WebGraph-Thermo-Hygro-Barometer-MIB DEFINITIONS ::= BEGIN ---------------------------------------------------------------- -- Revison: 1.30 ---------------------------------------------------------------- -- 14.12.2009 RSS Feed -- ---------------------------------------------------------------- -- Revison: 1.29 ---------------------------------------------------------------- -- 02.06.2008 Correction wtWebGraphThermBaroHTTP -- Correction wtWebGraphThermoBaroDiag ---------------------------------------------------------------- -- Revison: 1.28 ---------------------------------------------------------------- -- 19.01.2007 Webio -- New Graphics java script base parameter ---------------------------------------------------------------- -- Revison: 1.27 ---------------------------------------------------------------- -- 09.11.2006 Webio -- DHCP enable ---------------------------------------------------------------- -- Revison: 1.26 ---------------------------------------------------------------- -- 03.08.2006 wtWebGraphThermoBaroSensorNo korrigiert -- ---------------------------------------------------------------- -- Revison: 1.25 ---------------------------------------------------------------- -- 28.06.2006 New: Community String Trap -- ---------------------------------------------------------------- -- Revison: 1.24 ---------------------------------------------------------------- -- 26.07.2005 #57606, WebGraph Thermo-Hygrometer -- CRON Zeitfunktion ---------------------------------------------------------------- -- Revison: 1.23 ---------------------------------------------------------------- -- 14.07.2005 #57606, WebGraph Thermo-Hygrometer -- FTP Funktionen ---------------------------------------------------------------- -- Revison: 1.22 ---------------------------------------------------------------- -- 17.05.2005 #57606, WebGraph Thermo-Hygrometer -- Trap NMS annotations ---------------------------------------------------------------- -- Revison: 1.21 ---------------------------------------------------------------- -- 19.04.2005 #57606, WebGraph Thermo-Hygrometer -- Mail Authentication ---------------------------------------------------------------- -- Revison: 1.20 ---------------------------------------------------------------- -- 05.11.2004 #57606, WebGraph Themo-Hygrometer -- Neu: Syslog -- ---------------------------------------------------------------- -- Revison: 1.19 ---------------------------------------------------------------- -- 08.09.2004 #57606 WebGraph Thermo-Hygrometer -- Neu: -- wtWebGraphThermoBaroAlarmRHMin -- wtWebGraphThermoBaroAlarmRHMax -- wtWebGraphThermoBaroAlarmRHHysteresis -- wtWebGraphThermoBaroPortSensorSelect -- wtWebGraphThermoBaroAlarmDeltaTemp -- wtWebGraphThermoBaroAlarmAHMin -- wtWebGraphThermoBaroAlarmAHMax ---------------------------------------------------------------- -- Revison: 1.18 ---------------------------------------------------------------- -- 21.07.2004 #57601/3/4, Webio Digital -- Neu: -- Diagnosis ---------------------------------------------------------------- -- Revison: 1.17 ---------------------------------------------------------------- -- 28.06.2004 #57630/1/2, Webio Digital -- Neu: Puls Mode ---------------------------------------------------------------- -- Revison: 1.16 ---------------------------------------------------------------- -- 16.04.2004 neu: #57632, Webio Digital EA24x24 -- -- #57630/1, Webio Digital EA12x12 -- Neu: -- wtWebioEA12x12InputCounterClear ---------------------------------------------------------------- -- Revison: 1.15 ---------------------------------------------------------------- -- 27.02.2004 #57630/1, Webio Digital EA12x12 -- Neu: -- Länge erweitert auf 32 Bit: -- wtWebioEA12x12InputValue -- wtWebioEA12x12OutputValue -- wtWebioEA12x12LoadControlView -- wtWebioEA12x12LCShutDownView -- wtWebioEA12x12SetOutput -- wtWebioEA12x12AlarmInputTrigger -- wtWebioEA12x12AlarmOutputTrigger -- wtWebioEA12x12PortOutputSafetyState ---------------------------------------------------------------- -- Revison: 1.14 ---------------------------------------------------------------- -- 16.02.2004 #57630/1, Webio Digital EA12x12 -- Neu: -- Texte: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger -- -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- Neu: -- Alarm Hysterese -- Alarm Clear Traps und Mails ---------------------------------------------------------------- -- Revison: 1.13 ---------------------------------------------------------------- -- 05.02.2004 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- Neu: -- Texte: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger ---------------------------------------------------------------- -- Revison: 1.12 ---------------------------------------------------------------- -- 05.11.2003 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- Neu: -- Mail Option: CSV attachment -- Offsetkalibrierung -- Alarm: Tcp Client mode ---------------------------------------------------------------- -- Revison: 1.11 ---------------------------------------------------------------- -- 28.10.2003 #57630/1, Webio Digital EA12x12 -- Neue Feature: -- Alarm : TCP Client mode -- INPUTS: Pulsfilter ---------------------------------------------------------------- -- Revison: 1.10 ---------------------------------------------------------------- -- 04.07.2003 #57630, Webio Digital EA12x12 -- Neuer Menübaum, neue Binärmodi -- ---------------------------------------------------------------- -- Revison: 1.09 ---------------------------------------------------------------- -- 24.03.2003 Trap Enterprise (Type 1, 2) korrigiert -- ---------------------------------------------------------------- -- Revison: 1.08 ---------------------------------------------------------------- -- 04.03.2003 Abgleich der Sprachversionen DE/US -- ---------------------------------------------------------------- -- Revison: 1.07 ---------------------------------------------------------------- -- 25.02.2003 Korrektur US: wtWebioEA12x12LoadControl ---------------------------------------------------------------- -- Revison: 1.06 ---------------------------------------------------------------- -- 24.02.2003 Neu: -- #57630, Webio EA12x12, LoadControl Group -- Korrektur: Trap variable Namen ---------------------------------------------------------------- -- Revison: 1.05 ---------------------------------------------------------------- -- 21.01.2003 Neu: -- #57630, Webio EA12x12 ---------------------------------------------------------------- -- Revison: 1.04 ---------------------------------------------------------------- -- 02.01.2003 Neu: -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer, 8 Alarme ---------------------------------------------------------------- -- Revison: 1.03 ---------------------------------------------------------------- -- 21.11.2002 Neu: -- #57604, 2xWebThermometer, BOOTP, StartupSite -- #57603, 8xWebThermometer, BOOTP, StartupSite ---------------------------------------------------------------- -- Revison: 1.02 ---------------------------------------------------------------- -- 26.07.2002 Neu: -- #57604, 2xWebThermometer -- #57603, 8xWebThermometer -- IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, PhysAddress FROM RFC1213-MIB enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI; -- IpAddress ::= -- [APPLICATION 0] -- IMPLICIT OCTET STRING (SIZE (4)) -- Counter ::= -- [APPLICATION 1] -- IMPLICIT INTEGER (0..4294967295) -- Gauge ::= -- [APPLICATION 2] -- IMPLICIT INTEGER (0..4294967295) -- TimeTicks ::= -- [APPLICATION 3] -- IMPLICIT INTEGER (0..4294967295) -- DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING -- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } -- privat OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { privat 1 } -- Wiesemann & Theis Com-Server MIB wut OBJECT IDENTIFIER ::= { enterprises 5040 } wtComServer OBJECT IDENTIFIER ::= { wut 1 } wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 } -- wtWebGraph Tree wtWebGraphThermoBaro OBJECT IDENTIFIER ::= { wtWebio 16 } -- wtWebGraphThermoBaro Tree wtWebGraphThermoBaroTemp OBJECT IDENTIFIER ::= { wtWebGraphThermoBaro 1 } wtWebGraphThermoBaroSessCntrl OBJECT IDENTIFIER ::= { wtWebGraphThermoBaro 2 } wtWebGraphThermoBaroConfig OBJECT IDENTIFIER ::= { wtWebGraphThermoBaro 3 } wtWebGraphThermoBaroDiag OBJECT IDENTIFIER ::= { wtWebGraphThermoBaro 4 } -- wtWebGraphThermoBaroConfig Tree wtWebGraphThermoBaroDevice OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroConfig 1 } wtWebGraphThermoBaroPorts OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroConfig 2 } wtWebGraphThermoBaroManufact OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroConfig 3 } -- wtWebGraphThermoBaroDevice Tree wtWebGraphThermoBaroText OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 1 } wtWebGraphThermoBaroTimeDate OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 2 } wtWebGraphThermoBaroBasic OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 3 } wtWebGraphThermoBaroDatalogger OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 4 } wtWebGraphThermoBaroAlarm OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 5 } wtWebGraphThermoBaroGraphics OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 6 } -- wtWebGraphThermoBaroTimeDate Tree wtWebGraphThermoBaroTimeZone OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroTimeDate 1 } wtWebGraphThermoBaroTimeServer OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroTimeDate 2 } wtWebGraphThermoBaroDeviceClock OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroTimeDate 3 } -- wtWebGraphThermoBaroBasic Tree wtWebGraphThermoBaroNetwork OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 1 } wtWebGraphThermoBaroHTTP OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 2 } wtWebGraphThermoBaroMail OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 3 } wtWebGraphThermoBaroSNMP OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 4 } wtWebGraphThermoBaroUDP OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 5 } wtWebGraphThermoBaroSyslog OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 6 } wtWebGraphThermoBaroFTP OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 7 } wtWebGraphThermoBaroRSS OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 8 } -- wtWebGraphThermoBaroGraphics Tree wtWebGraphThermoBaroGraphicsBase OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroGraphics 1 } wtWebGraphThermoBaroGraphicsSelect OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroGraphics 2 } wtWebGraphThermoBaroGraphicsScale OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroGraphics 3 } -- wtWebGraphThermoBaroTemp Group ------------------------ wtWebGraphThermoBaroSensors OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Anzahl der Sensoren" ::= { wtWebGraphThermoBaroTemp 1 } -- Interface Table wtWebGraphThermoBaroSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphThermoBaroSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste der Sensoren." ::= { wtWebGraphThermoBaroTemp 2 } wtWebGraphThermoBaroSensorEntry OBJECT-TYPE SYNTAX WtWebGraphThermoBaroSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Nummern der Sensoren." INDEX { wtWebGraphThermoBaroSensorNo } ::= { wtWebGraphThermoBaroSensorTable 1 } WtWebGraphThermoBaroSensorEntry ::= SEQUENCE { wtWebGraphThermoBaroSensorNo INTEGER } wtWebGraphThermoBaroSensorNo OBJECT-TYPE SYNTAX INTEGER (1..3) ACCESS read-only STATUS mandatory DESCRIPTION "Nummer des Sensors." ::= { wtWebGraphThermoBaroSensorEntry 1 } -- wtWebGraphThermoBaroTempValue Table wtWebGraphThermoBaroTempValueTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphThermoBaroTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste Sensormesswerte korrespondiernd zu den Kanalnummern." ::= { wtWebGraphThermoBaroTemp 3 } wtWebGraphThermoBaroTempValueEntry OBJECT-TYPE SYNTAX WtWebGraphThermoBaroTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Messwerte der Sensoren." INDEX { wtWebGraphThermoBaroSensorNo } ::= { wtWebGraphThermoBaroTempValueTable 1 } WtWebGraphThermoBaroTempValueEntry ::= SEQUENCE{ wtWebGraphThermoBaroTempValue OCTET STRING } wtWebGraphThermoBaroTempValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Messwert des Sensors, ASCII, 5 Zeichen lang." ::= { wtWebGraphThermoBaroTempValueEntry 1 } -- wtWebGraphThermoBaroBinaryTempValue Table wtWebGraphThermoBaroBinaryTempValueTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphThermoBaroBinaryTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste binärer Messwerte korrespondiernd zu den Kanalnummern." ::= { wtWebGraphThermoBaroTemp 4 } wtWebGraphThermoBaroBinaryTempValueEntry OBJECT-TYPE SYNTAX WtWebGraphThermoBaroBinaryTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binäre Messwerte der Sensoren." INDEX { wtWebGraphThermoBaroSensorNo } ::= { wtWebGraphThermoBaroBinaryTempValueTable 1 } WtWebGraphThermoBaroBinaryTempValueEntry ::= SEQUENCE{ wtWebGraphThermoBaroBinaryTempValue INTEGER } wtWebGraphThermoBaroBinaryTempValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Binärer Messwert des Sensors in 1/10 Grad Celcius oder 1/10 Prozent, vorzeichenbehaftete Zahl, der Wert 0x4FFF6 zeigt einen ungültigen Messwert an." ::= { wtWebGraphThermoBaroBinaryTempValueEntry 1 } -- wtWebGraphThermoBaroTempValuePkt Table wtWebGraphThermoBaroTempValuePktTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphThermoBaroTempValuePktEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste Temperaturwerte korrespondiernd zu den Kanalnummern." ::= { wtWebGraphThermoBaroTemp 8 } wtWebGraphThermoBaroTempValuePktEntry OBJECT-TYPE SYNTAX WtWebGraphThermoBaroTempValuePktEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Temperaturen der Sensoren." INDEX { wtWebGraphThermoBaroSensorNo } ::= { wtWebGraphThermoBaroTempValuePktTable 1 } WtWebGraphThermoBaroTempValuePktEntry ::= SEQUENCE{ wtWebGraphThermoBaroTempValuePkt OCTET STRING } wtWebGraphThermoBaroTempValuePkt OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperaturwert des Sensors, ASCII, 5 Zeichen lang, dezimal Punkt." ::= { wtWebGraphThermoBaroTempValuePktEntry 1 } -- wtWebGraphThermoBaroSessCntrl Group -------------------------------- wtWebGraphThermoBaroSessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Durch Eintrag diese Passworts wird eine Session eröffnet, die durch Schreiben einer 1 in wtWebGraphThermoBaroSessCntrlLogout beendet wird. Gelesen liefert diese Variable einen String der Länge Null." ::= { wtWebGraphThermoBaroSessCntrl 1 } wtWebGraphThermoBaroSessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER { wtWebGraphThermoBaroSessCntrl-NoSession(0), wtWebGraphThermoBaroSessCntrl-Session(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Wenn sich das Gerät im SNMP-Konfigurationsmodus befindet, wird der Wert 1 zurückgeliefert, ansonsten 0. Ist der ausgelesene Wert 0 obwohl das Passwort geschrieben wurde, befindet sich das Gerät bereits im Configmodus und die Variablen können nur gelesen werden." ::= { wtWebGraphThermoBaroSessCntrl 2 } wtWebGraphThermoBaroSessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Wenn sich das Gerät im Konfigurationsmodus befindet und die Session wurde von diesem SNMP Manager eröffnet, kann durch Schreiben einer 1 in diese Variable die Session beendet werden und alle Parameter werden gespeichert. Durch Schreiben einer 2 werden alle Eingaben wieder verworfen. Gelesen liefert diese Variable den Wert 0." ::= { wtWebGraphThermoBaroSessCntrl 3 } wtWebGraphThermoBaroSessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieses Passwort schützt den Zugang der Variablen mit Administratorrechten. Es kann nur vom Administrator verändert werden. Wurde kein Passwort vergeben so ist public das gültige Passwort. Gelesen liefert diese Variable einen Null-Pointer." ::= { wtWebGraphThermoBaroSessCntrl 4 } wtWebGraphThermoBaroSessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieses Passwort schützt den Zugang der Variablen mit Configuratorrechten. Es kann vom Administrator und vom Configurator verändert werden. Wurde kein Passwort vergeben so ist public das gültige Passwort.Gelesen liefert diese Variable einen Null-Pointer." ::= { wtWebGraphThermoBaroSessCntrl 5 } -- wtWebGraphThermoBaroText Group ------------------------ wtWebGraphThermoBaroDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name des Webio's, der userdefinierbar ist." ::= { wtWebGraphThermoBaroText 1 } wtWebGraphThermoBaroDeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Beschreibung des Webio's, die userdefinierbar ist." ::= { wtWebGraphThermoBaroText 2 } wtWebGraphThermoBaroDeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Aufstellort des Webio's, die userdefinierbar ist." ::= { wtWebGraphThermoBaroText 3 } wtWebGraphThermoBaroDeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Kontaktadresse im Servicefall des Webio's, die userdefinierbar ist." ::= { wtWebGraphThermoBaroText 4 } -- wtWebGraphThermoBaroTimeZone Group ---------------------------- wtWebGraphThermoBaroTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset Stunden der Zeitzone (Winterzeit) in Bezug auf UTC." ::= { wtWebGraphThermoBaroTimeZone 1 } wtWebGraphThermoBaroTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset Minuten der Zeitzone (Winterzeit) in Bezug auf UTC." ::= { wtWebGraphThermoBaroTimeZone 2 } wtWebGraphThermoBaroTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Bedingung: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Apply Timezone" ::= { wtWebGraphThermoBaroTimeZone 3 } wtWebGraphThermoBaroStTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset Stunden der Zeitzone (Sommerzeit) in Bezug auf UTC." ::= { wtWebGraphThermoBaroTimeZone 4 } wtWebGraphThermoBaroStTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset Minuten der Zeitzone (Sommerzeit) in Bezug auf UTC." ::= { wtWebGraphThermoBaroTimeZone 5 } wtWebGraphThermoBaroStTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Bedingung: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Apply Summertime" ::= { wtWebGraphThermoBaroTimeZone 6 } wtWebGraphThermoBaroStTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebGraphThermoBaroStartMonth-January(1), wtWebGraphThermoBaroStartMonth-February(2), wtWebGraphThermoBaroStartMonth-March(3), wtWebGraphThermoBaroStartMonth-April(4), wtWebGraphThermoBaroStartMonth-May(5), wtWebGraphThermoBaroStartMonth-June(6), wtWebGraphThermoBaroStartMonth-July(7), wtWebGraphThermoBaroStartMonth-August(8), wtWebGraphThermoBaroStartMonth-September(9), wtWebGraphThermoBaroStartMonth-October(10), wtWebGraphThermoBaroStartMonth-November(11), wtWebGraphThermoBaroStartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Monat, in dem von Winterzeit auf Sommerzeit umgestellt wird." ::= { wtWebGraphThermoBaroTimeZone 7 } wtWebGraphThermoBaroStTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebGraphThermoBaroStartMode-first(1), wtWebGraphThermoBaroStartMode-second(2), wtWebGraphThermoBaroStartMode-third(3), wtWebGraphThermoBaroStartMode-fourth(4), wtWebGraphThermoBaroStartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Modus des Wochentages, bei dem von Winterzeit auf Sommerzeit umgestellt wird." ::= { wtWebGraphThermoBaroTimeZone 8 } wtWebGraphThermoBaroStTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebGraphThermoBaroStartWday-Sunday(1), wtWebGraphThermoBaroStartWday-Monday(2), wtWebGraphThermoBaroStartWday-Tuesday(3), wtWebGraphThermoBaroStartWday-Thursday(4), wtWebGraphThermoBaroStartWday-Wednesday(5), wtWebGraphThermoBaroStartWday-Friday(6), wtWebGraphThermoBaroStartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Wochentag, bei dem von Winterzeit auf Sommerzeit umgestellt wird" ::= { wtWebGraphThermoBaroTimeZone 9 } wtWebGraphThermoBaroStTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Stunde, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC umgestellt wird." ::= { wtWebGraphThermoBaroTimeZone 10 } wtWebGraphThermoBaroStTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC umgestellt wird." ::= { wtWebGraphThermoBaroTimeZone 11 } wtWebGraphThermoBaroStTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebGraphThermoBaroStopMonth-January(1), wtWebGraphThermoBaroStopMonth-February(2), wtWebGraphThermoBaroStopMonth-March(3), wtWebGraphThermoBaroStopMonth-April(4), wtWebGraphThermoBaroStopMonth-May(5), wtWebGraphThermoBaroStopMonth-June(6), wtWebGraphThermoBaroStopMonth-July(7), wtWebGraphThermoBaroStopMonth-August(8), wtWebGraphThermoBaroStopMonth-September(9), wtWebGraphThermoBaroStopMonth-October(10), wtWebGraphThermoBaroStopMonth-November(11), wtWebGraphThermoBaroStopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Monat, bei dem von Sommerzeit auf Winterzeit umgestellt wird." ::= { wtWebGraphThermoBaroTimeZone 12 } wtWebGraphThermoBaroStTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebGraphThermoBaroStopMode-first(1), wtWebGraphThermoBaroStopMode-second(2), wtWebGraphThermoBaroStopMode-third(3), wtWebGraphThermoBaroStopMode-fourth(4), wtWebGraphThermoBaroStopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Modus des Wochentages, bei dem von Sommerzeit auf Winterzeit umgestellt wird." ::= { wtWebGraphThermoBaroTimeZone 13 } wtWebGraphThermoBaroStTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebGraphThermoBaroStopWday-Sunday(1), wtWebGraphThermoBaroStopWday-Monday(2), wtWebGraphThermoBaroStopWday-Tuesday(3), wtWebGraphThermoBaroStopWday-Thursday(4), wtWebGraphThermoBaroStopWday-Wednesday(5), wtWebGraphThermoBaroStopWday-Friday(6), wtWebGraphThermoBaroStopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Wochentage, bei dem von Sommerzeit auf Winterzeit umgestellt wird." ::= { wtWebGraphThermoBaroTimeZone 14 } wtWebGraphThermoBaroStTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Stunde, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC umgestellt wird." ::= { wtWebGraphThermoBaroTimeZone 15 } wtWebGraphThermoBaroStTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC umgestellt wird." ::= { wtWebGraphThermoBaroTimeZone 16 } -- wtWebGraphThermoBaroTimeServer Group ---------------------------- wtWebGraphThermoBaroTimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP-Adresse oder Name des 1. Time Servers in ASCII" ::= { wtWebGraphThermoBaroTimeServer 1 } wtWebGraphThermoBaroTimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP-Adresse oder Name des 2. Time Servers in ASCII" ::= { wtWebGraphThermoBaroTimeServer 2 } wtWebGraphThermoBaroTsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Bedingung: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Apply Time Server" ::= { wtWebGraphThermoBaroTimeServer 3 } wtWebGraphThermoBaroTsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Die Abfrage der Timeserver erfolgt zu dieser vollen Stunde (0-23)." ::= { wtWebGraphThermoBaroTimeServer 4 } -- wtWebGraphThermoBaroDeviceClock Group ---------------------------- wtWebGraphThermoBaroClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Uhrzeit Stunde, unter Berücksichtigung der Zeitzoneneinstellungen." ::= { wtWebGraphThermoBaroDeviceClock 1 } wtWebGraphThermoBaroClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Uhrzeit Minute, unter Berücksichtigung der Zeitzoneneinstellungen." ::= { wtWebGraphThermoBaroDeviceClock 2 } wtWebGraphThermoBaroClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Datum: Tag des Monats, unter Berücksichtigung der Zeitzoneneinstellungen." ::= { wtWebGraphThermoBaroDeviceClock 3 } wtWebGraphThermoBaroClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebGraphThermoBaroClockMonth-January(1), wtWebGraphThermoBaroClockMonth-February(2), wtWebGraphThermoBaroClockMonth-March(3), wtWebGraphThermoBaroClockMonth-April(4), wtWebGraphThermoBaroClockMonth-May(5), wtWebGraphThermoBaroClockMonth-June(6), wtWebGraphThermoBaroClockMonth-July(7), wtWebGraphThermoBaroClockMonth-August(8), wtWebGraphThermoBaroClockMonth-September(9), wtWebGraphThermoBaroClockMonth-October(10), wtWebGraphThermoBaroClockMonth-November(11), wtWebGraphThermoBaroClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Datum: Monat, unter Berücksichtigung der Zeitzoneneinstellungen." ::= { wtWebGraphThermoBaroDeviceClock 4 } wtWebGraphThermoBaroClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Datum: Jahr, unter Berücksichtigung der Zeitzoneneinstellungen." ::= { wtWebGraphThermoBaroDeviceClock 5 } -- wtWebGraphThermoBaroNetwork Group ------------------------ wtWebGraphThermoBaroIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP-Adresse des Webio's" ::= { wtWebGraphThermoBaroNetwork 1 } wtWebGraphThermoBaroSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnetmask des Webio's" ::= { wtWebGraphThermoBaroNetwork 2 } wtWebGraphThermoBaroGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway des Webio's" ::= { wtWebGraphThermoBaroNetwork 3 } wtWebGraphThermoBaroDnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP-Adresse des 1. DNS Servers in ASCII" ::= { wtWebGraphThermoBaroNetwork 4 } wtWebGraphThermoBaroDnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP-Adresse des 2. DNS Servers in ASCII" ::= { wtWebGraphThermoBaroNetwork 5 } wtWebGraphThermoBaroAddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Zusatzkonfiguration (1=EIN): Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1: DHCP disable Bit 0: BOOTP disable " ::= { wtWebGraphThermoBaroNetwork 6 } -- wtWebGraphThermoBaroHTTP Group -------------------------------- wtWebGraphThermoBaroStartup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Legt die Startseite fest, nur eine Auswahl zulässig: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm" ::= { wtWebGraphThermoBaroHTTP 1 } wtWebGraphThermoBaroGetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Wenn freigeschaltet, wird eine Erkennungssequenz und /oder ein HTTP-Kopf nach jeder GET-Anfrage der Antwort vorangestellt: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-6: ungenutzt Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebGraphThermoBaroHTTP 2 } wtWebGraphThermoBaroHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Port, an den die TCP-Anfragen gesendet werden können (Default: 80)." ::= { wtWebGraphThermoBaroHTTP 3 } -- wtWebGraphThermoBaroMail Group -------------------------------- wtWebGraphThermoBaroMailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Gerätename für die Mail-Administration." ::= { wtWebGraphThermoBaroMail 1 } wtWebGraphThermoBaroMailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply-Adresse für den Mailserver." ::= { wtWebGraphThermoBaroMail 2 } wtWebGraphThermoBaroMailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name oder Ip-Adresse des Mailservers." ::= { wtWebGraphThermoBaroMail 3 } wtWebGraphThermoBaroMailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Erlaubt das versenden von Mails: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Mail enable" ::= { wtWebGraphThermoBaroMail 4 } wtWebGraphThermoBaroMailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Auswahl des Authenticationmodi: die OCTETS werden bitweise interpretiert, es darf nur ein Bit gesetzt sein. Bit 0 entspricht dem LSB. OCTET 1: ungenutzt OCTET 2: ungenutzt OCTET 3: ungenutzt OCTET 4: Bit 3-7: ungenutzt Bit 2 : POP3 vor SMTP Bit 1 : ESMTP, Authentifizierung Bit 0 : SMTP, keine Authentifizierung" ::= { wtWebGraphThermoBaroMail 5 } wtWebGraphThermoBaroMailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name des Postfaches / Postfachusers." ::= { wtWebGraphThermoBaroMail 6 } wtWebGraphThermoBaroMailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Passwort zur Identifizierung des Users." ::= { wtWebGraphThermoBaroMail 7 } wtWebGraphThermoBaroMailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name oder Ip-Adresse des POP3 Servers." ::= { wtWebGraphThermoBaroMail 8 } -- wtWebGraphThermoBaroSNMP Group -------------------------------- wtWebGraphThermoBaroSnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebGraphThermoBaroSNMP 1 } wtWebGraphThermoBaroSnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebGraphThermoBaroSNMP 2 } wtWebGraphThermoBaroSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name oder IP-Adresse des SNMP-Managers, der den System Trap entgegen nimmt." ::= { wtWebGraphThermoBaroSNMP 3 } wtWebGraphThermoBaroSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Triggerbedingungen: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: ungenutzt" ::= { wtWebGraphThermoBaroSNMP 4 } wtWebGraphThermoBaroSnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 schaltet SNMP frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : SNMP enable" ::= { wtWebGraphThermoBaroSNMP 5 } wtWebGraphThermoBaroSnmpCommunityStringTrap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string der Traps." ::= { wtWebGraphThermoBaroSNMP 6 } -- wtWebGraphThermoBaroUDP Group -------------------------------- wtWebGraphThermoBaroUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Udp Port, an den die Udp-Anfragen GET Single gesendet werden können" ::= { wtWebGraphThermoBaroUDP 1 } wtWebGraphThermoBaroUdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Schaltet UDP frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : UDP enable" ::= { wtWebGraphThermoBaroUDP 2 } -- wtWebGraphThermoBaroSyslog Group -------------------------------- wtWebGraphThermoBaroSyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name oder IP-Adresse des Syslog-Servers, der die Syslog-Nachricht entgegen nimmt." ::= { wtWebGraphThermoBaroSyslog 1 } wtWebGraphThermoBaroSyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnummer des Syslog-Servers, default ist 514." ::= { wtWebGraphThermoBaroSyslog 2 } wtWebGraphThermoBaroSyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Triggerbedingungen: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: ungenutzt" ::= { wtWebGraphThermoBaroSyslog 3 } wtWebGraphThermoBaroSyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 schaltet Syslog frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Syslog enable" ::= { wtWebGraphThermoBaroSyslog 4 } -- wtWebGraphThermoBaroFTP Group -------------------------------- wtWebGraphThermoBaroFTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name oder IP-Adresse des FTP-Servers, der die FTP-Nachricht entgegen nimmt." ::= { wtWebGraphThermoBaroFTP 1 } wtWebGraphThermoBaroFTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnummer des Kontrollports des FTP-Servers, default ist 21." ::= { wtWebGraphThermoBaroFTP 2 } wtWebGraphThermoBaroFTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: Name des Anwenders." ::= { wtWebGraphThermoBaroFTP 3 } wtWebGraphThermoBaroFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: Passwort des Anwenders." ::= { wtWebGraphThermoBaroFTP 4 } wtWebGraphThermoBaroFTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: Account-Name des Anwenderkontos." ::= { wtWebGraphThermoBaroFTP 5 } wtWebGraphThermoBaroFTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 schaltet den FTP Server in den Passiv-Modus, der Client kontrolliert die Datenverbindung allein: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : PASV enable" ::= { wtWebGraphThermoBaroFTP 6 } wtWebGraphThermoBaroFTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 schaltet FTP frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : FTP enable" ::= { wtWebGraphThermoBaroFTP 7 } -- wtWebGraphThermoBaroDatalogger Group -------------------------------- wtWebGraphThermoBaroLoggerTimebase OBJECT-TYPE SYNTAX INTEGER { wtWebGraphThermoBaroDatalogger-1Min(1), wtWebGraphThermoBaroDatalogger-5Min(2), wtWebGraphThermoBaroDatalogger-15Min(3), wtWebGraphThermoBaroDatalogger-60Min(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Zeitbasis des Dataloggers" ::= { wtWebGraphThermoBaroDatalogger 1 } wtWebGraphThermoBaroLoggerSensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Triggerbedingungen: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : Sensor 1 Bit 1 : Sensor 2 Bit 2-7: ungenutzt" ::= { wtWebGraphThermoBaroDatalogger 2 } -- wtWebGraphThermoBaroRSS Group -------------------------------- wtWebGraphThermoBaroRSSChannelTitle OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name des RSS Feeds." ::= { wtWebGraphThermoBaroRSS 1 } wtWebGraphThermoBaroRSSChannelLink OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Link des RSS Feeds." ::= { wtWebGraphThermoBaroRSS 2 } wtWebGraphThermoBaroRSSChannelDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Beschreibungstext des RSS Feeds." ::= { wtWebGraphThermoBaroRSS 3 } wtWebGraphThermoBaroRSSChannelImage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Link zu eine Bild, dass mit dem Datensätzen in der Kopfzeile angezeigt wird." ::= { wtWebGraphThermoBaroRSS 4 } wtWebGraphThermoBaroRSSChannelImageTitle OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name des Bildes." ::= { wtWebGraphThermoBaroRSS 5 } wtWebGraphThermoBaroRSSChannelImageLink OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Link, der dem Bild in der Kopfzeile hinterlegt wird." ::= { wtWebGraphThermoBaroRSS 6 } wtWebGraphThermoBaroRSSChannelItemTitle OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name des RSS Feeds Eintrages." ::= { wtWebGraphThermoBaroRSS 7 } wtWebGraphThermoBaroRSSChannelItemLink OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Link des RSS Feeds Eintrages." ::= { wtWebGraphThermoBaroRSS 8 } wtWebGraphThermoBaroRSSChannelItemDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Text des RSS Feeds Eintrages." ::= { wtWebGraphThermoBaroRSS 9 } wtWebGraphThermoBaroRSSChannelItemQuantity OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Anzahl der auszugebenen RSS Feeds Einträge." ::= { wtWebGraphThermoBaroRSS 10 } -- wtWebGraphThermoBaroAlarm Group -------------------------------- wtWebGraphThermoBaroAlarmCount OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Anzahl der unabhängigen Alarme." ::= { wtWebGraphThermoBaroAlarm 1 } -- Alarm Interface Table wtWebGraphThermoBaroAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphThermoBaroAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste der Alarmindizes." ::= { wtWebGraphThermoBaroAlarm 2 } wtWebGraphThermoBaroAlarmIfEntry OBJECT-TYPE SYNTAX WtWebGraphThermoBaroAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Nummern der Alarme." INDEX { wtWebGraphThermoBaroAlarmNo } ::= { wtWebGraphThermoBaroAlarmIfTable 1 } WtWebGraphThermoBaroAlarmIfEntry ::= SEQUENCE { wtWebGraphThermoBaroAlarmNo INTEGER } wtWebGraphThermoBaroAlarmNo OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Nummer des Alarms." ::= { wtWebGraphThermoBaroAlarmIfEntry 1 } -- Alarm Table wtWebGraphThermoBaroAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphThermoBaroAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste der Einstellungen abhängig von der Alarmnummer." ::= { wtWebGraphThermoBaroAlarm 3 } wtWebGraphThermoBaroAlarmEntry OBJECT-TYPE SYNTAX WtWebGraphThermoBaroAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm-Parameter der einzelnen Alarme." INDEX { wtWebGraphThermoBaroAlarmNo } ::= { wtWebGraphThermoBaroAlarmTable 1 } WtWebGraphThermoBaroAlarmEntry ::= SEQUENCE { wtWebGraphThermoBaroAlarmTrigger OCTET STRING, wtWebGraphThermoBaroAlarmMin OCTET STRING, wtWebGraphThermoBaroAlarmMax OCTET STRING, wtWebGraphThermoBaroAlarmHysteresis OCTET STRING, wtWebGraphThermoBaroAlarmDelay OCTET STRING, wtWebGraphThermoBaroAlarmInterval OCTET STRING, wtWebGraphThermoBaroAlarmEnable OCTET STRING, wtWebGraphThermoBaroAlarmEMailAddr OCTET STRING, wtWebGraphThermoBaroAlarmMailSubject OCTET STRING, wtWebGraphThermoBaroAlarmMailText OCTET STRING, wtWebGraphThermoBaroAlarmManagerIP OCTET STRING, wtWebGraphThermoBaroAlarmTrapText OCTET STRING, wtWebGraphThermoBaroAlarmMailOptions OCTET STRING, wtWebGraphThermoBaroAlarmTcpIpAddr OCTET STRING, wtWebGraphThermoBaroAlarmTcpPort INTEGER, wtWebGraphThermoBaroAlarmTcpText OCTET STRING, wtWebGraphThermoBaroAlarmClearMailSubject OCTET STRING, wtWebGraphThermoBaroAlarmClearMailText OCTET STRING, wtWebGraphThermoBaroAlarmClearTrapText OCTET STRING, wtWebGraphThermoBaroAlarmClearTcpText OCTET STRING, wtWebGraphThermoBaroAlarmDeltaTemp OCTET STRING, wtWebGraphThermoBaroAlarmRHMin OCTET STRING, wtWebGraphThermoBaroAlarmRHMax OCTET STRING, wtWebGraphThermoBaroAlarmRHHysteresis OCTET STRING, wtWebGraphThermoBaroAlarmAHMin OCTET STRING, wtWebGraphThermoBaroAlarmAHMax OCTET STRING, wtWebGraphThermoBaroAlarmSyslogIpAddr OCTET STRING, wtWebGraphThermoBaroAlarmSyslogPort INTEGER, wtWebGraphThermoBaroAlarmSyslogText OCTET STRING, wtWebGraphThermoBaroAlarmSyslogClearText OCTET STRING, wtWebGraphThermoBaroAlarmFtpDataPort OCTET STRING, wtWebGraphThermoBaroAlarmFtpFileName OCTET STRING, wtWebGraphThermoBaroAlarmFtpText OCTET STRING, wtWebGraphThermoBaroAlarmFtpClearText OCTET STRING, wtWebGraphThermoBaroAlarmFtpOption OCTET STRING, wtWebGraphThermoBaroAlarmTimerCron OCTET STRING } wtWebGraphThermoBaroAlarmTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Triggerbedingungen: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Bit 3: Sensor lost Bit 4-7 ungenutzt Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: ungenutzt" ::= { wtWebGraphThermoBaroAlarmEntry 1 } wtWebGraphThermoBaroAlarmMin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum Temperatur in Grad mit maximal 2 Nachkommastellen." ::= { wtWebGraphThermoBaroAlarmEntry 2 } wtWebGraphThermoBaroAlarmMax OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum Temperatur in Grad mit maximal 2 Nachkommastellen." ::= { wtWebGraphThermoBaroAlarmEntry 3 } wtWebGraphThermoBaroAlarmHysteresis OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bei Überschreiten der Temperatur Min+Hyst. und Unterschreiten der Temperatur Max-Hyst. wird der Alarm gelöscht: pos. Temperaturdifferenz in Grad mit maximal 2 Nachkommastellen." ::= { wtWebGraphThermoBaroAlarmEntry 4 } wtWebGraphThermoBaroAlarmDelay OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Der Alarm wird erst ausgelöst, wenn für die Dauer dieser Zeit die Alarmbedingungen erfüllt sind (Zeit in Minuten)." ::= { wtWebGraphThermoBaroAlarmEntry 5 } wtWebGraphThermoBaroAlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Sendeintervall von Alarmmeldungen." ::= { wtWebGraphThermoBaroAlarmEntry 6 } wtWebGraphThermoBaroAlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Alarmfreischaltung: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable" ::= { wtWebGraphThermoBaroAlarmEntry 7 } wtWebGraphThermoBaroAlarmEMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail Adresse, an die die Alarmmail gesendet werden soll." ::= { wtWebGraphThermoBaroAlarmEntry 8 } wtWebGraphThermoBaroAlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Betreffzeile der Alarmmail." ::= { wtWebGraphThermoBaroAlarmEntry 9 } wtWebGraphThermoBaroAlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Text der Alarmmail: liefert die aktuelle Temperatur; n = 1..8. liefert die aktuelle Zeit." ::= { wtWebGraphThermoBaroAlarmEntry 10 } wtWebGraphThermoBaroAlarmManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name oder IP-Adresse des SNMP-Managers, der den Trap entgegen nimmt." ::= { wtWebGraphThermoBaroAlarmEntry 11 } wtWebGraphThermoBaroAlarmTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieser Text wird im Trapbody gesendet." ::= { wtWebGraphThermoBaroAlarmEntry 12 } wtWebGraphThermoBaroAlarmMailOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Optionen: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: ungenutzt" ::= { wtWebGraphThermoBaroAlarmEntry 13 } wtWebGraphThermoBaroAlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP-Adresse des Gerätes, dass eine TCP-Nachricht empfangen soll." ::= { wtWebGraphThermoBaroAlarmEntry 14 } wtWebGraphThermoBaroAlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Portnummer des Gerätes, dass eine TCP-Nachricht empfangen soll." ::= { wtWebGraphThermoBaroAlarmEntry 15 } wtWebGraphThermoBaroAlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieser Text wird im TCP Trapbody gesendet." ::= { wtWebGraphThermoBaroAlarmEntry 16 } wtWebGraphThermoBaroAlarmClearMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Betreffzeile der Alarm Clear Mail." ::= { wtWebGraphThermoBaroAlarmEntry 17 } wtWebGraphThermoBaroAlarmClearMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Text der Alarm Clear Mail: liefert die aktuelle Temperatur; n = 1..8. liefert die aktuelle Zeit." ::= { wtWebGraphThermoBaroAlarmEntry 18 } wtWebGraphThermoBaroAlarmClearTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieser Text wird im Trapbody gesendet." ::= { wtWebGraphThermoBaroAlarmEntry 19 } wtWebGraphThermoBaroAlarmClearTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieser Text wird im TCP Trapbody gesendet." ::= { wtWebGraphThermoBaroAlarmEntry 20 } wtWebGraphThermoBaroAlarmDeltaTemp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximale Temperaturänderung in Grad/min mit maximal 2 Nachkommastellen. Es wird ein Mittelwert einer Periode von 5 Minuten verglichen." ::= { wtWebGraphThermoBaroAlarmEntry 21 } wtWebGraphThermoBaroAlarmRHMin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum rel. Feuchte in Prozent mit maximal 2 Nachkommastellen." ::= { wtWebGraphThermoBaroAlarmEntry 22 } wtWebGraphThermoBaroAlarmRHMax OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum rel.Feuchte in Prozent mit maximal 2 Nachkommastellen." ::= { wtWebGraphThermoBaroAlarmEntry 23 } wtWebGraphThermoBaroAlarmRHHysteresis OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Hysterese rel. Feuchte in Prozent mit maximal 2 Nachkommastellen." ::= { wtWebGraphThermoBaroAlarmEntry 24 } wtWebGraphThermoBaroAlarmAHMin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum abs. Feuchte in g/(m*m*m) mit maximal 2 Nachkommastellen." ::= { wtWebGraphThermoBaroAlarmEntry 25 } wtWebGraphThermoBaroAlarmAHMax OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum abs. Feuchte in g/(m*m*m) mit maximal 2 Nachkommastellen." ::= { wtWebGraphThermoBaroAlarmEntry 26 } wtWebGraphThermoBaroAlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP-Adresse des Gerätes, dass eine Syslog-Nachricht empfangen soll." ::= { wtWebGraphThermoBaroAlarmEntry 27 } wtWebGraphThermoBaroAlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Portnummer des Gerätes, dass eine Syslog-Nachricht empfangen soll, default Port ist 514." ::= { wtWebGraphThermoBaroAlarmEntry 28 } wtWebGraphThermoBaroAlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Jede Syslog-Nachricht beginnt mit einem Prioritätsschlüssel, einem Zeitstempel und der Host Ip-Nummer gemäß RFC3164. Dieser Text wird im darauf folgenden Syslog-Nachrichtenteil gesendet." ::= { wtWebGraphThermoBaroAlarmEntry 29 } wtWebGraphThermoBaroAlarmSyslogClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Jede Syslog-Nachricht beginnt mit einem Prioritätsschlüssel, einem Zeitstempel und der Host Ip-Nummer gemäß RFC3164. Dieser Text wird im darauf folgenden Syslog-Nachrichtenteil gesendet." ::= { wtWebGraphThermoBaroAlarmEntry 30 } wtWebGraphThermoBaroAlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Lokaler Datenport: 1..65535 oder AUTO: der nächste ungenutzte Port wird automatisch zugewiesen." ::= { wtWebGraphThermoBaroAlarmEntry 31 } wtWebGraphThermoBaroAlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Der File Name kann auch Pfadinformationen enthalten." ::= { wtWebGraphThermoBaroAlarmEntry 32 } wtWebGraphThermoBaroAlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieser Text wird in die angegebene Datei geschrieben." ::= { wtWebGraphThermoBaroAlarmEntry 33 } wtWebGraphThermoBaroAlarmFtpClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieser Text wird in die angegebene Datei geschrieben." ::= { wtWebGraphThermoBaroAlarmEntry 34 } wtWebGraphThermoBaroAlarmFtpOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Optionen, nur eine Option darf eingeschaltet sein: STORE = Datei ersetzen APPEND = Nachrichten ans Dateiende anhängen Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: ungenutzt" ::= { wtWebGraphThermoBaroAlarmEntry 35 } wtWebGraphThermoBaroAlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieser Eintrag enthält 5 Leerzeichen- oder Tab-getrente Felder zur Definition von zeitgesteuerten Ausgabe von Alarmnachrichten. Jedes der 5 Felder muss mit der aktuelle Zeit übereinstimmen, um das Senden einer Nachricht auszulösen, Wochentag und Monatstag werden getrennt ausgewertet. Feld möglicher Zahlenbereich 1: Minuten 0-59 2. Stunden 0-23, 0 ist Mitternacht 3: Monatstag 1-31 4: Monat 1-12 5: Wochentag 0-6, 0 ist Sonntag Für jedes Feld kann nun angegeben werden: - eine ganze Zahl aus dem angegebenen Zahlenbereich - ein Teil-Zahlenbereich (wie z.B. 1-5) innerhalb des angegebenen Zahlenbereichs - eine mit Komma getrennte Liste von ganzen Zahlen oder Tei-Zahlenbereichen (wie z.B. 2,4-6,8,10) - ein Stern * (deckt den gesamten erlaubten Bereich ab) - ein / gibt die Schrittweite bei Teil-Zahlenbereichen an (z.B. 0-59/2 jede zweite Minute)." ::= { wtWebGraphThermoBaroAlarmEntry 36 } -- wtWebGraphThermoBaroGraphicsBase Group ---------------------------- wtWebGraphThermoBaroGraphicsBaseEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Legt die Anzeigeelemente der Grafik fest: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5-7: ungenutzt" ::= { wtWebGraphThermoBaroGraphicsBase 1 } wtWebGraphThermoBaroGraphicsBaseWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Definiert die Breite der Grafik in Pixeln." ::= { wtWebGraphThermoBaroGraphicsBase 2 } wtWebGraphThermoBaroGraphicsBaseHeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Definiert die Höhe der Grafik in Pixeln." ::= { wtWebGraphThermoBaroGraphicsBase 3 } wtWebGraphThermoBaroGraphicsBaseFrameColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Farbe des Rahmens in der grafischen Darstellung." ::= { wtWebGraphThermoBaroGraphicsBase 4 } wtWebGraphThermoBaroGraphicsBaseBackgroundColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Farbe der Hintergrundfarbe in der grafischen Darstellung." ::= { wtWebGraphThermoBaroGraphicsBase 5 } wtWebGraphThermoBaroGraphicsBasePollingrate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Definiert die Abfragerate in Sekunden, mit der die Grafik aktualisiert wird." ::= { wtWebGraphThermoBaroGraphicsBase 6 } -- wtWebGraphThermoBaroGraphicsSelect Group ---------------------------- wtWebGraphThermoBaroGraphicsSelectDisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Die hier ausgewählten Sensoren werden grafisch angezeigt: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3-7: ungenutzt" ::= { wtWebGraphThermoBaroGraphicsSelect 1 } wtWebGraphThermoBaroGraphicsSelectDisplayShowExtrem OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Die Anzeige von Minima und Maxima der hier ausgewählten Sensoren wird freigeschaltet: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3-7: ungenutzt" ::= { wtWebGraphThermoBaroGraphicsSelect 2 } -- Graph Sensor Color Table wtWebGraphThermoBaroSensorColorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphThermoBaroSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste der Sensorfarben in der grafischen Darstellung." ::= { wtWebGraphThermoBaroGraphicsSelect 3 } wtWebGraphThermoBaroSensorColorEntry OBJECT-TYPE SYNTAX WtWebGraphThermoBaroSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Nummern der Sensoren." INDEX { wtWebGraphThermoBaroSensorNo } ::= { wtWebGraphThermoBaroSensorColorTable 1 } wtWebGraphThermoBaroSensorColorEntry ::= SEQUENCE { wtWebGraphThermoBaroGraphicsSensorColor OCTET STRING, wtWebGraphThermoBaroGraphicsSelectScale OCTET STRING } wtWebGraphThermoBaroGraphicsSensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Farbe des Sensors in der grafischen Darstellung." ::= { wtWebGraphThermoBaroSensorColorEntry 1 } wtWebGraphThermoBaroGraphicsSelectScale OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Zuweisung einer Skalierung zu einem Sensor: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2 : Use Scale 3 Bit 3-7: ungenutzt" ::= { wtWebGraphThermoBaroSensorColorEntry 2 } -- wtWebGraphThermoBaroGraphicsScale Group ---------------------------- wtWebGraphThermoBaroGraphicsScaleAutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Wählt den Auto Scale Modus für die jeweilige Skalierung aus: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2 : Scale 3 Auto scale enable Bit 3-7: ungenutzt" ::= { wtWebGraphThermoBaroGraphicsScale 1 } wtWebGraphThermoBaroGraphicsScaleAutoFitEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Wählt den Auto Fit Modus für die jeweilige Skalierung aus: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2 : Scale 3 Auto fit enable Bit 3-7: ungenutzt" ::= { wtWebGraphThermoBaroGraphicsScale 2 } wtWebGraphThermoBaroGraphicsScale1Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 1: Minimum." ::= { wtWebGraphThermoBaroGraphicsScale 3 } wtWebGraphThermoBaroGraphicsScale2Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 2: Minimum." ::= { wtWebGraphThermoBaroGraphicsScale 4 } wtWebGraphThermoBaroGraphicsScale3Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 3: Minimum." ::= { wtWebGraphThermoBaroGraphicsScale 5 } wtWebGraphThermoBaroGraphicsScale4Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 4: Minimum." ::= { wtWebGraphThermoBaroGraphicsScale 6 } wtWebGraphThermoBaroGraphicsScale1Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 1: Maximum." ::= { wtWebGraphThermoBaroGraphicsScale 7 } wtWebGraphThermoBaroGraphicsScale2Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 2: Maximum." ::= { wtWebGraphThermoBaroGraphicsScale 8 } wtWebGraphThermoBaroGraphicsScale3Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 3: Maximum." ::= { wtWebGraphThermoBaroGraphicsScale 9 } wtWebGraphThermoBaroGraphicsScale4Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 4: Maximum." ::= { wtWebGraphThermoBaroGraphicsScale 10 } wtWebGraphThermoBaroGraphicsScale1Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 1: Einheit." ::= { wtWebGraphThermoBaroGraphicsScale 11 } wtWebGraphThermoBaroGraphicsScale2Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 2: Einheit." ::= { wtWebGraphThermoBaroGraphicsScale 12 } wtWebGraphThermoBaroGraphicsScale3Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 3: Einheit." ::= { wtWebGraphThermoBaroGraphicsScale 13 } wtWebGraphThermoBaroGraphicsScale4Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 4: Einheit." ::= { wtWebGraphThermoBaroGraphicsScale 14 } -- wtWebGraphThermoBaroPorts Group ---------------------------- -- Table wtWebGraphThermoBaroPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphThermoBaroPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste der Einstellungen abhängig von der Sensornummer." ::= { wtWebGraphThermoBaroPorts 1 } wtWebGraphThermoBaroPortEntry OBJECT-TYPE SYNTAX WtWebGraphThermoBaroPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sensor-Parameter der einzelnen Sensoren." INDEX { wtWebGraphThermoBaroSensorNo } ::= { wtWebGraphThermoBaroPortTable 1 } WtWebGraphThermoBaroPortEntry ::= SEQUENCE { wtWebGraphThermoBaroPortName OCTET STRING, wtWebGraphThermoBaroPortText OCTET STRING, wtWebGraphThermoBaroPortOffset1 OCTET STRING, wtWebGraphThermoBaroPortTemperature1 OCTET STRING, wtWebGraphThermoBaroPortOffset2 OCTET STRING, wtWebGraphThermoBaroPortTemperature2 OCTET STRING, wtWebGraphThermoBaroPortComment OCTET STRING, wtWebGraphThermoBaroPortSensorSelect OCTET STRING } wtWebGraphThermoBaroPortName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name des Sensors." ::= { wtWebGraphThermoBaroPortEntry 1 } wtWebGraphThermoBaroPortText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Beschreibung des Sensors." ::= { wtWebGraphThermoBaroPortEntry 2 } wtWebGraphThermoBaroPortOffset1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 1." ::= { wtWebGraphThermoBaroPortEntry 3 } wtWebGraphThermoBaroPortTemperature1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset-Kalibrierung: Referenztemperatur 1 in Grad mit max. 2 Nachkommastellen." ::= { wtWebGraphThermoBaroPortEntry 4 } wtWebGraphThermoBaroPortOffset2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 2." ::= { wtWebGraphThermoBaroPortEntry 5 } wtWebGraphThermoBaroPortTemperature2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset-Kalibrierung: Referenztemperatur 2 in Grad mit max. 2 Nachkommastellen." ::= { wtWebGraphThermoBaroPortEntry 6 } wtWebGraphThermoBaroPortComment OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset-Kalibrierung: Angaben zu Datum, Referenzgerät, Operator." ::= { wtWebGraphThermoBaroPortEntry 7 } wtWebGraphThermoBaroPortAltidude OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Höhe des Sensors über Meereshöhe (üNN)." ::= { wtWebGraphThermoBaroPorts 2 } -- wtWebGraphThermoBaroManufact Group ---------------------------- wtWebGraphThermoBaroMfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Hersteller Firmenname" ::= { wtWebGraphThermoBaroManufact 1 } wtWebGraphThermoBaroMfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Adresse des Herstellers." ::= { wtWebGraphThermoBaroManufact 2 } wtWebGraphThermoBaroMfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Hotline des Herstellers." ::= { wtWebGraphThermoBaroManufact 3 } wtWebGraphThermoBaroMfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Internet-Adresse des Herstellers." ::= { wtWebGraphThermoBaroManufact 4 } wtWebGraphThermoBaroMfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Gerätebezeichnung (Typ) des Herstellers." ::= { wtWebGraphThermoBaroManufact 5 } wtWebGraphThermoBaroMfOrderNo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bestellnummer des Gerätes des Herstellers." ::= { wtWebGraphThermoBaroManufact 6 } -- wtWebGraphThermoBaroDiag Group ---------------------------- wtWebGraphThermoBaroDiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Anzahl der Einträge im Fehlerspeicher." ::= { wtWebGraphThermoBaroDiag 1 } wtWebGraphThermoBaroDiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Bitweise kodierte Fehlerursachen." ::= { wtWebGraphThermoBaroDiag 2 } wtWebGraphThermoBaroDiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Der Wert dieser Variable wird als Index für die Ausgabe eines Fehlertextes (wtWebGraphThermoBaroDiagErrorMessage) verwendet. Die Fehler im Speicher sind von 1 bis wtWebGraphThermoBaroDiagErrorCount durchnummeriert. Nach dem Schreiben einens gültigen Wertes in diese Variable kann der dazugehörige Text in wtWebGraphThermoBaroDiagErrorMessage ausgelesen werden." ::= { wtWebGraphThermoBaroDiag 3 } wtWebGraphThermoBaroDiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Abhängig vom Wert wtWebGraphThermoBaroDiagErrorIndex wird ein Fehlertext angezeigt." ::= { wtWebGraphThermoBaroDiag 4 } wtWebGraphThermoBaroDiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Durch Schreiben eine 1 in diese Variable, wird der Fehlerspeicher gelöscht." ::= { wtWebGraphThermoBaroDiag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebGraphThermoBaroAlert1 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 31 wtWebGraphThermoBaroAlert2 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 32 wtWebGraphThermoBaroAlert3 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 33 wtWebGraphThermoBaroAlert4 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 34 wtWebGraphThermoBaroAlert5 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 35 wtWebGraphThermoBaroAlert6 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 36 wtWebGraphThermoBaroAlert7 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 37 wtWebGraphThermoBaroAlert8 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 38 wtWebGraphThermoBaroAlert9 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 91 wtWebGraphThermoBaroAlert10 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 92 wtWebGraphThermoBaroAlert11 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 93 wtWebGraphThermoBaroAlert12 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 94 wtWebGraphThermoBaroAlert13 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 95 wtWebGraphThermoBaroAlert14 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 96 wtWebGraphThermoBaroAlert15 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 97 wtWebGraphThermoBaroAlert16 TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 98 wtWebGraphThermoBaroAlertDiag TRAP-TYPE ENTERPRISE wtWebGraphThermoBaro VARIABLES { wtWebGraphThermoBaroDiagErrorIndex, wtWebGraphThermoBaroDiagErrorMessage } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn eine Diagnose/Error-Message ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 END