensorUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Link Status sensor unplugged." + ::= { netBotzLinkStatusSensorTraps 0 6 } + +netBotzLinkStatusSensorReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Link Status sensor no longer unplugged." + ::= { netBotzLinkStatusSensorTraps 0 106 } + +netBotzLinkStatusSensorError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Link Status sensor error." + ::= { netBotzLinkStatusSensorTraps 0 1 } + +netBotzLinkStatusSensorErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Link Status sensor error resolved." + ::= { netBotzLinkStatusSensorTraps 0 101 } + +netBotzLinkStatusSensorValueError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Link Status sensor value error." + ::= { netBotzLinkStatusSensorTraps 0 10 } + +netBotzLinkStatusSensorValueErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Link Status sensor value error resolved." + ::= { netBotzLinkStatusSensorTraps 0 110 } + +netBotzLoopVoltageTooHigh NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor value too high." + ::= { netBotzLoopVoltageSensorTraps 0 2 } + +netBotzLoopVoltageTooHighRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor value is no longer too high." + ::= { netBotzLoopVoltageSensorTraps 0 102 } + +netBotzLoopVoltageTooLow NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor value too low." + ::= { netBotzLoopVoltageSensorTraps 0 3 } + +netBotzLoopVoltageTooLowRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor value is no longer too low." + ::= { netBotzLoopVoltageSensorTraps 0 103 } + +netBotzLoopVoltageTooHighTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor value too high for too long." + ::= { netBotzLoopVoltageSensorTraps 0 4 } + +netBotzLoopVoltageTooHighTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor value is no longer too high for too long." + ::= { netBotzLoopVoltageSensorTraps 0 104 } + +netBotzLoopVoltageTooLowTooLong NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor value too low for too long." + ::= { netBotzLoopVoltageSensorTraps 0 5 } + +netBotzLoopVoltageTooLowForTooLongRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor value is no longer too low for too long." + ::= { netBotzLoopVoltageSensorTraps 0 105 } + +netBotzLoopVoltageUnplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor unplugged." + ::= { netBotzLoopVoltageSensorTraps 0 6 } + +netBotzLoopVoltageReplugged NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor no longer unplugged." + ::= { netBotzLoopVoltageSensorTraps 0 106 } + +netBotzLoopVoltageIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor value increasing too quickly." + ::= { netBotzLoopVoltageSensorTraps 0 8 } + +netBotzLoopVoltageNotIncreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor value no longer increasing too quickly." + ::= { netBotzLoopVoltageSensorTraps 0 108 } + +netBotzLoopVoltageDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor value decreasing too quickly." + ::= { netBotzLoopVoltageSensorTraps 0 9 } + +netBotzLoopVoltageNotDecreasingTooQuickly NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor value no longer decreasing too quickly." + ::= { netBotzLoopVoltageSensorTraps 0 109 } + +netBotzLoopVoltageError NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor error." + ::= { netBotzLoopVoltageSensorTraps 0 1 } + +netBotzLoopVoltageErrorRTN NOTIFICATION-TYPE + OBJECTS { + netBotzTrapErrorID, + netBotzTrapErrorType, + netBotzTrapErrorTypeLabel, + netBotzTrapSensorID, + netBotzTrapSensorLabel, + netBotzTrapPodID, + netBotzTrapPodLabel, + netBotzTrapPortID, + netBotzTrapPortLabel, + netBotzTrapStartTime, + netBotzTrapNotifyTime, + netBotzTrapResolveTime, + netBotzTrapSeverity, + netBotzTrapSensorValue, + netBotzTrapSensorValueInt, + netBotzTrapSensorValueFraction + } + STATUS current + DESCRIPTION + "Loop Voltage sensor error resolved." + ::= { netBotzLoopVoltageSensorTraps 0 101 } + +END diff --git a/MIBs/powernet412_mib.txt b/MIBs/powernet412_mib.txt new file mode 100644 index 0000000..6520621 --- /dev/null +++ b/MIBs/powernet412_mib.txt @@ -0,0 +1,70998 @@ +-- ************************************************************************* +-- AMERICAN POWER CONVERSION PowerNet-MIB +-- ************************************************************************* +-- Copyright (c) 2014 American Power Conversion, Inc. +-- PowerNet is a Trademark of American Power Conversion Corp. +-- +-- Title: APC TOP LEVEL PowerNet MIB +-- +-- Version : 4.1.2 +-- +-- Generated by script: tomib.awk +-- +-- Input File: powernetPS.mib +-- +-- Created: Tuesday, August, 19, 2014 +-- +-- Revision History: +-- ************************************************************************* + +-- - v3.2.0 Added functionality for MasterSwitch Plus +-- - v3.3.0 Added functionality for MX28B (dcDM3) and 3-phase UPS +-- - v3.3.2 New traps for Symmetra PX UPS +-- 07/15/01 - v3.4.0 Added transfer switch +-- - v3.4.3 Added functionality for External and Integrated Environmental Monitor +-- 06/14/02 - v3.4.4 Added dcmim2(Siemens) branch, Battery Manager(Reading) traps, and +-- Psx Traps for PDU and RM-PDU and Netlock branch/traps +-- 12/13/02 - v3.5.0 netlock - Initial support for netlock (nl). Traps 261-265 added. +-- rPDU - Initial support for rPDU. Traps 266-283 added. +-- rARU - Initial support for rARU. +-- gateway - Initial support for gateway (gw). Traps 230-260, 284-297 added. +-- ups - upsSyncCtrlGroup and upsState sections added. +-- 02/19/03 - v3.6.0 ups - UpsOutletGroups section added. Traps 298-299 added. +-- smw - Traps 300-305 added. +-- rPDU - General OID description cleanups. +-- gw - Updated SNMP support for gw. +-- 05/21/03 - v3.6.1 ups - Updated SNMP support for ups. +-- ems - Environmental Management System OIDs renamed from gateway (gw). +-- raru - Updated SNMP support for raru. +-- 06/13/03 - v3.6.3 airFM - Initial support for airFM. Traps 306-311 added. +-- nl - Traps 261-265 removed. +-- 11/26/03 - v3.6.4 xPDU - Initial support for xPDU. Traps 312-344 added. +-- airPA - Initial support for airPA. Traps 306-311 modified for airPA use. +-- airFM - AirFMStatus OIDs cleaned up. +-- 03/19/04 - v3.6.5 rPDU - Updated SNMP support for rPDU. +-- airFM - AirFMGroup section added. +-- 05/13/04 - v3.6.6 ups - Added several upsAdvBattery OIDs. +-- ems - Added emsStatusHardwareStatus and emsHardwareState traps 345-346. +-- aru - Trap 228 redefined to aruDeviceConfigChange. +-- 08/04/04 - v3.6.7 ups - Added upsAdvConfigNumExternalBatteries and +-- upsAdvConfigSimpleSignalShutdowns. +-- ce - Custom Event traps 347-352 added. +-- 11/22/04 - v3.6.8 ems - Many emsProbeConfig and emsProbeStatus OIDs added. +-- ups - Traps 353-358 added. +-- env - Traps 359-374 added. +-- 01/26/05 - v3.6.9 battman - Initial support for battman, traps 375-380 added. +-- xATS - Initial support for xATS, traps 381-478 added. +-- generator - Initial support for generator. +-- rPDU - Trap edits. +-- xPDU - Trap edits. +-- 05/26/05 - v3.7.0 consolePortServer - Initial support for consolePortServer (cpsAP930x). +-- xPDU - Cleaned up many descriptions. +-- xATS - Cleaned up many descriptions. +-- ups - Added several upsAdvConfig OIDs. +-- 09/28/05 - v3.8.0 modEnvMgr - Initial support for modEnvMgr (mem). +-- rARU - Added functionality for Gen 2 ARU. +-- ups/aru/mem - Traps 500-569 added. +-- all - General cleanup on typos and spelling errors. +-- 01/04/06 - v3.8.1 rARU - Added functionality for Gen 2 ARU +-- 02/22/06 - v3.8.2 accessControl - Initial support for accessControl. +-- Traps 570-592 added. +-- accessPX - Initial support for accessPX. +-- airIR - Initial support for airIR and airIRAlarms. +-- airIRRC - Initial support for airIRRC. +-- 05/24/06 - v3.8.4 apcLocalDisplay - Initial support for apcLocalDisplay. +-- ups - UpsAdvOutputRedundancy, upsAdvOutputKVACapacity, +-- upsAdvConfigBasicSignalLowBatteryDuration, and +-- upsAdvConfigBypassPhaseLockRequired OIDs added. +-- UpsAdvConfigMinReturnRuntime SYNTAX changed. +-- UPS trap numbers 600-623 added. +-- em - New emConfigProbe, emConfigContact, emStatusProbe OIDs added. +-- iem - New iemConfigProbe, iemConfigContact, iemStatusProbe OIDs added. +-- 08/31/06 - v3.8.5 airIRSC - Initial support for airIRSC. +-- XPDU - XPDUBranchBreaker OIDs and xPDUBranchCurrent traps added. +-- 11/03/06 - v3.8.6 rPDU - Updated SNMP support for rPDU. +-- accessPX - accessPXConfigCardFormat OID added. +-- airIRSC - airIRSCUnitStatusCompressor added. +-- 01/03/07 - v3.8.7 airIRRP - Initial support for airIRRP100 and airIRRP500. +-- 04/06/07 - v3.8.8 battMan - Updated SNMP support for Battery Manager, +-- battManConfigApplication OID deprecated. +-- airIRRP - Added HeatAssistEnable to airIRRP100 and airIRRP500. +-- ups - Added several upsDiagSubSys OIDs. +-- iem - Added iemStatusProbeLocation OID. +-- all - Cleaned up version history section. +-- 12/19/07 - v3.9.1 airFM - Added full SNMP support, deprecating some existing OIDs in +-- favor of new structure. +-- 12/19/07 - v3.9.2 Added new OIDs for isxModularDistribution, isxModularPdu, airInRoomPerimeter +-- airIRGen2, symmetraPX IDs, isxServers IDs, upsAdvConfig, upsDiagSubSysNetworkComCard, +-- memInputsCommStatus, airIRRP100GroupSetpoints. Added new SNMP Traps for +-- ISX Modular Distribution, and xATS. +-- 08/13/08 - v3.9.3 Added new OIDs for UPS HighPrec OIDs: +-- upsHighPrecBattery, upsHighPrecInput, and upsHighPrecOutput. +-- Added new OIDs for the 10kW the AIR IR Gen2: +-- airIRG2RDT2ConfigUnitRoleOverride, airIRG2RDT2RunHoursUnit, +-- airIRG2GroupConfigNumberofBackupUnits, airIRG2GroupConfigRuntimeBalancingEnable, +-- and airIRG2GroupConfigLoadAssistEnable for use by 10kW application. +-- Added new traps apcInternalCommunicationFault and apcInternalCommunicationFaultCleared +-- for use by the SUMX application. +-- Updated descriptions in existing OIDs. +-- 09/25/08 - v3.9.4 Added new OIDs for Symmetra PX: +-- upsParallelSystem, upsPhysicalLayout, upsAdvConfigMainsSetting, upsAdvConfigACWiringSetting, +-- upsAdvConfigUpperOutputVoltTolerance, upsAdvConfigLowerOutputVoltTolerance, upsAdvConfigUpperBypassVoltTolerance +-- upsAdvConfigLowerBypassVoltTolerance, upsAdvConfigOutofSyncBypassTransferDelay, upsAdvTestDiagnosticTime +-- upsAdvTestDiagnosticDay, upsDiagSwitchGearBypassInputSwitchStatus, upsDiagSubFeedBreakerTable, +-- upsDiagSubFeedBreakerTable, upsSideCarFrameLayoutTable, upsPowerFrameLayoutTable +-- Added new OIDs for UPSs: +-- upsBasicSystemStatus, upsAdvControlFlashAndBeep (appended new list options) +-- Added new OIDs for the AC RP10kW: +-- airIRG2RDT2ConfigUnitIdleOnCoolFail +-- Added new OID for isxModularPDU device: +-- isxModularPduDeviceTransformerPresent (appended new list option) +-- 02/24/09 - v3.9.5 Added new OIDs for the UPS Integrated ATS product, Air IRSC product, added new Traps for UPS support +-- and fixed MIB compilier warnings. +-- 02/24/09 - v3.9.6 Added new Traps and mtrapargs for the ISXC Trap Notification support. +-- 09/18/09 - v3.9.8 Added new OIDs for the InRoom C7000 Air product. +-- 04/14/10 - v3.9.9 Added new rPDU2 device and modified some rPDU OIDs. +-- 06/22/10 - v4.0.0 Added traps 638 through 651 to support ATS. +-- Updated control OIDs for rPDU2g +-- Updates to support PX100kW UPS. +-- Added traps 756 and 757 to support PX100kW UPS. +-- Added upsAdvBattery, upsHighPrecBattery, and upsDiagBattery OIDs to support PX250kW/PX500kW UPS. +-- 06/30/10 - v4.0.1 Added new OID's upsAdvBatteryFullCapacity, upsAdvInputNominalFrequency, upsAdvInputNominalVoltage, +-- upsAdvInputBypassNominalFrequency, upsAdvInputBypassNominalVoltage, upsBasicSystemInternalTemperature, +-- upsAdvOutputNominalFrequency, upsAdvOutputActivePower and upsAdvOutputApparentPower. +-- Added traps 734 to 739 to support Galaxy 300 and Galaxy 7000 UPS. +-- Added SyOid's galaxy300UPS10kVA33, galaxy300UPS15kVA33, galaxy300UPS20kVA33, +-- galaxy300UPS30kVA33, galaxy300UPS40kVA33, galaxy300UPS10kVA31, galaxy300UPS15kVA31, +-- galaxy300UPS20kVA31 and galaxy300UPS30kVA31,galaxy7000UPS200kVA,galaxy7000UPS250kVA, +-- galaxy7000UPS300kVA,galaxy7000UPS400kVA,galaxy7000UPS500kVA,galaxy7000SSC800kVA, +-- galaxy7000SSC1200kVA and galaxy7000SSC2000kVA. +-- 10/27/10 - v4.0.2 Added Idle on Cool Fail and Fan Speed Control OIDs for the InRow ACRC. +-- Added new OID's for Odin UPS upsAdvInputStatisticsTable, upsAdvInputApparentPower, +-- upsAdvInputVoltageTHD, upsAdvInputBypassVoltageTHD, upsAdvInputPeakCurrent, upsAdvInputBypassPeakCurrent, +-- upsAdvOutputStatisticsTable, upsAdvOutputPeakCurrent, upsAdvOutputCurrentTHD, upsAdvOutputCrestFactor, +-- upsAdvStateTotaltimeonbattery, upsAdvStateTotaltimeonbypass, upsAdvStateTotaltimeonNormal, +-- upsAdvStateNumberoftimesonbattery, upsAdvStateNumberoftimesbypass, upsAdvStateNumberoftimesNormal, +-- subfeedBreakerUpperAcceptPowerCritical, upsParallelInputMaximumCurrent, upsParallelTotalOutputPower, +-- upsParallelTotalOutputApparentPower, upsParallelInputCurrent, upsParallelInputActivePower, +-- upsParallelInputApparentPower, upsParallelInputVoltage, upsParallelInputMaxVoltage, +-- upsParallelInputMaxCurrent, upsParallelInputTotalActivePower, upsParallelInputTotalApparentPower, +-- upsParallelOutputCurrent, upsParallelOutputLoad, upsParallelOutputPercentLoad, upsParallelOutputPower, +-- upsParallelOutputApparentPower, upsParallelDiagSubSysBreakerStatus, upsParallelDiagSubSysBreakerName +-- and upsParallelOutputTotalPercentLoad. +-- Modified the OID upsAdvConfigOutputFreqRange and upsParallelSysRedundancy. +-- 01/13/11 - v4.0.3 Added new oids, upsHighPrecOutputEfficiency and upsHighPrecOutputEnergyUsage. +-- Added green mode for bit 51 of upsBasicStateOutputState. +-- Added traps 758 to 763 to support UPS firmware update. +-- Deprecated all OIDs off branch mfiletransfer +-- Added rPDU2 Metered Outlet Data +-- 08/17/11 - v4.0.4 Updated several rPDU2 and rPDU OIDs. +-- 12/07/11 - v4.0.5 Added new OID's for SYPX upsPhaseOutputPowerFactor and symmetraPxDisplay. +-- Added SYS OID's for different Caphorn models galaxy5000UPS20KVA, galaxy5000UPS30KVA, galaxy5000UPS40KVA +-- galaxy5000UPS50KVA, galaxy5000UPS60KVA , galaxy5000UPS80KVA, galaxy5000UPS100KVA, galaxy5000UPS120KVA +-- galaxy5000UPS130KVA, galaxy5500UPS20KVA, galaxy5500UPS30KVA, galaxy5500UPS40KVA, galaxy5500UPS50KVA +-- galaxy5500UPS60KVA, galaxy5500UPS80KVA, galaxy5500UPS100KVA, galaxy5500UPS120KVA, galaxy5500UPS130KVA +-- and new OID upsAdvStateEcomode +-- 06/05/12 - v4.0.6 Added new OID rPDUIdentDeviceLineToNeutralVoltage for AP7823 Rack PDU. +-- 06/20/12 - v4.0.6 Added new rPDU2Group OID table for AP84xx, AP86xx, AP88xx, AP89xx Rack PDUs. +-- 08/10/12 - v4.0.6 Added new OIDs for SYPX 250/500 upsAdvConfigWarningAlarmDelay, upsAdvConfigInformationalAlarmDelay, upsDiagSwitchGearInstallationLoadPct, +-- upsParallelOutputActivePowerTable,upsParallelSysSwitchGearInstallationLoadPct, upsParallelSysRedundancyStatus and upsParallelSysName. +-- Modified the description for upsBasicBatteryLastReplaceDate and bit 51 of upsBasicStateOutputState. +-- Updated upsBasicOutputStatus and upsBasicSystemStatus. +-- 08/10/12 - v4.0.6 Added SYS OIDs for different Caphorn models galaxy9000UPS, galaxy9000SSC, galaxy9000UPSWithSSC, galaxy9000FreqConverter, eps6000UPS, +-- eps6000SSC, eps6000UPSWithSSC, eps6000FreqConverter, eps7000UPS, eps7000SSC, eps7000UPSWithSSC, +-- eps7000FreqConverter, eps8000UPS, eps8000SSC, eps8000UPSWithSSC, eps8000FreqConverter. +-- Modified the description for bits 53 to 56 of upsBasicStateOutputState. +-- 02/22/13 -v4.0.8 Added OIDs upsAdvBatteryInternalSKU, upsAdvBatteryExternalSKU, upsAdvBatteryRecommendedReplaceDate, +-- upsAdvConfigGreenMode, upsAdvConfigLCDLocalLanguage, upsAdvConfigLCDLockOut, +-- upsAdvConfigChargerRate, and upsAdvConfigBatterySelection for the SUMX application. +-- 04/10/13 -v4.0.9 Added new SYS OID for sPDU masterSwitchsPDU +-- 10/18/13 -v4.1.0 Added new cooling section of OIDs for second generation cooling products. +-- 02/17/14 -v4.1.1 Added the OIDs for Valhal(Galaxy VM)UPS. +-- 08/11/14 -v4.1.2 Added upsHighPrecBatteryPacks category. +-- Added upsHighPrecInputBypassVoltage and upsHighPrecInputBypassFrequency OIDs. +-- Added traps upsLocalDisplayButtonFault, upsLocalDisplayButtonFaultCleared, upsNeedsFactorySetupFault, +-- upsNeedsFactorySetupFaultCleared, upsEPOActive, upsEPOActiveCleared, upsFirmwareMismatch, upsFirmwareMismatchCleared, +-- upsOscillatorFailed, and upsOscillatorFailedCleared +-- Updated the description for upsHighPrecOutputEfficiency to display all currently defined error conditions. + +-- ******************************************************************************************** +-- ******************************************************************************************** +-- PowerNet-MIB { iso org(3) dod(6) internet(1) private(4) +-- enterprises(1) apc(318) } + +PowerNet-MIB DEFINITIONS ::= BEGIN + +IMPORTS + enterprises, IpAddress, Gauge, TimeTicks FROM RFC1155-SMI + DisplayString FROM RFC1213-MIB + OBJECT-TYPE FROM RFC-1212 + TRAP-TYPE FROM RFC-1215; +-- IMPORTS End + +apc OBJECT IDENTIFIER ::= { enterprises 318 } + +products OBJECT IDENTIFIER ::= { apc 1 } +apcmgmt OBJECT IDENTIFIER ::= { apc 2 } + +hardware OBJECT IDENTIFIER ::= { products 1 } +software OBJECT IDENTIFIER ::= { products 2 } +system OBJECT IDENTIFIER ::= { products 3 } +experimental OBJECT IDENTIFIER ::= { products 4 } + +mconfig OBJECT IDENTIFIER ::= { apcmgmt 1 } +mcontrol OBJECT IDENTIFIER ::= { apcmgmt 2 } +mtrapargs OBJECT IDENTIFIER ::= { apcmgmt 3 } +mfiletransfer OBJECT IDENTIFIER ::= { apcmgmt 4 } + +mconfigClock OBJECT IDENTIFIER ::= { mconfig 6 } + +mfiletransferStatus OBJECT IDENTIFIER ::= { mfiletransfer 1 } +mfiletransferConfig OBJECT IDENTIFIER ::= { mfiletransfer 2 } +mfiletransferControl OBJECT IDENTIFIER ::= { mfiletransfer 3 } + +mfiletransferConfigSettings OBJECT IDENTIFIER ::= { mfiletransferConfig 1 } +mfiletransferConfigTFTP OBJECT IDENTIFIER ::= { mfiletransferConfig 2 } +mfiletransferConfigFTP OBJECT IDENTIFIER ::= { mfiletransferConfig 3 } + +ups OBJECT IDENTIFIER ::= { hardware 1 } +measureUps OBJECT IDENTIFIER ::= { hardware 2 } +miniSNMPadapter OBJECT IDENTIFIER ::= { hardware 3 } +masterswitch OBJECT IDENTIFIER ::= { hardware 4 } +masterswitchVM OBJECT IDENTIFIER ::= { hardware 5 } +masterswitchMSP OBJECT IDENTIFIER ::= { hardware 6 } +dcDM3 OBJECT IDENTIFIER ::= { hardware 7 } +automaticTransferSwitch OBJECT IDENTIFIER ::= { hardware 8 } +dc2 OBJECT IDENTIFIER ::= { hardware 9 } +environmentalMonitor OBJECT IDENTIFIER ::= { hardware 10 } +netlock OBJECT IDENTIFIER ::= { hardware 11 } +rPDU OBJECT IDENTIFIER ::= { hardware 12 } +airConditioners OBJECT IDENTIFIER ::= { hardware 13 } +rARU OBJECT IDENTIFIER ::= { hardware 14 } +xPDU OBJECT IDENTIFIER ::= { hardware 15 } +battMan OBJECT IDENTIFIER ::= { hardware 16 } +xATS OBJECT IDENTIFIER ::= { hardware 17 } +generator OBJECT IDENTIFIER ::= { hardware 18 } +consolePortServer OBJECT IDENTIFIER ::= { hardware 19 } +accessControl OBJECT IDENTIFIER ::= { hardware 20 } +apcLocalDisplay OBJECT IDENTIFIER ::= { hardware 21 } +isxModularDistribution OBJECT IDENTIFIER ::= { hardware 22 } +isxModularPdu OBJECT IDENTIFIER ::= { hardware 23 } + + +universalInputOutput OBJECT IDENTIFIER ::= { hardware 25 } + +rPDU2 OBJECT IDENTIFIER ::= { hardware 26 } + + +cooling OBJECT IDENTIFIER ::= { hardware 27 } + + +powerNetSubAgent OBJECT IDENTIFIER ::= { software 1 } + +struxureWareOperations OBJECT IDENTIFIER ::= { software 2 } +struxureWareOperationsStatus OBJECT IDENTIFIER ::= { struxureWareOperations 1 } + +powerNetSoftwareSystem OBJECT IDENTIFIER ::= { powerNetSubAgent 1 } +powerNetSoftwareConfig OBJECT IDENTIFIER ::= { powerNetSubAgent 2 } + +backUPS OBJECT IDENTIFIER ::= { system 1 } +smartUPS OBJECT IDENTIFIER ::= { system 2 } +matrixUPS OBJECT IDENTIFIER ::= { system 3 } +masterSwitch OBJECT IDENTIFIER ::= { system 4 } +symmetraUPS OBJECT IDENTIFIER ::= { system 5 } +dp100E OBJECT IDENTIFIER ::= { system 6 } +dp300E OBJECT IDENTIFIER ::= { system 7 } +monitors OBJECT IDENTIFIER ::= { system 8 } +redundantSwitch OBJECT IDENTIFIER ::= { system 9 } +dcPower OBJECT IDENTIFIER ::= { system 10 } +automaticXferSwitch OBJECT IDENTIFIER ::= { system 11 } +netLock OBJECT IDENTIFIER ::= { system 12 } +symmetra3PhaseUPS OBJECT IDENTIFIER ::= { system 13 } +networkAir OBJECT IDENTIFIER ::= { system 14 } +infraStruXurePDU OBJECT IDENTIFIER ::= { system 15 } +ais5000UPS OBJECT IDENTIFIER ::= { system 16 } +smartUPS3Phase OBJECT IDENTIFIER ::= { system 17 } +battManager OBJECT IDENTIFIER ::= { system 18 } +infraStruXureATS OBJECT IDENTIFIER ::= { system 19 } +conPortServ OBJECT IDENTIFIER ::= { system 20 } +gutor OBJECT IDENTIFIER ::= { system 21 } +accControl OBJECT IDENTIFIER ::= { system 22 } +symmetraPX OBJECT IDENTIFIER ::= { system 23 } +isxModDistribution OBJECT IDENTIFIER ::= { system 24 } +isxServers OBJECT IDENTIFIER ::= { system 25 } +smartUPS2 OBJECT IDENTIFIER ::= { system 27 } +galaxy OBJECT IDENTIFIER ::= { system 28 } + +eps OBJECT IDENTIFIER ::= { system 30 } + +battManIdent OBJECT IDENTIFIER ::= { battMan 1 } +battManSystemCalib OBJECT IDENTIFIER ::= { battMan 2 } +battManUnitCalib OBJECT IDENTIFIER ::= { battMan 3 } +battManStringCalib OBJECT IDENTIFIER ::= { battMan 4 } +battManBatteryCalib OBJECT IDENTIFIER ::= { battMan 5 } +battManConfig OBJECT IDENTIFIER ::= { battMan 6 } +battManAlarm OBJECT IDENTIFIER ::= { battMan 7 } +battManSystemStatus OBJECT IDENTIFIER ::= { battMan 8 } +battManStringStatus OBJECT IDENTIFIER ::= { battMan 9 } +battManBatteryStatus OBJECT IDENTIFIER ::= { battMan 10 } +battManInputContactStatus OBJECT IDENTIFIER ::= { battMan 11 } +battManControl OBJECT IDENTIFIER ::= { battMan 12 } +battManTestResults OBJECT IDENTIFIER ::= { battMan 13 } +battManUnitStatus OBJECT IDENTIFIER ::= { battMan 14 } + +xPDUIdent OBJECT IDENTIFIER ::= { xPDU 1 } +xPDUDevice OBJECT IDENTIFIER ::= { xPDU 2 } +xPDUACMonitoringPoint OBJECT IDENTIFIER ::= { xPDU 3 } +xPDUCircuitBreakers OBJECT IDENTIFIER ::= { xPDU 4 } +xPDUInputContacts OBJECT IDENTIFIER ::= { xPDU 5 } +xPDUOutputRelays OBJECT IDENTIFIER ::= { xPDU 6 } +xPDUMiscGroup OBJECT IDENTIFIER ::= { xPDU 7 } + +xPDUMainInput OBJECT IDENTIFIER ::= { xPDUACMonitoringPoint 1 } +xPDUBypassInput OBJECT IDENTIFIER ::= { xPDUACMonitoringPoint 2 } +xPDUUPSInput OBJECT IDENTIFIER ::= { xPDUACMonitoringPoint 3 } +xPDUSystemOutput OBJECT IDENTIFIER ::= { xPDUACMonitoringPoint 4 } +xPDUGroundMonitorPoint OBJECT IDENTIFIER ::= { xPDUACMonitoringPoint 5 } + +xPDUSystemBreakers OBJECT IDENTIFIER ::= { xPDUCircuitBreakers 1 } +xPDUBranchBreakers OBJECT IDENTIFIER ::= { xPDUCircuitBreakers 2 } + +xATSIdent OBJECT IDENTIFIER ::= { xATS 1 } +xATSDevice OBJECT IDENTIFIER ::= { xATS 2 } +xATSSwitch OBJECT IDENTIFIER ::= { xATS 3 } +xATSACMonitoringPoint OBJECT IDENTIFIER ::= { xATS 4 } +xATSTesting OBJECT IDENTIFIER ::= { xATS 5 } +xATSInputContacts OBJECT IDENTIFIER ::= { xATS 6 } +xATSOutputRelays OBJECT IDENTIFIER ::= { xATS 7 } +xATSMisc OBJECT IDENTIFIER ::= { xATS 8 } + +xATSSwitchStatus OBJECT IDENTIFIER ::= { xATSSwitch 1 } +xATSSwitchSettings OBJECT IDENTIFIER ::= { xATSSwitch 2 } +xATSSwitchTimers OBJECT IDENTIFIER ::= { xATSSwitch 3 } +xATSSwitchBlockMap OBJECT IDENTIFIER ::= { xATSSwitch 4 } +xATSSwitchStatistics OBJECT IDENTIFIER ::= { xATSSwitch 5 } + +xATSSource1 OBJECT IDENTIFIER ::= { xATSACMonitoringPoint 1 } +xATSSource2 OBJECT IDENTIFIER ::= { xATSACMonitoringPoint 2 } +xATSSystemOutput OBJECT IDENTIFIER ::= { xATSACMonitoringPoint 3 } + +xATSTestingStatus OBJECT IDENTIFIER ::= { xATSTesting 1 } +xATSTestingResults OBJECT IDENTIFIER ::= { xATSTesting 2 } +xATSTestingSchedule OBJECT IDENTIFIER ::= { xATSTesting 3 } +xATSTestingSimulatePowerFail OBJECT IDENTIFIER ::= { xATSTesting 4 } + +xATSGenerator OBJECT IDENTIFIER ::= { generator 1 } + +xATSGeneratorIdent OBJECT IDENTIFIER ::= { xATSGenerator 1 } +xATSGeneratorStatus OBJECT IDENTIFIER ::= { xATSGenerator 2 } +xATSGeneratorAdvStatus OBJECT IDENTIFIER ::= { xATSGenerator 3 } +xATSGeneratorOutput OBJECT IDENTIFIER ::= { xATSGenerator 4 } +xATSGeneratorSettings OBJECT IDENTIFIER ::= { xATSGenerator 5 } +xATSGeneratorService OBJECT IDENTIFIER ::= { xATSGenerator 6 } +xATSGeneratorFuelSystem OBJECT IDENTIFIER ::= { xATSGenerator 7 } + +cpsAP930x OBJECT IDENTIFIER ::= { consolePortServer 1 } + +cpsAP930xSys OBJECT IDENTIFIER ::= { cpsAP930x 1 } +cpsAP930xConf OBJECT IDENTIFIER ::= { cpsAP930x 2 } +cpsAP930xInfo OBJECT IDENTIFIER ::= { cpsAP930x 3 } +cpsAP930xAdm OBJECT IDENTIFIER ::= { cpsAP930x 4 } + + + +smartUPS250 OBJECT IDENTIFIER ::= { smartUPS 1 } +smartUPS400 OBJECT IDENTIFIER ::= { smartUPS 2 } +smartUPS600 OBJECT IDENTIFIER ::= { smartUPS 3 } +smartUPS900 OBJECT IDENTIFIER ::= { smartUPS 4 } +smartUPS1250 OBJECT IDENTIFIER ::= { smartUPS 5 } +smartUPS2000 OBJECT IDENTIFIER ::= { smartUPS 6 } + +smartUPS450 OBJECT IDENTIFIER ::= { smartUPS 7 } +smartUPS700 OBJECT IDENTIFIER ::= { smartUPS 8 } +smartUPS1000 OBJECT IDENTIFIER ::= { smartUPS 9 } +smartUPS1400 OBJECT IDENTIFIER ::= { smartUPS 10 } +smartUPS2200 OBJECT IDENTIFIER ::= { smartUPS 11 } +smartUPS3000 OBJECT IDENTIFIER ::= { smartUPS 12 } +smartUPS5000 OBJECT IDENTIFIER ::= { smartUPS 13 } +smartUPS7500 OBJECT IDENTIFIER ::= { smartUPS 14 } +smartUPS10000 OBJECT IDENTIFIER ::= { smartUPS 15 } +smartUPS1500 OBJECT IDENTIFIER ::= { smartUPS 16 } +smartUPS3000DSP OBJECT IDENTIFIER ::= { smartUPS 17 } +smartUPS5000DSP OBJECT IDENTIFIER ::= { smartUPS 18 } +smartUPS8000 OBJECT IDENTIFIER ::= { smartUPS 19 } + +matrixUPS3000 OBJECT IDENTIFIER ::= { matrixUPS 1 } +matrixUPS5000 OBJECT IDENTIFIER ::= { matrixUPS 2 } + +masterSwitchV1 OBJECT IDENTIFIER ::= { masterSwitch 1} +masterSwitchV2 OBJECT IDENTIFIER ::= { masterSwitch 2} +masterSwitchVM OBJECT IDENTIFIER ::= { masterSwitch 3} +masterSwitchMSP OBJECT IDENTIFIER ::= { masterSwitch 4} +masterSwitchrPDU OBJECT IDENTIFIER ::= { masterSwitch 5} +masterSwitchrPDU2 OBJECT IDENTIFIER ::= { masterSwitch 6} +masterSwitchsPDU OBJECT IDENTIFIER ::= { masterSwitch 7} + +symmetraUPS4kVA OBJECT IDENTIFIER ::= { symmetraUPS 1 } +symmetraUPS8kVA OBJECT IDENTIFIER ::= { symmetraUPS 2 } +symmetraUPS12kVA OBJECT IDENTIFIER ::= { symmetraUPS 3 } +symmetraUPS16kVA OBJECT IDENTIFIER ::= { symmetraUPS 4 } + +environmental OBJECT IDENTIFIER ::= { monitors 1 } +environmentalMgtSystem OBJECT IDENTIFIER ::= { monitors 2 } +emu2 OBJECT IDENTIFIER ::= { monitors 3 } +mem OBJECT IDENTIFIER ::= { monitors 4 } + +dm3 OBJECT IDENTIFIER ::= { dcPower 1 } +dcmim2 OBJECT IDENTIFIER ::= { dcPower 2 } + +symmetra3PhaseUPS40kVA OBJECT IDENTIFIER ::= { symmetra3PhaseUPS 1 } +symmetra3PhaseUPS60kVA OBJECT IDENTIFIER ::= { symmetra3PhaseUPS 2 } +symmetra3PhaseUPS80kVA OBJECT IDENTIFIER ::= { symmetra3PhaseUPS 3 } +symmetra3PhaseUPS20kVA OBJECT IDENTIFIER ::= { symmetra3PhaseUPS 4 } + +airFMSeries OBJECT IDENTIFIER ::= { networkAir 1 } +rackAirRemovalUnit OBJECT IDENTIFIER ::= { networkAir 2 } +airPASeries OBJECT IDENTIFIER ::= { networkAir 3 } +airIRSC100Series OBJECT IDENTIFIER ::= { networkAir 4 } +airIRRC100Series OBJECT IDENTIFIER ::= { networkAir 5 } +airIRRP100Series OBJECT IDENTIFIER ::= { networkAir 6 } +airIRRP500Series OBJECT IDENTIFIER ::= { networkAir 7 } +airIRRD100Series OBJECT IDENTIFIER ::= { networkAir 8 } +airInRoomPerimeter OBJECT IDENTIFIER ::= { networkAir 9 } +airACRC300Series OBJECT IDENTIFIER ::= { networkAir 10 } +airIRRDU OBJECT IDENTIFIER ::= { networkAir 12 } + +ais5000UPS10kVA OBJECT IDENTIFIER ::= { ais5000UPS 1 } +ais5000UPS20kVA OBJECT IDENTIFIER ::= { ais5000UPS 2 } +ais5000UPS30kVA OBJECT IDENTIFIER ::= { ais5000UPS 3 } +ais5000UPS40kVA OBJECT IDENTIFIER ::= { ais5000UPS 4 } +ais5000UPS60kVA OBJECT IDENTIFIER ::= { ais5000UPS 5 } +ais5000UPS80kVA OBJECT IDENTIFIER ::= { ais5000UPS 6 } +ais5000UPS100kVA OBJECT IDENTIFIER ::= { ais5000UPS 7 } + +smartUPS3Phase10kVA OBJECT IDENTIFIER ::= { smartUPS3Phase 1 } +smartUPS3Phase15kVA OBJECT IDENTIFIER ::= { smartUPS3Phase 2 } +smartUPS3Phase20kVA OBJECT IDENTIFIER ::= { smartUPS3Phase 3 } +smartUPS3Phase30kVA OBJECT IDENTIFIER ::= { smartUPS3Phase 4 } +smartUPS3Phase40kVA OBJECT IDENTIFIER ::= { smartUPS3Phase 5 } + +galaxy7000UPS200kVA OBJECT IDENTIFIER ::= { galaxy 1 } +galaxy7000UPS250kVA OBJECT IDENTIFIER ::= { galaxy 2 } +galaxy7000UPS300kVA OBJECT IDENTIFIER ::= { galaxy 3 } +galaxy7000UPS400kVA OBJECT IDENTIFIER ::= { galaxy 4 } +galaxy7000UPS500kVA OBJECT IDENTIFIER ::= { galaxy 5 } +galaxy7000SSC800kVA OBJECT IDENTIFIER ::= { galaxy 6 } +galaxy7000SSC1200kVA OBJECT IDENTIFIER ::= { galaxy 7 } +galaxy7000SSC2000kVA OBJECT IDENTIFIER ::= { galaxy 8 } +galaxy300UPS10kVA33 OBJECT IDENTIFIER ::= { galaxy 9 } +galaxy300UPS15kVA33 OBJECT IDENTIFIER ::= { galaxy 10 } +galaxy300UPS20kVA33 OBJECT IDENTIFIER ::= { galaxy 11 } +galaxy300UPS30kVA33 OBJECT IDENTIFIER ::= { galaxy 12 } +galaxy300UPS40kVA33 OBJECT IDENTIFIER ::= { galaxy 13 } +galaxy300UPS10kVA31 OBJECT IDENTIFIER ::= { galaxy 14 } +galaxy300UPS15kVA31 OBJECT IDENTIFIER ::= { galaxy 15 } +galaxy300UPS20kVA31 OBJECT IDENTIFIER ::= { galaxy 16 } +galaxy300UPS30kVA31 OBJECT IDENTIFIER ::= { galaxy 17 } + +galaxy5000UPS20KVA OBJECT IDENTIFIER ::= { galaxy 18 } +galaxy5000UPS30KVA OBJECT IDENTIFIER ::= { galaxy 19 } +galaxy5000UPS40KVA OBJECT IDENTIFIER ::= { galaxy 20 } +galaxy5000UPS50KVA OBJECT IDENTIFIER ::= { galaxy 21 } +galaxy5000UPS60KVA OBJECT IDENTIFIER ::= { galaxy 22 } +galaxy5000UPS80KVA OBJECT IDENTIFIER ::= { galaxy 23 } +galaxy5000UPS100KVA OBJECT IDENTIFIER ::= { galaxy 24 } +galaxy5000UPS120KVA OBJECT IDENTIFIER ::= { galaxy 25 } +galaxy5000UPS130KVA OBJECT IDENTIFIER ::= { galaxy 26 } +galaxy5500UPS20KVA OBJECT IDENTIFIER ::= { galaxy 27 } +galaxy5500UPS30KVA OBJECT IDENTIFIER ::= { galaxy 28 } +galaxy5500UPS40KVA OBJECT IDENTIFIER ::= { galaxy 29 } +galaxy5500UPS50KVA OBJECT IDENTIFIER ::= { galaxy 30 } +galaxy5500UPS60KVA OBJECT IDENTIFIER ::= { galaxy 31 } +galaxy5500UPS80KVA OBJECT IDENTIFIER ::= { galaxy 32 } +galaxy5500UPS100KVA OBJECT IDENTIFIER ::= { galaxy 33 } +galaxy5500UPS120KVA OBJECT IDENTIFIER ::= { galaxy 34 } +galaxy5500UPS130KVA OBJECT IDENTIFIER ::= { galaxy 35 } + + + +galaxyVMUPS50kVA OBJECT IDENTIFIER ::= { galaxy 36 } +galaxyVMUPS60kVA OBJECT IDENTIFIER ::= { galaxy 37 } +galaxyVMUPS80kVA OBJECT IDENTIFIER ::= { galaxy 38 } +galaxyVMUPS90kVA OBJECT IDENTIFIER ::= { galaxy 39 } +galaxyVMUPS100kVA OBJECT IDENTIFIER ::= { galaxy 40 } +galaxyVMUPS110kVA OBJECT IDENTIFIER ::= { galaxy 41 } +galaxyVMUPS120kVA OBJECT IDENTIFIER ::= { galaxy 42 } +galaxyVMUPS130kVA OBJECT IDENTIFIER ::= { galaxy 43 } +galaxyVMUPS160kVA OBJECT IDENTIFIER ::= { galaxy 44 } +galaxyVMUPS180kVA OBJECT IDENTIFIER ::= { galaxy 45 } +galaxyVMUPS200kVA OBJECT IDENTIFIER ::= { galaxy 46 } +galaxyVMUPS225kVA OBJECT IDENTIFIER ::= { galaxy 47 } + + +galaxy9000UPS OBJECT IDENTIFIER ::= { galaxy 48 } +galaxy9000SSC OBJECT IDENTIFIER ::= { galaxy 49 } +galaxy9000UPSWithSSC OBJECT IDENTIFIER ::= { galaxy 50 } +galaxy9000FreqConverter OBJECT IDENTIFIER ::= { galaxy 51 } + + +eps6000UPS OBJECT IDENTIFIER ::= { eps 1 } +eps6000SSC OBJECT IDENTIFIER ::= { eps 2 } +eps6000UPSWithSSC OBJECT IDENTIFIER ::= { eps 3 } +eps6000FreqConverter OBJECT IDENTIFIER ::= { eps 4 } +eps7000UPS OBJECT IDENTIFIER ::= { eps 5 } +eps7000SSC OBJECT IDENTIFIER ::= { eps 6 } +eps7000UPSWithSSC OBJECT IDENTIFIER ::= { eps 7 } +eps7000FreqConverter OBJECT IDENTIFIER ::= { eps 8 } +eps8000UPS OBJECT IDENTIFIER ::= { eps 9 } +eps8000SSC OBJECT IDENTIFIER ::= { eps 10 } +eps8000UPSWithSSC OBJECT IDENTIFIER ::= { eps 11 } +eps8000FreqConverter OBJECT IDENTIFIER ::= { eps 12 } + + +conPortServAP930x OBJECT IDENTIFIER ::= { conPortServ 1 } + +gutorPEW OBJECT IDENTIFIER ::= { gutor 1 } +gutorPDW OBJECT IDENTIFIER ::= { gutor 2 } +gutorWEW OBJECT IDENTIFIER ::= { gutor 3 } +gutorWDW OBJECT IDENTIFIER ::= { gutor 4 } +gutorSDC OBJECT IDENTIFIER ::= { gutor 5 } + +upsIdent OBJECT IDENTIFIER ::= { ups 1 } +upsBattery OBJECT IDENTIFIER ::= { ups 2 } +upsInput OBJECT IDENTIFIER ::= { ups 3 } +upsOutput OBJECT IDENTIFIER ::= { ups 4 } +upsConfig OBJECT IDENTIFIER ::= { ups 5 } +upsControl OBJECT IDENTIFIER ::= { ups 6 } +upsTest OBJECT IDENTIFIER ::= { ups 7 } +upsComm OBJECT IDENTIFIER ::= { ups 8 } +upsPhase OBJECT IDENTIFIER ::= { ups 9 } +upsSyncCtrlGroup OBJECT IDENTIFIER ::= { ups 10 } +upsState OBJECT IDENTIFIER ::= { ups 11 } +upsOutletGroups OBJECT IDENTIFIER ::= { ups 12 } +upsDiagnostics OBJECT IDENTIFIER ::= { ups 13 } +upsParallelSystem OBJECT IDENTIFIER ::= { ups 14 } +upsPhysicalLayout OBJECT IDENTIFIER ::= { ups 15 } +upsIntegratedATS OBJECT IDENTIFIER ::= { ups 16 } + +upsBasicIdent OBJECT IDENTIFIER ::= { upsIdent 1 } +upsAdvIdent OBJECT IDENTIFIER ::= { upsIdent 2 } + +upsBasicBattery OBJECT IDENTIFIER ::= { upsBattery 1 } +upsAdvBattery OBJECT IDENTIFIER ::= { upsBattery 2 } +upsHighPrecBattery OBJECT IDENTIFIER ::= { upsBattery 3 } + +upsBasicInput OBJECT IDENTIFIER ::= { upsInput 1 } +upsAdvInput OBJECT IDENTIFIER ::= { upsInput 2 } +upsHighPrecInput OBJECT IDENTIFIER ::= { upsInput 3 } + +upsBasicOutput OBJECT IDENTIFIER ::= { upsOutput 1 } +upsAdvOutput OBJECT IDENTIFIER ::= { upsOutput 2 } +upsHighPrecOutput OBJECT IDENTIFIER ::= { upsOutput 3 } + +upsBasicConfig OBJECT IDENTIFIER ::= { upsConfig 1 } +upsAdvConfig OBJECT IDENTIFIER ::= { upsConfig 2 } + + +upsBasicControl OBJECT IDENTIFIER ::= { upsControl 1 } +upsAdvControl OBJECT IDENTIFIER ::= { upsControl 2 } + +upsBasicTest OBJECT IDENTIFIER ::= { upsTest 1 } +upsAdvTest OBJECT IDENTIFIER ::= { upsTest 2 } + +upsPhaseResetValues OBJECT IDENTIFIER ::= { upsPhase 1 } +upsPhaseInput OBJECT IDENTIFIER ::= { upsPhase 2 } +upsPhaseOutput OBJECT IDENTIFIER ::= { upsPhase 3 } + +upsSyncCtrlGroupConfig OBJECT IDENTIFIER ::= { upsSyncCtrlGroup 1 } +upsSyncCtrlGroupStatus OBJECT IDENTIFIER ::= { upsSyncCtrlGroup 2 } + +upsBasicState OBJECT IDENTIFIER ::= { upsState 1 } +upsAdvState OBJECT IDENTIFIER ::= { upsState 2 } + +upsOutletGroupStatus OBJECT IDENTIFIER ::= { upsOutletGroups 1 } +upsOutletGroupConfig OBJECT IDENTIFIER ::= { upsOutletGroups 2 } +upsOutletGroupControl OBJECT IDENTIFIER ::= { upsOutletGroups 3 } + +upsDiagnosticIM OBJECT IDENTIFIER ::= { upsDiagnostics 1 } +upsDiagnosticPowerModules OBJECT IDENTIFIER ::= { upsDiagnostics 2 } +upsDiagnosticBatteries OBJECT IDENTIFIER ::= { upsDiagnostics 3 } +upsDiagnosticSubsystem OBJECT IDENTIFIER ::= { upsDiagnostics 4 } +upsDiagnosticExternalDevices OBJECT IDENTIFIER ::= { upsDiagnostics 5 } +upsDiagnosticComBus OBJECT IDENTIFIER ::= { upsDiagnostics 6 } + +upsDiagSwitchGear OBJECT IDENTIFIER ::= { upsDiagnosticExternalDevices 1 } +upsDiagMCCBBox OBJECT IDENTIFIER ::= { upsDiagnosticExternalDevices 2 } +upsDiagTransformer OBJECT IDENTIFIER ::= { upsDiagnosticExternalDevices 3 } + +upsDiagFlyWheel OBJECT IDENTIFIER ::= { upsDiagnosticExternalDevices 4 } + + +mUpsEnviron OBJECT IDENTIFIER ::= { measureUps 1 } +mUpsContact OBJECT IDENTIFIER ::= { measureUps 2 } + +serialPort OBJECT IDENTIFIER ::= { miniSNMPadapter 1} + +serialPort1 OBJECT IDENTIFIER ::= { serialPort 1} +serialPort2 OBJECT IDENTIFIER ::= { serialPort 2} + +serialPort2Config OBJECT IDENTIFIER ::= { serialPort2 1} +serialPort2Control OBJECT IDENTIFIER ::= { serialPort2 2} + +sPDUIdent OBJECT IDENTIFIER ::= { masterswitch 1 } +sPDUMasterControl OBJECT IDENTIFIER ::= { masterswitch 2 } +sPDUMasterConfig OBJECT IDENTIFIER ::= { masterswitch 3 } +sPDUOutletControl OBJECT IDENTIFIER ::= { masterswitch 4 } +sPDUOutletConfig OBJECT IDENTIFIER ::= { masterswitch 5 } + +sPDUIdentVM OBJECT IDENTIFIER ::= { masterswitchVM 1 } +sPDUMasterControlVM OBJECT IDENTIFIER ::= { masterswitchVM 2 } +sPDUMasterConfigVM OBJECT IDENTIFIER ::= { masterswitchVM 3 } +sPDUMasterStatusVM OBJECT IDENTIFIER ::= { masterswitchVM 4 } +sPDUOutletControlVM OBJECT IDENTIFIER ::= { masterswitchVM 5 } +sPDUOutletConfigVM OBJECT IDENTIFIER ::= { masterswitchVM 6 } +sPDUOutletStatusVM OBJECT IDENTIFIER ::= { masterswitchVM 7 } + +sPDUIdentMSP OBJECT IDENTIFIER ::= { masterswitchMSP 1 } +sPDUMasterControlMSP OBJECT IDENTIFIER ::= { masterswitchMSP 2 } +sPDUMasterConfigMSP OBJECT IDENTIFIER ::= { masterswitchMSP 3 } +sPDUMasterStatusMSP OBJECT IDENTIFIER ::= { masterswitchMSP 4 } +sPDUOutletControlMSP OBJECT IDENTIFIER ::= { masterswitchMSP 5 } +sPDUOutletConfigMSP OBJECT IDENTIFIER ::= { masterswitchMSP 6 } +sPDUOutletStatusMSP OBJECT IDENTIFIER ::= { masterswitchMSP 7 } + +sPDUOutletConfigMSPall OBJECT IDENTIFIER ::= { sPDUOutletConfigMSP 1 } +sPDUOutletConfigMSPgs OBJECT IDENTIFIER ::= { sPDUOutletConfigMSP 2 } +sPDUOutletConfigMSPannun OBJECT IDENTIFIER ::= { sPDUOutletConfigMSP 3 } +sPDUOutletConfigMSPmups OBJECT IDENTIFIER ::= { sPDUOutletConfigMSP 4 } + +rPDUIdent OBJECT IDENTIFIER ::= { rPDU 1 } +rPDULoad OBJECT IDENTIFIER ::= { rPDU 2 } +rPDUOutlet OBJECT IDENTIFIER ::= { rPDU 3 } +rPDUPowerSupply OBJECT IDENTIFIER ::= { rPDU 4 } +rPDUStatus OBJECT IDENTIFIER ::= { rPDU 5 } + +rPDULoadDevice OBJECT IDENTIFIER ::= { rPDULoad 1 } +rPDULoadPhaseConfig OBJECT IDENTIFIER ::= { rPDULoad 2 } +rPDULoadStatus OBJECT IDENTIFIER ::= { rPDULoad 3 } +rPDULoadBankConfig OBJECT IDENTIFIER ::= { rPDULoad 4 } + +rPDUOutletDevice OBJECT IDENTIFIER ::= { rPDUOutlet 1 } +rPDUOutletPhase OBJECT IDENTIFIER ::= { rPDUOutlet 2 } +rPDUOutletControl OBJECT IDENTIFIER ::= { rPDUOutlet 3 } +rPDUOutletConfig OBJECT IDENTIFIER ::= { rPDUOutlet 4 } +rPDUOutletStatus OBJECT IDENTIFIER ::= { rPDUOutlet 5 } +rPDUOutletBank OBJECT IDENTIFIER ::= { rPDUOutlet 6 } + +rPDUPowerSupplyDevice OBJECT IDENTIFIER ::= { rPDUPowerSupply 1 } + +dm3Ident OBJECT IDENTIFIER ::= { dcDM3 1 } +dm3Config OBJECT IDENTIFIER ::= { dcDM3 2 } +dm3Status OBJECT IDENTIFIER ::= { dcDM3 3 } + +dm3IdentSystem OBJECT IDENTIFIER ::= { dm3Ident 1} + +dm3ConfigSystem OBJECT IDENTIFIER ::= { dm3Config 1 } +dm3ConfigLVD OBJECT IDENTIFIER ::= { dm3Config 2 } +dm3ConfigBattery OBJECT IDENTIFIER ::= { dm3Config 3 } +dm3ConfigPowerModules OBJECT IDENTIFIER ::= { dm3Config 4 } +dm3ConfigRelays OBJECT IDENTIFIER ::= { dm3Config 5 } +dm3ConfigDistribution OBJECT IDENTIFIER ::= { dm3Config 6 } + +dm3ConfigRectifier OBJECT IDENTIFIER ::= { dm3ConfigPowerModules 1 } +dm3ConfigConverter OBJECT IDENTIFIER ::= { dm3ConfigPowerModules 2 } + +dm3ConfigRectThresh OBJECT IDENTIFIER ::= { dm3ConfigRectifier 1 } +dm3ConfigRectAlarms OBJECT IDENTIFIER ::= { dm3ConfigRectifier 2 } + +dm3ConfigConvThresh OBJECT IDENTIFIER ::= { dm3ConfigConverter 1 } +dm3ConfigConvAlarms OBJECT IDENTIFIER ::= { dm3ConfigConverter 2 } + +dm3ConfigOutputRelays OBJECT IDENTIFIER ::= { dm3ConfigRelays 1 } +dm3ConfigInputRelays OBJECT IDENTIFIER ::= { dm3ConfigRelays 2 } + +dm3ConfigBreakers OBJECT IDENTIFIER ::= { dm3ConfigDistribution 1 } +dm3ConfigFuses OBJECT IDENTIFIER ::= { dm3ConfigDistribution 2 } + +dm3StatusSystem OBJECT IDENTIFIER ::= { dm3Status 1 } +dm3StatusAlarms OBJECT IDENTIFIER ::= { dm3Status 2 } +dm3StatusBattery OBJECT IDENTIFIER ::= { dm3Status 3 } +dm3StatusOEM OBJECT IDENTIFIER ::= { dm3Status 4 } +dm3StatusLVD OBJECT IDENTIFIER ::= { dm3Status 5 } +dm3StatusPowerModules OBJECT IDENTIFIER ::= { dm3Status 6 } +dm3StatusRelays OBJECT IDENTIFIER ::= { dm3Status 7 } +dm3StatusDistribution OBJECT IDENTIFIER ::= { dm3Status 8 } + +dm3StatusRectifier OBJECT IDENTIFIER ::= { dm3StatusPowerModules 1 } +dm3StatusConverter OBJECT IDENTIFIER ::= { dm3StatusPowerModules 2 } + +dm3StatusOutputRelays OBJECT IDENTIFIER ::= { dm3StatusRelays 1 } +dm3StatusInputRelays OBJECT IDENTIFIER ::= { dm3StatusRelays 2 } + +dm3StatusBreakers OBJECT IDENTIFIER ::= { dm3StatusDistribution 1 } +dm3StatusFuses OBJECT IDENTIFIER ::= { dm3StatusDistribution 2 } + +atsIdent OBJECT IDENTIFIER ::= { automaticTransferSwitch 1 } +atsCalibration OBJECT IDENTIFIER ::= { automaticTransferSwitch 2 } +atsControl OBJECT IDENTIFIER ::= { automaticTransferSwitch 3 } +atsConfig OBJECT IDENTIFIER ::= { automaticTransferSwitch 4 } +atsStatus OBJECT IDENTIFIER ::= { automaticTransferSwitch 5 } + +atsCalibrationInput OBJECT IDENTIFIER ::= { atsCalibration 1 } +atsCalibrationPowerSupply OBJECT IDENTIFIER ::= { atsCalibration 2 } +atsCalibrationOutput OBJECT IDENTIFIER ::= { atsCalibration 3 } + +atsStatusDeviceStatus OBJECT IDENTIFIER ::= { atsStatus 1 } +atsStatusResetValues OBJECT IDENTIFIER ::= { atsStatus 2 } +atsStatusInput OBJECT IDENTIFIER ::= { atsStatus 3 } +atsStatusOutput OBJECT IDENTIFIER ::= { atsStatus 4 } + +dcmim2Ident OBJECT IDENTIFIER ::= { dc2 1 } +dcmim2Control OBJECT IDENTIFIER ::= { dc2 2 } +dcmim2Config OBJECT IDENTIFIER ::= { dc2 3 } +dcmim2Status OBJECT IDENTIFIER ::= { dc2 4 } + +dcmim2IdentSystem OBJECT IDENTIFIER ::= { dcmim2Ident 1 } + +dcmim2ControlSystem OBJECT IDENTIFIER ::= { dcmim2Control 1 } + +dcmim2ConfigSystem OBJECT IDENTIFIER ::= { dcmim2Config 1 } +dcmim2ConfigBattery OBJECT IDENTIFIER ::= { dcmim2Config 2 } +dcmim2ConfigLVD OBJECT IDENTIFIER ::= { dcmim2Config 3 } + +dcmim2StatusSystem OBJECT IDENTIFIER ::= { dcmim2Status 1 } +dcmim2StatusRectifier OBJECT IDENTIFIER ::= { dcmim2Status 2 } +dcmim2StatusBattery OBJECT IDENTIFIER ::= { dcmim2Status 3 } +dcmim2StatusLVD OBJECT IDENTIFIER ::= { dcmim2Status 4 } +dcmim2StatusAlarms OBJECT IDENTIFIER ::= { dcmim2Status 5 } + +external OBJECT IDENTIFIER ::= { environmentalMonitor 1 } +integrated OBJECT IDENTIFIER ::= { environmentalMonitor 2 } +envMgtSystem OBJECT IDENTIFIER ::= { environmentalMonitor 3 } +modEnvMgr OBJECT IDENTIFIER ::= { environmentalMonitor 4 } + +emIdent OBJECT IDENTIFIER ::= { external 1 } +emConfig OBJECT IDENTIFIER ::= { external 2 } +emStatus OBJECT IDENTIFIER ::= { external 3 } + +iemIdent OBJECT IDENTIFIER ::= { integrated 1 } +iemConfig OBJECT IDENTIFIER ::= { integrated 2 } +iemStatus OBJECT IDENTIFIER ::= { integrated 3 } + +emsIdent OBJECT IDENTIFIER ::= { envMgtSystem 1 } + +emsOutputRelayControl OBJECT IDENTIFIER ::= { envMgtSystem 2 } +emsOutletControl OBJECT IDENTIFIER ::= { envMgtSystem 3 } +emsSensorControl OBJECT IDENTIFIER ::= { envMgtSystem 4 } +emsAlarmDeviceControl OBJECT IDENTIFIER ::= { envMgtSystem 5 } + +emsConfig OBJECT IDENTIFIER ::= { envMgtSystem 6 } +emsProbeConfig OBJECT IDENTIFIER ::= { envMgtSystem 7 } +emsInputContactConfig OBJECT IDENTIFIER ::= { envMgtSystem 8 } +emsOutputRelayConfig OBJECT IDENTIFIER ::= { envMgtSystem 9 } +emsOutletConfig OBJECT IDENTIFIER ::= { envMgtSystem 10 } +emsSensorConfig OBJECT IDENTIFIER ::= { envMgtSystem 11 } + +emsStatus OBJECT IDENTIFIER ::= { envMgtSystem 12 } +emsProbeStatus OBJECT IDENTIFIER ::= { envMgtSystem 13 } +emsInputContactStatus OBJECT IDENTIFIER ::= { envMgtSystem 14 } +emsOutputRelayStatus OBJECT IDENTIFIER ::= { envMgtSystem 15 } +emsOutletStatus OBJECT IDENTIFIER ::= { envMgtSystem 16 } +emsAlarmDeviceStatus OBJECT IDENTIFIER ::= { envMgtSystem 17 } +emsSensorStatus OBJECT IDENTIFIER ::= { envMgtSystem 18 } + +memModules OBJECT IDENTIFIER ::= { modEnvMgr 1 } +memSensors OBJECT IDENTIFIER ::= { modEnvMgr 2 } +memInputs OBJECT IDENTIFIER ::= { modEnvMgr 3 } +memOutputs OBJECT IDENTIFIER ::= { modEnvMgr 4 } +memOutlets OBJECT IDENTIFIER ::= { modEnvMgr 5 } +memBeacons OBJECT IDENTIFIER ::= { modEnvMgr 6 } + +nlIdent OBJECT IDENTIFIER ::= { netlock 1 } +nlStatus OBJECT IDENTIFIER ::= { netlock 2 } + +airFM OBJECT IDENTIFIER ::= { airConditioners 1 } +airFMIdent OBJECT IDENTIFIER ::= { airFM 1 } +airFMStatus OBJECT IDENTIFIER ::= { airFM 2 } +airFMGroup OBJECT IDENTIFIER ::= { airFM 3 } +airFMSystem OBJECT IDENTIFIER ::= { airFM 4 } +airFMModule OBJECT IDENTIFIER ::= { airFM 5 } +airFMAlarms OBJECT IDENTIFIER ::= { airFM 6 } + +airFMGroupSysRoles OBJECT IDENTIFIER ::= { airFMGroup 4 } +airFMGroupCfg OBJECT IDENTIFIER ::= { airFMGroup 5 } +airFMGroupLoadShare OBJECT IDENTIFIER ::= { airFMGroup 6 } +airFMGroupFailover OBJECT IDENTIFIER ::= { airFMGroup 7 } + +airFMGroupFailoverSys OBJECT IDENTIFIER ::= { airFMGroupFailover 1 } +airFMGroupFailoverMod OBJECT IDENTIFIER ::= { airFMGroupFailover 2 } + +airFMSysStatus OBJECT IDENTIFIER ::= { airFMSystem 1 } +airFMSysDemands OBJECT IDENTIFIER ::= { airFMSystem 2 } +airFMSysSetup OBJECT IDENTIFIER ::= { airFMSystem 3 } +airFMSysConfig OBJECT IDENTIFIER ::= { airFMSystem 4 } +airFMSysCooling OBJECT IDENTIFIER ::= { airFMSystem 5 } +airFMSysHumidify OBJECT IDENTIFIER ::= { airFMSystem 6 } +airFMSysDehumidify OBJECT IDENTIFIER ::= { airFMSystem 7 } +airFMSysReheat OBJECT IDENTIFIER ::= { airFMSystem 8 } +airFMSysThresholds OBJECT IDENTIFIER ::= { airFMSystem 9 } +airFMSysInputs OBJECT IDENTIFIER ::= { airFMSystem 10 } +airFMSysOutputs OBJECT IDENTIFIER ::= { airFMSystem 11 } +airFMSysAlarmMap OBJECT IDENTIFIER ::= { airFMSystem 12 } + +airFMSysAlarmMapSys OBJECT IDENTIFIER ::= { airFMSysAlarmMap 1 } +airFMSysAlarmMapMainMod OBJECT IDENTIFIER ::= { airFMSysAlarmMap 2 } +airFMSysAlarmMapExpMod1 OBJECT IDENTIFIER ::= { airFMSysAlarmMap 3 } +airFMSysAlarmMapExpMod2 OBJECT IDENTIFIER ::= { airFMSysAlarmMap 4 } +airFMSysAlarmMapInput OBJECT IDENTIFIER ::= { airFMSysAlarmMap 5 } +airFMSysAlarmMapOutput OBJECT IDENTIFIER ::= { airFMSysAlarmMap 6 } + +airFMModIdent OBJECT IDENTIFIER ::= { airFMModule 1 } +airFMModStatus OBJECT IDENTIFIER ::= { airFMModule 2 } +airFMModProperties OBJECT IDENTIFIER ::= { airFMModule 3 } +airFMModCooling OBJECT IDENTIFIER ::= { airFMModule 4 } +airFMModHumidity OBJECT IDENTIFIER ::= { airFMModule 5 } +airFMModBlower1 OBJECT IDENTIFIER ::= { airFMModule 6 } +airFMModBlower2 OBJECT IDENTIFIER ::= { airFMModule 7 } +airFMModRunHours OBJECT IDENTIFIER ::= { airFMModule 8 } +airFMModServIntervals OBJECT IDENTIFIER ::= { airFMModule 9 } +airFMModServIntResets OBJECT IDENTIFIER ::= { airFMModule 10 } + + +airPA OBJECT IDENTIFIER ::= { airConditioners 2 } +airPAIdent OBJECT IDENTIFIER ::= { airPA 1 } +airPAStatus OBJECT IDENTIFIER ::= { airPA 2 } + +airIR OBJECT IDENTIFIER ::= { airConditioners 3 } +airIRAlarms OBJECT IDENTIFIER ::= { airIR 1 } +airIRRC OBJECT IDENTIFIER ::= { airIR 2 } +airIRRP OBJECT IDENTIFIER ::= { airIR 3 } +airIRSC OBJECT IDENTIFIER ::= { airIR 4 } + +airIRRCGroup OBJECT IDENTIFIER ::= { airIRRC 1 } +airIRRCUnit OBJECT IDENTIFIER ::= { airIRRC 2 } + +airIRRCGroupStatus OBJECT IDENTIFIER ::= { airIRRCGroup 1 } +airIRRCGroupSetpoints OBJECT IDENTIFIER ::= { airIRRCGroup 2 } +airIRRCGroupConfig OBJECT IDENTIFIER ::= { airIRRCGroup 3 } + +airIRRCUnitIdent OBJECT IDENTIFIER ::= { airIRRCUnit 1 } +airIRRCUnitStatus OBJECT IDENTIFIER ::= { airIRRCUnit 2 } +airIRRCUnitRunHours OBJECT IDENTIFIER ::= { airIRRCUnit 3 } +airIRRCUnitServiceIntervals OBJECT IDENTIFIER ::= { airIRRCUnit 4 } +airIRRCUnitThresholds OBJECT IDENTIFIER ::= { airIRRCUnit 5 } +airIRRCUnitConfig OBJECT IDENTIFIER ::= { airIRRCUnit 6 } + +-- Series 100 DX Air Conditioners +airIRRP100 OBJECT IDENTIFIER ::= { airIRRP 1 } +-- Series 500 CW Air Conditioners +airIRRP500 OBJECT IDENTIFIER ::= { airIRRP 2 } + +airIRRP100Group OBJECT IDENTIFIER ::= { airIRRP100 1 } +airIRRP100Unit OBJECT IDENTIFIER ::= { airIRRP100 2 } + +airIRRP100GroupStatus OBJECT IDENTIFIER ::= { airIRRP100Group 1 } +airIRRP100GroupSetpoints OBJECT IDENTIFIER ::= { airIRRP100Group 2 } +airIRRP100GroupConfig OBJECT IDENTIFIER ::= { airIRRP100Group 3 } + +airIRRP100UnitIdent OBJECT IDENTIFIER ::= { airIRRP100Unit 1 } +airIRRP100UnitStatus OBJECT IDENTIFIER ::= { airIRRP100Unit 2 } +airIRRP100UnitRunHours OBJECT IDENTIFIER ::= { airIRRP100Unit 3 } +airIRRP100UnitServiceIntervals OBJECT IDENTIFIER ::= { airIRRP100Unit 4 } +airIRRP100UnitThresholds OBJECT IDENTIFIER ::= { airIRRP100Unit 5 } +airIRRP100UnitConfig OBJECT IDENTIFIER ::= { airIRRP100Unit 6 } + +airIRRP500Group OBJECT IDENTIFIER ::= { airIRRP500 1 } +airIRRP500Unit OBJECT IDENTIFIER ::= { airIRRP500 2 } + +airIRRP500GroupStatus OBJECT IDENTIFIER ::= { airIRRP500Group 1 } +airIRRP500GroupSetpoints OBJECT IDENTIFIER ::= { airIRRP500Group 2 } +airIRRP500GroupConfig OBJECT IDENTIFIER ::= { airIRRP500Group 3 } + +airIRRP500UnitIdent OBJECT IDENTIFIER ::= { airIRRP500Unit 1 } +airIRRP500UnitStatus OBJECT IDENTIFIER ::= { airIRRP500Unit 2 } +airIRRP500UnitRunHours OBJECT IDENTIFIER ::= { airIRRP500Unit 3 } +airIRRP500UnitServiceIntervals OBJECT IDENTIFIER ::= { airIRRP500Unit 4 } +airIRRP500UnitThresholds OBJECT IDENTIFIER ::= { airIRRP500Unit 5 } +airIRRP500UnitConfig OBJECT IDENTIFIER ::= { airIRRP500Unit 6 } + + +airIRSCUnit OBJECT IDENTIFIER ::= { airIRSC 1 } + +airIRSCUnitIdent OBJECT IDENTIFIER ::= { airIRSCUnit 1 } +airIRSCUnitStatus OBJECT IDENTIFIER ::= { airIRSCUnit 2 } +airIRSCUnitRunHours OBJECT IDENTIFIER ::= { airIRSCUnit 3 } +airIRSCUnitServiceIntervals OBJECT IDENTIFIER ::= { airIRSCUnit 4 } +airIRSCUnitThresholds OBJECT IDENTIFIER ::= { airIRSCUnit 5 } +airIRSCUnitSetpoints OBJECT IDENTIFIER ::= { airIRSCUnit 6 } +airIRSCUnitConfig OBJECT IDENTIFIER ::= { airIRSCUnit 7 } + +airIRSCGroup OBJECT IDENTIFIER ::= { airIRSC 2 } + +airIRSCGroupStatus OBJECT IDENTIFIER ::= { airIRSCGroup 1 } +airIRSCGroupSetpoints OBJECT IDENTIFIER ::= { airIRSCGroup 2 } +airIRSCGroupConfig OBJECT IDENTIFIER ::= { airIRSCGroup 3 } + + +airIRGen2 OBJECT IDENTIFIER ::= { airConditioners 4 } + +airIRG2Ident OBJECT IDENTIFIER ::= { airIRGen2 1 } +airIRG2Group OBJECT IDENTIFIER ::= { airIRGen2 2 } +airIRG2Alarms OBJECT IDENTIFIER ::= { airIRGen2 3 } +airIRG2RC OBJECT IDENTIFIER ::= { airIRGen2 4 } +airIRG2RD OBJECT IDENTIFIER ::= { airIRGen2 5 } +airIRG2SC OBJECT IDENTIFIER ::= { airIRGen2 6 } +airIRG2RA OBJECT IDENTIFIER ::= { airIRGen2 7 } + +-- airIR Gen2 Group data +airIRG2GroupStatus OBJECT IDENTIFIER ::= { airIRG2Group 1 } +airIRG2GroupSetpoints OBJECT IDENTIFIER ::= { airIRG2Group 2 } +airIRG2GroupConfig OBJECT IDENTIFIER ::= { airIRG2Group 3 } + +-- airIR Gen2 RD Unit data +airIRG2RDType1 OBJECT IDENTIFIER ::= { airIRG2RD 1 } +airIRG2RDType2 OBJECT IDENTIFIER ::= { airIRG2RD 2 } +airIRG2RDT2Status OBJECT IDENTIFIER ::= { airIRG2RDType2 1 } +airIRG2RDT2RunHours OBJECT IDENTIFIER ::= { airIRG2RDType2 2 } +airIRG2RDT2ServiceIntervals OBJECT IDENTIFIER ::= { airIRG2RDType2 3 } +airIRG2RDT2Thresholds OBJECT IDENTIFIER ::= { airIRG2RDType2 4 } +airIRG2RDT2Setpoints OBJECT IDENTIFIER ::= { airIRG2RDType2 5 } +airIRG2RDT2Config OBJECT IDENTIFIER ::= { airIRG2RDType2 6 } + +airInRoom OBJECT IDENTIFIER ::= { airConditioners 5 } + +airIRmIdent OBJECT IDENTIFIER ::= { airInRoom 1 } +airIRmAlarms OBJECT IDENTIFIER ::= { airInRoom 2 } +airIRmPerimeter OBJECT IDENTIFIER ::= { airInRoom 3 } + +airIRmPmCommon1 OBJECT IDENTIFIER ::= { airIRmPerimeter 2 } +airIRmPmCommon2 OBJECT IDENTIFIER ::= { airIRmPerimeter 3 } +airIRmPmCommon3 OBJECT IDENTIFIER ::= { airIRmPerimeter 4 } +airIRmPmCommon4 OBJECT IDENTIFIER ::= { airIRmPerimeter 5 } +airIRmPmCommon5 OBJECT IDENTIFIER ::= { airIRmPerimeter 6 } +airIRmPmCompressor1 OBJECT IDENTIFIER ::= { airIRmPerimeter 7 } +airIRmPmCompressor2 OBJECT IDENTIFIER ::= { airIRmPerimeter 8 } +airIRmPmSuctionValve1 OBJECT IDENTIFIER ::= { airIRmPerimeter 9 } +airIRmPmSuctionValve2 OBJECT IDENTIFIER ::= { airIRmPerimeter 10 } +airIRmPmEheating1 OBJECT IDENTIFIER ::= { airIRmPerimeter 11 } +airIRmPmEheating2 OBJECT IDENTIFIER ::= { airIRmPerimeter 12 } +airIRmPmEheating3 OBJECT IDENTIFIER ::= { airIRmPerimeter 13 } +airIRmPmEheating4 OBJECT IDENTIFIER ::= { airIRmPerimeter 14 } +airIRmPmGECWvalve OBJECT IDENTIFIER ::= { airIRmPerimeter 15 } +airIRmPmGvalve OBJECT IDENTIFIER ::= { airIRmPerimeter 16 } +airIRmPmDrycooler1 OBJECT IDENTIFIER ::= { airIRmPerimeter 17 } +airIRmPmDrycooler2 OBJECT IDENTIFIER ::= { airIRmPerimeter 18 } +airIRmPmDrycooler3 OBJECT IDENTIFIER ::= { airIRmPerimeter 19 } +airIRmPmDrycooler4 OBJECT IDENTIFIER ::= { airIRmPerimeter 20 } +airIRmPmPump1 OBJECT IDENTIFIER ::= { airIRmPerimeter 21 } +airIRmPmPump2 OBJECT IDENTIFIER ::= { airIRmPerimeter 22 } +airIRmPmPump3 OBJECT IDENTIFIER ::= { airIRmPerimeter 23 } +airIRmPmPump4 OBJECT IDENTIFIER ::= { airIRmPerimeter 24 } +airIRmPmHotgasHeating OBJECT IDENTIFIER ::= { airIRmPerimeter 25 } +airIRmPmPWWHeating OBJECT IDENTIFIER ::= { airIRmPerimeter 26 } +airIRmPmHumidifier1 OBJECT IDENTIFIER ::= { airIRmPerimeter 27 } +airIRmPmHumidifier2 OBJECT IDENTIFIER ::= { airIRmPerimeter 28 } +-- Skipping 29 and 30. +airIRmPmDehumidification OBJECT IDENTIFIER ::= { airIRmPerimeter 31 } +airIRmPmFan1 OBJECT IDENTIFIER ::= { airIRmPerimeter 32 } +airIRmPmFan2 OBJECT IDENTIFIER ::= { airIRmPerimeter 33 } +airIRmPmFan3 OBJECT IDENTIFIER ::= { airIRmPerimeter 34 } +airIRmPmLouver1 OBJECT IDENTIFIER ::= { airIRmPerimeter 35 } +airIRmPmLouver2 OBJECT IDENTIFIER ::= { airIRmPerimeter 36 } +airIRmPmLouver3 OBJECT IDENTIFIER ::= { airIRmPerimeter 37 } +airIRmPmAuxAlarm1 OBJECT IDENTIFIER ::= { airIRmPerimeter 38 } +airIRmPmAuxAlarm2 OBJECT IDENTIFIER ::= { airIRmPerimeter 39 } +airIRmPmAuxAlarm3 OBJECT IDENTIFIER ::= { airIRmPerimeter 40 } +airIRmPmAuxAlarm4 OBJECT IDENTIFIER ::= { airIRmPerimeter 41 } +airIRmPmAuxAlarm5 OBJECT IDENTIFIER ::= { airIRmPerimeter 42 } +airIRmPmAlarmBits OBJECT IDENTIFIER ::= { airIRmPerimeter 43 } +airIRmPmMyZone OBJECT IDENTIFIER ::= { airIRmPerimeter 44 } +airIRmPmGlobalZoneData OBJECT IDENTIFIER ::= { airIRmPerimeter 45 } + +airIRGen3 OBJECT IDENTIFIER ::= { airConditioners 6 } + +airIRG3Ident OBJECT IDENTIFIER ::= { airIRGen3 1 } +airIRG3Group OBJECT IDENTIFIER ::= { airIRGen3 2 } +airIRG3Alarms OBJECT IDENTIFIER ::= { airIRGen3 3 } +airIRG3RDU OBJECT IDENTIFIER ::= { airIRGen3 4 } +airIRG3CM OBJECT IDENTIFIER ::= { airIRGen3 5 } + + +rARUIdent OBJECT IDENTIFIER ::= { rARU 1 } +rARUConfig OBJECT IDENTIFIER ::= { rARU 2 } +rARUStatus OBJECT IDENTIFIER ::= { rARU 3 } +rARUFanStatus OBJECT IDENTIFIER ::= { rARU 4 } +rARUPower OBJECT IDENTIFIER ::= { rARU 5 } +rARUSensors OBJECT IDENTIFIER ::= { rARU 6 } + + +accessPX OBJECT IDENTIFIER ::= { accessControl 1 } + +accessPXIdent OBJECT IDENTIFIER ::= { accessPX 1 } +accessPXConfig OBJECT IDENTIFIER ::= { accessPX 2 } +accessPXConfigFront OBJECT IDENTIFIER ::= { accessPX 3 } +accessPXStatusFront OBJECT IDENTIFIER ::= { accessPX 4 } +accessPXConfigRear OBJECT IDENTIFIER ::= { accessPX 5 } +accessPXStatusRear OBJECT IDENTIFIER ::= { accessPX 6 } +accessPXConfigBeacon OBJECT IDENTIFIER ::= { accessPX 7 } +accessPXStatusBeacon OBJECT IDENTIFIER ::= { accessPX 8 } + +apcLocalDisplayIdent OBJECT IDENTIFIER ::= { apcLocalDisplay 1 } +apcLocalDisplayConfig OBJECT IDENTIFIER ::= { apcLocalDisplay 2 } + +accPX OBJECT IDENTIFIER ::= { accControl 1 } + +isxModularPduIdent OBJECT IDENTIFIER ::= { isxModularPdu 1 } +isxModularPduDevice OBJECT IDENTIFIER ::= { isxModularPdu 2 } +isxModularPduStatus OBJECT IDENTIFIER ::= { isxModularPdu 3 } + +symmetraPx48kVA OBJECT IDENTIFIER ::= { symmetraPX 1 } +symmetraPx160kVA OBJECT IDENTIFIER ::= { symmetraPX 2 } +symmetraPx250kVA OBJECT IDENTIFIER ::= { symmetraPX 3 } +symmetraPx500kVA OBJECT IDENTIFIER ::= { symmetraPX 4 } +symmetraPx100kVA OBJECT IDENTIFIER ::= { symmetraPX 5 } +symmetraPxDisplay OBJECT IDENTIFIER ::= { symmetraPX 6 } + +isx24ModuleHalfRackPdu OBJECT IDENTIFIER ::= { isxModDistribution 1 } +isx6ModuleRackPdu OBJECT IDENTIFIER ::= { isxModDistribution 2 } + +isxModularDistInfo OBJECT IDENTIFIER ::= { isxModularDistribution 1 } +isxModularDistModules OBJECT IDENTIFIER ::= { isxModularDistribution 2 } +isxModularDistSubFeeds OBJECT IDENTIFIER ::= { isxModularDistribution 3 } +isxModularDistTotals OBJECT IDENTIFIER ::= { isxModularDistribution 4 } + +isxModularDistSysVoltage OBJECT IDENTIFIER ::= { isxModularDistTotals 1 } +isxModularDistSysCurrent OBJECT IDENTIFIER ::= { isxModularDistTotals 2 } +isxModularDistSysPower OBJECT IDENTIFIER ::= { isxModularDistTotals 3 } + +isxcBasic OBJECT IDENTIFIER ::= { isxServers 1 } +isxcStandard OBJECT IDENTIFIER ::= { isxServers 2 } +isxcEnterprise OBJECT IDENTIFIER ::= { isxServers 3 } +isxcVirtual OBJECT IDENTIFIER ::= { isxServers 4 } + +uioSensor OBJECT IDENTIFIER ::= { universalInputOutput 1 } +uioInputContact OBJECT IDENTIFIER ::= { universalInputOutput 2 } +uioOutputRelay OBJECT IDENTIFIER ::= { universalInputOutput 3 } + + +-- object types + +-- the products group +-- the experimental group + + + +-- the apcmgmt group +-- the mconfig group + +mconfigNumTrapReceivers OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of managers to send traps to." + ::= { mconfig 1 } + +mconfigTrapReceiverTable OBJECT-TYPE + SYNTAX SEQUENCE OF MconfigTrapReceiverEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of managers to send traps to. The number of + entries is given by the value of mconfigNumTrapReceivers." + ::= { mconfig 2 } + +mconfigTrapReceiverEntry OBJECT-TYPE + SYNTAX MconfigTrapReceiverEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The managers to send traps to." + INDEX { trapIndex} + ::= { mconfigTrapReceiverTable 1 } + +MconfigTrapReceiverEntry ::= + SEQUENCE { + trapIndex + INTEGER, + receiverAddr + IpAddress, + communityString + DisplayString, + severity + INTEGER, + acceptThisReceiver + INTEGER, + receiveTrapType + INTEGER + } + +trapIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to a trap receiver entry." + ::= { mconfigTrapReceiverEntry 1 } + +receiverAddr OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The IP address of the manager to send a trap to." + ::= { mconfigTrapReceiverEntry 2 } + +communityString OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The community name to use in the trap when + sent to the manager." + ::= { mconfigTrapReceiverEntry 3 } + +severity OBJECT-TYPE + SYNTAX INTEGER { + information(1), + warning(2), + severe(3) + } + ACCESS read-only + STATUS obsolete + DESCRIPTION + "The severity threshold of traps to send to the manager. + traps are labeled in severity as informational(1), warning(2), + severe(3). Only traps of equal or greater severity than + this value are sent to the manager." + ::= { mconfigTrapReceiverEntry 4 } + +acceptThisReceiver OBJECT-TYPE + SYNTAX INTEGER { + yes (1), + no (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of yes(1) indicates that trap generation for this manager is enabled. + The value of no(2) indicates that trap generation for this manager is disabled" + ::= { mconfigTrapReceiverEntry 5 } + + +receiveTrapType OBJECT-TYPE + SYNTAX INTEGER { + powernet (1), + ietf (2), + both (3) + } + ACCESS read-only + STATUS obsolete + DESCRIPTION + "Type of trap." + ::= { mconfigTrapReceiverEntry 6 } + +mconfigBOOTPEnabled OBJECT-TYPE + SYNTAX INTEGER { + yes (1), + no (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of yes(1) indicates the PowerNet Adapter is configured to + obtain its IP configuration parameters from a BOOTP server. + + The value of no(2) indicates adapter will assume IP configuration parameters + values saved in adapter's eeprom, which was originally configured at local + console." + ::= { mconfig 3 } + +mconfigTFTPServerIP OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The IP address of TFTP server. If mconfigBOOTPEnabled is yes(1), then this IP address + is provided by BOOTP server and not allowed to be modified; otherwise, this IP address + can be modified. + + Before using TFTP to load new code image, the image file should be placed in proper + directory of the specified TFTP server. This OID is only supported by APC Network + Management Cards." + ::= { mconfig 4 } + +newCodeAuthentViaTFTP OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + validNewAgentCodeImage (2), + sameAgentCodeImage (3), + invalidAgentCodeImage (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Once mcontrolRestartAgent is set to loadAndExecuteNewAgent (3), PowerNet adapter will + start to load the remote image file, for authentication only, instead of saving the code + into flash memory. Only if a validNewAgentCodeImage (1) is found will the agent reboot + the PowerNet adapter and invoke the loader to load and save new code into the flash memory. + Otherwise, the current agent code will continue to run. + + This OID shows the result of the above authentication process. + validNewAgentCodeImage (1) means the code image on TFTP server + is a valid APC agent code and is different version from the current agent. + Once agent identifies this, loader will start to update flash memory with + the new agent code. + + sameAgentCodeImage (2) means the code image on TFTP server is exactly the + same as the currently running agent. Currently running agent will not invoke + loader to load the same again. + + invalidAgentCodeImage (3) means the code image on TFTP server is NOT a valid + APC agent code. Thus, current agent will not load it into the flash memory. + + The value of this OID will be associated with TRAP codeImageAuthentDone. + This OID is only supported by APC Network Management Cards." + + ::= { mconfig 5 } + +mconfigClockDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The current date in the mm/dd/yyyy format. Example: 01/01/2000." + ::= { mconfigClock 1 } + +mconfigClockTime OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The current time in the hh:mm:ss am/pm format. Example: 12:00:00 am." + ::= { mconfigClock 2 } + +mcontrolRestartAgent OBJECT-TYPE + SYNTAX INTEGER { + restartCurrentAgent (1), + continueCurrentAgent (2), + loadAndExecuteNewAgent (3), + restartWithoutAgent (4), + resetNetworkAndRestart (5), + resetNetworkLeaveModeAndRestart (6) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to restartCurrentAgent (1) will restart the same SNMP + agent code currently saved in flash memory. Setting this OID to + loadAndExecuteNewAgent (3) will enable adapter to load a new agent code + into the flash memory and start to execute this new agent code. + Bootp/tftp is the default protocol. loadAndExecuteNewAgent is only + supported by APC Network Management Cards. Setting + this OID to restartWithoutAgent (4) will restart the system and not + start the agent. The subsequent time the system restarts the agent will + also automatically restart. Setting this OID to + resetNetworkAndRestart (5) will set the Boot Mode, IP Address, Subnet + Mask, and Default Gateway to defaults, expire any existing DHCP lease + and then restart the system. Setting this OID to + resetNetworkLeaveModeAndRestart (6) will leave the Boot Mode at the + current setting, set the IP Address, Subnet Mask, and Default Gateway to + defaults, expire any existing DHCP lease and then restart the system." + + ::= { mcontrol 1 } + +-- The mtrapargs group +-- These OIDs allows APC traps to be sent with additional arguments +-- which may not be defined in the APC MIB. + +mtrapargsInteger OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an integer argument + that my not be defined in the APC MIB. + + A get of this OID will return 0." + ::= { mtrapargs 1 } + +mtrapargsIpAddress OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an IP address argument + that my not be defined in the APC MIB. + + A get of this OID will return 0.0.0.0." + ::= { mtrapargs 2 } + +mtrapargsString OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 3 } + +mtrapargsGauge OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with a Gauge argument + that my not be defined in the APC MIB. + + A get of this OID will return 0." + ::= { mtrapargs 4 } + +mtrapargsTimeTicks OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with a TimeTicks argument + that my not be defined in the APC MIB. + + A get of this OID will return 0." + ::= { mtrapargs 5 } + +mtrapargsInteger02 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an integer argument + that my not be defined in the APC MIB. + + A get of this OID will return 0." + ::= { mtrapargs 6 } + +mtrapargsInteger03 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an integer argument + that my not be defined in the APC MIB. + + A get of this OID will return 0." + ::= { mtrapargs 7 } + +mtrapargsIpAddress02 OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an IP address argument + that my not be defined in the APC MIB. + + A get of this OID will return 0.0.0.0." + ::= { mtrapargs 8 } + +mtrapargsIpAddress03 OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an IP address argument + that my not be defined in the APC MIB. + + A get of this OID will return 0.0.0.0." + ::= { mtrapargs 9 } + +mtrapargsString02 OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 10 } + +mtrapargsString03 OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 11 } + +mtrapargsGauge02 OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with a Gauge argument + that my not be defined in the APC MIB. + + A get of this OID will return 0." + ::= { mtrapargs 12 } + +mtrapargsGauge03 OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with a Gauge argument + that my not be defined in the APC MIB. + + A get of this OID will return 0." + ::= { mtrapargs 13 } + +mtrapargsTimeTicks02 OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with a TimeTicks argument + that my not be defined in the APC MIB. + + A get of this OID will return 0." + ::= { mtrapargs 14 } + +mtrapargsTimeTicks03 OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with a TimeTicks argument + that my not be defined in the APC MIB. + + A get of this OID will return 0." + ::= { mtrapargs 15 } + +mtrapargsString04 OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 16 } + +mtrapargsString05 OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 17 } + +mtrapargsInteger04 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an integer argument + that my not be defined in the APC MIB. + + A get of this OID will return 0." + ::= { mtrapargs 18 } + +mtrapargsInteger05 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an integer argument + that my not be defined in the APC MIB. + + A get of this OID will return 0." + ::= { mtrapargs 19 } + +mtrapargsString06 OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 20 } + +mtrapargsString07 OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 21 } + +mtrapargsString08 OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 22 } + +mtrapargsOctetString OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 23 } + +mtrapargsOctetString02 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 24 } + +mtrapargsOctetString03 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 25 } + +mtrapargsOctetString04 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 26 } + +mtrapargsOctetString05 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 27 } + +mtrapargsOctetString06 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 28 } + +mtrapargsOctetString07 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 29 } + +mtrapargsOctetString08 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID allows APC traps to be sent with an octet string argument + that my not be defined in the APC MIB. + + A get of this OID will return a NULL string." + ::= { mtrapargs 30 } + +-- the mfiletransfer group +-- the mfiletransferStatus group +mfiletransferStatusLastTransferResult OBJECT-TYPE + SYNTAX INTEGER { + lastFileTransferResultSuccessful (1), + lastFileTransferResultNotAvailable (2), + lastFileTransferResultFailureUnknown (3), + lastFileTransferResultFailureServerInaccessible (4), + lastFileTransferResultFailureServerAccessDenied (5), + lastFileTransferResultFailureFileNotFound (6), + lastFileTransferResultFailureFileTypeUnknown (7), + lastFileTransferResultFailureFileCorrupted (8) + } + ACCESS read-only + STATUS deprecated + DESCRIPTION + "This OID has been deprecated. + + Once mfiletransferControlInitiateFileTransfer is set to a value other than doNotInitiateFileTransfer + a file transfer of mfiletransferConfigSettingsFilename will be attempted from either a TFTP or FTP + server. + + This OID shows the last attempted file transfer result. + lastFileTransferResultSuccessful (1) means the file transfer was successful. + lastFileTransferResultNotAvailable (2) means that there have been no previous file transfers. + lastFileTransferResultFailureUnknown (3) means that the last file transfer failed for an unknown reason. + lastFileTransferResultFailureServerInaccessible (4) means that the TFTP or FTP server could not be found on the network. + lastFileTransferResultFailureServerAccessDenied (5) means that the TFTP or FTP server denied access. + lastFileTransferResultFailureFileNotFound (6) means that the file could not be located. + lastFileTransferResultFailureFileTypeUnknown (7) means the file was examined, but the contents were unknown. + lastFileTransferResultFailureFileCorrupt (8) means the transferred file was corrupt." + + ::= { mfiletransferStatus 1 } + +-- the mfiletransferConfig group +-- the mfiletransferConfigSettings group + +mfiletransferConfigSettingsFilename OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS deprecated + DESCRIPTION + "This OID has been deprecated. + + The path and name of the file to transfer using the mfiletransferControlInitiateFileTransfer OID. + If the file to transfer exists in the default server directory then the path may be omitted." + + ::= { mfiletransferConfigSettings 1 } + +-- the mfiletransferConfigTFTP group + +mfiletransferConfigTFTPServerAddress OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS deprecated + DESCRIPTION + "This OID has been deprecated. + + The IP Address in dotted decimal notation of the TFTP server involved in the file transfer." + + ::= { mfiletransferConfigTFTP 1 } + +-- the mfiletransferConfigFTP group + +mfiletransferConfigFTPServerAddress OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS deprecated + DESCRIPTION + "This OID has been deprecated. + + The IP Address in dotted decimal notation of the FTP server involved in the file transfer." + + ::= { mfiletransferConfigFTP 1 } + +mfiletransferConfigFTPServerUser OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS deprecated + DESCRIPTION + "This OID has been deprecated. + + The user identification for logging into the FTP server specified with mfiletransferConfigFTPServerAddress." + + ::= { mfiletransferConfigFTP 2 } + +mfiletransferConfigFTPServerPassword OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS deprecated + DESCRIPTION + "This OID has been deprecated. + + The password for logging into the FTP server specified with mfiletransferConfigFTPServerAddress." + + ::= { mfiletransferConfigFTP 3 } + +-- the mfiletransferControl group + +mfiletransferControlInitiateFileTransfer OBJECT-TYPE + SYNTAX INTEGER { + doNotInitiateFileTransfer (1), + initiateFileTransferDownloadViaTFTP (2), + initiateFileTransferDownloadViaFTP (3) + } + ACCESS read-write + STATUS deprecated + DESCRIPTION + "This OID has been deprecated. + + Setting this OID to doNotInitiateFileTransfer (1) will do nothing. + + Setting this OID to initiateFileTransferDownloadViaTFTP (2) will attempt to transfer the file named in + mfiletransferConfigSettingsFilename from the TFTP Server identified in mfiletransferConfigTFTPAddress. + + Setting this OID to initiateFileTransferDownloadViaFTP (3) will attempt to transfer the file named in + mfiletransferConfigSettingsFilename from the FTP Server identified in mfiletransferConfigFTPAddress + using mfiletransferConfigFTPUser and mfiletransferConfigFTPPassword for the FTP Server login process." + + ::= { mfiletransferControl 1 } +-- the battManIdent group + +battManIdentProductName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the battery manager." + ::= { battManIdent 1 } + +battManIdentHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery manager network interface hardware revision. + This value is set at the factory." + ::= { battManIdent 2 } + +battManIdentFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery manager network interface firmware revision. + This value is set at the factory and can change with firmware update." + ::= { battManIdent 3 } + +battManIdentDateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date the battery manager was manufactured in mm/dd/yyyy format. + This value is set at the factory." + ::= { battManIdent 4 } + +battManIdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery manager model number character string. + This value is set at the factory." + ::= { battManIdent 5 } + +battManIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery manager serial number character string. + This value is set at the factory." + ::= { battManIdent 6 } + +-- the battManCalib group +-- system calibration + +battManOhmicValueCorrectionFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The system ohmic value correction factor in percent." + ::= { battManSystemCalib 1 } + +-- unit calibration + +battManUnitCalibTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the battManUnitCalibTable." + ::= { battManUnitCalib 1 } + +battManUnitCalibTable OBJECT-TYPE + SYNTAX SEQUENCE OF BattManUnitCalibEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting calibration information from each unit in the system." + ::= { battManUnitCalib 2 } + +battManUnitCalibEntry OBJECT-TYPE + SYNTAX BattManUnitCalibEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { battManUnitCalibIndex } + ::= { battManUnitCalibTable 1 } + +BattManUnitCalibEntry ::= + SEQUENCE { + battManUnitCalibIndex INTEGER, + battManUnitSerialNumber DisplayString, + battManBatteryVoltageZeroCalib INTEGER, + battManBatteryVoltageSpanCalib INTEGER + } + +battManUnitCalibIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of unit calibration entries in the table." + ::= { battManUnitCalibEntry 1 } + +battManUnitSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the unit." + ::= { battManUnitCalibEntry 2 } + +battManBatteryVoltageZeroCalib OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The unit battery voltage zero calibration in millivolts." + ::= { battManUnitCalibEntry 3 } + +battManBatteryVoltageSpanCalib OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The unit battery voltage span calibration in hundredths of percent." + ::= { battManUnitCalibEntry 4 } + +-- string calibration table + +battManStringCalibTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the battManStringCalibTable." + ::= { battManStringCalib 1 } + +battManStringCalibTable OBJECT-TYPE + SYNTAX SEQUENCE OF BattManStringCalibEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting calibration information from each string in the system." + ::= { battManStringCalib 2 } + +battManStringCalibEntry OBJECT-TYPE + SYNTAX BattManStringCalibEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The string to get data from." + INDEX { battManStringCalibIndex } + ::= { battManStringCalibTable 1 } + +BattManStringCalibEntry ::= + SEQUENCE { + battManStringCalibIndex INTEGER, + battManDCCurrentZeroCalib INTEGER, + battManACCurrentZeroCalib INTEGER, + battManProbeRange INTEGER + } + +battManStringCalibIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of string calibration entries in the table." + ::= { battManStringCalibEntry 1 } + +battManDCCurrentZeroCalib OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The string DC current zero calibration in tenths of amps." + ::= { battManStringCalibEntry 2 } + +battManACCurrentZeroCalib OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The string AC current zero calibration in tenths of amps." + ::= { battManStringCalibEntry 3 } + +battManProbeRange OBJECT-TYPE + SYNTAX INTEGER { + amps1000 (1), + amps500 (2), + amps100 (3), + amps200 (4), + amps2000 (5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The string probe range in amps." + ::= { battManStringCalibEntry 4 } + +--string 1 battery calibration table + +battManString1BatteryCalibTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the battManString1BatteryCalibTable." + ::= { battManBatteryCalib 1 } + +battManString1BatteryCalibTable OBJECT-TYPE + SYNTAX SEQUENCE OF BattManString1BatteryCalibEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting calibration information from each battery in String 1." + ::= { battManBatteryCalib 2 } + +battManString1BatteryCalibEntry OBJECT-TYPE + SYNTAX BattManString1BatteryCalibEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The string to get data from." + INDEX { battManString1BatteryCalibIndex } + ::= { battManString1BatteryCalibTable 1 } + +BattManString1BatteryCalibEntry ::= + SEQUENCE { + battManString1BatteryCalibIndex INTEGER, + battManString1BatteryInterTierOhmicValue INTEGER + } + +battManString1BatteryCalibIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of battery calibration entries in the table." + ::= { battManString1BatteryCalibEntry 1 } + +battManString1BatteryInterTierOhmicValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The battery inter-tier ohmic value in ohms. This corresponds to the ohmic + value for the positive terminal of the battery." + ::= { battManString1BatteryCalibEntry 2 } + +--string 2 battery calibration table + +battManString2BatteryCalibTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the battManString2BatteryCalibTable." + ::= { battManBatteryCalib 3 } + +battManString2BatteryCalibTable OBJECT-TYPE + SYNTAX SEQUENCE OF BattManString2BatteryCalibEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting calibration information from each battery in String 2." + ::= { battManBatteryCalib 4 } + +battManString2BatteryCalibEntry OBJECT-TYPE + SYNTAX BattManString2BatteryCalibEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The string to get data from." + INDEX { battManString2BatteryCalibIndex } + ::= { battManString2BatteryCalibTable 1 } + +BattManString2BatteryCalibEntry ::= + SEQUENCE { + battManString2BatteryCalibIndex INTEGER, + battManString2BatteryInterTierOhmicValue INTEGER + } + +battManString2BatteryCalibIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of battery calibration entries in the table." + ::= { battManString2BatteryCalibEntry 1 } + +battManString2BatteryInterTierOhmicValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The battery inter-tier ohmic value in ohms." + ::= { battManString2BatteryCalibEntry 2 } + +-- the battManConfig group + +battManConfigApplication OBJECT-TYPE + SYNTAX INTEGER { + silcon (1), + other (2) + } + ACCESS read-write + STATUS deprecated + DESCRIPTION + "This OID has been deprecated." + ::= { battManConfig 1 } + +battManConfigBatteryChemistry OBJECT-TYPE + SYNTAX INTEGER { + leadAcid (1), + nickel-Cadmium (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The battery chemistry of the monitored batteries: + LeadAcid(1) Lead Acid or + Nickel-Cadmium(2) Nickel-Cadmium." + ::= { battManConfig 2 } + +battManConfigBatteryAHCapacity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amp hour capacity of the monitored batteries 5-4000 AH." + ::= { battManConfig 3 } + +battManConfigNumberofStrings OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of strings in the battery manager system." + ::= { battManConfig 4 } + +battManConfigBatteriesperString OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of batteries per string." + ::= { battManConfig 5 } + + +battManConfigCellsperBattery OBJECT-TYPE + SYNTAX INTEGER { + oneCell (1), + twoCells (2), + fourCells (4), + sixCells (6) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of cells per battery (1, 2, 4 or 6 for lead-acid, 1 or 2 for NiCd." + ::= { battManConfig 6 } + + +battManConfigMinCellVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The minimum battery cell voltage alarm limit in millivolts DC." + ::= { battManConfig 7 } + +battManConfigMaxCellVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum battery cell voltage alarm limit in millivolts DC." + ::= { battManConfig 8 } + +battManConfigMaxPilotTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum pilot battery temperature alarm limit in tenths of degrees Fahrenheit." + ::= { battManConfig 9 } + +battManConfigMaxPilotTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum pilot battery temperature alarm limit in tenths of degrees Celsius." + ::= { battManConfig 10 } + +battManConfigMaxAmbientTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum ambient temperature alarm limit in tenths of degrees Fahrenheit." + ::= { battManConfig 11 } + +battManConfigMaxAmbientTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum ambient temperature alarm limit in tenths of degrees Celsius." + ::= { battManConfig 12 } + +battManConfigMinAmbientTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The Minimum Ambient Temperature alarm limit in tenths of degrees Fahrenheit." + ::= { battManConfig 13 } + +battManConfigMinAmbientTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The Minimum Ambient Temperature alarm limit in tenths of degrees Celsius." + ::= { battManConfig 14 } + +battManConfigMaxRippleCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum ripple current alarm limit for the monitored battery + strings in percent of AH capacity." + ::= { battManConfig 15 } + +battManConfigMaxCurrentAcceptanceDeviation OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum current acceptance deviation alarm limit in percent." + ::= { battManConfig 16 } + +battManConfigMonitorWireLength OBJECT-TYPE + SYNTAX INTEGER { + fiftyFeetOrLess (1), + moreThanFiftyFeet (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The monitor wire length: + fiftyFeetOrLess (1) indicates that the wire length is less than or equal to 50 feet. + moreThanFiftyFeet (2) indicates that the wire length is greater than 50 feet." + ::= { battManConfig 17 } + +battManConfigDischargeVoltageAlarmLevel OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The discharge voltage alarm level in percent." + ::= { battManConfig 18 } + +battManConfigAutoAnnunciatorReset OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The annunciator output signal reset method: + disabled(1) means the annunciator signal output will be reset when the reset button is pressed. + enabled(2) means the annunciator will stop signaling when all alarm conditions clear." + ::= { battManConfig 19 } + +battManConfigSuspendCellVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This is used along with the number of cells per battery + and the number of batteries per string to determine if + a battery string has violated the low voltage limit. If + so, the Battery Management System will enter suspend mode. + Measured in millivolts DC" + ::= { battManConfig 20 } + +battManConfigOhmicTestWaitTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of time in seconds after a discharge event before + data will be collected for the ohmic value calculation." + ::= { battManConfig 21 } + +battManConfigNumberOfBoosts OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of consecutive times the Battery Management + System applies a charge to each battery during a boost + cycle. Batteries with a Rated Battery AH Capacity + less than or equal to 120 AH will always have a value + of one for Number of Boosts." + ::= { battManConfig 22 } + +-- the battManAlarm group + +battManAlarmManagementController OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Management Controller Alarm is : + normal(1) no alarm conditions identified + alarm(2) an alarm condition exists." + ::= { battManAlarm 1 } + +battManAlarmBatteries OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Batteries Alarm is : + normal(1) no alarm conditions identified + alarm(2) an alarm condition exists." + ::= { battManAlarm 2 } + +battManAlarmCharger OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Charger Alarm is : + normal(1) no alarm conditions identified + alarm(2) an alarm condition exists." + ::= { battManAlarm 3 } + +battManAlarmEnvironment OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Environment Alarm is : + normal(1) no alarm conditions identified + alarm(2) an alarm condition exists." + ::= { battManAlarm 4 } + +-- the battManSystemStatus group + +-- These are system wide parameters + +battManSystemAmbientTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system ambient temperature in tenths of degrees Celsius." + ::= { battManSystemStatus 1 } + +battManSystemAmbientTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system ambient temperature in tenths of degrees Fahrenheit." + ::= { battManSystemStatus 2 } + +battManSystemPilotTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system pilot temperature in tenths of degrees Celsius." + ::= { battManSystemStatus 3 } + +battManSystemPilotTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system pilot temperature in tenths of degrees Fahrenheit." + ::= { battManSystemStatus 4 } + +battManSystemAmbientHighTempAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that the system has a high temperature alarm." + ::= { battManSystemStatus 5 } + +battManSystemAmbientLowTempAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that the system has a low temperature alarm." + ::= { battManSystemStatus 6 } + +battManSystemPilotBatteryHighTempAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that the system has a pilot battery high temperature alarm." + ::= { battManSystemStatus 7 } + +battManSystemPilotProbeDisconnected OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that the system pilot probe is disconnected." + ::= { battManSystemStatus 8 } + +battManSystemAmbientProbeDisconnected OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that the system ambient probe is disconnected." + ::= { battManSystemStatus 9 } + +battManSystemConfigurationInvalid OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that the system is not configured correctly." + ::= { battManSystemStatus 10 } + +battManSystemSuspendVoltage OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that the system has suspended voltage scans." + ::= { battManSystemStatus 11 } + +-- This is a table of input contact parameters + +battManInputContactTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the battManInputContactTable." + ::= { battManInputContactStatus 1 } + +battManInputContactTable OBJECT-TYPE + SYNTAX SEQUENCE OF BattManInputContactEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each contact + in the system. " + ::= { battManInputContactStatus 2 } + +battManInputContactEntry OBJECT-TYPE + SYNTAX BattManInputContactEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The contact to get data from." + INDEX { battManInputContactIndex } + ::= { battManInputContactTable 1 } + +BattManInputContactEntry ::= + SEQUENCE { + battManInputContactIndex INTEGER, + battManInputContactName DisplayString, + battManInputContactAlarmState INTEGER, + battManInputContactState INTEGER, + battManInputContactNormalState INTEGER, + battManInputContactAlarmDelay INTEGER + } + +battManInputContactIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of contact entries in the table." + ::= { battManInputContactEntry 1 } + +battManInputContactName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the input contact." + ::= { battManInputContactEntry 2 } + +battManInputContactAlarmState OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that the alarm condition is active for this contact." + ::= { battManInputContactEntry 3 } + +battManInputContactState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to open(1), the input contact is in the open state. + When set to closed(2), the input contact is in the closed state." + ::= { battManInputContactEntry 4 } + +battManInputContactNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When set to open(1), the input contact is normally open. + When set to closed(2), the input contact is normally closed." + ::= { battManInputContactEntry 5 } + +battManInputContactAlarmDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The input contact alarm delay time in seconds." + ::= { battManInputContactEntry 6 } + +-- This is a table of battery string parameters + +battManStringTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the battManStringTable." + ::= { battManStringStatus 1 } + +battManStringTable OBJECT-TYPE + SYNTAX SEQUENCE OF BattManStringEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each string + in the system. " + ::= { battManStringStatus 2 } + +battManStringEntry OBJECT-TYPE + SYNTAX BattManStringEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The string to get data from." + INDEX { battManStringIndex } + ::= { battManStringTable 1 } + +BattManStringEntry ::= + SEQUENCE { + battManStringIndex INTEGER, + battManStringCurrent INTEGER, + battManStringRippleCurrent INTEGER, + battManStringChargerHighVoltageAlarm INTEGER, + battManStringChargerLowVoltageAlarm INTEGER, + battManStringCurrentProbeDisconnected INTEGER, + battManStringOnBattery INTEGER, + battManStringHighRippleCurrent INTEGER, + battManStringVoltage INTEGER, + battManStringDischargeLess5Seconds INTEGER, + battManStringDischarge5to10Seconds INTEGER, + battManStringDischarge10to60Seconds INTEGER, + battManStringDischargeMore60Seconds INTEGER + } + +battManStringIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of string entries in the table." + ::= { battManStringEntry 1 } + +battManStringCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The string current in tenths of amps." + ::= { battManStringEntry 2 } + +battManStringRippleCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The string ripple current in tenths of amps." + ::= { battManStringEntry 3 } + +battManStringChargerHighVoltageAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that the string charger has a high voltage alarm." + ::= { battManStringEntry 4 } + +battManStringChargerLowVoltageAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that the string charger has a low voltage alarm." + ::= { battManStringEntry 5 } + +battManStringCurrentProbeDisconnected OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that the string charger probe is disconnected." + ::= { battManStringEntry 6 } + +battManStringOnBattery OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that the string is in the on-battery state." + ::= { battManStringEntry 7 } + +battManStringHighRippleCurrent OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that the string has a high ripple current." + ::= { battManStringEntry 8 } + +battManStringVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The sum of the voltages for all of the batteries on a + string in millivolts DC." + ::= { battManStringEntry 9 } + +battManStringDischargeLess5Seconds OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of recorded discharges lasting less than + 5 seconds." + ::= { battManStringEntry 10 } + +battManStringDischarge5to10Seconds OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of recorded discharges lasting between 5 + and 10 seconds." + ::= { battManStringEntry 11 } + +battManStringDischarge10to60Seconds OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of recorded discharges lasting between 10 + and 60 seconds." + ::= { battManStringEntry 12 } + +battManStringDischargeMore60Seconds OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of recorded discharges lasting more than + 60 seconds (1 minute)." + ::= { battManStringEntry 13 } + +-- the battManString1BatteryStatus group + +battManString1BatteryTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the battManString1BatteryTable." + ::= { battManBatteryStatus 1 } + +battManString1BatteryTable OBJECT-TYPE + SYNTAX SEQUENCE OF BattManString1BatteryEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each string + in the system. " + ::= { battManBatteryStatus 2 } + +battManString1BatteryEntry OBJECT-TYPE + SYNTAX BattManString1BatteryEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The string to get data from." + INDEX { battManString1BatteryIndex } + ::= { battManString1BatteryTable 1 } + +BattManString1BatteryEntry ::= + SEQUENCE { + battManString1BatteryIndex INTEGER, + battManString1BatteryVoltage INTEGER, + battManString1BatteryLowestVoltage INTEGER, + battManString1BatteryCellShorted INTEGER, + battManString1BatteryOpenFuseOrConnection INTEGER, + battManString1BatteryLowCapacity INTEGER, + battManString1BatteryHighOhmicValue INTEGER, + battManString1BatteryThermalRunaway INTEGER, + battManString1BatteryDryout INTEGER, + battManString1BatteryUserHighVoltageAlarm INTEGER, + battManString1BatteryUserLowVoltageAlarm INTEGER, + battManString1BatteryChemHighVoltageAlarm INTEGER, + battManString1BatteryChemLowVoltageAlarm INTEGER, + battManString1BatteryOpenCell INTEGER + } + +battManString1BatteryIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of string entries in the table." + ::= { battManString1BatteryEntry 1 } + +battManString1BatteryVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery voltage in millivolts DC." + ::= { battManString1BatteryEntry 2 } + +battManString1BatteryLowestVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The lowest battery discharge voltage during the last power event in millivolts DC." + ::= { battManString1BatteryEntry 3 } + +battManString1BatteryCellShorted OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that a battery cell is shorted." + ::= { battManString1BatteryEntry 4 } + +battManString1BatteryOpenFuseOrConnection OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that a fuse or connection is open." + ::= { battManString1BatteryEntry 5 } + +battManString1BatteryLowCapacity OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has low capacity." + ::= { battManString1BatteryEntry 6 } + +battManString1BatteryHighOhmicValue OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has a high ohmic value." + ::= { battManString1BatteryEntry 7 } + +battManString1BatteryThermalRunaway OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has a thermal runaway condition." + ::= { battManString1BatteryEntry 8 } + +battManString1BatteryDryout OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has a dryout condition." + ::= { battManString1BatteryEntry 9 } + +battManString1BatteryUserHighVoltageAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has violated + the user level high voltage limit." + ::= { battManString1BatteryEntry 10 } + +battManString1BatteryUserLowVoltageAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has violated + the user level low voltage limit." + ::= { battManString1BatteryEntry 11 } + +battManString1BatteryChemHighVoltageAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has violated + the chemistry level high voltage limit." + ::= { battManString1BatteryEntry 12 } + +battManString1BatteryChemLowVoltageAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has violated + the chemistry level low voltage limit." + ::= { battManString1BatteryEntry 13 } + +battManString1BatteryOpenCell OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates the battery has an open + cell or an inter-connection is abnormal." + ::= { battManString1BatteryEntry 14 } + + +-- the battManString2BatteryStatus group + +battManString2BatteryTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the battManString2BatteryTable." + ::= { battManBatteryStatus 3 } + +battManString2BatteryTable OBJECT-TYPE + SYNTAX SEQUENCE OF BattManString2BatteryEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each string + in the system. " + ::= { battManBatteryStatus 4 } + +battManString2BatteryEntry OBJECT-TYPE + SYNTAX BattManString2BatteryEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The string to get data from." + INDEX { battManString2BatteryIndex } + ::= { battManString2BatteryTable 1 } + +BattManString2BatteryEntry ::= + SEQUENCE { + battManString2BatteryIndex INTEGER, + battManString2BatteryVoltage INTEGER, + battManString2BatteryLowestVoltage INTEGER, + battManString2BatteryCellShorted INTEGER, + battManString2BatteryOpenFuseOrConnection INTEGER, + battManString2BatteryLowCapacity INTEGER, + battManString2BatteryHighOhmicValue INTEGER, + battManString2BatteryThermalRunaway INTEGER, + battManString2BatteryDryout INTEGER, + battManString2BatteryUserHighVoltageAlarm INTEGER, + battManString2BatteryUserLowVoltageAlarm INTEGER, + battManString2BatteryChemHighVoltageAlarm INTEGER, + battManString2BatteryChemLowVoltageAlarm INTEGER, + battManString2BatteryOpenCell INTEGER + } + +battManString2BatteryIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of string entries in the table." + ::= { battManString2BatteryEntry 1 } + +battManString2BatteryVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery voltage in millivolts DC." + ::= { battManString2BatteryEntry 2 } + +battManString2BatteryLowestVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The lowest battery discharge voltage during the last power event in millivolts DC." + ::= { battManString2BatteryEntry 3 } + +battManString2BatteryCellShorted OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that a battery cell is shorted." + ::= { battManString2BatteryEntry 4 } + +battManString2BatteryOpenFuseOrConnection OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates that a fuse or connection is open." + ::= { battManString2BatteryEntry 5 } + +battManString2BatteryLowCapacity OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has low capacity." + ::= { battManString2BatteryEntry 6 } + +battManString2BatteryHighOhmicValue OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has a high ohmic value." + ::= { battManString2BatteryEntry 7 } + +battManString2BatteryThermalRunaway OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has a thermal runaway condition." + ::= { battManString2BatteryEntry 8 } + +battManString2BatteryDryout OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has a dryout condition." + ::= { battManString2BatteryEntry 9 } + +battManString2BatteryUserHighVoltageAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has violated + the user level high voltage limit." + ::= { battManString2BatteryEntry 10 } + +battManString2BatteryUserLowVoltageAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has violated + the user level low voltage limit." + ::= { battManString2BatteryEntry 11 } + +battManString2BatteryChemHighVoltageAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has violated + the chemistry level high voltage limit." + ::= { battManString2BatteryEntry 12 } + +battManString2BatteryChemLowVoltageAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates a battery has violated + the chemistry level low voltage limit." + ::= { battManString2BatteryEntry 13 } + +battManString2BatteryOpenCell OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates the battery has an open + cell or an inter-connection is abnormal." + ::= { battManString2BatteryEntry 14 } + +-- battery manager control group +battManRemoteAnnunciatorReset OBJECT-TYPE + SYNTAX INTEGER { + noOperation (1), + reset (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset(2) will reset the user interface annunciator. + Getting this OID will do nothing and return the noOperation(1) value." + ::= { battManControl 1 } + +battManResetChargeCurrentDeviationBenchmark OBJECT-TYPE + SYNTAX INTEGER { + noOperation (1), + reset (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset(2) will reset the charge current deviation benchmark. + Getting this OID will do nothing and return the noOperation(1) value." + ::= { battManControl 2 } + +battManResetLowestDischargeVoltages OBJECT-TYPE + SYNTAX INTEGER { + noOperation (1), + reset (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset(2) will reset the lowest discharge voltages. + Getting this OID will do nothing and return the noOperation(1) value." + ::= { battManControl 3 } + +battManResetDischargeCounters OBJECT-TYPE + SYNTAX INTEGER { + noOperation (1), + reset (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset(2) will reset all discharge event counters. + Getting this OID will do nothing and return the noOperation(1) value." + ::= { battManControl 4 } + +-- the battManTestResults group + +--string 1 test results table + +battManString1OhmicValueLastDischargeInfo OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Informational text showing the date/time, load, and pilot temperature for the string + during the last discharge when ohmic values were recorded." + ::= { battManTestResults 1 } + +battManString1OhmicValueTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the battManString1OhmicValueTable." + ::= { battManTestResults 2 } + +battManString1OhmicValueTable OBJECT-TYPE + SYNTAX SEQUENCE OF BattManString1OhmicValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting ohmic value information from each battery in String 1." + ::= { battManTestResults 3 } + +battManString1OhmicValueEntry OBJECT-TYPE + SYNTAX BattManString1OhmicValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The string to get data from." + INDEX { battManString1OhmicValueIndex } + ::= { battManString1OhmicValueTable 1 } + +BattManString1OhmicValueEntry ::= + SEQUENCE { + battManString1OhmicValueIndex INTEGER, + battManString1OhmicValueData INTEGER + } + +battManString1OhmicValueIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery number." + ::= { battManString1OhmicValueEntry 1 } + +battManString1OhmicValueData OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery inter-tier ohmic value in ohms. + Note: Zero or negative values are invalid and may indicate + faulty calibration of ohmic value correction factors." + ::= { battManString1OhmicValueEntry 2 } + +battManString1ResponseTestChangeTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the battManString1ResponseTestChangeTable." + ::= { battManTestResults 4 } + +battManString1ResponseTestChangeTable OBJECT-TYPE + SYNTAX SEQUENCE OF BattManString1ResponseTestChangeEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting response test change information from each battery in String 1." + ::= { battManTestResults 5 } + +battManString1ResponseTestChangeEntry OBJECT-TYPE + SYNTAX BattManString1ResponseTestChangeEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The string to get data from." + INDEX { battManString1ResponseTestChangeIndex } + ::= { battManString1ResponseTestChangeTable 1 } + +BattManString1ResponseTestChangeEntry ::= + SEQUENCE { + battManString1ResponseTestChangeIndex INTEGER, + battManString1ResponseTestChangeData INTEGER + } + +battManString1ResponseTestChangeIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of the entries in the table." + ::= { battManString1ResponseTestChangeEntry 1 } + +battManString1ResponseTestChangeData OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery response test change in percent." + ::= { battManString1ResponseTestChangeEntry 2 } + +battManString2OhmicValueLastDischargeInfo OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Informational text showing the date/time, load, and pilot temperature for the string + during the last discharge when ohmic values were recorded." + ::= { battManTestResults 6 } + +battManString2OhmicValueTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the battManString2OhmicValueTable." + ::= { battManTestResults 7 } + +battManString2OhmicValueTable OBJECT-TYPE + SYNTAX SEQUENCE OF BattManString2OhmicValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting ohmic value information from each battery in String 2." + ::= { battManTestResults 8 } + +battManString2OhmicValueEntry OBJECT-TYPE + SYNTAX BattManString2OhmicValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The string to get data from." + INDEX { battManString2OhmicValueIndex } + ::= { battManString2OhmicValueTable 1 } + +BattManString2OhmicValueEntry ::= + SEQUENCE { + battManString2OhmicValueIndex INTEGER, + battManString2OhmicValueData INTEGER + } + +battManString2OhmicValueIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of battery calibration entries in the table." + ::= { battManString2OhmicValueEntry 1 } + +battManString2OhmicValueData OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery inter-tier ohmic value in ohms. + Note: Zero or negative values are invalid and may indicate + faulty calibration of ohmic value correction factors." + ::= { battManString2OhmicValueEntry 2 } + +battManString2ResponseTestChangeTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the battManString2ResponseTestChangeTable." + ::= { battManTestResults 9 } + +battManString2ResponseTestChangeTable OBJECT-TYPE + SYNTAX SEQUENCE OF BattManString2ResponseTestChangeEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting response test change information from each battery in String 2." + ::= { battManTestResults 10 } + +battManString2ResponseTestChangeEntry OBJECT-TYPE + SYNTAX BattManString2ResponseTestChangeEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The string to get data from." + INDEX { battManString2ResponseTestChangeIndex } + ::= { battManString2ResponseTestChangeTable 1 } + +BattManString2ResponseTestChangeEntry ::= + SEQUENCE { + battManString2ResponseTestChangeIndex INTEGER, + battManString2ResponseTestChangeData INTEGER + } + +battManString2ResponseTestChangeIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of the entries in the table." + ::= { battManString2ResponseTestChangeEntry 1 } + +battManString2ResponseTestChangeData OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery response test change in percent." + ::= { battManString2ResponseTestChangeEntry 2 } + + +-- battManUnitStatus + +battManUnitStatusTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the battManUnitStatusTable." + ::= { battManUnitStatus 1 } + +battManUnitStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF BattManUnitStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting status information from each unit in the system." + ::= { battManUnitStatus 2 } + +battManUnitStatusEntry OBJECT-TYPE + SYNTAX BattManUnitStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { battManUnitStatusIndex } + ::= { battManUnitStatusTable 1 } + +BattManUnitStatusEntry ::= + SEQUENCE { + battManUnitStatusIndex INTEGER, + battManUnitStatusSerialNumber DisplayString, + battManUnitHardwareRev INTEGER, + battManUnitFirmwareRev INTEGER, + battManUnitCommLoss INTEGER, + battManUnitRelayStuck INTEGER + } + +battManUnitStatusIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of unit status entries in the table." + ::= { battManUnitStatusEntry 1 } + +battManUnitStatusSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery manager unit serial number character string. + This value is set at the factory." + ::= { battManUnitStatusEntry 2 } + +battManUnitHardwareRev OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery manager unit hardware revision. + This value is set at the factory." + ::= { battManUnitStatusEntry 3 } + +battManUnitFirmwareRev OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery manager unit firmware revision. + This value is set at the factory and can change with firmware update." + ::= { battManUnitStatusEntry 4 } + +battManUnitCommLoss OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates the system has lost + communication with the unit." + ::= { battManUnitStatusEntry 5 } + +battManUnitRelayStuck OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When set to alarm(2), indicates the unit monitor relay + is stuck." + ::= { battManUnitStatusEntry 6 } + + +-- the xPDUIdent group + +xPDUIdentProductName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the PDU." + ::= { xPDUIdent 1 } + +xPDUIdentHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the PDU. + This value is set at the factory." + ::= { xPDUIdent 2 } + +xPDUIdentFirmwareAppRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ID string identifying the application firmware revision of the PDU." + ::= { xPDUIdent 3 } + +xPDUIdentFirmwareAppOSRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ID string identifying the application operating system firmware revision of the PDU." + ::= { xPDUIdent 4 } + +xPDUIdentFirmwareControllerRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ID string identifying the PDU controller firmware revision." + ::= { xPDUIdent 5 } + +xPDUIdentDateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date when the PDU was manufactured in mm/dd/yyyy format. + This value is set at the factory." + ::= { xPDUIdent 6 } + +xPDUIdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the model number of + the PDU. This value is set at the factory." + ::= { xPDUIdent 7 } + +xPDUIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the serial number of + the PDU. This value is set at the factory." + ::= { xPDUIdent 8 } + +-- the xPDUDevice group + +xPDUDeviceNominalMainInputVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal main input voltage to the PDU. Measured in Volts, + line-to-line for a 3-wire (delta) service or line-to-neutral for a + 4-wire (wye) service." + ::= { xPDUDevice 1 } + +xPDUDeviceServiceType OBJECT-TYPE + SYNTAX INTEGER { + threeWire (1), + fourWire (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of utility input to the PDU. Either 3 wires (delta), or 4 wires (wye)." + ::= { xPDUDevice 2 } + +xPDUDeviceNominalOutputVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal line-to-neutral output voltage to the load measured in Volts." + ::= { xPDUDevice 3 } + +xPDUDeviceMainInputBreakerRating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The rating of the main input breaker measured in Amps." + ::= { xPDUDevice 4 } + +xPDUDevicePanelBreakerRating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The rating of the panel breaker measured in Amps." + ::= { xPDUDevice 5 } + +xPDUDeviceTransformerPresent OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + present (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not a transformer is installed in the PDU." + ::= { xPDUDevice 6 } + +xPDUDeviceLoadTieBreakerPresent OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + present (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not a load tie breaker is installed in the PDU." + ::= { xPDUDevice 7 } + +xPDUDeviceLoadTestPortPresent OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + present (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not a load test port is installed in the PDU." + ::= { xPDUDevice 8 } + +xPDUDeviceFusesPresent OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + present (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not the UPS feed from the PDU includes fuses." + ::= { xPDUDevice 9 } + +xPDUDeviceFansPresent OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + present (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not cooling fans are installed in the PDU." + ::= { xPDUDevice 10 } + +xPDUDeviceBypassInputPresent OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + present (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not the PDU is equipped with a second feed for + the UPS's bypass input." + ::= { xPDUDevice 11 } + +xPDUDeviceCrossTieOutputPresent OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + present (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not the PDU is equipped with a cross-tie output." + ::= { xPDUDevice 12 } + +xPDUDeviceEarthGroundMonitorPresent OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + present (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not the PDU can provide ground current measurements." + ::= { xPDUDevice 13 } + +xPDUDeviceInfraStruXureType OBJECT-TYPE + SYNTAX INTEGER { + typeB (1), + typeC (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the configuration of this PDU system. + Type-B PDU is in a distributed UPS system and has bypass capabilities. + Type-C PDU receives power from a larger central UPS." + ::= { xPDUDevice 14 } + +-- Main Input + +xPDUMainInputOverVoltThreshold OBJECT-TYPE + SYNTAX INTEGER (0..30) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold above which an input over voltage condition will be generated. + Specified as percent deviation from nominal." + ::= { xPDUMainInput 1 } + +xPDUMainInputUnderVoltThreshold OBJECT-TYPE + SYNTAX INTEGER (0..30) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold below which an input under voltage condition will be generated. + Specified as percent deviation from nominal. + A value of zero indicates that the threshold is disabled." + ::= { xPDUMainInput 2 } + +-- Main Input Voltage Table + +xPDUMainInputVoltageTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Main input voltage entries." + ::= { xPDUMainInput 3 } + +xPDUMainInputVoltagePhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF XPDUMainInputVoltagePhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of input voltage table entries. The number of + entries are the phase entries. + The number of entries is contained in the + xPDUMainInputVoltageTableSize OID." + ::= { xPDUMainInput 4 } + + xPDUMainInputVoltagePhaseEntry OBJECT-TYPE + SYNTAX XPDUMainInputVoltagePhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular main input voltage phase." + INDEX { xPDUMainInputVoltagePhaseIndex } + ::= { xPDUMainInputVoltagePhaseTable 1 } + + XPDUMainInputVoltagePhaseEntry ::= SEQUENCE { + xPDUMainInputVoltagePhaseIndex INTEGER, + xPDUMainInputVoltageLtoL INTEGER, + xPDUMainInputVoltageLtoN INTEGER + } + + xPDUMainInputVoltagePhaseIndex OBJECT-TYPE + SYNTAX INTEGER{ + phase1(1), + phase2(2), + phase3(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of each input phase entry in the table." + ::= { xPDUMainInputVoltagePhaseEntry 1 } + + xPDUMainInputVoltageLtoL OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Line-to-line PDU input voltage when an isolation transformer is present, + or -1 if no transformer present in this PDU. Measured in tenths of Volts." + ::= { xPDUMainInputVoltagePhaseEntry 2 } + + xPDUMainInputVoltageLtoN OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Line-to-neutral PDU input voltage when an isolation transformer is not present, + or -1 if a transformer is present in this PDU. Measured in tenths of Volts." + ::= { xPDUMainInputVoltagePhaseEntry 3 } + + +xPDUBypassInputOverVoltThreshold OBJECT-TYPE + SYNTAX INTEGER (0..30) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold above which a bypass input over voltage condition will be generated. + Specified as percent deviation from nominal." + ::= { xPDUBypassInput 1 } + +xPDUBypassInputUnderVoltThreshold OBJECT-TYPE + SYNTAX INTEGER (0..30) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold below which an bypass input under voltage condition will be generated. + Specified as percent deviation from nominal. + A value of zero indicates that the threshold is disabled." + ::= { xPDUBypassInput 2 } + +-- Bypass Input Voltage Table + +xPDUBypassInputVoltagePhaseTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of bypass input voltage entries." + ::= { xPDUBypassInput 3 } + +xPDUBypassInputVoltagePhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF XPDUBypassInputVoltagePhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of output table entries. The number of + entries are the phase entries. + The number of entries is contained in the + xPDUBypassInputVoltagePhaseTableSize OID." + ::= { xPDUBypassInput 4 } + + xPDUBypassInputVoltagePhaseEntry OBJECT-TYPE + SYNTAX XPDUBypassInputVoltagePhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular bypass input voltage phase." + INDEX { xPDUBypassInputVoltagePhaseIndex } + ::= { xPDUBypassInputVoltagePhaseTable 1 } + + XPDUBypassInputVoltagePhaseEntry ::= SEQUENCE { + xPDUBypassInputVoltagePhaseIndex INTEGER, + xPDUBypassInputVoltageLtoL INTEGER, + xPDUBypassInputVoltageLtoN INTEGER + } + + xPDUBypassInputVoltagePhaseIndex OBJECT-TYPE + SYNTAX INTEGER{ + phase1(1), + phase2(2), + phase3(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of each bypass input phase entry in the table." + ::= { xPDUBypassInputVoltagePhaseEntry 1 } + + xPDUBypassInputVoltageLtoL OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Line-to-line bypass input voltage, or -1 if no bypass + feed is present in this PDU. Measured in tenths of Volts." + ::= { xPDUBypassInputVoltagePhaseEntry 2 } + + xPDUBypassInputVoltageLtoN OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Line-to-neutral bypass input voltage, or -1 if no bypass + feed is present in this PDU. Measured in tenths of Volts." + ::= { xPDUBypassInputVoltagePhaseEntry 3 } + +-- UPS Input Table + +xPDUUPSInputVoltagePhaseTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of UPS input voltage entries." + ::= { xPDUUPSInput 1 } + +xPDUUPSInputVoltagePhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF XPDUUPSInputVoltagePhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of UPS input table entries. The number of + entries are the phase entries. + The number of entries is contained in the + xPDUUPSInputVoltagePhaseTableSize OID." + ::= { xPDUUPSInput 2 } + + xPDUUPSInputVoltagePhaseEntry OBJECT-TYPE + SYNTAX XPDUUPSInputVoltagePhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular UPS input voltage phase." + INDEX { xPDUUPSInputVoltagePhaseIndex } + ::= { xPDUUPSInputVoltagePhaseTable 1 } + + XPDUUPSInputVoltagePhaseEntry ::= SEQUENCE { + xPDUUPSInputVoltagePhaseIndex INTEGER, + xPDUUPSInputVoltageLtoNPresent INTEGER + } + + xPDUUPSInputVoltagePhaseIndex OBJECT-TYPE + SYNTAX INTEGER{ + phase1(1), + phase2(2), + phase3(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of each UPS input phase entry in the table." + ::= { xPDUUPSInputVoltagePhaseEntry 1 } + + xPDUUPSInputVoltageLtoNPresent OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + present (2), + unknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not voltage is present at the UPS feed." + ::= { xPDUUPSInputVoltagePhaseEntry 2 } + +-- System Output + +xPDUSystemOutputFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system output frequency in tenths of Hertz." + ::= { xPDUSystemOutput 1 } + +xPDUSystemOutputNeutralCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Shows the neutral current measured at the system output in tenths of Amps." + ::= { xPDUSystemOutput 2 } + +xPDUSystemOutputTotalPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Shows the total system output power in tenths of kW." + ::= { xPDUSystemOutput 3 } + +xPDUSystemOutputTotalApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Shows the total system output power in tenths of kVA." + ::= { xPDUSystemOutput 4 } + +xPDUSystemOutputTotalPowerFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the total power factor of the system output. + A value of 100 representing a unity power factor (1.00). + Measured in hundredths." + ::= { xPDUSystemOutput 5 } + +xPDUSystemOutputFrequencyTolerance OBJECT-TYPE + SYNTAX INTEGER{ + freqToleranceOff (1), + freqTolerancePointTwo (2), + freqTolerancePointFive (3), + freqToleranceOne (4), + freqToleranceOnePointFive (5), + freqToleranceTwo (6), + freqToleranceThree (7), + freqToleranceFour (8), + freqToleranceFive (9), + freqToleranceNine (10) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Shows the circuit panel output frequency tolerance in Hertz." + ::= { xPDUSystemOutput 6 } + +xPDUSystemOutputMaxKWPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Defines 100% load in kW. + Purpose is to set to match UPS capabilities." + ::= { xPDUSystemOutput 7 } + +xPDUSystemOutputOverVoltThreshold OBJECT-TYPE + SYNTAX INTEGER (0..30) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold above which an output over voltage condition will be generated. + Specified as percent deviation from nominal." + ::= { xPDUSystemOutput 8 } + +xPDUSystemOutputUnderVoltThreshold OBJECT-TYPE + SYNTAX INTEGER (0..30) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold below which an output under voltage condition will be generated. + Specified as percent deviation from nominal. + A value of zero indicates that the threshold is disabled." + ::= { xPDUSystemOutput 9 } + + +xPDUSystemOutputOverCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold above which an over current condition will be generated. + Specified as a percent of the panel breaker rating. + A value of zero indicates that the threshold is disabled." + ::= { xPDUSystemOutput 10 } + +xPDUSystemOutputOverCurrentNeutralThreshold OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold above which an Over current neutral condition will be generated. + Specified as a percent of the panel breaker rating. + A value of zero indicates that the threshold is disabled." + ::= { xPDUSystemOutput 11 } + +xPDUSystemOutputUnderCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold below which an under current condition will be generated. + Specified as a percent of the panel breaker rating. + A value of zero indicates that the threshold is disabled." + ::= { xPDUSystemOutput 12 } + +xPDUSystemOutputTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of System Output phase entries." + ::= { xPDUSystemOutput 13 } + +xPDUSystemOutputPhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF XPDUSystemOutputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of system output table entries. + The number of entries is contained in the + xPDUSystemOutputTableSize OID." + ::= { xPDUSystemOutput 14 } + + xPDUSystemOutputPhaseEntry OBJECT-TYPE + SYNTAX XPDUSystemOutputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular system output phase." + INDEX { xPDUSystemOutputPhaseIndex } + ::= { xPDUSystemOutputPhaseTable 1 } + + XPDUSystemOutputPhaseEntry ::= SEQUENCE { + xPDUSystemOutputPhaseIndex INTEGER, + xPDUSystemOutputVoltageLtoL INTEGER, + xPDUSystemOutputVoltageLtoN INTEGER, + xPDUSystemOutputPhaseCurrent INTEGER, + xPDUSystemOutputPower INTEGER, + xPDUSystemOutputApparentPower INTEGER, + xPDUSystemOutputPowerFactor INTEGER + } + + xPDUSystemOutputPhaseIndex OBJECT-TYPE + SYNTAX INTEGER{ + phase1(1), + phase2(2), + phase3(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of each output phase entry in the table." + ::= { xPDUSystemOutputPhaseEntry 1 } + + xPDUSystemOutputVoltageLtoL OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Line-to-line system output voltage available at the circuit panel. + Measured in tenths of Volts." + ::= { xPDUSystemOutputPhaseEntry 2 } + + xPDUSystemOutputVoltageLtoN OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Line-to-neutral system output voltage available at the circuit panel. + Measured in tenths of Volts." + ::= { xPDUSystemOutputPhaseEntry 3 } + + + xPDUSystemOutputPhaseCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "System load current per phase. Measured in tenths of Amps." + ::= { xPDUSystemOutputPhaseEntry 4 } + + xPDUSystemOutputPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "System output power per phase. Measured in tenths of kW." + ::= { xPDUSystemOutputPhaseEntry 5 } + + xPDUSystemOutputApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "System output power per phase. Measured in tenths of kVA." + ::= { xPDUSystemOutputPhaseEntry 6 } + + xPDUSystemOutputPowerFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the Power Factor of the system output per phase. + A value of 100 representing a unity Power Factor (1.00). + Measured in hundredths." + ::= { xPDUSystemOutputPhaseEntry 7 } + +xPDUGroundCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Shows the current measured in the earth ground conductor. + Measured in tenths of Amps, or -1 if not available." + ::= { xPDUGroundMonitorPoint 1 } + +xPDUGroundCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER (0..50) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold above which a ground current over current + condition will be generated. Specified in tenths of Amps." + ::= { xPDUGroundMonitorPoint 2 } + +-- System Breakers + +xPDUSystemBreakerTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of system breaker entries." + ::= { xPDUSystemBreakers 1 } + +xPDUSystemBreakerTable OBJECT-TYPE + SYNTAX SEQUENCE OF XPDUSystemBreakerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of system breaker entries. + The number of entries is contained in the + xPDUSystemBreakerTableSize OID." + ::= { xPDUSystemBreakers 2 } + + xPDUSystemBreakerEntry OBJECT-TYPE + SYNTAX XPDUSystemBreakerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular system breaker." + INDEX { xPDUSystemBreakerTableIndex } + ::= { xPDUSystemBreakerTable 1 } + + XPDUSystemBreakerEntry ::= SEQUENCE { + xPDUSystemBreakerTableIndex INTEGER, + xPDUSystemBreakerDescription DisplayString, + xPDUSystemBreakerPosition INTEGER + } + + xPDUSystemBreakerTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of system breaker entries in the table." + ::= { xPDUSystemBreakerEntry 1 } + +xPDUSystemBreakerDescription OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..79)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A brief description of the system breakers." + ::= { xPDUSystemBreakerEntry 2 } + + xPDUSystemBreakerPosition OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2), + unknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether this breaker is open(1) or closed(2)." + ::= { xPDUSystemBreakerEntry 3 } + +-- Branch Breakers (Breaker Panel) + +xPDUNumOfBranchBreakers OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of branch breakers (panel positions) in the Panel. + returns 42 for a 1-panel or 84 for a 2-panel system." + ::= { xPDUBranchBreakers 1 } + +-- Branch Breakers Table + +xPDUBranchBreakerTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of branch breaker entries determined by the xPDUNumOfBranchBreakers OID." + ::= { xPDUBranchBreakers 2 } + +xPDUBranchBreakerTable OBJECT-TYPE + SYNTAX SEQUENCE OF XPDUBranchBreakerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of branch breaker table entries. The + number of entries is given by the value of xPDUBranchBreakerTableSize + The number of entries is contained in the xPDUBranchBreakerTableSize OID." + ::= { xPDUBranchBreakers 3 } + + xPDUBranchBreakerEntry OBJECT-TYPE + SYNTAX XPDUBranchBreakerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular branch breaker (panel position)." + INDEX { xPDUBranchBreakerTableIndex } + ::= { xPDUBranchBreakerTable 1 } + + XPDUBranchBreakerEntry ::= SEQUENCE { + xPDUBranchBreakerTableIndex INTEGER, + xPDUBranchBreakerRating INTEGER, + xPDUBranchBreakerRDPFeed INTEGER, + xPDUBranchBreakerTieIndicator INTEGER, + xPDUBranchBreakerCurrent INTEGER, + xPDUBranchBreakerOverCurrentThreshold INTEGER, + xPDUBranchBreakerUnderCurrentThreshold INTEGER, + xPDUBranchBreakerMaxCurrentThreshold INTEGER, + xPDUBranchBreakerMinCurrentThreshold INTEGER, + xPDUBranchBreakerName DisplayString, + xPDUBranchBreakerLocation DisplayString + } + + xPDUBranchBreakerTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of branch breaker entries in the table." + ::= { xPDUBranchBreakerEntry 1 } + + xPDUBranchBreakerRating OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Indicates current rating of this breaker. + 0=Breaker is not present. + 1=Earth leakage connection. + 2=Neutral connection. + A value greater than 2 indicates breaker current rating in Amps. + A value above 60 Amp will signify a remote feed. + The xPDUBranchBreakerRDPFeed OID will indicate which breakers are + configured as a remote drop. + Note: When setting branch circuit thresholds/ratings for an entry, + all positions tied (see the xPDUBranchBreakerTieIndicator OID) + to this entry will inherit the new threshold/rating." + ::= { xPDUBranchBreakerEntry 2 } + + xPDUBranchBreakerRDPFeed OBJECT-TYPE + SYNTAX INTEGER { + remoteDistribution (1), + noRemoteDistribution (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates that a breaker position is feeding a remote + distribution panel." + ::= { xPDUBranchBreakerEntry 3 } + + xPDUBranchBreakerTieIndicator OBJECT-TYPE + SYNTAX INTEGER { + breakerUnTied (1), + breakerTied (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Indicates whether or not the breaker in this position + is logically associated with the breaker immediately below it. + This setting is used grouping the breakers feeding + a multi-pole branch circuit. + Note: When setting an entry's branch breaker tie indicator to breakerTied, + all the positions that are tied to this breaker will take on the rating + and thresholds for this entry of the table." + ::= { xPDUBranchBreakerEntry 4 } + + xPDUBranchBreakerCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the branch current in tenths of Amps or -1 when not available." + ::= { xPDUBranchBreakerEntry 5 } + + xPDUBranchBreakerOverCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold above which a branch circuit high current + condition will be generated. + Specified as a percent of the branch breaker rating. + A value of zero indicates that the threshold is disabled. + Note: When setting branch circuit thresholds/ratings for an entry, + all positions tied (see the xPDUBranchBreakerTieIndicator OID) + to this entry will inherit the new threshold/rating." + ::= { xPDUBranchBreakerEntry 6 } + + xPDUBranchBreakerUnderCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold below which a branch circuit low current + condition will be generated. + Specified as a percent of the branch breaker rating. + A value of zero indicates that the threshold is disabled. + Note: When setting branch circuit thresholds/ratings for an entry, + all positions tied (see the xPDUBranchBreakerTieIndicator OID) + to this entry will inherit the new threshold/rating." + ::= { xPDUBranchBreakerEntry 7 } + + xPDUBranchBreakerMaxCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold above which a branch circuit maximum current + condition will be generated. + Specified as a percent of the branch breaker rating. + A value of zero indicates that the threshold is disabled. + Note: When setting branch circuit thresholds/ratings for an entry, + all positions tied (see the xPDUBranchBreakerTieIndicator OID) + to this entry will inherit the new threshold/rating." + ::= { xPDUBranchBreakerEntry 8 } + + xPDUBranchBreakerMinCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold below which a branch circuit minimum current + condition will be generated. + Specified as a percent of the branch breaker rating. + A value of zero indicates that the threshold is disabled. + Note: When setting branch circuit thresholds/ratings for an entry, + all positions tied (see the xPDUBranchBreakerTieIndicator OID) + to this entry will inherit the new threshold/rating." + ::= { xPDUBranchBreakerEntry 9 } + + xPDUBranchBreakerName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The description of the purpose/use of the breaker." + ::= { xPDUBranchBreakerEntry 10 } + + xPDUBranchBreakerLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The description of the location of the breaker." + ::= { xPDUBranchBreakerEntry 11 } + + +-- the xPDUInputContacts group + +xPDUInputContactNumContacts OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of contacts supported by the PDU." + ::= { xPDUInputContacts 1 } + +xPDUInputContactTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of input contact entries." + ::= { xPDUInputContacts 2 } + +xPDUInputContactTable OBJECT-TYPE + SYNTAX SEQUENCE OF XPDUInputContactEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of contacts supported by the PDU. + The number of entries is contained in the + xPDUInputContactTableSize OID." + ::= { xPDUInputContacts 3 } + +xPDUInputContactEntry OBJECT-TYPE + SYNTAX XPDUInputContactEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A contact entry containing information for a given contact." + INDEX { xPDUInputContactNumber } + ::= { xPDUInputContactTable 1 } + +XPDUInputContactEntry ::= + SEQUENCE { + xPDUInputContactNumber INTEGER, + xPDUInputContactName DisplayString, + xPDUInputContactNormalState INTEGER, + xPDUInputContactCurrentState INTEGER + } + +xPDUInputContactNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index identifying the contact on the PDU." + ::= { xPDUInputContactEntry 1 } + +xPDUInputContactName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The description of the purpose/use of the contact." + ::= { xPDUInputContactEntry 2 } + +xPDUInputContactNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal operating position of the contact." + ::= { xPDUInputContactEntry 3 } + +xPDUInputContactCurrentState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2), + unknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This value indicates the current state of the contact." + ::= { xPDUInputContactEntry 4 } + +-- the xPDUOutputRelays group + +xPDUOutputRelaysNumRelays OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of output relays supported by the PDU." + ::= { xPDUOutputRelays 1 } + +xPDUOutputRelaysTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of output relay entries." + ::= { xPDUOutputRelays 2 } + +xPDUOutputRelayTable OBJECT-TYPE + SYNTAX SEQUENCE OF XPDUOutputRelayEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of output relays supported by the PDU. + The number of entries is contained in the + xPDUOutputRelayTableSize OID." + ::= { xPDUOutputRelays 3 } + +xPDUOutputRelayEntry OBJECT-TYPE + SYNTAX XPDUOutputRelayEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A output relay entry containing information for a given contact." + INDEX { xPDUOutputRelayNumber } + ::= { xPDUOutputRelayTable 1 } + +XPDUOutputRelayEntry ::= + SEQUENCE { + xPDUOutputRelayNumber INTEGER, + xPDUOutputRelayName DisplayString, + xPDUOutputRelayNormalState INTEGER, + xPDUOutputRelayCurrentState INTEGER + } + +xPDUOutputRelayNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index identifying the output relay on the PDU." + ::= { xPDUOutputRelayEntry 1 } + +xPDUOutputRelayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The description of the purpose/use of the output relay." + ::= { xPDUOutputRelayEntry 2 } + +xPDUOutputRelayNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal operating position of the output relay." + ::= { xPDUOutputRelayEntry 3 } + +xPDUOutputRelayCurrentState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2), + unknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This value indicates the current state of the output relay." + ::= { xPDUOutputRelayEntry 4 } + +-- the xPDUMiscGroup + +xPDUEPOMode OBJECT-TYPE + SYNTAX INTEGER { + armed (1), + disarmed (2), + unknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether the EPO System is armed(1) or disarmed(2)." + ::= { xPDUMiscGroup 1 } + +xPDUTransformTempStatus OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + overtemp (2), + noTransformerPresent (3), + unknown (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates if the PDU's isolation transformer is over temperature." + ::= { xPDUMiscGroup 2 } + +xPDUCoolingFanStatus OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + failed (2), + noCoolingFansPresent (3), + unknown (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates if one or more of the PDU's cooling fans have failed." + ::= { xPDUMiscGroup 3 } + +-- The xATSIdent group + +xATSIdentProductName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the transfer switch unit." + ::= { xATSIdent 1 } + +xATSIdentHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the transfer switch. + This value is set at the factory." + ::= { xATSIdent 2 } + +xATSIdentFirmwareAppRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ID string identifying the application firmware revision of the transfer switch." + ::= { xATSIdent 3 } + +xATSIdentFirmwareAppOSRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ID string identifying the application operating system firmware revision of the transfer switch." + ::= { xATSIdent 4 } + +xATSIdentFirmwareControllerRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ID string identifying the transfer switch controller firmware revision." + ::= { xATSIdent 5 } + +xATSIdentDateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date when the transfer switch was manufactured in mm/dd/yyyy format. + This value is set at the factory." + ::= { xATSIdent 6 } + +xATSIdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the model number of the transfer switch. + This value is set at the factory." + ::= { xATSIdent 7 } + +xATSIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the serial number of the transfer switch. + This value is set at the factory." + ::= { xATSIdent 8 } + +-- The xATSDevice group + +xATSDeviceServiceType OBJECT-TYPE + SYNTAX INTEGER { + threeWire (1), + fourWire (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of utility input to the transfer switch. + Either 3 wires (delta), or 4 wires (wye)." + ::= { xATSDevice 1 } + +xATSDeviceNominalVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal line-to-neutral system voltage. + Measured in Volts, line-to-line for a 3-wire service or + line-to-neutral for a 4-wire service. -1 if not available." + ::= { xATSDevice 2 } + +xATSDeviceNominalFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal system frequency. Measured in tenths of Hertz. + -1 if not available." + ::= { xATSDevice 3 } + +xATSDeviceTransferSwitchRating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The rating of the transfer switch. + Measured in Amps." + ::= { xATSDevice 4 } + +xATSDeviceDCBackUpPresent OBJECT-TYPE + SYNTAX INTEGER{ + yes (1), + no (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Indicates if a DC backup is present or not." + ::= { xATSDevice 5 } + +-- The xATS Switch Status group + +xATSSwitchStatusSelectedSource OBJECT-TYPE + SYNTAX INTEGER{ + none (1), + source1 (2), + source2 (3), + fault (4), + unknown (5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The source which is currently selected, i.e. supplying power to the load." + ::= { xATSSwitchStatus 1 } + +xATSSwitchStatusOperationalMode OBJECT-TYPE + SYNTAX INTEGER{ + automatic (1), + notInAutoAbnormal (2), + notInAuto (3), + unknown (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current operating mode of the transfer switch. When the ATS is in + automatic mode, generator starting and ATS transferring is all done automatically + as needed based on the state of source 1. Automatic operation is halted when the + ATS is in either of the notInAuto modes. + A mode of notInAuto indicates that the automatic operation switch is in the + disabled position, as indicated by the xATSSwitchStatusAutomaticOperationSwitch OID. + The notInAutoAbnormal condition indicates that an abnormal + condition has caused the transfer switch to halt automatic operation. + In this case, traps can indicate the exact problem. In the case of + notInAutoAbnormal, refer to the operation manual for details + on how debug the condition and restore automatic operation." + ::= { xATSSwitchStatus 2 } + +xATSSwitchStatusAutomaticOperationSwitch OBJECT-TYPE + SYNTAX INTEGER{ + disabled (1), + enabled (2), + unknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The position of the automatic operation switch on the front of the transfer switch." + ::= { xATSSwitchStatus 3 } + +xATSSwitchStatusEngineStartSignal OBJECT-TYPE + SYNTAX INTEGER{ + run (1), + stop (2), + unknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The position of the Start/Stop contact which signals the generator + engine to start/run. When the ATS is in automatic mode, + generator starting/stopping is under ATS control." + ::= { xATSSwitchStatus 4 } + +-- The xATS Switch Setting group + +xATSSwitchSettingsLowVoltageTransferPoint OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The lowest acceptable voltage condition at source 1. + When any phase of source 1 is lower than this voltage, + source quality is considered bad and the generator run signal + is asserted to begin generator operation. + Specified in volts, line-to-line for a 3-wire service or + line-to-neutral for a 4-wire service. + -1 if not available." + ::= { xATSSwitchSettings 1 } + +xATSSwitchSettingsHighVoltageTransferPoint OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The highest acceptable voltage condition at source 1. + When any phase of source 1 is greater than this voltage, + source quality is considered bad and the generator run signal + is asserted to begin generator operation. + Specified in volts, line-to-line for a 3-wire service or + line-to-neutral for a 4-wire service. + -1 if not available." + ::= { xATSSwitchSettings 2 } + +xATSSwitchSettingsMaxFrequencyDeviation OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum acceptable frequency deviation condition from nominal at source 1. + When source 1 frequency is outside the specified range, + source quality is considered bad and the generator run signal + is asserted to begin generator operation. + Specified in tenths of Hertz above or below nominal. + A value of zero indicates that frequency is ignored when + determining source quality. + -1 if not available." + ::= { xATSSwitchSettings 3 } + +xATSSwitchSettingsMinPhaseBalance OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The minimum required phase balance at source 1. + When the percentage difference between the minimum and maximum + phase voltage measurements at source 1 is greater than this value, + source quality is considered bad and the generator run signal + is asserted to begin generator operation. + Specified as a percentage. A value of zero indicates that phase balance + is ignored when determining source quality. -1 if not available." + ::= { xATSSwitchSettings 4 } + +xATSSwitchSettingsNominalRotation OBJECT-TYPE + SYNTAX INTEGER{ + abc (1), + cba (2), + any (3), + unknown (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The nominal phase rotation (or phase sequence) required by the load. + For certain types of equipment, such as rotating machinery, phase rotation + is critical for proper operation as it determines the direction which motors + will rotate (clockwise or counterclockwise). + Source quality will be seen as bad if the rotation measured at that + ATS input does not match this setting. + If this setting is set to any, phase rotation is ignored." + ::= { xATSSwitchSettings 5 } + +xATSSwitchSettingsAllowClosedTransfer OBJECT-TYPE + SYNTAX INTEGER{ + yes (1), + no (2), + unknown (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This setting enables seamless (closed) transfers between sources. + When possible, both source 1 and source 2 are closed to the output + for a brief time. If closed transfer is not possible within the amount + of time specified by the xATSSwitchSettingsMaxSyncTime OID, + an open transfer will be executed." + ::= { xATSSwitchSettings 6 } + +xATSSwitchSettingsMaxSyncTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When attempting/seeking to perform a closed transfer, this setting defines + the maximum time allowed before the transfer switch will give up and perform + an open transfer. Specified in seconds. + -1 if not available." + ::= { xATSSwitchSettings 7 } + +xATSSwitchSettingsNeutralTransferTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This setting defines how long both source 1 and source 2 will be + disconnected from the output, during an open transfer. + Specified in seconds. + -1 if not available." + ::= { xATSSwitchSettings 8 } + +xATSSwitchSettingsClearLatchedAlarms OBJECT-TYPE + SYNTAX INTEGER{ + yes (1), + no (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Clears any latched alarm conditions." + ::= { xATSSwitchSettings 9 } + +xATSSwitchSettingsSetToFactoryDefaults OBJECT-TYPE + SYNTAX INTEGER{ + yes (1), + no (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sets all transfer switch settings to factory default values." + ::= { xATSSwitchSettings 10 } + + +-- The xATSSwitchTimers group + + xATSSwitchTimersTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of transfer switch timer entries." + ::= { xATSSwitchTimers 1 } + + xATSSwitchTimersTable OBJECT-TYPE + SYNTAX SEQUENCE OF XATSSwitchTimersEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of timers supported by ATS. + The number of entries is contained in the xATSSwitchTimersTableSize OID." + ::= { xATSSwitchTimers 2 } + + xATSSwitchTimersEntry OBJECT-TYPE + SYNTAX XATSSwitchTimersEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information about an individual ATS timer." + INDEX { xATSSwitchTimersIndex } + ::= { xATSSwitchTimersTable 1 } + + XATSSwitchTimersEntry ::= + SEQUENCE { + xATSSwitchTimersIndex INTEGER, + xATSSwitchTimersName DisplayString, + xATSSwitchTimersAbort INTEGER, + xATSSwitchTimersStatus INTEGER, + xATSSwitchTimersRemainingTime INTEGER, + xATSSwitchTimersDelaySetting INTEGER + } + +xATSSwitchTimersIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of timer entries in the table." + ::= { xATSSwitchTimersEntry 1 } + +xATSSwitchTimersName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Name of the individual timer.Refer to ATS operation manual, + or on-line help, for detailed descriptions of ATS timers." + ::= { xATSSwitchTimersEntry 2 } + +xATSSwitchTimersAbort OBJECT-TYPE + SYNTAX INTEGER{ + yes (1), + no (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This aborts the individual timer." + ::= { xATSSwitchTimersEntry 3 } + +xATSSwitchTimersStatus OBJECT-TYPE + SYNTAX INTEGER{ + inactive (1), + active (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the individual timer. Designates whether this timer + entry is currently running or inactive." + ::= { xATSSwitchTimersEntry 4 } + +xATSSwitchTimersRemainingTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The time remaining for this timer entry. + Specified in seconds." + ::= { xATSSwitchTimersEntry 5 } + +xATSSwitchTimersDelaySetting OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The delay settings associated with this timer entry. + When this timer entry is active, the timer value must exceed this setting + before the ATS behavior associated with this timer is executed. + Refer to ATS operation manual, or on-line help, for detailed + descriptions of ATS timers." + ::= { xATSSwitchTimersEntry 6 } + +-- The xATSSwitchBlockMap group + + xATSSwitchBlockMapTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of blocking map entries, or how many ATS actions can be blocked." + ::= { xATSSwitchBlockMap 1 } + + xATSSwitchBlockMapTable OBJECT-TYPE + SYNTAX SEQUENCE OF XATSSwitchBlockMapEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of blocking maps supported by the ATS. + The number of entries is contained in the xATSSwitchBlockMapTableSize OID." + ::= { xATSSwitchBlockMap 2 } + + xATSSwitchBlockMapEntry OBJECT-TYPE + SYNTAX XATSSwitchBlockMapEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information about a specific ATS blocking map." + INDEX { xATSSwitchBlockMapIndex } + ::= { xATSSwitchBlockMapTable 1 } + + XATSSwitchBlockMapEntry ::= + SEQUENCE { + xATSSwitchBlockMapIndex INTEGER, + xATSSwitchBlockMapName DisplayString, + xATSSwitchBlockMapStatus INTEGER, + xATSSwitchBlockMapSetting INTEGER + } + + xATSSwitchBlockMapIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of blocking map entries in the table." + ::= { xATSSwitchBlockMapEntry 1 } + + xATSSwitchBlockMapName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A string describing the ATS action to be blocked." + ::= { xATSSwitchBlockMapEntry 2 } + + xATSSwitchBlockMapStatus OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Represents the status of this blocking map entry, in bit-mapped format. + A non-zero value indicates that this entry's ATS action is currently being blocked. + The bit(s) set indicate which input(s) are causing the blocking (bit0, bit1, etc). + + bit 0 - Contact 1 + bit 1 - Contact 2 + bit 2 - Contact 3 + bit 3 - Contact 4." + ::= { xATSSwitchBlockMapEntry 3 } + + xATSSwitchBlockMapSetting OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This setting designates the inputs that block the ATS action + The mapping is specified as a bit-field, where each bit set indicates + the input that blocks the ATS action associated with the entry. + + bit 0 - Contact 1 + bit 1 - Contact 2 + bit 2 - Contact 3 + bit 3 - Contact 4." + ::= { xATSSwitchBlockMapEntry 4 } + +-- The xATSSwitchStatistics group + + xATSSwitchStatisticsTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of transfer switch statistics entries." + ::= { xATSSwitchStatistics 1 } + + xATSSwitchStatisticsTable OBJECT-TYPE + SYNTAX SEQUENCE OF XATSSwitchStatisticsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of statistics supported by ATS. + The number of entries is contained in the xATSSwitchStatisticsTableSize OID." + ::= { xATSSwitchStatistics 2 } + + xATSSwitchStatisticsEntry OBJECT-TYPE + SYNTAX XATSSwitchStatisticsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information about an individual ATS statistic." + INDEX { xATSSwitchStatisticsIndex } + ::= { xATSSwitchStatisticsTable 1 } + + XATSSwitchStatisticsEntry ::= + SEQUENCE { + xATSSwitchStatisticsIndex INTEGER, + xATSSwitchStatisticsName DisplayString, + xATSSwitchStatisticsValue DisplayString, + xATSSwitchStatisticsReset INTEGER + } + + xATSSwitchStatisticsIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of ATS statistics entries in the table." + ::= { xATSSwitchStatisticsEntry 1 } + + xATSSwitchStatisticsName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This is the name of the ATS statistic associated with this entry." + ::= { xATSSwitchStatisticsEntry 2 } + + xATSSwitchStatisticsValue OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This is the value of the ATS statistic associated with this entry." + ::= { xATSSwitchStatisticsEntry 3 } + + xATSSwitchStatisticsReset OBJECT-TYPE + SYNTAX INTEGER{ + yes (1), + no (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This will reset the individual ATS statistic associated with this entry." + ::= { xATSSwitchStatisticsEntry 4 } + +-- The xATS Source 1 group + +xATSSource1Name OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "String used to identify source 1." + ::= { xATSSource1 1 } + +xATSSource1Position OBJECT-TYPE + SYNTAX INTEGER{ + open (1), + closed (2), + tripped (3), + unknown (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current position of the switch at source 1." + ::= { xATSSource1 2 } + +xATSSource1Frequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frequency at source 1 in tenths of Hertz. + -1 if unavailable." + ::= { xATSSource1 3 } + +xATSSource1Quality OBJECT-TYPE + SYNTAX INTEGER{ + sourceGood (1), + lowVoltage (2), + highVoltage (3), + phaseImbalance (4), + freqOutOfRange (5), + badRotation (6), + unknown (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current line quality of source 1." + ::= { xATSSource1 4 } + +xATSSource1Rotation OBJECT-TYPE + SYNTAX INTEGER{ + abc (1), + cba (2), + unknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The phase rotation measured at the source 1 input of the ATS. + The sequence is a reference to the order in which the three phases + pass the zero-crossing boundary in time." + ::= { xATSSource1 5 } + +xATSSource1TableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of input voltage entries at the source 1 input of the ATS." + ::= { xATSSource1 6 } + + xATSSource1PhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF XATSSource1PhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of voltage table entries for source 1. The number of + entries are the phase entries. The number of entries is contained in the + xATSSource1TableSize OID." + ::= { xATSSource1 7 } + + xATSSource1PhaseEntry OBJECT-TYPE + SYNTAX XATSSource1PhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular input voltage phase at the source 1 input of the ATS." + INDEX { xATSSource1Index } + ::= { xATSSource1PhaseTable 1 } + + XATSSource1PhaseEntry ::= SEQUENCE { + xATSSource1Index INTEGER, + xATSSource1VoltageLtoL INTEGER, + xATSSource1VoltageLtoN INTEGER + } + + xATSSource1Index OBJECT-TYPE + SYNTAX INTEGER{ + phase1(1), + phase2(2), + phase3(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of each phase utilized at source 1." + ::= { xATSSource1PhaseEntry 1 } + + xATSSource1VoltageLtoL OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Source 1 line-to-line input voltage. + Measured in tenths of Volts." + ::= { xATSSource1PhaseEntry 2 } + + xATSSource1VoltageLtoN OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Source 1 line-to-neutral input voltage. + Measured in tenths of Volts. -1 for a 3-wire service type." + ::= { xATSSource1PhaseEntry 3 } + +-- The xATS Source 2 group + +xATSSource2Name OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "String used to identify source 2." + ::= { xATSSource2 1 } + +xATSSource2Position OBJECT-TYPE + SYNTAX INTEGER{ + open (1), + closed (2), + tripped (3), + unknown (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current position of the switch at source 2." + ::= { xATSSource2 2 } + +xATSSource2Frequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frequency at source 2 in tenths of Hertz. + -1 if not available." + ::= { xATSSource2 3 } + +xATSSource2Quality OBJECT-TYPE + SYNTAX INTEGER{ + sourceGood (1), + lowVoltage (2), + highVoltage (3), + phaseImbalance (4), + freqOutOfRange (5), + badRotation (6), + unknown (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current line quality of source 2." + ::= { xATSSource2 4 } + +xATSSource2Rotation OBJECT-TYPE + SYNTAX INTEGER{ + abc (1), + cba (2), + unknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The phase rotation measured at the source 2 input of the ATS. + -1 if not available." + ::= { xATSSource2 5 } + +xATSSource2TableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of input voltage entries at the source 2 input of the ATS." + ::= { xATSSource2 6 } + + xATSSource2PhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF XATSSource2PhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of voltage table entries for the source 2. The number of + entries are the phase entries. The number of entries is contained in the + xATSSource2TableSize OID." + ::= { xATSSource2 7 } + + xATSSource2PhaseEntry OBJECT-TYPE + SYNTAX XATSSource2PhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular input voltage phase at the source 2 input of the ATS." + INDEX { xATSSource2Index } + ::= { xATSSource2PhaseTable 1 } + + XATSSource2PhaseEntry ::= SEQUENCE { + xATSSource2Index INTEGER, + xATSSource2VoltageLtoL INTEGER, + xATSSource2VoltageLtoN INTEGER + } + + xATSSource2Index OBJECT-TYPE + SYNTAX INTEGER{ + phase1(1), + phase2(2), + phase3(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of each phase utilized at the source 2." + ::= { xATSSource2PhaseEntry 1 } + + xATSSource2VoltageLtoL OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Source 2 line-to-line input voltage. + Measured in tenths of Volts." + ::= { xATSSource2PhaseEntry 2 } + + xATSSource2VoltageLtoN OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Source 2 line-to-neutral input voltage. + Measured in tenths of Volts. -1 for a 3-wire service type." + ::= { xATSSource2PhaseEntry 3 } + +-- The xATSSystemOutput + +xATSSystemOutputFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system output frequency in tenths of Hertz." + ::= { xATSSystemOutput 1 } + +xATSSystemOutputTotalPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Shows the total system output power in tenths of kW." + ::= { xATSSystemOutput 2 } + +xATSSystemOutputTotalApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Shows the total system output power in tenths of kVA." + ::= { xATSSystemOutput 3 } + +xATSSystemOutputTotalPowerFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the total power factor of the system output. + A value of 100 representing a unity power factor (1.00) + Specified in hundredths." + ::= { xATSSystemOutput 4 } + +xATSSystemOutputFrequencyTolerance OBJECT-TYPE + SYNTAX INTEGER{ + freqToleranceOff (1), + freqTolerancePointTwo (2), + freqTolerancePointFive (3), + freqToleranceOne (4), + freqToleranceOnePointFive (5), + freqToleranceTwo (6), + freqToleranceThree (7), + freqToleranceFour (8), + freqToleranceFive (9), + freqToleranceNine (10) + + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Shows the panel output frequency tolerance in +/- Hertz." + ::= { xATSSystemOutput 5 } + +xATSSystemOutputOverVoltThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold above which an output over voltage condition will be generated. + Specified as tenths of percent deviation from nominal. + A value of zero indicates that the threshold is disabled." + ::= { xATSSystemOutput 6 } + +xATSSystemOutputUnderVoltThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold below which an output under voltage condition will be generated. + Specified as tenths of percent deviation from nominal. + A value of zero indicates that the threshold is disabled." + ::= { xATSSystemOutput 7 } + +xATSSystemOutputOverCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold above which an over current condition will be generated. + Specified as a percent of the transfer switch rating (xATSDeviceTransferSwitchRating OID). + A value of zero indicates that the threshold is disabled." + ::= { xATSSystemOutput 8 } + +xATSSystemOutputUnderCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold below which an under current condition will be generated. + Specified as a percent of the transfer switch rating (xATSDeviceTransferSwitchRating OID). + A value of zero indicates that the threshold is disabled." + ::= { xATSSystemOutput 9 } + +xATSSystemOutputAlarmDelayThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Delay the generation of an output alarm. + Specified in seconds." + ::= { xATSSystemOutput 10 } + +xATSSystemOutputTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of system output phase entries." + ::= { xATSSystemOutput 11 } + +xATSSystemOutputPhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF XATSSystemOutputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of system output table entries. + The number of entries is contained in the xATSSystemOutputTableSize OID." + ::= { xATSSystemOutput 12 } + + xATSSystemOutputPhaseEntry OBJECT-TYPE + SYNTAX XATSSystemOutputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular system output phase." + INDEX { xATSSystemOutputPhaseIndex } + ::= { xATSSystemOutputPhaseTable 1 } + + XATSSystemOutputPhaseEntry ::= SEQUENCE { + xATSSystemOutputPhaseIndex INTEGER, + xATSSystemOutputVoltageLtoL INTEGER, + xATSSystemOutputVoltageLtoN INTEGER, + xATSSystemOutputPhaseCurrent INTEGER, + xATSSystemOutputPower INTEGER, + xATSSystemOutputApparentPower INTEGER, + xATSSystemOutputPowerFactor INTEGER + } + + xATSSystemOutputPhaseIndex OBJECT-TYPE + SYNTAX INTEGER{ + phase1(1), + phase2(2), + phase3(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of each system output phase utilized in this device." + ::= { xATSSystemOutputPhaseEntry 1 } + + xATSSystemOutputVoltageLtoL OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Line-to-line system output voltage available at the circuit panel. + Measured in tenths of Volts. -1 if not available." + ::= { xATSSystemOutputPhaseEntry 2 } + + xATSSystemOutputVoltageLtoN OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Line-to-neutral system output voltage available at the circuit panel. + Measured in tenths of Volts. -1 for a 3-wire service type or if not available." + ::= { xATSSystemOutputPhaseEntry 3 } + + xATSSystemOutputPhaseCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "System load current per phase. Measured in Amps. + -1 if not available." + ::= { xATSSystemOutputPhaseEntry 4 } + + xATSSystemOutputPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "System output power per phase. Measured in tenths of kW." + ::= { xATSSystemOutputPhaseEntry 5 } + + xATSSystemOutputApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "system output power per phase. Measured in tenths of kVA." + ::= { xATSSystemOutputPhaseEntry 6 } + + xATSSystemOutputPowerFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "indicates the power factor of the system output per phase. + A value of 100 representing a unity power factor (1.00). + Measured in hundredths." + ::= { xATSSystemOutputPhaseEntry 7 } + +-- xATS TestingStatus group + +xATSTestingStatusSelectTestProcess OBJECT-TYPE + SYNTAX INTEGER { + engineStartTest (1), + systemLoadTest (2), + generatorHoldTest (3), + cancelTest (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Type of tests that can be selected when no test has been scheduled. + engineStartTest and systemLoadTest may be selected when no tests + are running. Tests that are selected may be canceled manually." + ::= { xATSTestingStatus 1 } + +xATSTestingStatusTestStatus OBJECT-TYPE + SYNTAX INTEGER { + noTestInProcess (1), + testPending (2), + startingEngine (3), + engineWarmingUp (4), + awaitingTransferToS2 (5), + testingWithLoad (6), + awaitingRetransferToS1 (7), + testingWithoutLoad (8), + stoppingEngine (9), + holdingOnGenerator (10) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The present system test status/state." + ::= { xATSTestingStatus 2 } + +xATSTestingStatusProfileWarmupTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of time that the generator will warm up during a test. + This is portion of the test when the xATSTestingStatusTestStatus + OID returns the value engineWarmingUp. + Specified in seconds." + ::= { xATSTestingStatus 3 } + +xATSTestingStatusProfileLoadedTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of time that ATS will apply the system load to the generator + during a system load test. + This is portion of the test when the xATSTestingStatusTestStatus + OID returns the value testingWithLoad. + Specified in minutes." + ::= { xATSTestingStatus 4 } + +xATSTestingStatusProfileUnloadedTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of time that the generator will run following the warm up + portion of a start test, or the loaded portion of a load test. + This is portion of the test when the xATSTestingStatusTestStatus + OID returns the value testingWithoutLoad. + Specified in seconds." + ::= { xATSTestingStatus 5 } + +-- xATS TestingResults group + +xATSTestingResultsLastDateOfTest OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Date of the last test that was performed, either scheduled or manual. + Test results are available in the xATSTestingResultsLastResult OID. + Specified in the dd/mm/yyyy format, or 'none' if not available." + ::= { xATSTestingResults 1 } + +xATSTestingResultsLastResult OBJECT-TYPE + SYNTAX INTEGER { + noResultsAvailable (1), + startTestPassed (2), + loadTestPassed (3), + startSignalFailure (4), + failedGenNotInAuto (5), + failedGenEmerStop (6), + failedGenShutdown (7), + failedGenDidNotStart (8), + failedS2NeverGood (9), + genFailedDuringWarmup (10), + failureOnXferToS1 (11), + genFailedLoaded (12), + failureOnRexferToS2 (13), + failedOnCooldown (14), + genFailedToStop (15), + failedAtsInternalFault (16), + failedAtsNotInAuto (17), + canceledManualTest (18), + canceledScheduledTest (19) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The result of the last ATS/generator system test." + ::= { xATSTestingResults 2 } + +xATSTestingResultsTestLastTestTime OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Time of day at which the last test was performed, either scheduled or manual. + Test results are available in the xATSTestingResultsLastResult OID. + Specified in the hh:mm:ss format, or 'none' if not available." + ::= { xATSTestingResults 3 } + +xATSTestingResultsLastCrankDuration OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The time spent cranking the generator before it started during the last test. + Specified in seconds, or -1 if not available." + ::= { xATSTestingResults 4 } + +xATSTestingResultsLastWarmupDuration OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The time spent in the engineWarmingUp state during the last system test. + Specified in seconds, or -1 if not available." + ::= { xATSTestingResults 5 } + +xATSTestingResultsLastLoadedDuration OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The time spent in the testingWithLoad state during the last system test. + Specified in seconds, or -1 if not available." + ::= { xATSTestingResults 6 } + +xATSTestingResultsLastUnloadedDuration OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The time spent in the testingWithoutLoad state during the last system test. + Specified in seconds, or -1 if not available." + ::= { xATSTestingResults 7 } + +-- xATS TestingSchedule group + +xATSTestingScheduleFrequency OBJECT-TYPE + SYNTAX INTEGER { + never (1), + daily (2), + weekly (3), + monthly (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The frequency of running scheduled tests." + ::= { xATSTestingSchedule 1 } + +xATSTestingScheduleTestDay OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The desired day for the scheduled test. This object applies only + when the xATSTestingScheduleFrequency OID is set to weekly or monthly. + For weekly test frequency, the string is the day the test will be run. + For monthly test frequency, the string indicates the day, + and the instance within the month. + For example, for monthly frequency: 2nd Sunday, 3rd Monday, 4th Tuesday, + for weekly frequency: Sunday, Monday, Tuesday." + ::= { xATSTestingSchedule 2 } + +xATSTestingScheduleTestTime OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The time of day that the scheduled test will occur. + Specified in the format hh:mm." + ::= { xATSTestingSchedule 3 } + +xATSTestingScheduleTestWithLoadInterval OBJECT-TYPE + SYNTAX INTEGER { + applyLoadEveryTest (1), + neverApplyLoad (2), + applyLoadMonthly (3), + applyLoadMonthlyDetailed (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This setting specifies which system tests should include applying the + load to the generator. The applyLoadMonthlyDetailed entry + in the list will apply load once, for each month represented in the + xATSTestingScheduleTestWithLoadSelectMonth OID." + ::= { xATSTestingSchedule 4 } + +xATSTestingScheduleTestWithLoadSelectMonth OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The detailed selection for testing with load on a month-by-month basis. + This object is applicable when the xATSTestingScheduleTestWithLoadInterval + is set to applyLoadMonthlyDetailed. Otherwise this selection will be ignored. + Format for this string is a comma-separated entry of months. + For example: Jan,Mar,Dec. + The string will return 'No Months Scheduled' if no months have been selected." + ::= { xATSTestingSchedule 5 } + +xATSTestingScheduleNextTestDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date of the next scheduled test, in the format dd-mmm-yyyy." + ::= { xATSTestingSchedule 6 } + +-- xATSTestingSimulatePowerFail group + +xATSTestingSimulatePowerFailTest OBJECT-TYPE + SYNTAX INTEGER{ + cancelSimulation (1), + fiveSecondsSimulation (2), + tenSecondsSimulation (3), + thirtySecondsSimulation (4), + oneMinuteSimulation (5), + threeMinutesSimulation (6), + fiveMinutesSimulation (7), + tenMinutesSimulation (8) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This object executes a simulated power failure for the duration indicated. + Simulation can be aborted by selecting cancelSimulation." + ::= { xATSTestingSimulatePowerFail 1 } + +xATSTestingSimulatePowerFailTimeRemaining OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the time remaining in seconds, for a simulated power failure. + a value of zero indicates that simulated power failure is not active." + ::= { xATSTestingSimulatePowerFail 2 } + +-- The xATS Input Contact group + +xATSInputContactNumContacts OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of contacts supported by the ATS." + ::= { xATSInputContacts 1 } + +xATSInputContactTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of input contact entries." + ::= { xATSInputContacts 2 } + +xATSInputContactTable OBJECT-TYPE + SYNTAX SEQUENCE OF XATSInputContactEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of contacts supported by the ATS. + The number of entries is contained in the + xATSInputContactTableSize OID." + ::= { xATSInputContacts 3 } + + xATSInputContactEntry OBJECT-TYPE + SYNTAX XATSInputContactEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A contact entry containing information for a given contact." + INDEX { xATSInputContactNumber } + ::= { xATSInputContactTable 1 } + + XATSInputContactEntry ::= + SEQUENCE { + xATSInputContactNumber INTEGER, + xATSInputContactName DisplayString, + xATSInputContactNormalState INTEGER, + xATSInputContactCurrentState INTEGER + } + + xATSInputContactNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index identifying the contact on the ATS." + ::= { xATSInputContactEntry 1 } + + xATSInputContactName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The description of the purpose/use of the contact." + ::= { xATSInputContactEntry 2 } + + xATSInputContactNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal operating position of the contact." + ::= { xATSInputContactEntry 3 } + + xATSInputContactCurrentState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This value indicates the current state of the contact." + ::= { xATSInputContactEntry 4 } + +-- the xATS OutputRelays group + + xATSOutputRelayNumRelays OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of output relays supported by the ATS." + ::= { xATSOutputRelays 1 } + + xATSOutputRelayTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of output relay entries." + ::= { xATSOutputRelays 2 } + + xATSOutputRelayTable OBJECT-TYPE + SYNTAX SEQUENCE OF XATSOutputRelayEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of output relays supported by the ATS. + The number of entries is contained in the + xATSOutputRelayTableSize OID." + ::= { xATSOutputRelays 3 } + + xATSOutputRelayEntry OBJECT-TYPE + SYNTAX XATSOutputRelayEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A output relay entry containing information for a given contact." + INDEX { xATSOutputRelayNumber } + ::= { xATSOutputRelayTable 1 } + + XATSOutputRelayEntry ::= + SEQUENCE { + xATSOutputRelayNumber INTEGER, + xATSOutputRelayName DisplayString, + xATSOutputRelayNormalState INTEGER, + xATSOutputRelayCurrentState INTEGER + } + + xATSOutputRelayNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index identifying the output relay on the ATS." + ::= { xATSOutputRelayEntry 1 } + + xATSOutputRelayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The description of the purpose/use of the output relay." + ::= { xATSOutputRelayEntry 2 } + + xATSOutputRelayNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal operating position of the output relay." + ::= { xATSOutputRelayEntry 3 } + + xATSOutputRelayCurrentState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This value indicates the current state of the output relay." + ::= { xATSOutputRelayEntry 4 } + +-- The xATS Generator Ident group + +xATSGeneratorIdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the model number of the generator. + This value is set at the factory." + ::= { xATSGeneratorIdent 1 } + +xATSGeneratorIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the serial number of the generator. + This value is set at the factory." + ::= { xATSGeneratorIdent 2 } + +xATSGeneratorIdentDateofManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying when the generator was manufactured in mm/dd/yyyy format. + This value is set at the factory." + ::= { xATSGeneratorIdent 3 } + +xATSGeneratorIdentVoltageConfiguration OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage for which the generator's alternator is designed. + Specified in Volts line-to-line." + ::= { xATSGeneratorIdent 4 } + +xATSGeneratorIdentMaxPowerRating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The max power rating of the generator. Specified in kW." + ::= { xATSGeneratorIdent 5 } + +xATSGeneratorIdentAlternatorFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frequency for which the generator's alternator is designed. + Specified in Hertz." + ::= { xATSGeneratorIdent 6 } + +-- The xATS Generator Status group + +xATSGeneratorStatusGeneratorName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name or label for the generator connected to the source 2 of the ATS." + ::= { xATSGeneratorStatus 1 } + +xATSGeneratorStatusOperational OBJECT-TYPE + SYNTAX INTEGER{ + nocomm (1), + off (2), + ready (3), + starting (4), + idle (5), + running (6), + normalStop (7), + emergencyStop (8), + notInAuto (9), + shutdown (10), + unknown (11) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The operational status of the generator. unavailable when unrecognized status is received." + ::= { xATSGeneratorStatus 2 } + +xATSGeneratorStatusModeSwitchPosition OBJECT-TYPE + SYNTAX INTEGER{ + off (1), + manual (2), + automatic (3), + unknown (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The position of the generator's auto-mode switch. + In automatic mode, the generator is started and stopped via the + remote start contact, which has state indicated in the + xATSGeneratorStatusRemoteStart OID. + In manual mode generator start/stop control is via local command only. + Off prevents the generator from running." + ::= { xATSGeneratorStatus 3 } + +xATSGeneratorStatusRemoteStart OBJECT-TYPE + SYNTAX INTEGER{ + stop (1), + run (2), + unknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the generator's remote start contact, which is + provided as an output from the transfer switch to start/stop the + generator when in automatic mode." + ::= { xATSGeneratorStatus 4 } + +-- The xATS Generator Advanced Status group + +xATSGeneratorAdvStatusBatteryVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage of the generator's starting battery. + Measured in tenths of VDC, or -1 if not available." + ::= { xATSGeneratorAdvStatus 1 } + +xATSGeneratorAdvStatusOilPressure OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The generator's engine oil pressure. + Measured in tenths of Psi or kPa, based on the + value of the xATSGeneratorSettingsMetricUnit OID, + or -1 if not available." + ::= { xATSGeneratorAdvStatus 2 } + +xATSGeneratorAdvStatusCoolantTemperature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Current coolant temperature in the generator. + Measured in degrees Celsius or Fahrenheit, based on the + value of the xATSGeneratorSettingsMetricUnit OID, + or -1 if not available." + ::= { xATSGeneratorAdvStatus 3 } + +xATSGeneratorAdvStatusEngineRPM OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Current engine speed of the generator. + Measured in RPM, or -1 if not available." + ::= { xATSGeneratorAdvStatus 4 } + +xATSGeneratorAdvStatusOilLevel OBJECT-TYPE + SYNTAX INTEGER{ + ok (1), + low (2), + unknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates adequate oil level in the generator." + ::= { xATSGeneratorAdvStatus 5 } + +xATSGeneratorAdvStatusCoolantLevel OBJECT-TYPE + SYNTAX INTEGER{ + ok (1), + low (2), + unknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates adequate coolant level in the generator." + ::= { xATSGeneratorAdvStatus 6 } + +-- The xATS Generator Output group + +xATSGeneratorOutputFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output frequency of the generator. + Measured in tenths of Hertz, or -1 if not available." + ::= { xATSGeneratorOutput 1 } + +xATSGeneratorOutputTotalPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total output power of the generator. + Measured in tenths of tenths of kW, or -1 if not available." + ::= { xATSGeneratorOutput 2 } + +xATSGeneratorOutputTotalApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total output power of the generator. + Measured in tenths of kVA, or -1 if not available." + ::= { xATSGeneratorOutput 3 } + +xATSGeneratorOutputTotalPowerFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the total load power factor of the generator. + A value of 100 representing a unity power factor (1.00), + or -1 when if not available." + ::= { xATSGeneratorOutput 4 } + +xATSGeneratorOutputTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of generator output phase entries." + ::= { xATSGeneratorOutput 5 } + + xATSGeneratorOutputPhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF XATSGeneratorOutputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of generator output table entries. + The number of entries is contained in the xATSGeneratorOutputTableSize OID." + ::= { xATSGeneratorOutput 6 } + + xATSGeneratorOutputPhaseEntry OBJECT-TYPE + SYNTAX XATSGeneratorOutputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular generator output phase." + INDEX { xATSGeneratorOutputPhaseIndex } + ::= { xATSGeneratorOutputPhaseTable 1 } + + XATSGeneratorOutputPhaseEntry ::= SEQUENCE { + xATSGeneratorOutputPhaseIndex INTEGER, + xATSGeneratorOutputVoltageLtoL INTEGER, + xATSGeneratorOutputVoltageLtoN INTEGER, + xATSGeneratorOutputPhaseCurrent INTEGER, + xATSGeneratorOutputPower INTEGER, + xATSGeneratorOutputApparentPower INTEGER, + xATSGeneratorOutputPowerFactor INTEGER + } + + xATSGeneratorOutputPhaseIndex OBJECT-TYPE + SYNTAX INTEGER{ + phase1(1), + phase2(2), + phase3(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of each generator output phase utilized in this device." + ::= { xATSGeneratorOutputPhaseEntry 1 } + + xATSGeneratorOutputVoltageLtoL OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Line-to-line generator output voltage. + Measured in Volts, or -1 if not available." + ::= { xATSGeneratorOutputPhaseEntry 2 } + + xATSGeneratorOutputVoltageLtoN OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Line-to-neutral generator output voltage. + Measured in volts, or -1 if not available." + ::= { xATSGeneratorOutputPhaseEntry 3 } + + xATSGeneratorOutputPhaseCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Generator load current per phase. + Measured in Amps, or -1 if not available." + ::= { xATSGeneratorOutputPhaseEntry 4 } + + xATSGeneratorOutputPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Generator output power per phase. + Measured in tenths of kW, or -1 if not available." + ::= { xATSGeneratorOutputPhaseEntry 5 } + + xATSGeneratorOutputApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Generator output power per phase. + Measured in tenths of kVA, or -1 if not available." + ::= { xATSGeneratorOutputPhaseEntry 6 } + + xATSGeneratorOutputPowerFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the load power factor of the generator output per phase. + A value of 100 representing a unity power factor (1.00), + or -1 if not available." + ::= { xATSGeneratorOutputPhaseEntry 7 } + +-- xATS Generator Settings group + +xATSGeneratorSettingsVoltageAdjust OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage adjust of the generator. + Specified in volts line-to-line, + or -1 if not available." + ::= { xATSGeneratorSettings 1 } + +xATSGeneratorSettingsFrequencyAdjust OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frequency adjust of the generator. + Specified in tenths of Hertz." + ::= { xATSGeneratorSettings 2 } + +xATSGeneratorSettingsStartDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The delay, in seconds, after the remote run signal is activated + before the generator's engine will be cranked to start, + or -1 if not available." + ::= { xATSGeneratorSettings 3 } + +xATSGeneratorSettingsStopDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The delay, in seconds, before the generator will stop + after the remote run signal is deactivated, + or -1 if not available." + ::= { xATSGeneratorSettings 4 } + +xATSGeneratorSettingsCrankCycleEnable OBJECT-TYPE + SYNTAX INTEGER{ + disabled (1), + enabled (2), + unknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When Crank Cycle is enabled, the engine will be cranked up to the time + specified by the xATSGeneratorSettingsCrankTime OID. + If the generator's engine does not start, there will be a pause as + specified by the xATSGeneratorSettingsCrankRestTime OID before the + engine will be cranked again. This cycle is repeated as specified by + the xATSGeneratorSettingsNumberCrank OID. + When crank cycle is disabled, the generator's engine will be + cranked continuously until it starts." + ::= { xATSGeneratorSettings 5 } + +xATSGeneratorSettingsCrankTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The duration of engine cranking, in seconds, when starting the generator. + Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled. + -1 if not available." + ::= { xATSGeneratorSettings 6 } + +xATSGeneratorSettingsCrankRestTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The pause duration, in seconds, following an unsuccessful attempt to start the generator. + Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled. + -1 if not available." + ::= { xATSGeneratorSettings 7 } + +xATSGeneratorSettingsNumberCrank OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of failed crank attempts before giving up on starting the generator. + Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled. + -1 if not available." + ::= { xATSGeneratorSettings 8 } + +xATSGeneratorSettingsMetricUnit OBJECT-TYPE + SYNTAX INTEGER{ + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Specifies the use of metric units in generator related OIDs, as well + as on all other interfaces including the generator's local interface." + ::= { xATSGeneratorSettings 9 } + +-- xATS generator service group + +xATSGeneratorServiceTotalRunHoursLifetime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Total time that the generator engine has been run, + over the life of the generator. Measured in hours. + -1 if not available." + ::= { xATSGeneratorService 1 } + +xATSGeneratorServiceEngineStartsLifetime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of engine starts over the life of the generator. + -1 if not available." + ::= { xATSGeneratorService 2 } + +xATSGeneratorServiceTotalkWhLifetime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Total kWh of operation over the life of the generator. + -1 if not available." + ::= { xATSGeneratorService 3 } + +xATSGeneratorServiceTotalRunHoursSinceMaintenance OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Total time that the generator engine has been run, + since last service maintenance. Measured in tenths of hours. + -1 if not available." + ::= { xATSGeneratorService 4 } + +xATSGeneratorServiceEngineStartsSinceMaintenance OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of engine starts since last service maintenance. + -1 if not available." + ::= { xATSGeneratorService 5 } + +xATSGeneratorServiceTotalkWhMaintenance OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Total kWh of operation since last service maintenance. + -1 if not available." + ::= { xATSGeneratorService 6 } + +xATSGeneratorServiceResetRecord OBJECT-TYPE + SYNTAX INTEGER{ + yes (1), + no (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Resets the engine start counter, engine run-hours, and kWh values that have + accumulated in the generator since last maintenance. + Also, the last service date will be reset to the current system date, and + any service alarms will be cleared." + ::= { xATSGeneratorService 7 } + +xATSGeneratorServiceRecordResetDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Date at which the generator's service record was reset, in dd-mmm-yyyy format." + ::= { xATSGeneratorService 8 } + +xATSGeneratorServiceNextServiceDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Date at which the next generator service is due in dd-mmm-yyyy format. + Based on the xATSGeneratorServiceCalendarIntervalThreshold OID + or '' if the calendar-based threshold is set to off." + ::= { xATSGeneratorService 9 } + +xATSGeneratorServiceRunHoursUntilServiceDate OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Run hours until the next generator service is due, in hours. + Based on the xATSGeneratorServiceRunHoursThreshold OID + or -1 if the run hour-based threshold is set to off." + ::= { xATSGeneratorService 10 } + +xATSGeneratorServiceRunHoursThreshold OBJECT-TYPE + SYNTAX INTEGER{ + disabled (1), + runThreshold100Hours (2), + runThreshold150Hours (3), + runThreshold200Hours (4), + runThreshold250Hours (5), + runThreshold300Hours (6), + runThreshold400Hours (7), + runThreshold500Hours (8) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Run hour-based service interval. When the run-hours since + service surpasses this threshold, generator service is due." + ::= { xATSGeneratorService 11 } + +xATSGeneratorServiceCalendarIntervalThreshold OBJECT-TYPE + SYNTAX INTEGER{ + disabled (1), + interval1month (2), + interval2month (3), + interval3month (4), + interval6month (5), + intervalyearly (6) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Calendar-based service interval. When the next service date, + as indicated by the xATSGeneratorServiceNextServiceDate OID + is in the past, generator is due for service." + ::= { xATSGeneratorService 12 } + +-- The xATS Generator Fuel system group + +xATSGeneratorFuelSystemType OBJECT-TYPE + SYNTAX INTEGER{ + diesel (1), + propane (2), + naturalGas (3), + unknown (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of fuel used by the generator." + ::= { xATSGeneratorFuelSystem 1 } + +xATSGeneratorFuelSystemTankSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Size of the generator's fuel tank. + Specified in gallons or liters, based on the value of the + xATSGeneratorSettingsMetricUnit OID, or -1 if not available." + ::= { xATSGeneratorFuelSystem 2 } + +xATSGeneratorFuelSystemFuelLevel OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fuel remaining in the generator tank. + Measured in percent of tank fill, or -1 if not available." + ::= { xATSGeneratorFuelSystem 3 } + +xATSGeneratorFuelSystemRuntimePower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The power value used in the runtime remaining calculation. + Measured in tenths of kW, or -1 if not available." + ::= { xATSGeneratorFuelSystem 4 } + +xATSGeneratorFuelSystemEstimatedRunTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An estimate of available runtime for the generator, based on + available fuel as specified in the xATSGeneratorFuelSystemFuelLevel OID + and kW load as specified in the xATSGeneratorFuelSystemRuntimePower OID. + Measured in tenths of hours, or -1 if not available." + ::= { xATSGeneratorFuelSystem 5 } + +xATSGeneratorFuelSystemLowRunTimeThreshold OBJECT-TYPE + SYNTAX INTEGER{ + disabled (1), + oneHour (2), + twoHours (3), + threeHours (4), + fourHours (5), + fiveHours (6), + sixHours (7), + twelveHours (8), + oneDay (9), + twoDays (10), + threeDays (11), + fourDays (12), + fiveDays (13), + sixDays (14), + sevenDays (15) + + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold below which a low runtime alarm will exist." + ::= { xATSGeneratorFuelSystem 6 } + +xATSGeneratorFuelSystemVeryLowRunTimeThreshold OBJECT-TYPE + SYNTAX INTEGER{ + disabled (1), + oneHour (2), + twoHours (3), + threeHours (4), + fourHours (5), + fiveHours (6), + sixHours (7), + twelveHours (8), + oneDay (9), + twoDays (10), + threeDays (11), + fourDays (12), + fiveDays (13), + sixDays (14), + sevenDays (15) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold below which a very low runtime alarm will exist." + ::= { xATSGeneratorFuelSystem 7 } + +xATSGeneratorFuelSystemLowFuelLevelThreshold OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold below which a low fuel alarm will exist, with a value of 0 indicating disabled. + Specified as percent of tank fill." + ::= { xATSGeneratorFuelSystem 8 } + +xATSGeneratorFuelSystemVeryLowFuelLevelThreshold OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold below which a very low fuel alarm will exist, with a value of 0 indicating disabled. + Specified as percent of tank fill." + ::= { xATSGeneratorFuelSystem 9 } + +-- The console Port Server AP930x system group + +apCPSpname OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "The product's name." +::= { cpsAP930xSys 1 } + +apCPSversion OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "The firmware's version." +::= {cpsAP930xSys 2} + +apCPSPower OBJECT IDENTIFIER ::= { cpsAP930xSys 3 } + +apCPSPwNum OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS mandatory + DESCRIPTION "The number of the power supplies." +::= { apCPSPower 1 } + +apCPSPw1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "State of the first power supply. + 0 will indicate not installed, + 1 will indicate power ON, + 2 will indicate power OFF." +::= { apCPSPower 2 } + +apCPSPw2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "State of the second power supply. + 0 will indicate not installed, + 1 will indicate power ON, + 2 will indicate power OFF." +::= { apCPSPower 3 } + +apCPSPcmcia OBJECT IDENTIFIER ::= {cpsAP930xSys 4} + +apCPSNPcmcia OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS mandatory + DESCRIPTION "Number of PCMCIA cards available." +::= { apCPSPcmcia 1 } + +cpsCardIdentTable OBJECT-TYPE + SYNTAX SEQUENCE OF CpsCardIdentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "A table of PCMCIA card identifications." +::= { apCPSPcmcia 2 } + +cpsCardIdentEntry OBJECT-TYPE + SYNTAX CpsCardIdentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "Identification information for a PCMCIA card." + INDEX { cpsCardIdentIndex } +::= { cpsCardIdentTable 1 } + +CpsCardIdentEntry ::= SEQUENCE { + cpsCardIdentIndex Integer32, + cpsCardIdentProd DisplayString, + cpsCardIdentMan DisplayString , + cpsCardIdentFunc DisplayString, + cpsCardIdentPCI DisplayString +} + +cpsCardIdentIndex OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS mandatory + DESCRIPTION "Number to identify the socket Card." +::= { cpsCardIdentEntry 1 } + +cpsCardIdentProd OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "Product identification string." +::= { cpsCardIdentEntry 2 } + +cpsCardIdentMan OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "Manufacturer ID code." +::= { cpsCardIdentEntry 3 } + +cpsCardIdentFunc OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "Function ID code." +::= { cpsCardIdentEntry 4 } + +cpsCardIdentPCI OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "PCI ID" +::= { cpsCardIdentEntry 5 } + +cpsCardConfTable OBJECT-TYPE + SYNTAX SEQUENCE OF CpsCardConfEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "A table of socket configuration information." +::= { apCPSPcmcia 3 } + +cpsCardConfEntry OBJECT-TYPE + SYNTAX CpsCardConfEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "Configuration information for a socket." + INDEX { cpsCardConfIndex } +::= { cpsCardConfTable 1 } + +CpsCardConfEntry ::= SEQUENCE { + cpsCardConfIndex Integer32, + cpsCardConfPower DisplayString, + cpsCardConfType DisplayString, + cpsCardConfInter DisplayString, + cpsCardConfFunc DisplayString, + cpsCardConfCardv DisplayString, + cpsCardConfPort1 DisplayString, + cpsCardConfPort2 DisplayString +} + +cpsCardConfIndex OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS mandatory + DESCRIPTION "Number to identify the socket PCMCIA." +::= { cpsCardConfEntry 1 } + +cpsCardConfPower OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "Power Settings." +::= { cpsCardConfEntry 2 } + +cpsCardConfType OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "Interface Type." +::= { cpsCardConfEntry 3 } + +cpsCardConfInter OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "Interrupt number." +::= { cpsCardConfEntry 4 } + +cpsCardConfFunc OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "Function." +::= { cpsCardConfEntry 5 } + +cpsCardConfCardv OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "Card values." +::= { cpsCardConfEntry 6 } + +cpsCardConfPort1 OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "I/O Port 1." +::= { cpsCardConfEntry 7 } + +cpsCardConfPort2 OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "I/O Port 2." +::= { cpsCardConfEntry 8 } + +cpsCardStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF CpsCardStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "A table of current socket status information." +::= { apCPSPcmcia 4 } + +cpsCardStatusEntry OBJECT-TYPE + SYNTAX CpsCardStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "Current status information for a socket." + INDEX { cpsCardStatusIndex } +::= { cpsCardStatusTable 1 } + +CpsCardStatusEntry ::= SEQUENCE { + cpsCardStatusIndex Integer32, + cpsCardStatusCard DisplayString, + cpsCardStatusFunc DisplayString +} + +cpsCardStatusIndex OBJECT-TYPE + SYNTAX Integer32(0..2) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Number to identify the socket PCMCIA." +::= { cpsCardStatusEntry 1 } + +cpsCardStatusCard OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "Current Card State." +::= { cpsCardStatusEntry 2 } + +cpsCardStatusFunc OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "Current Function." +::= { cpsCardStatusEntry 3 } + +apCPSFlashSize OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS mandatory + DESCRIPTION "Total amount of flash memory in Mbytes." +::= {cpsAP930xSys 5} + +apCPSRAMSize OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS mandatory + DESCRIPTION "Total amount of RAM in Mbytes." +::= {cpsAP930xSys 6} + +apCPSCPUfreq OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS mandatory + DESCRIPTION "CPU clock in MHz." +::= {cpsAP930xSys 7} + +apCPSDevId OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "The product's identifier." +::= { cpsAP930xSys 8 } + + +-- The console Port Server AP930x configuration group + +cpsHostName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..40)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "The Host Name." +::= { cpsAP930xConf 1 } + +cpsConsoleBanner OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "The console banner." +::= { cpsAP930xConf 2 } + +cpsMotd OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "The motd message." +::= { cpsAP930xConf 3 } + +cpsEthItf OBJECT IDENTIFIER ::= { cpsAP930xConf 4 } + +cpsEthDhcpc OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION "0 will indicate DHCP inactive, + 1 will indicate DHCP active, + 2 will indicate DHCP active and the last parameter is saved." +::= { cpsEthItf 1 } + +cpsEthIPaddr OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION "This is the IP address of the Ethernet Interface." +::= { cpsEthItf 2 } + +cpsEthIPmask OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION "The mask for the Ethernet network." +::= { cpsEthItf 3 } + +cpsEthMTU OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-write + STATUS mandatory + DESCRIPTION "The Maximum Transmission Unit size, which determines + whether packets should be broken up." +::= { cpsEthItf 4 } + +cpsEthIPaddr2 OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION "The Ethernet secondary IP address." +::= { cpsEthItf 5 } + +cpsEthIPmask2 OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION "The Ethernet secondary IP mask." +::= { cpsEthItf 6 } + +cpsNameService OBJECT IDENTIFIER ::= { cpsAP930xConf 5 } + +cpsResolverOrder OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Specifies how host lookups are to be performed. + Valid values : empty, 'hosts', 'bind', 'hosts, bind', + 'bind, hosts' " +::= { cpsNameService 1 } + +cpsMultipleIP OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..3)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Valid values are ON or OFF. If set to ON, the resolve + library will return all valid addresses for a host + that appears in the /etc/hosts file, instead of only + the first. " +::= { cpsNameService 2 } + +cpsDNSserv OBJECT IDENTIFIER ::= { cpsNameService 3 } + +cpsDNSpriserv OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION "Internet Address (in dot notation) of primary name + server that the resolver should query." +::= { cpsDNSserv 1 } + +cpsDNSsecserv OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION "Internet Address (in dot notation) of secondary name + server that the resolver should query." +::= { cpsDNSserv 2 } + +cpsDNSdomain OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..40)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Local domain name." +::= { cpsDNSserv 3 } + +cpsSerialPortConf OBJECT IDENTIFIER ::= { cpsAP930xConf 6 } + +cpsSerialGlobal OBJECT IDENTIFIER ::= { cpsSerialPortConf 1 } + +cpsSerialInclude OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..40)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "File used in centralized management." +::= { cpsSerialGlobal 1 } + +cpsSerialNFS OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..50)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Remote Network File System where data buffering will be + written instead of the default directory '/var/run/DB'." +::= { cpsSerialGlobal 2 } + +cpsSerialLockDir OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..50)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "The lock directory." +::= { cpsSerialGlobal 3 } + +cpsSerialRlogin OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..50)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Location of the rlogin binary that accepts the -i flag." +::= { cpsSerialGlobal 4 } + +cpsSerialPppd OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..50)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Location of the pppd binary." +::= { cpsSerialGlobal 5 } + +cpsSerialTelnet OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..50)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Location of the telnet application." +::= { cpsSerialGlobal 6 } + +cpsSerialSsh OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..50)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Location of the ssh application." +::= { cpsSerialGlobal 7 } + +cpsSerialLocalLogins OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION "This parameter is only necessary when authentication is + being performed for a port. + This is useful if the Radius authentication server is down. + 0 indicates OFF, + 1 indicates ON." +::= { cpsSerialGlobal 8 } + +cpsSerialFacility OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-write + STATUS mandatory + DESCRIPTION "This value (0-7) is the Local facility sent to the syslog daemon." +::= { cpsSerialGlobal 9 } + +cpsSerialDBFacility OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-write + STATUS mandatory + DESCRIPTION "This value (0-7) is the Local facility sent to the syslog daemon." +::= { cpsSerialGlobal 10 } + +cpsSerialGroupTable OBJECT-TYPE + SYNTAX SEQUENCE OF CpsSerialGroupEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "" +::= { cpsSerialGlobal 11 } + +cpsSerialGroupEntry OBJECT-TYPE + SYNTAX CpsSerialGroupEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "" + INDEX { cpsSerialGroupIndex } +::= { cpsSerialGroupTable 1 } + +CpsSerialGroupEntry ::= SEQUENCE { + cpsSerialGroupIndex INTEGER, + cpsSerialGroupName DisplayString, + cpsSerialGroupUsers DisplayString +} + +cpsSerialGroupIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Number to identify the group." +::= { cpsSerialGroupEntry 1 } + +cpsSerialGroupName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..20)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "The group name." +::= { cpsSerialGroupEntry 2 } + +cpsSerialGroupUsers OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..80)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "The user's names." +::= { cpsSerialGroupEntry 3 } + +cpsSerialSpec OBJECT IDENTIFIER ::= { cpsSerialPortConf 2 } + +cpsSerialPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF CpsSerialPortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "This is the specific configuration per serial port." +::= { cpsSerialSpec 1 } + +cpsSerialPortEntry OBJECT-TYPE + SYNTAX CpsSerialPortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "One particular serial port configuration." + INDEX { cpsSerialPortNumber } +::= { cpsSerialPortTable 1 } + +CpsSerialPortEntry ::= SEQUENCE { + cpsSerialPortNumber INTEGER, -- 0 == all. X == ttyX sX. + cpsSerialPortTty DisplayString, -- associate device + cpsSerialPortName DisplayString, -- alias name + cpsSerialPortSpeed Integer32, -- physical port configuration + cpsSerialPortDataSize Integer32, + cpsSerialPortStopBits Integer32, + cpsSerialPortParity DisplayString, + cpsSerialPortFlowCtrl DisplayString, + cpsSerialPortDTRdelay Integer32, + cpsSerialPortDCDCtrl INTEGER, + cpsSerialPortLogUtmp INTEGER, -- log into UTMP + cpsSerialPortLogWtmp INTEGER, -- log into WTMP + cpsSerialPortLogform DisplayString, + cpsSerialPortAuthtype DisplayString, -- authentication type + cpsSerialPortAuthSrv1 IpAddress, -- IP address of the primary authentication server + cpsSerialPortAccSrv1 IpAddress, -- IP address of the primary accounting server + cpsSerialPortAuthTmo Integer32, -- time out per authentication query + cpsSerialPortAuthRetr Integer32, -- authentication number of retries + cpsSerialPortAuthSrv2 IpAddress, -- IP address of the secondary authentication server + cpsSerialPortAccSrv2 IpAddress, -- IP address of the secondary accounting server + cpsSerialPortAuthSecret DisplayString, -- secret used in authentication + cpsSerialPortAuthRadP INTEGER, -- accept RADIUS' user without password + cpsSerialPortAuthAcc DisplayString, -- access restriction on Users + cpsSerialPortProtocol DisplayString, -- Profile + cpsSerialPortRemoteIP DisplayString, -- remote IP address + cpsSerialPortSocketPort DisplayString, -- number of socket port + cpsSerialPortRemHost IpAddress, -- IP address of the remote Host + cpsSerialPortBanner DisplayString, -- Banner + cpsSerialPortPrompt DisplayString, -- Login prompt + cpsSerialPortTermType DisplayString, -- terminal type + cpsSerialPortAutomUsr DisplayString, -- automatic user + cpsSerialPortNetMask IpAddress, -- net mask + cpsSerialPortPppMtu Integer32, + cpsSerialPortPppMru Integer32, + cpsSerialPortPppOptions DisplayString, + cpsSerialPortPppFoption DisplayString, + cpsSerialPortModemChat DisplayString, -- initchat send to modem + cpsSerialPortSttyCmd DisplayString, + cpsSerialPortSockTx Integer32, -- socket transmission interval + cpsSerialPortSockPoll Integer32, -- socket polling interval + cpsSerialPortSockIdle Integer32, -- socket idle timeout + cpsSerialPortDBsize Integer32, -- maximum size of the data buffering file + cpsSerialPortDBtime INTEGER, -- data buffering with/without timestamp + cpsSerialPortDBmode DisplayString, -- data bufferinf mode circ or line + cpsSerialPortDBsyslog Integer32, -- size of the data send to syslog + cpsSerialPortDBmenu INTEGER, -- menu of the data buffering + cpsSerialPortDBalarm INTEGER, -- use alarm generating feature + cpsSerialPortSSHbreak DisplayString, -- break sequence (SSH) + cpsSerialPortSniffSess DisplayString, -- sniff session type + cpsSerialPortSniffAdm DisplayString, -- admin users to sniff + cpsSerialPortSniffEsc DisplayString, -- escape char to sniff session + cpsSerialPortSniffMsess DisplayString, -- multiple session + cpsSerialPortTelnetMode INTEGER, -- telnet client mode + cpsSerialPortSysBufSess INTEGER, -- syslog buffering at all times + cpsSerialPortLFSuppress INTEGER, -- LF suppression in socket_server session + cpsSerialPortAutoInput DisplayString, -- Input string to auto answer + cpsSerialPortAutoOutput DisplayString, -- Output string to auto answer + cpsSerialPortBreakInterval Integer32 -- Break interval (in ms) +} + +cpsSerialPortNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Number to identify the serial port. Value 0 is ALL." +::= { cpsSerialPortEntry 1 } + +cpsSerialPortTty OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..25)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "The device name for the serial port." +::= { cpsSerialPortEntry 2 } + +cpsSerialPortName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..40)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Alias name given to the server connected to the serial port." +::= { cpsSerialPortEntry 3 } + +cpsSerialPortSpeed OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-write + STATUS mandatory + DESCRIPTION "The speed of the serial port. + Supported values are: + 50, 75, 110, 134, 150, 200, 300, 600, + 1200, 1800, 2400, 4800, 9600, 14400, 19200, + 28800, 38400, 57600, 115200, 230400, and 460800" +::= { cpsSerialPortEntry 4 } + +cpsSerialPortDataSize OBJECT-TYPE + SYNTAX Integer32 (4..8) + ACCESS read-write + STATUS mandatory + DESCRIPTION "The data size for the serial port." +::= { cpsSerialPortEntry 5 } + +cpsSerialPortStopBits OBJECT-TYPE + SYNTAX Integer32 (0..2) + ACCESS read-write + STATUS mandatory + DESCRIPTION "The number of stop bits for the serial port." +::= { cpsSerialPortEntry 6 } + +cpsSerialPortParity OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..5)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "The parity for the serial port." +::= { cpsSerialPortEntry 7 } + +cpsSerialPortFlowCtrl OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..5)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "The flow control for the serial port." +::= { cpsSerialPortEntry 8 } + +cpsSerialPortDTRdelay OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-write + STATUS mandatory + DESCRIPTION "This specifies how long (in milliseconds) a DTR signal + will be turned off before it is turned on again." +::= { cpsSerialPortEntry 9 } + +cpsSerialPortDCDCtrl OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION "DCD signal controls the connection request. + 0 will indicate nocontrol, + 1 will indicate control." +::= { cpsSerialPortEntry 10 } + +cpsSerialPortLogUtmp OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION "Update the login records in /var/run/utmp file. + 0 will indicate inactive, + 1 will indicate active." +::= { cpsSerialPortEntry 11 } + +cpsSerialPortLogWtmp OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION "Update the login records in /var/run/wtmp file. + 0 will indicate inactive, + 1 will indicate active." +::= { cpsSerialPortEntry 12 } + +cpsSerialPortLogform OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..40)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "This is the format to write the login record." +::= { cpsSerialPortEntry 13 } + +cpsSerialPortAuthtype OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..25)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Authentication type." +::= { cpsSerialPortEntry 14 } + +cpsSerialPortAuthSrv1 OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION "IP address of the primary authentication server." +::= { cpsSerialPortEntry 15 } + +cpsSerialPortAccSrv1 OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION "IP address of the primary accounting server." +::= { cpsSerialPortEntry 16 } + +cpsSerialPortAuthTmo OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-write + STATUS mandatory + DESCRIPTION "This is the timeout (in seconds) for the authentication + query to be answered." +::= { cpsSerialPortEntry 17 } + +cpsSerialPortAuthRetr OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-write + STATUS mandatory + DESCRIPTION "This defines the number of times each server is tried + before another is contacted." +::= { cpsSerialPortEntry 18 } + +cpsSerialPortAuthSrv2 OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION "IP address of the secondary authentication server." +::= { cpsSerialPortEntry 19 } + +cpsSerialPortAccSrv2 OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION "IP address of the secondary accounting server." +::= { cpsSerialPortEntry 20 } + +cpsSerialPortAuthSecret OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..40)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "This is the shared secret with authentication servers." +::= { cpsSerialPortEntry 21 } + +cpsSerialPortAuthRadP OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION "Radius state. + 0 will indicate inactive, + 1 will indicate active." +::= { cpsSerialPortEntry 22 } + +cpsSerialPortAuthAcc OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..40)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Access restriction." +::= { cpsSerialPortEntry 23 } + +cpsSerialPortProtocol OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..40)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Defines the serial port's protocol." +::= { cpsSerialPortEntry 24 } + +cpsSerialPortRemoteIP OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..20)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "This is the default IP address of the serial port." +::= { cpsSerialPortEntry 25 } + +cpsSerialPortSocketPort OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..10)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "This defines an alternative labeling system for the serial port." +::= { cpsSerialPortEntry 26 } + +cpsSerialPortRemHost OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION "The IP address of the host to which the serial port will connect." +::= { cpsSerialPortEntry 27 } + +cpsSerialPortBanner OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..250)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "This defines the banner." +::= { cpsSerialPortEntry 28 } + +cpsSerialPortPrompt OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..250)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "This defines the login prompt to the serial port." +::= { cpsSerialPortEntry 29 } + +cpsSerialPortTermType OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..20)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "This defines the terminal type." +::= { cpsSerialPortEntry 30 } + +cpsSerialPortAutomUsr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..40)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "This defines the automatic user." +::= { cpsSerialPortEntry 31 } + +cpsSerialPortNetMask OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION "The network mask used in dial in connection." +::= { cpsSerialPortEntry 32 } + +cpsSerialPortPppMtu OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-write + STATUS mandatory + DESCRIPTION "The PPP MTU - dial in connection." +::= { cpsSerialPortEntry 33 } + +cpsSerialPortPppMru OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-write + STATUS mandatory + DESCRIPTION "The PPP MRU - dial in connection." +::= { cpsSerialPortEntry 34 } + +cpsSerialPortPppOptions OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION "The PPP options when the PPP session is autodetected." +::= { cpsSerialPortEntry 35 } + +cpsSerialPortPppFoption OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION "The PPP forced options when the user has already been authenticated." +::= { cpsSerialPortEntry 36 } + +cpsSerialPortModemChat OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION "The initchat send to modem connected." +::= { cpsSerialPortEntry 37 } + +cpsSerialPortSttyCmd OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..180)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "The tty settings after socket connection is established." +::= { cpsSerialPortEntry 38 } + +cpsSerialPortSockTx OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-write + STATUS mandatory + DESCRIPTION "Defines the delay (in milliseconds) before transmission to + the Ethernet of data received through a serial port." +::= { cpsSerialPortEntry 39 } + +cpsSerialPortSockPoll OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-write + STATUS mandatory + DESCRIPTION "Keep-alive timer (milliseconds) for the TCP connection." +::= { cpsSerialPortEntry 40 } + +cpsSerialPortSockIdle OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-write + STATUS mandatory + DESCRIPTION "The idle timeout in seconds." +::= { cpsSerialPortEntry 41 } + +cpsSerialPortDBsize OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-write + STATUS mandatory + DESCRIPTION "Maximum size of the data buffering file." +::= { cpsSerialPortEntry 42 } + +cpsSerialPortDBtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION "Timestamp in data buffering. + 0 will indicate inactive, + 1 will indicate active." +::= { cpsSerialPortEntry 43 } + +cpsSerialPortDBmode OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..5)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Data buffering mode : circ or line." +::= { cpsSerialPortEntry 44 } + +cpsSerialPortDBsyslog OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-write + STATUS mandatory + DESCRIPTION "Size of the data buffer sent to syslog." +::= { cpsSerialPortEntry 45 } + +cpsSerialPortDBmenu OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION "Menu type for data buffering. + 0 will indicate display Menu, + 1 will indicate inactive, + 2 will indicate DB, + 3 will indicate Parc." +::= { cpsSerialPortEntry 46 } + +cpsSerialPortDBalarm OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION "Alarm generation status. + 0 will indicate inactive, + 1 will indicate active." +::= { cpsSerialPortEntry 47 } + +cpsSerialPortSSHbreak OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..16)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Break sequence - ssh session." +::= { cpsSerialPortEntry 48 } + +cpsSerialPortSniffSess OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..5)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Sniff session type." +::= { cpsSerialPortEntry 49 } + +cpsSerialPortSniffAdm OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..40)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "List of admin users allowed to sniff session." +::= { cpsSerialPortEntry 50 } + +cpsSerialPortSniffEsc OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..6)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Escape sequence used in sniff session." +::= { cpsSerialPortEntry 51 } + +cpsSerialPortSniffMsess OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..20)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "" +::= { cpsSerialPortEntry 52 } + +cpsSerialPortTelnetMode OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION "Mode negotiated by client telnet with the server. + 0 will indicate text, + 1 will indicate binary." +::= { cpsSerialPortEntry 53 } + +cpsSerialPortSysBufSess OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION "Syslog Buffering at all times. + 0 will indicate yes, + 1 will indicate no." +::= { cpsSerialPortEntry 54 } + +cpsSerialPortLFSuppress OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION "LF suppression in socket_server session. + 0 will indicate inactive, + 1 will indicate active." +::= { cpsSerialPortEntry 55 } + +cpsSerialPortAutoInput OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..40)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Input string used for auto answer." +::= { cpsSerialPortEntry 56 } + +cpsSerialPortAutoOutput OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..40)) + ACCESS read-write + STATUS mandatory + DESCRIPTION "Output string used for auto answer." +::= { cpsSerialPortEntry 57 } + +cpsSerialPortBreakInterval OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-write + STATUS mandatory + DESCRIPTION "The break interval in milliseconds." +::= { cpsSerialPortEntry 58 } + +-- The console Port Server AP930x information group + +cpsInfoSerialPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF CpsInfoSerialPortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "This is the information of the specific serial port." +::= { cpsAP930xInfo 1 } + +cpsInfoSerialPortEntry OBJECT-TYPE + SYNTAX CpsInfoSerialPortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "One particular serial port." + INDEX { cpsInfoSerialPortNumber } +::= { cpsInfoSerialPortTable 1 } + +CpsInfoSerialPortEntry ::= SEQUENCE { + cpsInfoSerialPortNumber INTEGER, -- X == ttyX sX. + cpsInfoSerialPortTty DisplayString, -- associate device + cpsInfoSerialPortName DisplayString, -- alias name + cpsInfoSerialPortSpeed Integer32, + cpsInfoSerialPortTxBytes Integer32, + cpsInfoSerialPortRXBytes Integer32, + cpsInfoSerialPortErrFrame Integer32, + cpsInfoSerialPortErrParity Integer32, + cpsInfoSerialPortErrBreaks Integer32, + cpsInfoSerialPortErrOverrun Integer32, + cpsInfoSerialPortSigDTR INTEGER, + cpsInfoSerialPortSigCD INTEGER, + cpsInfoSerialPortSigDSR INTEGER, + cpsInfoSerialPortSigRTS INTEGER, + cpsInfoSerialPortSigCTS INTEGER, + cpsInfoSerialPortSigRI INTEGER + } + +cpsInfoSerialPortNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Number to identify the serial port." +::= { cpsInfoSerialPortEntry 1 } + +cpsInfoSerialPortTty OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "The device name for the serial port." +::= { cpsInfoSerialPortEntry 2 } + +cpsInfoSerialPortName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "Alias name given to the server connected to the serial port." +::= { cpsInfoSerialPortEntry 3 } + +cpsInfoSerialPortSpeed OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS mandatory + DESCRIPTION "The speed for serial port." +::= { cpsInfoSerialPortEntry 4 } + +cpsInfoSerialPortTxBytes OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS mandatory + DESCRIPTION "The number of transmitted bytes by the serial port." +::= { cpsInfoSerialPortEntry 5 } + +cpsInfoSerialPortRXBytes OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS mandatory + DESCRIPTION "The number of received bytes by the serial port." +::= { cpsInfoSerialPortEntry 6 } + +cpsInfoSerialPortErrFrame OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS mandatory + DESCRIPTION "The number of frame errors." +::= { cpsInfoSerialPortEntry 7 } + +cpsInfoSerialPortErrParity OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS mandatory + DESCRIPTION "The number of parity errors." +::= { cpsInfoSerialPortEntry 8 } + +cpsInfoSerialPortErrBreaks OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS mandatory + DESCRIPTION "The number of breaks errors." +::= { cpsInfoSerialPortEntry 9 } + +cpsInfoSerialPortErrOverrun OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS mandatory + DESCRIPTION "The number of overrun errors." +::= { cpsInfoSerialPortEntry 10 } + +cpsInfoSerialPortSigDTR OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "The state of the DTR signal. + 0 will indicate down, + 1 will indicate up." +::= { cpsInfoSerialPortEntry 11 } + +cpsInfoSerialPortSigCD OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "The state of the DCD signal. + 0 will indicate down, + 1 will indicate up." +::= { cpsInfoSerialPortEntry 12 } + +cpsInfoSerialPortSigDSR OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "The state of the DSR signal. + 0 will indicate down, + 1 will indicate up." +::= { cpsInfoSerialPortEntry 13 } + +cpsInfoSerialPortSigRTS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "The state of the RTS signal. + 0 will indicate down, + 1 will indicate up." +::= { cpsInfoSerialPortEntry 14 } + +cpsInfoSerialPortSigCTS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "The state of the CTS signal. + 0 will indicate down, + 1 will indicate up." +::= { cpsInfoSerialPortEntry 15 } + +cpsInfoSerialPortSigRI OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "The state of the RI signal. + 0 will indicate down, + 1 will indicate up." +::= { cpsInfoSerialPortEntry 16 } + +-- The console Port Server AP930x administrative group + +apCPSSave OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION "Exec saveconf command. + 0 will indicate don't save, + 1 will indicate save." +::= { cpsAP930xAdm 1 } + +apCPSSerialHUP OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION "Exec signal_ras hup command. + 0 will indicate no restart, + 1 will indicate restart." +::= { cpsAP930xAdm 2 } + +-- the access PX group + +accessPXIdentAlarmStatus OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Access PX alarm status + 1 = Normal + 2 = Warning + 3 = Critical." + ::= { accessPXIdent 1 } + + +accessPXIdentProductNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The product number of the Access PX." + ::= { accessPXIdent 2 } + +accessPXIdentHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision number of the Access PX." + ::= { accessPXIdent 3 } + +accessPXIdentDateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date of manufacture of the Access PX." + ::= { accessPXIdent 4 } + +accessPXIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the Access PX." + ::= { accessPXIdent 5 } + +accessPXConfigCardReaderEnableDisableAction OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Action to disable/enable the card reader." + ::= { accessPXConfig 1 } + +accessPXConfigAutoRelockTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Time (10 - 60) in seconds when the door will automatically relock + after it has been unlocked and the handle has not been opened." + ::= { accessPXConfig 2 } + +accessPXConfigCardFormat OBJECT-TYPE + SYNTAX INTEGER { + hidStd26 (1), + hid37Bit (2), + hid37BitWithFacility (3), + hidCorp1000 (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Indicates and controls the HID card format. + NOTE: This OID is only valid for HID systems." + ::= { accessPXConfig 3 } + +accessPXConfigFrontDoorLockControl OBJECT-TYPE + SYNTAX INTEGER { + unlock (1), + lock (2), + notInstalledReadOnly (3), + disconnectedReadOnly (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Control action (unlock, lock) for the front door. Setting this OID + will unlock or lock the front door. Getting this OID will respond + with the current state of the front door lock which could be + 1 = unlocked, + 2 = locked, + 3 = not installed, + 4 = disconnected." + ::= { accessPXConfigFront 1 } + +accessPXConfigFrontDoorMaxOpenTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Time in minutes, (1 - 120), that the front door can be + allowed to remain open without generating an alarm condition." + ::= { accessPXConfigFront 2 } + +accessPXStatusFrontDoorLock OBJECT-TYPE + SYNTAX INTEGER { + unlocked (1), + locked (2), + notInstalled (3), + disconnected (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Present state of the front door lock: unlocked, locked, + not installed, or disconnected." + ::= { accessPXStatusFront 1 } + +accessPXStatusFrontDoor OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2), + notInstalled (3), + disconnected (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Present state of the front door: open, closed, + not installed, or disconnected." + ::= { accessPXStatusFront 2 } + +accessPXStatusFrontDoorHandle OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2), + notInstalled (3), + disconnected (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Present state of the front door handle: open, closed, + not installed, or disconnected." + ::= { accessPXStatusFront 3 } + +accessPXStatusFrontDoorMaxOpenTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Time in minutes, (1 - 120), that the front door can be + allowed to remain open without generating an alarm condition." + ::= { accessPXStatusFront 4 } + +accessPXStatusFrontDoorAlarmStatus OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Front door alarm status + 1 = Normal + 2 = Warning + 3 = Critical + 4 = Front door not installed." + ::= { accessPXStatusFront 5 } + +accessPXConfigRearDoorLockControl OBJECT-TYPE + SYNTAX INTEGER { + unlock (1), + lock (2), + notInstalledReadOnly (3), + disconnectedReadOnly (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Control action (unlock, lock) for the rear door. Setting this OID + will unlock or lock the rear door. Getting this OID will respond + with the current state of the rear door lock which could be + 1 = unlocked, + 2 = locked, + 3 = not installed, + 4 = disconnected." + ::= { accessPXConfigRear 1 } + +accessPXConfigRearDoorMaxOpenTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Time in minutes, (1 - 120), that the rear door can be + allowed to remain open without generating an alarm condition." + ::= { accessPXConfigRear 2 } + +accessPXStatusRearDoorLock OBJECT-TYPE + SYNTAX INTEGER { + unlocked (1), + locked (2), + notInstalled (3), + disconnected (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Present state of the rear door lock: unlocked, locked, + not installed, or disconnected." + ::= { accessPXStatusRear 1 } + +accessPXStatusRearDoor OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2), + notInstalled (3), + disconnected (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Present state of the rear door: open, closed, + not installed, or disconnected." + ::= { accessPXStatusRear 2 } + +accessPXStatusRearDoorHandle OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2), + notInstalled (3), + disconnected (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Present state of the rear door handle: open, closed, + not installed, or disconnected." + ::= { accessPXStatusRear 3 } + +accessPXStatusRearDoorMaxOpenTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Time in minutes, (1 - 120), that the rear door can be + allowed to remain open without generating an alarm condition." + ::= { accessPXStatusRear 4 } + +accessPXStatusRearDoorAlarmStatus OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Rear door alarm status + 1 = Normal + 2 = Warning + 3 = Critical + 4 = Rear door not installed." + ::= { accessPXStatusRear 5 } + +accessPXConfigBeaconName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A descriptive name for the Beacon." + ::= { accessPXConfigBeacon 1 } + +accessPXConfigBeaconLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A descriptive name for the location of the Beacon." + ::= { accessPXConfigBeacon 2 } + +accessPXConfigBeaconAction OBJECT-TYPE + SYNTAX INTEGER { + turnOff (1), + turnOn (2), + notInstalledReadOnly (3), + disconnectedReadOnly (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Control action (turnOff, turnOn) for the beacon. Setting this OID + will turn the beacon off or on. Getting this OID will respond + with the current state which could be + 1 = off, + 2 = on, + 3 = not installed, + 4 = disconnected." + ::= { accessPXConfigBeacon 3 } + +accessPXStatusBeaconName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the beacon." + ::= { accessPXStatusBeacon 1 } + +accessPXStatusBeaconLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the location of the beacon." + ::= { accessPXStatusBeacon 2 } + +accessPXStatusBeaconCurrentState OBJECT-TYPE + SYNTAX INTEGER { + off (1), + on (2), + notInstalled (3), + disconnected (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current state of the beacon: off, on, + not installed, or disconnected." + ::= { accessPXStatusBeacon 3 } + +-- the apcLocalDisplay group + +apcLocalDisplayIdentDisplayType OBJECT-TYPE + SYNTAX INTEGER { + noDisplayFound (1), + powerviewRM (2), + powerviewWW (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Numeric value used to identify the type of display in use." + ::= { apcLocalDisplayIdent 1 } + +apcLocalDisplayIdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The model number of the local display." + ::= { apcLocalDisplayIdent 2 } + +apcLocalDisplayIdentFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision number of the local display." + ::= { apcLocalDisplayIdent 3 } + +apcLocalDisplayIdentOptions OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A display-specific string identifying options in the local display." + ::= { apcLocalDisplayIdent 4 } + +apcLocalDisplayIdentDateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date of manufacture of the local display, if available." + ::= { apcLocalDisplayIdent 5 } + +apcLocalDisplayIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the local display, if available." + ::= { apcLocalDisplayIdent 6 } + +apcLocalDisplayConfigAlarmBeeper OBJECT-TYPE + SYNTAX INTEGER { + beeperDisabled (1), + beeperEnabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The alarm beeper setting for the local display. + When enabled, the alarm beeper will begin to sound whenever + there a new alarm becomes active. The alarm beeper will continue to + periodically sound until a key is pressed on the display." + ::= { apcLocalDisplayConfig 1 } + +apcLocalDisplayConfigBeeperVolume OBJECT-TYPE + SYNTAX INTEGER { + beeperDisabled (1), + beeperLow (2), + beeperMedium (3), + beeperHigh (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The volume setting of the beeper on the local display." + ::= { apcLocalDisplayConfig 2 } + +apcLocalDisplayConfigCheckLogIndicator OBJECT-TYPE + SYNTAX INTEGER { + checklogNotPresent (1), + checklogDisabled (2), + checklogInformational (3), + checklogWarning (4), + checklogCritical (5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The minimum level event severity level required to illuminate + the check log light on the local display. + notPresent (1) indicates that the display does not have a check log light." + ::= { apcLocalDisplayConfig 3 } + +apcLocalDisplayConfigKeyClick OBJECT-TYPE + SYNTAX INTEGER { + keyclickDisabled (1), + keyclickEnabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The key click setting of the local display." + ::= { apcLocalDisplayConfig 4 } + +apcLocalDisplayConfigContrast OBJECT-TYPE + SYNTAX INTEGER { + contrast1 (1), + contrast2 (2), + contrast3 (3), + contrast4 (4), + contrast5 (5), + contrast6 (6), + contrast7 (7), + contrast8 (8) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The contrast level of the local display." + ::= { apcLocalDisplayConfig 5 } + +-- the software group +-- the powerNetSubAgent group +-- the powerNetSoftwareSystem group + +powerNetSoftwareSystemDescription OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..79)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A brief description of the PowerNet sub-agent." + ::= { powerNetSoftwareSystem 1 } + +powerNetSoftwareOid OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The object identifier of the PowerNet sub-agent." + ::= { powerNetSoftwareSystem 2 } + +-- powerNetSmuxPeer OBJECT IDENTIFIER ::= { powerNetSoftwareOid 1 } +-- powerNetDPIPeer OBJECT IDENTIFIER ::= { powerNetSoftwareOid 2 } + +powerNetSoftwareSystemUpTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The time that the sub-agent has been running." + ::= { powerNetSoftwareSystem 3 } + + +-- powerNetSoftwareConfig group + +powerNetSoftwareTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of software modules supporting the UPS." + ::= { powerNetSoftwareConfig 1 } + +powerNetSoftwareTable OBJECT-TYPE + SYNTAX SEQUENCE OF PowerNetSoftwareEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of the software monitoring the UPS." + ::= { powerNetSoftwareConfig 2 } + +powerNetSoftwareEntry OBJECT-TYPE + SYNTAX PowerNetSoftwareEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information on a software module." + INDEX { moduleNumber } + ::= { powerNetSoftwareTable 1 } + +PowerNetSoftwareEntry ::= + SEQUENCE { + moduleNumber + INTEGER, + moduleName + DisplayString, + moduleVersion + DisplayString, + moduleDate + DisplayString + } + +moduleNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index into the Software Entry Table" + ::= { powerNetSoftwareEntry 1 } + +moduleName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..79)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the software module." + ::= { powerNetSoftwareEntry 2 } + +moduleVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..8)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The version of the software module." + ::= { powerNetSoftwareEntry 3 } + +moduleDate OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..9)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date of the software module represented as mm-dd-yy." + ::= { powerNetSoftwareEntry 4 } + +-- the StruxureWare Operations group + +serverStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + stopped(2), + running(3), + running-missing(4), + initializing(5), + starting(6), + disaster-recovery(7), + postoffice-inconsistent(8), + missing-jgroups(9) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the StruxureWare Operations server: + 1: The status of the application server is unknown. Check Webmin and if + the problem persists, contact Technical Support. + 2: Restart the StruxureWare DC Operation server. If the server was part of + a cluster, see the StruxureWare DC Operation User Assistance about + rejoining the cluster. If the problem persists, contact Technical Support. + 3: No problem. + 4: High availability is lost. The StruxureWare DC Operation Application + server is running but one or more nodes are not available. If the + StruxureWare DC Operation server is part of a cluster, ensure all nodes + are running and there is a network connection between the nodes. If the + problem persists, contact Technical Support. + 5: Wait for the StruxureWare DC Operation Application server to initialize. + If the problem persists, contact Technical Support. + 6: Wait for the StruxureWare DC Operation Application server to finish + starting. + If the problem persists, contact Technical Support. + 7: This node is running in Disaster Recovery mode. + 8: The JBoss postoffice is currently inconsistent. This may be a temporary + issue. If the problem persists for more than 10 minutes, + contact Technical Support. + 9: The JBoss is missing jgroups. This may be a temporary issue. If the + problem persists for more than 10 minutes, contact Technical Support." + ::= { struxureWareOperationsStatus 1 } + +databaseStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + stopped(2), + running(3), + detached(4), + catching-up(5), + attaching(6), + running-master(7), + running-primary-slave(8), + running-slave(9), + running-alone(10) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the StruxureWare Operations database: + 1: The status of the database is unknown. Check Webmin and if the problem + persists, contact Technical Support. + 2: Restart the StruxureWare DC Operation server. If the server was part of + a cluster, see the StruxureWare DC Operation User Assistance about + rejoining the cluster. If the problem persists, contact Technical Support. + 3: No problem. + 4: High availability is lost. The database is detached from the cluster + and does not receive updates. See the StruxureWare DC Operation User + Assistance about reattaching the database node to the StruxureWare DC + Operation cluster. + If the problem persists, contact Technical Support. + 5: The database is catching up with the cluster. Wait for the StruxureWare + DC Operation database to retrieve all updates from the master node. + If the problem persists, contact Technical Support. + 6: The database is attaching to the cluster. Wait for the StruxureWare + Operation database to attach to the cluster. If the problem persists, + contact Technical Support. + 7: The database is the master in a cluster. + 8: The database is the primary slave in the cluster. All changes on master + are synchronously replicated to this node. + 9: The database is a secondary slave in the cluster. All changes on + master are asynchronously replicated to this node. + 10: The database does not replicate its changes to other nodes." + ::= { struxureWareOperationsStatus 2 } + +loadBalancerStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + stopped(2), + running(3), + running-missing(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the StruxureWare Operations load balancer: + 1: Load Balancer status is unknown. Check Webmin and if the problem + persists, contact Technical Support. + 2: Load Balancer stopped. Restart the StruxureWare DC Operation server. + If the problem persists, contact Technical Support. + 3: Normal status + 4: High availability is lost. The StruxureWare DC Operation Load Balancer + is running but one or more nodes are not available. If the StruxureWare DC + Operation server is part of a cluster, ensure all nodes are running and + there is a network connection between the nodes. If the problem persists, + contact Technical Support." + ::= { struxureWareOperationsStatus 3 } + +essentialServicesStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + stopped(2), + running(3), + time-sync-problems(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the StruxureWare Operations essential services: + 1: Unknown status. Check Webmin and if the problem persists, contact + Technical Support. + 2: Essential services are not running on the StruxureWare DC Operation + server. Reboot the node and monitor the status page in Webmin. If the + problem persists, contact Technical Support. + 3: Normal status + 4: The time difference between the StruxureWare DC Operation slave and the + master node is too big. Correct the time on the slave to match the time on + the master. Consider using an NTP server. If the problem persists, + contact Technical Support." + ::= { struxureWareOperationsStatus 4 } + +-- the ups group +-- the upsIdent group +-- the upsBasicIdent + +upsBasicIdentModel OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The UPS model name (e.g. 'APC Smart-UPS 600')." + ::= { upsBasicIdent 1 } + +upsBasicIdentName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "An 8 byte ID string identifying the UPS. This object + can be set by the administrator." + ::= { upsBasicIdent 2 } + + +-- the upsAdvIdent group + +upsAdvIdentFirmwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of the UPS system's microprocessor." + ::= { upsAdvIdent 1 } + +upsAdvIdentDateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date when the UPS was manufactured in mm/dd/yy (or yyyy) format." + ::= { upsAdvIdent 2 } + +upsAdvIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An 8-character string identifying the serial number of + the UPS internal microprocessor. This number is set at + the factory. NOTE: This number does NOT correspond to + the serial number on the rear of the UPS." + ::= { upsAdvIdent 3 } + +upsAdvIdentFirmwareRevision2 OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of a UPS system co-microprocessor." + ::= { upsAdvIdent 4 } + +upsAdvIdentSkuNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The SKU number of a UPS system." + ::= { upsAdvIdent 5 } + + +-- the upsBattery group +-- the upsBasicBattery group + +upsBasicBatteryStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + batteryNormal(2), + batteryLow(3), + batteryInFaultCondition(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the UPS batteries. A batteryLow(3) value + indicates the UPS will be unable to sustain the current + load, and its services will be lost if power is not restored. + The amount of run time in reserve at the time of low battery + can be configured by the upsAdvConfigLowBatteryRunTime. + A batteryInFaultCondition(4)value indicates that a battery + installed has an internal error condition." + ::= { upsBasicBattery 1 } + +upsBasicBatteryTimeOnBattery OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The elapsed time since the UPS has switched to battery + power." + ::= { upsBasicBattery 2 } + +upsBasicBatteryLastReplaceDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The date when the UPS system's batteries were last replaced + in mm/dd/yy (or yyyy) format. For Smart-UPS models, this value + is originally set in the factory. When the UPS batteries + are replaced, this value should be reset by the administrator. + For Symmetra PX 250/500 this OID is read only and is configurable in the local display only." + ::= { upsBasicBattery 3 } + +-- the upsAdvBattery group + +upsAdvBatteryCapacity OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The remaining battery capacity expressed in + percent of full capacity." + ::= { upsAdvBattery 1 } + +upsAdvBatteryTemperature OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current internal UPS temperature expressed in + Celsius." + ::= { upsAdvBattery 2 } + +upsAdvBatteryRunTimeRemaining OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The UPS battery run time remaining before battery + exhaustion." + ::= { upsAdvBattery 3 } + +upsAdvBatteryReplaceIndicator OBJECT-TYPE + SYNTAX INTEGER { + noBatteryNeedsReplacing(1), + batteryNeedsReplacing(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether the UPS batteries need replacing." + ::= { upsAdvBattery 4 } + +upsAdvBatteryNumOfBattPacks OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of external battery packs connected to the UPS. If + the UPS does not use smart cells then the agent reports + ERROR_NO_SUCH_NAME." + ::= { upsAdvBattery 5 } + +upsAdvBatteryNumOfBadBattPacks OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of external battery packs connected to the UPS that + are defective. If the UPS does not use smart cells then the + agent reports ERROR_NO_SUCH_NAME." + ::= { upsAdvBattery 6 } + +upsAdvBatteryNominalVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal battery voltage in Volts." + ::= { upsAdvBattery 7 } + +upsAdvBatteryActualVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual battery bus voltage in Volts." + ::= { upsAdvBattery 8 } + +upsAdvBatteryCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery current in Amps." + ::= { upsAdvBattery 9 } + +upsAdvTotalDCCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total DC current in Amps." + ::= { upsAdvBattery 10 } + +upsAdvBatteryFullCapacity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The full chargeable capacity of the battery which is + expressed in percentage." + ::= { upsAdvBattery 11 } + +-- Advanced Battery Voltage Table + + upsAdvBatteryActualVoltageTable OBJECT-TYPE + SYNTAX SEQUENCE OF UPSAdvBatteryActualVoltageEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of battery table entries. The number of battery + frames present in UPS." + ::= { upsAdvBattery 12 } + + + upsAdvBatteryActualVoltageEntry OBJECT-TYPE + SYNTAX UPSAdvBatteryActualVoltageEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Information applicable to + each of the Battery frames." + INDEX { upsAdvBatteryActualVoltageTableIndex } + ::= { upsAdvBatteryActualVoltageTable 1 } + + UPSAdvBatteryActualVoltageEntry ::= SEQUENCE { + upsAdvBatteryActualVoltageTableIndex INTEGER, + upsAdvBatteryActualVoltagePolarity INTEGER, + upsAdvBatteryFrameActualVoltage INTEGER + } + + upsAdvBatteryActualVoltageTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Battery Frame identifier. Battery Frame index." + ::= { upsAdvBatteryActualVoltageEntry 1 } + + upsAdvBatteryActualVoltagePolarity OBJECT-TYPE + SYNTAX INTEGER { + positive (0), + negative (1) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The selected Battery Voltage Polarity. + 0 indicates positive polarity. + 1 indicates negative polarity." + ::= { upsAdvBatteryActualVoltageEntry 2 } + + upsAdvBatteryFrameActualVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual battery bus voltage in Volts." + ::= { upsAdvBatteryActualVoltageEntry 3 } + +-- Advanced TotalDC Current Table + + upsAdvTotalDCCurrentTable OBJECT-TYPE + SYNTAX SEQUENCE OF UPSAdvTotalDCCurrentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of Battery Frame table entries. The number of entries + is given by the value of Number of Battery Frames." + ::= { upsAdvBattery 13 } + + + upsAdvTotalDCCurrentEntry OBJECT-TYPE + SYNTAX UPSAdvTotalDCCurrentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular Battery Frame." + INDEX { upsAdvTotalDCCurrentTableIndex } + ::= { upsAdvTotalDCCurrentTable 1 } + + UPSAdvTotalDCCurrentEntry ::= SEQUENCE { + upsAdvTotalDCCurrentTableIndex INTEGER, + upsAdvTotalDCCurrentPolarity INTEGER, + upsAdvTotalFrameDCCurrent INTEGER + } + + upsAdvTotalDCCurrentTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Battery Frame identifier. Total DC Current + Table Index." + ::= { upsAdvTotalDCCurrentEntry 1 } + + upsAdvTotalDCCurrentPolarity OBJECT-TYPE + SYNTAX INTEGER { + positive (0), + negative (1) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The selected Battery Current Polarity. + 0 indicates positive polarity. + 1 indicates negative polarity." + ::= { upsAdvTotalDCCurrentEntry 2 } + + upsAdvTotalFrameDCCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + " The Total DC Current of battery in Amperes." + ::= { upsAdvTotalDCCurrentEntry 3 } + + + +-- Advanced Battery Current Table + + upsAdvBatteryCurrentTable OBJECT-TYPE + SYNTAX SEQUENCE OF UPSAdvBatteryCurrentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of Battery Frame table entries. The number of entries + is given by number of Battery frames present." + ::= { upsAdvBattery 14 } + + upsAdvBatteryCurrentEntry OBJECT-TYPE + SYNTAX UPSAdvBatteryCurrentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular battery frame." + INDEX { upsAdvBatteryCurrentTableIndex, upsAdvBatteryCurrentIndex } + ::= { upsAdvBatteryCurrentTable 1 } + + UPSAdvBatteryCurrentEntry ::= SEQUENCE { + upsAdvBatteryCurrentTableIndex INTEGER, + upsAdvBatteryCurrentIndex INTEGER, + upsAdvBatteryCurrentPolarity INTEGER, + upsAdvBatteryFrameCurrent INTEGER + } + + upsAdvBatteryCurrentTableIndex OBJECT-TYPE + SYNTAX INTEGER + + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Battery Frame identifier. Battery Current + Table Index." + ::= { upsAdvBatteryCurrentEntry 1 } + + upsAdvBatteryCurrentIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery frame identifier." + ::= { upsAdvBatteryCurrentEntry 2 } + + upsAdvBatteryCurrentPolarity OBJECT-TYPE + SYNTAX INTEGER { + positive (0), + negative (1) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The selected Battery current polarity. + 0 indicates positive polarity. + 1 indicates negative polarity" + ::= { upsAdvBatteryCurrentEntry 3 } + + upsAdvBatteryFrameCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Battery current measured in Amperes" + ::= { upsAdvBatteryCurrentEntry 4 } + + + upsAdvBatteryEstimatedChargeTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The estimated remaining time required to charge the UPS to a full state of charge." + ::= { upsAdvBattery 15 } + + upsAdvBatteryPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The measured battery power in kW." + ::= { upsAdvBattery 16 } + + upsAdvBatteryChargerStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + ok(2), + inFaultCondition(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the battery charger. If the UPS is unable + to find the state of charger, this variable is set to unknown(1)." + ::= { upsAdvBattery 17 } + + + upsAdvBatteryInternalSKU OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The SKU of the internal battery." + ::= { upsAdvBattery 19 } + + upsAdvBatteryExternalSKU OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The SKU of the external battery." + ::= { upsAdvBattery 20 } + + upsAdvBatteryRecommendedReplaceDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The recommended replacement date for the battery based on the UPS internal battery life algorithm." + ::= { upsAdvBattery 21 } + + +-- the upsHighPrecBattery group + +upsHighPrecBatteryCapacity OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The remaining battery capacity expressed in + tenths of percent of full capacity." + ::= { upsHighPrecBattery 1 } + +upsHighPrecBatteryTemperature OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current internal UPS temperature expressed in + tenths of degrees Celsius." + ::= { upsHighPrecBattery 2 } + +upsHighPrecBatteryNominalVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal battery voltage in tenths of Volts." + ::= { upsHighPrecBattery 3 } + +upsHighPrecBatteryActualVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual battery bus voltage in tenths of Volts." + ::= { upsHighPrecBattery 4 } + +upsHighPrecBatteryCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery current in tenths of Amps." + ::= { upsHighPrecBattery 5 } + +upsHighPrecTotalDCCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total DC current in tenths of Amps." + ::= { upsHighPrecBattery 6 } + + + + +-- High Precision Actual Battery Voltage Table + + upsHighPrecBatteryActualVoltageTable OBJECT-TYPE + SYNTAX SEQUENCE OF UPSHighPrecBatteryActualVoltageEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of Battery frame table entries. The number of entries + is given by the number of Battery frames." + ::= { upsHighPrecBattery 7 } + + + upsHighPrecBatteryActualVoltageEntry OBJECT-TYPE + SYNTAX UPSHighPrecBatteryActualVoltageEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular battery frame." + INDEX { upsHighPrecBatteryActualVoltageTableIndex } + ::= { upsHighPrecBatteryActualVoltageTable 1 } + + UPSHighPrecBatteryActualVoltageEntry ::= SEQUENCE { + upsHighPrecBatteryActualVoltageTableIndex INTEGER, + upsHighPrecBatteryActualVoltagePolarity INTEGER, + upsHighPrecBatteryVoltage INTEGER + } + + upsHighPrecBatteryActualVoltageTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Battery Frame identifier. High Precision + Actual Voltage Table Index." + ::= { upsHighPrecBatteryActualVoltageEntry 1 } + + upsHighPrecBatteryActualVoltagePolarity OBJECT-TYPE + SYNTAX INTEGER { + positive (0), + negative (1) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The selected Battery Voltage polarity. + 0 indicates positive polarity. + 1 indicates negative polarity." + ::= { upsHighPrecBatteryActualVoltageEntry 2 } + + upsHighPrecBatteryVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual battery bus voltage expressed + as tenths of Volts. " + ::= { upsHighPrecBatteryActualVoltageEntry 3 } + +-- High Precision Total DC Current Table + + upsHighPrecTotalDCCurrentTable OBJECT-TYPE + SYNTAX SEQUENCE OF UPSHighPrecTotalDCCurrentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of Battery Frame table entries. The number of entries + is given by the number of battery frames." + ::= { upsHighPrecBattery 8 } + + + upsHighPrecTotalDCCurrentEntry OBJECT-TYPE + SYNTAX UPSHighPrecTotalDCCurrentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular battery frame." + INDEX { upsHighPrecTotalDCCurrentTableIndex } + ::= { upsHighPrecTotalDCCurrentTable 1 } + + UPSHighPrecTotalDCCurrentEntry ::= SEQUENCE { + upsHighPrecTotalDCCurrentTableIndex INTEGER, + upsHighPrecTotalDCCurrentPolarity INTEGER, + upsHighPrecTotalDCFrameCurrent INTEGER + } + + upsHighPrecTotalDCCurrentTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Battery Frame identifier. + High precision Total DC Current index." + ::= { upsHighPrecTotalDCCurrentEntry 1 } + + upsHighPrecTotalDCCurrentPolarity OBJECT-TYPE + SYNTAX INTEGER { + positive (0), + negative (1) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The selected Battery Current polarity. + 0 indicates positive polarity. + 1 indicates negative polarity." + ::= { upsHighPrecTotalDCCurrentEntry 2 } + + upsHighPrecTotalDCFrameCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total DC current in tenths of Amperes. " + ::= { upsHighPrecTotalDCCurrentEntry 3 } + + +-- HighPrec Battery Current Table + + upsHighPrecBatteryCurrentTable OBJECT-TYPE + SYNTAX SEQUENCE OF UPSHighPrecBatteryCurrentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of Battery Frame table entries. The number of entries + is given by the number of battery frames." + ::= { upsHighPrecBattery 9 } + + upsHighPrecBatteryCurrentEntry OBJECT-TYPE + SYNTAX UPSHighPrecBatteryCurrentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular battery frame." + INDEX { upsHighPrecBatteryCurrentTableIndex, upsHighPrecBatteryCurrentIndex } + ::= { upsHighPrecBatteryCurrentTable 1 } + + UPSHighPrecBatteryCurrentEntry ::= SEQUENCE { + upsHighPrecBatteryCurrentTableIndex INTEGER, + upsHighPrecBatteryCurrentIndex INTEGER, + upsHighPrecBatteryCurrentPolarity INTEGER, + upsHighPrecBatteryFrameCurrent INTEGER + } + + upsHighPrecBatteryCurrentTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Battery frame identifier. + Battery Frame index." + ::= { upsHighPrecBatteryCurrentEntry 1 } + + upsHighPrecBatteryCurrentIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Battery frame identifier. + Battery Index for each frame." + ::= { upsHighPrecBatteryCurrentEntry 2 } + + upsHighPrecBatteryCurrentPolarity OBJECT-TYPE + SYNTAX INTEGER { + positive (0), + negative (1) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The selected Battery Current polarity. + 0 indicates positive polarity. + 1 indicates negative polarity." + ::= { upsHighPrecBatteryCurrentEntry 3 } + + upsHighPrecBatteryFrameCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Battery current in tenths of Amperes." + ::= { upsHighPrecBatteryCurrentEntry 4 } + +-- High Precision Battery Packs + +upsHighPrecBatteryPacks OBJECT IDENTIFIER ::= { upsHighPrecBattery 10 } + +upsHighPrecBatteryPackTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the upsHighPrecBatteryPacks." + ::= { upsHighPrecBatteryPacks 1 } + + upsHighPrecBatteryPackTable OBJECT-TYPE + SYNTAX SEQUENCE OF UPSHighPrecBatteryPackEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of Battery Pack table entries. The number of entries + is given by number of Battery Packs present." + ::= { upsHighPrecBatteryPacks 2 } + + upsHighPrecBatteryPackEntry OBJECT-TYPE + SYNTAX UPSHighPrecBatteryPackEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular battery pack." + INDEX { upsHighPrecBatteryPackIndex, upsHighPrecBatteryCartridgeIndex } + ::= { upsHighPrecBatteryPackTable 1 } + + UPSHighPrecBatteryPackEntry ::= SEQUENCE { + upsHighPrecBatteryPackIndex INTEGER, + upsHighPrecBatteryCartridgeIndex INTEGER, + upsHighPrecBatteryPackFirmwareRevision DisplayString, + upsHighPrecBatteryPackSerialNumber DisplayString, + upsHighPrecBatteryPackTemperature INTEGER, + upsHighPrecBatteryPackStatus OCTET STRING, + upsHighPrecBatteryPackCartridgeHealth OCTET STRING, + upsHighPrecBatteryPackCartridgeReplaceDate DisplayString, + upsHighPrecBatteryPackCartridgeInstallDate DisplayString, + upsHighPrecBatteryPackCartridgeStatus OCTET STRING + } + + upsHighPrecBatteryPackIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery pack identifier." + ::= { upsHighPrecBatteryPackEntry 1 } + + upsHighPrecBatteryCartridgeIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery cartridge identifier." + ::= { upsHighPrecBatteryPackEntry 2 } + + upsHighPrecBatteryPackFirmwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery pack firmware revision." + ::= { upsHighPrecBatteryPackEntry 3} + + upsHighPrecBatteryPackSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery pack serial number." + ::= { upsHighPrecBatteryPackEntry 4} + + upsHighPrecBatteryPackTemperature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery pack temperature measured in 10ths of degree Celcius" + ::= { upsHighPrecBatteryPackEntry 5 } + + upsHighPrecBatteryPackStatus OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery status for the pack only. + bit 0 Disconnected + bit 1 Overvoltage + bit 2 NeedsReplacement + bit 3 OvertemperatureCritical + bit 4 Charger + bit 5 TemperatureSensor + bit 6 BusSoftStart + bit 7 OvertemperatureWarning + bit 8 GeneralError + bit 9 Communication + bit 10 DisconnectedFrame + bit 11 FirmwareMismatch + " + ::= { upsHighPrecBatteryPackEntry 6 } + + upsHighPrecBatteryPackCartridgeHealth OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery cartridge health. + bit 0 Battery lifetime okay + bit 1 Battery lifetime near end, order replacement cartridge + bit 2 Battery lifetime exceeded, replace battery + bit 3 Battery lifetime near end acknowledged, order replacement cartridge + bit 4 Battery lifetime exceeded acknowledged, replace battery + bit 5 Battery measured lifetime near end, order replacement cartridge + bit 6 Battery measured lifetime near end acknowledged, order replacement cartridge + " + ::= { upsHighPrecBatteryPackEntry 7} + + upsHighPrecBatteryPackCartridgeReplaceDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery cartridge estimated battery replace date." + ::= { upsHighPrecBatteryPackEntry 8 } + + upsHighPrecBatteryPackCartridgeInstallDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The battery cartridge install date." + ::= { upsHighPrecBatteryPackEntry 9 } + + upsHighPrecBatteryPackCartridgeStatus OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery cartridge status. + bit 0 Disconnected + bit 1 Overvoltage + bit 2 NeedsReplacement + bit 3 OvertemperatureCritical + bit 4 Charger + bit 5 TemperatureSensor + bit 6 BusSoftStart + bit 7 OvertemperatureWarning + bit 8 GeneralError + bit 9 Communication + bit 10 DisconnectedFrame + bit 11 FirmwareMismatch + " + ::= { upsHighPrecBatteryPackEntry 10 } + +-- the upsBasicInput group + +upsBasicInputPhase OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current AC input phase." + ::= { upsBasicInput 1 } + + +-- the upsAdvInput group + +upsAdvInputLineVoltage OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current utility line voltage in VAC." + ::= { upsAdvInput 1 } + +upsAdvInputMaxLineVoltage OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum utility line voltage in VAC over the + previous 1 minute period." + ::= { upsAdvInput 2 } + +upsAdvInputMinLineVoltage OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum utility line voltage in VAC over the + previous 1 minute period." + ::= { upsAdvInput 3 } + +upsAdvInputFrequency OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current input frequency to the UPS system in Hz." + ::= { upsAdvInput 4 } + + +upsAdvInputLineFailCause OBJECT-TYPE + SYNTAX INTEGER { + noTransfer(1), + highLineVoltage(2), + brownout(3), + blackout(4), + smallMomentarySag(5), + deepMomentarySag(6), + smallMomentarySpike(7), + largeMomentarySpike(8), + selfTest(9), + rateOfVoltageChange(10) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The reason for the occurrence of the last transfer to UPS + battery power. The variable is set to: + - noTransfer(1) -- if there is no transfer yet. + - highLineVoltage(2) -- if the transfer to battery is caused + by an over voltage greater than the high transfer voltage. + - brownout(3) -- if the duration of the outage is greater than + five seconds and the line voltage is between 40% of the + rated output voltage and the low transfer voltage. + - blackout(4) -- if the duration of the outage is greater than five + seconds and the line voltage is between 40% of the rated + output voltage and ground. + - smallMomentarySag(5) -- if the duration of the outage is less + than five seconds and the line voltage is between 40% of the + rated output voltage and the low transfer voltage. + - deepMomentarySag(6) -- if the duration of the outage is less + than five seconds and the line voltage is between 40% of the + rated output voltage and ground. The variable is set to + - smallMomentarySpike(7) -- if the line failure is caused by a + rate of change of input voltage less than ten volts per cycle. + - largeMomentarySpike(8) -- if the line failure is caused by + a rate of change of input voltage greater than ten volts per cycle. + - selfTest(9) -- if the UPS was commanded to do a self test. + - rateOfVoltageChange(10) -- if the failure is due to the rate of change of + the line voltage." + ::= { upsAdvInput 5 } + + +upsAdvInputNominalFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal input frequency of the UPS system in Hz." + ::= { upsAdvInput 6 } + +upsAdvInputNominalVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal input voltage of the UPS system in VAC." + ::= { upsAdvInput 7 } + +upsAdvInputBypassNominalFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal bypass input frequency of the UPS system in Hz." + ::= { upsAdvInput 8 } + +upsAdvInputBypassNominalVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal bypass input voltage of the UPS system in VAC." + ::= { upsAdvInput 9 } + + upsAdvInputStatisticsTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsAdvInputStatisticsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of input table entries. The number of entries + is given by the value of upsPhaseNumInputs." + ::= { upsAdvInput 10 } + + upsAdvInputStatisticsEntry OBJECT-TYPE + SYNTAX UpsAdvInputStatisticsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular input." + INDEX { upsAdvInputStatisticsIndex } + ::= { upsAdvInputStatisticsTable 1 } + +UpsAdvInputStatisticsEntry ::= SEQUENCE { + upsAdvInputStatisticsIndex INTEGER, + upsAdvInputApparentPower INTEGER, + upsAdvInputVoltageTHD INTEGER, + upsAdvInputBypassVoltageTHD INTEGER, + upsAdvInputPeakCurrent INTEGER, + upsAdvInputBypassPeakCurrent INTEGER, + upsAdvInputActivePower INTEGER + } + + upsAdvInputStatisticsIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input identifier." + ::= { upsAdvInputStatisticsEntry 1 } + +upsAdvInputApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input apparent power(sum of all of the three phases) measured in kVA." + ::= { upsAdvInputStatisticsEntry 2 } + +upsAdvInputVoltageTHD OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input voltage Total Harmonic Distortion in percent." + ::= { upsAdvInputStatisticsEntry 3 } + +upsAdvInputBypassVoltageTHD OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The bypass input voltage Total Harmonic Distortion in percent." + ::= { upsAdvInputStatisticsEntry 4 } + +upsAdvInputPeakCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input peak current in Amperes." + ::= { upsAdvInputStatisticsEntry 5 } + +upsAdvInputBypassPeakCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The bypass input peak current in Amperes." + ::= { upsAdvInputStatisticsEntry 6 } + + +upsAdvInputActivePower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input active power measured in kW." + ::= { upsAdvInputStatisticsEntry 7 } + + + + +upsAdvInputTotalApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input total apparent power(sum of all three phases) + of the UPS system in kVA." + ::= { upsAdvInput 11 } + +upsAdvInputTotalActivePower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input total active power(sum of all three phases) + of the UPS system in kW." + ::= { upsAdvInput 12 } + +upsAdvInputBypassTotalApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input bypass total apparent power(sum of all three phases) + of the UPS system in kVA." + ::= { upsAdvInput 13 } + +upsAdvInputBypassTotalActivePower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input bypass total active power(sum of all three phases) + of the UPS system in kW." + ::= { upsAdvInput 14 } + + +-- the upsHighPrecInput group + +upsHighPrecInputLineVoltage OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current utility line voltage in tenths of VAC." + ::= { upsHighPrecInput 1 } + +upsHighPrecInputMaxLineVoltage OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum utility line voltage in tenths of VAC over the + previous 1 minute period." + ::= { upsHighPrecInput 2 } + +upsHighPrecInputMinLineVoltage OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum utility line voltage in tenths of VAC over the + previous 1 minute period." + ::= { upsHighPrecInput 3 } + +upsHighPrecInputFrequency OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current input frequency to the UPS system in tenths of Hz." + ::= { upsHighPrecInput 4 } + + +upsHighPrecInputEnergyUsage OBJECT-TYPE + SYNTAX Unsigned32 + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input energy usage of the UPS in hundredths of kWh." + ::= { upsHighPrecInput 5 } + +upsHighPrecInputBypassVoltage OBJECT-TYPE + SYNTAX Unsigned32 + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current bypass line voltage in tenths of VAC." + ::= { upsHighPrecInput 6 } + +upsHighPrecInputBypassFrequency OBJECT-TYPE + SYNTAX Unsigned32 + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current input bypass frequency to the UPS system in tenths of Hz." + ::= { upsHighPrecInput 7 } + +-- the upsBasicOutput group + +upsBasicOutputStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + onLine(2), + onBattery(3), + onSmartBoost(4), + timedSleeping(5), + softwareBypass(6), + off(7), + rebooting(8), + switchedBypass(9), + hardwareFailureBypass(10), + sleepingUntilPowerReturn(11), + onSmartTrim(12), + ecoMode(13), + hotStandby(14), + onBatteryTest(15), + emergencyStaticBypass(16), + staticBypassStandby(17), + powerSavingMode(18), + spotMode(19), + eConversion(20) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current state of the UPS. If the UPS is unable to + determine the state of the UPS this variable is set + to unknown(1)." + ::= { upsBasicOutput 1 } + +upsBasicOutputPhase OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current output phase." + ::= { upsBasicOutput 2 } + +upsBasicSystemStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + onLine(2), + onBattery(3), + onSmartBoost(4), + timedSleeping(5), + softwareBypass(6), + off(7), + rebooting(8), + switchedBypass(9), + hardwareFailureBypass(10), + sleepingUntilPowerReturn(11), + onSmartTrim(12), + ecoMode(13), + inverter(14), + eConversion(15) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Current state for the whole system (UPS and surrounding breakers). + If the UPS is unable to determine the state of the system, this + variable is set to unknown(1)." + ::= { upsBasicOutput 3 } + +upsBasicSystemInternalTemperature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual internal temperature of the UPS system in Celsius." + ::= { upsBasicOutput 4 } + + + upsBasicSystemInverterStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + ok(2), + inFaultCondition(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current state of the UPS inverter. If the UPS is unable + to determine the state of the inverter, this variable is set + to unknown(1)." + ::= { upsBasicOutput 5 } + + upsBasicSystemPFCStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + ok(2), + inFaultCondition(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The general status of the power factor correction (AC input stage + of the UPS). If the UPS is unable to determine the state of PFC, + this variable is set to unknown(1)." + ::= { upsBasicOutput 6 } + + upsBasicOutputACwiringConfiguration OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + noNeutralWiredonSystem(2), + neutralUsedforSupplyingLoad(3) + + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates if neutral wire on output side of the UPS is + used (load wired line to neutral). If the UPS is unable to + determine the state of neutral, this variable is set to + unknown(1)." + ::= { upsBasicOutput 7 } + + + +-- the upsAdvOutput group + +upsAdvOutputVoltage OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output voltage of the UPS system in VAC." + ::= { upsAdvOutput 1 } + +upsAdvOutputFrequency OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current output frequency of the UPS system in Hz." + ::= { upsAdvOutput 2 } + +upsAdvOutputLoad OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current UPS load expressed in percent + of rated capacity." + ::= { upsAdvOutput 3 } + +upsAdvOutputCurrent OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current in amperes drawn by the load on the UPS." + ::= { upsAdvOutput 4 } + +upsAdvOutputRedundancy OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of power modules which can fail or be + removed without causing the UPS to generate a Minimum + Redundancy Lost event." + ::= { upsAdvOutput 5 } + +upsAdvOutputKVACapacity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum load that this UPS can support." + ::= { upsAdvOutput 6 } + +upsAdvOutputNominalFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal output frequency of the UPS system in Hz." + ::= { upsAdvOutput 7 } + +upsAdvOutputActivePower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total output active power of the UPS system in W. + The total active power is the sum of phase 1, phase 2 and + phase 3 power." + ::= { upsAdvOutput 8 } + +upsAdvOutputApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total output apparent power of all phases of the UPS system in VA." + ::= { upsAdvOutput 9 } + + + upsAdvOutputStatisticsTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsAdvOutputStatisticsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of input table entries. The number of entries + is given by the value of upsPhaseNumOutputs." + ::= { upsAdvOutput 10 } + + upsAdvOutputStatisticsEntry OBJECT-TYPE + SYNTAX UpsAdvOutputStatisticsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular output." + INDEX { upsAdvOutputStatisticsIndex } + ::= { upsAdvOutputStatisticsTable 1 } + + UpsAdvOutputStatisticsEntry ::= SEQUENCE { + upsAdvOutputStatisticsIndex INTEGER, + upsAdvOutputPeakCurrent INTEGER, + upsAdvOutputCurrentTHD INTEGER, + upsAdvOutputCrestFactor INTEGER + + } + + upsAdvOutputStatisticsIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output identifier." + ::= { upsAdvOutputStatisticsEntry 1 } + + upsAdvOutputPeakCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output peak current in Amperes." + ::= { upsAdvOutputStatisticsEntry 2 } + + upsAdvOutputCurrentTHD OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output current Total Harmonic Distortion in percent." + ::= { upsAdvOutputStatisticsEntry 3 } + + upsAdvOutputCrestFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output current crest factor expressed in tenths." + ::= { upsAdvOutputStatisticsEntry 4 } + + upsAdvOutputNeutralCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The neutral current in amperes." + ::= { upsAdvOutput 11 } + + +-- the upsHighPrecOutput group + +upsHighPrecOutputVoltage OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output voltage of the UPS system in tenths of VAC." + ::= { upsHighPrecOutput 1 } + +upsHighPrecOutputFrequency OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current output frequency of the UPS system in tenths of Hz." + ::= { upsHighPrecOutput 2 } + +upsHighPrecOutputLoad OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current UPS load expressed in tenths of percent + of rated capacity." + ::= { upsHighPrecOutput 3 } + +upsHighPrecOutputCurrent OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current in tenths of amperes drawn by the load on the UPS." + ::= { upsHighPrecOutput 4 } + +upsHighPrecOutputEfficiency OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The positive values represent efficiency of the UPS in tenths of percent. + -1 If UPS supports this OID but the result is not available + -2 Load is too low to report efficiency + -3 Output off and efficiency is 0 + -4 On battery, efficiency is not measured or calculated in this mode + -5 In Bypass, efficiency is not measured or calculated in this mode + -6 Battery charging, battery is charging and adversely affecting efficiency + -7 Poor AC input, the main input is outside the optimum efficiency range" + ::= { upsHighPrecOutput 5 } + +upsHighPrecOutputEnergyUsage OBJECT-TYPE + SYNTAX Unsigned32 + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output energy usage of the UPS in hundredths of kWh." + ::= { upsHighPrecOutput 6 } + +-- the upsBasicConfig group + +upsBasicConfigNumDevices OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of devices that are plugged into the UPS. + This value is customer configurable from the device entry table" + ::= { upsBasicConfig 1 } + +upsBasicConfigDeviceTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsBasicConfigDeviceEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of devices that are plugged into the UPS. + The number of entries is given by the value of + upsBasicConfigNumDevices." + ::= { upsBasicConfig 2 } + +upsBasicConfigDeviceEntry OBJECT-TYPE + SYNTAX UpsBasicConfigDeviceEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The devices plugged in to the UPS." + INDEX { deviceIndex } + ::= { upsBasicConfigDeviceTable 1 } + +UpsBasicConfigDeviceEntry ::= + SEQUENCE { + deviceIndex + INTEGER, + deviceName + DisplayString, + vaRating + INTEGER, + acceptThisDevice + INTEGER + } + +deviceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the device that is plugged into the UPS." + ::= { upsBasicConfigDeviceEntry 1 } + +deviceName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name/description of the device plugged into the UPS." + ::= { upsBasicConfigDeviceEntry 2 } + +vaRating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The volt-amp rating of the device plugged into the UPS." + ::= { upsBasicConfigDeviceEntry 3 } + +acceptThisDevice OBJECT-TYPE + SYNTAX INTEGER { + yes(1), + no(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "An entry is added if yes, the entry is deleted if no." + ::= { upsBasicConfigDeviceEntry 4 } + + + + +-- the upsAdvConfig group + +upsAdvConfigRatedOutputVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The nominal output voltage from the UPS in VAC. + + For a list of allowed values supported by your UPS model, + see the UPS User's Manual. + + If a value other than a supported value is provided in a + set request, the UPS interprets it as the next lower + acceptable value. If the provided value is lower than + the lowest acceptable value, the lowest acceptable + value is used." + ::= { upsAdvConfig 1 } + +upsAdvConfigHighTransferVolt OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum line voltage in VAC allowed before the + UPS system transfers to battery backup. + + For a list of allowed values supported by your UPS model, + see the UPS User's Manual. + + If a value other than a supported value is provided in a + set request, the UPS interprets it as a the next higher + acceptable value. If the provided value is higher than + the highest acceptable value, the highest acceptable + value is used." + ::= { upsAdvConfig 2 } + +upsAdvConfigLowTransferVolt OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The minimum line voltage in VAC allowed before the + UPS system transfers to battery backup. + + For a list of allowed values supported by your UPS model, + see the UPS User's Manual. + + If a value other than a supported value is provided in a + set request, the UPS interprets it as the next lower + acceptable value. If the provided value is lower than + the lowest acceptable value, the lowest acceptable + value is used." + ::= { upsAdvConfig 3 } + +upsAdvConfigAlarm OBJECT-TYPE + SYNTAX INTEGER { + timed(1), + atLowBattery(2), + never(3), + mute(4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A flag indicating how the UPS should handle audible + line fail alarms: + timed(1): UPS alarm will sound after a preset timed duration starting + from the line fail condition (see OID upsAdvConfigAlarmTimer for the + alarm timer value) + atLowBattery(2): UPS alarm will sound when the UPS has reached a Low + Battery condition during a line fail + never(3): Disables the UPS audible alarm + mute(4): Mutes the current alarm for some UPSs only when it is in an + alarm state and will return to the previously configured option when + the UPS recovers from the alarm condition" + ::= { upsAdvConfig 4 } + +upsAdvConfigAlarmTimer OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The time after initial line failure at which the UPS + begins emitting audible alarms (beeping). This timer is + observed only if the value of extControlAlarm is timed(2). + Allowed values are 0 or 30 seconds. + + If a value other than a supported value is provided in a + set request, the UPS interprets it as a the next lower + acceptable value. If the provided value is lower than + the lowest acceptable value, the lowest acceptable + value is used." + ::= { upsAdvConfig 5 } + +upsAdvConfigMinReturnCapacity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The minimum battery capacity required before the UPS will + return from a low battery shutdown condition. The capacity is + measured from 0% battery capacity (or Low Battery) as a percent + of full capacity (100%). In other words, the UPS will not re-energize + the output until the battery has charged so that its' capacity is equal + to this value. + + For a list of allowed values supported by your UPS model, + see the UPS User's Manual. + + If a value other than a supported value is provided in a + set request, the UPS interprets it as a the next higher + acceptable value. If the provided value is higher than + the highest acceptable value, the highest acceptable + value is used." + ::= { upsAdvConfig 6 } + +upsAdvConfigSensitivity OBJECT-TYPE + SYNTAX INTEGER { + auto(1), + low(2), + medium(3), + high(4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The sensitivity of the UPS to utility line abnormalities + or noises." + ::= { upsAdvConfig 7 } + +upsAdvConfigLowBatteryRunTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The desired run time of the UPS, in seconds, once the + low battery condition is reached. During this time the UPS will + produce a constant warning tone which can not be disabled. + + For a list of allowed values supported by your UPS model, + see the UPS User's Manual. + + If a value other than a supported value is provided in a set + request, the UPS interprets the value as the next higher + acceptable value. If the provided value is higher than the + highest acceptable value, the highest acceptable value is used." + ::= { upsAdvConfig 8 } + +upsAdvConfigReturnDelay OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The delay in seconds after utility line power returns + before the UPS will turn on. This value is also used + when the UPS comes out of a reboot and before the UPS + wakes up from 'sleep' mode. + + For a list of allowed values supported by your UPS model, + see the UPS User's Manual. + + If a value other than a supported value is provided in a + set request, the UPS interprets it as a the next higher + acceptable value. If the provided value is higher than + the highest acceptable value, the highest acceptable + value is used." + ::= { upsAdvConfig 9 } + +upsAdvConfigShutoffDelay OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The delay in seconds the UPS remains on after being told + to turn off. + + For a list of allowed values supported by your UPS model, + see the UPS User's Manual. + + If a value other than a supported value is provided in a + set request, the UPS interprets it as a the next higher + acceptable value. If the provided value is higher than + the highest acceptable value, the highest acceptable + value is used." + ::= { upsAdvConfig 10 } + +upsAdvConfigUpsSleepTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The time in seconds for the UPS to go to 'sleep' when + instructed. When in sleep mode, the UPS will not provide + output power regardless of the input line state. Once the + specified time has elapsed, output power will be restored. + + This is a configuration setting. The UPS will not go to + sleep until told to do so by the manager from a management + station. + + Any input value is allowed, however the UPS only recognizes + 1/10 of an hour increments. The provided value will be + rounded to the closest 1/10 of an hour with one exception: + Any value entered between 1 and 540 seconds will be rounded + to 360 seconds (or 6 minutes)." + ::= { upsAdvConfig 11 } + + +upsAdvConfigSetEEPROMDefaults OBJECT-TYPE + SYNTAX INTEGER { + noSetEEPROMDefaults(1), + setEEPROMDefaults(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "WRITE: Resets the UPS EEPROM variables to default values. + READ: returns 0" + ::= { upsAdvConfig 12 } + +upsAdvConfigDipSwitchTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsAdvConfigDipSwitchEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Current settings of UPS dip switches." + ::= { upsAdvConfig 13 } + +upsAdvConfigDipSwitchEntry OBJECT-TYPE + SYNTAX UpsAdvConfigDipSwitchEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The current setting of one dip switch." + INDEX { dipSwitchIndex } + ::= { upsAdvConfigDipSwitchTable 1 } + +UpsAdvConfigDipSwitchEntry ::= + SEQUENCE { + dipSwitchIndex + INTEGER, + dipSwitchStatus + INTEGER + } + +dipSwitchIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of a UPS dip switch." + ::= { upsAdvConfigDipSwitchEntry 1 } + +dipSwitchStatus OBJECT-TYPE + SYNTAX INTEGER { + on(1), + off(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The setting of a UPS dip switch." + ::= { upsAdvConfigDipSwitchEntry 2 } + +upsAdvConfigBattExhaustThresh OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of seconds prior to battery exhaustion when the + UPS will switch off power to its load." + ::= { upsAdvConfig 14 } + +upsAdvConfigPassword OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The password entered at the UPS front panel to enable local + configuration of the EEProm. If the password is disabled or + is not supported, then the agent returns a null string." + ::= { upsAdvConfig 15 } + +upsAdvConfigAllowedSetTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsAdvConfigAllowedSetEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The table listing the allowed values for all discrete + configurable UPS variables." + ::= { upsAdvConfig 16 } + +upsAdvConfigAllowedSetEntry OBJECT-TYPE + SYNTAX UpsAdvConfigAllowedSetEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The table entry for a configurable UPS variable." + INDEX { apcUpsConfigFieldIndex } + ::= { upsAdvConfigAllowedSetTable 1 } + +UpsAdvConfigAllowedSetEntry ::= SEQUENCE { + apcUpsConfigFieldIndex INTEGER, + apcUpsConfigFieldOID OBJECT IDENTIFIER, + apcUpsConfigFieldValueRange DisplayString + } + +apcUpsConfigFieldIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to an eeprom field entry." + ::= { upsAdvConfigAllowedSetEntry 1 } + +apcUpsConfigFieldOID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The OID of the current configurable value." + ::= { upsAdvConfigAllowedSetEntry 2 } + +apcUpsConfigFieldValueRange OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The discrete set of allowed values of a configurable + register. Individual values are delimited by a comma." + ::= { upsAdvConfigAllowedSetEntry 3 } + +upsAdvConfigBattCabAmpHour OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure the amp-hour setting of the UPS battery cabinet." + ::= { upsAdvConfig 17 } + +upsAdvConfigPositionSelector OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + rack (2), + tower (3) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure UPS position selector. If the UPS doesn't + support this configuration it will report unknown (1). + The positions are either rack (2) for rack mounted or + tower (3) for tower unit." + ::= { upsAdvConfig 18 } + +upsAdvConfigOutputFreqRange OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + freqRangeAUTO (2), + freqRange60Var1 (3), + freqRange60Var3 (4), + freqRange50Var1 (5), + freqRange50Var3 (6), + freqRange60Var10 (7), + freqRange50Var10 (8), + freqRange60Var1dot0 (9), + freqRange50Var1dot0 (10), + freqRange50Pct0dot5 (11), + freqRange50Pct1 (12), + freqRange50Pct2 (13), + freqRange50Pct4 (14), + freqRange50Pct6 (15), + freqRange50Pct8 (16), + freqRange60Pct0dot5 (17), + freqRange60Pct1 (18), + freqRange60Pct2 (19), + freqRange60Pct4 (20), + freqRange60Pct6 (21), + freqRange60Pct8 (22) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure the output frequency tolerance range. + unknown(1) indicates the output frequency is unknown. + freqRangeAUTO(2) configure the output frequency range for automatic. + freqRange60Var1(3) configure the output frequency range for 60 +/- 0.1 Hz + freqRange60Var3(4) configure the output frequency range for 60 +/- 3.0 Hz + freqRange50Var1(5) configure the output frequency range for 50 +/- 0.1 Hz + freqRange50Var3(6) configure the output frequency range for 50 +/- 3.0 Hz + freqRange60Var10(7) configure the output frequency range for 60 +/- 10 Hz + freqRange50Var10(8) configure the output frequency range for 50 +/- 10 Hz + freqRange60Var1dot0(9) configure the output frequency range for 60 +/- 1.0 Hz + freqRange50Var1dot0(10) configure the output frequency range for 50 +/- 1.0 Hz + freqRange50Pct0dot5(11) configure the output frequency range for 50 Hz +/- 0.5 % + freqRange50Pct1(12) configure the output frequency range for 50 Hz +/- 1.0 % + freqRange50Pct2(13) configure the output frequency range for 50 Hz +/- 2.0 % + freqRange50Pct4(14) configure the output frequency range for 50 Hz +/- 4.0 % + freqRange50Pct6(15) configure the output frequency range for 50 Hz +/- 6.0 % + freqRange50Pct8(16) configure the output frequency range for 50 Hz +/- 8.0 % + freqRange60Pct0dot5(17) configure the output frequency range for 60 Hz +/- 0.5 % + freqRange60Pct1(18) configure the output frequency range for 60 Hz +/- 1.0 % + freqRange60Pct2(19) configure the output frequency range for 60 Hz +/- 2.0 % + freqRange60Pct4(20) configure the output frequency range for 60 Hz +/- 4.0 % + freqRange60Pct6(21) configure the output frequency range for 60 Hz +/- 6.0 % + freqRange60Pct8(22) configure the output frequency range for 60 Hz +/- 8.0 % + For a list of allowed values and conditions when variable can be set by your UPS model, + see the UPS User's Manual." + ::= { upsAdvConfig 19 } + +upsAdvConfigUPSFail OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + gotoBypass (2), + dropLoad (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure the UPS fail action. If UPS fails, + and frequency or voltage is out of range it will either + GotoBypass (2) or DropLoad (3). This OID will report + unknown (1) if it is not supported feature or option." + ::= { upsAdvConfig 20 } + +upsAdvConfigAlarmRedundancy OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure settings of UPS alarm if the redundancy is + under the current redundancy. Use 0 for never." + ::= { upsAdvConfig 21 } + +upsAdvConfigAlarmLoadOver OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure settings of UPS alarm if the load is + over the current load in kVA. Use -1 for never." + ::= { upsAdvConfig 22 } + +upsAdvConfigAlarmRuntimeUnder OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure settings of UPS alarm if the runtime is + under the current time of minutes. Use -1 for never." + ::= { upsAdvConfig 23 } + +upsAdvConfigVoutReporting OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + voutAUTO (2), + vout208 (3), + vout240 (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure the way the UPS scales its output voltage readings. + unknown(1) indicates the Vout Reporting is unknown. + voutAUTO(2) configure the Vout Reporting for automatic scaling. + vout208(3) configure the Vout Reporting for 208 Volts. + vout240(4) configure the Vout Reporting for 240 Volts." + ::= { upsAdvConfig 24 } + +upsAdvConfigNumExternalBatteries OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure the number of external batteries connected to the UPS." + ::= { upsAdvConfig 25 } + +upsAdvConfigSimpleSignalShutdowns OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure Simple Signal shutdown commands from the Simple Signal + port to be issued to the UPS. + unknown(1) indicates the Simple Signal Shutdown setting is unknown. + disabled(2) configure to disable Simple Signal Shutdowns. + enabled(3) configure to enable Simple Signal Shutdowns." + ::= { upsAdvConfig 26 } + +upsAdvConfigMaxShutdownTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum amount of time for server shutdown to complete before a + UPS shutdown occurs." + ::= { upsAdvConfig 27 } + +upsAsiUpsControlServerRequestShutdown OBJECT-TYPE + SYNTAX INTEGER { + serverShutdownOff (1), + serverShutdownReboot (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Start a server shutdown sequence: + serverShutdownOff: Shutdown server and turn off UPS + serverShutdownReboot: Shutdown server and turn reboot UPS." + ::= { upsAdvConfig 28 } + +upsAdvConfigMinReturnRuntime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The minimum amount of run time in seconds required before the output will be + turned on, using power calculation captured at start of last shutdown." + ::= { upsAdvConfig 29 } + +upsAdvConfigBasicSignalLowBatteryDuration OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The duration of runtime in seconds during an on-battery condition at which + the UPS will signal the basic low battery shutdown condition." + ::= { upsAdvConfig 30 } + +upsAdvConfigBypassPhaseLockRequired OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sets the condition for when bypass is an acceptable mode of operation as a + requirement." + ::= { upsAdvConfig 31 } + +upsAdvConfigOutputFreqSlewRate OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + slewRateQuarterHzPerSec (2), + slewRateHalfHzPerSec (3), + slewRate1HzPerSec (4), + slewRate2HzPerSec (5), + slewRate4HzPerSec (6), + slewRate6HzPerSec (7) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The rate at which the UPS will change its output frequency + in response to utility frequency changes." + ::= { upsAdvConfig 32 } + +upsAdvConfigChargerLevel OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + low (2), + high (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sets the rate at which the UPS charges its batteries." + ::= { upsAdvConfig 33 } + +upsAdvConfigBypassToleranceSetting OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + wide (2), + medium (3), + narrow (4), + custom (5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This setting allows selecting from standard bypass tolerance configurations to suit their situation." + ::= { upsAdvConfig 34 } + +upsAdvConfigMainsSetting OBJECT-TYPE + SYNTAX INTEGER { + singleInput (1), + dualInput (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Configure the type of mains supply system. + singleInput (1) indicates a single supply system. + dualInput (2) indicates a dual supply system. " + ::= { upsAdvConfig 35 } + +upsAdvConfigACWiringSetting OBJECT-TYPE + SYNTAX INTEGER { + threeWire (1), + fourWire (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Configure the AC wiring of the system. + threeWire (1) indicates 3-wire system configuration. + fourWire (2) indicates 4-wire system configuration. " + ::= { upsAdvConfig 36 } + +upsAdvConfigUpperOutputVoltTolerance OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Upper tolerance of the output RMS voltage before transferring to bypass. + Expressed as percent of nominal voltage." + ::= { upsAdvConfig 37 } + +upsAdvConfigLowerOutputVoltTolerance OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Lower tolerance of the output RMS voltage before transferring to bypass. + Expressed as percent of nominal voltage." + ::= { upsAdvConfig 38 } + +upsAdvConfigUpperBypassVoltTolerance OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Upper tolerance of the bypass voltage that allows transfer to bypass by user. + Expressed as percent of nominal voltage." + ::= { upsAdvConfig 39 } + +upsAdvConfigLowerBypassVoltTolerance OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Lower tolerance of the bypass voltage that allows transfer to bypass by user. + Expressed as percent of nominal voltage." + ::= { upsAdvConfig 40 } + +upsAdvConfigOutofSyncBypassTransferDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure the time (in milliseconds), indicating the gap in output voltage + if an asynchronous transfer to bypass needs to occur." + ::= { upsAdvConfig 41 } + + + + +upsAdvConfigWarningAlarmDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure the time delay for reporting warning alarms + (in seconds)." + ::= { upsAdvConfig 43 } + +upsAdvConfigInformationalAlarmDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure the time delay for reporting informational alarms + (in seconds)." + ::= { upsAdvConfig 44 } + +upsAdvConfigGreenMode OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/Disable UPS green mode feature." + ::= { upsAdvConfig 45 } + +upsAdvConfigLCDLocalLanguage OBJECT-TYPE + SYNTAX INTEGER { + english (1), + french (2), + italian (3), + german (4), + spanish (5), + portuguese (6), + japanese (7) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure the language setting of the UPS LCD display information." + ::= { upsAdvConfig 46 } + +upsAdvConfigLCDLockOut OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/Disable the control function of the UPS via the LCD Display." + ::= { upsAdvConfig 47 } + +upsAdvConfigChargerRate OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Change the maximum allowed UPS charge rate on select products where 100% represents + the manufacturer's recommended rate. A charge/discharge rate of C/10 for a 10 Ah + battery would be 1 where C is defined as the charge or discharge rate equal to the + capacity of a battery divided by 1 hour. To increase the charge rate by a factor of + 2 to C/5, this oid would be set to 200%. This number would not change when external + packs are added or removed. Charging at too high a rate can result in boiling and/or + venting of electrolyte and/or high gas pressure." + ::= { upsAdvConfig 48 } + +upsAdvConfigBatterySelection OBJECT-TYPE + SYNTAX INTEGER { + vrla (1), + ventedcell (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure the installed battery type on select products where VRLA is Valve Regulated + Lead Acid type battery and Vented Cell is a wet cell type (car) battery." + ::= { upsAdvConfig 49 } + + +-- the upsSyncCtrlGroupConfig group + +upsSCGMembershipGroupNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The SCG Membership Group number (MGN) is a 16-bit number allowing + up to 65534 separate groups that can be identified and distinguished + per IP subnet. Zero and 65535 are not used. The MGN is used in all + communication between members of the SCG and a Network Management Card + (NMC) will listen and only respond to commands sent to it using its + configured SCG ID." + ::= { upsSyncCtrlGroupConfig 1 } + +upsSCGActiveMembershipStatus OBJECT-TYPE + SYNTAX INTEGER { + enabledSCG (1), + disabledSCG (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Membership in the configured SCG can be enabled and + disabled. If an NMC is configured for an SCG, but + has its membership disabled, all synchronized control commands + received will be ignored." + ::= { upsSyncCtrlGroupConfig 2 } + +upsSCGPowerSynchronizationDelayTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The Power Synchronization Delay Time (PSD) setting is the maximum + number of seconds an SCG Initiator will wait for all SCG members to + recover utility power before completing the reboot sequence of a + reboot or sleep command. If all SCG members are ready to proceed, + no additional delay is introduced." + ::= { upsSyncCtrlGroupConfig 3 } + +upsSCGReturnBatteryCapacityOffset OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A reboot command uses the Initiator's Return battery Capacity (RBC) to control + when the SCG completes this operation. In a Normal Control Operation (NCC) the + UPS will only complete the reboot if RBC is reached. Due to normal battery + charge rate variations it may be desirable for the Followers to complete the + reboot if they are within some range of the Initiator's RBC when the Initiator + is prepared (charged to RBC) to complete the reboot. The Return Battery + Capacity Offset (RBCO) defines a percent battery capacity subtracted from an + RBC above which a Follower's battery must be charged for it to complete a + reboot. For example, if the Initiator's RBC is 50% and the Initiator's RBCO is + 5% then a Follower's battery capacity is within range if it is greater or equal + to 45% (50% - 5%) at the time when the Initiator tries to complete the reboot + command. The default RBCO is 10%. " + ::= { upsSyncCtrlGroupConfig 4 } + +upsSCGMultiCastIP OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The MultiCast IP address of the SCG Group." + ::= { upsSyncCtrlGroupConfig 5 } + + +-- the upsSyncCtrlGroupStatus group + +upsSCGNumOfGroupMembers OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of active, communicating members in the Sync Control Group (SCG). + This variable indicates the number of rows in the SCG Status Table." + ::= { upsSyncCtrlGroupStatus 1 } + +-- Sync Control Group Status Table + +upsSCGStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsSCGStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of SCG status table entries. The number of entries + is given by the value of upsSCGNumOfGroupMembers." + ::= { upsSyncCtrlGroupStatus 2 } + + upsSCGStatusEntry OBJECT-TYPE + SYNTAX UpsSCGStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular SCG Member." + INDEX { upsSCGStatusTableIndex } + ::= { upsSCGStatusTable 1 } + + UpsSCGStatusEntry ::= SEQUENCE { + upsSCGStatusTableIndex INTEGER, + upsSCGMemberIP IpAddress, + upsSCGACInputStatus INTEGER, + upsSCGACOutputStatus INTEGER + } + + upsSCGStatusTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of a status entry for an active, communicating SCG member." + ::= { upsSCGStatusEntry 1 } + + upsSCGMemberIP OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The IP address of an active, communicating SCG Member." + ::= { upsSCGStatusEntry 2 } + + upsSCGACInputStatus OBJECT-TYPE + SYNTAX INTEGER { + acInGood(1), + acInBad(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID indicates the AC Input Status of the SCG Member. + acInGood(1) indicates the AC Input is within tolerance. + acInBad(2) indicates the AC Input is not within tolerance." + ::= { upsSCGStatusEntry 3 } + + upsSCGACOutputStatus OBJECT-TYPE + SYNTAX INTEGER { + acOutOn(1), + acOutOff(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID indicates the AC Output Status of the SCG Member. + acOutOn(1) indicates the UPS output is providing power to the load. + acOutOff(2) indicates the UPS output is not providing power to the load. " + ::= { upsSCGStatusEntry 4 } + +-- the upsBasicState group + + +upsBasicStateOutputState OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ASCII string containing the 64 flags representing + the current state(s) of the UPS. If the Network Card + is unable to determine the state of the UPS, this + variable is set to 'UNKNOWN'. + + The flags are numbered 1 to 64, read from left to + right. The flags are defined as follows: + + Flag 1: Abnormal Condition Present + Flag 2: On Battery + Flag 3: Low Battery + Flag 4: On Line + + Flag 5: Replace Battery + Flag 6: Serial Communication Established + Flag 7: AVR Boost Active + Flag 8: AVR Trim Active + + Flag 9: Overload + Flag 10: Runtime Calibration + Flag 11: Batteries Discharged + Flag 12: Manual Bypass + + Flag 13: Software Bypass + Flag 14: In Bypass due to Internal Fault + Flag 15: In Bypass due to Supply Failure + Flag 16: In Bypass due to Fan Failure + + Flag 17: Sleeping on a Timer + Flag 18: Sleeping until Utility Power Returns + Flag 19: On + Flag 20: Rebooting + + Flag 21: Battery Communication Lost + Flag 22: Graceful Shutdown Initiated + Flag 23: Smart Boost or Smart Trim Fault + Flag 24: Bad Output Voltage + + Flag 25: Battery Charger Failure + Flag 26: High Battery Temperature + Flag 27: Warning Battery Temperature + Flag 28: Critical Battery Temperature + + Flag 29: Self Test In Progress + Flag 30: Low Battery / On Battery + Flag 31: Graceful Shutdown Issued by Upstream Device + Flag 32: Graceful Shutdown Issued by Downstream Device + + Flag 33: No Batteries Attached + Flag 34: Synchronized Command is in Progress + Flag 35: Synchronized Sleeping Command is in Progress + Flag 36: Synchronized Rebooting Command is in Progress + + Flag 37: Inverter DC Imbalance + Flag 38: Transfer Relay Failure + Flag 39: Shutdown or Unable to Transfer + Flag 40: Low Battery Shutdown + + Flag 41: Electronic Unit Fan Failure + Flag 42: Main Relay Failure + Flag 43: Bypass Relay Failure + Flag 44: Temporary Bypass + + Flag 45: High Internal Temperature + Flag 46: Battery Temperature Sensor Fault + Flag 47: Input Out of Range for Bypass + Flag 48: DC Bus Overvoltage + + Flag 49: PFC Failure + Flag 50: Critical Hardware Fault + Flag 51: Green Mode/ECO Mode + Flag 52: Hot Standby + + Flag 53: Emergency Power Off (EPO) Activated + Flag 54: Load Alarm Violation + Flag 55: Bypass Phase Fault + Flag 56: UPS Internal Communication Failure + + Flag 57: Efficiency Booster Mode + Flag 58: Off + Flag 59: Standby + Flag 60: + + Flag 61: + Flag 62: + Flag 63: + Flag 64: " + ::= { upsBasicState 1 } + + + +-- the upsAdvState group + +upsAdvStateAbnormalConditions OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ASCII string containing the 32 flags representing + the current active UPS faults. If the Network Card + is unable to determine the values of the flags, this + variable is set to 'UNKNOWN'. If this variable is not + supported by the connected UPS, this variable is set to + 'NOT SUPPORTED'. + + The flags are numbered from 1 to 32, and read from left to + right. The flags are defined as follows: + + Flag 1: Power Module Failure + Flag 2: Main Intelligence Module Failure + Flag 3: Redundant Intelligence Module Failure + Flag 4: Battery Failure + + Flag 5: Load(kVA) Alarm Threshold Violation + Flag 6: Redundancy Lost + Flag 7: Redundancy Below Alarm Threshold + Flag 8: Bypass not in Range; Either Frequency or Voltage + + Flag 9: Bypass Contactor Stuck in Bypass Condition + Flag 10: Bypass Contactor Stuck in On-Line Condition + Flag 11: In Bypass due to an Internal Fault + Flag 12: In Bypass due to an Overload + + Flag 13: In Maintenance Bypass + Flag 14: Input Circuit Braker Tripped Open + Flag 15: System Level Fan Failure + Flag 16: Redundant Intelligent Module in Control + + Flag 17: IIC Inter-Module Communication Failure + Flag 18: No Working Power Modules + Flag 19: Load Shutdown From Bypass; Input Frequency + Flag 20: Runtime Below Alarm Threshold + + Flag 21: Extended Run Frame Fault + Flag 22: Output Voltage out of Range + Flag 23: UPS Not Synchronized + Flag 24: No Batteries Installed + + Flag 25: Battery Voltage High + Flag 26: UPS Specific Fault Detected + Flag 27: Site Wiring Fault + Flag 28: Backfeed Protection Relay Opened + + Flag 29: + Flag 30: + Flag 31: + Flag 32: " + ::= { upsAdvState 1 } + +upsAdvStateSymmetra3PhaseSpecificFaults OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ASCII string containing the 64 flags representing + the current active UPS specific faults for the Symmetra + 3-Phase UPS models. If the Network Card is unable to + determine the values of the flags, this variable is set + to 'UNKNOWN'. If the connected UPS does not use this + variable, it is set to 'NOT SUPPORTED'. + + The flags are numbered from 1 to 64, and read from left + to right. The bits are defined as follows: + + Flag 1: External Switch Gear Failure + Flag 2: External Transformer Over Temperature + Flag 3: External DC Circuit Breaker Tripped + Flag 4: System Power Supply Failure + + Flag 5: Battery Monitor Card Failure + Flag 6: Battery Monitor Card Removed + Flag 7: XR Communication Card Failure + Flag 8: XR Communication Card Removed + + Flag 9: External Switch Gear Monitoring Card Failure + Flag 10: External Switch Gear Monitoring Card Removed + Flag 11: Internal DC Circuit Breaker Tripped + Flag 12: Static Bypass Switch Failure + + Flag 13: System EEPROM Removed + Flag 14: System EEPROM Failure + Flag 15: UPS in Forced Bypass + Flag 16: Static Bypass Switch Module Removed + + Flag 17: System Start-Up Configuration Fault + Flag 18: Battery Charger Shutdown Externally + Flag 19: + Flag 20: + + Flag 21: + Flag 22: + Flag 23: + Flag 24: + + Flag 25: + Flag 26: + Flag 27: + Flag 28: + + Flag 29: + Flag 30: + Flag 31: + Flag 32: + + Flag 33: + Flag 34: + Flag 35: + Flag 36: + + Flag 37: + Flag 38: + Flag 39: + Flag 40: + + Flag 41: + Flag 42: + Flag 43: + Flag 44: + + Flag 45: + Flag 46: + Flag 47: + Flag 48: + + Flag 49: + Flag 50: + Flag 51: + Flag 52: + + Flag 53: + Flag 54: + Flag 55: + Flag 56: + + Flag 57: + Flag 58: + Flag 59: + Flag 60: + + Flag 61: + Flag 62: + Flag 63: + Flag 64: " + ::= { upsAdvState 2 } + +upsAdvStateDP300ESpecificFaults OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ASCII string containing the 64 flags representing + the current active UPS specific faults for the Silcon + DP300E UPS models. If the Network Card is unable to + determine the values of the flags, this variable is set + to 'UNKNOWN'. If the connected UPS does not use this + variable, it is set to 'NOT SUPPORTED'. + + The flags are numbered from 1 to 64, and read from left + to right. The bits are defined as follows: + + Flag 1: Peak Current Limiter Active + Flag 2: Bypass Power Supply Fault + Flag 3: Delta Current Limiter Active + Flag 4: Fan Fault + + Flag 5: High DC warning + Flag 6: Inverter Voltage Error + Flag 7: Parallel Synchronization Error + Flag 8: Second Power Supply Fault + + Flag 9: Internal Power Supply Fault + Flag 10: + Flag 11: + Flag 12: + + Flag 13: + Flag 14: Bypass Static Switch High Temperature + Flag 15: High Battery Temperature + Flag 16: Battery Weak + + Flag 17: + Flag 18: System Locked in Operation Mode + Flag 19: RAM1 Memory Write Error + Flag 20: Memory Write Error + + Flag 21: Communication to VQ Bypass Lost + Flag 22: Communication to VQ Output Lost + Flag 23: Communication to DMU Lost + Flag 24: Communication to Controller Lost + + Flag 25: Communication to Parallel IF Lost + Flag 26: External Shutdown Accepted + Flag 27: DC Capacitor Charge Error + Flag 28: Communication to VQ Mains Lost + + Flag 29: Bypass Synchronization Error + Flag 30: Charge Error + Flag 31: SII Aux Input Activiated + Flag 32: + + Flag 33: Blown Inverter Fuse + Flag 34: Blown Rectifier Fuse + Flag 35: Auxilliary 1 Fault + Flag 36: + + Flag 37: + Flag 38: + Flag 39: + Flag 40: + + Flag 41: + Flag 42: + Flag 43: + Flag 44: + + Flag 45: + Flag 46: High Temperature Charger Magnetic + Flag 47: + Flag 48: Battery Monitor Warning + + Flag 49: Battery Monitor Alarm + Flag 50: + Flag 51: + Flag 52: + + Flag 53: TSM 1/2/3 Temperature Shutdown + Flag 54: Charger 0/30 Temperature Warning + Flag 55: Charger 0/30 Temperature Shutdown + Flag 56: High Output Voltage + + Flag 57: SSW Temperature Over 90 + Flag 58: + Flag 59: Low Current Failure In AC Capacitors + Flag 60: + + Flag 61: Advanced Battery Management Not Installed + Flag 62: + Flag 63: + Flag 64: " + ::= { upsAdvState 3 } + +upsAdvStateSymmetraSpecificFaults OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ASCII string containing the 64 flags representing + the current active UPS specific faults for the Symmetra + UPS models. If the Network Card is unable to determine + the values of the flags, this variable is set to 'UNKNOWN'. + If the connected UPS does not use this variable, it is + set to 'NOT SUPPORTED'. + + The flags are numbered from 1 to 64, and read from left + to right. The bits are defined as follows: + + Flag 1: System Fault + Flag 2: Bypass Relay Fault + Flag 3: Power Module Turn Off Failure + Flag 4: Frame Identification Fault + + Flag 5: + Flag 6: + Flag 7: + Flag 8: + + Flag 9: + Flag 10: + Flag 11: + Flag 12: + + Flag 13: + Flag 14: + Flag 15: + Flag 16: + + Flag 17: + Flag 18: + Flag 19: + Flag 20: + + Flag 21: + Flag 22: + Flag 23: + Flag 24: + + Flag 25: + Flag 26: + Flag 27: + Flag 28: + + Flag 29: + Flag 30: + Flag 31: + Flag 32: + + Flag 33: + Flag 34: + Flag 35: + Flag 36: + + Flag 37: + Flag 38: + Flag 39: + Flag 40: + + Flag 41: + Flag 42: + Flag 43: + Flag 44: + + Flag 45: + Flag 46: + Flag 47: + Flag 48: + + Flag 49: + Flag 50: + Flag 51: + Flag 52: + + Flag 53: + Flag 54: + Flag 55: + Flag 56: + + Flag 57: + Flag 58: + Flag 59: + Flag 60: + + Flag 61: + Flag 62: + Flag 63: + Flag 64: " + ::= { upsAdvState 4 } + +upsAdvStateSmartUPSSpecificFaults OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ASCII string containing the 64 flags representing + the current active UPS specific faults for the Smart-UPS + UPS models. If the Network Card is unable to determine + the values of the flags, this variable is set to + 'UNKNOWN'. If the connected UPS does not use this + variable, it is set to 'NOT SUPPORTED'. + + The flags are numbered from 1 to 64, and read from left + to right. The bits are defined as follows: + + Flag 1: EPO Switch Activated + Flag 2: Static Bypass Switch Fault + Flag 3: System Configuration Fault + Flag 4: Power Supply Unit Fault + + Flag 5: Weak Battery + Flag 6: High Battery Temperature + Flag 7: Internal Mechanical Bypass + Flag 8: Loss Of Parallel Redundancy + + Flag 9: Parallel Bus Communication Fault on Cable 1 + Flag 10: Parallel Bus Communication Fault on Cable 2 + Flag 11: Auxiliary Bus Communication Fault + Flag 12: Parallel Bus Termination Fault on Cable 1 + + Flag 13: Parallel Bus Termination Fault on Cable 2 + Flag 14: Auxiliary Bus Termination Fault + Flag 15: No Master Present In The Parallel System + Flag 16: Overload on a Parallel Unit + + Flag 17: Parallel Configuration Fault + Flag 18: + Flag 19: + Flag 20: + + Flag 21: + Flag 22: + Flag 23: + Flag 24: + + Flag 25: + Flag 26: + Flag 27: + Flag 28: + + Flag 29: + Flag 30: + Flag 31: + Flag 32: + + Flag 33: + Flag 34: + Flag 35: + Flag 36: + + Flag 37: + Flag 38: + Flag 39: + Flag 40: + + Flag 41: + Flag 42: + Flag 43: + Flag 44: + + Flag 45: + Flag 46: + Flag 47: + Flag 48: + + Flag 49: + Flag 50: + Flag 51: + Flag 52: + + Flag 53: + Flag 54: + Flag 55: + Flag 56: + + Flag 57: + Flag 58: + Flag 59: + Flag 60: + + Flag 61: + Flag 62: + Flag 63: + Flag 64: " + ::= { upsAdvState 5 } + + +upsAdvStateSystemMessages OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ASCII string containing the 3 digit Decimal code + representing the current active message from the + System Message Register. Each code should remain active + for a minimum of 15 seconds. However, in the worst case + scenario, a code could be cleared after only 5 seconds. + It is recommended that this object be polled at least + once every 4 seconds in order to get the most accurate + representation of the current UPS System Message. If the + Network Card is unable to determine the value of the + System Message Register, this variable is set to + 'UNKNOWN'." + ::= { upsAdvState 6 } + + +upsAdvStateTotaltimeonbattery OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Total time the UPS has been in battery operation." + ::= { upsAdvState 7 } + +upsAdvStateTotaltimeonbypass OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Total time the UPS has been in bypass operation." + ::= { upsAdvState 8 } + +upsAdvStateTotaltimeonNormal OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Total time the UPS has been in normal operation." + ::= { upsAdvState 9 } + +upsAdvStateNumberoftimesonbattery OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of times the UPS was on battery. + Since the last reset of statistical data." + ::= { upsAdvState 10 } + +upsAdvStateNumberoftimesbypass OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of times the UPS was in bypass. + Since the last reset of statistical data." + ::= { upsAdvState 11 } + +upsAdvStateNumberoftimesNormal OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of times the UPS was in normal operation. + Since the last reset of statistical data." + ::= { upsAdvState 12 } + +upsAdvStateEcomode OBJECT-TYPE + SYNTAX INTEGER { + upsOnEcoMode(1), + upsNotOnEcoMode(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Eco mode status. + 1: UPS is on Eco-mode + 2: UPS is not on Eco-mode." + ::= { upsAdvState 13 } + +-- the upsBasicControl group + +upsBasicControlConserveBattery OBJECT-TYPE + SYNTAX INTEGER { + noTurnOffUps(1), + turnOffUpsToConserveBattery(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this variable to turnUpsOffToConserveBattery(2) + causes a UPS on battery to be put into 'sleep' mode. The + UPS will turn back on when utility power is restored. + Attempting to turn off a UPS that is not on battery will + result in a badValue error. + + Setting this value to noTurnOffUps(1) has no + effect. + + The value noTurnOffUps(1) will always be returned + when the variable is read." +::= { upsBasicControl 1 } + + + +-- the upsAdvControl group + +upsAdvControlUpsOff OBJECT-TYPE + SYNTAX INTEGER { + noTurnUpsOff(1), + turnUpsOff(2), + turnUpsOffGracefully(3), + turnUpsSyncGroupOff(4), + turnUpsSyncGroupOffAfterDelay(5), + turnUpsSyncGroupOffGracefully(6) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this variable to turnUpsOff(2) causes + the UPS to shut off. When in this state, the UPS + will not provide output power regardless of the input + line state. + + Setting this variable to turnUpsOffGracefully(3) causes + the UPS to shut off after a delay period. This allows the + host to shut down in a graceful manner. When in this state, + the UPS will not provide output power regardless of the + input line state. + + If this UPS is an active member of a Synchronized + Control Group (SCG) the turnUpsSyncGroupOff(4) command + will perform a Synchronized Turn Off of all active Group + members regardless of their current AC output status. + + If this UPS is an active member of a Synchronized + Control Group (SCG) the turnUpsSyncGroupOffAfterDelay(5) + command will perform a Synchronized Turn Off After Delay + of all active Group members regardless of their current + AC output status. This unit's Shutdown Delay will be used + to execute the Turn Off After Delay command. + + If this UPS is an active member of an SCG, the + turnUpsSyncGroupOffGracefully(6) command will perform a + Synchronized Turn Off Gracefully of all active Group + members regardless of their current AC output status. + This unit's Maximum Shutdown Time and Shutdown Delay will + be used to execute the Turn Off Gracefully command. + + Setting this value to noTurnUpsOff(1) has no + effect. + + The value noTurnUpsOff(1) will always be returned + when the variable is read." + ::= { upsAdvControl 1 } + +upsAdvControlRebootShutdownUps OBJECT-TYPE + SYNTAX INTEGER { + noRebootShutdownUps(1), + rebootShutdownUps(2), + rebootShutdownUpsGracefully(3), + rebootShutdownSyncGroupUps(4), + rebootShutdownSyncGroupUpsGracefully(5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this variable to rebootShutdownUps(2) causes the UPS + to shut off and turn back on (as long as good AC input power + is available, otherwise the UPS will remain off until good AC + input power is available). + + Setting this variable to rebootShutdownUpsGracefully(3) causes + the UPS to shut off after a delay period and then turn back + on. This allows the host to shut down in a graceful manner. + + If this UPS is an active member of a Synchronized Control + Group (SCG) the rebootShutdownSyncGroupUps(4) command will + perform a Synchronized Reboot of all active Group members + regardless of their current AC output status. If applicable, + this unit's Power Synchronization Delay, Shutdown Delay, + Return Delay, Return Battery Capacity, and Return Battery + Capacity Offset will be used to execute the Reboot command. + + If this UPS is an active member of a SCG the + rebootShutdownSyncGroupUpsGracefully(5) command will perform + a Synchronized Reboot of all active Group members regardless + of their current AC output status. If applicable, this unit's + Power Synchronization Delay, Maximum Shutdown Time, Shutdown + Delay, Return Delay, Return Battery Capacity, and Return + Battery Capacity Offset will be used to execute the Reboot + command. + + Setting this value to noRebootShutdownUps(1) has no effect. + + The value noRebootShutdownUps(1) will always be returned when + the variable is read." + ::= { upsAdvControl 2 } + +upsAdvControlUpsSleep OBJECT-TYPE + SYNTAX INTEGER { + noPutUpsToSleep(1), + putUpsToSleep(2), + putUpsToSleepGracefully(3), + putUpsSyncGroupToSleep(4), + putUpsSyncGroupToSleepGracefully(5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this variable to putUpsToSleep(2) causes + the UPS to go to sleep for the time specified by + upsAdvConfigUpsSleepTime. + + Setting this variable to putUpsToSleepGracefully(3) + causes the UPS to go to sleep for the time specified + by upsAdvConfigUpsSleepTime after a delay period. + This allows the host to shut down in a graceful manner. + + If this UPS is an active member of a Synchronized Control + Group (SCG), the putUpsSyncGroupToSleep(4) command will perform + a Synchronized Sleep of all active Group members regardless + of their current AC output status. This unit's Power + Synchronization Delay, Shutdown Delay, Sleep Time, + and Return Delay will be used to execute the sleep command. + + If this UPS is an active member of a SCG the + putUpsSyncGroupToSleepGracefully(5) command will perform a + Synchronized Sleep Gracefully of all active Group members + regardless of their current AC output status. This unit's + Power Synchronization Delay, Maximum Shutdown Time, Shutdown + Delay, Sleep Time, and Return Delay to execute the sleep + command. + + When in sleep mode, the UPS will not provide output + power regardless of the input line state. Once the + specified time has elapsed, output power will be + restored. + + Setting this value to noPutUpsToSleep(1) has no + effect. + + The value noPutUpsToSleep(1) will always be returned + when the variable is read." + ::= { upsAdvControl 3 } + + +upsAdvControlSimulatePowerFail OBJECT-TYPE + SYNTAX INTEGER { + noSimulatePowerFailure(1), + simulatePowerFailure(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this variable to simulatePowerFailure(2) causes + the UPS switch to battery power. + + Setting this value to noSimulatePowerFailure(1) has no + effect. + + The value noSimulatePowerFailure(1) will always be returned + when the variable is read." + ::= { upsAdvControl 4 } + + +upsAdvControlFlashAndBeep OBJECT-TYPE + SYNTAX INTEGER { + noFlashAndBeep(1), + flashAndBeep(2), + flashAndBeepSyncGroup(3), + flashAndBeepCont(4), + flashAndBeepCancel(5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this variable to flashAndBeep(2) causes the + UPS to beep and simultaneously turn on the UPS front + panel lights (Smart-UPS only). + + If this UPS is an active member of a Synchronized Control + Group (SCG), the flashAndBeepSyncGroup(3) command will + Flash and Beep all active Group members regardless of + current AC output status. + + Setting this value to noFlashAndBeep(1) has no + effect. + + Setting this value to flashAndBeepCont (4) commandcauses + the UPS to beep and light the front panel lights until + the flashAndBeepCancel (5) command is received. + + The value noFlashAndBeep(1) will always be returned + when the variable is read." + ::= { upsAdvControl 5 } + + +upsAdvControlTurnOnUPS OBJECT-TYPE + SYNTAX INTEGER { + noTurnOnUPS(1), + turnOnUPS(2), + turnOnUPSSyncGroup(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this variable to turnOnUPS(2) causes the + UPS to be turned on immediately. + + If this UPS is an active member of a Synchronized Control + Group (SCG), the turnOnUPSSyncGroup(3) command will perform + a Synchronized Turn On of all active Group members + regardless of their current AC output status. + + Setting this value to noTurnOnUPS(1) has no + effect. + + The value noTurnOnUPS(1) will always be returned + when the variable is read." + ::= { upsAdvControl 6 } + +upsAdvControlBypassSwitch OBJECT-TYPE + SYNTAX INTEGER { + noBypassSwitch (1), + switchToBypass (2), + switchOutOfBypass(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This switch puts the UPS in or out of bypass mode." + ::= { upsAdvControl 7 } + +upsAdvControlRebootUpsWithOrWithoutAC OBJECT-TYPE + SYNTAX INTEGER { + noRebootUpsWithOrWithoutAC (1), + rebootUpsImmediatelyWithOrWithoutAC (2), + rebootUpsDelayedWithOrWithoutAC (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this variable to rebootUpsImmediatelyWithOrWithoutAC (2) + causes the UPS to turn off immediately, wait for a minimum time + (typically 8 seconds), and then turn back on regardless of the + AC input power on the UPS. Any supported switched outlet + groups will be turned off immediately but will turn on based + on their individual settings (to allow on sequencing). + + Setting this variable to rebootUpsDelayedWithOrWithoutAC (3) + causes the UPS to turn off after a delay period, wait for a + minimum time (typically 8 seconds), and then turn back on + regardless of the AC input power on the UPS. Any supported + switched outlet groups will be turned off and on based on their + individual settings (to allow off and/or on sequencing). + + Setting this value to noRebootUpsWithOrWithoutAC (1) has no + effect. + + The value noRebootUpsWithOrWithoutAC (1) will always be + returned when the variable is read." + ::= { upsAdvControl 8 } + +upsAdvControlFirmwareUpdate OBJECT-TYPE + SYNTAX INTEGER { + noFirmwareUpdate (1), + firmwareUpdate (2), + updateInProcess (3), + updateSuccessful (4), + updateFailed (5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this variable to firmwareUpdate(2) causes the + UPS to begin a firmware update if possible. + + Setting this value to noFirmwareUpdate(1) will clear the + previous results, if any, or otherwise has no effect. + + Reading this variable will return noFirmwareUpdate(1) when + the UPS firmware has not been updated (or previous results + have been cleared), updateInProcess(3) when the UPS firmware + is being updated, updateSuccessful(4) when the UPS firmware + has been successfully updated, or updateFailed(5) if the UPS + firmware update failed." + ::= { upsAdvControl 9 } + + +-- the upsTest group + +-- the upsBasicTest group + +-- the upsAdvTest group + +upsAdvTestDiagnosticSchedule OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + biweekly(2), + weekly(3), + atTurnOn(4), + never(5), + fourWeeks(6), + twelveWeeks(7), + biweeklySinceLastTest(8), + weeklySinceLastTest(9), + eightWeeks(10), + twentysixWeeks(11), + fiftytwoWeeks(12) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The UPS system's automatic battery test schedule." + ::= { upsAdvTest 1 } + + +upsAdvTestDiagnostics OBJECT-TYPE + SYNTAX INTEGER { + noTestDiagnostics(1), + testDiagnostics(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this variable to testDiagnostics(2) causes + the UPS to perform a diagnostic self test. + + Setting this value to noTestDiagnostics(1) has no + effect. + + The value noTestDiagnostics(1) will always be returned + when the variable is read." + ::= { upsAdvTest 2 } + +upsAdvTestDiagnosticsResults OBJECT-TYPE + SYNTAX INTEGER { + ok(1), + failed(2), + invalidTest(3), + testInProgress(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The results of the last UPS diagnostics test performed." + ::= { upsAdvTest 3 } + +upsAdvTestLastDiagnosticsDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date the last UPS diagnostics test was performed in + mm/dd/yy format." + ::= { upsAdvTest 4 } + +upsAdvTestRuntimeCalibration OBJECT-TYPE + SYNTAX INTEGER { + noPerformCalibration(1), + performCalibration(2), + cancelCurrentCalibration(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this variable to performCalibration(2) causes + the UPS to discharge to calibrate the UPS. + The test will only start if the battery capacity is 100%. + The test runs until capacity is less than 25%. + + Setting this variable to cancelCurrentCalibration(3) + after setting performCalibration(2) will cancel the + current discharge. + + Setting this variable to noPerformCalibration(1) + will have no effect. + + The value noPerformCalibration(1) will always be returned + when the variable is read. + + The result of the calibration will be saved in + upsAdvTestCalibrationResult." + ::= { upsAdvTest 5 } + +upsAdvTestCalibrationResults OBJECT-TYPE + SYNTAX INTEGER { + ok(1), + invalidCalibration(2), + calibrationInProgress(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The results of the last runtime calibration. + + Value ok(1) means a successful runtime calibration. + + Value invalidCalibration(2) indicates last calibration did + not take place since the battery capacity was below + 100%. + + Value calibrationInProgress(3) means a calibration + is occurring now. " + ::= { upsAdvTest 6 } + +upsAdvTestCalibrationDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date the last UPS runtime calibration was + performed in mm/dd/yy format." + ::= { upsAdvTest 7 } + +upsAdvTestDiagnosticTime OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The time of the day to perform automatic battery test. + Expressed in 24 hour notation - hh:mm." + ::= { upsAdvTest 8 } + +upsAdvTestDiagnosticDay OBJECT-TYPE + SYNTAX INTEGER { + monday (1), + tuesday (2), + wednesday (3), + thursday (4), + friday (5), + saturday (6), + sunday (7) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The day of the week to perform automatic battery test." + ::= { upsAdvTest 9 } + +-- the upsComm group + +upsCommStatus OBJECT-TYPE + SYNTAX INTEGER { + ok(1), + noComm(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of agent's communication with UPS. " + ::= { upsComm 1 } + + +-- the measureUps group +-- the Environ group + +mUpsEnvironAmbientTemperature OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The ambient temperature in Celsius for Probe 1." + ::= { mUpsEnviron 1 } + +mUpsEnvironRelativeHumidity OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The relative humidity as a percentage for Probe 1." + ::= { mUpsEnviron 2 } + + +mUpsEnvironAmbientTemperature2 OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The ambient temperature in Celsius for Probe 2." + ::= { mUpsEnviron 3 } + +mUpsEnvironRelativeHumidity2 OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The relative humidity as a percentage for Probe 2." + ::= { mUpsEnviron 4 } + +-- the mUpsContact group + +mUpsContactNumContacts OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of contacts supported by the Measure-UPS." + ::= { mUpsContact 1 } + +mUpsContactTable OBJECT-TYPE + SYNTAX SEQUENCE OF MUpsContactEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of contacts supported by the Measure-UPS." + ::= { mUpsContact 2 } + +mUpsContactEntry OBJECT-TYPE + SYNTAX MUpsContactEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A contact entry containing information for a given contact." + INDEX { contactNumber } + ::= { mUpsContactTable 1 } + +MUpsContactEntry ::= + SEQUENCE { + contactNumber + INTEGER, + normalState + INTEGER, + description + DisplayString, + monitoringStatus + INTEGER, + currentStatus + INTEGER + } + +contactNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index identifying the contact on the Measure-UPS." + ::= { mUpsContactEntry 1 } + +normalState OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + open(2), + closed(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal operating position of the contact. If the normal + operating position cannot be set then it is controlled via the + dip switch on the Measure-UPS and is therefore read-only." + ::= { mUpsContactEntry 2 } + +description OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The description of the purpose/use of the contact." + ::= { mUpsContactEntry 3 } + +monitoringStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + enabled(2), + disabled(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A flag indicating whether this contact is + monitored, or not." + ::= { mUpsContactEntry 4 } + +currentStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + noFault(2), + fault(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This value indicates the current state of the contact. + If the contact is not in its normal state. This value + is set to fault(2)." + ::= { mUpsContactEntry 5 } + +-- Three Phase Group + +-- +-- Reset Max/Min Values Group +-- + + upsPhaseResetMaxMinValues OBJECT-TYPE + SYNTAX INTEGER { + none (1), + reset (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset the maximum and minimum UPS values: + upsPhaseInputMaxVoltage, upsPhaseInputMinVoltage, + upsPhaseInputMaxCurrent, upsPhaseInputMinCurrent, + upsPhaseInputMaxPower, upsPhaseInputMinPower, + upsPhaseOutputMaxCurrent, upsPhaseOutputMinCurrent, + upsPhaseOutputMaxLoad, upsPhaseOutputMinLoad, + upsPhaseOutputMaxPercentLoad, upsPhaseOutputMinPercentLoad, + upsPhaseOutputMaxPower, upsPhaseOutputMinPower, + upsPhaseOutputMaxPercentPower, upsPhaseOutputMinPercentPower." + ::= { upsPhaseResetValues 1 } + +-- +-- Input Group +-- + +-- Number of Inputs + + upsPhaseNumInputs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of input feeds to this device. + This variable indicates the number of rows in the + input table." + ::= { upsPhaseInput 1 } + +-- Input Table + + upsPhaseInputTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsPhaseInputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of input table entries. The number of entries + is given by the value of upsPhaseNumInputs." + ::= { upsPhaseInput 2 } + + upsPhaseInputEntry OBJECT-TYPE + SYNTAX UpsPhaseInputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular input." + INDEX { upsPhaseInputTableIndex } + ::= { upsPhaseInputTable 1 } + + UpsPhaseInputEntry ::= SEQUENCE { + upsPhaseInputTableIndex INTEGER, + upsPhaseNumInputPhases INTEGER, + upsPhaseInputVoltageOrientation INTEGER, + upsPhaseInputFrequency INTEGER, + upsPhaseInputType INTEGER, + upsPhaseInputName DisplayString + } + + upsPhaseInputTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input identifier." + ::= { upsPhaseInputEntry 1 } + + upsPhaseNumInputPhases OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of input phases utilized in this + device. The sum of all the upsPhaseNumInputPhases + variable indicates the number of rows in the + input phase table." + ::= { upsPhaseInputEntry 2 } + + upsPhaseInputVoltageOrientation OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + singlePhase(2), + splitPhase(3), + threePhasePhaseToNeutral(4), + threePhasePhaseToPhase(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input voltage orientation: + 1: unknown for this UPS + 2: singlePhase - phase 1 voltage is between Phase 1 + and Neutral. + 3: splitPhase - phase 1 voltage is between Phase 1 and + Neutral; phase 2 voltage is between Phase 2 and Neutral; + phase 3 voltage is between Phase 1 and Phase 2. + 4: threePhasePhaseToNeutral - phase 1 voltage is between + Phase 1 and Neutral; phase 2 voltage is between Phase 2 + and Neutral; phase 3 voltage is between Phase 3 and + Neutral. + 5: threePhasePhaseToPhase - phase 1 voltage is between + Phase 1 and Phase 2; phase 2 voltage is between Phase 2 + and Phase 3; phase 3 voltage is between Phase 3 and + Phase 1." + ::= { upsPhaseInputEntry 3 } + + upsPhaseInputFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input frequency in 0.1 Hertz, or -1 if it's unsupported + by this UPS." + ::= { upsPhaseInputEntry 4 } + + upsPhaseInputType OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + main(2), + bypass(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input type." + ::= { upsPhaseInputEntry 5 } + + upsPhaseInputName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A name given to a particular input." + ::= { upsPhaseInputEntry 6 } + +-- Input Phase Table + + upsPhaseInputPhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsPhaseInputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of input table entries. The number of entries + is given by the sum of the upsPhaseNumInputPhases." + ::= { upsPhaseInput 3 } + + upsPhaseInputPhaseEntry OBJECT-TYPE + SYNTAX UpsPhaseInputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular input phase." + INDEX { upsPhaseInputPhaseTableIndex, upsPhaseInputPhaseIndex } + ::= { upsPhaseInputPhaseTable 1 } + + UpsPhaseInputPhaseEntry ::= SEQUENCE { + upsPhaseInputPhaseTableIndex INTEGER, + upsPhaseInputPhaseIndex INTEGER, + upsPhaseInputVoltage INTEGER, + upsPhaseInputMaxVoltage INTEGER, + upsPhaseInputMinVoltage INTEGER, + upsPhaseInputCurrent INTEGER, + upsPhaseInputMaxCurrent INTEGER, + upsPhaseInputMinCurrent INTEGER, + upsPhaseInputPower INTEGER, + upsPhaseInputMaxPower INTEGER, + upsPhaseInputMinPower INTEGER, + upsPhaseInputApparentPower INTEGER, + upsPhaseInputPowerFactor INTEGER + } + + upsPhaseInputPhaseTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input identifier." + ::= { upsPhaseInputPhaseEntry 1 } + + upsPhaseInputPhaseIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input phase identifier." + ::= { upsPhaseInputPhaseEntry 2 } + + upsPhaseInputVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input voltage in VAC, or -1 if it's unsupported + by this UPS." + ::= { upsPhaseInputPhaseEntry 3 } + + upsPhaseInputMaxVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum input voltage in VAC measured + since the last reset (upsPhaseResetMaxMinValues), or + -1 if it's unsupported by this UPS. + Sampled every 30 seconds." + ::= { upsPhaseInputPhaseEntry 4 } + + upsPhaseInputMinVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum input voltage in VAC measured + since the last reset (upsPhaseResetMaxMinValues), or + -1 if it's unsupported by this UPS. + Sampled every 30 seconds." + ::= { upsPhaseInputPhaseEntry 5 } + + upsPhaseInputCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input current in 0.1 amperes, or -1 if it's + unsupported by this UPS." + ::= { upsPhaseInputPhaseEntry 6 } + + upsPhaseInputMaxCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum input current in 0.1 amperes measured + since the last reset (upsPhaseResetMaxMinValues), or + -1 if it's unsupported by this UPS. + Sampled every 30 seconds." + ::= { upsPhaseInputPhaseEntry 7 } + + upsPhaseInputMinCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum input current in 0.1 amperes measured + since the last reset (upsPhaseResetMaxMinValues), or + -1 if it's unsupported by this UPS. + Sampled every 30 seconds." + ::= { upsPhaseInputPhaseEntry 8 } + + upsPhaseInputPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input power in Watts, or -1 if it's unsupported + by this UPS." + ::= { upsPhaseInputPhaseEntry 9 } + + upsPhaseInputMaxPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum input power in Watts measured + since the last reset (upsPhaseResetMaxMinValues), or + -1 if it's unsupported by this UPS. + Sampled every 30 seconds." + ::= { upsPhaseInputPhaseEntry 10 } + + upsPhaseInputMinPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum input power in Watts measured + since the last reset (upsPhaseResetMaxMinValues), or + -1 if it's unsupported by this UPS. + Sampled every 30 seconds." + ::= { upsPhaseInputPhaseEntry 11 } + + + upsPhaseInputApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input apparent power of the UPS in kVA." + ::= { upsPhaseInputPhaseEntry 12 } + + + upsPhaseInputPowerFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input power factor measured in hundredth." + ::= { upsPhaseInputPhaseEntry 13 } + + + + -- + -- The Output group. + -- + + -- Number of Outputs + + upsPhaseNumOutputs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of output feeds to this device. + This variable indicates the number of rows in the + output table." + ::= { upsPhaseOutput 1 } + + -- Output Table + + upsPhaseOutputTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsPhaseOutputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of output table entries. The number of entries + is given by the value of upsOutputNumPhases." + ::= { upsPhaseOutput 2 } + + upsPhaseOutputEntry OBJECT-TYPE + SYNTAX UpsPhaseOutputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular output." + INDEX { upsPhaseOutputTableIndex } + ::= { upsPhaseOutputTable 1 } + + UpsPhaseOutputEntry ::= SEQUENCE { + upsPhaseOutputTableIndex INTEGER, + upsPhaseNumOutputPhases INTEGER, + upsPhaseOutputVoltageOrientation INTEGER, + upsPhaseOutputFrequency INTEGER + } + + upsPhaseOutputTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output identifier." + ::= { upsPhaseOutputEntry 1 } + + upsPhaseNumOutputPhases OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of output phases utilized in this + device. The sum of all the upsPhaseNumOutputPhases + variable indicates the number of rows in the + output phase table." + ::= { upsPhaseOutputEntry 2 } + + upsPhaseOutputVoltageOrientation OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + singlePhase(2), + splitPhase(3), + threePhasePhaseToNeutral(4), + threePhasePhaseToPhase(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output voltage orientation: + 1: unknown for this UPS + 2: singlePhase - phase 1 voltage is between Phase 1 + and Neutral. + 3: splitPhase - phase 1 voltage is between Phase 1 and + Neutral; phase 2 voltage is between Phase 2 and Neutral; + phase 3 voltage is between Phase 1 and Phase 2. + 4: threePhasePhaseToNeutral - phase 1 voltage is between + Phase 1 and Neutral; phase 2 voltage is between Phase 2 + and Neutral; phase 3 voltage is between Phase 3 and + Neutral. + 5: threePhasePhaseToPhase - phase 1 voltage is between + Phase 1 and Phase 2; phase 2 voltage is between Phase 2 + and Phase 3; phase 3 voltage is between Phase 3 and + Phase 1." + ::= { upsPhaseOutputEntry 3 } + + upsPhaseOutputFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output frequency in 0.1 Hertz, or -1 if it's + unsupported by this UPS." + ::= { upsPhaseOutputEntry 4 } + + -- Output Phase Table + + upsPhaseOutputPhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsPhaseOutputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of output table entries. The number of + entries is given by the sum of the upsPhaseNumOutputPhases." + ::= { upsPhaseOutput 3 } + + upsPhaseOutputPhaseEntry OBJECT-TYPE + SYNTAX UpsPhaseOutputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular output phase." + INDEX { upsPhaseOutputPhaseTableIndex, upsPhaseOutputPhaseIndex } + ::= { upsPhaseOutputPhaseTable 1 } + + UpsPhaseOutputPhaseEntry ::= SEQUENCE { + upsPhaseOutputPhaseTableIndex INTEGER, + upsPhaseOutputPhaseIndex INTEGER, + upsPhaseOutputVoltage INTEGER, + upsPhaseOutputCurrent INTEGER, + upsPhaseOutputMaxCurrent INTEGER, + upsPhaseOutputMinCurrent INTEGER, + upsPhaseOutputLoad INTEGER, + upsPhaseOutputMaxLoad INTEGER, + upsPhaseOutputMinLoad INTEGER, + upsPhaseOutputPercentLoad INTEGER, + upsPhaseOutputMaxPercentLoad INTEGER, + upsPhaseOutputMinPercentLoad INTEGER, + upsPhaseOutputPower INTEGER, + upsPhaseOutputMaxPower INTEGER, + upsPhaseOutputMinPower INTEGER, + upsPhaseOutputPercentPower INTEGER, + upsPhaseOutputMaxPercentPower INTEGER, + upsPhaseOutputMinPercentPower INTEGER, + upsPhaseOutputPowerFactor INTEGER + } + + upsPhaseOutputPhaseTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output identifier." + ::= { upsPhaseOutputPhaseEntry 1 } + + upsPhaseOutputPhaseIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output phase identifier." + ::= { upsPhaseOutputPhaseEntry 2 } + + upsPhaseOutputVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output voltage in VAC, or -1 if it's unsupported + by this UPS." + ::= { upsPhaseOutputPhaseEntry 3 } + + upsPhaseOutputCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output current in 0.1 amperes drawn + by the load on the UPS, or -1 if it's unsupported + by this UPS." + ::= { upsPhaseOutputPhaseEntry 4 } + + upsPhaseOutputMaxCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum output current in 0.1 amperes measured + since the last reset (upsPhaseResetMaxMinValues), or + -1 if it's unsupported by this UPS. + Sampled every 30 seconds." + ::= { upsPhaseOutputPhaseEntry 5 } + + upsPhaseOutputMinCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum output current in 0.1 amperes measured + since the last reset (upsPhaseResetMaxMinValues), or + -1 if it's unsupported by this UPS. + Sampled every 30 seconds." + ::= { upsPhaseOutputPhaseEntry 6 } + + upsPhaseOutputLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output load in VA, or -1 if it's unsupported + by this UPS." + ::= { upsPhaseOutputPhaseEntry 7 } + + upsPhaseOutputMaxLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum output load in VA measured + since the last reset (upsPhaseResetMaxMinValues), or + -1 if it's unsupported by this UPS. + Sampled every 30 seconds." + ::= { upsPhaseOutputPhaseEntry 8 } + + upsPhaseOutputMinLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum output load in VA measured + since the last reset (upsPhaseResetMaxMinValues), or + -1 if it's unsupported by this UPS. + Sampled every 30 seconds." + ::= { upsPhaseOutputPhaseEntry 9 } + + upsPhaseOutputPercentLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The percentage of the UPS load capacity in VA at + redundancy @ (n + x) presently being used on this + output phase, or -1 if it's unsupported by this UPS." + ::= { upsPhaseOutputPhaseEntry 10 } + + upsPhaseOutputMaxPercentLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum percentage of the UPS load capacity in + VA measured at redundancy @ (n + x) presently + being used on this output phase since the last reset + (upsPhaseResetMaxMinValues), or -1 if it's unsupported + by this UPS. Sampled every 30 seconds." + ::= { upsPhaseOutputPhaseEntry 11 } + + upsPhaseOutputMinPercentLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum percentage of the UPS load capacity in + VA measured at redundancy @ (n + x) presently + being used on this output phase since the last reset + (upsPhaseResetMaxMinValues), or -1 if it's unsupported + by this UPS. Sampled every 30 seconds." + ::= { upsPhaseOutputPhaseEntry 12 } + + upsPhaseOutputPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output power in Watts, or -1 if it's + unsupported by this UPS." + ::= { upsPhaseOutputPhaseEntry 13 } + + upsPhaseOutputMaxPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum output power in Watts measured + since the last reset (upsPhaseResetMaxMinValues), or + -1 if it's unsupported by this UPS. + Sampled every 30 seconds." + ::= { upsPhaseOutputPhaseEntry 14 } + + upsPhaseOutputMinPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum output power in Watts measured + since the last reset (upsPhaseResetMaxMinValues), or + -1 if it's unsupported by this UPS. + Sampled every 30 seconds." + ::= { upsPhaseOutputPhaseEntry 15 } + + upsPhaseOutputPercentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The percentage of the UPS power capacity in Watts at + redundancy @ (n + x) presently being used on this + output phase, or -1 if it's unsupported by this UPS." + ::= { upsPhaseOutputPhaseEntry 16 } + + upsPhaseOutputMaxPercentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum percentage of the UPS power capacity + in Watts measured at redundancy @ (n + x) presently + being used on this output phase since the last + reset (upsPhaseResetMaxMinValues), or -1 if it's + unsupported by this UPS. Sampled every 30 seconds." + ::= { upsPhaseOutputPhaseEntry 17 } + + upsPhaseOutputMinPercentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum percentage of the UPS power capacity + in Watts measured at redundancy @ (n + x) presently + being used on this output phase since the last + reset (upsPhaseResetMaxMinValues), or -1 if it's + unsupported by this UPS. Sampled every 30 seconds." + ::= { upsPhaseOutputPhaseEntry 18 } + + upsPhaseOutputPowerFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Output power factor of the UPS in hundredth." + ::= { upsPhaseOutputPhaseEntry 19 } + +-- the upsOutletGroupStatus group + +upsOutletGroupStatusTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of outlet groups for the UPS." + ::= { upsOutletGroupStatus 1 } + +upsOutletGroupStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsOutletGroupStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting status of the outlet groups. The number of + entries is contained in the upsOutletGroupStatusTableSize OID." + ::= { upsOutletGroupStatus 2 } + +upsOutletGroupStatusEntry OBJECT-TYPE + SYNTAX UpsOutletGroupStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlet group status to get." + INDEX { upsOutletGroupStatusIndex} + ::= { upsOutletGroupStatusTable 1 } + +UpsOutletGroupStatusEntry ::= + SEQUENCE { + upsOutletGroupStatusIndex INTEGER, + upsOutletGroupStatusName DisplayString, + upsOutletGroupStatusGroupState INTEGER, + upsOutletGroupStatusCommandPending INTEGER, + upsOutletGroupStatusOutletType INTEGER + } + +upsOutletGroupStatusIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet group entry." + ::= { upsOutletGroupStatusEntry 1 } + +upsOutletGroupStatusName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the outlet group. This OID is provided + for informational purposes only. This value is set + by the upsOutletGroupConfigName OID." + ::= { upsOutletGroupStatusEntry 2 } + +upsOutletGroupStatusGroupState OBJECT-TYPE + SYNTAX INTEGER { + upsOutletGroupStatusOn (1), + upsOutletGroupStatusOff (2), + upsOutletGroupStatusUnknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the outlet group state. If the outlet + group is on, the upsOutletGroupStatusOn (1) value will be returned. If + the outlet group is off, the upsOutletGroupStatusOff (2) value will be + returned. If the state of the outlet group cannot be determined, the + upsOutletGroupStatusUnknown (3) value will be returned." + + ::= { upsOutletGroupStatusEntry 3 } + +upsOutletGroupStatusCommandPending OBJECT-TYPE + SYNTAX INTEGER { + upsOutletGroupCommandPending (1), + upsOutletGroupNoCommandPending (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the command pending + state of the outlet group. If a command is pending on the + outlet group, the upsOutletGroupCommandPending (1) value + will be returned. If there is not a command pending + on the outlet group, the upsOutletGroupNoCommandPending (2) + will be returned." + ::= { upsOutletGroupStatusEntry 4 } + +upsOutletGroupStatusOutletType OBJECT-TYPE + SYNTAX INTEGER { + upsSwitchedOutletGroup (1), + upsMainOutletGroup (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the type of outlet group. + If present in the system, the main outlet group is + 'unswitched' and must be on in order for any of the switched + outlet groups to be on. Conversely, if the main outlet group + is off, all the switched outlet groups must also be off. + Therefore, any commands made to the main outlet group that + turn it off will also be applied to all switched outlet + groups that are on, unless the state of a switched outlet + group prevents it, in which case the command will fail." + ::= { upsOutletGroupStatusEntry 5 } + +-- the upsOutletGroupConfig group + +upsOutletGroupConfigTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of outlet groups for the UPS." + ::= { upsOutletGroupConfig 1 } + +upsOutletGroupConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsOutletGroupConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The list of outlet groups to configure. The number of entries + is defined by the upsOutletGroupConfigTableSize OID." + ::= { upsOutletGroupConfig 2 } + +upsOutletGroupConfigEntry OBJECT-TYPE + SYNTAX UpsOutletGroupConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlet groups to configure." + INDEX { upsOutletGroupConfigIndex} + ::= { upsOutletGroupConfigTable 1 } + +UpsOutletGroupConfigEntry ::= + SEQUENCE { + upsOutletGroupConfigIndex INTEGER, + upsOutletGroupConfigName DisplayString, + upsOutletGroupConfigPowerOnDelay INTEGER, + upsOutletGroupConfigPowerOffDelay INTEGER, + upsOutletGroupConfigRebootDuration INTEGER, + upsOutletGroupConfigMinReturnRuntime INTEGER, + upsOutletGroupConfigOutletType INTEGER, + upsOutletGroupConfigLoadShedControlSkipOffDelay INTEGER, + upsOutletGroupConfigLoadShedControlAutoRestart INTEGER, + upsOutletGroupConfigLoadShedControlTimeOnBattery INTEGER, + upsOutletGroupConfigLoadShedControlRuntimeRemaining INTEGER, + upsOutletGroupConfigLoadShedControlInOverload INTEGER, + upsOutletGroupConfigLoadShedTimeOnBattery INTEGER, + upsOutletGroupConfigLoadShedRuntimeRemaining INTEGER + } + +upsOutletGroupConfigIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet group entry." + ::= { upsOutletGroupConfigEntry 1 } + +upsOutletGroupConfigName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the outlet group." + ::= { upsOutletGroupConfigEntry 2 } + +upsOutletGroupConfigPowerOnDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of time (seconds) the outlet group will delay + powering on when the delayed on, reboot, or shutdown command is + applied. Allowed values vary by UPS model. The value of -1 is + used for Never if supported by the UPS and the outlet group." + ::= { upsOutletGroupConfigEntry 3 } + +upsOutletGroupConfigPowerOffDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of time (seconds) the outlet group will delay + powering off when the delayed off, reboot, or shutdown command is + applied. Allowed values vary by UPS model. The value of -1 is + used for Never if supported by the UPS and the outlet group." + ::= { upsOutletGroupConfigEntry 4 } + +upsOutletGroupConfigRebootDuration OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "During a reboot sequence, power is turned off and then + back on. This OID defines the amount of time to wait + (seconds) after turning the power off, at the start + of the sequence, before initiating the power on sequence. + Allowed values vary by UPS model." + ::= { upsOutletGroupConfigEntry 5 } + +upsOutletGroupConfigMinReturnRuntime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "In an Outlet Group shutdown sequence, the Outlet Group cycles + power off then on. This OID defines the minimum amount of UPS + runtime (seconds) that is required in order to power the + Outlet Group on. Allowed values vary by UPS model." + ::= { upsOutletGroupConfigEntry 6 } + +upsOutletGroupConfigOutletType OBJECT-TYPE + SYNTAX INTEGER { + upsSwitchedOutletGroup (1), + upsMainOutletGroup (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the type of outlet group. + If present in the system, the main outlet group is + 'unswitched' and must be on in order for any of the switched + outlet groups to be on. Conversely, if the main outlet group + is off, all the switched outlet groups must also be off. + Therefore, any commands made to the main outlet group that + turn it off will also be applied to all switched outlet + groups that are on, unless the state of a switched outlet + group prevents it, in which case the command will fail." + ::= { upsOutletGroupConfigEntry 7 } + +upsOutletGroupConfigLoadShedControlSkipOffDelay OBJECT-TYPE + SYNTAX INTEGER { + upsOutletGroupConfigSkipOffDelay (1), + upsOutletGroupConfigUseOffDelay (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configures whether the outlet group's off delay setting + (upsOutletGroupConfigPowerOffDelay) will be used in a load + shedding situation, where applicable." + ::= { upsOutletGroupConfigEntry 8 } + +upsOutletGroupConfigLoadShedControlAutoRestart OBJECT-TYPE + SYNTAX INTEGER { + upsOutletGroupConfigAutoRestart (1), + upsOutletGroupConfigManualRestart (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configures whether the outlet group will automatically restart + after a load shedding situation, where applicable." + ::= { upsOutletGroupConfigEntry 9 } + +upsOutletGroupConfigLoadShedControlTimeOnBattery OBJECT-TYPE + SYNTAX INTEGER { + upsOutletGroupConfigDisableTimeOnBatteryLoadShed (1), + upsOutletGroupConfigEnableTimeOnBatteryLoadShed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configures whether the outlet group will load shed (turn off) + after the UPS's time on battery has exceeded the + upsOutletGroupConfigLoadShedTimeOnBattery OID setting. The + settings for upsOutletGroupConfigLoadShedControlSkipOffDelay + and upsOutletGroupConfigLoadShedControlAutoRestart are valid + for this load shed condition." + ::= { upsOutletGroupConfigEntry 10 } + +upsOutletGroupConfigLoadShedControlRuntimeRemaining OBJECT-TYPE + SYNTAX INTEGER { + upsOutletGroupConfigDisableRuntimeRemainingLoadShed (1), + upsOutletGroupConfigEnableRuntimeRemainingLoadShed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configures whether the outlet group will load shed (turn off) + when the UPS is on battery and the remaining runtime is less + than the upsOutletGroupConfigLoadShedRuntimeRemaining OID + setting. The settings for + upsOutletGroupConfigLoadShedControlSkipOffDelay and + upsOutletGroupConfigLoadShedControlAutoRestart are valid for + this load shed condition." + ::= { upsOutletGroupConfigEntry 11 } + +upsOutletGroupConfigLoadShedControlInOverload OBJECT-TYPE + SYNTAX INTEGER { + upsOutletGroupConfigDisableInOverloadLoadShed (1), + upsOutletGroupConfigEnableInOverloadLoadShed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configures whether the outlet group will load shed (turn off) + when the UPS is in an overload condition. The setting for + upsOutletGroupConfigLoadShedControlSkipOffDelay is valid for + this load shed condition. Returns -1 if not supported by this + outlet group." + ::= { upsOutletGroupConfigEntry 12 } + +upsOutletGroupConfigLoadShedTimeOnBattery OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When the UPS has been on battery for more time than this + value, the outlet group will turn off if this condition is + enabled by the upsOutletGroupConfigLoadShedControlTimeOnBattery + OID. Allowed values vary by UPS model." + ::= { upsOutletGroupConfigEntry 13 } + +upsOutletGroupConfigLoadShedRuntimeRemaining OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When the runtime remaining is less than this value, the outlet + group will turn off if this condition is enabled by the + upsOutletGroupConfigLoadShedControlRuntimeRemaining OID. + Allowed values vary by UPS model." + ::= { upsOutletGroupConfigEntry 14 } + +-- the upsOutletGroupControl group + +upsOutletGroupControlTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of outlet groups for the UPS." + ::= { upsOutletGroupControl 1 } + +upsOutletGroupControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsOutletGroupControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for control of individual outlet groups. The number of + entries is contained in the upsOutletGroupControlTableSize OID." + ::= { upsOutletGroupControl 2 } + +upsOutletGroupControlEntry OBJECT-TYPE + SYNTAX UpsOutletGroupControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlet group to control." + INDEX { upsOutletGroupControlIndex} + ::= { upsOutletGroupControlTable 1 } + +UpsOutletGroupControlEntry ::= + SEQUENCE { + upsOutletGroupControlIndex INTEGER, + upsOutletGroupControlName DisplayString, + upsOutletGroupControlCommand INTEGER, + upsOutletGroupControlOutletType INTEGER + } + +upsOutletGroupControlIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet group entry." + ::= { upsOutletGroupControlEntry 1 } + +upsOutletGroupControlName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the outlet group. This OID is provided + for informational purposes only. This value is set + by the upsOutletGroupConfigName OID." + ::= { upsOutletGroupControlEntry 2 } + +upsOutletGroupControlCommand OBJECT-TYPE + SYNTAX INTEGER { + upsOutletGroupImmediateOn (1), + upsOutletGroupImmediateOff (2), + upsOutletGroupImmediateRebootWithOrWithoutAC (3), + upsOutletGroupDelayedOn (4), + upsOutletGroupDelayedOff (5), + upsOutletGroupDelayedRebootWithOrWithoutAC (6), + upsOutletGroupCancelPendingCommand (7), + upsOutletGroupControlUnknown (8), + upsOutletGroupImmediateRebootShutdown (9), + upsOutletGroupDelayedRebootShutdown (10) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this variable will return the outlet group state. If the outlet + group is on, the upsOutletGroupImmediateOn (1) value will be returned. If + the outlet group is off, the upsOutletGroupImmediateOff (2) value will be + returned. + + If the state of the outlet group cannot be determined, the + upsOutletGroupControlUnknown (8) value will be returned. + + Setting this variable to upsOutletGroupImmediateOn (1) will turn the + outlet group on immediately. + + Setting this variable to upsOutletGroupImmediateOff (2) will turn the + outlet group off immediately. + + Setting this variable to upsOutletGroupImmediateRebootWithOrWithoutAC (3) + will turn the outlet group off immediately, wait the + upsOutletGroupConfigRebootDuration OID time, wait the + upsOutletGroupConfigPowerOnDelay OID, and then turn the outlet group on + regardless of the AC input power on the UPS. + + Setting this variable to upsOutletGroupDelayedOn (4) will turn the outlet + group on after the upsOutletGroupConfigPowerOnDelay OID has elapsed. + + Setting this variable to upsOutletGroupDelayedOff (5) will turn the outlet + group off after the upsOutletGroupConfigPowerOffDelay OID has elapsed. + + Setting this variable to upsOutletGroupDelayedRebootWithOrWithoutAC (6) + will turn the outlet group off after the upsOutletGroupConfigPowerOffDelay + OID has elapsed, wait the upsOutletGroupConfigRebootDuration OID time, wait + the upsOutletGroupConfigPowerOnDelay OID, and then turn the outlet group + on regardless of the AC input power on the UPS. + + Setting this variable to upsOutletGroupCancelPendingCommand (7) will + cause any pending command to this outlet group to be canceled. + + Setting this variable to upsOutletGroupImmediateRebootShutdown (9) will + turn the outlet group off immediately, wait for the AC power to return to normal + (a minimum of the upsOutletGroupConfigRebootDuration OID time), wait the + upsOutletGroupConfigPowerOnDelay OID time, and then turn the outlet + group on. + + Setting this variable to upsOutletGroupDelayedRebootShutdown (10) will + turn the outlet group off after the upsOutletGroupConfigPowerOffDelay OID + has elapsed, wait for the AC power to return to normal (a minimum of the + upsOutletGroupConfigRebootDuration OID time), wait the + upsOutletGroupConfigPowerOnDelay OID time, and then turn the outlet + group on. + + In systems with a main outlet group, commands to the main outlet group must + be performed with caution. It may be clearer to use the ups control commands + available from upsAdvControl... OIDs. If any command is made to the main + outlet group that will turn it off, one of two things will happen: + 1) If any switched outlet group is in a state that prevents this command + from occurring on the main outlet group, the command will be rejected. Note + that a switched outlet group being on without a command in progress is not a + state that normally prevents the command. + 2) The command will be accepted and applied to the main outlet group and all + switched outlet groups that are on. + + There is one additional special case for systems with a main outlet group. + If the main outlet group is off and a switched outlet group is commanded to + turn on, the on command will be applied to both the main outlet group and + that switched outlet group." + ::= { upsOutletGroupControlEntry 3 } + +upsOutletGroupControlOutletType OBJECT-TYPE + SYNTAX INTEGER { + upsSwitchedOutletGroup (1), + upsMainOutletGroup (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the type of outlet group. + If present in the system, the main outlet group is + 'unswitched' and must be on in order for any of the switched + outlet groups to be on. Conversely, if the main outlet group + is off, all the switched outlet groups must also be off. + Therefore, any commands made to the main outlet group that + turn it off will also be applied to all switched outlet + groups that are on, unless the state of a switched outlet + group prevents it, in which case the command will fail." + ::= { upsOutletGroupControlEntry 4 } + +-- the upsDiagnosticIM group + +upsDiagIMTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Intelligence Modules in or attached to the UPS." + ::= { upsDiagnosticIM 1 } + +upsDiagIMTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagIMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of individual Intelligence Modules. The number of + entries is contained in the upsDiagIMTableSize OID." + ::= { upsDiagnosticIM 2 } + +upsDiagIMEntry OBJECT-TYPE + SYNTAX UpsDiagIMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics and information of an Intelligence Module." + INDEX { upsDiagIMIndex} + ::= { upsDiagIMTable 1 } + +UpsDiagIMEntry ::= + SEQUENCE { + upsDiagIMIndex INTEGER, + upsDiagIMType INTEGER, + upsDiagIMStatus INTEGER, + upsDiagIMFirmwareRev DisplayString, + upsDiagIMSlaveFirmwareRev DisplayString, + upsDiagIMHardwareRev DisplayString, + upsDiagIMSerialNum DisplayString, + upsDiagIMManufactureDate DisplayString + } + +upsDiagIMIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Intelligence Module entry." + ::= { upsDiagIMEntry 1 } + +upsDiagIMType OBJECT-TYPE + SYNTAX INTEGER { + imUnknown (1), + imMIM (2), + imRIM (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of the Intelligence Module. + imUnknown(1) indicates the IM type is unknown. + imMIM(2) indicates the IM type is a Main Intelligence Module. + imRIM(3) indicates the IM type is Redundant Intelligence Module." + ::= { upsDiagIMEntry 2 } + +upsDiagIMStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + offOk (3), + onOk (4), + offFail (5), + onFail (6), + lostComm (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Intelligence Module. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + offOk(3) indicates the device status is off and OK. + onOk(4) indicates the device status is on and OK. + offFail(5) indicates the device status is off and failed. + onFail(6) indicates the device status is on and failed. + lostComm(7) indicates the device has lost communication." + ::= { upsDiagIMEntry 3 } + +upsDiagIMFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of the Intelligence Module." + ::= { upsDiagIMEntry 4 } + +upsDiagIMSlaveFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The slave firmware revision of the Intelligence Module." + ::= { upsDiagIMEntry 5 } + +upsDiagIMHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the Intelligence Module." + ::= { upsDiagIMEntry 6 } + +upsDiagIMSerialNum OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the Intelligence Module." + ::= { upsDiagIMEntry 7 } + +upsDiagIMManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The manufacture date of the Intelligence Module." + ::= { upsDiagIMEntry 8 } + +-- the upsDiagnosticPowerModules group + +upsDiagPMTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum number of Power Modules supported by the UPS." + ::= { upsDiagnosticPowerModules 1 } + +upsDiagPMTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagPMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of Individual Power modules. The number of + entries is contained in the upsDiagPMTableSize OID." + ::= { upsDiagnosticPowerModules 2 } + +upsDiagPMEntry OBJECT-TYPE + SYNTAX UpsDiagPMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of an Power Module." + INDEX { upsDiagPMIndex} + ::= { upsDiagPMTable 1 } + +UpsDiagPMEntry ::= + SEQUENCE { + upsDiagPMIndex INTEGER, + upsDiagPMStatus INTEGER, + upsDiagPMFirmwareRev DisplayString, + upsDiagPMHardwareRev DisplayString, + upsDiagPMSerialNum DisplayString, + upsDiagPMManufactureDate DisplayString + } + +upsDiagPMIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Power Module entry." + ::= { upsDiagPMEntry 1 } + +upsDiagPMStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + offOk (3), + onOk (4), + offFail (5), + onFail (6), + lostComm (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Power Module. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + offOk(3) indicates the device status is off and OK. + onOk(4) indicates the device status is on and OK. + offFail(5) indicates the device status is off and failed. + onFail(6) indicates the device status is on and failed. + lostComm(7) indicates the device has lost communication." + ::= { upsDiagPMEntry 2 } + +upsDiagPMFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of the Power Module." + ::= { upsDiagPMEntry 3 } + +upsDiagPMHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the Power Module." + ::= { upsDiagPMEntry 4 } + +upsDiagPMSerialNum OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the Power Module." + ::= { upsDiagPMEntry 5 } + +upsDiagPMManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The manufacture date of the Power Module." + ::= { upsDiagPMEntry 6 } + +-- the upsDiagnosticBatteries group + +upsDiagBatteryTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum number of batteries supported by the UPS." + ::= { upsDiagnosticBatteries 1 } + +upsDiagBatteryTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagBatteryEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of individual batteries. The number of + entries is contained in the upsDiagBattTableSize OID." + ::= { upsDiagnosticBatteries 2 } + +upsDiagBatteryEntry OBJECT-TYPE + SYNTAX UpsDiagBatteryEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of a battery." + INDEX { upsDiagBatteryIndex} + ::= { upsDiagBatteryTable 1 } + +UpsDiagBatteryEntry ::= + SEQUENCE { + upsDiagBatteryFrameIndex INTEGER, + upsDiagBatteryIndex INTEGER, + upsDiagBatteryStatus INTEGER, + upsDiagBatterySerialNumber DisplayString, + upsDiagBatteryFirmwareRev DisplayString, + upsDiagBatteryManufactureDate DisplayString, + upsDiagBatteryType DisplayString, + upsDiagBatteryFramePresent INTEGER, + upsDiagBatteryFrameTemperature INTEGER + } + +upsDiagBatteryFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the battery frame entry. + Frame 0 indicates the Main frame. Extended Run (XR) frames + start from index 1." + ::= { upsDiagBatteryEntry 1 } + +upsDiagBatteryIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the battery entry." + ::= { upsDiagBatteryEntry 2 } + +upsDiagBatteryStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + ok (3), + failed (4), + highTemperature (5), + replaceImmediately (6), + lowCapacity (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the battery. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + ok(3) indicates the battery status is OK. + failed(4) indicates the battery status is failed. + highTemperature(5) indicates the battery has a high temperature condition. + replaceImmediately(6) indicates the battery must be replaced immediately. + lowCapacity(7) indicates the battery has a low capacity." + ::= { upsDiagBatteryEntry 3 } + +upsDiagBatterySerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the battery." + ::= { upsDiagBatteryEntry 4 } + +upsDiagBatteryFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of the battery." + ::= { upsDiagBatteryEntry 5 } + +upsDiagBatteryManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The manufacture date of the battery." + ::= { upsDiagBatteryEntry 6 } + +upsDiagBatteryType OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery type or rating for the battery." + ::= { upsDiagBatteryEntry 7 } + + + upsDiagBatteryFramePresent OBJECT-TYPE + SYNTAX INTEGER { + notPresent(0), + present(1) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery frame/cabinet status. + 0 indicates frame/cabinet is not present. + 1 indicates frame/cabinet is present." + ::= { upsDiagBatteryEntry 8 } + + upsDiagBatteryFrameTemperature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery frame/cabinet temperature in tenths of degrees celsius. + If the frame/cabinet is not present, this variable is set to (-1)." + ::= { upsDiagBatteryEntry 9 } + + +-- the upsDiagnosticSubsystem group + +upsDiagSubSysFrameTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of frames attached to the UPS including the Main frame." + ::= { upsDiagnosticSubsystem 1 } + +upsDiagSubSysFrameTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagSubSysFrameEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of individual XR Frames." + ::= { upsDiagnosticSubsystem 2 } + +upsDiagSubSysFrameEntry OBJECT-TYPE + SYNTAX UpsDiagSubSysFrameEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of an XR Frame." + INDEX { upsDiagSubSysFrameIndex} + ::= { upsDiagSubSysFrameTable 1 } + +UpsDiagSubSysFrameEntry ::= + SEQUENCE { + upsDiagSubSysFrameIndex INTEGER, + upsDiagSubSysFrameType INTEGER, + upsDiagSubSysFrameFirmwareRev DisplayString, + upsDiagSubSysFrameHardwareRev DisplayString, + upsDiagSubSysFrameSerialNum DisplayString, + upsDiagSubSysFrameManufactureDate DisplayString + } + +upsDiagSubSysFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frame index entry." + ::= { upsDiagSubSysFrameEntry 1 } + +upsDiagSubSysFrameType OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + frameTypeMain (3), + frameTypeXR (4), + frameTypeLXR (5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of Frame. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + frameTypeMain(3) indicates the frame type is the Main Frame. + frameTypeXR(4) indicates the frame type is an XR Frame. + frameTypeLXR(5) indicates the frame type is an LXR Frame." + ::= { upsDiagSubSysFrameEntry 2 } + +upsDiagSubSysFrameFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of the frame." + ::= { upsDiagSubSysFrameEntry 3 } + +upsDiagSubSysFrameHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the frame." + ::= { upsDiagSubSysFrameEntry 4 } + +upsDiagSubSysFrameSerialNum OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the frame." + ::= { upsDiagSubSysFrameEntry 5 } + +upsDiagSubSysFrameManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The manufacture date of the frame." + ::= { upsDiagSubSysFrameEntry 6 } + +upsDiagSubSysIntBypSwitchTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Internal Bypass switches attached to the UPS." + ::= { upsDiagnosticSubsystem 3 } + +upsDiagSubSysIntBypSwitchTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagSubSysIntBypSwitchEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of the Internal Bypass Switch." + ::= { upsDiagnosticSubsystem 4 } + +upsDiagSubSysIntBypSwitchEntry OBJECT-TYPE + SYNTAX UpsDiagSubSysIntBypSwitchEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of the Internal Bypass Switch." + INDEX { upsDiagSubSysIntBypSwitchIndex} + ::= { upsDiagSubSysIntBypSwitchTable 1 } + +UpsDiagSubSysIntBypSwitchEntry ::= + SEQUENCE { + upsDiagSubSysIntBypSwitchFrameIndex INTEGER, + upsDiagSubSysIntBypSwitchIndex INTEGER, + upsDiagSubSysIntBypSwitchStatus INTEGER, + upsDiagSubSysIntBypSwitchFirmwareRev DisplayString, + upsDiagSubSysIntBypSwitchHardwareRev DisplayString, + upsDiagSubSysIntBypSwitchSerialNum DisplayString, + upsDiagSubSysIntBypSwitchManufactureDate DisplayString + } + +upsDiagSubSysIntBypSwitchFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frame index entry." + ::= { upsDiagSubSysIntBypSwitchEntry 1 } + +upsDiagSubSysIntBypSwitchIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Internal Bypass Switch index entry." + ::= { upsDiagSubSysIntBypSwitchEntry 2 } + +upsDiagSubSysIntBypSwitchStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + offOk (3), + onOk (4), + offFail (5), + onFail (6), + lostComm (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Internal Bypass Switch status. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + offOk(3) indicates the device status is off and OK. + onOk(4) indicates the device status is on and OK. + offFail(5) indicates the device status is off and failed. + onFail(6) indicates the device status is on and failed. + lostComm(7) indicates the device has lost communication." + ::= { upsDiagSubSysIntBypSwitchEntry 3 } + +upsDiagSubSysIntBypSwitchFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of the Internal Bypass Switch." + ::= { upsDiagSubSysIntBypSwitchEntry 4 } + +upsDiagSubSysIntBypSwitchHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the Internal Bypass Switch." + ::= { upsDiagSubSysIntBypSwitchEntry 5 } + +upsDiagSubSysIntBypSwitchSerialNum OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the Internal Bypass Switch." + ::= { upsDiagSubSysIntBypSwitchEntry 6 } + +upsDiagSubSysIntBypSwitchManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The manufacture date of the Internal Bypass Switch." + ::= { upsDiagSubSysIntBypSwitchEntry 7 } + +upsDiagSubSysBattMonitorTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Battery Monitor Boards attached to the UPS." + ::= { upsDiagnosticSubsystem 5 } + +upsDiagSubSysBattMonitorTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagSubSysBattMonitorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of the Battery Monitor Board." + ::= { upsDiagnosticSubsystem 6 } + +upsDiagSubSysBattMonitorEntry OBJECT-TYPE + SYNTAX UpsDiagSubSysBattMonitorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of the Battery Monitor Board." + INDEX { upsDiagSubSysBattMonitorIndex} + ::= { upsDiagSubSysBattMonitorTable 1 } + +UpsDiagSubSysBattMonitorEntry ::= + SEQUENCE { + upsDiagSubSysBattMonitorFrameIndex INTEGER, + upsDiagSubSysBattMonitorIndex INTEGER, + upsDiagSubSysBattMonitorStatus INTEGER, + upsDiagSubSysBattMonitorFirmwareRev DisplayString, + upsDiagSubSysBattMonitorHardwareRev DisplayString, + upsDiagSubSysBattMonitorSerialNum DisplayString, + upsDiagSubSysBattMonitorManufactureDate DisplayString + } + +upsDiagSubSysBattMonitorFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frame index entry." + ::= { upsDiagSubSysBattMonitorEntry 1 } + +upsDiagSubSysBattMonitorIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the Battery Monitor Board." + ::= { upsDiagSubSysBattMonitorEntry 2 } + +upsDiagSubSysBattMonitorStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + offOk (3), + onOk (4), + offFail (5), + onFail (6), + lostComm (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Battery Monitor Board. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + offOk(3) indicates the device status is off and OK. + onOk(4) indicates the device status is on and OK. + offFail(5) indicates the device status is off and failed. + onFail(6) indicates the device status is on and failed. + lostComm(7) indicates the device has lost communication." + ::= { upsDiagSubSysBattMonitorEntry 3 } + +upsDiagSubSysBattMonitorFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of the Battery Monitor Board." + ::= { upsDiagSubSysBattMonitorEntry 4 } + +upsDiagSubSysBattMonitorHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the Battery Monitor Board." + ::= { upsDiagSubSysBattMonitorEntry 5 } + +upsDiagSubSysBattMonitorSerialNum OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the Battery Monitor Board." + ::= { upsDiagSubSysBattMonitorEntry 6 } + +upsDiagSubSysBattMonitorManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date of the manufacture for the Battery Monitor Board." + ::= { upsDiagSubSysBattMonitorEntry 7 } + +upsDiagSubSysExternalSwitchGearTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of External Switch Gears attached to the UPS." + ::= { upsDiagnosticSubsystem 7 } + +upsDiagSubSysExternalSwitchGearTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagSubSysExternalSwitchGearEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of the individual External Switch Gear." + ::= { upsDiagnosticSubsystem 8 } + +upsDiagSubSysExternalSwitchGearEntry OBJECT-TYPE + SYNTAX UpsDiagSubSysExternalSwitchGearEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of an individual External Switch Gear." + INDEX { upsDiagSubSysExternalSwitchGearIndex} + ::= { upsDiagSubSysExternalSwitchGearTable 1 } + +UpsDiagSubSysExternalSwitchGearEntry ::= + SEQUENCE { + upsDiagSubSysExternalSwitchGearFrameIndex INTEGER, + upsDiagSubSysExternalSwitchGearIndex INTEGER, + upsDiagSubSysExternalSwitchGearStatus INTEGER, + upsDiagSubSysExternalSwitchGearFirmwareRev DisplayString, + upsDiagSubSysExternalSwitchGearHardwareRev DisplayString, + upsDiagSubSysExternalSwitchGearSerialNum DisplayString, + upsDiagSubSysExternalSwitchGearManufactureDate DisplayString + } + +upsDiagSubSysExternalSwitchGearFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frame index entry." + ::= { upsDiagSubSysExternalSwitchGearEntry 1 } + +upsDiagSubSysExternalSwitchGearIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the External Switch Gear." + ::= { upsDiagSubSysExternalSwitchGearEntry 2 } + +upsDiagSubSysExternalSwitchGearStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + offOk (3), + onOk (4), + offFail (5), + onFail (6), + lostComm (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the External Switch Gear. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + offOk(3) indicates the device status is off and OK. + onOk(4) indicates the device status is on and OK. + offFail(5) indicates the device status is off and failed. + onFail(6) indicates the device status is on and failed. + lostComm(7) indicates the device has lost communication." + ::= { upsDiagSubSysExternalSwitchGearEntry 3 } + +upsDiagSubSysExternalSwitchGearFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of the External Switch Gear monitor card." + ::= { upsDiagSubSysExternalSwitchGearEntry 4 } + +upsDiagSubSysExternalSwitchGearHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the External Switch Gear monitor card." + ::= { upsDiagSubSysExternalSwitchGearEntry 5 } + +upsDiagSubSysExternalSwitchGearSerialNum OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the External Switch Gear monitor card." + ::= { upsDiagSubSysExternalSwitchGearEntry 6 } + +upsDiagSubSysExternalSwitchGearManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date of the manufacture for the External Switch Gear monitor card." + ::= { upsDiagSubSysExternalSwitchGearEntry 7 } + +upsDiagSubSysDisplayInterfaceCardTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Display Interface Cards attached to the UPS." + ::= { upsDiagnosticSubsystem 9 } + +upsDiagSubSysDisplayInterfaceCardTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagSubSysDisplayInterfaceCardEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of individual Display Interface Cards." + ::= { upsDiagnosticSubsystem 10 } + +upsDiagSubSysDisplayInterfaceCardEntry OBJECT-TYPE + SYNTAX UpsDiagSubSysDisplayInterfaceCardEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of a Display Interface Card." + INDEX { upsDiagSubSysDisplayInterfaceCardIndex} + ::= { upsDiagSubSysDisplayInterfaceCardTable 1 } + +UpsDiagSubSysDisplayInterfaceCardEntry ::= + SEQUENCE { + upsDiagSubSysDisplayInterfaceCardFrameIndex INTEGER, + upsDiagSubSysDisplayInterfaceCardIndex INTEGER, + upsDiagSubSysDisplayInterfaceCardStatus INTEGER + } + +upsDiagSubSysDisplayInterfaceCardFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frame index entry." + ::= { upsDiagSubSysDisplayInterfaceCardEntry 1 } + +upsDiagSubSysDisplayInterfaceCardIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the Display Interface Card." + ::= { upsDiagSubSysDisplayInterfaceCardEntry 2 } + +upsDiagSubSysDisplayInterfaceCardStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + offOk (3), + onOk (4), + offFail (5), + onFail (6), + lostComm (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Display Interface Card. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + offOk(3) indicates the device status is off and OK. + onOk(4) indicates the device status is on and OK. + offFail(5) indicates the device status is off and failed. + onFail(6) indicates the device status is on and failed. + lostComm(7) indicates the device has lost communication." + ::= { upsDiagSubSysDisplayInterfaceCardEntry 3 } + +upsDiagSubSysDCCircuitBreakerTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC Circuit Breakers attached to the UPS." + ::= { upsDiagnosticSubsystem 11 } + +upsDiagSubSysDCCircuitBreakerTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagSubSysDCCircuitBreakerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of individual DC Circuit Breakers." + ::= { upsDiagnosticSubsystem 12 } + +upsDiagSubSysDCCircuitBreakerEntry OBJECT-TYPE + SYNTAX UpsDiagSubSysDCCircuitBreakerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of a DC Circuit Breaker." + INDEX { upsDiagSubSysDCCircuitBreakerIndex} + ::= { upsDiagSubSysDCCircuitBreakerTable 1 } + +UpsDiagSubSysDCCircuitBreakerEntry ::= + SEQUENCE { + upsDiagSubSysDCCircuitBreakerFrameIndex INTEGER, + upsDiagSubSysDCCircuitBreakerIndex INTEGER, + upsDiagSubSysDCCircuitBreakerStatus INTEGER + } + +upsDiagSubSysDCCircuitBreakerFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frame index entry." + ::= { upsDiagSubSysDCCircuitBreakerEntry 1 } + +upsDiagSubSysDCCircuitBreakerIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the DC Circuit Breaker." + ::= { upsDiagSubSysDCCircuitBreakerEntry 2 } + +upsDiagSubSysDCCircuitBreakerStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + opened (3), + closed (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the DC Circuit Breaker. + unknown(1) indicates the circuit breaker status is unknown. + notInstalled(2) indicates the circuit breaker is not installed. + opened(3) indicates the circuit breaker is opened. + closed(4) indicates the circuit breaker is closed." + ::= { upsDiagSubSysDCCircuitBreakerEntry 3 } + +upsDiagSubSysSystemPowerSupplyTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of System Power Supplies attached to the UPS." + ::= { upsDiagnosticSubsystem 13 } + +upsDiagSubSysSystemPowerSupplyTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagSubSysSystemPowerSupplyEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of individual System Power Supplies." + ::= { upsDiagnosticSubsystem 14 } + +upsDiagSubSysSystemPowerSupplyEntry OBJECT-TYPE + SYNTAX UpsDiagSubSysSystemPowerSupplyEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of a System Power Supply." + INDEX { upsDiagSubSysSystemPowerSupplyIndex} + ::= { upsDiagSubSysSystemPowerSupplyTable 1 } + +UpsDiagSubSysSystemPowerSupplyEntry ::= + SEQUENCE { + upsDiagSubSysSystemPowerSupplyFrameIndex INTEGER, + upsDiagSubSysSystemPowerSupplyIndex INTEGER, + upsDiagSubSysSystemPowerSupplyStatus INTEGER, + upsDiagSubSysSystemPowerSupplyFirmwareRev DisplayString, + upsDiagSubSysSystemPowerSupplyHardwareRev DisplayString, + upsDiagSubSysSystemPowerSupplySerialNum DisplayString, + upsDiagSubSysSystemPowerSupplyManufactureDate DisplayString + } + +upsDiagSubSysSystemPowerSupplyFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frame index entry." + ::= { upsDiagSubSysSystemPowerSupplyEntry 1 } + +upsDiagSubSysSystemPowerSupplyIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of a System Power Supply." + ::= { upsDiagSubSysSystemPowerSupplyEntry 2 } + +upsDiagSubSysSystemPowerSupplyStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + offOk (3), + onOk (4), + offFail (5), + onFail (6), + lostComm (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the System Power Supply. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + offOk(3) indicates the device status is off and OK. + onOk(4) indicates the device status is on and OK. + offFail(5) indicates the device status is off and failed. + onFail(6) indicates the device status is on and failed. + lostComm(7) indicates the device has lost communication." + ::= { upsDiagSubSysSystemPowerSupplyEntry 3 } + +upsDiagSubSysSystemPowerSupplyFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of the System Power Supply monitor card." + ::= { upsDiagSubSysSystemPowerSupplyEntry 4 } + +upsDiagSubSysSystemPowerSupplyHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the System Power Supply monitor card." + ::= { upsDiagSubSysSystemPowerSupplyEntry 5 } + +upsDiagSubSysSystemPowerSupplySerialNum OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the System Power Supply monitor card." + ::= { upsDiagSubSysSystemPowerSupplyEntry 6 } + +upsDiagSubSysSystemPowerSupplyManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date of the manufacture for the System Power Supply monitor card." + ::= { upsDiagSubSysSystemPowerSupplyEntry 7 } + +upsDiagSubSysXRCommunicationCardTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of XR Communication Cards attached to the UPS." + ::= { upsDiagnosticSubsystem 15 } + +upsDiagSubSysXRCommunicationCardTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagSubSysXRCommunicationCardEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of individual XR Communication Cards." + ::= { upsDiagnosticSubsystem 16 } + +upsDiagSubSysXRCommunicationCardEntry OBJECT-TYPE + SYNTAX UpsDiagSubSysXRCommunicationCardEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of an XR Communication Card." + INDEX { upsDiagSubSysXRCommunicationCardIndex} + ::= { upsDiagSubSysXRCommunicationCardTable 1 } + +UpsDiagSubSysXRCommunicationCardEntry ::= + SEQUENCE { + upsDiagSubSysXRCommunicationCardFrameIndex INTEGER, + upsDiagSubSysXRCommunicationCardIndex INTEGER, + upsDiagSubSysXRCommunicationCardStatus INTEGER, + upsDiagSubSysXRCommunicationCardFirmwareRev DisplayString, + upsDiagSubSysXRCommunicationCardSerialNum DisplayString + + } + +upsDiagSubSysXRCommunicationCardFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frame index entry." + ::= { upsDiagSubSysXRCommunicationCardEntry 1 } + +upsDiagSubSysXRCommunicationCardIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of an XR Communication Card." + ::= { upsDiagSubSysXRCommunicationCardEntry 2 } + +upsDiagSubSysXRCommunicationCardStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + offOk (3), + onOk (4), + offFail (5), + onFail (6), + lostComm (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the XR Communication Card. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + offOk(3) indicates the device status is off and OK. + onOk(4) indicates the device status is on and OK. + offFail(5) indicates the device status is off and failed. + onFail(6) indicates the device status is on and failed. + lostComm(7) indicates the device has lost communication." + ::= { upsDiagSubSysXRCommunicationCardEntry 3 } + +upsDiagSubSysXRCommunicationCardFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of the XR Communication card." + ::= { upsDiagSubSysXRCommunicationCardEntry 4 } + +upsDiagSubSysXRCommunicationCardSerialNum OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the XR Communication card." + ::= { upsDiagSubSysXRCommunicationCardEntry 5 } + +upsDiagSubSysExternalPowerFrameBoardTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of External Power Frame Boards attached to the UPS." + ::= { upsDiagnosticSubsystem 17 } + +upsDiagSubSysExternalPowerFrameBoardTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagSubSysExternalPowerFrameBoardEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of individual External Power Frame Boards." + ::= { upsDiagnosticSubsystem 18 } + +upsDiagSubSysExternalPowerFrameBoardEntry OBJECT-TYPE + SYNTAX UpsDiagSubSysExternalPowerFrameBoardEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of an External Power Frame Board." + INDEX { upsDiagSubSysExternalPowerFrameBoardIndex} + ::= { upsDiagSubSysExternalPowerFrameBoardTable 1 } + +UpsDiagSubSysExternalPowerFrameBoardEntry ::= + SEQUENCE { + upsDiagSubSysExternalPowerFrameBoardFrameIndex INTEGER, + upsDiagSubSysExternalPowerFrameBoardIndex INTEGER, + upsDiagSubSysExternalPowerFrameBoardStatus INTEGER + } + +upsDiagSubSysExternalPowerFrameBoardFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frame index entry." + ::= { upsDiagSubSysExternalPowerFrameBoardEntry 1 } + +upsDiagSubSysExternalPowerFrameBoardIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of an External Power Frame Board." + ::= { upsDiagSubSysExternalPowerFrameBoardEntry 2 } + +upsDiagSubSysExternalPowerFrameBoardStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + offOk (3), + onOk (4), + offFail (5), + onFail (6), + lostComm (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the External Power Frame Board. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + offOk(3) indicates the device status is off and OK. + onOk(4) indicates the device status is on and OK. + offFail(5) indicates the device status is off and failed. + onFail(6) indicates the device status is on and failed. + lostComm(7) indicates the device has lost communication." + ::= { upsDiagSubSysExternalPowerFrameBoardEntry 3 } + +upsDiagSubSysChargerTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Chargers attached to the UPS." + ::= { upsDiagnosticSubsystem 19 } + + upsDiagSubSysChargerTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagSubSysChargerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of individual chargers." + ::= { upsDiagnosticSubsystem 20 } + +upsDiagSubSysChargerEntry OBJECT-TYPE + SYNTAX UpsDiagSubSysChargerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of a charger." + INDEX { upsDiagSubSysChargerIndex} + ::= { upsDiagSubSysChargerTable 1 } + +UpsDiagSubSysChargerEntry ::= + SEQUENCE { + upsDiagSubSysChargerFrameIndex INTEGER, + upsDiagSubSysChargerIndex INTEGER, + upsDiagSubSysChargerStatus INTEGER + } + +upsDiagSubSysChargerFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frame index entry." + ::= { upsDiagSubSysChargerEntry 1 } + +upsDiagSubSysChargerIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of a charger." + ::= { upsDiagSubSysChargerEntry 2 } + +upsDiagSubSysChargerStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + offOk (3), + onOk (4), + offFail (5), + onFail (6), + lostComm (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Charger. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + offOk(3) indicates the device status is off and OK. + onOk(4) indicates the device status is on and OK. + offFail(5) indicates the device status is off and failed. + onFail(6) indicates the device status is on and failed. + lostComm(7) indicates the device has lost communication." + ::= { upsDiagSubSysChargerEntry 3 } + +upsDiagSubSysInverterTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Inverters attached to the UPS." + ::= { upsDiagnosticSubsystem 21 } + +upsDiagSubSysInverterTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagSubSysInverterEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of individual Inverters." + ::= { upsDiagnosticSubsystem 22 } + +upsDiagSubSysInverterEntry OBJECT-TYPE + SYNTAX UpsDiagSubSysInverterEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of an Inverter." + INDEX { upsDiagSubSysInverterIndex} + ::= { upsDiagSubSysInverterTable 1 } + +UpsDiagSubSysInverterEntry ::= + SEQUENCE { + upsDiagSubSysInverterFrameIndex INTEGER, + upsDiagSubSysInverterIndex INTEGER, + upsDiagSubSysInverterStatus INTEGER, + upsDiagSubSysInverterFirmwareRev DisplayString, + upsDiagSubSysInverterHardwareRev DisplayString, + upsDiagSubSysInverterSerialNum DisplayString, + upsDiagSubSysInverterManufactureDate DisplayString + } + +upsDiagSubSysInverterFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frame index entry." + ::= { upsDiagSubSysInverterEntry 1 } + +upsDiagSubSysInverterIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of an Inverter." + ::= { upsDiagSubSysInverterEntry 2 } + +upsDiagSubSysInverterStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + offOk (3), + onOk (4), + offFail (5), + onFail (6), + lostComm (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Inverter. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + offOk(3) indicates the device status is off and OK. + onOk(4) indicates the device status is on and OK. + offFail(5) indicates the device status is off and failed. + onFail(6) indicates the device status is on and failed. + lostComm(7) indicates the device has lost communication." + ::= { upsDiagSubSysInverterEntry 3 } + +upsDiagSubSysInverterFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of the Inverter monitor." + ::= { upsDiagSubSysInverterEntry 4 } + +upsDiagSubSysInverterHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the Inverter monitor." + ::= { upsDiagSubSysInverterEntry 5 } + +upsDiagSubSysInverterSerialNum OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the Inverter monitor." + ::= { upsDiagSubSysInverterEntry 6 } + +upsDiagSubSysInverterManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date of manufacture for the Inverter monitor." + ::= { upsDiagSubSysInverterEntry 7 } + +upsDiagSubSysPowerFactorCorrectionTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Power Factor Correction devices attached to the UPS." + ::= { upsDiagnosticSubsystem 23 } + +upsDiagSubSysPowerFactorCorrectionTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagSubSysPowerFactorCorrectionEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of individual PowerFactorCorrections." + ::= { upsDiagnosticSubsystem 24 } + +upsDiagSubSysPowerFactorCorrectionEntry OBJECT-TYPE + SYNTAX UpsDiagSubSysPowerFactorCorrectionEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of a Power Factor Correction." + INDEX { upsDiagSubSysPowerFactorCorrectionIndex} + ::= { upsDiagSubSysPowerFactorCorrectionTable 1 } + +UpsDiagSubSysPowerFactorCorrectionEntry ::= + SEQUENCE { + upsDiagSubSysPowerFactorCorrectionFrameIndex INTEGER, + upsDiagSubSysPowerFactorCorrectionIndex INTEGER, + upsDiagSubSysPowerFactorCorrectionStatus INTEGER, + upsDiagSubSysPowerFactorCorrectionFirmwareRev DisplayString, + upsDiagSubSysPowerFactorCorrectionHardwareRev DisplayString, + upsDiagSubSysPowerFactorCorrectionSerialNum DisplayString, + upsDiagSubSysPowerFactorCorrectionManufactureDate DisplayString + } + +upsDiagSubSysPowerFactorCorrectionFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frame index entry." + ::= { upsDiagSubSysPowerFactorCorrectionEntry 1 } + +upsDiagSubSysPowerFactorCorrectionIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of a Power Factor Correction." + ::= { upsDiagSubSysPowerFactorCorrectionEntry 2 } + +upsDiagSubSysPowerFactorCorrectionStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + offOk (3), + onOk (4), + offFail (5), + onFail (6), + lostComm (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Power Factor Correction. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + offOk(3) indicates the device status is off and OK. + onOk(4) indicates the device status is on and OK. + offFail(5) indicates the device status is off and failed. + onFail(6) indicates the device status is on and failed. + lostComm(7) indicates the device has lost communication." + ::= { upsDiagSubSysPowerFactorCorrectionEntry 3 } + +upsDiagSubSysPowerFactorCorrectionFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of the Power Factor Correction monitor." + ::= { upsDiagSubSysPowerFactorCorrectionEntry 4 } + +upsDiagSubSysPowerFactorCorrectionHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the Power Factor Correction monitor." + ::= { upsDiagSubSysPowerFactorCorrectionEntry 5 } + +upsDiagSubSysPowerFactorCorrectionSerialNum OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the Power Factor Correction monitor." + ::= { upsDiagSubSysPowerFactorCorrectionEntry 6 } + +upsDiagSubSysPowerFactorCorrectionManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date of the manufacture for the Power Factor Correction monitor." + ::= { upsDiagSubSysPowerFactorCorrectionEntry 7 } + +upsDiagSubSysNetworkComCardTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Network Communication Cards attached to the UPS." + ::= { upsDiagnosticSubsystem 25 } + +upsDiagSubSysNetworkComCardTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagSubSysNetworkComCardEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting diagnostics information of an individual Network Communication Card." + ::= { upsDiagnosticSubsystem 26 } + +upsDiagSubSysNetworkComCardEntry OBJECT-TYPE + SYNTAX UpsDiagSubSysNetworkComCardEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of a Network Communication Card." + INDEX { upsDiagSubSysNetworkComCardIndex} + ::= { upsDiagSubSysNetworkComCardTable 1 } + +UpsDiagSubSysNetworkComCardEntry ::= + SEQUENCE { + upsDiagSubSysNetworkComCardIndex INTEGER, + upsDiagSubSysNetworkComCardModelNumber DisplayString, + upsDiagSubSysNetworkComCardSerialNumber DisplayString, + upsDiagSubSysNetworkComCardDateOfManufacture DisplayString, + upsDiagSubSysNetworkComCardHardwareRev DisplayString, + upsDiagSubSysNetworkComCardFirmwareAppRev DisplayString, + upsDiagSubSysNetworkComCardFirmwareAppOSRev DisplayString + } + +upsDiagSubSysNetworkComCardIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The UPS network and display interface communication card index entry." + ::= { upsDiagSubSysNetworkComCardEntry 1 } + +upsDiagSubSysNetworkComCardModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the model number of the UPS network and display interface communication card. + This value is set at the factory." + ::= { upsDiagSubSysNetworkComCardEntry 2 } + +upsDiagSubSysNetworkComCardSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the serial number of the UPS network and display interface communication card. + This value is set at the factory." + ::= { upsDiagSubSysNetworkComCardEntry 3 } + +upsDiagSubSysNetworkComCardDateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date when the UPS network and display interface communication card was manufactured in mm/dd/yyyy format. + This value is set at the factory." + ::= { upsDiagSubSysNetworkComCardEntry 4 } + +upsDiagSubSysNetworkComCardHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the UPS network and display interface communication card. + This value is set at the factory." + ::= { upsDiagSubSysNetworkComCardEntry 5 } + +upsDiagSubSysNetworkComCardFirmwareAppRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ID string identifying the application firmware revision of the + UPS network and display interface communication card." + ::= { upsDiagSubSysNetworkComCardEntry 6 } + +upsDiagSubSysNetworkComCardFirmwareAppOSRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ID string identifying the application operating system firmware revision of the + UPS network and display interface communication card." + ::= { upsDiagSubSysNetworkComCardEntry 7 } + +-- the upsDiagnosticExternalDevices group + +upsDiagSwitchGearStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + ok (3), + fail (4), + lostComm (5), + overtemp (6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Switch Gear. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + ok(3) indicates the device status is OK. + fail(4) indicates the device status has failed. + lostComm(5) indicates the device has lost communication. + overtemp(6) indicates the device has an over temperature condition." + ::= { upsDiagSwitchGear 1 } + +upsDiagSwitchGearInputSwitchStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + opened (3), + closed (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Switch Gear Input Switch. + unknown(1) indicates the switch status is unknown. + notInstalled(2) indicates the switch is not installed. + opened(3) indicates the switch is opened. + closed(4) indicates the switch is closed." + ::= { upsDiagSwitchGear 2 } + +upsDiagSwitchGearOutputSwitchStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + opened (3), + closed (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Switch Gear Output Switch. + unknown(1) indicates the switch status is unknown. + notInstalled(2) indicates the switch is not installed. + opened(3) indicates the switch is opened. + closed(4) indicates the switch is closed." + ::= { upsDiagSwitchGear 3 } + +upsDiagSwitchGearBypassSwitchStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + opened (3), + closed (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Switch Gear Bypass Switch. + unknown(1) indicates the switch status is unknown. + notInstalled(2) indicates the switch is not installed. + opened(3) indicates the switch is opened. + closed(4) indicates the switch is closed." + ::= { upsDiagSwitchGear 4 } + +upsDiagSwitchGearBypassInputSwitchStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + opened (3), + closed (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Switch Gear Bypass Input Switch. + unknown(1) indicates the switch status is unknown. + notInstalled(2) indicates the switch is not installed. + opened(3) indicates the switch is opened. + closed(4) indicates the switch is closed." + ::= { upsDiagSwitchGear 5 } + +upsDiagSwitchGearBreakerTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of switchgear breakers attached to the UPS." + ::= { upsDiagSwitchGear 6 } + +upsDiagSwitchGearBreakerTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagSwitchGearBreakerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Switchgear breaker table." + ::= { upsDiagSwitchGear 7 } + + upsDiagSwitchGearBreakerEntry OBJECT-TYPE + SYNTAX UpsDiagSwitchGearBreakerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of switchgear breakers." + INDEX { switchgearBreakerIndex } + ::= { upsDiagSwitchGearBreakerTable 1 } + + UpsDiagSwitchGearBreakerEntry ::= + SEQUENCE { + switchgearBreakerIndex + INTEGER, + switchgearBreakerPresent + INTEGER, + switchgearBreakerName + DisplayString, + switchgearBreakerType + INTEGER, + switchgearBreakerStatus + INTEGER + } + + switchgearBreakerIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the switchgear breaker." + ::= { upsDiagSwitchGearBreakerEntry 1 } + + switchgearBreakerPresent OBJECT-TYPE + SYNTAX INTEGER { + notPresent(1), + present(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates if the switchgear breaker is present. + notPresent(1) indicates that the breaker is not present. + present(2) indicates that the breaker is present." + ::= { upsDiagSwitchGearBreakerEntry 2 } + + switchgearBreakerName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the switchgear breaker." + ::= { upsDiagSwitchGearBreakerEntry 3 } + + + switchgearBreakerType OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + unitInputBreaker(2), + staticSwitchInputBreaker(3), + maintenanceBypassBreaker(4), + unitOutputBreaker(5), + systemIsolationBreaker(6), + batteryBreaker1(7), + batteryBreaker2(8) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the switchgear breaker types available in the UPS system. + If the UPS is unable to find any attached breakers, this variable + is set to unknown(1)." + ::= { upsDiagSwitchGearBreakerEntry 4 } + + switchgearBreakerStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + opened(2), + closed(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of switchgear breaker. + unknown(1) indicates the breaker status is unknown. + opened (2) indicates the breaker is opened. + closed (3) indicates the breaker is closed." + ::= { upsDiagSwitchGearBreakerEntry 5 } + + + +upsDiagSubFeedBreakerTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of subfeed breakers attached to the UPS." + ::= { upsDiagSwitchGear 8 } + + +upsDiagSubFeedBreakerTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsDiagSubFeedBreakerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Subfeed breaker table." + ::= { upsDiagSwitchGear 9 } + + upsDiagSubFeedBreakerEntry OBJECT-TYPE + SYNTAX UpsDiagSubFeedBreakerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of subfeed breakers." + INDEX { subfeedBreakerIndex } + ::= { upsDiagSubFeedBreakerTable 1 } + + UpsDiagSubFeedBreakerEntry ::= + SEQUENCE { + subfeedBreakerIndex + INTEGER, + subfeedBreakerPresent + INTEGER, + subfeedBreakerRating + INTEGER, + subfeedBreakerUpperAcceptPowerWarning + INTEGER, + subfeedBreakerUpperAcceptPowerCritical + INTEGER, + subfeedBreakerStatus + INTEGER + + } + + subfeedBreakerIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the subfeed breakers." + ::= { upsDiagSubFeedBreakerEntry 1 } + + subfeedBreakerPresent OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + present (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates if the subfeed breaker is present. + notPresent (1) indicates that the breaker is not present. + present (2) indicates that the breaker is present." + ::= { upsDiagSubFeedBreakerEntry 2 } + + subfeedBreakerRating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current rating of the installed subfeed breaker." + ::= { upsDiagSubFeedBreakerEntry 3 } + + subfeedBreakerUpperAcceptPowerWarning OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum acceptable load before warning is issued. + Expressed as percent of the subfeed breaker rating." + ::= { upsDiagSubFeedBreakerEntry 4 } + + + + subfeedBreakerUpperAcceptPowerCritical OBJECT-TYPE + SYNTAX INTEGER (0..125) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum load before a critical alarm occurs. + Expressed as percent of the subfeed breaker rating." + ::= { upsDiagSubFeedBreakerEntry 5 } + + subfeedBreakerStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + opened (3), + closed (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Circuit Breaker. + unknown(1) indicates the circuit breaker status is unknown. + notInstalled(2) indicates the circuit breaker is not installed. + opened(3) indicates the circuit breaker is opened. + closed(4) indicates the circuit breaker is closed." + ::= { upsDiagSubFeedBreakerEntry 6 } + +upsDiagSwitchGearInstallationLoadPct OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual output load expressed as a percentage of the rating of the UPS." + ::= { upsDiagSwitchGear 10 } + + + upsDiagSubFeedPhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF UPSDiagSubFeedPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of subfeed phase table." + ::= { upsDiagSwitchGear 11 } + + upsDiagSubFeedPhaseEntry OBJECT-TYPE + SYNTAX UPSDiagSubFeedPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular phase." + INDEX { upsDiagSubFeedPhaseIndex } + ::= { upsDiagSubFeedPhaseTable 1 } + + UPSDiagSubFeedPhaseEntry ::= SEQUENCE { + upsDiagSubFeedBreakerIndex INTEGER, + upsDiagSubFeedPhaseIndex INTEGER, + upsDiagSubFeedPhaseCurrent INTEGER + + } + + upsDiagSubFeedBreakerIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The subfeed breaker index." + ::= { upsDiagSubFeedPhaseEntry 1 } + + upsDiagSubFeedPhaseIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The subfeed phase index." + ::= { upsDiagSubFeedPhaseEntry 2 } + + upsDiagSubFeedPhaseCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The subfeed phase current in Amps." + ::= { upsDiagSubFeedPhaseEntry 3 } + + + +upsDiagSwitchgearSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the UPS I/O Cabinet." + ::= { upsDiagSwitchGear 12 } + + + + + + +upsDiagMCCBBoxStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + opened (3), + closed (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the MCCB Box (Molded Case Circuit Breaker Box) external device. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + opened(3) indicates the circuit is opened. + closed(4) indicates the circuit is closed." + ::= { upsDiagMCCBBox 1 } + +upsDiagTransformerStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + ok (3), + fail (4), + lostComm (5), + overtemp (6), + opened (7), + closed (8) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the External Transformer. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + ok(3) indicates the device status is OK. + fail(4) indicates the device status has failed. + lostComm(5) indicates the device has lost communication. + overtemp(6) indicates the device has an over temperature condition. + opened(7) indicates the circuit is opened. + closed(8) indicates the circuit is closed." + ::= { upsDiagTransformer 1 } + + + upsDiagFlyWheelStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + present(2), + notPresent(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the status of flywheel connected to UPS. If the UPS + is unable to determine the state of flywheel, this variable is + set to unknown(1)." + ::= { upsDiagFlyWheel 1 } + + + + +-- the upsDiagnosticComBus group + +upsDiagComBusInternalMIMStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + ok (3), + lostComm (4), + rxFailure (5), + txFailure (6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the internal MIM communication bus. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + ok(3) indicates the device status is OK. + lostComm(4) indicates the device has lost communication. + rxFailure(5) indicates the device has a receive failure. + txFailure(6) indicates the device has a transmit failure." + ::= { upsDiagnosticComBus 1 } + +upsDiagComBusInternalRIMStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + ok (3), + lostComm (4), + rxFailure (5), + txFailure (6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the internal RIM communication bus. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + ok(3) indicates the device status is OK. + lostComm(4) indicates the device has lost communication. + rxFailure(5) indicates the device has a receive failure. + txFailure(6) indicates the device has a transmit failure." + ::= { upsDiagnosticComBus 2 } + +upsDiagComBusMIMtoRIMStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + ok (3), + lostComm (4), + rxFailure (5), + txFailure (6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the MIM to RIM communication bus. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + ok(3) indicates the device status is OK. + lostComm(4) indicates the device has lost communication. + rxFailure(5) indicates the device has a receive failure. + txFailure(6) indicates the device has a transmit failure." + ::= { upsDiagnosticComBus 3 } + +upsDiagComBusExternalMIMStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + ok (3), + lostComm (4), + rxFailure (5), + txFailure (6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the external MIM communication bus. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + ok(3) indicates the device status is OK. + lostComm(4) indicates the device has lost communication. + rxFailure(5) indicates the device has a receive failure. + txFailure(6) indicates the device has a transmit failure." + ::= { upsDiagnosticComBus 4 } + +upsDiagComBusExternalRIMStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + ok (3), + lostComm (4), + rxFailure (5), + txFailure (6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the external RIM communication bus. + unknown(1) indicates the device status is unknown. + notInstalled(2) indicates the device is not installed. + ok(3) indicates the device status is OK. + lostComm(4) indicates the device has lost communication. + rxFailure(5) indicates the device has a receive failure. + txFailure(6) indicates the device has a transmit failure." + ::= { upsDiagnosticComBus 5 } + +-- the upsParallelSystem group + +upsParallelSysLocalAddress OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Defines the UPS ID number in the parallel system." + ::= { upsParallelSystem 1 } + +upsParallelSysRemoteAddress OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Defines the total number of UPSs in parallel." + ::= { upsParallelSystem 2 } + +upsParallelSysRedundancy OBJECT-TYPE + SYNTAX INTEGER { + nplus0 (1), + nplus1 (2), + nplus2 (3), + nplus3 (4), + nplus4 (5), + nplus5 (6) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The redundancy warning level for paralleled UPS + nplus0 (1) indicates that there are no redundant units. + nplus1 (2) indicates that there is one redundant unit. + nplus2 (3) indicates that there are two redundant units. + nplus3 (4) indicates that there are three redundant units. + nplus4 (5) indicates that there are four redundant unit. + nplus5 (6) indicates that there are five redundant units." + ::= { upsParallelSystem 3 } + + +upsParallelInputMaximumCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Maximum input RMS current of the parallel system + measured in Amperes." + ::= { upsParallelSystem 4 } + +upsParallelTotalOutputPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Total Ouptut power of UPS in KW + when UPS are configured in parallel + or -1 if it's unsupported by this UPS." + ::= { upsParallelSystem 5 } + +upsParallelTotalOutputApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Total Ouptut Apparent power of UPS in kVA + when UPS are configured in parallel + or -1 if it's unsupported by this UPS." + ::= { upsParallelSystem 6 } + +-- Parallel Input Phase Table + + upsParallelInputPhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsParallelInputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of input table entries." + ::= { upsParallelSystem 7 } + + upsParallelInputPhaseEntry OBJECT-TYPE + SYNTAX UpsParallelInputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular input phase." + INDEX { upsParallelInputPhaseTableIndex, upsParallelInputPhaseIndex } + ::= { upsParallelInputPhaseTable 1 } + + UpsParallelInputPhaseEntry ::= SEQUENCE { + upsParallelInputPhaseTableIndex INTEGER, + upsParallelInputPhaseIndex INTEGER, + upsParallelInputCurrent INTEGER, + upsParallelInputActivePower INTEGER, + upsParallelInputApparentPower INTEGER, + upsParallelInputVoltage INTEGER, + upsParallelInputMaxVoltage INTEGER, + upsParallelInputMaxCurrent INTEGER, + upsParallelInputTotalActivePower INTEGER, + upsParallelInputTotalApparentPower INTEGER + } + + upsParallelInputPhaseTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The parallel unit identifier." + ::= { upsParallelInputPhaseEntry 1 } + + upsParallelInputPhaseIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input phase identifier." + ::= { upsParallelInputPhaseEntry 2 } + + + upsParallelInputCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input current in amperes, or -1 if it's + unsupported by this UPS." + ::= { upsParallelInputPhaseEntry 3 } + + upsParallelInputActivePower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input power in kW, or -1 if it's + unsupported by this UPS." + ::= { upsParallelInputPhaseEntry 4 } + + upsParallelInputApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input apparent power in kVA, or -1 if it's + unsupported by this UPS." + ::= { upsParallelInputPhaseEntry 5 } + + upsParallelInputVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input voltage of UPS in volts, or -1 if it's + unsupported by this UPS." + ::= { upsParallelInputPhaseEntry 6 } + + upsParallelInputMaxVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The peak input voltage in VAC measured since the last reset, + or -1 if it's unsupported by this UPS." + ::= { upsParallelInputPhaseEntry 7 } + + upsParallelInputMaxCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The peak input current in amperes measured since last reset, + or -1 if it's unsupported by this UPS." + ::= { upsParallelInputPhaseEntry 8 } + + upsParallelInputTotalActivePower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Total active input power of the parallel system in kW." + ::= { upsParallelInputPhaseEntry 9 } + + upsParallelInputTotalApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Total apparent input power of the parallel system in kVA." + ::= { upsParallelInputPhaseEntry 10 } + + +-- Parallel Output Phase Table + + upsParallelOutputPhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsParallelOutputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of output table entries. The number of + entries is given by the sum of the upsPhaseNumOutputPhases." + ::= { upsParallelSystem 8 } + + upsParallelOutputPhaseEntry OBJECT-TYPE + SYNTAX UpsParallelOutputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular output phase." + INDEX { upsParallelOutputPhaseTableIndex, upsParallelOutputPhaseIndex } + ::= { upsParallelOutputPhaseTable 1 } + + UpsParallelOutputPhaseEntry ::= SEQUENCE { + upsParallelOutputPhaseTableIndex INTEGER, + upsParallelOutputPhaseIndex INTEGER, + upsParallelOutputCurrent INTEGER, + upsParallelOutputLoad INTEGER, + upsParallelOutputPercentLoad INTEGER, + upsParallelOutputPower INTEGER + } + + upsParallelOutputPhaseTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output identifier." + ::= { upsParallelOutputPhaseEntry 1 } + + upsParallelOutputPhaseIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output phase identifier." + ::= { upsParallelOutputPhaseEntry 2 } + + upsParallelOutputCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output current in amperes drawn + by the load on the UPS, or -1 if it's unsupported + by this UPS." + ::= { upsParallelOutputPhaseEntry 3 } + + upsParallelOutputLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output load in VA, or -1 if it's unsupported + by this UPS." + ::= { upsParallelOutputPhaseEntry 4 } + + upsParallelOutputPercentLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The percentage of the UPS load capacity in VA at + present redundancy being used on this output phase, + or -1 if it's unsupported by this UPS." + ::= { upsParallelOutputPhaseEntry 5 } + + upsParallelOutputPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output power in Watts, or -1 if it's + unsupported by this UPS." + ::= { upsParallelOutputPhaseEntry 6 } + + -- Parallel Output Apparent Power Table + + upsParallelOutputApparentPowerTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsParallelOutputApparentPowerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of output table entries. The number of entries + is given by the value of upsOutputNumPhases." + ::= { upsParallelSystem 9 } + + upsParallelOutputApparentPowerEntry OBJECT-TYPE + SYNTAX UpsParallelOutputApparentPowerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular output." + INDEX { upsParallelOutputApparentPowerTableIndex } + ::= { upsParallelOutputApparentPowerTable 1 } + + UpsParallelOutputApparentPowerEntry ::= SEQUENCE { + upsParallelOutputApparentPowerTableIndex INTEGER, + upsParallelOutputApparentPower INTEGER + } + + upsParallelOutputApparentPowerTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The UPS parallel output identifier." + ::= { upsParallelOutputApparentPowerEntry 1 } + + upsParallelOutputApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The apparent power of each of UPS in kVA + when UPS are configured in parallel." + ::= { upsParallelOutputApparentPowerEntry 2 } + + +upsParallelDiagSubSysBreakerTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsParallelDiagSubSysBreakerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for diagnostics of parallel Circuit Breakers." + ::= { upsParallelSystem 10 } + +upsParallelDiagSubSysBreakerEntry OBJECT-TYPE + SYNTAX UpsParallelDiagSubSysBreakerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The diagnostics of Circuit Breaker." + INDEX { upsParallelDiagSubSysBreakerFrameIndex, upsParallelDiagSubSysBreakerIndex} + ::= { upsParallelDiagSubSysBreakerTable 1 } + +UpsParallelDiagSubSysBreakerEntry ::= + SEQUENCE { + upsParallelDiagSubSysBreakerFrameIndex INTEGER, + upsParallelDiagSubSysBreakerIndex INTEGER, + upsParallelDiagSubSysBreakerStatus INTEGER, + upsParallelDiagSubSysBreakerName DisplayString + } + +upsParallelDiagSubSysBreakerFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Parallel UPS index entry." + ::= { upsParallelDiagSubSysBreakerEntry 1 } + +upsParallelDiagSubSysBreakerIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the Circuit Breaker." + ::= { upsParallelDiagSubSysBreakerEntry 2 } + +upsParallelDiagSubSysBreakerStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + notInstalled (2), + opened (3), + closed (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Circuit Breaker. + unknown(1) indicates the circuit breaker status is unknown. + notInstalled(2) indicates the circuit breaker is not installed. + opened(3) indicates the circuit breaker is opened. + closed(4) indicates the circuit breaker is closed." + ::= { upsParallelDiagSubSysBreakerEntry 3 } + +upsParallelDiagSubSysBreakerName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of Circuit Breaker." + ::= { upsParallelDiagSubSysBreakerEntry 4 } + +upsParallelOutputTotalPercentLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + +DESCRIPTION + "The percentage of the UPS total load capacity in kVA + or -1 if it's unsupported by this UPS." + ::= { upsParallelSystem 11 } +-- Parallel Output Active Power Table + +upsParallelOutputActivePowerTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsParallelOutputActivePowerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of output table entries. The number of entries + is given by the value of upsParallelSysRemoteAddress." + ::= { upsParallelSystem 12 } + +upsParallelOutputActivePowerEntry OBJECT-TYPE + SYNTAX UpsParallelOutputActivePowerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular output." + INDEX { upsParallelOutputActivePowerTableIndex } + ::= { upsParallelOutputActivePowerTable 1 } + +UpsParallelOutputActivePowerEntry ::= SEQUENCE { + upsParallelOutputActivePowerTableIndex INTEGER, + upsParallelOutputActivePower INTEGER + } + +upsParallelOutputActivePowerTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The UPS parallel output identifier." + ::= { upsParallelOutputActivePowerEntry 1 } + +upsParallelOutputActivePower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The active power of each UPS in kW + when UPSs are configured in parallel." + ::= { upsParallelOutputActivePowerEntry 2 } + +upsParallelSysSwitchGearInstallationLoadPct OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual output load expressed as a percentage of the rating of the + Parallel UPS system." + ::= { upsParallelSystem 13 } + + + +upsParallelSysRedundancyStatus OBJECT-TYPE + SYNTAX INTEGER { + nplus0 (1), + nplus1 (2), + nplus2 (3), + nplus3 (4), + nplus4 (5), + nplus5 (6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Displays the number of backup or redundant UPSs set up on the parallel system. + nplus0 (1) no redundant units. + nplus1 (2) one redundant unit. + nplus2 (3) two redundant units. + nplus3 (4) three redundant units. + nplus4 (5) four redundant units. + nplus5 (6) five redundant units." + ::= { upsParallelSystem 14 } + +upsParallelSysName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "An ID string for the group of UPS units in the same parallel system. + Some products do not allow write operations for this OID." + ::= { upsParallelSystem 15 } + + + + +-- the upsPhysicalLayout group +upsIOFrameLayoutPositionID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Defines the position ID of UPS frame." + ::= { upsPhysicalLayout 1 } + +upsBottomFeedFrameLayoutPositionID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Defines the position ID of bottom feed frame." + ::= { upsPhysicalLayout 2 } + +upsSwitchGearLayoutPositionID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Defines the position ID of switchgear." + ::= { upsPhysicalLayout 3 } + +-- the upsBatteryFrameLayoutTable subgroup +upsBatteryFrameLayoutTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of battery frames." + ::= { upsPhysicalLayout 4 } + +upsBatteryFrameLayoutTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsBatteryFrameLayoutEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Battery frame layout position ID table." + ::= { upsPhysicalLayout 5 } + + upsBatteryFrameLayoutEntry OBJECT-TYPE + SYNTAX UpsBatteryFrameLayoutEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of layout position IDs of battery frames." + INDEX { batteryFrameIndex } + ::= { upsBatteryFrameLayoutTable 1 } + + UpsBatteryFrameLayoutEntry ::= + SEQUENCE { + batteryFrameIndex + INTEGER, + batteryFramePositionID + INTEGER + } + + batteryFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the battery frame." + ::= { upsBatteryFrameLayoutEntry 1 } + + batteryFramePositionID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Defines the position ID of each of the battery frames in the row." + ::= { upsBatteryFrameLayoutEntry 2 } + +-- the upsSideCarFrameLayoutTable subgroup +upsSideCarFrameLayoutTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of sidecar frames." + ::= { upsPhysicalLayout 6 } + +upsSideCarFrameLayoutTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsSideCarFrameLayoutEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Sidecar frame layout position ID table." + ::= { upsPhysicalLayout 7 } + + upsSideCarFrameLayoutEntry OBJECT-TYPE + SYNTAX UpsSideCarFrameLayoutEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of sidecar frame layout position IDs." + INDEX { sideCarFrameIndex } + ::= { upsSideCarFrameLayoutTable 1 } + + UpsSideCarFrameLayoutEntry ::= + SEQUENCE { + sideCarFrameIndex + INTEGER, + sideCarFramePositionID + INTEGER + } + + sideCarFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the sidecar frame." + ::= { upsSideCarFrameLayoutEntry 1 } + + sideCarFramePositionID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Defines the position ID of each of the sidecar frames in the row." + ::= { upsSideCarFrameLayoutEntry 2 } + +-- the upsPowerFrameLayoutTable subgroup +upsPowerFrameLayoutTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of power frames." + ::= { upsPhysicalLayout 8 } + +upsPowerFrameLayoutTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsPowerFrameLayoutEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Power frame layout position ID table." + ::= { upsPhysicalLayout 9 } + + upsPowerFrameLayoutEntry OBJECT-TYPE + SYNTAX UpsPowerFrameLayoutEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of power frame layout position IDs." + INDEX { powerFrameIndex } + ::= { upsPowerFrameLayoutTable 1 } + + UpsPowerFrameLayoutEntry ::= + SEQUENCE { + powerFrameIndex + INTEGER, + powerFramePositionID + INTEGER + } + + powerFrameIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the power frame." + ::= { upsPowerFrameLayoutEntry 1 } + + powerFramePositionID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Defines the position ID of each of the power frames in the row." + ::= { upsPowerFrameLayoutEntry 2 } + +-- the upsIntegratedATS group + +upsIntegratedATSSelectedSource OBJECT-TYPE + SYNTAX INTEGER { + noSourceSelected (1), + unknown (2), + sourceA (3), + sourceB (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The source which is currently selected by the ATS to supply the UPS." + ::= { upsIntegratedATS 1 } + + +upsIntegratedATSPreferredSource OBJECT-TYPE + SYNTAX INTEGER { + upsIntegratedATSNoSourcePreference (1), + upsIntegratedATSPreferSourceA (2), + upsIntegratedATSPreferSourceB (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The preferred source of power when both sources are OK." + ::= { upsIntegratedATS 2 } + +upsIntegratedATSUpsReturnStaggering OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This is a delay factor applied to the retransfer of this UPS with integrated ATS. + When multiple UPSs are in use from a single source, each UPS can have a unique delay value, + which will reduce inrush by preventing all UPSs from transferring at the same time." + ::= { upsIntegratedATS 3 } + +upsIntegratedATSSourceTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of input sources for this integrated ATS." + ::= { upsIntegratedATS 4 } + +upsIntegratedATSSourceTable OBJECT-TYPE + SYNTAX SEQUENCE OF UpsIntegratedATSSourceEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting status and settings for the ATS input sources. + The number of entries is contained in the upsIntegratedATSSourceTableSize OID." + ::= { upsIntegratedATS 5 } + +upsIntegratedATSSourceEntry OBJECT-TYPE + SYNTAX UpsIntegratedATSSourceEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The input source status to get." + INDEX { upsIntegratedATSSourceIndex} + ::= { upsIntegratedATSSourceTable 1 } + +UpsIntegratedATSSourceEntry ::= + SEQUENCE { + upsIntegratedATSSourceIndex INTEGER, + upsIntegratedATSSourceName DisplayString, + upsIntegratedATSSourceStatus INTEGER, + upsIntegratedATSLineFailDelay INTEGER, + upsIntegratedATSLineStabilityDelay INTEGER + } + +upsIntegratedATSSourceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the input source entry." + ::= { upsIntegratedATSSourceEntry 1 } + +upsIntegratedATSSourceName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the input source. This OID is provided + for informational purposes only." + ::= { upsIntegratedATSSourceEntry 2 } + +upsIntegratedATSSourceStatus OBJECT-TYPE + SYNTAX INTEGER { + upsIntegratedATSSourceGood (1), + upsIntegratedATSSourceBad (2), + upsIntegratedATSSourceUnknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the input source status." + ::= { upsIntegratedATSSourceEntry 3 } + +upsIntegratedATSLineFailDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The delay between a selected input source becoming bad, and the ATS switching away from that source. + This delay is used to make sure that the line has truly failed before the ATS will be switched. + Specified in seconds." + ::= { upsIntegratedATSSourceEntry 4 } + +upsIntegratedATSLineStabilityDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The delay between an unselected input source becoming good, and the ATS switching to that source. + This delay is used to make sure that the line has truly returned before the ATS will be switched. + Specified in seconds." + ::= { upsIntegratedATSSourceEntry 5 } + +-- the serialPort2Config group + +serialPort2Mode OBJECT-TYPE + SYNTAX INTEGER { + localConsole(1), + passthrough(2) + } + ACCESS read-write + STATUS obsolete + DESCRIPTION + "Setting this variable to passthrough will enable mini's port2 + behave like a UPS port. Choosing localConsole will enable the port + to be used as local console." + ::= { serialPort2Config 1 } +-- the serialPort2Control group + +setPulseOnTXD OBJECT-TYPE + SYNTAX INTEGER { + noSetPulseOnTXD(1), + setPulseOnTXD(2), + setTXDLow(3), + setTXDHigh(4) + + } + ACCESS read-write + STATUS obsolete + DESCRIPTION + "Setting this variable to setPulseOnTXD(2) + causes adapter to generate a PULSE on TXD pin of serial port 2. + The duration in the prototype implementation will be 1 second. + + Setting this value to noSetPulseOnTXD(1) has no + effect. + + The value noSetPulseOnTXD(1) will always be returned + when the variable is read. + + Setting this value to setTXDLow(3), or setTXDHigh(4) will keep TXD + always low or high respectively." + ::= { serialPort2Control 1 } + +-- the sPDUIdent group + +sPDUIdentHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the PDU. This value + is set at the factory." + ::= { sPDUIdent 1 } + +sPDUIdentFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An 8 byte ID string identifying the PDU firmware revision. + This value is set at the factory." + ::= { sPDUIdent 2 } + + +sPDUIdentDateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date when the PDU was manufactured in mm/dd/yy format. + This value is set at the factory. The year 2000 will be + represented by 00." + ::= { sPDUIdent 3 } + +sPDUIdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A 10-character string identifying the model number of + the PDU internal. This value is set at the factory." + ::= { sPDUIdent 4 } + +sPDUIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A 12-character string identifying the serial number of + the PDU internal microprocessor. This value is set at + the factory." + ::= { sPDUIdent 5 } + + +-- the sPDUMasterControl group + +sPDUMasterControlSwitch OBJECT-TYPE + SYNTAX INTEGER { + turnAllOnNow (1), + turnAllOnSequence (2), + turnAllOffNow (3), + rebootAllNow (4), + rebootAllSequence (5), + noCommand (6), + turnAllOffSequence (7) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to turnAllOnNow (1) will turn all outlets + on immediately. + + Setting this OID to turnAllOnSequence (2) will turn all outlets + on as defined by each outlet's sPDUOutletPowerOnTime OID value. + + Setting this OID to turnAllOff (3) will turn all outlets + off immediately. + + Setting this OID to rebootAllNow (4) will reboot all outlets + immediately. + + For MasterSwitch firmware version 1.X, setting this OID to + rebootAllSequence (5) reboots all outlets, with power returned + to the outlets in the sequence defined by each outlet's + sPDUOutletPowerOnTime OID value. + + For MasterSwitch firmware version 2.X, setting this OID to + rebootAllSequence (5) will cause a turnAllOffSequence to be performed. + Once all outlets are off, the MasterSwitch will then delay the + sPDUMasterConfigReboot OID time, and then perform a turnAllOnSequence. + + For MasterSwitch firmware version 2.X, setting this OID to + turnAllOffSequence (7) will turn all outlets off as defined by + each outlet's sPDUOutletPowerOffTime OID value. + + For MasterSwitch firmware version 1.X, setting this OID to + turnAllOffSequence (7) will have no effect. + + Getting this OID will return the noCommand (6) value." + + ::= { sPDUMasterControl 1 } + + +sPDUMasterState OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will cause the status of all outlets to be + returned. This OID is provided for informational purposes only. + To change the outlet state, the user should use the sPDUOutletCtl + OID in the sPDUOutletControlTable. + + The format of the data returned is a character string consisting + of the word 'On' if the outlet is on or 'Off' if the outlet is + off. At least one space will delimit each outlet entry in the + string. + + If the outlet states are unknown, the character string 'Unknown' + will be returned. This signifies that there is an inconsistency + in the PDU. In the rare case that this should happen, the user + is advised to shut down all equipment powered by the PDU and + then cycle the PDU's power. This will put the PDU in a consistent + state." + + ::= { sPDUMasterControl 2 } + +sPDUMasterPending OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will cause the command pending status of all outlets to be returned. + + The format of the data returned is a character string consisting + of the word 'Yes' if a command is pending for the outlet or 'No' + if there is no command pending for the outlet. At least one + space will delimit each outlet entry in the string. + + If the pending states are unknown, the character string 'Unknown' + will be returned. This signifies that there is an inconsistency + in the PDU. In the rare case that this should happen, the user + is advised to shut down all equipment powered by the PDU and then + cycle the PDU's power. This will put the PDU in a consistent state." + ::= { sPDUMasterControl 3 } + + +-- the sPDUMasterConfig group + +sPDUMasterConfigPowerOn OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + " The amount of delay, in seconds, between when + power is provided to the PDU and when the PDU + provides basic master power to the outlets. + + Allowed values are: + + -1 never apply power automatically. + 0 apply power immediately. + 15 apply power in 15 seconds. + 30 apply power in 30 seconds. + 45 apply power in 45 seconds. + 60 apply power in 60 seconds (1 minute). + 120 apply power in 120 seconds (2 minutes). + 300 apply power in 300 seconds (5 minutes). + + If a value other than a supported value is provided in a + set request, the PDU interprets it as the next lower + acceptable value. If the provided value is lower than + the lowest acceptable value, the lowest acceptable + value is used." + + ::= { sPDUMasterConfig 1 } + +sPDUMasterConfigReboot OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "During a reboot sequence, power is turned off and then + back on. This OID defines the amount of time to wait, + in seconds, after turning the power off, at the start + of the sequence, before turning power back on, at the + end of the reboot sequence. + + Allowed values are: + + 5 wait 5 seconds between off/on. + 10 wait 10 seconds between off/on. + 15 wait 15 seconds between off/on. + 20 wait 20 seconds between off/on. + 30 wait 30 seconds between off/on. + 45 wait 45 seconds between off/on. + 60 wait 60 seconds (1 minute) between off/on. + + If a value other than a supported value is provided in a + set request, the PDU interprets it as the next lower + acceptable value. If the provided value is lower than + the lowest acceptable value, the lowest acceptable + value is used. + + This OID is read-only for the MasterSwitch version 2.X and is the + maximum sPDUOutletRebootDuration OID of the individual outlets." + + ::= { sPDUMasterConfig 2 } + +sPDUMasterConfigPDUName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the PDU." + ::= { sPDUMasterConfig 3 } + + + +-- the sPDUOutletControl group +sPDUOutletControlTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of outlets for the PDU." + ::= { sPDUOutletControl 1 } + + +sPDUOutletControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUOutletControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for control of individual outlet switches. The number of + entries is contained in the sPDUOutletControlTableSize OID." + ::= { sPDUOutletControl 2 } + +sPDUOutletControlEntry OBJECT-TYPE + SYNTAX SPDUOutletControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlets to control." + INDEX { sPDUOutletControlIndex} + ::= { sPDUOutletControlTable 1 } + +SPDUOutletControlEntry ::= + SEQUENCE { + sPDUOutletControlIndex INTEGER, + sPDUOutletPending INTEGER, + sPDUOutletCtl INTEGER, + sPDUOutletCtlName DisplayString + } + +sPDUOutletControlIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { sPDUOutletControlEntry 1 } + +sPDUOutletPending OBJECT-TYPE + SYNTAX INTEGER{ + commandPending (1), + noCommandPending (2), + commandPendingUnknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Reports whether the current outlet has a pending command. + + If the commandPendingUnknown (3) value is returned, all + devices powered by the PDU should be shut down. The PDU's + power should then be cycled to clear this condition." + + ::= { sPDUOutletControlEntry 2 } + +sPDUOutletCtl OBJECT-TYPE + SYNTAX INTEGER { + outletOn (1), + outletOff (2), + outletReboot (3), + outletUnknown (4), + outletOnWithDelay (5), + outletOffWithDelay (6), + outletRebootWithDelay (7) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this variable will return the outlet state. If + the outlet is on, the outletOn (1) value will be returned. + If the outlet is off, the outletOff (2) value will be + returned. + + If the state of the outlet cannot be determined, the + outletUnknown (4) value will be returned. If the + outletUnknown condition should occur, all devices + powered by the PDU should be shut down. The PDU's power + should then be cycled to clear this condition. + + Setting this variable to outletOn (1) will turn the outlet on. + + Setting this variable to outletOff (2) will turn the outlet off. + + Setting this variable to outletReboot (3) will reboot the outlet. + + Setting this variable to outletOnWithDelay (5) will turn the outlet on + after the sPDUOutletPowerOnTime OID has elapsed. This option is not + valid for MasterSwitch firmware version 1.X. + + Setting this variable to outletOffWithDelay (6) will turn the outlet off + after the sPDUOutletPowerOffTime OID has elapsed. This option is not valid + for MasterSwitch firmware version 1.X. + + Setting this variable to outletRebootWithDelay (7) will turn the outlet off + after the sPDUOutletPowerOffTime OID has elapsed, wait the sPDUOutletRebootDuration + OID time, then turn the outlet back on. + This option is not valid for MasterSwitch firmware version 1.X." + + ::= { sPDUOutletControlEntry 3 } + +sPDUOutletCtlName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the outlet. Maximum size is 20 characters. + This OID is provided for informational purposes only. + This value is set by the sPDUOutletName OID." + + ::= { sPDUOutletControlEntry 4 } + +-- the sPDUOutletConfig group +sPDUOutletConfigTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of outlets for the PDU." + ::= { sPDUOutletConfig 1 } + +sPDUOutletConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUOutletConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The list of outlets to configure. The number of + entries is defined by the sPDUOutletConfigTableSize + OID." + + ::= { sPDUOutletConfig 2 } + +sPDUOutletConfigEntry OBJECT-TYPE + SYNTAX SPDUOutletConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlets to control." + INDEX { sPDUOutletConfigIndex} + ::= { sPDUOutletConfigTable 1 } + +SPDUOutletConfigEntry ::= + SEQUENCE { + sPDUOutletConfigIndex INTEGER, + sPDUOutletPowerOnTime INTEGER, + sPDUOutletName DisplayString, + sPDUOutletPowerOffTime INTEGER, + sPDUOutletRebootDuration INTEGER + } + +sPDUOutletConfigIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { sPDUOutletConfigEntry 1 } + +sPDUOutletPowerOnTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of time (in seconds) the outlet will delay + powering on when the MasterSwitch is powered on. + + Allowed values are: + + -1 never power on automatically. + 0 power on with the Master Switch. + 15 power on 15 seconds after the MasterSwitch has power applied. + 30 power on 30 seconds after the MasterSwitch has power applied. + 45 power on 45 seconds after the MasterSwitch has power applied. + 60 power on 60 seconds (1 minute) after the MasterSwitch has power applied. + 120 power on 120 seconds (2 minutes) after the MasterSwitch has power applied. + 300 power on 300 seconds (5 minutes) after the MasterSwitch has power applied. + + If a value other than a supported value is provided in a + set request, the PDU interprets it as the next lower + acceptable value. If the provided value is lower than + the lowest acceptable value, the lowest acceptable + value is used." + + ::= { sPDUOutletConfigEntry 2 } + +sPDUOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the outlet. Maximum size is 20 characters." + + ::= { sPDUOutletConfigEntry 3 } + +sPDUOutletPowerOffTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of time (in seconds) the outlet will delay + powering off. + + Allowed values are: + + -1 never power off automatically. + 0 power off with the MasterSwitch. + 15 power off 15 seconds after being commanded. + 30 power off 30 seconds after being commanded. + 45 power off 45 seconds after being commanded. + 60 power off 60 seconds (1 minute) after being commanded. + 120 power off 120 seconds (2 minutes) after being commanded. + 300 power off 300 seconds (5 minutes) after being commanded. + + If a value other than a supported value is provided in a + set request, the PDU interprets it as the next lower + acceptable value. If the provided value is lower than + the lowest acceptable value, the lowest acceptable + value is used. + + This OID is not available for MasterSwitch firmware version 1.X." + + ::= { sPDUOutletConfigEntry 4 } + +sPDUOutletRebootDuration OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "During a reboot sequence, power is turned off and then + back on. This OID defines the amount of time to wait, + in seconds, after turning the power off, at the start + of the sequence, before turning power back on, at the + end of the reboot sequence. + + Allowed values are: + + 5 wait 5 seconds between off/on. + 10 wait 10 seconds between off/on. + 15 wait 15 seconds between off/on. + 20 wait 20 seconds between off/on. + 30 wait 30 seconds between off/on. + 45 wait 45 seconds between off/on. + 60 wait 60 seconds (1 minute) between off/on. + + If a value other than a supported value is provided in a + set request, the PDU interprets it as the next lower + acceptable value. If the provided value is lower than + the lowest acceptable value, the lowest acceptable + value is used. + + This OID is not available for MasterSwitch firmware version 1.X." + + ::= { sPDUOutletConfigEntry 5 } + + +-- the sPDUIdentVM group + +sPDUIdentVMTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of MasterSwitch VMs controllable + by this IP address." + ::= { sPDUIdentVM 1 } + + +sPDUIdentVMTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUIdentVMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for query of the individual MasterSwitch VMs. + The number of entries is contained in the + sPDUIdentVMTableSize OID." + ::= { sPDUIdentVM 2 } + +sPDUIdentVMEntry OBJECT-TYPE + SYNTAX SPDUIdentVMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The MasterSwitch VMs to query." + INDEX { sPDUIdentVMIndex} + ::= { sPDUIdentVMTable 1 } + +SPDUIdentVMEntry ::= + SEQUENCE { + sPDUIdentVMIndex INTEGER, + sPDUIdentNameVM DisplayString, + sPDUIdentHardwareRevVM DisplayString, + sPDUIdentFirmwareRevVM DisplayString, + sPDUIdentDateOfManufactureVM DisplayString, + sPDUIdentModelNumberVM DisplayString, + sPDUIdentSerialNumberVM DisplayString + } + +sPDUIdentVMIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch VM entry." + ::= { sPDUIdentVMEntry 1 } + +sPDUIdentNameVM OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A 23-character string identifying the + MasterSwitch VM. " + ::= { sPDUIdentVMEntry 2 } + +sPDUIdentHardwareRevVM OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware version of the MasterSwitch VM. + This value is set at the factory." + ::= { sPDUIdentVMEntry 3 } + +sPDUIdentFirmwareRevVM OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An 6-character ID string identifying the MasterSwitch VM + firmware version. This value is set at the factory." + ::= { sPDUIdentVMEntry 4 } + + +sPDUIdentDateOfManufactureVM OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date when the MasterSwitch VM was manufactured in mm/dd/yyyy format. + This value is set at the factory. " + ::= { sPDUIdentVMEntry 5 } + +sPDUIdentModelNumberVM OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A 17-character string identifying the model number of + the MasterSwitch VM. This value is set at the factory." + ::= { sPDUIdentVMEntry 6 } + +sPDUIdentSerialNumberVM OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A 17-character string identifying the serial number of + the MasterSwitch VM. This value is set at the factory." + ::= { sPDUIdentVMEntry 7 } + + +-- the sPDUMasterControlVM group + +sPDUMasterControlVMTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of MasterSwitch VMs controllable + by this IP address." + ::= { sPDUMasterControlVM 1 } + + +sPDUMasterControlVMTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUMasterControlVMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for control of the individual MasterSwitch VMs. + The number of entries is contained in the + sPDUMasterControlVMTableSize OID." + ::= { sPDUMasterControlVM 2 } + +sPDUMasterControlVMEntry OBJECT-TYPE + SYNTAX SPDUMasterControlVMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The MasterSwitch VMs to control." + INDEX { sPDUMasterControlVMIndex} + ::= { sPDUMasterControlVMTable 1 } + +SPDUMasterControlVMEntry ::= + SEQUENCE { + sPDUMasterControlVMIndex INTEGER, + sPDUMasterControlVMName DisplayString, + sPDUMasterControlVMCommand INTEGER + } + +sPDUMasterControlVMIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch VM entry." + ::= { sPDUMasterControlVMEntry 1 } + +sPDUMasterControlVMName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch VM. The maximum + value is 23 characters. The name is set by + using the sPDUMasterConfigVMName OID." + ::= { sPDUMasterControlVMEntry 2 } + +sPDUMasterControlVMCommand OBJECT-TYPE + SYNTAX INTEGER { + noCommandAllVM (1), + immediateAllOnVM (2), + immediateAllOffVM (3), + immediateAllRebootVM (4), + delayedAllOnVM (5), + delayedAllOffVM (6), + sequencedAllRebootVM (7), + delayedAllRebootVM (8), + delayedSequenceAllRebootVM (9), + cancelAllPendingCommandsVM (10), + audioAlarmMute (11) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to immediateAllOnVM (2) will turn all outlets + on immediately. + + Setting this OID to immediateAllOffVM (3) will turn all outlets + off immediately. + + Setting this OID to immediateAllRebootVM (4) will reboot all outlets + immediately. + + Setting this OID to delayedAllOnVM (5) will turn all outlets on as + defined by each outlet's sPDUOutletConfigVMPowerOnTime OID value. + + Setting this OID to delayedAllOffVM (6) will turn all outlets + off as defined by each outlet's sPDUOutletConfigVMPowerOffTime OID value. + + Setting this OID to sequencedAllRebootVM (7) will cause a + immediateAllOffVM command to be performed. The MasterSwitch VM will + then delay the sPDUMasterStatusVMRebootDuration OID time, and then + perform a delayedAllOnVM command. + + Setting this OID to delayedAllRebootVM (8) will cause a delayedAllOffVM + command to be performed. Each outlet will then wait its + sPDUOutletConfigVMRebootDuration before returning power to the outlet. + + Setting this OID to delayedSequenceAllRebootVM (9) will cause a + delayedAllOffVM command to be performed. Once all outlets are off, + the MasterSwitch VM will then delay the sPDUMasterStatusVMRebootDuration + OID time, and then perform a delayedAllOnVM command. + + Setting this OID to cancelAllPendingCommandsVM (10) will cause all pending + commands on the MasterSwitch VM to be canceled. + + + Setting this OID to audioAlarmMute (11) will temporarily silence the audible + alarm for the duration of the current overload condition. The audible alarm + will be activated on subsequent overload alarms. + + Getting this OID will return the noCommandAllVM (1) value." + ::= { sPDUMasterControlVMEntry 3 } + + +-- the sPDUMasterConfigVM group + +sPDUMasterConfigVMTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of MasterSwitch VMs configurable + by this IP address." + ::= { sPDUMasterConfigVM 1 } + + +sPDUMasterConfigVMTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUMasterConfigVMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of the individual MasterSwitch VMs. + The number of entries is contained in the + sPDUMasterConfigVMTableSize OID." + ::= { sPDUMasterConfigVM 2 } + +sPDUMasterConfigVMEntry OBJECT-TYPE + SYNTAX SPDUMasterConfigVMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The MasterSwitch VMs to configure." + INDEX { sPDUMasterConfigVMIndex} + ::= { sPDUMasterConfigVMTable 1 } + +SPDUMasterConfigVMEntry ::= + SEQUENCE { + sPDUMasterConfigVMIndex INTEGER, + sPDUMasterConfigVMName DisplayString, + sPDUMasterConfigVMColdstartDelay INTEGER, + sPDUMasterConfigVMAudioAlarmActivated INTEGER, + sPDUMasterConfigVMHighLoadWarningThreshold INTEGER, + sPDUMasterConfigVMLowLoadWarningThreshold INTEGER, + sPDUMasterConfigVMOverloadRestriction INTEGER + } + +sPDUMasterConfigVMIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch VM entry." + ::= { sPDUMasterConfigVMEntry 1 } + + +sPDUMasterConfigVMName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch VM. Maximum size is 23 characters." + ::= { sPDUMasterConfigVMEntry 2 } + +sPDUMasterConfigVMColdstartDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + " The amount of delay, in seconds, between when + power is provided to the MasterSwitch VM and + when the MasterSwitch VM provides basic master + power to the outlets. + + Allowed values are: + + -1 never apply power automatically. + 0 apply power immediately. + 15 apply power in 15 seconds. + 30 apply power in 30 seconds. + 45 apply power in 45 seconds. + 60 apply power in 60 seconds (1 minute). + 120 apply power in 120 seconds (2 minutes). + 300 apply power in 300 seconds (5 minutes). + + If a value other than a supported value is provided in a + set request, the MasterSwitch VM interprets it as the next lower + acceptable value. If the provided value is lower than + the lowest acceptable value, the lowest acceptable + value is used." + ::= { sPDUMasterConfigVMEntry 3 } + +sPDUMasterConfigVMAudioAlarmActivated OBJECT-TYPE + SYNTAX INTEGER { + audioAlarmActiveNever (1), + audioAlarmActiveOnOverload (2), + audioAlarmActiveOnOverloadImminent (3) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to audioAlarmActiveNever (1) will disable + the audio alarm on the MasterSwitch VM. + + Setting this OID to audioAlarmActiveOnOverload (2) will + activate the audio alarm on the MasterSwitch VM when an + overload condition is present. + + Setting this OID to audioAlarmActiveOnOverloadImminent (3) + will activate the audio alarm on the MasterSwitch VM when + the load on the MasterSwitch VM has surpassed the + sPDUMasterConfigVMHighLoadWarningThreshold OID value." + ::= { sPDUMasterConfigVMEntry 4 } + +sPDUMasterConfigVMHighLoadWarningThreshold OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the power consumption of + the load is nearing an overload condition. It is + represented as a percentage of full load." + ::= { sPDUMasterConfigVMEntry 5 } + +sPDUMasterConfigVMLowLoadWarningThreshold OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the power consumption of + the load is nearing a low consumption condition. It is + represented as a percentage of full load." + ::= { sPDUMasterConfigVMEntry 6 } + +sPDUMasterConfigVMOverloadRestriction OBJECT-TYPE + SYNTAX INTEGER { + alwaysAllowTurnON (1), + restrictOnWarning (2), + restrictOnOverload (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This OID controls the behavior of the MasterSwitch VM + when an overload condition is possible and additional + outlets are requested to be turned on. + + Setting this OID to alwaysAllowTurnON (1) will always allow + the outlets to turn on. + + Setting this OID to restrictOnWarning (2) will not allow + outlets to turn on if the sPDUMasterConfigVMHighLoadWarningThreshold + OID is exceeded. + + Setting this OID to restrictOnOverload (3) will not allow + outlets to turn on if the MasterSwitch Vm is in an + overload condition." + ::= { sPDUMasterConfigVMEntry 7 } + +-- the sPDUMasterStatusVM group + +sPDUMasterStatusVMTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of MasterSwitch VMs at + this IP address." + ::= { sPDUMasterStatusVM 1 } + + +sPDUMasterStatusVMTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUMasterStatusVMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for gathering of status from the individual + MasterSwitch VMs. The number of entries is contained + in the sPDUMasterStatusVMTableSize OID." + ::= { sPDUMasterStatusVM 2 } + +sPDUMasterStatusVMEntry OBJECT-TYPE + SYNTAX SPDUMasterStatusVMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The MasterSwitch VMs to gather status from." + INDEX { sPDUMasterStatusVMIndex} + ::= { sPDUMasterStatusVMTable 1 } + +SPDUMasterStatusVMEntry ::= + SEQUENCE { + sPDUMasterStatusVMIndex INTEGER, + sPDUMasterStatusVMName DisplayString, + sPDUMasterStatusVMCommandPending INTEGER, + sPDUMasterStatusVMOverloadCondition INTEGER, + sPDUMasterStatusVMLowLoadCondition INTEGER, + sPDUMasterStatusVMCurrentLoad INTEGER, + sPDUMasterStatusVMMaxLoad INTEGER, + sPDUMasterStatusVMOutletCount INTEGER, + sPDUMasterStatusVMRebootDuration INTEGER + } + +sPDUMasterStatusVMIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch VM entry." + ::= { sPDUMasterStatusVMEntry 1 } + +sPDUMasterStatusVMName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch VM. Maximum size is 23 characters." + ::= { sPDUMasterStatusVMEntry 2 } + +sPDUMasterStatusVMCommandPending OBJECT-TYPE + SYNTAX INTEGER { + commandPendingMasterTrueVM (1), + commandPendingMasterFalseVM (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return commandPendingMasterTrueVM (1) + if the MasterSwitch VM has a pending command on any of its + outlets. + + commandPendingMasterFalseVM (2) will be returned if there are + no pending commands." + ::= { sPDUMasterStatusVMEntry 3 } + +sPDUMasterStatusVMOverloadCondition OBJECT-TYPE + SYNTAX INTEGER { + overloadConditionTrueVM (1), + overloadConditionFalseVM (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return overloadConditionTrueVM (1) + if the sPDUMasterConfigVMHighLoadWarningThreshold OID is + violated. + + overloadConditionFalseVM (2) will be returned if the + sPDUMasterConfigVMHighLoadWarningThreshold OID is not + violated." + ::= { sPDUMasterStatusVMEntry 4 } + +sPDUMasterStatusVMLowLoadCondition OBJECT-TYPE + SYNTAX INTEGER { + lowLoadConditionTrueVM (1), + lowLoadConditionFalseVM (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return lowLoadConditionTrueVM (1) + if the sPDUMasterConfigVMLowLoadWarningThreshold OID is + violated. + + lowLoadConditionFalseVM (2) will be returned if the + sPDUMasterConfigVMHighLoadWarningThreshold OID is not + violated. " + ::= { sPDUMasterStatusVMEntry 5 } + +sPDUMasterStatusVMCurrentLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the total amount of power + being consumed by the load. It is represented as a + percentage of full load." + ::= { sPDUMasterStatusVMEntry 6 } + +sPDUMasterStatusVMMaxLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the total amount of power + that this MasterSwitch VM can provide. It is represented + in Amps." + ::= { sPDUMasterStatusVMEntry 7 } + +sPDUMasterStatusVMOutletCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the number of controllable + outlets for this MasterSwitch VM." + ::= { sPDUMasterStatusVMEntry 8 } + +sPDUMasterStatusVMRebootDuration OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the largest + sPDUOutletConfigVMRebootDuration OID time + for this MasterSwitch VM." + ::= { sPDUMasterStatusVMEntry 9 } + +-- the sPDUOutletControlVM group + + +sPDUOutletControlVMTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUOutletControlVMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for control of individual outlet switches. The number of + entries is contained in the sPDUMasterStatusOutletCount OID." + ::= { sPDUOutletControlVM 1 } + +sPDUOutletControlVMEntry OBJECT-TYPE + SYNTAX SPDUOutletControlVMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlets to control." + INDEX { sPDUOutletControlVMIndex, sPDUOutletControlVMOutletIndex } + ::= { sPDUOutletControlVMTable 1 } + +SPDUOutletControlVMEntry ::= + SEQUENCE { + sPDUOutletControlVMIndex INTEGER, + sPDUOutletControlVMName DisplayString, + sPDUOutletControlVMOutletIndex INTEGER, + sPDUOutletControlVMOutletName DisplayString, + sPDUOutletControlVMOutletCommand INTEGER + } + +sPDUOutletControlVMIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch VM." + ::= { sPDUOutletControlVMEntry 1 } + +sPDUOutletControlVMName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch VM. Maximum size is 23 characters. + This OID is provided for informational purposes only." + ::= { sPDUOutletControlVMEntry 2 } + +sPDUOutletControlVMOutletIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { sPDUOutletControlVMEntry 3 } + +sPDUOutletControlVMOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the outlet. Maximum size is 23 characters. + This OID is provided for informational purposes only." + ::= { sPDUOutletControlVMEntry 4 } + +sPDUOutletControlVMOutletCommand OBJECT-TYPE + SYNTAX INTEGER { + immediateOnVM (1), + immediateOffVM (2), + immediateRebootVM (3), + delayedOnVM (4), + delayedOffVM (5), + delayedRebootVM (6), + cancelPendingCommandVM (7) + + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this variable will return the outlet state. If + the outlet is on, the immediateOnVM (1) value will be returned. + If the outlet is off, the immediateOffVM (2) value will be + returned. + + + Setting this variable to immediateOnVM (1) will immediately turn the outlet on. + + Setting this variable to immediateOffVM (2) will immediately turn the outlet off. + + Setting this variable to immediateRebootVM (3) will immediately reboot the outlet. + + Setting this variable to delayedOnVM (4) will turn the outlet on + after the sPDUOutletConfigVMPowerOnTime OID time has elapsed. + + Setting this variable to delayedOffVM (5) will turn the outlet off + after the sPDUOutletConfigVMPowerOffTime OID time has elapsed. + + Setting this variable to delayedRebootVM (6) will cause the + MasterSwitch VM to perform a delayedOffVM command, wait the + sPDUOutletConfigVMRebootDuration OID time, and then perform the + immediateOnVM command. + + Setting this variable to cancelPendingCommandVM (7) will cause any + pending command to this outlet to be canceled." + ::= { sPDUOutletControlVMEntry 5 } + +-- the sPDUOutletConfigVM group + +sPDUOutletConfigVMTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUOutletConfigVMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of individual outlets. The number of + entries is contained in the sPDUMasterStatusOutletCount OID." + ::= { sPDUOutletConfigVM 1 } + +sPDUOutletConfigVMEntry OBJECT-TYPE + SYNTAX SPDUOutletConfigVMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlets to configure." + INDEX { sPDUOutletConfigVMIndex, sPDUOutletConfigVMOutletIndex } + ::= { sPDUOutletConfigVMTable 1 } + +SPDUOutletConfigVMEntry ::= + SEQUENCE { + sPDUOutletConfigVMIndex INTEGER, + sPDUOutletConfigVMName DisplayString, + sPDUOutletConfigVMOutletIndex INTEGER, + sPDUOutletConfigVMOutletName DisplayString, + sPDUOutletConfigVMPowerOnTime INTEGER, + sPDUOutletConfigVMPowerOffTime INTEGER, + sPDUOutletConfigVMRebootDuration INTEGER + } + +sPDUOutletConfigVMIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch VM." + ::= { sPDUOutletConfigVMEntry 1 } + +sPDUOutletConfigVMName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch VM. Maximum size is 23 characters." + ::= { sPDUOutletConfigVMEntry 2 } + +sPDUOutletConfigVMOutletIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { sPDUOutletConfigVMEntry 3 } + + +sPDUOutletConfigVMOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the outlet. Maximum size is 23 characters." + ::= { sPDUOutletConfigVMEntry 4 } + +sPDUOutletConfigVMPowerOnTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of time (in seconds) the outlet will delay + powering on at coldstart or when a command that requires + a turn-on delay is issued. + + Allowed values are: + + -1 never power on. + 0 power on immediately. + 15 power on 15 seconds after being commanded. + 30 power on 30 seconds after being commanded. + 45 power on 45 seconds after being commanded. + 60 power on 60 seconds (1 minute) after being commanded. + 120 power on 120 seconds (2 minutes) after being commanded. + 300 power on 300 seconds (5 minutes) after being commanded. + + If a value other than a supported value is provided in a + set request, the MasterSwitch VM interprets it as the next lower + acceptable value. If the provided value is lower than + the lowest acceptable value, the lowest acceptable + value is used." + ::= { sPDUOutletConfigVMEntry 5 } + + +sPDUOutletConfigVMPowerOffTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of time (in seconds) the outlet will delay + powering off when a command that requires + a turn-off delay is issued. + + + Allowed values are: + + -1 never power off automatically. + 0 power off immediately. + 15 power off 15 seconds after being commanded. + 30 power off 30 seconds after being commanded. + 45 power off 45 seconds after being commanded. + 60 power off 60 seconds (1 minute) after being commanded. + 120 power off 120 seconds (2 minutes) after being commanded. + 300 power off 300 seconds (5 minutes) after being commanded. + + If a value other than a supported value is provided in a + set request, the MasterSwitch VM interprets it as the next lower + acceptable value. If the provided value is lower than + the lowest acceptable value, the lowest acceptable + value is used." + ::= { sPDUOutletConfigVMEntry 6 } + +sPDUOutletConfigVMRebootDuration OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "During a reboot sequence, power is turned off and then + back on. This OID defines the amount of time to wait, + in seconds, after turning the power off, at the start + of the sequence, before turning power back on, at the + end of the reboot sequence. + + Allowed values are: + + 5 wait 5 seconds between off/on. + 10 wait 10 seconds between off/on. + 15 wait 15 seconds between off/on. + 20 wait 20 seconds between off/on. + 30 wait 30 seconds between off/on. + 45 wait 45 seconds between off/on. + 60 wait 60 seconds (1 minute) between off/on. + + If a value other than a supported value is provided in a + set request, the MasterSwitch VM interprets it as the next lower + acceptable value. If the provided value is lower than + the lowest acceptable value, the lowest acceptable + value is used." + ::= { sPDUOutletConfigVMEntry 7 } + +-- the sPDUOutletStatusVM group + +sPDUOutletStatusVMTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUOutletStatusVMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting of status of individual outlets. The number of + entries is contained in the sPDUMasterStatusOutletCount OID." + ::= { sPDUOutletStatusVM 1 } + +sPDUOutletStatusVMEntry OBJECT-TYPE + SYNTAX SPDUOutletStatusVMEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlets to gather status from." + INDEX { sPDUOutletStatusVMIndex, sPDUOutletStatusVMOutletIndex } + ::= { sPDUOutletStatusVMTable 1 } + +SPDUOutletStatusVMEntry ::= + SEQUENCE { + sPDUOutletStatusVMIndex INTEGER, + sPDUOutletStatusVMName DisplayString, + sPDUOutletStatusVMOutletIndex INTEGER, + sPDUOutletStatusVMOutletName DisplayString, + sPDUOutletStatusVMOutletState INTEGER, + sPDUOutletStatusVMCommandPending INTEGER + } + +sPDUOutletStatusVMIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch VM." + ::= { sPDUOutletStatusVMEntry 1 } + +sPDUOutletStatusVMName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch VM. Maximum size is 23 characters." + ::= { sPDUOutletStatusVMEntry 2 } + +sPDUOutletStatusVMOutletIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { sPDUOutletStatusVMEntry 3 } + +sPDUOutletStatusVMOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the outlet. Maximum size is 23 characters." + ::= { sPDUOutletStatusVMEntry 4 } + +sPDUOutletStatusVMOutletState OBJECT-TYPE + SYNTAX INTEGER { + outletStatusVMOn (1), + outletStatusVMOff (2) + } + + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the outlet state. If + the outlet is on, the outletStatusOnVM (1) value will be returned. + If the outlet is off, the outletStatusOffVM (2) value will be + returned. " + ::= { sPDUOutletStatusVMEntry 5 } + +sPDUOutletStatusVMCommandPending OBJECT-TYPE + SYNTAX INTEGER { + outletStatusVMCommandPending (1), + outletStatusVMNoCommandPending (2) + } + + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the command pending + state of the outlet. If a command is pending on the + outlet, the outletStatusVMCommandPending (1) value + will be returned. If there is not a command pending + on the outlet, the outletStatusVMNoCommandPending (2) + will be returned." + ::= { sPDUOutletStatusVMEntry 6 } + +-- the sPDUIdentMSP group + +sPDUIdentMSPTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of MasterSwitch pluses controllable + by this IP address." + ::= { sPDUIdentMSP 1 } + + +sPDUIdentMSPTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUIdentMSPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for query of the individual MasterSwitch pluses. + The number of entries is contained in the + sPDUIdentMSPTableSize OID." + ::= { sPDUIdentMSP 2 } + +sPDUIdentMSPEntry OBJECT-TYPE + SYNTAX SPDUIdentMSPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The MasterSwitch pluses to query." + INDEX { sPDUIdentMSPIndex} + ::= { sPDUIdentMSPTable 1 } + +SPDUIdentMSPEntry ::= + SEQUENCE { + sPDUIdentMSPIndex INTEGER, + sPDUIdentNameMSP DisplayString, + sPDUIdentHardwareRevMSP DisplayString, + sPDUIdentFirmwareRevMSP DisplayString, + sPDUIdentDateOfManufactureMSP DisplayString, + sPDUIdentModelNumberMSP DisplayString, + sPDUIdentSerialNumberMSP DisplayString + } + +sPDUIdentMSPIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch plus entry." + ::= { sPDUIdentMSPEntry 1 } + +sPDUIdentNameMSP OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch plus. The maximum + value is 23 characters. The name is set by + using the sPDUMasterConfigMSPName OID." + ::= { sPDUIdentMSPEntry 2 } + +sPDUIdentHardwareRevMSP OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware version of the MasterSwitch plus. + This value is set at the factory." + ::= { sPDUIdentMSPEntry 3 } + +sPDUIdentFirmwareRevMSP OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An 6-character ID string identifying the MasterSwitch plus + firmware version. This value is set at the factory." + ::= { sPDUIdentMSPEntry 4 } + +sPDUIdentDateOfManufactureMSP OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date when the MasterSwitch plus was manufactured in mm/dd/yyyy format. + This value is set at the factory. " + ::= { sPDUIdentMSPEntry 5 } + +sPDUIdentModelNumberMSP OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A 17-character string identifying the model number of + the MasterSwitch plus. This value is set at the factory." + ::= { sPDUIdentMSPEntry 6 } + +sPDUIdentSerialNumberMSP OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A 17-character string identifying the serial number of + the MasterSwitch plus. This value is set at the factory." + ::= { sPDUIdentMSPEntry 7 } + + +-- the sPDUMasterControlMSP group + +sPDUMasterControlMSPTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of MasterSwitch pluses controllable + by this IP address." + ::= { sPDUMasterControlMSP 1 } + +sPDUMasterControlMSPTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUMasterControlMSPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for control of the individual MasterSwitch pluses. + The number of entries is contained in the + sPDUMasterControlMSPTableSize OID." + ::= { sPDUMasterControlMSP 2 } + +sPDUMasterControlMSPEntry OBJECT-TYPE + SYNTAX SPDUMasterControlMSPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The MasterSwitch pluses to control." + INDEX { sPDUMasterControlMSPIndex} + ::= { sPDUMasterControlMSPTable 1 } + +SPDUMasterControlMSPEntry ::= + SEQUENCE { + sPDUMasterControlMSPIndex INTEGER, + sPDUMasterControlMSPName DisplayString, + sPDUMasterControlMSPCommand INTEGER + } + +sPDUMasterControlMSPIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch plus entry." + ::= { sPDUMasterControlMSPEntry 1 } + +sPDUMasterControlMSPName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch plus. The maximum + value is 23 characters. The name is set by + using the sPDUMasterConfigMSPName OID." + ::= { sPDUMasterControlMSPEntry 2 } + +sPDUMasterControlMSPCommand OBJECT-TYPE + SYNTAX INTEGER { + noCommandAllMSP (1), + immediateAllOnMSP (2), + sequencedAllOnMSP (3), + immediateAllOffMSP (4), + gracefulAllRebootMSP (5), + immediateAllRebootMSP (6), + gracefulAllShutdownMSP (7), + overrideAllBatCapThreshMSP (8), + cancelAllPendingCommandsMSP (9), + restoreFactoryDefaultsMSP (10) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to immediateAllOnMSP (2) will turn all outlets + on immediately. + + Setting this OID to sequencedAllOnMSP (3) will turn all outlets + on as defined by each outlet's sPDUOutletConfigMSPPowerOnDelay OID value. + + Setting this OID to immediateAllOffMSP (4) will turn all outlets + off immediately. + + Setting this OID to gracefulAllRebootMSP (5) will reboot all outlets + (after the device running PowerChute confirms shutdown) as defined + by each outlet's sPDUOutletConfigMSPRebootDuration OID time value. + + Setting this OID to immediateAllRebootMSP (6) will reboot all outlets + immediately. + + Setting this OID to gracefulAllShutdownMSP (7) will shutdown all outlets + (after the device running PowerChute confirms shutdown) as defined + by each outlet's sPDUOutletConfigMSPPowerOffDelay OID time value. Each + outlet will then turn on after the sum of its + sPDUOutletConfigMSPRestartDelay and sPDUOutletConfigMSPPowerOnDelay OID + values. + + Setting this OID to overrideAllBatCapThreshMSP (8) will cause the + outlet to ignore the Battery Capacity Threshold and proceed turning on + the outlets as defined by each outlet's sPDUOutletConfigMSPPowerOnDelay + OID value. + + Setting this OID to cancelAllPendingCommandsMSP (9) will cause all pending + commands on the MasterSwitch plus to be canceled. + + Setting this OID to restoreFactoryDefaultsMSP (10) will cause the settings of + the MasterSwitch plus to be restored to the factory defaults. + + Getting this OID will return the noCommandAllMSP (1) value." + ::= { sPDUMasterControlMSPEntry 3 } + + +-- the sPDUMasterConfigMSP group + +sPDUMasterConfigMSPTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of MasterSwitch pluses configurable + by this IP address." + ::= { sPDUMasterConfigMSP 1 } + +sPDUMasterConfigMSPTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUMasterConfigMSPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of the individual MasterSwitch pluses. + The number of entries is contained in the + sPDUMasterConfigMSPTableSize OID." + ::= { sPDUMasterConfigMSP 2 } + +sPDUMasterConfigMSPEntry OBJECT-TYPE + SYNTAX SPDUMasterConfigMSPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The MasterSwitch pluses to configure." + INDEX { sPDUMasterConfigMSPIndex} + ::= { sPDUMasterConfigMSPTable 1 } + +SPDUMasterConfigMSPEntry ::= + SEQUENCE { + sPDUMasterConfigMSPIndex INTEGER, + sPDUMasterConfigMSPName DisplayString, + sPDUMasterConfigMSPPowerOnTimeDelay INTEGER, + sPDUMasterConfigMSPManualButton INTEGER + } + +sPDUMasterConfigMSPIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch plus entry." + ::= { sPDUMasterConfigMSPEntry 1 } + +sPDUMasterConfigMSPName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch plus. Maximum size is 23 characters." + ::= { sPDUMasterConfigMSPEntry 2 } + +sPDUMasterConfigMSPPowerOnTimeDelay OBJECT-TYPE + SYNTAX INTEGER (0..9999) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " The amount of delay, in seconds, between when + power is provided to the MasterSwitch plus and + when the MasterSwitch plus provides basic master + power to the outlets. + + Allowed values are: + + 0 - 9999 seconds (0 - 2hrs, 46 mins, 39 secs). + 0 indicates to apply power immediately." + ::= { sPDUMasterConfigMSPEntry 3 } + + +sPDUMasterConfigMSPManualButton OBJECT-TYPE + SYNTAX INTEGER { + manualButtonDisabled (1), + manualButtonEnabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to manualButtonDisabled (1) will disable + the manual button on the MasterSwitch plus. + + Setting this OID to manualButtonEnabled (2) will enable + the manual button on the MasterSwitch plus." + ::= { sPDUMasterConfigMSPEntry 4 } + +-- the sPDUMasterStatusMSP group + +sPDUMasterStatusMSPTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of MasterSwitch pluses at + this IP address." + ::= { sPDUMasterStatusMSP 1 } + + +sPDUMasterStatusMSPTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUMasterStatusMSPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for gathering of status from the individual + MasterSwitch pluses. The number of entries is contained + in the sPDUMasterStatusMSPTableSize OID." + ::= { sPDUMasterStatusMSP 2 } + +sPDUMasterStatusMSPEntry OBJECT-TYPE + SYNTAX SPDUMasterStatusMSPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The MasterSwitch pluses to gather status from." + INDEX { sPDUMasterStatusMSPIndex} + ::= { sPDUMasterStatusMSPTable 1 } + +SPDUMasterStatusMSPEntry ::= + SEQUENCE { + sPDUMasterStatusMSPIndex INTEGER, + sPDUMasterStatusMSPName DisplayString, + sPDUMasterStatusMSPOutletCount INTEGER + } + +sPDUMasterStatusMSPIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch plus entry." + ::= { sPDUMasterStatusMSPEntry 1 } + +sPDUMasterStatusMSPName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch plus. The maximum + value is 23 characters. The name is set by + using the sPDUMasterConfigMSPName OID." + ::= { sPDUMasterStatusMSPEntry 2 } + +sPDUMasterStatusMSPOutletCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the number of controllable + outlets for this MasterSwitch plus." + ::= { sPDUMasterStatusMSPEntry 3 } + +-- the sPDUOutletControlMSP group + +sPDUOutletControlMSPTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUOutletControlMSPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for control of individual outlet switches. The number of + entries is contained in the sPDUMasterStatusMSPOutletCount OID." + ::= { sPDUOutletControlMSP 1 } + +sPDUOutletControlMSPEntry OBJECT-TYPE + SYNTAX SPDUOutletControlMSPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlets to control." + INDEX { sPDUOutletControlMSPIndex, sPDUOutletControlMSPOutletIndex } + ::= { sPDUOutletControlMSPTable 1 } + +SPDUOutletControlMSPEntry ::= + SEQUENCE { + sPDUOutletControlMSPIndex INTEGER, + sPDUOutletControlMSPName DisplayString, + sPDUOutletControlMSPOutletIndex INTEGER, + sPDUOutletControlMSPOutletName DisplayString, + sPDUOutletControlMSPOutletCommand INTEGER + } + +sPDUOutletControlMSPIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch plus." + ::= { sPDUOutletControlMSPEntry 1 } + +sPDUOutletControlMSPName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch plus. The maximum + value is 23 characters. The name is set by + using the sPDUMasterConfigMSPName OID." + ::= { sPDUOutletControlMSPEntry 2 } + +sPDUOutletControlMSPOutletIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { sPDUOutletControlMSPEntry 3 } + +sPDUOutletControlMSPOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the outlet. The maximum size is + 23 characters. The name is set by using the + sPDUOutletConfigMSPallOutletName OID. + This OID is provided for informational purposes only." + ::= { sPDUOutletControlMSPEntry 4 } + +sPDUOutletControlMSPOutletCommand OBJECT-TYPE + SYNTAX INTEGER { + immediateOnMSP (1), + delayedOnMSP (2), + immediateOffMSP (3), + gracefulRebootMSP (4), + immediateRebootMSP (5), + gracefulshutdownMSP (6), + overrideBatCapThreshMSP (7), + cancelPendingCommandMSP (8) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this variable will return the outlet state. If + the outlet is on, the immediateOnMSP (1) value will be returned. + If the outlet is off, the immediateOffMSP (3) value will be + returned. + + Setting this variable to immediateOnMSP (1) will immediately turn the outlet on. + + Setting this variable to delayedOnMSP (2) will turn the outlet on + after the sPDUOutletConfigMSPPowerOnDelay OID time has elapsed. + + Setting this variable to immediateOffMSP (3) will immediately turn the outlet off. + + Setting this variable to gracefulRebootMSP (4) will cause the outlet to wait for + device confirmation (if applicable) and then turn the outlet off after the + sPDUOutletConfigMSPPowerOffDelay OID time has elapsed. The outlet will then turn + on after the sPDUOutletConfigMSPRebootDuration OID time has elapsed. + + Setting this variable to immediateRebootMSP (5) will immediately reboot the outlet. + + Setting this variable to gracefulshutdownMSP (6) will cause the outlet to wait for + device confirmation (if applicable) and then turn the outlet off after the + sPDUOutletConfigMSPPowerOffDelay OID time has elapsed. The outlet will then turn + on after the sum of the sPDUOutletConfigMSPRestartTime OID time and the + sPDUOutletConfigMSPPowerOnDelay OID time has elapsed. + + Setting this variable to overrideBatCapThreshMSP (7) will cause the outlet to + ignore the Battery Capacity Threshold and proceed waiting on the + sPDUOutletConfigMSPPowerOnDelay OID time before turning the outlet on. + + Setting this variable to cancelPendingCommandMSP (8) will cause any + pending command to this outlet to be canceled." + ::= { sPDUOutletControlMSPEntry 5 } + +-- the sPDUOutletConfigMSPall group + +sPDUOutletConfigMSPallTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUOutletConfigMSPallEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of individual outlets. The number of + entries is contained in the sPDUMasterStatusMSPOutletCount OID." + ::= { sPDUOutletConfigMSPall 1 } + +sPDUOutletConfigMSPallEntry OBJECT-TYPE + SYNTAX SPDUOutletConfigMSPallEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlets to configure." + INDEX { sPDUOutletConfigMSPallIndex, sPDUOutletConfigMSPallOutletIndex } + ::= { sPDUOutletConfigMSPallTable 1 } + +SPDUOutletConfigMSPallEntry ::= + SEQUENCE { + sPDUOutletConfigMSPallIndex INTEGER, + sPDUOutletConfigMSPallName DisplayString, + sPDUOutletConfigMSPallOutletIndex INTEGER, + sPDUOutletConfigMSPallOutletName DisplayString, + sPDUOutletConfigMSPallOutletCtrlMode INTEGER + } + +sPDUOutletConfigMSPallIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch plus." + ::= { sPDUOutletConfigMSPallEntry 1 } + +sPDUOutletConfigMSPallName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch plus. The maximum + value is 23 characters. The name is set by + using the sPDUMasterConfigMSPName OID." + ::= { sPDUOutletConfigMSPallEntry 2 } + +sPDUOutletConfigMSPallOutletIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { sPDUOutletConfigMSPallEntry 3 } + +sPDUOutletConfigMSPallOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the outlet. Maximum size is 23 characters." + ::= { sPDUOutletConfigMSPallEntry 4 } + +sPDUOutletConfigMSPallOutletCtrlMode OBJECT-TYPE + SYNTAX INTEGER { + modeGracefulShutdown (1), + modeAnnunciator (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to modeGracefulShutdown (1) will put this + outlet into the Graceful Shutdown control mode. + + Setting this OID to modeAnnunciator (2) will put this outlet + into the Annunciator control mode." + ::= { sPDUOutletConfigMSPallEntry 5 } + + +-- the sPDUOutConfigMSPgs group + +sPDUOutletConfigMSPgsTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUOutletConfigMSPgsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of individual outlets. The number of + entries is contained in the sPDUMasterStatusMSPOutletCount OID." + ::= { sPDUOutletConfigMSPgs 1 } + +sPDUOutletConfigMSPgsEntry OBJECT-TYPE + SYNTAX SPDUOutletConfigMSPgsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlets to configure." + INDEX { sPDUOutletConfigMSPgsIndex, sPDUOutletConfigMSPgsOutletIndex } + ::= { sPDUOutletConfigMSPgsTable 1 } + +SPDUOutletConfigMSPgsEntry ::= + SEQUENCE { + sPDUOutletConfigMSPgsIndex INTEGER, + sPDUOutletConfigMSPgsName DisplayString, + sPDUOutletConfigMSPgsOutletIndex INTEGER, + sPDUOutletConfigMSPgsOutletName DisplayString, + sPDUOutletConfigMSPgsOutletCtrlMode INTEGER, + sPDUOutletConfigMSPgsDeviceConfirm INTEGER, + sPDUOutletConfigMSPgsLowBattWarning INTEGER, + sPDUOutletConfigMSPgsLowBattMult INTEGER, + sPDUOutletConfigMSPgsRestartDelay INTEGER, + sPDUOutletConfigMSPgsPowerOnDelay INTEGER, + sPDUOutletConfigMSPgsPowerOffDelay INTEGER, + sPDUOutletConfigMSPgsBattCapThresh INTEGER, + sPDUOutletConfigMSPgsRebootDuration INTEGER + } + +sPDUOutletConfigMSPgsIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch plus." + ::= { sPDUOutletConfigMSPgsEntry 1 } + +sPDUOutletConfigMSPgsName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch plus. The maximum + value is 23 characters. The name is set by + using the sPDUMasterConfigMSPName OID." + ::= { sPDUOutletConfigMSPgsEntry 2 } + +sPDUOutletConfigMSPgsOutletIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { sPDUOutletConfigMSPgsEntry 3 } + +sPDUOutletConfigMSPgsOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the outlet. The maximum size is + 23 characters. The name is set by using the + sPDUOutletConfigMSPallOutletName OID. + This OID is provided for informational purposes only." + ::= { sPDUOutletConfigMSPgsEntry 4 } + +sPDUOutletConfigMSPgsOutletCtrlMode OBJECT-TYPE + SYNTAX INTEGER { + modeGracefulShutdown (1), + modeAnnunciator (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Control Mode of the outlet. + This OID is provided for informational purposes only." + ::= { sPDUOutletConfigMSPgsEntry 5 } + +sPDUOutletConfigMSPgsDeviceConfirm OBJECT-TYPE + SYNTAX INTEGER { + deviceConfirmNo (1), + deviceConfirmYes (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to deviceConfirmNo (1) cause the outlet to + NOT wait for device confirmation while performing graceful + operations. + + Setting this OID to deviceConfirmYes (2) cause the outlet to + wait for device confirmation while performing graceful + operations." + ::= { sPDUOutletConfigMSPgsEntry 6 } + +sPDUOutletConfigMSPgsLowBattWarning OBJECT-TYPE + SYNTAX INTEGER (-2..9999) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " The amount of delay, in 6 second intervals, between + when the UPS goes on battery and the power down sequence for + the outlet is initiated. + + Allowed values are: + + -2 - Never initiate the power down sequence on low battery warning. + -1 - Initiate power down sequence based on remaining runtime. + 1 - 9999 six second intervals (6 secs - 16hrs, 39 mins, 54 secs). + 0 indicates to immediately initiate power down sequence on low + battery warning." + ::= { sPDUOutletConfigMSPgsEntry 7 } + +sPDUOutletConfigMSPgsLowBattMult OBJECT-TYPE + SYNTAX INTEGER (1..7) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " Only applicable if sPDUOutletConfigMSPgsLowBattWarning OID is + set to -1 (On Runtime Remaining). + + Allows you to set the value to stagger the shutdown sequence of the outlets. + 1 provides the longest delay (the outlet to shutoff first), and 7 would + provide the shortest delay (the outlet to shut off last). + + Allowed values are: + 1 - 7." + ::= { sPDUOutletConfigMSPgsEntry 8 } + +sPDUOutletConfigMSPgsRestartDelay OBJECT-TYPE + SYNTAX INTEGER (-1..9999) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " The amount of delay, in 6 minute intervals, between + when the outlet is turned off and the outlet is turned back on + when performing a Graceful Shutdown. + + Allowed values are: + + -1 - Never turn outlet back on after a Graceful shutdown. + 0 - 9999 six minute intervals (0 - 999hrs, 54 mins)." + ::= { sPDUOutletConfigMSPgsEntry 9 } + +sPDUOutletConfigMSPgsPowerOnDelay OBJECT-TYPE + SYNTAX INTEGER (-1..9999) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " The amount of delay, in seconds, between the UPS entering + normal (on-line) state and the outlet being powered on. + + Allowed values are: + + -1 - Remain Off when the UPS enters the on-line state. + 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs)." + ::= { sPDUOutletConfigMSPgsEntry 10 } + + +sPDUOutletConfigMSPgsPowerOffDelay OBJECT-TYPE + SYNTAX INTEGER (0..9999) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " The amount of delay, in seconds, between when the server + shuts down and the outlet is powered off. + + Allowed values are: + + 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs)." + ::= { sPDUOutletConfigMSPgsEntry 11 } + +sPDUOutletConfigMSPgsBattCapThresh OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " The minimum battery capacity, as a percent (0-100%), required + of the UPS before an outlet will be allowed to power on. + + Allowed values are: + + 0 - 100 percent." + ::= { sPDUOutletConfigMSPgsEntry 12 } + +sPDUOutletConfigMSPgsRebootDuration OBJECT-TYPE + SYNTAX INTEGER (0..9999) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " The amount of delay, in seconds, from outlet off until + outlet on during a reboot. + + Allowed values are: + + 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs)." + ::= { sPDUOutletConfigMSPgsEntry 13 } + + +-- the sPDUOutConfigMSPannun group + +sPDUOutletConfigMSPannunTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUOutletConfigMSPannunEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of individual outlets. The number of + entries is contained in the sPDUMasterStatusMSPOutletCount OID." + ::= { sPDUOutletConfigMSPannun 1 } + +sPDUOutletConfigMSPannunEntry OBJECT-TYPE + SYNTAX SPDUOutletConfigMSPannunEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlets to configure." + INDEX { sPDUOutletConfigMSPannunIndex, sPDUOutletConfigMSPannunOutletIndex } + ::= { sPDUOutletConfigMSPannunTable 1 } + +SPDUOutletConfigMSPannunEntry ::= + SEQUENCE { + sPDUOutletConfigMSPannunIndex INTEGER, + sPDUOutletConfigMSPannunName DisplayString, + sPDUOutletConfigMSPannunOutletIndex INTEGER, + sPDUOutletConfigMSPannunOutletName DisplayString, + sPDUOutletConfigMSPannunOutletCtrlMode INTEGER, + sPDUOutletConfigMSPannunInitialState INTEGER, + sPDUOutletConfigMSPannunAlarmActionDly INTEGER + } + +sPDUOutletConfigMSPannunIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch plus." + ::= { sPDUOutletConfigMSPannunEntry 1 } + +sPDUOutletConfigMSPannunName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch plus. The maximum + value is 23 characters. The name is set by + using the sPDUMasterConfigMSPName OID." + ::= { sPDUOutletConfigMSPannunEntry 2 } + +sPDUOutletConfigMSPannunOutletIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { sPDUOutletConfigMSPannunEntry 3 } + +sPDUOutletConfigMSPannunOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the outlet. The maximum size is + 23 characters. The name is set by using the + sPDUOutletConfigMSPallOutletName OID. + This OID is provided for informational purposes only." + ::= { sPDUOutletConfigMSPannunEntry 4 } + +sPDUOutletConfigMSPannunOutletCtrlMode OBJECT-TYPE + SYNTAX INTEGER { + modeGracefulShutdown (1), + modeAnnunciator (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Control Mode of the outlet. + This OID is provided for informational purposes only." + ::= { sPDUOutletConfigMSPannunEntry 5 } + +sPDUOutletConfigMSPannunInitialState OBJECT-TYPE + SYNTAX INTEGER { + initialStateOff (1), + initialStateOn (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to initialStateOff (1) causes the outlet + to default to off when in the non-alarmed condition. + + Setting this OID to initialStateOn (2) causes the outlet + to default to on when in the non-alarmed condition." + ::= { sPDUOutletConfigMSPannunEntry 6 } + +sPDUOutletConfigMSPannunAlarmActionDly OBJECT-TYPE + SYNTAX INTEGER (0..9999) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " The amount of time, in seconds, that an enabled Measure-UPS + alarm must be asserted before an alarm condition is recognized. + + Allowed values are: + + 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs)." + ::= { sPDUOutletConfigMSPannunEntry 7 } + + +-- the sPDUOutConfigMSPmups group + +sPDUOutletConfigMSPmupsTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUOutletConfigMSPmupsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of individual outlets. The number of + entries is contained in the sPDUMasterStatusMSPOutletCount OID." + ::= { sPDUOutletConfigMSPmups 1 } + +sPDUOutletConfigMSPmupsEntry OBJECT-TYPE + SYNTAX SPDUOutletConfigMSPmupsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlets to configure." + INDEX { sPDUOutletConfigMSPmupsIndex, sPDUOutletConfigMSPmupsOutletIndex } + ::= { sPDUOutletConfigMSPmupsTable 1 } + +SPDUOutletConfigMSPmupsEntry ::= + SEQUENCE { + sPDUOutletConfigMSPmupsIndex INTEGER, + sPDUOutletConfigMSPmupsName DisplayString, + sPDUOutletConfigMSPmupsOutletIndex INTEGER, + sPDUOutletConfigMSPmupsOutletName DisplayString, + sPDUOutletConfigMSPmupsZone1 INTEGER, + sPDUOutletConfigMSPmupsZone2 INTEGER, + sPDUOutletConfigMSPmupsZone3 INTEGER, + sPDUOutletConfigMSPmupsZone4 INTEGER, + sPDUOutletConfigMSPmupsP1LowHum INTEGER, + sPDUOutletConfigMSPmupsP1HiHum INTEGER, + sPDUOutletConfigMSPmupsP1LowTemp INTEGER, + sPDUOutletConfigMSPmupsP1HiTemp INTEGER, + sPDUOutletConfigMSPmupsP2LowHum INTEGER, + sPDUOutletConfigMSPmupsP2HiHum INTEGER, + sPDUOutletConfigMSPmupsP2LowTemp INTEGER, + sPDUOutletConfigMSPmupsP2HiTemp INTEGER + } + +sPDUOutletConfigMSPmupsIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch plus." + ::= { sPDUOutletConfigMSPmupsEntry 1 } + +sPDUOutletConfigMSPmupsName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch plus. The maximum + value is 23 characters. The name is set by + using the sPDUMasterConfigMSPName OID." + ::= { sPDUOutletConfigMSPmupsEntry 2 } + +sPDUOutletConfigMSPmupsOutletIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { sPDUOutletConfigMSPmupsEntry 3 } + +sPDUOutletConfigMSPmupsOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the outlet. The maximum size is + 23 characters. The name is set by using the + sPDUOutletConfigMSPallOutletName OID. + This OID is provided for informational purposes only." + ::= { sPDUOutletConfigMSPmupsEntry 4 } + +sPDUOutletConfigMSPmupsZone1 OBJECT-TYPE + SYNTAX INTEGER { + disableAlarm (1), + enableAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to disableAlarm (1) disables the + Zone 1 alarm for this outlet. + + Setting this OID to enableAlarm (2) enables the + Zone 1 alarm for this outlet." + ::= { sPDUOutletConfigMSPmupsEntry 5 } + +sPDUOutletConfigMSPmupsZone2 OBJECT-TYPE + SYNTAX INTEGER { + disableAlarm (1), + enableAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to disableAlarm (1) disables the + Zone 2 alarm for this outlet. + + Setting this OID to enableAlarm (2) enables the + Zone 2 alarm for this outlet." + ::= { sPDUOutletConfigMSPmupsEntry 6 } + +sPDUOutletConfigMSPmupsZone3 OBJECT-TYPE + SYNTAX INTEGER { + disableAlarm (1), + enableAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to disableAlarm (1) disables the + Zone 3 alarm for this outlet. + + Setting this OID to enableAlarm (2) enables the + Zone 3 alarm for this outlet." + ::= { sPDUOutletConfigMSPmupsEntry 7 } + +sPDUOutletConfigMSPmupsZone4 OBJECT-TYPE + SYNTAX INTEGER { + disableAlarm (1), + enableAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to disableAlarm (1) disables the + Zone 4 alarm for this outlet. + + Setting this OID to enableAlarm (2) enables the + Zone 4 alarm for this outlet." + ::= { sPDUOutletConfigMSPmupsEntry 8 } + +sPDUOutletConfigMSPmupsP1LowHum OBJECT-TYPE + SYNTAX INTEGER { + disableAlarm (1), + enableAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to disableAlarm (1) disables the + Probe 1 low humidity alarm for this outlet. + + Setting this OID to enableAlarm (2) enables the + Probe 1 low humidity alarm for this outlet." + ::= { sPDUOutletConfigMSPmupsEntry 9 } + +sPDUOutletConfigMSPmupsP1HiHum OBJECT-TYPE + SYNTAX INTEGER { + disableAlarm (1), + enableAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to disableAlarm (1) disables the + Probe 1 high humidity alarm for this outlet. + + Setting this OID to enableAlarm (2) enables the + Probe 1 high humidity alarm for this outlet." + ::= { sPDUOutletConfigMSPmupsEntry 10 } + +sPDUOutletConfigMSPmupsP1LowTemp OBJECT-TYPE + SYNTAX INTEGER { + disableAlarm (1), + enableAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to disableAlarm (1) disables the + Probe 1 low temperature alarm for this outlet. + + Setting this OID to enableAlarm (2) enables the + Probe 1 low temperature alarm for this outlet." + ::= { sPDUOutletConfigMSPmupsEntry 11 } + +sPDUOutletConfigMSPmupsP1HiTemp OBJECT-TYPE + SYNTAX INTEGER { + disableAlarm (1), + enableAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to disableAlarm (1) disables the + Probe 1 high temperature alarm for this outlet. + + Setting this OID to enableAlarm (2) enables the + Probe 1 high temperature alarm for this outlet." + ::= { sPDUOutletConfigMSPmupsEntry 12 } + +sPDUOutletConfigMSPmupsP2LowHum OBJECT-TYPE + SYNTAX INTEGER { + disableAlarm (1), + enableAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to disableAlarm (1) disables the + Probe 2 low humidity alarm for this outlet. + + Setting this OID to enableAlarm (2) enables the + Probe 2 low humidity alarm for this outlet." + ::= { sPDUOutletConfigMSPmupsEntry 13 } + +sPDUOutletConfigMSPmupsP2HiHum OBJECT-TYPE + SYNTAX INTEGER { + disableAlarm (1), + enableAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to disableAlarm (1) disables the + Probe 2 high humidity alarm for this outlet. + + Setting this OID to enableAlarm (2) enables the + Probe 2 high humidity alarm for this outlet." + ::= { sPDUOutletConfigMSPmupsEntry 14 } + +sPDUOutletConfigMSPmupsP2LowTemp OBJECT-TYPE + SYNTAX INTEGER { + disableAlarm (1), + enableAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to disableAlarm (1) disables the + Probe 2 low temperature alarm for this outlet. + + Setting this OID to enableAlarm (2) enables the + Probe 2 low temperature alarm for this outlet." + ::= { sPDUOutletConfigMSPmupsEntry 15 } + +sPDUOutletConfigMSPmupsP2HiTemp OBJECT-TYPE + SYNTAX INTEGER { + disableAlarm (1), + enableAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to disableAlarm (1) disables the + Probe 2 high temperature alarm for this outlet. + + Setting this OID to enableAlarm (2) enables the + Probe 2 high temperature alarm for this outlet." + ::= { sPDUOutletConfigMSPmupsEntry 16 } + +-- the sPDUOutletStatusMSP group + +sPDUOutletStatusMSPTable OBJECT-TYPE + SYNTAX SEQUENCE OF SPDUOutletStatusMSPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting of status of individual outlets. The number of + entries is contained in the sPDUMasterStatusOutletCount OID." + ::= { sPDUOutletStatusMSP 1 } + +sPDUOutletStatusMSPEntry OBJECT-TYPE + SYNTAX SPDUOutletStatusMSPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlets to gather status from." + INDEX { sPDUOutletStatusMSPIndex, sPDUOutletStatusMSPOutletIndex } + ::= { sPDUOutletStatusMSPTable 1 } + +SPDUOutletStatusMSPEntry ::= + SEQUENCE { + sPDUOutletStatusMSPIndex INTEGER, + sPDUOutletStatusMSPName DisplayString, + sPDUOutletStatusMSPOutletIndex INTEGER, + sPDUOutletStatusMSPOutletName DisplayString, + sPDUOutletStatusMSPOutletState INTEGER, + sPDUOutletStatusMSPCommandPending INTEGER, + sPDUOutletStatusMSPOutletCtrlMode INTEGER + } + +sPDUOutletStatusMSPIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the MasterSwitch MSP." + ::= { sPDUOutletStatusMSPEntry 1 } + +sPDUOutletStatusMSPName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the MasterSwitch plus. The maximum + value is 23 characters. The name is set by + using the sPDUMasterConfigMSPName OID." + ::= { sPDUOutletStatusMSPEntry 2 } + +sPDUOutletStatusMSPOutletIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { sPDUOutletStatusMSPEntry 3 } + +sPDUOutletStatusMSPOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the outlet. The maximum size is + 23 characters. The name is set by using the + sPDUOutletConfigMSPallOutletName OID. + This OID is provided for informational purposes only." + ::= { sPDUOutletStatusMSPEntry 4 } + +sPDUOutletStatusMSPOutletState OBJECT-TYPE + SYNTAX INTEGER { + outletStatusMSPOn (1), + outletStatusMSPOff (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the outlet state. If + the outlet is on, the outletStatusMSPOn (1) value will be returned. + If the outlet is off, the outletStatusMSPOff (2) value will be + returned. " + ::= { sPDUOutletStatusMSPEntry 5 } + +sPDUOutletStatusMSPCommandPending OBJECT-TYPE + SYNTAX INTEGER { + outletStatusMSPCommandPending (1), + outletStatusMSPNoCommandPending (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the command pending + state of the outlet. If a command is pending on the + outlet, the outletStatusMSPCommandPending (1) value + will be returned. If there is not a command pending + on the outlet, the outletStatusMSPNoCommandPending (2) + will be returned." + ::= { sPDUOutletStatusMSPEntry 6 } + +sPDUOutletStatusMSPOutletCtrlMode OBJECT-TYPE + SYNTAX INTEGER { + modeGracefulShutdown (1), + modeAnnunciator (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Control Mode of the outlet. + This OID is provided for informational purposes only." + ::= { sPDUOutletStatusMSPEntry 7 } + + +-- the rPDUIdent group + +rPDUIdentName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the Rack PDU. + The maximum string size is device dependent." + ::= { rPDUIdent 1 } + +rPDUIdentHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the Rack PDU. + This value is set at the factory." + ::= { rPDUIdent 2 } + +rPDUIdentFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An 8-byte ID string identifying the Rack PDU firmware revision. + This value is set at the factory." + ::= { rPDUIdent 3 } + + +rPDUIdentDateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date when the Rack PDU was manufactured in mm/dd/yyyy format. + This value is set at the factory. The year 2000 will be + represented by 00." + ::= { rPDUIdent 4 } + +rPDUIdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A 10-character string identifying the model number of + the Rack PDU. This value is set at the factory." + ::= { rPDUIdent 5 } + +rPDUIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A 12-character string identifying the serial number of + the Rack PDU. This value is set at the factory." + ::= { rPDUIdent 6 } + +rPDUIdentDeviceRating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the electrical rating of the device in Amps." + + ::= { rPDUIdent 7 } + +rPDUIdentDeviceNumOutlets OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the number of outlets contained in the device." + + ::= { rPDUIdent 8 } + +rPDUIdentDeviceNumPhases OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the number of phases supported by the device." + + ::= { rPDUIdent 9 } + +rPDUIdentDeviceNumBreakers OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the number of circuit breakers supported by the device. + This is the same as the number of banks of outlets. + 0 will be returned if the unit has no phase breakers. " + + ::= { rPDUIdent 10 } + +rPDUIdentDeviceBreakerRating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return rating of the circuit breakers + on the device in Amps if it has any." + + ::= { rPDUIdent 11 } + +rPDUIdentDeviceOrientation OBJECT-TYPE + SYNTAX INTEGER { + orientHorizontal (1), + orientVertical (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the intended physical orientation of the device. + + OrientHorizonatal(1) indicates Horizontal. + OrientVertical(2) indicates Vertical." + + ::= { rPDUIdent 12 } + +rPDUIdentDeviceOutletLayout OBJECT-TYPE + SYNTAX INTEGER { + seqPhaseToNeutral (1), + seqPhaseToPhase (2), + seqPhToNeu21PhToPh (3), + seqPhToPhGrouped (4), + seqPhToNGrouped (5), + seqPToN1516PToPGrouped (6), + seqPhToPh2xGrouped (7), + seqPhToN2xGrouped (8), + seqNotApplicable (9) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return outlet layout for the device. + + seqPhaseToNeutral(1) indicates outlet layout as follows: + 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... + + seqPhaseToPhase(2) indicates outlet layout as follows: + 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,... + + seqPhToNeu21PhToPh(3) indicates outlet layout as follows: + 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,... + + seqPhToPhGrouped(4) indicates outlet layout as follows: + For AP8xxx SKU's Group 1:1-2, Group 2:2-3, Group 3:3-1. + For AP7xxx SKU's Group 1:3-1. Group 2:2-3, Group 3:1-2. + + seqPhToNGrouped(5) indicates outlet layout as follows: + This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N. + + seqPToN1516PToPGrouped(6) indicates outlet layout as follows: + This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2, + Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1. + + seqPhToPh2xGrouped(7) indicates outlet layout as follows: + This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3, + Group 4:2-3, Group 5:3-1, Group 6:3-1. + + seqPhToN2xGrouped(8) indicates outlet layout as follows: + This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N, + Group 4:2-N, Group 5:3-N, Group 6:3-N. + + seqNotApplicable(9): + Outlet layout does not affect any of the user interfaces. + These SKUs may report seqNotApplicable(9) if there is + not an exact outlet layout match available." + ::= { rPDUIdent 13 } + +rPDUIdentDeviceDisplayOrientation OBJECT-TYPE + SYNTAX INTEGER { + displayNormal (1), + displayReverse (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this OID will return the intended physical orientation of the Seven-Segment Display. + + Normal(1) indicates Normal. + Reverse(2)indicates Upside-Down." + + ::= { rPDUIdent 14 } + + +rPDUIdentDeviceLinetoLineVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting/Setting this OID will return/set the Line to Line Voltage. + This OID defaults to the nominal input line voltage in volts AC. + This setting is used to calculate total power and must be configured for best accuracy. + This OID does not apply to AP86XX, AP88XX, or AP89XX SKUs. + + The valid range is between 0V to 440V" + ::= { rPDUIdent 15 } + +rPDUIdentDevicePowerWatts OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the Power in Watts." + + ::= { rPDUIdent 16 } + +rPDUIdentDevicePowerFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting/setting this OID will return/set the + Power Factor in thousanths (1000 is power factor of 1). + For AP8XXX SKUs, this OID is read-only + + Valid range is from 0 to 1000." + ::= { rPDUIdent 17 } + +rPDUIdentDevicePowerVA OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the Power in VA." + + ::= { rPDUIdent 18 } + +rPDUIdentDeviceLinetoNeutralVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting/Setting this OID will return/set the Line to Neutral Voltage. + This OID defaults to the nominal line to neutral voltage in volts AC. + This setting is used to calculate total power and must be configured for best accuracy. + This OID applies only to AP7823. For all other models, the OID is fixed at 0. + + The valid range is between 0V to 440V." + + ::= { rPDUIdent 19 } + +-- the rPDULoadDevice group + +rPDULoadDevMaxPhaseLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the maximum rated power + that each phase of the Rack PDU can provide. It is + represented in Amps. + + 0 will be returned if the unit is banked." + ::= { rPDULoadDevice 1 } + +rPDULoadDevNumPhases OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of phases available with this Rack PDU." + ::= { rPDULoadDevice 2 } + +rPDULoadDevMaxBankLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the maximum rated power + that a bank of the Rack PDU can provide. It is + represented in Amps. + + 0 will be returned if the device does not have any banks." + + ::= { rPDULoadDevice 3 } + +rPDULoadDevNumBanks OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of banks of outlets available with this Rack PDU. + A bank of outlets has a unique circuit breaker for a subset + of the total number of outlets on the rPDU. + + 0 will be returned if the unit has no banks." + ::= { rPDULoadDevice 4 } + +rPDULoadDevBankTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The size of the Bank Table." + ::= { rPDULoadDevice 5 } + + +rPDULoadDevBankTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDULoadDevBankEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting the Bank Max Load in the Rack PDU." + + ::= { rPDULoadDevice 6 } + +rPDULoadDevBankEntry OBJECT-TYPE + SYNTAX RPDULoadDevBankEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The Rack PDU Banks Access." + INDEX { rPDULoadDevBankIndex} + ::= { rPDULoadDevBankTable 1 } + +RPDULoadDevBankEntry ::= + SEQUENCE { + rPDULoadDevBankIndex INTEGER, + rPDULoadDevBankNumber INTEGER, + rPDULoadDevBankMaxLoad INTEGER + } + +rPDULoadDevBankIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU bank entry." + ::= { rPDULoadDevBankEntry 1 } + +rPDULoadDevBankNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the bank number." + + ::= { rPDULoadDevBankEntry 2 } + +rPDULoadDevBankMaxLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the maximum rated power + that each bank of the Rack PDU can provide. It is + represented in Amps." + + ::= { rPDULoadDevBankEntry 3 } + +rPDULoadDevMaxOutletTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The size of the Outlet Table." + ::= { rPDULoadDevice 7 } + + +rPDULoadDevMaxOutletTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDULoadDevMaxOutletEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting the Max Outlet Load in an Outlet Monitored Rack PDU." + ::= { rPDULoadDevice 8 } + +rPDULoadDevMaxOutletEntry OBJECT-TYPE + SYNTAX RPDULoadDevMaxOutletEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This gives access to Max Outlet Load of an Outlet Monitored Rack PDU" + INDEX { rPDULoadDevOutletIndex} + ::= { rPDULoadDevMaxOutletTable 1 } + +RPDULoadDevMaxOutletEntry ::= + SEQUENCE { + rPDULoadDevOutletIndex INTEGER, + rPDULoadDevOutletNumber INTEGER, + rPDULoadDevMaxOutletLoad INTEGER + } + +rPDULoadDevOutletIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Outlet Monitored Rack PDU Max Outlet Load entry." + ::= { rPDULoadDevMaxOutletEntry 1 } + +rPDULoadDevOutletNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the Outlet number." + ::= { rPDULoadDevMaxOutletEntry 2 } + + +rPDULoadDevMaxOutletLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the maximum rated power + that each Outlet of an Outlet Monitored Rack PDU can provide. It is + represented in Amps. " + ::= { rPDULoadDevMaxOutletEntry 3 } + + + +-- the rPDULoadPhaseConfig group + +rPDULoadPhaseConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDULoadPhaseConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of each Rack PDU phase. + The number of entries is contained in the + rPDULoadDevNumPhases OID." + ::= { rPDULoadPhaseConfig 1 } + +rPDULoadPhaseConfigEntry OBJECT-TYPE + SYNTAX RPDULoadPhaseConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The Rack PDU phase to configure." + INDEX { rPDULoadPhaseConfigIndex} + ::= { rPDULoadPhaseConfigTable 1 } + +RPDULoadPhaseConfigEntry ::= + SEQUENCE { + rPDULoadPhaseConfigIndex INTEGER, + rPDULoadPhaseConfigLowLoadThreshold INTEGER, + rPDULoadPhaseConfigNearOverloadThreshold INTEGER, + rPDULoadPhaseConfigOverloadThreshold INTEGER, + rPDULoadPhaseConfigAlarm INTEGER + } + +rPDULoadPhaseConfigIndex OBJECT-TYPE + SYNTAX INTEGER { + phase1 (1), + phase2 (2), + phase3 (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU phase entry." + ::= { rPDULoadPhaseConfigEntry 1 } + +rPDULoadPhaseConfigLowLoadThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the power consumption of + the load is nearing a low consumption condition. It is + represented in Amps. A warning will be issued when the + load is less than the threshold value. + + A threshold value of 0 Amps effectively disables this + warning. + + Maximum value must be less than the value returned + by the rPDULoadPhaseConfigNearOverloadThreshold OID." + ::= { rPDULoadPhaseConfigEntry 2 } + +rPDULoadPhaseConfigNearOverloadThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the power consumption of + the load is nearing an overload condition. It is + represented in Amps. A warning will be issued when the + load is greater than or equal to the threshold value. + + Minimum value must be greater than the value returned by + the rPDULoadPhaseConfigLowLoadThreshold OID. + + Maximum value must be less than or equal to the value + returned by the rPDULoadPhaseConfigOverloadThreshold OID." + ::= { rPDULoadPhaseConfigEntry 3 } + +rPDULoadPhaseConfigOverloadThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the power consumption of + the load has entered an overload condition. It is + represented in Amps. A warning will be issued when the + load is greater than or equal to the threshold value. + + Minimum value must be greater than or equal to the value + returned by the rPDULoadPhaseConfigNearOverloadThreshold OID. + + Maximum value must be less than or equal to the value + returned by the rPDULoadDevMaxPhaseLoad OID." + ::= { rPDULoadPhaseConfigEntry 4 } + + +rPDULoadPhaseConfigAlarm OBJECT-TYPE + SYNTAX INTEGER { + noLoadAlarm (1), + underCurrentAlarm (2), + nearOverCurrentAlarm (3), + overCurrentAlarm (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the current Phase Alarm." + ::= { rPDULoadPhaseConfigEntry 5 } + + + + + +-- the rPDULoadStatus group + +rPDULoadStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDULoadStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting of status of each Rack PDU phase/bank. + The number of entries is calculated by adding + the number of phases (rPDULoadDevNumPhases OID) and + the number of banks of outlets (rPDULoadDevNumBanks) + Number of entries = #phases + #banks. + NOTE: If a device has phase and bank information, all phase information + shall precede the bank information. If a device has total information, + it shall precede both the bank and the phase information." + ::= { rPDULoadStatus 1 } + +rPDULoadStatusEntry OBJECT-TYPE + SYNTAX RPDULoadStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The Rack PDU phase/bank to gather status from." + INDEX { rPDULoadStatusIndex} + ::= { rPDULoadStatusTable 1 } + +RPDULoadStatusEntry ::= + SEQUENCE { + rPDULoadStatusIndex INTEGER, + rPDULoadStatusLoad Gauge, + rPDULoadStatusLoadState INTEGER, + rPDULoadStatusPhaseNumber INTEGER, + rPDULoadStatusBankNumber INTEGER + } + +rPDULoadStatusIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU phase/bank entry. All phase information will precede + any bank information" + ::= { rPDULoadStatusEntry 1 } + +rPDULoadStatusLoad OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the phase/bank load measured + in tenths of Amps." + ::= { rPDULoadStatusEntry 2 } + +rPDULoadStatusLoadState OBJECT-TYPE + SYNTAX INTEGER { + phaseLoadNormal (1), + phaseLoadLow (2), + phaseLoadNearOverload (3), + phaseLoadOverload (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the phase/bank load state. + + phaseLoadNormal(1) indicates that the phase/bank is + operating properly within the rPDULoadConfigLowLoadThreshold + and rPDULoadConfigNearOverloadThreshold OID values. + + phaseLoadLow(2) indicates that the phase/bank load has + dropped below the rPDULoadConfigLowLoadThreshold OID value. + An SNMP trap will occur when this state is entered or cleared. + + phaseLoadNearOverload(3) indicates that the phase/bank load + is greater than or equal to the + rPDULoadConfigNearOverloadThreshold OID value. + An SNMP trap will occur when this state is entered or cleared. + + phaseLoadOverload(4) indicates that the phase/bank load is + greater than or equal to the rPDULoadConfigOverloadThreshold + OID value. + An SNMP trap will occur when this state is entered or cleared." + ::= { rPDULoadStatusEntry 3 } + +rPDULoadStatusPhaseNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The phase number to which this record refers." + ::= { rPDULoadStatusEntry 4 } + +rPDULoadStatusBankNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The bank number to which this record refers. A value of 0 will be returned if + any bank is not present or if it is phase related." + ::= { rPDULoadStatusEntry 5 } + + +-- the rPDULoadBankConfig group + +rPDULoadBankConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDULoadBankConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of each Rack PDU bank. + The number of entries is contained in the + rPDULoadDevNumBanks OID." + ::= { rPDULoadBankConfig 1 } + +rPDULoadBankConfigEntry OBJECT-TYPE + SYNTAX RPDULoadBankConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The Rack PDU bank to configure." + INDEX { rPDULoadBankConfigIndex} + ::= { rPDULoadBankConfigTable 1 } + +RPDULoadBankConfigEntry ::= + SEQUENCE { + rPDULoadBankConfigIndex INTEGER, + rPDULoadBankConfigLowLoadThreshold INTEGER, + rPDULoadBankConfigNearOverloadThreshold INTEGER, + rPDULoadBankConfigOverloadThreshold INTEGER, + rPDULoadBankConfigAlarm INTEGER + } + +rPDULoadBankConfigIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU bank entry." + ::= { rPDULoadBankConfigEntry 1 } + +rPDULoadBankConfigLowLoadThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the power consumption of + the load is nearing a low consumption condition. It is + represented in Amps. A warning will be issued when the + load is less than the threshold value. + + A threshold value of 0 Amps effectively disables this + warning. + + Maximum value must be less than the value returned + by the rPDULoadBankConfigNearOverloadThreshold OID." + + ::= { rPDULoadBankConfigEntry 2 } + +rPDULoadBankConfigNearOverloadThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the power consumption of + the load is nearing an overload condition. It is + represented in Amps. A warning will be issued when the + load is greater than or equal to the threshold value. + + Minimum value must be greater than the value returned by + the rPDULoadBankConfigLowLoadThreshold OID. + + Maximum value must be less than or equal to the value + returned by the rPDULoadBankConfigOverloadThreshold OID." + + ::= { rPDULoadBankConfigEntry 3 } + +rPDULoadBankConfigOverloadThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the power consumption of + the load has entered an overload condition. It is + represented in Amps. A warning will be issued when the + load is greater than or equal to the threshold value. + + Minimum value must be greater than or equal to the value + returned by the rPDULoadBankConfigNearOverloadThreshold OID. + + Maximum value must be less than or equal to the value + returned by the rPDULoadDevMaxBankLoad OID." + + ::= { rPDULoadBankConfigEntry 4 } + +rPDULoadBankConfigAlarm OBJECT-TYPE + SYNTAX INTEGER { + noLoadAlarm (1), + underCurrentAlarm (2), + nearOverCurrentAlarm (3), + overCurrentAlarm (4) + + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + " Getting this OID will return the current Bank Alarm." + ::= { rPDULoadBankConfigEntry 5 } + + +-- the rPDUOutletDevice group + +rPDUOutletDevCommand OBJECT-TYPE + SYNTAX INTEGER { + noCommandAll (1), + immediateAllOn (2), + immediateAllOff (3), + immediateAllReboot (4), + delayedAllOn (5), + delayedAllOff (6), + delayedAllReboot (7), + cancelAllPendingCommands (8) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to immediateAllOn (2) will turn all outlets + on immediately. + + Setting this OID to immediateAllOff (3) will turn all outlets + off immediately. + + Setting this OID to immediateAllReboot (4) will reboot all outlets + immediately. + + Setting this OID to delayedAllOn (5) will turn all outlets on as + defined by each outlet's rPDUOutletConfigPowerOnTime OID value. + + Setting this OID to delayedAllOff (6) will turn all outlets + off as defined by each outlet's rPDUOutletConfigPowerOffTime OID value. + + Setting this OID to delayedAllReboot (7) will cause a + delayedAllOff command to be performed. Once all outlets are off, + the Switched Rack PDU will then delay the largest + rPDUOutletConfigRebootDuration OID time, and then perform a + delayedAllOn command. + + Setting this OID to cancelAllPendingCommands (8) will cause all pending + commands on the Switched Rack PDU to be canceled. + + Getting this OID will return the noCommandAll (1) value." + ::= { rPDUOutletDevice 1 } + +rPDUOutletDevColdstartDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of delay, in seconds, between when + power is provided to the Switched Rack PDU and + when the Switched Rack PDU provides basic master + power to the outlets. + + Allowed values are: + + -1 - never apply power automatically. + 0 - apply power immediately. + 1 to 300 - delay up to 300 seconds (5 minutes)." + ::= { rPDUOutletDevice 2 } + +rPDUOutletDevNumCntrlOutlets OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of controlled outlets on this Switched Rack PDU." + ::= { rPDUOutletDevice 3 } + +rPDUOutletDevNumTotalOutlets OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of outlets on this Rack PDU." + ::= { rPDUOutletDevice 4 } + +rPDUOutletDevMonitoredOutlets OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of monitored outlets on this Rack PDU." + ::= { rPDUOutletDevice 5 } + + +-- the rPDUOutletPhase group + +rPDUOutletPhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDUOutletPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for management of outlets on a per phase basis." + ::= { rPDUOutletPhase 1 } + +rPDUOutletPhaseEntry OBJECT-TYPE + SYNTAX RPDUOutletPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The phase to manage." + INDEX { rPDUOutletPhaseIndex} + ::= { rPDUOutletPhaseTable 1 } + +RPDUOutletPhaseEntry ::= + SEQUENCE { + rPDUOutletPhaseIndex INTEGER, + rPDUOutletPhaseOverloadRestriction INTEGER + } + +rPDUOutletPhaseIndex OBJECT-TYPE + SYNTAX INTEGER { + phase1 (1), + phase2 (2), + phase3 (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Switched Rack PDU phase entry." + ::= { rPDUOutletPhaseEntry 1 } + +rPDUOutletPhaseOverloadRestriction OBJECT-TYPE + SYNTAX INTEGER { + alwaysAllowTurnON (1), + restrictOnNearOverload (2), + restrictOnOverload (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This OID controls the behavior of a Switched Rack PDU + phase when an overload condition is possible and + additional outlets are requested to be turned on. + + Setting this OID to alwaysAllowTurnON (1) will always allow + the outlets on the corresponding phase to turn on. + + Setting this OID to restrictOnNearOverload (2) will not allow + outlets on the corresponding phase to turn on if the + rPDULoadConfigNearOverloadThreshold OID is exceeded. + + Setting this OID to restrictOnOverload (3) will not allow + outlets on the corresponding phase to turn on if the + rPDULoadConfigOverloadThreshold OID is exceeded." + ::= { rPDUOutletPhaseEntry 2 } + + +-- the rPDUOutletControl group + +rPDUOutletControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDUOutletControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for control of the individual outlets. + The number of entries is contained in the + rPDUOutletDevNumCntrlOutlets OID." + ::= { rPDUOutletControl 1 } + +rPDUOutletControlEntry OBJECT-TYPE + SYNTAX RPDUOutletControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlet to control." + INDEX { rPDUOutletControlIndex} + ::= { rPDUOutletControlTable 1 } + +RPDUOutletControlEntry ::= + SEQUENCE { + rPDUOutletControlIndex INTEGER, + rPDUOutletControlOutletName DisplayString, + rPDUOutletControlOutletPhase INTEGER, + rPDUOutletControlOutletCommand INTEGER, + rPDUOutletControlOutletBank INTEGER + } + +rPDUOutletControlIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { rPDUOutletControlEntry 1 } + +rPDUOutletControlOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the outlet. The maximum string size is device dependent. + An error will be returned if the set request exceeds the max size. + This OID is provided for informational purposes only." + ::= { rPDUOutletControlEntry 2 } + +rPDUOutletControlOutletPhase OBJECT-TYPE + SYNTAX INTEGER { + phase1 (1), + phase2 (2), + phase3 (3), + phase1-2 (4), + phase2-3 (5), + phase3-1 (6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The phase/s associated with this outlet. + + For single phase devices, this object will always + return phase1(1). + + For 3-phase devices, this object will return phase1 (1), + phase2 (2), or phase3 (3) for outlets tied to a single + phase. For outlets tied to two phases, this object will + return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for + phases 2 and 3, and phase3-1 (6) for phases 3 and 1." + ::= { rPDUOutletControlEntry 3 } + +rPDUOutletControlOutletCommand OBJECT-TYPE + SYNTAX INTEGER { + immediateOn (1), + immediateOff (2), + immediateReboot (3), + delayedOn (4), + delayedOff (5), + delayedReboot (6), + cancelPendingCommand (7) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this variable will return the outlet state. If + the outlet is on, the immediateOn (1) value will be returned. + If the outlet is off, the immediateOff (2) value will be + returned. + + + Setting this variable to immediateOn (1) will immediately turn + the outlet on. + + Setting this variable to immediateOff (2) will immediately turn + the outlet off. + + Setting this variable to immediateReboot (3) will immediately + reboot the outlet. + + Setting this variable to delayedOn (4) will turn the outlet on + after the rPDUOutletConfigPowerOnTime OID time has elapsed. + + Setting this variable to delayedOff (5) will turn the outlet off + after the rPDUOutletConfigPowerOffTime OID time has elapsed. + + Setting this variable to delayedReboot (6) will cause the + Switched Rack PDU to perform a delayedOff command, wait the + rPDUOutletConfigRebootDuration OID time, and then perform a + delayedOn command. + + Setting this variable to cancelPendingCommand (7) will cause any + pending command to this outlet to be canceled." + + ::= { rPDUOutletControlEntry 4 } + +rPDUOutletControlOutletBank OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The bank associated with this outlet." + ::= { rPDUOutletControlEntry 5 } + + +-- the rPDUOutletConfig group + +rPDUOutletConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDUOutletConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of individual outlets. The number of + entries is contained in the rPDUOutletDevNumCntrlOutlets OID." + ::= { rPDUOutletConfig 1 } + +rPDUOutletConfigEntry OBJECT-TYPE + SYNTAX RPDUOutletConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlet to configure." + INDEX { rPDUOutletConfigIndex} + ::= { rPDUOutletConfigTable 1 } + +RPDUOutletConfigEntry ::= + SEQUENCE { + rPDUOutletConfigIndex INTEGER, + rPDUOutletConfigOutletName DisplayString, + rPDUOutletConfigOutletPhase INTEGER, + rPDUOutletConfigPowerOnTime INTEGER, + rPDUOutletConfigPowerOffTime INTEGER, + rPDUOutletConfigRebootDuration INTEGER, + rPDUOutletConfigOutletBank INTEGER + } + +rPDUOutletConfigIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { rPDUOutletConfigEntry 1 } + +rPDUOutletConfigOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the outlet. The maximum string size is device dependent. + An error will be returned if the set request exceeds the max size." + ::= { rPDUOutletConfigEntry 2 } + +rPDUOutletConfigOutletPhase OBJECT-TYPE + SYNTAX INTEGER { + phase1 (1), + phase2 (2), + phase3 (3), + phase1-2 (4), + phase2-3 (5), + phase3-1 (6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The phase/s associated with this outlet. + + For single phase devices, this object will always + return phase1(1). + + For 3-phase devices, this object will return phase1 (1), + phase2 (2), or phase3 (3) for outlets tied to a single + phase. For outlets tied to two phases, this object will + return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for + phases 2 and 3, and phase3-1 (6) for phases 3 and 1." + ::= { rPDUOutletConfigEntry 3 } + +rPDUOutletConfigPowerOnTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of time (in seconds) the outlet will delay + powering on at coldstart or when a command that requires + a turn-on delay is issued. + + Allowed values are: + + -1 - never power on. + 0 - power on immediately. + 1 to 7200 - power on up to 7200 seconds after being + commanded." + ::= { rPDUOutletConfigEntry 4 } + +rPDUOutletConfigPowerOffTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of time (in seconds) the outlet will delay + powering off when a command that requires + a turn-off delay is issued. + + Allowed values are: + + -1 - never power off. + 0 - power off immediately. + 1 to 7200 - power off up to 7200 seconds after being + commanded." + ::= { rPDUOutletConfigEntry 5 } + +rPDUOutletConfigRebootDuration OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "During a reboot sequence, power is turned off and then + back on. This OID defines the amount of time to wait, + in seconds, after turning the power off, at the start + of the sequence, before turning power back on, at the + end of the reboot sequence. + + Allowed range is any value between 5 and 60 seconds (1 minute)." + ::= { rPDUOutletConfigEntry 6 } + +rPDUOutletConfigOutletBank OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The bank associated with this outlet." + ::= { rPDUOutletConfigEntry 7 } + +-- Monitored Outlets table + +rPDUOutletConfigMonitoredTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The size of the Outlet Config Monitored Table" + ::= { rPDUOutletConfig 2 } + + +rPDUOutletConfigMonitoredTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDUOutletConfigMonitoredEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting/setting of outlet thresholds of an Outlet Monitored Rack PDU." + ::= { rPDUOutletConfig 3 } + +rPDUOutletConfigMonitoredEntry OBJECT-TYPE + SYNTAX RPDUOutletConfigMonitoredEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This gives access to Monitored Outlet entries" + INDEX { rPDUOutletConfigMonitoredIndex } + ::= { rPDUOutletConfigMonitoredTable 1 } + +RPDUOutletConfigMonitoredEntry ::= + SEQUENCE { + rPDUOutletConfigMonitoredIndex INTEGER, + rPDUOutletConfigMonitoredName DisplayString, + rPDUOutletConfigMonitoredNumber INTEGER, + rPDUOutletConfigMonitoredLowLoadThreshold INTEGER, + rPDUOutletConfigMonitoredNearOverloadThreshold INTEGER, + rPDUOutletConfigMonitoredOverloadThreshold INTEGER + } + +rPDUOutletConfigMonitoredIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the RACK PDU Phase entry." + ::= { rPDUOutletConfigMonitoredEntry 1 } + +rPDUOutletConfigMonitoredName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the Monitored Outlet. The maximum string size is device dependent. + An error will be returned if the set request exceeds the max size." + ::= { rPDUOutletConfigMonitoredEntry 2 } + +rPDUOutletConfigMonitoredNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The outlet number of an Outlet Monitored RACK PDU." + ::= { rPDUOutletConfigMonitoredEntry 3 } + + +rPDUOutletConfigMonitoredLowLoadThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the power consumption of + the load is nearing a low consumption condition. It is + represented in Amps. A warning will be issued when the + load is less than the threshold value. + + A threshold value of 0 Amps effectively disables this + warning. + + Maximum value must be less than the value returned + by the rPDUOutletConfigMonitoredNearOverloadThreshold OID. + + 0 will be returned if the unit is not Outlet Monitored Rack PDU." + ::= { rPDUOutletConfigMonitoredEntry 4 } + +rPDUOutletConfigMonitoredNearOverloadThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the power consumption of + the load is nearing an overload condition. It is + represented in Amps. A warning will be issued when the + load is greater than or equal to the threshold value. + + Minimum value must be greater than the value returned by + the rPDUOutletConfigMonitoredLowLoadThreshold OID. + + Maximum value must be less than or equal to the value + returned by the rPDUOutletConfigMonitoredOverloadThreshold OID. + + 0 will be returned if the unit is not Outlet Monitored Rack PDU." + ::= { rPDUOutletConfigMonitoredEntry 5 } + +rPDUOutletConfigMonitoredOverloadThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the power consumption of + the load has entered an overload condition. It is + represented in Amps. A warning will be issued when the + load is greater than or equal to the threshold value. + + Minimum value must be greater than or equal to the value + returned by the rPDUOutletConfigMonitoredNearOverloadThreshold OID. + + Maximum value must be less than or equal to the value + returned by the rPDULoadDevMaxOutletLoad OID. + + 0 will be returned if the unit is not Outlet Monitored Rack PDU." + ::= { rPDUOutletConfigMonitoredEntry 6 } + + + + +-- the rPDUOutletStatus group + +rPDUOutletStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDUOutletStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting of status of individual outlets. The number of + entries is contained in the rPDUOutletDevNumCntrlOutlets OID or + rPDUOutletDevMonitoredOutlets OID." + ::= { rPDUOutletStatus 1 } + +rPDUOutletStatusEntry OBJECT-TYPE + SYNTAX RPDUOutletStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlet to gather status from." + INDEX { rPDUOutletStatusIndex} + ::= { rPDUOutletStatusTable 1 } + +RPDUOutletStatusEntry ::= + SEQUENCE { + rPDUOutletStatusIndex INTEGER, + rPDUOutletStatusOutletName DisplayString, + rPDUOutletStatusOutletPhase INTEGER, + rPDUOutletStatusOutletState INTEGER, + rPDUOutletStatusCommandPending INTEGER, + rPDUOutletStatusOutletBank INTEGER, + rPDUOutletStatusLoad Gauge + } + +rPDUOutletStatusIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { rPDUOutletStatusEntry 1 } + +rPDUOutletStatusOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the outlet. The maximum string size is device dependent. + This OID is provided for informational purposes only." + ::= { rPDUOutletStatusEntry 2 } + +rPDUOutletStatusOutletPhase OBJECT-TYPE + SYNTAX INTEGER { + phase1 (1), + phase2 (2), + phase3 (3), + phase1-2 (4), + phase2-3 (5), + phase3-1 (6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The phase/s associated with this outlet. + + For single phase devices, this object will always + return phase1(1). + + For 3-phase devices, this object will return phase1 (1), + phase2 (2), or phase3 (3) for outlets tied to a single + phase. For outlets tied to two phases, this object will + return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for + phases 2 and 3, and phase3-1 (6) for phases 3 and 1." + ::= { rPDUOutletStatusEntry 3 } + +rPDUOutletStatusOutletState OBJECT-TYPE + SYNTAX INTEGER { + outletStatusOn (1), + outletStatusOff (2) + } + + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the outlet state. If + the outlet is on, the outletStatusOn (1) value will be returned. + If the outlet is off, the outletStatusOff (2) value will be + returned." + ::= { rPDUOutletStatusEntry 4 } + +rPDUOutletStatusCommandPending OBJECT-TYPE + SYNTAX INTEGER { + outletStatusCommandPending (1), + outletStatusNoCommandPending (2) + } + + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the command pending + state of the outlet. If a command is pending on the + outlet, the outletStatusCommandPending (1) value + will be returned. If there is not a command pending + on the outlet, the outletStatusNoCommandPending (2) + will be returned." + ::= { rPDUOutletStatusEntry 5 } + +rPDUOutletStatusOutletBank OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The bank associated with this outlet." + ::= { rPDUOutletStatusEntry 6 } + +rPDUOutletStatusLoad OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the measured Outlet load for + an Outlet Monitored Rack PDU in tenths of Amps. For other + models this OID is not supported." + ::= { rPDUOutletStatusEntry 7 } + + +-- the rPDUOutletBank group + +rPDUOutletBankTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDUOutletBankEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for management of outlets on a per bank basis." + ::= { rPDUOutletBank 1 } + +rPDUOutletBankEntry OBJECT-TYPE + SYNTAX RPDUOutletBankEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The bank to manage." + INDEX { rPDUOutletBankIndex} + ::= { rPDUOutletBankTable 1 } + +RPDUOutletBankEntry ::= + SEQUENCE { + rPDUOutletBankIndex INTEGER, + rPDUOutletBankOverloadRestriction INTEGER + } + +rPDUOutletBankIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Switched Rack PDU bank entry." + ::= { rPDUOutletBankEntry 1 } + +rPDUOutletBankOverloadRestriction OBJECT-TYPE + SYNTAX INTEGER { + alwaysAllowTurnON (1), + restrictOnNearOverload (2), + restrictOnOverload (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This OID controls the behavior of a Switched Rack PDU + bank when an overload condition is possible and + additional outlets are requested to be turned on. + + Setting this OID to alwaysAllowTurnON (1) will always allow + the outlets on the corresponding bank to turn on. + + Setting this OID to restrictOnNearOverload (2) will not allow + outlets on the corresponding bank to turn on if the + rPDULoadBankConfigNearOverloadThreshold OID is exceeded. + + Setting this OID to restrictOnOverload (3) will not allow + outlets on the corresponding bank to turn on if the + rPDULoadBankConfigOverloadThreshold OID is exceeded." + ::= { rPDUOutletBankEntry 2 } + +-- the rPDUPowerSupplyDevice group + +rPDUPowerSupply1Status OBJECT-TYPE + SYNTAX INTEGER { + powerSupplyOneOk (1), + powerSupplyOneFailed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return powerSupply1Ok(1) if power + supply 1 is functioning normally. If not functioning normally, + this OID will return powerSupply1Failed(2)." + ::= { rPDUPowerSupplyDevice 1 } + +rPDUPowerSupply2Status OBJECT-TYPE + SYNTAX INTEGER { + powerSupplyTwoOk (1), + powerSupplyTwoFailed (2), + powerSupplyTwoNotPresent (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return powerSupply2Ok(1) if power + supply 2 is functioning normally. If not functioning normally, + this OID will return powerSupply2Failed(2). + + Metered Rack PDUs do not have a redundant powersupply." + + ::= { rPDUPowerSupplyDevice 2 } + + + +rPDUPowerSupplyAlarm OBJECT-TYPE + SYNTAX INTEGER { + allAvailablePowerSuppliesOK (1), + powerSupplyOneFailed (2), + powerSupplyTwoFailed (3), + powerSupplyOneandTwoFailed (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return powerSupply Alarm" + ::= { rPDUPowerSupplyDevice 3 } + +-- the rPDUStatus group + +rPDUStatusBankTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The size of the Status Bank Table" + ::= { rPDUStatus 1 } + + +rPDUStatusBankTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDUStatusBankEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting of status of each Rack PDU Bank" + ::= { rPDUStatus 2 } + +rPDUStatusBankEntry OBJECT-TYPE + SYNTAX RPDUStatusBankEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This gives access to Bank entries" + INDEX { rPDUStatusBankIndex } + ::= { rPDUStatusBankTable 1 } + +RPDUStatusBankEntry ::= + SEQUENCE { + rPDUStatusBankIndex INTEGER, + rPDUStatusBankNumber INTEGER, + rPDUStatusBankState INTEGER + } + +rPDUStatusBankIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the RACK PDU Bank entry." + ::= { rPDUStatusBankEntry 1 } + +rPDUStatusBankNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the bank number." + ::= { rPDUStatusBankEntry 2 } + +rPDUStatusBankState OBJECT-TYPE + SYNTAX INTEGER { + bankLoadNormal (1), + bankLoadLow (2), + bankLoadNearOverload (3), + bankLoadOverload (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the bank load state. + + bankLoadNormal(1) indicates that the bank is + operating properly within the rPDULoadBankConfigLowLoadThreshold + and rPDULoadBankConfigNearOverloadThreshold OID values. + + bankLoadLow(2) indicates that the bank load has + dropped below the rPDULoadBankConfigLowLoadThreshold OID value. + An SNMP trap will occur when this state is entered or cleared. + + bankLoadNearOverload(3) indicates that the bank load + is greater than or equal to the + rPDULoadBankConfigNearOverloadThreshold OID value. + An SNMP trap will occur when this state is entered or cleared. + + bankLoadOverload(4) indicates that the bank load is + greater than or equal to the rPDULoadBankConfigOverloadThreshold + OID value. + An SNMP trap will occur when this state is entered or cleared." + ::= { rPDUStatusBankEntry 3 } + +-- Phase status table + +rPDUStatusPhaseTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The size of the Status Phase Table" + ::= { rPDUStatus 3 } + + +rPDUStatusPhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDUStatusPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting of status of each Rack PDU Phase" + ::= { rPDUStatus 4 } + +rPDUStatusPhaseEntry OBJECT-TYPE + SYNTAX RPDUStatusPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This gives access to Phase entries" + INDEX { rPDUStatusPhaseIndex } + ::= { rPDUStatusPhaseTable 1 } + +RPDUStatusPhaseEntry ::= + SEQUENCE { + rPDUStatusPhaseIndex INTEGER, + rPDUStatusPhaseNumber INTEGER, + rPDUStatusPhaseState INTEGER + } + +rPDUStatusPhaseIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the RACK PDU Phase entry." + ::= { rPDUStatusPhaseEntry 1 } + +rPDUStatusPhaseNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the phase number." + ::= { rPDUStatusPhaseEntry 2 } + +rPDUStatusPhaseState OBJECT-TYPE + SYNTAX INTEGER { + phaseLoadNormal (1), + phaseLoadLow (2), + phaseLoadNearOverload (3), + phaseLoadOverload (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the Phase load state. + + phaseLoadNormal(1) indicates that the Phase is + operating properly within the rPDULoadPhaseConfigLowLoadThreshold + and rPDULoadPhaseConfigNearOverloadThreshold OID values. + + phaseLoadLow(2) indicates that the Phase load has + dropped below the rPDULoadPhaseConfigLowLoadThreshold OID value. + An SNMP trap will occur when this state is entered or cleared. + + phaseLoadNearOverload(3) indicates that the Phase load + is greater than or equal to the + rPDULoadPhaseConfigNearOverloadThreshold OID value. + An SNMP trap will occur when this state is entered or cleared. + + phaseLoadOverload(4) indicates that the Phase load is + greater than or equal to the rPDULoadPhaseConfigOverloadThreshold + OID value. + An SNMP trap will occur when this state is entered or cleared." + ::= { rPDUStatusPhaseEntry 3 } + +-- Outlet status table + +rPDUStatusOutletTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The size of the Status Outlet Table" + ::= { rPDUStatus 5 } + + +rPDUStatusOutletTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDUStatusOutletEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU." + ::= { rPDUStatus 6 } + +rPDUStatusOutletEntry OBJECT-TYPE + SYNTAX RPDUStatusOutletEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This gives access to Outlet entries" + INDEX { rPDUStatusOutletIndex } + ::= { rPDUStatusOutletTable 1 } + +RPDUStatusOutletEntry ::= + SEQUENCE { + rPDUStatusOutletIndex INTEGER, + rPDUStatusOutletNumber INTEGER, + rPDUStatusOutletState INTEGER + } + +rPDUStatusOutletIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the RACK PDU Outlet entry." + ::= { rPDUStatusOutletEntry 1 } + +rPDUStatusOutletNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the Outlet number." + ::= { rPDUStatusOutletEntry 2 } + +rPDUStatusOutletState OBJECT-TYPE + SYNTAX INTEGER { + outletLoadNormal (1), + outletLoadLow (2), + outletLoadNearOverload (3), + outletLoadOverload (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the Outlet load state. + + outletLoadNormal(1) indicates that the Outlet is + operating properly within the rPDUOutletConfigMonitoredLowLoadThreshold + and rPDUOutletConfigMonitoredNearOverloadThreshold OID values. + + outletLoadLow(2) indicates that the Outlet load has + dropped below the rPDUOutletConfigMonitoredLowLoadThreshold OID value. + An SNMP trap will occur when this state is entered or cleared. + + outletLoadNearOverload(3) indicates that the Outlet load + is greater than or equal to the + rPDUOutletConfigMonitoredNearOverloadThreshold OID value. + An SNMP trap will occur when this state is entered or cleared. + + outletLoadOverload(4) indicates that the Outlet load is + greater than or equal to the rPDUOutletConfigMonitoredOverloadThreshold + OID value. + An SNMP trap will occur when this state is entered or cleared." + ::= { rPDUStatusOutletEntry 3 } + +-- Common rPDU2 values + +Rpdu2OutletPhaseLayoutType ::= INTEGER { + seqPhase1ToNeutral (1), + seqPhase2ToNeutral (2), + seqPhase3ToNeutral (3), + seqPhase1ToPhase2 (4), + seqPhase2ToPhase3 (5), + seqPhase3ToPhase1 (6) + } + +-- rPDU2 Ident Table + +rPDU2IdentTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of Rack PDUs" + ::= { rPDU2 1 } + +rPDU2IdentTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2IdentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU identification data" + ::= { rPDU2 2 } + +rPDU2IdentEntry OBJECT-TYPE + SYNTAX RPDU2IdentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Identification data from Rack PDU being queried" + INDEX { rPDU2IdentIndex } + ::= { rPDU2IdentTable 1 } + +RPDU2IdentEntry ::= + SEQUENCE { + rPDU2IdentIndex INTEGER, + rPDU2IdentModule INTEGER, + rPDU2IdentName DisplayString, + rPDU2IdentLocation DisplayString, + rPDU2IdentHardwareRev DisplayString, + rPDU2IdentFirmwareRev DisplayString, + rPDU2IdentDateOfManufacture DisplayString, + rPDU2IdentModelNumber DisplayString, + rPDU2IdentSerialNumber DisplayString, + rPDU2IdentContact DisplayString + } + +rPDU2IdentIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU identification table + entry" + ::= { rPDU2IdentEntry 1 } + +rPDU2IdentModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2IdentEntry 2 } + +rPDU2IdentName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A user-defined string identifying the Rack PDU" + ::= { rPDU2IdentEntry 3 } + +rPDU2IdentLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A user-defined string identifying the location + of the Rack PDU" + ::= { rPDU2IdentEntry 4 } + +rPDU2IdentHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Rack PDU hardware version" + ::= { rPDU2IdentEntry 5 } + +rPDU2IdentFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Rack PDU firware version" + ::= { rPDU2IdentEntry 6 } + +rPDU2IdentDateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date the Rack PDU was manufactured + in mm/dd/yyyy format" + ::= { rPDU2IdentEntry 7 } + +rPDU2IdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Rack PDU model number" + ::= { rPDU2IdentEntry 8 } + +rPDU2IdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Rack PDU serial number" + ::= { rPDU2IdentEntry 9 } + +rPDU2IdentContact OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A user-defined string identifying the + person to contact regarding the Rack PDU" + ::= { rPDU2IdentEntry 10 } + +-- rPDU2 Device Data + +rPDU2DeviceTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of Rack PDUs" + ::= { rPDU2 3 } + +rPDU2Device OBJECT IDENTIFIER ::= { rPDU2 4 } + +-- rPDU2 Device Config + +rPDU2DeviceConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2DeviceConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU configuration data" + ::= { rPDU2Device 1 } + +rPDU2DeviceConfigEntry OBJECT-TYPE + SYNTAX RPDU2DeviceConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Configuration data from Rack PDU being queried" + INDEX { rPDU2DeviceConfigIndex } + ::= { rPDU2DeviceConfigTable 1 } + +RPDU2DeviceConfigEntry ::= + SEQUENCE { + rPDU2DeviceConfigIndex INTEGER, + rPDU2DeviceConfigModule INTEGER, + rPDU2DeviceConfigName DisplayString, + rPDU2DeviceConfigLocation DisplayString, + rPDU2DeviceConfigDisplayOrientation INTEGER, + rPDU2DeviceConfigColdstartDelay INTEGER, + rPDU2DeviceConfigLowLoadPowerThreshold INTEGER, + rPDU2DeviceConfigNearOverloadPowerThreshold INTEGER, + rPDU2DeviceConfigOverloadPowerThreshold INTEGER, + rPDU2DeviceConfigDevicePeakPowerReset INTEGER, + rPDU2DeviceConfigDeviceEnergyReset INTEGER, + rPDU2DeviceConfigOutletsEnergyReset INTEGER, + rPDU2DeviceConfigOutletsPeakLoadReset INTEGER + } + +rPDU2DeviceConfigIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU table entry" + ::= { rPDU2DeviceConfigEntry 1 } + +rPDU2DeviceConfigModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2DeviceConfigEntry 2 } + +rPDU2DeviceConfigName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A user-defined string identifying the Rack PDU" + ::= { rPDU2DeviceConfigEntry 3 } + +rPDU2DeviceConfigLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A user-defined string identifying the location + of the Rack PDU" + ::= { rPDU2DeviceConfigEntry 4 } + +rPDU2DeviceConfigDisplayOrientation OBJECT-TYPE + SYNTAX INTEGER { + displayNormal (1), + displayReverse (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Indicates the intended physical orientation + of the seven segment display + + displayNormal(1) indicates normal orientation + displayReverse(2) indicates upside down orientation" + ::= { rPDU2DeviceConfigEntry 5 } + +rPDU2DeviceConfigColdstartDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of delay, measured in seconds, between + when power is provided to the Rack PDU and when + the Rack PDU provides basic master power to the + outlets. + Allowed values are: + -1 - never apply power automatically. + 0 - apply power immediately. + 1 to 300 - delay up to 300 seconds (5 minutes)." + ::= { rPDU2DeviceConfigEntry 6 } + +rPDU2DeviceConfigLowLoadPowerThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "User-defined low power draw alarm threshold, + measured in tenths of kilowatts" + ::= { rPDU2DeviceConfigEntry 7 } + +rPDU2DeviceConfigNearOverloadPowerThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "User-defined near power overload threshold, + measured in tenths of kilowatts" + ::= { rPDU2DeviceConfigEntry 8 } + +rPDU2DeviceConfigOverloadPowerThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "User-defined power overload threshold, + measured in tenths of kilowatts" + ::= { rPDU2DeviceConfigEntry 9 } + +rPDU2DeviceConfigDevicePeakPowerReset OBJECT-TYPE + SYNTAX INTEGER { + noOperation (1), + reset (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset (2) will cause the existing peak power value + to be replaced by the current load power value. + + Getting this OID will do nothing and return the noOperation(1) value." + ::= { rPDU2DeviceConfigEntry 10 } + +rPDU2DeviceConfigDeviceEnergyReset OBJECT-TYPE + SYNTAX INTEGER { + noOperation (1), + reset (2), + notSupported (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset (2) will cause the device energy meter value + to be reset to zero. + + Getting this OID in models that support this feature will do nothing + and return the noOperation(1) value. + + Models that do not support this feature will respond to this OID + with a value of notSupported (3). Attempts to set this OID + in these models will fail." + ::= { rPDU2DeviceConfigEntry 11 } + +rPDU2DeviceConfigOutletsEnergyReset OBJECT-TYPE + SYNTAX INTEGER { + noOperation (1), + reset (2), + notSupported (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset (2) will cause the all outlet energy meter values + to be reset to zero. + + Getting this OID will do nothing and return the noOperation(1) value. + + Models that do not support this feature will respond to this OID + with a value of notSupported (3). Attempts to set this OID + in these models will fail." + ::= { rPDU2DeviceConfigEntry 12 } + +rPDU2DeviceConfigOutletsPeakLoadReset OBJECT-TYPE + SYNTAX INTEGER { + noOperation (1), + reset (2), + notSupported (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset (2) will cause the all outlet peak load values + to be reset to zero. + + Getting this OID will do nothing and return the noOperation(1) value. + + Models that do not support this feature will respond to this OID + with a value of notSupported (3). Attempts to set this OID + in these models will fail." + ::= { rPDU2DeviceConfigEntry 13 } + +-- rPDU2 Device Properties + +rPDU2DevicePropertiesTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2DevicePropertiesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU properties" + ::= { rPDU2Device 2 } + +rPDU2DevicePropertiesEntry OBJECT-TYPE + SYNTAX RPDU2DevicePropertiesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Properties of the Rack PDU being queried" + INDEX { rPDU2DevicePropertiesIndex } + ::= { rPDU2DevicePropertiesTable 1 } + +RPDU2DevicePropertiesEntry ::= + SEQUENCE { + rPDU2DevicePropertiesIndex INTEGER, + rPDU2DevicePropertiesModule INTEGER, + rPDU2DevicePropertiesName DisplayString, + rPDU2DevicePropertiesNumOutlets INTEGER, + rPDU2DevicePropertiesNumSwitchedOutlets INTEGER, + rPDU2DevicePropertiesNumMeteredOutlets INTEGER, + rPDU2DevicePropertiesNumPhases INTEGER, + rPDU2DevicePropertiesNumMeteredBanks INTEGER, + rPDU2DevicePropertiesMaxCurrentRating INTEGER, + rPDU2DevicePropertiesOrientation INTEGER, + rPDU2DevicePropertiesOutletLayout INTEGER, + rPDU2DevicePropertiesMaxPhaseCurrentRating INTEGER + } + +rPDU2DevicePropertiesIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU properties table entry" + ::= { rPDU2DevicePropertiesEntry 1 } + +rPDU2DevicePropertiesModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2DevicePropertiesEntry 2 } + +rPDU2DevicePropertiesName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A user-defined string identifying the Rack PDU" + ::= { rPDU2DevicePropertiesEntry 3 } + +rPDU2DevicePropertiesNumOutlets OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of outlets on the Rack PDU" + ::= { rPDU2DevicePropertiesEntry 4 } + +rPDU2DevicePropertiesNumSwitchedOutlets OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of switched outlets on the Rack PDU" + ::= { rPDU2DevicePropertiesEntry 5 } + +rPDU2DevicePropertiesNumMeteredOutlets OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of metered outlets on the Rack PDU" + ::= { rPDU2DevicePropertiesEntry 6 } + +rPDU2DevicePropertiesNumPhases OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of phases present in the Rack PDU" + ::= { rPDU2DevicePropertiesEntry 7 } + +rPDU2DevicePropertiesNumMeteredBanks OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of metered banks present in the Rack PDU" + ::= { rPDU2DevicePropertiesEntry 8 } + +rPDU2DevicePropertiesMaxCurrentRating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum current rating, measured in Amps, for + the Rack PDU" + ::= { rPDU2DevicePropertiesEntry 9 } + +rPDU2DevicePropertiesOrientation OBJECT-TYPE + SYNTAX INTEGER { + horizontal (1), + vertical (2), + verticalISXv2 (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Rack PDU orientation" + ::= { rPDU2DevicePropertiesEntry 10 } + +rPDU2DevicePropertiesOutletLayout OBJECT-TYPE + SYNTAX INTEGER { + seqPhaseToNeutral (1), + seqPhaseToPhase (2), + seqPhToNeu21PhToPh (3), + seqPhToPhGrouped (4), + seqPhToNGrouped (5), + seqPToN1516PToPGrouped (6), + seqPhToPh2xGrouped (7), + seqPhToN2xGrouped (8), + seqNotApplicable (9), + seqPhToNPhToPhPhToN (10) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return outlet layout for the device. + + seqPhaseToNeutral(1) indicates outlet layout as follows: + 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... + or for single phase SKUs, all outlets 1-N + + seqPhaseToPhase(2) indicates outlet layout as follows: + 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,... + + seqPhToNeu21PhToPh(3) indicates outlet layout as follows: + 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,... + + seqPhToPhGrouped(4) indicates outlet layout as follows: + For AP8xxx SKU's Group 1:1-2, Group 2:2-3, Group 3:3-1. + + seqPhToNGrouped(5) indicates outlet layout as follows: + This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N. + + seqPToN1516PToPGrouped(6) indicates outlet layout as follows: + This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2, + Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1. + + seqPhToPh2xGrouped(7) indicates outlet layout as follows: + This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3, + Group 4:2-3, Group 5:3-1, Group 6:3-1. + + seqPhToN2xGrouped(8) indicates outlet layout as follows: + This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N, + Group 4:2-N, Group 5:3-N, Group 6:3-N. + + seqNotApplicable(9): + Outlet layout does not affect any of the user interfaces for + AP88XX SKUs. These SKUs may report seqNotApplicable(9) if there is + not an exact outlet layout match available. + + seqPhToNPhToPhPhToN(10) indicates outlet layout as follows: + Group 1:1-N, Group 2:1-2, Group 3:2-N." + ::= { rPDU2DevicePropertiesEntry 11 } + +rPDU2DevicePropertiesMaxPhaseCurrentRating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum current rating, measured in Amps, for + the Rack PDU" + ::= { rPDU2DevicePropertiesEntry 12 } + +-- rPDU2 Device Status + +rPDU2DeviceStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2DeviceStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU status information" + ::= { rPDU2Device 3 } + +rPDU2DeviceStatusEntry OBJECT-TYPE + SYNTAX RPDU2DeviceStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Status information from the Rack PDU being queried" + INDEX { rPDU2DeviceStatusIndex } + ::= { rPDU2DeviceStatusTable 1 } + +RPDU2DeviceStatusEntry ::= + SEQUENCE { + rPDU2DeviceStatusIndex INTEGER, + rPDU2DeviceStatusModule INTEGER, + rPDU2DeviceStatusName DisplayString, + rPDU2DeviceStatusLoadState INTEGER, + rPDU2DeviceStatusPower INTEGER, + rPDU2DeviceStatusPeakPower INTEGER, + rPDU2DeviceStatusPeakPowerTimestamp DisplayString, + rPDU2DeviceStatusPeakPowerStartTime DisplayString, + rPDU2DeviceStatusEnergy INTEGER, + rPDU2DeviceStatusEnergyStartTime DisplayString, + rPDU2DeviceStatusCommandPending INTEGER, + rPDU2DeviceStatusPowerSupplyAlarm INTEGER, + rPDU2DeviceStatusPowerSupply1Status INTEGER, + rPDU2DeviceStatusPowerSupply2Status INTEGER, + rPDU2DeviceStatusOutletsEnergyStartTime DisplayString, + rPDU2DeviceStatusApparentPower INTEGER, + rPDU2DeviceStatusPowerFactor INTEGER, + rPDU2DeviceStatusNPSType INTEGER + } + +rPDU2DeviceStatusIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU status table entry" + ::= { rPDU2DeviceStatusEntry 1 } + +rPDU2DeviceStatusModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2DeviceStatusEntry 2 } + +rPDU2DeviceStatusName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A user-defined string identifying the Rack PDU" + ::= { rPDU2DeviceStatusEntry 3 } + +rPDU2DeviceStatusLoadState OBJECT-TYPE + SYNTAX INTEGER { + lowLoad (1), + normal (2), + nearOverload (3), + overload (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the present load status of the Rack PDU" + ::= { rPDU2DeviceStatusEntry 4 } + +rPDU2DeviceStatusPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The power consumption of the Rack PDU load in hundredths of kilowatts" + ::= { rPDU2DeviceStatusEntry 5 } + +rPDU2DeviceStatusPeakPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The peak power consumption of the Rack PDU load in hundredths of kilowatts" + ::= { rPDU2DeviceStatusEntry 6 } + +rPDU2DeviceStatusPeakPowerTimestamp OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the date and time that peak power consumption occurred" + ::= { rPDU2DeviceStatusEntry 7 } + +rPDU2DeviceStatusPeakPowerStartTime OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the date and time of the last device peak power reset" + ::= { rPDU2DeviceStatusEntry 8 } + +rPDU2DeviceStatusEnergy OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A user resettable energy meter measuring Rack PDU load + energy consumption in tenths of kilowatt-hours" + ::= { rPDU2DeviceStatusEntry 9 } + +rPDU2DeviceStatusEnergyStartTime OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the date and time of the last device energy + meter reset" + ::= { rPDU2DeviceStatusEntry 10 } + + +rPDU2DeviceStatusCommandPending OBJECT-TYPE + SYNTAX INTEGER { + commandPending (1), + noCommandPending (2), + commandPendingUnknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not the device + is processing a pending command. If + the commandPendingUnknown (3) value is + returned, all devices powered by the + Rack PDU should be shut down. The + Rack PDU's power should then be cycled + to clear this condition." + ::= { rPDU2DeviceStatusEntry 11 } + +rPDU2DeviceStatusPowerSupplyAlarm OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates a power supply alarm is active when value + equals alarm (2)" + ::= { rPDU2DeviceStatusEntry 12 } + +rPDU2DeviceStatusPowerSupply1Status OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2), + notInstalled (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not an alarm is active in Power + Supply 1" + ::= { rPDU2DeviceStatusEntry 13 } + +rPDU2DeviceStatusPowerSupply2Status OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2), + notInstalled (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not an alarm is active in Power + Supply 2" + ::= { rPDU2DeviceStatusEntry 14 } + +rPDU2DeviceStatusOutletsEnergyStartTime OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the date and time of the last outlets energy + meter reset" + ::= { rPDU2DeviceStatusEntry 15 } + +rPDU2DeviceStatusApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The apparent power consumption of the Rack PDU load in hundredths of kiloVoltAmps (kVA)" + ::= { rPDU2DeviceStatusEntry 16 } + +rPDU2DeviceStatusPowerFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The power factor of the Rack PDU load in hundredths" + ::= { rPDU2DeviceStatusEntry 17 } + +rPDU2DeviceStatusNPSType OBJECT-TYPE + SYNTAX INTEGER { + notNPS (1), + host (2), + guest (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The device NPS status: + notNPS (1) indicates the Rack PDU is not in an NPS group. + host (2) indicates the Rack PDU has been designated as a host in an NPS group. + Only one Rack PDU in an NPS group is allowed to be the host. + guest (3) indicates the Rack PDU has been designated as a guest in an NPS group." + ::= { rPDU2DeviceStatusEntry 18 } + +-- rPDU2 Device Control + +rPDU2DeviceControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2DeviceControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU control data" + ::= { rPDU2Device 4 } + +rPDU2DeviceControlEntry OBJECT-TYPE + SYNTAX RPDU2DeviceControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Control data from Rack PDU being queried" + INDEX { rPDU2DeviceControlIndex } + ::= { rPDU2DeviceControlTable 1 } + +RPDU2DeviceControlEntry ::= + SEQUENCE { + rPDU2DeviceControlIndex INTEGER, + rPDU2DeviceControlModule INTEGER, + rPDU2DeviceControlName DisplayString, + rPDU2DeviceControlCommand INTEGER + } + +rPDU2DeviceControlIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU control table entry" + ::= { rPDU2DeviceControlEntry 1 } + +rPDU2DeviceControlModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2DeviceControlEntry 2 } + +rPDU2DeviceControlName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A user-defined string identifying the Rack PDU" + ::= { rPDU2DeviceControlEntry 3 } + +rPDU2DeviceControlCommand OBJECT-TYPE + SYNTAX INTEGER { + immediateAllOn (1), + delayedAllOn (2), + immediateAllOff (3), + immediateAllReboot (4), + delayedAllReboot (5), + noCommandAll (6), + delayedAllOff (7), + cancelAllPendingCommands (8) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to immediateAllOn (1) will turn all outlets + on immediately. + + Setting this OID to delayedAllOn (2) will turn all outlets on as + defined by each outlet's rPDU2OutletSwitchedConfigPowerOnTime + OID value. + + Setting this OID to immediateAllOff (3) will turn all outlets + off immediately. + + Setting this OID to immediateAllReboot (4) will cause an immediateAllOff + command to be performed. Once all outlets are off, the + Switched Rack PDU will then delay the + rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform an + immediateAllOn command. + + Setting this OID to delayedAllReboot (5) will cause a + delayedAllOff command to be performed. Once all outlets are off, + the Switched Rack PDU will then delay the largest + rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform a + delayedAllOn command. + + Setting this OID to noCommandAll (6) will have no effect. + + Setting this OID to delayedAllOff (7) will turn all outlets off + as defined by each outlet's rPDU2OutletSwitchedConfigPowerOffTime + OID value. + + Setting this OID to cancelAllPendingCommands (8) will cause all pending + commands on the Switched Rack PDU to be cancelled. + + Getting this OID will return the noCommandAll (6) + value." + ::= { rPDU2DeviceControlEntry 4 } + +-- rPDU2 Phase Data + +rPDU2PhaseTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of connected Rack PDU phases" + ::= { rPDU2 5} + +rPDU2Phase OBJECT IDENTIFIER ::= { rPDU2 6 } + +-- rPDU2 Phase Config + +rPDU2PhaseConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2PhaseConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU phase configuration data" + ::= { rPDU2Phase 1 } + +rPDU2PhaseConfigEntry OBJECT-TYPE + SYNTAX RPDU2PhaseConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Configuration data from currently queried Rack + PDU phase" + INDEX { rPDU2PhaseConfigIndex } + ::= { rPDU2PhaseConfigTable 1 } + +RPDU2PhaseConfigEntry ::= + SEQUENCE { + rPDU2PhaseConfigIndex INTEGER, + rPDU2PhaseConfigModule INTEGER, + rPDU2PhaseConfigNumber INTEGER, + rPDU2PhaseConfigOverloadRestriction INTEGER, + rPDU2PhaseConfigLowLoadCurrentThreshold INTEGER, + rPDU2PhaseConfigNearOverloadCurrentThreshold INTEGER, + rPDU2PhaseConfigOverloadCurrentThreshold INTEGER, + rPDU2PhaseConfigPhasePeakCurrentReset INTEGER + } + +rPDU2PhaseConfigIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU phase configuration + table entry" + ::= { rPDU2PhaseConfigEntry 1 } + +rPDU2PhaseConfigModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2PhaseConfigEntry 2 } + +rPDU2PhaseConfigNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The numeric phase ID" + ::= { rPDU2PhaseConfigEntry 3 } + +rPDU2PhaseConfigOverloadRestriction OBJECT-TYPE + SYNTAX INTEGER { + alwaysAllowTurnON (1), + restrictOnNearOverload (2), + restrictOnOverload (3), + notSupported (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This OID controls the behavior of a Switched Rack PDU + phase when an overload condition is possible and + additional outlets are requested to be turned on. + + Setting this OID to alwaysAllowTurnON (1) will always allow + the outlets on the corresponding phase to turn on. + + Setting this OID to restrictOnNearOverload (2) will not allow + outlets on the corresponding phase to turn on if the + rPDULoadConfigNearOverloadThreshold OID is exceeded. + + Setting this OID to restrictOnOverload (3) will not allow + outlets on the corresponding phase to turn on if the + rPDULoadConfigOverloadThreshold OID is exceeded. + + Models that do not support this feature will respond to this OID + with a value of notSupported (4). Attempts to set this OID + in these models will fail." + ::= { rPDU2PhaseConfigEntry 4 } + +rPDU2PhaseConfigLowLoadCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "User-defined low load phase current + threshold in Amps" + ::= { rPDU2PhaseConfigEntry 5 } + +rPDU2PhaseConfigNearOverloadCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "User-defined near phase overload warning + threshold in Amps" + ::= { rPDU2PhaseConfigEntry 6 } + +rPDU2PhaseConfigOverloadCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "User-defined phase overload current + threshold in Amps" + ::= { rPDU2PhaseConfigEntry 7 } + +rPDU2PhaseConfigPhasePeakCurrentReset OBJECT-TYPE + SYNTAX INTEGER { + noOperation (1), + reset (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset (2) will cause the existing peak current value + to be replaced by the present load current value. + + Getting this OID will do nothing and return the noOperation(1) value." + ::= { rPDU2PhaseConfigEntry 8 } + + +-- rPDU2 Phase Properties + +rPDU2PhasePropertiesTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2PhasePropertiesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU phase properties" + ::= { rPDU2Phase 2 } + +rPDU2PhasePropertiesEntry OBJECT-TYPE + SYNTAX RPDU2PhasePropertiesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Properties of the currently queried Rack + PDU phase" + INDEX { rPDU2PhasePropertiesIndex } + ::= { rPDU2PhasePropertiesTable 1 } + +RPDU2PhasePropertiesEntry ::= + SEQUENCE { + rPDU2PhasePropertiesIndex INTEGER, + rPDU2PhasePropertiesModule INTEGER, + rPDU2PhasePropertiesNumber INTEGER + } + +rPDU2PhasePropertiesIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU phase properties + table entry" + ::= { rPDU2PhasePropertiesEntry 1 } + +rPDU2PhasePropertiesModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2PhasePropertiesEntry 2 } + +rPDU2PhasePropertiesNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The numeric phase ID" + ::= { rPDU2PhasePropertiesEntry 3 } + +-- rPDU2 Phase Status + +rPDU2PhaseStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2PhaseStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU phase status data" + ::= { rPDU2Phase 3 } + +rPDU2PhaseStatusEntry OBJECT-TYPE + SYNTAX RPDU2PhaseStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Status data from currently queried Rack PDU + phase" + INDEX { rPDU2PhaseStatusIndex } + ::= { rPDU2PhaseStatusTable 1 } + +RPDU2PhaseStatusEntry ::= + SEQUENCE { + rPDU2PhaseStatusIndex INTEGER, + rPDU2PhaseStatusModule INTEGER, + rPDU2PhaseStatusNumber INTEGER, + rPDU2PhaseStatusLoadState INTEGER, + rPDU2PhaseStatusCurrent INTEGER, + rPDU2PhaseStatusVoltage INTEGER, + rPDU2PhaseStatusPower INTEGER, + rPDU2PhaseStatusApparentPower INTEGER, + rPDU2PhaseStatusPowerFactor INTEGER, + rPDU2PhaseStatusPeakCurrent INTEGER, + rPDU2PhaseStatusPeakCurrentTimestamp DisplayString, + rPDU2PhaseStatusPeakCurrentStartTime DisplayString + } + +rPDU2PhaseStatusIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU phase status table + entry" + ::= { rPDU2PhaseStatusEntry 1 } + +rPDU2PhaseStatusModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2PhaseStatusEntry 2 } + +rPDU2PhaseStatusNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The numeric phase ID" + ::= { rPDU2PhaseStatusEntry 3 } + +rPDU2PhaseStatusLoadState OBJECT-TYPE + SYNTAX INTEGER { + lowLoad (1), + normal (2), + nearOverload (3), + overload (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the present load status of the Rack PDU + phase being queried" + ::= { rPDU2PhaseStatusEntry 4 } + +rPDU2PhaseStatusCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the current draw, in tenths of Amps, of the load + on the Rack PDU phase being queried" + ::= { rPDU2PhaseStatusEntry 5 } + +rPDU2PhaseStatusVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the Voltage, in Volts, of the Rack + PDU phase being queried" + ::= { rPDU2PhaseStatusEntry 6 } + +rPDU2PhaseStatusPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the load power, in hundredths of kilowatts (kW), + consumed on the Rack PDU phase being queried" + ::= { rPDU2PhaseStatusEntry 7 } + +rPDU2PhaseStatusApparentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the load apparent power, in hundredths of kiloVoltAmps (kVA), + consumed on the Rack PDU phase being queried" + ::= { rPDU2PhaseStatusEntry 8 } + +rPDU2PhaseStatusPowerFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the load power factor, in hundredths, + of the Rack PDU phase being queried" + ::= { rPDU2PhaseStatusEntry 9 } + + +rPDU2PhaseStatusPeakCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The peak current of the Rack PDU phase load in tenths of Amps" + ::= { rPDU2PhaseStatusEntry 10 } + +rPDU2PhaseStatusPeakCurrentTimestamp OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the date and time that the peak current occurred" + ::= { rPDU2PhaseStatusEntry 11 } + +rPDU2PhaseStatusPeakCurrentStartTime OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the date and time of the last phase peak current reset" + ::= { rPDU2PhaseStatusEntry 12 } + +-- rPDU2 Bank Data + +rPDU2BankTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of connected Rack PDU banks" + ::= { rPDU2 7} + +rPDU2Bank OBJECT IDENTIFIER ::= { rPDU2 8 } + +-- rPDU2 Bank Config + +rPDU2BankConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2BankConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU bank configuration data" + ::= { rPDU2Bank 1 } + +rPDU2BankConfigEntry OBJECT-TYPE + SYNTAX RPDU2BankConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Configuration data from currently queried + Rack PDU bank" + INDEX { rPDU2BankConfigIndex } + ::= { rPDU2BankConfigTable 1 } + +RPDU2BankConfigEntry ::= + SEQUENCE { + rPDU2BankConfigIndex INTEGER, + rPDU2BankConfigModule INTEGER, + rPDU2BankConfigNumber INTEGER, + rPDU2BankConfigOverloadRestriction INTEGER, + rPDU2BankConfigLowLoadCurrentThreshold INTEGER, + rPDU2BankConfigNearOverloadCurrentThreshold INTEGER, + rPDU2BankConfigOverloadCurrentThreshold INTEGER, + rPDU2BankConfigBankPeakCurrentReset INTEGER + } + +rPDU2BankConfigIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU bank configuration + table entry" + ::= { rPDU2BankConfigEntry 1 } + +rPDU2BankConfigModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2BankConfigEntry 2 } + +rPDU2BankConfigNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The numeric bank ID" + ::= { rPDU2BankConfigEntry 3 } + +rPDU2BankConfigOverloadRestriction OBJECT-TYPE + SYNTAX INTEGER { + alwaysAllowTurnON (1), + restrictOnNearOverload (2), + restrictOnOverload (3), + notSupported (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This OID controls the behavior of a Switched Rack PDU + bank when an overload condition is possible and + additional outlets are requested to be turned on. + + Setting this OID to alwaysAllowTurnON (1) will always allow + the outlets on the corresponding bank to turn on. + + Setting this OID to restrictOnNearOverload (2) will not allow + outlets on the corresponding bank to turn on if the + rPDU2BankConfigNearOverloadCurrentThreshold OID is exceeded. + + Setting this OID to restrictOnOverload (3) will not allow + outlets on the corresponding bank to turn on if the + rPDU2BankConfigOverloadCurrentThreshold OID is exceeded. + + Models that do not support this feature will respond to this OID + with a value of notSupported (4). Attempts to set this OID + in these models will fail." + ::= { rPDU2BankConfigEntry 4 } + +rPDU2BankConfigLowLoadCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "User-defined low load bank current + threshold in Amps" + ::= { rPDU2BankConfigEntry 5 } + +rPDU2BankConfigNearOverloadCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "User-defined near bank overload current warning + threshold in Amps" + ::= { rPDU2BankConfigEntry 6 } + +rPDU2BankConfigOverloadCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "User-defined bank overload current threshold + in Amps" + ::= { rPDU2BankConfigEntry 7 } + + rPDU2BankConfigBankPeakCurrentReset OBJECT-TYPE + SYNTAX INTEGER { + noOperation (1), + reset (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset (2) will cause the existing peak current value + to be replaced by the present load current value. + + Getting this OID will do nothing and return the noOperation(1) value." + ::= { rPDU2BankConfigEntry 8 } + +-- rPDU2 Bank Properties + +rPDU2BankPropertiesTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2BankPropertiesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU bank properties" + ::= { rPDU2Bank 2 } + +rPDU2BankPropertiesEntry OBJECT-TYPE + SYNTAX RPDU2BankPropertiesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Properties of the currently queried + Rack PDU bank" + INDEX { rPDU2BankPropertiesIndex } + ::= { rPDU2BankPropertiesTable 1 } + +RPDU2BankPropertiesEntry ::= + SEQUENCE { + rPDU2BankPropertiesIndex INTEGER, + rPDU2BankPropertiesModule INTEGER, + rPDU2BankPropertiesNumber INTEGER, + rPDU2BankPropertiesPhaseLayout Rpdu2OutletPhaseLayoutType + } + +rPDU2BankPropertiesIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU bank properties + table entry" + ::= { rPDU2BankPropertiesEntry 1 } + +rPDU2BankPropertiesModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2BankPropertiesEntry 2 } + +rPDU2BankPropertiesNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The numeric bank ID" + ::= { rPDU2BankPropertiesEntry 3 } + +rPDU2BankPropertiesPhaseLayout OBJECT-TYPE + SYNTAX Rpdu2OutletPhaseLayoutType + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID describes the outlet phase connections on + the referenced bank as follows: + + seqPhase1ToNeutral(1) indicates that bank outlets are + wired from Phase 1 to Neutral. + + seqPhase2ToNeutral(2) indicates that bank outlets are + wired from Phase 2 to Neutral. + + seqPhase3ToNeutral(3) indicates that bank outlets are + wired from Phase 3 to Neutral. + + seqPhase1ToPhase2(4) indicates that bank outlets are + wired from Phase 1 to Phase 2. + + seqPhase2ToPhase3(5) indicates that bank outlets are + wired from Phase 2 to Phase 3. + + seqPhase3ToPhase1(6) indicates that bank outlets are + wired from Phase 3 to Phase 1." + ::= { rPDU2BankPropertiesEntry 4 } + +-- rPDU2 Bank Status + +rPDU2BankStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2BankStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU bank status data" + ::= { rPDU2Bank 3 } + +rPDU2BankStatusEntry OBJECT-TYPE + SYNTAX RPDU2BankStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Status data from currently queried Rack PDU + bank" + INDEX { rPDU2BankStatusIndex } + ::= { rPDU2BankStatusTable 1 } + +RPDU2BankStatusEntry ::= + SEQUENCE { + rPDU2BankStatusIndex INTEGER, + rPDU2BankStatusModule INTEGER, + rPDU2BankStatusNumber INTEGER, + rPDU2BankStatusLoadState INTEGER, + rPDU2BankStatusCurrent INTEGER, + rPDU2BankStatusPeakCurrent INTEGER, + rPDU2BankStatusPeakCurrentTimestamp DisplayString, + rPDU2BankStatusPeakCurrentStartTime DisplayString + } + +rPDU2BankStatusIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU bank status + table entry" + ::= { rPDU2BankStatusEntry 1 } + +rPDU2BankStatusModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2BankStatusEntry 2 } + +rPDU2BankStatusNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The numeric bank ID" + ::= { rPDU2BankStatusEntry 3 } + +rPDU2BankStatusLoadState OBJECT-TYPE + SYNTAX INTEGER { + lowLoad (1), + normal (2), + nearOverload (3), + overload (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the present load status of the Rack PDU + bank being queried" + ::= { rPDU2BankStatusEntry 4 } + +rPDU2BankStatusCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the current draw, in tenths of Amps, of the load + on the Rack PDU bank being queried" + ::= { rPDU2BankStatusEntry 5 } + +rPDU2BankStatusPeakCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The peak current of the Rack PDU bank load in tenths of Amps" + ::= { rPDU2BankStatusEntry 6 } + +rPDU2BankStatusPeakCurrentTimestamp OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the date and time the bank peak current occurred" + ::= { rPDU2BankStatusEntry 7 } + +rPDU2BankStatusPeakCurrentStartTime OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the date and time of the last bank peak current reset" + ::= { rPDU2BankStatusEntry 8 } + +-- rPDU2 Outlet Data + +rPDU2Outlet OBJECT IDENTIFIER ::= { rPDU2 9 } + +-- rPDU2 Switched Outlet Data + +rPDU2OutletSwitchedTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of switched outlets on connected Rack PDUs" + ::= { rPDU2Outlet 1} + +rPDU2OutletSwitched OBJECT IDENTIFIER ::= { rPDU2Outlet 2 } + +-- rPDU2 Switched Outlet Config + +rPDU2OutletSwitchedConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2OutletSwitchedConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU switched outlet configuration data" + ::= { rPDU2OutletSwitched 1 } + +rPDU2OutletSwitchedConfigEntry OBJECT-TYPE + SYNTAX RPDU2OutletSwitchedConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Configuration data from currently queried + Rack PDU switched outlet" + INDEX { rPDU2OutletSwitchedConfigIndex } + ::= { rPDU2OutletSwitchedConfigTable 1 } + +RPDU2OutletSwitchedConfigEntry ::= + SEQUENCE { + rPDU2OutletSwitchedConfigIndex INTEGER, + rPDU2OutletSwitchedConfigModule INTEGER, + rPDU2OutletSwitchedConfigName DisplayString, + rPDU2OutletSwitchedConfigNumber INTEGER, + rPDU2OutletSwitchedConfigPowerOnTime INTEGER, + rPDU2OutletSwitchedConfigPowerOffTime INTEGER, + rPDU2OutletSwitchedConfigRebootDuration INTEGER + } + +rPDU2OutletSwitchedConfigIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU switched outlet + configuration table entry" + ::= { rPDU2OutletSwitchedConfigEntry 1 } + +rPDU2OutletSwitchedConfigModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2OutletSwitchedConfigEntry 2 } + +rPDU2OutletSwitchedConfigName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The user-defined switched outlet ID string" + ::= { rPDU2OutletSwitchedConfigEntry 3 } + +rPDU2OutletSwitchedConfigNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The numeric switched outlet ID" + ::= { rPDU2OutletSwitchedConfigEntry 4 } + +rPDU2OutletSwitchedConfigPowerOnTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of delay, in seconds, between when + power is provided to the Rack PDU and when + this switched outlet starts providing power. + Range -1...300 where -1 = Never power on, + 0 = immediate power on, and 1-300 = seconds to + delay." + ::= { rPDU2OutletSwitchedConfigEntry 5 } + +rPDU2OutletSwitchedConfigPowerOffTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of time, in seconds, this outlet will + delay powering off. + Range -1...300 where -1 = Never power off, + 0 = immediate power off, and 1-300 = seconds to + delay." + ::= { rPDU2OutletSwitchedConfigEntry 6 } + +rPDU2OutletSwitchedConfigRebootDuration OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "After turning power off during a reboot sequence, + the amount of time to wait before turning power + to this outlet back on. + Range 5-60 seconds delay." + ::= { rPDU2OutletSwitchedConfigEntry 7 } + +-- rPDU2 Switched Outlet Config + +rPDU2OutletSwitchedPropertiesTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2OutletSwitchedPropertiesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU switched outlet properties" + ::= { rPDU2OutletSwitched 2 } + +rPDU2OutletSwitchedPropertiesEntry OBJECT-TYPE + SYNTAX RPDU2OutletSwitchedPropertiesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Properties of the currently queried Rack PDU + switched outlet" + INDEX { rPDU2OutletSwitchedPropertiesIndex } + ::= { rPDU2OutletSwitchedPropertiesTable 1 } + +RPDU2OutletSwitchedPropertiesEntry ::= + SEQUENCE { + rPDU2OutletSwitchedPropertiesIndex INTEGER, + rPDU2OutletSwitchedPropertiesModule INTEGER, + rPDU2OutletSwitchedPropertiesName DisplayString, + rPDU2OutletSwitchedPropertiesNumber INTEGER, + rPDU2OutletSwitchedPropertiesPhaseLayout Rpdu2OutletPhaseLayoutType, + rPDU2OutletSwitchedPropertiesBank INTEGER + } + +rPDU2OutletSwitchedPropertiesIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU switched outlet + properties table entry" + ::= { rPDU2OutletSwitchedPropertiesEntry 1 } + +rPDU2OutletSwitchedPropertiesModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2OutletSwitchedPropertiesEntry 2 } + +rPDU2OutletSwitchedPropertiesName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined switched outlet ID string" + ::= { rPDU2OutletSwitchedPropertiesEntry 3 } + +rPDU2OutletSwitchedPropertiesNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The numeric switched outlet ID" + ::= { rPDU2OutletSwitchedPropertiesEntry 4 } + +rPDU2OutletSwitchedPropertiesPhaseLayout OBJECT-TYPE + SYNTAX Rpdu2OutletPhaseLayoutType + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID describes the phase connections of + the referenced outlet as follows: + + seqPhase1ToNeutral(1) indicates that the outlet is + wired from Phase 1 to Neutral. + + seqPhase2ToNeutral(2) indicates that the outlet is + wired from Phase 2 to Neutral. + + seqPhase3ToNeutral(3) indicates that the outlet is + wired from Phase 3 to Neutral. + + seqPhase1ToPhase2(4) indicates that the outlet is + wired from Phase 1 to Phase 2. + + seqPhase2ToPhase3(5) indicates that the outlet is + wired from Phase 2 to Phase 3. + + seqPhase3ToPhase1(6) indicates that the outlet is + wired from Phase 3 to Phase 1." + ::= { rPDU2OutletSwitchedPropertiesEntry 5 } + +rPDU2OutletSwitchedPropertiesBank OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The numeric bank ID" + ::= { rPDU2OutletSwitchedPropertiesEntry 6 } + +-- rPDU2 Switched Outlet Status + +rPDU2OutletSwitchedStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2OutletSwitchedStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU switched outlet status + information" + ::= { rPDU2OutletSwitched 3 } + +rPDU2OutletSwitchedStatusEntry OBJECT-TYPE + SYNTAX RPDU2OutletSwitchedStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Status information for currently queried + Rack PDU switched outlet" + INDEX { rPDU2OutletSwitchedStatusIndex } + ::= { rPDU2OutletSwitchedStatusTable 1 } + +RPDU2OutletSwitchedStatusEntry ::= + SEQUENCE { + rPDU2OutletSwitchedStatusIndex INTEGER, + rPDU2OutletSwitchedStatusModule INTEGER, + rPDU2OutletSwitchedStatusName DisplayString, + rPDU2OutletSwitchedStatusNumber INTEGER, + rPDU2OutletSwitchedStatusState INTEGER, + rPDU2OutletSwitchedStatusCommandPending INTEGER + } + +rPDU2OutletSwitchedStatusIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU switched outlet + status information table entry" + ::= { rPDU2OutletSwitchedStatusEntry 1 } + +rPDU2OutletSwitchedStatusModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2OutletSwitchedStatusEntry 2 } + +rPDU2OutletSwitchedStatusName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined switched outlet ID string" + ::= { rPDU2OutletSwitchedStatusEntry 3 } + +rPDU2OutletSwitchedStatusNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The numeric switched outlet ID" + ::= { rPDU2OutletSwitchedStatusEntry 4 } + +rPDU2OutletSwitchedStatusState OBJECT-TYPE + SYNTAX INTEGER { + off (1), + on (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the present switch state of the Rack + PDU switched outlet being queried" + ::= { rPDU2OutletSwitchedStatusEntry 5 } + +rPDU2OutletSwitchedStatusCommandPending OBJECT-TYPE + SYNTAX INTEGER { + commandPending (1), + noCommandPending (2), + commandPendingUnknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not the device is + processing a command for this outlet. + + If the commandPendingUnknown (3) value is + returned, all devices powered by the Rack PDU + should be shut down. The Rack PDU's power + should then be cycled to clear this condition." + ::= { rPDU2OutletSwitchedStatusEntry 6 } + +-- rPDU2 Switched Outlet Control + +rPDU2OutletSwitchedControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2OutletSwitchedControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU switched outlet control + data" + ::= { rPDU2OutletSwitched 4 } + +rPDU2OutletSwitchedControlEntry OBJECT-TYPE + SYNTAX RPDU2OutletSwitchedControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Control data for currently queried Rack + PDU switched outlet" + INDEX { rPDU2OutletSwitchedControlIndex } + ::= { rPDU2OutletSwitchedControlTable 1 } + +RPDU2OutletSwitchedControlEntry ::= + SEQUENCE { + rPDU2OutletSwitchedControlIndex INTEGER, + rPDU2OutletSwitchedControlModule INTEGER, + rPDU2OutletSwitchedControlName DisplayString, + rPDU2OutletSwitchedControlNumber INTEGER, + rPDU2OutletSwitchedControlCommand INTEGER + } + +rPDU2OutletSwitchedControlIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU switched outlet + control data table entry" + ::= { rPDU2OutletSwitchedControlEntry 1 } + +rPDU2OutletSwitchedControlModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2OutletSwitchedControlEntry 2 } + +rPDU2OutletSwitchedControlName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined switched outlet ID string" + ::= { rPDU2OutletSwitchedControlEntry 3 } + +rPDU2OutletSwitchedControlNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The numeric switched outlet ID" + ::= { rPDU2OutletSwitchedControlEntry 4 } + +rPDU2OutletSwitchedControlCommand OBJECT-TYPE + SYNTAX INTEGER { + immediateOn (1), + immediateOff (2), + immediateReboot (3), + outletUnknown (4), + delayedOn (5), + delayedOff (6), + delayedReboot (7), + cancelPendingCommand (8) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this variable will return the outlet state. If + the outlet is on, the immediateOn (1) value will be returned. + If the outlet is off, the immediateOff (2) value will be + returned. If the state of the outlet cannot be + determined, the outletUnknown (4) value will be returned. + If the outletUnknown condition should occur, all devices + powered by the PDU should be shut down. The PDU's power + should then be cycled to clear this condition. + + Setting this variable to immediateOn (1) will immediately turn + the outlet on. + + Setting this variable to immediateOff (2) will immediately turn + the outlet off. + + Setting this variable to immediateReboot (3) will cause the + Switched Rack PDU to perform an immediateOff command, wait the + rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform an + immediateOn command. + + Setting this variable to delayedOn (5) will turn the outlet on + after the rPDU2OutletSwitchedConfigPowerOnTime OID time has elapsed. + + Setting this variable to delayedOff (6) will turn the outlet off + after the rPDU2OutletSwitchedConfigPowerOffTime OID time has elapsed. + + Setting this variable to delayedReboot (7) will cause the + Switched Rack PDU to perform a delayedOff command, wait the + rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform a + delayedOn command. + + Setting this variable to cancelPendingCommand (8) will cause any + pending command to this outlet to be cancelled." + ::= { rPDU2OutletSwitchedControlEntry 5 } + +-- rPDU2 Metered Outlet Data + +rPDU2OutletMeteredTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of metered outlets on connect Rack PDUs" + ::= { rPDU2Outlet 3} + +rPDU2OutletMetered OBJECT IDENTIFIER ::= { rPDU2Outlet 4 } + +-- rPDU2 Metered Outlet Config + +rPDU2OutletMeteredConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2OutletMeteredConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU metered outlet configuration data" + ::= { rPDU2OutletMetered 1 } + +rPDU2OutletMeteredConfigEntry OBJECT-TYPE + SYNTAX RPDU2OutletMeteredConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Configuration data from currently queried + Rack PDU metered outlet" + INDEX { rPDU2OutletMeteredConfigIndex } + ::= { rPDU2OutletMeteredConfigTable 1 } + +RPDU2OutletMeteredConfigEntry ::= + SEQUENCE { + rPDU2OutletMeteredConfigIndex INTEGER, + rPDU2OutletMeteredConfigModule INTEGER, + rPDU2OutletMeteredConfigName DisplayString, + rPDU2OutletMeteredConfigNumber INTEGER, + rPDU2OutletMeteredConfigLowLoadCurrentThreshold INTEGER, + rPDU2OutletMeteredConfigNearOverloadCurrentThreshold INTEGER, + rPDU2OutletMeteredConfigOverloadCurrentThreshold INTEGER + } + +rPDU2OutletMeteredConfigIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU metered outlet + configuration table entry" + ::= { rPDU2OutletMeteredConfigEntry 1 } + +rPDU2OutletMeteredConfigModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2OutletMeteredConfigEntry 2 } + +rPDU2OutletMeteredConfigName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The user-defined metered outlet ID string" + ::= { rPDU2OutletMeteredConfigEntry 3 } + +rPDU2OutletMeteredConfigNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The numeric switched outlet ID" + ::= { rPDU2OutletMeteredConfigEntry 4 } + +rPDU2OutletMeteredConfigLowLoadCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "User-defined low load outlet current threshold in Watts" + ::= { rPDU2OutletMeteredConfigEntry 5 } + +rPDU2OutletMeteredConfigNearOverloadCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "User-defined near outlet overload warning threshold + in Watts" + ::= { rPDU2OutletMeteredConfigEntry 6 } + +rPDU2OutletMeteredConfigOverloadCurrentThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "User-defined outlet overload current threshold in Watts" + ::= { rPDU2OutletMeteredConfigEntry 7 } + +-- rPDU2 Metered Outlet Properties + +rPDU2OutletMeteredPropertiesTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2OutletMeteredPropertiesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU metered outlet properties" + ::= { rPDU2OutletMetered 2 } + +rPDU2OutletMeteredPropertiesEntry OBJECT-TYPE + SYNTAX RPDU2OutletMeteredPropertiesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Properties of currently queried Rack PDU + metered outlet" + INDEX { rPDU2OutletMeteredPropertiesIndex } + ::= { rPDU2OutletMeteredPropertiesTable 1 } + +RPDU2OutletMeteredPropertiesEntry ::= + SEQUENCE { + rPDU2OutletMeteredPropertiesIndex INTEGER, + rPDU2OutletMeteredPropertiesModule INTEGER, + rPDU2OutletMeteredPropertiesName DisplayString, + rPDU2OutletMeteredPropertiesNumber INTEGER, + rPDU2OutletMeteredPropertiesLayout Rpdu2OutletPhaseLayoutType, + rPDU2OutletMeteredPropertiesPowerRating INTEGER, + rPDU2OutletMeteredPropertiesBank INTEGER + } + +rPDU2OutletMeteredPropertiesIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU metered properties table + entry" + ::= { rPDU2OutletMeteredPropertiesEntry 1 } + +rPDU2OutletMeteredPropertiesModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2OutletMeteredPropertiesEntry 2 } + +rPDU2OutletMeteredPropertiesName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined metered outlet ID string" + ::= { rPDU2OutletMeteredPropertiesEntry 3 } + +rPDU2OutletMeteredPropertiesNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The numeric metered outlet ID" + ::= { rPDU2OutletMeteredPropertiesEntry 4 } + +rPDU2OutletMeteredPropertiesLayout OBJECT-TYPE + SYNTAX Rpdu2OutletPhaseLayoutType + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID describes the phase connections of + the referenced outlet as follows: + + seqPhase1ToNeutral(1) indicates that the outlet is + wired from Phase 1 to Neutral. + + seqPhase2ToNeutral(2) indicates that the outlet is + wired from Phase 2 to Neutral. + + seqPhase3ToNeutral(3) indicates that the outlet is + wired from Phase 3 to Neutral. + + seqPhase1ToPhase2(4) indicates that the outlet is + wired from Phase 1 to Phase 2. + + seqPhase2ToPhase3(5) indicates that the outlet is + wired from Phase 2 to Phase 3. + + seqPhase3ToPhase1(6) indicates that the outlet is + wired from Phase 3 to Phase 1." + ::= { rPDU2OutletMeteredPropertiesEntry 5 } + +rPDU2OutletMeteredPropertiesPowerRating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Maximum power rating of Rack PDU metered outlet" + ::= { rPDU2OutletMeteredPropertiesEntry 6 } + +rPDU2OutletMeteredPropertiesBank OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This outlet's numeric bank ID" + ::= { rPDU2OutletMeteredPropertiesEntry 7 } + +-- rPDU2 Metered Outlet Status + +rPDU2OutletMeteredStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2OutletMeteredStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU metered outlet status data" + ::= { rPDU2OutletMetered 3 } + +rPDU2OutletMeteredStatusEntry OBJECT-TYPE + SYNTAX RPDU2OutletMeteredStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Status data from currently queried Rack PDU + metered outlet" + INDEX { rPDU2OutletMeteredStatusIndex } + ::= { rPDU2OutletMeteredStatusTable 1 } + +RPDU2OutletMeteredStatusEntry ::= + SEQUENCE { + rPDU2OutletMeteredStatusIndex INTEGER, + rPDU2OutletMeteredStatusModule INTEGER, + rPDU2OutletMeteredStatusName DisplayString, + rPDU2OutletMeteredStatusNumber INTEGER, + rPDU2OutletMeteredStatusState INTEGER, + rPDU2OutletMeteredStatusCurrent INTEGER, + rPDU2OutletMeteredStatusPower INTEGER, + rPDU2OutletMeteredStatusPeakPower INTEGER, + rPDU2OutletMeteredStatusPeakPowerTimestamp DisplayString, + rPDU2OutletMeteredStatusPeakPowerStartTime DisplayString, + rPDU2OutletMeteredStatusEnergy INTEGER + } + +rPDU2OutletMeteredStatusIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU metered status table + entry" + ::= { rPDU2OutletMeteredStatusEntry 1 } + +rPDU2OutletMeteredStatusModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2OutletMeteredStatusEntry 2 } + +rPDU2OutletMeteredStatusName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined metered outlet ID string" + ::= { rPDU2OutletMeteredStatusEntry 3 } + +rPDU2OutletMeteredStatusNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The numeric metered outlet ID" + ::= { rPDU2OutletMeteredStatusEntry 4 } + +rPDU2OutletMeteredStatusState OBJECT-TYPE + SYNTAX INTEGER { + lowLoad (1), + normal (2), + nearOverload (3), + overload (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the present load status of the Rack + PDU metered outlet being queried" + ::= { rPDU2OutletMeteredStatusEntry 5 } + +rPDU2OutletMeteredStatusCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the current draw, in tenths + of Amps, of the load on the Rack PDU + outlet being queried" + ::= { rPDU2OutletMeteredStatusEntry 6 } + +rPDU2OutletMeteredStatusPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the power draw of the load + on the Rack PDU outlet being queried" + ::= { rPDU2OutletMeteredStatusEntry 7 } + +rPDU2OutletMeteredStatusPeakPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the peak power load draw + on the Rack PDU outlet being queried" + ::= { rPDU2OutletMeteredStatusEntry 8 } + +rPDU2OutletMeteredStatusPeakPowerTimestamp OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the date and time that this metered + outlet's peak power consumption occurred" + ::= { rPDU2OutletMeteredStatusEntry 9 } + +rPDU2OutletMeteredStatusPeakPowerStartTime OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the start date and time that this metered + outlet began recording peak power observations" + ::= { rPDU2OutletMeteredStatusEntry 10 } + +rPDU2OutletMeteredStatusEnergy OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A user resettable energy meter measuring Rack PDU load + energy consumption in tenths of kilowatt-hours" + ::= { rPDU2OutletMeteredStatusEntry 11 } + +-- rPDU2 Sensor Data + +rPDU2Sensor OBJECT IDENTIFIER ::= { rPDU2 10 } + +-- rPDU2 Temperature and Humidity Sensor Data + +rPDU2SensorTempHumidityTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of connected temperature-humidity sensors" + ::= { rPDU2Sensor 1} + +rPDU2SensorTempHumidity OBJECT IDENTIFIER ::= { rPDU2Sensor 2 } + +-- rPDU2 Temperature and Humidity Sensor Config + +rPDU2SensorTempHumidityConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2SensorTempHumidityConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of temperature-humidity sensor + configuration data" + ::= { rPDU2SensorTempHumidity 1 } + +rPDU2SensorTempHumidityConfigEntry OBJECT-TYPE + SYNTAX RPDU2SensorTempHumidityConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Configuration data from temperature-humidity sensor + being queried" + INDEX { rPDU2SensorTempHumidityConfigIndex } + ::= { rPDU2SensorTempHumidityConfigTable 1 } + +RPDU2SensorTempHumidityConfigEntry ::= + SEQUENCE { + rPDU2SensorTempHumidityConfigIndex INTEGER, + rPDU2SensorTempHumidityConfigModule INTEGER, + rPDU2SensorTempHumidityConfigName DisplayString, + rPDU2SensorTempHumidityConfigNumber INTEGER, + rPDU2SensorTempHumidityConfigTemperatureAlarmEnable INTEGER, + rPDU2SensorTempHumidityConfigHumidityAlarmEnable INTEGER, + rPDU2SensorTempHumidityConfigTempMaxThreshF INTEGER, + rPDU2SensorTempHumidityConfigTempHighThreshF INTEGER, + rPDU2SensorTempHumidityConfigTempHysteresisF INTEGER, + rPDU2SensorTempHumidityConfigTempMaxThreshC INTEGER, + rPDU2SensorTempHumidityConfigTempHighThreshC INTEGER, + rPDU2SensorTempHumidityConfigTempHysteresisC INTEGER, + rPDU2SensorTempHumidityConfigHumidityLowThresh INTEGER, + rPDU2SensorTempHumidityConfigHumidityMinThresh INTEGER, + rPDU2SensorTempHumidityConfigHumidityHysteresis INTEGER + } + +rPDU2SensorTempHumidityConfigIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the temperature-humidity sensor + configuration data table entry" + ::= { rPDU2SensorTempHumidityConfigEntry 1 } + +rPDU2SensorTempHumidityConfigModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2SensorTempHumidityConfigEntry 2 } + +rPDU2SensorTempHumidityConfigName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The user-defined temperature-humidity + sensor ID string" + ::= { rPDU2SensorTempHumidityConfigEntry 3 } + +rPDU2SensorTempHumidityConfigNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature-humidity sensor numeric ID" + ::= { rPDU2SensorTempHumidityConfigEntry 4 } + +rPDU2SensorTempHumidityConfigTemperatureAlarmEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID enables or disables generation + of sensor temperature alarm. + + Getting this OID returns the current value of + the temperature alarm enable." + ::= { rPDU2SensorTempHumidityConfigEntry 5 } + +rPDU2SensorTempHumidityConfigHumidityAlarmEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID enables or disables generation + of sensor humidity alarm. + + Getting this OID returns the current value of + the humidity alarm enable." + ::= { rPDU2SensorTempHumidityConfigEntry 6 } + +rPDU2SensorTempHumidityConfigTempMaxThreshF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sensor maximum temperature alarm threshold in + Fahrenheit. Attempting to set this OID to a + value less than or equal to that of + rPDU2SensorTempHumidityConfigTempHighThreshF + will result in an error." + ::= { rPDU2SensorTempHumidityConfigEntry 7 } + +rPDU2SensorTempHumidityConfigTempHighThreshF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sensor high temperature warning alarm threshold + in Fahrenheit. Attempting to set this OID to a + value greater than or equal to that of + rPDU2SensorTempHumidityConfigTempMaxThreshF + will result in an error." + ::= { rPDU2SensorTempHumidityConfigEntry 8 } + +rPDU2SensorTempHumidityConfigTempHysteresisF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sensor temperature hysteresis setting in Fahrenheit" + ::= { rPDU2SensorTempHumidityConfigEntry 9 } + +rPDU2SensorTempHumidityConfigTempMaxThreshC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sensor maximum temperature alarm threshold + in Celsius. Attempting to set this OID to a + value less than or equal to that of + rPDU2SensorTempHumidityConfigTempHighThreshC + will result in an error." + ::= { rPDU2SensorTempHumidityConfigEntry 10 } + +rPDU2SensorTempHumidityConfigTempHighThreshC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sensor high temperature warning alarm threshold + in Celsius. Attempting to set this OID to a + value greater than or equal to that of + rPDU2SensorTempHumidityConfigTempMaxThreshC + will result in an error." + ::= { rPDU2SensorTempHumidityConfigEntry 11 } + +rPDU2SensorTempHumidityConfigTempHysteresisC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sensor temperature hysteresis setting in Celsius" + ::= { rPDU2SensorTempHumidityConfigEntry 12 } + +rPDU2SensorTempHumidityConfigHumidityLowThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sensor low humidity warning alarm threshold in percent + relative humidity. Attempting to set this OID to a + value less than or equal to that of + rPDU2SensorTempHumidityConfigHumidityMinThresh + will result in an error. Must be between 15% and 90%" + ::= { rPDU2SensorTempHumidityConfigEntry 13 } + +rPDU2SensorTempHumidityConfigHumidityMinThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sensor minimum humidity alarm threshold in percent + relative humidity. Attempting to set this OID to a + value greater than or equal to that of + rPDU2SensorTempHumidityConfigHumidityLowThresh + will result in an error. Must be between 15% and 90%" + ::= { rPDU2SensorTempHumidityConfigEntry 14 } + +rPDU2SensorTempHumidityConfigHumidityHysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sensor humidity hysteresis setting in percent relative + humidity" + ::= { rPDU2SensorTempHumidityConfigEntry 15 } + +-- rPDU2 Temperature and Humidity Sensor Status + +rPDU2SensorTempHumidityStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2SensorTempHumidityStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of temperature-humidity sensor status data" + ::= { rPDU2SensorTempHumidity 2 } + +rPDU2SensorTempHumidityStatusEntry OBJECT-TYPE + SYNTAX RPDU2SensorTempHumidityStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Status information from temperature-humidity sensor + being queried" + INDEX { rPDU2SensorTempHumidityStatusIndex } + ::= { rPDU2SensorTempHumidityStatusTable 1 } + +RPDU2SensorTempHumidityStatusEntry ::= + SEQUENCE { + rPDU2SensorTempHumidityStatusIndex INTEGER, + rPDU2SensorTempHumidityStatusModule INTEGER, + rPDU2SensorTempHumidityStatusName DisplayString, + rPDU2SensorTempHumidityStatusNumber INTEGER, + rPDU2SensorTempHumidityStatusType INTEGER, + rPDU2SensorTempHumidityStatusCommStatus INTEGER, + rPDU2SensorTempHumidityStatusTempF INTEGER, + rPDU2SensorTempHumidityStatusTempC INTEGER, + rPDU2SensorTempHumidityStatusTempStatus INTEGER, + rPDU2SensorTempHumidityStatusRelativeHumidity INTEGER, + rPDU2SensorTempHumidityStatusHumidityStatus INTEGER + } + +rPDU2SensorTempHumidityStatusIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the temperature-humidity + status data table entry" + ::= { rPDU2SensorTempHumidityStatusEntry 1 } + +rPDU2SensorTempHumidityStatusModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2SensorTempHumidityStatusEntry 2 } + +rPDU2SensorTempHumidityStatusName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined temperature-humidity + sensor ID string" + ::= { rPDU2SensorTempHumidityStatusEntry 3 } + +rPDU2SensorTempHumidityStatusNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature-humidity sensor numeric ID" + ::= { rPDU2SensorTempHumidityStatusEntry 4 } + +rPDU2SensorTempHumidityStatusType OBJECT-TYPE + SYNTAX INTEGER { + temperatureOnly (1), + temperatureHumidity (2), + commsLost (3), + notInstalled (4) + + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of the sensor" + ::= { rPDU2SensorTempHumidityStatusEntry 5 } + +rPDU2SensorTempHumidityStatusCommStatus OBJECT-TYPE + SYNTAX INTEGER { + notInstalled (1), + commsOK (2), + commsLost (3) + } + ACCESS read-only + + STATUS mandatory + DESCRIPTION + "The communications status of the sensor" + ::= { rPDU2SensorTempHumidityStatusEntry 6 } + +rPDU2SensorTempHumidityStatusTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor temperature reading in tenths of degrees Fahrenheit" + ::= { rPDU2SensorTempHumidityStatusEntry 7 } + +rPDU2SensorTempHumidityStatusTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor temperature reading in tenths of degrees Celsius" + ::= { rPDU2SensorTempHumidityStatusEntry 8 } + +rPDU2SensorTempHumidityStatusTempStatus OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + belowMin (2), + belowLow (3), + normal (4), + aboveHigh (5), + aboveMax (6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID reports the current state of the temperature probe. + + A notPresent (1) response indicates that no probe is attached. + A belowMin (2) response indicates that the probe is present and + its measured temperature lies below the minimum threshold. + A belowLow (3) response indicates that the probe is present and + its measured temperature lies below the low threshold. + A normal (4) response indicates that the probe is present + and its measured temperature lies within all temperature thresholds. + An aboveHigh (5) response indicates that the probe is present + and is measuring a temperature above the high threshold. + An aboveMax (6) response indicates that the probe is present + and is measuring a temperature above the max threshold." + ::= { rPDU2SensorTempHumidityStatusEntry 9 } + +rPDU2SensorTempHumidityStatusRelativeHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor humidity reading in percent relative humidity" + ::= { rPDU2SensorTempHumidityStatusEntry 10 } + +rPDU2SensorTempHumidityStatusHumidityStatus OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + belowMin (2), + belowLow (3), + normal (4), + aboveHigh (5), + aboveMax (6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID reports the current state of the humidity probe. + + A notPresent (1) response indicates that no probe is attached. + A belowMin (2) response indicates that the probe is present and + its measured humidity lies below the minimum threshold. + A belowLow (3) response indicates that the probe is present and + its measured humidity lies below the low threshold. + A normal (4) response indicates that the probe is present + and its measured humidity lies within all humidity thresholds. + An aboveHigh (5) response indicates that the probe is present + and is measuring a humidity above the high threshold. + An aboveMax (6) response indicates that the probe is present + and is measuring a humidity above the max threshold." + ::= { rPDU2SensorTempHumidityStatusEntry 11 } + +-- rPDU2 Discrete Sensor Data + +rPDU2SensorDiscreteTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of connected discrete sensors" + ::= { rPDU2Sensor 3} + +rPDU2SensorDiscrete OBJECT IDENTIFIER ::= { rPDU2Sensor 4 } + +-- rPDU2 Discrete Sensor Config + +rPDU2SensorDiscreteConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2SensorDiscreteConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of discrete sensor configuration + data" + ::= { rPDU2SensorDiscrete 1 } + +rPDU2SensorDiscreteConfigEntry OBJECT-TYPE + SYNTAX RPDU2SensorDiscreteConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Configuration data from discreste sensor + being queried" + INDEX { rPDU2SensorDiscreteConfigIndex } + ::= { rPDU2SensorDiscreteConfigTable 1 } + +RPDU2SensorDiscreteConfigEntry ::= + SEQUENCE { + rPDU2SensorDiscreteConfigIndex INTEGER, + rPDU2SensorDiscreteConfigModule INTEGER, + rPDU2SensorDiscreteConfigName DisplayString, + rPDU2SensorDiscreteConfigNumber INTEGER, + rPDU2SensorDiscreteConfigNormalState INTEGER, + rPDU2SensorDiscreteConfigAbnormalSeverity INTEGER + } + +rPDU2SensorDiscreteConfigIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the discrete sensor configuration + data table entry" + ::= { rPDU2SensorDiscreteConfigEntry 1 } + +rPDU2SensorDiscreteConfigModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2SensorDiscreteConfigEntry 2 } + +rPDU2SensorDiscreteConfigName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The user-defined discrete sensor ID string" + ::= { rPDU2SensorDiscreteConfigEntry 3 } + +rPDU2SensorDiscreteConfigNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The discrete sensor numeric ID" + ::= { rPDU2SensorDiscreteConfigEntry 4 } + +rPDU2SensorDiscreteConfigNormalState OBJECT-TYPE + SYNTAX INTEGER { + normallyOpen (1), + normallyClosed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Indicates the normal state of the discrete input + contact" + ::= { rPDU2SensorDiscreteConfigEntry 5 } + +rPDU2SensorDiscreteConfigAbnormalSeverity OBJECT-TYPE + SYNTAX INTEGER { + informational (1), + warning (2), + critical (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Indicates the severity of alarm triggered by + abnormal discrete input contact state" + ::= { rPDU2SensorDiscreteConfigEntry 6 } + +-- rPDU2 Discrete Sensor Status + +rPDU2SensorDiscreteStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2SensorDiscreteStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of discrete sensor status data" + ::= { rPDU2SensorDiscrete 2 } + +rPDU2SensorDiscreteStatusEntry OBJECT-TYPE + SYNTAX RPDU2SensorDiscreteStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Status information from discrete sensor + being queried" + INDEX { rPDU2SensorDiscreteStatusIndex } + ::= { rPDU2SensorDiscreteStatusTable 1 } + +RPDU2SensorDiscreteStatusEntry ::= + SEQUENCE { + rPDU2SensorDiscreteStatusIndex INTEGER, + rPDU2SensorDiscreteStatusModule INTEGER, + rPDU2SensorDiscreteStatusName DisplayString, + rPDU2SensorDiscreteStatusNumber INTEGER, + rPDU2SensorDiscreteStatusType INTEGER, + rPDU2SensorDiscreteStatusCommStatus INTEGER, + rPDU2SensorDiscreteStatusCurrentState INTEGER, + rPDU2SensorDiscreteStatusAlarmState INTEGER + } + +rPDU2SensorDiscreteStatusIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the discrete sensor status data + table entry" + ::= { rPDU2SensorDiscreteStatusEntry 1 } + +rPDU2SensorDiscreteStatusModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2SensorDiscreteStatusEntry 2 } + +rPDU2SensorDiscreteStatusName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined discrete sensor ID string" + ::= { rPDU2SensorDiscreteStatusEntry 3 } + +rPDU2SensorDiscreteStatusNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The discrete sensor numeric ID" + ::= { rPDU2SensorDiscreteStatusEntry 4 } + +rPDU2SensorDiscreteStatusType OBJECT-TYPE + SYNTAX INTEGER { + notConnected (1), + doorContactSensor (2), + smokeSensor (3), + motionDetector (4), + vibrationSensor (5), + dryContactSensor (6), + spotLeakSensor (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of discrete sensor currently being queried" + ::= { rPDU2SensorDiscreteStatusEntry 5 } + +rPDU2SensorDiscreteStatusCommStatus OBJECT-TYPE + SYNTAX INTEGER { + notInstalled(1), + commsOK(2), + commsLost(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The communications status of the sensor" + ::= { rPDU2SensorDiscreteStatusEntry 6 } + +rPDU2SensorDiscreteStatusCurrentState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2), + unknown (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current open/close state of the discrete + sensor" + ::= { rPDU2SensorDiscreteStatusEntry 7 } + +rPDU2SensorDiscreteStatusAlarmState OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + alarm (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates alarm status of discrete sensor input" + ::= { rPDU2SensorDiscreteStatusEntry 8 } + +rPDU2Group OBJECT IDENTIFIER ::= { rPDU2 11 } + +-- rPDU2 Total Rack PDU Network Port Sharing (NPS) group power and energy + +rPDU2GroupNumberOfDevices OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the number of Rack PDU devices contributing + to the Network Port Sharing (NPS) group power and energy values. + Queries to guest units in an NPS group are not applicable and will + return 0." + + ::= { rPDU2Group 1 } + +rPDU2GroupTotalPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the total power consumption of the Rack PDU + Network Port Sharing (NPS) group devices in hundredths of kilowatts. + Queries to guest units in an NPS group are not applicable and will + return 0." + + ::= { rPDU2Group 2 } + +rPDU2GroupTotalEnergy OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the total energy consumption of the Rack PDU + Network Port Sharing (NPS) group devices in tenths of kilowatt-hours. + + To reset the energy meters for each of the Rack PDU devices that contribute + to this value, see the rPDU2GroupEnergyReset OID. + + To view the start time for each of the Rack PDU device energy meters that + contribute to this value, see the rPDU2DeviceStatusEnergyStartTime OID. + + Queries to guest units in an NPS group are not applicable and will + return 0." + + ::= { rPDU2Group 3 } + +rPDU2GroupEnergyReset OBJECT-TYPE + SYNTAX INTEGER { + noOperation (1), + reset (2), + notSupported (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset (2) will cause the device energy meter value + on each device in the Rack PDU Network Port Sharing (NPS) group to be + reset to zero. + + Each device in the Rack PDU group will also have its corresponding + rPDU2DeviceStatusEnergyStartTime OID value updated. + + Getting this OID in models that support this feature will do nothing + and return the noOperation(1) value. + + Models that do not support this feature, as well as guest units in an + NPS group, will respond to this OID with a value of notSupported (3). + Attempts to set this OID in these units will fail." + + ::= { rPDU2Group 4 } + + +-- rPDU2 Phase To Phase Status +rPDU2PhaseToPhaseStatusTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of connected Rack PDU banks" + ::= { rPDU2 12} + +rPDU2PhaseToPhase OBJECT IDENTIFIER ::= { rPDU2 13 } + +rPDU2PhaseToPhaseStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RPDU2PhaseToPhaseStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of Rack PDU phase to phase status data. + This table is only applicable to SKUs that have + phase to phase outputs." + ::= { rPDU2PhaseToPhase 1 } + +rPDU2PhaseToPhaseStatusEntry OBJECT-TYPE + SYNTAX RPDU2PhaseToPhaseStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Status data from currently queried Rack PDU + phase to phase outputs" + INDEX { rPDU2PhaseToPhaseStatusIndex } + ::= { rPDU2PhaseToPhaseStatusTable 1 } + +RPDU2PhaseToPhaseStatusEntry ::= + SEQUENCE { + rPDU2PhaseToPhaseStatusIndex INTEGER, + rPDU2PhaseToPhaseStatusModule INTEGER, + rPDU2PhaseToPhaseStatusVoltage1to2 INTEGER, + rPDU2PhaseToPhaseStatusVoltage2to3 INTEGER, + rPDU2PhaseToPhaseStatusVoltage3to1 INTEGER + } + +rPDU2PhaseToPhaseStatusIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the Rack PDU phase to phase status table + entry" + ::= { rPDU2PhaseToPhaseStatusEntry 1 } + +rPDU2PhaseToPhaseStatusModule OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user-defined Rack PDU numeric ID" + ::= { rPDU2PhaseToPhaseStatusEntry 2 } + + +rPDU2PhaseToPhaseStatusVoltage1to2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the Voltage, in Volts, of the Rack + PDU phase 1 to phase 2 output being queried" + ::= { rPDU2PhaseToPhaseStatusEntry 3 } + +rPDU2PhaseToPhaseStatusVoltage2to3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the Voltage, in Volts, of the Rack + PDU phase 2 to phase 3 output being queried" + ::= { rPDU2PhaseToPhaseStatusEntry 4 } + +rPDU2PhaseToPhaseStatusVoltage3to1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the Voltage, in Volts, of the Rack + PDU phase 3 to phase 2 output being queried" + ::= { rPDU2PhaseToPhaseStatusEntry 5 } + + + +-- the cooling group + +coolingUnit OBJECT IDENTIFIER ::= { cooling 1 } + +coolingUnitTableSize OBJECT-TYPE + SYNTAX INTEGER (0..2147483647) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of cooling units accessible via this agent." + ::= { coolingUnit 1 } + +coolingUnitTable OBJECT-TYPE + SYNTAX SEQUENCE OF CoolingUnitEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of cooling unit level data." + ::= { coolingUnit 2} + +coolingUnitEntry OBJECT-TYPE + SYNTAX CoolingUnitEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An element of coolingUnitTable." + INDEX { coolingUnitTableIndex } + ::= { coolingUnitTable 1 } + +CoolingUnitEntry ::= SEQUENCE { + coolingUnitTableIndex INTEGER +} + +coolingUnitTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit reference identifier for this table and all other table entries subordinate to coolingUnits." + ::= { coolingUnitEntry 1 } + +coolingUnitAbout OBJECT IDENTIFIER ::= { coolingUnit 3 } + +coolingUnitAboutTableSize OBJECT-TYPE + SYNTAX INTEGER (0..2147483647) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The potential number of entries available in coolingUnitAboutTable." + ::= { coolingUnitAbout 1 } + +coolingUnitAboutTable OBJECT-TYPE + SYNTAX SEQUENCE OF CoolingUnitAboutEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of unit reference information." + ::= { coolingUnitAbout 2} + +coolingUnitAboutEntry OBJECT-TYPE + SYNTAX CoolingUnitAboutEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An element of coolingUnitAboutTable." + INDEX { coolingUnitTableIndex, + coolingUnitAboutTableIndex } + ::= { coolingUnitAboutTable 1 } + +CoolingUnitAboutEntry ::= SEQUENCE { + coolingUnitAboutTableIndex INTEGER, + coolingUnitAboutDescription DisplayString, + coolingUnitAboutValue DisplayString +} + +coolingUnitAboutTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The static reference identifier for each table entry." + ::= { coolingUnitAboutEntry 1 } + +coolingUnitAboutDescription OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A text description of the information presented in coolingUnitAboutValue." + ::= { coolingUnitAboutEntry 2 } + +coolingUnitAboutValue OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual value of the current table entry." + ::= { coolingUnitAboutEntry 3 } + +coolingUnitStatus OBJECT IDENTIFIER ::= { coolingUnit 4 } +coolingUnitStatusAnalog OBJECT IDENTIFIER ::= { coolingUnitStatus 1 } + +coolingUnitStatusAnalogTableSize OBJECT-TYPE + SYNTAX INTEGER (0..2147483647) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The potential number of entries available in coolingUnitStatusAnalogTable." + ::= { coolingUnitStatusAnalog 1 } + +coolingUnitStatusAnalogTable OBJECT-TYPE + SYNTAX SEQUENCE OF CoolingUnitStatusAnalogEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of analog unit status data." + ::= { coolingUnitStatusAnalog 2} + +coolingUnitStatusAnalogEntry OBJECT-TYPE + SYNTAX CoolingUnitStatusAnalogEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An element of coolingUnitStatusAnalogTable." + INDEX { coolingUnitTableIndex, + coolingUnitStatusAnalogTableIndex } + ::= { coolingUnitStatusAnalogTable 1 } + +CoolingUnitStatusAnalogEntry ::= SEQUENCE { + coolingUnitStatusAnalogTableIndex INTEGER, + coolingUnitStatusAnalogDescription DisplayString, + coolingUnitStatusAnalogValue INTEGER, + coolingUnitStatusAnalogUnits DisplayString, + coolingUnitStatusAnalogScale INTEGER +} + +coolingUnitStatusAnalogTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The static reference identifier for each table entry." + ::= { coolingUnitStatusAnalogEntry 1 } + +coolingUnitStatusAnalogDescription OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A text description of the information presented in coolingUnitStatusAnalogValue." + ::= { coolingUnitStatusAnalogEntry 2 } + +coolingUnitStatusAnalogValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The scaled value of the current table entry (multiplied by coolingUnitStatusAnalogScale for integer presentation)." + ::= { coolingUnitStatusAnalogEntry 3 } + +coolingUnitStatusAnalogUnits OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit of measure by which coolingUnitStatusAnalogValue is expressed." + ::= { coolingUnitStatusAnalogEntry 4 } + +coolingUnitStatusAnalogScale OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The factor by which coolingUnitStatusAnalogValue is expressed." + ::= { coolingUnitStatusAnalogEntry 5 } + +coolingUnitStatusDiscrete OBJECT IDENTIFIER ::= { coolingUnitStatus 2 } + +coolingUnitStatusDiscreteTableSize OBJECT-TYPE + SYNTAX INTEGER (0..2147483647) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The potential number of entries available in coolingUnitStatusDiscreteTable." + ::= { coolingUnitStatusDiscrete 1 } + +coolingUnitStatusDiscreteTable OBJECT-TYPE + SYNTAX SEQUENCE OF CoolingUnitStatusDiscreteEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of discrete unit status data." + ::= { coolingUnitStatusDiscrete 2} + +coolingUnitStatusDiscreteEntry OBJECT-TYPE + SYNTAX CoolingUnitStatusDiscreteEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An element of coolingUnitStatusDiscreteTable." + INDEX { coolingUnitTableIndex, + coolingUnitStatusDiscreteTableIndex } + ::= { coolingUnitStatusDiscreteTable 1 } + +CoolingUnitStatusDiscreteEntry ::= SEQUENCE { + coolingUnitStatusDiscreteTableIndex INTEGER, + coolingUnitStatusDiscreteDescription DisplayString, + coolingUnitStatusDiscreteValueAsString DisplayString, + coolingUnitStatusDiscreteValueAsInteger INTEGER, + coolingUnitStatusDiscreteIntegerReferenceKey DisplayString +} + +coolingUnitStatusDiscreteTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The static reference identifier for each table entry." + ::= { coolingUnitStatusDiscreteEntry 1 } + +coolingUnitStatusDiscreteDescription OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A text description of the information presented in this table's 'value' OIDs." + ::= { coolingUnitStatusDiscreteEntry 2 } + +coolingUnitStatusDiscreteValueAsString OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual value of the current table entry expressed as a string." + ::= { coolingUnitStatusDiscreteEntry 3 } + +coolingUnitStatusDiscreteValueAsInteger OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual value of the current table entry expressed as an integer value." + ::= { coolingUnitStatusDiscreteEntry 4 } + +coolingUnitStatusDiscreteIntegerReferenceKey OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A complete listing of all possible coolingUnitStatusDiscreteValueAsInteger values paired with their identifying strings." + ::= { coolingUnitStatusDiscreteEntry 5 } + +coolingUnitConfiguration OBJECT IDENTIFIER ::= { coolingUnit 5 } +coolingUnitConfigurationAnalog OBJECT IDENTIFIER ::= { coolingUnitConfiguration 1 } + +coolingUnitConfigurationAnalogTableSize OBJECT-TYPE + SYNTAX INTEGER (0..2147483647) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The potential number of entries available in coolingUnitConfigurationAnalogTable." + ::= { coolingUnitConfigurationAnalog 1 } + +coolingUnitConfigurationAnalogTable OBJECT-TYPE + SYNTAX SEQUENCE OF CoolingUnitConfigurationAnalogEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of analog unit configuration data." + ::= { coolingUnitConfigurationAnalog 2} + +coolingUnitConfigurationAnalogEntry OBJECT-TYPE + SYNTAX CoolingUnitConfigurationAnalogEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An element of coolingUnitConfigurationAnalogTable." + INDEX { coolingUnitTableIndex, + coolingUnitConfigurationAnalogTableIndex } + ::= { coolingUnitConfigurationAnalogTable 1 } + +CoolingUnitConfigurationAnalogEntry ::= SEQUENCE { + coolingUnitConfigurationAnalogTableIndex INTEGER, + coolingUnitConfigurationAnalogDescription DisplayString, + coolingUnitConfigurationAnalogValue INTEGER, + coolingUnitConfigurationAnalogUnits DisplayString, + coolingUnitConfigurationAnalogScale INTEGER, + coolingUnitConfigurationAnalogAccess INTEGER, + coolingUnitConfigurationAnalogMinimum INTEGER, + coolingUnitConfigurationAnalogMaximum INTEGER +} + +coolingUnitConfigurationAnalogTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The static reference identifier for each table entry." + ::= { coolingUnitConfigurationAnalogEntry 1 } + +coolingUnitConfigurationAnalogDescription OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A text description of the information presented in coolingUnitConfigurationAnalogValue." + ::= { coolingUnitConfigurationAnalogEntry 2 } + +coolingUnitConfigurationAnalogValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The scaled value of the current table entry (multiplied by coolingUnitConfigurationAnalogScale for integer presentation)." + ::= { coolingUnitConfigurationAnalogEntry 3 } + +coolingUnitConfigurationAnalogUnits OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit of measure by which coolingUnitConfigurationAnalogValue is expressed." + ::= { coolingUnitConfigurationAnalogEntry 4 } + +coolingUnitConfigurationAnalogScale OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The factor by which coolingUnitConfigurationAnalogValue is expressed." + ::= { coolingUnitConfigurationAnalogEntry 5 } + +coolingUnitConfigurationAnalogAccess OBJECT-TYPE + SYNTAX INTEGER { + readOnly (1), + readWrite (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A description of available access to coolingUnitConfigurationAnalogValue via SNMP client." + ::= { coolingUnitConfigurationAnalogEntry 6 } + +coolingUnitConfigurationAnalogMinimum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum possible value of coolingUnitConfigurationAnalogValue." + ::= { coolingUnitConfigurationAnalogEntry 7 } + +coolingUnitConfigurationAnalogMaximum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum possible value of coolingUnitConfigurationAnalogValue." + ::= { coolingUnitConfigurationAnalogEntry 8 } + +coolingUnitConfigurationDiscrete OBJECT IDENTIFIER ::= { coolingUnitConfiguration 2 } + +coolingUnitConfigurationDiscreteTableSize OBJECT-TYPE + SYNTAX INTEGER (0..2147483647) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The potential number of entries available in coolingUnitConfigurationDiscreteTable." + ::= { coolingUnitConfigurationDiscrete 1 } + +coolingUnitConfigurationDiscreteTable OBJECT-TYPE + SYNTAX SEQUENCE OF CoolingUnitConfigurationDiscreteEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of discrete unit configuration data." + ::= { coolingUnitConfigurationDiscrete 2} + +coolingUnitConfigurationDiscreteEntry OBJECT-TYPE + SYNTAX CoolingUnitConfigurationDiscreteEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An element of coolingUnitConfigurationDiscreteTable." + INDEX { coolingUnitTableIndex, + coolingUnitConfigurationDiscreteTableIndex } + ::= { coolingUnitConfigurationDiscreteTable 1 } + +CoolingUnitConfigurationDiscreteEntry ::= SEQUENCE { + coolingUnitConfigurationDiscreteTableIndex INTEGER, + coolingUnitConfigurationDiscreteDescription DisplayString, + coolingUnitConfigurationDiscreteValueAsString DisplayString, + coolingUnitConfigurationDiscreteValueAsInteger INTEGER, + coolingUnitConfigurationDiscreteIntegerReferenceKey DisplayString, + coolingUnitConfigurationDiscreteAccess INTEGER +} + +coolingUnitConfigurationDiscreteTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The static reference identifier for each table entry." + ::= { coolingUnitConfigurationDiscreteEntry 1 } + +coolingUnitConfigurationDiscreteDescription OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A text description of the information presented in this table's 'value' OIDs." + ::= { coolingUnitConfigurationDiscreteEntry 2 } + +coolingUnitConfigurationDiscreteValueAsString OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual value of the current table entry expressed as a string." + ::= { coolingUnitConfigurationDiscreteEntry 3 } + +coolingUnitConfigurationDiscreteValueAsInteger OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The actual value of the current table entry expressed as an integer value." + ::= { coolingUnitConfigurationDiscreteEntry 4 } + +coolingUnitConfigurationDiscreteIntegerReferenceKey OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A complete listing of all possible coolingUnitConfigurationDiscreteValueAsInteger values paired with their identifying strings." + ::= { coolingUnitConfigurationDiscreteEntry 5 } + +coolingUnitConfigurationDiscreteAccess OBJECT-TYPE + SYNTAX INTEGER { + readOnly (1), + readWrite (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A description of available access to coolingUnitConfigurationDiscreteValueAsInteger via SNMP client." + ::= { coolingUnitConfigurationDiscreteEntry 6 } + +coolingUnitConfigurationString OBJECT IDENTIFIER ::= { coolingUnitConfiguration 3 } + +coolingUnitConfigurationStringTableSize OBJECT-TYPE + SYNTAX INTEGER (0..2147483647) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The potential number of entries available in coolingUnitConfigurationStringTable." + ::= { coolingUnitConfigurationString 1 } + +coolingUnitConfigurationStringTable OBJECT-TYPE + SYNTAX SEQUENCE OF CoolingUnitConfigurationStringEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of unit configuration strings." + ::= { coolingUnitConfigurationString 2} + +coolingUnitConfigurationStringEntry OBJECT-TYPE + SYNTAX CoolingUnitConfigurationStringEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An element of coolingUnitConfigurationStringTable." + INDEX { coolingUnitTableIndex, + coolingUnitConfigurationStringTableIndex } + ::= { coolingUnitConfigurationStringTable 1 } + +CoolingUnitConfigurationStringEntry ::= SEQUENCE { + coolingUnitConfigurationStringTableIndex INTEGER, + coolingUnitConfigurationStringDescription DisplayString, + coolingUnitConfigurationStringValue DisplayString, + coolingUnitConfigurationStringMaxLength INTEGER, + coolingUnitConfigurationStringAccess INTEGER +} + +coolingUnitConfigurationStringTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The static reference identifier for each table entry." + ::= { coolingUnitConfigurationStringEntry 1 } + +coolingUnitConfigurationStringDescription OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A text description of the information presented in coolingUnitConfigurationStringValue." + ::= { coolingUnitConfigurationStringEntry 2 } + +coolingUnitConfigurationStringValue OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The actual value of the current table entry." + ::= { coolingUnitConfigurationStringEntry 3 } + +coolingUnitConfigurationStringMaxLength OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum string length supported by coolingUnitConfigurationStringValue." + ::= { coolingUnitConfigurationStringEntry 4 } + +coolingUnitConfigurationStringAccess OBJECT-TYPE + SYNTAX INTEGER { + readOnly (1), + readWrite (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A description of available access to coolingUnitConfigurationStringValue via SNMP client." + ::= { coolingUnitConfigurationStringEntry 5 } + +coolingUnitExtended OBJECT IDENTIFIER ::= { coolingUnit 6 } +coolingUnitExtendedAnalog OBJECT IDENTIFIER ::= { coolingUnitExtended 1 } + +coolingUnitExtendedAnalogTableSize OBJECT-TYPE + SYNTAX INTEGER (0..2147483647) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The potential number of entries available in coolingUnitExtendedAnalogTable." + ::= { coolingUnitExtendedAnalog 1 } + +coolingUnitExtendedAnalogTable OBJECT-TYPE + SYNTAX SEQUENCE OF CoolingUnitExtendedAnalogEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of secondary analog data for the cooling unit or one of its components." + ::= { coolingUnitExtendedAnalog 2} + +coolingUnitExtendedAnalogEntry OBJECT-TYPE + SYNTAX CoolingUnitExtendedAnalogEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An element of coolingUnitExtendedAnalogTable." + INDEX { coolingUnitTableIndex, + coolingUnitExtendedAnalogTableIndex } + ::= { coolingUnitExtendedAnalogTable 1 } + +CoolingUnitExtendedAnalogEntry ::= SEQUENCE { + coolingUnitExtendedAnalogTableIndex INTEGER, + coolingUnitExtendedAnalogDescription DisplayString, + coolingUnitExtendedAnalogValue INTEGER, + coolingUnitExtendedAnalogUnits DisplayString, + coolingUnitExtendedAnalogScale INTEGER +} + +coolingUnitExtendedAnalogTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The static reference identifier for each table entry. This identifier may reference different table entries in different unit models." + ::= { coolingUnitExtendedAnalogEntry 1 } + +coolingUnitExtendedAnalogDescription OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A text description of the information presented in coolingUnitExtendedAnalogValue." + ::= { coolingUnitExtendedAnalogEntry 2 } + +coolingUnitExtendedAnalogValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The scaled value of the current table entry (multiplied by coolingUnitExtendedAnalogScale for integer presentation)." + ::= { coolingUnitExtendedAnalogEntry 3 } + +coolingUnitExtendedAnalogUnits OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit of measure by which coolingUnitExtendedAnalogValue is expressed." + ::= { coolingUnitExtendedAnalogEntry 4 } + +coolingUnitExtendedAnalogScale OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The factor by which coolingUnitExtendedAnalogValue is expressed." + ::= { coolingUnitExtendedAnalogEntry 5 } + +coolingUnitExtendedDiscrete OBJECT IDENTIFIER ::= { coolingUnitExtended 2 } + +coolingUnitExtendedDiscreteTableSize OBJECT-TYPE + SYNTAX INTEGER (0..2147483647) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The potential number of entries available in coolingUnitExtendedDiscreteTable." + ::= { coolingUnitExtendedDiscrete 1 } + +coolingUnitExtendedDiscreteTable OBJECT-TYPE + SYNTAX SEQUENCE OF CoolingUnitExtendedDiscreteEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of secondary discrete cooling unit data." + ::= { coolingUnitExtendedDiscrete 2} + +coolingUnitExtendedDiscreteEntry OBJECT-TYPE + SYNTAX CoolingUnitExtendedDiscreteEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An element of coolingUnitExtendedDiscreteTable." + INDEX { coolingUnitTableIndex, + coolingUnitExtendedDiscreteTableIndex } + ::= { coolingUnitExtendedDiscreteTable 1 } + +CoolingUnitExtendedDiscreteEntry ::= SEQUENCE { + coolingUnitExtendedDiscreteTableIndex INTEGER, + coolingUnitExtendedDiscreteDescription DisplayString, + coolingUnitExtendedDiscreteValueAsString DisplayString, + coolingUnitExtendedDiscreteValueAsInteger INTEGER, + coolingUnitExtendedDiscreteIntegerReferenceKey DisplayString +} + +coolingUnitExtendedDiscreteTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The static reference identifier for each table entry. This identifier may reference different table entries in different unit models." + ::= { coolingUnitExtendedDiscreteEntry 1 } + +coolingUnitExtendedDiscreteDescription OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A text description of the information presented in this table's 'value' OIDs." + ::= { coolingUnitExtendedDiscreteEntry 2 } + +coolingUnitExtendedDiscreteValueAsString OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual value of the current table entry expressed as a string." + ::= { coolingUnitExtendedDiscreteEntry 3 } + +coolingUnitExtendedDiscreteValueAsInteger OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual value of the current table entry expressed as an integer value." + ::= { coolingUnitExtendedDiscreteEntry 4 } + +coolingUnitExtendedDiscreteIntegerReferenceKey OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A complete listing of all possible coolingUnitExtendedDiscreteValueAsInteger values paired with their identifying strings." + ::= { coolingUnitExtendedDiscreteEntry 5 } + +coolingUnitExtendedString OBJECT IDENTIFIER ::= { coolingUnitExtended 3 } + +coolingUnitExtendedStringTableSize OBJECT-TYPE + SYNTAX INTEGER (0..2147483647) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The potential number of entries available in coolingUnitExtendedStringTable." + ::= { coolingUnitExtendedString 1 } + +coolingUnitExtendedStringTable OBJECT-TYPE + SYNTAX SEQUENCE OF CoolingUnitExtendedStringEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of secondary unit reference data." + ::= { coolingUnitExtendedString 2} + +coolingUnitExtendedStringEntry OBJECT-TYPE + SYNTAX CoolingUnitExtendedStringEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An element of coolingUnitExtendedStringTable." + INDEX { coolingUnitTableIndex, + coolingUnitExtendedStringTableIndex } + ::= { coolingUnitExtendedStringTable 1 } + +CoolingUnitExtendedStringEntry ::= SEQUENCE { + coolingUnitExtendedStringTableIndex INTEGER, + coolingUnitExtendedStringDescription DisplayString, + coolingUnitExtendedStringValue DisplayString +} + +coolingUnitExtendedStringTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The static reference identifier for each table entry. This identifier may reference different table entries in different unit models." + ::= { coolingUnitExtendedStringEntry 1 } + +coolingUnitExtendedStringDescription OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A text description of the information presented in coolingUnitExtendedStringValue." + ::= { coolingUnitExtendedStringEntry 2 } + +coolingUnitExtendedStringValue OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual value of the current table entry." + ::= { coolingUnitExtendedStringEntry 3 } + + + +-- the dm3IdentSystem group + +dm3IdentSysDescriptionTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC description records." + ::= { dm3IdentSystem 1 } + +dm3IdentSysDescriptionTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dm3IdentSysDescriptionEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for accessing description records of the powerplant. The number of + entries is contained in the dm3IdentSysDescriptionTableSize OID." + ::= { dm3IdentSystem 2 } + +dm3IdentSysDescriptionEntry OBJECT-TYPE + SYNTAX Dm3IdentSysDescriptionEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The powerplant description record to reference." + INDEX { dm3IdentSysDescriptionIndex } + ::= { dm3IdentSysDescriptionTable 1 } + +Dm3IdentSysDescriptionEntry ::= + SEQUENCE { + dm3IdentSysDescriptionIndex INTEGER, + dm3IdentSysDescriptionText DisplayString + } + +dm3IdentSysDescriptionIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant description record." + ::= { dm3IdentSysDescriptionEntry 1 } + +dm3IdentSysDescriptionText OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A 16 character text field describing the DC power plant device. + This field can be configured from the dm3ConfigSysDescriptionText OID." + ::= { dm3IdentSysDescriptionEntry 2 } + +dm3IdentSysModel OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Model type of the DC power plant." + ::= { dm3IdentSystem 3 } + +dm3IdentSysCntrlRev OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Integer representation of the hardware revision of the Master Controller board." + ::= { dm3IdentSystem 4 } + +dm3IdentSysFWVersion OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Integer representation of the power plant Master Controller firmware revision." + ::= { dm3IdentSystem 5 } + +-- the dm3ConfigSystem group + +dm3ConfigSysDescriptionTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC description records." + ::= { dm3ConfigSystem 1 } + +dm3ConfigSysDescriptionTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dm3ConfigSysDescriptionEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for accessing description records of the powerplant. The number of + entries is contained in the dm3ConfigSysDescriptionTableSize OID." + ::= { dm3ConfigSystem 2 } + +dm3ConfigSysDescriptionEntry OBJECT-TYPE + SYNTAX Dm3ConfigSysDescriptionEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The powerplant description record to reference." + INDEX { dm3ConfigSysDescriptionIndex } + ::= { dm3ConfigSysDescriptionTable 1 } + +Dm3ConfigSysDescriptionEntry ::= + SEQUENCE { + dm3ConfigSysDescriptionIndex INTEGER, + dm3ConfigSysDescriptionText DisplayString + } + +dm3ConfigSysDescriptionIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant description record." + + ::= { dm3ConfigSysDescriptionEntry 1 } + +dm3ConfigSysDescriptionText OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "16 character text field describing the DC power plant device." + + ::= { dm3ConfigSysDescriptionEntry 2 } + +dm3ConfigSysHighTempThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Ambient high temperature threshold. Temperature sensor located on Master + Controller board. + + Values are represented in thousandths of a degree. + Units are displayed in the scale shown in + the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). + + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigSystem 3 } + +dm3ConfigSysHighTempAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the System High Temperature Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + ::= { dm3ConfigSystem 4 } + +dm3ConfigSysLowTempThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Ambient low temperature threshold. Temperature sensor located on Master + Controller board. + + Values are represented in thousandths of a degree. + Units are displayed in the scale shown in + the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). + + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigSystem 5 } + +dm3ConfigSysLowTempAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the System Low Temperature Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + ::= { dm3ConfigSystem 6 } + +dm3ConfigSysHardwareTempAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the System Hardware Temperature Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + ::= { dm3ConfigSystem 7 } + +dm3ConfigSysRemoteAccess OBJECT-TYPE + SYNTAX INTEGER { + accessEnabled (1), + accessDisabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " + This OID is used to disable remote write access to the power plant. + Setting this OID to accessEnabled (1) will have no affect. + Setting this OID to accessDisabled (2) will disable the ability to + remotely configure the DC powerplant. + + Once remote access is disabled, it can only be restored from the front + panel of the DC power plant." + ::= { dm3ConfigSystem 8 } + + +-- the dm3ConfigLVD group + +dm3ConfigLVDTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant LVDs controllable + by this IP address." + ::= { dm3ConfigLVD 1 } + +dm3ConfigLVDTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dm3ConfigLVDEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for accessing settings of the LVDs. The number of + entries is contained in the dm3ConfigLVDTableSize OID." + ::= { dm3ConfigLVD 2 } + +dm3ConfigLVDEntry OBJECT-TYPE + SYNTAX Dm3ConfigLVDEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The LVD to configure." + INDEX { dm3ConfigLVDIndex } + ::= { dm3ConfigLVDTable 1 } + +Dm3ConfigLVDEntry ::= + SEQUENCE { + dm3ConfigLVDIndex INTEGER, + dm3ConfigLVDName DisplayString, + dm3ConfigLVDEnable INTEGER, + dm3ConfigLVDTripThresh INTEGER, + dm3ConfigLVDResetThresh INTEGER, + dm3ConfigLVDOpenAlarm INTEGER, + dm3ConfigLVDHWAlarm INTEGER + } + +dm3ConfigLVDIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant LVD." + ::= { dm3ConfigLVDEntry 1 } + +dm3ConfigLVDName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the LVD. The maximum value is 16 characters." + ::= { dm3ConfigLVDEntry 2 } + +dm3ConfigLVDEnable OBJECT-TYPE + SYNTAX INTEGER { + enabledYes (1), + enabledNo (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This OID is used to control and indicate if the LVD is on or off. + Setting this OID to enabledYes (1) will enable (turn on) the LVD. + Setting this OID to enabledNo (2) will disable (turn off) the LVD." + ::= { dm3ConfigLVDEntry 3 } + +dm3ConfigLVDTripThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "LVD Trip threshold. If voltage exceeds threshold, the LVD will trip. + + Values are represented in thousandths of Volts (mV). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigLVDEntry 4 } + +dm3ConfigLVDResetThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "LVD Reset threshold. If voltage exceeds threshold, the LVD will reset. + + Values are represented in thousandths of Volts (mV). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigLVDEntry 5 } + +dm3ConfigLVDOpenAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the LVD Open Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + ::= { dm3ConfigLVDEntry 6 } + +dm3ConfigLVDHWAlarm OBJECT-TYPE +SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the LVD Hardware Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + ::= { dm3ConfigLVDEntry 7 } + + +-- the dm3ConfigBattery group + +dm3ConfigBattFloatVolt OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Battery Float Voltage. This setting controls the power plant voltage. + + Values are represented in thousandths of Volts (mV). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigBattery 1 } + +dm3ConfigBattMaxRecharge OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Battery Maximum Recharge Rate. This setting controls the battery max + recharge rate. The value is based on C/20 for 240 AHr battery string. + + Values are represented in thousandths of Amps (mA). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigBattery 2 } + +dm3ConfigBattDischargeThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Battery discharge threshold. If battery output current exceeds threshold + a battery discharge alarm will occur. + + Values are represented in thousandths of Amps (mA). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigBattery 3 } + +dm3ConfigBattDischargeAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Battery Discharge Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigBattery 4 } + +dm3ConfigBattHighVoltThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Battery high voltage threshold. If system battery voltage exceeds threshold + a battery high voltage alarm will occur. + + Values are represented in thousandths of Volts (mV). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigBattery 5 } + +dm3ConfigBattHighVoltAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Battery High Voltage Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigBattery 6 } + +dm3ConfigBattLowVoltThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Battery low voltage threshold. If system battery voltage is under threshold + a battery low voltage alarm will occur. + + Values are represented in thousandths of Volts (mV). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigBattery 7 } + +dm3ConfigBattLowVoltAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Battery Low Voltage Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigBattery 8 } + +dm3ConfigBattHighTempThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Battery high temperature threshold. If system battery temperature exceeds threshold + a battery high temperature alarm will occur. + + Values are represented in thousandths of a degree. + Units are displayed in the scale shown in + the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). + + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + + ::= { dm3ConfigBattery 9 } + +dm3ConfigBattHighTempAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Battery High Temperature Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigBattery 10 } + +dm3ConfigBattLowTempThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Battery low temperature threshold. If system battery temperature is under threshold + a battery low temperature alarm will occur. + + Values are represented in thousandths of a degree. + Units are displayed in the scale shown in + the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). + + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + + ::= { dm3ConfigBattery 11 } + +dm3ConfigBattLowTempAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Battery Low Temperature Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigBattery 12 } + +dm3ConfigBattAmpHour OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Battery Amp-Hour Size. Units are thousandths of Amp hours (mAHr). + + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigBattery 13 } + +dm3ConfigCompMethod OBJECT-TYPE + SYNTAX INTEGER { + tempcompOn (1), + tempcompOff (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This OID is used to configure and get the state of the battery + temperature compensation. + + Setting this OID to tempcompOn (1) will enable/turn on the battery temperature compensation. + Setting this OID to tempcompOff (2) will disable/turn off the battery temperature compensation." + ::= { dm3ConfigBattery 14 } + +dm3ConfigCompTempCoeff OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compensation Temperature Coefficient. (uV/degC/cell). + + Units are presented in microvolts. + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigBattery 15 } + +dm3ConfigHighKneeTemp OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "High Knee for temperature compensation: Compensation temperature coefficient + becomes 0mV/degC/cell. + + Values are represented in thousandths of degrees Celsius. + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigBattery 16 } + +dm3ConfigLowKneeTemp OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Low Knee for temperature compensation: Compensation temperature coefficient + becomes 0mV/degC/cell. + + Values are represented in thousandths of degrees Celsius. + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigBattery 17 } + +dm3ConfigBattHwCurrentAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Battery Current Hardware Alarm (indicating current is outside realistic + limits, or a possible measurement fault; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigBattery 18 } + +dm3ConfigBattHwTempAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Battery Temperature Hardware Alarm (indicating temperature is outside realistic + limits, or a possible measurement fault; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigBattery 19 } + + +-- the dm3ConfigRectThresh group +dm3ConfigRectHighVoltThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Rectifier high voltage threshold. If rectifier voltage exceeds threshold + a rectifier high voltage alarm will occur. + + Values are represented in thousandths of Volts (mV). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigRectThresh 1 } + + +dm3ConfigRectLowVoltThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Rectifier low voltage threshold. If rectifier voltage is under threshold + a rectifier low voltage alarm will occur. + + Values are represented in thousandths of Volts (mV). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigRectThresh 2 } + +dm3ConfigRectFailSafe OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Rectifier Fail Safe point. This OID represents the value sent to rectifier controllers + to use in the event of communications loss with the Master Controller or Master Controller + board failure. + + Values are represented in thousandths of Volts (mV). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigRectThresh 3 } + +dm3ConfigRectFailComm OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Rectifier Communication Fail timeout. This OID represents the time interval in which there is no + communication between the rectifier and the master controller at which the rectifier will reset + all its values to default. + + Values are represented in hundredths of Seconds. + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigRectThresh 4 } + +-- the dm3ConfigRectAlarms group + +dm3ConfigRectHighVoltAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Rectifier High Voltage Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigRectAlarms 1 } + +dm3ConfigRectLowVoltAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Rectifier Low Voltage Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigRectAlarms 2 } + +dm3ConfigRectConfigAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This alarm is activated when a new rectifier is detected; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigRectAlarms 3 } + +dm3ConfigRect1ofNAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This setting indicates the action if ONE rectifier of a N+1 system has failed; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigRectAlarms 4 } + +dm3ConfigRect2ofNAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This setting indicates the action if TWO OR MORE rectifiers of a N+1 system have failed; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigRectAlarms 5 } + +dm3ConfigRectDiagAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9), + alarmNofN (10) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Rectifier Controller Diagnostics Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition. + Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID + to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the + dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system." + + ::= { dm3ConfigRectAlarms 6 } + +dm3ConfigRectImbalanceAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Rectifier Imbalance Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigRectAlarms 7 } + +dm3ConfigRectCurrLimitAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9), + alarmNofN (10) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Rectifier Current Limit Alarm (indicating rectifier in the Current Limit state); + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition. + Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID + to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the + dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system." + + ::= { dm3ConfigRectAlarms 8 } + +dm3ConfigRectStandbyAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9), + alarmNofN (10) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Rectifier Standby Alarm (indicating output DC has been turned off); + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition. + Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID + to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the + dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system." + + ::= { dm3ConfigRectAlarms 9 } + +dm3ConfigRectFanFailAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9), + alarmNofN (10) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Rectifier Fan Fail Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition. + Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID + to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the + dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system." + + ::= { dm3ConfigRectAlarms 10 } + +dm3ConfigRectFailAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9), + alarmNofN (10) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Rectifier Fail Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition. + Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID + to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the + dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system." + + ::= { dm3ConfigRectAlarms 11 } + +dm3ConfigRectHwVoltAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Rectifier Hardware Voltage Alarm (indicating voltage outside realistic limits, + or a possible measurement fault); + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigRectAlarms 12 } + + +-- the dm3ConfigConvThresh group + +dm3ConfigConvHighVoltThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Converter high voltage threshold. If converter voltage exceeds threshold + a converter high voltage alarm will occur. + + Values are represented in thousandths of Volts (mV). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + + ::= { dm3ConfigConvThresh 1 } + +dm3ConfigConvLowVoltThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Converter low voltage threshold. If converter voltage exceeds threshold + a converter low voltage alarm will occur. + + Values are represented in thousandths of Volts (mV). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigConvThresh 2 } + +dm3ConfigConvFailSafe OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Converter Fail Safe point. This OID represents the value sent to converter controllers + to use in the event of communications loss with the Master Controller or Master Controller + board failure. + + Values are represented in thousandths of Volts (mV). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigConvThresh 3 } + +dm3ConfigConvSetPoint OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Converter Set point. This OID represents the initial set point used in the + voltage control loop. + + Units are thousandths of Volts (mV). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigConvThresh 4 } + +dm3ConfigConvFailMax OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Converter Fail Maximum limit. This OID represents the value sent to the converter + controllers to define the maximum set point allowed. + + Units are thousandths of Volts (mV). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigConvThresh 5 } + +dm3ConfigConvFailMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Converter Fail Minimum limit. This OID represents the value sent to the converter + controllers to define the minimum set point allowed. + + Units are thousandths of Volts (mV). + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigConvThresh 6 } + +dm3ConfigConvFailComm OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Converter Communication Fail timeout. This OID represents the time interval in which there is no + communication between the converter and the master controller at which the converter will reset + all its values to default. + + Values are represented in hundredths of Seconds. + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigConvThresh 7 } + +-- the dm3ConfigConvAlarms group +dm3ConfigConvHighVoltAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Converter High Voltage Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigConvAlarms 1 } + +dm3ConfigConvLowVoltAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Converter Low Voltage Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigConvAlarms 2 } + +dm3ConfigConvConfigAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Converter Configuration Alarm (indicating a new converter has been detected); + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigConvAlarms 3 } + +dm3ConfigConv1ofNAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Converter 1ofN Alarm (indicating action if ONE converter of a N+1 system has failed); + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigConvAlarms 4 } + +dm3ConfigConv2ofNAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Converter 2ofN Alarm (indicating action if TWO OR MORE converters of a N+1 system has failed); + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigConvAlarms 5 } + +dm3ConfigConvDiagAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9), + alarmNofN (10) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Converter Diagnostics Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition. + Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID + to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the + dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system." + + ::= { dm3ConfigConvAlarms 6 } + +dm3ConfigConvImbalanceAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9), + alarmNofN (10) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Converter Imbalance Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition. + Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID + to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the + dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system." + + ::= { dm3ConfigConvAlarms 7 } + +dm3ConfigConvCurrLimitAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9), + alarmNofN (10) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Converter Current Limit Alarm (indicating the converter is in the Current Limit state); + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition. + Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID + to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the + dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system." + + ::= { dm3ConfigConvAlarms 8 } + +dm3ConfigConvStandbyAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9), + alarmNofN (10) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Converter Standby Alarm (indicating the converter is in the Standby state); + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition. + Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID + to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the + dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system." + + ::= { dm3ConfigConvAlarms 9 } + +dm3ConfigConvFanFailAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9), + alarmNofN (10) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Converter Fan Fail Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition. + Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID + to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the + dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system." + + ::= { dm3ConfigConvAlarms 10 } + +dm3ConfigConvFailAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9), + alarmNofN (10) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Converter Fail Alarm; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition. + Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID + to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the + dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system." + + ::= { dm3ConfigConvAlarms 11 } + +dm3ConfigConvHwVoltAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9), + alarmNofN (10) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "For the Converter Voltage Alarm (indicating voltage outside realistic limits, or a + possible measurement fault); + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition. + Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID + to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the + dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system." + + ::= { dm3ConfigConvAlarms 12 } + + +-- the dm3ConfigOutputRelays group + +dm3ConfigOutRlyTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant Output Relays controllable + by this IP address." + ::= { dm3ConfigOutputRelays 1 } + +dm3ConfigOutRlyTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dm3ConfigOutRlyEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for accessing settings of the Output Relays. The number of + entries is contained in the dm3ConfigOutRlyTableSize OID." + ::= { dm3ConfigOutputRelays 2 } + +dm3ConfigOutRlyEntry OBJECT-TYPE + SYNTAX Dm3ConfigOutRlyEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The output relay to configure." + INDEX { dm3ConfigOutRlyIndex } + ::= { dm3ConfigOutRlyTable 1 } + +Dm3ConfigOutRlyEntry ::= + SEQUENCE { + dm3ConfigOutRlyIndex INTEGER, + dm3ConfigOutRlyName DisplayString, + dm3ConfigOutRlyDelay INTEGER, + dm3ConfigOutRlyAlarm INTEGER + } + +dm3ConfigOutRlyIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant output relay." + ::= { dm3ConfigOutRlyEntry 1 } + +dm3ConfigOutRlyName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the output relay. The maximum value is 16 characters." + ::= { dm3ConfigOutRlyEntry 2 } + +dm3ConfigOutRlyDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output Relay Delay. This OID represents the time delay from the initiation of an + output relay action to when the output relay action does occur. If the alarm condition + disappears before the end of the delay, no action will occur. Delay for Major + and Minor alarms is not configurable and is always set to 0. + + Values are represented in hundredths of seconds. + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigOutRlyEntry 3 } + +dm3ConfigOutRlyAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output Relay Alarm. This setting indicates what action to perform in the event of + an output relay alarm condition; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition. + + Relay Alarm for Major and Minor alarms is not configurable and is always set to + alarmMajor and alarmMinor respectively." + + ::= { dm3ConfigOutRlyEntry 4 } + + +-- the dm3ConfigInputRelays group + +dm3ConfigInRlyTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant Input Relays controllable + by this IP address." + ::= { dm3ConfigInputRelays 1 } + +dm3ConfigInRlyTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dm3ConfigInRlyEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for accessing settings of the Input Relays. The number of + entries is contained in the dm3ConfigInRlyTableSize OID." + ::= { dm3ConfigInputRelays 2 } + +dm3ConfigInRlyEntry OBJECT-TYPE + SYNTAX Dm3ConfigInRlyEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The input relay to configure." + INDEX { dm3ConfigInRlyIndex } + ::= { dm3ConfigInRlyTable 1 } + +Dm3ConfigInRlyEntry ::= + SEQUENCE { + dm3ConfigInRlyIndex INTEGER, + dm3ConfigInRlyName DisplayString, + dm3ConfigInRlyDelay INTEGER, + dm3ConfigInRlyAlarm INTEGER + } + +dm3ConfigInRlyIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant input relay." + ::= { dm3ConfigInRlyEntry 1 } + +dm3ConfigInRlyName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the input relay. The maximum value is 16 characters." + + ::= { dm3ConfigInRlyEntry 2 } + +dm3ConfigInRlyDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input Relay Delay. This OID represents the time delay from the initiation of an + input relay action to when the input relay action does occur. If the alarm condition + disappears before the end of the delay, no action will occur. + + Values are represented in hundredths of seconds. + + Attempts to set the value above or below the acceptable range of the powerplant + will cause the value to be set at the high or low point of the range respectively." + ::= { dm3ConfigInRlyEntry 3 } + +dm3ConfigInRlyAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input Relay Alarm. This setting indicates what action to perform in the event of + an input relay alarm condition; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigInRlyEntry 4 } + +-- the dm3ConfigBreakers group + +dm3ConfigBreakersTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant circuit breakers controllable + by this IP address." + ::= { dm3ConfigBreakers 1 } + +dm3ConfigBreakersTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dm3ConfigBreakersEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for accessing settings of the circuit breakers. The number of + entries is contained in the dm3ConfigBreakersTableSize OID." + ::= { dm3ConfigBreakers 2 } + +dm3ConfigBreakersEntry OBJECT-TYPE + SYNTAX Dm3ConfigBreakersEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The circuit breaker to configure." + INDEX { dm3ConfigBreakersIndex } + ::= { dm3ConfigBreakersTable 1 } + +Dm3ConfigBreakersEntry ::= + SEQUENCE { + dm3ConfigBreakersIndex INTEGER, + dm3ConfigBreakersName DisplayString, + dm3ConfigBreakersAlarm INTEGER + } + +dm3ConfigBreakersIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant circuit breaker." + ::= { dm3ConfigBreakersEntry 1 } + +dm3ConfigBreakersName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the circuit breaker. The maximum value is 16 characters." + ::= { dm3ConfigBreakersEntry 2 } + +dm3ConfigBreakersAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Circuit Breaker Alarm. This setting indicates what action to perform in the event of + a circuit breaker alarm condition; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigBreakersEntry 3 } + +-- the dm3ConfigFuses group + +dm3ConfigFusesTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant Fuses controllable + by this IP address." + ::= { dm3ConfigFuses 1 } + +dm3ConfigFusesTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dm3ConfigFusesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for accessing settings of the Fuses. The number of + entries is contained in the dm3ConfigFusesTableSize OID." + ::= { dm3ConfigFuses 2 } + +dm3ConfigFusesEntry OBJECT-TYPE + SYNTAX Dm3ConfigFusesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The fuse to configure." + INDEX { dm3ConfigFusesIndex } + ::= { dm3ConfigFusesTable 1 } + +Dm3ConfigFusesEntry ::= + SEQUENCE { + dm3ConfigFusesIndex INTEGER, + dm3ConfigFusesName DisplayString, + dm3ConfigFusesAlarm INTEGER + } + +dm3ConfigFusesIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant fuse." + ::= { dm3ConfigFusesEntry 1 } + +dm3ConfigFusesName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the fuse. The maximum value is 16 characters." + ::= { dm3ConfigFusesEntry 2 } + +dm3ConfigFusesAlarm OBJECT-TYPE + SYNTAX INTEGER { + alarmIgnore (1), + alarmRelay1 (2), + alarmRelay2 (3), + alarmRelay3 (4), + alarmRelay4 (5), + alarmRelay5 (6), + alarmRelay6 (7), + alarmMinor (8), + alarmMajor (9) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Fuses Alarm. This setting indicates what action to perform in the event of + a Fuse alarm condition; + Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. + Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an + alarm condition. + Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an + alarm condition. + Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an + alarm condition. + Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an + alarm condition. + Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an + alarm condition. + Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an + alarm condition. + Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an + alarm condition. + Setting this OID to alarmMajor (9) causes the Major relay to be activated for an + alarm condition." + + ::= { dm3ConfigFusesEntry 3 } + +-- the dm3StatusSystem group + +dm3StatusSystemTemp OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "System temperature based on sensor on Master Controller PCB. + + Values are represented in thousandths of a degree. + Units are displayed in the scale shown in + the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit)." + + ::= { dm3StatusSystem 1 } + +dm3StatusSystemStart OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Time stamp at DC powerplant initialization. + The time is represented as MMM,DD,YYYY,HH:MM:SS." + ::= { dm3StatusSystem 2 } + +dm3StatusSysRemoteAccess OBJECT-TYPE + SYNTAX INTEGER { + accessEnabled (1), + accessDisabled (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Remote Access indicator + This setting indicates if configuration (write) access to the powerplant is enabled or + disabled at the powerplant level. + This value will be accessEnabled (1) if remote configuration is enabled, and + accessDisabled (2) if remote configuration is disabled." + ::= { dm3StatusSystem 3 } + +dm3StatusSysSecurityLevel OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable shows the current active security access level of controller. This + can only be changed directly from the front panel." + ::= { dm3StatusSystem 4 } + +dm3StatusSysTempSanity OBJECT-TYPE + SYNTAX INTEGER{ + saneYES (1), + saneNO (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "System temperature sanity indicator. Indicates if the system temperature is + reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) + indicates temperature is reasonable, a value of saneNo (2) indicates it is not." + ::= { dm3StatusSystem 5 } + +dm3StatusSysAlarmState OBJECT-TYPE + SYNTAX INTEGER{ + alarmMinor (1), + alarmMajor (2), + alarmBoth (3), + alarmNone (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "System Alarm State. Reflects the alarm status of the overall DC system. + If a minor alarm is present, the value will be alarmMinor(1). + If a major alarm is present, the value will be alarmMajor(2). + If both minor and a major alarm is present, the value will be alarmBoth(3). + If no alarm is present, the value will be alarmNone(4)." + ::= { dm3StatusSystem 6 } + +dm3StatusSysTempUnits OBJECT-TYPE + SYNTAX INTEGER { + celsius(1), + fahrenheit(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature scale used to display the temperature + in the DC system, Celsius(1) or Fahrenheit(2). + This setting is based on the system preferences + configuration in the agent." + ::= { dm3StatusSystem 7 } + + +-- the dm3StatusAlarms group + +dm3StatusAlarmsTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant alarms viewable + by this IP address." + ::= { dm3StatusAlarms 1 } + +dm3StatusAlarmsTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dm3StatusAlarmsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for accessing system alarms. The number of + entries is contained in the dm3StatusAlarmsTableSize OID." + ::= { dm3StatusAlarms 2 } + +dm3StatusAlarmsEntry OBJECT-TYPE + SYNTAX Dm3StatusAlarmsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The alarm to display." + INDEX { dm3StatusAlarmsIndex } + ::= { dm3StatusAlarmsTable 1 } + +Dm3StatusAlarmsEntry ::= + SEQUENCE { + dm3StatusAlarmsIndex INTEGER, + dm3StatusAlarmsText DisplayString + } + +dm3StatusAlarmsIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the system alarm." + ::= { dm3StatusAlarmsEntry 1 } + +dm3StatusAlarmsText OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The 16 character text describing the active alarm condition." + ::= { dm3StatusAlarmsEntry 2 } + +-- the dm3StatusBattery group + +dm3StatusBattCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Battery Current: This OID shows the battery current in thousandths of Amps (mA)." + ::= { dm3StatusBattery 1 } + +dm3StatusBattTemp OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Battery Temperature: + + Values are represented in thousandths of a degree. + Units are displayed in the scale shown in + the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit)." + + ::= { dm3StatusBattery 2 } + +dm3StatusBattCurrentSanity OBJECT-TYPE + SYNTAX INTEGER{ + saneYES (1), + saneNO (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Battery current sanity indicator. Indicates if the battery current is + reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) + indicates current is reasonable, a value of saneNo (2) indicates it is not." + ::= { dm3StatusBattery 3 } + +dm3StatusBattTempSanity OBJECT-TYPE + SYNTAX INTEGER{ + saneYES (1), + saneNO (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Battery temperature sanity indicator. Indicates if the battery temperature is + reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) + indicates temperature is reasonable, a value of saneNo (2) indicates it is not." + ::= { dm3StatusBattery 4 } + +-- the dm3StatusOEM group + +dm3StatusOEMrectOffset OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the rectifier offset value in thousandths of Volts (mV)." + ::= { dm3StatusOEM 1 } + +dm3StatusOEMrectGain OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the rectifier gain value in thousandths of Volts (mV/V)." + ::= { dm3StatusOEM 2 } + +dm3StatusOEMconvOffset OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the converter offset value in thousandths of Volts (mV)." + ::= { dm3StatusOEM 3 } + +dm3StatusOEMconvGain OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the converter gain value in thousandths of Volts (mV/V)." + ::= { dm3StatusOEM 4 } + +dm3StatusOEMshuntOffset OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the shunt offset value in thousandths of Amps (mA)." + ::= { dm3StatusOEM 5 } + +dm3StatusOEMshuntGain OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the shunt gain value in thousandths of Amps (mA/A)." + ::= { dm3StatusOEM 6 } + +-- the dm3StatusLVD group + +dm3StatusLVDTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant LVDs viewable + by this IP address." + ::= { dm3StatusLVD 1 } + +dm3StatusLVDTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dm3StatusLVDEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for accessing settings of the LVDs. The number of + entries is contained in the dm3StatusLVDTableSize OID." + ::= { dm3StatusLVD 2 } + +dm3StatusLVDEntry OBJECT-TYPE + SYNTAX Dm3StatusLVDEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The LVD to gather status from." + INDEX { dm3StatusLVDIndex } + ::= { dm3StatusLVDTable 1 } + +Dm3StatusLVDEntry ::= + SEQUENCE { + dm3StatusLVDIndex INTEGER, + dm3StatusLVDName DisplayString, + dm3StatusLVDState INTEGER, + dm3StatusLVDHwFault INTEGER + } + +dm3StatusLVDIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant LVD." + ::= { dm3StatusLVDEntry 1 } + +dm3StatusLVDName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the LVD. The maximum size is + 16 characters. The name is set by using the + dm3ConfigLVDName OID. + This OID is provided for informational purposes only." + ::= { dm3StatusLVDEntry 2 } + +dm3StatusLVDState OBJECT-TYPE + SYNTAX INTEGER { + statusClosed (1), + statusOpened (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusClosed (1) if the LVD is closed. + statusOpened (2) will be returned if the LVD is opened." + ::= { dm3StatusLVDEntry 3 } + +dm3StatusLVDHwFault OBJECT-TYPE + SYNTAX INTEGER { + statusFault (1), + statusNofault (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusFault (1) if the LVD is faulted. + statusNofault (2) will be returned if the LVD is not faulted." + ::= { dm3StatusLVDEntry 4 } + +-- the dm3StatusRectifier group + +dm3StatusRectTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant rectifiers viewable + by this IP address." + ::= { dm3StatusRectifier 1 } + +dm3StatusRectTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dm3StatusRectEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for accessing settings of the rectifiers. The number of + entries is contained in the dm3StatusRectTableSize OID." + ::= { dm3StatusRectifier 2 } + +dm3StatusRectEntry OBJECT-TYPE + SYNTAX Dm3StatusRectEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The rectifier to gather status from." + INDEX { dm3StatusRectIndex } + ::= { dm3StatusRectTable 1 } + +Dm3StatusRectEntry ::= + SEQUENCE { + dm3StatusRectIndex INTEGER, + dm3StatusRectID INTEGER, + dm3StatusRectDesc DisplayString, + dm3StatusRectCurrent INTEGER, + dm3StatusRectCurrentLimit INTEGER, + dm3StatusRectStandby INTEGER, + dm3StatusRectFanFail INTEGER, + dm3StatusRectFail INTEGER, + dm3StatusRectDevType INTEGER, + dm3StatusRectPhyAddr INTEGER, + dm3StatusRectCfg INTEGER, + dm3StatusRectPcbRev INTEGER, + dm3StatusRectFwVer INTEGER, + dm3StatusRectPresent INTEGER, + dm3StatusRectDiagPass INTEGER, + dm3StatusRectState INTEGER + } + +dm3StatusRectIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant rectifier." + ::= { dm3StatusRectEntry 1 } + +dm3StatusRectID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the rectifier ID. This enumerates the number of the rectifier within + a group of rectifiers." + ::= { dm3StatusRectEntry 2 } + +dm3StatusRectDesc OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the 16-character rectifier description." + ::= { dm3StatusRectEntry 3 } + +dm3StatusRectCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the rectifier current in thousandths of Amps (mA)." + ::= { dm3StatusRectEntry 4 } + +dm3StatusRectCurrentLimit OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the rectifier is in the Current Limit state. + statusFalse (2) will be returned if the rectifier is not in the Current Limit state." + ::= { dm3StatusRectEntry 5 } + +dm3StatusRectStandby OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the rectifier is in the Standby state. + statusFalse (2) will be returned if the rectifier is not in the Standby state." + ::= { dm3StatusRectEntry 6 } + +dm3StatusRectFanFail OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the rectifier Fan has failed. + statusFalse (2) will be returned if the rectifier Fan has not failed." + ::= { dm3StatusRectEntry 7 } + +dm3StatusRectFail OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the rectifier has failed. + statusFalse (2) will be returned if the rectifier has not failed." + ::= { dm3StatusRectEntry 8 } + +dm3StatusRectDevType OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the rectifier device type." + ::= { dm3StatusRectEntry 9 } + +dm3StatusRectPhyAddr OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the rectifier physical address (the address on the bus)." + ::= { dm3StatusRectEntry 10 } + +dm3StatusRectCfg OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the rectifier is present after + power-up or set-configuration. + statusFalse (2) will be returned if the rectifier is not configured." + ::= { dm3StatusRectEntry 11 } + +dm3StatusRectPcbRev OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the rectifier device PCB serial number." + ::= { dm3StatusRectEntry 12 } + +dm3StatusRectFwVer OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the rectifier device firmware revision." + ::= { dm3StatusRectEntry 13 } + +dm3StatusRectPresent OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the rectifier is present. + statusFalse (2) will be returned if the rectifier is not present." + ::= { dm3StatusRectEntry 14 } + +dm3StatusRectDiagPass OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the rectifier diagnostics have passed. + statusFalse (2) will be returned if the rectifier diagnostics have not passed." + ::= { dm3StatusRectEntry 15 } + +dm3StatusRectState OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the rectifier device state as defined by the device status register." + ::= { dm3StatusRectEntry 16 } + +dm3StatusSysRectVoltSanity OBJECT-TYPE + SYNTAX INTEGER { + saneYES (1), + saneNO (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Rectifier voltage sanity indicator. Indicates if the rectifier voltage is + reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) + indicates voltage is reasonable, a value of saneNo (2) indicates it is not." + ::= { dm3StatusRectifier 3 } + +dm3StatusSysRectAvailable OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the rectifier is available. + statusFalse (2) will be returned if the rectifier is not available." + ::= { dm3StatusRectifier 4 } + +dm3StatusSysRectType OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the type of rectifier the system has. There can only be a single type of + rectifier in the power plant" + ::= { dm3StatusRectifier 5 } + +dm3StatusSysRectVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the system level rectifier voltage in thousandths of Volts (mV)." + ::= { dm3StatusRectifier 6 } + +dm3StatusSysRectCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the system level rectifier current in thousandths of Amps (mA)." + ::= { dm3StatusRectifier 7 } + + +-- the dm3StatusConverter group + +dm3StatusConvTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant converters viewable + by this IP address." + ::= { dm3StatusConverter 1 } + +dm3StatusConvTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dm3StatusConvEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for viewing status of the converters. The number of + entries is contained in the dm3StatusConvTableSize OID." + ::= { dm3StatusConverter 2 } + +dm3StatusConvEntry OBJECT-TYPE + SYNTAX Dm3StatusConvEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The converter to gather status from." + INDEX { dm3StatusConvIndex } + ::= { dm3StatusConvTable 1 } + +Dm3StatusConvEntry ::= + SEQUENCE { + dm3StatusConvIndex INTEGER, + dm3StatusConvID INTEGER, + dm3StatusConvDesc DisplayString, + dm3StatusConvCurrent INTEGER, + dm3StatusConvCurrentLimit INTEGER, + dm3StatusConvStandby INTEGER, + dm3StatusConvFanFail INTEGER, + dm3StatusConvFail INTEGER, + dm3StatusConvDevType INTEGER, + dm3StatusConvPhyAddr INTEGER, + dm3StatusConvCfg INTEGER, + dm3StatusConvPcbRev INTEGER, + dm3StatusConvFwVer INTEGER, + dm3StatusConvPresent INTEGER, + dm3StatusConvDiagPass INTEGER, + dm3StatusConvState INTEGER + } + +dm3StatusConvIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant converter." + ::= { dm3StatusConvEntry 1 } + +dm3StatusConvID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the converter ID. This enumerates the number of the converter within + a group of converters." + ::= { dm3StatusConvEntry 2 } + +dm3StatusConvDesc OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the 16 character converter description." + ::= { dm3StatusConvEntry 3 } + +dm3StatusConvCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the converter current in thousandths of Amps (mA)." + ::= { dm3StatusConvEntry 4 } + +dm3StatusConvCurrentLimit OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the converter is in the Current Limit state. + statusFalse (2) will be returned if the converter is not in the Current Limit state." + ::= { dm3StatusConvEntry 5 } + +dm3StatusConvStandby OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the converter is in the Standby state. + statusFalse (2) will be returned if the converter is not in the Standby state." + ::= { dm3StatusConvEntry 6 } + +dm3StatusConvFanFail OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the converter Fan has failed. + statusFalse (2) will be returned if the converter Fan has not failed." + ::= { dm3StatusConvEntry 7 } + +dm3StatusConvFail OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the converter has failed. + statusFalse (2) will be returned if the converter has not failed." + ::= { dm3StatusConvEntry 8 } + +dm3StatusConvDevType OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the converter device type." + ::= { dm3StatusConvEntry 9 } + +dm3StatusConvPhyAddr OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the converter physical address (the address on the bus)." + ::= { dm3StatusConvEntry 10 } + +dm3StatusConvCfg OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the converter is present after + power-up or set-configuration. + statusFalse (2) will be returned if the converter is not configured." + ::= { dm3StatusConvEntry 11 } + +dm3StatusConvPcbRev OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the converter device PCB serial number." + ::= { dm3StatusConvEntry 12 } + +dm3StatusConvFwVer OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the converter device firmware version." + ::= { dm3StatusConvEntry 13 } + +dm3StatusConvPresent OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the converter is present. + statusFalse (2) will be returned if the converter is not present." + ::= { dm3StatusConvEntry 14 } + +dm3StatusConvDiagPass OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the converter diagnostics have passed. + statusFalse (2) will be returned if the converter diagnostics have not passed." + ::= { dm3StatusConvEntry 15 } + +dm3StatusConvState OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the converter state as defined by the device status register." + ::= { dm3StatusConvEntry 16 } + +dm3StatusSysConvVoltSanity OBJECT-TYPE + SYNTAX INTEGER{ + saneYES (1), + saneNO (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Converter voltage sanity indicator. Indicates if the converter voltage is + reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) + indicates voltage is reasonable, a value of saneNo (2) indicates it is not." + ::= { dm3StatusConverter 3 } + +dm3StatusSysConvAvailable OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the converter is available. + statusFalse (2) will be returned if the converter is not available." + ::= { dm3StatusConverter 4 } + +dm3StatusSysConvType OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the converter type." + ::= { dm3StatusConverter 5 } + +dm3StatusSysConvVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the system level converter voltage in thousandths of volts (mV)." + ::= { dm3StatusConverter 6 } + +dm3StatusSysConvCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the system level converter current in thousandths of Amps (mA)." + ::= { dm3StatusConverter 7 } + +-- the dm3StatusOutputRelays group + +dm3StatusOutRlyTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant output relays viewable + by this IP address." + ::= { dm3StatusOutputRelays 1 } + +dm3StatusOutRlyTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dm3StatusOutRlyEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for viewing status of the output relays. The number of + entries is contained in the dm3StatusOutRlyTableSize OID." + ::= { dm3StatusOutputRelays 2 } + +dm3StatusOutRlyEntry OBJECT-TYPE + SYNTAX Dm3StatusOutRlyEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The output relay to gather status from." + INDEX { dm3StatusOutRlyIndex } + ::= { dm3StatusOutRlyTable 1 } + +Dm3StatusOutRlyEntry ::= + SEQUENCE { + dm3StatusOutRlyIndex INTEGER, + dm3StatusOutRlyName DisplayString, + dm3StatusOutRlyStatus INTEGER + } + +dm3StatusOutRlyIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant output relay." + ::= { dm3StatusOutRlyEntry 1 } + +dm3StatusOutRlyName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the output relay. The maximum size is + 16 characters. The name is set by using the + dm3ConfigOutRlyName OID. + This OID is provided for informational purposes only." + ::= { dm3StatusOutRlyEntry 2 } + +dm3StatusOutRlyStatus OBJECT-TYPE + SYNTAX INTEGER { + statusOn (1), + statusOff (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusOn (1) if the output relay is enabled/on. + statusOff (2) will be returned if the output relay is disabled/off." + ::= { dm3StatusOutRlyEntry 3 } + + +-- the dm3StatusInputRelays group + +dm3StatusInRlyTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant input relays viewable + by this IP address." + ::= { dm3StatusInputRelays 1 } + +dm3StatusInRlyTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dm3StatusInRlyEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for viewing status of the input relays. The number of + entries is contained in the dm3StatusInRlyTableSize OID." + ::= { dm3StatusInputRelays 2 } + + +dm3StatusInRlyEntry OBJECT-TYPE + SYNTAX Dm3StatusInRlyEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The input relays to gather status from." + INDEX { dm3StatusInRlyIndex } + ::= { dm3StatusInRlyTable 1 } + +Dm3StatusInRlyEntry ::= + SEQUENCE { + dm3StatusInRlyIndex INTEGER, + dm3StatusInRlyName DisplayString, + dm3StatusInRlyStatus INTEGER + } + +dm3StatusInRlyIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant input relay." + ::= { dm3StatusInRlyEntry 1 } + +dm3StatusInRlyName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the input relay. The maximum size is + 16 characters. The name is set by using the + dm3ConfigInRlyName OID. + This OID is provided for informational purposes only." + ::= { dm3StatusInRlyEntry 2 } + +dm3StatusInRlyStatus OBJECT-TYPE + SYNTAX INTEGER { + statusOn (1), + statusOff (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusOn (1) if the input relay is enabled/on. + statusOff (2) will be returned if the input relay is disabled/off." + ::= { dm3StatusInRlyEntry 3 } + +-- the dm3StatusBreakers group + +dm3StatusBreakersTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant circuit breakers viewable + by this IP address." + ::= { dm3StatusBreakers 1 } + +dm3StatusBreakersTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dm3StatusBreakersEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for viewing status of the circuit breakers. The number of + entries is contained in the dm3StatusBreakersTableSize OID." + ::= { dm3StatusBreakers 2 } + +dm3StatusBreakersEntry OBJECT-TYPE + SYNTAX Dm3StatusBreakersEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The circuit breaker to gather status from." + INDEX { dm3StatusBreakersIndex } + ::= { dm3StatusBreakersTable 1 } + +Dm3StatusBreakersEntry ::= + SEQUENCE { + dm3StatusBreakersIndex INTEGER, + dm3StatusBreakersName DisplayString, + dm3StatusBreakersStatus INTEGER + } + +dm3StatusBreakersIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant circuit breaker." + ::= { dm3StatusBreakersEntry 1 } + +dm3StatusBreakersName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the circuit breaker. The maximum size is + 16 characters. The name is set by using the + dm3ConfigBreakersName OID. + This OID is provided for informational purposes only." + ::= { dm3StatusBreakersEntry 2 } + +dm3StatusBreakersStatus OBJECT-TYPE + SYNTAX INTEGER { + statusClosed (1), + statusOpen (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusClosed (1) if the circuit breaker is closed. + statusOpen (2) will be returned if the circuit breaker is open." + ::= { dm3StatusBreakersEntry 3 } + +-- the dm3StatusFuses group + +dm3StatusFusesTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant fuses controllable + by this IP address." + ::= { dm3StatusFuses 1 } + +dm3StatusFusesTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dm3StatusFusesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for viewing status of the fuses. The number of + entries is contained in the dm3StatusFusesTableSize OID." + ::= { dm3StatusFuses 2 } + +dm3StatusFusesEntry OBJECT-TYPE + SYNTAX Dm3StatusFusesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The fuse to gather status from." + INDEX { dm3StatusFusesIndex } + ::= { dm3StatusFusesTable 1 } + +Dm3StatusFusesEntry ::= + SEQUENCE { + dm3StatusFusesIndex INTEGER, + dm3StatusFusesName DisplayString, + dm3StatusFusesStatus INTEGER + } + +dm3StatusFusesIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant fuse." + ::= { dm3StatusFusesEntry 1 } + +dm3StatusFusesName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the fuse. The maximum size is + 16 characters. The name is set by using the + dm3ConfigFuseName OID. + This OID is provided for informational purposes only." + ::= { dm3StatusFusesEntry 2 } + +dm3StatusFusesStatus OBJECT-TYPE + SYNTAX INTEGER { + statusClosed (1), + statusOpen (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusClosed (1) if the fuse is closed. + statusOpen (2) will be returned if the fuse is open." + ::= { dm3StatusFusesEntry 3 } + +-- the atsIdent group + +atsIdentHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the Automatic Transfer Switch. + This value is set at the factory." + ::= { atsIdent 1 } + +atsIdentFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A string identifying the Automatic Transfer Switch + firmware revision." + ::= { atsIdent 2 } + +atsIdentFirmwareDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date of release for this Automatic Transfer Switch + firmware revision. " + ::= { atsIdent 3 } + +atsIdentDateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date when the Automatic Transfer Switch was manufactured in mm/dd/yyyy format. + This value is set at the factory. " + ::= { atsIdent 4 } + +atsIdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A string identifying the model number of the Automatic Transfer Switch. + This value is set at the factory." + ::= { atsIdent 5 } + +atsIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A string identifying the serial number of + the Automatic Transfer Switch. This value is set at the factory." + ::= { atsIdent 6 } + +atsIdentNominalLineVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "RMS Utility Voltage measured in Volts." + ::= { atsIdent 7 } + +atsIdentNominalLineFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Utility Power Frequency measured in Hertz." + ::= { atsIdent 8 } + +atsIdentDeviceRating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This gives the device rating in Amps" + ::= { atsIdent 9 } + + +-- the atsCalibration group + +-- Input Voltage Calibration Factor table + + atsCalibrationNumInputs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of inputs to this device." + ::= { atsCalibrationInput 1 } + + atsCalibrationNumInputPhases OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of phases per input for this device." + ::= { atsCalibrationInput 2 } + + atsCalibrationInputPhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF ATSCalibrationInputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The number of phases per input line to this device." + ::= { atsCalibrationInput 3 } + + atsCalibrationInputPhaseEntry OBJECT-TYPE + SYNTAX ATSCalibrationInputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing calibration information applicable to a + particular input phase." + INDEX { atsCalibrationInputTableIndex, atsCalibrationInputPhaseTableIndex } + ::= { atsCalibrationInputPhaseTable 1 } + + ATSCalibrationInputPhaseEntry ::= SEQUENCE { + atsCalibrationInputTableIndex INTEGER, + atsCalibrationInputPhaseTableIndex INTEGER, + atsLineVoltageCalibrationFactor INTEGER + } + + atsCalibrationInputTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input identifier." + ::= { atsCalibrationInputPhaseEntry 1 } + + atsCalibrationInputPhaseTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input phase identifier." + ::= { atsCalibrationInputPhaseEntry 2 } + + atsLineVoltageCalibrationFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Line Voltage Calibration factor. + This value is set at the factory." + ::= { atsCalibrationInputPhaseEntry 3 } + +-- Power Supply Voltage Calibration table + + atsCalibrationPowerSupplyVoltages OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of power supply voltages supported by this device. + This variable indicates the number of rows in the + atsCalibrationPowerSupplyTable." + ::= { atsCalibrationPowerSupply 1 } + + atsCalibrationPowerSupplyVoltageTable OBJECT-TYPE + SYNTAX SEQUENCE OF ATSCalibrationPowerSupplyVoltageEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of Power Supply table entries." + ::= { atsCalibrationPowerSupply 2 } + + atsCalibrationPowerSupplyVoltageEntry OBJECT-TYPE + SYNTAX ATSCalibrationPowerSupplyVoltageEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular Power Supply Voltage." + INDEX { atsCalibrationPowerSupplyVoltageTableIndex } + ::= { atsCalibrationPowerSupplyVoltageTable 1 } + + ATSCalibrationPowerSupplyVoltageEntry ::= SEQUENCE { + atsCalibrationPowerSupplyVoltageTableIndex INTEGER, + atsCalibrationPowerSupplyVoltage INTEGER, + atsPowerSupplyVoltageCalibrationFactor INTEGER + } + + atsCalibrationPowerSupplyVoltageTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The power supply voltage identifier." + ::= { atsCalibrationPowerSupplyVoltageEntry 1 } + + atsCalibrationPowerSupplyVoltage OBJECT-TYPE + SYNTAX INTEGER { + powerSupply24V(1), + powerSupply12V(2), + powerSupply(3), + powerSupply24VSourceB(4), + powerSupplyMinus12V(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This value describes the power supply voltage of + 24V Source A, 24V Source B, +12V, -12V and 5V." + ::= { atsCalibrationPowerSupplyVoltageEntry 2 } + + atsPowerSupplyVoltageCalibrationFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The Line Voltage Calibration factor. + This value is set at the factory." + ::= { atsCalibrationPowerSupplyVoltageEntry 3 } + +-- Output Current Calibration table + + atsCalibrationNumOutputs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of output lines from this device. + This variable indicates the number of rows in the + atsCalibrationOutputTable." + ::= { atsCalibrationOutput 1 } + + atsCalibrationNumOutputPhases OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of output phases utilized in this + device." + ::= { atsCalibrationOutput 2 } + + atsCalibrationOutputTable OBJECT-TYPE + SYNTAX SEQUENCE OF ATSCalibrationOutputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of output table entries." + ::= { atsCalibrationOutput 3 } + + atsCalibrationOutputEntry OBJECT-TYPE + SYNTAX ATSCalibrationOutputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular output." + INDEX { atsCalibrationOutputTableIndex, atsCalibrationOutputPhasesTableIndex } + ::= { atsCalibrationOutputTable 1 } + + ATSCalibrationOutputEntry ::= SEQUENCE { + atsCalibrationOutputTableIndex INTEGER, + atsCalibrationOutputPhasesTableIndex INTEGER, + atsOutputCurrentCalibrationFactor INTEGER + } + + atsCalibrationOutputTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output identifier." + ::= { atsCalibrationOutputEntry 1 } + + atsCalibrationOutputPhasesTableIndex OBJECT-TYPE + SYNTAX INTEGER{ + phase1(1), + phase2(2), + phase3(3), + neutral(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of each calibration factor for each + output phase utilized in this device and one for neutral. " + ::= { atsCalibrationOutputEntry 2 } + + atsOutputCurrentCalibrationFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output current calibration factor measured in Amps." + ::= { atsCalibrationOutputEntry 3 } + + +-- the atsControl group + +atsControlResetATS OBJECT-TYPE + SYNTAX INTEGER { + none(1), + reset(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this variable will cause the Automatic Transfer Switch to + perform a power-on reset." + ::= { atsControl 1 } + +atsControlClearAllAlarms OBJECT-TYPE + SYNTAX INTEGER { + none(1), + clear(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this variable will clear all alarms in the Automatic Transfer Switch. + Returns (-1) if unsupported." + ::= { atsControl 2 } + + +-- the atsConfig group + +atsConfigProductName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A configurable character string." + ::= { atsConfig 1 } + +atsConfigPreferredSource OBJECT-TYPE + SYNTAX INTEGER { + sourceA(1), + sourceB(2), + none(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This variable returns the preferred source of power when both sources are OK." + ::= { atsConfig 2 } + +atsConfigFrontPanelLockout OBJECT-TYPE + SYNTAX INTEGER { + disableFrontPanel(1), + enableFrontPanel(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this variable to disableFrontPanel(1), prevents source + preference configuration of the Automatic Transfer Switch via the + Front Panel. + Setting this variable to enableFrontPanel(2)allows, source preference + configuration of the Automatic Transfer Switch via the Front Panel." + ::= { atsConfig 3 } + +atsConfigVoltageSensitivity OBJECT-TYPE + SYNTAX INTEGER { + high(1), + low(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This variable defines the sensitivity to changes in voltage: + high(1) for best protection, low(2) for frequent small line + voltage changes." + ::= { atsConfig 4 } + +atsConfigTransferVoltageRange OBJECT-TYPE + SYNTAX INTEGER { + wide(1), + medium(2), + narrow(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This variable defines the range of acceptable voltage from a power source. + If the voltage measured from the selected input source is not within this + range, the Automatic Transfer Switch will switch over (transfer) to the + alternate power source." + + ::= { atsConfig 5 } + +atsConfigCurrentLimit OBJECT-TYPE + SYNTAX INTEGER (0..20) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The threshold (in Amps) at which an Over Current Alarm will be generated. + This OID returns the overload threshold value of the + OID atsConfigPhaseOverLoadThreshold for the 1U ATS and + OID atsConfigBankOverLoadThreshold of total for the 2U ATS. + Setting this OID does not have any impact on the device." + ::= { atsConfig 6 } + + +atsConfigResetValues OBJECT-TYPE + SYNTAX INTEGER { + none(1), + reset(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Resets the ATS configuration to its default values. + Returns (-1) if not supported." + + ::= { atsConfig 7 } + +atsConfigLineVRMS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "To configure the input RMS voltage." + + ::= { atsConfig 8 } + +atsConfigLineVRMSNarrowLimit OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "To configure the Line VRMS Narrow Limit." + + ::= { atsConfig 9 } + +atsConfigLineVRMSMediumLimit OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "To configure the Line VRMS Medium Limit." + + ::= { atsConfig 10 } + +atsConfigLineVRMSWideLimit OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "To configure the Line VRMS Wide Limit." + + ::= { atsConfig 11 } + +atsConfigFrequencyDeviation OBJECT-TYPE + SYNTAX INTEGER { + one(1), + two(2), + three(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "To configure the frequency deviation." + + ::= { atsConfig 12 } + +-- Bank table + +atsConfigBankTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The size of the bank table." + ::= { atsConfig 13 } + + +atsConfigBankTable OBJECT-TYPE + SYNTAX SEQUENCE OF ATSConfigBankEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of each ATS bank." + ::= { atsConfig 14 } + +atsConfigBankEntry OBJECT-TYPE + SYNTAX ATSConfigBankEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This gives access to bank current threshold" + INDEX { atsConfigBankTableIndex } + ::= { atsConfigBankTable 1 } + +ATSConfigBankEntry ::= + SEQUENCE { + atsConfigBankTableIndex INTEGER, + atsConfigBank INTEGER, + atsConfigBankLowLoadThreshold INTEGER, + atsConfigBankNearOverLoadThreshold INTEGER, + atsConfigBankOverLoadThreshold INTEGER + } + +atsConfigBankTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index to the bank table entry." + ::= { atsConfigBankEntry 1 } + +atsConfigBank OBJECT-TYPE + SYNTAX INTEGER { + total (1), + bank1 (2), + bank2 (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The bank number of an ATS" + ::= { atsConfigBankEntry 2 } + +atsConfigBankLowLoadThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the current drawn is nearing + a low consumption condition. It is represented in Amps. + A warning will be issued when the load is less than the + threshold value. + + A threshold value of 0 Amps disables this warning. + + Maximum value must be less than the value returned + by the atsConfigBankNearOverLoadThreshold OID." + ::= { atsConfigBankEntry 3 } + +atsConfigBankNearOverLoadThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the current drawn is nearing + an overload condition. It is represented in Amps. + A warning will be issued when the load is greater than + or equal to the threshold value. + + Minimum value must be greater than the value returned by + the atsConfigBankLowLoadThreshold OID. + + Maximum value must be less than or equal to the value + returned by the atsConfigBankOverLoadThreshold OID." + ::= { atsConfigBankEntry 4 } + +atsConfigBankOverLoadThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the current drawn has entered + an overload condition. It is represented in Amps. + A warning will be issued when the load is greater than or + equal to the threshold value. + + Minimum value must be greater than or equal to the value + returned by the atsConfigBankNearOverLoadThreshold OID. + + Maximum value must be less than or equal to the value returned by + atsIdentDeviceRating OID." + ::= { atsConfigBankEntry 5 } + +-- Phase table + +atsConfigPhaseTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The size of the phase table." + ::= { atsConfig 15 } + + +atsConfigPhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF ATSConfigPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of each ATS phase." + ::= { atsConfig 16 } + +atsConfigPhaseEntry OBJECT-TYPE + SYNTAX ATSConfigPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This gives access to phase threshold" + INDEX { atsConfigPhaseTableIndex } + ::= { atsConfigPhaseTable 1 } + +ATSConfigPhaseEntry ::= + SEQUENCE { + atsConfigPhaseTableIndex INTEGER, + atsConfigPhase INTEGER, + atsConfigPhaseLowLoadThreshold INTEGER, + atsConfigPhaseNearOverLoadThreshold INTEGER, + atsConfigPhaseOverLoadThreshold INTEGER + } + +atsConfigPhaseTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the phase table entry." + ::= { atsConfigPhaseEntry 1 } + +atsConfigPhase OBJECT-TYPE + SYNTAX INTEGER { + phase1 (1), + phase2 (2), + phase3 (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The phase number of an ATS" + ::= { atsConfigPhaseEntry 2 } + +atsConfigPhaseLowLoadThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the current drawn is nearing + a low consumption condition. It is represented in Amps. + A warning will be issued when the load is less than the + threshold value. + + A threshold value of 0 Amps disables this warning. + + Maximum value must be less than the value returned + by the atsConfigPhaseNearOverLoadThreshold OID." + ::= { atsConfigPhaseEntry 3 } + +atsConfigPhaseNearOverLoadThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the current drawn is nearing + an overload condition. It is represented in Amps. + A warning will be issued when the load is greater than + or equal to the threshold value. + + Minimum value must be greater than the value returned by + the atsConfigPhaseLowLoadThreshold OID. + + Maximum value must be less than or equal to the value + returned by the atsConfigPhaseOverLoadThreshold OID." + ::= { atsConfigPhaseEntry 4 } + +atsConfigPhaseOverLoadThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold that indicates the current drawn has entered + an overload condition. It is represented in Amps. + A warning will be issued when the load is greater than or + equal to the threshold value. + + Minimum value must be greater than or equal to the value + returned by the atsConfigPhaseNearOverLoadThreshold OID. + + Maximum value must be less than or equal to the value + returned by atsIdentDeviceRating OID." + ::= { atsConfigPhaseEntry 5 } + + +-- the atsStatus group + + atsStatusCommStatus OBJECT-TYPE + SYNTAX INTEGER { + atsNeverDiscovered(1), + atsCommEstablished(2), + atsCommLost(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the current communication status + of the Automatic Transfer Switch. " + ::= { atsStatusDeviceStatus 1 } + + + atsStatusSelectedSource OBJECT-TYPE + SYNTAX INTEGER { + sourceA(1), + sourceB(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the current source of power. " + ::= { atsStatusDeviceStatus 2 } + + + atsStatusRedundancyState OBJECT-TYPE + SYNTAX INTEGER { + atsRedundancyLost(1), + atsFullyRedundant(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the current redundancy state of the ATS. + atsRedundancyLost(1) indicates that the ATS is unable to + switch over to the alternate power source if the current source fails. + atsFullyRedundant(2) indicates that the ATS will switch over to + the alternate power source if the current source fails." + ::= { atsStatusDeviceStatus 3 } + + + atsStatusOverCurrentState OBJECT-TYPE + SYNTAX INTEGER { + atsOverCurrent(1), + atsCurrentOK(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the output current state of the ATS. + atsOverCurrent(1) indicates that the ATS has exceeded the output + current threshold and will not allow a switch over to the alternate power + source if the current source fails. + atsCurrentOK(2) indicates that the output current is below the + output current threshold. + This OID returns the value of the OID atsOutputPhaseState for the 1U ATS and + OID atsOutputBankState for the 2U ATS." + ::= { atsStatusDeviceStatus 4 } + + + atsStatus5VPowerSupply OBJECT-TYPE + SYNTAX INTEGER { + atsPowerSupplyFailure(1), + atsPowerSupplyOK(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the present state of the ATS 5V power supply. + atsPowerSupplyFailure(1) indicates the 5V power supply has failed + and that the ATS serial port Configuration Menu is not accessible . + atsPowerSupplyOK(2) indicates that the ATS 5V power supply + is operating within tolerance." + ::= { atsStatusDeviceStatus 5 } + + + atsStatus24VPowerSupply OBJECT-TYPE + SYNTAX INTEGER { + atsPowerSupplyFailure(1), + atsPowerSupplyOK(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the present state of the ATS 24V power supply for Source A. + atsPowerSupplyFailure(1) indicates the 24V power supply has failed + and the ATS is unable to switch over to the alternate power source if + the current source fails. + atsPowerSupplyOK(2) indicates that the ATS 24V power supply + is operating within tolerance." + ::= { atsStatusDeviceStatus 6 } + + + atsStatus24VSourceBPowerSupply OBJECT-TYPE + SYNTAX INTEGER { + atsPowerSupplyFailure(1), + atsPowerSupplyOK(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the present state of the ATS 24V power supply for Source B. + atsPowerSupplyFailure(1) indicates the 24V power supply has failed + and the ATS is unable to switch over to the alternate power source if + the current source fails. + atsPowerSupplyOK(2) indicates that the ATS 24V power supply + is operating within tolerance." + ::= { atsStatusDeviceStatus 7 } + + + atsStatusPlus12VPowerSupply OBJECT-TYPE + SYNTAX INTEGER { + atsPowerSupplyFailure(1), + atsPowerSupplyOK(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the present state of the ATS 12V power supply. + atsPowerSupplyFailure(1) indicates the 12V power supply has failed + and the ATS is unable to monitor the current sensors. + atsPowerSupplyOK(2) indicates that the ATS 12V power supply + is operating within tolerance." + ::= { atsStatusDeviceStatus 8 } + + + atsStatusMinus12VPowerSupply OBJECT-TYPE + SYNTAX INTEGER { + atsPowerSupplyFailure(1), + atsPowerSupplyOK(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the present state of the ATS -12V power supply. + atsPowerSupplyFailure(1) indicates the -12V power supply has failed + and the ATS is unable to monitor the current sensors. + atsPowerSupplyOK(2) indicates that the ATS -12V power supply + is operating within tolerance." + ::= { atsStatusDeviceStatus 9 } + + + atsStatusSwitchStatus OBJECT-TYPE + SYNTAX INTEGER { + fail(1), + ok(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the status of the ATS." + ::= { atsStatusDeviceStatus 10 } + + + atsStatusFrontPanel OBJECT-TYPE + SYNTAX INTEGER { + locked(1), + unlocked(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the present state of the ATS front panel. + locked(1): Front panel button cannot be used to change the sources. + unlocked(2): Front panel button can be used to change the sources. " + + ::= { atsStatusDeviceStatus 11 } + + + atsStatusSourceAStatus OBJECT-TYPE + SYNTAX INTEGER { + fail(1), + ok(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the status of the Source A." + ::= { atsStatusDeviceStatus 12 } + + + atsStatusSourceBStatus OBJECT-TYPE + SYNTAX INTEGER { + fail(1), + ok(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the status of the Source B." + ::= { atsStatusDeviceStatus 13 } + + + atsStatusPhaseSyncStatus OBJECT-TYPE + SYNTAX INTEGER { + inSync(1), + outOfSync(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the status of the phase synch." + ::= { atsStatusDeviceStatus 14 } + + + atsStatusVoltageOutStatus OBJECT-TYPE + SYNTAX INTEGER { + fail(1), + ok(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the output voltage status." + ::= { atsStatusDeviceStatus 15 } + + + atsStatusHardwareStatus OBJECT-TYPE + SYNTAX INTEGER { + fail(1), + ok(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable returns the status of display board hardware." + ::= { atsStatusDeviceStatus 16 } + + + atsStatusResetMaxMinValues OBJECT-TYPE + SYNTAX INTEGER { + none(1), + reset(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Resets the maximum and minimum ATS values: + atsInputMaxVoltage, atsInputMinVoltage, + atsInputMaxCurrent, atsInputMinCurrent, + atsInputMaxPower, atsInputMinPower, + atsOutputMaxCurrent, atsOutputMinCurrent, + atsOutputMaxLoad, atsOutputMinLoad, + atsOutputMaxPercentLoad, atsOutputMinPercentLoad, + atsOutputMaxPower, atsOutputMinPower, + atsOutputMaxPercentPower, atsOutputMinPercentPower. + These variables represent the maximum and minimum ATS values + since the last time they were read or reset by this OID. + Values unsupported by this ATS will return (-1)." + ::= { atsStatusResetValues 1 } + +-- +-- Input Group +-- +-- Number of Inputs + atsNumInputs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of input feeds to this device. + This variable indicates the number of rows in the + input table." + ::= { atsStatusInput 1 } + +-- Input Table + + atsInputTable OBJECT-TYPE + SYNTAX SEQUENCE OF AtsInputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of input table entries. The number of entries + is given by the value of atsNumInputs." + ::= { atsStatusInput 2 } + + atsInputEntry OBJECT-TYPE + SYNTAX AtsInputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular input." + INDEX { atsInputTableIndex } + ::= { atsInputTable 1 } + + AtsInputEntry ::= SEQUENCE { + atsInputTableIndex INTEGER, + atsNumInputPhases INTEGER, + atsInputVoltageOrientation INTEGER, + atsInputFrequency INTEGER, + atsInputType INTEGER, + atsInputName DisplayString + } + + atsInputTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input identifier." + ::= { atsInputEntry 1 } + + atsNumInputPhases OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of input phases utilized in this + device. The sum of all the atsNumInputPhases + variable indicates the number of rows in the + input phase table." + ::= { atsInputEntry 2 } + + atsInputVoltageOrientation OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + singlePhase(2), + splitPhase(3), + threePhasePhaseToNeutral(4), + threePhasePhaseToPhase(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input voltage orientation: + 1: unknown for this Source + 2: singlePhase - phase 1 voltage is between Phase 1 + and Neutral. + 3: splitPhase - phase 1 voltage is between Phase 1 and + Neutral; phase 2 voltage is between Phase 2 and Neutral; + phase 3 voltage is between Phase 1 and Phase 2. + 4: threePhasePhaseToNeutral - phase 1 voltage is between + Phase 1 and Neutral; phase 2 voltage is between Phase 2 + and Neutral; phase 3 voltage is between Phase 3 and + Neutral. + 5: threePhasePhaseToPhase - phase 1 voltage is between + Phase 1 and Phase 2; phase 2 voltage is between Phase 2 + and Phase 3; phase 3 voltage is between Phase 3 and + Phase 1." + ::= { atsInputEntry 3 } + + atsInputFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input frequency in Hertz, or -1 if it's unsupported + by this Source." + ::= { atsInputEntry 4 } + + atsInputType OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + main(2), + bypass(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input type." + ::= { atsInputEntry 5 } + + atsInputName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A name given to a particular input." + ::= { atsInputEntry 6 } + +-- Input Phase Table + + atsInputPhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF AtsInputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of input table entries. The number of entries + is given by the sum of the atsNumInputPhases." + ::= { atsStatusInput 3 } + + atsInputPhaseEntry OBJECT-TYPE + SYNTAX AtsInputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular input phase." + INDEX { atsInputPhaseTableIndex, atsInputPhaseIndex } + ::= { atsInputPhaseTable 1 } + + AtsInputPhaseEntry ::= SEQUENCE { + atsInputPhaseTableIndex INTEGER, + atsInputPhaseIndex INTEGER, + atsInputVoltage INTEGER, + atsInputMaxVoltage INTEGER, + atsInputMinVoltage INTEGER, + atsInputCurrent INTEGER, + atsInputMaxCurrent INTEGER, + atsInputMinCurrent INTEGER, + atsInputPower INTEGER, + atsInputMaxPower INTEGER, + atsInputMinPower INTEGER + } + + atsInputPhaseTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input identifier." + ::= { atsInputPhaseEntry 1 } + + atsInputPhaseIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input phase identifier." + ::= { atsInputPhaseEntry 2 } + + atsInputVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input voltage in VAC, or -1 if it's unsupported + by this Source." + ::= { atsInputPhaseEntry 3 } + + atsInputMaxVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum input voltage in VAC measured + since the last time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsInputPhaseEntry 4 } + + atsInputMinVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum input voltage in VAC measured + since the last time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsInputPhaseEntry 5 } + + atsInputCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input current in amperes, or -1 if it's + unsupported by this Source." + ::= { atsInputPhaseEntry 6 } + + atsInputMaxCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum input current in amperes measured + since the last time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsInputPhaseEntry 7 } + + atsInputMinCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum input current in amperes measured + since the last time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsInputPhaseEntry 8 } + + atsInputPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input power in Watts, or -1 if it's unsupported + by this Source." + ::= { atsInputPhaseEntry 9 } + + atsInputMaxPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum input power in Watts measured + since the last time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsInputPhaseEntry 10 } + + atsInputMinPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum input power in Watts measured + since the last time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsInputPhaseEntry 11 } + + -- + -- The Output group. + -- + + -- Number of Outputs + + atsNumOutputs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of output feeds to this device. + This variable indicates the number of rows in the + output table." + ::= { atsStatusOutput 1 } + + -- Output Table + + atsOutputTable OBJECT-TYPE + SYNTAX SEQUENCE OF AtsOutputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of output table entries. The number of entries + is given by the value of atsOutputNumPhases." + ::= { atsStatusOutput 2 } + + atsOutputEntry OBJECT-TYPE + SYNTAX AtsOutputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular output." + INDEX { atsOutputTableIndex } + ::= { atsOutputTable 1 } + + AtsOutputEntry ::= SEQUENCE { + atsOutputTableIndex INTEGER, + atsNumOutputPhases INTEGER, + atsOutputVoltageOrientation INTEGER, + atsOutputFrequency INTEGER + } + + atsOutputTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output identifier." + ::= { atsOutputEntry 1 } + + atsNumOutputPhases OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of output phases utilized in this + device. The sum of all the atsNumOutputPhases + variable indicates the number of rows in the + output phase table." + ::= { atsOutputEntry 2 } + + atsOutputVoltageOrientation OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + singlePhase(2), + splitPhase(3), + threePhasePhaseToNeutral(4), + threePhasePhaseToPhase(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output voltage orientation: + 1: unknown for this ATS + 2: singlePhase - phase 1 voltage is between Phase 1 + and Neutral. + 3: splitPhase - phase 1 voltage is between Phase 1 and + Neutral; phase 2 voltage is between Phase 2 and Neutral; + phase 3 voltage is between Phase 1 and Phase 2. + 4: threePhasePhaseToNeutral - phase 1 voltage is between + Phase 1 and Neutral; phase 2 voltage is between Phase 2 + and Neutral; phase 3 voltage is between Phase 3 and + Neutral. + 5: threePhasePhaseToPhase - phase 1 voltage is between + Phase 1 and Phase 2; phase 2 voltage is between Phase 2 + and Phase 3; phase 3 voltage is between Phase 3 and + Phase 1." + ::= { atsOutputEntry 3 } + + atsOutputFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output frequency in Hertz, or -1 if it's + unsupported by this ATS." + ::= { atsOutputEntry 4 } + + -- Output Phase Table + + atsOutputPhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF AtsOutputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of output table entries. The number of + entries is given by the sum of the atsNumOutputPhases." + ::= { atsStatusOutput 3 } + + atsOutputPhaseEntry OBJECT-TYPE + SYNTAX AtsOutputPhaseEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information applicable to a + particular output phase." + INDEX { atsOutputPhaseTableIndex, atsOutputPhaseIndex } + ::= { atsOutputPhaseTable 1 } + + AtsOutputPhaseEntry ::= SEQUENCE { + atsOutputPhaseTableIndex INTEGER, + atsOutputPhaseIndex INTEGER, + atsOutputVoltage INTEGER, + atsOutputCurrent INTEGER, + atsOutputMaxCurrent INTEGER, + atsOutputMinCurrent INTEGER, + atsOutputLoad INTEGER, + atsOutputMaxLoad INTEGER, + atsOutputMinLoad INTEGER, + atsOutputPercentLoad INTEGER, + atsOutputMaxPercentLoad INTEGER, + atsOutputMinPercentLoad INTEGER, + atsOutputPower INTEGER, + atsOutputMaxPower INTEGER, + atsOutputMinPower INTEGER, + atsOutputPercentPower INTEGER, + atsOutputMaxPercentPower INTEGER, + atsOutputMinPercentPower INTEGER, + atsOutputPhaseState INTEGER + } + + atsOutputPhaseTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output identifier." + ::= { atsOutputPhaseEntry 1 } + + atsOutputPhaseIndex OBJECT-TYPE + SYNTAX INTEGER{ + phase1(1), + phase2(2), + phase3(3), + neutral(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of each output phase utilized in + this device and one for neutral. " + ::= { atsOutputPhaseEntry 2 } + + atsOutputVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output voltage in VAC, or -1 if it's unsupported + by this ATS." + ::= { atsOutputPhaseEntry 3 } + + atsOutputCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output current in 0.1 amperes drawn + by the load on the ATS, or -1 if it's unsupported + by this ATS." + ::= { atsOutputPhaseEntry 4 } + + atsOutputMaxCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum output current in 0.1 amperes measured + since the last time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputPhaseEntry 5 } + + atsOutputMinCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum output current in 0.1 amperes measured + since the last time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputPhaseEntry 6 } + + atsOutputLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output load in VA, or -1 if it's unsupported + by this ATS." + ::= { atsOutputPhaseEntry 7 } + + atsOutputMaxLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum output load in VA measured + since the last time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputPhaseEntry 8 } + + atsOutputMinLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum output load in VA measured + since the last time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputPhaseEntry 9 } + + atsOutputPercentLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The percentage of the ATS load capacity in VA at + redundancy @ (n + x) presently being used on this + output phase, or -1 if it's unsupported by this ATS." + ::= { atsOutputPhaseEntry 10 } + + atsOutputMaxPercentLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum percentage of the ATS load capacity in + VA measured at redundancy @ (n + x) presently + being used on this output phase since the last time + this variable was read or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputPhaseEntry 11 } + + atsOutputMinPercentLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum percentage of the ATS load capacity in + VA measured at redundancy @ (n + x) presently + being used on this output phase since the last time + this variable was read or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputPhaseEntry 12 } + + atsOutputPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output power in Watts, or -1 if it's + unsupported by this ATS." + ::= { atsOutputPhaseEntry 13 } + + atsOutputMaxPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum output power in Watts measured + since the last time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputPhaseEntry 14 } + + atsOutputMinPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum output power in Watts measured + since the last time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputPhaseEntry 15 } + + atsOutputPercentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The percentage of the ATSpower capacity in Watts at + redundancy @ (n + x) presently being used on this + output phase, or -1 if it's unsupported by this ATS." + ::= { atsOutputPhaseEntry 16 } + + atsOutputMaxPercentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum percentage of the ATSpower capacity + in Watts measured at redundancy @ (n + x) presently + being used on this output phase since the last time + this variable was read or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputPhaseEntry 17 } + + atsOutputMinPercentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum percentage of the ATSpower capacity + in Watts measured at redundancy @ (n + x) presently + being used on this output phase since the last time + this variable was read or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputPhaseEntry 18 } + + + atsOutputPhaseState OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + lowload (2), + nearoverload (3), + overload (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the phase load state. + + normal(1) indicates that the bank is operating properly + within the atsConfigPhaseLowLoadThreshold and + atsConfigPhaseNearOverLoadThreshold OID values. + + lowload(2) indicates that the bank load has dropped below + the atsConfigPhaseLowLoadThreshold OID value. An SNMP trap + will occur when this state is entered or cleared. + + nearoverload(3) indicates that the bank load is greater than + or equal to the atsConfigPhaseNearOverLoadThreshold OID value. + An SNMP trap will occur when this state is entered or cleared. + + overload(4) indicates that the bank load is greater than or + equal to the atsConfigPhaseOverLoadThreshold OID value. + An SNMP trap will occur when this state is entered or cleared." + ::= { atsOutputPhaseEntry 19 } + + + atsOutputBankTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The size of the bank table." + ::= { atsStatusOutput 4 } + + + atsOutputBankTable OBJECT-TYPE + SYNTAX SEQUENCE OF ATSOutputBankEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting table entries." + ::= { atsStatusOutput 5 } + + atsOutputBankEntry OBJECT-TYPE + SYNTAX ATSOutputBankEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This gives access to bank table entries" + INDEX { atsOutputBankTableIndex } + ::= { atsOutputBankTable 1 } + + ATSOutputBankEntry ::= + SEQUENCE { + atsOutputBankTableIndex INTEGER, + atsOutputPhase INTEGER, + atsOutputBank INTEGER, + atsOutputBankCurrent Gauge, + atsOutputBankState INTEGER, + atsOutputBankOutputVoltage INTEGER, + atsOutputBankMaxCurrent INTEGER, + atsOutputBankMinCurrent INTEGER, + atsOutputBankLoad INTEGER, + atsOutputBankMaxLoad INTEGER, + atsOutputBankMinLoad INTEGER, + atsOutputBankPercentLoad INTEGER, + atsOutputBankMaxPercentLoad INTEGER, + atsOutputBankMinPercentLoad INTEGER, + atsOutputBankPower INTEGER, + atsOutputBankMaxPower INTEGER, + atsOutputBankMinPower INTEGER, + atsOutputBankPercentPower INTEGER, + atsOutputBankMaxPercentPower INTEGER, + atsOutputBankMinPercentPower INTEGER + } + + atsOutputBankTableIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the bank table entry." + ::= { atsOutputBankEntry 1 } + + atsOutputPhase OBJECT-TYPE + SYNTAX INTEGER { + phase1 (1), + phase2 (2), + phase3 (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The phase number of an ATS" + ::= { atsOutputBankEntry 2 } + + atsOutputBank OBJECT-TYPE + SYNTAX INTEGER { + total (1), + bank1 (2), + bank2 (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The bank number of an ATS" + ::= { atsOutputBankEntry 3 } + + atsOutputBankCurrent OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the bank current measured + in tenths of Amps." + ::= { atsOutputBankEntry 4 } + + atsOutputBankState OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + lowload (2), + nearoverload (3), + overload (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return the bank load state. + + normal(1) indicates that the bank is + operating properly within the atsConfigBankLowLoadThreshold + and atsConfigBankNearOverLoadThreshold OID values. + + lowload(2) indicates that the bank load has dropped below the + atsConfigBankLowLoadThreshold OID value. An SNMP trap will + occur when this state is entered or cleared. + + nearoverload(3) indicates that the bank load is greater than + or equal to the atsConfigBankNearOverLoadThreshold OID value. + An SNMP trap will occur when this state is entered or cleared. + + overload(4) indicates that the bank load is greater than or + equal to the atsConfigBankOverLoadThreshold OID value. + An SNMP trap will occur when this state is entered or cleared." + ::= { atsOutputBankEntry 5 } + + atsOutputBankOutputVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output voltage in VAC, or -1 if it's unsupported + by this ATS." + ::= { atsOutputBankEntry 6 } + + + atsOutputBankMaxCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum output current, on the bank represented by + OID atsOutputBank, in 0.1 amperes measured since the + last time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputBankEntry 7 } + + atsOutputBankMinCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum output current, on the bank represented by + OID atsOutputBank, in 0.1 amperes measured since the + last time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputBankEntry 8 } + + atsOutputBankLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output load, on the bank represented by + OID atsOutputBank, in VA, or -1 if it's + unsupported by this ATS." + ::= { atsOutputBankEntry 9 } + + atsOutputBankMaxLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum output load, on the bank represented by + OID atsOutputBank, in VA measured since the last + time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputBankEntry 10 } + + atsOutputBankMinLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum output load, on the bank represented by + OID atsOutputBank, in VA measured since the last + time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputBankEntry 11 } + + atsOutputBankPercentLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The percentage of the ATS load capacity in VA at + redundancy @ (n + x) presently being used on this + bank, represented by OID atsOutputBank. + Returns (-1) if unsupported." + ::= { atsOutputBankEntry 12 } + + atsOutputBankMaxPercentLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum percentage of the ATS load capacity in + VA measured at redundancy @ (n + x) presently + being used on this bank, represented by OID atsOutputBank, + since the last time this variable was read or + reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputBankEntry 13 } + + atsOutputBankMinPercentLoad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum percentage of the ATS load capacity in + VA measured at redundancy @ (n + x) presently + being used on this bank, represented by OID + atsOutputBank, since the last time this variable was + read or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputBankEntry 14 } + + atsOutputBankPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output power in Watts on the bank represented by + OID atsOutputBank or -1 if it's unsupported by this ATS." + ::= { atsOutputBankEntry 15 } + + atsOutputBankMaxPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum output power in Watts measured on the bank + represented by OID atsOutputBank since the last + time this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputBankEntry 16 } + + atsOutputBankMinPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum output power in Watts measured on the bank + represented by OID atsOutputBank since the last time + this variable was read + or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputBankEntry 17 } + + atsOutputBankPercentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The percentage of the ATSpower capacity in Watts at + redundancy @ (n + x) presently being used on this + bank, represented by OID atsOutputBank, or + -1 if it's unsupported by this ATS." + ::= { atsOutputBankEntry 18 } + + atsOutputBankMaxPercentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum percentage of the ATSpower capacity + in Watts measured at redundancy @ (n + x) presently + being used on this bank, represented by OID + atsOutputBank, since the last time this variable + was read or reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputBankEntry 19 } + + atsOutputBankMinPercentPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum percentage of the ATSpower capacity + in Watts measured at redundancy @ (n + x) presently + being used on this bank, represented by OID atsOutputBank + since the last time this variable was read or + reset (atsStatusResetMaxMinValues). + Returns (-1) if unsupported." + ::= { atsOutputBankEntry 20 } + + +-- the dcmim2IdentSystem group + +dcmim2IdentSysFWVersion OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Integer representation of the power plant Master Controller firmware revision." + ::= { dcmim2IdentSystem 1 } + + +-- the dcmim2ControlSystem group + +dcmim2ControlRunFunctBatteryTest OBJECT-TYPE + SYNTAX INTEGER { + battTestOff (1), + battTestOn (2) +} + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this OID will return the battery functional test state. If + the test is off, the battTestOff (1) value will be returned. + If the test is on, the battTestOn (2) value will be + returned. + + Setting this OID to battTestOff (1) will turn the battery functional test off. + Setting this OID to battTestOn (2) will turn the battery functional test on." + + ::= { dcmim2ControlSystem 1 } + +dcmim2ControlRunCapacityBatteryTest OBJECT-TYPE + SYNTAX INTEGER { + battTestOff (1), + battTestOn (2) +} + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this OID will return the battery capacity test state. If + the test is off, the battTestOff (1) value will be returned. + If the test is on, the battTestOn (2) value will be + returned. + + Setting this OID to battTestOff (1) will turn the battery capacity test off. + Setting this OID to battTestOn (2) will turn the battery capacity test on." + + ::= { dcmim2ControlSystem 2 } + + +-- the dcmim2ConfigSystem group + +dcmim2ConfigSysHighTempTrip OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Trip level (threshold) at which System High Temp alarm condition is created. + Range 28 to 100 (degC). + + Values are represented in thousandths of a degree. + Units are displayed in the scale shown in + the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)." + + + ::= { dcmim2ConfigSystem 1 } + +dcmim2ConfigSysHighTempReset OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Level at which System High Temp alarm condition is reset (cleared). + Range 25 to (upper temp - 3) (degC). + + Values are represented in thousandths of a degree. + Units are displayed in the scale shown in + the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)." + + ::= { dcmim2ConfigSystem 2 } + +dcmim2ConfigSysLowTempTrip OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Trip level (threshold) at which System Low Temp alarm condition is created. + Range -100 to 10 (degC). + Values are represented in thousandths of a degree. + Units are displayed in the scale shown in + the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)." + + ::= { dcmim2ConfigSystem 3 } + +dcmim2ConfigSysLowTempReset OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Level at which System Low Temp alarm condition is reset (cleared). + Range (lower temp + 3) to 13 (degC). + Values are represented in thousandths of a degree. + Units are displayed in the scale shown in + the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)." + + ::= { dcmim2ConfigSystem 4 } + +-- the dcmim2ConfigBattery group + +dcmim2ConfigBattFloatVolt OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Battery Float Voltage defined at 25 degrees Celsius. + + Values are represented in thousandths of Volts (mV)." + + ::= { dcmim2ConfigBattery 1 } + +dcmim2ConfigBattMaxRecharge OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Battery Maximum Recharge Rate. This is the maximum current used + during battery charging. + + Values are represented in thousandths of Amps (mA)." + + ::= { dcmim2ConfigBattery 2 } + +dcmim2ConfigBattMfgCapacity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Battery capacity (Amp-Hour Size) as specified by the battery manufacturer. + + Values are represented in thousandths of Amp hours (mAHr)." + + ::= { dcmim2ConfigBattery 3 } + +dcmim2ConfigBattType OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Type of battery in the powerplant + + Valid values range from 0 to 254." + + ::= { dcmim2ConfigBattery 4 } + +dcmim2ConfigBattFunctTestDuration OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Duration of the battery functional test. + + Values are represented in thousandths of seconds (mSecs)." + + ::= { dcmim2ConfigBattery 5 } + +dcmim2ConfigBattFunctTestThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold the battery voltage of the system must remain above + in order to pass the battery functional test. + + Values are represented in thousandths of Volts (mV)." + + ::= { dcmim2ConfigBattery 6 } + +dcmim2ConfigBattCapacityTestPercent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold for good battery capacity test results. + + Values range from 0 to 100 percent." + + ::= { dcmim2ConfigBattery 7 } + +dcmim2ConfigBattCapacityTestEndThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Safeguard voltage at which battery capacity test will end + if there is a battery problem. + + Values are represented in thousandths of Volts (mV)." + + ::= { dcmim2ConfigBattery 8 } + +dcmim2ConfigBattCapacityTestCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Constant current value used during battery capacity testing. + + Values are represented in thousandths of Amps (mA)." + + ::= { dcmim2ConfigBattery 9 } + + +-- the dcmim2ConfigLVD group + +dcmim2ConfigLVDTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant LVDs controllable + by this IP address." + ::= { dcmim2ConfigLVD 1 } + +dcmim2ConfigLVDTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dcmim2ConfigLVDEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for accessing settings of the LVDs. The number of + entries is contained in the dcmim2ConfigLVDTableSize OID." + ::= { dcmim2ConfigLVD 2 } + +dcmim2ConfigLVDEntry OBJECT-TYPE + SYNTAX Dcmim2ConfigLVDEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The LVD to configure." + INDEX { dcmim2ConfigLVDIndex } + ::= { dcmim2ConfigLVDTable 1 } + +Dcmim2ConfigLVDEntry ::= + SEQUENCE { + dcmim2ConfigLVDIndex INTEGER, + dcmim2ConfigLVDTrip INTEGER, + dcmim2ConfigLVDReset INTEGER, + dcmim2ConfigLVDState INTEGER + } + +dcmim2ConfigLVDIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant LVD." + ::= { dcmim2ConfigLVDEntry 1 } + +dcmim2ConfigLVDTrip OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "LVD Trip threshold. System bus voltage at which LVD will trip (open) + during a battery backup operation. + + Values are represented in thousandths of Volts (mV)." + ::= { dcmim2ConfigLVDEntry 2 } + +dcmim2ConfigLVDReset OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "LVD Reset threshold. System bus voltage at which LVD will reset (close) + after AC power has been restored. + + Values are represented in thousandths of Volts (mV)." + ::= { dcmim2ConfigLVDEntry 3 } + +dcmim2ConfigLVDState OBJECT-TYPE + SYNTAX INTEGER { + statusClosed (1), + statusOpened (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusClosed (1) if the LVD is closed. + statusOpened (2) will be returned if the LVD is opened." + ::= { dcmim2ConfigLVDEntry 4 } + + +-- the dcmim2StatusSystem group + +dcmim2StatusSysRectCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "System (Total Rectifier) current in thousandths of Amps (mA)." + ::= { dcmim2StatusSystem 1 } + +dcmim2StatusSysLoadCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Load current in thousandths of Amps (mA)." + ::= { dcmim2StatusSystem 2 } + +dcmim2StatusSysBusVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "System bus voltage in thousandths of Volts (mV)." + ::= { dcmim2StatusSystem 3 } + +dcmim2StatusSysAmbientTemp OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "System temperature based on sensor on Master Controller PCB. + + Values are represented in thousandths of a degree. + Units are displayed in the scale shown in + the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)." + ::= { dcmim2StatusSystem 4 } + +dcmim2StatusSysUpTime OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Length of time since the DC Powerplant controller has been powered up." + ::= { dcmim2StatusSystem 5 } + +dcmim2StatusSysTempUnits OBJECT-TYPE + SYNTAX INTEGER { + celsius(1), + fahrenheit(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature scale used to display the temperature + in the DC system, Celsius(1) or Fahrenheit(2). + This setting is based on the system preferences + configuration in the agent." + ::= { dcmim2StatusSystem 6 } + + +-- the dcmim2StatusRectifier group + +dcmim2StatusRectTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant rectifiers viewable + by this IP address." + ::= { dcmim2StatusRectifier 1 } + +dcmim2StatusRectTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dcmim2StatusRectEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for accessing settings of the rectifiers. The number of + entries is contained in the dcmim2StatusRectTableSize OID." + ::= { dcmim2StatusRectifier 2 } + +dcmim2StatusRectEntry OBJECT-TYPE + SYNTAX Dcmim2StatusRectEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The rectifier to gather status from." + INDEX { dcmim2StatusRectIndex } + ::= { dcmim2StatusRectTable 1 } + +Dcmim2StatusRectEntry ::= + SEQUENCE { + dcmim2StatusRectIndex INTEGER, + dcmim2StatusRectDevType INTEGER, + dcmim2StatusRectID INTEGER, + dcmim2StatusRectPhyAddr INTEGER, + dcmim2StatusRectFail INTEGER, + dcmim2StatusRectCurrent INTEGER + } + +dcmim2StatusRectIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant rectifier." + ::= { dcmim2StatusRectEntry 1 } + +dcmim2StatusRectDevType OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the rectifier device type." + ::= { dcmim2StatusRectEntry 2 } + +dcmim2StatusRectID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the rectifier ID. This enumerates the number of the rectifier within + a group of rectifiers." + ::= { dcmim2StatusRectEntry 3 } + +dcmim2StatusRectPhyAddr OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the rectifier physical address (the address on the bus)." + ::= { dcmim2StatusRectEntry 4 } + +dcmim2StatusRectFail OBJECT-TYPE + SYNTAX INTEGER { + statusTrue (1), + statusFalse (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusTrue (1) if the rectifier has failed. + statusFalse (2) will be returned if the rectifier has not failed." + ::= { dcmim2StatusRectEntry 5 } + +dcmim2StatusRectCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID shows the individual rectifier current in thousandths of Amps (mA)." + ::= { dcmim2StatusRectEntry 6 } + + +-- the dcmim2StatusBattery group + +dcmim2StatusBattFloatVolt OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Battery Float Voltage represented in thousandths of Volts (mV)." + ::= { dcmim2StatusBattery 1 } + +dcmim2StatusBattCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Battery Current: This OID shows the battery current in thousandths of Amps (mA)." + ::= { dcmim2StatusBattery 2 } + +dcmim2StatusBattTemp OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Battery Temperature: + + Values are represented in thousandths of a degree. + Units are displayed in the scale shown in + the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)." + ::= { dcmim2StatusBattery 3 } + +dcmim2StatusBattMfgCapacity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Battery capacity (Amp-Hour Size) as specified by the battery manufacturer. + Values are represented in thousandths of Amp hours (mAHr)." + ::= { dcmim2StatusBattery 4 } + +dcmim2StatusBattTestCapacity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Battery capacity (Amp-Hour Size) as determined by the battery capacity test. + Values are represented in thousandths of Amp hours (mAHr)." + ::= { dcmim2StatusBattery 5 } + +dcmim2StatusBattFunctTestResult OBJECT-TYPE + SYNTAX INTEGER{ + functTestNotPerformed (1), + functTestInProcess (2), + functTestInterrupted (3), + functTestPass (4), + functTestFail (5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Results of the last battery functional test that was run." + ::= { dcmim2StatusBattery 6 } + +dcmim2StatusBattCapacityTestResult OBJECT-TYPE + SYNTAX INTEGER{ + capacityTestNotPerformed (1), + capacityTestInProcess (2), + capacityTestInterrupted (3), + capacityTestPass (4), + capacityTestFail (5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Results of the last battery capacity test that was run." + ::= { dcmim2StatusBattery 7 } + + +-- the dcmim2StatusLVD group + +dcmim2StatusLVDTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant LVDs accessible + by this IP address." + ::= { dcmim2StatusLVD 1 } + +dcmim2StatusLVDTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dcmim2StatusLVDEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for accessing the LVDs. The number of + entries is contained in the dcmim2StatusLVDTableSize OID." + ::= { dcmim2StatusLVD 2 } + +dcmim2StatusLVDEntry OBJECT-TYPE + SYNTAX Dcmim2StatusLVDEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The LVD to access." + INDEX { dcmim2StatusLVDIndex } + ::= { dcmim2StatusLVDTable 1 } + +Dcmim2StatusLVDEntry ::= + SEQUENCE { + dcmim2StatusLVDIndex INTEGER, + dcmim2StatusLVDState INTEGER + } + +dcmim2StatusLVDIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the DC powerplant LVD." + ::= { dcmim2StatusLVDEntry 1 } + +dcmim2StatusLVDState OBJECT-TYPE + SYNTAX INTEGER { + statusClosed (1), + statusOpened (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this OID will return statusClosed (1) if the LVD is closed. + statusOpened (2) will be returned if the LVD is opened." + ::= { dcmim2StatusLVDEntry 2 } + + +-- the dcmim2StatusAlarms group + +dcmim2StatusAlarmsTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of DC powerplant alarms viewable + by this IP address." + ::= { dcmim2StatusAlarms 1 } + +dcmim2StatusAlarmsTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dcmim2StatusAlarmsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for accessing system alarms. The number of + entries is contained in the dcmim2StatusAlarmsTableSize OID." + ::= { dcmim2StatusAlarms 2 } + +dcmim2StatusAlarmsEntry OBJECT-TYPE + SYNTAX Dcmim2StatusAlarmsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The alarm to display." + INDEX { dcmim2StatusAlarmsIndex } + ::= { dcmim2StatusAlarmsTable 1 } + +Dcmim2StatusAlarmsEntry ::= + SEQUENCE { + dcmim2StatusAlarmsIndex INTEGER, + dcmim2StatusAlarmsText DisplayString + } + +dcmim2StatusAlarmsIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the system alarm." + ::= { dcmim2StatusAlarmsEntry 1 } + +dcmim2StatusAlarmsText OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The 16 character text describing the active alarm condition." + ::= { dcmim2StatusAlarmsEntry 2 } + +-- External Environmental Monitor + +emIdentFirmwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of the Environmental Monitor." + ::= { emIdent 1 } + +emConfigProbesNumProbes OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of temperature and humidity probes available." + ::= { emConfig 1 } + +emConfigProbesTable OBJECT-TYPE + SYNTAX SEQUENCE OF EmConfigProbesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of probes supported by the Environmental Monitor + and their configurations." + ::= { emConfig 2 } + +emConfigProbesEntry OBJECT-TYPE + SYNTAX EmConfigProbesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The Environmental Monitor probe configurations." + INDEX { emConfigProbeNumber } + ::= { emConfigProbesTable 1 } + +EmConfigProbesEntry ::= + SEQUENCE { + emConfigProbeNumber + INTEGER, + emConfigProbeName + DisplayString, + emConfigProbeHighTempThreshold + INTEGER, + emConfigProbeLowTempThreshold + INTEGER, + emConfigProbeTempUnits + INTEGER, + emConfigProbeHighHumidThreshold + INTEGER, + emConfigProbeLowHumidThreshold + INTEGER, + emConfigProbeHighTempEnable + INTEGER, + emConfigProbeLowTempEnable + INTEGER, + emConfigProbeHighHumidEnable + INTEGER, + emConfigProbeLowHumidEnable + INTEGER, + emConfigProbeMaxTempThreshold + INTEGER, + emConfigProbeMinTempThreshold + INTEGER, + emConfigProbeMaxHumidThreshold + INTEGER, + emConfigProbeMinHumidThreshold + INTEGER, + emConfigProbeMaxTempEnable + INTEGER, + emConfigProbeMinTempEnable + INTEGER, + emConfigProbeMaxHumidEnable + INTEGER, + emConfigProbeMinHumidEnable + INTEGER, + emConfigProbeTempHysteresis + INTEGER, + emConfigProbeHumidHysteresis + INTEGER, + emConfigProbeLocation + DisplayString + } + +emConfigProbeNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index into an Environmental Monitor probe entry." + ::= { emConfigProbesEntry 1 } + +emConfigProbeName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A descriptive name of the probe set by the user, + possibly denoting its location or purpose." + ::= { emConfigProbesEntry 2 } + +emConfigProbeHighTempThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The high temperature alarm threshold for the probe. + Units are displayed in the scale selected in + the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)." + ::= { emConfigProbesEntry 3 } + +emConfigProbeLowTempThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low temperature alarm threshold for the probe. + Units are displayed in the scale selected in + the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)." + ::= { emConfigProbesEntry 4 } + +emConfigProbeTempUnits OBJECT-TYPE + SYNTAX INTEGER { + celsius(1), + fahrenheit(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature scale used to display the temperature + thresholds of the probe, Celsius(1) or Fahrenheit(2). + This setting is based on the system preferences + configuration in the agent." + ::= { emConfigProbesEntry 5 } + +emConfigProbeHighHumidThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The high humidity alarm threshold for the probe in + percent relative humidity." + ::= { emConfigProbesEntry 6 } + +emConfigProbeLowHumidThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low humidity alarm threshold for the probe in + percent relative humidity." + ::= { emConfigProbesEntry 7 } + +emConfigProbeHighTempEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The high temperature alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { emConfigProbesEntry 8 } + +emConfigProbeLowTempEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low temperature alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { emConfigProbesEntry 9 } + +emConfigProbeHighHumidEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The high humidity alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { emConfigProbesEntry 10 } + +emConfigProbeLowHumidEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low humidity alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { emConfigProbesEntry 11 } + +emConfigProbeMaxTempThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum temperature alarm threshold for the probe. + Units are displayed in the scale selected in + the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)." + ::= { emConfigProbesEntry 12 } + +emConfigProbeMinTempThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The minimum temperature alarm threshold for the probe. + Units are displayed in the scale selected in + the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)." + ::= { emConfigProbesEntry 13 } + +emConfigProbeMaxHumidThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximun humidity alarm threshold for the probe in + percent relative humidity." + ::= { emConfigProbesEntry 14 } + +emConfigProbeMinHumidThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The minimum humidity alarm threshold for the probe in + percent relative humidity." + ::= { emConfigProbesEntry 15 } + +emConfigProbeMaxTempEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum temperature alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { emConfigProbesEntry 16 } + +emConfigProbeMinTempEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The minimum temperature alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { emConfigProbesEntry 17 } + +emConfigProbeMaxHumidEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum humidity alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { emConfigProbesEntry 18 } + +emConfigProbeMinHumidEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The minimum humidity alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { emConfigProbesEntry 19 } + +emConfigProbeTempHysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of degrees beyond the temperature thresholds + at which an active temperature alarm will be cleared. + This configuration setting applies to all temperature + thresholds. + Units are displayed in the scale selected in + the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)." + ::= { emConfigProbesEntry 20 } + +emConfigProbeHumidHysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of percent RH points beyond the humidity + thresholds at which an active humidity alarm will be + cleared. This configuration setting applies to all + humidity thresholds. + Units are displayed in the scale selected in + the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)." + ::= { emConfigProbesEntry 21 } + +emConfigProbeLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A string describing the location of the probe." + ::= { emConfigProbesEntry 22 } + +emConfigContactsNumContacts OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of contacts supported by the Environmental + Monitor." + ::= { emConfig 3 } + +emConfigContactsTable OBJECT-TYPE + SYNTAX SEQUENCE OF EmConfigContactsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of contacts supported by the Environmental Monitor + and their configurations." + ::= { emConfig 4 } + +emConfigContactsEntry OBJECT-TYPE + SYNTAX EmConfigContactsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The Environmental Monitor contact configurations." + INDEX { emConfigContactNumber } + ::= { emConfigContactsTable 1 } + +EmConfigContactsEntry ::= + SEQUENCE { + emConfigContactNumber + INTEGER, + emConfigContactName + DisplayString, + emConfigContactEnable + INTEGER, + emConfigContactSeverity + INTEGER, + emConfigContactNormalState + INTEGER, + emConfigContactLocation + DisplayString + } + +emConfigContactNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of an Environmental Monitor contact." + ::= { emConfigContactsEntry 1 } + +emConfigContactName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A descriptive name for an Environmental Monitor + contact set by the user, possibly denoting its + location or purpose." + ::= { emConfigContactsEntry 2 } + +emConfigContactEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "An Environmental Monitor contact alarm enable/disable. + No alarm will be generated if the contact is disabled(1). + An alarm will be generated if the contact is enabled(2) + and the contact has been faulted." + ::= { emConfigContactsEntry 3 } + +emConfigContactSeverity OBJECT-TYPE + SYNTAX INTEGER { + critical(1), + warning(2), + informational(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The severity of the alarm that will be triggered when + the input contact is activated. The alarms can be + critical(1), warning(2) or informational(3)." + ::= { emConfigContactsEntry 4 } + +emConfigContactNormalState OBJECT-TYPE + SYNTAX INTEGER { + open(1), + closed(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The contact state that will be considered normal, i.e. + will not trigger an alarm. The states are open(1) or + closed(2)." + ::= { emConfigContactsEntry 5 } + +emConfigContactLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A descriptive label for the contact denoting its + location or purpose." + ::= { emConfigContactsEntry 6 } + +emStatusCommStatus OBJECT-TYPE + SYNTAX INTEGER { + noComm(1), + comm(2), + commLost(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The communication status between the agent + and the Environmental Monitor. + + noComm(1), Communication has never been established. + comm(2), Communication has been established. + commLost(3), Communication was established, but was lost." + ::= { emStatus 1 } + +emStatusProbesNumProbes OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of available probes on the Environmental + Monitor." + ::= { emStatus 2 } + +emStatusProbesTable OBJECT-TYPE + SYNTAX SEQUENCE OF EmStatusProbesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of probes supported by the Environmental Monitor + and their status." + ::= { emStatus 3 } + +emStatusProbesEntry OBJECT-TYPE + SYNTAX EmStatusProbesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The status of the probe." + INDEX { emStatusProbeNumber } + ::= { emStatusProbesTable 1 } + +EmStatusProbesEntry ::= + SEQUENCE { + emStatusProbeNumber + INTEGER, + emStatusProbeName + DisplayString, + emStatusProbeStatus + INTEGER, + emStatusProbeCurrentTemp + INTEGER, + emStatusProbeTempUnits + INTEGER, + emStatusProbeCurrentHumid + INTEGER, + emStatusProbeHighTempViolation + INTEGER, + emStatusProbeLowTempViolation + INTEGER, + emStatusProbeHighHumidViolation + INTEGER, + emStatusProbeLowHumidViolation + INTEGER, + emStatusProbeMaxTempViolation + INTEGER, + emStatusProbeMinTempViolation + INTEGER, + emStatusProbeMaxHumidViolation + INTEGER, + emStatusProbeMinHumidViolation + INTEGER + } + +emStatusProbeNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the probe." + ::= { emStatusProbesEntry 1 } + +emStatusProbeName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A descriptive name for the probe set by the user, + possibly denoting its location or purpose." + ::= { emStatusProbesEntry 2 } + +emStatusProbeStatus OBJECT-TYPE + SYNTAX INTEGER { + disconnected(1), + connected(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The connected status of the probe, either + disconnected(1) or connected(2)." + ::= { emStatusProbesEntry 3 } + +emStatusProbeCurrentTemp OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current temperature reading from the probe displayed + in the units shown in the 'emStatusProbeTempUnits' OID + (Celsius or Fahrenheit)." + ::= { emStatusProbesEntry 4 } + +emStatusProbeTempUnits OBJECT-TYPE + SYNTAX INTEGER { + celsius(1), + fahrenheit(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature scale used to display the temperature + thresholds of the probe, Celsius(1) or Fahrenheit(2). + This setting is based on the system preferences + configuration in the agent." + ::= { emStatusProbesEntry 5 } + +emStatusProbeCurrentHumid OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current humidity reading from the probe in + percent relative humidity." + ::= { emStatusProbesEntry 6 } + +emStatusProbeHighTempViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + highTempViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The high temperature violation status of the probe + temperature reading. This OID will show a highTempViolation(2) + if the current temperature reading shown in the + 'emStatusProbeCurrentTemp' OID is greater than or equal to + the high temperature threshold value, the + 'emConfigProbeHighTempThreshold' OID, and the value of the + 'emConfigProbeHighTempEnable' OID is enabled. Otherwise it will show + noViolation(1). If the 'emConfigProbeHighTempEnable' OID is disabled, + this OID will show disabled(3)." + ::= { emStatusProbesEntry 7 } + +emStatusProbeLowTempViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + lowTempViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The high temperature violation status of the probe + temperature reading. This OID will show a lowTempViolation(2) + if the current temperature reading shown in the + 'emStatusProbeCurrentTemp' OID is less than or equal to + the low temperature threshold value, the + 'emConfigProbeLowTempThreshold' OID, and the value of the + 'emConfigProbeLowTempEnable' OID is enabled. Otherwise it will show + noViolation(1). If the 'emConfigProbeLowTempEnable' OID is disabled, + this OID will show disabled(3)." + ::= { emStatusProbesEntry 8 } + +emStatusProbeHighHumidViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + highHumidViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The high humidity violation status of the probe humidity + reading. This OID will show a highTempViolation(2) + if the current humidity reading shown in the + 'emStatusProbeCurrentHumid' OID is greater than or equal to + the high humidity threshold value, the + 'emConfigProbeHighHumidThreshold' OID, and the value of the + 'emConfigProbeHighHumidEnable' OID is enabled. Otherwise it will + show noViolation(1). If the 'emConfigProbeHighHumidEnable' OID is + disabled, this OID will show disabled(3)" + ::= { emStatusProbesEntry 9 } + +emStatusProbeLowHumidViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + lowHumidViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The low humidity violation status of the probe humidity + reading. This OID will show a lowTempViolation(2) + if the current humidity reading shown in the + 'emStatusProbeCurrentHumid' OID is less than or equal to + the low humidity threshold value, the + 'emConfigProbeLowHumidThreshold' OID, and the value of the + 'emConfigProbeLowHumidEnable' OID is enabled. Otherwise it will + show noViolation(1). If the 'emConfigProbeLowHumidEnable' OID is + disabled, this OID will show disabled(3)." + ::= { emStatusProbesEntry 10 } + +emStatusProbeMaxTempViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + maxTempViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The max temperature violation status of the probe + temperature reading. This OID will show a maxTempViolation(2) + if the current temperature reading shown in the + 'emStatusProbeCurrentTemp' OID is greater than or equal to + the maximun temperature threshold value, the + 'emConfigProbeMaxTempThreshold' OID, and the value of the + 'emConfigProbeMaxTempEnable' OID is enabled. Otherwise it will show + noViolation(1). If the 'emConfigProbeMaxTempEnable' OID is disabled, + this OID will show disabled(3)." + ::= { emStatusProbesEntry 11 } + +emStatusProbeMinTempViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + minTempViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum temperature violation status of the probe + temperature reading. This OID will show a minTempViolation(2) + if the current temperature reading shown in the + 'emStatusProbeCurrentTemp' OID is less than or equal to + the minimum temperature threshold value, the + 'emConfigProbeMinTempThreshold' OID, and the value of the + 'emConfigProbeMinTempEnable' OID is enabled. Otherwise it will show + noViolation(1). If the 'emConfigProbeMinTempEnable' OID is disabled, + this OID will show disabled(3)." + ::= { emStatusProbesEntry 12 } + +emStatusProbeMaxHumidViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + maxHumidViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum humidity violation status of the probe humidity + reading. This OID will show a maxTempViolation(2) + if the current humidity reading shown in the + 'emStatusProbeCurrentHumid' OID is greater than or equal to + the maximum humidity threshold value, the + 'emConfigProbeMaxHumidThreshold' OID, and the value of the + 'emConfigProbeMaxHumidEnable' OID is enabled. Otherwise it will + show noViolation(1). If the 'emConfigProbeMaxHumidEnable' OID is + disabled, this OID will show disabled(3)" + ::= { emStatusProbesEntry 13 } + +emStatusProbeMinHumidViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + minHumidViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum humidity violation status of the probe humidity + reading. This OID will show a minTempViolation(2) + if the current humidity reading shown in the + 'emStatusProbeCurrentHumid' OID is less than or equal to + the minimum humidity threshold value, the + 'emConfigProbeMinHumidThreshold' OID, and the value of the + 'emConfigProbeMinHumidEnable' OID is enabled. Otherwise it will + show noViolation(1). If the 'emConfigProbeMinHumidEnable' OID is + disabled, this OID will show disabled(3)." + ::= { emStatusProbesEntry 14 } + +emStatusContactsNumContacts OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of contacts supported by the + Environmental Monitor." + ::= { emStatus 4 } + +emStatusContactsTable OBJECT-TYPE + SYNTAX SEQUENCE OF EmStatusContactsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of contacts supported by the Environmental Monitor + and their status." + ::= { emStatus 5 } + +emStatusContactsEntry OBJECT-TYPE + SYNTAX EmStatusContactsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The status of the contact." + INDEX { emStatusContactNumber } + ::= { emStatusContactsTable 1 } + +EmStatusContactsEntry ::= + SEQUENCE { + emStatusContactNumber + INTEGER, + emStatusContactName + DisplayString, + emStatusContactStatus + INTEGER + } + +emStatusContactNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the Environmental Monitor contact." + ::= { emStatusContactsEntry 1 } + +emStatusContactName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A descriptive name for the Environmental Monitor contact + set by the user, possibly denoting its location or purpose." + ::= { emStatusContactsEntry 2 } + +emStatusContactStatus OBJECT-TYPE + SYNTAX INTEGER { + noFault(1), + fault(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Environmental Monitor contact. The status + will show noFault(1) if the contact is in the normal state + and the 'emConfigContactEnable' OID is enabled. The status will + show a fault(2) if the contact is faulted and the + 'emContactEnable' OID is enabled. If the 'emConfigContactEnable' + OID is disabled, the status will show disabled(3)." + ::= { emStatusContactsEntry 3 } + +-- Modular Environmental Manager (MEM) + +-- MEM Modules Status table + +memModulesStatusTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the memModulesStatusTable." + ::= { memModules 1 } + +memModulesStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF MemModulesStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting status information from the modules + attached to the system." + ::= { memModules 2 } + +memModulesStatusEntry OBJECT-TYPE + SYNTAX MemModulesStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { memModulesStatusModuleNumber } + ::= { memModulesStatusTable 1 } + +MemModulesStatusEntry ::= + SEQUENCE { + memModulesStatusModuleNumber INTEGER, + memModulesStatusModuleName DisplayString, + memModulesStatusModuleLocation DisplayString, + memModulesStatusModelNumber DisplayString, + memModulesStatusSerialNumber DisplayString, + memModulesStatusFirmwareRev DisplayString, + memModulesStatusHardwareRev DisplayString + } + +memModulesStatusModuleNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The module number." + ::= { memModulesStatusEntry 1 } + +memModulesStatusModuleName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The module name." + ::= { memModulesStatusEntry 2 } + +memModulesStatusModuleLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The location of the module." + ::= { memModulesStatusEntry 3 } + +memModulesStatusModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The model number of the module." + ::= { memModulesStatusEntry 4 } + +memModulesStatusSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the module." + ::= { memModulesStatusEntry 5 } + +memModulesStatusFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of the module." + ::= { memModulesStatusEntry 6 } + +memModulesStatusHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision." + ::= { memModulesStatusEntry 7 } + +-- MEM Modules Config table + +memModulesConfigTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the memModulesConfigTable." + ::= { memModules 3 } + +memModulesConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF MemModulesConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting status information from the modules + attached to the system." + ::= { memModules 4 } + +memModulesConfigEntry OBJECT-TYPE + SYNTAX MemModulesConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { memModulesConfigModuleNumber } + ::= { memModulesConfigTable 1 } + +MemModulesConfigEntry ::= + SEQUENCE { + memModulesConfigModuleNumber INTEGER, + memModulesConfigModuleName DisplayString, + memModulesConfigModuleLocation DisplayString + } + +memModulesConfigModuleNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The module number." + ::= { memModulesConfigEntry 1 } + +memModulesConfigModuleName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The module name." + ::= { memModulesConfigEntry 2 } + +memModulesConfigModuleLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The location of the module." + ::= { memModulesConfigEntry 3 } + + +-- MEM Sensor Status Table + +memSensorsStatusSysTempUnits OBJECT-TYPE + SYNTAX INTEGER { + celsius(1), + fahrenheit(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature scale used to display the temperature + in the system, Celsius(1) or Fahrenheit(2). + This setting is based on the system preferences + configuration in the agent." + ::= { memSensors 1 } + +memSensorsStatusTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the memSensorsStatusTable." + ::= { memSensors 2 } + +memSensorsStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF MemSensorsStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting sensor status information." + ::= { memSensors 3 } + +memSensorsStatusEntry OBJECT-TYPE + SYNTAX MemSensorsStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { memSensorsStatusModuleNumber, memSensorsStatusSensorNumber } + ::= { memSensorsStatusTable 1 } + +MemSensorsStatusEntry ::= + SEQUENCE { + memSensorsStatusModuleNumber INTEGER, + memSensorsStatusSensorNumber INTEGER, + memSensorsStatusSensorName DisplayString, + memSensorsStatusSensorLocation DisplayString, + memSensorsTemperature INTEGER, + memSensorsHumidity INTEGER, + memSensorsCommStatus INTEGER, + memSensorsAlarmStatus INTEGER + } + +memSensorsStatusModuleNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of the module that the sensor is attached to." + ::= { memSensorsStatusEntry 1 } + +memSensorsStatusSensorNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of this sensor on the module." + ::= { memSensorsStatusEntry 2 } + +memSensorsStatusSensorName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The sensor name." + ::= { memSensorsStatusEntry 3 } + +memSensorsStatusSensorLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The location of the sensor." + ::= { memSensorsStatusEntry 4 } + +memSensorsTemperature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The sensor's current temperature reading. + Units are displayed in the scale shown in + the memSensorsStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { memSensorsStatusEntry 5 } + +memSensorsHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current humidity reading from the sensor." + ::= { memSensorsStatusEntry 6 } + +memSensorsCommStatus OBJECT-TYPE + SYNTAX INTEGER { + notInstalled(1), + commsOK(2), + commsLost(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The communications status of the sensor." + ::= { memSensorsStatusEntry 7 } + +memSensorsAlarmStatus OBJECT-TYPE + SYNTAX INTEGER { + memNormal(1), + memWarning(2), + memCritical(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The alarm status of the sensor." + ::= { memSensorsStatusEntry 8 } + + +-- MEM Sensor Config Table + +memSensorsConfigTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the memSensorsConfigTable." + ::= { memSensors 4 } + +memSensorsConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF MemSensorsConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting configuration information from + sensors attached to the system." + ::= { memSensors 5 } + +memSensorsConfigEntry OBJECT-TYPE + SYNTAX MemSensorsConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { memSensorsConfigModuleNumber, memSensorsConfigSensorNumber } + ::= { memSensorsConfigTable 1 } + +MemSensorsConfigEntry ::= + SEQUENCE { + memSensorsConfigModuleNumber INTEGER, + memSensorsConfigSensorNumber INTEGER, + memSensorsName DisplayString, + memSensorsLocation DisplayString, + memSensorsAlarmGeneration INTEGER, + memSensorsTempMaxThresh INTEGER, + memSensorsTempHighThresh INTEGER, + memSensorsTempLowThresh INTEGER, + memSensorsTempMinThresh INTEGER, + memSensorsTempThreshHysteresis INTEGER, + memSensorsTempShortDecRateThreshValue INTEGER, + memSensorsTempShortDecRateThreshTime INTEGER, + memSensorsTempShortIncRateThreshValue INTEGER, + memSensorsTempShortIncRateThreshTime INTEGER, + memSensorsTempLongDecRateThreshValue INTEGER, + memSensorsTempLongDecRateThreshTime INTEGER, + memSensorsTempLongIncRateThreshValue INTEGER, + memSensorsTempLongIncRateThreshTime INTEGER, + memSensorsHumidityMaxThresh INTEGER, + memSensorsHumidityHighThresh INTEGER, + memSensorsHumidityLowThresh INTEGER, + memSensorsHumidityMinThresh INTEGER, + memSensorsHumidityThreshHysteresis INTEGER + } + +memSensorsConfigModuleNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of the module that the sensor is attached to." + ::= { memSensorsConfigEntry 1 } + +memSensorsConfigSensorNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of this sensor on the module." + ::= { memSensorsConfigEntry 2 } + +memSensorsName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A descriptive name for the sensor." + ::= { memSensorsConfigEntry 3 } + +memSensorsLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The location of the sensor." + ::= { memSensorsConfigEntry 4 } + +memSensorsAlarmGeneration OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable alarm generation on this sensor." + ::= { memSensorsConfigEntry 5 } + +memSensorsTempMaxThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The temperature at which the MEM will generate a maximum + temperature threshold violation alarm on this sensor. + The temperature scale is based on the memSensorsStatusSysTempUnits OID." + + ::= { memSensorsConfigEntry 6 } + +memSensorsTempHighThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The temperature at which the MEM will generate a high + temperature threshold violation alarm on this sensor. + The temperature scale is based on the memSensorsStatusSysTempUnits OID." + ::= { memSensorsConfigEntry 7 } + +memSensorsTempLowThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The temperature at which the MEM will generate a low + temperature threshold violation alarm on this sensor. + The temperature scale is based on the memSensorsStatusSysTempUnits OID." + ::= { memSensorsConfigEntry 8 } + +memSensorsTempMinThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The temperature at which the MEM will generate a minimum + temperature threshold violation alarm on this sensor. + The temperature scale is based on the memSensorsStatusSysTempUnits OID." + ::= { memSensorsConfigEntry 9 } + +memSensorsTempThreshHysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The change in temperature required to cause a + temperature alarm to change from an active to an inactive state. + The temperature scale is based on the memSensorsStatusSysTempUnits OID." + + ::= { memSensorsConfigEntry 10 } + +memSensorsTempShortDecRateThreshValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of the temperature short-term decreasing rate + time that will cause an alarm to be generated. + The temperature scale is based on the memSensorsStatusSysTempUnits OID." + ::= { memSensorsConfigEntry 11 } + +memSensorsTempShortDecRateThreshTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The time over which the temperature may not decrease + beyond the value specified by the temperature short-term + decreasing rate threshold value." + ::= { memSensorsConfigEntry 12 } + +memSensorsTempShortIncRateThreshValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of the temperature short-term increasing rate + time that will cause an alarm to be generated. + The temperature scale is based on the memSensorsStatusSysTempUnits OID." + ::= { memSensorsConfigEntry 13 } + +memSensorsTempShortIncRateThreshTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The time over which the temperature may not increase + beyond the value specified by the temperature short-term + increasing rate threshold value." + ::= { memSensorsConfigEntry 14 } + +memSensorsTempLongDecRateThreshValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of the temperature long-term decreasing rate + time that will cause an alarm to be generated. + The temperature scale is based on the memSensorsStatusSysTempUnits OID." + ::= { memSensorsConfigEntry 15 } + +memSensorsTempLongDecRateThreshTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The time over which the temperature may not decrease + beyond the value specified by the temperature long-term + decreasing rate threshold value." + ::= { memSensorsConfigEntry 16 } + +memSensorsTempLongIncRateThreshValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of the temperature long-term increasing rate + time that will cause an alarm to be generated. + The temperature scale is based on the memSensorsStatusSysTempUnits OID." + ::= { memSensorsConfigEntry 17 } + +memSensorsTempLongIncRateThreshTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The time over which the temperature may not increase + beyond the value specified by the temperature long-term + increasing rate threshold value." + ::= { memSensorsConfigEntry 18 } + +memSensorsHumidityMaxThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The humidity at which the maximum humidity threshold alarm + will be generated." + ::= { memSensorsConfigEntry 19 } + +memSensorsHumidityHighThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The humidity at which the high humidity threshold alarm + will be generated." + ::= { memSensorsConfigEntry 20 } + +memSensorsHumidityLowThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The humidity at which the low humidity threshold alarm + will be generated." + ::= { memSensorsConfigEntry 21 } + +memSensorsHumidityMinThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The humidity at which the minimum humidity threshold alarm + will be generated." + ::= { memSensorsConfigEntry 22 } + +memSensorsHumidityThreshHysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The change in humidity required to cause an active humidity + alarm to change to the inactive state." + ::= { memSensorsConfigEntry 23 } + + +-- MEM Input Status Table + +memInputsStatusTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the memInputsStatusTable." + ::= { memInputs 1 } + +memInputsStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF MemInputsStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting input status information." + ::= { memInputs 2 } + +memInputsStatusEntry OBJECT-TYPE + SYNTAX MemInputsStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { memInputsStatusModuleNumber, memInputsStatusInputNumber } + ::= { memInputsStatusTable 1 } + +MemInputsStatusEntry ::= + SEQUENCE { + memInputsStatusModuleNumber INTEGER, + memInputsStatusInputNumber INTEGER, + memInputsStatusInputName DisplayString, + memInputsStatusInputLocation DisplayString, + memInputsStatusCurrentState INTEGER, + memInputsStatusCurrentAnalogValue DisplayString, + memInputsStatusAlarmStatus INTEGER, + memInputsCommStatus INTEGER + } + +memInputsStatusModuleNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of the module that the input is attached to." + ::= { memInputsStatusEntry 1 } + +memInputsStatusInputNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of this input on the module." + ::= { memInputsStatusEntry 2 } + +memInputsStatusInputName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input name." + ::= { memInputsStatusEntry 3 } + +memInputsStatusInputLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The location of the input." + ::= { memInputsStatusEntry 4 } + +memInputsStatusCurrentState OBJECT-TYPE + SYNTAX INTEGER { + inputClosedHighMEM (1), + inputOpenLowMEM (2), + inputDisabled (3), + inputStateNotApplicable (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current state of the input. This OID will return + inputStateNotAplicable(4) for analog input types. " + ::= { memInputsStatusEntry 5 } + +memInputsStatusCurrentAnalogValue OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current analog value of the input in the units defined + by the user." + ::= { memInputsStatusEntry 6 } + +memInputsStatusAlarmStatus OBJECT-TYPE + SYNTAX INTEGER { + memNormal(1), + memWarning(2), + memCritical(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The alarm status of the input." + ::= { memInputsStatusEntry 7 } + +memInputsCommStatus OBJECT-TYPE + SYNTAX INTEGER { + notInstalled(1), + commsOK(2), + commsLost(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The communications status of the input. This OID is only supported by NBRK0200." + ::= { memInputsStatusEntry 8 } + +-- MEM Input Config Table + +memInputsConfigTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the memInputsConfigTable." + ::= { memInputs 3 } + +memInputsConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF MemInputsConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting input configuration information." + ::= { memInputs 4 } + +memInputsConfigEntry OBJECT-TYPE + SYNTAX MemInputsConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { memInputsConfigModuleNumber, memInputsConfigInputNumber } + ::= { memInputsConfigTable 1 } + +MemInputsConfigEntry ::= + SEQUENCE { + memInputsConfigModuleNumber INTEGER, + memInputsConfigInputNumber INTEGER, + memInputName DisplayString, + memInputLocation DisplayString, + memInputType INTEGER, + memInputAlarmGeneration INTEGER, + memInputNormalState INTEGER, + memInputAbnormalSeverity INTEGER, + memInputNumberCalibrationPoints INTEGER, + memInputAnalogCalibrationPoint1 DisplayString, + memInputAnalogCalibrationPoint2 DisplayString, + memInputAnalogCalibrationPoint3 DisplayString, + memInputAnalogCalibrationPoint4 DisplayString, + memInputAnalogCalibrationPoint5 DisplayString, + memInputAnalogCalibrationPoint1Value DisplayString, + memInputAnalogCalibrationPoint2Value DisplayString, + memInputAnalogCalibrationPoint3Value DisplayString, + memInputAnalogCalibrationPoint4Value DisplayString, + memInputAnalogCalibrationPoint5Value DisplayString, + memInputAnalogMeasurementUnits DisplayString, + memInputAnalogMaxThresh DisplayString, + memInputAnalogHighThresh DisplayString, + memInputAnalogLowThresh DisplayString, + memInputAnalogMinThresh DisplayString, + memInputAnalogThreshHysteresis DisplayString + } + +memInputsConfigModuleNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of the module that the input is attached to." + ::= { memInputsConfigEntry 1 } + +memInputsConfigInputNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of this input on the module." + ::= { memInputsConfigEntry 2 } + +memInputName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the input." + ::= { memInputsConfigEntry 3 } + +memInputLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The location of the input." + ::= { memInputsConfigEntry 4 } + +memInputType OBJECT-TYPE + SYNTAX INTEGER { + noConnection (1), + dryContact (2), + digital (3), + analogmAmps (4), + analogVolts (5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The type of input this contact will take." + ::= { memInputsConfigEntry 5 } + +memInputAlarmGeneration OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable alarm generation on this input." + ::= { memInputsConfigEntry 6 } + +memInputNormalState OBJECT-TYPE + SYNTAX INTEGER { + inputClosedHighMEM (1), + inputOpenLowMEM (2), + inputDisabled (3), + inputStateNotApplicable (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Defines the normal (no alarm) state of the input." + ::= { memInputsConfigEntry 7 } + +memInputAbnormalSeverity OBJECT-TYPE + SYNTAX INTEGER { + inputSeverityinformational (1), + inputSeveritywarning (2), + inputSeveritysevere (3), + inputSeverityNotApplicable (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Defines the severity of the event that is associated + with the abnormal state of the input. This OID will return + inputSeverityNotApplicable(4) for analog input types. " + ::= { memInputsConfigEntry 8 } + +memInputNumberCalibrationPoints OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of calibration points that are required for + this input." + ::= { memInputsConfigEntry 9 } + +memInputAnalogCalibrationPoint1 OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The electrical value that the input sensor will measure at the + first calibration point. + This OID is relevant only for inputs configured as analog type (ma or V)." + ::= { memInputsConfigEntry 10 } + +memInputAnalogCalibrationPoint2 OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The electrical value that the input sensor will measure at the + second calibration point. + This OID is relevant only for inputs configured as analog type (ma or V)." + ::= { memInputsConfigEntry 11 } + +memInputAnalogCalibrationPoint3 OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The electrical value that the input sensor will measure at the + third calibration point. + This OID is relevant only for inputs configured as analog type (ma or V)." + ::= { memInputsConfigEntry 12 } + +memInputAnalogCalibrationPoint4 OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The electrical value that the input sensor will measure at the + fourth calibration point. + This OID is relevant only for inputs configured as analog type (ma or V)." + ::= { memInputsConfigEntry 13 } + +memInputAnalogCalibrationPoint5 OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The electrical value that the input sensor will measure at the + fifth calibration point. + This OID is relevant only for inputs configured as analog type (ma or V)." + ::= { memInputsConfigEntry 14 } + +memInputAnalogCalibrationPoint1Value OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of the input, in units of measure defined by + the user, that corresponds to the current setting at the + first calibration point." + ::= { memInputsConfigEntry 15 } + +memInputAnalogCalibrationPoint2Value OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of the input, in units of measure defined by + the user, that corresponds to the current setting at the + second calibration point." + ::= { memInputsConfigEntry 16 } + +memInputAnalogCalibrationPoint3Value OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of the input, in units of measure defined by + the user, that corresponds to the current setting at the + third calibration point." + ::= { memInputsConfigEntry 17 } + +memInputAnalogCalibrationPoint4Value OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of the input, in units of measure defined by + the user, that corresponds to the current setting at the + fourth calibration point." + ::= { memInputsConfigEntry 18 } + +memInputAnalogCalibrationPoint5Value OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of the input, in units of measure defined by + the user, that corresponds to the current setting at the + fifth calibration point." + ::= { memInputsConfigEntry 19 } + +memInputAnalogMeasurementUnits OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The units of measure to be used for this input." + ::= { memInputsConfigEntry 20 } + +memInputAnalogMaxThresh OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The input value at which a maximum threshold violation + alarm will be generated on this input." + ::= { memInputsConfigEntry 21 } + +memInputAnalogHighThresh OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The input value at which a high threshold violation + alarm will be generated on this input." + ::= { memInputsConfigEntry 22 } + +memInputAnalogLowThresh OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The input value at which a low threshold violation + alarm will be generated on this input." + ::= { memInputsConfigEntry 23 } + +memInputAnalogMinThresh OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The input value at which a minimum threshold violation + alarm will be generated on this input." + ::= { memInputsConfigEntry 24 } + + +memInputAnalogThreshHysteresis OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The change in value required to cause an alarm on this input + to change from active to inactive." + ::= { memInputsConfigEntry 25 } + + +-- MEM Output Status Table + +memOutputStatusTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the memOutputStatusTable." + ::= { memOutputs 1 } + +memOutputStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF MemOutputStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting output status information." + ::= { memOutputs 2 } + +memOutputStatusEntry OBJECT-TYPE + SYNTAX MemOutputStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { memOutputStatusModuleNumber, memOutputStatusOutputNumber } + ::= { memOutputStatusTable 1 } + +MemOutputStatusEntry ::= + SEQUENCE { + memOutputStatusModuleNumber INTEGER, + memOutputStatusOutputNumber INTEGER, + memOutputStatusOutputName DisplayString, + memOutputStatusOutputLocation DisplayString, + memOutputStatusCurrentState INTEGER + } + +memOutputStatusModuleNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of the module that the output is attached to." + ::= { memOutputStatusEntry 1 } + +memOutputStatusOutputNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of this output on the module." + ::= { memOutputStatusEntry 2 } + +memOutputStatusOutputName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output name." + ::= { memOutputStatusEntry 3 } + +memOutputStatusOutputLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The location of the output." + ::= { memOutputStatusEntry 4 } + +memOutputStatusCurrentState OBJECT-TYPE + SYNTAX INTEGER { + memOutputClosed (1), + memOutputOpen (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the output." + ::= { memOutputStatusEntry 5 } + + +-- MEM Output Config Table + +memOutputConfigTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the memOutputConfigTable." + ::= { memOutputs 3 } + +memOutputConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF MemOutputConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting output configuration information." + ::= { memOutputs 4 } + +memOutputConfigEntry OBJECT-TYPE + SYNTAX MemOutputConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { memOutputConfigModuleNumber, memOutputConfigOutputNumber } + ::= { memOutputConfigTable 1 } + +MemOutputConfigEntry ::= + SEQUENCE { + memOutputConfigModuleNumber INTEGER, + memOutputConfigOutputNumber INTEGER, + memOutputName DisplayString, + memOutputLocation DisplayString, + memOutputNormalState INTEGER, + memOutputAction INTEGER + } + +memOutputConfigModuleNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of the module that the output is attached to." + ::= { memOutputConfigEntry 1 } + +memOutputConfigOutputNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of this output on the module." + ::= { memOutputConfigEntry 2 } + +memOutputName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the output." + ::= { memOutputConfigEntry 3 } + +memOutputLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The location of the output." + ::= { memOutputConfigEntry 4 } + +memOutputNormalState OBJECT-TYPE + SYNTAX INTEGER { + memOutputClosed (1), + memOutputOpen (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The state of the output that will not generate an alarm." + ::= { memOutputConfigEntry 5 } + +memOutputAction OBJECT-TYPE + SYNTAX INTEGER { + memActionClose (1), + memActionOpen (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Manual control actions for the output. SNMP get command will return the state + of the output, SNMP set of this OID controls the output." + ::= { memOutputConfigEntry 6 } + + +-- MEM Outlet Status Table + +memOutletStatusTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the memOutletStatusTable." + ::= { memOutlets 1 } + +memOutletStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF MemOutletStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting outlet status information." + ::= { memOutlets 2 } + +memOutletStatusEntry OBJECT-TYPE + SYNTAX MemOutletStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { memOutletStatusModuleNumber, memOutletStatusOutletNumber } + ::= { memOutletStatusTable 1 } + +MemOutletStatusEntry ::= + SEQUENCE { + memOutletStatusModuleNumber INTEGER, + memOutletStatusOutletNumber INTEGER, + memOutletStatusOutletName DisplayString, + memOutletStatusOutletLocation DisplayString, + memOutletStatusCurrentState INTEGER + } + +memOutletStatusModuleNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of the module that the outlet is attached to." + ::= { memOutletStatusEntry 1 } + +memOutletStatusOutletNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of this outlet on the module." + ::= { memOutletStatusEntry 2 } + +memOutletStatusOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The outlet name." + ::= { memOutletStatusEntry 3 } + +memOutletStatusOutletLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The location of the outlet." + ::= { memOutletStatusEntry 4 } + +memOutletStatusCurrentState OBJECT-TYPE + SYNTAX INTEGER { + off (1), + on (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the outlet." + ::= { memOutletStatusEntry 5 } + + +-- MEM Outlet Config Table + +memOutletConfigTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the memOutletConfigTable." + ::= { memOutlets 3 } + +memOutletConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF MemOutletConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting outlet configuration information." + ::= { memOutlets 4 } + +memOutletConfigEntry OBJECT-TYPE + SYNTAX MemOutletConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { memOutletConfigModuleNumber, memOutletConfigOutletNumber } + ::= { memOutletConfigTable 1 } + +MemOutletConfigEntry ::= + SEQUENCE { + memOutletConfigModuleNumber INTEGER, + memOutletConfigOutletNumber INTEGER, + memOutletName DisplayString, + memOutletLocation DisplayString, + memOutletNormalState INTEGER, + memOutletAction INTEGER + } + +memOutletConfigModuleNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of the module that the Outlet is attached to." + ::= { memOutletConfigEntry 1 } + +memOutletConfigOutletNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of this Outlet on the module." + ::= { memOutletConfigEntry 2 } + +memOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the Outlet." + ::= { memOutletConfigEntry 3 } + +memOutletLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The location of the Outlet." + ::= { memOutletConfigEntry 4 } + +memOutletNormalState OBJECT-TYPE + SYNTAX INTEGER { + off (1), + on (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The state of the Outlet that will not generate an alarm." + ::= { memOutletConfigEntry 5 } + +memOutletAction OBJECT-TYPE + SYNTAX INTEGER { + turnOff (1), + turnOn (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Manual control actions for the Outlet. Get displays state + of outlet, set controls outlet." + ::= { memOutletConfigEntry 6 } + + +-- MEM Beacon Status Table + +memBeaconStatusTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the memBeaconStatusTable." + ::= { memBeacons 1 } + +memBeaconStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF MemBeaconStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting beacon status information." + ::= { memBeacons 2 } + +memBeaconStatusEntry OBJECT-TYPE + SYNTAX MemBeaconStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { memBeaconStatusModuleNumber, memBeaconStatusBeaconNumber } + ::= { memBeaconStatusTable 1 } + +MemBeaconStatusEntry ::= + SEQUENCE { + memBeaconStatusModuleNumber INTEGER, + memBeaconStatusBeaconNumber INTEGER, + memBeaconStatusBeaconName DisplayString, + memBeaconStatusBeaconLocation DisplayString, + memBeaconStatusCurrentState INTEGER + } + +memBeaconStatusModuleNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of the module that the beacon is attached to." + ::= { memBeaconStatusEntry 1 } + +memBeaconStatusBeaconNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of this beacon on the module." + ::= { memBeaconStatusEntry 2 } + +memBeaconStatusBeaconName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The beacon name." + ::= { memBeaconStatusEntry 3 } + +memBeaconStatusBeaconLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The location of the beacon." + ::= { memBeaconStatusEntry 4 } + +memBeaconStatusCurrentState OBJECT-TYPE + SYNTAX INTEGER { + off (1), + on (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the beacon." + ::= { memBeaconStatusEntry 5 } + + +-- MEM Beacon Config Table + +memBeaconConfigTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the memBeaconConfigTable." + ::= { memBeacons 3 } + +memBeaconConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF MemBeaconConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting beacon configuration information." + ::= { memBeacons 4 } + +memBeaconConfigEntry OBJECT-TYPE + SYNTAX MemBeaconConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { memBeaconConfigModuleNumber, memBeaconConfigBeaconNumber } + ::= { memBeaconConfigTable 1 } + +MemBeaconConfigEntry ::= + SEQUENCE { + memBeaconConfigModuleNumber INTEGER, + memBeaconConfigBeaconNumber INTEGER, + memBeaconConfigName DisplayString, + memBeaconConfigLocation DisplayString, + memBeaconAction INTEGER + } + +memBeaconConfigModuleNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of the module that the beacon is attached to." + ::= { memBeaconConfigEntry 1 } + +memBeaconConfigBeaconNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of this beacon on the module." + ::= { memBeaconConfigEntry 2 } + +memBeaconConfigName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the beacon." + ::= { memBeaconConfigEntry 3 } + +memBeaconConfigLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The location of the beacon." + ::= { memBeaconConfigEntry 4 } + +memBeaconAction OBJECT-TYPE + SYNTAX INTEGER { + turnOff (1), + turnOn (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Control action (on/off) for the beacon. Setting this OID will turn the + beacon on/off. Getting this OID will respond with the current state." + ::= { memBeaconConfigEntry 5 } + + +-- Integrated Environmental Monitor (IEM) + +iemIdentHardwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the Integrated Environmental + Monitor." + ::= { iemIdent 1 } + +iemConfigProbesNumProbes OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of temperature and humidity probes available." + ::= { iemConfig 1 } + +iemConfigProbesTable OBJECT-TYPE + SYNTAX SEQUENCE OF IemConfigProbesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of probes supported by the Environmental Monitor + and their configurations." + ::= { iemConfig 2 } + +iemConfigProbesEntry OBJECT-TYPE + SYNTAX IemConfigProbesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The Environmental Monitor probe configurations." + INDEX { iemConfigProbeNumber } + ::= { iemConfigProbesTable 1 } + +IemConfigProbesEntry ::= + SEQUENCE { + iemConfigProbeNumber + INTEGER, + iemConfigProbeName + DisplayString, + iemConfigProbeHighTempThreshold + INTEGER, + iemConfigProbeLowTempThreshold + INTEGER, + iemConfigProbeTempUnits + INTEGER, + iemConfigProbeHighHumidThreshold + INTEGER, + iemConfigProbeLowHumidThreshold + + INTEGER, + iemConfigProbeHighTempEnable + INTEGER, + iemConfigProbeLowTempEnable + INTEGER, + iemConfigProbeHighHumidEnable + INTEGER, + iemConfigProbeLowHumidEnable + INTEGER, + iemConfigProbeMaxTempThreshold + INTEGER, + iemConfigProbeMinTempThreshold + INTEGER, + iemConfigProbeMaxHumidThreshold + INTEGER, + iemConfigProbeMinHumidThreshold + INTEGER, + iemConfigProbeMaxTempEnable + INTEGER, + iemConfigProbeMinTempEnable + INTEGER, + iemConfigProbeMaxHumidEnable + INTEGER, + iemConfigProbeMinHumidEnable + INTEGER, + iemConfigProbeTempHysteresis + INTEGER, + iemConfigProbeHumidHysteresis + INTEGER, + iemConfigProbeLocation + DisplayString + } + +iemConfigProbeNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to a Environmental Monitor probe entry." + ::= { iemConfigProbesEntry 1 } + +iemConfigProbeName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A descriptive name for the probe set by the user, + possibly denoting its location or purpose." + ::= { iemConfigProbesEntry 2 } + +iemConfigProbeHighTempThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The high temperature alarm threshold for the probe. + Units are displayed in the scale selected in the + 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit)." + ::= { iemConfigProbesEntry 3 } + +iemConfigProbeLowTempThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low temperature alarm threshold for the probe. + Units are displayed in the scale selected in the + 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit)." + ::= { iemConfigProbesEntry 4 } + +iemConfigProbeTempUnits OBJECT-TYPE + SYNTAX INTEGER { + celsius(1), + fahrenheit(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature scale used to display the temperature + thresholds of the probe, Celsius(1) or Fahrenheit(2). + This setting is based on the system preferences + configuration in the agent." + ::= { iemConfigProbesEntry 5 } + +iemConfigProbeHighHumidThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The high humidity alarm threshold for the probe in + percent relative humidity." + ::= { iemConfigProbesEntry 6 } + +iemConfigProbeLowHumidThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low humidity alarm threshold for the probe in + percent relative humidity." + ::= { iemConfigProbesEntry 7 } + +iemConfigProbeHighTempEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The high temperature alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { iemConfigProbesEntry 8 } + +iemConfigProbeLowTempEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low temperature alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { iemConfigProbesEntry 9 } + +iemConfigProbeHighHumidEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The high humidity alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { iemConfigProbesEntry 10 } + +iemConfigProbeLowHumidEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low humidity alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { iemConfigProbesEntry 11 } + +iemConfigProbeMaxTempThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximun temperature alarm threshold for the probe. + Units are displayed in the scale selected in the + 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit)." + ::= { iemConfigProbesEntry 12 } + +iemConfigProbeMinTempThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The minimun temperature alarm threshold for the probe. + Units are displayed in the scale selected in the + 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit)." + ::= { iemConfigProbesEntry 13 } + +iemConfigProbeMaxHumidThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum humidity alarm threshold for the probe in + percent relative humidity." + ::= { iemConfigProbesEntry 14 } + +iemConfigProbeMinHumidThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The minimum humidity alarm threshold for the probe in + percent relative humidity." + ::= { iemConfigProbesEntry 15 } + +iemConfigProbeMaxTempEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum temperature alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { iemConfigProbesEntry 16 } + +iemConfigProbeMinTempEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low temperature alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { iemConfigProbesEntry 17 } + +iemConfigProbeMaxHumidEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum humidity alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { iemConfigProbesEntry 18 } + +iemConfigProbeMinHumidEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The minimum humidity alarm enable/disable for the + probe. No alarm will be generated if this value + is set to disabled(1). The alarm will be + generated if this value is set to enabled(2) and + the threshold has been violated." + ::= { iemConfigProbesEntry 19 } + +iemConfigProbeTempHysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of degrees beyond the temperature thresholds + at which an active temperature alarm will be cleared. + This configuration setting applies to all temperature + thresholds. + Units are displayed in the scale selected in + the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)." + ::= { iemConfigProbesEntry 20 } + +iemConfigProbeHumidHysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of percent RH points beyond the humidity + thresholds at which an active humidity alarm will be + cleared. This configuration setting applies to all + humidity thresholds. + Units are displayed in the scale selected in + the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)." + ::= { iemConfigProbesEntry 21 } + +iemConfigProbeLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A string describing the location of the probe." + ::= { iemConfigProbesEntry 22 } + +iemConfigContactsNumContacts OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of contacts available on the Environmental + Monitor." + ::= { iemConfig 3 } + +iemConfigContactsTable OBJECT-TYPE + SYNTAX SEQUENCE OF IemConfigContactsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of contacts supported by the Environmental Monitor + and their configurations." + ::= { iemConfig 4 } + +iemConfigContactsEntry OBJECT-TYPE + SYNTAX IemConfigContactsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The Environmental Monitor contact configurations." + INDEX { iemConfigContactNumber } + ::= { iemConfigContactsTable 1 } + +IemConfigContactsEntry ::= + SEQUENCE { + iemConfigContactNumber + INTEGER, + iemConfigContactName + DisplayString, + iemConfigContactEnable + INTEGER, + iemConfigContactSeverity + INTEGER, + iemConfigContactNormalState + INTEGER, + iemConfigContactLocation + DisplayString + } + +iemConfigContactNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of an Environmental Monitor contact." + ::= { iemConfigContactsEntry 1 } + +iemConfigContactName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A descriptive name for the Environmental Monitor contact + set by the user, possibly denoting its location or purpose." + ::= { iemConfigContactsEntry 2 } + +iemConfigContactEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "An Environmental Monitor contact alarm enable/disable." + ::= { iemConfigContactsEntry 3 } + +iemConfigContactSeverity OBJECT-TYPE + SYNTAX INTEGER { + critical(1), + warning(2), + informational(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The severtity of the alarm that will be triggered when + the input contact is activated. The alarms can be + critical(1), warning(2) or informational(3). + NOTE: informational(3) is deprecated (and no longer valid) for this OID." + ::= { iemConfigContactsEntry 4 } + +iemConfigContactNormalState OBJECT-TYPE + SYNTAX INTEGER { + open(1), + closed(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The contact state that will be considered normal, i.e. + will not trigger an alarm. The states are open(1) or + closed(2)." + ::= { iemConfigContactsEntry 5 } + +iemConfigContactLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A descriptive label for the contact denoting its + location or purpose." + ::= { iemConfigContactsEntry 6 } + +iemConfigConfigRelaysNumRelays OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of output relays supported by the Environmental + Monitor." + ::= { iemConfig 5 } + + +iemConfigRelaysTable OBJECT-TYPE + SYNTAX SEQUENCE OF IemConfigRelaysEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of output relays supported by the Environmental Monitor + and their configurations." + ::= { iemConfig 6 } + +iemConfigRelaysEntry OBJECT-TYPE + SYNTAX IemConfigRelaysEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The Environmental Monitor output relay configurations." + INDEX { iemConfigRelayNumber } + ::= { iemConfigRelaysTable 1 } + +IemConfigRelaysEntry ::= + SEQUENCE { + iemConfigRelayNumber + INTEGER, + iemConfigRelayName + DisplayString, + iemConfigRelayNormalState + INTEGER, + iemConfigRelayFaultCondition + INTEGER + } + +iemConfigRelayNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of an Environmental Monitor output relay." + ::= { iemConfigRelaysEntry 1 } + +iemConfigRelayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A descriptive name of an Environmental Monitor output relay, + set by the user, describing its location or purpose." + ::= { iemConfigRelaysEntry 2 } + +iemConfigRelayNormalState OBJECT-TYPE + SYNTAX INTEGER { + open(1), + closed(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal state (non-fault state) of an Environmental + Monitor output relay, either open(1) or closed(2)." + ::= { iemConfigRelaysEntry 3 } + +iemConfigRelayFaultCondition OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The fault condition used to activate the output relay." + ::= { iemConfigRelaysEntry 4 } + +iemStatusProbesNumProbes OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of available probes on the Environmental + Monitor." + ::= { iemStatus 1 } + +iemStatusProbesTable OBJECT-TYPE + SYNTAX SEQUENCE OF IemStatusProbesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of probes supported by the Environmental Monitor + and their status." + ::= { iemStatus 2 } + +iemStatusProbesEntry OBJECT-TYPE + SYNTAX IemStatusProbesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The status of the probe." + INDEX { iemStatusProbeNumber } + ::= { iemStatusProbesTable 1 } + +IemStatusProbesEntry ::= + SEQUENCE { + iemStatusProbeNumber + INTEGER, + iemStatusProbeName + DisplayString, + iemStatusProbeStatus + INTEGER, + iemStatusProbeCurrentTemp + INTEGER, + iemStatusProbeTempUnits + INTEGER, + iemStatusProbeCurrentHumid + INTEGER, + iemStatusProbeHighTempViolation + INTEGER, + iemStatusProbeLowTempViolation + INTEGER, + iemStatusProbeHighHumidViolation + INTEGER, + iemStatusProbeLowHumidViolation + INTEGER, + iemStatusProbeMaxTempViolation + INTEGER, + iemStatusProbeMinTempViolation + INTEGER, + iemStatusProbeMaxHumidViolation + INTEGER, + iemStatusProbeMinHumidViolation + INTEGER, + iemStatusProbeLocation + DisplayString + } + +iemStatusProbeNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the probe." + ::= { iemStatusProbesEntry 1 } + +iemStatusProbeName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A descriptive name for the probe set by the user." + ::= { iemStatusProbesEntry 2 } + +iemStatusProbeStatus OBJECT-TYPE + SYNTAX INTEGER { + disconnected(1), + connected(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The connected status of the probe, either + disconnected(1) or connected(2)." + ::= { iemStatusProbesEntry 3 } + +iemStatusProbeCurrentTemp OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current temperature reading from the probe displayed + in the units shown in the 'iemStatusProbeTempUnits' OID + (Celsius or Fahrenheit)." + ::= { iemStatusProbesEntry 4 } + +iemStatusProbeTempUnits OBJECT-TYPE + SYNTAX INTEGER { + celsius(1), + fahrenheit(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature scale used to display the temperature + thresholds of the probe, Celsius(1) or Fahrenheit(2). + This setting is based on the system preferences + configuration in the agent." + ::= { iemStatusProbesEntry 5 } + +iemStatusProbeCurrentHumid OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current humidity reading from the probe in percent + relative humidity." + ::= { iemStatusProbesEntry 6 } + +iemStatusProbeHighTempViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + highTempViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The high temperature violation status of the probe + temperature reading. This OID will show a highTempViolation(2) + if the current temperature reading shown in the + 'iemStatusProbeCurrentTemp' OID is greater than or equal to + the high temperature threshold value, the + 'iemConfigProbeHighTempThreshold' OID, and the value of the + 'iemConfigProbeHighTempEnable' OID is enabled. Otherwise it will show + noViolation(1). If the 'iemConfigProbeHighTempEnable' OID is disabled, + this OID will show disabled(3)." + ::= { iemStatusProbesEntry 7 } + +iemStatusProbeLowTempViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + lowTempViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The high temperature violation status of the probe + temperature reading. This OID will show a lowTempViolation(2) + if the current temperature reading shown in the + 'iemStatusProbeCurrentTemp' OID is less than or equal to + the low temperature threshold value, the + 'iemConfigProbeLowTempThreshold' OID, and the value of the + 'iemPConfigrobeLowTempEnable' OID is enabled. Otherwise it will show + noViolation(1). If the 'iemConfigProbeLowTempEnable' OID is disabled, + this OID will show disabled(3)." + ::= { iemStatusProbesEntry 8 } + +iemStatusProbeHighHumidViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + highHumidViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The high humidity violation status of the probe humidity + reading. This OID will show a highTempViolation(2) + if the current humidity reading shown in the + 'iemStatusProbeCurrentHumid' OID is greater than or equal to + the high humidity threshold value, the + 'iemConfigProbeHighHumidThreshold' OID, and the value of the + 'iemConfigProbeHighHumidEnable' OID is enabled. Otherwise it will + show noViolation(1). If the 'iemConfigProbeHighHumidEnable' OID is + disabled, this OID will show disabled(3)." + ::= { iemStatusProbesEntry 9 } + +iemStatusProbeLowHumidViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + lowHumidViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The low humidity violation status of the probe humidity + reading. This OID will show a lowTempViolation(2) + if the current humidity reading shown in the + 'iemStatusProbeCurrentHumid' OID is less than or equal to + the low humidity threshold value, the + 'iemConfigProbeLowHumidThreshold' OID, and the value of the + 'iemConfigProbeLowHumidEnable' OID is enabled. Otherwise it will + show noViolation(1). If the 'iemConfigProbeLowHumidEnable' OID is + disabled, this OID will show disabled(3)." + ::= { iemStatusProbesEntry 10 } + +iemStatusProbeMaxTempViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + maxTempViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The max temperature violation status of the probe + temperature reading. This OID will show a maxTempViolation(2) + if the current temperature reading shown in the + 'iemStatusProbeCurrentTemp' OID is greater than or equal to + the maximun temperature threshold value, the + 'iemConfigProbeMaxTempThreshold' OID, and the value of the + 'iemConfigProbeMaxTempEnable' OID is enabled. Otherwise it will show + noViolation(1). If the 'iemConfigProbeMaxTempEnable' OID is disabled, + this OID will show disabled(3)." + ::= { iemStatusProbesEntry 11 } + +iemStatusProbeMinTempViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + minTempViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum temperature violation status of the probe + temperature reading. This OID will show a minTempViolation(2) + if the current temperature reading shown in the + 'iemStatusProbeCurrentTemp' OID is less than or equal to + the minimum temperature threshold value, the + 'iemConfigProbeMinTempThreshold' OID, and the value of the + 'iemConfigProbeMinTempEnable' OID is enabled. Otherwise it will show + noViolation(1). If the 'iemConfigProbeMinTempEnable' OID is disabled, + this OID will show disabled(3)." + ::= { iemStatusProbesEntry 12 } + +iemStatusProbeMaxHumidViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + maxHumidViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum humidity violation status of the probe humidity + reading. This OID will show a maxTempViolation(2) + if the current humidity reading shown in the + 'iemStatusProbeCurrentHumid' OID is greater than or equal to + the maximum humidity threshold value, the + 'iemConfigProbeMaxHumidThreshold' OID, and the value of the + 'iemConfigProbeMaxHumidEnable' OID is enabled. Otherwise it will + show noViolation(1). If the 'iemConfigProbeMaxHumidEnable' OID is + disabled, this OID will show disabled(3)" + ::= { iemStatusProbesEntry 13 } + +iemStatusProbeMinHumidViolation OBJECT-TYPE + SYNTAX INTEGER { + noViolation(1), + minHumidViolation(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum humidity violation status of the probe humidity + reading. This OID will show a minTempViolation(2) + if the current humidity reading shown in the + 'iemStatusProbeCurrentHumid' OID is less than or equal to + the minimum humidity threshold value, the + 'iemConfigProbeMinHumidThreshold' OID, and the value of the + 'iemConfigProbeMinHumidEnable' OID is enabled. Otherwise it will + show noViolation(1). If the 'iemConfigProbeMinHumidEnable' OID is + disabled, this OID will show disabled(3)." + ::= { iemStatusProbesEntry 14 } + +iemStatusProbeLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A descriptive location for the probe set by the user." + ::= { iemStatusProbesEntry 15 } + +iemStatusContactsNumContacts OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of contacts supported on the + Environmental Monitor." + ::= { iemStatus 3 } + +iemStatusContactsTable OBJECT-TYPE + SYNTAX SEQUENCE OF IemStatusContactsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of contacts supported by the Environmental Monitor + and their status." + ::= { iemStatus 4 } + +iemStatusContactsEntry OBJECT-TYPE + SYNTAX IemStatusContactsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The status of the contact." + INDEX { iemStatusContactNumber } + ::= { iemStatusContactsTable 1 } + +IemStatusContactsEntry ::= + SEQUENCE { + iemStatusContactNumber + INTEGER, + iemStatusContactName + DisplayString, + iemStatusContactStatus + INTEGER + } + +iemStatusContactNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the Environmental Monitor contact." + ::= { iemStatusContactsEntry 1 } + +iemStatusContactName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A descriptive name for the Environmental Monitor contact + set by the user, denoting its location or purpose." + ::= { iemStatusContactsEntry 2 } + +iemStatusContactStatus OBJECT-TYPE + SYNTAX INTEGER { + noFault(1), + fault(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the Environmental Monitor contact. The status + will show noFault(1) if the contact is in the normal state + and the 'iemConfigContactEnable' OID is enabled. The status will + show a fault(2) if the contact is faulted and the + 'iemConfigContactEnable' OID is enabled. If the + 'iemConfigContactEnable' OID is disabled, the status will show + disabled(3)." + ::= { iemStatusContactsEntry 3 } + +iemStatusRelaysNumRelays OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of output relays supported on the + Environmental Monitor." + ::= { iemStatus 6 } + +iemStatusRelaysTable OBJECT-TYPE + SYNTAX SEQUENCE OF IemStatusRelaysEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of output relays supported by the + Environmental Monitor and their status." + ::= { iemStatus 7 } + +iemStatusRelaysEntry OBJECT-TYPE + SYNTAX IemStatusRelaysEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The status of the relay." + INDEX { iemStatusRelayNumber } + ::= { iemStatusRelaysTable 1 } + +IemStatusRelaysEntry ::= + SEQUENCE { + iemStatusRelayNumber + INTEGER, + iemStatusRelayName + DisplayString, + iemStatusRelayStatus + INTEGER + } + +iemStatusRelayNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the output relay." + ::= { iemStatusRelaysEntry 1 } + +iemStatusRelayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A descriptive name for the output relay set by the + user, denoting its location or purpose." + ::= { iemStatusRelaysEntry 2 } + +iemStatusRelayStatus OBJECT-TYPE + SYNTAX INTEGER { + faultState(1), + normalState(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the output relay, either faultState(1) or + normalState(2)." + ::= { iemStatusRelaysEntry 3 } + +-- Environmental Management System (EMS) + +-- EMS IDENT + +emsIdentEMSName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + device. " + ::= { emsIdent 1 } + +emsIdentProductNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the model number of + the device. This value is set at the factory." + ::= { emsIdent 2 } + +emsIdentFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision of the device." + ::= { emsIdent 3 } + +emsIdentHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the device. + This value is set at the factory." + ::= { emsIdent 4 } + +emsIdentDateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date when the device was manufactured in mm/dd/yyyy format. + This value is set at the factory. " + ::= { emsIdent 5 } + +emsIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the serial number of + the device. This value is set at the factory." + ::= { emsIdent 6 } + +-- EMS CONTROL + +-- EMS OUTPUT RELAY CONTROL STATUS TABLE + +emsOutputRelayControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF EmsOutputRelayControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for control of individual output relays. The number of + entries is contained in the emsStatusOutputRelayCount OID." + ::= { emsOutputRelayControl 1 } + +emsOutputRelayControlEntry OBJECT-TYPE + SYNTAX EmsOutputRelayControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The output relays to control." + INDEX { emsOutputRelayControlOutputRelayIndex } + ::= { emsOutputRelayControlTable 1 } + +EmsOutputRelayControlEntry ::= + SEQUENCE { + emsOutputRelayControlOutputRelayIndex INTEGER, + emsOutputRelayControlOutputRelayName DisplayString, + emsOutputRelayControlOutputRelayCommand INTEGER + } + +emsOutputRelayControlOutputRelayIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the output relay entry." + ::= { emsOutputRelayControlEntry 1 } + +emsOutputRelayControlOutputRelayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the output relay. + This OID is provided for informational purposes only." + ::= { emsOutputRelayControlEntry 2 } + +emsOutputRelayControlOutputRelayCommand OBJECT-TYPE + SYNTAX INTEGER { + immediateCloseEMS (1), + immediateOpenEMS (2) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this variable will return the output relay state. If + the output relay is closed, the immediateCloseEMS (1) value will be returned. + If the output relay is open, the immediateOpenEMS (2) value will be + returned. + + Setting this variable to immediateCloseEMS (1) will immediately close the relay. + + Setting this variable to immediateOpenEMS (2) will immediately open the relay." + ::= { emsOutputRelayControlEntry 3 } + +-- EMS OUTLET CONTROL TABLE + +emsOutletControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF EmsOutletControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for control of individual outlet switches. The number of + entries is contained in the emsStatusOutletCount OID." + ::= { emsOutletControl 1 } + +emsOutletControlEntry OBJECT-TYPE + SYNTAX EmsOutletControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlets to control." + INDEX { emsOutletControlOutletIndex } + ::= { emsOutletControlTable 1 } + +EmsOutletControlEntry ::= + SEQUENCE { + emsOutletControlOutletIndex INTEGER, + emsOutletControlOutletName DisplayString, + emsOutletControlOutletCommand INTEGER + } + +emsOutletControlOutletIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { emsOutletControlEntry 1 } + +emsOutletControlOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the outlet. + This OID is provided for informational purposes only." + ::= { emsOutletControlEntry 2 } + +emsOutletControlOutletCommand OBJECT-TYPE + SYNTAX INTEGER { + immediateOnEMS (1), + immediateOffEMS (2) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this variable will return the outlet state. If + the outlet is on, the immediateOnEMS (1) value will be returned. + If the outlet is off, the immediateOffEMS (2) value will be + returned. + + Setting this variable to immediateOnEMS (1) will immediately turn the outlet on. + + Setting this variable to immediateOffEMS (2) will immediately turn the outlet off." + ::= { emsOutletControlEntry 3 } + +-- EMS SENSOR CONTROL TABLE + +emsSensorControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF EMSSensorControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for control/reset of individual sensors. The number of + entries is contained in the emsStatusSensorCount OID." + ::= { emsSensorControl 1 } + +emsSensorControlEntry OBJECT-TYPE + SYNTAX EMSSensorControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The sensors to control/reset." + INDEX { emsSensorControlSensorIndex } + ::= { emsSensorControlTable 1 } + +EMSSensorControlEntry ::= + SEQUENCE { + emsSensorControlSensorIndex INTEGER, + emsSensorControlSensorSystemName DisplayString, + emsSensorControlSensorUserName DisplayString, + emsSensorControlSensorCommand INTEGER + } + +emsSensorControlSensorIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the sensor entry." + ::= { emsSensorControlEntry 1 } + +emsSensorControlSensorSystemName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system name of the sensor. This describes the hardware system + intent of this sensor." + ::= { emsSensorControlEntry 2 } + +emsSensorControlSensorUserName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the sensor as given by the system user." + ::= { emsSensorControlEntry 3 } + +emsSensorControlSensorCommand OBJECT-TYPE + SYNTAX INTEGER { + noCommandEMS (1), + resetCommandEMS (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this variable will return noCommandEMS(1). + + Setting this variable to resetCommandEMS(2) will issue a reset command to the + sensor. Some sensors cannot be manually reset and will not be affected + by this command." + ::= { emsSensorControlEntry 4 } + +-- EMS ALARM DEVICE CONTROL TABLE + +emsAlarmDeviceControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF EmsAlarmDeviceControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for control of individual alarm devices. + Note: Some alarm devices are not controllable. The number of + entries is contained in the emsStatusAlarmDeviceCount OID." + ::= { emsAlarmDeviceControl 1 } + +emsAlarmDeviceControlEntry OBJECT-TYPE + SYNTAX EmsAlarmDeviceControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The alarm devices to control." + INDEX { emsAlarmDeviceControlDeviceIndex } + ::= { emsAlarmDeviceControlTable 1 } + +EmsAlarmDeviceControlEntry ::= + SEQUENCE { + emsAlarmDeviceControlDeviceIndex INTEGER, + emsAlarmDeviceControlDeviceName DisplayString, + emsAlarmDeviceControlDeviceCommand INTEGER + } + +emsAlarmDeviceControlDeviceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the alarm device entry." + ::= { emsAlarmDeviceControlEntry 1 } + +emsAlarmDeviceControlDeviceName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the alarm device. + This OID is provided for informational purposes only." + ::= { emsAlarmDeviceControlEntry 2 } + +emsAlarmDeviceControlDeviceCommand OBJECT-TYPE + SYNTAX INTEGER { + alarmDeviceOnEMS (1), + alarmDeviceOffEMS (2), + alarmDeviceNotInstalledEMS (3) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this variable will return the device state. If + the device is active, the alarmDeviceOnEMS (1) value will be returned. + If the device is inactive, the alarmDeviceOffEMS (2) value will be + returned. If the device is not installed, the + alarmDeviceNotInstalledEMS (3) value will be returned. + + Actions resulting from setting this variable are device-dependent. + + Setting this variable to alarmDeviceOnEMS (1) will turn that device (ex. Beacon) on. + Setting this variable to alarmDeviceOffEMS (2) will turn that device off." + + ::= { emsAlarmDeviceControlEntry 3 } + + +-- EMS CONFIG + +emsConfigName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the device." + ::= { emsConfig 1 } + +emsConfigCheckLogLight OBJECT-TYPE + SYNTAX INTEGER { + lightDisabled (1), + lightOnInformational (2), + lightOnWarning (3), + lightOnSevere (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The setting of this OID determines the level of event that will + trigger the check-log light on the EMS. This is not available on the EMU2. + + lightDisabled (1) disables the check-log light. + lightOnInformational (2) lights check-log for any event of + informational severity or above. + lightOnWarning (3) lights check-log for any event of + warning severity or above. + lightOnSevere (4) lights check-log for any event of severe severity." + + ::= { emsConfig 2 } + +-- EMS PROBE CONFIG TABLE + +emsProbeConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF EMSProbeConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of individual probes. The number of + entries is contained in the emsStatusProbeCount OID." + ::= { emsProbeConfig 1 } + +emsProbeConfigEntry OBJECT-TYPE + SYNTAX EMSProbeConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The probes to configure." + INDEX { emsProbeConfigProbeIndex } + ::= { emsProbeConfigTable 1 } + +EMSProbeConfigEntry ::= + SEQUENCE { + emsProbeConfigProbeIndex INTEGER, + emsProbeConfigProbeName DisplayString, + emsProbeConfigProbeHighTempThresh INTEGER, + emsProbeConfigProbeLowTempThresh INTEGER, + emsProbeConfigProbeHighHumidityThresh INTEGER, + emsProbeConfigProbeLowHumidityThresh INTEGER, + emsProbeConfigProbeMaxTempThresh INTEGER, + emsProbeConfigProbeMinTempThresh INTEGER, + emsProbeConfigProbeDeltaTemp INTEGER, + emsProbeConfigProbeMaxHumidityThresh INTEGER, + emsProbeConfigProbeMinHumidityThresh INTEGER, + emsProbeConfigProbeDeltaHumidity INTEGER, + emsProbeConfigProbeSTIncTempVariance INTEGER, + emsProbeConfigProbeSTIncTempTime INTEGER, + emsProbeConfigProbeSTDecTempVariance INTEGER, + emsProbeConfigProbeSTDecTempTime INTEGER, + emsProbeConfigProbeLTIncTempVariance INTEGER, + emsProbeConfigProbeLTIncTempTime INTEGER, + emsProbeConfigProbeLTDecTempVariance INTEGER, + emsProbeConfigProbeLTDecTempTime INTEGER + } + +emsProbeConfigProbeIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the probe entry." + ::= { emsProbeConfigEntry 1 } + +emsProbeConfigProbeName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the probe." + ::= { emsProbeConfigEntry 2 } + +emsProbeConfigProbeHighTempThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe high temperature threshold. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the emsStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { emsProbeConfigEntry 3 } + +emsProbeConfigProbeLowTempThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe low temperature threshold. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the emsStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { emsProbeConfigEntry 4 } + +emsProbeConfigProbeHighHumidityThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe high humidity threshold. + + Values are represented in whole number percentage." + ::= { emsProbeConfigEntry 5 } + +emsProbeConfigProbeLowHumidityThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe low humidity threshold. + + Values are represented in whole number percentage." + ::= { emsProbeConfigEntry 6 } + +emsProbeConfigProbeMaxTempThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe maximum temperature threshold. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the emsStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { emsProbeConfigEntry 7 } + +emsProbeConfigProbeMinTempThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe minimum temperature threshold. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the emsStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { emsProbeConfigEntry 8 } + +emsProbeConfigProbeDeltaTemp OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe delta temperature. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the emsStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { emsProbeConfigEntry 9 } + +emsProbeConfigProbeMaxHumidityThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe maximum humidity threshold. + + Values are represented in whole number percentage." + ::= { emsProbeConfigEntry 10 } + +emsProbeConfigProbeMinHumidityThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe minimum humidity threshold. + + Values are represented in whole number percentage." + ::= { emsProbeConfigEntry 11 } + +emsProbeConfigProbeDeltaHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe delta humidity. + + Values are represented in whole number percentage." + ::= { emsProbeConfigEntry 12 } + +emsProbeConfigProbeSTIncTempVariance OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe short-term increasing temperature variance used for rate of change alarms. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the emsStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { emsProbeConfigEntry 13 } + +emsProbeConfigProbeSTIncTempTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe short-term increasing temperature time used for rate of change alarms. + + Values are represented in whole number minutes." + ::= { emsProbeConfigEntry 14 } + +emsProbeConfigProbeSTDecTempVariance OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe short-term decreasing temperature variance used for rate of change alarms. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the emsStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { emsProbeConfigEntry 15 } + +emsProbeConfigProbeSTDecTempTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe short-term decreasing temperature time used for rate of change alarms. + + Values are represented in whole number minutes." + ::= { emsProbeConfigEntry 16 } + +emsProbeConfigProbeLTIncTempVariance OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe long-term increasing temperature variance used for rate of change alarms. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the emsStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { emsProbeConfigEntry 17 } + +emsProbeConfigProbeLTIncTempTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe long-term increasing temperature time used for rate of change alarms. + + Values are represented in whole number hours." + ::= { emsProbeConfigEntry 18 } + +emsProbeConfigProbeLTDecTempVariance OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe long-term decreasing temperature variance used for rate of change alarms. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the emsStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { emsProbeConfigEntry 19 } + +emsProbeConfigProbeLTDecTempTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Probe long-term decreasing temperature time used for rate of change alarms. + + Values are represented in whole number hours." + ::= { emsProbeConfigEntry 20 } + + +-- EMS INPUT CONTACT CONFIG STATUS TABLE + +emsInputContactConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF EMSInputContactConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of individual input contacts. The number of + entries is contained in the emsStatusInputContactCount OID." + ::= { emsInputContactConfig 1 } + +emsInputContactConfigEntry OBJECT-TYPE + SYNTAX EMSInputContactConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The input contacts to configure." + INDEX { emsInputContactConfigInputContactIndex } + ::= { emsInputContactConfigTable 1 } + +EMSInputContactConfigEntry ::= + SEQUENCE { + emsInputContactConfigInputContactIndex INTEGER, + emsInputContactConfigInputContactName DisplayString, + emsInputContactConfigInputContactNormalState INTEGER + } + +emsInputContactConfigInputContactIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the input contact entry." + ::= { emsInputContactConfigEntry 1 } + +emsInputContactConfigInputContactName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the input contact." + ::= { emsInputContactConfigEntry 2 } + +emsInputContactConfigInputContactNormalState OBJECT-TYPE + SYNTAX INTEGER { + normallyClosedEMS (1), + normallyOpenEMS (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this variable will return the normal state of the input contact. If + the normal state is closed, the normallyClosedEMS (1) value will be returned. + If the normal state is closed, the normallyOpenEMS (2) value will be + returned. + + Setting this variable will change the normal state of the input contact" + ::= { emsInputContactConfigEntry 3 } + +-- EMS OUTPUT RELAY CONFIG STATUS TABLE + +emsOutputRelayConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF EMSOutputRelayConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of individual output relays. The number of + entries is contained in the emsStatusOutputRelayCount OID." + ::= { emsOutputRelayConfig 1 } + +emsOutputRelayConfigEntry OBJECT-TYPE + SYNTAX EMSOutputRelayConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The output relays to configure." + INDEX { emsOutputRelayConfigOutputRelayIndex } + ::= { emsOutputRelayConfigTable 1 } + +EMSOutputRelayConfigEntry ::= + SEQUENCE { + emsOutputRelayConfigOutputRelayIndex INTEGER, + emsOutputRelayConfigOutputRelayName DisplayString, + emsOutputRelayConfigOutputRelayNormalState INTEGER + } + +emsOutputRelayConfigOutputRelayIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the output relay entry." + ::= { emsOutputRelayConfigEntry 1 } + +emsOutputRelayConfigOutputRelayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the output relay." + ::= { emsOutputRelayConfigEntry 2 } + +emsOutputRelayConfigOutputRelayNormalState OBJECT-TYPE + SYNTAX INTEGER { + normallyClosedEMS (1), + normallyOpenEMS (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this variable will return the normal state of the output relay. If + the normal state is closed, the normallyClosedEMS (1) value will be returned. + If the normal state is closed, the normallyOpenEMS (2) value will be + returned. + + Setting this variable will change the normal state of the output relay" + ::= { emsOutputRelayConfigEntry 3 } + +-- EMS OUTLET CONFIG TABLE + +emsOutletConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF EMSOutletConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of individual outlets. The number of + entries is contained in the emsStatusOutletCount OID." + ::= { emsOutletConfig 1 } + +emsOutletConfigEntry OBJECT-TYPE + SYNTAX EMSOutletConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlets to configure." + INDEX { emsOutletConfigOutletIndex } + ::= { emsOutletConfigTable 1 } + +EMSOutletConfigEntry ::= + SEQUENCE { + emsOutletConfigOutletIndex INTEGER, + emsOutletConfigOutletName DisplayString, + emsOutletConfigOutletNormalState INTEGER + } + +emsOutletConfigOutletIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { emsOutletConfigEntry 1 } + +emsOutletConfigOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the outlet." + ::= { emsOutletConfigEntry 2 } + +emsOutletConfigOutletNormalState OBJECT-TYPE + SYNTAX INTEGER { + normallyOnEMS (1), + normallyOffEMS (2) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this variable will return the normal state of the outlet. If + the normal state is on, the normallyOnEMS (1) value will be returned. + If the normal state is off, the normallyOffEMS (2) value will be + returned. + + Setting this variable will change the normal state of the outlet" + ::= { emsOutletConfigEntry 3 } + +-- EMS SENSOR CONFIG TABLE + +emsSensorConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF EMSSensorConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of individual sensors. The number of + entries is contained in the emsStatusSensorCount OID." + ::= { emsSensorConfig 1 } + +emsSensorConfigEntry OBJECT-TYPE + SYNTAX EMSSensorConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The sensors to configure." + INDEX { emsSensorConfigSensorIndex } + ::= { emsSensorConfigTable 1 } + +EMSSensorConfigEntry ::= + SEQUENCE { + emsSensorConfigSensorIndex INTEGER, + emsSensorConfigSensorSystemName DisplayString, + emsSensorConfigSensorUserName DisplayString, + emsSensorConfigSensorNormalState INTEGER, + emsSensorConfigSensorAlarmDelay INTEGER + } + +emsSensorConfigSensorIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the sensor entry." + ::= { emsSensorConfigEntry 1 } + +emsSensorConfigSensorSystemName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system name of the sensor. This describes the hardware system + intent of this sensor." + ::= { emsSensorConfigEntry 2 } + +emsSensorConfigSensorUserName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the sensor as given by the system user." + ::= { emsSensorConfigEntry 3 } + +emsSensorConfigSensorNormalState OBJECT-TYPE + SYNTAX INTEGER { + normallyClosedEMS (1), + normallyOpenEMS (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Getting this variable will return the normal state of the sensor. If + the normal state is closed, the normallyClosedEMS (1) value will be returned. + If the normal state is closed, the normallyOpenEMS (2) value will be + returned. + + Setting this variable will change the normal state of the sensor. Note: + Only the AUX sensor in the EMS has a configurable Normal State" + ::= { emsSensorConfigEntry 4 } + +emsSensorConfigSensorAlarmDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The delay (in seconds) after a sensor detects an alarm condition before the + condition is reported." + ::= { emsSensorConfigEntry 5 } + +-- EMS STATUS +--- EMS MASTER status + +emsStatusEMSName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + device. " + ::= { emsStatus 1 } + +emsStatusCommStatus OBJECT-TYPE + SYNTAX INTEGER { + noComm(1), + comm(2), + commLost(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The communication status between the agent + and the device. + + noComm(1), Communication has never been established. + comm(2), Communication has been established. + commLost(3), Communication was established, but was lost." + ::= { emsStatus 2 } + +emsStatusProbeCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of T/H probes (both local and remote) that + is supported by this device." + ::= { emsStatus 3 } + +emsStatusInputContactCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of Input Contacts that + is supported by this device." + ::= { emsStatus 4 } + +emsStatusOutputRelayCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of Output Relays that + is supported by this device." + ::= { emsStatus 5 } + +emsStatusOutletCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of AC Outlets that + is supported by this device." + ::= { emsStatus 6 } + +emsStatusSensorCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of Sensors that + is supported by this device." + ::= { emsStatus 7 } + +emsStatusAlinkAruDeviceCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of remote Aru's supported by this device." + ::= { emsStatus 8 } + +emsStatusAlinkProbeDeviceCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of remote T/H probes supported by this device." + ::= { emsStatus 9 } + +emsStatusAlarmDeviceCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of alarm devices supported by this device." + ::= { emsStatus 10 } + +emsStatusSysTempUnits OBJECT-TYPE + SYNTAX INTEGER { + celsius(1), + fahrenheit(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature scale used to display the temperature + in the system, Celsius(1) or Fahrenheit(2). + This setting is based on the system preferences + configuration in the agent." + ::= { emsStatus 11 } + +emsStatusCheckLogLight OBJECT-TYPE + SYNTAX INTEGER { + lightOff (1), + lightOn (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the check-log light on the device. + For the EMU2, this will always indicate lightOff(1). + + lightOff (1) indicates the light is off (no new log entries). + lightOn (2) indicates the light is on (new log entries present)." + + ::= { emsStatus 12 } + +emsStatusHardwareStatus OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the EMS hardware. This integer should be interpreted + as a bit map, with each bit representing the presence or absence of + a specific hardware error condition. + + 0 indicates there are no error conditions detected in the EMS hardware. + 1 indicates a Current Limit error condition related to the Alink port. + 2 indicates incorrect hardware is plugged into an EMS port. + 3 indicates that both of these error conditions are present." + + ::= { emsStatus 13 } + +-- EMS PROBE STATUS TABLE + +emsProbeStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF EMSProbeStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for access of individual probes. The number of + entries is contained in the emsStatusProbeCount OID." + ::= { emsProbeStatus 1 } + +emsProbeStatusEntry OBJECT-TYPE + SYNTAX EMSProbeStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The probes to access." + INDEX { emsProbeStatusProbeIndex } + ::= { emsProbeStatusTable 1 } + +EMSProbeStatusEntry ::= + SEQUENCE { + emsProbeStatusProbeIndex INTEGER, + emsProbeStatusProbeName DisplayString, + emsProbeStatusProbeTemperature INTEGER, + emsProbeStatusProbeHighTempThresh INTEGER, + emsProbeStatusProbeLowTempThresh INTEGER, + emsProbeStatusProbeHumidity INTEGER, + emsProbeStatusProbeHighHumidityThresh INTEGER, + emsProbeStatusProbeLowHumidityThresh INTEGER, + emsProbeStatusProbeSerialNumber DisplayString, + emsProbeStatusProbeCommStatus INTEGER, + emsProbeStatusProbeAlarmStatus INTEGER, + emsProbeStatusProbeMaxTempThresh INTEGER, + emsProbeStatusProbeMinTempThresh INTEGER, + emsProbeStatusProbeMaxHumidityThresh INTEGER, + emsProbeStatusProbeMinHumidityThresh INTEGER + } + +emsProbeStatusProbeIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the probe entry." + ::= { emsProbeStatusEntry 1 } + +emsProbeStatusProbeName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the probe." + ::= { emsProbeStatusEntry 2 } + +emsProbeStatusProbeTemperature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Probe temperature reading. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the emsStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { emsProbeStatusEntry 3 } + +emsProbeStatusProbeHighTempThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Probe high temperature threshold. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the emsStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { emsProbeStatusEntry 4 } + +emsProbeStatusProbeLowTempThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Probe low temperature threshold. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the emsStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { emsProbeStatusEntry 5 } + +emsProbeStatusProbeHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Probe humidity reading. + + Values are represented in whole number percentage." + ::= { emsProbeStatusEntry 6 } + +emsProbeStatusProbeHighHumidityThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Probe high humidity threshold. + + Values are represented in whole number percentage." + ::= { emsProbeStatusEntry 7 } + +emsProbeStatusProbeLowHumidityThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Probe low humidity threshold. + + Values are represented in whole number percentage." + ::= { emsProbeStatusEntry 8 } + +emsProbeStatusProbeSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A label indicating the type (Local[L] or Remote[R]) and Number + of the probe. For example, the first local probe would be L1 and + the third remote probe would be R3." + ::= { emsProbeStatusEntry 9 } + +emsProbeStatusProbeCommStatus OBJECT-TYPE + SYNTAX INTEGER { + commsNeverDiscovered(1), + commsEstablished(2), + commsLost(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + " The state of communications to the probe. + commNeverDiscovered(1) indicates there has never been communications with this device. + commsEstablished(2) indicates communication is normal and active with this device. + commsLost(3) indicates communication had been established, but is no longer." + ::= { emsProbeStatusEntry 10 } + +emsProbeStatusProbeAlarmStatus OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The alarm status of the probe. This integer should be interpreted + as a bit map, with each bit representing the presence or absence of + the specific alarm conditions listed below. The bit will be '1' if + the condition is present, and '0' if the condition is not present. + + Bit Hex. Value Description + 1 0x0001 Maximum temperature exceeded. + 2 0x0002 High temperature exceeded. + 3 0x0004 Low temperature exceeded. + 4 0x0008 Minimum temperature exceeded. + 5 0x0010 Short-term increasing temperature rate exceeded. + 6 0x0020 Short-term decreasing temperature rate exceeded. + 7 0x0040 Long-term increasing temperature rate exceeded. + 8 0x0080 Long-term decreasing temperature rate exceeded. + 9 0x0100 Maximum humidity exceeded. + 10 0x0200 High humidity exceeded. + 11 0x0400 Low humidity exceeded. + 12 0x0800 Minimum humidity exceeded." + ::= { emsProbeStatusEntry 11 } + +emsProbeStatusProbeMaxTempThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Probe maximum temperature threshold. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the emsStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { emsProbeStatusEntry 12 } + +emsProbeStatusProbeMinTempThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Probe minimum temperature threshold. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the emsStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { emsProbeStatusEntry 13 } + +emsProbeStatusProbeMaxHumidityThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Probe maximum humidity threshold. + + Values are represented in whole number percentage." + ::= { emsProbeStatusEntry 14 } + +emsProbeStatusProbeMinHumidityThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Probe minimum humidity threshold. + + Values are represented in whole number percentage." + ::= { emsProbeStatusEntry 15 } + + +-- EMS INPUT CONTACT STATUS TABLE + +emsInputContactStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF EMSInputContactStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for access of individual input contacts. The number of + entries is contained in the emsStatusInputContactCount OID." + ::= { emsInputContactStatus 1 } + +emsInputContactStatusEntry OBJECT-TYPE + SYNTAX EMSInputContactStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The input contacts to access." + INDEX { emsInputContactStatusInputContactIndex } + ::= { emsInputContactStatusTable 1 } + +EMSInputContactStatusEntry ::= + SEQUENCE { + emsInputContactStatusInputContactIndex INTEGER, + emsInputContactStatusInputContactName DisplayString, + emsInputContactStatusInputContactState INTEGER, + emsInputContactStatusInputContactNormalState INTEGER + } + +emsInputContactStatusInputContactIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the input contact entry." + ::= { emsInputContactStatusEntry 1 } + +emsInputContactStatusInputContactName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the input contact." + ::= { emsInputContactStatusEntry 2 } + +emsInputContactStatusInputContactState OBJECT-TYPE + SYNTAX INTEGER { + contactClosedEMS (1), + contactOpenEMS (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the state of the input contact. If + the input contact is closed, the contactClosedEMS (1) value will be returned. + If the input contact state is open, the contactOpenEMS (2) value will be + returned. " + + ::= { emsInputContactStatusEntry 3 } + +emsInputContactStatusInputContactNormalState OBJECT-TYPE + SYNTAX INTEGER { + normallyClosedEMS (1), + normallyOpenEMS (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the normal state of the input contact. If + the normal state is closed, the normallyClosedEMS (1) value will be returned. + If the normal state is open, the normallyOpenEMS (2) value will be + returned. " + + ::= { emsInputContactStatusEntry 4 } + + +-- EMS OUTPUT RELAY STATUS TABLE + +emsOutputRelayStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF EMSOutputRelayStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for access of individual output relays. The number of + entries is contained in the emsStatusOutputRelayCount OID." + ::= { emsOutputRelayStatus 1 } + +emsOutputRelayStatusEntry OBJECT-TYPE + SYNTAX EMSOutputRelayStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The output relays to access." + INDEX { emsOutputRelayStatusOutputRelayIndex } + ::= { emsOutputRelayStatusTable 1 } + +EMSOutputRelayStatusEntry ::= + SEQUENCE { + emsOutputRelayStatusOutputRelayIndex INTEGER, + emsOutputRelayStatusOutputRelayName DisplayString, + emsOutputRelayStatusOutputRelayState INTEGER, + emsOutputRelayStatusOutputRelayNormalState INTEGER + } + +emsOutputRelayStatusOutputRelayIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the output relay entry." + ::= { emsOutputRelayStatusEntry 1 } + +emsOutputRelayStatusOutputRelayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the output relay." + ::= { emsOutputRelayStatusEntry 2 } + +emsOutputRelayStatusOutputRelayState OBJECT-TYPE + SYNTAX INTEGER { + relayClosedEMS (1), + relayOpenEMS (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the state of the output relay. If + the output relay is closed, the relayClosedEMS (1) value will be returned. + If the output relay is open, the relayOpenEMS (2) value will be + returned. " + + ::= { emsOutputRelayStatusEntry 3 } + +emsOutputRelayStatusOutputRelayNormalState OBJECT-TYPE + SYNTAX INTEGER { + normallyClosedEMS (1), + normallyOpenEMS (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the normal state of the output relay. If + the normal state is closed, the normallyClosedEMS (1) value will be returned. + If the normal state is open, the normallyOpenEMS (2) value will be + returned. " + + ::= { emsOutputRelayStatusEntry 4 } + +-- EMS OUTLET STATUS TABLE + +emsOutletStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF EMSOutletStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for access of individual outlets. The number of + entries is contained in the emsStatusOutletCount OID." + ::= { emsOutletStatus 1 } + +emsOutletStatusEntry OBJECT-TYPE + SYNTAX EMSOutletStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The outlets to access." + INDEX { emsOutletStatusOutletIndex } + ::= { emsOutletStatusTable 1 } + +EMSOutletStatusEntry ::= + SEQUENCE { + emsOutletStatusOutletIndex INTEGER, + emsOutletStatusOutletName DisplayString, + emsOutletStatusOutletState INTEGER, + emsOutletStatusOutletNormalState INTEGER + } + +emsOutletStatusOutletIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the outlet entry." + ::= { emsOutletStatusEntry 1 } + +emsOutletStatusOutletName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the outlet." + ::= { emsOutletStatusEntry 2 } + +emsOutletStatusOutletState OBJECT-TYPE + SYNTAX INTEGER { + outletOnEMS (1), + outletOffEMS (2) + } + + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the state of the outlet. If + the outlet is on, the outletOnEMS (1) value will be returned. + If the outlet is off, the outletOffEMS (2) value will be + returned. " + + ::= { emsOutletStatusEntry 3 } + +emsOutletStatusOutletNormalState OBJECT-TYPE + SYNTAX INTEGER { + normallyOnEMS (1), + normallyOffEMS (2) + } + + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the normal state of the outlet. If + the normal state is on, the normallyOnEMS (1) value will be returned. + If the normal state is off, the normallyOffEMS (2) value will be + returned. " + + ::= { emsOutletStatusEntry 4 } + +-- EMS ALARM DEVICE STATUS TABLE + +emsAlarmDeviceStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF EMSAlarmDeviceStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for access of individual alarm devices. The number of + entries is contained in the emsStatusAlarmDeviceCount OID." + ::= { emsAlarmDeviceStatus 1 } + +emsAlarmDeviceStatusEntry OBJECT-TYPE + SYNTAX EMSAlarmDeviceStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The alarm devices to access." + INDEX { emsAlarmDeviceStatusDeviceIndex } + ::= { emsAlarmDeviceStatusTable 1 } + +EMSAlarmDeviceStatusEntry ::= + SEQUENCE { + emsAlarmDeviceStatusDeviceIndex INTEGER, + emsAlarmDeviceStatusDeviceName DisplayString, + emsAlarmDeviceStatusDeviceState INTEGER + } + +emsAlarmDeviceStatusDeviceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the alarm device entry." + ::= { emsAlarmDeviceStatusEntry 1 } + +emsAlarmDeviceStatusDeviceName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the alarm device. + This OID is provided for informational purposes only." + ::= { emsAlarmDeviceStatusEntry 2 } + +emsAlarmDeviceStatusDeviceState OBJECT-TYPE + SYNTAX INTEGER { + alarmDeviceOnEMS (1), + alarmDeviceOffEMS (2), + alarmDeviceNotInstalledEMS (3) + } + + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the device state. If + the device is active, the alarmDeviceOnEMS (1) value will be returned. + If the device is inactive, the alarmDeviceOffEMS (2) value will be + returned. If the device is not installed, the + alarmDeviceNotInstalledEMS (3) value will be returned." + + ::= { emsAlarmDeviceStatusEntry 3 } + + +-- EMS SENSOR STATUS TABLE + +emsSensorStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF EMSSensorStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for access of individual sensors. The number of + entries is contained in the emsStatusSensorCount OID." + ::= { emsSensorStatus 1 } + +emsSensorStatusEntry OBJECT-TYPE + SYNTAX EMSSensorStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The sensors to access." + INDEX { emsSensorStatusSensorIndex } + ::= { emsSensorStatusTable 1 } + +EMSSensorStatusEntry ::= + SEQUENCE { + emsSensorStatusSensorIndex INTEGER, + emsSensorStatusSensorSystemName DisplayString, + emsSensorStatusSensorName DisplayString, + emsSensorStatusSensorState INTEGER, + emsSensorStatusSensorNormalState INTEGER, + emsSensorStatusSensorAlarmDelay INTEGER + } + +emsSensorStatusSensorIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the sensor entry." + ::= { emsSensorStatusEntry 1 } + +emsSensorStatusSensorSystemName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system name of the sensor. This describes the hardware system + intent of this sensor." + ::= { emsSensorStatusEntry 2 } + +emsSensorStatusSensorName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the sensor as given by the system user." + ::= { emsSensorStatusEntry 3 } + +emsSensorStatusSensorState OBJECT-TYPE + SYNTAX INTEGER { + sensorFaultedEMS (1), + sensorOKEMS (2), + sensorNotInstalledEMS (3) + } + + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the sensor state. If the sensor is faulted, + the sensorFaultedEMS (1) value will be returned. + If the sensor is not faulted, the sensorOKEMS (2) value will be + returned. If the sensor is not installed, the sensorNotInstalledEMS (3) + value will be returned." + ::= { emsSensorStatusEntry 4 } + +emsSensorStatusSensorNormalState OBJECT-TYPE + SYNTAX INTEGER { + normallyClosedEMS (1), + normallyOpenEMS (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Getting this variable will return the normal state of the sensor. If + the normal state is closed, the normallyClosedEMS (1) value will be returned. + If the normal state is closed, the normallyOpenEMS (2) value will be + returned." + ::= { emsSensorStatusEntry 5 } + +emsSensorStatusSensorAlarmDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The delay (in seconds) after a sensor detects an alarm condition before the + condition is reported." + ::= { emsSensorStatusEntry 6 } + + + +-- airFM AIR CONDITIONER IDENT + +airFMIdentName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the device." + ::= { airFMIdent 1 } + +airFMIdentTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMIdentTable. " + ::= { airFMIdent 2 } + +airFMIdentTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMIdentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting identification information + from each module in the system. " + ::= { airFMIdent 3 } + +airFMIdentEntry OBJECT-TYPE + SYNTAX AirFMIdentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The module to get information from." + INDEX { airFMIdentModuleIndex } + ::= { airFMIdentTable 1 } + +AirFMIdentEntry ::= + SEQUENCE { + airFMIdentModuleIndex INTEGER, + airFMIdentModuleModelNumber DisplayString, + airFMIdentModuleDateOfMfg DisplayString, + airFMIdentModuleSerialNumber DisplayString, + airFMIdentModuleFirmwareRev DisplayString, + airFMIdentModuleHardwareRev DisplayString + } + +airFMIdentModuleIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the module information." + ::= { airFMIdentEntry 1 } + +airFMIdentModuleModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + model number. " + ::= { airFMIdentEntry 2 } + +airFMIdentModuleDateOfMfg OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + manufacture date. " + ::= { airFMIdentEntry 3 } + +airFMIdentModuleSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit serial number. " + ::= { airFMIdentEntry 4 } + +airFMIdentModuleFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + firmware revision. " + ::= { airFMIdentEntry 5 } + +airFMIdentModuleHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + hardware revision. " + ::= { airFMIdentEntry 6 } + +airFMIdentLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the + location of the device. " + ::= { airFMIdent 4 } + +airFMIdentContact OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the + person to contact regarding the device. " + ::= { airFMIdent 5 } + + +-- airFM AIR CONDITIONER STATUS + +airFMStatusSystemOn OBJECT-TYPE + SYNTAX INTEGER { + statusOn (1), + statusOff (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The operating state of the system. + This OID has been deprecated in favor of + airFMGroupSysStatus." + ::= { airFMStatus 1 } + +airFMStatusSystemAverageRetTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system average return air + temperature in tenths of degrees Celsius. + This OID has been deprecated in favor of + airFMSysAvgReturnTempC." + ::= { airFMStatus 2 } + +airFMStatusSystemAverageRetTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system average return air + temperature in tenths of degrees Fahrenheit. + This OID has been deprecated in favor of + airFMSysAvgReturnTempF." + ::= { airFMStatus 3 } + +airFMStatusSystemAverageRetHum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system average return air + humidity in tenths of percent RH. + This OID has been deprecated in favor of + airFMSysAvgReturnHum." + ::= { airFMStatus 4 } + +airFMStatusSystemActionTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system action air + temperature in tenths of degrees Celsius. + This OID has been deprecated in favor of + airFMSysCtrlTempC." + ::= { airFMStatus 5 } + +airFMStatusSystemActionTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system action air + temperature in tenths of degrees Fahrenheit. + This OID has been deprecated in favor of + airFMSysCtrlTempF." + ::= { airFMStatus 6 } + +airFMStatusSystemActionHum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system action air humidity in tenths of percent RH. + This OID has been deprecated in favor of + airFMSysCtrlHum." + ::= { airFMStatus 7 } + +airFMStatusSystemRemoteHighTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system remote high air + temperature in tenths of degrees Celsius. + This OID has been deprecated in favor of + airFMSysMaxRemoteTempC." + ::= { airFMStatus 8 } + +airFMStatusSystemRemoteHighTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system remote high air + temperature in tenths of degrees Fahrenheit. + This OID has been deprecated in favor of + airFMSysMaxRemoteTempF." + ::= { airFMStatus 9 } + +airFMStatusSystemRemoteAvgTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system remote average air + temperature in tenths of degrees Celsius. + This OID has been deprecated in favor of + airFMSysAvgRemoteTempC." + ::= { airFMStatus 10 } + +airFMStatusSystemRemoteAvgTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system remote average air + temperature in tenths of degrees Fahrenheit. + This OID has been deprecated in favor of + airFMSysAvgRemoteTempF." + ::= { airFMStatus 11 } + +airFMStatusSystemRemoteAvgHum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system remote average air + humidity in tenths of percent RH. + This OID has been deprecated in favor of + airFMSysAvgRemoteHum." + ::= { airFMStatus 12 } + +airFMStatusSystemRemoteLowTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system remote low air + temperature in tenths of degrees Celsius. + This OID has been deprecated in favor of + airFMSysMinRemoteTempC." + ::= { airFMStatus 13 } + +airFMStatusSystemRemoteLowTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system remote low air + temperature in tenths of degrees Fahrenheit. + This OID has been deprecated in favor of + airFMSysMinRemoteTempF." + + ::= { airFMStatus 14 } + +airFMStatusSystemCoolingEnabled OBJECT-TYPE + SYNTAX INTEGER { + enabledYes (1), + enabledNo (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the system cooling + function enable. + This OID has been deprecated in favor of + airFMSysCoolState." + ::= { airFMStatus 15 } + +airFMStatusSystemReheatingEnabled OBJECT-TYPE + SYNTAX INTEGER { + enabledYes (1), + enabledNo (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the system reheating + function enable. + This OID has been deprecated in favor of + airFMSysReheatState." + ::= { airFMStatus 16 } + +airFMStatusSystemHumidifyEnabled OBJECT-TYPE + SYNTAX INTEGER { + enabledYes (1), + enabledNo (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the system humidify + function enable. + This OID has been deprecated in favor of + airFMSysHumState." + ::= { airFMStatus 17 } + +airFMStatusSystemDehumidifyEnabled OBJECT-TYPE + SYNTAX INTEGER { + enabledYes (1), + enabledNo (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the system dehumidify + function enable. + This OID has been deprecated in favor of + airFMSysDehumState." + ::= { airFMStatus 18 } + +airFMStatusModuleTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMStatusModuleTable." + ::= { airFMStatus 19 } + +airFMStatusModuleTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMStatusModuleEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each module + in the system." + ::= { airFMStatus 20 } + +airFMStatusModuleEntry OBJECT-TYPE + SYNTAX AirFMStatusModuleEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The module to get status from." + INDEX { airFMStatusModuleIndex } + ::= { airFMStatusModuleTable 1 } + +AirFMStatusModuleEntry ::= + SEQUENCE { + airFMStatusModuleIndex INTEGER, + airFMStatusModuleOutputCapacity INTEGER, + airFMStatusModuleSupplyTempC INTEGER, + airFMStatusModuleSupplyTempF INTEGER, + airFMStatusModuleSupplyHum INTEGER, + airFMStatusModuleReturnTempC INTEGER, + airFMStatusModuleReturnTempF INTEGER, + airFMStatusModuleReturnHum INTEGER + } + +airFMStatusModuleIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the module information." + ::= { airFMStatusModuleEntry 1 } + +airFMStatusModuleOutputCapacity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The module output capacity in kilowatts. + This OID has been deprecated in favor of + airFMModOutputCapacity." + ::= { airFMStatusModuleEntry 2 } + +airFMStatusModuleSupplyTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The module supply air temperature in + tenths of degrees Celsius. + This OID has been deprecated in favor of + airFMModSupplyTempC." + ::= { airFMStatusModuleEntry 3 } + +airFMStatusModuleSupplyTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The module supply air temperature in + tenths of degrees Fahrenheit. + This OID has been deprecated in favor of + airFMModSupplyTempF." + ::= { airFMStatusModuleEntry 4 } + +airFMStatusModuleSupplyHum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The module supply air humidity in tenths of percent RH. + This OID has been deprecated in favor of + airFMModSupplyHum." + ::= { airFMStatusModuleEntry 5 } + +airFMStatusModuleReturnTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The module return air temperature in + tenths of degrees Celsius. + This OID has been deprecated in favor of + airFMModReturnTempC." + ::= { airFMStatusModuleEntry 6 } + +airFMStatusModuleReturnTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The module return air temperature in + tenths of degrees Fahrenheit. + This OID has been deprecated in favor of + airFMModReturnTempF." + ::= { airFMStatusModuleEntry 7 } + +airFMStatusModuleReturnHum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The module return air humidity in tenths of percent RH. + This OID has been deprecated in favor of + airFMModReturnHum." + ::= { airFMStatusModuleEntry 8 } + +-- airFM AIR CONDITIONER GROUP DATA + +airFMGroupSysStatus OBJECT-TYPE + SYNTAX INTEGER { + statusOnLine (1), + statusIdle (2), + statusLoadShare (3), + statusOffLine (4), + statusFailed (5), + statusDisabled (6), + statusUndefined (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of this system within the group." + ::= { airFMGroup 1 } + +airFMGroupSysRuntime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of hours the system has been running." + ::= { airFMGroup 2 } + +airFMGroupSysRole OBJECT-TYPE + SYNTAX INTEGER { + rolePrimary (1), + roleBackup (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The role of this system within the group." + ::= { airFMGroup 3 } + +-- airFM Group System Roles +airFMGroupSysRolesTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMGroupSysRolesTable. " + ::= { airFMGroupSysRoles 1 } + +airFMGroupSysRolesTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMGroupSysRolesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each system + in the group. " + ::= { airFMGroupSysRoles 2 } + +airFMGroupSysRolesEntry OBJECT-TYPE + SYNTAX AirFMGroupSysRolesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The system to get status from." + INDEX { airFMGroupSysIndex } + ::= { airFMGroupSysRolesTable 1 } + +AirFMGroupSysRolesEntry ::= + SEQUENCE { + airFMGroupSysIndex INTEGER, + airFMGroupSysRoleStatus INTEGER, + airFMGroupSysPresentRole INTEGER, + airFMGroupSysManualRoleSetting INTEGER, + airFMGroupSysRunHours INTEGER, + airFMGroupSysComm INTEGER, + airFMGroupSysIPAddress IpAddress + } + +airFMGroupSysIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the system information." + ::= { airFMGroupSysRolesEntry 1 } + +airFMGroupSysRoleStatus OBJECT-TYPE + SYNTAX INTEGER { + reserved1 (1), + reserved2 (2), + onLine (3), + idle (4), + loadShare (5), + failed (6), + offLine (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The present mode of the System." + ::= { airFMGroupSysRolesEntry 2 } + +airFMGroupSysPresentRole OBJECT-TYPE + SYNTAX INTEGER { + primary (1), + backup (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The present role of the System in a Group." + ::= { airFMGroupSysRolesEntry 3 } + +airFMGroupSysManualRoleSetting OBJECT-TYPE + SYNTAX INTEGER { + primary (1), + backup (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The manual role setting of the System in a Group. + Only applies if Role Assignment Method is set + to static (Manually Assigned Roles)." + ::= { airFMGroupSysRolesEntry 4 } + +airFMGroupSysRunHours OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of hours the System has been + contributing to environmental control." + ::= { airFMGroupSysRolesEntry 5 } + +airFMGroupSysComm OBJECT-TYPE + SYNTAX INTEGER { + commLost (1), + commEstablished (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether a system is communicating with the + other Systems in the Group." + ::= { airFMGroupSysRolesEntry 6 } + +airFMGroupSysIPAddress OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The IP Address of the System." + ::= { airFMGroupSysRolesEntry 7 } + +airFMGroupSysRoleAssignment OBJECT-TYPE + SYNTAX INTEGER { + staticManual (1), + dynamicAutomatic (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The method used to assign roles (i.e. Primary, Backup) + to the Systems in a Group. + + staticManual: Manually assign Primary or Backup to + regulate run hours across the Group. + dynamicAutomatic: User indicates the number of Systems + that will be assigned a primary role in this Group." + ::= { airFMGroupSysRoles 3 } + +airFMGroupAutoRoleNumPrimary OBJECT-TYPE + SYNTAX INTEGER { + one (1), + two (2), + three (3), + four (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of Systems assigned the 'primary' role in + this Group. Only applies if Role Assignment Method + is set to dynamic (Automatic Run Hour Balancing)." + ::= { airFMGroupSysRoles 4 } + +-- airFM Group Config +airFMGroupCfgName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the group name." + ::= { airFMGroupCfg 1 } + +airFMGroupCfgNumSystems OBJECT-TYPE + SYNTAX INTEGER { + one (1), + two (2), + three (3), + four (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of Systems in this Group." + ::= { airFMGroupCfg 2 } + +airFMGroupCfgIdleBlower OBJECT-TYPE + SYNTAX INTEGER { + off (1), + minimumSpeed (2), + normalSpeed (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Blower behavior for backup Systems and Systems that + have entered a failure mode." + ::= { airFMGroupCfg 3 } + +airFMGroupCfgShutdownSmoke OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "If enabled, all Systems in the Group will shut down + if smoke is detected." + ::= { airFMGroupCfg 4 } + +airFMGroupCfgShutdownFire OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "If enabled, all Systems in the Group will shut down + if fire is detected." + ::= { airFMGroupCfg 5 } + +airFMGroupCfgFailoverCommLoss OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Failover on Comm Loss enables an available backup + System to run in place of a System that has lost + communication with the Group." + ::= { airFMGroupCfg 6 } + +airFMGroupCfgDmdFightStatus OBJECT-TYPE + SYNTAX INTEGER { + off (1), + on (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Demand Fighting and Setpoint Sharing are + automatically enabled when a System is responding to + a Load Sharing Request." + ::= { airFMGroupCfg 7 } + +airFMGroupCfgDmdFightSetting OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Demand Fighting prevents a System from engaging + reheat in a Group where any System is cooling." + ::= { airFMGroupCfg 8 } + +airFMGroupCfgSetpointShareStatus OBJECT-TYPE + SYNTAX INTEGER { + off (1), + on (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Demand Fighting and Setpoint Sharing are + automatically enabled when a System is responding to + Load Sharing Request." + ::= { airFMGroupCfg 9 } + +airFMGroupCfgSetpointShareSetting OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "All Systems in the Group use the same setpoints." + ::= { airFMGroupCfg 10 } + +airFMGroupCfgResetFieldServiceDefaults OBJECT-TYPE + SYNTAX INTEGER { + noOperation (1), + reset (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset(2) will reset all Group + parameters, which can only be edited by a field + service engineer, to their factory default values. + + Getting this OID will do nothing and return the + noOperation(1) value." + ::= { airFMGroupCfg 11 } + +-- airFM Group Load Sharing +airFMGroupLoadShareCoolRequests OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Systems that are cooling may request assistance from + other Systems in the Group." + ::= { airFMGroupLoadShare 1 } + +airFMGroupLoadShareCoolThreshC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Temperature threshold at which a System will generate + a load sharing request for cooling. Measured in + tenths of degrees Celsius." + ::= { airFMGroupLoadShare 2 } + +airFMGroupLoadShareCoolThreshF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Temperature threshold at which a System will generate + a load sharing request for cooling. Measured in + tenths of degrees Fahrenheit." + ::= { airFMGroupLoadShare 3 } + +airFMGroupLoadShareReheatRequests OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Systems that are reheating may request assistance + from other Systems in the Group." + ::= { airFMGroupLoadShare 4 } + +airFMGroupLoadShareReheatThreshC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Temperature threshold at which a System will generate + a load sharing request for reheating. Measured in + tenths of degrees Celsius." + ::= { airFMGroupLoadShare 5 } + +airFMGroupLoadShareReheatThreshF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Temperature threshold at which a System will generate + a load sharing request for reheating. Measured in + tenths of degrees Fahrenheit." + ::= { airFMGroupLoadShare 6 } + +airFMGroupLoadShareHumRequests OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Systems that are humidifying may request humidification + assistance from other Systems in the Group." + ::= { airFMGroupLoadShare 7 } + +airFMGroupLoadShareHumThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Humidity threshold at which a System will generate a + load sharing request for humidification. Measured in + tenths of percent relative humidity." + ::= { airFMGroupLoadShare 8 } + +airFMGroupLoadShareDehumRequests OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Systems that are dehumidifying may request assistance + from other Systems in the Group." + ::= { airFMGroupLoadShare 9 } + +airFMGroupLoadShareDehumThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Humidity threshold at which a System will generate a + load sharing request for dehumidification. Measured in + tenths of percent relative humidity." + ::= { airFMGroupLoadShare 10 } + +-- airFM Group System Failover Events +airFMGroupFailoverSysAnyMinorAlarm OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if any minor system alarm is active. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverSys 1 } + +airFMGroupFailoverSysAnyMajorAlarm OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if any major system alarm is active. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverSys 2 } + +airFMGroupFailoverSysHighEnvTemp OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if the high environmental temperature + alarm is active. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverSys 3 } + +airFMGroupFailoverSysLowEnvTemp OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if the low environmental temperature + alarm is active. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverSys 4 } + +airFMGroupFailoverSysHighEnvHum OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if the high environmental humidity + alarm is active. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverSys 5 } + +airFMGroupFailoverSysLowEnvHum OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if the low environmental humidity + alarm is active. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverSys 6 } + +airFMGroupFailoverSysFireAlarm OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if the fire alarm is active. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverSys 7 } + +airFMGroupFailoverSysSmokeAlarm OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if the smoke alarm is active. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverSys 8 } + +airFMGroupFailoverSysCommLost OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if the system has lost comm. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverSys 9 } + +airFMGroupFailoverSysSupplySensorFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if the supply sensor has failed. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverSys 10 } + +airFMGroupFailoverSysReturnSensorFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if the return sensor has failed. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverSys 11 } + +airFMGroupFailoverSysPrimarySensorFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if the primary sensor has failed. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverSys 12 } + +airFMGroupFailoverSysSecondarySensorFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if the secondary sensor has failed. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverSys 13 } + +airFMGroupFailoverSysNoSensorsAvailable OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if no sensors are available. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverSys 14 } + +-- airFM Group Module Failover Events +airFMGroupFailoverModMaintRequired OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if maintenance is required on a + module. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverMod 1 } + +airFMGroupFailoverModCoolFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if cooling has failed on a module. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverMod 2 } + + +airFMGroupFailoverModHumFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if the humidifier has failed on a + module. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverMod 3 } + +airFMGroupFailoverModBlwrCntrl1Fail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if blower controller 1 has failed on + a module. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverMod 4 } + +airFMGroupFailoverModBlwrCntrl2Fail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if blower controller 2 has failed on + a module. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverMod 5 } + +airFMGroupFailoverModHighFilterDP OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if a high filter differential + pressure is present on a module. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverMod 6 } + +airFMGroupFailoverModHighSupplyTemp OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if a high supply temperature is + active on a module. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverMod 7 } + +airFMGroupFailoverModLowSupplyTemp OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if a low supply temperature is active + on a module. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverMod 8 } + +airFMGroupFailoverModLossOrLowAirFlow OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if there is a loss of air flow or low + air flow on a module. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverMod 9 } + +airFMGroupFailoverModHumReplaceCylinder OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if a humidifier needs its cylinder + replaced on a module. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverMod 10 } + +airFMGroupFailoverModAirBlockInterlockOpen OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if the air block interlock is open + on a module. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverMod 11 } + +airFMGroupFailoverModWaterDetected OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if water is detected by a module. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverMod 12 } + +airFMGroupFailoverModCondensatePumpFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disable (2), + enable (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enabling this OID will cause the system to enter + a failure state if the condensate pump has failed in + a module. + Once in the failure state, environmental control + ceases for the system, and the blowers enter the + Idle Blower Operation mode. + A value of notApplicable indicates that this alarm + does not apply to this device due to its configuration." + ::= { airFMGroupFailoverMod 13 } + +-- airFM System Status + +airFMSysNumber OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + one (2), + two (3), + three (4), + four (5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of the system within the group. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 1 } + +airFMSysPresentStatus OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + reserved1 (2), + reserved2 (3), + onLine (4), + idle (5), + loadShare (6), + failed (7), + offLine (8) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The present mode of the System. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 2 } + +airFMSysPresentRole OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + primary (2), + backup (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The present role of the System in the Group. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 3 } + +airFMSysRunHours OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of hours the System has been + contributing to environmental control. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 4 } + +airFMSysCoilFluidTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the coolant at the fluid coil + inlet. Measured in degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 5 } + +airFMSysCoilFluidTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the coolant at the fluid coil + inlet. Measured in degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 6 } + +airFMSysHotWaterTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hot water temperature. Measured in degrees + Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 7 } + +airFMSysHotWaterTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hot water temperature. Measured in degrees + Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 8 } + +airFMSysAvgReturnTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The average return temperature calculated from all + present modules. Measured in tenths of degrees + Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 9 } + +airFMSysAvgReturnTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The average return temperature calculated from all + present modules. Measured in tenths of degrees + Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 10 } + +airFMSysAvgReturnHum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The average return humidity calculated from all + present modules. Measured in tenths of percent RH. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 11 } + +airFMSysAvgRemoteTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The average temperature calculated from all + operational remote sensors. Measured in tenths of + degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 12 } + +airFMSysAvgRemoteTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The average temperature calculated from all + operational remote sensors. Measured in tenths of + degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 13 } + +airFMSysAvgRemoteHum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The average return humidity calculated from all + present modules. Measured in tenths of percent RH. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 14 } + +airFMSysMaxRemoteTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum temperature reading from all operational + remote sensors. Measured in tenths of degrees + Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 15 } + +airFMSysMaxRemoteTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum temperature reading from all operational + remote sensors. Measured in tenths of degrees + Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 16 } + +airFMSysMinRemoteTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum temperature reading from all operational + remote sensors. Measured in tenths of degrees + Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 17 } + +airFMSysMinRemoteTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum temperature reading from all operational + remote sensors. Measured in tenths of degrees + Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 18 } + +airFMSysTempCtrlMethod OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + avgReturn (2), + avgRemote (3), + maxRemote (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The method of environment temperature control + selected to regulate the temperature. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 19 } + +airFMSysActualTempCtrlMethod OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + avgReturn (2), + avgRemote (3), + maxRemote (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual method of environment temperature control + being used to regulate the temperature. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 20 } + +airFMSysHumCtrlMethod OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + avgReturnRH (2), + avgReturnDewPt (3), + avgRemoteRH (4), + avgRemoteDewPt (5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The method of environment humidity control selected + to regulate the humidity. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 21 } + +airFMSysActualHumCtrlMethod OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + avgReturnRH (2), + avgReturnDewPt (3), + avgRemoteRH (4), + avgRemoteDewPt (5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual method of environment humidity control + being used to regulate the humidity. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 22 } + +airFMSysCtrlTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system environmental control air temperature from + the sensor denoted by airFMSysActualTempCtrl. + Measured in tenths of degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 23 } + +airFMSysCtrlTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system environmental control air temperature from + the sensor denoted by airFMSysActualTempCtrl. + Measured in tenths of degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 24 } + +airFMSysCtrlHum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system environmental control air humidity from + the sensor denoted by airFMSysActualHumCtrl. + Measured in percent relative humidity. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysStatus 25 } + +-- airFM System Demands and Actuals + +airFMSysDXCoolingDmd OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The direct expansion cooling output demanded by the + System. Measured in percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDemands 1 } + +airFMSysDXDehumDmd OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The direct expansion dehumidification output demanded + by the System. Measured in percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDemands 2 } + +airFMSysDXActualCoolDehum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The direct expansion cooling or dehumidification + output measured by the System. Measured in percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDemands 3 } + +airFMSysCoilFluidCoolDmd OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The fluid coil cooling output demanded by the System. + Measured in percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDemands 4 } + +airFMSysCoilFluidDehumDmd OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The fluid coil dehumidification output demanded by + the System. Measured in percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDemands 5 } + +airFMSysCoilFluidActualCoolDehum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The fluid coil cooling or dehumidification output + measured by the System. Measured in percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDemands 6 } + +airFMSysElectricReheatDmd OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The electric reheating output demanded by the System. + Measured in percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDemands 7 } + +airFMSysActualElectricReheat OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The electric reheating output of the System. + Measured in percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDemands 8 } + +airFMSysSteamHotGasReheatDmd OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + off (2), + on (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The steam, hot water, or hot gas reheating output + demanded by the System. + A value of notApplicable indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMSysDemands 9 } + +airFMSysActualSteamHotGasReheat OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + off (2), + on (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The steam, hot water, or hot gas reheating output of + the System. + A value of notApplicable indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMSysDemands 10 } + +airFMSysSteamElectrodeHumDmd OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The steam electrode humidification output demanded by + the System. Measured in percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDemands 11 } + +airFMSysActualSteamElectrodeHum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The average steam electrode humidification output + measured for the Modules in the System. Measured in + percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDemands 12 } + +airFMSysSteamHumDmd OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + off (2), + on (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The steam humidification output demanded by the System. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDemands 13 } + +airFMSysActualSteamHum OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + off (2), + on (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The steam humidification output for the System. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDemands 14 } + +-- airFM System Physical Setup + +airFMSysNumModules OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + one (2), + two (3), + three (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Modules in this System. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysSetup 1 } + +airFMSysNumPCIOMs OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + one (2), + two (3), + three (4), + four (5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Programmable Customer Input/Output + Modules (PCIOMs) installed in the Main Module of this + System. Each PCIOM adds four input contacts and four + output relays to the System. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysSetup 2 } + +airFMSysMainsVlt OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The mains voltage for the Modules in this System. + A value of N/A indicates that this OID does not apply + to this device due to its configuration." + ::= { airFMSysSetup 3 } + +airFMSysUPSVlt OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The UPS voltage for the Modules in this System. + A value of N/A indicates that this OID does not apply + to this device due to its configuration." + ::= { airFMSysSetup 4 } + +airFMSysCoilCfg OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + dx (2), + econ (3), + multicool (4), + chilledWater (5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of cooling coils installed in the Modules in + this System: DX coil, DX and MultiCool (chilled water) + coils, DX and Economizer coils, or only a Chilled + Liquid coil. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysSetup 5 } + +airFMSysRefrigType OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + r22 (2), + r407C (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of refrigerant used by each compressor in + the system. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysSetup 6 } + +airFMSysHeatRejection OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + airCooled (2), + waterCooled (3), + glycolCooled (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The method the Modules in this System use to transfer + heat away from the refrigerant. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysSetup 7 } + +airFMSysDischAirPtrn OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + upFlow (2), + downFlow (3), + horizFlow (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The discharge air pattern for the Modules in this + System. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysSetup 8 } + +airFMSysAirFltr OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + standard (2), + highEfficiency (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of air filters (standard or high efficiency) + installed in the Modules of this System. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysSetup 9 } + +airFMSysFlowSwitch OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + none (2), + dxEcon (3), + multiCoolChillWater (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The location of the optional flow switch. + None: No flow switch is installed in this System. + DX: Coolant input to the heat exchanger (condenser). + MultiCool: Chilled water input to the MultiCool coil. + + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysSetup 10 } + +airFMSysCoilFluidVlvAct OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + none (2), + springAnalog (3), + floatingControl (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of valve actuator installed on the coil + fluid valve. The coil fluid valve controls the flow + of coolant into a fluid cooling coil, such as a + MultiCool or Economizer coil. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysSetup 11 } + +airFMSysCoilFluidVlvType OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + twoWay (2), + threeWay (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of coil fluid valve installed for the + Modules in this System. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysSetup 12 } + +airFMSysCndsrFluidVlvAct OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + none (2), + floatingControl (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of valve actuator installed on the Condenser + fluid valve. The Condenser fluid valve controls the + flow of coolant into the heat exchanger (condenser) + to regulate head pressure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysSetup 13 } + +airFMSysCndsrFluidVlvType OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + twoWay (2), + threeWay (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of Condenser fluid valve installed for the + Modules in this System. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysSetup 14 } + +airFMSysHotWaterVlvAct OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + none (2), + springAnalog (3), + floatingControl (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of valve actuator installed on the hot water + valve. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysSetup 15 } + +airFMSysNumRemoteSensors OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of remote sensors detected by the system." + ::= { airFMSysSetup 16 } + +-- airFM System Configuration + +airFMSysPrimaryControlSensor OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + return (2), + remote (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Selects whether return or remote sensors will control + the system. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysConfig 1 } + +airFMSysRemoteSensorData OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + average (2), + maximum (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Selects whether average temperature or max temperature + will be used when remote sensors are selected for + control of the system. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysConfig 2 } + +airFMSysFastStartup OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimizes the time for the cooling process to begin + after other delay constraints have been met. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysConfig 3 } + +airFMSysStartupDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the delay that begins when power is applied and + ends when the System starts. This allows you to + create a staged restart among your Systems after a + power loss. Measured in seconds. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysConfig 4 } + +airFMSysModeDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the delay between starting the blowers and + engaging the modes. It allows the sensors to read + room conditions accurately and allows the controller + to check for major alarms before engaging a mode. + Measured in seconds. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysConfig 5 } + +airFMSysCommLossShutdownDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the delay between an Expansion Module losing + communication with the Main Module and the Expansion + Module shutting down. A value of -1 will keep + the Expansion Module running after a communication + loss. Measured in hours. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysConfig 6 } + +airFMSysResetSysFailure OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset(2) will allows the system + to return from any failure condition, if the + failure(s) have cleared. + Getting this OID will do nothing and return the noOperation(1) value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysConfig 7 } + +airFMSysResetUserDflts OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset(2) will reset all system + parameters that can be edited by the user to their + factory default values. + Getting this OID will do nothing and return the noOperation(1) value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysConfig 8 } + +airFMSysResetFldSrvcDflts OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset(2) will reset all system + parameters that can only be edited by the field + service engineer to their factory default values. + Getting this OID will do nothing and return the noOperation(1) value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysConfig 9 } + +airFMSysResetRunHours OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting this OID to reset(2) will reset the system Run Hours. + Getting this OID will do nothing and return the noOperation(1) value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysConfig 10 } + +-- airFM System Cooling + +airFMSysCompMinOnTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the minimum time the compressor continues to + operate after it is started. The delay protects the + compressor from damage. Caution: Reducing this delay + shortens compressor life. Measured in seconds. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 1 } + +airFMSysCompMinOffTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the minimum time the compressor will remain off + after it ceases operation. The delay protects the + compressor from damage. Caution: Reducing this delay + shortens compressor life. Measured in seconds. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 2 } + +airFMSysCompRotPeriod OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set how often to perform compressor runtime + balancing. Measured in hours. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 3 } + +airFMSysEconIsolVlvOpenDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the delay between opening the Economizer Isolator + output relay and engaging the compressors. Measured + in seconds. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 4 } + +airFMSysEconIsolVlvCloseDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the delay between disengaging the compressor and + closing the Economizer Isolator output relay. + Measured in seconds. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 5 } + +airFMSysCndsrFluidVlvCloseDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the time the condenser valve remains open after + the compressors disengage. Measured in seconds. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 6 } + +airFMSysInterstageDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The DX interstage delay allows the first compressor's + cooling to take effect before engaging the second + compressor. This prevents the second compressor from + cycling on and off excessively. Measured in seconds. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 7 } + +airFMSysCoolState OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the mode to enabled or disabled. Disabled modes + will not operate, and you cannot make changes to + their settings while they are disabled. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 8 } + +airFMSysCoolEssFunction OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + yes (2), + no (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the priority of the mode for alarms and events + with the nonessential stop behavior. Nonessential + modes are disabled during nonessential stop alarms + and events. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 9 } + +airFMSysCoolSetpointC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The target value for the selected control sensor air + for this mode. It must be at least 1.0 C above the + reheat setpoint if a heater is installed. Measured + in tenths of degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 10 } + +airFMSysCoolSetpointF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The target value for the selected control sensor air + for this mode. It must be at least 1.0 C above the + reheat setpoint if a heater is installed. Measured + in tenths of degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 11 } + +airFMSysCoolDeadbandC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The temperature range that controls output when the + selected control sensor temperature is above the + setpoint. At the top of this range, the cool mode + outputs at 100%. The deadband does not apply to PID- + controlled modes. Measured in tenths of degrees + Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 12 } + +airFMSysCoolDeadbandF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The temperature range that controls output when the + selected control sensor temperature is above the + setpoint. At the top of this range, the cool mode + outputs at 100%. The deadband does not apply to PID- + controlled modes. Measured in tenths of degrees + Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 13 } + +airFMSysCoolEconIsolFunction OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the Economizer Automatic Coolant Isolation valve + to enabled or disabled. This valve anticipates a + cooling demand and opens the coil fluid valve. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 14 } + +airFMSysSuctPresCompensation OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the Suction Pressure Compensation to enabled or + disabled. This function attempts to keep the suction + pressure from exceeding 95 psi. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 15 } + +airFMSysCoilFluidActivThreshC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The minimum coolant temperature required to use the + optional MultiCool or Economizer coil. Measured in + tenths of degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 16 } + +airFMSysCoilFluidActivThreshF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The minimum coolant temperature required to use the + optional MultiCool or Economizer coil. Measured in + tenths of degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 17 } + +airFMSysCoilFluidActivDeadbandC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The controller will disengage the MultiCool or + Economizer coil when the coolant temperature reaches + the coil fluid temperature activation threshold plus + the deadband. Measured in tenths of degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 18 } + +airFMSysCoilFluidActivDeadbandF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The controller will disengage the MultiCool or + Economizer coil when the coolant temperature reaches + the coil fluid temperature activation threshold plus + the deadband. Measured in tenths of degrees + Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 19 } + +airFMSysCoolPIDMethod OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + p (2), + pi (3), + pid (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the multipliers that the PID algorithm will use + to calculate the cool output. Proportional, + Proportional + Integral, or Proportional + Integral + + Derivative. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 20 } + +airFMSysCoolPIDGainP OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the proportional multiplier to correct for + differences between the selected control sensor + actual temperature and the setpoint. Measured in + %/C. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 21 } + +airFMSysCoolPIDResetRateI OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the integral multiplier to correct for the + proportional offset. Measured in %/(C * min). + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 22 } + +airFMSysCoolPIDDerivativeD OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the derivative multiplier to counteract overshoot + and droop during changes in the room load. Measured + in %/(C / min). + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysCooling 23 } + +-- airFM System Humidify Function + +airFMSysHumState OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the mode to enabled or disabled. Disabled modes + will not operate, and you cannot make changes to their + settings while they are disabled. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysHumidify 1 } + +airFMSysHumEssFunction OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + yes (2), + no (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the priority of the mode for alarms and events + with the nonessential stop behavior. Nonessential + modes are disabled during nonessential stop alarms + and events. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysHumidify 2 } + +airFMSysHumSetpoint OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The target value for the selected control sensor air + for this mode. It must be at least 1.0 % RH below + the dehumidification setpoint. Measured in tenths of + percent relative humidity. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysHumidify 3 } + +airFMSysHumDeadband OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The humidity range that controls output when the + selected control sensor humidity is below the + setpoint. At the top of this range, the + humidification mode outputs at 100%. The deadband + does not apply to PID-controlled modes. Measured in + tenths of percent relative humidity. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysHumidify 4 } + +airFMSysHumCtrlSetting OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + relativeHum (2), + dewPoint (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the method to control the humidity in the room. + The two methods are Relative Humidity (RH) or Dew + Point of the selected control sensor air. The dew + point method helps correct for hot spots near the + selected control sensors. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysHumidify 5 } + +airFMSysActualHumCtrl OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + relativeHum (2), + dewPoint (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The humidity control method the system is using. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysHumidify 6 } + +airFMSysHumSensBand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The percentage of relative humidity below the + setpoint at which the humidifier will output at 100% + of capacity. Measured in percent relative humidity. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysHumidify 7 } + +-- airFM System Dehumidify Function + +airFMSysDehumState OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the mode to enabled or disabled. Disabled modes + will not operate, and you cannot make changes to their + settings while they are disabled. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDehumidify 1 } + +airFMSysDehumEssFunction OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + yes (2), + no (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the priority of the mode for alarms and events + with the nonessential stop behavior. Nonessential + modes are disabled during nonessential stop alarms + and events. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDehumidify 2 } + +airFMSysDehumSetpoint OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The target value for the selected control sensor air + for this mode. It must be at least 1.0 % RH above + the humidification setpoint if a humidifier is + installed. Measured in tenths of percent relative + humidity. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDehumidify 3 } + +airFMSysDehumDeadband OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The humidity range above the setpoint at which the + dehumidification mode will output at 100%. The + deadband does not apply to PID controlled modes. + Measured in tenths of percent relative humidity. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDehumidify 4 } + +airFMSysDehumCapacity OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + half (2), + full (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the dehumidification mode to use either half of + the cooling coil or the full coil when dehumidifying + the room. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDehumidify 5 } + +airFMSysDehumPIDMethod OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + p (2), + pi (3), + pid (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the multipliers that the PID algorithm will use + to calculate the output. Proportional, + Proportional + Integral, or Proportional + Integral + + Derivative. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDehumidify 6 } + +airFMSysDehumPIDGainP OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the proportional multiplier to correct for + differences between the selected control sensor + actual humidity and the setpoint. Measured in %/%RH. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDehumidify 7 } + +airFMSysDehumPIDResetRateI OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the integral multiplier to correct for the + proportional offset. Measured in %/(%RH * min). + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDehumidify 8 } + +airFMSysDehumPIDDerivativeD OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the derivative multiplier to counteract overshoot + and droop during changes in the room humidity. + Measure in %/(%RH / min). + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysDehumidify 9 } + +-- airFM System Reheat Function + +airFMSysReheatState OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the mode to enabled or disabled. Disabled modes + will not operate, and you cannot make changes to their + settings while they are disabled. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysReheat 1 } + +airFMSysReheatEssFunction OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + yes (2), + no (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the priority of the mode for alarms and events + with the nonessential stop behavior. Nonessential + modes are disabled during nonessential stop alarms + and events. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysReheat 2 } + +airFMSysReheatSetpointC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The target value for the selected control sensor air + for this mode. It must be at least 1.0 C below the + cooling setpoint. Measured in tenths of degrees + Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysReheat 3 } + +airFMSysReheatSetpointF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The target value for the selected control sensor air + for this mode. It must be at least 1.0 C below the + cooling setpoint. Measured in tenths of degrees + Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysReheat 4 } + +airFMSysReheatDeadbandC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The temperature range that controls output when the + selected control sensor temperature is below the + setpoint. At the bottom of this range, the reheat + mode outputs at 100%. The deadband does not apply to + PID-controlled modes. Measured in tenths of degrees + Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysReheat 5 } + +airFMSysReheatDeadbandF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The temperature range that controls output when the + selected control sensor temperature is below the + setpoint. At the bottom of this range, the reheat + mode outputs at 100%. The deadband does not apply to + PID-controlled modes. Measured in tenths of degrees + Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysReheat 6 } + +airFMSysReheatPIDMethod OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + p (2), + pi (3), + pid (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the multipliers that the PID algorithm will use + to calculate the output. Proportional, + Proportional + Integral, or Proportional + Integral + + Derivative. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysReheat 7 } + +airFMSysReheatPIDGainP OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the proportional multiplier to correct for + differences between the selected control sensor + actual temperature and the setpoint. Measured in + %/C. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysReheat 8 } + +airFMSysReheatPIDResetRateI OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the integral multiplier to correct for the + proportional offset. Measured in %/(C * min). + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysReheat 9 } + +airFMSysReheatPIDDerivativeD OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the derivative multiplier to counteract overshoot + and droop during changes in the room load. Measured + in %/(C / min). + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysReheat 10 } + +-- airFM System Thresholds + +airFMSysHighSplyTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The high temperature threshold for air blown into the + room (supply). If the supply temperature exceeds the + threshold, an alarm will occur. Measured in tenths + of degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 1 } + +airFMSysHighSplyTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The high temperature threshold for air blown into the + room (supply). If the supply temperature exceeds the + threshold, an alarm will occur. Measured in tenths + of degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 2 } + +airFMSysLowSplyTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low temperature threshold for air blown into the + room (supply). If the supply temperature drops below + the threshold, an alarm will occur. Measured in + tenths of degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 3 } + +airFMSysLowSplyTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low temperature threshold for air blown into the + room (supply). If the supply temperature drops below + the threshold, an alarm will occur. Measured in + tenths of degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 4 } + +airFMSysHighCoilFluidTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The high temperature threshold for coolant at the + inlet to the fluid coil. If the fluid coil coolant + temperature exceeds the threshold, an alarm will + occur. Measured in tenths of degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 5 } + +airFMSysHighCoilFluidTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The high temperature threshold for coolant at the + inlet to the fluid coil. If the fluid coil coolant + temperature exceeds the threshold, an alarm will + occur. Measured in tenths of degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 6 } + +airFMSysLowCoilFluidTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low temperature threshold for coolant at the + inlet to the fluid coil. If the fluid coil coolant + temperature drops below the threshold, an alarm will + occur. Measured in tenths of degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 7 } + +airFMSysLowCoilFluidTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low temperature threshold for coolant at the + inlet to the fluid coil. If the fluid coil coolant + temperature drops below the threshold, an alarm will + occur. Measured in tenths of degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 8 } + +airFMSysHighCtrlTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The high temperature threshold for air monitored by + the System. If the temperature exceeds the threshold, + an alarm will occur. Measured in tenths of degrees + Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 9 } + +airFMSysHighCtrlTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The high temperature threshold for air monitored by + the System. If the temperature exceeds the threshold, + an alarm will occur. Measured in tenths of degrees + Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 10 } + +airFMSysLowCtrlTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low temperature threshold for air monitored by + the System. If the temperature drops below the + threshold, an alarm will occur. Measured in tenths + of degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 11 } + +airFMSysLowCtrlTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low temperature threshold for air monitored by + the System. If the temperature drops below the + threshold, an alarm will occur. Measured in tenths + of degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 12 } + +airFMSysHighCtrlHum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The high humidity threshold for air monitored by the + System. If the humidity exceeds the threshold, an + alarm will occur. Measured in tenths of percent + relative humidity. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 13 } + +airFMSysLowCtrlHum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The low humidity threshold for air monitored by the + System. If the humidity drops below the threshold, + an alarm will occur. Measured in tenths of percent + relative humidity. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 14 } + +airFMSysTempAlarmDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of time the blower must be on before a + temperature alarm can be issued. Measured in + seconds. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 15 } + +airFMSysHumAlarmDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The amount of time the blower must be on before a + humidity alarm can be issued. Measured in seconds. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysThresholds 16 } + +-- airFM System Input Contacts + +airFMSysInputTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMSysInputTable. " + ::= { airFMSysInputs 1 } + +airFMSysInputTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMSysInputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each input + contact." + ::= { airFMSysInputs 2 } + +airFMSysInputEntry OBJECT-TYPE + SYNTAX AirFMSysInputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The input contact to obtain status from." + INDEX { airFMSysInputIndex } + ::= { airFMSysInputTable 1 } + +AirFMSysInputEntry ::= + SEQUENCE { + airFMSysInputIndex INTEGER, + airFMSysInputName DisplayString, + airFMSysInputStatus INTEGER, + airFMSysInputNormalState INTEGER, + airFMSysInputDelay INTEGER, + airFMSysInputAlarmAction INTEGER + } + +airFMSysInputIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number designator of the Input Contact." + ::= { airFMSysInputEntry 1 } + +airFMSysInputName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The configurable name for the Input Contact. Maximum + text input is 13 characters." + ::= { airFMSysInputEntry 2 } + +airFMSysInputStatus OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of this contact: Open or Closed. A + violation will occur when this relay is not in its + normal state." + ::= { airFMSysInputEntry 3 } + +airFMSysInputNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the normal state of this contact (the state when + no alarm/event exists)." + ::= { airFMSysInputEntry 4 } + +airFMSysInputDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the delay between this contact exiting its normal + state and an alarm being triggered. Measured in + seconds." + ::= { airFMSysInputEntry 5 } + +airFMSysInputAlarmAction OBJECT-TYPE + SYNTAX INTEGER { + statusOnly (1), + minor (2), + major (3), + remoteRunStop (4), + nonessStop (5), + immShutdown (6) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sets the behavior for this contact when it exits its + normal state." + ::= { airFMSysInputEntry 6 } + +-- airFM System Output Relays + +airFMSysOutputTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMSysOutputTable. " + ::= { airFMSysOutputs 1 } + +airFMSysOutputTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMSysOutputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each output relay. " + ::= { airFMSysOutputs 2 } + +airFMSysOutputEntry OBJECT-TYPE + SYNTAX AirFMSysOutputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The output relay to obtain status from." + INDEX { airFMSysOutputIndex } + ::= { airFMSysOutputTable 1 } + +AirFMSysOutputEntry ::= + SEQUENCE { + airFMSysOutputIndex INTEGER, + airFMSysOutputStatus INTEGER, + airFMSysOutputNormalState INTEGER + } + +airFMSysOutputIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number designator of the output relay." + ::= { airFMSysOutputEntry 1 } + +airFMSysOutputStatus OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of this relay: Open or Closed. A violation + will occur when this relay is not in its normal state." + ::= { airFMSysOutputEntry 2 } + +airFMSysOutputNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the normal state of this relay (the state when no + alarm/event exists)." + ::= { airFMSysOutputEntry 3 } + +-- airFM System Output Alarm Mapping + +airFMSysAlarmMapSysTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMSysAlarmMapSysTable. " + ::= { airFMSysAlarmMapSys 1 } + +airFMSysAlarmMapSysTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMSysAlarmMapSysEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting alarm map information." + ::= { airFMSysAlarmMapSys 2 } + +airFMSysAlarmMapSysEntry OBJECT-TYPE + SYNTAX AirFMSysAlarmMapSysEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The system alarm map type to reference." + INDEX { airFMSysAlarmMapSysOutputIndex } + ::= { airFMSysAlarmMapSysTable 1 } + +AirFMSysAlarmMapSysEntry ::= + SEQUENCE { + airFMSysAlarmMapSysOutputIndex INTEGER, + airFMSysAlarmMapSysAnyAlarm INTEGER, + airFMSysAlarmMapSystemOn INTEGER, + airFMSysAlarmMapSystemOffline INTEGER, + airFMSysAlarmMapSysHighEnvTemp INTEGER, + airFMSysAlarmMapSysLowEnvTemp INTEGER, + airFMSysAlarmMapSysHighEnvHum INTEGER, + airFMSysAlarmMapSysLowEnvHum INTEGER, + airFMSysAlarmMapSysFireDet INTEGER, + airFMSysAlarmMapSysSmokeDet INTEGER, + airFMSysAlarmMapSysEconIsol INTEGER, + airFMSysAlarmMapSysSupplySensFail INTEGER, + airFMSysAlarmMapSysReturnSensFail INTEGER, + airFMSysAlarmMapSysRemSensRemoved INTEGER, + airFMSysAlarmMapSysPrimSensFail INTEGER, + airFMSysAlarmMapSysSecSensFail INTEGER, + airFMSysAlarmMapSysSecSensActive INTEGER + } + +airFMSysAlarmMapSysOutputIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the output relay." + ::= { airFMSysAlarmMapSysEntry 1 } + +airFMSysAlarmMapSysAnyAlarm OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for Any Alarm. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 2 } + +airFMSysAlarmMapSystemOn OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for System On. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 3 } + +airFMSysAlarmMapSystemOffline OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for System Offline. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 4 } + +airFMSysAlarmMapSysHighEnvTemp OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for High Environmental + Temperature. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 5 } + +airFMSysAlarmMapSysLowEnvTemp OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for Low Environmental + Temperature. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 6 } + +airFMSysAlarmMapSysHighEnvHum OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for High Environmental + Humidity. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 7 } + +airFMSysAlarmMapSysLowEnvHum OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for Low Environmental + Humidity. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 8 } + +airFMSysAlarmMapSysFireDet OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for Fire Detected. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 9 } + +airFMSysAlarmMapSysSmokeDet OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for Smoke Detected. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 10 } + +airFMSysAlarmMapSysEconIsol OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for Econ Isolator. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 11 } + +airFMSysAlarmMapSysSupplySensFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for Supply Sensor Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 12 } + +airFMSysAlarmMapSysReturnSensFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for Return Sensor Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 13 } + +airFMSysAlarmMapSysRemSensRemoved OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for Remote Sensor Removed. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 14 } + +airFMSysAlarmMapSysPrimSensFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for Primary Sensor Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 15 } + +airFMSysAlarmMapSysSecSensFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for Secondary Sensor Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 16 } + +airFMSysAlarmMapSysSecSensActive OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "System alarm map setting for Secondary Sensor Active. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapSysEntry 17 } + +-- airFM Main Module Output Alarm Mapping + +airFMSysAlarmMapMainModTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMSysAlarmMapMainModTable. " + ::= { airFMSysAlarmMapMainMod 1 } + +airFMSysAlarmMapMainModTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMSysAlarmMapMainModEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting alarm map information." + ::= { airFMSysAlarmMapMainMod 2 } + +airFMSysAlarmMapMainModEntry OBJECT-TYPE + SYNTAX AirFMSysAlarmMapMainModEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The main module alarm map type to reference." + INDEX { airFMSysAlarmMapMainModOutputIndex } + ::= { airFMSysAlarmMapMainModTable 1 } + +AirFMSysAlarmMapMainModEntry ::= + SEQUENCE { + airFMSysAlarmMapMainModOutputIndex INTEGER, + airFMSysAlarmMapMainModAnyAlarm INTEGER, + airFMSysAlarmMapMainModMaintReq INTEGER, + airFMSysAlarmMapMainModCoolFail INTEGER, + airFMSysAlarmMapMainModHighSupplyTemp INTEGER, + airFMSysAlarmMapMainModLowSupplyTemp INTEGER, + airFMSysAlarmMapMainModHumFail INTEGER, + airFMSysAlarmMapMainModHumReplCyl INTEGER, + airFMSysAlarmMapMainModCondPumpFail INTEGER, + airFMSysAlarmMapMainModBlwrCntl1Fail INTEGER, + airFMSysAlarmMapMainModBlwrCntl2Fail INTEGER, + airFMSysAlarmMapMainModHighFltrDP INTEGER, + airFMSysAlarmMapMainModLowAirFlow INTEGER, + airFMSysAlarmMapMainModAirBlckIntOpen INTEGER, + airFMSysAlarmMapMainModWaterDetected INTEGER + } + +airFMSysAlarmMapMainModOutputIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the output relay." + ::= { airFMSysAlarmMapMainModEntry 1 } + +airFMSysAlarmMapMainModAnyAlarm OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Main Module alarm map setting for Any Alarm. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapMainModEntry 2 } + +airFMSysAlarmMapMainModMaintReq OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Main Module alarm map setting for Module Maintenance + Required. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapMainModEntry 3 } + +airFMSysAlarmMapMainModCoolFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Main Module alarm map setting for Module Cooling + Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapMainModEntry 4 } + +airFMSysAlarmMapMainModHighSupplyTemp OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Main Module alarm map setting for High Supply + Temperature. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapMainModEntry 5 } + +airFMSysAlarmMapMainModLowSupplyTemp OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Main Module alarm map setting for Low Supply + Temperature. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapMainModEntry 6 } + +airFMSysAlarmMapMainModHumFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Main Module alarm map setting for Humidifier Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapMainModEntry 7 } + +airFMSysAlarmMapMainModHumReplCyl OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Main Module alarm map setting for Humidifier Replace + Cylinder. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapMainModEntry 8 } + +airFMSysAlarmMapMainModCondPumpFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Main Module alarm map setting for Condensate Pump + Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapMainModEntry 9 } + +airFMSysAlarmMapMainModBlwrCntl1Fail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Main Module alarm map setting for Blower Controller 1 + Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapMainModEntry 10 } + +airFMSysAlarmMapMainModBlwrCntl2Fail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Main Module alarm map setting for Blower Controller 2 + Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapMainModEntry 11 } + +airFMSysAlarmMapMainModHighFltrDP OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Main Module alarm map setting for High Filter + Differential Pressure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapMainModEntry 12 } + +airFMSysAlarmMapMainModLowAirFlow OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Main Module alarm map setting for Low Air Flow. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapMainModEntry 13 } + +airFMSysAlarmMapMainModAirBlckIntOpen OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Main Module alarm map setting for Air Block Interlock + Open. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapMainModEntry 14 } + +airFMSysAlarmMapMainModWaterDetected OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Main Module alarm map setting for Water Detected. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapMainModEntry 15 } + +-- airFM Exp Module 1 Output Alarm Mapping + +airFMSysAlarmMapExpMod1TableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMSysAlarmMapExpMod1Table. " + ::= { airFMSysAlarmMapExpMod1 1 } + +airFMSysAlarmMapExpMod1Table OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMSysAlarmMapExpMod1Entry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting alarm map information." + ::= { airFMSysAlarmMapExpMod1 2 } + +airFMSysAlarmMapExpMod1Entry OBJECT-TYPE + SYNTAX AirFMSysAlarmMapExpMod1Entry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The expansion module 1 alarm map type to reference." + INDEX { airFMSysAlarmMapExpMod1OutputIndex } + ::= { airFMSysAlarmMapExpMod1Table 1 } + +AirFMSysAlarmMapExpMod1Entry ::= + SEQUENCE { + airFMSysAlarmMapExpMod1OutputIndex INTEGER, + airFMSysAlarmMapExpMod1AnyAlarm INTEGER, + airFMSysAlarmMapExpMod1MaintReq INTEGER, + airFMSysAlarmMapExpMod1CoolFail INTEGER, + airFMSysAlarmMapExpMod1HighSupplyTemp INTEGER, + airFMSysAlarmMapExpMod1LowSupplyTemp INTEGER, + airFMSysAlarmMapExpMod1HumFail INTEGER, + airFMSysAlarmMapExpMod1HumReplCyl INTEGER, + airFMSysAlarmMapExpMod1CondPumpFail INTEGER, + airFMSysAlarmMapExpMod1BlwrCntl1Fail INTEGER, + airFMSysAlarmMapExpMod1BlwrCntl2Fail INTEGER, + airFMSysAlarmMapExpMod1HighFltrDP INTEGER, + airFMSysAlarmMapExpMod1LowAirFlow INTEGER, + airFMSysAlarmMapExpMod1AirBlckIntOpen INTEGER, + airFMSysAlarmMapExpMod1WaterDetected INTEGER + } + +airFMSysAlarmMapExpMod1OutputIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the output relay." + ::= { airFMSysAlarmMapExpMod1Entry 1 } + +airFMSysAlarmMapExpMod1AnyAlarm OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 1 alarm map setting for Any Alarm. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod1Entry 2 } + +airFMSysAlarmMapExpMod1MaintReq OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 1 alarm map setting for Module Maintenance + Required. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod1Entry 3 } + +airFMSysAlarmMapExpMod1CoolFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 1 alarm map setting for Module Cooling + Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod1Entry 4 } + +airFMSysAlarmMapExpMod1HighSupplyTemp OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 1 alarm map setting for High Supply + Temperature. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod1Entry 5 } + +airFMSysAlarmMapExpMod1LowSupplyTemp OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 1 alarm map setting for Low Supply + Temperature. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod1Entry 6 } + +airFMSysAlarmMapExpMod1HumFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 1 alarm map setting for Humidifier Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod1Entry 7 } + +airFMSysAlarmMapExpMod1HumReplCyl OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 1 alarm map setting for Humidifier Replace + Cylinder. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod1Entry 8 } + +airFMSysAlarmMapExpMod1CondPumpFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 1 alarm map setting for Condensate Pump + Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod1Entry 9 } + +airFMSysAlarmMapExpMod1BlwrCntl1Fail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 1 alarm map setting for Blower Controller 1 + Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod1Entry 10 } + +airFMSysAlarmMapExpMod1BlwrCntl2Fail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 1 alarm map setting for Blower Controller 2 + Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod1Entry 11 } + +airFMSysAlarmMapExpMod1HighFltrDP OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 1 alarm map setting for High Filter + Differential Pressure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod1Entry 12 } + +airFMSysAlarmMapExpMod1LowAirFlow OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 1 alarm map setting for Low Air Flow. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod1Entry 13 } + +airFMSysAlarmMapExpMod1AirBlckIntOpen OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 1 alarm map setting for Air Block Interlock + Open. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod1Entry 14 } + +airFMSysAlarmMapExpMod1WaterDetected OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 1 alarm map setting for Water Detected. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod1Entry 15 } + +-- airFM Expansion Module 2 Output Alarm Mapping + +airFMSysAlarmMapExpMod2TableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the + airFMSysAlarmMapExpMod2Table." + ::= { airFMSysAlarmMapExpMod2 1 } + +airFMSysAlarmMapExpMod2Table OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMSysAlarmMapExpMod2Entry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting alarm map information." + ::= { airFMSysAlarmMapExpMod2 2 } + +airFMSysAlarmMapExpMod2Entry OBJECT-TYPE + SYNTAX AirFMSysAlarmMapExpMod2Entry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The expansion module 2 alarm map type to reference." + INDEX { airFMSysAlarmMapExpMod2OutputIndex } + ::= { airFMSysAlarmMapExpMod2Table 1 } + +AirFMSysAlarmMapExpMod2Entry ::= + SEQUENCE { + airFMSysAlarmMapExpMod2OutputIndex INTEGER, + airFMSysAlarmMapExpMod2AnyAlarm INTEGER, + airFMSysAlarmMapExpMod2MaintReq INTEGER, + airFMSysAlarmMapExpMod2CoolFail INTEGER, + airFMSysAlarmMapExpMod2HighSupplyTemp INTEGER, + airFMSysAlarmMapExpMod2LowSupplyTemp INTEGER, + airFMSysAlarmMapExpMod2HumFail INTEGER, + airFMSysAlarmMapExpMod2HumReplCyl INTEGER, + airFMSysAlarmMapExpMod2CondPumpFail INTEGER, + airFMSysAlarmMapExpMod2BlwrCntl1Fail INTEGER, + airFMSysAlarmMapExpMod2BlwrCntl2Fail INTEGER, + airFMSysAlarmMapExpMod2HighFltrDP INTEGER, + airFMSysAlarmMapExpMod2LowAirFlow INTEGER, + airFMSysAlarmMapExpMod2AirBlckIntOpen INTEGER, + airFMSysAlarmMapExpMod2WaterDetected INTEGER + } + +airFMSysAlarmMapExpMod2OutputIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the output relay." + ::= { airFMSysAlarmMapExpMod2Entry 1 } + +airFMSysAlarmMapExpMod2AnyAlarm OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 2 alarm map setting for Any Alarm. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod2Entry 2 } + +airFMSysAlarmMapExpMod2MaintReq OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 2 alarm map setting for Module Maintenance + Required. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod2Entry 3 } + +airFMSysAlarmMapExpMod2CoolFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 2 alarm map setting for Module Cooling + Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod2Entry 4 } + +airFMSysAlarmMapExpMod2HighSupplyTemp OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 2 alarm map setting for High Supply + Temperature. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod2Entry 5 } + +airFMSysAlarmMapExpMod2LowSupplyTemp OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 2 alarm map setting for Low Supply + Temperature. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod2Entry 6 } + +airFMSysAlarmMapExpMod2HumFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 2 alarm map setting for Humidifier Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod2Entry 7 } + +airFMSysAlarmMapExpMod2HumReplCyl OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 2 alarm map setting for Humidifier Replace + Cylinder. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod2Entry 8 } + +airFMSysAlarmMapExpMod2CondPumpFail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 2 alarm map setting for Condensate Pump + Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod2Entry 9 } + +airFMSysAlarmMapExpMod2BlwrCntl1Fail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 2 alarm map setting for Blower Controller 1 + Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod2Entry 10 } + +airFMSysAlarmMapExpMod2BlwrCntl2Fail OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 2 alarm map setting for Blower Controller 2 + Failure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod2Entry 11 } + +airFMSysAlarmMapExpMod2HighFltrDP OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 2 alarm map setting for High Filter + Differential Pressure. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod2Entry 12 } + +airFMSysAlarmMapExpMod2LowAirFlow OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 2 alarm map setting for Low Air Flow. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod2Entry 13 } + +airFMSysAlarmMapExpMod2AirBlckIntOpen OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 2 alarm map setting for Air Block Interlock + Open. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod2Entry 14 } + +airFMSysAlarmMapExpMod2WaterDetected OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Exp Module 2 alarm map setting for Water Detected. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapExpMod2Entry 15 } + +-- airFM Input Alarm Mapping + +airFMSysAlarmMapInputTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMSysAlarmMapInputTable. " + ::= { airFMSysAlarmMapInput 1 } + +airFMSysAlarmMapInputTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMSysAlarmMapInputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting alarm map information." + ::= { airFMSysAlarmMapInput 2 } + +airFMSysAlarmMapInputEntry OBJECT-TYPE + SYNTAX AirFMSysAlarmMapInputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The input contact alarm map type to reference." + INDEX { airFMSysAlarmMapInputOutputIndex } + ::= { airFMSysAlarmMapInputTable 1 } + +AirFMSysAlarmMapInputEntry ::= + SEQUENCE { + airFMSysAlarmMapInputOutputIndex INTEGER, + airFMSysAlarmMapInput1 INTEGER, + airFMSysAlarmMapInput2 INTEGER, + airFMSysAlarmMapInput3 INTEGER, + airFMSysAlarmMapInput4 INTEGER, + airFMSysAlarmMapInput5 INTEGER, + airFMSysAlarmMapInput6 INTEGER, + airFMSysAlarmMapInput7 INTEGER, + airFMSysAlarmMapInput8 INTEGER, + airFMSysAlarmMapInput9 INTEGER, + airFMSysAlarmMapInput10 INTEGER, + airFMSysAlarmMapInput11 INTEGER, + airFMSysAlarmMapInput12 INTEGER, + airFMSysAlarmMapInput13 INTEGER, + airFMSysAlarmMapInput14 INTEGER, + airFMSysAlarmMapInput15 INTEGER, + airFMSysAlarmMapInput16 INTEGER + } + +airFMSysAlarmMapInputOutputIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the output relay." + ::= { airFMSysAlarmMapInputEntry 1 } + +airFMSysAlarmMapInput1 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 1 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 2 } + +airFMSysAlarmMapInput2 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 2 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 3 } + +airFMSysAlarmMapInput3 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 3 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 4 } + +airFMSysAlarmMapInput4 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 4 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 5 } + +airFMSysAlarmMapInput5 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 5 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 6 } + +airFMSysAlarmMapInput6 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 6 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 7 } + +airFMSysAlarmMapInput7 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 7 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 8 } + +airFMSysAlarmMapInput8 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 8 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 9 } + +airFMSysAlarmMapInput9 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 9 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 10 } + +airFMSysAlarmMapInput10 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 10 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 11 } + +airFMSysAlarmMapInput11 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 11 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 12 } + +airFMSysAlarmMapInput12 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 12 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 13 } + +airFMSysAlarmMapInput13 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 13 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 14 } + +airFMSysAlarmMapInput14 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 14 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 15 } + +airFMSysAlarmMapInput15 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 15 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 16 } + +airFMSysAlarmMapInput16 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Input contact 16 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapInputEntry 17 } + +-- airFM Output Alarm Mapping + +airFMSysAlarmMapOutputTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the + airFMSysAlarmMapOutputTable. " + ::= { airFMSysAlarmMapOutput 1 } + +airFMSysAlarmMapOutputTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMSysAlarmMapOutputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting alarm map information." + ::= { airFMSysAlarmMapOutput 2 } + +airFMSysAlarmMapOutputEntry OBJECT-TYPE + SYNTAX AirFMSysAlarmMapOutputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The input contact alarm map type to reference." + INDEX { airFMSysAlarmMapOutputIndex } + ::= { airFMSysAlarmMapOutputTable 1 } + +AirFMSysAlarmMapOutputEntry ::= + SEQUENCE { + airFMSysAlarmMapOutputIndex INTEGER, + airFMSysAlarmMapOutput1 INTEGER, + airFMSysAlarmMapOutput2 INTEGER, + airFMSysAlarmMapOutput3 INTEGER, + airFMSysAlarmMapOutput4 INTEGER, + airFMSysAlarmMapOutput5 INTEGER, + airFMSysAlarmMapOutput6 INTEGER, + airFMSysAlarmMapOutput7 INTEGER, + airFMSysAlarmMapOutput8 INTEGER, + airFMSysAlarmMapOutput9 INTEGER, + airFMSysAlarmMapOutput10 INTEGER, + airFMSysAlarmMapOutput11 INTEGER, + airFMSysAlarmMapOutput12 INTEGER, + airFMSysAlarmMapOutput13 INTEGER, + airFMSysAlarmMapOutput14 INTEGER, + airFMSysAlarmMapOutput15 INTEGER, + airFMSysAlarmMapOutput16 INTEGER + } + +airFMSysAlarmMapOutputIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the output relay." + ::= { airFMSysAlarmMapOutputEntry 1 } + +airFMSysAlarmMapOutput1 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 1 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 2 } + +airFMSysAlarmMapOutput2 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 2 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 3 } + +airFMSysAlarmMapOutput3 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 3 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 4 } + +airFMSysAlarmMapOutput4 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 4 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 5 } + +airFMSysAlarmMapOutput5 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 5 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 6 } + +airFMSysAlarmMapOutput6 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 6 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 7 } + +airFMSysAlarmMapOutput7 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 7 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 8 } + +airFMSysAlarmMapOutput8 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 8 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 9 } + +airFMSysAlarmMapOutput9 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 9 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 10 } + +airFMSysAlarmMapOutput10 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 10 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 11 } + +airFMSysAlarmMapOutput11 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 11 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 12 } + +airFMSysAlarmMapOutput12 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 12 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 13 } + +airFMSysAlarmMapOutput13 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 13 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 14 } + +airFMSysAlarmMapOutput14 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 14 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 15 } + +airFMSysAlarmMapOutput15 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 15 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 16 } + +airFMSysAlarmMapOutput16 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + disabled (2), + enabled (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Output relay 16 alarm map setting. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMSysAlarmMapOutputEntry 17 } + +-- airFM Module Identification Table + +airFMModIdentTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMModIdentTable. " + ::= { airFMModIdent 1 } + +airFMModIdentTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMModIdentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each module in + the system. " + ::= { airFMModIdent 2 } + +airFMModIdentEntry OBJECT-TYPE + SYNTAX AirFMModIdentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The module to get information from." + INDEX { airFMModIdentModuleIndex } + ::= { airFMModIdentTable 1 } + +AirFMModIdentEntry ::= + SEQUENCE { + airFMModIdentModuleIndex INTEGER, + airFMModModelNumber DisplayString, + airFMModSerialNumber DisplayString, + airFMModManufactureDate DisplayString, + airFMModFirmwareRev DisplayString, + airFMModHardwareRev DisplayString + } + +airFMModIdentModuleIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the module." + ::= { airFMModIdentEntry 1 } + +airFMModModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Model number of the Module." + ::= { airFMModIdentEntry 2 } + +airFMModSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unique identification number for this Module." + ::= { airFMModIdentEntry 3 } + +airFMModManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Date the Module was manufactured." + ::= { airFMModIdentEntry 4 } + +airFMModFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Revision number of the firmware installed on this + Module." + ::= { airFMModIdentEntry 5 } + +airFMModHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Revision number of the hardware installed on this + Module." + ::= { airFMModIdentEntry 6 } + +-- airFM Module Status Table + +airFMModStatusTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMModStatusTable. " + ::= { airFMModStatus 1 } + +airFMModStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMModStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each module in + the system. " + ::= { airFMModStatus 2 } + +airFMModStatusEntry OBJECT-TYPE + SYNTAX AirFMModStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The module to get information from." + INDEX { airFMModStatusModuleIndex } + ::= { airFMModStatusTable 1 } + +AirFMModStatusEntry ::= + SEQUENCE { + airFMModStatusModuleIndex INTEGER, + airFMModSupplyTempC INTEGER, + airFMModSupplyTempF INTEGER, + airFMModSupplyHum INTEGER, + airFMModReturnTempC INTEGER, + airFMModReturnTempF INTEGER, + airFMModReturnHum INTEGER, + airFMModFilterDiffPresPa INTEGER, + airFMModFilterDiffPresInWC INTEGER, + airFMModCoilDiffPresPa INTEGER, + airFMModCoilDiffPresInWC INTEGER + } + +airFMModStatusModuleIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the module." + ::= { airFMModStatusEntry 1 } + +airFMModSupplyTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature measured at the supply sensor. + Measured in tenths of degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModStatusEntry 2 } + +airFMModSupplyTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature measured at the supply sensor. + Measured in tenths of degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModStatusEntry 3 } + +airFMModSupplyHum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The humidity measured at the supply sensor. + Measured in tenths of percent relative humidity. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModStatusEntry 4 } + +airFMModReturnTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature measured at the return sensor. + Measured in tenths of degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModStatusEntry 5 } + +airFMModReturnTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature measured at the return sensor. + Measured in tenths of degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModStatusEntry 6 } + +airFMModReturnHum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The humidity measured at the return sensor. + Measured in tenths of percent relative humidity. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModStatusEntry 7 } + +airFMModFilterDiffPresPa OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The difference in pressure on either side of the air + filters. A high differential pressure indicates a + clogged filter. Measured in Pascals. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModStatusEntry 8 } + +airFMModFilterDiffPresInWC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The difference in pressure on either side of the air + filters. A high differential pressure indicates a + clogged filter. Measured in hundredths of inches + water column. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModStatusEntry 9 } + +airFMModCoilDiffPresPa OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The difference in pressure on either side of the + cooling/dehumidification coils. Measured in Pascals. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModStatusEntry 10 } + +airFMModCoilDiffPresInWC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The difference in pressure on either side of the + cooling/dehumidification coils. Measured in + hundredths of inches water column. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModStatusEntry 11 } + +-- airFM Module Properties Table + +airFMModPropTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMModPropTable. " + ::= { airFMModProperties 1 } + +airFMModPropTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMModPropEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each module in + the system. " + ::= { airFMModProperties 2 } + +airFMModPropEntry OBJECT-TYPE + SYNTAX AirFMModPropEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The module to get information from." + INDEX { airFMModPropModuleIndex } + ::= { airFMModPropTable 1 } + +AirFMModPropEntry ::= + SEQUENCE { + airFMModPropModuleIndex INTEGER, + airFMModOutputCapacity INTEGER, + airFMModCapacityCtrl INTEGER, + airFMModHeaterType INTEGER, + airFMModElectricHeaterType INTEGER, + airFMModHumidifierType INTEGER, + airFMModBlwrFreqSetting INTEGER, + airFMModNomCoilDiffPresPa INTEGER, + airFMModNomCoilDiffPresInWC INTEGER, + airFMModCondPump INTEGER, + airFMModFireDetector INTEGER, + airFMModSmokeDetector INTEGER, + airFMModWaterDetector INTEGER + } + +airFMModPropModuleIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the module." + ::= { airFMModPropEntry 1 } + +airFMModOutputCapacity OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + kw45 (2), + kw35 (3), + kw40 (4), + kw50 (5), + kw80 (6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The cooling capacity (in Kilowatts) of the displayed + Module. + A value of notApplicable indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModPropEntry 2 } + +airFMModCapacityCtrl OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + tandem (2), + hotGasBypass (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The method used to load and unload the compressors. + Tandem compressor Modules use two stages (one + compressor each). Single compressor Modules use hot + gas bypass. + A value of notApplicable indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModPropEntry 3 } + +airFMModHeaterType OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + none (2), + electricSCR (3), + steam (4), + hotWaterOnOff (5), + hotGasReheat (6), + hotGasAndElectric (7), + hotWaterProp (8) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of reheating device installed in this Module. + A value of notApplicable indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModPropEntry 4 } + +airFMModElectricHeaterType OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + kw10 (2), + kw15 (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type/capacity of the electric heater, if installed. + A value of notApplicable indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModPropEntry 5 } + +airFMModHumidifierType OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + none (2), + steamElectrode (3), + liveSteam (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of equipment installed in the Module to run + the humidification mode. + A value of notApplicable indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModPropEntry 6 } + +airFMModBlwrFreqSetting OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Frequency of the blower in tenths of hertz. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModPropEntry 7 } + +airFMModNomCoilDiffPresPa OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The difference in pressure on either side of the + cooling/dehumidification coils. Measured in Pascals. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModPropEntry 8 } + +airFMModNomCoilDiffPresInWC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The difference in pressure on either side of the + cooling/dehumidification coils. Measured in + hundredths of inches water column. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModPropEntry 9 } + +airFMModCondPump OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + notPresent (2), + present (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the presence of a condensate pump in the + Modules of this System. + A value of notApplicable indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModPropEntry 10 } + +airFMModFireDetector OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + notPresent (2), + present (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the presence of a fire detector for each + of the Modules in this System. + A value of notApplicable indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModPropEntry 11 } + +airFMModSmokeDetector OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + notPresent (2), + present (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the presence of a smoke detector for each + of the Modules in this System. + A value of notApplicable indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModPropEntry 12 } + +airFMModWaterDetector OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + notPresent (2), + present (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the presence of a water leak detector for + each of the Modules in this System. + A value of notApplicable indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModPropEntry 13 } + +-- airFM Module Cooling Table + +airFMModCoolTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMModCoolTable. " + ::= { airFMModCooling 1 } + +airFMModCoolTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMModCoolEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each module in + the system. " + ::= { airFMModCooling 2 } + +airFMModCoolEntry OBJECT-TYPE + SYNTAX AirFMModCoolEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The module to get information from." + INDEX { airFMModCoolModuleIndex } + ::= { airFMModCoolTable 1 } + +AirFMModCoolEntry ::= + SEQUENCE { + airFMModCoolModuleIndex INTEGER, + airFMModComp1 INTEGER, + airFMModComp2 INTEGER, + airFMModSuctPresKPa INTEGER, + airFMModSuctPresPSI INTEGER, + airFMModDischPresKPa INTEGER, + airFMModDischPresPSI INTEGER, + airFMModCondFluidVlvPos INTEGER, + airFMModCoilFluidVlvPos INTEGER + } + +airFMModCoolModuleIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the module." + ::= { airFMModCoolEntry 1 } + +airFMModComp1 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + on (2), + off (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of compressor 1 of the tandem compressor + unit (on or off). + A value of notApplicable indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModCoolEntry 2 } + +airFMModComp2 OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + on (2), + off (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of compressor 2 of the tandem compressor + unit (on or off). + A value of notApplicable indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModCoolEntry 3 } + +airFMModSuctPresKPa OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The refrigerant pressure measured at the suction + inlet of the compressor. Measured in kiloPascals. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModCoolEntry 4 } + +airFMModSuctPresPSI OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The refrigerant pressure measured at the suction + inlet of the compressor. Measured in pounds per + square inch. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModCoolEntry 5 } + +airFMModDischPresKPa OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The refrigerant pressure measured at the discharge + outlet of the compressor. Measured in kiloPascals. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModCoolEntry 6 } + +airFMModDischPresPSI OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The refrigerant pressure measured at the discharge + outlet of the compressor. Measured in pounds per + square inch. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModCoolEntry 7 } + +airFMModCondFluidVlvPos OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The position of the condenser fluid valve. The valve + regulates the flow of liquid coolant into the heat + exchanger (condenser). 100% indicates the valve is + completely open, and 0% indicates that the valve is + closed. Measured in percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModCoolEntry 8 } + +airFMModCoilFluidVlvPos OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The position of the coil fluid valve. The valve + regulates the flow of liquid coolant in the fluid + cooling coil (MultiCool, Economizer, or Chilled + Water). 100% indicates the valve is completely open, + and 0% indicates that the valve is closed. Measured + in percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModCoolEntry 9 } + + +-- airFM Module Humidity Control Table + +airFMModHumTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMModHumTable. " + ::= { airFMModHumidity 1 } + +airFMModHumTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMModHumEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each module in + the system. " + ::= { airFMModHumidity 2 } + +airFMModHumEntry OBJECT-TYPE + SYNTAX AirFMModHumEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The module to get information from." + INDEX { airFMModHumModuleIndex } + ::= { airFMModHumTable 1 } + +AirFMModHumEntry ::= + SEQUENCE { + airFMModHumModuleIndex INTEGER, + airFMModHumidifier INTEGER, + airFMModElectrodeCurrent INTEGER, + airFMModHumActualOutput INTEGER, + airFMModWaterConductivity INTEGER, + airFMModHotWaterVlvPos INTEGER, + airFMModStmElectHumMode INTEGER + } + +airFMModHumModuleIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the module." + ::= { airFMModHumEntry 1 } + +airFMModHumidifier OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + none (2), + steamElectrode (3), + liveSteam (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of equipment installed in the Module to run + the humidification mode. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModHumEntry 2 } + +airFMModElectrodeCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current drawn by the electrodes of the steam + cylinder humidifier. Measured in tenths of amps. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModHumEntry 3 } + +airFMModHumActualOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The humidification output of an individual Module. + Measured in percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModHumEntry 4 } + +airFMModWaterConductivity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The conductivity of the water in the humidifier + cylinder. Measured in microSiemens per centimeter. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModHumEntry 5 } + +airFMModHotWaterVlvPos OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The position of the hot water valve. 100% indicates + the valve is completely open, and 0% indicates that + the valve is closed. Measured in percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModHumEntry 6 } + +airFMModStmElectHumMode OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + off (2), + auto (3), + drain (4) + } + ACCESS read-write + STATUS mandatory + + DESCRIPTION + "Set the humidifier function mode. + Off: Remove power from electrodes. + Auto: Humidifier controlled by Module controller. + Drain: Remove power from electrodes and drain the cylinder. + + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModHumEntry 7 } + +-- airFM Module Blower 1 Table + +airFMModBlwr1TableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMModBlwr1Table. " + ::= { airFMModBlower1 1 } + +airFMModBlwr1Table OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMModBlwr1Entry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each module in + the system. " + ::= { airFMModBlower1 2 } + +airFMModBlwr1Entry OBJECT-TYPE + SYNTAX AirFMModBlwr1Entry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The module to get information from." + INDEX { airFMModBlwr1ModuleIndex } + ::= { airFMModBlwr1Table 1 } + +AirFMModBlwr1Entry ::= + SEQUENCE { + airFMModBlwr1ModuleIndex INTEGER, + airFMModBlwr1CtrlType INTEGER, + airFMModBlwr1CmdFreq INTEGER, + airFMModBlwr1ActFreq INTEGER, + airFMModBlwr1Poles INTEGER, + airFMModBlwr1RatedHorsePower INTEGER, + airFMModBlwr1RatedCurrent INTEGER, + airFMModBlwr1ActTorq INTEGER, + airFMModBlwr1Current INTEGER, + airFMModBlwr1Vlt INTEGER, + airFMModBlwr1DCLinkVlt INTEGER, + airFMModBlwr1AccTime INTEGER, + airFMModBlwr1DecTime INTEGER, + airFMModBlwr1CapLife INTEGER, + airFMModBlwr1CtrlCoolFanLife INTEGER, + airFMModBlwr1ElOvMode INTEGER, + airFMModBlwr1ElOvSetting INTEGER, + airFMModBlwr1ElOvTimeConst INTEGER, + airFMModBlwr1FanPower INTEGER, + airFMModBlwr1HeatsinkTempC INTEGER, + airFMModBlwr1HeatsinkTempF INTEGER, + airFMModBlwr1ChokeTempC INTEGER, + airFMModBlwr1ChokeTempF INTEGER, + airFMModBlwr1InverterTempC INTEGER, + airFMModBlwr1InverterTempF INTEGER + } + +airFMModBlwr1ModuleIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the module." + ::= { airFMModBlwr1Entry 1 } + +airFMModBlwr1CtrlType OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + fujiVFD (2), + ecController (3), + danfossVFD (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of blower controller. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 2 } + +airFMModBlwr1CmdFreq OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The requested operating frequency for the blower. + Measured in tenths of hertz. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 3 } + +airFMModBlwr1ActFreq OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frequency at which the blower controller is + operating. Measured in tenths of hertz. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 4 } + +airFMModBlwr1Poles OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of poles of the blower motor that the + blower controller is controlling. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 5 } + +airFMModBlwr1RatedHorsePower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The power rating of the blower motor. Measured in + hundredths of horsepower. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 6 } + +airFMModBlwr1RatedCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current rating of the blower motor. Measured in + hundredths of amps. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 7 } + +airFMModBlwr1ActTorq OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual torque of the blower motor. Measured in + hundredths of percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 8 } + +airFMModBlwr1Current OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The percent of rated current drawn by the blower + motor. Measured in hundredths of percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 9 } + +airFMModBlwr1Vlt OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage supplied to the blower motor. Measured + in tenths of volts RMS. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 10 } + +airFMModBlwr1DCLinkVlt OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage of the blower controller's DC bus. + Measured in volts DC. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 11 } + +airFMModBlwr1AccTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The time to accelerate the blower to the specified + frequency. Measured in tenths of seconds. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 12 } + +airFMModBlwr1DecTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The time to decelerate the blower frequency to zero. + Measured in tenths of seconds. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 13 } + +airFMModBlwr1CapLife OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The remaining life of the main circuit capacitor. + Measured in tenths of percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 14 } + +airFMModBlwr1CtrlCoolFanLife OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total operation time of the blower controller + cooling fan. Measured in hours. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 15 } + +airFMModBlwr1ElOvMode OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + inactive (2), + active (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Enables or disables the electronic overload relay. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 16 } + +airFMModBlwr1ElOvSetting OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The electronic overload relay is activated when the + current exceeds this threshold. Measured in + hundredths of amps. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 17 } + +airFMModBlwr1ElOvTimeConst OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The delay between the current exceeding the overload + threshold and the activation of the electronic + overload relay. Measured in tenths of minutes. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 18 } + +airFMModBlwr1FanPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual power of the blower motor. Measured in + tenths of percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 19 } + +airFMModBlwr1HeatsinkTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the heatsink on the blower + controller. Measured in degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 20 } + +airFMModBlwr1HeatsinkTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the heatsink on the blower + controller. Measured in degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 21 } + +airFMModBlwr1ChokeTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the choke on the blower + controller. Measured in degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 22 } + +airFMModBlwr1ChokeTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the choke on the blower + controller. Measured in degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 23 } + +airFMModBlwr1InverterTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the inverter on the blower + controller. Measured in degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 24 } + +airFMModBlwr1InverterTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the inverter on the blower + controller. Measured in degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr1Entry 25 } + + +-- airFM Module Blower 2 Table + +airFMModBlwr2TableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMModBlwr2Table. " + ::= { airFMModBlower2 1 } + +airFMModBlwr2Table OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMModBlwr2Entry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each module in + the system. " + ::= { airFMModBlower2 2 } + +airFMModBlwr2Entry OBJECT-TYPE + SYNTAX AirFMModBlwr2Entry + + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The module to get information from." + INDEX { airFMModBlwr2ModuleIndex } + ::= { airFMModBlwr2Table 1 } + +AirFMModBlwr2Entry ::= + SEQUENCE { + airFMModBlwr2ModuleIndex INTEGER, + airFMModBlwr2CtrlType INTEGER, + airFMModBlwr2CmdFreq INTEGER, + airFMModBlwr2ActFreq INTEGER, + airFMModBlwr2Poles INTEGER, + airFMModBlwr2RatedHorsePower INTEGER, + airFMModBlwr2RatedCurrent INTEGER, + airFMModBlwr2ActTorq INTEGER, + airFMModBlwr2Current INTEGER, + airFMModBlwr2Vlt INTEGER, + airFMModBlwr2DCLinkVlt INTEGER, + airFMModBlwr2AccTime INTEGER, + airFMModBlwr2DecTime INTEGER, + airFMModBlwr2CapLife INTEGER, + airFMModBlwr2CtrlCoolFanLife INTEGER, + airFMModBlwr2ElOvMode INTEGER, + airFMModBlwr2ElOvSetting INTEGER, + airFMModBlwr2ElOvTimeConst INTEGER, + airFMModBlwr2FanPower INTEGER, + airFMModBlwr2HeatsinkTempC INTEGER, + airFMModBlwr2HeatsinkTempF INTEGER, + airFMModBlwr2ChokeTempC INTEGER, + airFMModBlwr2ChokeTempF INTEGER, + airFMModBlwr2InverterTempC INTEGER, + airFMModBlwr2InverterTempF INTEGER + } + +airFMModBlwr2ModuleIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the module." + ::= { airFMModBlwr2Entry 1 } + +airFMModBlwr2CtrlType OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + fujiVFD (2), + ecController (3), + danfossVFD (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of blower controller. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 2 } + +airFMModBlwr2CmdFreq OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The requested operating frequency for the blower. + Measured in tenths of hertz. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 3 } + +airFMModBlwr2ActFreq OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frequency at which the blower controller is + operating. Measured in tenths of hertz. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 4 } + +airFMModBlwr2Poles OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of poles of the blower motor that the + blower controller is controlling. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 5 } + +airFMModBlwr2RatedHorsePower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The power rating of the blower motor. Measured in + hundredths of horsepower. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 6 } + +airFMModBlwr2RatedCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current rating of the blower motor. Measured in + hundredths of amps. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 7 } + +airFMModBlwr2ActTorq OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual torque of the blower motor. Measured in + hundredths of percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 8 } + +airFMModBlwr2Current OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The percent of rated current drawn by the blower + motor. Measured in hundredths of percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 9 } + +airFMModBlwr2Vlt OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage supplied to the blower motor. Measured + in tenths of volts RMS. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 10 } + +airFMModBlwr2DCLinkVlt OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage of the blower controller's DC bus. + Measured in volts DC. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 11 } + +airFMModBlwr2AccTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The time to accelerate the blower to the specified + frequency. Measured in tenths of seconds. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 12 } + +airFMModBlwr2DecTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The time to decelerate the blower frequency to zero. + Measured in tenths of seconds. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 13 } + +airFMModBlwr2CapLife OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The remaining life of the main circuit capacitor. + Measured in tenths of percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 14 } + +airFMModBlwr2CtrlCoolFanLife OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total operation time of the blower controller + cooling fan. Measured in hours. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 15 } + +airFMModBlwr2ElOvMode OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + inactive (2), + active (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Enables or disables the electronic overload relay. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 16 } + +airFMModBlwr2ElOvSetting OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The electronic overload relay is activated when the + current exceeds this threshold. Measured in + hundredths of amps. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 17 } + +airFMModBlwr2ElOvTimeConst OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The delay between the current exceeding the overload + threshold and the activation of the electronic + overload relay. Measured in tenths of minutes. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 18 } + +airFMModBlwr2FanPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual power of the blower motor. Measured in + tenths of percent. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 19 } + +airFMModBlwr2HeatsinkTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the heatsink on the blower + controller. Measured in degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 20 } + +airFMModBlwr2HeatsinkTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the heatsink on the blower + controller. Measured in degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 21 } + +airFMModBlwr2ChokeTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the choke on the blower + controller. Measured in degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 22 } + +airFMModBlwr2ChokeTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the choke on the blower + controller. Measured in degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 23 } + +airFMModBlwr2InverterTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the inverter on the blower + controller. Measured in degrees Celsius. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 24 } + +airFMModBlwr2InverterTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the inverter on the blower + controller. Measured in degrees Fahrenheit. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModBlwr2Entry 25 } + +-- airFM Module Run Hours Table + +airFMModRHTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMModRHTable. " + ::= { airFMModRunHours 1 } + +airFMModRHTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMModRHEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each module in + the system. " + ::= { airFMModRunHours 2 } + +airFMModRHEntry OBJECT-TYPE + SYNTAX AirFMModRHEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The module to get information from." + INDEX { airFMModRHModuleIndex } + ::= { airFMModRHTable 1 } + +AirFMModRHEntry ::= + SEQUENCE { + airFMModRHModuleIndex INTEGER, + airFMModRHComp1 INTEGER, + airFMModRHComp2 INTEGER, + airFMModRHHeater INTEGER, + airFMModRHHum INTEGER, + airFMModRHBlwr1 INTEGER, + airFMModRHBlwr2 INTEGER, + airFMModRHBlwrCtrl1 INTEGER, + airFMModRHBlwrCtrl2 INTEGER, + airFMModRHComp1Reset INTEGER, + airFMModRHComp2Reset INTEGER, + airFMModRHHeaterReset INTEGER, + airFMModRHHumReset INTEGER, + airFMModRHBlwr1Reset INTEGER, + airFMModRHBlwr2Reset INTEGER + } + +airFMModRHModuleIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the module." + ::= { airFMModRHEntry 1 } + +airFMModRHComp1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor 1 run hours. + A value of -2147483648 indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModRHEntry 2 } + +airFMModRHComp2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor 2 run hours. + A value of -2147483648 indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModRHEntry 3 } + +airFMModRHHeater OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Heater run hours. + A value of -2147483648 indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModRHEntry 4 } + +airFMModRHHum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier run hours + A value of -2147483648 indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModRHEntry 5 } + +airFMModRHBlwr1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Blower 1 run hours. + A value of -2147483648 indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModRHEntry 6 } + +airFMModRHBlwr2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Blower 2 run hours. + A value of -2147483648 indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModRHEntry 7 } + +airFMModRHBlwrCtrl1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Blower Controller 1 run hours. + A value of -2147483648 indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModRHEntry 8 } + +airFMModRHBlwrCtrl2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Blower Controller 2 run hours. + A value of -2147483648 indicates that this OID + does not apply to this device due to its configuration." + ::= { airFMModRHEntry 9 } + +airFMModRHComp1Reset OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset the compressor 1 run hours. + Getting this OID will do nothing and return the + noOperation value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModRHEntry 10 } + +airFMModRHComp2Reset OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset the compressor 2 run hours. + Getting this OID will do nothing and return the + noOperation value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModRHEntry 11 } + +airFMModRHHeaterReset OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset the heater run hours. + Getting this OID will do nothing and return the + noOperation value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModRHEntry 12 } + +airFMModRHHumReset OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset the humidifier run hours. + Getting this OID will do nothing and return the + noOperation value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModRHEntry 13 } + +airFMModRHBlwr1Reset OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset the blower 1 run hours. + Getting this OID will do nothing and return the + noOperation value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModRHEntry 14 } + +airFMModRHBlwr2Reset OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset the blower 2 run hours. + Getting this OID will do nothing and return the + noOperation value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModRHEntry 15 } + +-- airFM Module Service Intervals + +airFMModServIntComp1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The interval at which to generate a maintenance alarm + for compressor 1. Values stored in increments of 100 + hours. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntervals 1 } + +airFMModServIntComp2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The interval at which to generate a maintenance alarm + for compressor 2. Values stored in increments of 100 + hours. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntervals 2 } + +airFMModServIntHeater OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The interval at which to generate a maintenance alarm + for the reheat components. Values stored in + increments of 100 hours. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntervals 3 } + +airFMModServIntHum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The interval at which to generate a maintenance alarm + for the humidifier. Values stored in increments of + 100 hours. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntervals 4 } + +airFMModServIntBlwr1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The interval at which to generate a maintenance alarm + for blower 1. Values stored in increments of 100 + hours. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntervals 5 } + +airFMModServIntBlwr2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The interval at which to generate a maintenance alarm + for blower 2. Values stored in increments of 100 + hours. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntervals 6 } + +airFMModServIntBlwrCtrl1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The interval at which to generate a maintenance alarm + for blower controller 1. Values stored in increments + of 100 hours. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntervals 7 } + +airFMModServIntBlwrCtrl2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The interval at which to generate a maintenance alarm + for blower controller 2. Values stored in increments + of 100 hours. + A value of -2147483648 indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntervals 8 } + +-- airFM Module Service Intervals Reset Table + +airFMModServIntResetTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the airFMModServIntTable. " + ::= { airFMModServIntResets 1 } + +airFMModServIntResetTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMModServIntResetEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each module in + the system. " + ::= { airFMModServIntResets 2 } + +airFMModServIntResetEntry OBJECT-TYPE + SYNTAX AirFMModServIntResetEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The module to get information from." + INDEX { airFMModServIntResetModuleIndex } + ::= { airFMModServIntResetTable 1 } + +AirFMModServIntResetEntry ::= + SEQUENCE { + airFMModServIntResetModuleIndex INTEGER, + airFMModServIntComp1Reset INTEGER, + airFMModServIntComp2Reset INTEGER, + airFMModServIntHeaterReset INTEGER, + airFMModServIntHumReset INTEGER, + airFMModServIntBlwr1Reset INTEGER, + airFMModServIntBlwr2Reset INTEGER, + airFMModServIntBlwrCtrl1Reset INTEGER, + airFMModServIntBlwrCtrl2Reset INTEGER + } + +airFMModServIntResetModuleIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the module." + ::= { airFMModServIntResetEntry 1 } + +airFMModServIntComp1Reset OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset the compressor 1 service interval maintenance + alarm. + Getting this OID will do nothing and return the + noOperation value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntResetEntry 2 } + +airFMModServIntComp2Reset OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset the compressor 2 service interval maintenance + alarm. + Getting this OID will do nothing and return the + noOperation value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntResetEntry 3 } + +airFMModServIntHeaterReset OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset the heater service interval maintenance alarm. + Getting this OID will do nothing and return the + noOperation value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntResetEntry 4 } + +airFMModServIntHumReset OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset the humidifier service interval maintenance + alarm. + Getting this OID will do nothing and return the + noOperation value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntResetEntry 5 } + +airFMModServIntBlwr1Reset OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset the blower 1 service interval maintenance + alarm. + Getting this OID will do nothing and return the + noOperation value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntResetEntry 6 } + +airFMModServIntBlwr2Reset OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset the blower 2 service interval maintenance + alarm. + Getting this OID will do nothing and return the + noOperation value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntResetEntry 7 } + +airFMModServIntBlwrCtrl1Reset OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset the blower controller 1 service interval + maintenance alarm. + Getting this OID will do nothing and return the + noOperation value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntResetEntry 8 } + +airFMModServIntBlwrCtrl2Reset OBJECT-TYPE + SYNTAX INTEGER { + notApplicable (1), + noOperation (2), + reset (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset the blower controller 2 service interval + maintenance alarm. + Getting this OID will do nothing and return the + noOperation value. + A value of notApplicable indicates that this OID does + not apply to this device due to its configuration." + ::= { airFMModServIntResetEntry 9 } + +-- airFM Alarms Table + +airFMAlarmClearActiveGroupAlarms OBJECT-TYPE + SYNTAX INTEGER { + noOperation (1), + clearAlarms (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Clear active group alarms. If alarm conditions are + still present, new alarms will be generated for those + conditions. + Getting this OID will do nothing and return the + noOperation value." + ::= { airFMAlarms 1 } + +airFMAlarmClearActiveSysModAlarms OBJECT-TYPE + SYNTAX INTEGER { + noOperation (1), + clearAlarms (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Clear active system and module alarms. If alarm + conditions are still present, new alarms will be + generated for those conditions. + Getting this OID will do nothing and return the + noOperation value." + ::= { airFMAlarms 2 } + +airFMAlarmConditionsTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of active alarm conditions in the + airFMAlarmConditionTable." + ::= { airFMAlarms 3 } + +airFMAlarmConditionsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFMAlarmConditionsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Table of active alarm conditions for the device." + ::= { airFMAlarms 4 } + +airFMAlarmConditionsEntry OBJECT-TYPE + SYNTAX AirFMAlarmConditionsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "Alarm condition specification" + INDEX { airFMAlarmConditionsIndex } + ::= { airFMAlarmConditionsTable 1 } + +AirFMAlarmConditionsEntry ::= SEQUENCE { + airFMAlarmConditionsIndex INTEGER, + airFMAlarmSeverity INTEGER, + airFMAlarmType INTEGER, + airFMEventCode INTEGER, + airFMAlarmDate DisplayString, + airFMAlarmTime DisplayString, + airFMAlarmDescription DisplayString + } + +airFMAlarmConditionsIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Alarm condition index." + ::= { airFMAlarmConditionsEntry 1 } + +airFMAlarmSeverity OBJECT-TYPE + SYNTAX INTEGER { + informational (1), + warningMinor (2), + criticalMajor (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION "Severity of the alarm." + ::= { airFMAlarmConditionsEntry 2 } + +airFMAlarmType OBJECT-TYPE + SYNTAX INTEGER { + group (1), + system (2), + mainMod (3), + expMod1 (4), + expMod2 (5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION "Type of alarm." + ::= { airFMAlarmConditionsEntry 3 } + +airFMEventCode OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "APC event code for the alarm." + ::= { airFMAlarmConditionsEntry 4 } + +airFMAlarmDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "Date the alarm was recorded." + ::= { airFMAlarmConditionsEntry 5 } + +airFMAlarmTime OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION "Time the alarm was recorded." + ::= { airFMAlarmConditionsEntry 6 } + +airFMAlarmDescription OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..64)) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Description of the alarm." + ::= { airFMAlarmConditionsEntry 7 } + +-- airPA Portable Air Conditioner Ident + +airPAIdentName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the device name." + ::= { airPAIdent 1 } + +airPAModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the device model number." + ::= { airPAIdent 2 } + +airPADateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying when the device was produced." + ::= { airPAIdent 3 } + +airPASerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the device serial number." + ::= { airPAIdent 4 } + +airPAFirmwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the device firmware revision." + ::= { airPAIdent 5 } + +airPAHardwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the device hardware revision." + ::= { airPAIdent 6 } + +-- airPA Portable Air Conditioner Status + +airPASystemPower OBJECT-TYPE + SYNTAX INTEGER { + powerON (1), + powerOFF (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the unit's system power setting. + + ON(1) The system power is turned on. + OFF(2) The system power is turned off. " + ::= { airPAStatus 1 } + +airPAOperatingMode OBJECT-TYPE + SYNTAX INTEGER { + modeOFF (1), + modeVENTING (2), + modeCOOLING (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current operating mode of the unit. + + OFF(1) The system is off. + VENTING(2) The system's venting function is active. + COOLING(3) The system's cooling function is active. " + ::= { airPAStatus 2 } + +airPASetpointTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature setpoint in Fahrenheit to which the unit is controlling. " + ::= { airPAStatus 3 } + +airPASetpointTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature setpoint in Celsius to which the unity is controlling. " + ::= { airPAStatus 4 } + +airPABlowerSpeed OBJECT-TYPE + SYNTAX INTEGER { + speedLOW (1), + speedHIGH (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit's blower speed setting. + + LOW(1) The blower speed is low. + HIGH(2) The blower speed is high. " + ::= { airPAStatus 5 } + +airPACompressor OBJECT-TYPE + SYNTAX INTEGER { + statusON (1), + statusOFF (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit's compressor status. + + ON(1) The compressor is turned on. + OFF(2) The compressor is turned off. " + ::= { airPAStatus 6 } + +airPACondenserFan OBJECT-TYPE + SYNTAX INTEGER { + statusON (1), + statusOFF (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit's condenser fan status. + + ON(1) The condenser fan is turned on. + OFF(2) The condenser fan is turned off. " + ::= { airPAStatus 7 } + +airPACondensatePump OBJECT-TYPE + SYNTAX INTEGER { + statusON (1), + statusOFF (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit's condensate pump status. + + ON(1) The condensate pump is turned on. + OFF(2) The condensate pump is turned off. " + ::= { airPAStatus 8 } + +airPASupplyTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The supply temperature in degrees Fahrenheit. " + ::= { airPAStatus 9 } + +airPASupplyTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The supply temperature in degrees Celsius. " + ::= { airPAStatus 10 } + +airPAReturnTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The return temperature in degrees Fahrenheit. " + ::= { airPAStatus 11 } + +airPAReturnTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The return temperature in degrees Celsius. " + ::= { airPAStatus 12 } + +airPARemoteTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The remote temperature in degrees Fahrenheit. " + ::= { airPAStatus 13 } + +airPARemoteTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The remote temperature in degrees Celsius. " + ::= { airPAStatus 14 } + +airPARemoteHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The remote humidity. " + ::= { airPAStatus 15 } + +-- air InRow Air Conditioners +-- airIR AIR CONDITIONER Alarm Status - shared across all IR products + +airIRAlarmConditionsTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of active alarm conditions in the airIRAlarmConditionTable." + ::= { airIRAlarms 1 } + +airIRAlarmConditionsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRAlarmConditionsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Table of active alarm conditions for the device." + ::= { airIRAlarms 2 } + +airIRAlarmConditionsEntry OBJECT-TYPE + SYNTAX AirIRAlarmConditionsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "Alarm condition specification" + INDEX { airIRAlarmConditionsIndex } + ::= { airIRAlarmConditionsTable 1 } + +AirIRAlarmConditionsEntry ::= SEQUENCE { + airIRAlarmConditionsIndex INTEGER, + airIREventCode INTEGER, + airIRAlarmDescription DisplayString + } + +airIRAlarmConditionsIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Alarm condition index." + ::= { airIRAlarmConditionsEntry 1 } + +airIREventCode OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Code for the alarm." + ::= { airIRAlarmConditionsEntry 2 } + +airIRAlarmDescription OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..64)) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Description of the alarm." + ::= { airIRAlarmConditionsEntry 3 } + +-- airIRRC AIR CONDITIONER Group Status + +airIRRCGroupStatusCoolOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group coolant output in tenths of kW." + ::= { airIRRCGroupStatus 1 } + +airIRRCGroupStatusCoolDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group coolant demand in tenths of kW." + ::= { airIRRCGroupStatus 2 } + +airIRRCGroupStatusAirFlowUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group air flow in cubic feet per minute." + ::= { airIRRCGroupStatus 3 } + +airIRRCGroupStatusAirFlowMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group air flow in liters per second." + ::= { airIRRCGroupStatus 4 } + +airIRRCGroupStatusMaxRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group maximum rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRRCGroupStatus 5 } + +airIRRCGroupStatusMaxRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group maximum rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRRCGroupStatus 6 } + +airIRRCGroupStatusMinRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group minimum rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRRCGroupStatus 7 } + +airIRRCGroupStatusMinRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group minimum rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRRCGroupStatus 8 } + +airIRRCGroupStatusActiveFlowControlStatus OBJECT-TYPE + SYNTAX INTEGER { + under (1), + okay (2), + over (3), + notApplicable (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Status of the active flow control + system." + ::= { airIRRCGroupStatus 9 } + + +-- airIRRC AIR CONDITIONER Group Setpoints + +airIRRCGroupSetpointsCoolUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling setpoint in tenths of + degrees Fahrenheit." + ::= { airIRRCGroupSetpoints 1 } + +airIRRCGroupSetpointsCoolMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling setpoint in tenths of + degrees Celsius." + ::= { airIRRCGroupSetpoints 2 } + +airIRRCGroupSetpointsSupplyAirUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Fahrenheit." + ::= { airIRRCGroupSetpoints 3 } + +airIRRCGroupSetpointsSupplyAirMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Celsius." + ::= { airIRRCGroupSetpoints 4 } + +airIRRCGroupSetpointsFanSpeedPreference OBJECT-TYPE + SYNTAX INTEGER { + low (1), + med-low (2), + med (3), + med-high (4), + high (5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The preferred fan speed setting." + ::= { airIRRCGroupSetpoints 5 } + +airIRRCGroupSetpointsFanSpeedControl OBJECT-TYPE + SYNTAX INTEGER { + automatic (1), + manual (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The fan speed control setting. + Automatic(1) - controller manages fan speed. + Manual(2) - fan speed is fixed and set by the fan speed preference. + See airIRRCGroupSetpointsFanSpeedPreference." + ::= { airIRRCGroupSetpoints 6 } + +airIRRCGroupSetpointsActiveFlowControlBias OBJECT-TYPE + SYNTAX INTEGER { + positive (1), + slightlyPositive (2), + zero (3), + slightlyNegative (4), + negative (5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The active flow control bias setting." + ::= { airIRRCGroupSetpoints 7 } + +-- airIRRC AIR CONDITIONER Group Config + +airIRRCGroupConfigNumberofCoolingUnits OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of cooling units present in the group." + ::= { airIRRCGroupConfig 1 } + +airIRRCGroupConfigConfigurationType OBJECT-TYPE + SYNTAX INTEGER { + racs (1), + hacs (2), + in-row (3), + cacs (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group configuration type." + ::= { airIRRCGroupConfig 2 } + +airIRRCGroupConfigPctGlycol OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The glycol mixture in percent." + ::= { airIRRCGroupConfig 3 } + +airIRRCGroupConfigCoolGainP OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The gain component of the PID in hundredths." + ::= { airIRRCGroupConfig 4 } + +airIRRCGroupConfigCoolResetRateI OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The integral component of the PID in hundredths." + ::= { airIRRCGroupConfig 5 } + +airIRRCGroupConfigCoolDerivativeD OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The derivative component of the PID in hundredths." + ::= { airIRRCGroupConfig 6 } + +airIRRCGroupConfigMaxFanSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum desired fan speed setting in percent." + ::= { airIRRCGroupConfig 7 } + +airIRRCGroupConfigNumberOfActiveFlowControllers OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of active flow controllers + present in the group." + ::= { airIRRCGroupConfig 8 } + +airIRRCGroupConfigActiveFlowControllerLampTest OBJECT-TYPE + SYNTAX INTEGER { + off (1), + on (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Turns off/on the active flow + controller lamp test." + ::= { airIRRCGroupConfig 9 } + +airIRRCGroupConfigAltitudeUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group altitude of the units above sea level in feet." + ::= { airIRRCGroupConfig 10 } + +airIRRCGroupConfigAltitudeMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group altitude of the units above sea level in meters." + ::= { airIRRCGroupConfig 11 } + +-- airIRRC AIR CONDITIONER UNIT Status + +airIRRCUnitStatusOperateMode OBJECT-TYPE + SYNTAX INTEGER { + standby (1), + on (2), + idle (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The cooling unit operating mode." + ::= { airIRRCUnitStatus 1 } + +airIRRCUnitStatusCoolOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit cooling output in tenths of kW." + ::= { airIRRCUnitStatus 2 } + +airIRRCUnitStatusCoolDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit cooling demand in tenths of kW." + ::= { airIRRCUnitStatus 3 } + +airIRRCUnitStatusAirFlowUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air flow in cubic feet per minute." + ::= { airIRRCUnitStatus 4 } + +airIRRCUnitStatusAirFlowMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air flow in hundredths of + liters per second." + ::= { airIRRCUnitStatus 5 } + +airIRRCUnitStatusRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRRCUnitStatus 6 } + +airIRRCUnitStatusRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRRCUnitStatus 7 } + +airIRRCUnitStatusSupplyAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit supply air temperature in tenths of + degrees Fahrenheit." + ::= { airIRRCUnitStatus 8 } + +airIRRCUnitStatusSupplyAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit supply air temperature in tenths of + degrees Celsius." + ::= { airIRRCUnitStatus 9 } + +airIRRCUnitStatusReturnAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit return air temperature in tenths of + degrees Fahrenheit." + ::= { airIRRCUnitStatus 10 } + +airIRRCUnitStatusReturnAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit return air temperature in tenths of + degrees Celsius." + ::= { airIRRCUnitStatus 11 } + +airIRRCUnitStatusContainmtDPUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit containment differential pressure in + hundredths of inches of water." + ::= { airIRRCUnitStatus 12 } + +airIRRCUnitStatusContainmtDPMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit containment differential pressure in Pa." + ::= { airIRRCUnitStatus 13 } + +airIRRCUnitStatusFilterDPUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air filter differential pressure in + hundredths of inches of water." + ::= { airIRRCUnitStatus 14 } + +airIRRCUnitStatusFilterDPMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air filter differential pressure in Pa." + ::= { airIRRCUnitStatus 15 } + +airIRRCUnitStatusFanSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit average fan speed in tenths of percent." + ::= { airIRRCUnitStatus 16 } + +airIRRCUnitStatusInputState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the input contact." + ::= { airIRRCUnitStatus 17 } + +airIRRCUnitStatusOutputState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the output relay." + ::= { airIRRCUnitStatus 18 } + +airIRRCUnitStatusActivePowerSource OBJECT-TYPE + SYNTAX INTEGER { + sourceA (1), + sourceB (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The power source that is powering the unit." + ::= { airIRRCUnitStatus 19 } + +airIRRCUnitStatusFluidValvePosition OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The fluid valve position in percent open." + ::= { airIRRCUnitStatus 20 } + +airIRRCUnitStatusFluidFlowUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The fluid flow in tenths of gallons per minute." + ::= { airIRRCUnitStatus 21 } + +airIRRCUnitStatusFluidFlowMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The fluid flow in hundredths of liters per second." + ::= { airIRRCUnitStatus 22 } + +airIRRCUnitStatusEnteringFluidTemperatureUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the entering fluid in + tenths of degrees Fahrenheit." + ::= { airIRRCUnitStatus 23 } + +airIRRCUnitStatusEnteringFluidTemperatureMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the entering fluid in + tenths of degrees Celsius." + ::= { airIRRCUnitStatus 24 } + +airIRRCUnitStatusLeavingFluidTemperatureUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the Leaving fluid in + tenths of degrees Fahrenheit." + ::= { airIRRCUnitStatus 25 } + +airIRRCUnitStatusLeavingFluidTemperatureMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the Leaving fluid in + tenths of degrees Celsius." + ::= { airIRRCUnitStatus 26 } + + +-- airIRRC AIR CONDITIONER UNIT Ident + +airIRRCUnitIdentID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The unit identification number." + ::= { airIRRCUnitIdent 1 } + +airIRRCUnitIdentName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit name." + ::= { airIRRCUnitIdent 2 } + +airIRRCUnitIdentLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit location." + ::= { airIRRCUnitIdent 3 } + +airIRRCUnitIdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit model number." + ::= { airIRRCUnitIdent 4 } + +airIRRCUnitIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit serial number." + ::= { airIRRCUnitIdent 5 } + +airIRRCUnitIdentFirmwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit firmware version." + ::= { airIRRCUnitIdent 6 } + +airIRRCUnitIdentHardwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit controller hardware revision." + ::= { airIRRCUnitIdent 7 } + +airIRRCUnitIdentManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit manufacture date." + ::= { airIRRCUnitIdent 8 } + + +-- airIRRC AIR CONDITIONER UNIT Runhours + +airIRRCUnitRunHoursAirFilter OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit air filter run hours." + ::= { airIRRCUnitRunHours 1 } + +airIRRCUnitRunHoursFan1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan 1 run hours." + ::= { airIRRCUnitRunHours 2 } + +airIRRCUnitRunHoursFan2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan 2 run hours." + ::= { airIRRCUnitRunHours 3 } + +airIRRCUnitRunHoursFan3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan 3 run hours." + ::= { airIRRCUnitRunHours 4 } + +airIRRCUnitRunHoursFan4 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan 4 run hours." + ::= { airIRRCUnitRunHours 5 } + +airIRRCUnitRunHoursFan5 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan 5 run hours." + ::= { airIRRCUnitRunHours 6 } + +airIRRCUnitRunHoursFan6 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan 6 run hours." + ::= { airIRRCUnitRunHours 7 } + +airIRRCUnitRunHoursFan7 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan 7 run hours." + ::= { airIRRCUnitRunHours 8} + +airIRRCUnitRunHoursFan8 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan 8 run hours." + ::= { airIRRCUnitRunHours 9 } + +airIRRCUnitRunHoursFanPowerSupplyLeft OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan left power supply run hours." + ::= { airIRRCUnitRunHours 10 } + +airIRRCUnitRunHoursFanPowerSupplyRight OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan right power supply run hours." + ::= { airIRRCUnitRunHours 11 } + +airIRRCUnitRunHoursCondensatePump OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit condensate pump run hours." + ::= { airIRRCUnitRunHours 12 } + + +-- airIRRC AIR CONDITIONER UNIT Service Intervals + +airIRRCUnitServiceIntervalsAirFilter OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Air filter service interval in weeks." + ::= { airIRRCUnitServiceIntervals 1 } + +airIRRCUnitServiceIntervalsAirFilterAlarm OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The air filter service interval alarm enable/disable." + ::= { airIRRCUnitServiceIntervals 2 } + + +-- airIRRC AIR CONDITIONER UNIT Thresholds + +airIRRCUnitThresholdsRackInletHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit rack inlet air high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRRCUnitThresholds 1 } + +airIRRCUnitThresholdsRackInletHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit rack inlet air high temperature threshold in + tenths of degrees Celsius." + ::= { airIRRCUnitThresholds 2 } + +airIRRCUnitThresholdsSupplyAirHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply air high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRRCUnitThresholds 3 } + +airIRRCUnitThresholdsSupplyAirHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply air high temperature threshold in + tenths of degrees Celsius." + ::= { airIRRCUnitThresholds 4 } + +airIRRCUnitThresholdsReturnAirHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit return air high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRRCUnitThresholds 5 } + +airIRRCUnitThresholdsReturnAirHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit return air high temperature threshold in + tenths of degrees Celsius." + ::= { airIRRCUnitThresholds 6 } + +airIRRCUnitThresholdsEnteringFluidHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit entering fluid high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRRCUnitThresholds 7 } + +airIRRCUnitThresholdsEnteringFluidHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit incoming fluid high temperature threshold in + tenths of degrees Celsius." + ::= { airIRRCUnitThresholds 8 } + + +-- airIRRC AIR CONDITIONER UNIT Config + +airIRRCUnitConfigCoolCapacity OBJECT-TYPE + SYNTAX INTEGER { + automatic (1), + maximum (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The cooling capacity options setting." + ::= { airIRRCUnitConfig 1 } + +airIRRCUnitConfigStartupDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The startup delay in seconds." + ::= { airIRRCUnitConfig 2 } + +airIRRCUnitConfigIdleOnLeakDetect OBJECT-TYPE + SYNTAX INTEGER { + yes (1), + no (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The idle on leak options setting." + ::= { airIRRCUnitConfig 3 } + +airIRRCUnitConfigPowerSource OBJECT-TYPE + SYNTAX INTEGER { + sourceA (1), + sourceB (2), + sourceAandB (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The configured power source of the unit." + ::= { airIRRCUnitConfig 4 } + +airIRRCUnitConfigInputNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal state of the input contact." + ::= { airIRRCUnitConfig 5 } + +airIRRCUnitConfigOutputNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal state of the output relay." + ::= { airIRRCUnitConfig 6 } + +airIRRCUnitConfigOutputSource OBJECT-TYPE + SYNTAX INTEGER { + anyAlarm (1), + criticalAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The source of output relay change." + ::= { airIRRCUnitConfig 7 } + +airIRRCUnitConfigIdleOnCoolFail OBJECT-TYPE + SYNTAX INTEGER { + yes (1), + no (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The idle on cool fail options setting. + If yes, the system will go into idle mode + when a cooling failure is detected. + If no, the system will not go into idle mode + when a cooling failure is detected. " + ::= { airIRRCUnitConfig 8 } + + +-- airIRRP100 AIR CONDITIONER Group Status + +airIRRP100GroupStatusAirFlowUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group air flow in cubic feet per minute." + ::= { airIRRP100GroupStatus 1 } + +airIRRP100GroupStatusAirFlowMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group air flow in liters per second." + ::= { airIRRP100GroupStatus 2 } + +airIRRP100GroupStatusMaxRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group maximum rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRRP100GroupStatus 3 } + +airIRRP100GroupStatusMaxRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group maximum rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRRP100GroupStatus 4 } + +airIRRP100GroupStatusMinRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group minimum rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRRP100GroupStatus 5 } + +airIRRP100GroupStatusMinRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group minimum rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRRP100GroupStatus 6 } + +airIRRP100GroupStatusCoolDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group coolant demand in tenths of kiloWatts." + ::= { airIRRP100GroupStatus 7 } + +airIRRP100GroupStatusCoolOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group coolant output in tenths of kiloWatts." + ::= { airIRRP100GroupStatus 8 } + +airIRRP100GroupStatusHumidifyDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of humidification the group is demanding + from the humidifiers in percent." + ::= { airIRRP100GroupStatus 9 } + +airIRRP100GroupStatusHumidifyOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual amount of humidification the group is + supplying in percent." + ::= { airIRRP100GroupStatus 10 } + +airIRRP100GroupStatusDehumidifyDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of dehumidification the group is demanding + from the electric heaters in percent." + ::= { airIRRP100GroupStatus 11 } + +airIRRP100GroupStatusDehumidifyOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual amount of dehumidification the group is + supplying in percent." + ::= { airIRRP100GroupStatus 12 } + +airIRRP100GroupStatusReheatDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of heating the group is demanding + from the electric heaters in percent." + ::= { airIRRP100GroupStatus 13 } + +airIRRP100GroupStatusReheatOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual amount of heating the group is + supplying in percent." + ::= { airIRRP100GroupStatus 14 } + + +-- airIRRP100 AIR CONDITIONER Group Setpoints + +airIRRP100GroupSetpointsCoolUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling setpoint in tenths of + degrees Fahrenheit." + ::= { airIRRP100GroupSetpoints 1 } + +airIRRP100GroupSetpointsCoolMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling setpoint in tenths of + degrees Celsius." + ::= { airIRRP100GroupSetpoints 2 } + +airIRRP100GroupSetpointsSupplyAirUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Fahrenheit." + ::= { airIRRP100GroupSetpoints 3 } + +airIRRP100GroupSetpointsSupplyAirMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Celsius." + ::= { airIRRP100GroupSetpoints 4 } + +airIRRP100GroupSetpointsHumidify OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group humidify setpoint in tenths of + percent relative humidity." + ::= { airIRRP100GroupSetpoints 5 } + +airIRRP100GroupSetpointsDehumidify OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group dehumidify setpoint in tenths of + percent relative humidity." + ::= { airIRRP100GroupSetpoints 6 } + +airIRRP100GroupSetpointsDehumidifyDeadband OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group dehumidify deadband in percent relative humidity." + ::= { airIRRP100GroupSetpoints 7 } + +airIRRP100GroupSetpointsReheatUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Fahrenheit." + ::= { airIRRP100GroupSetpoints 8 } + +airIRRP100GroupSetpointsReheatMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Celsius." + ::= { airIRRP100GroupSetpoints 9 } + +airIRRP100GroupSetpointsFanSpeedPreference OBJECT-TYPE + SYNTAX INTEGER { + low (1), + med-low (2), + med (3), + med-high (4), + high (5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The preferred fan speed setting." + ::= { airIRRP100GroupSetpoints 10 } + +airIRRP100GroupSetpointsFanSpeedControl OBJECT-TYPE + SYNTAX INTEGER { + automatic (1), + manual (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The fan speed control setting." + ::= { airIRRP100GroupSetpoints 11 } + + +-- airIRRP100 AIR CONDITIONER Group Config + +airIRRP100GroupConfigNumberofCoolingUnits OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of cooling units present in the group." + ::= { airIRRP100GroupConfig 1 } + +airIRRP100GroupConfigConfigurationType OBJECT-TYPE + SYNTAX INTEGER { + racs (1), + hacs (2), + in-row (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group configuration type." + ::= { airIRRP100GroupConfig 2 } + +airIRRP100GroupConfigCoolGainP OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The gain component of the cool PID in hundredths." + ::= { airIRRP100GroupConfig 3 } + +airIRRP100GroupConfigCoolResetRateI OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The integral component of the cool PID in hundredths." + ::= { airIRRP100GroupConfig 4 } + +airIRRP100GroupConfigCoolDerivativeD OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The derivative component of the cool PID in hundredths." + ::= { airIRRP100GroupConfig 5 } + +airIRRP100GroupConfigHumidifySensitivityBand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The percent relative humidity below the setpoint that + will cause the humidifier to run at 100% capacity." + ::= { airIRRP100GroupConfig 6 } + +airIRRP100GroupConfigReheatGainP OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The gain component of the reheat PID in hundredths." + ::= { airIRRP100GroupConfig 7 } + +airIRRP100GroupConfigReheatResetRateI OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The integral component of the reheat PID in hundredths." + ::= { airIRRP100GroupConfig 8 } + +airIRRP100GroupConfigReheatDerivativeD OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The derivative component of the reheat PID in hundredths." + ::= { airIRRP100GroupConfig 9 } + +airIRRP100GroupConfigNumberofBackupUnits OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of backup units." + ::= { airIRRP100GroupConfig 10 } + +airIRRP100GroupConfigRuntimeBalancingEnable OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable runtime balancing feature." + ::= { airIRRP100GroupConfig 11 } + +airIRRP100GroupConfigLoadAssistEnable OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable load assist feature." + ::= { airIRRP100GroupConfig 12 } + +airIRRP100GroupConfigFullRPBackups OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of full featured RPs that can be used as backup units." + ::= { airIRRP100GroupConfig 13 } + +airIRRP100GroupConfigMaxFanSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum desired fan speed setting in percent." + ::= { airIRRP100GroupConfig 14 } + + +-- airIRRP100 AIR CONDITIONER UNIT Status + +airIRRP100UnitStatusOperateMode OBJECT-TYPE + SYNTAX INTEGER { + standby (1), + on (2), + idle (3), + prestart (4), + service (5), + backup (6), + assist (7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The cooling unit operating mode." + ::= { airIRRP100UnitStatus 1 } + +airIRRP100UnitStatusRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRRP100UnitStatus 2 } + +airIRRP100UnitStatusRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRRP100UnitStatus 3 } + +airIRRP100UnitStatusSupplyAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit supply air temperature in tenths of + degrees Fahrenheit." + ::= { airIRRP100UnitStatus 4 } + +airIRRP100UnitStatusSupplyAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit supply air temperature in tenths of + degrees Celsius." + ::= { airIRRP100UnitStatus 5 } + +airIRRP100UnitStatusReturnAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit return air temperature in tenths of + degrees Fahrenheit." + ::= { airIRRP100UnitStatus 6 } + +airIRRP100UnitStatusReturnAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit return air temperature in tenths of + degrees Celsius." + ::= { airIRRP100UnitStatus 7 } + +airIRRP100UnitStatusSupplyHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The relative humidity of the supply air in + tenths of percent." + ::= { airIRRP100UnitStatus 8 } + +airIRRP100UnitStatusReturnHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The relative humidity of the return air in + tenths of percent." + ::= { airIRRP100UnitStatus 9 } + +airIRRP100UnitStatusAirFlowUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air flow in cubic feet per minute." + ::= { airIRRP100UnitStatus 10 } + +airIRRP100UnitStatusAirFlowMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air flow in hundredths of + liters per second." + ::= { airIRRP100UnitStatus 11 } + +airIRRP100UnitStatusFanSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit average fan speed in tenths of percent." + ::= { airIRRP100UnitStatus 12 } + +airIRRP100UnitStatusCoolDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit cooling demand in tenths of kiloWatts." + ::= { airIRRP100UnitStatus 13 } + +airIRRP100UnitStatusCoolOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit cooling output in tenths of kiloWatts." + ::= { airIRRP100UnitStatus 14 } + +airIRRP100UnitStatusHumidifyDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of humidification the unit is demanding + from the humidifier in percent." + ::= { airIRRP100UnitStatus 15 } + +airIRRP100UnitStatusHumidifyOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual humidification output of the unit + in percent." + ::= { airIRRP100UnitStatus 16 } + +airIRRP100UnitStatusDehumidifyDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of dehumidification the unit is + demanding in percent." + ::= { airIRRP100UnitStatus 17 } + +airIRRP100UnitStatusDehumidifyOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual dehumidification output of the unit + in percent." + ::= { airIRRP100UnitStatus 18 } + +airIRRP100UnitStatusReheatDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of heating the unit is demanding + from the electric heater in percent." + ::= { airIRRP100UnitStatus 19 } + +airIRRP100UnitStatusReheatOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual heating output of the unit + in percent." + ::= { airIRRP100UnitStatus 20 } + +airIRRP100UnitStatusInputState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the input contact." + ::= { airIRRP100UnitStatus 21 } + +airIRRP100UnitStatusOutputState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the output relay." + ::= { airIRRP100UnitStatus 22 } + +airIRRP100UnitStatusRackInletTemperature1US OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature sensor in tenths of + degrees Fahrenheit." + ::= { airIRRP100UnitStatus 23 } + +airIRRP100UnitStatusRackInletTemperature1Metric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature sensor in tenths of + degrees Celsius." + ::= { airIRRP100UnitStatus 24 } + +airIRRP100UnitStatusRackInletTemperature2US OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature sensor in tenths of + degrees Fahrenheit." + ::= { airIRRP100UnitStatus 25 } + +airIRRP100UnitStatusRackInletTemperature2Metric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature sensor in tenths of + degrees Celsius." + ::= { airIRRP100UnitStatus 26 } + +airIRRP100UnitStatusRackInletTemperature3US OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature sensor in tenths of + degrees Fahrenheit." + ::= { airIRRP100UnitStatus 27 } + +airIRRP100UnitStatusRackInletTemperature3Metric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature sensor in tenths of + degrees Celsius." + ::= { airIRRP100UnitStatus 28 } + +airIRRP100UnitStatusFilterDPUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air filter differential pressure in + hundredths of inches of water." + ::= { airIRRP100UnitStatus 29 } + +airIRRP100UnitStatusFilterDPMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air filter differential pressure in Pa." + ::= { airIRRP100UnitStatus 30 } + +airIRRP100UnitStatusContainmtDPUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit containment differential pressure in + hundredths of inches of water." + ::= { airIRRP100UnitStatus 31 } + +airIRRP100UnitStatusContainmtDPMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit containment differential pressure in Pa." + ::= { airIRRP100UnitStatus 32 } + +airIRRP100UnitStatusHumidifierCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The humidifier current of the unit + in amperes." + ::= { airIRRP100UnitStatus 33 } + +airIRRP100UnitStatusHumidifierWaterConductivity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The water conductivity in the humidifier of the unit + in microSiemens/cm." + ::= { airIRRP100UnitStatus 34 } + +airIRRP100UnitStatusCompressorDriveSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The compressor drive speed in hundredths of Hertz." + ::= { airIRRP100UnitStatus 35 } + +airIRRP100UnitStatusCompressorDrivePower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The compressor drive power consumption in + tenths of kiloWatts." + ::= { airIRRP100UnitStatus 36 } + +airIRRP100UnitStatusCompressorDriveVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The compressor drive voltage consumption in + tenths of volts." + ::= { airIRRP100UnitStatus 37 } + +airIRRP100UnitStatusCompressorDriveCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The compressor drive voltage consumption in + tenths of amperes." + ::= { airIRRP100UnitStatus 38 } + +airIRRP100UnitStatusCompressorDriveDCLinkVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The compressor drive DC link voltage in + tenths of volts." + ::= { airIRRP100UnitStatus 39 } + +airIRRP100UnitStatusCompressorDriveHeatSinkTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the compressor drive heatsink + in tenths of degrees Fahrenheit." + ::= { airIRRP100UnitStatus 40 } + +airIRRP100UnitStatusCompressorDriveHeatSinkTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the compressor drive heatsink + in tenths of degrees Celsius." + ::= { airIRRP100UnitStatus 41 } + +airIRRP100UnitStatusCompressorDriveControlCardTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the compressor drive control card + in tenths of degrees Fahrenheit." + ::= { airIRRP100UnitStatus 42 } + +airIRRP100UnitStatusCompressorDriveControlCardTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the compressor drive control card + in tenths of degrees Celsius." + ::= { airIRRP100UnitStatus 43 } + +airIRRP100UnitStatusCompressorDriveWarningStatus OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The four byte warning status of the compressor drive + in hexadecimal." + ::= { airIRRP100UnitStatus 44 } + +airIRRP100UnitStatusCompressorDriveAlarmStatus OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The four byte alarm status of the compressor drive + in hexadecimal." + ::= { airIRRP100UnitStatus 45 } + +airIRRP100UnitStatusSuctionPressureUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit suction pressure in pounds per square inch (PSI)." + ::= { airIRRP100UnitStatus 46 } + +airIRRP100UnitStatusSuctionPressureMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit suction pressure in kiloPascals (kPa)." + ::= { airIRRP100UnitStatus 47 } + +airIRRP100UnitStatusDischargePressureUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit discharge pressure in pounds per square inch (PSI)." + ::= { airIRRP100UnitStatus 48 } + +airIRRP100UnitStatusDischargePressureMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit discharge pressure in kiloPascals (kPa)." + ::= { airIRRP100UnitStatus 49 } + + +-- airIRRP100 AIR CONDITIONER UNIT Ident + +airIRRP100UnitIdentID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The unit identification number." + ::= { airIRRP100UnitIdent 1 } + +airIRRP100UnitIdentName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit name." + ::= { airIRRP100UnitIdent 2 } + +airIRRP100UnitIdentLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit location." + ::= { airIRRP100UnitIdent 3 } + +airIRRP100UnitIdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit model number." + ::= { airIRRP100UnitIdent 4 } + +airIRRP100UnitIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit serial number." + ::= { airIRRP100UnitIdent 5 } + +airIRRP100UnitIdentFirmwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit firmware version." + ::= { airIRRP100UnitIdent 6 } + +airIRRP100UnitIdentHardwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit controller hardware revision." + ::= { airIRRP100UnitIdent 7 } + +airIRRP100UnitIdentManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit manufacture date." + ::= { airIRRP100UnitIdent 8 } + + +-- airIRRP100 AIR CONDITIONER UNIT Runhours + +airIRRP100UnitRunHoursAirFilter OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit air filter run hours." + ::= { airIRRP100UnitRunHours 1 } + +airIRRP100UnitRunHoursCondensatePump OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit condensate pump run hours." + ::= { airIRRP100UnitRunHours 2 } + +airIRRP100UnitRunHoursHumidifier OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan right power supply run hours." + ::= { airIRRP100UnitRunHours 3 } + +airIRRP100UnitRunHoursFan1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan 1 run hours." + ::= { airIRRP100UnitRunHours 4 } + +airIRRP100UnitRunHoursHeater1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit heater 1 run hours." + ::= { airIRRP100UnitRunHours 5 } + +airIRRP100UnitRunHoursFan2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan 2 run hours." + ::= { airIRRP100UnitRunHours 6 } + +airIRRP100UnitRunHoursHeater2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit Heater 2 run hours." + ::= { airIRRP100UnitRunHours 7 } + +airIRRP100UnitRunHoursCompressor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit compressor run hours." + ::= { airIRRP100UnitRunHours 8 } + +airIRRP100UnitRunHoursSystem OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Total system run hours." + ::= { airIRRP100UnitRunHours 9 } + + +-- airIRRP100 AIR CONDITIONER UNIT Service Intervals + +airIRRP100UnitServiceIntervalAirFilter OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Air filter service interval in weeks." + ::= { airIRRP100UnitServiceIntervals 1 } + +airIRRP100UnitServiceIntervalAirFilterAlarm OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The air filter service interval alarm enable/disable." + ::= { airIRRP100UnitServiceIntervals 2 } + +airIRRP100UnitServiceIntervalHumidifier OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Humidifier service interval in weeks." + ::= { airIRRP100UnitServiceIntervals 3 } + +airIRRP100UnitServiceIntervalHumidifierAlarm OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The humidifier service interval alarm enable/disable." + ::= { airIRRP100UnitServiceIntervals 4 } + +airIRRP100UnitServiceIntervalHeater OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Heater service interval in weeks." + ::= { airIRRP100UnitServiceIntervals 5 } + +airIRRP100UnitServiceIntervalHeaterAlarm OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The heater service interval alarm enable/disable." + ::= { airIRRP100UnitServiceIntervals 6 } + +airIRRP100UnitServiceIntervalCompressor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor service interval in weeks." + ::= { airIRRP100UnitServiceIntervals 7 } + +airIRRP100UnitServiceIntervalCompressorAlarm OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The compressor service interval alarm enable/disable." + ::= { airIRRP100UnitServiceIntervals 8 } + +airIRRP100UnitServiceIntervalCondensatePump OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Condensate pump service interval in weeks." + ::= { airIRRP100UnitServiceIntervals 9 } + +airIRRP100UnitServiceIntervalCondensatePumpAlarm OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The condensate pump service interval alarm enable/disable." + ::= { airIRRP100UnitServiceIntervals 10 } + +airIRRP100UnitServiceIntervalFans OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Fans service interval in weeks." + ::= { airIRRP100UnitServiceIntervals 11 } + +airIRRP100UnitServiceIntervalFansAlarm OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The fans service interval alarm enable/disable." + ::= { airIRRP100UnitServiceIntervals 12 } + + + +-- airIRRP100 AIR CONDITIONER UNIT Thresholds + +airIRRP100UnitThresholdsRackInletHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit rack inlet air high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRRP100UnitThresholds 1 } + +airIRRP100UnitThresholdsRackInletHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit rack inlet air high temperature threshold in + tenths of degrees Celsius." + ::= { airIRRP100UnitThresholds 2 } + +airIRRP100UnitThresholdsSupplyAirHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply air high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRRP100UnitThresholds 3 } + +airIRRP100UnitThresholdsSupplyAirHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply air high temperature threshold in + tenths of degrees Celsius." + ::= { airIRRP100UnitThresholds 4 } + +airIRRP100UnitThresholdsReturnAirHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit return air high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRRP100UnitThresholds 5 } + +airIRRP100UnitThresholdsReturnAirHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit return air high temperature threshold in + tenths of degrees Celsius." + ::= { airIRRP100UnitThresholds 6 } + +airIRRP100UnitThresholdsSupplyHumidityHigh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply humidity high threshold in + tenths of percent relative humidity." + ::= { airIRRP100UnitThresholds 7 } + +airIRRP100UnitThresholdsSupplyHumidityLow OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply humidity low threshold in + tenths of percent relative humidity." + ::= { airIRRP100UnitThresholds 8 } + + +-- airIRRP100 AIR CONDITIONER UNIT Config + +airIRRP100UnitConfigStartupDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The startup delay in seconds." + ::= { airIRRP100UnitConfig 1 } + +airIRRP100UnitConfigCoolCapacity OBJECT-TYPE + SYNTAX INTEGER { + automatic (1), + maximum (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The cooling capacity options setting." + ::= { airIRRP100UnitConfig 2 } + +airIRRP100UnitConfigIdleOnLeakDetect OBJECT-TYPE + SYNTAX INTEGER { + yes (1), + no (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The idle on leak options setting." + ::= { airIRRP100UnitConfig 3 } + +airIRRP100UnitConfigInputNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal state of the input contact." + ::= { airIRRP100UnitConfig 4 } + +airIRRP100UnitConfigOutputNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal state of the output relay." + ::= { airIRRP100UnitConfig 5 } + +airIRRP100UnitConfigOutputSource OBJECT-TYPE + SYNTAX INTEGER { + anyAlarm (1), + criticalAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The source of output relay change." + ::= { airIRRP100UnitConfig 6 } + +airIRRP100UnitConfigHumidifyEnable OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable humidification." + ::= { airIRRP100UnitConfig 7 } + +airIRRP100UnitConfigHumidifierControl OBJECT-TYPE + SYNTAX INTEGER { + auto (1), + drainOff (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The humidifier drain control." + ::= { airIRRP100UnitConfig 8 } + +airIRRP100UnitConfigDehumidifyEnable OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable dehumidification." + ::= { airIRRP100UnitConfig 9 } + +airIRRP100UnitConfigReheatEnable OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable reheat." + ::= { airIRRP100UnitConfig 10 } + +airIRRP100UnitConfigHeatAssistEnable OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable heat assist." + ::= { airIRRP100UnitConfig 11 } + +airIRRP100UnitConfigPowerSourceConfig OBJECT-TYPE + SYNTAX INTEGER { + single (1), + dual (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure the input power source: (1) single feed or (2) dual feed." + ::= { airIRRP100UnitConfig 12 } + +airIRRP100UnitConfigUnitRoleOverride OBJECT-TYPE + SYNTAX INTEGER { + automatic (1), + forcedOn (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When this OID value is (1) automatic, the system determines + which units are used as primary units and which units are used as backups. + When this OID value is (2) forcedOn, the connected unit is set as a primary + unit." + ::= { airIRRP100UnitConfig 13 } + + +-- airIRRP500 AIR CONDITIONER Group Status + +airIRRP500GroupStatusAirFlowUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group air flow in cubic feet per minute." + ::= { airIRRP500GroupStatus 1 } + +airIRRP500GroupStatusAirFlowMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group air flow in liters per second." + ::= { airIRRP500GroupStatus 2 } + +airIRRP500GroupStatusMaxRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group maximum rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRRP500GroupStatus 3 } + +airIRRP500GroupStatusMaxRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group maximum rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRRP500GroupStatus 4 } + +airIRRP500GroupStatusMinRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group minimum rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRRP500GroupStatus 5 } + +airIRRP500GroupStatusMinRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group minimum rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRRP500GroupStatus 6 } + +airIRRP500GroupStatusCoolDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group coolant demand in tenths of kiloWatts." + ::= { airIRRP500GroupStatus 7 } + +airIRRP500GroupStatusCoolOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Group coolant output in tenths of kiloWatts." + ::= { airIRRP500GroupStatus 8 } + +airIRRP500GroupStatusHumidifyDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of humidification the group is demanding + from the humidifiers in percent." + ::= { airIRRP500GroupStatus 9 } + +airIRRP500GroupStatusHumidifyOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual amount of humidification the group is + supplying in percent." + ::= { airIRRP500GroupStatus 10 } + +airIRRP500GroupStatusDehumidifyDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of dehumidification the group is demanding + from the electric heaters in percent." + ::= { airIRRP500GroupStatus 11 } + +airIRRP500GroupStatusDehumidifyOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual amount of dehumidification the group is + supplying in percent." + ::= { airIRRP500GroupStatus 12 } + +airIRRP500GroupStatusReheatDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of heating the group is demanding + from the electric heaters in percent." + ::= { airIRRP500GroupStatus 13 } + +airIRRP500GroupStatusReheatOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual amount of heating the group is + supplying in percent." + ::= { airIRRP500GroupStatus 14 } + + +-- airIRRP500 AIR CONDITIONER Group Setpoints + +airIRRP500GroupSetpointsCoolUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling setpoint in tenths of + degrees Fahrenheit." + ::= { airIRRP500GroupSetpoints 1 } + +airIRRP500GroupSetpointsCoolMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling setpoint in tenths of + degrees Celsius." + ::= { airIRRP500GroupSetpoints 2 } + +airIRRP500GroupSetpointsSupplyAirUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Fahrenheit." + ::= { airIRRP500GroupSetpoints 3 } + +airIRRP500GroupSetpointsSupplyAirMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Celsius." + ::= { airIRRP500GroupSetpoints 4 } + +airIRRP500GroupSetpointsHumidify OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group humidify setpoint in tenths of + percent relative humidity." + ::= { airIRRP500GroupSetpoints 5 } + +airIRRP500GroupSetpointsDehumidify OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group dehumidify setpoint in tenths of + percent relative humidity." + ::= { airIRRP500GroupSetpoints 6 } + +airIRRP500GroupSetpointsDehumidifyDeadband OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group dehumidify deadband in + percent relative humidity." + ::= { airIRRP500GroupSetpoints 7 } + +airIRRP500GroupSetpointsReheatUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Fahrenheit." + ::= { airIRRP500GroupSetpoints 8 } + +airIRRP500GroupSetpointsReheatMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Celsius." + ::= { airIRRP500GroupSetpoints 9 } + +airIRRP500GroupSetpointsFanSpeedPreference OBJECT-TYPE + SYNTAX INTEGER { + low (1), + med-low (2), + med (3), + med-high (4), + high (5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The preferred fan speed setting." + ::= { airIRRP500GroupSetpoints 10 } + +airIRRP500GroupSetpointsFanSpeedControl OBJECT-TYPE + SYNTAX INTEGER { + automatic (1), + manual (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The fan speed control setting." + ::= { airIRRP500GroupSetpoints 11 } + + +-- airIRRP500 AIR CONDITIONER Group Config + +airIRRP500GroupConfigNumberofCoolingUnits OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of cooling units." + ::= { airIRRP500GroupConfig 1 } + +airIRRP500GroupConfigConfigurationType OBJECT-TYPE + SYNTAX INTEGER { + racs (1), + hacs (2), + in-row (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group configuration type." + ::= { airIRRP500GroupConfig 2 } + +airIRRP500GroupConfigPercentGlycol OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The glycol mixture in percent." + ::= { airIRRP500GroupConfig 3 } + +airIRRP500GroupConfigCoolGainP OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The gain component of the cool PID in hundredths." + ::= { airIRRP500GroupConfig 4 } + +airIRRP500GroupConfigCoolResetRateI OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The integral component of the cool PID in hundredths." + ::= { airIRRP500GroupConfig 5 } + +airIRRP500GroupConfigCoolDerivativeD OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The derivative component of the cool PID in hundredths." + ::= { airIRRP500GroupConfig 6 } + +airIRRP500GroupConfigHumidifySensitivityBand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The percent relative humidity below the setpoint that + will cause the humidifier to run at 100% capacity." + ::= { airIRRP500GroupConfig 7 } + +airIRRP500GroupConfigReheatGainP OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The gain component of the reheat PID in hundredths." + ::= { airIRRP500GroupConfig 8 } + +airIRRP500GroupConfigReheatResetRateI OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The integral component of the reheat PID in hundredths." + ::= { airIRRP500GroupConfig 9 } + +airIRRP500GroupConfigReheatDerivativeD OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The derivative component of the reheat PID in hundredths." + ::= { airIRRP500GroupConfig 10 } + +airIRRP500GroupConfigMaxFanSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum desired fan speed setting in percent." + ::= { airIRRP500GroupConfig 11 } + +airIRRP500GroupConfigNumberofBackupUnits OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of backup units." + ::= { airIRRP500GroupConfig 12 } + +airIRRP500GroupConfigRuntimeBalancingEnable OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable runtime balancing feature." + ::= { airIRRP500GroupConfig 13 } + +airIRRP500GroupConfigLoadAssistEnable OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable load assist feature." + ::= { airIRRP500GroupConfig 14 } + +airIRRP500GroupConfigFullRPBackups OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of full featured RPs that can be used as backup units." + ::= { airIRRP500GroupConfig 15 } + + +-- airIRRP500 AIR CONDITIONER UNIT Status + +airIRRP500UnitStatusOperateMode OBJECT-TYPE + SYNTAX INTEGER { + standby (1), + on (2), + idle (3), + prestart (4), + backup (5), + assist (6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The cooling unit operating mode." + ::= { airIRRP500UnitStatus 1 } + +airIRRP500UnitStatusMaximumRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum unit rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRRP500UnitStatus 2 } + +airIRRP500UnitStatusMaximumRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum unit rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRRP500UnitStatus 3 } + +airIRRP500UnitStatusSupplyAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit supply air temperature in tenths of + degrees Fahrenheit." + ::= { airIRRP500UnitStatus 4 } + +airIRRP500UnitStatusSupplyAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit supply air temperature in tenths of + degrees Celsius." + ::= { airIRRP500UnitStatus 5 } + +airIRRP500UnitStatusReturnAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit return air temperature in tenths of + degrees Fahrenheit." + ::= { airIRRP500UnitStatus 6 } + +airIRRP500UnitStatusReturnAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit return air temperature in tenths of + degrees Celsius." + ::= { airIRRP500UnitStatus 7 } + +airIRRP500UnitStatusSupplyHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The relative humidity of the supply air in + tenths of percent." + ::= { airIRRP500UnitStatus 8 } + +airIRRP500UnitStatusReturnHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The relative humidity of the return air in + tenths of percent." + ::= { airIRRP500UnitStatus 9 } + +airIRRP500UnitStatusAirFlowUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air flow in cubic feet per minute." + ::= { airIRRP500UnitStatus 10 } + +airIRRP500UnitStatusAirFlowMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air flow in hundredths of + liters per second." + ::= { airIRRP500UnitStatus 11 } + +airIRRP500UnitStatusFanSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit average fan speed in tenths of percent." + ::= { airIRRP500UnitStatus 12 } + +airIRRP500UnitStatusCoolDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit cooling demand in tenths of kiloWatts." + ::= { airIRRP500UnitStatus 13 } + +airIRRP500UnitStatusCoolOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit cooling output in tenths of kiloWatts." + ::= { airIRRP500UnitStatus 14 } + +airIRRP500UnitStatusHumidifyDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of humidification the unit is demanding + from the humidifier in percent." + ::= { airIRRP500UnitStatus 15 } + +airIRRP500UnitStatusHumidifyOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual humidification output of the unit + in percent." + ::= { airIRRP500UnitStatus 16 } + +airIRRP500UnitStatusDehumidifyDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of dehumidification the unit is + demanding in percent." + ::= { airIRRP500UnitStatus 17 } + +airIRRP500UnitStatusDehumidifyOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual dehumidification output of the unit + in percent." + ::= { airIRRP500UnitStatus 18 } + +airIRRP500UnitStatusReheatDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of heating the unit is demanding + from the electric heater in percent." + ::= { airIRRP500UnitStatus 19 } + +airIRRP500UnitStatusReheatOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual heating output of the unit + in percent." + ::= { airIRRP500UnitStatus 20 } + +airIRRP500UnitStatusInputState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the input contact." + ::= { airIRRP500UnitStatus 21 } + +airIRRP500UnitStatusOutputState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the output relay." + ::= { airIRRP500UnitStatus 22 } + +airIRRP500UnitStatusRackInletTemperature1US OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature sensor in tenths of + degrees Fahrenheit." + ::= { airIRRP500UnitStatus 23 } + +airIRRP500UnitStatusRackInletTemperature1Metric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature sensor in tenths of + degrees Celsius." + ::= { airIRRP500UnitStatus 24 } + +airIRRP500UnitStatusRackInletTemperature2US OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature sensor in tenths of + degrees Fahrenheit." + ::= { airIRRP500UnitStatus 25 } + +airIRRP500UnitStatusRackInletTemperature2Metric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature sensor in tenths of + degrees Celsius." + ::= { airIRRP500UnitStatus 26 } + +airIRRP500UnitStatusRackInletTemperature3US OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature sensor in tenths of + degrees Fahrenheit." + ::= { airIRRP500UnitStatus 27 } + +airIRRP500UnitStatusRackInletTemperature3Metric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature sensor in tenths of + degrees Celsius." + ::= { airIRRP500UnitStatus 28 } + +airIRRP500UnitStatusContainmtDPUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit containment differential pressure in + hundredths of inches of water." + ::= { airIRRP500UnitStatus 29 } + +airIRRP500UnitStatusContainmtDPMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit containment differential pressure in Pa." + ::= { airIRRP500UnitStatus 30 } + +airIRRP500UnitStatusFilterDPUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air filter differential pressure in + hundredths of inches of water." + ::= { airIRRP500UnitStatus 31 } + +airIRRP500UnitStatusFilterDPMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air filter differential pressure in Pa." + ::= { airIRRP500UnitStatus 32 } + +airIRRP500UnitStatusHumidifierCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The humidifier current of the unit + in amperes." + ::= { airIRRP500UnitStatus 33 } + +airIRRP500UnitStatusHumidifierWaterConductivity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The water conductivity in the humidifier of the unit + in microSiemens/cm." + ::= { airIRRP500UnitStatus 34 } + +airIRRP500UnitStatusActivePowerSource OBJECT-TYPE + SYNTAX INTEGER { + sourceA (1), + sourceB (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The power source that is powering the unit." + ::= { airIRRP500UnitStatus 35 } + +airIRRP500UnitStatusFluidValvePosition OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The fluid valve position in percent open." + ::= { airIRRP500UnitStatus 36 } + +airIRRP500UnitStatusFluidFlowUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The fluid flow in tenths of gallons per minute." + ::= { airIRRP500UnitStatus 37 } + +airIRRP500UnitStatusFluidFlowMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The fluid flow in hundredths of liters per second." + ::= { airIRRP500UnitStatus 38 } + +airIRRP500UnitStatusEnteringFluidTemperatureUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the entering fluid in + tenths of degrees Fahrenheit." + ::= { airIRRP500UnitStatus 39 } + +airIRRP500UnitStatusEnteringFluidTemperatureMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the entering fluid in + tenths of degrees Celsius." + ::= { airIRRP500UnitStatus 40 } + +airIRRP500UnitStatusLeavingFluidTemperatureUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the Leaving fluid in + tenths of degrees Fahrenheit." + ::= { airIRRP500UnitStatus 41 } + +airIRRP500UnitStatusLeavingFluidTemperatureMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of the Leaving fluid in + tenths of degrees Celsius." + ::= { airIRRP500UnitStatus 42 } + + + +-- airIRRP500 AIR CONDITIONER UNIT Ident + +airIRRP500UnitIdentID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The unit identification number." + ::= { airIRRP500UnitIdent 1 } + +airIRRP500UnitIdentName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit name." + ::= { airIRRP500UnitIdent 2 } + +airIRRP500UnitIdentLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit location." + ::= { airIRRP500UnitIdent 3 } + +airIRRP500UnitIdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit model number." + ::= { airIRRP500UnitIdent 4 } + +airIRRP500UnitIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit serial number." + ::= { airIRRP500UnitIdent 5 } + +airIRRP500UnitIdentFirmwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit firmware version." + ::= { airIRRP500UnitIdent 6 } + +airIRRP500UnitIdentHardwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit controller hardware revision." + ::= { airIRRP500UnitIdent 7 } + +airIRRP500UnitIdentManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit manufacture date." + ::= { airIRRP500UnitIdent 8 } + + +-- airIRRP500 AIR CONDITIONER UNIT Runhours + +airIRRP500UnitRunHoursAirFilter OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit air filter run hours in hours." + ::= { airIRRP500UnitRunHours 1 } + +airIRRP500UnitRunHoursCondensatePump OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit condensate pump run hours in hours." + ::= { airIRRP500UnitRunHours 2 } + +airIRRP500UnitRunHoursHumidifier OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan right power supply run hours in hours." + ::= { airIRRP500UnitRunHours 3 } + +airIRRP500UnitRunHoursFan1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan 1 run hours in hours." + ::= { airIRRP500UnitRunHours 4 } + +airIRRP500UnitRunHoursHeater1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit heater 1 run hours in hours." + ::= { airIRRP500UnitRunHours 5 } + +airIRRP500UnitRunHoursFan2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan 2 run hours in hours." + ::= { airIRRP500UnitRunHours 6 } + +airIRRP500UnitRunHoursHeater2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit Heater 2 run hours in hours." + ::= { airIRRP500UnitRunHours 7 } + +airIRRP500UnitRunHoursFan3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan 3 run hours in hours." + ::= { airIRRP500UnitRunHours 8 } + +airIRRP500UnitRunHoursHeater3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit heater 3 run hours in hours." + ::= { airIRRP500UnitRunHours 9 } + +airIRRP500UnitRunHoursSystem OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Total system run hours." + ::= { airIRRP500UnitRunHours 10 } + + +-- airIRRP500 AIR CONDITIONER UNIT Service Intervals + +airIRRP500UnitServiceIntervalAirFilter OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Air filter service interval in weeks." + ::= { airIRRP500UnitServiceIntervals 1 } + +airIRRP500UnitServiceIntervalAirFilterAlarm OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The air filter service interval alarm enable/disable." + ::= { airIRRP500UnitServiceIntervals 2 } + +airIRRP500UnitServiceIntervalHumidifier OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Humidifier service interval in weeks." + ::= { airIRRP500UnitServiceIntervals 3 } + +airIRRP500UnitServiceIntervalHumidifierAlarm OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The humidifier service interval alarm enable/disable." + ::= { airIRRP500UnitServiceIntervals 4 } + +airIRRP500UnitServiceIntervalHeater OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Heater service interval in weeks." + ::= { airIRRP500UnitServiceIntervals 5 } + +airIRRP500UnitServiceIntervalHeaterAlarm OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The heater service interval alarm enable/disable." + ::= { airIRRP500UnitServiceIntervals 6 } + +airIRRP500UnitServiceIntervalCondensatePump OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Condensate pump service interval in weeks." + ::= { airIRRP500UnitServiceIntervals 7 } + +airIRRP500UnitServiceIntervalCondensatePumpAlarm OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The condensate pump service interval alarm enable/disable." + ::= { airIRRP500UnitServiceIntervals 8 } + +airIRRP500UnitServiceIntervalFans OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Fans service interval in weeks." + ::= { airIRRP500UnitServiceIntervals 9 } + +airIRRP500UnitServiceIntervalFansAlarm OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The fans service interval alarm enable/disable." + ::= { airIRRP500UnitServiceIntervals 10 } + + +-- airIRRP500 AIR CONDITIONER UNIT Thresholds + +airIRRP500UnitThresholdsRackInletHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit rack inlet air high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRRP500UnitThresholds 1 } + +airIRRP500UnitThresholdsRackInletHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit rack inlet air high temperature threshold in + tenths of degrees Celsius." + ::= { airIRRP500UnitThresholds 2 } + +airIRRP500UnitThresholdsSupplyAirHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply air temperature high threshold in + tenths of degrees Fahrenheit." + ::= { airIRRP500UnitThresholds 3 } + +airIRRP500UnitThresholdsSupplyAirHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply air high temperature high threshold in + tenths of degrees Celsius." + ::= { airIRRP500UnitThresholds 4 } + +airIRRP500UnitThresholdsReturnAirHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit return air high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRRP500UnitThresholds 5 } + +airIRRP500UnitThresholdsReturnAirHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit return air high temperature threshold in + tenths of degrees Celsius." + ::= { airIRRP500UnitThresholds 6 } + +airIRRP500UnitThresholdsSupplyHumidityHigh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply humidity high threshold in + tenths of percent relative humidity." + ::= { airIRRP500UnitThresholds 7 } + +airIRRP500UnitThresholdsSupplyHumidityLow OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply humidity low threshold in + tenths of percent relative humidity." + ::= { airIRRP500UnitThresholds 8 } + +airIRRP500UnitThresholdsEnteringFluidHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Entering fluid high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRRP500UnitThresholds 9 } + +airIRRP500UnitThresholdsEnteringFluidHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Entering fluid high temperature threshold in + tenths of degrees Celsius." + ::= { airIRRP500UnitThresholds 10 } + + +-- airIRRP500 AIR CONDITIONER UNIT Config + +airIRRP500UnitConfigStartupDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The startup delay in seconds." + ::= { airIRRP500UnitConfig 1 } + +airIRRP500UnitConfigCoolCapacity OBJECT-TYPE + SYNTAX INTEGER { + automatic (1), + maximum (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The cooling capacity options setting." + ::= { airIRRP500UnitConfig 2 } + +airIRRP500UnitConfigIdleOnLeakDetect OBJECT-TYPE + SYNTAX INTEGER { + yes (1), + no (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The idle on leak options setting." + ::= { airIRRP500UnitConfig 3 } + +airIRRP500UnitConfigInputNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal state of the input contact." + ::= { airIRRP500UnitConfig 4 } + +airIRRP500UnitConfigOutputNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal state of the output relay." + ::= { airIRRP500UnitConfig 5 } + +airIRRP500UnitConfigOutputSource OBJECT-TYPE + SYNTAX INTEGER { + anyAlarm (1), + criticalAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The source of output relay change." + ::= { airIRRP500UnitConfig 6 } + +airIRRP500UnitConfigHumidifyEnable OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable humidification." + ::= { airIRRP500UnitConfig 7 } + +airIRRP500UnitConfigHumidifierControl OBJECT-TYPE + SYNTAX INTEGER { + auto (1), + drainOff (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The humidifier drain control." + ::= { airIRRP500UnitConfig 8 } + +airIRRP500UnitConfigDehumidifyEnable OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable dehumidification." + ::= { airIRRP500UnitConfig 9 } + +airIRRP500UnitConfigReheatEnable OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable reheat." + ::= { airIRRP500UnitConfig 10 } + +airIRRP500UnitConfigHeatAssistEnable OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable heat assist." + ::= { airIRRP500UnitConfig 11 } + +airIRRP500UnitConfigPowerSourceConfig OBJECT-TYPE + SYNTAX INTEGER { + single (1), + dual (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Configure the input power source: (1) single feed or (2) dual feed." + ::= { airIRRP500UnitConfig 12 } + +airIRRP500UnitConfigUnitRoleOverride OBJECT-TYPE + SYNTAX INTEGER { + automatic (1), + forcedOn (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When this OID value is (1) automatic, the system determines + which units are used as primary units and which units are used as backups. + When this OID value is (2) forcedOn, the connected unit is set as a primary + unit." + ::= { airIRRP500UnitConfig 13 } + + +-- airIRSC AIR CONDITIONER Defines + +AirIRSCConfigType ::= INTEGER { + racs (1), + spot (2), + in-row (3) + } + +AirIRSCCapacityControlType ::= INTEGER { + discrete (1), + proportional (2) + } + +AirIRSCFanSpeedPreference ::= INTEGER { + low (1), + med-low (2), + med (3), + med-high (4), + high (5) + } + +AirIRSCFanSpeedControl ::= INTEGER { + automatic (1), + manual (2) + } + +-- airIRSC AIR CONDITIONER UNIT Status + +airIRSCUnitStatusOperateMode OBJECT-TYPE + SYNTAX INTEGER { + standby (1), + on (2), + idle (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The cooling unit operating mode." + ::= { airIRSCUnitStatus 1 } + +airIRSCUnitStatusCoolOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit cooling output in tenths of kW." + ::= { airIRSCUnitStatus 2 } + +airIRSCUnitStatusCoolDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit cooling demand in tenths of kW." + ::= { airIRSCUnitStatus 3 } + +airIRSCUnitStatusAirFlowUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air flow in cubic feet per minute." + ::= { airIRSCUnitStatus 4 } + +airIRSCUnitStatusAirFlowMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air flow in liters per second." + ::= { airIRSCUnitStatus 5 } + +airIRSCUnitStatusRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRSCUnitStatus 6 } + +airIRSCUnitStatusRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRSCUnitStatus 7 } + +airIRSCUnitStatusSupplyAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit supply air temperature in tenths of + degrees Fahrenheit." + ::= { airIRSCUnitStatus 8 } + +airIRSCUnitStatusSupplyAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit supply air temperature in tenths of + degrees Celsius." + ::= { airIRSCUnitStatus 9 } + +airIRSCUnitStatusReturnAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit return air temperature in tenths of + degrees Fahrenheit." + ::= { airIRSCUnitStatus 10 } + +airIRSCUnitStatusReturnAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit return air temperature in tenths of + degrees Celsius." + ::= { airIRSCUnitStatus 11 } + +airIRSCUnitStatusSuctionTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit suction temperature in tenths of + degrees Fahrenheit." + ::= { airIRSCUnitStatus 12 } + +airIRSCUnitStatusSuctionTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit suction temperature in tenths of + degrees Celsius." + ::= { airIRSCUnitStatus 13 } + +airIRSCUnitStatusSuperheatTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit superheat temperature in tenths of + degrees Fahrenheit." + ::= { airIRSCUnitStatus 14 } + +airIRSCUnitStatusSuperheatTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit superheat temperature in tenths of + degrees Celsius." + ::= { airIRSCUnitStatus 15 } + +airIRSCUnitStatusContainmtDPUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit containment differential pressure in + hundredths of inches of water." + ::= { airIRSCUnitStatus 16 } + +airIRSCUnitStatusContainmtDPMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit containment differential pressure in Pa." + ::= { airIRSCUnitStatus 17 } + +airIRSCUnitStatusFilterDPUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air filter differential pressure in + hundredths of inches of water." + ::= { airIRSCUnitStatus 18 } + +airIRSCUnitStatusFilterDPMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air filter differential pressure in Pa." + ::= { airIRSCUnitStatus 19 } + +airIRSCUnitStatusSuctionPressureUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit suction pressure in pounds per square inch (PSI)." + ::= { airIRSCUnitStatus 20 } + +airIRSCUnitStatusSuctionPressureMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit suction pressure in kiloPascals (kPa)." + ::= { airIRSCUnitStatus 21 } + +airIRSCUnitStatusDischargePressureUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit discharge pressure in pounds per square inch (PSI)." + ::= { airIRSCUnitStatus 22 } + +airIRSCUnitStatusDischargePressureMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit discharge pressure in kiloPascals (kPa)." + ::= { airIRSCUnitStatus 23 } + +airIRSCUnitStatusEvaporatorFanSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit average evaporator fan speed in tenths of percent." + ::= { airIRSCUnitStatus 24 } + +airIRSCUnitStatusCondenserFanSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit average condenser fan speed in tenths of percent." + ::= { airIRSCUnitStatus 25 } + +airIRSCUnitStatusInputState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the input contact." + ::= { airIRSCUnitStatus 26 } + +airIRSCUnitStatusOutputState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the output relay." + ::= { airIRSCUnitStatus 27 } + +airIRSCUnitStatusCondOutletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit condenser outlet air temperature in tenths of + degrees Fahrenheit." + ::= { airIRSCUnitStatus 28 } + +airIRSCUnitStatusCondOutletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit condenser outlet air temperature in tenths of + degrees Celsius." + ::= { airIRSCUnitStatus 29 } + +airIRSCUnitStatusCondInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit condenser inlet air temperature in tenths of + degrees Fahrenheit." + ::= { airIRSCUnitStatus 30 } + +airIRSCUnitStatusCondInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit condenser inlet air temperature in tenths of + degrees Celsius." + ::= { airIRSCUnitStatus 31 } + +airIRSCUnitStatusCompressor OBJECT-TYPE + SYNTAX INTEGER { + off (1), + on (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state (off/on) of the compressor." + ::= { airIRSCUnitStatus 32 } + + +-- airIRSC AIR CONDITIONER UNIT Ident + +airIRSCUnitIdentName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit name." + ::= { airIRSCUnitIdent 1 } + +airIRSCUnitIdentLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit location." + ::= { airIRSCUnitIdent 2 } + +airIRSCUnitIdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit model number." + ::= { airIRSCUnitIdent 3 } + +airIRSCUnitIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit serial number." + ::= { airIRSCUnitIdent 4 } + +airIRSCUnitIdentFirmwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit firmware version." + ::= { airIRSCUnitIdent 5 } + +airIRSCUnitIdentHardwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit controller hardware revision." + ::= { airIRSCUnitIdent 6 } + +airIRSCUnitIdentManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the + unit manufacture date." + ::= { airIRSCUnitIdent 7 } + + +-- airIRSC AIR CONDITIONER UNIT Runhours + +airIRSCUnitRunHoursAirFilter OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit air filter run hours." + ::= { airIRSCUnitRunHours 1 } + +airIRSCUnitRunHoursEvaporatorFan1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit evaporator fan 1 run hours." + ::= { airIRSCUnitRunHours 2 } + +airIRSCUnitRunHoursEvaporatorFan2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit evaporator fan 2 run hours." + ::= { airIRSCUnitRunHours 3 } + +airIRSCUnitRunHoursEvaporatorFan3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit evaporator fan 3 run hours." + ::= { airIRSCUnitRunHours 4 } + +airIRSCUnitRunHoursCondenserFan1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit condenser fan 1 run hours." + ::= { airIRSCUnitRunHours 5 } + +airIRSCUnitRunHoursCondenserFan2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit condenser fan 2 run hours." + ::= { airIRSCUnitRunHours 6 } + +airIRSCUnitRunHoursCondenserFan3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit condenser fan 3 run hours." + ::= { airIRSCUnitRunHours 7 } + +airIRSCUnitRunHoursFanPowerSupplyLeft OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan left power supply run hours." + ::= { airIRSCUnitRunHours 8 } + +airIRSCUnitRunHoursFanPowerSupplyRight OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit fan right power supply run hours." + ::= { airIRSCUnitRunHours 9 } + +airIRSCUnitRunHoursCondensatePump OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit condensate pump run hours." + ::= { airIRSCUnitRunHours 10 } + +airIRSCUnitRunHoursCompressor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit compressor run hours." + ::= { airIRSCUnitRunHours 11 } + + +-- airIRSC AIR CONDITIONER UNIT Service Intervals + +airIRSCUnitServiceIntervalsAirFilter OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Air filter service interval in weeks." + ::= { airIRSCUnitServiceIntervals 1 } + +airIRSCUnitServiceIntervalsAirFilterAlarm OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The air filter service interval alarm enable/disable." + ::= { airIRSCUnitServiceIntervals 2 } + + +-- airIRSC AIR CONDITIONER UNIT Thresholds + +airIRSCUnitThresholdsRackInletHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit rack inlet air high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRSCUnitThresholds 1 } + +airIRSCUnitThresholdsRackInletHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit rack inlet air high temperature threshold in + tenths of degrees Celsius." + ::= { airIRSCUnitThresholds 2 } + +airIRSCUnitThresholdsSupplyAirHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply air high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRSCUnitThresholds 3 } + +airIRSCUnitThresholdsSupplyAirHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply air high temperature threshold in + tenths of degrees Celsius." + ::= { airIRSCUnitThresholds 4 } + +airIRSCUnitThresholdsReturnAirHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit return air high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRSCUnitThresholds 5 } + +airIRSCUnitThresholdsReturnAirHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit return air high temperature threshold in + tenths of degrees Celsius." + ::= { airIRSCUnitThresholds 6 } + +-- airIRSC AIR CONDITIONER UNIT Setpoints + +airIRSCUnitSetptsCoolSetpointUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit cooling setpoint in tenths of + degrees Fahrenheit." + ::= { airIRSCUnitSetpoints 1 } + +airIRSCUnitSetptsCoolSetpointMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit cooling setpoint in tenths of + degrees Celsius." + ::= { airIRSCUnitSetpoints 2 } + +airIRSCUnitSetptsCoolDeadbandUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit cooling deadband in tenths of + degrees Fahrenheit." + ::= { airIRSCUnitSetpoints 3 } + +airIRSCUnitSetptsCoolDeadbandMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit cooling deadband in tenths of + degrees Celsius." + ::= { airIRSCUnitSetpoints 4 } + +airIRSCUnitSetptsFanSpeedPreference OBJECT-TYPE + SYNTAX AirIRSCFanSpeedPreference + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The preferred fan speed setting." + ::= { airIRSCUnitSetpoints 5 } + +airIRSCUnitSetptsSupplyAirSetpointUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply air setpoint in tenths of + degrees Fahrenheit." + ::= { airIRSCUnitSetpoints 6 } + +airIRSCUnitSetptsSupplyAirSetpointMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply air setpoint in tenths of + degrees Celsius." + ::= { airIRSCUnitSetpoints 7 } + +-- airIRSC AIR CONDITIONER UNIT Config + +airIRSCUnitConfigConfigurationType OBJECT-TYPE + SYNTAX AirIRSCConfigType + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The unit configuration type." + ::= { airIRSCUnitConfig 1 } + +airIRSCUnitConfigCapacityControlType OBJECT-TYPE + SYNTAX AirIRSCCapacityControlType + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The unit capacity control." + ::= { airIRSCUnitConfig 2 } + +airIRSCUnitConfigStartupDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The startup delay in seconds." + ::= { airIRSCUnitConfig 3 } + +airIRSCUnitConfigIdleOnLeakDetect OBJECT-TYPE + SYNTAX INTEGER { + yes (1), + no (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The idle on leak options setting." + ::= { airIRSCUnitConfig 4 } + +airIRSCUnitConfigInputNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal state of the input contact." + ::= { airIRSCUnitConfig 5 } + +airIRSCUnitConfigOutputNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal state of the output relay." + ::= { airIRSCUnitConfig 6 } + +airIRSCUnitConfigOutputSource OBJECT-TYPE + SYNTAX INTEGER { + anyAlarm (1), + criticalAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The source of output relay change." + ::= { airIRSCUnitConfig 7 } + +airIRSCUnitConfigAltitudeUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The altitude of the unit above sea level in feet." + ::= { airIRSCUnitConfig 8 } + +airIRSCUnitConfigAltitudeMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The altitude of the unit above sea level in meters." + ::= { airIRSCUnitConfig 9 } + +airIRSCUnitConfigOpControl OBJECT-TYPE + SYNTAX INTEGER { + standby (1), + on (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The unit operational control." + ::= { airIRSCUnitConfig 10 } + + +-- airIRSC AIR CONDITIONER GROUP Status + +airIRSCGroupStatusCoolOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group cooling output in tenths of kW." + ::= { airIRSCGroupStatus 1 } + +airIRSCGroupStatusCoolDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group cooling demand in tenths of kW." + ::= { airIRSCGroupStatus 2 } + +airIRSCGroupStatusAirFlowUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group air flow in cubic feet per minute." + ::= { airIRSCGroupStatus 3 } + +airIRSCGroupStatusAirFlowMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group air flow in liters per second." + ::= { airIRSCGroupStatus 4 } + +airIRSCGroupStatusMaxRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group maximum rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRSCGroupStatus 5 } + +airIRSCGroupStatusMaxRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group maximum rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRSCGroupStatus 6 } + +airIRSCGroupStatusMinRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group minimum rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRSCGroupStatus 7 } + +airIRSCGroupStatusMinRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group minimum rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRSCGroupStatus 8 } + +airIRSCGroupStatusMaxReturnAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group maximum return air temperature in tenths of + degrees Fahrenheit." + ::= { airIRSCGroupStatus 9 } + +airIRSCGroupStatusMaxReturnAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group maximum return air temperature in tenths of + degrees Celsius." + ::= { airIRSCGroupStatus 10 } + +airIRSCGroupStatusMinReturnAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group minimum return air temperature in tenths of + degrees Fahrenheit." + ::= { airIRSCGroupStatus 11 } + +airIRSCGroupStatusMinReturnAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group minimum return air temperature in tenths of + degrees Celsius." + ::= { airIRSCGroupStatus 12 } + + +-- airIRSC AIR CONDITIONER GROUP Setpoint + +airIRSCGroupSetptsCoolSetpointUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling setpoint in tenths of + degrees Fahrenheit." + ::= { airIRSCGroupSetpoints 1 } + +airIRSCGroupSetptsCoolSetpointMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling setpoint in tenths of + degrees Celsius." + ::= { airIRSCGroupSetpoints 2 } + +airIRSCGroupSetptsCoolDeadbandUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling deadband in tenths of + degrees Fahrenheit." + ::= { airIRSCGroupSetpoints 3 } + +airIRSCGroupSetptsCoolDeadbandMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling deadband in tenths of + degrees Celsius." + ::= { airIRSCGroupSetpoints 4 } + +airIRSCGroupSetptsFanSpeedPreference OBJECT-TYPE + SYNTAX AirIRSCFanSpeedPreference + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group preferred fan speed setting." + ::= { airIRSCGroupSetpoints 5 } + +airIRSCGroupSetptsSupplyAirSetpointUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Fahrenheit." + ::= { airIRSCGroupSetpoints 6 } + +airIRSCGroupSetptsSupplyAirSetpointMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Celsius." + ::= { airIRSCGroupSetpoints 7 } + + +-- airIRSC AIR CONDITIONER GROUP Config + +airIRSCGroupConfigNumberofCoolingUnits OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of cooling units." + ::= { airIRSCGroupConfig 1 } + +airIRSCGroupConfigConfigurationType OBJECT-TYPE + SYNTAX AirIRSCConfigType + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group configuration type." + ::= { airIRSCGroupConfig 2 } + +airIRSCGroupConfigCapacityControlType OBJECT-TYPE + SYNTAX AirIRSCCapacityControlType + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group capacity control." + ::= { airIRSCGroupConfig 3 } + +airIRSCGroupConfigAltitudeUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group altitude of the units above sea level in feet." + ::= { airIRSCGroupConfig 4 } + +airIRSCGroupConfigAltitudeMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group altitude of the units above sea level in meters." + ::= { airIRSCGroupConfig 5 } + +airIRSCGroupConfigFanSpeedControl OBJECT-TYPE + SYNTAX AirIRSCFanSpeedControl + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group fan speed control." + ::= { airIRSCGroupConfig 6 } + + +-- ****************************************************************** +-- airIRG2 Ident +-- ****************************************************************** + +airIRG2IdentName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the unit name." + ::= { airIRG2Ident 1 } + +airIRG2IdentLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the unit location." + ::= { airIRG2Ident 2 } + +airIRG2IdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the unit model number." + ::= { airIRG2Ident 3 } + +airIRG2IdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the unit serial number." + ::= { airIRG2Ident 4 } + +airIRG2IdentFirmwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the unit firmware version." + ::= { airIRG2Ident 5 } + +airIRG2IdentHardwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the unit controller hardware revision." + ::= { airIRG2Ident 6 } + +airIRG2IdentManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the unit manufacture date." + ::= { airIRG2Ident 7 } + +airIRG2IdentUnitSysOID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID contains an OID path to the device's top level unit data." + ::= { airIRG2Ident 8 } + +airIRG2IdentGroupSysOID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID contains an OID path to the device's top level group data." + ::= { airIRG2Ident 9 } + +-- ****************************************************************** +-- airIRG2 GROUP Status +-- ****************************************************************** + +airIRG2GroupStatusCoolOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group cooling output in tenths of kilowatts (kW)." + ::= { airIRG2GroupStatus 1 } + +airIRG2GroupStatusCoolDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group cooling demand in tenths of kilowatts (kW)." + ::= { airIRG2GroupStatus 2 } + +airIRG2GroupStatusAirFlowUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group air flow in cubic feet per minute." + ::= { airIRG2GroupStatus 3 } + +airIRG2GroupStatusAirFlowMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group air flow in hundredths of + liters per second." + ::= { airIRG2GroupStatus 4 } + +airIRG2GroupStatusMaxRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group maximum rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRG2GroupStatus 5 } + +airIRG2GroupStatusMaxRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group maximum rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRG2GroupStatus 6 } + +airIRG2GroupStatusMinRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group minimum rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRG2GroupStatus 7 } + +airIRG2GroupStatusMinRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group minimum rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRG2GroupStatus 8 } + +airIRG2GroupStatusMaxReturnAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group maximum return air temperature in tenths of + degrees Fahrenheit." + ::= { airIRG2GroupStatus 9 } + +airIRG2GroupStatusMaxReturnAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group maximum return air temperature in tenths of + degrees Celsius." + ::= { airIRG2GroupStatus 10 } + +airIRG2GroupStatusMinReturnAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group minimum return air temperature in tenths of + degrees Fahrenheit." + ::= { airIRG2GroupStatus 11 } + +airIRG2GroupStatusMinReturnAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group minimum return air temperature in tenths of + degrees Celsius." + ::= { airIRG2GroupStatus 12 } + + +-- ****************************************************************** +-- airIRG2 GROUP Setpoint +-- ****************************************************************** + +airIRG2GroupSetptsCoolSetpointUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling setpoint in tenths of + degrees Fahrenheit." + ::= { airIRG2GroupSetpoints 1 } + +airIRG2GroupSetptsCoolSetpointMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling setpoint in tenths of + degrees Celsius." + ::= { airIRG2GroupSetpoints 2 } + +airIRG2GroupSetptsCoolDeadbandUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling deadband in tenths of + degrees Fahrenheit." + ::= { airIRG2GroupSetpoints 3 } + +airIRG2GroupSetptsCoolDeadbandMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling deadband in tenths of + degrees Celsius." + ::= { airIRG2GroupSetpoints 4 } + +airIRG2GroupSetptsFanSpeedPreference OBJECT-TYPE + SYNTAX INTEGER { + low (1), + med-low (2), + med (3), + med-high (4), + high (5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group preferred fan speed setting." + ::= { airIRG2GroupSetpoints 5 } + +airIRG2GroupSetptsSupplyAirSetpointUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Fahrenheit." + ::= { airIRG2GroupSetpoints 6 } + +airIRG2GroupSetptsSupplyAirSetpointMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Celsius." + ::= { airIRG2GroupSetpoints 7 } + + +-- ****************************************************************** +-- airIRG2 GROUP Config +-- ****************************************************************** +airIRG2GroupConfigNumberofCoolingUnits OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of cooling units." + ::= { airIRG2GroupConfig 1 } + +airIRG2GroupConfigConfigurationType OBJECT-TYPE + SYNTAX INTEGER { + racs (1), + spot (2), + in-row (3), + hacs (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group configuration type." + ::= { airIRG2GroupConfig 2 } + +airIRG2GroupConfigCapacityControlType OBJECT-TYPE + SYNTAX INTEGER { + discrete (1), + proportional (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group capacity control." + ::= { airIRG2GroupConfig 3 } + +airIRG2GroupConfigFanSpeedControl OBJECT-TYPE + SYNTAX INTEGER { + automatic (1), + manual (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group fan speed control." + ::= { airIRG2GroupConfig 4 } + +airIRG2GroupConfigCoolGainP OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The gain component of the PID in hundredths." + ::= { airIRG2GroupConfig 5 } + +airIRG2GroupConfigCoolResetRateI OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The integral component of the PID in hundredths." + ::= { airIRG2GroupConfig 6 } + +airIRG2GroupConfigCoolDerivativeD OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The derivative component of the PID in hundredths." + ::= { airIRG2GroupConfig 7 } + +airIRG2GroupConfigCoolPIDReset OBJECT-TYPE + SYNTAX INTEGER { + readBack (1), + reset (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Will reset the PID coefficients back to the factory defaults." + ::= { airIRG2GroupConfig 8 } + +airIRG2GroupConfigNumberofBackupUnits OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of backup units." + ::= { airIRG2GroupConfig 9 } + +airIRG2GroupConfigRuntimeBalancingEnable OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable runtime balancing feature." + ::= { airIRG2GroupConfig 10 } + +airIRG2GroupConfigLoadAssistEnable OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable load assist feature." + ::= { airIRG2GroupConfig 11 } + + +-- *************************************** +-- airIRG2 Alarm Status +-- *************************************** + +airIRG2AlarmsTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of active alarms in the airIRG2AlarmsTable." + ::= { airIRG2Alarms 1 } + +AirIRG2AlarmsEntry ::= SEQUENCE { + airIRG2AlarmsIndex INTEGER, + airIRG2AlarmsEventCode INTEGER, + airIRG2AlarmsDescription DisplayString + } + +airIRG2AlarmsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG2AlarmsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Table of active alarms for the device." + ::= { airIRG2Alarms 2 } + +airIRG2AlarmsEntry OBJECT-TYPE + SYNTAX AirIRG2AlarmsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Alarms specification" + INDEX { airIRG2AlarmsIndex } + ::= { airIRG2AlarmsTable 1 } + +airIRG2AlarmsIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Alarm index." + ::= { airIRG2AlarmsEntry 1 } + +airIRG2AlarmsEventCode OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Code for the alarm." + ::= { airIRG2AlarmsEntry 2 } + +airIRG2AlarmsDescription OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..64)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of the alarm." + ::= { airIRG2AlarmsEntry 3 } + +-- *************************************** +-- airIRG2RDType2 AIR CONDITIONER Defines +-- *************************************** + +AirIRG2RDType2IOState ::= INTEGER { + open (1), + closed (2) +} + +-- ****************************************************************** +-- airIRG2RDT2 Status +-- ****************************************************************** + +airIRG2RDT2StatusOperateMode OBJECT-TYPE + SYNTAX INTEGER { + standby (1), + on (2), + idle (3), + reserved (4), + service (5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The cooling unit operating mode." + ::= { airIRG2RDT2Status 1 } + +airIRG2RDT2StatusCoolOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit cooling output in tenths of kilowatts (kW)." + ::= { airIRG2RDT2Status 2 } + +airIRG2RDT2StatusCoolDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit cooling demand in tenths of kilowatts (kW)." + ::= { airIRG2RDT2Status 3 } + +airIRG2RDT2StatusAirFlowUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air flow in cubic feet per minute." + ::= { airIRG2RDT2Status 4 } + +airIRG2RDT2StatusAirFlowMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air flow in liters per second." + ::= { airIRG2RDT2Status 5 } + +airIRG2RDT2StatusRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRG2RDT2Status 6 } + +airIRG2RDT2StatusRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRG2RDT2Status 7 } + +airIRG2RDT2StatusSupplyAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit supply air temperature in tenths of + degrees Fahrenheit." + ::= { airIRG2RDT2Status 8 } + +airIRG2RDT2StatusSupplyAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit supply air temperature in tenths of + degrees Celsius." + ::= { airIRG2RDT2Status 9 } + +airIRG2RDT2StatusReturnAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit return air temperature in tenths of + degrees Fahrenheit." + ::= { airIRG2RDT2Status 10 } + +airIRG2RDT2StatusReturnAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit return air temperature in tenths of + degrees Celsius." + ::= { airIRG2RDT2Status 11 } + +airIRG2RDT2StatusSuctionTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit suction temperature in tenths of + degrees Fahrenheit." + ::= { airIRG2RDT2Status 12 } + +airIRG2RDT2StatusSuctionTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit suction temperature in tenths of + degrees Celsius." + ::= { airIRG2RDT2Status 13 } + +airIRG2RDT2StatusSuperheatTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit superheat temperature in tenths of + degrees Fahrenheit." + ::= { airIRG2RDT2Status 14 } + +airIRG2RDT2StatusSuperheatTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit superheat temperature in tenths of + degrees Celsius." + ::= { airIRG2RDT2Status 15 } + +airIRG2RDT2StatusFilterDPUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air filter differential pressure in + hundredths of inches of water." + ::= { airIRG2RDT2Status 16 } + +airIRG2RDT2StatusFilterDPMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit air filter differential pressure in pascals (Pa)." + ::= { airIRG2RDT2Status 17 } + +airIRG2RDT2StatusSuctionPressureUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit suction pressure in pounds per square inch (PSI)." + ::= { airIRG2RDT2Status 18 } + +airIRG2RDT2StatusSuctionPressureMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit suction pressure in kiloPascals (kPa)." + ::= { airIRG2RDT2Status 19 } + +airIRG2RDT2StatusDischargePressureUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit discharge pressure in pounds per square inch (PSI)." + ::= { airIRG2RDT2Status 20 } + +airIRG2RDT2StatusDischargePressureMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit discharge pressure in kiloPascals (kPa)." + ::= { airIRG2RDT2Status 21 } + +airIRG2RDT2StatusEvaporatorFanSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unit average evaporator fan speed in tenths of percent." + ::= { airIRG2RDT2Status 22 } + +airIRG2RDT2StatusInputState OBJECT-TYPE + SYNTAX AirIRG2RDType2IOState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the input contact." + ::= { airIRG2RDT2Status 23 } + +airIRG2RDT2StatusOutputState OBJECT-TYPE + SYNTAX AirIRG2RDType2IOState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the output relay." + ::= { airIRG2RDT2Status 24 } + +airIRG2RDT2StatusOHEInputState OBJECT-TYPE + SYNTAX AirIRG2RDType2IOState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the outside heat exchanger(OHE) input contact." + ::= { airIRG2RDT2Status 25 } + +airIRG2RDT2StatusOHEOutputState OBJECT-TYPE + SYNTAX AirIRG2RDType2IOState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the outside heat exchanger(OHE) output relay." + ::= { airIRG2RDT2Status 26 } + +airIRG2RDT2StatusCompressor OBJECT-TYPE + SYNTAX INTEGER { + off (1), + on (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state (off/on) of the compressor." + ::= { airIRG2RDT2Status 27 } + +airIRG2RDT2StatusFluidValvePos OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The position of the fluid valve in percent. This OID is only valid + when airIRG2RDT2ConfigUnitType indicates fluidCooled(1)." + ::= { airIRG2RDT2Status 28 } + +airIRG2RDT2StatusHotGasBypassValvePos OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The position of the hot gas bypass valve in hundredths of percent." + ::= { airIRG2RDT2Status 29 } + + +-- ****************************************************************** +-- airIRG2RDT2 Runhours +-- ****************************************************************** + +airIRG2RDT2RunHoursAirFilter OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit air filter run hours." + ::= { airIRG2RDT2RunHours 1 } + +airIRG2RDT2RunHoursCondensatePump OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit condensate pump run hours." + ::= { airIRG2RDT2RunHours 2 } + +airIRG2RDT2RunHoursCompressor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit compressor run hours." + ::= { airIRG2RDT2RunHours 3 } + +-- ******************************* +-- Run Hour Fan Power supply table +-- ******************************* +airIRG2RDT2RunHoursFanPSTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the run hour fan power supply table + (airIRG2RDT2RunHoursFanPSTable)." + ::= { airIRG2RDT2RunHours 4 } + +AirIRG2RDT2RunHoursFanPSEntry ::= + SEQUENCE { + airIRG2RDT2RunHoursFanPSIndex INTEGER, + airIRG2RDT2RunHoursFanPSPosition INTEGER, + airIRG2RDT2RunHoursFanPSHours INTEGER + } + +airIRG2RDT2RunHoursFanPSTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG2RDT2RunHoursFanPSEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting run hour information from each power supply." + ::= { airIRG2RDT2RunHours 5 } + +airIRG2RDT2RunHoursFanPSEntry OBJECT-TYPE + SYNTAX AirIRG2RDT2RunHoursFanPSEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The run hours fan power supply table entry." + INDEX { airIRG2RDT2RunHoursFanPSIndex } + ::= { airIRG2RDT2RunHoursFanPSTable 1 } + +airIRG2RDT2RunHoursFanPSIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of run hours fan power supply table." + ::= { airIRG2RDT2RunHoursFanPSEntry 1 } + +airIRG2RDT2RunHoursFanPSHours OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan power supply run time in hours." + ::= { airIRG2RDT2RunHoursFanPSEntry 2 } + +airIRG2RDT2RunHoursFanPSPosition OBJECT-TYPE + SYNTAX INTEGER { + upper (1), + lower (2), + left (3), + right (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Position of fan power supply within the unit." + ::= { airIRG2RDT2RunHoursFanPSEntry 3 } + +-- ***************************** +-- Run Hour Evaporator Fan table +-- ***************************** +airIRG2RDT2RunHoursEvapFanTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the run hour evaporator fan table + (airIRG2RDT2RunHoursEvapFanTable)." + ::= { airIRG2RDT2RunHours 6 } + +AirIRG2RDT2RunHoursEvapFanEntry ::= + SEQUENCE { + airIRG2RDT2RunHoursEvapFanIndex INTEGER, + airIRG2RDT2RunHoursEvapFanHours INTEGER + } + +airIRG2RDT2RunHoursEvapFanTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG2RDT2RunHoursEvapFanEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each evaporator fan run + hour in the system. " + ::= { airIRG2RDT2RunHours 7 } + +airIRG2RDT2RunHoursEvapFanEntry OBJECT-TYPE + SYNTAX AirIRG2RDT2RunHoursEvapFanEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information from each evaporator fan run + hour in the system. " + INDEX { airIRG2RDT2RunHoursEvapFanIndex } + ::= { airIRG2RDT2RunHoursEvapFanTable 1 } + +airIRG2RDT2RunHoursEvapFanIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of run hours evaporator fan table." + ::= { airIRG2RDT2RunHoursEvapFanEntry 1 } + +airIRG2RDT2RunHoursEvapFanHours OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Evaporator fan run time in hours." + ::= { airIRG2RDT2RunHoursEvapFanEntry 2 } + +airIRG2RDT2RunHoursUnit OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit run time in hours." + ::= { airIRG2RDT2RunHours 8 } + +-- ****************************************************************** +-- airIRG2RDT2 Service Intervals +-- ****************************************************************** + +airIRG2RDT2ServiceIntervalsAirFilter OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Air filter service interval in weeks." + ::= { airIRG2RDT2ServiceIntervals 1 } + +airIRG2RDT2ServiceIntervalsAirFilterAlarm OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The air filter service interval alarm enable/disable." + ::= { airIRG2RDT2ServiceIntervals 2 } + +-- ****************************************************************** +-- airIRG2RDT2 Thresholds +-- ****************************************************************** + +airIRG2RDT2ThresholdsRackInletHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit rack inlet air high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRG2RDT2Thresholds 1 } + +airIRG2RDT2ThresholdsRackInletHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit rack inlet air high temperature threshold in + tenths of degrees Celsius." + ::= { airIRG2RDT2Thresholds 2 } + +airIRG2RDT2ThresholdsSupplyAirHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply air high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRG2RDT2Thresholds 3 } + +airIRG2RDT2ThresholdsSupplyAirHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit supply air high temperature threshold in + tenths of degrees Celsius." + ::= { airIRG2RDT2Thresholds 4 } + +airIRG2RDT2ThresholdsReturnAirHighTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit return air high temperature threshold in + tenths of degrees Fahrenheit." + ::= { airIRG2RDT2Thresholds 5 } + +airIRG2RDT2ThresholdsReturnAirHighTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Unit return air high temperature threshold in + tenths of degrees Celsius." + ::= { airIRG2RDT2Thresholds 6 } + +-- ****************************************************************** +-- airIRG2RDT2 Setpoints +-- ****************************************************************** + +-- There are no setpoint OIDs. This is just a placeholder in case +-- we add some unit setpoints. + +-- ****************************************************************** +-- airIRG2RDT2 Config +-- ****************************************************************** + +airIRG2RDT2ConfigUnitType OBJECT-TYPE + SYNTAX INTEGER { + fluidCooled (1), + airCooled (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of the unit." + ::= { airIRG2RDT2Config 1 } + +airIRG2RDT2ConfigStartupDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The startup delay in seconds." + ::= { airIRG2RDT2Config 2 } + +airIRG2RDT2ConfigIdleOnLeakDetect OBJECT-TYPE + SYNTAX INTEGER { + yes (1), + no (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The idle on leak options setting." + ::= { airIRG2RDT2Config 3 } + +airIRG2RDT2ConfigInputNormalState OBJECT-TYPE + SYNTAX AirIRG2RDType2IOState + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal state of the input contact." + ::= { airIRG2RDT2Config 4 } + +airIRG2RDT2ConfigOutputNormalState OBJECT-TYPE + SYNTAX AirIRG2RDType2IOState + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal state of the output relay." + ::= { airIRG2RDT2Config 5 } + +airIRG2RDT2ConfigOutputSource OBJECT-TYPE + SYNTAX INTEGER { + anyAlarm (1), + criticalAlarm (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The source of output relay change." + ::= { airIRG2RDT2Config 6 } + +airIRG2RDT2ConfigOHEInputNormalState OBJECT-TYPE + SYNTAX AirIRG2RDType2IOState + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The normal state of the outside heat exchanger(OHE) input relay." + ::= { airIRG2RDT2Config 7 } + +airIRG2RDT2ConfigUnitRoleOverride OBJECT-TYPE + SYNTAX INTEGER { + automatic (1), + forcedOn (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When this OID value is (1) automatic, the system determines + which units are used as primary units and which units are used as backups. + When this OID value is (2) forcedOn, the connected unit is set as a primary + unit." + ::= { airIRG2RDT2Config 8 } + +airIRG2RDT2ConfigUnitIdleOnCoolFail OBJECT-TYPE + SYNTAX INTEGER { + no (1), + yes (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When this OID value is (2) yes, the unit idles if it detects that it is blowing warm + air into the cold aisle. The unit will attempt to restart at 5 minute intervals." + ::= { airIRG2RDT2Config 9 } + +-- Beginning of AC InRoom + +-- common InRoom values +AirIRmAlarmState ::= INTEGER { ok (1), alarm (2) } +AirIRmControlState ::= INTEGER { off (1), on (2) } +AirIRmStopState ::= INTEGER { maybeOn (1), unitOff (2) } +AirIRmActivityState ::= INTEGER { inactive (1), active (2) } + + +-- *************************************** +-- InRoom Ident +-- *************************************** + +airIRmIdentName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the unit name." + ::= { airIRmIdent 1 } + +airIRmIdentLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the unit location." + ::= { airIRmIdent 2 } + +airIRmIdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the unit model number." + ::= { airIRmIdent 3 } + +airIRmIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the unit serial number." + ::= { airIRmIdent 4 } + +airIRmIdentFirmwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the unit firmware version." + ::= { airIRmIdent 5 } + +airIRmIdentHardwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the unit controller hardware revision." + ::= { airIRmIdent 6 } + +airIRmIdentManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the unit manufacture date." + ::= { airIRmIdent 7 } + +airIRmIdentSysOID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID contains an OID path to the device's top level data." + ::= { airIRmIdent 8 } + +-- *************************************** +-- InRoom Alarm Status +-- *************************************** + +airIRmAlarmsTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of active alarms in the airIRG2AlarmsTable." + ::= { airIRmAlarms 1 } + +AirIRmAlarmsEntry ::= SEQUENCE { + airIRmAlarmsIndex INTEGER, + airIRmAlarmsEventCode INTEGER, + airIRmAlarmsDescription DisplayString + } + +airIRmAlarmsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRmAlarmsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Table of active alarms for the device." + ::= { airIRmAlarms 2 } + +airIRmAlarmsEntry OBJECT-TYPE + SYNTAX AirIRmAlarmsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Alarms specification" + INDEX { airIRmAlarmsIndex } + ::= { airIRmAlarmsTable 1 } + +airIRmAlarmsIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Alarm index." + ::= { airIRmAlarmsEntry 1 } + +airIRmAlarmsEventCode OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Code for the alarm." + ::= { airIRmAlarmsEntry 2 } + +airIRmAlarmsDescription OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..64)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of the alarm." + ::= { airIRmAlarmsEntry 3 } + + +-- airIRmPmCommon1 + +airIRmPmUnitType OBJECT-TYPE + SYNTAX INTEGER { + mc (1), + dx (2), + cw (3), + ch (4), + ecoCool (5), + msc (6), + ge1 (7), + ge2 (8), + dualFluid (9), + cw2 (10), + unknown (256) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit type (1)." + ::= { airIRmPmCommon1 1 } + +airIRmPmSwVersion OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Software version (3)." + ::= { airIRmPmCommon1 3 } + +airIRmPmBusAddress OBJECT-TYPE + SYNTAX INTEGER (0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Bus addresss of unit (5)." + ::= { airIRmPmCommon1 5 } + +airIRmPmControllerType OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + c4000 (2), + c1001 (3), + c1002 (4), + c5000 (5), + c6000 (6), + c1010 (7), + c7000IOC (8), + c7000AT (9), + c7000PT (10), + c5MSC (11), + c7000PT2 (12) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Controller type (7)." + ::= { airIRmPmCommon1 7 } + +airIRmPmGeneralError OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "General Error (8)" + ::= { airIRmPmCommon1 8 } + +airIRmPmErrorOnBus OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Error On Bus (9)" + ::= { airIRmPmCommon1 9 } + +-- airIRmPmCommon2 + +airIRmPmPCStop OBJECT-TYPE + SYNTAX AirIRmStopState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "PC-STOP (1000)" + ::= { airIRmPmCommon2 1 } + +airIRmPmRemoteStop OBJECT-TYPE + SYNTAX AirIRmStopState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Remote Stop (1001)" + ::= { airIRmPmCommon2 2 } + +airIRmPmLocalStop OBJECT-TYPE + SYNTAX AirIRmStopState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Local Stop (1002)" + ::= { airIRmPmCommon2 3} + +airIRmPmTimerStop OBJECT-TYPE + SYNTAX AirIRmStopState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Timer Stop (1003)" + ::= { airIRmPmCommon2 4} + +airIRmPmSeqStop OBJECT-TYPE + SYNTAX AirIRmStopState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Seq. Stop (1004)" + ::= { airIRmPmCommon2 5} + +airIRmPmRemoteUPS OBJECT-TYPE + SYNTAX INTEGER { + off (1), + on (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Remote UPS (1006)" + ::= { airIRmPmCommon2 7} + +airIRmPmLocalUPS OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Local UPS (1007)" + ::= { airIRmPmCommon2 8} + +airIRmPmCommonAlarm OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Common alarm (1010)." + ::= { airIRmPmCommon2 11 } + +airIRmPmResetAllAlarms OBJECT-TYPE + SYNTAX INTEGER { + doNothing (1), + reset (2) } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset all alarms control (1011)." + ::= { airIRmPmCommon2 12 } + +airIRmPmUnitOnOff OBJECT-TYPE + SYNTAX AirIRmControlState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit running state (1013)." + ::= { airIRmPmCommon2 14 } + +airIRmPmMaintenance OBJECT-TYPE + SYNTAX INTEGER { + notNecessary (1), + necessary (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Maintenance necessary state (1014)." + ::= { airIRmPmCommon2 15 } + +airIRmPmUnitTemperatureScale OBJECT-TYPE + SYNTAX INTEGER { + celsius (1), + fahrenheit (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Current Unit Temperature Scale (1022)." + ::= { airIRmPmCommon2 23 } + +airIRmPmUnitWinterMode OBJECT-TYPE + SYNTAX INTEGER { + summer (1), + winter (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Winter or summer configuration mode (1023)." + ::= { airIRmPmCommon2 24 } + +airIRmPmDayNightMode OBJECT-TYPE + SYNTAX INTEGER { + day (1), + night (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Day or night configuration mode (1024)." + ::= { airIRmPmCommon2 25 } + + +-- airIRmPmCommon3 + +airIRmPmLastMaintenanceYear OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Last maintenance year (1160)." + ::= { airIRmPmCommon3 1 } + +airIRmPmLastMaintenanceMonth OBJECT-TYPE + SYNTAX INTEGER (1..12) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Last maintenance month (1161)." + ::= { airIRmPmCommon3 2 } + +airIRmPmLastMaintenanceDay OBJECT-TYPE + SYNTAX INTEGER (1..31) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Last maintenance day (1162)." + ::= { airIRmPmCommon3 3 } + +airIRmPmUnitMaintenanceInterval OBJECT-TYPE + SYNTAX INTEGER (1..255) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit maintenance interval in months (1163)." + ::= { airIRmPmCommon3 4 } + +airIRmPmRuntimeUnit OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Runtime unit in hours (1164)." + ::= { airIRmPmCommon3 5 } + +airIRmPmStoptimeUnit OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit stoptime in hours (1165)" + ::= { airIRmPmCommon3 6 } + +airIRmPmRuntimeCooling OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Cooling runtime in hours (1166)" + ::= { airIRmPmCommon3 7 } + +airIRmPmRuntimeHeating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Heating runtime in hours (1167)" + ::= { airIRmPmCommon3 8 } + +airIRmPmRuntimeHumidification OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidification runtime in hours (1168)" + ::= { airIRmPmCommon3 9 } + +airIRmPmRuntimeDehumidification OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Dehumidification runtime in hours (1169)" + ::= { airIRmPmCommon3 10 } + +airIRmPmUnitTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon3 11 } +airIRmPmUnitTemperatureC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit temperature in tenths of degrees Celsius (1170)." + ::= { airIRmPmUnitTemperature 1 } +airIRmPmUnitTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit temperature in tenths of degrees Fahrenheit (1170)." + ::= { airIRmPmUnitTemperature 2 } + +airIRmPmUnitHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit humidity in tenths of %RH (1171)." + ::= { airIRmPmCommon3 12 } + +airIRmPmSetpointTemperatureDay OBJECT IDENTIFIER ::= { airIRmPmCommon3 14 } +airIRmPmSetpointTemperatureDayC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setpoint daytime temperature in tenths + of degrees Celsius (1173)." + ::= { airIRmPmSetpointTemperatureDay 1 } +airIRmPmSetpointTemperatureDayF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setpoint daytime temperature in tenths + of degrees Fahrenheit (1173)." + ::= { airIRmPmSetpointTemperatureDay 2 } + +airIRmPmSetpointTemperatureNight OBJECT IDENTIFIER ::= { airIRmPmCommon3 15 } +airIRmPmSetpointTemperatureNightC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setpoint nighttime temperature in tenths + of degrees Celsius (1174)." + ::= { airIRmPmSetpointTemperatureNight 1 } +airIRmPmSetpointTemperatureNightF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setpoint nighttime temperature in tenths + of degrees Fahrenheit (1174)." + ::= { airIRmPmSetpointTemperatureNight 2 } + +airIRmPmSetpointHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setpoint humidity in tenths of %RH (1176)." + ::= { airIRmPmCommon3 17 } + +airIRmPmUnitControlType OBJECT-TYPE + SYNTAX INTEGER { + room (1), + supply (2), + room-SupplyLimit (3), + supply-RoomLimit (4) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Current unit control type (1183)." + ::= { airIRmPmCommon3 24 } + +airIRmPmWinterModeStartTemp OBJECT IDENTIFIER ::= { airIRmPmCommon3 29 } +airIRmPmWinterModeStartTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Winter mode start temperature in tenths of degrees Celsius (1188)." + ::= { airIRmPmWinterModeStartTemp 1 } +airIRmPmWinterModeStartTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Winter mode start temperature in tenths of degrees Fahrenheit (1188)." + ::= { airIRmPmWinterModeStartTemp 2 } + +airIRmPmWinterModeHysteresis OBJECT IDENTIFIER ::= { airIRmPmCommon3 30 } +airIRmPmWinterModeHysteresisK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Winter mode hysteresis in tenths of Kelvins (1189)" + ::= { airIRmPmWinterModeHysteresis 1 } +airIRmPmWinterModeHysteresisF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Winter mode hysteresis in tenths of degrees Fahrenheit (1189)" + ::= { airIRmPmWinterModeHysteresis 2 } + +airIRmPmWaterTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon3 32 } +airIRmPmWaterTemperatureC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Water temperature in tenths of degrees Celsius (1191)." + ::= { airIRmPmWaterTemperature 1 } +airIRmPmWaterTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Water temperature in tenths of degrees Fahrenheit (1191)." + ::= { airIRmPmWaterTemperature 2 } + +airIRmPmReturnAirTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon3 33 } +airIRmPmReturnAirTemperatureC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Return air temperature in tenths of degrees Celsius (1192)." + ::= { airIRmPmReturnAirTemperature 1 } +airIRmPmReturnAirTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Return air temperature in tenths of degrees Fahrenheit (1192)." + ::= { airIRmPmReturnAirTemperature 2 } + +airIRmPmSupplyAirTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon3 34 } +airIRmPmSupplyAirTemperatureC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Supply air temperature in tenths of degrees Celsius (1193)." + ::= { airIRmPmSupplyAirTemperature 1 } +airIRmPmSupplyAirTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Supply air temperature in tenths of degrees Fahrenheit (1193)." + ::= { airIRmPmSupplyAirTemperature 2 } + +airIRmPmReturnAirHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Return air humidity in tenths of %RH (1194)." + ::= { airIRmPmCommon3 35 } + +airIRmPmSupplyAirHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Supply air humidity in tenths of %RH (1195)." + ::= { airIRmPmCommon3 36 } + +airIRmPmOutsideAirTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon3 37 } +airIRmPmOutsideAirTemperatureC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Outside air temperature in tenths of degrees Celsius (1196)" + ::= { airIRmPmOutsideAirTemperature 1 } +airIRmPmOutsideAirTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Outside air temperature in tenths of degrees Fahrenheit (1196)" + ::= { airIRmPmOutsideAirTemperature 2 } + +airIRmPmOutsideAirHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Outside air humidity in tenths of percent relative humidity (1197)" + ::= { airIRmPmCommon3 38 } + +airIRmPmCoolingPriority OBJECT-TYPE + SYNTAX INTEGER { + ge (1), + cw (2), + dx (3) } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Cooling priority (1198)." + ::= { airIRmPmCommon3 39 } + +airIRmPmWaterTemperature2 OBJECT IDENTIFIER ::= { airIRmPmCommon3 43 } +airIRmPmWaterTemperature2C OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Water temperature 2 in tenths of degrees Celsius (1202)." + ::= { airIRmPmWaterTemperature2 1 } +airIRmPmWaterTemperature2F OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Water temperature 2 in tenths of degrees Fahrenheit (1202)." + ::= { airIRmPmWaterTemperature2 2 } + +airIRmPmRuntimeFreeCooling OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Freecooling runtime in hours (1203)" + ::= { airIRmPmCommon3 44 } + +airIRmPmRuntimeMixedModeFreeCooling OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Mixed mode freecooling runtime in hours (1203)" + ::= { airIRmPmCommon3 45 } + +-- airIRmPmCommon4 + +airIRmPmNumberOfCompressors OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of compressors (1761)" + ::= { airIRmPmCommon4 4 } + +airIRmPmNumberOfSuctionValves OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of suction valves (1762)" + ::= { airIRmPmCommon4 5 } + +airIRmPmNumberOfDryCoolers OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of drycoolers (1763)" + ::= { airIRmPmCommon4 6 } + +airIRmPmNumberOfPumps OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of pumps (1764)" + ::= { airIRmPmCommon4 7 } + +airIRmPmNumberOfElectricHeaters OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of electric heaters (1765)" + ::= { airIRmPmCommon4 8 } + +airIRmPmNumberOfHumidifiers OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of humidifiers (1766)" + ::= { airIRmPmCommon4 9 } + +airIRmPmNumberOfFans OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of fans (1767)" + ::= { airIRmPmCommon4 10 } + +airIRmPmNumberOfLouvers OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of louvers (1768)" + ::= { airIRmPmCommon4 11 } + +airIRmPmNumberOfSensors OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of sensors (1769)" + ::= { airIRmPmCommon4 12 } + +airIRmPmNumberOfExternalAlarmInputs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of external alarm inputs (1770)" + ::= { airIRmPmCommon4 13 } + +airIRmPmNumberOfGECWValves OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of GE/CW valves (1771)" + ::= { airIRmPmCommon4 14 } + +airIRmPmNumberOfHotGasReheat OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of hot gas reheaters (1772)" + ::= { airIRmPmCommon4 15 } + +airIRmPmNumberOfPWWReheat OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of PWW reheaters (1773)" + ::= { airIRmPmCommon4 16 } + +airIRmPmNumberOfDehumidifiers OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of dehumidifiers (1774)" + ::= { airIRmPmCommon4 17 } + +-- airIRmPmCommon5 + +airIRmPmUnitEvaporationTemperature1 OBJECT IDENTIFIER ::= { airIRmPmCommon5 1 } +airIRmPmUnitEvaporationTemperature1C OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit evaporation temperature 1 in tenths + of degrees Celsius (2232)" + ::= { airIRmPmUnitEvaporationTemperature1 1 } +airIRmPmUnitEvaporationTemperature1F OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit evaporation temperature 1 in tenths + of degrees Fahrenheit (2232)" + ::= { airIRmPmUnitEvaporationTemperature1 2 } + +airIRmPmUnitEvaporationPressure1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit evaporation pressure 1 in tenths + of Bars (2233)" + ::= { airIRmPmCommon5 2 } + +airIRmPmUnitCondensationTemperature1 OBJECT IDENTIFIER ::= { airIRmPmCommon5 3 } +airIRmPmUnitCondensationTemperature1C OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit condensation temperature 1 in tenths + of degrees Celsius (2234)" + ::= { airIRmPmUnitCondensationTemperature1 1 } +airIRmPmUnitCondensationTemperature1F OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit condensation temperature 1 in tenths + of degrees Fahrenheit (2234)" + ::= { airIRmPmUnitCondensationTemperature1 2 } + +airIRmPmUnitCondensationPressure1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit condensation pressure 1 in tenths + of Bars (2235)" + ::= { airIRmPmCommon5 4 } + +airIRmPmMaxLimitReturnAirTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon5 8 } +airIRmPmMaxLimitReturnAirTemperatureC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum limit return air temperature in tenths + of degrees Celsius (2239)." + ::= { airIRmPmMaxLimitReturnAirTemperature 1 } +airIRmPmMaxLimitReturnAirTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum limit return air temperature in tenths + of degrees Fahrenheit (2239)." + ::= { airIRmPmMaxLimitReturnAirTemperature 2 } + +airIRmPmMinLimitReturnAirTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon5 9 } +airIRmPmMinLimitReturnAirTemperatureC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum limit return air temperature in tenths + of degrees Celsius (2240)." + ::= { airIRmPmMinLimitReturnAirTemperature 1 } +airIRmPmMinLimitReturnAirTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum limit return air temperature in tenths + of degrees Fahrenheit (2240)." + ::= { airIRmPmMinLimitReturnAirTemperature 2 } + +airIRmPmMaxLimitSupplyAirTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon5 10 } +airIRmPmMaxLimitSupplyAirTemperatureC OBJECT-TYPE + SYNTAX INTEGER + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum limit supply air temperature in tenths + of degrees Celsius (2241)." + ::= { airIRmPmMaxLimitSupplyAirTemperature 1 } +airIRmPmMaxLimitSupplyAirTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum limit supply air temperature in tenths + of degrees Fahrenheit (2241)." + ::= { airIRmPmMaxLimitSupplyAirTemperature 2 } + +airIRmPmMinLimitSupplyAirTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon5 11 } +airIRmPmMinLimitSupplyAirTemperatureC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum limit supply air temperature in tenths + of degrees Celsius (2242)." + ::= { airIRmPmMinLimitSupplyAirTemperature 1 } +airIRmPmMinLimitSupplyAirTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum limit supply air temperature in tenths + of degrees Fahrenheit (2242)." + ::= { airIRmPmMinLimitSupplyAirTemperature 2 } + +airIRmPmMaxLimitWaterTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon5 12 } +airIRmPmMaxLimitWaterTemperatureC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum limit water temperature in tenths of degrees Celsius (2243)." + ::= { airIRmPmMaxLimitWaterTemperature 1 } +airIRmPmMaxLimitWaterTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum limit water temperature in tenths + of degrees Fahrenheit (2243)." + ::= { airIRmPmMaxLimitWaterTemperature 2 } + +airIRmPmMinLimitWaterTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon5 13 } +airIRmPmMinLimitWaterTemperatureC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum limit water temperature in tenths + of degrees Celsius (2244)." + ::= { airIRmPmMinLimitWaterTemperature 1 } +airIRmPmMinLimitWaterTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum limit water temperature in tenths + of degrees Fahrenheit (2244)." + ::= { airIRmPmMinLimitWaterTemperature 2 } + +airIRmPmMaxLimitReturnAirHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum limit return air humidity in tenths of %RH (2245)." + ::= { airIRmPmCommon5 14 } + +airIRmPmMinLimitReturnAirHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum limit return air humidity in tenths of %RH (2246)." + ::= { airIRmPmCommon5 15 } + +airIRmPmMaxLimitSupplyAirHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum limit supply air humidity in tenths of %RH (2247)." + ::= { airIRmPmCommon5 16 } + +airIRmPmMinLimitSupplyAirHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum limit supply air humidity in tenths of %RH (2248)." + ::= { airIRmPmCommon5 17 } + +airIRmPmLowPressureWinterDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Winter mode low pressure delay in seconds (2249)" + ::= { airIRmPmCommon5 18 } + +airIRmPmUnitCondensationPressure2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit condensation pressure 2 in tenths of Bars (2250)" + ::= { airIRmPmCommon5 19 } + +airIRmPmUnitOverloadSwitch OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit overload switch setting in tenths of Kelvins (2251)" + ::= { airIRmPmCommon5 20 } + +airIRmPmUnitCondensationTemperature2 OBJECT IDENTIFIER ::= { airIRmPmCommon5 41 } +airIRmPmUnitCondensationTemperature2C OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit condensation temperature 2 in tenths + of degrees Celsius (2272)" + ::= { airIRmPmUnitCondensationTemperature2 1 } +airIRmPmUnitCondensationTemperature2F OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit condensation temperature 2 in tenths + of degrees Fahrenheit (2272)" + ::= { airIRmPmUnitCondensationTemperature2 2 } + +airIRmPmUnitEvaporationPressure2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit evaporation pressure 2 in tenths + of Bars (2273)" + ::= { airIRmPmCommon5 42 } + +airIRmPmUnitEvaporationTemperature2 OBJECT IDENTIFIER ::= { airIRmPmCommon5 43 } +airIRmPmUnitEvaporationTemperature2C OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit evaporation temperature 2 in tenths + of degrees Celsius (2274)" + ::= { airIRmPmUnitEvaporationTemperature2 1 } +airIRmPmUnitEvaporationTemperature2F OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unit evaporation temperature 2 in tenths + of degrees Fahrenheit (2274)" + ::= { airIRmPmUnitEvaporationTemperature2 2 } + +-- airIRmPmCompressor1 + +airIRmPmCmp1ManOperationActive OBJECT-TYPE + SYNTAX INTEGER { + automatic (1), + manual (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor 1 manual operation active (4401)" + ::= { airIRmPmCompressor1 2 } + +airIRmPmCmp1ManOperationState OBJECT-TYPE + SYNTAX AirIRmControlState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor 1 manual operation state (4402)" + ::= { airIRmPmCompressor1 3 } + +airIRmPmCmp1Running OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor 1 running (4403)" + ::= { airIRmPmCompressor1 4 } + +airIRmPmCmp1StartTempSummer OBJECT IDENTIFIER ::= { airIRmPmCompressor1 17 } +airIRmPmCmp1StartTempSummerK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 1 summer mode start temperature + in tenths of Kelvins (4416)" + ::= { airIRmPmCmp1StartTempSummer 1 } +airIRmPmCmp1StartTempSummerF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 1 summer mode start temperature + in tenths of degrees Fahrenheit (4416)" + ::= { airIRmPmCmp1StartTempSummer 2 } + +airIRmPmCmp1HysteresisSummer OBJECT IDENTIFIER ::= { airIRmPmCompressor1 18 } +airIRmPmCmp1HysteresisSummerK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 1 summer mode hysteresis setting + in tenths of Kelvins (4417)" + ::= { airIRmPmCmp1HysteresisSummer 1 } +airIRmPmCmp1HysteresisSummerF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 1 summer mode hysteresis setting + in tenths of Fahrenheit (4417)" + ::= { airIRmPmCmp1HysteresisSummer 2 } + +airIRmPmCmp1StartTempWinter OBJECT IDENTIFIER ::= { airIRmPmCompressor1 19 } +airIRmPmCmp1StartTempWinterK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 1 winter mode start temperature + in tenths of Kelvins (4418)" + ::= { airIRmPmCmp1StartTempWinter 1 } +airIRmPmCmp1StartTempWinterF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 1 winter mode start temperature + in tenths of degrees Fahrenheit (4418)" + ::= { airIRmPmCmp1StartTempWinter 2 } + +airIRmPmCmp1HysteresisWinter OBJECT IDENTIFIER ::= { airIRmPmCompressor1 20 } +airIRmPmCmp1HysteresisWinterK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 1 Winter mode hysteresis setting + in tenths of Kelvins (4419)" + ::= { airIRmPmCmp1HysteresisWinter 1 } +airIRmPmCmp1HysteresisWinterF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 1 Winter mode hysteresis setting + in tenths of Fahrenheit (4419)" + ::= { airIRmPmCmp1HysteresisWinter 2 } + +airIRmPmCmp1Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor 1 runtime in hours (4428)" + ::= { airIRmPmCompressor1 29 } + +-- airIRmPmCompressor2 + +airIRmPmCmp2ManOperationActive OBJECT-TYPE + SYNTAX INTEGER { + automatic (1), + manual (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor 2 manual operation active (4501)" + ::= { airIRmPmCompressor2 2 } + +airIRmPmCmp2ManOperationState OBJECT-TYPE + SYNTAX AirIRmControlState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor 2 manual operation state (4502)" + ::= { airIRmPmCompressor2 3 } + +airIRmPmCmp2Running OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor 2 running (4503)" + ::= { airIRmPmCompressor2 4 } + +airIRmPmCmp2StartTempSummer OBJECT IDENTIFIER ::= { airIRmPmCompressor2 17 } +airIRmPmCmp2StartTempSummerK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 2 summer mode start temperature + in tenths of Kelvins (4516)" + ::= { airIRmPmCmp2StartTempSummer 1 } +airIRmPmCmp2StartTempSummerF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 2 summer mode start temperature + in tenths of degrees Fahrenheit (4516)" + ::= { airIRmPmCmp2StartTempSummer 2 } + +airIRmPmCmp2HysteresisSummer OBJECT IDENTIFIER ::= { airIRmPmCompressor2 18 } +airIRmPmCmp2HysteresisSummerK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 2 summer mode hysteresis setting + in tenths of Kelvins (4517)" + ::= { airIRmPmCmp2HysteresisSummer 1 } +airIRmPmCmp2HysteresisSummerF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 2 summer mode hysteresis setting + in tenths of Fahrenheit (4517)" + ::= { airIRmPmCmp2HysteresisSummer 2 } + +airIRmPmCmp2StartTempWinter OBJECT IDENTIFIER ::= { airIRmPmCompressor2 19 } +airIRmPmCmp2StartTempWinterK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 2 winter mode start temperature + in tenths of Kelvins (4518)" + ::= { airIRmPmCmp2StartTempWinter 1 } +airIRmPmCmp2StartTempWinterF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 2 winter mode start temperature + in tenths of degrees Fahrenheit (4518)" + ::= { airIRmPmCmp2StartTempWinter 2 } + +airIRmPmCmp2HysteresisWinter OBJECT IDENTIFIER ::= { airIRmPmCompressor2 20 } +airIRmPmCmp2HysteresisWinterK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 2 Winter mode hysteresis setting + in tenths of Kelvins (4519)" + ::= { airIRmPmCmp2HysteresisWinter 1 } +airIRmPmCmp2HysteresisWinterF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Compressor 2 Winter mode hysteresis setting + in tenths of Fahrenheit (4519)" + ::= { airIRmPmCmp2HysteresisWinter 2 } + +airIRmPmCmp2Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor 2 runtime in hours (4528)" + ::= { airIRmPmCompressor2 29 } + +-- airIRmPmSuctionValve1 +-- Empty + +-- airIRmPmSuctionValve2 +-- Empty + +-- airIRmPmEheating1 + +airIRmPmEheating1ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #1 manual operation enable (4801)" + ::= { airIRmPmEheating1 2 } + +airIRmPmEheating1Running OBJECT-TYPE + SYNTAX AirIRmControlState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #1 running state (4803)" + ::= { airIRmPmEheating1 4 } + +airIRmPmEheating1ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #1 running in manual operation mode (4804)" + ::= { airIRmPmEheating1 5 } + +airIRmPmEheating1Type OBJECT-TYPE + SYNTAX INTEGER { + direct (1), + pwm (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #1 type (4808)" + ::= { airIRmPmEheating1 9 } + +airIRmPmEheating1StartTemperature OBJECT IDENTIFIER ::= { airIRmPmEheating1 10 } +airIRmPmEheating1StartTemperatureK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #1 start temperature in tenths of Kelvins (4809)" + ::= { airIRmPmEheating1StartTemperature 1 } +airIRmPmEheating1StartTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #1 start temperature in tenths of degrees Fahrenheit (4809)" + ::= { airIRmPmEheating1StartTemperature 2 } + +airIRmPmEheating1Hysteresis OBJECT IDENTIFIER ::= { airIRmPmEheating1 11 } +airIRmPmEheating1HysteresisK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #1 hysteresis in tenths of Kelvins (4810)" + ::= { airIRmPmEheating1Hysteresis 1 } +airIRmPmEheating1HysteresisF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #1 hysteresis in tenths of degrees Fahrenheit (4810)" + ::= { airIRmPmEheating1Hysteresis 2 } + +airIRmPmEheating1Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #1 runtime in hours (4816)" + ::= { airIRmPmEheating1 17 } + +-- airIRmPmEheating2 + +airIRmPmEheating2ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #2 manual operation enable (4901)" + ::= { airIRmPmEheating2 2 } + +airIRmPmEheating2Running OBJECT-TYPE + SYNTAX AirIRmControlState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #2 running state (4903)" + ::= { airIRmPmEheating2 4 } + +airIRmPmEheating2ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #2 running in manual operation mode (4904)" + ::= { airIRmPmEheating2 5 } + +airIRmPmEheating2Type OBJECT-TYPE + SYNTAX INTEGER { + direct (1), + pwm (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #2 type (4908)" + ::= { airIRmPmEheating2 9 } + +airIRmPmEheating2StartTemperature OBJECT IDENTIFIER ::= { airIRmPmEheating2 10 } +airIRmPmEheating2StartTemperatureK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #2 start temperature in tenths of Kelvins (4909)" + ::= { airIRmPmEheating2StartTemperature 1 } +airIRmPmEheating2StartTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #2 start temperature in tenths of degrees Fahrenheit (4909)" + ::= { airIRmPmEheating2StartTemperature 2 } + +airIRmPmEheating2Hysteresis OBJECT IDENTIFIER ::= { airIRmPmEheating2 11 } +airIRmPmEheating2HysteresisK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #2 hysteresis in tenths of Kelvins (4910)" + ::= { airIRmPmEheating2Hysteresis 1 } +airIRmPmEheating2HysteresisF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #2 hysteresis in tenths of degrees Fahrenheit (4910)" + ::= { airIRmPmEheating2Hysteresis 2 } + +airIRmPmEheating2Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #2 runtime in hours (4916)" + ::= { airIRmPmEheating2 17 } + +-- airIRmPmEheating3 + +airIRmPmEheating3ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #3 manual operation enable (5001)" + ::= { airIRmPmEheating3 2 } + +airIRmPmEheating3Running OBJECT-TYPE + SYNTAX AirIRmControlState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #3 running state (5003)" + ::= { airIRmPmEheating3 4 } + +airIRmPmEheating3ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #3 running in manual operation mode (5004)" + ::= { airIRmPmEheating3 5 } + +airIRmPmEheating3Type OBJECT-TYPE + SYNTAX INTEGER { + direct (1), + pwm (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #3 type (5008)" + ::= { airIRmPmEheating3 9 } + +airIRmPmEheating3StartTemperature OBJECT IDENTIFIER ::= { airIRmPmEheating3 10 } +airIRmPmEheating3StartTemperatureK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #3 start temperature in tenths of Kelvins (5009)" + ::= { airIRmPmEheating3StartTemperature 1 } +airIRmPmEheating3StartTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #3 start temperature in tenths of degrees Fahrenheit (5009)" + ::= { airIRmPmEheating3StartTemperature 2 } + +airIRmPmEheating3Hysteresis OBJECT IDENTIFIER ::= { airIRmPmEheating3 11 } +airIRmPmEheating3HysteresisK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #3 hysteresis in tenths of Kelvins (5010)" + ::= { airIRmPmEheating3Hysteresis 1 } +airIRmPmEheating3HysteresisF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #3 hysteresis in tenths of degrees Fahrenheit (5010)" + ::= { airIRmPmEheating3Hysteresis 2 } + +airIRmPmEheating3Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #3 runtime in hours (5016)" + ::= { airIRmPmEheating3 17 } + +-- airIRmPmEheating4 + +airIRmPmEheating4ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #4 manual operation enable (5101)" + ::= { airIRmPmEheating4 2 } + +airIRmPmEheating4Running OBJECT-TYPE + SYNTAX AirIRmControlState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #4 running state (5103)" + ::= { airIRmPmEheating4 4 } + +airIRmPmEheating4ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #4 running in manual operation mode (5104)" + ::= { airIRmPmEheating4 5 } + +airIRmPmEheating4Type OBJECT-TYPE + SYNTAX INTEGER { + direct (1), + pwm (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #4 type (5108)" + ::= { airIRmPmEheating4 9 } + +airIRmPmEheating4StartTemperature OBJECT IDENTIFIER ::= { airIRmPmEheating4 10 } +airIRmPmEheating4StartTemperatureK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #4 start temperature in tenths of Kelvins (5109)" + ::= { airIRmPmEheating4StartTemperature 1 } +airIRmPmEheating4StartTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #4 start temperature in tenths of degrees Fahrenheit (5109)" + ::= { airIRmPmEheating4StartTemperature 2 } + +airIRmPmEheating4Hysteresis OBJECT IDENTIFIER ::= { airIRmPmEheating4 11 } +airIRmPmEheating4HysteresisK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #4 hysteresis in tenths of Kelvins (5110)" + ::= { airIRmPmEheating4Hysteresis 1 } +airIRmPmEheating4HysteresisF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Electric heater #4 hysteresis in tenths of degrees Fahrenheit (5110)" + ::= { airIRmPmEheating4Hysteresis 2 } + +airIRmPmEheating4Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Electric heater #4 runtime in hours (5116)" + ::= { airIRmPmEheating4 17 } + +-- airIRmPmGECWvalve + +airIRmPmGECWvalveManOpEnable OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "GE/CW valve manual operation enable (5201)" + ::= { airIRmPmGECWvalve 2 } + +airIRmPmGECWvalveStartTemperature OBJECT IDENTIFIER ::= { airIRmPmGECWvalve 9 } +airIRmPmGECWvalveStartTemperatureK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "GE/CW valve start temperature in tenths of Kelvins (5208)" + ::= { airIRmPmGECWvalveStartTemperature 1 } +airIRmPmGECWvalveStartTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "GE/CW valve start temperature in tenths of degrees Fahrenheit (5208)" + ::= { airIRmPmGECWvalveStartTemperature 2 } + +airIRmPmGECWvalveLinearRange OBJECT IDENTIFIER ::= { airIRmPmGECWvalve 10 } +airIRmPmGECWvalveLinearRangeK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "GE/CW valve linear range in tenths of Kelvins (5209)" + ::= { airIRmPmGECWvalveLinearRange 1 } +airIRmPmGECWvalveLinearRangeF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "GE/CW valve linear range in tenths of degrees Fahrenheit (5209)" + ::= { airIRmPmGECWvalveLinearRange 2 } + +airIRmPmGECWvalveGEOffTemp OBJECT IDENTIFIER ::= { airIRmPmGECWvalve 12 } +airIRmPmGECWvalveGEOffTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "GE/CW valve GE off temperature in tenths of degrees Celsius (5211)" + ::= { airIRmPmGECWvalveGEOffTemp 1 } +airIRmPmGECWvalveGEOffTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "GE/CW valve GE off temperature in tenths of degrees Fahrenheit (5211)" + ::= { airIRmPmGECWvalveGEOffTemp 2 } + +airIRmPmGECWvalveOpeningGrade OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "GE/CW valve opening grade in percent (5214)" + ::= { airIRmPmGECWvalve 15 } + +airIRmPmGECWvalveManOpOpeningGrade OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "GE/CW valve manual operation opening grade in percent (5215)" + ::= { airIRmPmGECWvalve 16 } + +-- airIRmPmGvalve + +airIRmPmGvalveManOperationEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "G-valve manual operation enable (5301)" + ::= { airIRmPmGvalve 2 } + +airIRmPmGvalvePreOpeningTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "G-valve pre-opening time in seconds (5310)" + ::= { airIRmPmGvalve 11 } + +airIRmPmGvalvePreOpeningGrade OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "G-valve pre-opening grade in percent (5311)" + ::= { airIRmPmGvalve 12 } + +airIRmPmGvalveOpeningGrade OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "G-valve opening grade in percent (5312)" + ::= { airIRmPmGvalve 13 } + +airIRmPmGvalveManOpOpeningGrade OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "G-valve manual operation opening grade in percent (5313)" + ::= { airIRmPmGvalve 14 } + +-- airIRmPmDrycooler1 + +airIRmPmDrycooler1ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 1 manual operation enable setting (5401)" + ::= { airIRmPmDrycooler1 2 } + +airIRmPmDrycooler1Running OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 1 running (5402)" + ::= { airIRmPmDrycooler1 3 } + +airIRmPmDrycooler1ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 1 manual operation running (5404)" + ::= { airIRmPmDrycooler1 5 } + +airIRmPmDrycooler1WinterStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler1 9 } +airIRmPmDrycooler1WinterStartTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 1 winter mode start temperature + in tenths of degrees Celsius (5408)" + ::= { airIRmPmDrycooler1WinterStartTemp 1 } +airIRmPmDrycooler1WinterStartTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 1 winter mode start temperature + in tenths of degrees Fahrenheit (5408)" + ::= { airIRmPmDrycooler1WinterStartTemp 2 } + +airIRmPmDrycooler1SummerStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler1 10 } +airIRmPmDrycooler1SummerStartTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 1 summer mode start temperature + in tenths of degrees Celsius (5409)" + ::= { airIRmPmDrycooler1SummerStartTemp 1 } +airIRmPmDrycooler1SummerStartTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 1 summer mode start temperature + in tenths of degrees Fahrenheit (5409)" + ::= { airIRmPmDrycooler1SummerStartTemp 2 } + +airIRmPmDrycooler1Hysteresis OBJECT IDENTIFIER ::= { airIRmPmDrycooler1 11 } +airIRmPmDrycooler1HysteresisK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 1 hysteresis in tenths of Kelvins (5410)" + ::= { airIRmPmDrycooler1Hysteresis 1 } +airIRmPmDrycooler1HysteresisF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 1 hysteresis in tenths of degrees Fahrenheit (5410)" + ::= { airIRmPmDrycooler1Hysteresis 2 } + +airIRmPmDrycooler1Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 1 runtime in hours (5415)" + ::= { airIRmPmDrycooler1 16 } + +-- airIRmPmDrycooler2 + +airIRmPmDrycooler2ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 2 manual operation enable setting (5501)" + ::= { airIRmPmDrycooler2 2 } + +airIRmPmDrycooler2Running OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 2 running (5502)" + ::= { airIRmPmDrycooler2 3 } + +airIRmPmDrycooler2ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 2 manual operation running (5504)" + ::= { airIRmPmDrycooler2 5 } + +airIRmPmDrycooler2WinterStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler2 9 } +airIRmPmDrycooler2WinterStartTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 2 winter mode start temperature + in tenths of degrees Celsius (5508)" + ::= { airIRmPmDrycooler2WinterStartTemp 1 } +airIRmPmDrycooler2WinterStartTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 2 winter mode start temperature + in tenths of degrees Fahrenheit (5508)" + ::= { airIRmPmDrycooler2WinterStartTemp 2 } + +airIRmPmDrycooler2SummerStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler2 10 } +airIRmPmDrycooler2SummerStartTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 2 summer mode start temperature + in tenths of degrees Celsius (5509)" + ::= { airIRmPmDrycooler2SummerStartTemp 1 } +airIRmPmDrycooler2SummerStartTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 2 summer mode start temperature + in tenths of degrees Fahrenheit (5509)" + ::= { airIRmPmDrycooler2SummerStartTemp 2 } + +airIRmPmDrycooler2Hysteresis OBJECT IDENTIFIER ::= { airIRmPmDrycooler2 11 } +airIRmPmDrycooler2HysteresisK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 2 hysteresis in tenths of Kelvins (5510)" + ::= { airIRmPmDrycooler2Hysteresis 1 } +airIRmPmDrycooler2HysteresisF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 2 hysteresis in tenths of degrees Fahrenheit (5510)" + ::= { airIRmPmDrycooler2Hysteresis 2 } + +airIRmPmDrycooler2Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 2 runtime in hours (5515)" + ::= { airIRmPmDrycooler2 16 } + +-- airIRmPmDrycooler3 + +airIRmPmDrycooler3ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 3 manual operation enable setting (5601)" + ::= { airIRmPmDrycooler3 2 } + +airIRmPmDrycooler3Running OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 3 running (5602)" + ::= { airIRmPmDrycooler3 3 } + +airIRmPmDrycooler3ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 3 manual operation running (5604)" + ::= { airIRmPmDrycooler3 5 } + +airIRmPmDrycooler3WinterStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler3 9 } +airIRmPmDrycooler3WinterStartTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 3 winter mode start temperature + in tenths of degrees Celsius (5608)" + ::= { airIRmPmDrycooler3WinterStartTemp 1 } +airIRmPmDrycooler3WinterStartTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 3 winter mode start temperature + in tenths of degrees Fahrenheit (5608)" + ::= { airIRmPmDrycooler3WinterStartTemp 2 } + +airIRmPmDrycooler3SummerStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler3 10 } +airIRmPmDrycooler3SummerStartTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 3 summer mode start temperature + in tenths of degrees Celsius (5609)" + ::= { airIRmPmDrycooler3SummerStartTemp 1 } +airIRmPmDrycooler3SummerStartTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 3 summer mode start temperature + in tenths of degrees Fahrenheit (5609)" + ::= { airIRmPmDrycooler3SummerStartTemp 2 } + +airIRmPmDrycooler3Hysteresis OBJECT IDENTIFIER ::= { airIRmPmDrycooler3 11 } +airIRmPmDrycooler3HysteresisK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 3 hysteresis in tenths of Kelvins (5610)" + ::= { airIRmPmDrycooler3Hysteresis 1 } +airIRmPmDrycooler3HysteresisF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 3 hysteresis in tenths of degrees Fahrenheit (5610)" + ::= { airIRmPmDrycooler3Hysteresis 2 } + +airIRmPmDrycooler3Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 3 runtime in hours (5615)" + ::= { airIRmPmDrycooler3 16 } + +-- airIRmPmDrycooler4 + +airIRmPmDrycooler4ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 4 manual operation enable setting (5701)" + ::= { airIRmPmDrycooler4 2 } + +airIRmPmDrycooler4Running OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 4 running (5702)" + ::= { airIRmPmDrycooler4 3 } + +airIRmPmDrycooler4ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 4 manual operation running (5704)" + ::= { airIRmPmDrycooler4 5 } + +airIRmPmDrycooler4WinterStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler4 9 } +airIRmPmDrycooler4WinterStartTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 4 winter mode start temperature + in tenths of degrees Celsius (5708)" + ::= { airIRmPmDrycooler4WinterStartTemp 1 } +airIRmPmDrycooler4WinterStartTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 4 winter mode start temperature + in tenths of degrees Fahrenheit (5708)" + ::= { airIRmPmDrycooler4WinterStartTemp 2 } + +airIRmPmDrycooler4SummerStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler4 10 } +airIRmPmDrycooler4SummerStartTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 4 summer mode start temperature + in tenths of degrees Celsius (5709)" + ::= { airIRmPmDrycooler4SummerStartTemp 1 } +airIRmPmDrycooler4SummerStartTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 4 summer mode start temperature + in tenths of degrees Fahrenheit (5709)" + ::= { airIRmPmDrycooler4SummerStartTemp 2 } + +airIRmPmDrycooler4Hysteresis OBJECT IDENTIFIER ::= { airIRmPmDrycooler4 11 } +airIRmPmDrycooler4HysteresisK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 4 hysteresis in tenths of Kelvins (5710)" + ::= { airIRmPmDrycooler4Hysteresis 1 } +airIRmPmDrycooler4HysteresisF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Drycooler 4 hysteresis in tenths of degrees Fahrenheit (5710)" + ::= { airIRmPmDrycooler4Hysteresis 2 } + +airIRmPmDrycooler4Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler 4 runtime in hours (5715)" + ::= { airIRmPmDrycooler4 16 } + +-- airIRmPmPump1 + +airIRmPmPump1ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 1 manual operation enable state (5801)" + ::= { airIRmPmPump1 2 } + +airIRmPmPump1Running OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 1 running (5802)" + ::= { airIRmPmPump1 3 } + +airIRmPmPump1ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 1 manual operation running (5805)" + ::= { airIRmPmPump1 6 } + +airIRmPmPump1StartTemperature OBJECT IDENTIFIER ::= { airIRmPmPump1 10 } +airIRmPmPump1StartTemperatureK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 1 starting temperature in tenths of Kelvins (5809)" + ::= { airIRmPmPump1StartTemperature 1 } +airIRmPmPump1StartTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 1 starting temperature in tenths of degrees Fahrenheit (5809)" + ::= { airIRmPmPump1StartTemperature 2 } + +airIRmPmPump1Hysteresis OBJECT IDENTIFIER ::= { airIRmPmPump1 11 } +airIRmPmPump1HysteresisK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 1 hysteresis in tenths of Kelvins (5810)" + ::= { airIRmPmPump1Hysteresis 1 } +airIRmPmPump1HysteresisF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 1 hysteresis in tenths of degrees Fahrenheit (5810)" + ::= { airIRmPmPump1Hysteresis 2 } + +airIRmPmPump1LinearRange OBJECT IDENTIFIER ::= { airIRmPmPump1 12 } +airIRmPmPump1LinearRangeK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 1 linear range in tenths of Kelvins (5811)" + ::= { airIRmPmPump1LinearRange 1 } +airIRmPmPump1LinearRangeF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 1 linear range in tenths of degrees Fahrenheit (5811)" + ::= { airIRmPmPump1LinearRange 2 } + +airIRmPmPump1PressureSetpoint OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 1 pressure setpoint in tenths of Bars (5812)" + ::= { airIRmPmPump1 13 } + +airIRmPmPump1Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 1 runtime in hours (5820)" + ::= { airIRmPmPump1 21 } + +airIRmPmPump1Speed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 1 speed in percent (5821)" + ::= { airIRmPmPump1 22 } + +airIRmPmPump1ControlCycle OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 1 control cycle length in seconds (5827)" + ::= { airIRmPmPump1 28 } + +airIRmPmPump1MaxAdjust OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 1 maximum adjustment in percent (5828)" + ::= { airIRmPmPump1 29 } + +airIRmPmPump1ControlFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 1 control factor setting (5829)" + ::= { airIRmPmPump1 30 } + +-- airIRmPmPump2 + +airIRmPmPump2ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 2 manual operation enable state (5901)" + ::= { airIRmPmPump2 2 } + +airIRmPmPump2Running OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 2 running (5902)" + ::= { airIRmPmPump2 3 } + +airIRmPmPump2ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 2 manual operation running (5905)" + ::= { airIRmPmPump2 6 } + +airIRmPmPump2StartTemperature OBJECT IDENTIFIER ::= { airIRmPmPump2 10 } +airIRmPmPump2StartTemperatureK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 2 starting temperature in tenths of Kelvins (5909)" + ::= { airIRmPmPump2StartTemperature 1 } +airIRmPmPump2StartTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 2 starting temperature in tenths of degrees Fahrenheit (5909)" + ::= { airIRmPmPump2StartTemperature 2 } + +airIRmPmPump2Hysteresis OBJECT IDENTIFIER ::= { airIRmPmPump2 11 } +airIRmPmPump2HysteresisK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 2 hysteresis in tenths of Kelvins (5910)" + ::= { airIRmPmPump2Hysteresis 1 } +airIRmPmPump2HysteresisF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 2 hysteresis in tenths of degrees Fahrenheit (5910)" + ::= { airIRmPmPump2Hysteresis 2 } + +airIRmPmPump2LinearRange OBJECT IDENTIFIER ::= { airIRmPmPump2 12 } +airIRmPmPump2LinearRangeK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 2 linear range in tenths of Kelvins (5911)" + ::= { airIRmPmPump2LinearRange 1 } +airIRmPmPump2LinearRangeF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 2 linear range in tenths of degrees Fahrenheit (5911)" + ::= { airIRmPmPump2LinearRange 2 } + +airIRmPmPump2PressureSetpoint OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 2 pressure setpoint in tenths of Bars (5912)" + ::= { airIRmPmPump2 13 } + +airIRmPmPump2Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 2 runtime in hours (5920)" + ::= { airIRmPmPump2 21 } + +airIRmPmPump2Speed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 2 speed in percent (5921)" + ::= { airIRmPmPump2 22 } + +airIRmPmPump2ControlCycle OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 2 control cycle length in seconds (5927)" + ::= { airIRmPmPump2 28 } + +airIRmPmPump2MaxAdjust OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 2 maximum adjustment in percent (5928)" + ::= { airIRmPmPump2 29 } + +airIRmPmPump2ControlFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 2 control factor setting (5929)" + ::= { airIRmPmPump2 30 } + +-- airIRmPmPump3 + +airIRmPmPump3ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 3 manual operation enable state (6001)" + ::= { airIRmPmPump3 2 } + +airIRmPmPump3Running OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 3 running (6002)" + ::= { airIRmPmPump3 3 } + +airIRmPmPump3ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 3 manual operation running (6005)" + ::= { airIRmPmPump3 6 } + +airIRmPmPump3StartTemperature OBJECT IDENTIFIER ::= { airIRmPmPump3 10 } +airIRmPmPump3StartTemperatureK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 3 starting temperature in tenths of Kelvins (6009)" + ::= { airIRmPmPump3StartTemperature 1 } +airIRmPmPump3StartTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 3 starting temperature in tenths of degrees Fahrenheit (6009)" + ::= { airIRmPmPump3StartTemperature 2 } + +airIRmPmPump3Hysteresis OBJECT IDENTIFIER ::= { airIRmPmPump3 11 } +airIRmPmPump3HysteresisK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 3 hysteresis in tenths of Kelvins (6010)" + ::= { airIRmPmPump3Hysteresis 1 } +airIRmPmPump3HysteresisF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 3 hysteresis in tenths of degrees Fahrenheit (6010)" + ::= { airIRmPmPump3Hysteresis 2 } + +airIRmPmPump3LinearRange OBJECT IDENTIFIER ::= { airIRmPmPump3 12 } +airIRmPmPump3LinearRangeK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 3 linear range in tenths of Kelvins (6011)" + ::= { airIRmPmPump3LinearRange 1 } +airIRmPmPump3LinearRangeF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 3 linear range in tenths of degrees Fahrenheit (6011)" + ::= { airIRmPmPump3LinearRange 2 } + +airIRmPmPump3PressureSetpoint OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 3 pressure setpoint in tenths of Bars (6012)" + ::= { airIRmPmPump3 13 } + +airIRmPmPump3Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 3 runtime in hours (6020)" + ::= { airIRmPmPump3 21 } + +airIRmPmPump3Speed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 3 speed in percent (6021)" + ::= { airIRmPmPump3 22 } + +airIRmPmPump3ControlCycle OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 3 control cycle length in seconds (6027)" + ::= { airIRmPmPump3 28 } + +airIRmPmPump3MaxAdjust OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 3 maximum adjustment in percent (6028)" + ::= { airIRmPmPump3 29 } + +airIRmPmPump3ControlFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 3 control factor setting (6029)" + ::= { airIRmPmPump3 30 } + +-- airIRmPmPump4 + +airIRmPmPump4ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 4 manual operation enable state (6101)" + ::= { airIRmPmPump4 2 } + +airIRmPmPump4Running OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 4 running (6102)" + ::= { airIRmPmPump4 3 } + +airIRmPmPump4ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 4 manual operation running (6105)" + ::= { airIRmPmPump4 6 } + +airIRmPmPump4StartTemperature OBJECT IDENTIFIER ::= { airIRmPmPump4 10 } +airIRmPmPump4StartTemperatureK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 4 starting temperature in tenths of Kelvins (6109)" + ::= { airIRmPmPump4StartTemperature 1 } +airIRmPmPump4StartTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 4 starting temperature in tenths of degrees Fahrenheit (6109)" + ::= { airIRmPmPump4StartTemperature 2 } + +airIRmPmPump4Hysteresis OBJECT IDENTIFIER ::= { airIRmPmPump4 11 } +airIRmPmPump4HysteresisK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 4 hysteresis in tenths of Kelvins (6110)" + ::= { airIRmPmPump4Hysteresis 1 } +airIRmPmPump4HysteresisF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 4 hysteresis in tenths of degrees Fahrenheit (6110)" + ::= { airIRmPmPump4Hysteresis 2 } + +airIRmPmPump4LinearRange OBJECT IDENTIFIER ::= { airIRmPmPump4 12 } +airIRmPmPump4LinearRangeK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 4 linear range in tenths of Kelvins (6111)" + ::= { airIRmPmPump4LinearRange 1 } +airIRmPmPump4LinearRangeF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 4 linear range in tenths of degrees Fahrenheit (6111)" + ::= { airIRmPmPump4LinearRange 2 } + +airIRmPmPump4PressureSetpoint OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 4 pressure setpoint in tenths of Bars (6112)" + ::= { airIRmPmPump4 13 } + +airIRmPmPump4Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 4 runtime in hours (6120)" + ::= { airIRmPmPump4 21 } + +airIRmPmPump4Speed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump 4 speed in percent (6121)" + ::= { airIRmPmPump4 22 } + +airIRmPmPump4ControlCycle OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 4 control cycle length in seconds (6127)" + ::= { airIRmPmPump4 28 } + +airIRmPmPump4MaxAdjust OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 4 maximum adjustment in percent (6128)" + ::= { airIRmPmPump4 29 } + +airIRmPmPump4ControlFactor OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Pump 4 control factor setting (6129)" + ::= { airIRmPmPump4 30 } + +-- airIRmPmHotgasHeating + +airIRmPmHotgasHeatRunning OBJECT-TYPE + SYNTAX AirIRmControlState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Hotgas heat running state. (6202)" + ::= { airIRmPmHotgasHeating 3 } + +-- airIRmPmPWWHeating + +airIRmPmPWWHeatingManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "PWW-heating manual operation enable (6301)" + ::= { airIRmPmPWWHeating 2 } + +airIRmPmPWWHeatingRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "PWW-heating running (6302)" + ::= { airIRmPmPWWHeating 3 } + +airIRmPmPWWHeatingManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "PWW-heating manual operation running (6303)" + ::= { airIRmPmPWWHeating 4 } + +airIRmPmPWWHeatingType OBJECT-TYPE + SYNTAX INTEGER { + direct (1), + undefined (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "PWW-heating type (6308)" + ::= { airIRmPmPWWHeating 9 } + +airIRmPmPWWHeatingStartTemp OBJECT IDENTIFIER ::= { airIRmPmPWWHeating 10 } +airIRmPmPWWHeatingStartTempK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "PWW-heating starting temperature in Kelvins (6309)" + ::= { airIRmPmPWWHeatingStartTemp 1 } +airIRmPmPWWHeatingStartTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "PWW-heating starting temperature in degrees Fahrenheit (6309)" + ::= { airIRmPmPWWHeatingStartTemp 2 } + +airIRmPmPWWHeatingHysteresis OBJECT IDENTIFIER ::= { airIRmPmPWWHeating 12 } +airIRmPmPWWHeatingHysteresisK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "PWW-heating hysteresis in Kelvins (6311)" + ::= { airIRmPmPWWHeatingHysteresis 1 } +airIRmPmPWWHeatingHysteresisF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "PWW-heating hysteresis in degrees Fahrenheit (6311)" + ::= { airIRmPmPWWHeatingHysteresis 2 } + +airIRmPmPWWHeatingLinearRange OBJECT IDENTIFIER ::= { airIRmPmPWWHeating 13 } +airIRmPmPWWHeatingLinearRangeK OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "PWW-heating linear range in Kelvins (6312)" + ::= { airIRmPmPWWHeatingLinearRange 1 } +airIRmPmPWWHeatingLinearRangeF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "PWW-heating linear range in degrees Fahrenheit (6312)" + ::= { airIRmPmPWWHeatingLinearRange 2 } + +airIRmPmPWWHeatingCurrentValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "PWW-heating current value in percent (6315)" + ::= { airIRmPmPWWHeating 16 } + +airIRmPmPWWHeatingManOpValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "PWW-heating manual operation value in percent (6316)" + ::= { airIRmPmPWWHeating 17 } + +-- airIRmPmHumidifier1 + +airIRmPmHumidifier1ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #1 manual operation enable (6401)" + ::= { airIRmPmHumidifier1 2 } + +airIRmPmHumidifier1Running OBJECT-TYPE + SYNTAX AirIRmControlState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #1 running state (6402)" + ::= { airIRmPmHumidifier1 3 } + +airIRmPmHumidifier1ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #1 manual operation running state (6404)" + ::= { airIRmPmHumidifier1 5 } + +airIRmPmHumidifier1Type OBJECT-TYPE + SYNTAX INTEGER { + direct (1), + proportional (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #1 type (6416)" + ::= { airIRmPmHumidifier1 17 } + +airIRmPmHumidifier1StartHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Humidifier #1 start humidity in tenths + of percent relative humidity (6417)" + ::= { airIRmPmHumidifier1 18 } + + +airIRmPmHumidifier1Hysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Humidifier #1 hysteresis in tenths + of percent relative humidity (6419)" + ::= { airIRmPmHumidifier1 20 } + +airIRmPmHumidifier1LinearRange OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Humidifier #1 linear range in tenths + of percent relative humidity per Kelvin (6420)" + ::= { airIRmPmHumidifier1 21 } + +airIRmPmHumidifier1Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #1 runtime in hours (6426)" + ::= { airIRmPmHumidifier1 27 } + +airIRmPmHumidifier1CurrentValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #1 current value in percent (6427)" + ::= { airIRmPmHumidifier1 28 } + +airIRmPmHumidifier1ManOpValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Humidifier #1 manual operation value in percent (6428)" + ::= { airIRmPmHumidifier1 29 } + +-- airIRmPmHumidifier2 + +airIRmPmHumidifier2ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #2 manual operation enable (6501)" + ::= { airIRmPmHumidifier2 2 } + +airIRmPmHumidifier2Running OBJECT-TYPE + SYNTAX AirIRmControlState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #2 running state (6502)" + ::= { airIRmPmHumidifier2 3 } + +airIRmPmHumidifier2ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #2 manual operation running state (6504)" + ::= { airIRmPmHumidifier2 5 } + +airIRmPmHumidifier2Type OBJECT-TYPE + SYNTAX INTEGER { + direct (1), + proportional (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #2 type (6516)" + ::= { airIRmPmHumidifier2 17 } + +airIRmPmHumidifier2StartHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Humidifier #2 start humidity in tenths + of percent relative humidity (6517)" + ::= { airIRmPmHumidifier2 18 } + +airIRmPmHumidifier2Hysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Humidifier #2 hysteresis in tenths + of percent relative humidity (6519)" + ::= { airIRmPmHumidifier2 20 } + +airIRmPmHumidifier2LinearRange OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Humidifier #2 linear range in tenths + of percent relative humidity per Kelvin (6520)" + ::= { airIRmPmHumidifier2 21 } + +airIRmPmHumidifier2Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #2 runtime in hours (6526)" + ::= { airIRmPmHumidifier2 27 } + +airIRmPmHumidifier2CurrentValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #2 current value in percent (6527)" + ::= { airIRmPmHumidifier2 28 } + +airIRmPmHumidifier2ManOpValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Humidifier #2 manual operation value in percent (6528)" + ::= { airIRmPmHumidifier2 29 } + +-- airIRmPmDehumidification + +airIRmPmDehumidificManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Dehumidifier manual operation enable setting (6801)" + ::= { airIRmPmDehumidification 2 } + +airIRmPmDehumidificRunning OBJECT-TYPE + SYNTAX AirIRmControlState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Dehumidifier running state (6802)" + ::= { airIRmPmDehumidification 3 } + +airIRmPmDehumidificManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Dehumidifier manual operation running (6804)" + ::= { airIRmPmDehumidification 5 } + +airIRmPmDehumidificStartHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dehumidifier start humidity in tenths of percent relative humidity (6809)" + ::= { airIRmPmDehumidification 10 } + +airIRmPmDehumidificHysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dehumidifier hysteresis in tenths of percent relative humidity (6811)" + ::= { airIRmPmDehumidification 12 } + +airIRmPmDehumidificMinWaterTemp OBJECT IDENTIFIER ::= { airIRmPmDehumidification 18 } +airIRmPmDehumidificMinWaterTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dehumidifier minimum water temperature in tenths of + degrees Celsius (6817)" + ::= { airIRmPmDehumidificMinWaterTemp 1 } +airIRmPmDehumidificMinWaterTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dehumidifier minimum water temperature in tenths of + degrees Fahrenheit (6817)" + ::= { airIRmPmDehumidificMinWaterTemp 2 } + +airIRmPmDehumidificMaxWaterTemp OBJECT IDENTIFIER ::= { airIRmPmDehumidification 19 } +airIRmPmDehumidificMaxWaterTempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dehumidifier maximum water temperature in tenths of + degrees Celsius (6818)" + ::= { airIRmPmDehumidificMaxWaterTemp 1 } +airIRmPmDehumidificMaxWaterTempF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dehumidifier maximum water temperature in tenths of + degrees Fahrenheit (6818)" + ::= { airIRmPmDehumidificMaxWaterTemp 2 } + +airIRmPmDehumidificRuntime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dehumidifier runtime in hours (6820)" + ::= { airIRmPmDehumidification 21 } + +-- airIRmPmFan1 + +airIRmPmFan1ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 manual operation enable (6901)" + ::= { airIRmPmFan1 2 } + +airIRmPmFan1Running OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 running (6902)" + ::= { airIRmPmFan1 3 } + +airIRmPmFan1ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 manual operation running (6905)" + ::= { airIRmPmFan1 6 } + +airIRmPmFan1Type OBJECT-TYPE + SYNTAX INTEGER { + direct (1), + proportional (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 type (6908)" + ::= { airIRmPmFan1 9 } + +airIRmPmFan1Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 runtime in hours (6931)" + ::= { airIRmPmFan1 32 } + +airIRmPmFan1Speed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 speed in percent (6932)" + ::= { airIRmPmFan1 33 } + +airIRmPmFan1ManOpSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 manual operation speed in percent (6933)" + ::= { airIRmPmFan1 34 } + +-- airIRmPmFan2 + +airIRmPmFan2ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 manual operation enable (7001)" + ::= { airIRmPmFan2 2 } + +airIRmPmFan2Running OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 running (7002)" + ::= { airIRmPmFan2 3 } + +airIRmPmFan2ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 manual operation running (7005)" + ::= { airIRmPmFan2 6 } + +airIRmPmFan2Type OBJECT-TYPE + SYNTAX INTEGER { + direct (1), + proportional (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 2 type (7008)" + ::= { airIRmPmFan2 9 } + +airIRmPmFan2Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 runtime in hours (7031)" + ::= { airIRmPmFan2 32 } + +airIRmPmFan2Speed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 speed in percent (7032)" + ::= { airIRmPmFan2 33 } + +airIRmPmFan2ManOpSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 manual operation speed in percent (7033)" + ::= { airIRmPmFan2 34 } + +-- airIRmPmFan3 + +airIRmPmFan3ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 manual operation enable (7101)" + ::= { airIRmPmFan3 2 } + +airIRmPmFan3Running OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 running (7102)" + ::= { airIRmPmFan3 3 } + +airIRmPmFan3ManOpRunning OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 manual operation running (7105)" + ::= { airIRmPmFan3 6 } + +airIRmPmFan3Type OBJECT-TYPE + SYNTAX INTEGER { + direct (1), + proportional (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 3 type (7108)" + ::= { airIRmPmFan3 9 } + +airIRmPmFan3Runtime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 runtime in hours (7131)" + ::= { airIRmPmFan3 32 } + +airIRmPmFan3Speed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 speed in percent (7132)" + ::= { airIRmPmFan3 33 } + +airIRmPmFan3ManOpSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan 1 manual operation speed in percent (7133)" + ::= { airIRmPmFan3 34 } + +-- airIRmPmLouver1 + +airIRmPmLouver1ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Louver 1 manual operation enable (7201)" + ::= { airIRmPmLouver1 2 } + +airIRmPmLouver1Position OBJECT-TYPE + SYNTAX INTEGER { + closed (1), + open (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Louver 1 position (7202)" + ::= { airIRmPmLouver1 3 } + +airIRmPmLouver1ManOpPosition OBJECT-TYPE + SYNTAX INTEGER { + closed (1), + open (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Louver 1 manual operation position setting (7203)" + ::= { airIRmPmLouver1 4 } + +-- airIRmPmLouver2 + +airIRmPmLouver2ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Louver 2 manual operation enable (7301)" + ::= { airIRmPmLouver2 2 } + +airIRmPmLouver2Position OBJECT-TYPE + SYNTAX INTEGER { + closed (1), + open (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Louver 2 position (7302)" + ::= { airIRmPmLouver2 3 } + +airIRmPmLouver2ManOpPosition OBJECT-TYPE + SYNTAX INTEGER { + closed (1), + open (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Louver 2 manual operation position setting (7303)" + ::= { airIRmPmLouver2 4 } + +-- airIRmPmLouver3 + +airIRmPmLouver3ManOpEnable OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Louver 3 manual operation enable (7401)" + ::= { airIRmPmLouver3 2 } + +airIRmPmLouver3Position OBJECT-TYPE + SYNTAX INTEGER { + closed (1), + open (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Louver 3 position (7402)" + ::= { airIRmPmLouver3 3 } + +airIRmPmLouver3ManOpPosition OBJECT-TYPE + SYNTAX INTEGER { + closed (1), + open (2) } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Louver 3 manual operation position setting (7403)" + ::= { airIRmPmLouver3 4 } + +-- airIRmPmAuxAlarm1 +-- Empty + +-- airIRmPmAuxAlarm2 +-- Empty + +-- airIRmPmAuxAlarm3 +-- Empty + +-- airIRmPmAuxAlarm4 +-- Empty + +-- airIRmPmAuxAlarm5 +-- Empty + + +-- airIRmPmAlarmBits + +airIRmPmFan1Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan #1 failure (8500)." + ::= { airIRmPmAlarmBits 1 } + +airIRmPmFan2Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan #2 failure (8501)." + ::= { airIRmPmAlarmBits 2 } + +airIRmPmFan3Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan #3 failure (8502)." + ::= { airIRmPmAlarmBits 3 } + +airIRmPmCompressor1Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor #1 failure (8503)." + ::= { airIRmPmAlarmBits 4 } + +airIRmPmCompressor2Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor #2 failure (8504)." + ::= { airIRmPmAlarmBits 5 } + +airIRmPmWaterDetector OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Water detector alarm (8505)." + ::= { airIRmPmAlarmBits 6 } + +airIRmPmPhaseFailure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Phase failure (8506)." + ::= { airIRmPmAlarmBits 7 } + +airIRmPmFireSmokeDetector OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fire/smoke detector (8507)." + ::= { airIRmPmAlarmBits 8 } + +airIRmPmReturnAirTemperatureTooHigh OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Return air temperature too high (8508)." + ::= { airIRmPmAlarmBits 9 } + +airIRmPmReturnAirHumidityTooHigh OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Return air humidity too high (8509)." + ::= { airIRmPmAlarmBits 10 } + +airIRmPmSupplyAirTemperatureTooHigh OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Supply air temperature too high (8510)." + ::= { airIRmPmAlarmBits 11 } + +airIRmPmSupplyAirHumidityTooHigh OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Supply air humidity too high (8511)." + ::= { airIRmPmAlarmBits 12 } + +airIRmPmWaterTemperatureTooHigh OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Water temperature too high (8512)." + ::= { airIRmPmAlarmBits 13 } + +airIRmPmReturnAirTemperatureTooLow OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Return air temperature too low (8513)." + ::= { airIRmPmAlarmBits 14 } + +airIRmPmReturnAirHumidityTooLow OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Return air humidity too low (8514)." + ::= { airIRmPmAlarmBits 15 } + +airIRmPmSupplyAirTemperatureTooLow OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Supply air temperature too low (8515)." + ::= { airIRmPmAlarmBits 16 } + +airIRmPmSupplyAirHumidityTooLow OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Supply air humidity too low (8516)." + ::= { airIRmPmAlarmBits 17 } + +airIRmPmWaterTemperatureTooLow OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Water temperature too low (8517)." + ::= { airIRmPmAlarmBits 18 } + +airIRmPmSensor1Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #1 failure (8518)." + ::= { airIRmPmAlarmBits 19 } + +airIRmPmSensor2Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #2 failure (8519)." + ::= { airIRmPmAlarmBits 20 } + +airIRmPmSensor3Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #3 failure (8520)." + ::= { airIRmPmAlarmBits 21 } + +airIRmPmSensor4Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #4 failure (8521)." + ::= { airIRmPmAlarmBits 22 } + +airIRmPmSensor5Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #5 failure (8522)." + ::= { airIRmPmAlarmBits 23 } + +airIRmPmSensor6Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #6 failure (8523)." + ::= { airIRmPmAlarmBits 24 } + +airIRmPmSensor7Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #7 failure (8524)." + ::= { airIRmPmAlarmBits 25 } + +airIRmPmSensor8Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #8 failure (8525)." + ::= { airIRmPmAlarmBits 26 } + +airIRmPmSensor9Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #9 failure (8526)." + ::= { airIRmPmAlarmBits 27 } + +airIRmPmSensor10Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #10 failure (8527)." + ::= { airIRmPmAlarmBits 28 } + +airIRmPmSensor11Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #11 failure (8528)." + ::= { airIRmPmAlarmBits 29 } + +airIRmPmSensor12Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #12 failure (8529)." + ::= { airIRmPmAlarmBits 30 } + +airIRmPmSensor13Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #13 failure (8530)." + ::= { airIRmPmAlarmBits 31 } + +airIRmPmSensor14Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #14 failure (8531)." + ::= { airIRmPmAlarmBits 32 } + +airIRmPmSensor15Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #15 failure (8532)." + ::= { airIRmPmAlarmBits 33 } + +airIRmPmSensor16Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #16 failure (8533)." + ::= { airIRmPmAlarmBits 34 } + +airIRmPmSensor17Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #17 failure (8534)." + ::= { airIRmPmAlarmBits 35 } + +airIRmPmSensor18Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #18 failure (8535)." + ::= { airIRmPmAlarmBits 36 } + +airIRmPmSensor19Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #19 failure (8536)." + ::= { airIRmPmAlarmBits 37 } + +airIRmPmSensor20Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #20 failure (8537)." + ::= { airIRmPmAlarmBits 38 } + +airIRmPmSensor21Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #21 failure (8538)." + ::= { airIRmPmAlarmBits 39 } + +airIRmPmSensor1Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #1 defect (8539)." + ::= { airIRmPmAlarmBits 40 } + +airIRmPmSensor2Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #2 defect (8540)." + ::= { airIRmPmAlarmBits 41 } + +airIRmPmSensor3Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #3 defect (8541)." + ::= { airIRmPmAlarmBits 42 } + +airIRmPmSensor4Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #4 defect (8542)." + ::= { airIRmPmAlarmBits 43 } + +airIRmPmSensor5Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #5 defect (8543)." + ::= { airIRmPmAlarmBits 44 } + +airIRmPmSensor6Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #6 defect (8544)." + ::= { airIRmPmAlarmBits 45 } + +airIRmPmSensor7Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #7 defect (8545)." + ::= { airIRmPmAlarmBits 46 } + +airIRmPmSensor8Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #8 defect (8546)." + ::= { airIRmPmAlarmBits 47 } + +airIRmPmSensor9Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #9 defect (8547)." + ::= { airIRmPmAlarmBits 48 } + +airIRmPmSensor10Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #10 defect (8548)." + ::= { airIRmPmAlarmBits 49 } + +airIRmPmSensor11Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #11 defect (8549)." + ::= { airIRmPmAlarmBits 50 } + +airIRmPmSensor12Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #12 defect (8550)." + ::= { airIRmPmAlarmBits 51 } + +airIRmPmSensor13Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #13 defect (8551)." + ::= { airIRmPmAlarmBits 52 } + +airIRmPmSensor14Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #14 defect (8552)." + ::= { airIRmPmAlarmBits 53 } + +airIRmPmSensor15Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #15 defect (8553)." + ::= { airIRmPmAlarmBits 54 } + +airIRmPmSensor16Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #16 defect (8554)." + ::= { airIRmPmAlarmBits 55 } + +airIRmPmSensor17Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #17 defect (8555)." + ::= { airIRmPmAlarmBits 56 } + +airIRmPmSensor18Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #18 defect (8556)" + ::= { airIRmPmAlarmBits 57 } + +airIRmPmSensor19Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #19 defect (8557)." + ::= { airIRmPmAlarmBits 58 } + +airIRmPmSensor20Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #20 defect (8558)." + ::= { airIRmPmAlarmBits 59 } + +airIRmPmSensor21Defect OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor #21 defect (8559)." + ::= { airIRmPmAlarmBits 60 } + +airIRmPmCompressor1Alarm OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor #1 alarm (8560)." + ::= { airIRmPmAlarmBits 61 } + +airIRmPmCompressor2Alarm OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor #2 alarm (8561)." + ::= { airIRmPmAlarmBits 62 } + +airIRmPmCompressor1LowPressure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor #1 low pressure (8562)." + ::= { airIRmPmAlarmBits 63 } + +airIRmPmCompressor2LowPressure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Compressor #2 low pressure (8563)." + ::= { airIRmPmAlarmBits 64 } + +airIRmPmReheat1Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Reheat #1 failure (8564)." + ::= { airIRmPmAlarmBits 65 } + +airIRmPmReheat2Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Reheat #2 failure (8565)." + ::= { airIRmPmAlarmBits 66 } + +airIRmPmReheat3Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Reheat #3 failure (8566)." + ::= { airIRmPmAlarmBits 67 } + +airIRmPmReheat4Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Reheat #4 failure (8567)." + ::= { airIRmPmAlarmBits 68 } + +airIRmPmDrycooler1Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler #1 failure (8568)." + ::= { airIRmPmAlarmBits 69 } + +airIRmPmDrycooler2Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler #2 failure (8569)." + ::= { airIRmPmAlarmBits 70 } + +airIRmPmDrycooler3Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler #3 failure (8570)." + ::= { airIRmPmAlarmBits 71 } + +airIRmPmDrycooler4Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Drycooler #4 failure (8571)." + ::= { airIRmPmAlarmBits 72 } + +airIRmPmPump1Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump #1 failure (8572)." + ::= { airIRmPmAlarmBits 73 } + +airIRmPmPump2Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump #2 failure (8573)." + ::= { airIRmPmAlarmBits 74 } + +airIRmPmPump3Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump #3 failure (8574)." + ::= { airIRmPmAlarmBits 75 } + +airIRmPmPump4Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Pump #4 failure (8575)." + ::= { airIRmPmAlarmBits 76 } + +airIRmPmHumidifier1Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #1 failure (8576)." + ::= { airIRmPmAlarmBits 77 } + +airIRmPmHumidifier2Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #2 failure (8577)." + ::= { airIRmPmAlarmBits 78 } + +airIRmPmHumidifier3Failure OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #3 failure (8578)." + ::= { airIRmPmAlarmBits 79 } + +airIRmPmHumidifier1Alarm5us OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #1 5us alarm (8579)." + ::= { airIRmPmAlarmBits 80 } + +airIRmPmHumidifier2Alarm5us OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #2 5us alarm (8580)." + ::= { airIRmPmAlarmBits 81 } + +airIRmPmHumidifier3Alarm5us OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #3 5us alarm (8581)." + ::= { airIRmPmAlarmBits 82 } + +airIRmPmHumidifier1Alarm20us OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #1 20us alarm (8582)." + ::= { airIRmPmAlarmBits 83 } + +airIRmPmHumidifier2Alarm20us OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #2 20us alarm (8583)." + ::= { airIRmPmAlarmBits 84 } + +airIRmPmHumidifier3Alarm20us OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Humidifier #3 20us alarm (8584)." + ::= { airIRmPmAlarmBits 85 } + +airIRmPmFan1Alarm OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan #1 alarm (8585)." + ::= { airIRmPmAlarmBits 86 } + +airIRmPmFan2Alarm OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan #2 alarm (8586)." + ::= { airIRmPmAlarmBits 87 } + +airIRmPmFan3Alarm OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Fan #3 alarm (8587)." + ::= { airIRmPmAlarmBits 88 } + +airIRmPmFilter1Clogged OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Filter #1 clogged (8588)." + ::= { airIRmPmAlarmBits 89 } + +airIRmPmFilter2Clogged OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Filter #2 clogged (8589)." + ::= { airIRmPmAlarmBits 90 } + +airIRmPmFilter3Clogged OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Filter #3 clogged (8590)." + ::= { airIRmPmAlarmBits 91 } + +airIRmPmAuxiliaryAlarm1 OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Auxiliary #1 alarm (8591)." + ::= { airIRmPmAlarmBits 92 } + +airIRmPmAuxiliaryAlarm2 OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Auxiliary #2 alarm (8592)." + ::= { airIRmPmAlarmBits 93 } + +airIRmPmAuxiliaryAlarm3 OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Auxiliary #3 alarm (8593)." + ::= { airIRmPmAlarmBits 94 } + +airIRmPmAuxiliaryAlarm4 OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Auxiliary #4 alarm (8594)." + ::= { airIRmPmAlarmBits 95 } + +airIRmPmAuxiliaryAlarm5 OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Auxiliary #5 alarm (8595)." + ::= { airIRmPmAlarmBits 96 } + +airIRmPmAuxiliaryAlarm6 OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Auxiliary #6 alarm (8596)." + ::= { airIRmPmAlarmBits 97 } + +airIRmPmAuxiliaryAlarm7 OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Auxiliary #7 alarm (8597)." + ::= { airIRmPmAlarmBits 98 } + +airIRmPmAuxiliaryAlarm8 OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Auxiliary #8 alarm (8598)." + ::= { airIRmPmAlarmBits 99 } + +airIRmPmAuxiliaryAlarm9 OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Auxiliary #9 alarm (8599)." + ::= { airIRmPmAlarmBits 100 } + +airIRmPmAuxiliaryAlarm10 OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Auxiliary #10 alarm (8600)." + ::= { airIRmPmAlarmBits 101 } + +airIRmPmHotGasHeatingAlarm OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Hot gas heating alarm (8601)." + ::= { airIRmPmAlarmBits 102 } + +airIRmPmEEV1PressureSensorError OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "EEV1 pressure sensor error (8602)." + ::= { airIRmPmAlarmBits 103 } + +airIRmPmEEV1TemperatureSensorError OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "EEV1 temperature sensor error (8603)." + ::= { airIRmPmAlarmBits 104 } + +airIRmPmEEV1StepperMotorError OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "EEV1 stepper motor error (8604)." + ::= { airIRmPmAlarmBits 105 } + +airIRmPmEEV2PressureSensorError OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "EEV2 pressure sensor error (8605)." + ::= { airIRmPmAlarmBits 106 } + +airIRmPmEEV2TemperatureSensorError OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "EEV2 temperature sensor error (8606)." + ::= { airIRmPmAlarmBits 107 } + +airIRmPmEEV2StepperMotorError OBJECT-TYPE + SYNTAX AirIRmAlarmState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "EEV2 stepper motor error (8607)." + ::= { airIRmPmAlarmBits 108 } + +-- airIRmPmMyZone + +airIRmPmMyZoneNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "My zone number (11700)." + ::= { airIRmPmMyZone 1 } + +airIRmPmMyZoneRoomTemperature OBJECT IDENTIFIER ::= { airIRmPmMyZone 2 } +airIRmPmMyZoneRoomTemperatureC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "My zone room temperature in tenths of degrees Celsius (11701)." + ::= { airIRmPmMyZoneRoomTemperature 1 } +airIRmPmMyZoneRoomTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "My zone room temperature in tenths of degrees Fahrenheit (11701)." + ::= { airIRmPmMyZoneRoomTemperature 2 } + +airIRmPmMyZoneRoomHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "My zone room humidity in tenths of %RH (11702)." + ::= { airIRmPmMyZone 3 } + +airIRmPmMyZoneSupplyTemperature OBJECT IDENTIFIER ::= { airIRmPmMyZone 4 } +airIRmPmMyZoneSupplyTemperatureC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "My zone supply temperature in tenths of degrees Celsius (11703)." + ::= { airIRmPmMyZoneSupplyTemperature 1 } +airIRmPmMyZoneSupplyTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "My zone supply temperature in tenths + of degrees Fahrenheit (11703)." + ::= { airIRmPmMyZoneSupplyTemperature 2 } + +airIRmPmMyZoneSupplyHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "My zone supply humidity in tenths of %RH (11704)." + ::= { airIRmPmMyZone 5 } + +airIRmPmMyZoneSequencingTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "My zone sequencing time in minutes (11705)." + ::= { airIRmPmMyZone 6 } + +airIRmPmMyZoneNumberOfErrorUnits OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of error units in my zone (11706)." + ::= { airIRmPmMyZone 7 } + +airIRmPmMyZoneEmergencyTemperature OBJECT IDENTIFIER ::= { airIRmPmMyZone 8 } +airIRmPmMyZoneEmergencyTemperatureC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "My zone emergency temperature in tenths of degrees Celsius (11707)." + ::= { airIRmPmMyZoneEmergencyTemperature 1 } +airIRmPmMyZoneEmergencyTemperatureF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "My zone emergency temperature in tenths + of degrees Fahrenheit (11707)." + ::= { airIRmPmMyZoneEmergencyTemperature 2 } + +airIRmPmMyZoneCWEnergySaveMode OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "My zone CW energy save mode (11708)." + ::= { airIRmPmMyZone 9 } + +-- airIRmPmGlobalZoneData + +airIRmPmGlobalZoneDataEmergencyOpMode OBJECT-TYPE + SYNTAX AirIRmActivityState + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Emergency operation mode (11800)." + ::= { airIRmPmGlobalZoneData 1 } + +-- End of AC InRoom + +-- Begining of airIRGen3 + +-- ****************************************************************** +--airIRG3 Ident Group +-- ****************************************************************** + +airIRG3IdentTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The ident table size." + ::= { airIRG3Ident 1 } + +AirIRG3IdentEntry ::= SEQUENCE { + airIRG3IdentIndex INTEGER, + airIRG3IdentName DisplayString, + airIRG3IdentLocation DisplayString, + airIRG3IdentModelNumber DisplayString, + airIRG3IdentSerialNumber DisplayString, + airIRG3IdentFirmwareRevision DisplayString, + airIRG3IdentHardwareRevision DisplayString, + airIRG3IdentManufactureDate DisplayString, + airIRG3IdentRDUSysOID OBJECT IDENTIFIER, + airIRG3IdentCMSysOID OBJECT IDENTIFIER, + airIRG3IdentGroupSysOID OBJECT IDENTIFIER + } + +airIRG3IdentTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3IdentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to get ident information of current RDU and its assigned CM's." + ::= { airIRG3Ident 2 } + +airIRG3IdentEntry OBJECT-TYPE + SYNTAX AirIRG3IdentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The ident table entry." + INDEX { airIRG3IdentIndex} + ::= { airIRG3IdentTable 1 } + +airIRG3IdentIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of ident table." + ::= { airIRG3IdentEntry 1 } + +airIRG3IdentName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the unit name." + ::= { airIRG3IdentEntry 2 } + +airIRG3IdentLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A character string identifying the unit location." + ::= { airIRG3IdentEntry 3 } + +airIRG3IdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the unit model number." + ::= { airIRG3IdentEntry 4 } + +airIRG3IdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the unit serial number." + ::= { airIRG3IdentEntry 5 } + +airIRG3IdentFirmwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the unit firmware version." + ::= { airIRG3IdentEntry 6 } + +airIRG3IdentHardwareRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the unit controller hardware revision." + ::= { airIRG3IdentEntry 7 } + +airIRG3IdentManufactureDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the unit manufacture date." + ::= { airIRG3IdentEntry 8 } + +airIRG3IdentRDUSysOID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID contains an OID path to the RDU data." + ::= { airIRG3IdentEntry 9 } + +airIRG3IdentCMSysOID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID contains an OID path to the cooling module data." + ::= { airIRG3IdentEntry 10 } + +airIRG3IdentGroupSysOID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID contains an OID path to the group data." + ::= { airIRG3IdentEntry 11 } + + + +-- ****************************************************************** +-- airIRG3 Group Status +-- ****************************************************************** + +airIRG3GroupTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group table size." + ::= { airIRG3Group 1 } + + +AirIRG3GroupStatusEntry ::= SEQUENCE { + airIRG3GroupStatusIndex INTEGER, + airIRG3GroupStatusCoolOutput INTEGER, + airIRG3GroupStatusCoolDemand INTEGER, + airIRG3GroupStatusAirFlowUS INTEGER, + airIRG3GroupStatusAirFlowMetric INTEGER, + airIRG3GroupStatusMaxRackInletTempUS INTEGER, + airIRG3GroupStatusMaxRackInletTempMetric INTEGER, + airIRG3GroupStatusMinRackInletTempUS INTEGER, + airIRG3GroupStatusMinRackInletTempMetric INTEGER, + airIRG3GroupStatusMaxReturnAirTempUS INTEGER, + airIRG3GroupStatusMaxReturnAirTempMetric INTEGER, + airIRG3GroupStatusMinReturnAirTempUS INTEGER, + airIRG3GroupStatusMinReturnAirTempMetric INTEGER, + airIRG3GroupStatusAvgSupplyTempUS INTEGER, + airIRG3GroupStatusAvgSupplyTempMetric INTEGER, + airIRG3GroupStatusAvgReturnTempUS INTEGER, + airIRG3GroupStatusAvgReturnTempMetric INTEGER, + airIRG3GroupStatusAvgFanSpeed INTEGER, + airIRG3GroupStatusAvgAirFlowUS INTEGER, + airIRG3GroupStatusAvgAirFlowMetric INTEGER, + airIRG3GroupStatusTotalAirFlowUS INTEGER, + airIRG3GroupStatusTotalAirFlowMetric INTEGER + } + +airIRG3GroupStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3GroupStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to get group status information." + ::= { airIRG3Group 2 } + +airIRG3GroupStatusEntry OBJECT-TYPE + SYNTAX AirIRG3GroupStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The group staus table entry." + INDEX { airIRG3GroupStatusIndex} + ::= { airIRG3GroupStatusTable 1 } + +airIRG3GroupStatusIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of group status table." + ::= { airIRG3GroupStatusEntry 1 } + +airIRG3GroupStatusCoolOutput OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group cooling output in tenths of kilowatts (kW). + Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 2 } + +airIRG3GroupStatusCoolDemand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group cooling demand in tenths of kilowatts (kW). + Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 3 } + +airIRG3GroupStatusAirFlowUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group air flow in cubic feet per minute (CFM). + Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 4 } + +airIRG3GroupStatusAirFlowMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group air flow in liters per second (L/s). + Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 5 } + +airIRG3GroupStatusMaxRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group maximum rack inlet temperature in tenths of + degrees Fahrenheit. Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 6 } + +airIRG3GroupStatusMaxRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group maximum rack inlet temperature in tenths of + degrees Celsius. Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 7 } + +airIRG3GroupStatusMinRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group minimum rack inlet temperature in tenths of + degrees Fahrenheit. Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 8 } + +airIRG3GroupStatusMinRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group minimum rack inlet temperature in tenths of + degrees Celsius. Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 9 } + +airIRG3GroupStatusMaxReturnAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group maximum return air temperature in tenths of + degrees Fahrenheit. Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 10 } + +airIRG3GroupStatusMaxReturnAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group maximum return air temperature in tenths of + degrees Celsius. Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 11 } + +airIRG3GroupStatusMinReturnAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group minimum return air temperature in tenths of + degrees Fahrenheit. Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 12 } + +airIRG3GroupStatusMinReturnAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group minimum return air temperature in tenths of + degrees Celsius. Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 13 } + +airIRG3GroupStatusAvgSupplyTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group average supply air temperature in tenths of + degrees Fahrenheit. Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 14 } + +airIRG3GroupStatusAvgSupplyTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group average supply air temperature in tenths of + degrees Celsius. Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 15 } + +airIRG3GroupStatusAvgReturnTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group average return air temperature in tenths of + degrees Fahrenheit. Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 16 } + +airIRG3GroupStatusAvgReturnTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group average return air temperature in tenths of + degrees Celsius. Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 17 } + +airIRG3GroupStatusAvgFanSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group average fan speed in revolutions per minute (RPM). + Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 18 } + +airIRG3GroupStatusAvgAirFlowUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group average air flow in cubic feet per minute (CFM). + Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 19 } + +airIRG3GroupStatusAvgAirFlowMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group average air flow in liters per second (L/s). + Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 20 } + +airIRG3GroupStatusTotalAirFlowUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group total air flow in cubic feet per minute (CFM). + Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 21 } + +airIRG3GroupStatusTotalAirFlowMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The group total air flow in liters per second (L/s). + Returns (-1) if not supported." + ::= { airIRG3GroupStatusEntry 22 } + + + +-- ****************************************************************** +--airIRG3 Group Setpoints +-- ****************************************************************** + +AirIRG3GroupSetpointsEntry ::= SEQUENCE { + airIRG3GroupSetpointsIndex INTEGER, + airIRG3GroupSetpointsCoolSetpointUS INTEGER, + airIRG3GroupSetpointsCoolSetpointMetric INTEGER, + airIRG3GroupSetpointsCoolDeadbandUS INTEGER, + airIRG3GroupSetpointsCoolDeadbandMetric INTEGER, + airIRG3GroupSetpointsFanSpeedPreference INTEGER, + airIRG3GroupSetpointsSupplyAirSetpointUS INTEGER, + airIRG3GroupSetpointsSupplyAirSetpointMetric INTEGER, + airIRG3GroupSetpointsAirFlowControl INTEGER, + airIRG3GroupSetpointsLightingOnTime INTEGER + } + +airIRG3GroupSetpointsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3GroupSetpointsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to access the group setpoints." + ::= { airIRG3Group 3 } + +airIRG3GroupSetpointsEntry OBJECT-TYPE + SYNTAX AirIRG3GroupSetpointsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The group setpoints table entry." + INDEX { airIRG3GroupSetpointsIndex} + ::= { airIRG3GroupSetpointsTable 1 } + +airIRG3GroupSetpointsIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of group setpoints table." + ::= { airIRG3GroupSetpointsEntry 1 } + +airIRG3GroupSetpointsCoolSetpointUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling setpoint in tenths of + degrees Fahrenheit." + ::= { airIRG3GroupSetpointsEntry 2 } + +airIRG3GroupSetpointsCoolSetpointMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling setpoint in tenths of + degrees Celsius." + ::= { airIRG3GroupSetpointsEntry 3 } + +airIRG3GroupSetpointsCoolDeadbandUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling deadband in tenths of + degrees Fahrenheit. Returns (-1) if not supported." + ::= { airIRG3GroupSetpointsEntry 4 } + +airIRG3GroupSetpointsCoolDeadbandMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group cooling deadband in tenths of + degrees Celsius. Returns (-1) if not supported." + ::= { airIRG3GroupSetpointsEntry 5 } + +airIRG3GroupSetpointsFanSpeedPreference OBJECT-TYPE + SYNTAX INTEGER { + low (1), + med-low (2), + med (3), + med-high (4), + high (5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group preferred fan speed setting." + ::= { airIRG3GroupSetpointsEntry 6 } + +airIRG3GroupSetpointsSupplyAirSetpointUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Fahrenheit." + ::= { airIRG3GroupSetpointsEntry 7 } + +airIRG3GroupSetpointsSupplyAirSetpointMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Group supply air setpoint in tenths of + degrees Celsius." + ::= { airIRG3GroupSetpointsEntry 8 } + +airIRG3GroupSetpointsAirFlowControl OBJECT-TYPE + SYNTAX INTEGER { + automatic (1), + manual (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group air flow control." + ::= { airIRG3GroupSetpointsEntry 9 } + +airIRG3GroupSetpointsLightingOnTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group lighting on time in minutes." + ::= { airIRG3GroupSetpointsEntry 10 } + + +-- ****************************************************************** +--airIRG3 Group Config +-- ****************************************************************** + +AirIRG3GroupConfigEntry ::= SEQUENCE { + airIRG3GroupConfigIndex INTEGER, + airIRG3GroupConfigNumberofCoolingUnits INTEGER, + airIRG3GroupConfigConfigurationType INTEGER, + airIRG3GroupConfigCapacityControlType INTEGER, + airIRG3GroupConfigFanSpeedControl INTEGER, + airIRG3GroupConfigCoolGainP INTEGER, + airIRG3GroupConfigCoolResetRateI INTEGER, + airIRG3GroupConfigCoolDerivativeD INTEGER, + airIRG3GroupConfigCoolPIDReset INTEGER, + airIRG3GroupConfigNumberofBackupUnits INTEGER, + airIRG3GroupConfigRuntimeBalancingEnable INTEGER, + airIRG3GroupConfigLoadAssistEnable INTEGER + } + +airIRG3GroupConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3GroupConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to access group configuration table." + ::= { airIRG3Group 4 } + +airIRG3GroupConfigEntry OBJECT-TYPE + SYNTAX AirIRG3GroupConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The group config table entry." + INDEX { airIRG3GroupConfigIndex} + ::= { airIRG3GroupConfigTable 1 } + +airIRG3GroupConfigIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of group config table." + ::= { airIRG3GroupConfigEntry 1 } + +airIRG3GroupConfigNumberofCoolingUnits OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of cooling units." + ::= { airIRG3GroupConfigEntry 2 } + +airIRG3GroupConfigConfigurationType OBJECT-TYPE + SYNTAX INTEGER { + racs (1), + spot (2), + in-row (3), + hacs (4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group configuration type. + The spot configuration type is not supported. + Returns (-1) if not supported." + ::= { airIRG3GroupConfigEntry 3 } + +airIRG3GroupConfigCapacityControlType OBJECT-TYPE + SYNTAX INTEGER { + discrete (1), + proportional (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group capacity control. Returns (-1) if not supported." + ::= { airIRG3GroupConfigEntry 4 } + +airIRG3GroupConfigFanSpeedControl OBJECT-TYPE + SYNTAX INTEGER { + automatic (1), + manual (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The group fan speed control." + ::= { airIRG3GroupConfigEntry 5 } + +airIRG3GroupConfigCoolGainP OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The gain component of the PID in hundredths." + ::= { airIRG3GroupConfigEntry 6 } + +airIRG3GroupConfigCoolResetRateI OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The integral component of the PID in hundredths." + ::= { airIRG3GroupConfigEntry 7 } + +airIRG3GroupConfigCoolDerivativeD OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The derivative component of the PID in hundredths." + ::= { airIRG3GroupConfigEntry 8 } + +airIRG3GroupConfigCoolPIDReset OBJECT-TYPE + SYNTAX INTEGER { + readBack (1), + reset (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Will reset the PID coefficients back to the factory defaults. + Readback is not supported, returns -1." + ::= { airIRG3GroupConfigEntry 9 } + +airIRG3GroupConfigNumberofBackupUnits OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of backup units." + ::= { airIRG3GroupConfigEntry 10 } + +airIRG3GroupConfigRuntimeBalancingEnable OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable runtime balancing feature." + ::= { airIRG3GroupConfigEntry 11 } + +airIRG3GroupConfigLoadAssistEnable OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable load assist feature." + ::= { airIRG3GroupConfigEntry 12 } + + +-- *************************************** +-- airIRG3 Alarm Status +-- *************************************** + +airIRG3AlarmsTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of active alarms in the airIRG3AlarmsTable." + ::= { airIRG3Alarms 1 } + +AirIRG3AlarmsEntry ::= SEQUENCE { + airIRG3AlarmsIndex INTEGER, + airIRG3AlarmsEventCode INTEGER, + airIRG3AlarmsDescription DisplayString + } + +airIRG3AlarmsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3AlarmsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Table of active alarms for the device." + ::= { airIRG3Alarms 2 } + +airIRG3AlarmsEntry OBJECT-TYPE + SYNTAX AirIRG3AlarmsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Alarms specification" + INDEX { airIRG3AlarmsIndex } + ::= { airIRG3AlarmsTable 1 } + +airIRG3AlarmsIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Alarm index." + ::= { airIRG3AlarmsEntry 1 } + +airIRG3AlarmsEventCode OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Event Code for the alarm. Returns (-1) if not supported." + ::= { airIRG3AlarmsEntry 2 } + +airIRG3AlarmsDescription OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..64)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of the alarm. Returns (-1) if not supported." + ::= { airIRG3AlarmsEntry 3 } + +-- *************************************** +-- airIRG3 RDU Status +-- *************************************** + +airIRG3RDUTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU table size." + ::= { airIRG3RDU 1 } + + +AirIRG3RDUStatusEntry ::= SEQUENCE { + airIRG3RDUStatusDeviceIndex INTEGER, + airIRG3RDUID DisplayString, + airIRG3RDUStatusOnReadyStandby INTEGER, + airIRG3RDUStatusOperatingMode INTEGER, + airIRG3RDUStatusLeadPump INTEGER, + airIRG3RDUStatusStartupDelay INTEGER, + airIRG3RDUStatusPumpChangeOverInterval INTEGER, + airIRG3RDUStatusStopOnLeakDetect INTEGER, + airIRG3RDUStatusPowerSource INTEGER, + airIRG3RDUStatusTotalRDUOutputPower INTEGER, + airIRG3RDUStatusInletWaterTempUS INTEGER, + airIRG3RDUStatusInletWaterTempMetric INTEGER, + airIRG3RDUStatusOutletWaterTempUS INTEGER, + airIRG3RDUStatusOutletWaterTempMetric INTEGER, + airIRG3RDUStatusCondenserSaturationTempUS INTEGER, + airIRG3RDUStatusCondenserSaturationTempMetric INTEGER, + airIRG3RDUStatusDewPointTempUS INTEGER, + airIRG3RDUStatusDewPointTempMetric INTEGER, + airIRG3RDUStatusPumpOutletTempUS INTEGER, + airIRG3RDUStatusPumpOutletTempMetric INTEGER, + airIRG3RDUStatusSubcoolerOutletTempUS INTEGER, + airIRG3RDUStatusSubcoolerOutletTempMetric INTEGER, + airIRG3RDUStatusCondenserOutletTempUS INTEGER, + airIRG3RDUStatusCondenserOutletTempMetric INTEGER, + airIRG3RDUStatusCondenserInletTempUS INTEGER, + airIRG3RDUStatusCondenserInletTempMetric INTEGER, + airIRG3RDUStatusCondenserOutletPressureUS INTEGER, + airIRG3RDUStatusCondenserOutletPressureMetric INTEGER, + airIRG3RDUStatusPump1HeadPressureUS INTEGER, + airIRG3RDUStatusPump1HeadPressureMetric INTEGER, + airIRG3RDUStatusPump2HeadPressureUS INTEGER, + airIRG3RDUStatusPump2HeadPressureMetric INTEGER, + airIRG3RDUStatusPump1Speed INTEGER, + airIRG3RDUStatusPump2Speed INTEGER, + airIRG3RDUStatusCWValvePosition INTEGER, + airIRG3RDUStatusReceiverLiquidLevel INTEGER, + airIRG3RDUStatusDCPowerSupply1Current INTEGER, + airIRG3RDUStatusDCPowerSupply2Current INTEGER, + airIRG3RDUStatusTotalDCPowerSupplyCurrent INTEGER, + airIRG3RDUStatusInputState INTEGER, + airIRG3RDUStatusOutputState INTEGER, + airIRG3RDUStatusByPassValvePosition INTEGER, + airIRG3RDUStatusRefrigerantLeakDetector INTEGER + } + +airIRG3RDUStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3RDUStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to access RDU status table." + ::= { airIRG3RDU 2 } + +airIRG3RDUStatusEntry OBJECT-TYPE + SYNTAX AirIRG3RDUStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The RDU status table entry." + INDEX { airIRG3RDUStatusDeviceIndex} + ::= { airIRG3RDUStatusTable 1 } + +airIRG3RDUStatusDeviceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of RDU status table." + ::= { airIRG3RDUStatusEntry 1 } + + +airIRG3RDUID OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current RDU ID (1 to F). + Configured RDU only shall display ID, else return -1. " + ::= { airIRG3RDUStatusEntry 2 } + + +airIRG3RDUStatusOnReadyStandby OBJECT-TYPE + SYNTAX INTEGER { + standby (1), + ready (2), + on (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU current status." + ::= { airIRG3RDUStatusEntry 3 } + + +airIRG3RDUStatusOperatingMode OBJECT-TYPE + SYNTAX INTEGER { + standby (1), + ready (2), + on (3), + stop (4), + maintenancemode (5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU actual operating mode." + ::= { airIRG3RDUStatusEntry 4 } + + +airIRG3RDUStatusLeadPump OBJECT-TYPE + SYNTAX INTEGER { + pump1 (1), + pump2 (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU lead pump." + ::= { airIRG3RDUStatusEntry 5 } + + +airIRG3RDUStatusStartupDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU start up delay in seconds." + ::= { airIRG3RDUStatusEntry 6 } + + +airIRG3RDUStatusPumpChangeOverInterval OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU pump change over interval in days." + ::= { airIRG3RDUStatusEntry 7 } + + +airIRG3RDUStatusStopOnLeakDetect OBJECT-TYPE + SYNTAX INTEGER { + no (1), + yes (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU status of stop on leak detect." + ::= { airIRG3RDUStatusEntry 8 } + + +airIRG3RDUStatusPowerSource OBJECT-TYPE + SYNTAX INTEGER { + singleFeed (1), + dualFeed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU power source status." + ::= { airIRG3RDUStatusEntry 9 } + + +airIRG3RDUStatusTotalRDUOutputPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU output power in tenths of kilowatts (kW)." + ::= { airIRG3RDUStatusEntry 10 } + + +airIRG3RDUStatusInletWaterTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU inlet water temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3RDUStatusEntry 11 } + + +airIRG3RDUStatusInletWaterTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU inlet water temperature in tenths of + degrees Celsius." + ::= { airIRG3RDUStatusEntry 12 } + + +airIRG3RDUStatusOutletWaterTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU outlet water temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3RDUStatusEntry 13 } + + +airIRG3RDUStatusOutletWaterTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU outlet water temperature in tenths of + degrees Celsius." + ::= { airIRG3RDUStatusEntry 14 } + + +airIRG3RDUStatusCondenserSaturationTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU condenser saturation temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3RDUStatusEntry 15 } + + +airIRG3RDUStatusCondenserSaturationTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU condenser saturation temperature in tenths of + degrees Celsius." + ::= { airIRG3RDUStatusEntry 16 } + + +airIRG3RDUStatusDewPointTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU dew point temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3RDUStatusEntry 17 } + + +airIRG3RDUStatusDewPointTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU dew point temperature in tenths of + degrees Celsius." + ::= { airIRG3RDUStatusEntry 18 } + + +airIRG3RDUStatusPumpOutletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU pump outlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3RDUStatusEntry 19 } + + +airIRG3RDUStatusPumpOutletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU pump outlet temperature in tenths of + degrees Celsius." + ::= { airIRG3RDUStatusEntry 20 } + + +airIRG3RDUStatusSubcoolerOutletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU sub cooler outlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3RDUStatusEntry 21 } + + +airIRG3RDUStatusSubcoolerOutletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU sub cooler outlet temperature in tenths of + degrees Celsius." + ::= { airIRG3RDUStatusEntry 22 } + + +airIRG3RDUStatusCondenserOutletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU condenser outlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3RDUStatusEntry 23 } + + +airIRG3RDUStatusCondenserOutletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU condenser outlet temperature in tenths of + degrees Celsius." + ::= { airIRG3RDUStatusEntry 24 } + + +airIRG3RDUStatusCondenserInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU condenser inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3RDUStatusEntry 25 } + + +airIRG3RDUStatusCondenserInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU condenser inlet temperature in tenths of + degrees Celsius." + ::= { airIRG3RDUStatusEntry 26 } + + +airIRG3RDUStatusCondenserOutletPressureUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU condenser outlet pressure in + pounds per square inch (PSI)." + ::= { airIRG3RDUStatusEntry 27 } + +airIRG3RDUStatusCondenserOutletPressureMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU condenser outlet pressure in kiloPascals (KPa)." + ::= { airIRG3RDUStatusEntry 28 } + + +airIRG3RDUStatusPump1HeadPressureUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU Pump 1 head pressure in pounds per square inch (PSI)." + ::= { airIRG3RDUStatusEntry 29 } + +airIRG3RDUStatusPump1HeadPressureMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU Pump 1 head pressure in kiloPascals (KPa)." + ::= { airIRG3RDUStatusEntry 30 } + +airIRG3RDUStatusPump2HeadPressureUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU Pump 2 head pressure in pounds per square inch (PSI)." + ::= { airIRG3RDUStatusEntry 31 } + +airIRG3RDUStatusPump2HeadPressureMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU Pump 2 head pressure in kiloPascals (KPa)." + ::= { airIRG3RDUStatusEntry 32 } + +airIRG3RDUStatusPump1Speed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU Pump 1 speed in revolutions per minute (RPM)." + ::= { airIRG3RDUStatusEntry 33 } + + +airIRG3RDUStatusPump2Speed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU Pump 2 speed in revolutions per minute (RPM)." + ::= { airIRG3RDUStatusEntry 34 } + + +airIRG3RDUStatusCWValvePosition OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU CW Valve position in % open" + ::= { airIRG3RDUStatusEntry 35 } + + +airIRG3RDUStatusReceiverLiquidLevel OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU receiver liquid level in % Full" + ::= { airIRG3RDUStatusEntry 36 } + + +airIRG3RDUStatusDCPowerSupply1Current OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU DC Power Supply 1 Current in Amps" + ::= { airIRG3RDUStatusEntry 37 } + + +airIRG3RDUStatusDCPowerSupply2Current OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU DC Power Supply 2 Current in Amps" + ::= { airIRG3RDUStatusEntry 38 } + + +airIRG3RDUStatusTotalDCPowerSupplyCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU Total DC Power Supply Current in Amps" + ::= { airIRG3RDUStatusEntry 39 } + + +airIRG3RDUStatusInputState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU Input state." + ::= { airIRG3RDUStatusEntry 40 } + + +airIRG3RDUStatusOutputState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU Output state" + ::= { airIRG3RDUStatusEntry 41 } + +airIRG3RDUStatusByPassValvePosition OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU By Pass Valve position in % open" + ::= { airIRG3RDUStatusEntry 42 } + +airIRG3RDUStatusRefrigerantLeakDetector OBJECT-TYPE + SYNTAX INTEGER { + suspended (1), + calibrating (2), + operating (3), + disabled (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU refrigerant leak detector status." + ::= { airIRG3RDUStatusEntry 43 } + + +-- *************************************** +-- airIRG3 RDU Run Hours +-- *************************************** + +AirIRG3RDURunHoursEntry ::= SEQUENCE { + airIRG3RDURunHoursDeviceIndex INTEGER, + airIRG3RDURunHoursRDUID DisplayString, + airIRG3RDURunHoursPump1 INTEGER, + airIRG3RDURunHoursPump2 INTEGER, + airIRG3RDURunHoursPowerSupply1 INTEGER, + airIRG3RDURunHoursPowerSupply2 INTEGER + } + +airIRG3RDURunHoursTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3RDURunHoursEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to access RDU run hours table." + ::= { airIRG3RDU 3 } + +airIRG3RDURunHoursEntry OBJECT-TYPE + SYNTAX AirIRG3RDURunHoursEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The RDU run hours table entry." + INDEX { airIRG3RDURunHoursDeviceIndex} + ::= { airIRG3RDURunHoursTable 1 } + +airIRG3RDURunHoursDeviceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of RDU run hours table." + ::= { airIRG3RDURunHoursEntry 1 } + +airIRG3RDURunHoursRDUID OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current RDU ID (1 to F). + Configured RDU only shall display ID, else return -1. " + ::= { airIRG3RDURunHoursEntry 2 } + +airIRG3RDURunHoursPump1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU run hours of Pump 1." + ::= { airIRG3RDURunHoursEntry 3 } + +airIRG3RDURunHoursPump2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU run hours of Pump 2." + ::= { airIRG3RDURunHoursEntry 4 } + +airIRG3RDURunHoursPowerSupply1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU run hours of power supply 1." + ::= { airIRG3RDURunHoursEntry 5 } + +airIRG3RDURunHoursPowerSupply2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The RDU run hours of power supply 2." + ::= { airIRG3RDURunHoursEntry 6 } + + +-- *************************************** +-- airIRG3 RDU Service Intervals +-- *************************************** + +AirIRG3RDUServiceIntervalsEntry ::= SEQUENCE { + airIRG3RDUServiceIntervalsDeviceIndex INTEGER, + airIRG3RDUServiceIntervalsRDUID DisplayString, + airIRG3RDUServiceIntervalsAirFilterInterval INTEGER, + airIRG3RDUServiceIntervalsAirFilterAlarm INTEGER + } + +airIRG3RDUServiceIntervalsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3RDUServiceIntervalsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to access RDU service intervals table." + ::= { airIRG3RDU 4 } + +airIRG3RDUServiceIntervalsEntry OBJECT-TYPE + SYNTAX AirIRG3RDUServiceIntervalsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The service interval table entry." + INDEX { airIRG3RDUServiceIntervalsDeviceIndex} + ::= { airIRG3RDUServiceIntervalsTable 1 } + +airIRG3RDUServiceIntervalsDeviceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of service interval table." + ::= { airIRG3RDUServiceIntervalsEntry 1 } + +airIRG3RDUServiceIntervalsRDUID OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current RDU ID (1 to F). + Configured RDU only shall display ID, else return -1. " + ::= { airIRG3RDUServiceIntervalsEntry 2 } + +airIRG3RDUServiceIntervalsAirFilterInterval OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The RDU service interval for air filter in hours. + Returns -1 if not supported." + ::= { airIRG3RDUServiceIntervalsEntry 3 } + + +airIRG3RDUServiceIntervalsAirFilterAlarm OBJECT-TYPE + SYNTAX INTEGER { + enable (1), + disable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The RDU service interval air filter alarm status. + Returns -1 if not supported." + ::= { airIRG3RDUServiceIntervalsEntry 4 } + + + +-- ******************************************* +-- airIRG3 RDU Thresholds +-- Currently there are no thresholds for RDU +-- ******************************************* + +AirIRG3RDUThresholdsEntry ::= SEQUENCE { + airIRG3RDUThresholdsDeviceIndex INTEGER, + airIRG3RDUThresholdsRDUID DisplayString, + airIRG3RDUThresholdsEnteringFluidTempHighUS INTEGER, + airIRG3RDUThresholdsEnteringFluidTempHighMetric INTEGER + } + +airIRG3RDUThresholdsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3RDUThresholdsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to access RDU thresholds table." + ::= { airIRG3RDU 5 } + +airIRG3RDUThresholdsEntry OBJECT-TYPE + SYNTAX AirIRG3RDUThresholdsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The RDU thresholds table entry." + INDEX { airIRG3RDUThresholdsDeviceIndex} + ::= { airIRG3RDUThresholdsTable 1 } + +airIRG3RDUThresholdsDeviceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of RDU thresholds table." + ::= { airIRG3RDUThresholdsEntry 1 } + +airIRG3RDUThresholdsRDUID OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current RDU ID (1 to F). + Configured RDU only shall display ID, else return -1. " + ::= { airIRG3RDUThresholdsEntry 2 } + +airIRG3RDUThresholdsEnteringFluidTempHighUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The RDU threshold for entering fluid temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3RDUThresholdsEntry 3 } + + +airIRG3RDUThresholdsEnteringFluidTempHighMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The RDU threshold for entering fluid temperature in tenths of + degrees Celsius." + ::= { airIRG3RDUThresholdsEntry 4 } + + +-- *************************************** +-- airIRG3 RDU Setpoints +-- *************************************** + +AirIRG3RDUSetpointsEntry ::= SEQUENCE { + airIRG3RDUSetpointsDeviceIndex INTEGER + } + +airIRG3RDUSetpointsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3RDUSetpointsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to access RDU set points table." + ::= { airIRG3RDU 6 } + +airIRG3RDUSetpointsEntry OBJECT-TYPE + SYNTAX AirIRG3RDUSetpointsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The RDU set points table entry." + INDEX { airIRG3RDUSetpointsDeviceIndex} + ::= { airIRG3RDUSetpointsTable 1 } + +airIRG3RDUSetpointsDeviceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of RDU set points table." + ::= { airIRG3RDUSetpointsEntry 1 } + + + +-- *************************************** +-- airIRG3 RDU Config +-- *************************************** + +AirIRG3RDUConfigEntry ::= SEQUENCE { + airIRG3RDUConfigDeviceIndex INTEGER, + airIRG3RDUConfigRDUID DisplayString, + airIRG3RDUConfigStopOnLeakDetect INTEGER, + airIRG3RDUConfigStartupDelay INTEGER, + airIRG3RDUConfigPumpChangeOverInterval INTEGER, + airIRG3RDUConfigPowerSource INTEGER, + airIRG3RDUConfigOutputSource INTEGER, + airIRG3RDUConfigInputNormalState INTEGER, + airIRG3RDUConfigOutputNormalState INTEGER, + airIRG3RDUConfigByPassValveEnabled INTEGER, + airIRG3RDUConfigRefrigerantLeakDetectorEnabled INTEGER, + airIRG3RDUConfigCalibrateRefrigerantLeakDetector INTEGER, + airIRG3RDUConfigOnReadyStandby INTEGER + } + +airIRG3RDUConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3RDUConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to access RDU configuration table." + ::= { airIRG3RDU 7 } + +airIRG3RDUConfigEntry OBJECT-TYPE + SYNTAX AirIRG3RDUConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The RDU configuration table entry." + INDEX { airIRG3RDUConfigDeviceIndex} + ::= { airIRG3RDUConfigTable 1 } + +airIRG3RDUConfigDeviceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of RDU configuration table." + ::= { airIRG3RDUConfigEntry 1 } + +airIRG3RDUConfigRDUID OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current RDU ID (1 to F). + Configured RDU only shall display ID, else return -1. " + ::= { airIRG3RDUConfigEntry 2 } + +airIRG3RDUConfigStopOnLeakDetect OBJECT-TYPE + SYNTAX INTEGER { + no (1), + yes (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The RDU stop on leak detect set." + ::= { airIRG3RDUConfigEntry 3 } + + +airIRG3RDUConfigStartupDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The RDU start up delay in seconds." + ::= { airIRG3RDUConfigEntry 4 } + + +airIRG3RDUConfigPumpChangeOverInterval OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The RDU pump change over interval in days." + ::= { airIRG3RDUConfigEntry 5 } + + +airIRG3RDUConfigPowerSource OBJECT-TYPE + SYNTAX INTEGER { + singleFeed (1), + dualFeed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The RDU power source." + ::= { airIRG3RDUConfigEntry 6 } + + +airIRG3RDUConfigOutputSource OBJECT-TYPE + SYNTAX INTEGER { + anyalarm (1), + onlycriticalalarms (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The RDU output source." + ::= { airIRG3RDUConfigEntry 7 } + + +airIRG3RDUConfigInputNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The RDU Input Normal State." + ::= { airIRG3RDUConfigEntry 8 } + + +airIRG3RDUConfigOutputNormalState OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The RDU Output Normal State." + ::= { airIRG3RDUConfigEntry 9 } + + +airIRG3RDUConfigByPassValveEnabled OBJECT-TYPE + SYNTAX INTEGER { + no (1), + yes (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The RDU By Pass Valve Enabled State." + ::= { airIRG3RDUConfigEntry 10 } + +airIRG3RDUConfigRefrigerantLeakDetectorEnabled OBJECT-TYPE + SYNTAX INTEGER { + no (1), + yes (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The RDU Refrigerant Leak Detector Enabled State." + ::= { airIRG3RDUConfigEntry 11 } + +airIRG3RDUConfigCalibrateRefrigerantLeakDetector OBJECT-TYPE + SYNTAX INTEGER { + no (1), + yes (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This parameter allows to calibrate the RDU Refrigerant Leak Detector and is write only. + The read returns -1. Only 'yes' is supported." + ::= { airIRG3RDUConfigEntry 12 } + +airIRG3RDUConfigOnReadyStandby OBJECT-TYPE + SYNTAX INTEGER { + standby (1), + ready (2), + on (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This parameter allows to configure RDU on/standby parameter. + Ready is currently not supported. If unsupported returns -1. " + ::= { airIRG3RDUConfigEntry 13 } + + +-- *************************************** +-- airIRG3 CMStatus +-- *************************************** + +airIRG3CMTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The cooling module table size." + ::= { airIRG3CM 1 } + + +AirIRG3CMStatusEntry ::= SEQUENCE { + airIRG3CMStatusDeviceIndex INTEGER, + airIRG3CMStatusCMID DisplayString, + airIRG3CMStatusOperatingMode INTEGER, + airIRG3CMStatusUnitType INTEGER, + airIRG3CMStatusRackInletTempUS INTEGER, + airIRG3CMStatusRackInletTempMetric INTEGER, + airIRG3CMStatusReturnAirTempUS INTEGER, + airIRG3CMStatusReturnAirTempMetric INTEGER, + airIRG3CMStatusLiquidTempUS INTEGER, + airIRG3CMStatusLiquidTempMetric INTEGER, + airIRG3CMStatusVaporTempUS INTEGER, + airIRG3CMStatusVaporTempMetric INTEGER, + airIRG3CMStatusEvaporatorTempUS INTEGER, + airIRG3CMStatusEvaporatorTempMetric INTEGER, + airIRG3CMStatusLiquidInletPressureUS INTEGER, + airIRG3CMStatusLiquidInletPressureMetric INTEGER, + airIRG3CMStatusVaporOutletPressureUS INTEGER, + airIRG3CMStatusVaporOutletPressureMetric INTEGER, + airIRG3CMStatusExpansionValvePosition INTEGER, + airIRG3CMStatusEPRValvePosition INTEGER, + airIRG3CMStatusLocalDisplayOnOffEnabled INTEGER, + airIRG3CMStatusAverageFanSpeed INTEGER + } + +airIRG3CMStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3CMStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to access CM status table." + ::= { airIRG3CM 2 } + +airIRG3CMStatusEntry OBJECT-TYPE + SYNTAX AirIRG3CMStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The CM status table entry." + INDEX { airIRG3CMStatusDeviceIndex} + ::= { airIRG3CMStatusTable 1 } + +airIRG3CMStatusDeviceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of CM status table." + ::= { airIRG3CMStatusEntry 1 } + +airIRG3CMStatusCMID OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM ID (RDU Number - Group Number - CM Unit Number)." + ::= { airIRG3CMStatusEntry 2 } + +airIRG3CMStatusOperatingMode OBJECT-TYPE + SYNTAX INTEGER { + standBy (1), + on (2), + idle (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current operating mode of the CM." + ::= { airIRG3CMStatusEntry 3 } + + +airIRG3CMStatusUnitType OBJECT-TYPE + SYNTAX INTEGER{ + unconfigured (1), + oa (2), + ra (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current CM unit type." + ::= { airIRG3CMStatusEntry 4 } + + +airIRG3CMStatusRackInletTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3CMStatusEntry 5 } + + +airIRG3CMStatusRackInletTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRG3CMStatusEntry 6 } + + +airIRG3CMStatusReturnAirTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM return air temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3CMStatusEntry 7 } + + +airIRG3CMStatusReturnAirTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM return air temperature in tenths of + degrees Celsius." + ::= { airIRG3CMStatusEntry 8 } + + +airIRG3CMStatusLiquidTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM liquid temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3CMStatusEntry 9 } + + +airIRG3CMStatusLiquidTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM liquid temperature in tenths of + degrees Celsius." + ::= { airIRG3CMStatusEntry 10 } + + +airIRG3CMStatusVaporTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM vapor temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3CMStatusEntry 11 } + + +airIRG3CMStatusVaporTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM vapor temperature in tenths of + degrees Celsius." + ::= { airIRG3CMStatusEntry 12 } + + +airIRG3CMStatusEvaporatorTempUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM saturation temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3CMStatusEntry 13 } + + +airIRG3CMStatusEvaporatorTempMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM saturation temperature in tenths of + degrees Celsius." + ::= { airIRG3CMStatusEntry 14 } + +airIRG3CMStatusLiquidInletPressureUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM Liquid Inlet pressure in pounds per square inch (PSI)." + ::= { airIRG3CMStatusEntry 15 } + +airIRG3CMStatusLiquidInletPressureMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM Liquid Inlet pressure in kiloPascals (kPa)." + ::= { airIRG3CMStatusEntry 16 } + +airIRG3CMStatusVaporOutletPressureUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM Vapor Outlet pressure in pounds per square inch (PSI)." + ::= { airIRG3CMStatusEntry 17 } + +airIRG3CMStatusVaporOutletPressureMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM Vapor Outlet pressure in kiloPascals (kPa)." + ::= { airIRG3CMStatusEntry 18 } + +airIRG3CMStatusExpansionValvePosition OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM expansion valve position in % open" + ::= { airIRG3CMStatusEntry 19 } + + +airIRG3CMStatusEPRValvePosition OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM Evaporator Pressure Regulator Valve Position + in tenths of percent open" + ::= { airIRG3CMStatusEntry 20 } + + +airIRG3CMStatusLocalDisplayOnOffEnabled OBJECT-TYPE + SYNTAX INTEGER { + no (1), + yes (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the on/off control on the CM local display." + ::= { airIRG3CMStatusEntry 21 } + + +airIRG3CMStatusAverageFanSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM Average Fan Speed." + ::= { airIRG3CMStatusEntry 22 } + + +-- *************************************** +-- airIRG3 CM Run Hours +-- *************************************** + +AirIRG3CMRunHoursEntry ::= SEQUENCE { + airIRG3CMRunHoursDeviceIndex INTEGER, + airIRG3CMRunHoursCMID DisplayString, + airIRG3CMRunHoursFan1 INTEGER, + airIRG3CMRunHoursFan2 INTEGER, + airIRG3CMRunHoursFan3 INTEGER, + airIRG3CMRunHoursFan4 INTEGER, + airIRG3CMRunHoursFan5 INTEGER, + airIRG3CMRunHoursAirFilter INTEGER + } + +airIRG3CMRunHoursTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3CMRunHoursEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to access CM run hours table." + ::= { airIRG3CM 3 } + +airIRG3CMRunHoursEntry OBJECT-TYPE + SYNTAX AirIRG3CMRunHoursEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The CM run hours table entry." + INDEX { airIRG3CMRunHoursDeviceIndex} + ::= { airIRG3CMRunHoursTable 1 } + +airIRG3CMRunHoursDeviceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of CM run hours table." + ::= { airIRG3CMRunHoursEntry 1 } + +airIRG3CMRunHoursCMID OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM ID (RDU Number - Group Number - CM Unit Number)." + ::= { airIRG3CMRunHoursEntry 2 } + +airIRG3CMRunHoursFan1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM run hours for Fan1. + Returns (-1) if not appilcable." + ::= { airIRG3CMRunHoursEntry 3 } + +airIRG3CMRunHoursFan2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM run hours for Fan2. + Returns (-1) if not appilcable." + ::= { airIRG3CMRunHoursEntry 4 } + +airIRG3CMRunHoursFan3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM run hours for Fan3. + Returns (-1) if not appilcable." + ::= { airIRG3CMRunHoursEntry 5 } + +airIRG3CMRunHoursFan4 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM run hours for Fan4. + Returns (-1) if not appilcable." + ::= { airIRG3CMRunHoursEntry 6 } + +airIRG3CMRunHoursFan5 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM run hours for Fan5. + Returns (-1) if not appilcable." + ::= { airIRG3CMRunHoursEntry 7 } + +airIRG3CMRunHoursAirFilter OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM run hours for air filter." + ::= { airIRG3CMRunHoursEntry 8 } + + + +-- *************************************** +-- airIRG3 CM Service Intervals +-- *************************************** + +AirIRG3CMServiceIntervalsEntry ::= SEQUENCE { + airIRG3CMServiceIntervalsDeviceIndex INTEGER, + airIRG3CMServiceIntervalsCMID DisplayString, + airIRG3CMServiceIntervalsAirFilterInterval INTEGER, + airIRG3CMServiceIntervalsAirFilterAlarm INTEGER + } + +airIRG3CMServiceIntervalsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3CMServiceIntervalsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to access CM service intervals table." + ::= { airIRG3CM 4 } + +airIRG3CMServiceIntervalsEntry OBJECT-TYPE + SYNTAX AirIRG3CMServiceIntervalsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The CM service interval table entry." + INDEX { airIRG3CMServiceIntervalsDeviceIndex} + ::= { airIRG3CMServiceIntervalsTable 1 } + +airIRG3CMServiceIntervalsDeviceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of CM service intervals table." + ::= { airIRG3CMServiceIntervalsEntry 1 } + +airIRG3CMServiceIntervalsCMID OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM ID (RDU Number - Group Number - CM Unit Number)." + ::= { airIRG3CMServiceIntervalsEntry 2 } + +airIRG3CMServiceIntervalsAirFilterInterval OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The CM service interval for air filter in weeks. + Supported only for RA. Returns -1 if not supported." + ::= { airIRG3CMServiceIntervalsEntry 3 } + +airIRG3CMServiceIntervalsAirFilterAlarm OBJECT-TYPE + SYNTAX INTEGER{ + disable (1), + enable (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The CM service interval air filter alarm status. + Supported only for RA. Returns -1 if not supported." + ::= { airIRG3CMServiceIntervalsEntry 4 } + + +-- *************************************** +-- airIRG3 CM Thresholds +-- *************************************** + +AirIRG3CMThresholdsEntry ::= SEQUENCE { + airIRG3CMThresholdsDeviceIndex INTEGER, + airIRG3CMThresholdsCMID DisplayString, + airIRG3CMThresholdsRackInletTempHighUS INTEGER, + airIRG3CMThresholdsRackInletTempHighMetric INTEGER, + airIRG3CMThresholdsSupplyAirTempHighUS INTEGER, + airIRG3CMThresholdsSupplyAirTempHighMetric INTEGER, + airIRG3CMThresholdsReturnAirTempHighUS INTEGER, + airIRG3CMThresholdsReturnAirTempHighMetric INTEGER + } + +airIRG3CMThresholdsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3CMThresholdsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to access CM thresholds table." + ::= { airIRG3CM 5 } + +airIRG3CMThresholdsEntry OBJECT-TYPE + SYNTAX AirIRG3CMThresholdsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The CM thresholds table entry." + INDEX { airIRG3CMThresholdsDeviceIndex} + ::= { airIRG3CMThresholdsTable 1 } + +airIRG3CMThresholdsDeviceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index for CM thresholds table." + ::= { airIRG3CMThresholdsEntry 1 } + +airIRG3CMThresholdsCMID OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM ID (RDU Number - Group Number - CM Unit Number)." + ::= { airIRG3CMThresholdsEntry 2 } + +airIRG3CMThresholdsRackInletTempHighUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The CM high threshold for rack inlet temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3CMThresholdsEntry 3 } + + +airIRG3CMThresholdsRackInletTempHighMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The CM high threshold for rack inlet temperature in tenths of + degrees Celsius." + ::= { airIRG3CMThresholdsEntry 4 } + + +airIRG3CMThresholdsSupplyAirTempHighUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The CM high threshold for supply air temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3CMThresholdsEntry 5 } + + +airIRG3CMThresholdsSupplyAirTempHighMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The CM high threshold for supply air temperature in tenths of + degrees Celsius." + ::= { airIRG3CMThresholdsEntry 6 } + + +airIRG3CMThresholdsReturnAirTempHighUS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The CM high threshold for return air temperature in tenths of + degrees Fahrenheit." + ::= { airIRG3CMThresholdsEntry 7 } + + +airIRG3CMThresholdsReturnAirTempHighMetric OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The CM high threshold for return air temperature in tenths of + degrees Celsius." + ::= { airIRG3CMThresholdsEntry 8 } + + +-- *************************************** +-- airIRG3 CM Setpoints +-- *************************************** + +AirIRG3CMSetpointsEntry ::= SEQUENCE { + airIRG3CMSetpointsDeviceIndex INTEGER + } + +airIRG3CMSetpointsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3CMSetpointsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to access CM set points table." + ::= { airIRG3CM 6 } + +airIRG3CMSetpointsEntry OBJECT-TYPE + SYNTAX AirIRG3CMSetpointsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The CM set points table entry." + INDEX { airIRG3CMSetpointsDeviceIndex} + ::= { airIRG3CMSetpointsTable 1 } + +airIRG3CMSetpointsDeviceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of CM set points table." + ::= { airIRG3CMSetpointsEntry 1 } + + + +-- *************************************** +-- airIRG3 CM Config +-- *************************************** + +AirIRG3CMConfigEntry ::= SEQUENCE { + airIRG3CMConfigDeviceIndex INTEGER, + airIRG3CMConfigCMID DisplayString, + airIRG3CMConfigStopOnCoolFail INTEGER, + airIRG3CMConfigStartupDelay INTEGER, + airIRG3CMConfigRemoteOnStandby INTEGER, + airIRG3CMConfigPowerSource INTEGER + } + +airIRG3CMConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirIRG3CMConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows to access CM configuration table." + ::= { airIRG3CM 7 } + +airIRG3CMConfigEntry OBJECT-TYPE + SYNTAX AirIRG3CMConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The CM configuration table entry." + INDEX { airIRG3CMConfigDeviceIndex} + ::= { airIRG3CMConfigTable 1 } + +airIRG3CMConfigDeviceIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Index of CM configuration table." + ::= { airIRG3CMConfigEntry 1 } + +airIRG3CMConfigCMID OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The CM ID (RDU Number - Group Number - CM Unit Number)." + ::= { airIRG3CMConfigEntry 2 } + +airIRG3CMConfigStopOnCoolFail OBJECT-TYPE + SYNTAX INTEGER{ + no (1), + yes (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/Disable Stop On cool fail. When enabled, stops the unit + if it detects that it is blowing warm air into the cold aisle." + ::= { airIRG3CMConfigEntry 3 } + + +airIRG3CMConfigStartupDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The CM start up delay in seconds." + ::= { airIRG3CMConfigEntry 4 } + + +airIRG3CMConfigRemoteOnStandby OBJECT-TYPE + SYNTAX INTEGER{ + standBy (1), + on (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The CM configuration for operating mode." + ::= { airIRG3CMConfigEntry 5 } + + +airIRG3CMConfigPowerSource OBJECT-TYPE + SYNTAX INTEGER{ + singleFeed (1), + dualFeed (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The CM power source." + ::= { airIRG3CMConfigEntry 6 } + + +-- End of airIRGen3 + + +-- RACK AIR REMOVAL UNIT IDENT + +rARUIdentTable OBJECT-TYPE + SYNTAX SEQUENCE OF RARUIdentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for query of the individual devices. + The number of entries is contained in the + rARUStatusAruDeviceCount OID." + ::= { rARUIdent 1 } + +rARUIdentEntry OBJECT-TYPE + SYNTAX RARUIdentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The device to query." + INDEX { rARUIdentAruIndex} + ::= { rARUIdentTable 1 } + +RARUIdentEntry ::= + SEQUENCE { + rARUIdentAruIndex INTEGER, + rARUIdentName DisplayString + } + +rARUIdentAruIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the ARU entry." + ::= { rARUIdentEntry 1 } + +rARUIdentName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the device. " + ::= { rARUIdentEntry 2 } + +-- RACK AIR REMOVAL UNIT CONFIGURATION + +rARUConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF RARUConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for configuration of the individual ARU devices accessible from this IP address. + The number of entries is contained in the rARUStatusAruDeviceCount OID." + ::= { rARUConfig 1 } + +rARUConfigEntry OBJECT-TYPE + SYNTAX RARUConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The ARUs to configure." + INDEX { rARUConfigAruIndex } + ::= { rARUConfigTable 1 } + +RARUConfigEntry ::= + SEQUENCE { + rARUConfigAruIndex INTEGER, + rARUConfigAruName DisplayString, + rARUConfigAruRemoteSetpoint INTEGER, + rARUConfigAruTempOvrdEnableDisable INTEGER, + rARUConfigAruTempOvrdSetpoint INTEGER, + rARUConfigAruMasterControl INTEGER + } + +rARUConfigAruIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the ARU entry." + ::= { rARUConfigEntry 1 } + +rARUConfigAruName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the ARU." + ::= { rARUConfigEntry 2 } + +rARUConfigAruRemoteSetpoint OBJECT-TYPE + SYNTAX INTEGER { + aruOff (1), + aru85F-29C (2), + aru90F-32C (3), + aru95F-35C (4), + aru100F-38C (5), + aru7kW-1200cfm (6), + aru5kW-800cfm (7), + aru3kW-500cfm (8), + aru2kW-300cfm (9), + aru400cfm (10), + aru600cfm (11), + aru700cfm (12), + aru900cfm (13), + aru1000cfm (14), + aru1400cfm (15), + aru1600cfm (16), + aru1800cfm (17), + aru2000cfm (18) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This OID defines the desired base airflow of the ARU, and sets the + speed of the ARU fans when the temperature override is inactive. + + Values specified in cfm (cubic feet per minute) can be converted + to metric values using the conversion factor: + + 1 cfm = 1.70 m^3/hr (cubic meters per hour). + + Values (1) through (9) are for support of legacy (1st generation) ARUs. + Writing these values to a 2nd generation ARU will result in the following: + A value greater than (9) will be ignored by a 1st generation ARU. + + aruOff (1) - Ignored + aru85F-29C (2) - 1200 cfm + aru90F-32C (3) - 800 cfm + aru95F-35C (4) - 500 cfm + aru100F-38C (5) - 400 cfm + aru7kW (6) - 1200 cfm + aru5kW (7) - 800 cfm + aru3kW (8) - 500 cfm + aru2kW (9) - 400 cfm + + NOTE: -1 will be returned if the ARU is not communicating." + ::= { rARUConfigEntry 3 } + +rARUConfigAruTempOvrdEnableDisable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This OID is used to enable/disable the remote temperature override setting of the ARU. + + If this OID is set to 1, the remote setting for temperature override is disabled. + If this OID is set to 2, the remote setting for temperature override is enabled." + ::= { rARUConfigEntry 4 } + +rARUConfigAruTempOvrdSetpoint OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This OID is the Temperature Override setpoint of the ARU. + + NOTE: -1 will be returned if the ARU is not communicating. + + Values are represented in whole number degrees using the + units specified in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { rARUConfigEntry 5 } + +rARUConfigAruMasterControl OBJECT-TYPE + SYNTAX INTEGER { + aruOn (1), + aruOff (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This is the master on/off control for the ARU." + ::= { rARUConfigEntry 6 } + +-- RACK AIR REMOVAL UNIT STATUS + +rARUStatusAruDeviceCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of ARUs accessible from this IP." + ::= { rARUStatus 1 } + +rARUStatusSysTempUnits OBJECT-TYPE + SYNTAX INTEGER { + celsius(1), + fahrenheit(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature scale used to display the temperature + in the system, Celsius(1) or Fahrenheit(2). + This setting is based on the system preferences + configuration in the agent." + ::= { rARUStatus 2 } + +rARUStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RARUStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for query of the individual ARUs accessible from this IP address. + The number of entries is contained in the rARUStatusAruDeviceCount OID." + ::= { rARUStatus 3 } + +rARUStatusEntry OBJECT-TYPE + SYNTAX RARUStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The ARUs to access." + INDEX { rARUStatusAruIndex } + ::= { rARUStatusTable 1 } + +RARUStatusEntry ::= + SEQUENCE { + rARUStatusAruIndex INTEGER, + rARUStatusAruName DisplayString, + rARUStatusAruRemoteSetpoint INTEGER, + rARUStatusAruManualSetpoint INTEGER, + rARUStatusAruTemp1 INTEGER, + rARUStatusAruTemp2 INTEGER, + rARUStatusAruTemp3 INTEGER, + rARUStatusAruTempOvrdEnableDisable INTEGER, + rARUStatusAruTempOvrdSetpoint INTEGER, + rARUStatusAruAlarmState DisplayString, + rARUStatusAruCommStatus INTEGER, + rARUStatusAruTempOvrdStatus INTEGER, + rARUStatusAruMasterControl INTEGER, + rARUStatusAruTotalAirflow INTEGER + } + +rARUStatusAruIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the ARU entry." + ::= { rARUStatusEntry 1 } + +rARUStatusAruName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the ARU." + ::= { rARUStatusEntry 2 } + +rARUStatusAruRemoteSetpoint OBJECT-TYPE + SYNTAX INTEGER { + aruOff (1), + aru85F-29C (2), + aru90F-32C (3), + aru95F-35C (4), + aru100F-38C (5), + aru7kW-1200cfm (6), + aru5kW-800cfm (7), + aru3kW-500cfm (8), + aru2kW-300cfm (9), + aru400cfm (10), + aru600cfm (11), + aru700cfm (12), + aru900cfm (13), + aru1000cfm (14), + aru1400cfm (15), + aru1600cfm (16), + aru1800cfm (17), + aru2000cfm (18) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID defines the desired base airflow of the ARU, or the + speed of the ARU fans when the temperature override is inactive. + + See also the rARUConfigAruRemoteSetpoint OID. + + NOTE: -1 will be returned if the ARU is not communicating." + ::= { rARUStatusEntry 3 } + +rARUStatusAruManualSetpoint OBJECT-TYPE + SYNTAX INTEGER { + aruOff (1), + aru85F-29C (2), + aru90F-32C (3), + aru95F-35C (4), + aru100F-38C (5), + aru7kW (6), + aru5kW (7), + aru3kW (8), + aru2kW (9), + aruRem (10) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Manual operating setpoint of the ARU, which is set on the + panel of the ARU. If the ARU doesn't have a manual , + the OID will always return a value of aruRem (10). + + NOTE: -1 will be returned if the ARU is not communicating. + + Values are represented in whole number degrees or kW. + If the manual setpoint is set to Remote, or if the ARU doesn't + have a manual switch, this OID will return aruRem." + ::= { rARUStatusEntry 4 } + +rARUStatusAruTemp1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "ARU temperature probe #1 reading. + The summary exhaust temperature on 2nd generation ARUs. + + NOTE: -1 will be returned if the ARU is not communicating. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { rARUStatusEntry 5 } + +rARUStatusAruTemp2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "ARU temperature probe #2 reading. + The exhaust temperature in the upper plenum on 2nd generation ARUs. + + NOTE: -1 will be returned if the ARU is not communicating. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { rARUStatusEntry 6 } + +rARUStatusAruTemp3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "ARU temperature probe #3 reading. + The exhaust temperature in the lower plenum on 2nd generation ARUs. + + NOTE: -1 will be returned if the ARU is not communicating. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { rARUStatusEntry 7 } + +rARUStatusAruTempOvrdEnableDisable OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This OID indicates whether the ARU remote temperature override is enabled or disabled. + If this OID is a 1, the remote setting for temperature override is disabled. + If this OID is a 2, the remote setting for temperature override is enabled." + ::= { rARUStatusEntry 8 } + +rARUStatusAruTempOvrdSetpoint OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "ARU remote temperature override setpoint setting. + + NOTE: -1 will be returned if the ARU is not communicating. + + Values are represented in whole number degrees. + Units are displayed in the scale shown in + the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)." + ::= { rARUStatusEntry 9 } + +rARUStatusAruAlarmState OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ASCII string containing the 8 flags representing + the current alarm state of the ARU. If the state of + the ARU is unknown, this variable is set to 'UNKNOWN'. + + The flags are numbered 1 to 8, read from left to + right. The flags are defined as follows: + + Flag 1: Fan Fail 1 + Flag 2: Fan Fail 2 + Flag 3: Fan Fail 3 + Flag 4: Smoke (if ARU is equipped with smoke detector) + + Flag 5: High Temp (Out of Thermal Control) + Flag 6: Over Temp (Exhaust Temp. Exceeds Override Setpoint) + Flag 7: Fan Fail 4 (Gen 2 ARU only) + Flag 8: Reserved" + ::= { rARUStatusEntry 10 } + +rARUStatusAruCommStatus OBJECT-TYPE + SYNTAX INTEGER { + commsNeverDiscovered(1), + commsEstablished(2), + commsLost(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of communications to the device. + commNeverDiscovered(1) indicates there has never been communications with this device. + commsEstablished(2) indicates communication is normal and active with this device. + commsLost(3) indicates communication had been established, but is no device." + ::= { rARUStatusEntry 11 } + +rARUStatusAruTempOvrdStatus OBJECT-TYPE + SYNTAX INTEGER { + inactive (1), + active (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Specifies whether the ARU is increasing airflow because + exhaust air temperature has exceeded the setting specified in the + rARUConfigAruTempOvrdSetpoint OID." + ::= { rARUStatusEntry 12 } + +rARUStatusAruMasterControl OBJECT-TYPE + SYNTAX INTEGER { + aruOn (1), + aruOff (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This is the master on/off control for the ARU." + ::= { rARUStatusEntry 13 } + +rARUStatusAruTotalAirflow OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total airflow provided by the aru. Specified in cfm (cubic feet per minute). + Can be converted to metric values using the conversion factor: + 1 cfm = 1.70 m^3/hr (cubic meters per hour)." + ::= { rARUStatusEntry 14 } + +-- RACK AIR REMOVAL UNIT FAN STATUS + +rARUFanStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RARUFanStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for query of the individual devices. + The number of entries is contained in the + rARUStatusAruDeviceCount OID." + ::= { rARUFanStatus 1 } + +rARUFanStatusEntry OBJECT-TYPE + SYNTAX RARUFanStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The device to query." + INDEX { rARUFanStatusAruIndex, rARUFanStatusFanIndex} + ::= { rARUFanStatusTable 1 } + +RARUFanStatusEntry ::= + SEQUENCE { + rARUFanStatusAruIndex INTEGER, + rARUFanStatusNominalFanSpeed INTEGER, + rARUFanStatusSelectedFanLevel INTEGER, + rARUFanStatusReplacementThreshold INTEGER, + rARUFanStatusFanIndex INTEGER, + rARUFanStatusFanOperatingStatus INTEGER, + rARUFanStatusFanRpmSpeed INTEGER, + rARUFanStatusFanFlowRate INTEGER, + rARUFanStatusFanInServiceDate DisplayString, + rARUFanStatusFanRunhourCounter INTEGER, + rARUFanStatusFanRunhourReset INTEGER + } + +rARUFanStatusAruIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the ARU entry." + ::= { rARUFanStatusEntry 1 } + +rARUFanStatusNominalFanSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal rotational speed (RPM) of the fans when they are + operating at the 100% level." + ::= { rARUFanStatusEntry 2 } + +rARUFanStatusSelectedFanLevel OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The currently selected ARU speed level, + specified in percent of full capacity." + ::= { rARUFanStatusEntry 3 } + +rARUFanStatusReplacementThreshold OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + khr20 (2), + khr25 (3), + khr30 (4), + khr35 (5), + khr40 (6), + khr50 (7) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Threshold above which a run hour alarm will exist, indicating + that it might be time to proactively replace a fan." + ::= { rARUFanStatusEntry 4 } + +rARUFanStatusFanIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to an individual fan table entry." + ::= { rARUFanStatusEntry 5 } + +rARUFanStatusFanOperatingStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown (1), + off (2), + onOk (3), + onDegraded (4), + offFailed (5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current operating state of the fan." + ::= { rARUFanStatusEntry 6 } + +rARUFanStatusFanRpmSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current rotational speed of the fan, + specified in rotations per minute (RPM)." + ::= { rARUFanStatusEntry 7 } + +rARUFanStatusFanFlowRate OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The flow rate provided by the fan, based on its measured rotational speed. + Specified in cfm (cubic feet per minute). Can be converted to metric values + using the conversion factor: 1 cfm = 1.70 m^3/hr (cubic meters per hour)." + ::= { rARUFanStatusEntry 8 } + +rARUFanStatusFanInServiceDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The installation/replacement date of the fan." + ::= { rARUFanStatusEntry 9 } + +rARUFanStatusFanRunhourCounter OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total time for which the fan has been running. + Specified in 10ths of hours." + ::= { rARUFanStatusEntry 10 } + +rARUFanStatusFanRunhourReset OBJECT-TYPE + SYNTAX INTEGER { + yes (1), + no (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Writing yes to this This OID will reset a fan's total run hour counter, + which is shown in the rARUFanStatusFanRunhourCounter OID." + ::= { rARUFanStatusEntry 11 } + +-- RACK AIR REMOVAL UNIT INPUT POWER STATUS + +rARUPowerStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RARUPowerStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for query of the individual ARUs accessible from this IP address. + The number of entries is contained in the rARUStatusAruDeviceCount OID." + ::= { rARUPower 1 } + +rARUPowerStatusEntry OBJECT-TYPE + SYNTAX RARUPowerStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The device to query." + INDEX { rARUPowerStatusAruIndex} + ::= { rARUPowerStatusTable 1 } + +RARUPowerStatusEntry ::= + SEQUENCE { + rARUPowerStatusAruIndex INTEGER, + rARUPowerStatusPrimaryAcPresent INTEGER, + rARUPowerStatusAuxiliaryAcPresent INTEGER, + rARUPowerStatusRedundantAcConfig INTEGER + } + +rARUPowerStatusAruIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the ARU entry." + ::= { rARUPowerStatusEntry 1 } + +rARUPowerStatusPrimaryAcPresent OBJECT-TYPE + SYNTAX INTEGER { + yes (1), + no (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not line voltage is present on AC input 1." + ::= { rARUPowerStatusEntry 2 } + +rARUPowerStatusAuxiliaryAcPresent OBJECT-TYPE + SYNTAX INTEGER { + yes (1), + no (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not line voltage is present on AC input 2." + ::= { rARUPowerStatusEntry 3 } + +rARUPowerStatusRedundantAcConfig OBJECT-TYPE + SYNTAX INTEGER { + singleCord (1), + dualCord (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Indicates whether or not a dual cord is in use. + When this setting is set to dualCord (2), aruRedundantPowerLostAlarm + traps will be generated when either primary or auxiliary input + voltage is not present. When this setting is set to singleCord (1), + aruRedundantPowerLostAlarm traps will not be generated." + ::= { rARUPowerStatusEntry 4 } + +-- RACK AIR REMOVAL UNIT SENSOR STATUS + +rARUSensorsStatusTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the rARUSensorsStatusTable." + ::= { rARUSensors 1 } + +rARUSensorsStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RARUSensorsStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting environmental sensor status information." + ::= { rARUSensors 2 } + +rARUSensorsStatusEntry OBJECT-TYPE + SYNTAX RARUSensorsStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { rARUSensorsStatusAruIndex, rARUSensorsStatusSensorNumber } + ::= { rARUSensorsStatusTable 1 } + +RARUSensorsStatusEntry ::= + SEQUENCE { + rARUSensorsStatusAruIndex INTEGER, + rARUSensorsStatusSensorNumber INTEGER, + rARUSensorsTemperature INTEGER + } + +rARUSensorsStatusAruIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the ARU entry." + ::= { rARUSensorsStatusEntry 1 } + +rARUSensorsStatusSensorNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of the sensor on the device." + ::= { rARUSensorsStatusEntry 2 } + +rARUSensorsTemperature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The sensor's current temperature reading. The temperature scale + is based on the system preferences configuration." + ::= { rARUSensorsStatusEntry 3 } + + +-- RACK AIR REMOVAL UNIT CONFIG STATUS + +rARUSensorsConfigTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the rARUSensorsConfigTable." + ::= { rARUSensors 3 } + +rARUSensorsConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF RARUSensorsConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting configuration information from + environmental sensors attached to the device." + ::= { rARUSensors 4 } + +rARUSensorsConfigEntry OBJECT-TYPE + SYNTAX RARUSensorsConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit to get data from." + INDEX { rARUSensorsConfigAruIndex, rARUSensorsConfigSensorNumber } + ::= { rARUSensorsConfigTable 1 } + +RARUSensorsConfigEntry ::= + SEQUENCE { + rARUSensorsConfigAruIndex INTEGER, + rARUSensorsConfigSensorNumber INTEGER, + rARUSensorsName DisplayString, + rARUSensorsLocation DisplayString, + rARUSensorsTempMaxThresh INTEGER, + rARUSensorsTempHighThresh INTEGER, + rARUSensorsTempLowThresh INTEGER, + rARUSensorsTempMinThresh INTEGER, + rARUSensorsTempThreshHysteresis INTEGER, + rARUSensorsTempShortDecRateThreshValue INTEGER, + rARUSensorsTempShortDecRateThreshTime INTEGER, + rARUSensorsTempShortIncRateThreshValue INTEGER, + rARUSensorsTempShortIncRateThreshTime INTEGER, + rARUSensorsTempLongDecRateThreshValue INTEGER, + rARUSensorsTempLongDecRateThreshTime INTEGER, + rARUSensorsTempLongIncRateThreshValue INTEGER, + rARUSensorsTempLongIncRateThreshTime INTEGER + } + +rARUSensorsConfigAruIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to the ARU entry." + ::= { rARUSensorsConfigEntry 1 } + +rARUSensorsConfigSensorNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of the sensor on the device." + ::= { rARUSensorsConfigEntry 2 } + +rARUSensorsName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A descriptive name for the sensor." + ::= { rARUSensorsConfigEntry 3 } + +rARUSensorsLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The location of the sensor." + ::= { rARUSensorsConfigEntry 4 } + +rARUSensorsTempMaxThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The temperature at which a maximum temperature threshold + violation alarm will be generated for this sensor. + The temperature scale is based on the system preferences + configuration." + ::= { rARUSensorsConfigEntry 5 } + +rARUSensorsTempHighThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The temperature at which a high temperature threshold + violation alarm will be generated for this sensor. + The temperature scale is based on the system preferences + configuration." + ::= { rARUSensorsConfigEntry 6 } + +rARUSensorsTempLowThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The temperature at which a low temperature threshold + violation alarm will be generated for this sensor. + The temperature scale is based on the system preferences + configuration." + ::= { rARUSensorsConfigEntry 7 } + +rARUSensorsTempMinThresh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The temperature at which a min temperature threshold + violation alarm will be generated for this sensor. + The temperature scale is based on the system preferences + configuration." + ::= { rARUSensorsConfigEntry 8 } + +rARUSensorsTempThreshHysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The change in temperature required to cause a + temperature alarm to change from an active to an + inactive state. The temperature scale is based on + the system preferences configuration." + ::= { rARUSensorsConfigEntry 9 } + +rARUSensorsTempShortDecRateThreshValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of the temperature short-term decreasing rate + time that will cause an alarm to be generated. + The temperature scale is based on the system preferences + configuration." + ::= { rARUSensorsConfigEntry 10 } + +rARUSensorsTempShortDecRateThreshTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The time over which the temperature may not decrease + beyond the value specified by the temperature short-term + decreasing rate threshold value." + ::= { rARUSensorsConfigEntry 11 } + +rARUSensorsTempShortIncRateThreshValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of the temperature short-term increasing rate + time that will cause an alarm to be generated. + The temperature scale is based on the system preferences + configuration." + ::= { rARUSensorsConfigEntry 12 } + +rARUSensorsTempShortIncRateThreshTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The time over which the temperature may not increase + beyond the value specified by the temperature short-term + increasing rate threshold value." + ::= { rARUSensorsConfigEntry 13 } + +rARUSensorsTempLongDecRateThreshValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of the temperature long-term decreasing rate + time that will cause an alarm to be generated. + The temperature scale is based on the system preferences + configuration." + ::= { rARUSensorsConfigEntry 14 } + +rARUSensorsTempLongDecRateThreshTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The time over which the temperature may not decrease + beyond the value specified by the temperature long-term + decreasing rate threshold value." + ::= { rARUSensorsConfigEntry 15 } + +rARUSensorsTempLongIncRateThreshValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of the temperature long-term increasing rate + time that will cause an alarm to be generated. + The temperature scale is based on the system preferences + configuration." + ::= { rARUSensorsConfigEntry 16 } + +rARUSensorsTempLongIncRateThreshTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The time over which the temperature may not increase + beyond the value specified by the temperature long-term + increasing rate threshold value." + ::= { rARUSensorsConfigEntry 17 } + +-- MODULAR DISTRIBUTION SYSTEM + +-- Modular Information + +isxModularDistInfoTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the isxModularDistInfoTable." + ::= { isxModularDistInfo 1 } + +isxModularDistInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF IsxModularDistInfoEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information about the modular + distribution metering equipment." + ::= { isxModularDistInfo 2 } + +isxModularDistInfoEntry OBJECT-TYPE + SYNTAX IsxModularDistInfoEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information about an individual metering segment." + INDEX { isxModularDistInfoSegmentIndex } + ::= { isxModularDistInfoTable 1 } + +IsxModularDistInfoEntry ::= + SEQUENCE { + isxModularDistInfoSegmentIndex INTEGER, + isxModularDistInfoMeterModelNumber DisplayString, + isxModularDistInfoMeterSerialNumber DisplayString, + isxModularDistInfoMeterDateOfManufacture DisplayString, + isxModularDistInfoMeterFirmwareRev DisplayString, + isxModularDistInfoMeterHardwareRev DisplayString + } + +isxModularDistInfoSegmentIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the metering segment." + ::= { isxModularDistInfoEntry 1 } + +isxModularDistInfoMeterModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The model number of the metering board for this segment." + ::= { isxModularDistInfoEntry 2 } + +isxModularDistInfoMeterSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the metering board for this segment." + ::= { isxModularDistInfoEntry 3 } + +isxModularDistInfoMeterDateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date of manufacture for the metering board for this segment, + in the format mm/dd/yyyy." + ::= { isxModularDistInfoEntry 4 } + +isxModularDistInfoMeterFirmwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware revision number of the metering board for this segment." + ::= { isxModularDistInfoEntry 5 } + +isxModularDistInfoMeterHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision number of the metering board for this segment." + ::= { isxModularDistInfoEntry 6 } + +-- Distribution Modules + +isxModularDistModuleInfoTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the isxModularDistModuleInfoTable." + ::= { isxModularDistModules 1 } + +isxModularDistModuleInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF IsxModularDistModuleInfoEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting basic information about the distribution modules + installed in the system." + ::= { isxModularDistModules 2 } + +isxModularDistModuleInfoEntry OBJECT-TYPE + SYNTAX IsxModularDistModuleInfoEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information about a specific distribution module." + INDEX { isxModularDistModuleInfoModIndex } + ::= { isxModularDistModuleInfoTable 1 } + +IsxModularDistModuleInfoEntry ::= + SEQUENCE { + isxModularDistModuleInfoModIndex INTEGER, + isxModularDistModuleInfoAlarmStatus INTEGER, + isxModularDistModuleInfoModelNumber DisplayString, + isxModularDistModuleInfoSerialNumber DisplayString, + isxModularDistModuleInfoDateOfManufacture DisplayString, + isxModularDistModuleInfoNumCables INTEGER + } + +isxModularDistModuleInfoModIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of the distribution module." + ::= { isxModularDistModuleInfoEntry 1 } + +isxModularDistModuleInfoAlarmStatus OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + warning (2), + critical (3), + notPresent (4), + unknown (5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of this module. This reflects the indicator lamp(s) on the front of the module. + A value of notPresent indicates that the module is not installed. + A value of unknown indicates that there is no communication with the + metering segment for this module." + ::= { isxModularDistModuleInfoEntry 2 } + +isxModularDistModuleInfoModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The model number of the distribution module." + ::= { isxModularDistModuleInfoEntry 3 } + +isxModularDistModuleInfoSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The serial number of the distribution module." + ::= { isxModularDistModuleInfoEntry 4 } + +isxModularDistModuleInfoDateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date that the distribution module was manufactured." + ::= { isxModularDistModuleInfoEntry 5 } + +isxModularDistModuleInfoNumCables OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of cables provided by this distribution module." + ::= { isxModularDistModuleInfoEntry 6 } + +isxModularDistModuleBreakerTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the isxModularDistModuleBreakerTable." + ::= { isxModularDistModules 3 } + +isxModularDistModuleBreakerTable OBJECT-TYPE + SYNTAX SEQUENCE OF IsxModularDistModuleBreakerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting operational information about the distribution modules." + ::= { isxModularDistModules 4 } + +isxModularDistModuleBreakerEntry OBJECT-TYPE + SYNTAX IsxModularDistModuleBreakerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information about a specific distribution modules and circuit breakers." + INDEX { isxModularDistModuleBreakerModIndex, isxModularDistModuleBreakerPhaseIndex} + ::= { isxModularDistModuleBreakerTable 1 } + +IsxModularDistModuleBreakerEntry ::= + SEQUENCE { + isxModularDistModuleBreakerModIndex INTEGER, + isxModularDistModuleBreakerPhaseIndex INTEGER, + isxModularDistModuleBreakerAlarmStatus INTEGER, + isxModularDistModuleBreakerRating INTEGER, + isxModularDistModuleBreakerPhysicalGroup INTEGER, + isxModularDistModuleBreakerCableNum INTEGER, + isxModularDistModuleBreakerPosition INTEGER, + isxModularDistModuleBreakerPositionAlarms INTEGER, + isxModularDistModuleBreakerCurrent INTEGER, + isxModularDistModuleBreakerPercent INTEGER, + isxModularDistModuleBreakerPower INTEGER + } + +isxModularDistModuleBreakerModIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The distribution module number." + ::= { isxModularDistModuleBreakerEntry 1 } + +isxModularDistModuleBreakerPhaseIndex OBJECT-TYPE + SYNTAX INTEGER{ + phaseL1(1), + phaseL2(2), + phaseL3(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to an individual breaker in the distribution module. The index also corresponds + to the system phase to which the breaker is attached." + ::= { isxModularDistModuleBreakerEntry 2 } + +isxModularDistModuleBreakerAlarmStatus OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This is a bit map representing the active alarms for this breaker: + + b0 - Minimum current threshold exceeded (critical) + b1 - Low current threshold exceeded (warning) + b2 - High current threshold exceeded (warning) + b3 - Maximum current threshold exceeded (critical) + b4 - Breaker is open (critical) + + If a bit is set, the corresponding alarm is active." + ::= { isxModularDistModuleBreakerEntry 3 } + +isxModularDistModuleBreakerRating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current rating of the breaker." + ::= { isxModularDistModuleBreakerEntry 4 } + +isxModularDistModuleBreakerPhysicalGroup OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Numeric value used to indicate that a breaker is a part of a multi-pole breaker. + Breakers within a distribution module, with equivalent physical group numbers, + may have their handles physically tied together. + A value of 1 indicates breakers that are physically tied together as part of a + multi-pole breaker. + A value of 0 indicates a single-handle breaker that is not physically tied to + another breaker." + ::= { isxModularDistModuleBreakerEntry 5 } + +isxModularDistModuleBreakerCableNum OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Numeric value used to indicate the distribution cable to which + this breaker is connected. These distribution cables are described + in the table isxModularDistModuleOutputTable, + and indexed by the OID isxModularDistModuleOutputCordIndex." + ::= { isxModularDistModuleBreakerEntry 6 } + +isxModularDistModuleBreakerPosition OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The physical status of this breaker pole, either closed or open (including tripped)." + ::= { isxModularDistModuleBreakerEntry 7 } + +isxModularDistModuleBreakerPositionAlarms OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable breaker position alarms for this circuit breaker." + ::= { isxModularDistModuleBreakerEntry 8 } + +isxModularDistModuleBreakerCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current flowing though this breaker. Measured in tenths of amps." + ::= { isxModularDistModuleBreakerEntry 9 } + +isxModularDistModuleBreakerPercent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The loading on this breaker as a percentage of the breaker's current rating. + Expressed in tenths of percent." + ::= { isxModularDistModuleBreakerEntry 10 } + +isxModularDistModuleBreakerPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The power being supplied through this breaker. Measured in tenths of kW." + ::= { isxModularDistModuleBreakerEntry 11 } + +isxModularDistModuleOutputsTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the isxModularDistModuleOutputTable." + ::= { isxModularDistModules 5 } + +isxModularDistModuleOutputTable OBJECT-TYPE + SYNTAX SEQUENCE OF IsxModularDistModuleOutputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting and setting information related to the + load equipment being fed by the distribution modules in the ISX + Modular Distribution System." + ::= { isxModularDistModules 6 } + +isxModularDistModuleOutputEntry OBJECT-TYPE + SYNTAX IsxModularDistModuleOutputEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information about a specific distribution module + and its output distribution cables." + INDEX { isxModularDistModuleOutputModIndex, isxModularDistModuleOutputCordIndex } + ::= { isxModularDistModuleOutputTable 1 } + +IsxModularDistModuleOutputEntry ::= + SEQUENCE { + isxModularDistModuleOutputModIndex INTEGER, + isxModularDistModuleOutputNumCables INTEGER, + isxModularDistModuleOutputCordIndex INTEGER, + isxModularDistModuleOutputName DisplayString, + isxModularDistModuleOutputLocation DisplayString, + isxModularDistModuleOutputStatus INTEGER, + isxModularDistModuleOutputAlarmGeneration INTEGER, + isxModularDistModuleOutputBreakerMap INTEGER, + isxModularDistModuleOutputThresholdMin INTEGER, + isxModularDistModuleOutputThresholdLow INTEGER, + isxModularDistModuleOutputThresholdHigh INTEGER, + isxModularDistModuleOutputThresholdMax INTEGER, + isxModularDistModuleOutputAlarmMinEnable INTEGER, + isxModularDistModuleOutputAlarmLowEnable INTEGER, + isxModularDistModuleOutputAlarmHighEnable INTEGER, + isxModularDistModuleOutputAlarmMaxEnable INTEGER, + isxModularDistModuleOutputCableLength INTEGER, + isxModularDistModuleOutputConnectorType DisplayString, + isxModularDistModuleOutputAvailableVoltages INTEGER, + isxModularDistModuleOutputTotalPower INTEGER, + isxModularDistModuleOutputKwhUsage INTEGER, + isxModularDistModuleOutputKwhReset INTEGER, + isxModularDistModuleOutputKwhResetDate DisplayString + } + +isxModularDistModuleOutputModIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of the distribution module supplying power to the load equipment." + ::= { isxModularDistModuleOutputEntry 1 } + +isxModularDistModuleOutputNumCables OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of distribution cables provided by this module." + ::= { isxModularDistModuleOutputEntry 2 } + +isxModularDistModuleOutputCordIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of an individual distribution cable supplied by this module." + ::= { isxModularDistModuleOutputEntry 3 } + +isxModularDistModuleOutputName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A string describing the load equipment being supplied by this distribution cable." + ::= { isxModularDistModuleOutputEntry 4 } + +isxModularDistModuleOutputLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A string describing the location of equipment being supplied by distribution cable." + ::= { isxModularDistModuleOutputEntry 5 } + +isxModularDistModuleOutputStatus OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + warning (2), + critical (3), + notPresent (4), + unknown (6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This reflects the worse case severity for alarms associated with this distribution cable. + A value of notPresent indicates that the cable does not exist for this module. + A value of unknown indicates that the there is no communication with the + metering segment for this distribution cable's module." + ::= { isxModularDistModuleOutputEntry 6 } + +isxModularDistModuleOutputAlarmGeneration OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable all alarm generation related to this distribution cable." + ::= { isxModularDistModuleOutputEntry 7 } + +isxModularDistModuleOutputBreakerMap OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This is a bit map representing the breaker poles within the + module that are associated with this distribution cable. + The following 3 bits are used to indicate the indices of + the breakers feeding the cable: + + b0 - Module breaker L1 + b1 - Module breaker L2 + b2 - Module breaker L3 + + If a bit is set, the breaker is used to feed this distribution cable. + These breakers are described in the table isxModularDistModuleBreakerTable, + and indexed by the OID isxModularDistModuleBreakerPhaseIndex." + ::= { isxModularDistModuleOutputEntry 8 } + +isxModularDistModuleOutputThresholdMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When the current drops below this value a critical alarm will exist." + ::= { isxModularDistModuleOutputEntry 9 } + +isxModularDistModuleOutputThresholdLow OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When the current drops below this value a warning alarm will exist." + ::= { isxModularDistModuleOutputEntry 10 } + +isxModularDistModuleOutputThresholdHigh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When the current exceeds this value a warning alarm will exist." + ::= { isxModularDistModuleOutputEntry 11 } + +isxModularDistModuleOutputThresholdMax OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When the current exceeds this value a critical alarm will exist." + ::= { isxModularDistModuleOutputEntry 12 } + +isxModularDistModuleOutputAlarmMinEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable minimum current alarm generation for this distribution cable." + ::= { isxModularDistModuleOutputEntry 13 } + +isxModularDistModuleOutputAlarmLowEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable low current alarm generation for this distribution cable." + ::= { isxModularDistModuleOutputEntry 14 } + +isxModularDistModuleOutputAlarmHighEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable high current alarm generation for this distribution cable." + ::= { isxModularDistModuleOutputEntry 15 } + +isxModularDistModuleOutputAlarmMaxEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable maximum current alarm generation for this distribution cable." + ::= { isxModularDistModuleOutputEntry 16 } + +isxModularDistModuleOutputCableLength OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The length of this distribution cable. Specified in tenths of meters." + ::= { isxModularDistModuleOutputEntry 17 } + +isxModularDistModuleOutputConnectorType OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A string describing the connector on the end of this distribution cable." + ::= { isxModularDistModuleOutputEntry 18 } + +isxModularDistModuleOutputAvailableVoltages OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This is a bit map representing the voltages that are available at the connector. + 6 bits are used to indicate the following: + + b0 - L1 + b1 - L2 + b2 - L3 + b3 - L1-2 + b4 - L2-3 + b5 - L3-1" + ::= { isxModularDistModuleOutputEntry 19 } + +isxModularDistModuleOutputTotalPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total power being consumed by the load equipment supplied by this distribution cable. + Measured in tenths of kW." + ::= { isxModularDistModuleOutputEntry 20 } + +isxModularDistModuleOutputKwhUsage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total energy consumed by the load equipment fed by this distribution cable. + This is the total since the date specified in the isxModularDistModuleOutputKwhResetDate + OID, and may be cleared using the isxModularDistModuleOutputKwhReset OID. + Measured in tenths of kWh." + ::= { isxModularDistModuleOutputEntry 21 } + +isxModularDistModuleOutputKwhReset OBJECT-TYPE + SYNTAX INTEGER { + no (1), + yes (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Writing yes to this OID will reset the total kWh usage shown + in the isxModularDistModuleOutputKwhUsage OID." + ::= { isxModularDistModuleOutputEntry 22 } + +isxModularDistModuleOutputKwhResetDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000." + ::= { isxModularDistModuleOutputEntry 23 } + +-- Distribution Subfeeds + +isxModularDistSubFeedInfoTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the isxModularDistSubFeedInfoTable." + ::= { isxModularDistSubFeeds 1 } + +isxModularDistSubFeedInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF IsxModularDistSubFeedInfoEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting information about distribution subfeed breakers." + ::= { isxModularDistSubFeeds 2 } + +isxModularDistSubFeedInfoEntry OBJECT-TYPE + SYNTAX IsxModularDistSubFeedInfoEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing information about a specific distribution subfeed." + INDEX { isxModularDistSubFeedInfoSubIndex } + ::= { isxModularDistSubFeedInfoTable 1 } + +IsxModularDistSubFeedInfoEntry ::= + SEQUENCE { + isxModularDistSubFeedInfoSubIndex INTEGER, + isxModularDistSubFeedInfoName DisplayString, + isxModularDistSubFeedInfoLocation DisplayString, + isxModularDistSubFeedInfoBreakerRating INTEGER, + isxModularDistSubFeedInfoBreakerPosition INTEGER, + isxModularDistSubFeedInfoAlarmStatus INTEGER, + isxModularDistSubFeedInfoAlarmGeneration INTEGER, + isxModularDistSubFeedInfoThresholdMin INTEGER, + isxModularDistSubFeedInfoThresholdLow INTEGER, + isxModularDistSubFeedInfoThresholdHigh INTEGER, + isxModularDistSubFeedInfoThresholdMax INTEGER, + isxModularDistSubFeedInfoAlarmMinEnable INTEGER, + isxModularDistSubFeedInfoAlarmLowEnable INTEGER, + isxModularDistSubFeedInfoAlarmHighEnable INTEGER, + isxModularDistSubFeedInfoAlarmMaxEnable INTEGER, + isxModularDistSubFeedInfoBreakerAlarmEnable INTEGER, + isxModularDistSubFeedInfoTotalPower INTEGER, + isxModularDistSubFeedInfoKwhUsage INTEGER, + isxModularDistSubFeedInfoKwhReset INTEGER, + isxModularDistSubFeedInfoKwhResetDate DisplayString + } + +isxModularDistSubFeedInfoSubIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of an individual subfeed." + ::= { isxModularDistSubFeedInfoEntry 1 } + +isxModularDistSubFeedInfoName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A string describing the load equipment being supplied by this subfeed." + ::= { isxModularDistSubFeedInfoEntry 2 } + +isxModularDistSubFeedInfoLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A string describing the location of the equipment being supplied by this subfeed." + ::= { isxModularDistSubFeedInfoEntry 3 } + +isxModularDistSubFeedInfoBreakerRating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current rating of this subfeed breaker." + ::= { isxModularDistSubFeedInfoEntry 4 } + +isxModularDistSubFeedInfoBreakerPosition OBJECT-TYPE + SYNTAX INTEGER { + open (1), + closed (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The operational status of this breaker, either closed or open (including tripped)." + ::= { isxModularDistSubFeedInfoEntry 5 } + +isxModularDistSubFeedInfoAlarmStatus OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + warning (2), + critical (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The worst case alarm status for this subfeed." + ::= { isxModularDistSubFeedInfoEntry 6 } + +isxModularDistSubFeedInfoAlarmGeneration OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable all alarm generation related to this subfeed." + ::= { isxModularDistSubFeedInfoEntry 7 } + +isxModularDistSubFeedInfoThresholdMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When the current drops below this value a critical alarm will exist." + ::= { isxModularDistSubFeedInfoEntry 8 } + +isxModularDistSubFeedInfoThresholdLow OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When the current drops below this value a warning alarm will exist." + ::= { isxModularDistSubFeedInfoEntry 9 } + +isxModularDistSubFeedInfoThresholdHigh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When the current exceeds this value a warning alarm will exist." + ::= { isxModularDistSubFeedInfoEntry 10 } + +isxModularDistSubFeedInfoThresholdMax OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When the current exceeds this value a critical alarm will exist." + ::= { isxModularDistSubFeedInfoEntry 11 } + +isxModularDistSubFeedInfoAlarmMinEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable minimum current alarm generation for this subfeed." + ::= { isxModularDistSubFeedInfoEntry 12 } + +isxModularDistSubFeedInfoAlarmLowEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable low current alarm generation for this subfeed." + ::= { isxModularDistSubFeedInfoEntry 13 } + +isxModularDistSubFeedInfoAlarmHighEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable high current alarm generation for this subfeed." + ::= { isxModularDistSubFeedInfoEntry 14 } + +isxModularDistSubFeedInfoAlarmMaxEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable maximum current alarm generation for this subfeed." + ::= { isxModularDistSubFeedInfoEntry 15 } + +isxModularDistSubFeedInfoBreakerAlarmEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable breaker position alarms for this subfeed." + ::= { isxModularDistSubFeedInfoEntry 16 } + +isxModularDistSubFeedInfoTotalPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total power being supplied by this subfeed. Measured in tenths of kW." + ::= { isxModularDistSubFeedInfoEntry 17 } + +isxModularDistSubFeedInfoKwhUsage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total energy consumed by the load equipment fed by this subfeed. + This is the total since the date specified in the isxModularDistSubFeedInfoKwhResetDate + OID, and may be cleared using the isxModularDistSubFeedInfoKwhReset OID. + Measured in tenths of kWh." + ::= { isxModularDistSubFeedInfoEntry 18 } + +isxModularDistSubFeedInfoKwhReset OBJECT-TYPE + SYNTAX INTEGER { + no (1), + yes (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Writing yes to this OID will reset the total kWh usage shown + in the isxModularDistSubFeedInfoKwhUsage OID." + ::= { isxModularDistSubFeedInfoEntry 19 } + +isxModularDistSubFeedInfoKwhResetDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000." + ::= { isxModularDistSubFeedInfoEntry 20 } + +isxModularDistSubFeedLoadingTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the isxModularDistSubFeedLoadingTable." + ::= { isxModularDistSubFeeds 3 } + +isxModularDistSubFeedLoadingTable OBJECT-TYPE + SYNTAX SEQUENCE OF IsxModularDistSubFeedLoadingEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting subfeed phase loading information." + ::= { isxModularDistSubFeeds 4 } + +isxModularDistSubFeedLoadingEntry OBJECT-TYPE + SYNTAX IsxModularDistSubFeedLoadingEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing data for an individual subfeed." + INDEX { isxModularDistSubFeedLoadingSubIndex, isxModularDistSubFeedLoadingPhaseIndex } + ::= { isxModularDistSubFeedLoadingTable 1 } + +IsxModularDistSubFeedLoadingEntry ::= SEQUENCE { + isxModularDistSubFeedLoadingSubIndex INTEGER, + isxModularDistSubFeedLoadingPhaseIndex INTEGER, + isxModularDistSubFeedLoadingAlarmStatus INTEGER, + isxModularDistSubFeedLoadingCurrent INTEGER, + isxModularDistSubFeedLoadingPercent INTEGER, + isxModularDistSubFeedLoadingPower INTEGER + } + +isxModularDistSubFeedLoadingSubIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of an individual subfeed." + ::= { isxModularDistSubFeedLoadingEntry 1 } + +isxModularDistSubFeedLoadingPhaseIndex OBJECT-TYPE + SYNTAX INTEGER{ + phase1(1), + phase2(2), + phase3(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of each input phase entry in the table." + ::= { isxModularDistSubFeedLoadingEntry 2 } + +isxModularDistSubFeedLoadingAlarmStatus OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This is a bit map representing the active alarms for this subfeed: + + b0 - Minimum current threshold exceeded (critical) + b1 - Low current threshold exceeded (warning) + b2 - High current threshold exceeded (warning) + b3 - Maximum current threshold exceeded (critical) + b4 - Breaker is open (critical) + + If a bit is set, the corresponding alarm is active." + ::= { isxModularDistSubFeedLoadingEntry 3 } + +isxModularDistSubFeedLoadingCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current flowing though this subfeed phase. Measured in tenths of amps." + ::= { isxModularDistSubFeedLoadingEntry 4 } + +isxModularDistSubFeedLoadingPercent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The loading on this subfeed phase as a percentage of the subfeed's current rating. + Expressed in tenths of percent." + ::= { isxModularDistSubFeedLoadingEntry 5 } + +isxModularDistSubFeedLoadingPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The power being supplied by this subfeed phase. Measured in tenths of kW." + ::= { isxModularDistSubFeedLoadingEntry 6 } + +-- Distribution System Output Voltage + +isxModularDistSysOutputVoltageNominalLineToNeutral OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal line-to-neutral voltage available at the distribution panel." + ::= { isxModularDistSysVoltage 1 } + +isxModularDistSysOutputVoltageNominalLineToLine OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal line-to-line voltage available at the distribution panel." + ::= { isxModularDistSysVoltage 2 } + +isxModularDistSysOutputNominalFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal system output frequency. Measured in tenths of Hertz." + ::= { isxModularDistSysVoltage 3 } + +isxModularDistSysOutputFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The system output frequency in tenths of Hertz. + -1 if not available." + ::= { isxModularDistSysVoltage 4 } + +isxModularDistSysOutputVoltageMonitoring OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + present (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not output voltage alarm generation is present." + ::= { isxModularDistSysVoltage 5 } + +isxModularDistSysOutputVoltageThresholdMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When the line-to-neutral voltage of any phase drops below this value a critical alarm will exist. + Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. + This value is returned as a positive number which represents a negative percentage. + A value of -1 indicates that the threshold is not available in the device." + ::= { isxModularDistSysVoltage 6 } + +isxModularDistSysOutputVoltageThresholdLow OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When the line-to-neutral voltage of any phase drops below this value a warning alarm will exist. + Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. + This value is returned as a positive number which represents a negative percentage. + A value of -1 indicates that the threshold is not available in the device." + ::= { isxModularDistSysVoltage 7 } + +isxModularDistSysOutputVoltageThresholdHigh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When the line-to-neutral voltage of any phase exceeds this value a warning alarm will exist. + Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. + A value of -1 indicates that the threshold is not available in the device." + ::= { isxModularDistSysVoltage 8 } + +isxModularDistSysOutputVoltageThresholdMax OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When the line-to-neutral voltage of any phase exceeds this value a critical alarm will exist. + Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. + A value of -1 indicates that the threshold is not available in the device." + ::= { isxModularDistSysVoltage 9 } + +isxModularDistSysOutputVoltageAlarmMinEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable minimum voltage alarm generation for the distribution panel." + ::= { isxModularDistSysVoltage 10 } + +isxModularDistSysOutputVoltageAlarmLowEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable low voltage alarm generation for the distribution panel." + ::= { isxModularDistSysVoltage 11 } + +isxModularDistSysOutputVoltageAlarmHighEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable high voltage alarm generation for the distribution panel." + ::= { isxModularDistSysVoltage 12 } + +isxModularDistSysOutputVoltageAlarmMaxEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable maximum voltage alarm generation for the distribution panel." + ::= { isxModularDistSysVoltage 13 } + +isxModularDistSysOutputVoltageFrequencyTolerance OBJECT-TYPE + SYNTAX INTEGER{ + freqToleranceOff (1), + freqTolerancePointTwo (2), + freqTolerancePointFive (3), + freqToleranceOne (4), + freqToleranceOnePointFive (5), + freqToleranceTwo (6), + freqToleranceThree (7), + freqToleranceFour (8), + freqToleranceFive (9), + freqToleranceNine (10), + freqToleranceNotAvailable (11) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The circuit panel output frequency tolerance in Hertz. + When the system output frequency deviates from the nominal by more than this range, + a critical alarm will be generated." + ::= { isxModularDistSysVoltage 14 } + +isxModularDistSysVoltageTable OBJECT-TYPE + SYNTAX SEQUENCE OF IsxModularDistSysVoltageEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting the system output voltage information." + ::= { isxModularDistSysVoltage 15 } + +isxModularDistSysVoltageEntry OBJECT-TYPE + SYNTAX IsxModularDistSysVoltageEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing data for an individual system output phase." + INDEX { isxModularDistSysVoltagePhaseIndex } + ::= { isxModularDistSysVoltageTable 1 } + +IsxModularDistSysVoltageEntry ::= + SEQUENCE { + isxModularDistSysVoltagePhaseIndex INTEGER, + isxModularDistSysVoltageAlarmStatus INTEGER, + isxModularDistSysVoltageLtoN INTEGER, + isxModularDistSysVoltageLtoL INTEGER + } + +isxModularDistSysVoltagePhaseIndex OBJECT-TYPE + SYNTAX INTEGER{ + phase1(1), + phase2(2), + phase3(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of each phase entry in the table." + ::= { isxModularDistSysVoltageEntry 1 } + +isxModularDistSysVoltageAlarmStatus OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This is a bit map representing the active alarms for this output phase: + + b0 - Minimum voltage threshold exceeded (critical) + b1 - Low voltage threshold exceeded (warning) + b2 - High voltage threshold exceeded (warning) + b3 - Maximum voltage threshold exceeded (critical) + + If a bit is set, the corresponding alarm is active." + ::= { isxModularDistSysVoltageEntry 2 } + +isxModularDistSysVoltageLtoN OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Line-to-neutral system output voltage available at the distribution panel. + Measured in tenths of Volts." + ::= { isxModularDistSysVoltageEntry 3 } + +isxModularDistSysVoltageLtoL OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Line-to-line system output voltage available at the distribution panel. + Measured in tenths of Volts." + ::= { isxModularDistSysVoltageEntry 4 } + + +-- Distribution System Total Output Current + +isxModularDistSysCurrentRating OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The 100 percent current rating of the distribution panel." + ::= { isxModularDistSysCurrent 1 } + +isxModularDistSysCurrentMonitoring OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + present (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not total output current measurements and alarm generation are present." + ::= { isxModularDistSysCurrent 2 } + +isxModularDistSysCurrentThresholdMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When total system current in any phase drops below this value a critical alarm will exist. + Specified as a percent of the panel rating, isxModularDistSysCurrentRating. + A value of -1 indicates that the threshold is not available in the device." + ::= { isxModularDistSysCurrent 3 } + +isxModularDistSysCurrentThresholdLow OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When total system current in any phase drops below this value a warning alarm will exist. + Specified as a percent of the panel rating, isxModularDistSysCurrentRating. + A value of -1 indicates that the threshold is not available in the device." + ::= { isxModularDistSysCurrent 4 } + +isxModularDistSysCurrentThresholdHigh OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When total system current in any phase exceeds this value a warning alarm will exist. + Specified as a percent of the panel rating, isxModularDistSysCurrentRating. + A value of -1 indicates that the threshold is not available in the device." + ::= { isxModularDistSysCurrent 5 } + +isxModularDistSysCurrentThresholdMax OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "When total system current in any phase exceeds this value a critical alarm will exist. + Specified as a percent of the panel rating, isxModularDistSysCurrentRating. + A value of -1 indicates that the threshold is not available in the device." + ::= { isxModularDistSysCurrent 6 } + +isxModularDistSysCurrentAlarmMinEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable minimum total output current alarm generation." + ::= { isxModularDistSysCurrent 7 } + +isxModularDistSysCurrentAlarmLowEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable low total output current alarm generation." + ::= { isxModularDistSysCurrent 8 } + +isxModularDistSysCurrentAlarmHighEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable high total output current alarm generation." + ::= { isxModularDistSysCurrent 9 } + +isxModularDistSysCurrentAlarmMaxEnable OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable maximum total output current alarm generation." + ::= { isxModularDistSysCurrent 10 } + +isxModularDistSysCurrentTable OBJECT-TYPE + SYNTAX SEQUENCE OF IsxModularDistSysCurrentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting the total system phase current information." + ::= { isxModularDistSysCurrent 11 } + +isxModularDistSysCurrentEntry OBJECT-TYPE + SYNTAX IsxModularDistSysCurrentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing data for an individual system output phase." + INDEX { isxModularDistSysCurrentPhaseIndex } + ::= { isxModularDistSysCurrentTable 1 } + +IsxModularDistSysCurrentEntry ::= + SEQUENCE { + isxModularDistSysCurrentPhaseIndex INTEGER, + isxModularDistSysCurrentAlarmStatus INTEGER, + isxModularDistSysCurrentAmps INTEGER, + isxModularDistSysCurrentPercent INTEGER + } + +isxModularDistSysCurrentPhaseIndex OBJECT-TYPE + SYNTAX INTEGER{ + phase1(1), + phase2(2), + phase3(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of each phase entry in the table." + ::= { isxModularDistSysCurrentEntry 1 } + +isxModularDistSysCurrentAlarmStatus OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This is a bit map representing the active alarms for this output phase: + + b0 - Minimum current threshold exceeded (critical) + b1 - Low current threshold exceeded (warning) + b2 - High current threshold exceeded (warning) + b3 - Maximum current threshold exceeded (critical) + + If a bit is set, the corresponding alarm is active." + ::= { isxModularDistSysCurrentEntry 2 } + +isxModularDistSysCurrentAmps OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current flowing though this system output phase. Measured in tenths of amps." + ::= { isxModularDistSysCurrentEntry 3 } + +isxModularDistSysCurrentPercent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The loading on this system output phase as a percentage of the panel current rating. + Expressed in tenths of percent." + ::= { isxModularDistSysCurrentEntry 4 } + +-- Distribution System Total Output Power + +isxModularDistSysPowerTotal OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total system power being supplied. Measured in tenths of kW." + ::= { isxModularDistSysPower 1 } + +isxModularDistSysPowerKwhUsage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total system energy consumed by the load equipment. + This is the total since the date specified in the isxModularDistSysOutputKwhResetDate + OID, and may be cleared using the isxModularDistSysOutputKwhReset OID. + Measured in tenths of kWh." + ::= { isxModularDistSysPower 2 } + +isxModularDistSysPowerKwhReset OBJECT-TYPE + SYNTAX INTEGER { + no (1), + yes (2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Writing yes to this OID will reset the total kWh usage shown + in the isxModularDistSysPowerKwhUsage OID." + ::= { isxModularDistSysPower 3 } + +isxModularDistSysPowerKwhResetDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000." + ::= { isxModularDistSysPower 4 } + +isxModularDistSysPowerTable OBJECT-TYPE + SYNTAX SEQUENCE OF IsxModularDistSysPowerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting the total system phase power loading information." + ::= { isxModularDistSysPower 5 } + +isxModularDistSysPowerEntry OBJECT-TYPE + SYNTAX IsxModularDistSysPowerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry containing data for an individual system output phase." + INDEX { isxModularDistSysPowerPhaseIndex } + ::= { isxModularDistSysPowerTable 1 } + +IsxModularDistSysPowerEntry ::= + SEQUENCE { + isxModularDistSysPowerPhaseIndex INTEGER, + isxModularDistSysPowerKw INTEGER, + isxModularDistSysPowerKwhPhaseUsage INTEGER + } + +isxModularDistSysPowerPhaseIndex OBJECT-TYPE + SYNTAX INTEGER{ + phase1(1), + phase2(2), + phase3(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of each phase entry in the table." + ::= { isxModularDistSysPowerEntry 1 } + +isxModularDistSysPowerKw OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The power being supplied by this system output phase. Measured in tenths of kW." + ::= { isxModularDistSysPowerEntry 2 } + +isxModularDistSysPowerKwhPhaseUsage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The energy consumed by the load equipment on this system output phase. + This is the total since the date specified in the isxModularDistSysPowerKwhResetDate + OID, and may be cleared using the isxModularDistSysPowerKwhReset OID. + Measured in tenths of kWh." + ::= { isxModularDistSysPowerEntry 3 } + +-- the isxModularPduIdent group + +isxModularPduIdentModelNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the model number of the PDU. + This value is set at the factory." + ::= { isxModularPduIdent 1 } + +isxModularPduIdentSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the serial number of the PDU. + This value is set at the factory." + ::= { isxModularPduIdent 2 } + +isxModularPduIdentDateOfManufacture OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The date when the PDU was manufactured in mm/dd/yyyy format. + This value is set at the factory." + ::= { isxModularPduIdent 3 } + +isxModularPduIdentMonitorCardSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A character string identifying the serial number of the PDU monitor card. + This value is set at the factory." + ::= { isxModularPduIdent 4 } + +isxModularPduIdentMonitorCardHardwareRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware revision of the PDU monitor card. + This value is set at the factory." + ::= { isxModularPduIdent 5 } + +isxModularPduIdentMonitorCardFirmwareAppRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ID string identifying the application firmware revision of the + PDU monitor card." + ::= { isxModularPduIdent 6 } + +isxModularPduIdentMonitorCardFirmwareAppOSRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An ID string identifying the application operating system firmware revision of the + PDU monitor card." + ::= { isxModularPduIdent 7 } + +-- the isxModularPduDevice group + +isxModularPduDeviceTransformerPresent OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + isoXfmrPresent (2), + autoXfmrPresent (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the type of transformer present in this PDU." + ::= { isxModularPduDevice 1 } + +isxModularPduDeviceServiceType OBJECT-TYPE + SYNTAX INTEGER { + threeWire (1), + fourWire (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of utility input to the PDU. Either 3 wires (delta), or 4 wires (wye)." + ::= { isxModularPduDevice 2 } + +isxModularPduDeviceFansPresent OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + present (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether or not cooling fans are installed in the PDU." + ::= { isxModularPduDevice 3 } + +isxModularPduDeviceNominalMainInputVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The nominal main input voltage to the system. Measured in Volts, + line-to-line for a 3-wire (delta) service or line-to-neutral for a + 4-wire (wye) service. -1 if main input voltage is not being measured." + ::= { isxModularPduDevice 4 } + +isxModularPduAlarmStatus OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + warning (2), + critical (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The overall status (worst case) of this PDU." + ::= { isxModularPduStatus 1 } + +isxModularPduTransformerTempStatus OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + overtemp (2), + noTransformerPresent (3), + unknown (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates if the PDU isolation transformer is over temperature." + ::= { isxModularPduStatus 2 } + +isxModularPduFanStatus OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + failed (2), + noCoolingFansPresent (3), + unknown (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates if one or more of the PDU's cooling fans have failed." + ::= { isxModularPduStatus 3 } + + +-- Universal Input / Output (uio) + +-- uio Sensor Status Table + +uioSensorStatusTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the uioSensorStatusTable." + ::= { uioSensor 1 } + +uioSensorStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF UIOSensorStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting sensor status information." + ::= { uioSensor 2 } + +uioSensorStatusEntry OBJECT-TYPE + SYNTAX UIOSensorStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit from which to get data." + INDEX { uioSensorStatusPortID, uioSensorStatusSensorID } + ::= { uioSensorStatusTable 1 } + +UIOSensorStatusEntry ::= + SEQUENCE { + uioSensorStatusPortID INTEGER, + uioSensorStatusSensorID INTEGER, + uioSensorStatusSensorName DisplayString, + uioSensorStatusSensorLocation DisplayString, + uioSensorStatusTemperatureDegF INTEGER, + uioSensorStatusTemperatureDegC INTEGER, + uioSensorStatusHumidity INTEGER, + uioSensorStatusViolationStatus INTEGER, + uioSensorStatusAlarmStatus INTEGER, + uioSensorStatusCommStatus INTEGER + } + +uioSensorStatusPortID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The ID of the Universal IO port to which the sensor is attached." + ::= { uioSensorStatusEntry 1 } + +uioSensorStatusSensorID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The ID of the sensor." + ::= { uioSensorStatusEntry 2 } + +uioSensorStatusSensorName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The sensor name." + ::= { uioSensorStatusEntry 3 } + +uioSensorStatusSensorLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The location of the sensor." + ::= { uioSensorStatusEntry 4 } + +uioSensorStatusTemperatureDegF OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The sensor's current temperature reading in tenths of degrees Fahrenheit." + ::= { uioSensorStatusEntry 5 } + +uioSensorStatusTemperatureDegC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The sensor's current temperature reading in tenths of degrees Celsius." + ::= { uioSensorStatusEntry 6 } + +uioSensorStatusHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current humidity reading in tenths of percent from the sensor." + ::= { uioSensorStatusEntry 7 } + +uioSensorStatusViolationStatus OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The violation status of the sensor. This integer should be interpreted + as a bit map, with each bit representing the presence or absence of + the specific alarm conditions listed below. The bit will be '1' if + the condition is present, and '0' if the condition is not present. + + Bit Hex. Value Description + 1 0x0001 Maximum temperature exceeded. + 2 0x0002 High temperature exceeded. + 3 0x0004 Low temperature exceeded. + 4 0x0008 Minimum temperature exceeded. + 5 0x0010 Short-term increasing temperature rate exceeded (Not used). + 6 0x0020 Short-term decreasing temperature rate exceeded (Not used). + 7 0x0040 Long-term increasing temperature rate exceeded (Not used). + 8 0x0080 Long-term decreasing temperature rate exceeded (Not used). + 9 0x0100 Maximum humidity exceeded. + 10 0x0200 High humidity exceeded. + 11 0x0400 Low humidity exceeded. + 12 0x0800 Minimum humidity exceeded." + ::= { uioSensorStatusEntry 8 } + +uioSensorStatusAlarmStatus OBJECT-TYPE + SYNTAX INTEGER { + uioNormal (1), + uioWarning (2), + uioCritical (3), + sensorStatusNotApplicable (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The alarm status of the sensor." + ::= { uioSensorStatusEntry 9 } + +uioSensorStatusCommStatus OBJECT-TYPE + SYNTAX INTEGER { + notInstalled (1), + commsOK (2), + commsLost (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The communications status of the sensor." + ::= { uioSensorStatusEntry 10 } + + +-- uio Input Contact Status Table + +uioInputContactStatusTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the uioInputContactStatusTable." + ::= { uioInputContact 1 } + +uioInputContactStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF UIOInputContactStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting input contact status information." + ::= { uioInputContact 2 } + +uioInputContactStatusEntry OBJECT-TYPE + SYNTAX UIOInputContactStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The input contact from which to get data." + INDEX { uioInputContactStatusPortID, uioInputContactStatusContactID } + ::= { uioInputContactStatusTable 1 } + +UIOInputContactStatusEntry ::= + SEQUENCE { + uioInputContactStatusPortID INTEGER, + uioInputContactStatusContactID INTEGER, + uioInputContactStatusContactName DisplayString, + uioInputContactStatusContactLocation DisplayString, + uioInputContactStatusCurrentState INTEGER, + uioInputContactStatusAlarmStatus INTEGER, + uioInputContactStatusCommStatus INTEGER + } + +uioInputContactStatusPortID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The ID of the port to which the input contact is attached." + ::= { uioInputContactStatusEntry 1 } + +uioInputContactStatusContactID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The ID of the input contact on the module." + ::= { uioInputContactStatusEntry 2 } + +uioInputContactStatusContactName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The input contact name." + ::= { uioInputContactStatusEntry 3 } + +uioInputContactStatusContactLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The location of the input contact." + ::= { uioInputContactStatusEntry 4 } + +uioInputContactStatusCurrentState OBJECT-TYPE + SYNTAX INTEGER { + uioInputClosed (1), + uioInputOpen (2), + uioInputDisabled (3), + inputStateNotApplicable (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current state of the input contact. " + ::= { uioInputContactStatusEntry 5 } + +uioInputContactStatusAlarmStatus OBJECT-TYPE + SYNTAX INTEGER { + uioNormal (1), + uioWarning (2), + uioCritical (3), + inputStatusNotApplicable (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The alarm status of the input contact." + ::= { uioInputContactStatusEntry 6 } + +uioInputContactStatusCommStatus OBJECT-TYPE + SYNTAX INTEGER { + notInstalled (1), + commsOK (2), + commsLost (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The communications status of the input contact." + ::= { uioInputContactStatusEntry 7 } + + +-- uio Output Relay Status Table + +uioOutputRelayStatusTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of entries in the uioOutputRelayStatusTable." + ::= { uioOutputRelay 1 } + +uioOutputRelayStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF UIOOutputRelayStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Allows for getting output relay status information." + ::= { uioOutputRelay 2 } + +uioOutputRelayStatusEntry OBJECT-TYPE + SYNTAX UIOOutputRelayStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The unit from which to get data." + INDEX { uioOutputRelayStatusPortID, uioOutputRelayStatusRelayID } + ::= { uioOutputRelayStatusTable 1 } + +UIOOutputRelayStatusEntry ::= + SEQUENCE { + uioOutputRelayStatusPortID INTEGER, + uioOutputRelayStatusRelayID INTEGER, + uioOutputRelayStatusRelayName DisplayString, + uioOutputRelayStatusRelayLocation DisplayString, + uioOutputRelayStatusCurrentState INTEGER, + uioOutputRelayStatusAlarmStatus INTEGER, + uioOutputRelayStatusCommStatus INTEGER + } + +uioOutputRelayStatusPortID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The ID of the module to which the output relay is attached." + ::= { uioOutputRelayStatusEntry 1 } + +uioOutputRelayStatusRelayID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The ID of the output relay on the module." + ::= { uioOutputRelayStatusEntry 2 } + +uioOutputRelayStatusRelayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output relay name." + ::= { uioOutputRelayStatusEntry 3 } + +uioOutputRelayStatusRelayLocation OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The location of the output relay." + ::= { uioOutputRelayStatusEntry 4 } + +uioOutputRelayStatusCurrentState OBJECT-TYPE + SYNTAX INTEGER { + uioOutputClosed (1), + uioOutputOpen (2), + outputStateNotApplicable (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current state of the output relay." + ::= { uioOutputRelayStatusEntry 5 } + +uioOutputRelayStatusAlarmStatus OBJECT-TYPE + SYNTAX INTEGER { + uioNormal (1), + uioWarning (2), + uioCritical (3), + inputStatusNotApplicable (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The alarm status of the output relay." + ::= { uioOutputRelayStatusEntry 6 } + +uioOutputRelayStatusCommStatus OBJECT-TYPE + SYNTAX INTEGER { + notInstalled (1), + commsOK (2), + commsLost (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The communications status of the output relay." + ::= { uioOutputRelayStatusEntry 7 } + + +-- Traps +-- Annotations are provided for Novell's NMS product +-- +-- Each trap has at least one variable (mtrapargsString) which always appears +-- as the last variable in the list. This variable contains either a static +-- or dynamically-constructed string which provides an enhanced description of +-- the trap's purpose and any pertinent information about the trap. + +communicationLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: Communication to the UPS has been lost. Steps + to reestablish communication are in progress." + --#TYPE "APC UPS: Communication lost" + --#SUMMARY "Communication lost between the agent and the UPS." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 1 + +upsOverload TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: The UPS has sensed a load greater than 100 percent + of its rated capacity." + --#TYPE "APC UPS: Overload" + --#SUMMARY "The UPS has sensed a load greater than 100 percent of its rated capacity." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 2 + +upsDiagnosticsFailed TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: The UPS failed its internal diagnostic self-test." + --#TYPE "APC UPS: Failed self-test" + --#SUMMARY "The UPS has failed its internal self-test." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 3 + +upsDischarged TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: The UPS batteries are discharged; if utility power fails + an immediate low battery condition will exist. Sufficient runtime + for necessary action cannot be guaranteed." + --#TYPE "APC UPS: batteries are discharged" + --#SUMMARY "The UPS batteries are discharged." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 4 + +upsOnBattery TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The UPS has switched to battery backup power." + --#TYPE "APC UPS: On battery" + --#SUMMARY "The UPS has switched to battery backup power." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 5 + +smartBoostOn TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The UPS has enabled SmartBoost(TM)." + --#TYPE "APC UPS: SmartBoost(TM)" + --#SUMMARY "The UPS has enabled SmartBoost(TM); low incoming line voltage." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 6 + +lowBattery TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: The UPS batteries are low and will soon be exhausted. + If utility power is not restored the UPS will put itself + to 'sleep' and immediately cut power to the load." + --#TYPE "APC UPS: Low battery" + --#SUMMARY "The UPS system's batteries are low and will soon be exhausted." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 7 + +communicationEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Communication with the UPS has been established." + --#TYPE "APC UPS: Communication established" + --#SUMMARY "UPS communication has been established." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 8 + +powerRestored TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Utility power has been restored." + --#TYPE "APC UPS: Utility power restored" + --#SUMMARY "Returned from battery backup power; utility power restored." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 9 + +upsDiagnosticsPassed TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The UPS passed its internal self-test." + --#TYPE "APC UPS: Passed self-test" + --#SUMMARY "The UPS passed internal self-test." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 10 + +returnFromLowBattery TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The UPS has returned from a low battery + condition." + --#TYPE "APC UPS: Returned from Low-Battery condition" + --#SUMMARY "The UPS has returned from a Low-Battery condition." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 11 + +upsTurnedOff TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The UPS has been turned 'off' by the management station." + --#TYPE "APC UPS: Turned off" + --#SUMMARY "The UPS has been switched off by a management station." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE NONOPERATIONAL + ::= 12 + +upsSleeping TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The UPS is entering 'sleep' mode. Power + to the load will be cut off." + --#TYPE "APC UPS: Entered sleep mode" + --#SUMMARY "The UPS entered sleep mode. Power to the load will be cut off." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE NONOPERATIONAL + ::= 13 + +upsWokeUp TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATION: The UPS has returned from 'sleep' mode. Power + to the load has been restored." + --#TYPE "APC UPS: Wake up" + --#SUMMARY "The UPS has returned from sleep mode. Power to the load has been restored." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 14 + +upsRebootStarted TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The UPS has started its reboot sequence. + The UPS will reboot itself at this time." + --#TYPE "APC UPS: Starting reboot" + --#SUMMARY "The UPS has started its reboot sequence." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE NONOPERATIONAL + ::= 15 + +upsDipSwitchChanged TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The dip switch settings on the UPS have been + changed, possibly altering UPS performance." + --#TYPE "APC UPS: DIP switch altered" + --#SUMMARY "The DIP switch settings on the UPS have been changed." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 16 + +upsBatteryNeedsReplacement TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: The batteries of the UPS need immediate replacement." + --#TYPE "APC UPS: UPS batteries need replacement" + --#SUMMARY "The UPS batteries require immediate replacement." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 17 + + +-- the Environmental Monitor traps + +contactFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: One of the contacts on the Environmental Monitor has + changed from its default position. The first variable is + the contact number that is faulted." + --#TYPE "APC Environment: Contact fault" + --#SUMMARY "An Environment contact closure has faulted." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 18 + +contactFaultResolved TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A fault on one of the Environmental Monitor contacts + has been resolved. The first variable is + the contact number that has been resolved." + --#TYPE "APC Environment: Contact fault cleared." + --#SUMMARY "A Environment contact closure has returned to it's default state." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 19 + +-- the Matrix-UPS traps + +hardwareFailureBypass TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: UPS on bypass due to internal fault" + --#TYPE "APC UPS: On bypass due to internal fault" + --#SUMMARY "The UPS is on bypass due to an internal fault." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 20 + +softwareBypass TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: UPS on bypass - user set via software or panel" + --#TYPE "APC UPS: On bypass by user via software or panel" + --#SUMMARY "UPS put on bypass by user via software or front UPS panel." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 21 + +switchedBypass TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: UPS on bypass - initiated by user" + --#TYPE "APC UPS: On bypass initiated by user" + --#SUMMARY "UPS put on bypass by user." + + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 22 + +returnFromBypass TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: UPS has returned from bypass" + --#TYPE "APC UPS: UPS has returned from bypass" + --#SUMMARY "The UPS has returned from bypass mode." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 23 + +bypassPowerSupplyFailure TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: Base module bypass power supply needs repair" + --#TYPE "APC UPS: Base module bypass power supply needs repair" + --#SUMMARY "The base module bypass power supply needs repair." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE NONOPERATIONAL + ::= 24 + +baseFanFailure TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: Base module fan needs repair" + --#TYPE "APC UPS: Base module fan needs repair" + --#SUMMARY "The base module fan needs repair." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE NONOPERATIONAL + ::= 25 + +batteryPackCommLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: Check installation of external battery packs signal cable" + --#TYPE "APC UPS: Communication lost with battery packs" + --#SUMMARY "Communication lost with external battery packs, check battery signal cable." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 26 + +batteryPackCommEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: UPS is communicating with the external battery packs." + --#TYPE "APC UPS: Communication established with battery packs" + --#SUMMARY "Communication established with external battery packs." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 27 + +calibrationStart TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A battery calibration test has been initiated on the UPS." + --#TYPE "APC UPS: Calibration initiated" + --#SUMMARY "A battery run time calibration test has been initiated." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 28 + +-- Misc. Traps + +restartAgent TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Agent restarting as commanded by manager." + --#TYPE "APC SNMP Agent: Agent restarting" + --#SUMMARY "Agent restarting as commanded by manager." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 29 + +upsTurnedOn TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A UPS is turned on." + --#TYPE "APC UPS: A UPS is turned on." + --#SUMMARY " A UPS is turned on." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 30 + +smartAvrReducing TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The UPS is reducing the line voltage via SmartTrim(TM)." + --#TYPE "APC UPS: SmartTrim(TM) reducing" + --#SUMMARY "The UPS has enabled SmartTrim(TM) voltage reduction." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 31 + +codeAuthenticationDone TRAP-TYPE + ENTERPRISE apc + VARIABLES { mconfigTFTPServerIP, newCodeAuthentViaTFTP } + DESCRIPTION + "INFORMATIONAL: Authentication on agent code image is done." + --#TYPE "APC CODE: Authentication on agent code image is done." + --#SUMMARY "Authentication on agent code image is done." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 32 + +upsOverloadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The overload condition has been cleared." + --#TYPE "APC UPS: Overload cleared." + --#SUMMARY "The overload condition has been cleared. ." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 33 + +smartBoostOff TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The UPS has returned from SmartBoost(TM)." + --#TYPE "APC UPS: SmartBoost(TM) off." + --#SUMMARY "The UPS has returned from SmartBoost(TM)." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 34 + +smartAvrReducingOff TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The UPS has returned from SmartTrim(TM)." + --#TYPE "APC UPS: SmartTrim(TM) reducing off" + --#SUMMARY "The UPS has returned from SmartTrim(TM) voltage reduction." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 35 + +upsBatteryReplaced TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A bad battery fault has been cleared." + --#TYPE "APC UPS: Bad battery replaced" + --#SUMMARY "The UPS has returned from a bad battery fault." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 36 + +calibrationEnd TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The UPS has finished calibrating." + --#TYPE "APC UPS: Calibration end" + --#SUMMARY "The UPS has finished calibrating" + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 37 + +dischargeCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A UPS discharge condition has been cleared." + --#TYPE "APC UPS: Discharge cleared." + --#SUMMARY "The UPS discharge condition has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 38 + +gracefulShutdown TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A graceful shutdown has been initiated." + --#TYPE "APC UPS: A graceful shutdown has been initiated." + --#SUMMARY "A graceful shutdown has been initiated." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 39 + + +outletOn TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUOutletControlIndex } + DESCRIPTION + "WARNING: The specified PDU outlet has turned on. + If sPDUOutletControlIndex equals zero, then all outlets have + turned on." + --#TYPE "APC PDU: Outlet has been turned on." + --#SUMMARY "Outlet has been turned on" + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 41 + + +outletOff TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUOutletControlIndex } + DESCRIPTION + "WARNING: The specified PDU outlet has turned off. + If sPDUOutletControlIndex equals zero, then all outlets + have turned off." + --#TYPE "APC PDU: Outlet has turned off." + --#SUMMARY "Outlet has turned off." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 42 + +outletReboot TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUOutletControlIndex } + DESCRIPTION + "WARNING: The specified PDU outlet has rebooted. + If sPDUOutletControlIndex equals zero, then all outlets + have rebooted." + --#TYPE "APC PDU: Outlet has rebooted." + --#SUMMARY "Outlet has rebooted." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 43 + +configChangeSNMP TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The SNMP configuration has been changed." + --#TYPE "APC: The SNMP configuration has been changed." + --#SUMMARY "The SNMP configuration has been changed." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 44 + + +configChangeOutlet TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUOutletConfigIndex } + DESCRIPTION + "WARNING: The specified PDU outlet has changed configuration. + If sPDUOutletConfigIndex equals zero, then the Master outlet + has changed configuration." + --#TYPE "APC PDU: Outlet configuration has been changed." + --#SUMMARY "Outlet configuration has been changed." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 45 + +accessViolationConsole TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: Someone has attempted to login via the console with the incorrect password." + --#TYPE "APC: Access violation via the console." + --#SUMMARY "Three unsuccessful logins have been attempted via the console." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 46 + +accessViolationHTTP TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: Someone has attempted to login via HTTP with the incorrect password." + --#TYPE "APC: Access violation via HTTP." + --#SUMMARY "An unsuccessful attempt to login via HTTP." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 47 + +passwordChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The password for the device has been changed." + --#TYPE "APC: Password change for the device." + --#SUMMARY "Someone has changed the password on the device." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 48 + +badVoltage TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The output voltage is not within acceptable range." + --#TYPE "APC UPS: Bad output voltage." + --#SUMMARY "The output voltage is not within acceptable range." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 49 + +badVoltageCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The output voltage has returned to an acceptable level." + --#TYPE "APC UPS: The bad voltage output condition has been cleared." + --#SUMMARY "The output voltage has returned to an acceptable level." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 50 + +chargerFailure TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The battery charger has failed." + --#TYPE "APC UPS: The battery charger has failed." + --#SUMMARY "The battery charger has failed." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 51 + +chargerFailureCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The battery charger failure condition has been cleared." + --#TYPE "APC UPS: The battery charger failure condition cleared" + --#SUMMARY "The battery charger failure condition has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 52 + +batteryOverTemperature TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The battery temperature threshold has been violated." + --#TYPE "APC UPS: The battery temperature threshold has been violated." + --#SUMMARY "The battery temperature threshold has been violated." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 53 + +batteryOverTemperatureCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The battery over temperature has been cleared." + --#TYPE "APC UPS: The battery over temperature has been cleared." + --#SUMMARY "The battery over temperature has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 54 + + smartRelayFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: SmartBoost(TM) or SmartTrim(TM) relay fault." + --#TYPE "APC UPS: SmartBoost(TM) or SmartTrim(TM) relay fault." + --#SUMMARY "SmartBoost(TM) or SmartTrim(TM) relay fault." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 55 + +smartRelayFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: SmartBoost(TM) or SmartTrim(TM) relay fault has been cleared." + --#TYPE "APC UPS: SmartBoost(TM) or SmartTrim(TM) relay fault cleared." + --#SUMMARY "SmartBoost(TM) or SmartTrim(TM) relay fault has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 56 + +humidityThresholdViolation1 TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Probe 1 humidity threshold violated. The + first variable is the current humidity." + --#TYPE "APC Environmental Monitor: Probe 1 humidity threshold violation" + --#SUMMARY "A humidity threshold has been violated on probe 1." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 57 + +humidityThresholdViolationCleared1 TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 1." + --#TYPE "APC Environmental Monitor: Probe 1 humidity violation cleared" + --#SUMMARY "A humidity threshold violation has been cleared on probe 1." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 58 + +temperatureThresholdViolation1 TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: An Environmental Monitor temperature threshold has been violated on probe 1. + The first variable is the current temperature." + --#TYPE "APC Environmental Monitor: Probe 1 temperature violation" + --#SUMMARY "A temperature threshold has been violated on probe 1." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 59 + +temperatureThresholdViolationCleared1 TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 1." + --#TYPE "APC Environmental Monitor: Probe 1 temperature violation cleared" + --#SUMMARY "A temperature threshold violation has been cleared on probe 1." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 60 + +humidityThresholdViolation2 TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: An Environmental Monitor humidity threshold has been violated on probe 2. + The first variable is the current humidity." + --#TYPE "APC Environmental Monitor: Probe 2 humidity violation" + --#SUMMARY "A humidity threshold has been violated on probe 2." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 61 + +humidityThresholdViolationCleared2 TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 2." + --#TYPE "APC Environmental Monitor: Probe 2 humidity violation cleared" + --#SUMMARY "A humidity threshold violation has been cleared on probe 2." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 62 + +temperatureThresholdViolation2 TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: An Environmental Monitor temperature threshold has been violated on probe 2. + The first variable is the current temperature." + --#TYPE "APC Environmental Monitor: Probe 2 temperature violation" + --#SUMMARY "A temperature threshold has been violated on probe 2." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 63 + +temperatureThresholdViolationCleared2 TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 2." + --#TYPE "APC Environmental Monitor: Probe 2 temperature violation cleared" + --#SUMMARY "A temperature threshold violation has been cleared on probe 2." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 64 + +mupsCommunicationEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Communication with the Environmental Monitor has been established." + --#TYPE "APC Environmental Monitor: Communication established" + --#SUMMARY "Communication established between the agent and the Environmental Monitor." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 65 + +mupsCommunicationLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: Communication to the Environmental Monitor has been lost. Steps + to reestablish communication are in progress." + --#TYPE "APC Environmental Monitor: Communication failure" + --#SUMMARY "Communication lost between the agent and the Environmental Monitor." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 66 + +batteryIncrease TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The number of batteries has increased." + --#TYPE "APC UPS: The number of batteries has increased." + --#SUMMARY "The number of batteries has increased." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 67 + +batteryDecrease TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The number of batteries has decreased." + --#TYPE "APC UPS: The number of batteries has decreased." + --#SUMMARY "The number of batteries has decreased." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 68 + +powerModuleIncrease TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The number of power modules has increased." + --#TYPE "APC UPS: The number of power modules has increased." + --#SUMMARY "The number of power modules has increased." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 69 + +powerModuleDecrease TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The number of power modules has decreased." + --#TYPE "APC UPS: The number of power modules has decreased." + --#SUMMARY "The number of power modules has decreased." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 70 + +intelligenceModuleInserted TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An intelligence module has been inserted." + --#TYPE "APC UPS: An intelligence module has been inserted." + --#SUMMARY "An intelligence module has been inserted." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 71 + +intelligenceModuleRemoved TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An intelligence module has been removed." + --#TYPE "APC UPS: An intelligence module has been removed." + --#SUMMARY "An intelligence module has been removed." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 72 + +rintelligenceModuleInserted TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A redundant intelligence module has been inserted." + --#TYPE "APC UPS: A redundant intelligence module has been inserted." + --#SUMMARY "A redundant intelligence module has been inserted." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 73 + +rintelligenceModuleRemoved TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A redundant intelligence module has been removed." + --#TYPE "APC UPS: A redundant intelligence module has been removed." + --#SUMMARY "A redundant intelligence module has been removed." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 74 + +extBatteryFrameIncease TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An external battery frame has been added." + --#TYPE "APC UPS: An external battery frame has been added." + --#SUMMARY "An external battery frame has been added." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 75 + +extBatteryFrameDecrease TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An external battery frame has been removed." + --#TYPE "APC UPS: An external battery frame has been removed." + --#SUMMARY "An external battery frame has been removed." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 76 + +abnormalCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: An abnormal condition has been detected. + The first variable is the fault condition." + --#TYPE "APC: An abnormal condition has been detected." + --#SUMMARY "An abnormal condition has been detected." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 77 + +abnormalConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An abnormal condition has been cleared. + The first variable is the fault condition." + --#TYPE "APC: An abnormal condition has been cleared." + --#SUMMARY "An abnormal condition has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 78 + +deviceStatusChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString} + DESCRIPTION + "INFORMATIONAL: The status of the device being monitored has changed." + --#TYPE "APC : The status of the device being monitored has changed." + --#SUMMARY "The status of the device being monitored has changed." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 79 + +noBatteries TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The UPS has no batteries attached." + --#TYPE "APC UPS: No batteries attached." + --#SUMMARY "The UPS has no batteries attached." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 80 + +noBatteriesCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The UPS's batteries have been attached." + --#TYPE "APC UPS: The no batteries attached condition has been cleared." + --#SUMMARY "The UPS's batteries have been attached." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 81 + +userAdded TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A new user has been added." + --#TYPE "APC: A new user has been added." + --#SUMMARY "A new user has been added." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 82 + +userDeleted TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A user has been deleted." + --#TYPE "APC: A user has been deleted." + --#SUMMARY "A user has been deleted." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 83 + +userModified TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A user has been modified." + --#TYPE "APC: A user has been modified." + --#SUMMARY "A user has been modified." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 84 + +-- MasterSwitch Vm Traps + +msvmCommunicationEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Communications with the MasterSwitch VM has been established." + --#TYPE "APC: Communications established with the MasterSwitch VM." + --#SUMMARY "Communications with the MasterSwitch VM has been established." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 85 + +msvmCommunicationLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString } + DESCRIPTION + "SEVERE: Communications with the MasterSwitch VM has been lost." + --#TYPE "APC: Communications lost with the MasterSwitch VM." + --#SUMMARY "Communications with the MasterSwitch VM has been lost." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 86 + +msvmOverload TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString } + DESCRIPTION + "SEVERE: The MasterSwitch VM in an overload condition." + --#TYPE "APC: The MasterSwitch VM is near or at an overload condition." + --#SUMMARY "The MasterSwitch VM is near or at an overload condition." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 87 + +msvmOverloadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The overload condition on the MasterSwitch VM has been cleared." + --#TYPE "APC: The overload condition cleared on the MasterSwitch VM." + --#SUMMARY "The overload condition on the MasterSwitch VM has been cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 88 + +msvmOutletOn TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, + sPDUOutletControlVMOutletIndex, sPDUOutletControlVMOutletName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An outlet on the MasterSwitch VM has turned on." + --#TYPE "APC: An outlet on the MasterSwitch VM has turned on." + --#SUMMARY "An outlet on the MasterSwitch VM has turned on." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 89 + +msvmOutletOff TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, + sPDUOutletControlVMOutletIndex, sPDUOutletControlVMOutletName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An outlet on the MasterSwitch VM has turned off." + --#TYPE "APC: An outlet on the MasterSwitch VM has turned off." + --#SUMMARY "An outlet on the MasterSwitch VM has turned off." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 90 + +msvmDeviceConfigChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A device configuration change has been made on a MasterSwitch VM." + --#TYPE "APC: A device configuration change on a MasterSwitch VM." + --#SUMMARY "A device configuration change has been made on a MasterSwitch VM." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 91 + +msvmOutletConfigChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, + sPDUOutletControlVMOutletIndex, sPDUOutletControlVMOutletName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An outlet configuration change has been made on a MasterSwitch VM." + --#TYPE "APC: An outlet configuration change on a MasterSwitch VM." + --#SUMMARY "An outlet configuration change has been made on a MasterSwitch VM." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 92 + +msvmLowLoad TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The MasterSwitch VM has violated the low load threshold." + --#TYPE "APC: The MasterSwitch VM has violated the low load threshold." + --#SUMMARY "The MasterSwitch VM has violated the low load threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 93 + +msvmLowLoadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The low load condition on the MasterSwitch VM has been cleared." + --#TYPE "APC: The low load condition cleared on the MasterSwitch VM." + --#SUMMARY "The low load condition on the MasterSwitch VM has been cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 94 + +msvmNearOverload TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString } + DESCRIPTION + "SEVERE: The MasterSwitch VM is approaching an overload condition." + --#TYPE "APC: The MasterSwitch VM is near or at an overload condition." + --#SUMMARY "The MasterSwitch VM is near or at an overload condition." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 95 + +msvmNearOverloadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The near overload condition on the MasterSwitch VM has been cleared." + --#TYPE "APC: The overload condition cleared on the MasterSwitch VM." + --#SUMMARY "The overload condition on the MasterSwitch VM has been cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 96 + +msvmPowerSupplyStatusChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: The power supply status of the MasterSwitch VM has changed." + --#TYPE "APC: The power supply status changed on MasterSwitch VM" + --#SUMMARY "The power supply status of the MasterSwitch VM has changed." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 97 + +-- MasterSwitch plus (MSP) Traps + +mspCommunicationEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Communications with the MasterSwitch plus has been established." + --#TYPE "APC: Communications established with the MasterSwitch plus." + --#SUMMARY "Communications with the MasterSwitch plus has been established." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 98 + +mspCommunicationLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName, mtrapargsString } + DESCRIPTION + "SEVERE: Communications with the MasterSwitch plus has been lost." + --#TYPE "APC: Communications lost with the MasterSwitch plus." + --#SUMMARY "Communications with the MasterSwitch plus has been lost." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 99 + +mspOutletOn TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName, + sPDUOutletControlMSPOutletIndex, sPDUOutletControlMSPOutletName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An outlet on the MasterSwitch plus has turned on." + --#TYPE "APC: An outlet on the MasterSwitch plus has turned on." + --#SUMMARY "An outlet on the MasterSwitch plus has turned on." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 100 + +mspOutletOff TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName, + sPDUOutletControlMSPOutletIndex, sPDUOutletControlMSPOutletName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An outlet on the MasterSwitch plus has turned off." + --#TYPE "APC: An outlet on the MasterSwitch plus has turned off." + --#SUMMARY "An outlet on the MasterSwitch plus has turned off." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 101 + +mspDeviceConfigChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A device configuration change has been made on a MasterSwitch plus." + --#TYPE "APC: A device configuration change on a MasterSwitch plus." + --#SUMMARY "A device configuration change has been made on a MasterSwitch plus." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 102 + +mspOutletConfigChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName, sPDUOutletControlMSPOutletIndex, sPDUOutletControlMSPOutletName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An outlet configuration change has been made on a MasterSwitch plus." + --#TYPE "APC: An outlet configuration change on a MasterSwitch plus." + --#SUMMARY "An outlet configuration change has been made on a MasterSwitch plus." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 103 + +rsSourceSwitched TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger02, mtrapargsString03, mtrapargsInteger, mtrapargsString02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The Redundant Switch has switched source. + The first variable is an integer representing the current source: 0=A, 1=B. + The second variable is the 32-character name of the current source. + The third variable is an integer representing the transfer cause: + 0=No Transfers Recorded, 1=Due to user action or preferred switching, + 3=Due to line notch or spike, 5=Due to low line voltage, + 7=Transfer due to high line voltage, + 9=Transfer due to frequency out of range. + The fourth variable is a character string listing the transfer cause." + --#TYPE "APC Redundant Switch: The Redundant Switch has switched source" + --#SUMMARY "The Redundant Switch has switched source." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 104 + +rsLostRedundancy TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString02, mtrapargsString } + DESCRIPTION + "SEVERE: The Redundant Switch has lost redundancy. + The first variable is an integer representing the source which is no longer available: 0=A, 1=B. + The second variable is the 32-character name of the source which is no longer available." + --#TYPE "APC Redundant Switch: The Redundant Switch has lost redundancy" + --#SUMMARY "The Redundant Switch has lost redundancy." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 105 + +rsRedundancyRestored TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Redundancy has been restored to the Redundant Switch . + The first variable is an integer representing the source which has been restored: 0=A, 1=B. + The second variable is the 32-character name of the source which has been restored." + --#TYPE "APC Redundant Switch: Redundancy has been restored." + --#SUMMARY "Redundancy has been restored to the Redundant Switch ." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 106 + +rsConfigChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A configuration change has been made on a Redundant Switch." + --#TYPE "APC: A configuration change on a Redundant Switch." + --#SUMMARY "A configuration change has been made on a Redundant Switch." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 107 + +rsCommunicationEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Communications with the Redundant Switch has been established." + --#TYPE "APC: Communications established with the Redundant Switch." + --#SUMMARY "Communications with the Redundant Switch has been established." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 108 + +rsCommunicationLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: Communications with the Redundant Switch has been lost." + --#TYPE "APC: Communications lost with the Redundant Switch." + --#SUMMARY "Communications with the Redundant Switch has been lost." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 109 + +dcCommunicationEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Communications with the DC power plant has been established." + --#TYPE "APC: Communications established with the DC power plant." + --#SUMMARY "Communications with the DC power plant has been established." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 110 + +dcCommunicationLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: Communications with the DC power plant has been lost." + --#TYPE "APC: Communications lost with the DC power plant." + --#SUMMARY "Communications with the DC power plant has been lost." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 111 + +dcPINChanged TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The active PIN on the DC controller has been changed." + --#TYPE "APC: The active PIN on the DC controller has been changed." + --#SUMMARY "The active PIN on the DC controller has been changed." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 112 + +dcMajorAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: A Major alarm is active in the DC power plant." + --#TYPE "APC: A Major alarm is active in the DC power plant." + --#SUMMARY "A Major alarm is active in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 113 + +dcMajorAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Major alarm is no longer active in the DC power plant." + --#TYPE "APC: A Major alarm is no longer active in the DC power plant." + --#SUMMARY "A Major alarm is no longer active in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 114 + +dcMinorAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A Minor alarm is active in the DC power plant." + --#TYPE "APC: A Minor alarm is active in the DC power plant." + --#SUMMARY "A Minor alarm is active in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 115 + +dcMinorAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Minor alarm is no longer active in the DC power plant." + --#TYPE "APC: A Minor alarm is no longer active in the DC power plant." + --#SUMMARY "A Minor alarm is no longer active in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 116 + +dcOutputRelayOn TRAP-TYPE + ENTERPRISE apc + VARIABLES { dm3StatusOutRlyIndex, dm3StatusOutRlyName, mtrapargsString } + DESCRIPTION + "WARNING: An output relay for the powerplant has been activated (state changed to on). + The first variable is an integer representing the output relay number that has gone on. + The second variable is the 16-character name of the output relay." + --#TYPE "APC: An output relay has gone on." + --#SUMMARY "An output relay has gone on in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 117 + +dcOutputRelayOff TRAP-TYPE + ENTERPRISE apc + VARIABLES { dm3StatusOutRlyIndex, dm3StatusOutRlyName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An output relay for the powerplant has been deactivated (state changed to off). + The first variable is an integer representing the output relay number that has gone off. + The second variable is the 16-character name of the output relay." + --#TYPE "APC: An output relay has gone off." + --#SUMMARY "An output relay has gone off in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 118 + +dcInputRelayOn TRAP-TYPE + ENTERPRISE apc + VARIABLES { dm3StatusInRlyIndex, dm3StatusInRlyName, mtrapargsString } + DESCRIPTION + "WARNING: An input relay for the powerplant has been activated (state changed to on). + The first variable is an integer representing the input relay number that has gone on. + The second variable is the 16-character name of the input relay." + --#TYPE "APC: An input relay has gone on." + --#SUMMARY "An input relay has gone on in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 119 + +dcInputRelayOff TRAP-TYPE + ENTERPRISE apc + VARIABLES { dm3StatusInRlyIndex, dm3StatusInRlyName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An input relay for the powerplant has been deactivated (state changed to off). + The first variable is an integer representing the input relay number that has gone off. + The second variable is the 16-character name of the input relay." + --#TYPE "APC: An input relay has gone off." + --#SUMMARY "An input relay has gone off in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 120 + +logicPowerSuppliesIncreased TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The number of system power supplies has increased." + --#TYPE "APC UPS: The number of system power supplies has increased." + --#SUMMARY "The number of system power supplies has increased." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 121 + +logicPowerSuppliesDecreased TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The number of system power supplies has decreased." + --#TYPE "APC UPS: The number of system power supplies has decreased." + --#SUMMARY "The number of system power supplies has decreased." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 122 + +externalSwitchGearClosed TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: External Switch Gear closed." + --#TYPE "APC UPS: External Switch Gear closed." + --#SUMMARY "External Switch Gear closed." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 123 + +externalSwitchGearOpened TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: External Switch Gear opened." + --#TYPE "APC UPS: External Switch Gear opened." + --#SUMMARY "External Switch Gear opened." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 124 + +generalDeviceEvent TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: APC Device event." + --#TYPE "APC Device event" + --#SUMMARY "APC Device event." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 125 + +atsSourceSwitched TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The Automatic Transfer Switch has switched source. + The first variable is an integer representing the current source: 0=A, 1=B. + The second variable is the 32-character name of the current source." + --#TYPE "APC Automatic Transfer Switch: The ATS has switched source" + --#SUMMARY "The Automatic Transfer Switch has switched source." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 126 + +atsLostRedundancy TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString02, mtrapargsString } + DESCRIPTION + "SEVERE: The Automatic Transfer Switch has lost redundancy. + The first variable is an integer representing the source which is no longer available: 0=A, 1=B. + The second variable is the 32-character name of the source which is no longer available." + --#TYPE "APC Automatic Transfer Switch: The ATS has lost redundancy. " + --#SUMMARY "The Automatic Transfer Switch has lost redundancy." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 127 + +atsRedundancyRestored TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Redundancy has been restored to the Automatic Transfer Switch . + The first variable is an integer representing the source which has been restored: 0=A, 1=B. + The second variable is the 32-character name of the source which has been restored." + --#TYPE "APC Automatic Transfer Switch: Redundancy has been restored." + --#SUMMARY "Redundancy has been restored to the Automatic Transfer Switch ." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 128 + +atsConfigChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A configuration change has been made on the Automatic Transfer Switch. + The first variable is an integer representing the configuration setting which changed: + 0=Transfer Voltage Range, 1=Sensitivity, 2=Preferred Source + 3=Front Panel Lockout, 4=Current Limit, 5=Reset XA Processor, + 6=Reset to defaults, 7=Product Name, 8=Nominal Voltage, 9=Nominal Line Frequency, + 10=Narrow VRMS, 11=Medium VRMS, 12=Wide VRMS,13=Frequency Deviation, + 14=ColdStart ATS, 15=Events Count Cleared, 16=Phase or Bank Threshold. " + --#TYPE "APC Automatic Transfer Switch: ATS configuration changed." + --#SUMMARY "A configuration change has been made on a Automatic Transfer Switch." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 129 + +atsCommunicationEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Communications with the Automatic Transfer Switch has been established." + --#TYPE "APC Automatic Transfer Switch: Communications established." + --#SUMMARY "Communications with the Automatic Transfer Switch has been established." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 130 + +atsCommunicationLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: Communications with the Automatic Transfer Switch has been lost." + --#TYPE "APC Automatic Transfer Switch: Communications lost." + --#SUMMARY "Communications with the Automatic Transfer Switch has been lost." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 131 + +atsOverCurrent TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: Output Current has exceeded threshold. This is same as atsOverload Trap + for phase or total in case banked units" + + --#TYPE "APC Automatic Transfer Switch: Output Current exceeded threshold" + --#SUMMARY "Output Current has exceeded Threshold. " + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 132 + +atsOverCurrentCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Output Current has returned below threshold.This is same as atsOverloadCleared Trap + for phase or total in case banked units" + --#TYPE "APC Automatic Transfer Switch: Output Current below threshold." + --#SUMMARY "Output Current has returned below threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 133 + +atsPowerSupplyFailure TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The Automatic Transfer Switch Power Supply has failed. + The first variable is an integer representing the Power Supply which + has failed: 0 = Source A 24V, + 1 = 12V, + 2 = 5V, + 3 = Source B 24V." + --#TYPE "APC Automatic Transfer Switch: The ATS Power Supply has failed." + --#SUMMARY "The Automatic Transfer Switch Power Supply has failed." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 134 + +atsPowerSupplyFailureCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The Automatic Transfer Power Supply Failure Cleared. + The first variable is an integer representing the Power Supply which + has cleared: 0 = Source A 24V, + 1 = 12V, + 2 = 5V, + 3 = Source B 24V." + --#TYPE "APC Automatic Transfer Switch: Power Supply Failure Cleared." + --#SUMMARY "The Automatic Transfer Switch Power Supply Failure Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 135 + +dcMainsFailAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A Mains Fail alarm is active in the DC power plant." + --#TYPE "APC: A Mains Fail alarm is active in the DC power plant." + --#SUMMARY "A Mains Fail alarm is active in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 136 + +dcMainsFailAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Mains Fail alarm is no longer active in the DC power plant." + --#TYPE "APC: Mains Fail alarm is no longer active in the DC power plant." + --#SUMMARY "Mains Fail alarm is no longer active in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 137 + +dcFanFailAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A Fan Fail alarm is active in the DC power plant." + --#TYPE "APC: A Fan Fail alarm is active in the DC power plant." + --#SUMMARY "A Fan Fail alarm is active in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 138 + +dcFanFailAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Fan Fail alarm is no longer active in the DC power plant." + --#TYPE "APC: A Fan Fail alarm is no longer active in the DC power plant." + --#SUMMARY "A Fan Fail alarm is no longer active in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 139 + +dcRectifierOvertempAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: Rect. Overtemp alarm is active in the power plant." + --#TYPE "APC: Rect. Overtemp alarm is active in the power plant." + --#SUMMARY "Rect. Overtemp alarm is active in the power plant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 140 + +dcRectifierOvertempAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Rect. Overtemp alarm is no longer active in the power plant." + --#TYPE "APC: Rect. Overtmp alarm is no longer active in the power plant." + --#SUMMARY "Rect. Overtemp alarm is no longer active in the power plant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 141 + +dcCurrentLimitAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A Current Limit alarm is active in the power plant." + --#TYPE "APC: A Current Limit alarm is active in the power plant." + --#SUMMARY "A Current Limit alarm is active in the power plant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 142 + +dcCurrentLimitAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Current Limit alarm is no longer active in the power plant." + --#TYPE "APC: Current Limit alarm is no longer active in the power plant." + --#SUMMARY "Current Limit alarm is no longer active in the power plant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 143 + +dcRectifierFailAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A Rect. Fail alarm is active in the power plant." + --#TYPE "APC: A Rect. Fail alarm is active in the power plant." + --#SUMMARY "A Rect. Fail alarm is active in the power plant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 144 + +dcRectifierFailAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Rect. Fail alarm is no longer active in the power plant." + --#TYPE "APC: Rect. Fail alarm is no longer active in the power plant." + --#SUMMARY "Rect. Fail alarm is no longer active in the power plant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 145 + +dcMultRectFailAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: Multiple Rect. Fail alarm is active in the powerplant." + --#TYPE "APC: Multiple Rect. Fail alarm is active in the powerplant." + --#SUMMARY "Multiple Rect. Fail alarm is active in the powerplant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 146 + +dcMultRectFailAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Multiple Rect Fail alarm is no longer active in the powerplant." + --#TYPE "APC: Multiple Rect Fail alarm is no longer active in powerplant." + --#SUMMARY "Multiple Rect Fail alarm is no longer active in the powerplant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 147 + +dcBatteryBreakerAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: Batt. Breaker alarm is active in the power plant." + --#TYPE "APC: Batt. Breaker alarm is active in the power plant." + --#SUMMARY "Batt. Breaker alarm is active in the power plant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 148 + +dcBatteryBreakerAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Batt. Breaker alarm is no longer active in the power plant." + --#TYPE "APC: Batt. Breaker alarm is no longer active in the power plant." + --#SUMMARY "Batt. Breaker alarm is no longer active in the power plant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 149 + +dcRectifierOVPAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A Rect. OVP alarm is active in the power plant." + --#TYPE "APC: A Rect. OVP alarm is active in the power plant." + --#SUMMARY "A Rect. OVP alarm is active in the power plant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 150 + +dcRectifierOVPAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Rect. OVP alarm is no longer active in the power plant." + --#TYPE "APC: A Rect. OVP alarm is no longer active in the power plant." + --#SUMMARY "A Rect. OVP alarm is no longer active in the power plant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 151 + +dcLVDImminentAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A LVD Imminent alarm is active in the powerplant." + --#TYPE "APC: A LVD Imminent alarm is active in the powerplant." + --#SUMMARY "A LVD Imminent alarm is active in the powerplant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 152 + +dcLVDImminentAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A LVD Imminent alarm is no longer active in the powerplant." + --#TYPE "APC: A LVD Imminent alarm is no longer active in the powerplant." + --#SUMMARY "A LVD Imminent alarm is no longer active in the powerplant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 153 + +dcFuseCBAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A Fuse/CB alarm is active in the DC power plant." + --#TYPE "APC: A Fuse/CB alarm is active in the DC power plant." + --#SUMMARY "A Fuse/CB alarm is active in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 154 + +dcFuseCBAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Fuse/CB alarm is no longer active in the DC power plant." + --#TYPE "APC: A Fuse/CB alarm is no longer active in the DC power plant." + --#SUMMARY "A Fuse/CB alarm is no longer active in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 155 + +dcBatteryTestFail TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A Battery Test failed in the DC power plant." + --#TYPE "APC: A Battery Test failed in the DC power plant." + --#SUMMARY "A Battery Test failed in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 156 + +dcTemperatureAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A Temperature is active in the power plant." + --#TYPE "APC: A Temperature alarm is active in the power plant." + --#SUMMARY "A Temperature alarm is active in the power plant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 157 + +dcTemperatureAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Temperature alarm is no longer active in the power plant." + --#TYPE "APC: A Temperature alarm is no longer active in the power plant." + --#SUMMARY "A Temperature alarm is no longer active in the power plant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 158 + +dcHumidityAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A Humidity alarm is active in the DC power plant." + --#TYPE "APC: A Humidity alarm is active in the DC power plant." + --#SUMMARY "A Humidity alarm is active in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 159 + +dcHumidityAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Humidity alarm is no longer active in the DC power plant." + --#TYPE "APC: A Humidity alarm is no longer active in the DC power plant." + --#SUMMARY "A Humidity alarm is no longer active in the DC power plant." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 160 + +dcBBCommunicationEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Power plant bridging board communications established." + --#TYPE "APC: Power plant bridging board communications established." + --#SUMMARY "Power plant bridging board communications established." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 161 + +dcBBCommunicationLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: Power plant bridging board communications lost." + --#TYPE "APC: Power plant bridging board communications lost." + --#SUMMARY "Power plant bridging board communications lost." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 162 + +iemHighTempThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { iemStatusProbeCurrentTemp, iemStatusProbeTempUnits, iemStatusProbeNumber, + iemStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: High temperature threshold violated on Integrated + Environmental Monitor probe. The first variable is the + current temperature. The second variable is the temperature + scale. The third variable is the probe number. The fourth + variable is the probe name." + --#TYPE "APC IEM: High temperature threshold violation." + --#SUMMARY "High temperature threshold violation." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 163 + +iemHighTempThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { iemStatusProbeNumber, iemStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: High temperature threshold violated on Integrated + Environmental Monitor probe has been cleared. The first variable + is the probe number. The second variable is the probe name." + --#TYPE "APC IEM: High temperature threshold violation cleared." + --#SUMMARY "High temperature threshold violation has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 164 + +iemLowTempThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { iemStatusProbeCurrentTemp, iemStatusProbeTempUnits, iemStatusProbeNumber, + iemStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: Low temperature threshold violated on integrated + probe. The first variable is the current temperature. The + second variable is the temperature scale. The third + variable is the probe number. The fourth variable is the + probe name." + --#TYPE "APC IEM: Low temperature threshold violation." + --#SUMMARY "Low temperature threshold violation." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 165 + +iemLowTempThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { iemStatusProbeNumber, iemStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Low temperature threshold violated on integrated + probe has been cleared. The first variable is the probe number. + The second variable is the probe name." + --#TYPE "APC IEM: Low temperature threshold violation cleared." + --#SUMMARY "Low temperature threshold violation has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 166 + +iemHighHumidThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { iemStatusProbeCurrentHumid, iemStatusProbeNumber, iemStatusProbeName, + mtrapargsString } + DESCRIPTION + "SEVERE: High humidity threshold violated on integrated + probe. The first variable is the current humidity. The + second variable is the probe number. The third variable + is the probe name." + --#TYPE "APC IEM: High humidity threshold violation." + --#SUMMARY "High humidity threshold violation." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 167 + +iemHighHumidThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { iemStatusProbeNumber, iemStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: High humidity threshold violated on integrated + probe cleared. The first variable is the probe number. The second + variable is the probe name." + --#TYPE "APC IEM: High humidity threshold violation cleared." + --#SUMMARY "High humidity threshold violation has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 168 + +iemLowHumidThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { iemStatusProbeCurrentHumid, iemStatusProbeNumber, iemStatusProbeName, + mtrapargsString } + DESCRIPTION + "SEVERE: Low humidity threshold violated on integrated + probe. The first variable is the current humidity. The + second variable is the probe number. The third variable + is the probe name." + --#TYPE "APC IEM: Low humidity threshold violation." + --#SUMMARY "Low humidity threshold violation." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 169 + +iemLowHumidThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { iemStatusProbeNumber, iemStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Low humidity threshold violated on integrated + probe cleared. The first variable is the probe number. The second + variable is the probe name." + --#TYPE "APC IEM: Low humidity threshold violation cleared." + --#SUMMARY "Low humidity threshold violation has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 170 + +iemProbeDisconnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The temperature/humidity probe on the Integrated + Environmental Monitor has been disconnected. This trap is + generated when a probe that has been in communication with + the Environmental Monitor has been disconnected or can no + longer communicate." + --#TYPE "APC IEM: Probe disconnected." + --#SUMMARY "Probe has been disconnected." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 171 + +iemProbeConnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The temperature/humidity probe on the Integrated + Environmental Monitor has been connected. This trap is generated + when the Environmental Monitor establishes communication with a + probe that had previously not been connected." + --#TYPE "APC IEM: Probe Connected." + --#SUMMARY "Probe has been connected." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 172 + +iemContactFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { iemStatusContactNumber, iemStatusContactName, mtrapargsString } + DESCRIPTION + "SEVERE: There is a contact fault on the Integrated + Environmental Monitor. The first argument is the number + of the contact. The second argument is the name of the + contact." + --#TYPE "APC IEM: Contact fault." + --#SUMMARY "Contact fault." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 173 + +iemContactFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { iemStatusContactNumber, iemStatusContactName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The contact fault on the Integrated + Environmental Monitor has been cleared. The first + argument is the number of the contact. The second + argument is the name of the contact." + --#TYPE "APC IEM: Contact fault." + --#SUMMARY "Contact fault cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 174 + +iemRelayFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { iemStatusRelayNumber, iemStatusRelayName, mtrapargsString02, mtrapargsString } + DESCRIPTION + "SEVERE: The output relay on the Integrated Environmental + Monitor has switched to the fault state. The first + argument is the number of the output relay. The second + argument is the name of the output relay. The third + argument is the event that caused the fault." + --#TYPE "APC IEM: Output relay fault." + --#SUMMARY "Output relay has faulted." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 175 + +iemRelayFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { iemStatusRelayNumber, iemStatusRelayName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The fault condition on the output relay on the + Integrated Environmental Monitor has cleared. The first + argument is the number of the output relay. The second + argument is the name of the output relay." + --#TYPE "APC IEM: Output relay fault condition cleared." + --#SUMMARY "Output relay fault cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 176 + +bmBatManCommEstab TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Serial Communications Established with Battery Manager." + --#TYPE "BatMan : Communications Established." + --#SUMMARY "Communications Established." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 177 + +bmBatManCommLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Serial Communications Lost with Battery Manager." + --#TYPE "BatMan : Communications Lost." + --#SUMMARY "Communications Lost." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 178 + +bmBatManKneeAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Battery Voltage Knee Threshold Alarm Detected." + --#TYPE "BatMan : Knee Alarm Detected." + --#SUMMARY "Knee Alarm Detected." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 179 + +bmBatManKneeAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Battery Voltage Knee Threshold Alarm Cleared." + --#TYPE "BatMan : Knee Alarm Cleared." + --#SUMMARY "Knee Alarm Cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 180 + +bmBatManChargerAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: Charger Alarm Detected." + --#TYPE "BatMan : Charger Alarm Detected." + --#SUMMARY "Charger Alarm Detected." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 181 + +bmBatManChargerAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Charger Alarm Cleared." + --#TYPE "BatMan : Charger Alarm Cleared." + --#SUMMARY "Charger Alarm Cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 182 + +bmBatManBatteryAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: Battery Alarm Detected." + --#TYPE "BatMan : Battery Alarm Detected." + --#SUMMARY "Battery Alarm Detected." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 183 + +bmBatManBatteryAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Battery Alarm Cleared." + --#TYPE "BatMan : Battery Alarm Cleared." + --#SUMMARY "Battery Alarm Cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 184 + +bmBatManEnvironmentAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: Environment Alarm Detected." + --#TYPE "BatMan : Environment Alarm Detected." + --#SUMMARY "Environment Alarm Detected." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 185 + +bmBatManEnvironmentAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Environment Alarm Cleared." + --#TYPE "BatMan : Environment Alarm Cleared." + --#SUMMARY "Environment Alarm Cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 186 + +bmBatManMaintenanceAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Maintenance Alarm Detected." + --#TYPE "BatMan : Maintenance Due Alarm Detected." + --#SUMMARY "Maintenance Due Alarm Detected." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 187 + +bmBatManMaintenanceAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Maintenance Alarm Cleared." + --#TYPE "BatMan : Maintenance Due Alarm Cleared." + --#SUMMARY "Maintenance Due Alarm Cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 188 + +pduCommunicationEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Communication Established. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: Communication Established." + --#SUMMARY "Communication Established." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 189 + +pduCommunicationLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "SEVERE: Communication Lost. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: Communication Lost." + --#SUMMARY "Communication Lost." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 190 + +pduUtilityLineUndervoltage TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Utility Line Undervoltage. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC PDU: Utility Line Undervoltage." + --#SUMMARY "Utility Line Undervoltage." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 191 + +pduUtilityLineUndervoltageCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Utility Line Undervoltage Cleared. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC PDU: Utility Line Undervoltage Cleared." + --#SUMMARY "Utility Line Undervoltage Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 192 + +pduUtilityLineOvervoltage TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Utility Line Overvoltage. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC PDU: Utility Line Overvoltage." + --#SUMMARY "Utility Line Overvoltage." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 193 + +pduUtilityLineOvervoltageCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Utility Line Overvoltage Cleared. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC PDU: Utility Line Overvoltage Cleared." + --#SUMMARY "Utility Line Overvoltage Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 194 + +pduGroundOvercurrent TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "SEVERE: Ground Overcurrent. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: Ground Overcurrent." + --#SUMMARY "Ground Overcurrent." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 195 + +pduGroundOvercurrentCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Ground Overcurrent Cleared. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: Ground Overcurrent Cleared." + --#SUMMARY "Ground Overcurrent Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 196 + +pduCircuitPanelInputUndervoltage TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Circuit Panel Input Undervoltage. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC PDU: Circuit Panel Input Undervoltage." + --#SUMMARY "Circuit Panel Input Undervoltage." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 197 + +pduCircuitPanelInputUndervoltageCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Circuit Panel Input Undervoltage Cleared. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC PDU: Circuit Panel Input Undervoltage Cleared." + --#SUMMARY "Circuit Panel Input Undervoltage Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 198 + +pduCircuitPanelInputOvervoltage TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Circuit Panel Input Overvoltage. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC PDU: Circuit Panel Input Overvoltage." + --#SUMMARY "Circuit Panel Input Overvoltage." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 199 + +pduCircuitPanelInputOvervoltageCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Circuit Panel Input Overvoltage Cleared. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC PDU: Circuit Panel Input Overvoltage Cleared." + --#SUMMARY "Circuit Panel Input Overvoltage Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 200 + +pduCircuitPanelInputUndercurrent TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Circuit Panel Input Undercurrent. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC PDU: Circuit Panel Input Undercurrent." + --#SUMMARY "Circuit Panel Input Undercurrent." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 201 + +pduCircuitPanelInputUndercurrentCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Circuit Panel Input Undercurrent Cleared. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC PDU: Circuit Panel Input Undercurrent Cleared." + --#SUMMARY "Circuit Panel Input Undercurrent Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 202 + +pduCircuitPanelInputOvercurrent TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Circuit Panel Input Overcurrent. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC PDU: Circuit Panel Input Overcurrent." + --#SUMMARY "Circuit Panel Input Overcurrent." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 203 + +pduCircuitPanelInputOvercurrentCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Circuit Panel Input Overcurrent Cleared. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC PDU: Circuit Panel Input Overcurrent Cleared." + --#SUMMARY "Circuit Panel Input Overcurrent Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 204 + +pduCircuitPanelFrequencyOutOfRange TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "SEVERE: Circuit Panel Input Frequency Out Of Range. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: Circuit Panel Input Frequency Out Of Range." + --#SUMMARY "Circuit Panel Input Frequency Out Of Range." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 205 + +pduCircuitPanelFrequencyOutofRangeCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Circuit Panel Input Frequency No Longer Out Of Range. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: Circuit Panel Input Frequency No Longer Out Of Range." + --#SUMMARY "Circuit Panel Input Frequency No Longer Out Of Range." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 206 + +pduCircuitPanelNeutralOvercurrent TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "SEVERE: Circuit Panel Input Neutral Overcurrent. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: Circuit Panel Input Neutral Overcurrent." + --#SUMMARY "Circuit Panel Input Neutral Overcurrent." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 207 + +pduCircuitPanelNeutralOvercurrentCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Circuit Panel Input Neutral Overcurrent Cleared. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: Circuit Panel Input Neutral Overcurrent Cleared." + --#SUMMARY "Circuit Panel Input Neutral Overcurrent Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 208 + +pduSystemOff TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "SEVERE: PDU System Off. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: System Off." + --#SUMMARY "PDU System Off." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 209 + +pduOnBatteryMode TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "SEVERE: PDU is in On Battery Mode. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: On Battery Mode." + --#SUMMARY "PDU is in On Battery Mode." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 210 + +pduMaintenanceBypassMode TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: PDU is in Maintenance Bypass Mode. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: Maintenance Bypass Mode." + --#SUMMARY "PDU is in Maintenance Bypass Mode." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 211 + +pduAtypicalBypassMode TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "WARNING: PDU is in Atypical Bypass Mode. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: Atypical Bypass Mode." + --#SUMMARY "PDU is in Atypical Bypass Mode." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 212 + +pduNoPanelFeedMode TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "SEVERE: PDU is in No Panel Feed Mode. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: No Panel Feed Mode." + --#SUMMARY "PDU is in No Panel Feed Mode." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 213 + +pduUpsOperationMode TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: PDU is in Ups Operation Mode. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: Ups Operation Mode." + --#SUMMARY "PDU is in Ups Operation Mode." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 214 + +pduForcedBypassMode TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "WARNING: PDU is in Forced Bypass Mode. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: Forced Bypass Mode." + --#SUMMARY "PDU is in Forced Bypass Mode." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 215 + +pduInputTransformerOverTemperature TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "SEVERE: Input Transformer Over Temperature. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: Input Transformer Over Temperature." + --#SUMMARY "Input Transformer Over Temperature." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 216 + +pduInputTransformerOverTemperatureCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Input Transformer Over Temperature Cleared. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC PDU: Input Transformer Over Temperature Cleared." + --#SUMMARY "Input Transformer Over Temperature Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 217 + +pduUPSInputVoltageLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: UPS Input Voltage phase-N Lost. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC PDU: UPS Input Voltage phase-N Lost." + --#SUMMARY "UPS Input Voltage phase-N Lost." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 218 + +pduUPSInputVoltageRestored TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: UPS Input Voltage phase-N Restored. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC PDU: UPS Input Voltage phase-N Restored." + --#SUMMARY "UPS Input Voltage phase-N Restored." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 219 + +pduContactFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: A contact closure in the PDU is in an abnormal position. + The first argument is the serial number. + The second argument is the device name. + The third argument is the number of the contact." + --#TYPE "APC PDU: Contact Abnormal." + --#SUMMARY "Contact Abnormal." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 220 + +pduContactFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A contact closure in the PDU is in a normal position. + The first argument is the serial number. + The second argument is the device name. + The third argument is the number of the contact." + --#TYPE "APC PDU: Contact Normal." + --#SUMMARY "Contact Normal." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 221 + +rPDUBankPhaseLowLoad TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString } + DESCRIPTION + "WARNING: A bank or phase on the Rack PDU has violated the low load threshold. + The first argument is the serial number. + The second argument is the device name. + The third argument is the bank number (0 if this is phase data). + The fourth argument is the phase number (0 if this is bank data)." + --#TYPE "APC Rack PDU: Violation of bank or phase low load threshold." + --#SUMMARY "A bank or phase on the Rack PDU has violated the low load threshold." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 222 + +rPDUBankPhaseLowLoadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The bank or phase low load condition on a Rack PDU has been + cleared. + The first argument is the serial number. + The second argument is the device name. + The third argument is the bank number (0 if this is phase data). + The fourth argument is the phase number (0 if this is bank data)." + --#TYPE "APC Rack PDU: Bank or phase low load condition cleared." + --#SUMMARY "The bank or phase low load condition on a Rack PDU has been cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 223 + +rPDUBankPhaseNearOverload TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString } + DESCRIPTION + "WARNING: A bank or phase of the Rack PDU is near an overload condition. + The first argument is the serial number. + The second argument is the device name. + The third argument is the bank number (0 if this is phase data). + The fourth argument is the phase number (0 if this is bank data)." + --#TYPE "APC Rack PDU: Bank or phase near an overload condition." + --#SUMMARY "A bank or phase of the Rack PDU is near an overload condition." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 224 + +rPDUBankPhaseNearOverloadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The bank or phase near overload condition on a Rack PDU has + been cleared. + The first argument is the serial number. + The second argument is the device name. + The third argument is the bank number (0 if this is phase data). + The fourth argument is the phase number (0 if this is bank data)." + --#TYPE "APC Rack PDU: Bank or phase near overload condition has cleared." + --#SUMMARY "Rack PDU bank or phase near overload condition has cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 225 + +rPDUBankPhaseOverload TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString } + DESCRIPTION + "SEVERE: A bank or phase of the Rack PDU is in an overload condition. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number. + The third argument is the bank number (0 if this is phase data). + The fourth argument is the phase number (0 if this is bank data)." + --#TYPE "APC Rack PDU: Bank or phase overload condition." + --#SUMMARY "A bank or phase of the Rack PDU is in an overload condition." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 226 + +rPDUBankPhaseOverloadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The bank or phase overload condition on a Rack PDU has been + cleared. + The first argument is the serial number. + The second argument is the device name. + The third argument is the bank number (0 if this is phase data). + The fourth argument is the phase number (0 if this is bank data)." + --#TYPE "APC Rack PDU: Bank or phase overload condition has cleared." + --#SUMMARY "The bank or phase overload condition on a Rack PDU has cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 227 + +aruDeviceConfigChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Remote ARU Device Configuration change. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name." + --#TYPE "APC ARU: ARU Device configuration change." + --#SUMMARY "ARU device configuration change." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 228 + +rmPDUCommunicationLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString } + DESCRIPTION + "SEVERE: Communication Lost. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC RM PDU: Communication Lost." + --#SUMMARY "Communication Lost." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 229 + +emsCommunicationEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Communication Established. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC EMS: Communication Established." + --#SUMMARY "Communication Established." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 230 + +emsCommunicationLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString } + DESCRIPTION + "SEVERE: Communication Lost. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC EMS: Communication Lost." + --#SUMMARY "Communication Lost." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 231 + +emsProbeConnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A probe has been connected to the EMS. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the probe number. + The fourth argument is the probe name." + --#TYPE "APC EMS: Probe Connected." + --#SUMMARY "Probe Connected." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 232 + +emsProbeDisconnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: A probe has been disconnected from the EMS. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the probe number. + The fourth argument is the probe name." + --#TYPE "APC EMS: Probe Disconnected." + --#SUMMARY "Probe Disconnected." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 233 + +emsSensorConnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + emsSensorStatusSensorIndex, emsSensorStatusSensorName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A sensor has been connected to the EMS. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the sensor number. + The fourth argument is the sensor name." + --#TYPE "APC EMS: Sensor Connected." + --#SUMMARY "Sensor Connected." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 234 + +emsSensorDisconnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + emsSensorStatusSensorIndex, emsSensorStatusSensorName, mtrapargsString } + DESCRIPTION + "SEVERE: A sensor has been disconnected from the EMS. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the sensor number. + The fourth argument is the sensor name." + --#TYPE "APC EMS: Sensor Disconnected." + --#SUMMARY "Sensor Disconnected." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 235 + +emsSensorFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + emsSensorStatusSensorIndex, emsSensorStatusSensorName, mtrapargsString } + DESCRIPTION + "SEVERE: A EMS sensor is in the fault condition. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the sensor number. + The fourth argument is the sensor name." + --#TYPE "APC EMS: Sensor Fault." + --#SUMMARY "Sensor Fault." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 236 + +emsSensorFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + emsSensorStatusSensorIndex, emsSensorStatusSensorName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A EMS sensor fault condition has cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the sensor number. + The fourth argument is the sensor name." + --#TYPE "APC EMS: Sensor Fault Cleared." + --#SUMMARY "Sensor Fault Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 237 + +emsBeaconConnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A beacon has been connected to the EMS. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC EMS: Beacon Connected." + --#SUMMARY "Beacon Connected." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 238 + +emsBeaconDisconnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString } + DESCRIPTION + "SEVERE: A beacon has been disconnected from the EMS. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC EMS: Beacon Disconnected." + --#SUMMARY "Beacon Disconnected." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 239 + +emsBeaconOn TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A EMS beacon has gone on. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC EMS: Beacon On." + --#SUMMARY "Beacon On." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 240 + +emsBeaconOff TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A EMS beacon has gone off. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC EMS: Beacon Off." + --#SUMMARY "Beacon Off." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 241 + +emsMajorAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString } + DESCRIPTION + "SEVERE: A Major Alarm is present in the EMS. + The first argument is the EMS serial number. + The second argument is the EMS name." + --#TYPE "APC EMS: Major Alarm." + --#SUMMARY "Major Alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 242 + +emsMajorAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Major Alarm condition has been cleared in the EMS. + The first argument is the EMS serial number. + The second argument is the EMS name." + --#TYPE "APC EMS: Major Alarm Cleared." + --#SUMMARY "Major Alarm Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 243 + +emsMinorAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString } + DESCRIPTION + "SEVERE: A Minor Alarm is present in the EMS. + The first argument is the EMS serial number. + The second argument is the EMS name." + --#TYPE "APC EMS: Minor Alarm." + --#SUMMARY "Minor Alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 244 + +emsMinorAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Minor Alarm condition has been cleared in the EMS. + The first argument is the EMS serial number. + The second argument is the EMS name." + --#TYPE "APC EMS: Minor Alarm Cleared." + --#SUMMARY "Minor Alarm Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 245 + +emsOutletStateAbnormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsOutletStatusOutletIndex, emsOutletStatusOutletName, + emsOutletStatusOutletState, emsOutletStatusOutletNormalState, mtrapargsString } + DESCRIPTION + "WARNING: An outlet on the EMS has changed to its abnormal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the outlet number. + The fourth argument is the outlet name. + The fifth argument is the current outlet state (1=ON, 2=OFF). + The sixth argument is the configured normal outlet state (1=ON, 2=OFF)." + --#TYPE "APC EMS: Outlet has changed to its abnormal state." + --#SUMMARY "Outlet has changed to its abnormal state." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 246 + +emsOutletStateNormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsOutletStatusOutletIndex, emsOutletStatusOutletName, + emsOutletStatusOutletState, emsOutletStatusOutletNormalState, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An outlet on the EMS has changed to its normal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the outlet number. + The fourth argument is the outlet name. + The fifth argument is the current outlet state (1=ON, 2=OFF). + The sixth argument is the configured normal outlet state (1=ON, 2=OFF)." + --#TYPE "APC EMS: Outlet has changed to its normal state." + --#SUMMARY "Outlet has changed to its normal state." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 247 + +emsInputContactStateAbnormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsInputContactStatusInputContactIndex, + emsInputContactStatusInputContactName, emsInputContactStatusInputContactState, + emsInputContactStatusInputContactNormalState, mtrapargsString } + DESCRIPTION + "WARNING: An input contact on the EMS has changed to its abnormal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the input contact number. + The fourth argument is the input contact name. + The fifth argument is the input contact state (1=CLOSED, 2=OPEN). + The sixth argument is the configured normal input contact state (1=CLOSED, 2=OPEN)." + --#TYPE "APC EMS: Input contact has changed to its abnormal state." + --#SUMMARY "Input contact has changed to its abnormal state." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 248 + +emsInputContactStateNormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsInputContactStatusInputContactIndex, + emsInputContactStatusInputContactName, emsInputContactStatusInputContactState, + emsInputContactStatusInputContactNormalState, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An input contact on the EMS has changed to its normal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the input contact number. + The fourth argument is the input contact name. + The fifth argument is the input contact state (1=CLOSED, 2=OPEN). + The sixth argument is the configured normal input contact state (1=CLOSED, 2=OPEN)." + --#TYPE "APC EMS: Input contact has changed to its normal state." + --#SUMMARY "Input contact has changed to its normal state." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 249 + +emsOutputRelayStateAbnormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsOutputRelayStatusOutputRelayIndex, + emsOutputRelayStatusOutputRelayName, emsOutputRelayStatusOutputRelayState, + emsOutputRelayStatusOutputRelayNormalState, mtrapargsString } + DESCRIPTION + "WARNING: An output relay on the EMS has changed to its abnormal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the output relay number. + The fourth argument is the output relay name. + The fifth argument is the current output relay state (1=CLOSED, 2=OPEN). + The sixth argument is the configured normal output relay state (1=CLOSED, 2=OPEN)." + --#TYPE "APC EMS: Output Relay has changed to its abnormal state." + --#SUMMARY "Output Relay has changed to its abnormal state." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 250 + +emsOutputRelayStateNormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsOutputRelayStatusOutputRelayIndex, + emsOutputRelayStatusOutputRelayName, emsOutputRelayStatusOutputRelayState, + emsOutputRelayStatusOutputRelayNormalState, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An output relay on the EMS has changed to its normal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the output relay number. + The fourth argument is the output relay name. + The fifth argument is the current output relay state (1=CLOSED, 2=OPEN). + The sixth argument is the configured normal output relay state (1=CLOSED, 2=OPEN)." + --#TYPE "APC EMS: Output Relay has changed to its normal state." + --#SUMMARY "Output Relay has changed to its normal state." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 251 + +emsDeviceConfigChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A device configuration change has been made on the EMS. + The first argument is the EMS serial number. + The second argument is the EMS name." + --#TYPE "APC: A device configuration change on a EMS." + --#SUMMARY "A device configuration change has been made on a EMS." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 252 + +envHighTempThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: High temperature threshold violated on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: High temperature threshold violation." + --#SUMMARY "High temperature threshold violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 253 + +envHighTempThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: High temperature threshold violation cleared on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: High temperature threshold violation cleared." + --#SUMMARY "High temperature threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 254 + +envLowTempThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: Low temperature threshold violated on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: Low temperature threshold violation." + --#SUMMARY "Low temperature threshold violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 255 + +envLowTempThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Low temperature threshold violation cleared on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: Low temperature threshold violation cleared." + --#SUMMARY "Low temperature threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 256 + +envHighHumidityThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: High humidity threshold violated on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current humidity + The fourth argument is the probe number. + The fifth argument is the probe name." + --#TYPE "APC ENV: High humidity threshold violation." + --#SUMMARY "High humidity threshold violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 257 + +envHighHumidityThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: High humidity threshold violation cleared on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current humidity. + The fourth argument is the probe number. + The fifth argument is the probe name." + --#TYPE "APC ENV: High humidity threshold violation cleared." + --#SUMMARY "High humidity threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 258 + +envLowHumidityThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: Low humidity threshold violated on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current humidity + The fourth argument is the probe number. + The fifth argument is the probe name." + --#TYPE "APC ENV: Low humidity threshold violation." + --#SUMMARY "Low humidity threshold violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 259 + +envLowHumidityThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Low humidity threshold violation cleared on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current humidity. + The fourth argument is the probe number. + The fifth argument is the probe name." + --#TYPE "APC ENV: Low humidity threshold violation cleared." + --#SUMMARY "Low humidity threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 260 + + +-- Switched and Metered Rack PDU Traps + +rPDUCommunicationEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Communication with a Rack PDU has been established. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC Rack PDU: Communication established." + --#SUMMARY "Communication with a Rack PDU established." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 266 + +rPDUCommunicationLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString } + DESCRIPTION + "SEVERE: Communication with a Rack PDU has been lost. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC Rack PDU: Communication lost." + --#SUMMARY "Communication with a Rack PDU has been lost." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 267 + +rPDUOutletOn TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDUOutletControlIndex, rPDUOutletControlOutletName, + mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An outlet on a Switched Rack PDU has turned on. + The first argument is the serial number. + The second argument is the device name. + The third argument is the outlet index number. + The fourth argument is the outlet name." + --#TYPE "APC Switched Rack PDU: An outlet has turned on." + --#SUMMARY "An outlet on a Switched Rack PDU has turned on." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 268 + +rPDUOutletOff TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDUOutletControlIndex, rPDUOutletControlOutletName, + mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An outlet on a Switched Rack PDU has turned off. + The first argument is the serial number. + The second argument is the device name. + The third argument is the outlet index number. + The fourth argument is the outlet name." + --#TYPE "APC Switched Rack PDU: An outlet has turned off." + --#SUMMARY "An outlet on a Switched Rack PDU has turned off." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 269 + +rPDUDeviceConfigChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A device configuration change has been made on a + Rack PDU. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC Rack PDU: Device configuration change made." + --#SUMMARY "Device configuration change has been made on a Rack PDU." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 270 + +rPDUOutletConfigChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDUOutletControlIndex, rPDUOutletControlOutletName, + mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An outlet configuration change has been made on a + Switched Rack PDU. + The first argument is the serial number. + The second argument is the device name. + The third argument is the outlet index number. + The fourth argument is the outlet name." + --#TYPE "APC Switched Rack PDU: Outlet configuration change made." + --#SUMMARY "Outlet configuration change has been made on a Switched Rack PDU." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 271 + +rPDULowLoad TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDULoadStatusPhaseNumber, mtrapargsString } + DESCRIPTION + "WARNING: A Rack PDU has violated the low load threshold. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC Rack PDU: Violation of low load threshold." + --#SUMMARY "A Rack PDU has violated the low load threshold." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 272 + +rPDULowLoadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDULoadStatusPhaseNumber, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The low load condition on a Rack PDU has been + cleared. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC Rack PDU: Low load condition cleared." + --#SUMMARY "The low load condition on a Rack PDU has been cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 273 + +rPDUNearOverload TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDULoadStatusPhaseNumber, mtrapargsString } + DESCRIPTION + "WARNING: A Rack PDU is near an overload condition. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC Rack PDU: Near an overload condition." + --#SUMMARY "A Rack PDU is near an overload condition." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 274 + +rPDUNearOverloadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDULoadStatusPhaseNumber, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The near overload condition on a Rack PDU has + been cleared. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC Rack PDU: Near overload condition has cleared." + --#SUMMARY "Rack PDU near overload condition has cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 275 + +rPDUOverload TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDULoadStatusPhaseNumber, mtrapargsString } + DESCRIPTION + "SEVERE: A Rack PDU is in an overload condition. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC Rack PDU: Overload condition." + --#SUMMARY "A Rack PDU is in an overload condition." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 276 + +rPDUOverloadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDULoadStatusPhaseNumber, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The overload condition on a Rack PDU has been + cleared. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase number." + --#TYPE "APC Rack PDU: Overload condition has cleared." + --#SUMMARY "The overload condition on a Rack PDU has cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 277 + +rPDUPowerSupply1Fail TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString } + DESCRIPTION + "SEVERE: Power Supply 1 on Rack PDU is in FAIL state. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC Rack PDU: Power Supply 1 is in FAIL state." + --#SUMMARY "Power Supply 1 on Rack PDU is in FAIL state." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 278 + +rPDUPowerSupply1Ok TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Power Supply 1 on Rack PDU is operating normally. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC Rack PDU: Power Supply 1 is operating normally." + --#SUMMARY "Power Supply 1 on Rack PDU is operating normally." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 279 + +rPDUPowerSupply2Fail TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString } + DESCRIPTION + "SEVERE: Power Supply 2 on Rack PDU is in FAIL state. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC Rack PDU: Power Supply 2 is in FAIL state." + --#SUMMARY "Power Supply 2 on Rack PDU is in FAIL state." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 280 + +rPDUPowerSupply2Ok TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Power Supply 2 on Rack PDU is operating normally. + The first argument is the serial number. + The second argument is the device name." + --#TYPE "APC Rack PDU: Power Supply 2 is operating normally." + --#SUMMARY "Power Supply 2 on Rack PDU is operating normally." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 281 + +rPDUPhaseConfigChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDULoadPhaseConfigIndex, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A phase configuration change has been made on a + Rack PDU. + The first argument is the serial number. + The second argument is the device name. + The third argument is the phase index number." + --#TYPE "APC Rack PDU: Phase configuration change made." + --#SUMMARY "Phase configuration change has been made on a Rack PDU." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 282 + +rPDUCancelPendingCommand TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDUOutletControlIndex, rPDUOutletControlOutletName, + mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A cancel pending command has been made on a + Switched Rack PDU. + The first argument is the serial number. + The second argument is the device name. + The third argument is the outlet index number (0 indicates all outlets). + The fourth argument is the outlet name (or device name if all outlets)." + --#TYPE "APC Switched Rack PDU: Cancel Pending Command made." + --#SUMMARY "A Cancel Pending Command has been made on a Switched Rack PDU." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 283 + +aruAlinkCommunicationEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Remote ARU Communication Established. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name." + --#TYPE "APC ARU: Communication Established." + --#SUMMARY "Communication Established." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 284 + +aruAlinkCommunicationLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsString } + DESCRIPTION + "SEVERE: Remote ARU Communication Lost. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name." + --#TYPE "APC ARU: Communication Lost." + --#SUMMARY "Communication Lost." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 285 + +aruFanFail TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsString } + DESCRIPTION + "SEVERE: Remote ARU Fan Fail. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name." + --#TYPE "APC ARU: Fan Failure." + --#SUMMARY "Fan Fail." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 286 + +aruFanFailCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Remote ARU Fan Fail Cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name." + --#TYPE "APC ARU: Fan Fail Cleared." + --#SUMMARY "Fan Fail Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 287 + +aruSmokeAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsString } + DESCRIPTION + "SEVERE: Remote ARU Smoke Alarm. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name." + --#TYPE "APC ARU: Smoke Alarm." + --#SUMMARY "Smoke Alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 288 + +aruSmokeAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Remote ARU Smoke Alarm Cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name." + --#TYPE "APC ARU: Smoke Alarm Cleared." + --#SUMMARY "Smoke Alarm Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 289 + +aruHighTemperatureAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsString } + DESCRIPTION + "WARNING: ARU Exhaust temperature has exceeded the override + threshold and the ARU has increased fan speed to + maintain a safe environment in the rack. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name." + --#TYPE "APC ARU: High Temperature Alarm." + --#SUMMARY "High Temperature Alarm." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 290 + +aruHighTemperatureAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: ARU temperature override state has been cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name." + --#TYPE "APC ARU: High Temperature Alarm Cleared." + --#SUMMARY "High Temperature Alarm Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 291 + +aruExhaustTemperatureAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsString } + DESCRIPTION + "SEVERE: ARU Extreme Exhaust Temperature Alarm. + The ARU is unable to control the temperature within the rack + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name." + --#TYPE "APC ARU: Exhaust Temperature Alarm." + --#SUMMARY "Exhaust Temperature Alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 292 + +aruExhaustTemperatureAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Remote ARU Exhaust Temperature Alarm Cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name." + --#TYPE "APC ARU: Exhaust Temperature Alarm Cleared." + --#SUMMARY "Exhaust Temperature Alarm Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 293 + +envAlinkCommunicationEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Remote Probe Communication Established. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the probe number. + The fourth argument is the probe name." + --#TYPE "APC ENV: Communication Established." + --#SUMMARY "Communication Established." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 294 + +envAlinkCommunicationLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: Remote Probe Communication Lost. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the probe number. + The fourth argument is the probe name." + --#TYPE "APC ENV: Communication Lost." + --#SUMMARY "Communication Lost." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 295 + +emsAlinkPowerOverload TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString } + DESCRIPTION + "SEVERE: Alink Power Overload. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC EMS: Alink Power Overload." + --#SUMMARY "Alink Power Overload." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 296 + +emsAlinkPowerOverloadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Alink Power Overload Cleared. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC EMS: Alink Power Overload Cleared." + --#SUMMARY "Alink Power Overload Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 297 + +upsOutletGroupTurnedOn TRAP-TYPE + ENTERPRISE apc + VARIABLES { upsOutletGroupControlIndex, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The specified Outlet Group turned on." + --#TYPE "APC UPS: Outlet Group turned on." + --#SUMMARY "Outlet Group turned on" + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 298 + +upsOutletGroupTurnedOff TRAP-TYPE + ENTERPRISE apc + VARIABLES { upsOutletGroupControlIndex, mtrapargsString } + DESCRIPTION + "WARNING: The specified Outlet Group turned off." + --#TYPE "APC UPS: Outlet Group turned off." + --#SUMMARY "Outlet Group turned off." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 299 + +smwCriticalCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsGauge, mtrapargsString } + DESCRIPTION + "SEVERE: A Symmetra MW UPS critical condition has been detected. + The first variable is the fault condition." + --#TYPE "APC Symmetra MW UPS: A critical condition has been detected." + --#SUMMARY "A critical condition has been detected." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 300 + +smwCriticalConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsGauge, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Symmetra MW UPS critical condition has been cleared. + The first variable is the fault condition." + --#TYPE "APC Symmetra MW UPS: A critical condition has been cleared." + --#SUMMARY "A critical condition has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 301 + +smwWarningCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsGauge, mtrapargsString } + DESCRIPTION + "WARNING: A Symmetra MW UPS warning condition has been detected. + The first variable is the fault condition." + --#TYPE "APC Symmetra MW UPS: A warning condition has been detected." + --#SUMMARY "A warning condition has been detected." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 302 + +smwWarningConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsGauge, mtrapargsString } + DESCRIPTION + "WARNING: A Symmetra MW UPS warning condition has been cleared. + The first variable is the fault condition." + --#TYPE "APC Symmetra MW UPS: A warning condition has been cleared." + --#SUMMARY "A warning condition has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 303 + +smwInformationalCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsGauge, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Symmetra MW UPS informational condition has been detected. + The first variable is the fault condition." + --#TYPE "APC Symmetra MW UPS: Informational condition detected." + --#SUMMARY "An informational condition has been detected." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 304 + +smwInformationalConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsGauge, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Symmetra MW UPS informational condition has been cleared. + The first variable is the fault condition." + --#TYPE "APC Symmetra MW UPS: Informational condition cleared." + --#SUMMARY "An informational condition has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 305 + +airCriticalCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: An Air critical condition was detected. + The first variable is the error condition text message. + The second variable is the error number." + --#TYPE "APC Air: A critical condition was detected. " + --#SUMMARY "A critical condition was detected. " + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 306 + +airCriticalConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An Air critical condition was cleared. + The first variable is the error condition text message. + The second variable is the error number." + --#TYPE "APC Air: A critical condition was cleared. " + --#SUMMARY "A critical condition was cleared. " + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 307 + +airWarningCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: An Air warning condition was detected. + The first variable is the error condition text message. + The second variable is the error number." + --#TYPE "APC Air: A warning condition was detected. " + --#SUMMARY "A warning condition was detected. " + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 308 + +airWarningConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: An Air warning condition was cleared. + The first variable is the error condition text message. + The second variable is the error number." + --#TYPE "APC Air: A warning condition was cleared. " + --#SUMMARY "A warning condition was cleared. " + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 309 + +airInformationalCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An Air informational condition was detected. + The first variable is the error condition text message. + The second variable is the error number." + --#TYPE "APC Air: Informational condition detected. " + --#SUMMARY "An informational condition was detected. " + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 310 + +airInformationalConditionCleared TRAP-TYPE + ENTERPRISE apc + + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An Air informational condition was cleared. + The first variable is the error condition text message. + The second variable is the error number." + --#TYPE "APC Air: Informational condition was cleared. " + --#SUMMARY "An informational condition was cleared. " + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 311 + +-- xPDU Traps (part 1) + +xPDUInputVoltageLowAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: Three-phase input voltage to the device is outside the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). + The fourth argument is the measured voltage in tenths of Volts. + The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated." + --#TYPE "APC XPDU: Main input low voltage alarm." + --#SUMMARY "Input voltage is below threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 312 + +xPDUInputVoltageLowAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Three-phase input voltage to the device is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). + The fourth argument is the measured voltage in tenths of Volts." + --#TYPE "APC XPDU: Main input low voltage alarm cleared." + --#SUMMARY "Main input low voltage cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 313 + + +xPDUInputVoltageHighAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: Three-phase input voltage to the device is outside the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). + The fourth argument is the measured voltage in tenths of Volts. + The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated." + --#TYPE "APC XPDU: Main input high voltage alarm." + --#SUMMARY "Main input voltage is above threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 314 + +xPDUInputVoltageHighAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Three-phase input voltage to the device is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). + The fourth argument is the measured voltage in tenths of Volts." + --#TYPE "APC XPDU: Main input high voltage alarm cleared." + --#SUMMARY "Main input high voltage alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 315 + +xPDUBypassVoltageLowAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: Three-phase bypass input voltage to the device is outside the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). + The fourth argument is the measured voltage in tenths of Volts. + The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated." + --#TYPE "APC XPDU: Bypass input low voltage alarm." + --#SUMMARY "Bypass input voltage is below threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 316 + +xPDUBypassVoltageLowAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Three-phase bypass input voltage to the device is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). + The fourth argument is the measured voltage in tenths of Volts." + --#TYPE "APC XPDU: Bypass input low voltage alarm cleared." + --#SUMMARY "Bypass input low voltage alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 317 + +xPDUBypassVoltageHighAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: Three-phase bypass input voltage to the device is outside the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). + The fourth argument is the measured voltage in tenths of Volts. + The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated." + --#TYPE "APC XPDU: Bypass input high voltage alarm." + --#SUMMARY "Bypass input voltage is above threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 318 + +xPDUBypassVoltageHighAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Three-phase bypass input voltage to the device is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). + The fourth argument is the measured voltage in tenths of Volts." + --#TYPE "APC XPDU: Bypass input high voltage alarm cleared." + --#SUMMARY "Bypass input voltage alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 319 + +xPDUOutputVoltageLowAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: The three-phase output voltage of the device is outside the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). + The fourth argument is the measured voltage in tenths of Volts. + The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated." + --#TYPE "APC XPDU: Output low voltage alarm." + --#SUMMARY "Output voltage is below threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 320 + +xPDUOutputVoltageLowAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The three-phase output voltage of the device is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). + The fourth argument is the measured voltage in tenths of Volts." + --#TYPE "APC XPDU: Output low voltage alarm cleared." + --#SUMMARY "Output low voltage alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 321 + +xPDUOutputVoltageHighAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: The three-phase output voltage of the device is outside the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). + The fourth argument is the measured voltage in tenths of Volts. + The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated." + --#TYPE "APC XPDU: Output high voltage alarm." + --#SUMMARY "Output voltage is above threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 322 + +xPDUOutputVoltageHighAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The three-phase output voltage of the device is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). + The fourth argument is the measured voltage in tenths of Volts." + --#TYPE "APC XPDU: Output high voltage alarm cleared." + --#SUMMARY "Output high voltage alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 323 + +xPDUOutputCurrentLowAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: The three-phase output load current of the device is outside the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1, 2=L2, 3=L3). + The fourth argument is the measured current in tenths of Amps. + The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated." + --#TYPE "APC XPDU: Output low current alarm." + --#SUMMARY "Output current is below threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 324 + +xPDUOutputCurrentLowAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The three-phase output load current of the device is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1, 2=L2, 3=L3). + The fourth argument is the measured current in tenths of Amps." + --#TYPE "APC XPDU: Output low current alarm cleared." + --#SUMMARY "Output low current alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 325 + +xPDUOutputCurrentHighAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: The three-phase load current of the device is outside the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1, 2=L2, 3=L3). + The fourth argument is the measured current in tenths of Amps. + The fifth argument is the threshold, in tenths of Amps, above which the alarm was generated." + --#TYPE "APC XPDU: Output high current alarm." + --#SUMMARY "Output current is above threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 326 + +xPDUOutputCurrentHighAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The three-phase output current of the device is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1, 2=L2, 3=L3). + The fourth argument is the measured current in tenths of Amps." + --#TYPE "APC XPDU: Output high current alarm cleared." + --#SUMMARY "Output high current alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 327 + +xPDUOutputFrequencyAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The devices output frequency is outside the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the frequency deviation from the nominal in tenths of Hertz." + --#TYPE "APC XPDU: Output frequency out-of-range alarm." + --#SUMMARY "Output frequency is out-of-range." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 328 + +xPDUOutputFrequencyAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The devices output frequency is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XPDU: Output frequency back in range." + --#SUMMARY "Output frequency in range." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 329 + +xPDUSystemGroundCurrentAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "SEVERE: The earth ground current of the device is over the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the measured current in tenths of Amps. + The fourth argument is the threshold, in tenths of Amps, above which the alarm was generated." + --#TYPE "APC XPDU: Earth ground high current alarm." + --#SUMMARY "Earth ground current is above threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 330 + +xPDUSystemGroundCurrentAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The earth ground current of the device is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the measured current in tenths of Amps." + --#TYPE "APC XPDU: Earth ground high current alarm cleared." + --#SUMMARY "Earth ground high current alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 331 + +xPDUInputContactStateAbnormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsString02, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: A user input contact on the device has changed to its abnormal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the input contact number. + The fourth argument is the input contact name. + The fifth argument is the input contact state (1=OPEN, 2=CLOSED). + The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED)." + --#TYPE "APC XPDU: Input contact has changed to its abnormal state." + --#SUMMARY "Input contact has changed to its abnormal state." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 332 + +xPDUInputContactStateNormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsString02, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A user input contact on the device has changed to its normal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the input contact number. + The fourth argument is the input contact name. + The fifth argument is the input contact state (1=CLOSED, 2=OPEN). + The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED)." + --#TYPE "APC XPDU: Input contact has changed to its normal state." + --#SUMMARY "Input contact has changed to its normal state." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 333 + +xPDUOutputNeutralCurrentHighAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "WARNING: The three-phase neutral current of the device is outside the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the measured current in tenths of Amps. + The fourth argument is the threshold, in tenths of Amps, above which the alarm was generated." + --#TYPE "APC XPDU: Output high neutral current alarm." + --#SUMMARY "Output neutral current is above threshold." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 334 + +xPDUOutputNeutralCurrentHighAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The output neutral current of the device is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the measured current in tenths of Amps." + --#TYPE "APC XPDU: Output neutral high current alarm cleared." + --#SUMMARY "Output neutral high current alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 335 + +xPDUCoolingFanAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString } + DESCRIPTION + "SEVERE: The device's internal cooling fans have failed. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XPDU: Cooling fan failure alarm." + --#SUMMARY "Cooling fan failure." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 336 + +xPDUCoolingFanAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The device's cooling fans are now functioning properly. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XPDU: Cooling fan alarm cleared." + --#SUMMARY "Cooling fan alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 337 + +xPDUTransformerTempAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString } + DESCRIPTION + "SEVERE: The device's isolation transformer is over temperature. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XPDU: Isolation transformer over temperature alarm." + --#SUMMARY "Transformer temp alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 338 + +xPDUTransformerTempAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The device's isolation transformer is no longer over temperature. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XPDU: Isolation transformer over temperature alarm cleared." + --#SUMMARY "Transformer temp alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 339 + +xPDUBranchCurrentLowAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "WARNING: The current in a branch circuit is outside the limits specified for that + branch circuit. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the panel position of the branch circuit (1-based index). + The fourth argument is the measured current in tenths of Amps. + The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated." + --#TYPE "APC XPDU: Branch circuit low current alarm." + --#SUMMARY "Branch circuit current is below threshold." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 340 + +xPDUBranchCurrentLowAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The current in a branch circuit is back within the limits + specified for that branch circuit. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the panel position of the branch circuit (1-based index). + The fourth argument is the measured current in tenths of Amps." + --#TYPE "APC XPDU: Branch circuit low current alarm cleared." + --#SUMMARY "Branch circuit low current alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 341 + +xPDUBranchCurrentHighAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "WARNING: The current in a branch circuit is outside the limits specified for that + branch circuit. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the panel position of the branch circuit (1-based index). + The fourth argument is the measured current in tenths of Amps. + The fifth argument is the threshold, in tenths of Amps, above which the alarm was generated." + --#TYPE "APC XPDU: Branch circuit high current alarm." + --#SUMMARY "Branch circuit current is above threshold." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 342 + +xPDUBranchCurrentHighAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The current in a branch circuit is back within the limits + specified for that branch circuit. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the panel position of the branch circuit (1-based index). + The fourth argument is the measured current in tenths of Amps." + --#TYPE "APC XPDU: Branch circuit high current alarm cleared." + --#SUMMARY "Branch circuit high current alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 343 + + +xPDUInternalCommError TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString } + DESCRIPTION + "SEVERE: There is an internal communication error in the device. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XPDU: Internal communication error." + --#SUMMARY "Internal communication error." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 344 + +emsHardwareStateAbnormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString } + DESCRIPTION + "SEVERE: The device's hardware is improperly configured and operating outside + normal bounds for the hardware. This can be caused by improper devices being + connected to the EMS ports or Alink Current limit detection." + --#TYPE "APC EMS: Hardware is in an abnormal state." + --#SUMMARY "Hardware is in an abnormal state." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 345 + +emsHardwareStateNormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The device's hardware is in its normal operational state. + The first argument is the host device serial number." + --#TYPE "APC EMS: Hardware is in a normal state." + --#SUMMARY "Hardware is in its normal state." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 346 + +ceSevereCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: A Custom Event severe condition was detected. + The first variable is the custom event text message. + The second variable is the custom event number." + --#TYPE "APC Custom Event: A severe condition was detected. " + --#SUMMARY "A severe condition was detected. " + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 347 + +ceSevereConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Custom Event severe condition was cleared. + The first variable is the custom event text message. + The second variable is the custom event number." + --#TYPE "APC Custom Event: A severe condition was cleared. " + --#SUMMARY "A severe condition was cleared. " + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 348 + +ceWarningCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: A Custom Event warning condition was detected. + The first variable is the custom event text message. + The second variable is the custom event number." + --#TYPE "APC Custom Event: A warning condition was detected. " + --#SUMMARY "A warning condition was detected. " + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 349 + +ceWarningConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Custom Event warning condition was cleared. + The first variable is the custom event text message. + The second variable is the custom event number." + --#TYPE "APC Custom Event: A warning condition was cleared. " + --#SUMMARY "A warning condition was cleared. " + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 350 + +ceInformationalCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Custom Event informational condition was detected. + The first variable is the custom event text message. + The second variable is the custom event number." + --#TYPE "APC Custom Event: Informational condition detected. " + --#SUMMARY "An informational condition was detected. " + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 351 + +ceInformationalConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Custom Event informational condition was cleared. + The first variable is the custom event text message. + The second variable is the custom event number." + --#TYPE "APC Custom Event: Informational condition was cleared. " + --#SUMMARY "An informational condition was cleared. " + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 352 + +upsInternalOverTemperature TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The internal over temperature condition exists." + --#TYPE "APC UPS: The internal over temperature condition exists." + --#SUMMARY "The internal over temperature condition exists." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 353 + +upsInternalOverTemperatureCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The internal over temperature condition cleared." + --#TYPE "APC UPS: The internal over temperature condition cleared." + --#SUMMARY "The internal over temperature condition cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 354 + +upsMpuReset TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The MPU has been reset." + --#TYPE "APC UPS: The MPU has been reset." + --#SUMMARY "The MPU has been reset." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 355 + +upsOutputSwitchClosed TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The Output Switch is closed." + --#TYPE "APC UPS: The Output Switch is closed." + --#SUMMARY "The Output Switch is closed." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 356 + +upsOutputSwitchOpened TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The Output Switch is open." + --#TYPE "APC UPS: The Output Switch is open." + --#SUMMARY "The Output Switch is open." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 357 + +upsCalibrationStackChanged TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A calibration value in the stack was changed." + --#TYPE "APC UPS: A calibration value in the stack was changed." + --#SUMMARY "A calibration value in the stack was changed." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 358 + + +-- Upgraded EMS now has more env traps + +envMaxTempThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: Max temperature threshold violated on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: Max temperature threshold violation." + --#SUMMARY "Max temperature threshold violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 359 + +envMaxTempThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Max temperature threshold violation cleared on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: Max temperature threshold violation cleared." + --#SUMMARY "Max temperature threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 360 + +envMinTempThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: Min temperature threshold violated on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: Min temperature threshold violation." + --#SUMMARY "Min temperature threshold violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 361 + +envMinTempThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Min temperature threshold violation cleared on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: Min temperature threshold violation cleared." + --#SUMMARY "Min temperature threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 362 + +envMaxHumidityThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: Max humidity threshold violated on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current humidity + The fourth argument is the probe number. + The fifth argument is the probe name." + --#TYPE "APC ENV: Max humidity threshold violation." + --#SUMMARY "Max humidity threshold violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 363 + +envMaxHumidityThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Max humidity threshold violation cleared on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current humidity. + The fourth argument is the probe number. + The fifth argument is the probe name." + --#TYPE "APC ENV: Max humidity threshold violation cleared." + --#SUMMARY "Max humidity threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 364 + +envMinHumidityThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: Min humidity threshold violated on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current humidity + The fourth argument is the probe number. + The fifth argument is the probe name." + --#TYPE "APC ENV: Min humidity threshold violation." + --#SUMMARY "Min humidity threshold violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 365 + +envMinHumidityThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Min humidity threshold violation cleared on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current humidity. + The fourth argument is the probe number. + The fifth argument is the probe name." + --#TYPE "APC ENV: Min humidity threshold violation cleared." + --#SUMMARY "Min humidity threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 366 + +envSTIncTempRateViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: Short-term increasing temperature rate violated on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: Short-term inc. temp rate violation." + --#SUMMARY "Short-term inc. temp rate violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 367 + +envSTIncTempRateViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Short-term increasing temperature rate cleared on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: Short-term inc. temp rate violation cleared." + --#SUMMARY "Short-term inc. temp rate violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 368 + +envSTDecTempRateViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: Short-term decreasing temperature rate violated on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: Short-term dec. temp rate violation." + --#SUMMARY "Short-term dec. temp rate violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 369 + +envSTDecTempRateViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Short-term decreasing temperature rate cleared on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: Short-term dec. temp rate violation cleared." + --#SUMMARY "Short-term dec. temp rate violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 370 + +envLTIncTempRateViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: Long-term increasing temperature rate violated on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: Long-term inc. temp rate violation." + --#SUMMARY "Long-term inc. temp rate violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 371 + +envLTIncTempRateViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Long-term increasing temperature rate cleared on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: Long-term inc. temp rate violation cleared." + --#SUMMARY "Long-term inc. temp rate violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 372 + +envLTDecTempRateViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "SEVERE: Long-term decreasing temperature rate violated on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: Long-term dec. temp rate violation." + --#SUMMARY "Long-term dec. temp rate violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 373 + +envLTDecTempRateViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits, + emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Long-term decreasing temperature rate cleared on the probe. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the current temperature. + The fourth argument is the temperature scale. + The fifth argument is the probe number. + The sixth argument is the probe name." + --#TYPE "APC ENV: Long-term dec. temp rate violation cleared." + --#SUMMARY "Long-term dec. temp rate violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 374 + +-- Battery Management System Traps + +bmsCriticalCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: A Battery Management System critical condition was detected. + The first variable is the error condition text message. + The second variable is the error number." + --#TYPE "APC BMS: A critical condition was detected. " + --#SUMMARY "A critical condition was detected. " + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 375 + +bmsCriticalConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Battery Management System critical condition was cleared. + The first variable is the error condition text message. + The second variable is the error number." + --#TYPE "APC BMS: A critical condition was cleared. " + --#SUMMARY "A critical condition was cleared. " + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 376 + +bmsWarningCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: A Battery Management System warning condition was detected. + The first variable is the error condition text message. + The second variable is the error number." + --#TYPE "APC BMS: A warning condition was detected. " + --#SUMMARY "A warning condition was detected. " + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 377 + +bmsWarningConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: A Battery Management System warning condition was cleared. + The first variable is the error condition text message. + The second variable is the error number." + --#TYPE "APC BMS: A warning condition was cleared. " + --#SUMMARY "A warning condition was cleared. " + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 378 + +bmsInformationalCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Battery Management System informational condition was detected. + The first variable is the error condition text message. + The second variable is the error number." + --#TYPE "APC BMS: Informational condition detected. " + --#SUMMARY "An informational condition was detected. " + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 379 + +bmsInformationalConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A Battery Management System informational condition was cleared. + The first variable is the error condition text message. + The second variable is the error number." + --#TYPE "APC BMS: Informational condition was cleared. " + --#SUMMARY "An informational condition was cleared. " + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 380 + +-- xATS Traps + +xATSOutputVoltageLowAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: The device three-phase output voltage of the device is outside the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). + The fourth argument is the measured voltage in tenths of Volts. + The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated." + --#TYPE "APC XATS: Output low voltage alarm." + --#SUMMARY "Output voltage is below threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 381 + +xATSOutputVoltageLowAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The devices three-phase output voltage is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). + The fourth argument is the measured voltage in tenths of Volts." + --#TYPE "APC XATS: Output low voltage alarm cleared." + --#SUMMARY "Output low voltage alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 382 + +xATSOutputVoltageHighAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: The device three-phase output voltage of the device is outside the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). + The fourth argument is the measured voltage in tenths of Volts. + The fifth argument is the threshold, in tenths of Volts, above which the alarm is generated." + --#TYPE "APC XATS: Output high voltage alarm." + --#SUMMARY "Output voltage is above threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 383 + +xATSOutputVoltageHighAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The devices three-phase output voltage is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). + The fourth argument is the measured voltage in tenths of Volts." + --#TYPE "APC XATS: Output high voltage alarm cleared." + --#SUMMARY "Output high voltage alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 384 + +xATSOutputCurrentLowAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: The three-phase load current of the device is outside the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1, 2=L2, 3=L3). + The fourth argument is the measured current in Amps. + The fifth argument is the threshold, in Amps, from which the alarm was generated." + --#TYPE "APC XATS: Output low current alarm." + --#SUMMARY "Output current is below threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 385 + +xATSOutputCurrentLowAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The three-phase load current of the device is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1, 2=L2, 3=L3). + The fourth argument is the measured current in Amps." + --#TYPE "APC XATS: Output low current alarm cleared." + --#SUMMARY "Output low current alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 386 + +xATSOutputCurrentHighAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: The three-phase output load current of the device is outside the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1, 2=L2, 3=L3). + The fourth argument is the measured current in Amps. + The fifth argument is the threshold, in Amps, from which the alarm was generated." + --#TYPE "APC XATS: Output high current alarm." + --#SUMMARY "Output current is above threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 387 + +xATSOutputCurrentHighAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The three-phase output load current of the device is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1, 2=L2, 3=L3). + The fourth argument is the measured current in Amps." + --#TYPE "APC XATS: Output high current alarm cleared." + --#SUMMARY "Output high current alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 388 + + +xATSOutputFrequencyAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "SEVERE: The devices output frequency is outside the specified limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the frequency deviation from the nominal in tenths of Hertz. + The fourth argument is the frequency deviation threshold in tenths of Hertz, + from which the alarm was generated." + --#TYPE "APC XATS: Output frequency out-of-range alarm." + --#SUMMARY "Output frequency is out-of-range." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 389 + +xATSOutputFrequencyAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The devices output frequency is back within the specified limits. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Output frequency back in range." + --#SUMMARY "Output frequency in range." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 390 + +xATSInternalCommError TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "SEVERE: There is an internal communication error in the device. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Internal communication error." + --#SUMMARY "Internal communication error." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 391 + +xATSInternalCommErrorCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Internal communication has been restored. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Internal Communication error cleared." + --#SUMMARY "ATS Communication error cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 392 + +xATSDataCommMismatchError TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "SEVERE: A data incompatibility exists within the device. This + is typically the result of mismatches between firmware revisions + of the transfer switch controller and the Network Management interface. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Data mismatch error." + --#SUMMARY "ATS data mismatch error." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 393 + +xATSDataCommMismatchErrorCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The internal data incompatibility has been resolved. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: data mismatch error cleared." + --#SUMMARY "ATS data mismatch error cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 394 + +xATSGenCommLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "WARNING: The XATS cannot communicate with the generator. + This will make unavailable all the xATSGenerator OIDs. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: No communication with generator." + --#SUMMARY "ATS/Generator communication lost." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 395 + +xATSGenCommEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The XATS has established communication with the generator. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Communication with generator established." + --#SUMMARY "ATS/generator communication established." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 396 + +xATSNeutralPosition TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, + mtrapargsString } + DESCRIPTION + "WARNING: XATS has transferred to neutral position. + In this position neither Source 1 nor Source 2 is selected, + and the XATS will have no output voltage. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the mode in which the switch is operating + (1=Auto, 2=Not-in-Auto, Abnormal Condition 3=Not-in-Auto, manual)." + --#TYPE "APC XATS: Transferred to the neutral (no output power) position." + --#SUMMARY "Transferred to neutral." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 397 + +xATSSwitchTransferEvent TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: XATS has transferred from one source to the other. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the mode in which the switch is operating. + (1=Auto, 2=Not-in-Auto, Abnormal Condition 3=Not-in-Auto, manual). + The fourth argument is the input source selected (1=Source 1, 2=Source 2). + The fifth argument is type of transfer that took place. (1=Closed, 2=Open, 3=Unknown)" + --#TYPE "APC XATS: Transferred from Source-X to Source-Y." + --#SUMMARY "Source-to-Source transfer." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 398 + +xATSInternalATSFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: An internal XATS fault has been detected. + The XATS may have forced itself to not-in-auto mode (abnormal condition), + as indicated by the xATSSwitchStatusAutoSwitchOperationalMode OID. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument indicates the detected fault. + + 1=Cannot Close S1 + 2=Cannot Close S2 + 3=Cannot Open S1 + 4=Cannot Open S2 + 5=Cannot Trip Open S1 + 6=Cannot Trip Open S2 + 7=Start Contact Failure + 8=Voltage Sensing Failure" + + --#TYPE "APC XATS: Internal fault detected." + --#SUMMARY "ATS internal fault detected." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 399 + +xATSInternalATSFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The detected internal XATS fault has been cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument indicates the detected fault. + + 1=Cannot Close S1 + 2=Cannot Close S2 + 3=Cannot Open S1 + 4=Cannot Open S2 + 5=Cannot Trip Open S1 + 6=Cannot Trip Open S2 + 7=Start Contact Failure + 8=Voltage Sensing Failure" + + --#TYPE "APC XATS: Internal fault cleared." + --#SUMMARY "ATS internal fault cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 400 + +xATSEngineStartAsserted TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The XATS has asserted the Engine Start contact. + This should result in the generator producing output voltage. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument indicates the reason that the start signal was asserted + 1=Unknown, 2=S1 Low Voltage, 3=S1 High Voltage, 4=S1 Line Imbalance, + 5=S1 Freq Range, 6=S1 Bad Rotation." + --#TYPE "APC XATS: Engine Start signal asserted." + --#SUMMARY "Engine Start asserted." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 401 + +xATSEngineStopAsserted TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The XATS has de-asserted the Engine Start contact. + This should result in the generator shutting down, and producing no output voltage. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Engine Stop signal asserted." + --#SUMMARY "Engine Stop asserted." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 402 + +xATSStartFailure TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The generator failed to start. After assertion of the + Engine Start signal, the quality of Source 2 was not seen as good. + This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument indicates the line quality at S2 + 1=Unknown, 2=S2 Low Voltage, 3=S2 High Voltage, 4=S2 Line Imbalance, + 4=S2 Freq Range, 5=S2 Bad Rotation." + --#TYPE "APC XATS: Generator failed to start alarm." + --#SUMMARY "Generator failed to start." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 403 + +xATSStopFailure TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "WARNING: The generator failed to stop. After de-assertion of the + Engine Start signal, the quality of Source 2 continued to be seen as good. + This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Generator failed to stop alarm." + --#SUMMARY "Generator failed to stop." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 404 + +xATSNotInAutomaticMode TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "SEVERE: Automatic Transfer Switch is not in automatic mode. + The first argument is the host device serial number. + The second argument is the host device name. + The xATSSwitchStatusAutoSwitchStatus OID and the + xATSSwitchStatusAutoSwitchOperationalMode OID + can provide more information about the state of the XATS." + --#TYPE "APC XATS: XATS is not-in-automatic mode." + --#SUMMARY "ATS not in auto." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 405 + +xATSNotInAutomaticModeCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Automatic Transfer Switch is in automatic mode. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: XATS in auto mode." + --#SUMMARY "ATS in auto mode." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 406 + +xATSEpoTripped TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "SEVERE: The device's Emergency Power Off (EPO) circuit is tripped. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Emergency Power Off (EPO) tripped." + --#SUMMARY "EPO tripped." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 407 + +xATSEpoReset TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been + reset to the armed position. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Emergency Power Off (EPO) reset." + --#SUMMARY "EPO armed." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 408 + +xATSEpoTestMode TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "WARNING: The device's Emergency Power Off (EPO) circuit has been + switched back to the test position. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Emergency Power Off (EPO) in test mode." + --#SUMMARY "EPO disabled." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 409 + +xATSEpoArmed TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been + switched back to the armed position. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Emergency Power Off (EPO) enabled." + --#SUMMARY "EPO armed." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 410 + +xATSTestInitiated TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A scheduled test has been initiated. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the type of test initiated (1=scheduled, 2=manual)." + --#TYPE "APC XATS: Test initiated." + --#SUMMARY "Test initiated." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 411 + +xATSTestCanceled TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The scheduled test has been canceled + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the type of test initiated (1=scheduled, 2=manual)." + --#TYPE "APC XATS: Test canceled." + --#SUMMARY "Test canceled." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 412 + +xATSTestFailed TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "SEVERE: The initiated test has failed. + This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Initiated test failed." + --#SUMMARY "Initiated test failed." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 413 + +xATSTestPassed TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The initiated test has passed + switched back to the armed position. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Initiated test passed." + --#SUMMARY "Initiated test passed." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 414 + +xATSInputContactStateAbnormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, + mtrapargsString02, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: A user input contact on the device has changed to its abnormal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the input contact number. + The fourth argument is the input contact name. + The fifth argument is the input contact state (1=OPEN, 2=CLOSED). + The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED)." + --#TYPE "APC XATS: Input contact has changed to its abnormal state." + --#SUMMARY "Input contact has changed to its abnormal state." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 415 + +xATSInputContactStateNormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, + mtrapargsString02, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A user input contact on the device has changed to its normal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the input contact number. + The fourth argument is the input contact name. + The fifth argument is the input contact state (1=OPEN, 2=CLOSED). + The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED)." + --#TYPE "APC XATS: Input contact has changed to its normal state." + --#SUMMARY "Input contact has changed to its normal state." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 416 + +xATSRemoteStartContactMismatch TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "SEVERE: The state of the generator's Remote Start input + and the ATS's Engine Start output do not match. + This indicates something wrong in the Engine Start wiring, + which must be corrected. This condition will prevent the + generator from being started when needed. + + (See also: xATSGeneratorStatusRemoteStart + and xATSSwitchStatusEngineStartSignal OIDs) + + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Generator/ATS start contact mismatch." + --#SUMMARY "Generator/ATS start contact mismatch." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 417 + +xATSRemoteStartContactMismatchCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Mismatch in the state of the generator's + Remote Start input and the ATS's Engine Start output as been resolved. + This indicates something wrong in the Engine Start wiring, + which must be corrected. This condition will prevent the + generator from being started when needed. + + (See also: xATSGeneratorStatusRemoteStart + and xATSSwitchStatusEngineStartSignal OIDs) + + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Generator/ATS start contact mismatch cleared." + --#SUMMARY "Generator/ATS start contact mismatch cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 418 + +xATSDoorOpenAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "WARNING: The XATS exterior panel door is open. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Panel door is open alarm." + --#SUMMARY "Panel door open alarm." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 419 + +xATSDoorOpenAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The external door to the device is closed. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Panel door open alarm cleared." + --#SUMMARY "Panel door open alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 420 + +xATSDCBackupAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "WARNING: The XATS's DC backup has been lost. The XATS will lose power + on Source 1 failure, causing the Engine Start signal to be asserted. + The XATS will then restart from Source 2. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: DC backup failure." + --#SUMMARY "ATS DC backup failure." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 421 + +xATSDCBackupAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: DC backup alarm has been cleared in the device. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: DC backup alarm cleared." + --#SUMMARY "DC backup alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 422 + +-- xATS Generator Traps + +xATSGeneratorLowCoolantLevelAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Low coolant level has been detected in the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator low coolant level alarm." + --#SUMMARY "Generator low coolant level alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 423 + +xATSGeneratorLowCoolantLevelAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The detected low coolant level has been cleared in the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator low coolant level alarm cleared." + --#SUMMARY "Generator low coolant level alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 424 + +xATSGeneratorVeryLowCoolantLevelAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Very low coolant level has been detected in the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator very low coolant level alarm." + --#SUMMARY "Generator very low coolant level alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 425 + +xATSGeneratorVeryLowCoolantLevelAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The detected Very low coolant level has been cleared in the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator very low coolant level alarm cleared." + --#SUMMARY "Generator very low coolant level alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 426 + +xATSGeneratorHighCoolantTempAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: High coolant temperature has been detected in the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator high coolant temperature alarm." + --#SUMMARY "Generator high coolant temperature alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 427 + +xATSGeneratorHighCoolantTempAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The detected high coolant temperature has been cleared in the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator high coolant temperature alarm cleared." + --#SUMMARY "Generator high coolant temperature alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 428 + +xATSGeneratorVeryHighCoolantTempAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Very high coolant temperature has been detected in the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator very high coolant temperature alarm." + --#SUMMARY "Generator very high coolant temperature alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 429 + +xATSGeneratorVeryHighCoolantTempAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The Very high coolant temperature condition has been cleared in the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator very high coolant temperature alarm cleared." + --#SUMMARY "Generator very high coolant temperature alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 430 + +xATSGeneratorLowCoolantTempAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: Low coolant temperature has been detected in the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator low coolant temperature alarm." + --#SUMMARY "Generator low coolant temperature alarm." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 431 + +xATSGeneratorLowCoolantTempAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The low coolant temperature condition has been cleared in the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator low coolant temperature alarm cleared." + --#SUMMARY "Generator low coolant temperature alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 432 + +xATSGeneratorLowOilLevelAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Low oil level has been detected in the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator low oil level alarm." + --#SUMMARY "Generator low oil level alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 433 + +xATSGeneratorLowOilLevelAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Low oil level alarm has been cleared in the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator low oil level alarm cleared." + --#SUMMARY "Generator low oil level alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 434 + +xATSGeneratorLowBatteryVoltDuringCrankAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The generator's battery voltage has been detected + as low while cranking the engine. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Low batt. voltage while cranking alarm." + --#SUMMARY "Generator low battery volts while cranking alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 435 + +xATSGeneratorLowBatteryVoltDuringCrankAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The generator's low battery voltage while + cranking condition has been cleared. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "XGEN: Generator low batt. voltage while cranking alarm cleared." + --#SUMMARY "Generator low battery volts while cranking alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 436 + +xATSGeneratorVeryLowBatteryVoltDuringCrankAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The generator's battery voltage has been detected + as very low while cranking the engine. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "XGEN: Generator v.low battery voltage while cranking alarm." + --#SUMMARY "Generator v.low battery volts while cranking alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 437 + +xATSGeneratorVeryLowBatteryVoltDuringCrankAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The generator's high battery voltage while + cranking condition has been cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "XGEN: Generator v.low batt volt, while cranking alarm cleared." + --#SUMMARY "Generator v.low battery volts while cranking alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 438 + +xATSGeneratorEStop TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "SEVERE: The generator's emergency stop input has been activated. + After the emergency stop signal has been removed, the E-Stop condition + must be cleared before the generator can be started again. + E-Stop conditions can only be cleared via the generator front panel. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code. + The fourth argument is the type of E-Stop (1=LOCAL, 2=REMOTE)." + --#TYPE "APC XGEN: Generator emergency stop engaged." + --#SUMMARY "Generator emergency stop engaged." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE NONOPERATIONAL + ::= 439 + +xATSGeneratorEStopCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The generator's emergency stop condition has been cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code. + The fourth argument is the type of E-Stop (1=LOCAL, 2=REMOTE)." + --#TYPE "APC XGEN: Generator emergency stop condition cleared." + --#SUMMARY "Generator emergency stop condition cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 440 + +xATSGeneratorHighBatteryVolt TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: The generator's battery voltage has been detected as high. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator high battery voltage." + --#SUMMARY "Generator high battery volts." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 441 + +xATSGeneratorHighBatteryVoltCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The detected high battery voltage has been cleared, on the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator high battery voltage condition cleared." + --#SUMMARY "Generator high battery volts condition cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 442 + +xATSGeneratorLowBatteryVolt TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The generator's battery voltage has been detected as low. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator low battery voltage." + --#SUMMARY "Generator low battery volts." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 443 + +xATSGeneratorLowBatteryVoltCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The detected low battery voltage has been cleared, on the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator low battery voltage condition cleared." + --#SUMMARY "Generator low battery volts condition cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 444 + +xATSGeneratorControlSwitchNotAuto TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The control switch on the generator is not in auto position. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator not-in-automatic mode." + --#SUMMARY "Generator not-in-auto." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 445 + +xATSGeneratorControlSwitchNotAutoCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The control switch on the generator is in auto position. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator automatic mode restored." + --#SUMMARY "Generator not-in-auto cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 446 + +xATSGeneratorLowOilPressure TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The generator's oil pressure has been detected as low. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator low oil pressure." + --#SUMMARY "Generator low oil pressure." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 447 + +xATSGeneratorLowOilPressureCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The detected low oil pressure has been cleared, on the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator low oil pressure condition cleared." + --#SUMMARY "Generator low oil pressure condition cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 448 + +xATSGeneratorVeryLowOilPressure TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The generator's oil pressure has been detected as very low. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator v.low oil pressure." + --#SUMMARY "Generator v.low oil pressure." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 449 + +xATSGeneratorVeryLowOilPressureCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The detected v.low oil pressure has been cleared, on the generator. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator v.low oil pressure condition cleared." + --#SUMMARY "Generator v.low oil pressure condition cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 450 + +xATSGeneratorOverload TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The generator is overloaded. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator is in overload event." + --#SUMMARY "Generator on overload event." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 451 + +xATSGeneratorOverloadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The generator is running within loading limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator is in overload event cleared." + --#SUMMARY "Generator on overload event cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 452 + +xATSGeneratorLowACVEvent TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The generator AC voltage is outside the acceptable bounds. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: State of the Generator AC voltage." + --#SUMMARY " State of the Generator AC voltage." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 453 + +xATSGeneratorLowACVEventCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The generator AC voltage is within normal bounds. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: State of the Generator AC voltage cleared." + --#SUMMARY "State of the Generator AC voltage cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 454 + +xATSGeneratorHighACVEvent TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The generator AC voltage is outside the acceptable bounds. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: State of the Generator AC voltage." + --#SUMMARY " State of the Generator AC voltage." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 455 + +xATSGeneratorHighACVEventCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The generator AC voltage is within normal bounds. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: State of the Generator AC voltage cleared." + --#SUMMARY "State of the Generator AC voltage cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 456 + +xATSGeneratorOverspeed TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The generator is running over the acceptable RPM. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator overspeed condition." + --#SUMMARY "Generator overspeed condition." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 457 + +xATSGeneratorOverspeedCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The generator overspeed shutdown has been cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator overspeed condition cleared." + --#SUMMARY "Generator overspeed condition cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 458 + +xATSGeneratorEngineCold TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The generator engine is cold, may not start. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator engine is cold, may not start." + --#SUMMARY "Generator engine is cold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 459 + +xATSGeneratorEngineColdCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The engine is not cold to start. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Engine is cold to start condition cleared." + --#SUMMARY "Engine is cold to start condition cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 460 + +xATSGeneratorOutputBreakerOpen TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The generators output breaker has been detected as open. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator output breaker open alarm." + --#SUMMARY "Generator output breaker open." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE NONOPERATIONAL + ::= 461 + +xATSGeneratorOutputBreakerOpenCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The engine is not cold to start. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator output breaker open alarm cleared." + --#SUMMARY "Generator output breaker open cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 462 + +xATSGeneratorLowFuelLevelAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: The tank fuel level is below the limits specified + in the xATSGeneratorFuelSystemLowFuelLevelThreshold OID. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the measured fuel level in percent of full." + --#TYPE "APC XGEN: Low fuel level alarm." + --#SUMMARY "Generator low fuel level alarm." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 463 + +xATSGeneratorLowFuelLevelAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The tank fuel level is back above the specified limit. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XGEN: Low fuel level alarm cleared." + --#SUMMARY "Generator low fuel level alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 464 + +xATSGeneratorVeryLowFuelLevelAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The tank fuel level is below the low threshold limits. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the measured tank fuel level in percent of full." + --#TYPE "APC XGEN: Very Low fuel level alarm." + --#SUMMARY "Generator very low fuel level alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 465 + +xATSGeneratorVeryLowFuelLevelAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The detected low tank level has been cleared in the device. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XGEN: Very low fuel level alarm cleared." + --#SUMMARY "Generator very low fuel level alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 466 + +xATSGeneratorLowRunTimeAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: The estimated runtime is below the limits specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the estimated runtime in hours." + --#TYPE "APC XGEN: Low run time alarm." + --#SUMMARY "Generator low run time alarm." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 467 + +xATSGeneratorLowRunTimeAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The detected low runtime has been cleared in the device. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XGEN: Low run time alarm cleared." + --#SUMMARY "Generator low run time alarm." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 468 + +xATSGeneratorVeryLowRunTimeAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The estimated runtime is below the limits specified + in the xATSGeneratorFuelSystemVeryLowRunTimeThreshold OID. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the estimated runtime in hours." + --#TYPE "APC XGEN: Very low run time alarm." + --#SUMMARY "Generator very low run time alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 469 + +xATSGeneratorVeryLowRunTimeAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The detected low runtime has been cleared in the device. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XGEN: Very low run time alarm cleared." + --#SUMMARY "Generator very low run time alarm." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 470 + +xATSGeneratorServiceDueAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "WARNING: The generator is due for scheduled service. + Generation of this alarm is based on calendar days since + and/or actual generator run-hours since last service. + This alarm is cleared using the xATSGeneratorServiceResetRecord OID. + + (See also: xATSGeneratorServiceCalendarIntervalThreshold + and xATSGeneratorServiceRunHoursThreshold OIDs) + + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Generator scheduled maintenance is due." + --#SUMMARY "Generator maintenance due." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 471 + +xATSGeneratorServiceDueAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The generator's service registers have been reset. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: Generator service due alarm is cleared." + --#SUMMARY "Generator service alarm is cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 472 + +xATSGeneratorShutdown TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The generator is shutdown. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator shutdown." + --#SUMMARY "Generator shutdown" + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 473 + +xATSGeneratorShutdownCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The generator shutdown alarm is cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator shutdown is cleared." + --#SUMMARY "Generator shutdown is cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 474 + +xATSGeneratorBatteryCharger TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The generator battery charger is nonfunctional. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator batt. charger is nonfunctional." + --#SUMMARY "Generator battery charger is nonfunctional" + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 475 + +xATSGeneratorBatteryChargerCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Fault in the generator battery charger is cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Fault in the generator battery charger is cleared." + --#SUMMARY "Fault in the generator battery charger is cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 476 + +xATSGeneratorGenericEvent TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: Any generic generator event. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator generic event." + --#SUMMARY "Generator generic event." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 477 + +xATSGeneratorGenericEventCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Generated generic generator event is cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generic generator event is cleared." + --#SUMMARY "Generic generator event is cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 478 + +-- xPDU Traps (part 2) + +xPDUInternalCommErrorCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Internal communication has been restored. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XPDU: Internal Communication error cleared." + --#SUMMARY "Communication error cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 479 + + +xPDUSystemStateAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The PDU's breakers (Q1, Q2 & Q3) are in a configuration that might lead + to system unavailability. it may signify a temporary condition, when the breakers + are placed in an atypical manner as the user transitions to (UPS OPERATION or MAINTENANCE BYPASS) + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the type of state change (1=NO UPS INPUT, 2=NO PANEL FEED, 3=ATYPICAL BYPASS MODE). + note: The NO_PANEL_FEED alarm is applicable only for PDUs with system bypass." + --#TYPE "APC XPDU: System state change alarm." + --#SUMMARY "PDU state change alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 480 + +xPDUSystemStateAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The PDU's breakers (Q1, Q2 & Q3) are set in a configuration + that is a non-alarm state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the type of state change (1=NO UPS INPUT, 2=NO PANEL FEED, 3=ATYPICAL BYPASS MODE). + note: The NO_PANEL_FEED alarm is applicable only for PDUs with system bypass." + --#TYPE "APC XPDU: Normal system state change." + --#SUMMARY "PDU normal state change." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 481 + +xPDUEpoTestMode TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString } + DESCRIPTION + "WARNING: The device's Emergency Power Off (EPO) circuit has been + switched back to the test position. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XPDU: Emergency Power Off (EPO) in test mode." + --#SUMMARY "EPO disabled." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 482 + +xPDUEpoArmed TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been + switched back to the armed position. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XPDU: Emergency Power Off (EPO) enabled." + --#SUMMARY "EPO armed." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 483 + +xPDUFuseBlownAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: One or more fuses in this PDU have been detected as open. + These fuses are in the feed to the UPS associated with this PDU. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1, 2=L2, 3=L3)." + --#TYPE "APC XPDU: Check fuse alarm." + --#SUMMARY "Fuse detected opened." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 484 + +xPDUFuseBlownAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A previous check fuse alarm in this PDU has cleared. + These fuses are in the feed to the UPS associated with this PDU. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase (1=L1, 2=L2, 3=L3)." + --#TYPE "APC XPDU: Check fuse alarm cleared." + --#SUMMARY "Fuse alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 485 + +xPDUBreakerPositionAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, + mtrapargsInteger, mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "SEVERE: A PDU breaker is in a state that compromises system availability. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the breaker (1=MAIN INPUT, 2=BYPASS INPUT, 3=CROSS TIE, 4=OUTPUT). + note: The OUTPUT breaker position alarm is applicable only for PDUs with no system bypass. + The fourth argument is the breaker position (1=OPEN, 2=CLOSED)." + --#TYPE "APC XPDU: Breaker position alarm." + --#SUMMARY "Breaker position alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 486 + +xPDUBreakerPositionAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A PDU breaker is no longer in a state that compromises system availability. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the breaker (1=MAIN INPUT, 2=BYPASS INPUT, 3=CROSS TIE, 4=OUTPUT). + note: The OUTPUT breaker position alarm cleared is applicable only for PDUs with no system bypass." + --#TYPE "APC XPDU: Breaker position alarm cleared." + --#SUMMARY "Breaker alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 487 + +xPDUBreakerChangeEvent TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A system breaker or switch within the device has changed state. + They are generated when any of the Q1, Q2 or Q3 breakers have changed states. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the breaker that has changed + (1=UPS FEED (Q1), 2=UPS OUTPUT(Q2), 3=MAINTENANCE BYPASS (Q3). + The fourth argument is the state of the breaker that has changed (1=OPEN, 2=CLOSED). + The fifth argument is a 8-bit field representing the state of all breakers in the system, + when any of one of the Q1, Q2 or Q3 breakers have changed state. + + The bit map is represented in the following manner (b7, b6 ... b0) + b0 - UPS FEED (Q1) + b1 - MAINTENANCE BYPASS (Q3) + b2 - UPS OUTPUT (Q2) + b3 - MAIN INPUT + b4 - BYPASS INPUT + b5 - CROSS-TIE OUTPUT + + Example: value of 60 (0x3C) indicates that the CROSS_TIE, BYPASS and MAIN INPUT, and Q2 breakers + are CLOSED and Q3, Q1 breakers are OPEN." + --#TYPE "APC XPDU: Breaker/switch change event." + --#SUMMARY "Breaker/switch change event." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 488 + +xPDUDataCommMismatchError TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString } + DESCRIPTION + "SEVERE: A data incompatibility exists within the device. This + is typically the result of mismatches between firmware revisions + of the transfer switch controller and the Network Management interface. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XPDU: Data mismatch error." + --#SUMMARY "XPDU data mismatch error." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 489 + +xPDUDataCommMismatchErrorCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The internal data incompatibility has been resolved. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XPDU: data mismatch error cleared." + --#SUMMARY "XPDU data mismatch error cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 490 + +xPDUSystemInMaintenanceBypassMode TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString } + DESCRIPTION + "WARNING: The PDU state has changed to maintenance bypass mode. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XPDU: System state changed to maintenance bypass." + --#SUMMARY "PDU state changed to maintenance bypass." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 491 + +xPDUSystemInUPSOperationalMode TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The PDU state has changed to UPS operational mode. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XPDU: System state changed to UPS operational." + --#SUMMARY "PDU state changed to UPS operational." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 492 + +xATSGeneratorFuelTankRuptureAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: Detected a rupture in the inner wall of the generator fuel tank. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator inner wall rupture alarm." + --#SUMMARY "Generator inner wall rupture alarm." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 493 + +xATSGeneratorFuelTankRuptureAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The rupture in the inner wall of the generator is not detected. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator inner wall rupture alarm cleared." + --#SUMMARY "Generator inner wall rupture alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 494 + +xATSGeneratorGroundFaultAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Generator ground fault alarm. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator ground fault alarm." + --#SUMMARY "Generator ground fault alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 495 + +xATSGeneratorGroundFaultAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Generator ground fault alarm cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the OEM's fault/event code." + --#TYPE "APC XGEN: Generator ground fault alarm cleared." + --#SUMMARY "Generator ground fault alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 496 + +xATSOutputLoadPoweredByGeneratorAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: The system load on the output of the ATS is being powered by source 2 (generator). + The first argument is the host device serial number. + The second argument is the host device name. + The third argument indicates if the load is powered by the generator, + when 'load testing' the generator (1 = LIVE, 2 = TEST)." + --#TYPE "APC XATS: System load powered by generator alarm." + --#SUMMARY "System load powered by generator." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 497 + +xATSOutputLoadPoweredByGeneratorAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The system load on the output of the ATS is no longer being powered by source 2 (generator). + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: System load powered by generator alarm cleared." + --#SUMMARY "System load powered by generator alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 498 + +xAPCControllerFirmwareUpdateTransferStart TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString05, mtrapargsString04, mtrapargsString02, mtrapargsString03, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Start controller firmware transfer in the device. + The first argument is the host device serial number. + The second argument is the host model name that initiated the transfer. + The third argument is the name of the file that is transferred. + The fourth argument is the updated revision of the file, if available + The fifth argument is the reason for the update, if available + (1=User request, 2=Automatic upgrade by NMC, 3=Unknown)." + --#TYPE "APC: Start update transfer." + --#SUMMARY "Start update transfer." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 499 + +xAPCControllerFirmwareUpdateTransferComplete TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString05, mtrapargsString04, mtrapargsString02, + mtrapargsString03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Transfer of controller firmware was completed in the device. + The first argument is the host device serial number. + The second argument is the host device model name that completed the transfer. + The third argument is the name of the file that was transferred. + The fourth argument is the revision of the file that was transferred, if available." + --#TYPE "APC : Update transfer complete." + --#SUMMARY "Update transfer complete." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 500 + + +xAPCControllerFirmwareUpdateTransferFailed TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString05, mtrapargsString04, mtrapargsString02, + mtrapargsString03, mtrapargsString } + DESCRIPTION + "SEVERE: Transfer of controller firmware failed. + The first argument is the host device serial number. + The second argument is the host device model name that failed to transfer. + The third argument is the name of the file that failed the transfer, if available. + The fourth argument is the reason for failure." + --#TYPE "APC: Update transfer failed." + --#SUMMARY "Update transfer failed." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 501 + +upsPfcInputRelayFailure TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The PFC (Power Factor Correction) input relay failure exists." + --#TYPE "APC UPS: The PFC input relay failure exists." + --#SUMMARY "The PFC (Power Factor Correction) input relay failure exists." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 502 + +upsPfcInputRelayFailureCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The PFC (Power Factor Correction) input relay failure cleared." + --#TYPE "APC UPS: The PFC input relay failure cleared." + --#SUMMARY "The PFC (Power Factor Correction) input relay failure cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 503 + +upsInverterOverTemperature TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The inverter over temperature condition exists." + --#TYPE "APC UPS: The inverter over temperature condition exists." + --#SUMMARY "The inverter over temperature condition exists." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 504 + +upsInverterOverTemperatureCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The inverter over temperature condition cleared." + --#TYPE "APC UPS: The inverter over temperature condition cleared." + --#SUMMARY "The inverter over temperature condition cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 505 + +upsBatteryOverVoltage TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The battery over voltage condition exists." + --#TYPE "APC UPS: The battery over voltage condition exists." + --#SUMMARY "The battery over voltage condition exists." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 506 + +upsBatteryOverVoltageCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The battery over voltage condition cleared." + --#TYPE "APC UPS: The battery over voltage condition cleared." + --#SUMMARY "The battery over voltage condition cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 507 + +upsEepromFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The EEPROM fault exists." + --#TYPE "APC UPS: The EEPROM fault exists." + --#SUMMARY "The EEPROM fault exists." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 508 + +upsEepromFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The EEPROM fault cleared." + --#TYPE "APC UPS: The EEPROM fault cleared." + --#SUMMARY "The EEPROM fault cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 509 + +-- rARU Traps (part 2) + +aruFanRuntimeAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: The total running hours for a fan has exceeded + the run hour threshold. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name. + The fifth argument indicates which fan in the ARU." + --#TYPE "APC ARU: Fan Runhour Warning." + --#SUMMARY "Fan Runhour Alarm." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 510 + +aruFanRuntimeAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The total running hours for a fan is no longer + above the fan runhour threshold. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name. + The fifth argument indicates which fan in the ARU." + --#TYPE "APC ARU: Fan Runhour Alarm Cleared." + --#SUMMARY "Fan Runhour Alarm Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 511 + + +aruFanPoorPerformanceAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: Poor fan performance has been detected in the ARU, + indicating that the fan may be close to failing. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name. + The fifth argument indicates which fan in the ARU." + --#TYPE "APC ARU: Poor Fan Performance Warning." + --#SUMMARY "Fan Health Alarm." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 512 + +aruFanPoorPerformanceAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Fan performance is no longer degraded. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name. + The fifth argument indicates which fan in the ARU." + --#TYPE "APC ARU: Poor Fan Performance Warning Cleared." + --#SUMMARY "Fan Health Alarm Cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 513 + +aruRedundantPowerLostAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsString } + DESCRIPTION + "WARNING: One of the redundant line cords on the ARU is no longer receiving AC power. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name." + --#TYPE "APC ARU: Redundant AC Input is not Present." + --#SUMMARY "AC Redundancy Lost." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 514 + +aruRedundantPowerLostAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { emsIdentSerialNumber, emsIdentEMSName, + rARUStatusAruIndex, rARUStatusAruName, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Line-cord redundancy has been restored to the ARU. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the ARU number. + The fourth argument is the ARU name." + --#TYPE "APC ARU: Redundant AC Input is Present." + --#SUMMARY "AC Redundancy Restored." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 515 + +apcDeviceConfigChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A device configuration change has been made on the device. + The first argument is the device serial number. + The second argument is the device name. + The third argument is a secondary device id number." + --#TYPE "APC: A device configuration change on a device." + --#SUMMARY "A device configuration change has been made on a device." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 516 + +apcEnvSensorConnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A sensor has been connected to the host device. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Sensor Connected." + --#SUMMARY "Sensor Connected." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 517 + +apcEnvSensorDisconnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: A sensor has been disconnected from the device. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Sensor Disconnected." + --#SUMMARY "Sensor Disconnected." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 518 + +apcEnvMaxTempThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: Max temperature threshold violated on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Max temperature threshold violation." + --#SUMMARY "Max temperature threshold violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 519 + +apcEnvMaxTempThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Max temperature threshold violation cleared on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Max temperature threshold violation cleared." + --#SUMMARY "Max temperature threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 520 + +apcEnvHighTempThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "WARNING: High temperature threshold violated on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: High temperature threshold violation." + --#SUMMARY "High temperature threshold violation." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 521 + +apcEnvHighTempThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: High temperature threshold violation cleared on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: High temperature threshold violation cleared." + --#SUMMARY "High temperature threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 522 + +apcEnvLowTempThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "WARNING: Low temperature threshold violated on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Low temperature threshold violation." + --#SUMMARY "Low temperature threshold violation." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 523 + +apcEnvLowTempThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Low temperature threshold violation cleared on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Low temperature threshold violation cleared." + --#SUMMARY "Low temperature threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 524 + +apcEnvMinTempThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: Min temperature threshold violated on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Min temperature threshold violation." + --#SUMMARY "Min temperature threshold violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 525 + +apcEnvMinTempThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Min temperature threshold violation cleared on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The sixth argument is the sensor number. + The seventh argument is the sensor name." + --#TYPE "APC ENV: Min temperature threshold violation cleared." + --#SUMMARY "Min temperature threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 526 + +apcEnvSTIncTempRateViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: Short-term increasing temperature rate violated on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Short-term inc. temp rate violation." + --#SUMMARY "Short-term inc. temp rate violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 527 + +apcEnvSTIncTempRateViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Short-term increasing temperature rate cleared on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Short-term inc. temp rate violation cleared." + --#SUMMARY "Short-term inc. temp rate violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 528 + +apcEnvSTDecTempRateViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: Short-term decreasing temperature rate violated on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Short-term dec. temp rate violation." + --#SUMMARY "Short-term dec. temp rate violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 529 + +apcEnvSTDecTempRateViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Short-term decreasing temperature rate cleared on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Short-term dec. temp rate violation cleared." + --#SUMMARY "Short-term dec. temp rate violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 530 + +apcEnvLTIncTempRateViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: Long-term increasing temperature rate violated on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Long-term inc. temp rate violation." + --#SUMMARY "Long-term inc. temp rate violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 531 + +apcEnvLTIncTempRateViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Long-term increasing temperature rate cleared on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Long-term inc. temp rate violation cleared." + --#SUMMARY "Long-term inc. temp rate violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 532 + +apcEnvLTDecTempRateViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: Long-term decreasing temperature rate violated on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Long-term dec. temp rate violation." + --#SUMMARY "Long-term dec. temp rate violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 533 + +apcEnvLTDecTempRateViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Long-term decreasing temperature rate cleared on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Long-term dec. temp rate violation cleared." + --#SUMMARY "Long-term dec. temp rate violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 534 + +apcEnvMaxHumidityThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: Max humidity threshold violated on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Max humidity threshold violation." + --#SUMMARY "Max humidity threshold violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 535 + +apcEnvMaxHumidityThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Max humidity threshold violation cleared on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Max humidity threshold violation cleared." + --#SUMMARY "Max humidity threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 536 + +apcEnvHighHumidityThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "WARNING: High humidity threshold violated on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: High humidity threshold violation." + --#SUMMARY "High humidity threshold violation." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 537 + +apcEnvHighHumidityThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: High humidity threshold violation cleared on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: High humidity threshold violation cleared." + --#SUMMARY "High humidity threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 538 + +apcEnvLowHumidityThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "WARNING: Low humidity threshold violated on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Low humidity threshold violation." + --#SUMMARY "Low humidity threshold violation." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 539 + +apcEnvLowHumidityThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Low humidity threshold violation cleared on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Low humidity threshold violation cleared." + --#SUMMARY "Low humidity threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 540 + +apcEnvMinHumidityThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: Min humidity threshold violated on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Min humidity threshold violation." + --#SUMMARY "Min humidity threshold violation." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 541 + +apcEnvMinHumidityThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Min humidity threshold violation cleared on the sensor. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the sensor number. + The fifth argument is the sensor name." + --#TYPE "APC ENV: Min humidity threshold violation cleared." + --#SUMMARY "Min humidity threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 542 + +apcBeaconConnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A beacon has been connected to the device. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number." + --#TYPE "APC: Beacon Connected." + --#SUMMARY "Beacon Connected." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 543 + +apcBeaconDisconnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsString } + DESCRIPTION + "SEVERE: A beacon has been disconnected from the device. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. " + --#TYPE "APC: Beacon Disconnected." + --#SUMMARY "Beacon Disconnected." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 544 + +apcBeaconOn TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A beacon has gone on (activated). + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. " + --#TYPE "APC: Beacon On." + --#SUMMARY "Beacon On." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 545 + +apcBeaconOff TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A beacon has gone off (deactivated). + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. " + --#TYPE "APC: Beacon Off." + --#SUMMARY "Beacon Off." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 546 + +apcOutletStateAbnormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger, mtrapargsString04, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "WARNING: An outlet on the device has changed to its abnormal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the outlet number. + The fifth argument is the outlet name. + The sixth argument is the current outlet state (1=ON, 2=OFF). + The seventh argument is the configured normal outlet state (1=ON, 2=OFF)." + --#TYPE "APC: Outlet has changed to its abnormal state." + --#SUMMARY "Outlet has changed to its abnormal state." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 547 + +apcOutletStateNormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger, mtrapargsString04, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An outlet on the device has changed to its normal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the outlet number. + The fifth argument is the outlet name. + The sixth argument is the current outlet state (1=ON, 2=OFF). + The seventh argument is the configured normal outlet state (1=ON, 2=OFF)." + --#TYPE "APC: Outlet has changed to its normal state." + --#SUMMARY "Outlet has changed to its normal state." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 548 + +apcOutputRelayStateAbnormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger, + mtrapargsString04, mtrapargsInteger02, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "WARNING: An output relay on the device has changed to its abnormal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the output relay number. + The fifth argument is the output relay name. + The sixth argument is the current output relay state (1=CLOSED, 2=OPEN). + The seventh argument is the configured normal output relay state (1=CLOSED, 2=OPEN)." + --#TYPE "APC: Output Relay has changed to its abnormal state." + --#SUMMARY "Output Relay has changed to its abnormal state." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 549 + +apcOutputRelayStateNormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger, + mtrapargsString04, mtrapargsInteger02, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An output relay on the device has changed to its normal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the output relay number. + The fifth argument is the output relay name. + The sixth argument is the current output relay state (1=CLOSED, 2=OPEN). + The seventh argument is the configured normal output relay state (1=CLOSED, 2=OPEN)." + --#TYPE "APC: Output Relay has changed to its normal state." + --#SUMMARY "Output Relay has changed to its normal state." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 550 + +apcHardwareStateAbnormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + + "SEVERE: The device's hardware is improperly configured and operating outside + normal bounds for the hardware. This can be caused by improper devices being + connected to device ports or Alink Current limit detection. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is a hardware specific state code." + + --#TYPE "APC: Hardware is in an abnormal state." + --#SUMMARY "Hardware is in an abnormal state." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 551 + +apcHardwareStateNormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsInteger04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The device's hardware is in its normal operational state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number." + --#TYPE "APC EMS: Hardware is in a normal state." + --#SUMMARY "Hardware is in its normal state." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 552 + +apcCriticalDiscreteInputContactStateAbnormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger, + mtrapargsString04, mtrapargsInteger02, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: A discrete input contact on the device has changed to its abnormal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the input contact number. + The fifth argument is the input contact name. + The sixth argument is the input contact state (1=CLOSED, 2=OPEN). + The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN)." + --#TYPE "APC: Discrete input contact has changed to its abnormal state." + --#SUMMARY "Discrete input contact has changed to its abnormal state." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 553 + +apcCriticalDiscreteInputContactStateNormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger, + mtrapargsString04, mtrapargsInteger02, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A discrete input contact on the device has changed to its normal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the input contact number. + The fifth argument is the input contact name. + The sixth argument is the input contact state (1=CLOSED, 2=OPEN). + The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN)." + --#TYPE "APC: Discrete input contact has changed to its normal state." + --#SUMMARY "Discrete input contact has changed to its normal state." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 554 + +apcWarningDiscreteInputContactStateAbnormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger, + mtrapargsString04, mtrapargsInteger02, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "WARNING: A discrete input contact on the device has changed to its abnormal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the input contact number. + The fifth argument is the input contact name. + The sixth argument is the input contact state (1=CLOSED, 2=OPEN). + The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN)." + --#TYPE "APC: Discrete input contact has changed to its abnormal state." + --#SUMMARY "Discrete input contact has changed to its abnormal state." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 555 + +apcWarningDiscreteInputContactStateNormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger, + mtrapargsString04, mtrapargsInteger02, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A discrete input contact on the device has changed to its normal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the input contact number. + The fifth argument is the input contact name. + The sixth argument is the input contact state (1=CLOSED, 2=OPEN). + The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN)." + --#TYPE "APC: Discrete input contact has changed to its normal state." + --#SUMMARY "Discrete input contact has changed to its normal state." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 556 + +apcInformationalDiscreteInputContactStateAbnormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger, + mtrapargsString04, mtrapargsInteger02, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A discrete input contact on the device has changed to its abnormal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the input contact number. + The fifth argument is the input contact name. + The sixth argument is the input contact state (1=CLOSED, 2=OPEN). + The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN)." + --#TYPE "APC: Discrete input contact has changed to its abnormal state." + --#SUMMARY "Discrete input contact has changed to its abnormal state." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 557 + +apcInformationalDiscreteInputContactStateNormal TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger, + mtrapargsString04, mtrapargsInteger02, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A discrete input contact on the device has changed to its normal state. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the input contact number. + The fifth argument is the input contact name. + The sixth argument is the input contact state (1=CLOSED, 2=OPEN). + The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN)." + --#TYPE "APC: Discrete input contact has changed to its normal state." + --#SUMMARY "Discrete input contact has changed to its normal state." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 558 + +apcAnalogInputMaxThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: Maximum threshold violated on an analog input. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the input number. + The fifth argument is the input name." + --#TYPE "APC: Maximum threshold violation on analog input." + --#SUMMARY "Max threshold violation on input." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 559 + +apcAnalogInputMaxThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Maximum threshold violation cleared on the analog input. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the input number. + The fifth argument is the input name." + --#TYPE "APC: Max threshold violation cleared." + --#SUMMARY "Max threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 560 + +apcAnalogInputHighThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "WARNING: High threshold violated on an analog input. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the input number. + The fifth argument is the input name." + --#TYPE "APC: High threshold violation on analog input." + --#SUMMARY "High threshold violation on input." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 561 + +apcAnalogInputHighThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: High threshold violation cleared on the analog input. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the input number. + The fifth argument is the input name." + --#TYPE "APC: High threshold violation cleared." + --#SUMMARY "High threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 562 + +apcAnalogInputLowThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "WARNING: Low threshold violated on an analog input. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the input number. + The fifth argument is the input name." + --#TYPE "APC: Low threshold violation on analog input." + --#SUMMARY "Low threshold violation on input." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 563 + +apcAnalogInputLowThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Low threshold violation cleared on the analog input. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the input number. + The fifth argument is the input name." + --#TYPE "APC: Low threshold violation cleared." + --#SUMMARY "Low threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 564 + +apcAnalogInputMinThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: Minimum threshold violated on an analog input. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the input number. + The fifth argument is the input name." + --#TYPE "APC: Min threshold violation on analog input." + --#SUMMARY "Min threshold violation on input." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 565 + +apcAnalogInputMinThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Minimum threshold violation cleared on the analog input. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is a secondary device id number. + The fourth argument is the input number. + The fifth argument is the input name." + --#TYPE "APC: Min threshold violation cleared." + --#SUMMARY "Min threshold violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 566 + +apcDeviceClearLostComms TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Lost communications reset command has been issued. + The first argument is the device serial number. + The second argument is the device name. + The third argument is a secondary device id number." + --#TYPE "APC: Lost communications reset command has been issued." + --#SUMMARY "Lost communications reset command has been issued." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + + ::= 567 + +apcDeviceConnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A device has been connected to the host. + The first argument is the host serial number. + The second argument is the host name. + The third argument is the device number. + The fourth argument is the device name." + --#TYPE "APC: Device Connected." + --#SUMMARY "Device Connected." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 568 + +apcDeviceDisconnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: A device has been disconnected from the host. + The first argument is the host serial number. + The second argument is the host name. + The third argument is the device number. + The fourth argument is the device name." + --#TYPE "APC: Device Disconnected." + --#SUMMARY "Device Disconnected." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 569 + +apcUnregisteredUserAccessDenied TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString04, + mtrapargsInteger, mtrapargsString05, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: An unregistered user has tried to access the device. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argumant is the door identifier. + The fifth argument is the unregistered user's RFID." + --#TYPE "APC: Unregistered user." + --#SUMMARY "Unregistered user." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 570 + + +apcRegisteredUserAccessDenied TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString04, + mtrapargsInteger, mtrapargsString05, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: A registered user has been denied access to the device. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argumant is the door identifier. + The fifth argument is the user name." + --#TYPE "APC: Access denied." + --#SUMMARY "Access denied." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 571 + +apcRegisteredUserConfigChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsString05, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: Registered user configuration change. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the user name." + --#TYPE "APC: Registered user configuration change." + --#SUMMARY "Registered user configuration change." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 572 + +apcDoorUnlocked TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString04, + mtrapargsInteger, mtrapargsString05, mtrapargsInteger02, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: A door has been unlocked. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier. + The fifth argument is the door access user. + The sixth argument is the door access type." + --#TYPE "APC: Door unlocked." + --#SUMMARY "Door unlocked." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 573 + +apcDoorLocked TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString04, + mtrapargsInteger, mtrapargsString05, mtrapargsInteger02, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: A door has been locked. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier. + The fifth argument is the door access user. + The sixth argument is the door access type." + --#TYPE "APC: Door locked." + --#SUMMARY "Door locked." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 574 + +apcHandleOpened TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: A door handle has been opened. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: Door handle opened." + --#SUMMARY "Door handle opened." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 575 + +apcHandleClosed TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: A door handle has been closed. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: Door handle closed." + --#SUMMARY "Door handle closed." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 576 + + +apcDoorOpened TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: A door has been opened. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: Door opened." + --#SUMMARY "Door opened." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 577 + +apcDoorClosed TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: A door has been closed. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: Door closed." + --#SUMMARY "Door closed." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 578 + + -- trap number 579 available + + +apcKeyOverrideUnlocked TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "SEVERE: Key override unlock has occurred. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: Key override unlock has occurred." + --#SUMMARY "Key override unlock has occurred." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 580 + + +apcKeyOverrideLocked TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: Key override lock has occurred. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: Key override lock has occurred." + --#SUMMARY "Key override lock has occurred." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 581 + +apcForcedEntry TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "SEVERE: A forced entry condition has occurred. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: A forced entry condition has occurred." + --#SUMMARY "A forced entry has occurred." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 582 + +apcForcedEntryCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: A forced entry condition has been cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: A forced entry condition has been cleared." + --#SUMMARY "A forced entry has been cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 583 + + +apcRelockTimeout TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "SEVERE: A relock timout has occurred. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: Relock timout." + --#SUMMARY "Relock timeout." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 584 + +apcRelockTimeoutCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: A relock timout has been cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: relock timout has been cleared." + --#SUMMARY "Relock timout has been cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 585 + +apcDoorSenseDisconnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "SEVERE: A door sensor was disconnected. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: A door sensor was disconnected." + --#SUMMARY "A door sensor was disconnected." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 586 + +apcDoorSenseConnected TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: A forced entry condition has been cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: A door sensor was connected." + --#SUMMARY "A door sensor was connected." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 587 + + +apcDoorLostComms TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "SEVERE: Communications have been lost with the door. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: A door has lost communications." + --#SUMMARY "A door has lost communications." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 588 + +apcDoorEstablishedComms TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: Communications have been established with the door. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: A door has established communications." + --#SUMMARY "A door has established communications." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 589 + + + +apcRegisteredUserAccessChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsString05, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: Registered user access changed. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the user name." + --#TYPE "APC: Registered user access change." + --#SUMMARY "Registered user access change." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 590 + + +apcUnregisteredUserStatusChange TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsString05, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: Unregistered user status changed. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the user name." + --#TYPE "APC: Unregistered user status change." + --#SUMMARY "Unregistered user status change." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 591 + +apcDeviceClearUserConfigs TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: User configurations reset command has been issued. + The first argument is the device serial number. + The second argument is the device name. + The third argument is a secondary device id number." + --#TYPE "APC: User configurations reset command has been issued." + --#SUMMARY "User configurations reset command has been issued." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 592 + +-- Add more events starting at 600 for UPS Devices + +upsBatteryTempSensorFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The battery temperature sensor fault exists." + --#TYPE "APC UPS: The battery temperature sensor fault exists." + --#SUMMARY "The battery temperature sensor fault exists." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 600 + +upsBatteryTempSensorFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The battery temperature sensor fault cleared." + --#TYPE "APC UPS: The battery temperature sensor fault cleared." + --#SUMMARY "The battery temperature sensor fault cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 601 + +upsBatterySoftBusStartFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A battery bus soft start fault exists." + --#TYPE "APC UPS: A battery bus soft start fault exists." + --#SUMMARY "A battery bus soft start fault exists." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 602 + +upsBatterySoftBusStartFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A battery bus soft start fault exists cleared." + --#TYPE "APC UPS: A battery bus soft start fault exists cleared." + --#SUMMARY "A battery bus soft start fault exists cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 603 + +apcOutputShortCircuit TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: An output short circuit condition exists." + --#TYPE "APC Device: An output short circuit condition exists." + --#SUMMARY "An output short circuit condition exists." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 604 + +apcOutputShortCircuitCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An output short circuit condition cleared." + --#TYPE "APC Device: An output short circuit condition cleared." + --#SUMMARY "An output short circuit condition cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 605 + +apcOutputRelayFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: An output relay (or its driver) fault exists." + --#TYPE "APC Device: An output relay (or its driver) fault exists." + --#SUMMARY "An output relay (or its driver) fault exists." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 606 + +apcOutputRelayFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An output relay (or its driver) fault cleared." + --#TYPE "APC Device: An output relay (or its driver) fault cleared." + --#SUMMARY "An output relay (or its driver) fault cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 607 + +upsPfcFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A PFC fault exists." + --#TYPE "APC UPS: A PFC fault exists." + --#SUMMARY "A PFC fault exists." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 608 + +upsPfcFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The PFC fault cleared." + --#TYPE "APC UPS: The PFC fault cleared." + --#SUMMARY "The PFC fault cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 609 + +apcDcBusOverVoltage TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The DC bus voltage is too high." + --#TYPE "APC Devcie: DC bus voltage is too high." + --#SUMMARY "The DC bus voltage is too high." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 610 + +apcDcBusOverVoltageCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The DC bus voltage is too high cleared." + --#TYPE "APC Device: The DC bus voltage is too high cleared." + --#SUMMARY "The DC bus voltage is too high cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 611 + +upsInverterFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The inverter fault exists." + --#TYPE "APC UPS: The inverter fault exists." + --#SUMMARY "The inverter fault exists." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 612 + +upsInverterFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The inverter fault cleared." + --#TYPE "APC UPS: The inverter fault cleared." + --#SUMMARY "The inverter fault cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 613 + +apcAdConverterFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The A/D converter fault exists." + --#TYPE "APC Device: The A/D converter fault exists." + --#SUMMARY "The A/D converter fault exists." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 614 + +apcAdConverterFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The A/D converter fault cleared." + --#TYPE "APC Device: The A/D converter fault cleared." + --#SUMMARY "The A/D converter fault cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 615 + +apcLogicPowerSupplyFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A logic power supply fault exists." + --#TYPE "APC Device: A logic power supply fault exists." + --#SUMMARY "A logic power supply fault exists." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 616 + +apcLogicPowerSupplyFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A logic power supply fault cleared." + --#TYPE "APC Device: A logic power supply fault cleared." + --#SUMMARY "A logic power supply fault cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 617 + +apcTransformerDCImbalanceFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The DC component of the transformer's current is too high." + --#TYPE "APC Device: The DC component of the tformer's curr is too high." + --#SUMMARY "The DC component of the transformer's current is too high." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 618 + +apcTransformerDCImbalanceFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The DC component of the transformer's current is normal." + --#TYPE "APC Device: The DC component of the tformer's curr is normal." + --#SUMMARY "The DC component of the transformer's current is normal." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 619 + +upsBackfeedRelayFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The backfeed relay (or its driver) has a fault." + --#TYPE "UPS Device: The backfeed relay (or its driver) has a fault." + --#SUMMARY "The backfeed relay (or its driver) has a fault." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 620 + +upsBackfeedRelayFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: The backfeed relay (or its driver) has a fault cleared." + --#TYPE "UPS Device: The bfeed rly (or its drver) has a flt cleared." + --#SUMMARY "The backfeed relay (or its driver) has a fault cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 621 + +upsBypassRelayFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A bypass relay (or its driver) has a fault." + --#TYPE "APC Device: A bypass relay (or its driver) has a fault." + --#SUMMARY "A bypass relay (or its driver) has a fault." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 622 + +upsBypassRelayFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A bypass relay (or its driver) has a fault cleared." + --#TYPE "APC Device: A bypass relay (or its driver) has a fault cleared." + --#SUMMARY "A bypass relay (or its driver) has a fault cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 623 + + +xPDUBranchCurrentMinAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: The current in a branch circuit is outside the limits specified for that + branch circuit. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the panel position of the branch circuit (1-based index). + The fourth argument is the measured current in tenths of Amps. + The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated." + --#TYPE "APC XPDU: Branch circuit minimum current alarm." + --#SUMMARY "Branch circuit current is below threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 626 + +xPDUBranchCurrentMinAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The current in a branch circuit is back within the limits + specified for that branch circuit. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the panel position of the branch circuit (1-based index). + The fourth argument is the measured current in tenths of Amps." + --#TYPE "APC XPDU: Branch circuit minimum current alarm cleared." + --#SUMMARY "Branch circuit low current alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 627 + +xPDUBranchCurrentMaxAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: The current in a branch circuit is outside the limits specified for that + branch circuit. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the panel position of the branch circuit (1-based index). + The fourth argument is the measured current in tenths of Amps. + The fifth argument is the threshold, in tenths of Amps, above which the alarm was generated." + --#TYPE "APC XPDU: Branch circuit maximum current alarm." + --#SUMMARY "Branch circuit current is above threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 628 + +xPDUBranchCurrentMaxAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, + mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The current in a branch circuit is back within the limits + specified for that branch circuit. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the panel position of the branch circuit (1-based index). + The fourth argument is the measured current in tenths of Amps." + --#TYPE "APC XPDU: Branch circuit maximum current alarm cleared." + --#SUMMARY "Branch circuit high current alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 629 + + +rPDUOutletLowLoad TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDUOutletStatusIndex, mtrapargsString } + DESCRIPTION + "WARNING: A Rack PDU has violated the outlet low load threshold. + The first argument is the serial number. + The second argument is the device name. + The third argument is the outlet number." + --#TYPE "APC Rack PDU: Violation of outlet low load threshold." + --#SUMMARY "A Rack PDU has violated the outlet low load threshold." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 630 + +rPDUOutletLowLoadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDUOutletStatusIndex, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The outlet low load condition on a Rack PDU has been + cleared. + The first argument is the serial number. + The second argument is the device name. + The third argument is the outlet number." + --#TYPE "APC Rack PDU: Low load condition cleared." + --#SUMMARY "The low load condition on a Rack PDU has been cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 631 + +rPDUOutletNearOverload TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDUOutletStatusIndex, mtrapargsString } + DESCRIPTION + "WARNING: A Rack PDU is near an outlet overload condition. + The first argument is the serial number. + The second argument is the device name. + The third argument is the outlet number." + --#TYPE "APC Rack PDU: Near an overload condition." + --#SUMMARY "A Rack PDU is near an outlet overload condition." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 632 + +rPDUOutletNearOverloadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDUOutletStatusIndex, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The outlet near overload condition on a Rack PDU has + been cleared. + The first argument is the serial number. + The second argument is the device name. + The third argument is the outlet number." + --#TYPE "APC Rack PDU: Outlet Near overload condition has cleared." + --#SUMMARY "Rack PDU outlet near overload condition has cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 633 + +rPDUOutletOverload TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDUOutletStatusIndex, mtrapargsString } + DESCRIPTION + "SEVERE: A Rack PDU is in an overload condition. + The first argument is the serial number. + The second argument is the device name. + The third argument is the outlet number." + --#TYPE "APC Rack PDU: Outlet Overload condition." + --#SUMMARY "A Rack PDU is in an outlet overload condition." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 634 + +rPDUOutletOverloadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, + rPDUOutletStatusIndex, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The outlet overload condition on a Rack PDU has been + cleared. + The first argument is the serial number. + The second argument is the device name. + The third argument is the outlet number." + --#TYPE "APC Rack PDU: Overload condition has cleared." + --#SUMMARY "The outlet overload condition on a Rack PDU has cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 635 + +apcTestTrap TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsInteger02, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Trap used to test SNMP trap functionality. + The first argument is a place holder for test variables." + --#TYPE "APC: Test trap." + --#SUMMARY "Test Trap." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 636 + +baseFanFailureCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Base module fan has been repaired" + --#TYPE "APC UPS: Base module fan has been repaired" + --#SUMMARY "The base module fan has been repaired." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 637 + + + +atsLowLoad TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + atsOutputPhaseIndex, atsOutputBank, mtrapargsString } + DESCRIPTION + "WARNING: ATS has violated the bank or phase low load threshold. + The first argument is the serial number. + The second argument is the product name. + The third argument is the phase number + The fourth argument is the bank number. -1 is returned if bank does not exist." + --#TYPE "APC ATS: Violation of bank or phase low load threshold." + --#SUMMARY "ATS has violated the bank or phase low load threshold." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 638 + +atsLowLoadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + atsOutputPhaseIndex, atsOutputBank, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The bank or phase low load condition on an ATS has been + cleared. + The first argument is the serial number. + The second argument is the product name. + The third argument is the phase number + The fourth argument is the bank number. -1 is returned if bank does not exist." + --#TYPE "APC ATS: Low load condition cleared." + --#SUMMARY "The low load condition on an ATS has been cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 639 + +atsNearOverload TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + atsOutputPhaseIndex, atsOutputBank, mtrapargsString } + DESCRIPTION + "WARNING: ATS has violated the bank or phase near overload threshold. + The first argument is the serial number. + The second argument is the product name. + The third argument is the phase number + The fourth argument is the bank number. -1 is returned if bank does not exist." + --#TYPE "APC ATS: Near an overload condition." + --#SUMMARY "ATS is near a bank or phase overload condition." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 640 + +atsNearOverloadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + atsOutputPhaseIndex, atsOutputBank, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The bank or phase near overload condition on an ATS has + been cleared. + The first argument is the serial number. + The second argument is the product name. + The third argument is the phase number + The fourth argument is the bank number. -1 is returned if bank does not exist." + --#TYPE "APC ATS: Bank or phase near overload condition has cleared." + --#SUMMARY "ATS bank or phase near overload condition has cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 641 + +atsOverload TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + atsOutputPhaseIndex, atsOutputBank, mtrapargsString } + DESCRIPTION + "SEVERE: ATS is in an overload condition. + The first argument is the serial number. + The second argument is the product name. + The third argument is the phase number. + The fourth argument is the bank number. -1 is returned if bank does not exist." + --#TYPE "APC ATS: Bank or Phase Overload condition." + --#SUMMARY "ATS is in overload condition." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 642 + +atsOverloadCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + atsOutputPhaseIndex, atsOutputBank, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The bank or phase overload condition on an ATS has been + cleared. + The first argument is the serial number. + The second argument is the product name. + The third argument is the phase number. + The fourth argument is the bank number. -1 is returned if bank does not exist." + --#TYPE "APC ATS: Overload condition has cleared." + --#SUMMARY "The bank or phase overload condition on an ATS has cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 643 + +atsRMSOverVoltage TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Overvoltage condition violated. + The first argument is the serial number. + The second argument is the product name. + The third argument is an integer representing the source: 0=A, 1=B." + --#TYPE "APC ATS: Overvoltage condition violated." + --#SUMMARY "Overvoltage condition violated." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 644 + +atsRMSOverVoltageCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Overvoltage condition cleared. + The first argument is the serial number. + The second argument is the product name. + The third argument is an integer representing the source: 0=A, 1=B." + --#TYPE "APC ATS: Overvoltage condition cleared." + --#SUMMARY "Overvoltage condition cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 645 + +atsRMSUnderVoltage TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: Undervoltage condition violated. + The first argument is the serial number. + The second argument is the product name. + The third argument is an integer representing the source: 0=A, 1=B." + --#TYPE "APC ATS: Undervoltage condition violated." + --#SUMMARY "Undervoltage condition violated." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 646 + +atsRMSUnderVoltageCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Undervoltage condition cleared. + The first argument is the serial number. + The second argument is the product name. + The third argument is an integer representing the source: 0=A, 1=B." + --#TYPE "APC ATS: Undervoltage condition cleared." + --#SUMMARY "Undervoltage condition cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 647 + +atsRMSOverFrequency TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: OverFrequency condition violated. + The first argument is the serial number. + The second argument is the product name. + The third argument is an integer representing the source: 0=A, 1=B." + --#TYPE "APC ATS: OverFrequency condition violated." + --#SUMMARY "OverFrequency condition violated." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 648 + +atsRMSOverFrequencyCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: OverFrequency condition cleared. + The first argument is the serial number. + The second argument is the product name. + The third argument is an integer representing the source: 0=A, 1=B." + --#TYPE "APC ATS: OverFrequency condition cleared." + --#SUMMARY "OverFrequency condition cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 649 + +atsRMSUnderFrequency TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: UnderFrequency condition violated. + The first argument is the serial number. + The second argument is the product name. + The third argument is an integer representing the source: 0=A, 1=B." + --#TYPE "APC ATS: UnderFrequency condition violated." + --#SUMMARY "UnderFrequency condition violated." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 650 + +atsRMSUnderFrequencyCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: UnderFrequency condition cleared. + The first argument is the serial number. + The second argument is the product name. + The third argument is an integer representing the source: 0=A, 1=B." + --#TYPE "APC ATS: UnderFrequency condition cleared." + --#SUMMARY "UnderFrequency condition cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 651 + + + +-- MODULAR POWER DISTRIBUTION SYSTEM + +isxModularDistributionCommLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: Communication with a metering segment of the modular + distribution system has been lost. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the segment number. + The fourth argument describes the modules served by this metering segment." + --#TYPE "APC MDS: Com lost in modular distribution system." + --#SUMMARY "Modular distribution communication lost." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 652 + +isxModularDistributionCommEstablished TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Communication with a metering segment of the modular + distribution system has been restored. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the segment number. + The fourth argument describes the modules served by this metering segment." + --#TYPE "APC MDS: Com restored in modular distribution system." + --#SUMMARY "Modular distribution communication restored." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 653 + +isxModularDistributionModuleInserted TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A distribution module has been inserted into the system. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the module location number." + --#TYPE "APC MDS: Distribution module inserted." + --#SUMMARY "Distribution module inserted." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 654 + +isxModularDistributionModuleRemoved TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A distribution module has been removed from the system. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the module location number." + --#TYPE "APC MDS: Distribution module removed." + --#SUMMARY "Distribution module removed." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 655 + +isxModularBreakerOpenAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: A distribution module breaker is open and in an alarm condition. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the module number. + The fourth argument is the module breaker(s) (1=L1, 2=L2, 3=L3, 4=L12, 5=L23, 6=L123). + The fifth argument is the load name associated with the circuit/cable fed by this breaker." + --#TYPE "APC MDS: Distribution breaker open alarm." + --#SUMMARY "Distribution breaker open alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 656 + +isxModularBreakerOpenAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An alarm caused by a distribution breaker being open has been cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the module number. + The fourth argument is the breaker(s) (1=L1, 2=L2, 3=L3, 4=L12, 5=L23, 6=L123). + The fifth argument is the load name associated with the circuit/cable fed by this breaker." + --#TYPE "APC MDS: Distribution breaker open alarm cleared." + --#SUMMARY "Distribution breaker open alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 657 + +isxModularMinCurrentThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsInteger02, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: The current in a distribution module is below the minimum/critical + limit specified for the circuit/cable. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the module number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. + The sixth argument is the load name associated with the circuit/cable fed by this breaker." + --#TYPE "APC MDS: Distribution minimum current alarm." + --#SUMMARY "Distribution current is below the critical threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 658 + +isxModularMinCurrentThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The current in a distribution module is no longer below the minimum/critical + limit specified for the circuit/cable. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the module number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the load name associated with the circuit/cable fed by this breaker." + --#TYPE "APC MDS: Distribution minimum current alarm cleared." + --#SUMMARY "Distribution current no longer below the critical threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 659 + +isxModularLowCurrentThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsInteger02, mtrapargsString04, mtrapargsString } + DESCRIPTION + "WARNING: The current in a distribution module is below the low/warning + limit specified for the circuit/cable. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the module number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. + The sixth argument is the load name associated with the circuit/cable fed by this breaker." + --#TYPE "APC MDS: Distribution low current alarm." + --#SUMMARY "Distribution current is below the warning threshold." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 660 + +isxModularLowCurrentThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The current in a distribution module is no longer below the low/warning + limit specified for the circuit/cable. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the module number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the load name associated with the circuit/cable fed by this breaker." + --#TYPE "APC MDS: Distribution low current alarm cleared." + --#SUMMARY "Distribution current no longer below the warning threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 661 + +isxModularHighCurrentThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsInteger02, mtrapargsString04, mtrapargsString } + DESCRIPTION + "WARNING: The current in a distribution module is above the high/warning + limit specified for the circuit/cable. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the module number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. + The sixth argument is the load name associated with the circuit/cable fed by this breaker." + --#TYPE "APC MDS: Distribution high current alarm." + --#SUMMARY "Distribution current is above the warning threshold." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 662 + +isxModularHighCurrentThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The current in a distribution module is no longer above the high/warning + limit specified for the circuit/cable. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the module number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the load name associated with the circuit/cable fed by this breaker." + --#TYPE "APC MDS: Distribution high current alarm cleared." + --#SUMMARY "Distribution current no longer above the warning threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 663 + +isxModularMaxCurrentThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsInteger02, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: The current in a distribution module is above the maximum/critical + limit specified for the circuit/cable. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the module number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. + The sixth argument is the load name associated with the circuit/cable fed by this breaker." + --#TYPE "APC MDS: Distribution maximum current alarm." + --#SUMMARY "Distribution current is above the critical threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 664 + +isxModularMaxCurrentThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The current in a distribution module is no longer above the maximum/critical + limit specified for the circuit/cable. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the module number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the load name associated with the circuit/cable fed by this breaker." + --#TYPE "APC MDS: Distribution maximum current alarm cleared." + --#SUMMARY "Distribution current no longer above the critical threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 665 + +isxModularSubfeedBreakerOpenAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: A distribution subfeed breaker is open and in an alarm condition. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the subfeed number. + The fourth argument is the load name associated with the subfeed." + --#TYPE "APC MDS: Distribution subfeed breaker open alarm." + --#SUMMARY "Distribution subfeed breaker open alarm." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 666 + +isxModularSubfeedBreakerOpenAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An alarm caused by a distribution subfeed breaker being open has been cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the subfeed number. + The fourth argument is the load name associated with the subfeed." + --#TYPE "APC MDS: Distribution subfeed breaker open alarm cleared." + --#SUMMARY "Distribution subfeed breaker open alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 667 + +isxModularSubfeedMinCurrentThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsInteger02, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: The current in a distribution subfeed is below the minimum/critical limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the subfeed number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. + The sixth argument is the load name associated with the subfeed." + --#TYPE "APC MDS: Distribution subfeed minimum current alarm." + --#SUMMARY "Distribution subfeed current is below the critical threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 668 + +isxModularSubfeedMinCurrentThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The current in a distribution subfeed is no longer below the minimum/critical limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the subfeed number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the load name associated with the subfeed." + --#TYPE "APC MDS: Distribution subfeed minimum current alarm cleared." + --#SUMMARY "Distribution subfeed current no longer below the critical threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 669 + +isxModularSubfeedLowCurrentThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsInteger02, mtrapargsString04, mtrapargsString } + DESCRIPTION + "WARNING: The current in a distribution subfeed is below the low/warning limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the subfeed number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. + The sixth argument is the load name associated with the subfeed." + --#TYPE "APC MDS: Distribution subfeed low current alarm." + --#SUMMARY "Distribution subfeed current is below the warning threshold." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 670 + +isxModularSubfeedLowCurrentThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The current in a distribution subfeed is no longer below the low/warning limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the subfeed number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the load name associated with the subfeed." + --#TYPE "APC MDS: Distribution subfeed low current alarm cleared." + --#SUMMARY "Distribution subfeed current is no longer below the warning threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 671 + +isxModularSubfeedHighCurrentThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsInteger02, mtrapargsString04, mtrapargsString } + DESCRIPTION + "WARNING: The current in a distribution subfeed is above the high/warning limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the subfeed number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. + The sixth argument is the load name associated with the subfeed." + --#TYPE "APC MDS: Distribution subfeed high current alarm." + --#SUMMARY "Distribution subfeed current is above the warning threshold." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 672 + +isxModularSubfeedHighCurrentThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The current in a distribution subfeed is no longer above the high/warning limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the subfeed number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the load name associated with the subfeed." + --#TYPE "APC MDS: Distribution subfeed high current alarm cleared." + --#SUMMARY "Distribution subfeed current no longer above the warning threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 673 + +isxModularSubfeedMaxCurrentThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsInteger02, mtrapargsString04, mtrapargsString } + DESCRIPTION + "SEVERE: The current in a distribution subfeed is above the maximum/critical limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the subfeed number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. + The sixth argument is the load name associated with the subfeed." + --#TYPE "APC MDS: Distribution subfeed maximum current alarm." + --#SUMMARY "Distribution subfeed current is above the critical threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 674 + +isxModularSubfeedMaxCurrentThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03, + mtrapargsString04, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The current in a distribution subfeed is no longer above the maximum/critical limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the subfeed number. + The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). + The fifth argument is the load name associated with the subfeed." + --#TYPE "APC MDS: Distribution subfeed maximum current alarm cleared." + --#SUMMARY "Distribution subfeed current no longer above the critical threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 675 + +isxModularTotalOutputCurrentMinThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: The total output current of the distribution is below the minimum/critical limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3). + The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated." + --#TYPE "APC MDS: Total distribution output minimum current alarm." + --#SUMMARY "Distribution total current is below the critical threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 676 + +isxModularTotalOutputCurrentMinThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The total output current of the distribution is no longer below the minimum/critical limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3)." + --#TYPE "APC MDS: Total output minimum current alarm cleared." + --#SUMMARY "Distribution total current no longer below the critical threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 677 + +isxModularTotalOutputCurrentLowThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "WARNING: The total output current of the distribution is below the low/warning limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3). + The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated." + --#TYPE "APC MDS: Total output low current alarm." + --#SUMMARY "Distribution total current is below the warning threshold." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 678 + +isxModularTotalOutputCurrentLowThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The total output current of the distribution is no longer below the low/warning limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3)." + --#TYPE "APC MDS: Total output low current alarm cleared." + --#SUMMARY "Distribution total current no longer below the warning threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 679 + +isxModularTotalOutputCurrentHighThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "WARNING: The total output current of the distribution is above the high/warning limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3). + The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated." + --#TYPE "APC MDS: Total output high current alarm." + --#SUMMARY "Distribution total current is above the warning threshold." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 680 + +isxModularTotalOutputCurrentHighThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The total output current of the distribution is no longer above the high/warning limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3)." + --#TYPE "APC MDS: Total output high current alarm cleared." + --#SUMMARY "Distribution total current no longer above the warning threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 681 + +isxModularTotalOutputCurrentMaxThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: The total output current of the distribution is above the maximum/critical limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3). + The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated." + --#TYPE "APC MDS: Total output maximum current alarm." + --#SUMMARY "Distribution total current is above the critical threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 682 + +isxModularTotalOutputCurrentMaxThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The total output current of the distribution is no longer above the maximum/critical limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3)." + --#TYPE "APC MDS: Total output maximum current alarm cleared." + --#SUMMARY "Distribution total current no longer above the critical threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 683 + +isxModularOutputVoltageMinThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: The distribution output voltage is below the minimum/critical limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3). + The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated." + --#TYPE "APC MDS: Distribution minimum output voltage alarm." + --#SUMMARY "Distribution output voltage is below the critical threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 684 + +isxModularOutputVoltageMinThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The distribution output voltage is no longer below the minimum/critical limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3)." + --#TYPE "APC MDS: Distribution minimum output voltage alarm cleared." + --#SUMMARY "Distribution output voltage no longer below the critical threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 685 + +isxModularOutputVoltageLowThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "WARNING: The distribution output voltage is below the low/warning limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3). + The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated." + --#TYPE "APC MDS: Distribution low output voltage alarm." + --#SUMMARY "Distribution output voltage is below the warning threshold." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 686 + +isxModularOutputVoltageLowThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The distribution output voltage is no longer below the low/warning limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3)." + --#TYPE "APC MDS: Distribution low output voltage alarm cleared." + --#SUMMARY "Distribution output voltage no longer below the warning threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 687 + +isxModularOutputVoltageHighThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "WARNING: The distribution output voltage is above the high/warning limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3). + The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated." + --#TYPE "APC MDS: Distribution high output voltage alarm." + --#SUMMARY "Distribution output voltage is above the warning threshold." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 688 + +isxModularOutputVoltageHighThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The distribution output voltage is no longer above the high/warning limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3)." + --#TYPE "APC MDS: Distribution high output voltage alarm cleared." + --#SUMMARY "Distribution output voltage no longer above the warning threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 689 + +isxModularOutputVoltageMaxThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: The distribution output voltage is above the maximum/critical limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3). + The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated." + --#TYPE "APC MDS: Distribution maximum output voltage alarm." + --#SUMMARY "Distribution output voltage is above the critical threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 690 + +isxModularOutputVoltageMaxThresholdViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, + mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The distribution output voltage is no longer above the maximum/critical limit specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the phase index (1=L1, 2=L2, 3=L3)." + --#TYPE "APC MDS: Distribution maximum output voltage alarm cleared." + --#SUMMARY "Distribution output voltage no longer above the critical threshold." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 691 + +apcDoorClosedImproperly TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "SEVERE: A door has been closed improperly. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: Door closed improperly." + --#SUMMARY "Door closed improperly." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 692 + +apcDoorClosedImproperlyCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: A door is no longer closed improperly. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: Door no longer closed improperly." + --#SUMMARY "Door no longer closed improperly." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 693 + +apcUserScheduleViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "SEVERE: A user has had a door opened past the scheduled access period. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: User schedule violated." + --#SUMMARY "User schedule violated." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 694 + +apcUserScheduleViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, + mtrapargsString04, mtrapargsInteger, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: User schedule violation has been cleared. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the host device location. + The fourth argument is the door identifier, (1=front, 2=rear)." + --#TYPE "APC: User schedule violation cleared." + --#SUMMARY "User schedule violation cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 695 + +isxModularOutputFrequencyThresholdViolation TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: The distribution output frequency is outside of the operating range specified. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the threshold, in tenths of Hertz, from which the alarm was generated." + --#TYPE "APC MDS: Distribution output frequency out of range." + --#SUMMARY "Distribution output frequency out of range." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 696 + +isxModularOutputFrequencyViolationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The distribution output frequency is no longer out of range. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC MDS: Distribution output frequency no longer out of range." + --#SUMMARY "Distribution output frequency no longer out of range." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 697 + +atsSourceStatusFail TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: ATS Source failed. + The first argument is the serial number. + The second argument is the product name. + The third argument is an integer representing the source: 0=A, 1=B." + --#TYPE "APC ATS: ATS Source failed." + --#SUMMARY "ATS Source failed." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 698 + +atsSourceStatusOk TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: ATS Source OK. + The first argument is the serial number. + The second argument is the product name. + The third argument is an integer representing the source: 0=A, 1=B." + --#TYPE "APC ATS: ATS Source OK." + --#SUMMARY "ATS Source OK." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 699 + +atsHardwareStatusFail TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: ATS display board hardware failed. + The first argument is the serial number. + The second argument is the product name. + The third argument is an integer representing the failed hardware: + 0= Phase LEDs/Push-button hardware failure + 1= Seven-segment display hardware failure." + --#TYPE "APC ATS: ATS display board hardware failed." + --#SUMMARY "ATS display board hardware failed." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 700 + +atsHardwareStatusOk TRAP-TYPE + ENTERPRISE apc + VARIABLES { atsIdentSerialNumber, atsConfigProductName, + mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: ATS display board hardware ok. + The first argument is the serial number. + The second argument is the product name. + The third argument is an integer representing the hardware: + 0= Phase LEDs/Push-button hardware failure + 1= Seven-segment display hardware failure." + --#TYPE "APC ATS: ATS display board hardware ok." + --#SUMMARY "ATS display board hardware ok." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 701 + +atsControllerRestart TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: ATS Controller restarted." + --#TYPE "APC ATS: ATS Controller restarted." + --#SUMMARY "ATS Controller restarted." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 702 + + + + +xATSS1BadPhaseRotation TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString } + DESCRIPTION + "SEVERE: The device's source 1 phase rotation is bad. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: S1 bad phase rotation alarm." + --#SUMMARY "Phase rotation on source 1 is bad." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 724 + +xATSS1BadPhaseRotationCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: The device's source 1 phase rotation is back to normal. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: S1 phase rotation back to normal." + --#SUMMARY "S1 phase rotation back to normal." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 725 + +xATSS1BadPhaseBalance TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, + mtrapargsString} + DESCRIPTION + "SEVERE: The device's source 1 phase balance is out of bounds. + The first argument is the host device serial number. + The second argument is the host device name. + The third argument is the minimum phase balance as a percentage." + --#TYPE "APC XATS: S1 phase imbalance exceeds threshold alarm." + --#SUMMARY "Phase imbalance on source 1 exceeds threshold." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 726 + +xATSS1BadPhaseBalanceCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString} + DESCRIPTION + "INFORMATIONAL: The device's source 1 phase balance is back to normal. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC XATS: S1 phase balance back to normal." + --#SUMMARY "S1 phase balance back to normal." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 727 + +isxModularTransformerOverheating TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString } + DESCRIPTION + "SEVERE: The distribution transformer temperature is too hot. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC MDS: Transformer overheating." + --#SUMMARY "Distribution transformer temperature is too hot." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 728 + +isxModularTransformerOverheatingCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The distribution transformer temperature has returned to normal. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC MDS: Transformer temperature has returned to normal." + --#SUMMARY "Distribution transformer temperature has returned to normal." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 729 + +apcInternalCommunicationFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: An internal UPS communication fault exists." + --#TYPE "APC Device: An internal UPS communication fault exists." + --#SUMMARY "An internal UPS communication fault exists." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 730 + +apcInternalCommunicationFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An internal UPS communication fault no longer exists." + --#TYPE "APC Device:An internal UPS communication fault no longer exists." + --#SUMMARY "An internal UPS communication fault no longer exists." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 731 + +upsOutletGroupCommand TRAP-TYPE + ENTERPRISE apc + VARIABLES { upsOutletGroupControlIndex, mtrapargsString } + DESCRIPTION + "WARNING: The specified Outlet Group command has been issued." + --#TYPE "APC UPS: Outlet Group command issued." + --#SUMMARY "Outlet Group command issued." + --#ARGUMENTS { } + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 732 + +onbatterycommunicationLost TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: Communication to the UPS when the UPS is on Battery. Steps + to reestablish communication are in progress." + --#TYPE "APC UPS: Communication lost" + --#SUMMARY "Communication lost between the agent and the UPS when UPS is on Battery." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 733 + +upsCriticalCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "SEVERE: A UPS critical condition was detected. + The first variable is the error condition text message. + The second variable is the error number." + --#TYPE "UPS: A critical condition has been detected." + --#SUMMARY "A critical condition has been detected." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 734 + +upsCriticalConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A UPS critical condition has been cleared. + The first variable is the fault condition." + --#TYPE "UPS: A critical condition has been cleared." + --#SUMMARY "A critical condition has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 735 + +upsWarningCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: A UPS warning condition has been detected. + The first variable is the fault condition." + --#TYPE "UPS: A warning condition has been detected." + --#SUMMARY "A warning condition has been detected." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 736 + +upsWarningConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "WARNING: A UPS warning condition has been cleared. + The first variable is the fault condition." + --#TYPE "UPS: A warning condition has been cleared." + --#SUMMARY "A warning condition has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 737 + +upsInformationalCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A UPS informational condition has been detected. + The first variable is the fault condition." + --#TYPE "UPS: Informational condition detected." + --#SUMMARY "An informational condition has been detected." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 738 + +upsInformationalConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A UPS informational condition has been cleared. + The first variable is the fault condition." + --#TYPE "UPS: Informational condition cleared." + --#SUMMARY "An informational condition has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 739 + +isxcInformationalAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, + mtrapargsOctetString, + mtrapargsInteger, + mtrapargsString03, + mtrapargsOctetString02, + mtrapargsString04, + mtrapargsOctetString03, + mtrapargsString05, + mtrapargsString06, + mtrapargsString07, + mtrapargsOctetString04, + mtrapargsOctetString05, + mtrapargsString08, + mtrapargsOctetString06, + mtrapargsOctetString07, + mtrapargsInteger02, + mtrapargsInteger03, + mtrapargsOctetString08, + mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An ISXC Alarm exists. + The first argument is the unique ISXC alarm ID. + The second argument is the ISXC alarm label as a UTF8 string. + The third argument is the ISXC alarm code. + The fourth argument is the unique ISXC device ID. + The fifth argument is the ISXC device label as a UTF8 string. + The sixth argument is the ISXC parent host. + The seventh argument is the ISXC device type as a UTF8 string. + The eighth argument is the device serial number. + The ninth argument is the device model number. + The tenth argument is the device host. + The eleventh argument is the device location as a UTF8 string. + The twelfth argument is the device contact as a UTF8 string. + The thirteenth argument is the unique ISXC sensor ID. + The fourteenth argument is the ISXC sensor label as a UTF8 string. + The fifteenth argument is the sensor value as a UTF8 string. + The sixteenth argument is the ISXC alarm start time. + The seventeenth argument is the ISXC alarm resolution time. + The eighteenth argument is the description as a UTF8 string." + --#TYPE "APC ISXC: An ISXC Informational Alarm exists." + --#SUMMARY "An ISXC Informational Alarm exists." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 740 + +isxcInformationalAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, + mtrapargsOctetString, + mtrapargsInteger, + mtrapargsString03, + mtrapargsOctetString02, + mtrapargsString04, + mtrapargsOctetString03, + mtrapargsString05, + mtrapargsString06, + mtrapargsString07, + mtrapargsOctetString04, + mtrapargsOctetString05, + mtrapargsString08, + mtrapargsOctetString06, + mtrapargsOctetString07, + mtrapargsInteger02, + mtrapargsInteger03, + mtrapargsOctetString08, + mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An ISXC Alarm has been cleared. + The first argument is the unique ISXC alarm ID. + The second argument is the ISXC alarm label as a UTF8 string. + The third argument is the ISXC alarm code. + The fourth argument is the unique ISXC device ID. + The fifth argument is the ISXC device label as a UTF8 string. + The sixth argument is the ISXC parent host. + The seventh argument is the ISXC device type as a UTF8 string. + The eighth argument is the device serial number. + The ninth argument is the device model number. + The tenth argument is the device host. + The eleventh argument is the device location as a UTF8 string. + The twelfth argument is the device contact as a UTF8 string. + The thirteenth argument is the unique ISXC sensor ID. + The fourteenth argument is the ISXC sensor label as a UTF8 string. + The fifteenth argument is the sensor value as a UTF8 string. + The sixteenth argument is the ISXC alarm start time. + The seventeenth argument is the ISXC alarm resolution time. + The eighteenth argument is the description as a UTF8 string." + --#TYPE "APC ISXC: An ISXC Informational Alarm has been cleared." + --#SUMMARY "An ISXC Informational Alarm has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 741 + +isxcWarningAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, + mtrapargsOctetString, + mtrapargsInteger, + mtrapargsString03, + mtrapargsOctetString02, + mtrapargsString04, + mtrapargsOctetString03, + mtrapargsString05, + mtrapargsString06, + mtrapargsString07, + mtrapargsOctetString04, + mtrapargsOctetString05, + mtrapargsString08, + mtrapargsOctetString06, + mtrapargsOctetString07, + mtrapargsInteger02, + mtrapargsInteger03, + mtrapargsOctetString08, + mtrapargsString } + DESCRIPTION + "WARNING: An ISXC Alarm exists. + The first argument is the unique ISXC alarm ID. + The second argument is the ISXC alarm label as a UTF8 string. + The third argument is the ISXC alarm code. + The fourth argument is the unique ISXC device ID. + The fifth argument is the ISXC device label as a UTF8 string. + The sixth argument is the ISXC parent host. + The seventh argument is the ISXC device type as a UTF8 string. + The eighth argument is the device serial number. + The ninth argument is the device model number. + The tenth argument is the device host. + The eleventh argument is the device location as a UTF8 string. + The twelfth argument is the device contact as a UTF8 string. + The thirteenth argument is the unique ISXC sensor ID. + The fourteenth argument is the ISXC sensor label as a UTF8 string. + The fifteenth argument is the sensor value as a UTF8 string. + The sixteenth argument is the ISXC alarm start time. + The seventeenth argument is the ISXC alarm resolution time. + The eighteenth argument is the description as a UTF8 string." + --#TYPE "APC ISXC: An ISXC Warning Alarm exists." + --#SUMMARY "An ISXC Warning Alarm exists." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 742 + +isxcWarningAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, + mtrapargsOctetString, + mtrapargsInteger, + mtrapargsString03, + mtrapargsOctetString02, + mtrapargsString04, + mtrapargsOctetString03, + mtrapargsString05, + mtrapargsString06, + mtrapargsString07, + mtrapargsOctetString04, + mtrapargsOctetString05, + mtrapargsString08, + mtrapargsOctetString06, + mtrapargsOctetString07, + mtrapargsInteger02, + mtrapargsInteger03, + mtrapargsOctetString08, + mtrapargsString } + DESCRIPTION + "WARNING: An ISXC Alarm has been cleared. + The first argument is the unique ISXC alarm ID. + The second argument is the ISXC alarm label as a UTF8 string. + The third argument is the ISXC alarm code. + The fourth argument is the unique ISXC device ID. + The fifth argument is the ISXC device label as a UTF8 string. + The sixth argument is the ISXC parent host. + The seventh argument is the ISXC device type as a UTF8 string. + The eighth argument is the device serial number. + The ninth argument is the device model number. + The tenth argument is the device host. + The eleventh argument is the device location as a UTF8 string. + The twelfth argument is the device contact as a UTF8 string. + The thirteenth argument is the unique ISXC sensor ID. + The fourteenth argument is the ISXC sensor label as a UTF8 string. + The fifteenth argument is the sensor value as a UTF8 string. + The sixteenth argument is the ISXC alarm start time. + The seventeenth argument is the ISXC alarm resolution time. + The eighteenth argument is the description as a UTF8 string." + --#TYPE "APC ISXC: An ISXC Warning Alarm has been cleared." + --#SUMMARY "An ISXC Warning Alarm has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 743 + +isxcErrorAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, + mtrapargsOctetString, + mtrapargsInteger, + mtrapargsString03, + mtrapargsOctetString02, + mtrapargsString04, + mtrapargsOctetString03, + mtrapargsString05, + mtrapargsString06, + mtrapargsString07, + mtrapargsOctetString04, + mtrapargsOctetString05, + mtrapargsString08, + mtrapargsOctetString06, + mtrapargsOctetString07, + mtrapargsInteger02, + mtrapargsInteger03, + mtrapargsOctetString08, + mtrapargsString } + DESCRIPTION + "ERROR: An ISXC Alarm exists. + The first argument is the unique ISXC alarm ID. + The second argument is the ISXC alarm label as a UTF8 string. + The third argument is the ISXC alarm code. + The fourth argument is the unique ISXC device ID. + The fifth argument is the ISXC device label as a UTF8 string. + The sixth argument is the ISXC parent host. + The seventh argument is the ISXC device type as a UTF8 string. + The eighth argument is the device serial number. + The ninth argument is the device model number. + The tenth argument is the device host. + The eleventh argument is the device location as a UTF8 string. + The twelfth argument is the device contact as a UTF8 string. + The thirteenth argument is the unique ISXC sensor ID. + The fourteenth argument is the ISXC sensor label as a UTF8 string. + The fifteenth argument is the sensor value as a UTF8 string. + The sixteenth argument is the ISXC alarm start time. + The seventeenth argument is the ISXC alarm resolution time. + The eighteenth argument is the description as a UTF8 string." + --#TYPE "APC ISXC: An ISXC Error Alarm exists." + --#SUMMARY "An ISXC Error Alarm exists." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 744 + +isxcErrorAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, + mtrapargsOctetString, + mtrapargsInteger, + mtrapargsString03, + mtrapargsOctetString02, + mtrapargsString04, + mtrapargsOctetString03, + mtrapargsString05, + mtrapargsString06, + mtrapargsString07, + mtrapargsOctetString04, + mtrapargsOctetString05, + mtrapargsString08, + mtrapargsOctetString06, + mtrapargsOctetString07, + mtrapargsInteger02, + mtrapargsInteger03, + mtrapargsOctetString08, + mtrapargsString } + DESCRIPTION + "ERROR: An ISXC Alarm has been cleared. + The first argument is the unique ISXC alarm ID. + The second argument is the ISXC alarm label as a UTF8 string. + The third argument is the ISXC alarm code. + The fourth argument is the unique ISXC device ID. + The fifth argument is the ISXC device label as a UTF8 string. + The sixth argument is the ISXC parent host. + The seventh argument is the ISXC device type as a UTF8 string. + The eighth argument is the device serial number. + The ninth argument is the device model number. + The tenth argument is the device host. + The eleventh argument is the device location as a UTF8 string. + The twelfth argument is the device contact as a UTF8 string. + The thirteenth argument is the unique ISXC sensor ID. + The fourteenth argument is the ISXC sensor label as a UTF8 string. + The fifteenth argument is the sensor value as a UTF8 string. + The sixteenth argument is the ISXC alarm start time. + The seventeenth argument is the ISXC alarm resolution time. + The eighteenth argument is the description as a UTF8 string." + --#TYPE "APC ISXC: An ISXC Error Alarm has been cleared." + --#SUMMARY "An ISXC Error Alarm has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 745 + +isxcCriticalAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, + mtrapargsOctetString, + mtrapargsInteger, + mtrapargsString03, + mtrapargsOctetString02, + mtrapargsString04, + mtrapargsOctetString03, + mtrapargsString05, + mtrapargsString06, + mtrapargsString07, + mtrapargsOctetString04, + mtrapargsOctetString05, + mtrapargsString08, + mtrapargsOctetString06, + mtrapargsOctetString07, + mtrapargsInteger02, + mtrapargsInteger03, + mtrapargsOctetString08, + mtrapargsString } + DESCRIPTION + "CRITICAL: An ISXC Alarm exists. + The first argument is the unique ISXC alarm ID. + The second argument is the ISXC alarm label as a UTF8 string. + The third argument is the ISXC alarm code. + The fourth argument is the unique ISXC device ID. + The fifth argument is the ISXC device label as a UTF8 string. + The sixth argument is the ISXC parent host. + The seventh argument is the ISXC device type as a UTF8 string. + The eighth argument is the device serial number. + The ninth argument is the device model number. + The tenth argument is the device host. + The eleventh argument is the device location as a UTF8 string. + The twelfth argument is the device contact as a UTF8 string. + The thirteenth argument is the unique ISXC sensor ID. + The fourteenth argument is the ISXC sensor label as a UTF8 string. + The fifteenth argument is the sensor value as a UTF8 string. + The sixteenth argument is the ISXC alarm start time. + The seventeenth argument is the ISXC alarm resolution time. + The eighteenth argument is the description as a UTF8 string." + --#TYPE "APC ISXC: An ISXC Critical Alarm exists." + --#SUMMARY "An ISXC Critical Alarm exists." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 746 + +isxcCriticalAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, + mtrapargsOctetString, + mtrapargsInteger, + mtrapargsString03, + mtrapargsOctetString02, + mtrapargsString04, + mtrapargsOctetString03, + mtrapargsString05, + mtrapargsString06, + mtrapargsString07, + mtrapargsOctetString04, + mtrapargsOctetString05, + mtrapargsString08, + mtrapargsOctetString06, + mtrapargsOctetString07, + mtrapargsInteger02, + mtrapargsInteger03, + mtrapargsOctetString08, + mtrapargsString } + DESCRIPTION + "CRITICAL: An ISXC Alarm has been cleared. + The first argument is the unique ISXC alarm ID. + The second argument is the ISXC alarm label as a UTF8 string. + The third argument is the ISXC alarm code. + The fourth argument is the unique ISXC device ID. + The fifth argument is the ISXC device label as a UTF8 string. + The sixth argument is the ISXC parent host. + The seventh argument is the ISXC device type as a UTF8 string. + The eighth argument is the device serial number. + The ninth argument is the device model number. + The tenth argument is the device host. + The eleventh argument is the device location as a UTF8 string. + The twelfth argument is the device contact as a UTF8 string. + The thirteenth argument is the unique ISXC sensor ID. + The fourteenth argument is the ISXC sensor label as a UTF8 string. + The fifteenth argument is the sensor value as a UTF8 string. + The sixteenth argument is the ISXC alarm start time. + The seventeenth argument is the ISXC alarm resolution time. + The eighteenth argument is the description as a UTF8 string." + --#TYPE "APC ISXC: An ISXC Critical Alarm has been cleared." + --#SUMMARY "An ISXC Critical Alarm has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 747 + +isxcFailureAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, + mtrapargsOctetString, + mtrapargsInteger, + mtrapargsString03, + mtrapargsOctetString02, + mtrapargsString04, + mtrapargsOctetString03, + mtrapargsString05, + mtrapargsString06, + mtrapargsString07, + mtrapargsOctetString04, + mtrapargsOctetString05, + mtrapargsString08, + mtrapargsOctetString06, + mtrapargsOctetString07, + mtrapargsInteger02, + mtrapargsInteger03, + mtrapargsOctetString08, + mtrapargsString } + DESCRIPTION + "FAILURE: An ISXC Alarm exists. + The first argument is the unique ISXC alarm ID. + The second argument is the ISXC alarm label as a UTF8 string. + The third argument is the ISXC alarm code. + The fourth argument is the unique ISXC device ID. + The fifth argument is the ISXC device label as a UTF8 string. + The sixth argument is the ISXC parent host. + The seventh argument is the ISXC device type as a UTF8 string. + The eighth argument is the device serial number. + The ninth argument is the device model number. + The tenth argument is the device host. + The eleventh argument is the device location as a UTF8 string. + The twelfth argument is the device contact as a UTF8 string. + The thirteenth argument is the unique ISXC sensor ID. + The fourteenth argument is the ISXC sensor label as a UTF8 string. + The fifteenth argument is the sensor value as a UTF8 string. + The sixteenth argument is the ISXC alarm start time. + The seventeenth argument is the ISXC alarm resolution time. + The eighteenth argument is the description as a UTF8 string." + --#TYPE "APC ISXC: An ISXC Failure Alarm exists." + --#SUMMARY "An ISXC Failure Alarm exists." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 748 + +isxcFailureAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, + mtrapargsOctetString, + mtrapargsInteger, + mtrapargsString03, + mtrapargsOctetString02, + mtrapargsString04, + mtrapargsOctetString03, + mtrapargsString05, + mtrapargsString06, + mtrapargsString07, + mtrapargsOctetString04, + mtrapargsOctetString05, + mtrapargsString08, + mtrapargsOctetString06, + mtrapargsOctetString07, + mtrapargsInteger02, + mtrapargsInteger03, + mtrapargsOctetString08, + mtrapargsString } + DESCRIPTION + "FAILURE: An ISXC Alarm has been cleared. + The first argument is the unique ISXC alarm ID. + The second argument is the ISXC alarm label as a UTF8 string. + The third argument is the ISXC alarm code. + The fourth argument is the unique ISXC device ID. + The fifth argument is the ISXC device label as a UTF8 string. + The sixth argument is the ISXC parent host. + The seventh argument is the ISXC device type as a UTF8 string. + The eighth argument is the device serial number. + The ninth argument is the device model number. + The tenth argument is the device host. + The eleventh argument is the device location as a UTF8 string. + The twelfth argument is the device contact as a UTF8 string. + The thirteenth argument is the unique ISXC sensor ID. + The fourteenth argument is the ISXC sensor label as a UTF8 string. + The fifteenth argument is the sensor value as a UTF8 string. + The sixteenth argument is the ISXC alarm start time. + The seventeenth argument is the ISXC alarm resolution time. + The eighteenth argument is the description as a UTF8 string." + --#TYPE "APC ISXC: An ISXC Failure Alarm has been cleared." + --#SUMMARY "An ISXC Failure Alarm has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 749 + +-- rPDU2g Trap Section + +rpduCriticalCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "SEVERE: A RPDU critical condition has been detected. + The first variable is the serial number. + The second variable is the device name. + The third variable is the error number. + The fourth variable is the device number. + The fifth variable is the instance number. + The sixth variable is the trap text message." + --#TYPE "RPDU: A critical condition has been detected." + --#SUMMARY "A critical condition has been detected." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 750 + +rpduCriticalConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A RPDU critical condition has been cleared. + The first variable is the serial number. + The second variable is the device name. + The third variable is the error number. + The fourth variable is the device number. + The fifth variable is the instance number. + The sixth variable is the trap text message." + --#TYPE "RPDU: A critical condition has been cleared." + --#SUMMARY "A critical condition has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 751 + +rpduWarningCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "WARNING: A RPDU warning condition has been detected. + The first variable is the serial number. + The second variable is the device name. + The third variable is the error number. + The fourth variable is the device number. + The fifth variable is the instance number. + The sixth variable is the trap text message." + --#TYPE "RPDU: A warning condition has been detected." + --#SUMMARY "A warning condition has been detected." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 752 + +rpduWarningConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "WARNING: A RPDU warning condition has been cleared. + The first variable is the serial number. + The second variable is the device name. + The third variable is the error number. + The fourth variable is the device number. + The fifth variable is the instance number. + The sixth variable is the trap text message." + --#TYPE "RPDU: A warning condition has been cleared." + --#SUMMARY "A warning condition has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 753 + +rpduInformationalCondition TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A RPDU informational condition has been detected. + The first variable is the serial number. + The second variable is the device name. + The third variable is the error number. + The fourth variable is the device number. + The fifth variable is the instance number. + The sixth variable is the trap text message." + --#TYPE "RPDU: Informational condition detected." + --#SUMMARY "An informational condition has been detected." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 754 + +rpduInformationalConditionCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A RPDU informational condition has been cleared. + The first variable is the serial number. + The second variable is the device name. + The third variable is the error number. + The fourth variable is the device number. + The fifth variable is the instance number. + The sixth variable is the trap text message." + --#TYPE "RPDU: Informational condition cleared." + --#SUMMARY "An informational condition has been cleared." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 755 + +isxModularCoolingFanAlarm TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString } + DESCRIPTION + "SEVERE: The device's internal cooling fans have failed. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC MDS: Cooling fan failure." + --#SUMMARY "Cooling fan failure." + --#ARGUMENTS { } + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 756 + +isxModularCoolingFanAlarmCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString } + DESCRIPTION + "INFORMATIONAL: The device's internal cooling fans are now functioning properly. + The first argument is the host device serial number. + The second argument is the host device name." + --#TYPE "APC MDS: Cooling fan alarm cleared." + --#SUMMARY "Cooling fan alarm cleared." + --#ARGUMENTS { } + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 757 + +upsFirmwareUpdateStarted TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: Updating UPS firmware." + --#TYPE "APC UPS: Updating firmware" + --#SUMMARY "The UPS has started a firmware update." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 758 + +upsFirmwareUpdateFinished TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Finished updating UPS firmware." + --#TYPE "APC UPS: Finished firmware update" + --#SUMMARY "The UPS has finished the firmware update." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 759 + +upsFirmwareUpdateSucceeded TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: UPS firmware update succeeded." + --#TYPE "APC UPS: Firmware update succeeded" + --#SUMMARY "The UPS has successfully completed a firmware update." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 760 + +upsFirmwareUpdateFailed TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: UPS firmware update failed." + --#TYPE "APC UPS: Firmware update failed" + --#SUMMARY "The UPS failed to complete a firmware update." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 761 + +upsHasNoValidFirmware TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: UPS has no valid firmware." + --#TYPE "APC UPS: No firmware" + --#SUMMARY "The UPS does not have a valid firmware." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE NONOPERATIONAL + ::= 762 + +upsHasNoValidFirmwareCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: UPS now has a valid firmware." + --#TYPE "APC UPS: Now has valid firmware" + --#SUMMARY "The UPS now has a valid firmware." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 763 + + +upsLocalDisplayButtonFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "WARNING: A local display button fault exists." + --#TYPE "APC UPS: A local display button fault exists." + --#SUMMARY "The UPS has detected a local display button error. The button may be stuck in the closed position." + --#SEVERITY WARNING + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE DEGRADED + ::= 767 + +upsLocalDisplayButtonFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A local display button fault no longer exists." + --#TYPE "APC UPS: A local display button fault no longer exists." + --#SUMMARY "The UPS no longer detects a local display button error." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 768 + +upsNeedsFactorySetupFault TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: UPS needs factory setup." + --#TYPE "APC UPS: needs factory setup." + --#SUMMARY "The UPS is missing factory configuration information. The UPS needs to be set up by the factory." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE NONOPERATIONAL + ::= 769 + +upsNeedsFactorySetupFaultCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: UPS no longer needs factory setup." + --#TYPE "APC UPS: no longer needs factory setup." + --#SUMMARY "The UPS now has the required factory configuration information." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 770 + +upsEPOActive TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: Emergency Power Off (EPO) active." + --#TYPE "APC UPS: Emergency Power Off (EPO) active." + --#SUMMARY "The EPO contact on the UPS was activated causing the UPS to turn off." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE NONOPERATIONAL + ::= 771 + +upsEPOActiveCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: Emergency Power Off (EPO) now inactive." + --#TYPE "APC UPS: Emergency Power Off (EPO) now inactive." + --#SUMMARY "The EPO contact on the UPS is no longer activated. The UPS may be turned on." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 772 + +upsFirmwareMismatch TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: A firmware mismatch error exists." + --#TYPE "APC UPS: A firmware mismatch error exists." + --#SUMMARY "Parts of the system are running firmware versions not designed to work together. This may be due to an incomplete firmware update." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE NONOPERATIONAL + ::= 773 + +upsFirmwareMismatchCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: A firmware mismatch error no longer exists." + --#TYPE "APC UPS: A firmware mismatch error no longer exists." + --#SUMMARY "The firmware versions on the system are now compatible." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 774 + +upsOscillatorFailed TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "SEVERE: An oscillator error exists." + --#TYPE "APC UPS: An oscillator error exists." + --#SUMMARY "One or more system clocks no longer keeps time due to a failed oscillator. Depending on the failure, this may result in a loss of time keeping, or render parts of the system inoperable." + --#SEVERITY SEVERE + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE NONOPERATIONAL + ::= 775 + +upsOscillatorFailedCleared TRAP-TYPE + ENTERPRISE apc + VARIABLES { mtrapargsString } + DESCRIPTION + "INFORMATIONAL: An oscillator error no longer exists." + --#TYPE "APC UPS: An oscillator error no longer exists." + --#SUMMARY "The oscillator error no longer exists." + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 1 + --#HELP "" + --#HELPTAG 0 + --#STATE OPERATIONAL + ::= 776 + + +END