3.4
2018-08-17T16:48:20Z
UPS
Template APC Smart-UPS
Template APC Smart-UPS
UPS
Battery
Diagnostics
Info
Input
Output
Test
-
APC Battery Capacity
1
public
.1.3.6.1.4.1.318.1.1.1.2.2.1.0
apc_battery.capacity
30s
90d
365d
0
3
%
0
0
0
0
0
Battery
-
APC Battery Replace Indicator
1
public
.1.3.6.1.4.1.318.1.1.1.2.2.4.0
apc_battery.replaceIndicator
30s
90d
365d
0
3
0
0
0
0
0
Battery
APC Battery Replacement Indicator
-
APC Battery Status
1
public
.1.3.6.1.4.1.318.1.1.1.2.1.1.0
apc_battery.status
30s
90d
365d
0
3
0
0
0
0
0
Battery
APC Battery Status
-
APC Battery Temperature
1
public
.1.3.6.1.4.1.318.1.1.1.2.2.2.0
apc_battery.temperature
30s
90d
365d
0
3
°C
0
0
0
0
0
Battery
-
APC Time on Battery
1
public
.1.3.6.1.4.1.318.1.1.1.2.1.2.0
apc_battery.time
30s
90d
365d
0
0
uptime
0
0
0
0
0
Battery
1
0.01
-
APC Time on Battery remaining
1
public
.1.3.6.1.4.1.318.1.1.1.2.2.3.0
apc_battery.time.remaining
30s
90d
365d
0
0
s
0
0
0
0
0
Battery
1
0.01
-
APC Battery Voltage
1
public
.1.3.6.1.4.1.318.1.1.1.2.2.8.0
apc_battery.voltage
30s
90d
365d
0
3
Volts
0
0
0
0
0
Battery
-
Test Last Diagnostics Date
1
public
.1.3.6.1.4.1.318.1.1.1.7.2.4.0
apc_diagnostics.testDate
30s
90d
0
0
1
0
0
0
0
0
Diagnostics
-
Test Last Diagnostics Results
1
public
.1.3.6.1.4.1.318.1.1.1.7.2.3.0
apc_diagnostics.testResults
30s
90d
365d
0
3
0
0
0
0
0
Diagnostics
APC Diagnostic Result
-
APC Firmware Revision
1
public
.1.3.6.1.4.1.318.1.1.1.1.2.1.0
apc_firmware
60s
90d
0
0
1
0
0
0
0
0
Info
-
APC Input Frequency
1
public
.1.3.6.1.4.1.318.1.1.1.3.2.4.0
apc_input.frequency
30s
90d
365d
0
3
Hz
0
0
0
0
0
Input
-
APC Input Phase
1
public
.1.3.6.1.4.1.318.1.1.1.3.1.1.0
apc_input.phase
30s
90d
365d
0
3
0
0
0
0
0
Input
-
APC Input Voltage
1
public
.1.3.6.1.4.1.318.1.1.1.3.2.1.0
apc_input.volt
30s
90d
365d
0
0
Volts
0
0
0
0
0
Input
-
APC Modell
1
public
.1.3.6.1.4.1.318.1.1.1.1.1.1.0
apc_model
60s
90d
0
0
1
0
0
0
0
Modell der APC
0
Info
-
APC Output Current (Amperes)
1
public
.1.3.6.1.4.1.318.1.1.1.4.2.4.0
apc_output.amperes
30s
90d
365d
0
3
Amperes
0
0
0
0
0
Output
-
APC Output Frequency
1
public
.1.3.6.1.4.1.318.1.1.1.4.2.2.0
apc_output.frequency
30s
90d
365d
0
3
Hz
0
0
0
0
0
Output
-
APC Output Load
1
public
.1.3.6.1.4.1.318.1.1.1.4.2.3.0
apc_output.load
30s
90d
365d
0
3
%
0
0
0
0
0
Output
-
APC Output Phase
1
public
.1.3.6.1.4.1.318.1.1.1.4.1.2.0
apc_output.phase
30s
90d
365d
0
3
0
0
0
0
0
Output
-
APC Output Status (basic)
1
public
.1.3.6.1.4.1.318.1.1.1.4.1.1.0
apc_output.status.basic
30s
90d
365d
0
3
0
0
0
0
0
Output
APC Basic Output Status
-
APC Output Voltage
1
public
.1.3.6.1.4.1.318.1.1.1.4.2.1.0
apc_output.volt
30s
90d
365d
0
0
Volts
0
0
0
0
0
Output
-
APC Serial Number
1
public
.1.3.6.1.4.1.318.1.1.1.1.2.3.0
apc_serial
60s
90d
0
0
1
0
0
0
0
0
Info
{Template APC Smart-UPS:apc_battery.replaceIndicator.last()}=2
0
Battery should be replaced
0
0
3
Please get a new Battery and replace it as soon as possible!
0
0
{Template APC Smart-UPS:apc_input.frequency.last()}<>50
0
Frequency is not 50 Hz
0
0
1
0
0
{Template APC Smart-UPS:apc_input.frequency.last()}>52
0
Input Fequency to high
0
0
3
0
0
{Template APC Smart-UPS:apc_input.frequency.last()}<48
0
Input Fequency to low
0
0
3
0
0
{Template APC Smart-UPS:apc_output.load.last()}>80
0
Load on this APC unit is to high
0
0
2
The load on this unit is too high. Buy a stronger unit or decrease the number of devices on this UPC.
0
0
{Template APC Smart-UPS:apc_input.phase.last()}<1
0
No Power Source
0
0
4
The APC lost its power source.
0
0
{Template APC Smart-UPS:apc_battery.time.remaining.last()}<5m
0
Remaining Time on Battery is lower than 5 Minutes
0
0
5
0
0
{Template APC Smart-UPS:apc_diagnostics.testResults.last()}=2
0
Test Failed
0
0
3
The diagnostic Test failed.
0
0
{Template APC Smart-UPS:apc_battery.capacity.last()}<10
1
{Template APC Smart-UPS:apc_battery.capacity.last()}>10
UPS Capacity lower than 10 Percent
0
0
5
The Battery Capacity is lower than 10%. Check the Power source.
0
0
{Template APC Smart-UPS:apc_battery.capacity.last()}<20
1
{Template APC Smart-UPS:apc_battery.capacity.last()}>20
UPS Capacity lower than 20 Percent
0
0
4
The Battery Capacity is lower than 20%. Check the Power source.
0
0
{Template APC Smart-UPS:apc_battery.capacity.last()}<30
1
{Template APC Smart-UPS:apc_battery.capacity.last()}>30
UPS Capacity lower than 30 Percent
0
0
3
The Battery Capacity is lower than 30%. Check the Power source.
0
0
{Template APC Smart-UPS:apc_battery.capacity.last()}<50
1
{Template APC Smart-UPS:apc_battery.capacity.last()}>50
UPS Capacity lower than 50 Percent
0
0
3
The Battery Capacity is lower than 50%. Check the Power source.
0
0
{Template APC Smart-UPS:apc_battery.capacity.last()}<50
1
{Template APC Smart-UPS:apc_battery.capacity.last()}>70
UPS Capacity lower than 70 Percent
0
0
2
The Battery Capacity is lower than 70%. Check the Power source.
0
0
{Template APC Smart-UPS:apc_battery.capacity.last()}<90
1
{Template APC Smart-UPS:apc_battery.capacity.last()}>90
UPS Capacity lower than 90 Percent
0
0
1
The Battery Capacity is lower than 90%. Run Diagnostics.
0
0
Frequency
900
200
0.0000
100.0000
1
1
0
1
0
0.0000
0.0000
0
0
0
0
0
0
1A7C11
0
2
0
-
Template APC Smart-UPS
apc_input.frequency
1
0
F63100
0
2
0
-
Template APC Smart-UPS
apc_output.frequency
APC Basic Output Status
1
unknown
2
onLine
3
onBattery
4
onSmartBoost
5
timedSleeping
6
softwareBypass
7
off
8
rebooting
9
switchedBypass
10
hardwareFailureBypass
11
sleepingUntilPowerReturn
12
onSmartTrim
13
ecoMode
14
hotStandby
15
onBatteryTest
16
emergencyStaticBypass
17
staticBypassStandby
18
powerSavingMode
19
spotMode
20
eConversion
21
chargerSpotmode
22
inverterSpotmode
APC Battery Replacement Indicator
1
noBatteryNeedsReplacing
2
batteryNeedsReplacing
APC Battery Status
1
unknown
2
batteryNormal
3
batteryLow
APC Diagnostic Result
1
ok
2
failed
3
invalidTest
4
testInProgress